Loading...
HomeMy WebLinkAbout2704 PALMETTO DR; ; CBR2022-0102; PermitBuilding Permit Finaled Residential Permit Print Date: 10/17/2022 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: 2704 PALMETTO DR, CARLSBAD, CA 92009-3081 BLDG-Residential Work Class: 2131801500 Track#: $25,425.00 Lot#: Project#: Plan#: Addition Bedrooms: Bathrooms: Construction Type:V-B Orig. Plan Check #: Occupant Load: Plan Check#: Code Edition: Sprinkled: Project Title: Description: 2704 PALMITTO; NEW BEDROOM (170 SF) ADDITION, (SO SF) BATHROOM REMODEL Applicant: NEST CONSTRUCTION NEVILLE ROSEMAN 1611 S MELROSE DR, # A-287 VISTA, CA 92081-5407 (760) 616-9636 FEE BUILDING PLAN CHECK BUILDING PLAN REVIEW -M INOR PROJECTS (LDE) BUILDING PLAN REVIEW -MINOR PROJECTS (PLN) REMODEL-RESIDENTIAL-OTHER SB1473 -GREEN BUILDING STATE STANDARDS FEE SFD & DUPLEXES STRONG MOTION -RESIDENTIAL (SMIP) Total Fees: $3,008.26 Total Payments To Date: $3,008.26 (city of Carlsbad Permit No: CBR2022-0102 Status: Closed -Fina led Applied: 01/11/2022 Issued: 05/10/2022 Fina led Close Out: 10/17/2022 Final Inspection: 09/29/2022 INSPECTOR: Renfro, Chris Balance Due: Alvarado, Tony AMOUNT $1,067.95 $194.00 $98.00 $481.00 $2.00 $1,162.00 $3.31 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other simi lar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov {_ Cicyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check <!.'&P,..'2oZ:1.. J O\Ool- Est. Value .ij 3f , l'f O. sP PC Deposit Date l -il -21)~ Job Address 2704 PALMETTO DRIVE. CARLSBAD 92009 Suite:. ____ APN: 213-180-15-00 CT/Project#: CT# 02-14 BRESSI RANCH -UNIT 6 Lot #: LOT #439, Year Built: ..:2;..::0;..::0;..::5;__ _____ _ Fire Sprinklers: 0YES{!) NO Air Conditioning:0 YES ONO Electrical Panel Upgrade: QvEs0 NO BRIEF DESCRIPTION OF WORK: 170 SF enc o&u, e of exist 119 patio and conversion to interior space Bathrnom remodel (j] Addition/New: HO Living SF, 0 Deck SF, 0 Patio SF, 0 Garage SF _o __ Is this to credt<' an Accessory Dwelling Unit? O Y 0 N New Fireplace? 0 Y 0 N, if yes how many? __ (i]Remodel: 50 0 Pool/Spa: _ SF of affected area Is the area a conversion or change of use? Ov 0N ___ SF Additional Gas or Electrical Features? ___________ _ osolar: ___ KW, ___ Modules, Mounted: 0Roof 0Ground, Tilt: 0 YON, RMA: Ov ON, Battery Ov ON, Panel Upgrade: Ov ON 0 Reroof: -----------------------------------□ Plumbing/Mechanical/Electrical 0 Only: Other: This permit is to be issued in the name of the Property Owner as Owner-Builder, licensed contractor or Authorized Agent of the owner or contractor. The person //sted as the Appltcant below w,/1 be the main point of contact throughout the permit process. PROPERTY OWNER APPLICANT [j PROPERTY OWNERS AUTHORIZED AGENT APPLICANT 0 Name: MANISH AND NEHA SINGH Name: ___________________ _ Address: 2716 PALMETTO DRIVE Address: __________________ _ City: CARLSBAD State: CA Zip: 92009 City: _________ State: ___ Zip: ____ _ Phone: (442) 244-0664 Email: MANISHSINGH08@HOTMAIL.COM Phone: __________________ _ Email: __________________ _ DESIGN PROFESSIONAL APPLICANT O CONTRACTOR OF RECORD APPLICANT 0 Name:_ CHRISTOPHER ROADES ___ Name: NEST CONSTRUCTION & SERVICES, INC. Address: 2749 E 2ND STREET Address: 1611 S. ,ELROSE DR, Ste. A #287 City: LONG BEACH State: CA Zip:_9_os_o_3 __ City: VISTA State:._C_A __ Zip: 92081 Phone: 949-355-9702 Email: -ARCHCSR@GMAIL.COM Phone: 760.616.9636 Email: nev@nestconstructionservices.com Architect State license: _c_2_s3_3_3 _______ _ State License/class: 1025849 Bus. license: ---- ,&35 raradav Ave Carlsb~d. CA 92008 Ph: 760-602 2719 Fax: 760·602·8558 REV 08/20 - ----- IDENTIFY WHO WILL PERFORM THE WORK BY COMPLETING (OPTION A) OR (OPTION B) BELOW: (OPTION A): PCENSED CONTRACTOR DECLARATION: rn,•by aJl1rn' und,•1 J;<'nalcy of pefJu1y ;;;;t ~,~ed under prov1>•ons of Chapter 9 (rommc11c1ng with 5£•ct,on 7000) of D1V111on 3 ot lilt 8:1\ir>•'H and PioJt rnam Codt>, and my '1ccme 1s ,n full /otcl.' and effect I also of/11m undn pl'nolty of per;ury one 01 the folio ,v,nq dcclnrotton~ D J •· ,~d" 1 rnJ nlJ'll I CPr t.f,cJtl' of tOn\1 nt lo Sl' I 1nwfl' for wo•l.~is col"l'prn1at,o~ p•o,drd by Srct1on 3700 ol thl' l,1bo1 (odl' lor thf' pp·fcrmanci• of thr .., " v.h '11h11, '"' t 11s,u d Polory No D I._ JrJ ,, ,n ,,r:.1 r v.cr~l'r's comprn,,1:10~. JS rPqv,red by ~ect on 3700 ol the l~bor Code for the pprformJntc of tt>e wo•k fo· wh,,t> th·s pe1m,t " l>l~td '1, "' ,k,' ' mpPn1 .. t "" nsurJntP tJrnN Jrd policy n~mber are Insurance Company Name: _____________________ _ Policy No ________________ _ _______ Expiration Date: ______ _ D C~rt I c.1•, c• fw, mpt,or I ten tv that 1n lhe performance of the work for which this permit ,s rssued I shall not employ any per,on 1n •nv mannrr >O JS to b,•com~ ub1," lo 11 ' .,o,,e·, co,.,p<'ll\dt.on Law, of Ca 1fornia WARNING· Failure to secure workers compensation coverage 1s unlawful and shall subject an employer to mm,nal pen.ilt1es dnd c,v1I fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for 1n Sectfon 3706 of the Labor Code, ,nttrest and attorney's foes CONSTRUCT 01\J L~IN§_AGFNCY, IF ANY: r neie:rr •!fur-t 11 ther<> 1 · a con\lruct on lend ng agency for the performdnci-of the work tl11> perm,t ,s ,ssued (Sec 3097 (1) C,v I Cod<•) Lender's Ndme __ ___ ____ _ __ Lender's Address: ____________ _ CONTRACTOR PRINT: SIGN: DATE: ------------------------- (OPTION B) OWNER~ER DECLARATION: I hereby ah,rm thar I am exempt from Contractor's Lteense Law for the follaw,ng reason: 0 1 J> o .. rer ~ :~, property o• my Pmpio1ees w,tn wJges as their sole compen,at,on, will do the work and the structure II not intended or offerrd lor sdlr (~~: l:JH Bu<is, s, •~:l ro1,,, ->n, ~ode The ContrJctor', L,cr nw Law does not apply to •n owner or properly who bu1'ds or unprovcs thereon Jlld ""ho doe, scch ..,o,, ~,.,, P f 01 tl"o ;t, ► • o,•.n Pmployceo, pro.1ded that such improvements a,e not intended or offered for sale If, however, tne building or ,mp,ovl'mPnt I\ so-d w Inn on,• 1~•r of comp H 1~ t~• ownPr bu, dN wilt have t~P burden of proving thdt he did not build or ,mprove for the purpose of sate) (!]1 as owner ol tnr p•op,•rty, am c,clus,vely contracting with l1temed contractors to construct thP proiect (Sec 7044, Business and Prolernons Code The Cortracto, , t1te•· ,1• Law dOt'> not app,y to an owner of property who builds or 11nprovr1 the1eon, and contracts tor such proJC'Cts with contra(lo•b l I n•nst>d porsuant 10 ,~~ Mtra<tor', License Law) 0 I am exempt und.,, 8u11nP<> and P1ofess,on1 Code D1v1s1on 3, Chapter 9 Article 3 for th s reason D •owner Builder acknowledgement and verification form" has been filled out, ,,gncd and Jlt•Ch('d to this appl1CJt1on. 0 Owners "Authomed Agent Form" has been filled out, signed and dttd,hPd to !hrs apphcat,on qi,,nq c/le agent ouc/Jorrcy lo obco,n I/IP pprm,c "" thP o.wrrr , on,a,J B, my s,gnatJ·e below ac~nowlcdge that, PxrPpt for mv pPrsonal residence in which I must have resided for at least OM' yPa, prior to compf~11011 of t'1c mproaement\ ro,ered by th,1 pprm,t, I cannot legally sell a structure that I have bullt as an owner builder 1f ,t hds not been constructed n ,11 r nt1rnty by l1rl'r\1-d cnntrMtors I understand that o cooy of the opohcable Jaw Sl'Won 7044 of tile Bu1,nPH ond Prafess,ons CodP, 11 ovo,loolP upon request when I'>,> app/•cat•on ,s ,ubrr1CCl'd or at the fo//o.,,,nq Wt>b 11CP http //www Jegrnfo co gov/ca/ow html SIGN: -l~~ ._;____.-;;;;,..·'-'J ______ DATE: OWNER PRINT: .... M--:..:..Aa;...N_.;.l_,_'.).;..._H____...$.._1 ..... N.;;;;+~-'-t{.....___ ·7 0 I / 0 {., he. 2 2.. F I APPLICANT CERTIFICATION: SIGNATURE REQUIRED AT THE TIME OF SUBMITTAL By my signature bPtow, I certify thor I om the property owner or Store of Col,forn,o l,censed Conrrartor or authonzed to act on thr proprrt y ownl'r or controctor's behalf I certify that I hovP read the opplicot1on and stotP that the obovr mformot1on ,s correct ond thot thP information on tlie plans 1s accurate I agree to comply w,th all Crty ord,nonces ond State lows relating to bu1/d1ng construct,on , l>ereby outho,,ze reprrsentotive of thl' Ctty of Carlsbad to enter upon the above ml!ntroned property for inspection purposes I A~O AGREE ro SAV[ INOtMN/1-Y ANO Kff P HARMLESS Tl-IE (I TY OF CARLSBAD AGAINST All LIAB!UTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY AU RUf AGAII\/STSA/O CITY IN rONSEQufN([ or TH[ GRANTING or THIS PERMIT. OSHA; An OSHA perm,t IS required for excovot1ons OVl'f 5'0' deep 0'1d dPmol,t,on or conscructwn of structurPs over 3 stones m height APPLICANT PRINT: ...:.M....;..;.'1~1\J.;.;l:..:S:..:.n.l....-....;S:;.;1-'-rJ...;<:;,._'1...___ SIGN: _ .... t\.,.., __ ;{+------DATE: 0 I ( f) b p v2. ""2. HdS Fardddy AvP C drhb~d CA '12008 Ph 760 602-2719 Fax• 760 602 8558 Email Bu ldtng@c.irltb•dca~ 2 REV 08/20 (_ City of Carlsbad • OWNER-BUILDER ACKNOWLEDGEMENT FORM B-61 Development Services Building Division 1635 Faraday Avenue 760 602 2719 www.carlsbadca.gov OWNER-BUILDER ACKNOWLEDGMENT FORM Pursuant to State of California Health and Safety Code Section 19825-19829 To: Property Owner An <1pphc.it1on for construction perm1t(s) has been submitted in your name listing you as the owner builder of the propPr t I I orated at. S1tP Address 2704 PALMETTO DRIVE, CARLSBAD, CA, 92009 The ( ty of Carlsbad ("City") is providing you with this Owner-Builder Acknowledgment and Venf1cat1on form to inform you of the responsib1ht1es and the possible risks associated with typical construction act1vit1es issued in your n;ime as the Owner-Builder. The City will not issue a construction permit until you have read and Initialed your understanding of each provision 1n the Property Owner Acknowledgment section below and sign the form. An agent of the owner cannot execute this notice unless you, the property owner, complete the Owner's Authorized Agent form and it is accepted by the City of Carlsbad. INSTRUCTIONS: Please read and initial each statement below to acknowledge your understanding and venf1cat1on of this information by signature at the bottom of the form. These are very Important construction related acknowledgments designed to inform the property owner of his/her obligations related to the requested permit activities. I. ~I understand a frequent practice of unlicensed contractors Is to have the property owner obtain an "Owner Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any iniurles sustained by an unlicensed contractor and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. II. .J~ .. 2. .. _I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed contractor to assume this responsibility. Ill. 'r') I understand as an "Owner Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed 1n his or her name instead of my own. IV. ~) I understand contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. V .ttJ_r understand if I employ or otherwise engage any persons, other than California licensed contractors, and the total value of my construction is at least five hundred dollars ($500), Including labor and materials, f may be considered an "employer" under state and federal law. 1 REV. 08/20 - OwnPr Builder Acknowledgement Contmued VI VI VII IX X. XI XII r~ I _'_1 undl'rstand f I .im considrred an "employer" under state and federal law , I mu~t register with t he stc1te and f,•dP1 JI government, withhold payroll taxes, provide workers' compensation disability ImurancP, and contr1but1 to unc>rnp,oyment compemation for each "employee " I also understand my failure to abide by these ,Jv. 'T'lcly subiect me to serious financial risk fV'; I u·1derstand under California Contractors' State License Law, an Owner Builder who builds single family re)1dent1..il structures cannot legally build them with the intent to offer them for sale, unless all work 1s performed by licensed subcontractors and the number of structures does not exceed four w1th1n any calendar yedf, or all of the work 1s performed under contract with a licensed general building contractor. ~ undPrStdnd as an Owner Builder 1f I sell the property for wh,ch this permit Is issued, I may be held liable for ilny finc1nc1al or personal iniuries sustained by any subsequent owner(s) which result from any lc1tent construction defects in the workmanship or materials l'V"{ I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Admin1strat1on, the California Departml'nl of Benefit Payment\, .ind the California DIvis1on of Industrial Accidents. I also understand I may contact the Cal1forn1a Contr.Jctors' Stc1te L1Cense Board (CSLB) at 1 800-321-CSLB (2752) or www cslb ca gov for more informat ion about 1censed contractors fV'~ I am aware of and consent to an Owner Builder building permit applied for in my name, and understand thc1t I dm the party legally and financially responsible for proposed construction actIvIty at the following address· \\" ~I agrf'P that, as the party legally and financially responsible for t his proposed construction activity, I will abide by all applicable laws and requIremrnts that govern Owner Builders dS well as employers fV') I agree to notify the issuer of this form immediately of any add1t1ons, deletions, or changes to any of the informat ion I have provided on this form Licensed contractors are regulated by laws designed to protect the public. If you contract with someone w ho does not have a license, the Contractor's State License Board may be unable to assist you w ,th any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may br In CIVIi court It Is also important for you to understand that if an unlicensed Cont ractor or employee of that 1nd1v1dual or firm 1s iniured while working on your property, you may be held liable for damages. If you obtain a permit as Owner But!der and w ish to hire contractors, you w ill be responsible for verifying whether or not those contractors are propNly licensed and t he st atus of thei r workers' compensa tion coverage. Before o bw/d,ng permit con be issued, this f orm must be completed, signed by the property owner and returned to the City of Carlsbad But/ding Division. I derlarl' unde, pena•ry of pn;ury that I have read and understand all of Che 1nfarmat1on provided on this form and thot my 1esponses ,nc1~d•nq my ourhoflcy to s,qn this form, t.) truf! ond correcr I om aware that I hove the opc,on to consult wjth legal counsel pnor to 1uqn1n9 ems form, ona I hove e,cher / 1) consJ/trd w,t~ /pqof counsel pnor lo i,qn,ng this form or /2) hove wo,ved th,i r1qh1 m ,,qn,ng chi, form .v,thout 1hP odv•<e of •ego• coun,rl P1 P./\J IS rL ( /Iv~ vj_ Propert y Owner Name (PR INT} vW Prope4wner Signature orjo6/z (,;l,. 2 Date 2 REV 08/20 (_ Cicyof Carlsbad OWNERS AUTHORIZED AGENT FORM 8-62 Development Services Building Division 1635 Fc1raday Avenue 160 602 2719 www CdrbbtldCd gov OWNER'S AUTHORIZED AGENT FORM Only a property owner, contractor or the,r authorized agent moy submit plans and applicot,ons for bu,ldmg Pt'rrn,t~ To authorize a third party agent ro sign for a building permit, the owner's third party agent must bring this signed form, which 1den11/1es the agent and the owner who s/he ,s representing, and for what Jobs s/he may nbro,n permits. Th e form must be completed in its ent,rety 10 be accept Pd by the Ctty for each separate pPrm,t oppl1cat1on Note: The following Owner's Authorized Agent form is required to be completed by the property owner only when designating an agent to apply for a construction permit on his/her behalf. AUTH_DRIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Property Owner Acknowledgement, the execution of which I understand 1s my personal respons1b1l1ty, I hNt>by authorize the following perrnn(s) to act as my agent(s) to apply for, sign, and file the documrnts nt>ces~ary to obtain an Owner-Builder Permit for my proJect. Scope of Construction Project (or Description of Work): __________ _ 2704 Palmetto Drive, Carlsbad 92009 Pro1ect Loca tion or Address ____________________________ _ Neville Roseman 760.616.9636 Name of Authorized Agent· _________________ Tel No. ___ _ Address of Authorized Agent: NEST Construction Services, Inc 1611 S. Melrose Drive., Suite A #287 Vista CA 92081 I declare under penalty of per1ury that I am the property owner for the address listed above and I per~onally filled out the above information and certify ,ts accuracy. Property Owner's Signature: ___ .,_~L ........ ;lc_' ______________ Date: _0_1.,..)_o_t_-/.__Lo_2...1-__ PERMIT INSPECTION HISTORY for (CBR2022-0102) Permit Type: BLDG-Residential Application Date: 01/11/2022 Owner: CO-OWNERS SIN GH MANISH KAND NEHA Work Class: Addition Issue Date: 05/10/2022 Subdivision: CARLSBAD TCT#02-14 BRESSI Status: Scheduled Date 08/19/2022 08/22/2022 09/29/2022 Closed -Finaled Expiration Date: 02/21/2023 IVR Number: 38045 RANCH UNIT#06 Address: 2704 PALMETTO DR CARLSBAD, CA 92009-3081 Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection Status Checklist Item COMMENTS BLDG-Building Deficiency August 16, 2022: 08/19/2022 BLDG-16 Insulation Checklist Item 1. existing, first floor location-half bathroom remodel, to create full bathroom with shower stall.. 2. Underground plumbing, wrapped plumbing waste lines in trench-approved. 3. Rough combination, framing, plumbing insulated and wrapped, electrical, and mechanical, scope of work per plan-approved. 189557-2022 COMMENTS Passed Chris Renfro BLDG-Building Deficiency BLDG-27 Shower Pan/Tubs Checklist Item 189556-2022 COMMENTS Passed Chris Renfro BLDG-Building Deficiency 08/22/2022 BLDG-17 Interior Lath/Drywall Checklist Item 189646-2022 Partial Pass Tony Alvarado COMMENTS BLDG-Building Deficiency August 22, 2022: (Partial Pass). 09/29/2022 BLDG-Final Inspection Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 1. Drywall/Gypsum Board anchoring/fastening at entry way location-patchwork, new addition infill courtyard den areas, and partial new full bath under stairs bathroom remodel area - approved. 192956-2022 COMMENTS Passed Tony Alvarado Passed Yes Complete Passed Yes Complete Passed Yes Reinspection Incomplete Passed Yes Passed Yes Yes Yes Yes Complete Monday, October 17, 2022 Page 4 of 4 PERMIT INSPECTION HISTORY for (CBR2022-0102) Permit Type: BLDG-Residential Application Date: 01/11/2022 Owner: CO-OWNERS SINGH MANISH KAND NEHA Work Class: Addition Issue Date: 05/10/2022 Subdivision: CARLSBAD TCT#02-14 BRESSI Status: Closed -Finaled Expiration Date: 02/21/2023 IVR Number: 38045 RANCH UNIT#06 Address: 2704 PALM ETTO DR CARLSBAD, CA 92009-3081 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Monday, October 17, 2022 Checklist Item BLDG-Building Deficiency COMMENTS August 16, 2022: 1. existing, first floor location-half bathroom remodel, to create full bathroom with shower stall .. 2. Underground plumbing, wrapped plumbing waste lines in trench-approved. 3. Rough combination, framing, plumbing insulated and wrapped, electrical, and mechanical, scope of work per plan-approved. BLDG-24 Rough/Topout 189395-2022 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS August 16, 2022: 1. existing, first floor location-half bathroom remodel, to create full bathroom with shower stall .. 2. Underground plumbing, wrapped plumbing waste lines in trench-approved. 3. Rough combination, framing, plumbing insulated and wrapped, electrical, and mechanical, scope of work per plan-approved. BLDG-31 Underground/Conduit - Wiring 189396-2022 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS August 16, 2022: 1. existing, first floor location-half bathroom remodel, to create full bathroom with shower stall .. 2. Underground plumbing, wrapped plumbing waste lines in trench-approved. 3. Rough combination, framing, plumbing insulated and wrapped, electrical, and mechanical, scope of work per plan-approved. BLDG-41 Underground 189397-2022 Passed Tony Alvarado Ducts (Mech) Passed Yes Complete Passed Yes Complete Passed Yes Complete Page 3 of 4 PERMIT INSPECTION HISTORY for (CBR2022-0102) Permit Type: BLDG-Residential Application Date: 01/11/2022 Owner: CO-OWNERS SINGH MANISH KAND NEHA Work Class: Addition Issue Date: 05/10/2022 Subdivision: CARLSBAD TCT#02-14 BRESSI Status: Scheduled Date 08111/2022 08/16/2022 Closed -Finaled Expiration Date: 02/21/2023 IVR Number: 38045 RANCH UNIT#06 Address: 2704 PALMETTO DR CARLSBAD, CA 92009-3081 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS 08111/2022 BLDG-34 Rough Electrical 189012-2022 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS Rough electrical-Existing electrical circuits for new addition/infill area-approved. Rough mechanical -new infill/edition habitable space, relocate and extend mechanical ducting and register-approved. BLDG-44 Rough/Ducts/Dampers 189013-2022 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS Rough electrical-Existing electrical circuits for new addition/infill area-approved. Rough mechanical -new infill/edition habitable space, relocate and extend mechanical dueling and register-approved. 08/16/2022 BLDG-14 189394-2022 Passed Tony Alvarado Frame/Steel/Bolting/We lding (Decks) Checklist Item BLDG-Building Deficiency COMMENTS August 16, 2022: 1. existing, first floor location-half bathroom remodel, to create full bathroom with shower stall .. 2. Underground plumbing, wrapped plumbing waste lines in trench-approved. 3. Rough combination, framing, plumbing insulated and wrapped, electrical, and mechanical, scope of work per plan-approved. BLDG-21 Underground/Underflo or Plumbing 189288-2022 Passed Tony Alvarado Passed Yes Yes Yes Passed Yes Passed Yes Passed Yes Complete Complete Complete Complete Monday, October 17, 2022 Page 2 of 4 Building Permit Inspection History Finaled (city of Carlsbad Permit Type: Work Class: Status: Scheduled Date 07/14/2022 07/22/2022 07/27/2022 PERMIT INSPECTION HISTORY for (CBR2022-0102) BLDG-Residential Addition Closed -Finaled Actual Inspection Type Start Date 07/14/2022 BLDG-11 Foundation/Ftg/Piers (Rebar) Checklist Item Application Date: 01/11/2022 Issue Date: 05/10/2022 Expiration Date: 02/21/2023 IVR Number: 38045 Inspection No. Inspection Status 186825-2022 Passed COMMENTS Owner: CO-OWNERS SINGH MANISH KAND NEHA Subdivision: CARLSBAD TCT#02-1 4 BRESSI RANCH UNIT#06 Address: 2704 PALMETTO DR CARLSBAD, CA 92009-3081 Primary Inspector Reinspection Inspection Tony Alvarado Complete Passed BLDG-Building Deficiency July 14, 2022: Yes 1. New addition, two-story level, infill addition, inside existing three sided residential dwelling alcove/courtyard area. 2. Third-party deputy inspector report for Doweling steel reinforcement rebar into existing three sided bldg. perimeter footing wall locations -verified. BLDG-12 Steel/Bond Beam 186824-2022 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS July 14, 2022: 1. New addition, two-story level, infill addition, inside existing three sided residential dwelling alcove/courtyard area. 2. Third-party deputy inspector report for Doweling steel reinforcement rebar into existing three sided bldg. perimeter footing wall locations -verified. 07/22/2022 BLDG-13 Shear Panels/HD (ok to wrap) 187 441-2022 Cancelled Tony Alvarado 07/27/2022 Checklist Item COMMENTS BLDG-Building Deficiency July 22, 2022: scope of residential alteration work does not require shear wall anchoring/fastening schedule. Per engineered plans and detail specifications. BLDG-15 Roof/ReRoof 187442-2022 (Patio) BLDG-18 Exterior 187810-2022 Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency Exterior Lath BLDG-84 Rough Combo(14,24,34,44) 18797 5-2022 Passed Tony Alvarado Passed Tony Alvarado Passed Tony Alvarado Complete Passed Yes Reinspection Incomplete Passed No Complete Complete Passed Yes Complete Monday, October 17, 2022 Page 1 of 4 GB Inspections LLC (619) 981-5946 Inspection Report Project Name: _ ___..S-........i n......,g~h~R.aJe~s ........... i d...,e ............. n ..... c ...... e __ _ Page : __ of __ Report# ___ _ Project Address: ____ _27__.__....__04..____.___.Ea.1 ............... m----....ett QJ~d (.....__ Architect cii.2bxi-l Ioi frP!rMJ) Permit#: ___________ _ File#: ____________ _ Engineer: DSA#: ___________ _ Gallo Contractor: _________________ _ Other: ___________ _ INSPECTION MATERIAL SAMPLING QTY MATERIAL DESCRIPTION INSPECTIO N CHECKLIST -Structural Steel -H.S. Bolts -H.S. Bolts -,./ Plans/Specs _ Masonry -Prisms -Cone. PSI -Clearances -Concrete _ Mortar/ Grout -Grout PSI '1" Positions _ Fireproofing _ Cone. Cylinders Mortar PSI _ Sizes _L_ Epoxy _ Fireproof v'steel #5 _ Laps -Other: -Other: Elect./Wire -Consolidation -Other: -Other: Fireproof _ Torque Ft. Lbs: -Other: -Other: 7 Other: Sim~son ✓ Other: 6" embed Other: Other: Other: Other: Performed special inspection on the installation of #5 rebar dowels into existing foundation with simpson epoxy per details 4 of sheet 201. Verified bar types, sizes, hole sizes, depth, location, cleanliness and epoxy type. CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work inspected and does not constitute opinion or project control. I hereby certify that I have observed to the best of my knowledge all of the above reported work unless otherwise noted. I have found this work to comply with the approved plans, specifications, and applicable sections of the governing building laws. INSPECTOR: GIANNI BATTAGLIA CERT: 1323 ~ 7-12-22 ~ 1gnature Date lnsp. Date: Day 1: I Day 2: I Day 3: I Day 4: I Days: I Time Start: Time Stop: Approved By: _________ _ PrniPr.t SunPrintPn<IPnt • lW INTERWEST A SAA:bullt COMP.A~Y DATE: 4/7/2022 JURISDICTION: City of Carlsbad PLAN CHECK#.: CB-CBR2022-0102.RC1 PROJECT ADDRESS: 2704 Palmetto Drive PROJECT NAME: Singh-Res-Remodel SET: II □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ~ The check list transmitted herewith is for the applicant's information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to the jurisdiction at: D lnterwest staff did not advise the applicant that the plan check has been completed. ~ lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Manish and Neha Singh Telephone#: 442-244-0664 Date contacted: (by: ) Email: manishsingh08@hotmail.com Mail Telephone Fax In Person 0 REMARKS: By: Ellaine Esteller lnterwest 4/7/2022 Enclosures: NOTE: The items listed below are generally from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in underlined-bold font are current and are intended to further clarify the original comment. PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring IWSJ. corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. 2. Provide item-by-item responses on an 8-1/2-inch by 11-inch sheet(s) clearly and specifically indicating where and how each correction item has been addressed (vague responses, such as "Done" or "See plans," are unacceptable) GENERAL RESIDENTIAL REQUIREMENTS 3. The window looks to be 2'x1 ', as shown on the window schedule. There was no indication of mechanical ventilation on plans yet, therefore this correction applies. Water closet compartments shall be provided with aggregate glazing area in windows of not less than 3 square feet, one-half of which must be openable (unless mechanical ventilation is provided). Section R303.3. STRUCTURAL 4 . Please provide strapping to connect the room addition to the existing framing to transfer seismic and lateral loads. Provide justification the seismic and lateral connections of the new room addition to the existing framing are sufficient. , ELECTRICAL 5. Please show the following requirement for the new bathroom: Show on the plans a wall receptacle within 36" of each lavatory in the bathroom. CEC 210.52(0). 6. Could not find the note on the plans, please review. Per CEC Article 210.11 (C)3, note on the plans that bathroom circuiting shall be either: a) A 20-ampere circuit dedicated to each bathroom, or b) At least one 20 ampere circuit supplying only bathroom receptacle outlets. ENERGY CONSERVATION Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2 7. Please provide comply with the following requirement: Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the exterior. A bathroom is defined "as a room with a bathtub, shower, or spa or some similar source of moisture". 8. Please provide comply with the following requirement:Residential bathroom exhaust fans shall be energy star rated and shall be control by a humidistat capable of an adjustment between 50 and 80% humidity. CalGreen 4.506.1. Exception: Control by a humidistat is not required if the bathroom exhaust fan is also the dwelling whole house ventilation. Prescriptive Additions: See Section 150.2(a) through 150c) for additions and alterations 9. Please provide reply on the plans. The prescriptive measures for new fenestration are the following: U-Factor = .30, SHGC = 0.23. Please specify on plans the U-factor and SHGC of the proposed fenestration will meet prescriptive requirements. MISCELLANEOUS 10. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 11 . The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ellaine Esteller at lnterwest. Thank you. I • lW IN TERWEST A '>AI-Ebvalt COMPANY DATE: 1/27/2022 D APPLICANT D JURIS. JURISDICTION: City of Carlsbad A PLAN CHECK#.: cB-cBR2022-0102 sET:1 "!Cf:1vl:D PROJECT ADDRESS: 2704 Palmetto Drive Ctr-y 2 3 202z Bu Of: C PROJECT NAME: Singh-Res-Remodel lf..D1tvG °ARL.se Dtv AD IS;Otv D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ~ The check list transmitted herewith is for the applicant's information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to the jurisdiction at: Jason Patuit, Carlsbad Building Department D lnterwest staff did not advise the applicant that the plan check has been completed. ~ lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Manish and Neha Singh Telephone#: 442-244-0664 Date contacted: (by: ) Email: manishsingh08@hotmail.com Mail Telephone Fax In Person 0 REMARKS: By: Ellaine Esteller lnterwest 1/13/2022 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CB-CBR2022-0102 JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2704 Palmetto Drive FLOOR AREA: 1 70 SF Addition 50 SF Bathroom Remodel REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 1/27/2022 FOREWORD (PLEASE READ): STORIES: 2 HEIGHT: 10' for First Floor DATE PLANS RECEIVED BY ESGIL CORPORATION: 1/13/2022 PLAN REVIEWER: Ellaine Esteller This plan review is limited to the technical requirements contained in the California Residential Code, California Building Code, California Plumbing Code, California Mechanical Code, California I Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2019 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2019 CRC, 2019 CBC, 2019 CPC, 2019 CMC and 2019 CEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2019 California Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. PLANS Noted. 3 sets 1. Please make all corrections, as requested in the correction list. Submit FOUR new provided. complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring JYiSJ.. corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. Per comment 2. Provide item-by-item responses on an 8-1/2-inch by 11-inch sheet(s) clearly and abo-:,e,1rectpodnses specifically indicating where and how each correction item has been addressed are incu e on this list. (vague responses, such as "Done" or "See plans," are unacceptable) ,ee revised note ind CM alarms Jcated on lrawing 2/102. FIRE PROTECTION 3. When alterations, repairs or additions are proposed for dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms located as required for new dwellings; the carbon monoxide alarms shall be interconnected and ;M alarms located in (n) addition hard wired. Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315.2. ind hall only by 1se of exception ,rovided. ~cknowledged. GENERAL RESIDENTIAL REQUIREMENTS 4. Water closet compartments shall be provided with aggregate glazing area in windows of not less than 3 square feet, one-half of which must be openable (unless mechanical ventilation is provided). Section R303.3 . E) mechanical •entilation present. 5. For the existing study room, at least 1/2 of the common wall must be open and have 48 ft ·ct d an opening not less than 25 sq. ft., nor one tenth of the floor area of the interior room by ~~zer~:;n ~oor if light and ventilation is being supplied from an adjacent room. Section R303.2. and new pair of exterior glazed doors. Study to utilize existing house ventilation and HVAC. Ac;:knowledged. datums on sheet 101 are floor elevations. Refer to plan 2/102 for ceiling height datum elevations added. 6. Show that habitable rooms, hallways and basements shall have a ceiling height of not less than 7 feet. Bathrooms, toilet rooms and laundry rooms shall have a ceiling height of not less than 6'-8". Section R305.1. The ceiling heights on the proposed floor plan on Sheet 101 are indicated as 0'0". 7. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: Refer to exterior elevation on sheet 102 for added note. Refer to floor plan and interior elevation on sheet 101 for added notes. a. Glazing in doors. b. Glazing in the walls/doors facing or containing bathtubs, showers, hot tubs, spas, whirlpools, saunas, steam rooms and indoor/outdoor swimming pools where the bottom exposed edge of the glazing is less than 60" above the standing surface. Exception: Glazing that is more than 60", measured horizontally, from the water's edge of a bathtub, hot tub, spa, whirlpool or swimming pool. See the figure below. SG SG Plan view SG = Safety glazing required Measurements are to exposed glazing SG SG Section view ROOFS/DECKS/BALCONIES SG <60in. Floor ::i~~~0;;vised 8. Specify roof underlayment and layers of material to be used. Note ICC listing report sheet 201. on plans. Produt and ICC report listed 9. Where eave vents are installed, insulation shall not block the free flow of air. A Refer to revised section on 201. minimum of 1" of air space shall be provided between the insulation and the roof ~after size sheathing. To accommodate the thickness of insulation plus the required 1" ~xc{~~~~~~fng clearance, member sizes may have to be increased for rafter-ceiling joists. Section plan on 102 revised. R806.3. Ref~rto 10. Note on the plans: "Attic ventilation openings shall be covered with corrosion ~~~t~~ ~~d~hde~~te. resistant metal mesh with 1 /16" minimum to ¼" maximum openings. Section R806.1. . . . 11 . Please clarify if the proposed roof material will be concrete tiles or roofing tiles. The ~~~~e~: ~j!~9~~fer elevation on Sheet 102 and section on Sheet 201 state different materials. to section on sheet 201 for revised note. FOUNDATION REQUIREMENTS Refer to revised footing detail 12. Show on plans that wood shall be 8" minimum above finish grade. Figure R404.1. 7. 2/201 for added note Refer to plot plan on sheet 001 for added note. 13. Note on plans that surface water will drain away from building and show drainage pattern. The grade shall fall a minimum of 6" within the first 10 feet. Section R401 .3 Exception: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains or swales shall be constructed to ensure drainage away from the structure. Impervious surfaces within 10 feet of the building foundation shall be sloped not less than 2 percent away from the building. 14. Foundation anchorage in Seismic Design Categories C, DO, D1 and D2. In addition to the requirements of Section R403.1.6, the following requirements shall apply to wood light-frame structures in Seismic Design Categories DO, D1 and D2 and wood light-frame townhouses in Seismic Design Category C. R403.1.6.1 Refer to foundation plan on sheet 102 for added note. a. Plate washers conforming to Section R602.11 .1, 0.229"x3"x3", shall be provided for all anchor bolts over the full length of required braced wall lines. Properly sized cut washer shall be permitted for anchor bolts in wall lines not containing braced wall panels. Footing size has been added to 15. Please specify the continuous footing size, as shown on the foundation plan on foundation plan as Sheet 102. requested. A k I d d N1t6. Pdrovaine minimum of 4 inches of sand for the base of the slab. c now e ge . o e a ue fo foundation plan and detail 2/201 . 17. Provide typical connection detail of the existing footing to the new footing of the new room addition. Refer to detail 4/201 for requested connection to existing footing . STRUCTURAL f f . 18. Show stud size, height and spacing for all new walls on the plans. Maximum Re er to raming . . plan 3/102 for stud si~~ij~able stud heights shall be per section R602.3.1 . Max allowable per R602.3.1= 10', Provided max.= 9'-1". 19. Provide justification the seismic and lateral connections of the new room addition to the existing framing are sufficient. Roof to existing detail and section have been updated with fastener information. Product literature is included to justify shear strenght of connec.tors. 20. Provide connection detail of the 2x10 raners to the 4x headers. Specify hardware type and spacing for the connections. Typical notched rafter to dbl top plate . with Simpson A35 + Simpson hurricane tie @ea. rafter (16"o.c.) Refer to section on she:et d102 tfor 21 . Provide hurricane ties on each rafter in addition to the A35 clips as proposed. revise no e. 22. Provide connection detail of the proposed skylight to the roofing system on the Refer to detail 5/102 for requested plans. Please specify blocking sizes, hardware, and nailing, as specified in the information. manufacturer's specifications and UES report. . 23. Specify nail size and spacing for the floor and roof diaphragms on the plans. Table ~J~;~i~~tr~~5 R602.3(1 ). Specify plywood and/or particle board thickness, grade and panel span has been added to rating. Table R503.2.1 (1) roof framing plan 3/102 Addition is slab on grade, ELECTRICAL no sheathing at floor. 24. For a single-family dwelling unit (and for each unit of a duplex), show that at least GFCI outlet has beenone receptacle outlet accessible at grade level will be installed outdoors at the front ~~dnei~~~~~~t~i~I and back of the dwelling. CEC Article 210.52(E). This receptacle must be GFCI protected. 25. Per CEC Article 210.11 (C)3, note on the plans that bathroom circuiting shall be either: Note has been added to a. A 20-ampere circuit dedicated to each bathroom, or electrical plan on sheet b. At least one 20 ampere circuit supplying only bathroom receptacle outlets. 2/102 PLUMBING See 21102. 26. Show the shower stall can accommodate a 30" circle and has a minimum floor area 30" diam. circle of 1,024 sq. in. CPC Section 408.6. added. See 2/102. Clearance added. See 2/102. Note added. See plumbing note #2 on sheet 001 . 27. Dimension on the plans the 30" clear width required for the water closet compartment and the (minimum) 24" clearance required in front of the water closet. CPC 402.5. 28. Provide a note on the plans: The control valves in showers, tub/showers, bathtubs, and bidets must be pressure balanced or thermostatic mixing valves. CPC Sections 408,409,410. 29. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8 GPM of flow. CPC Sections 407, 408, 411 , 412. RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the Green Building Standards Code and must be enforced by the local building official. The following mandatory requirements for residential construction must be included on your plans. CGC Section 101.3. The Standards apply to newly constructed residential buildings, along with additions/alterations that increase the building's conditioned area, volume or size. CGC Section 301 .1.1. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. Acknowledged. Sheets added are 002 and 003. Note added. See sheet 002 Note added. See sheet 002 Note added. See sheet 002 Note added. See sheet 002 Note added. See sheet 002 Note added. See sheet 002 Note added. See sheet 002 Note added. See sheet 002 30. Storm water drainage/retention during construction. Note on the plans: Projects which disturb less than one acre of soil shall manage storm water drainage during construction by one of the following: A. Retention basins. B. Where storm water is conveyed to a public drainage system, water shall be filtered by use of a barrier system, wattle or other approved method. CGC Section 4.106.2. 31. Grading and paving. Note on the plans that site grading or drainage system will manage all surface water flows to keep water from entering buildings (swales, water collection, French drains, etc.). CGC Section 4.106.3. Exception: Additions not altering the drainage path. 32. Indoor water use. Show compliance with the following table, per CGC Section 4.303.1. FIXTURE FLOW RA TES FIXTURE TYPE MAXIMUM FLOW RATE Water closets 1 .28 gallons/flush Urinals (wall-mounted) 0.125 gallon/flush Urinals (others) 0.5 gallon/flush Showerheads 1.8 gpm @80 psi Lavatory faucets 1.2 gpm @60 psi1 Kitchen faucets 1.8 gpm @60 psi Metering faucets 0.20 gallons per cycle 1. Lavatory faucets shall not have a flow rate less than 0.8 gpm at 20 psi. 33. Note on the plans that when a shower is provided with multiple shower heads, the sum of flow to all the heads shall not exceed 1.8 gpm @ 80 psi, or the shower shall be designed so that only one head is on at a time. CGC Section 4.303.1.3.2. 34. Note on the plans that landscape irrigation water use shall have weather or soil- based controllers. CGC Section 4 .304.1. 35. Recycling. Note on the plans that a minimum of 65% of construction waste is to be recycled. CGC Section 4.408.1. 36. Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan, per CGC Section 4.408.2. 37. Operation and maintenance manual. Note on the plans that the builder is to provide an operation manual (containing information for maintaining appliances, etc.) for the owner at the time of final inspection. CGC Section 4.410.1. N t dd d 38. Note on the plans that the gas fireplace(s) shall be a direct-vent sealed-combustion s~e\tee1002 type. Woodstove or pellet stoves must be US EPA Phase II rated appliances. Note added. See sheet 002 Note added. See sheet 002 Note added. See sheet 002 Note added. See sheet 002 Note added. See sheet 002 HV AC not part CGC Section 4.503.1. 39. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC Section 4.504.1. 40. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 4.504.3 and Tables 4.504.1, 4 .504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC Section 4.504.2. 41 . Interior moisture control. Note on the plans that concrete slabs will be provided with a capillary break. CGC Section 4.505.2.1. 42. Interior moisture control. Note on the plans that the moisture content of wood shall not exceed 19% before it is enclosed in construction. The moisture content needs to be certified by one of 3 methods specified. Building materials with visible signs of water damage should not be used in construction. The moisture content must be determined by the contractor by one of the methods listed in CGC Section 4.505.3. 43. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star rated, vented directly to the outside and controlled by a humidistat. CGC 4.506.1. 44. Heating and air-conditioning system design. Heating and air conditioning of scope. New room systems shall be sized, designed and have their equipment selected using the following methods: (Support documentation required at application submittal) 4.507.2. to utilize existing house HVAC system. Note added. See sheet 002 a) Establish heat loss and heat gain values according to ANSI/ACCA Manual J- 2016, ASH RAE handbooks or other equivalent methods. b) Size duct systems according to ANSI/ACCA 1 Manual D -2016, ASHRAE handbooks or other equivalent methods. c) Select heating and cooling equipment according to ANSI/ACCA 3 Manual S - 2014 or other equivalent methods. Exception: Use of alternate design temperatures necessary to ensure the systems function are acceptable 45. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. Cheklist is completed and added to sheets 002 and 003 a) Complete a Residential Occupancies Application Checklist that includes the Notes 46-51 added to sheet 002. minimum criteria. It is available at: https://www.hcd.ca.gov/building- standards/calgreen/docs/hcdshl615c.pdf ENERGY CONSERVATION Residential Energy Lighting Requirements: ES 150.0(k) 46. All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A. a) Luminaries must have a label certified for airtight construction. b) Light sources that are not marked "JAB-2019-E" shall not be installed in enclosed luminaires. ES 150.0(k) 47. In bathrooms, garages, laundry rooms, and utility rooms at least one luminaire shall be controlled by a vacancy sensor. 48. Dimmers or vacancy sensors shall control all LED style luminaires. Two exceptions: Fixtures installed in hallways or (closets under 70 square feet). 49. Recessed can light fixtures shall be IC listed, air-tight labeled, and not be equipped with a standard medium base screw shell lamp holder. ES 150.0(k) SFD outdoor lighting fixtures that are attached to a building are required to be high efficacy, be manually on/off switch controlled, and have both motion sensor and photocell control. See ES 150.0(k) 3 for additional control options. Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2 50. Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the exterior. A bathroom is defined "as a room with a bathtub, shower, or spa or some similar source of moisture". 51 . Residential bathroom exhaust fans shall be energy star rated and shall be control by a humidistat capable of an adjustment between 50 and 80% humidity. CalGreen 4.506.1. Exception: Control by a humidistat is not required if the bathroom exhaust fan is also the dwelling whole house ventilation. Prescriptive Additions: See Section 150.2(a) through 150c) for additions and alterations 52. The prescriptive measures for new fenestration are the following: U-Factor = .30, SHGC = 0.23. Please specify on plans the U-factor and SHGC of the proposed fenestration will meet prescriptive requirements. Basis of Design: JEN-WELD V-4500 Series window. u-factor = 0.29 SHGC = 0.22 MISCELLANEOUS 53. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No )( 54. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Error! Reference source not found. at lnterwest. Thank you. [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK#.: CB-CBR2022-0102 PREPARED BY: Ellaine Esteller BUILDING ADDRESS: 2704 Palmetto Drive BUILDING OCCUPANCY: BUILDING PORTION Remodel Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code I AREA I (Sq.Ft.) 210 CB Valuation M(jtipier By Ordinance 1997 UBC Building Permit Fee • I :l',I ',I : 1997 UBC Plan Check Fee • I f.J •>t : Type of Review: Complete Review D Repetitive Fee □ Other ..., Repeats □ Hotny &Gil Fee DATE: 1/27/2022 Reg. Mod. D VALUE ($) Structural Only $1,067.951 Comments: In addition to the above fee, an additional fee of$ is due ( hour@ $ /hr.) for the CalGreen review. Sheet of (_ Citv of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST 8-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist 1s intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application It may be ~ecessary to supplement the completed checklist with supporting materials. calculations or cert1ficat1ons, to demonstrate rull compliance with CAP ordinance requirements For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE. The following type of permits are not required to fill out this form ❖ Patio ❖ Decks ❖ PME (1'1/o panel upgrade) ❖ Pool ,.. If an item In the checklist is deemed to be not applicable to a project. or Is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official > A Details on CAP ordinance requirements are available on the city's website. A A CAP Bu1ld1ng Plan template (form 8-55) shall be added to the title page all building plans This templat~be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application web g,d download the latest form. Pro1ect Name/Building Permit No : BP No · Property Address/APN: 21 3-1 80-1 5-00 Manish and Neha Singh 2704 Palmetto Drive, Carlsbad 9200 Applicant Name/Co .A.ppilcant Address. Contact Phone· 619.379.9642 ContactEmail. manishsingh08@hotmail.com Contact information of person completing this checklist (if different than above) Name: Company name/address Contact Phone: Contact Email: Applicant Signature __ _,k):::="'-,"·'-'------------Date: B-SC Page 1 of6 0 ( / O D /2-V 2-Z-r , Rev,seo 06/1 B , City of Carlsbad Climate Action Plan Consistency Checklist Use :he table below to determine which sections of the Ordinance Compliance checklist are applicable to your proJect For al:erations and additions to exIstIng buildings, attach Building PermiJ Vafuation worksheet Builo.ng Permit Valuation (BPV) from W0!l<S~eet: s ______ _ Construction Type @ Res1denual D New construction I Complete Sectlon(s) Low-rise High-rise 2A 3A. 4A 18, 28, 38,4A j Notes: A high-rise residential building is 4 or more stones 1nclud1ng a mixed-use building In which at least 20% of its conditioned floor area is residential use ---:-:---:--:------..L_--=,_.,,L..~:---1---------0 Add111ons and alterations. 0 BPV < S60,000 0 SPV 2 $60 000 D Electrical service panel upgrade only 0 BPV 2 S200 000 D Nonres,dent1al D New construction D Al:erat1ons □ BPV 2 S200,000 or additions 2 1.000 square feet 0 BPV 2 S1 ,000.000 D 2 2 000 sq ft nevi roof addition CheckHst Item 1A, 4A 4A 1A, 4A' 18, 4A· 18, 2B, 3B. 4B and 5 1B,5 1 B, 2B, 5 2B, 5 All residential additions and alterations 1-2 family dwellings and townhouses with attached garases only 'Mult1-family dwellings only where interior finishes are removec and significant site work and upgrades to structural and mechanical. electrical and/or plumbing systems are proposeo Building alterations of 2 75% ex1sllng gross floor area 1 B also applies 1f BPV 2 $200,000 Check the appropriate boxes, explain all not applicable and exception items, and provide supporting calculations and documentation as necessary. 1. Energy Efficiency Please refer to Car1sbad Municipal Code (CMC) sections 18 21155 and 18 30 190 and the Cahfom1a Green Building Slandards Code (CALGreen) for more information when completing this section A D Residential addition or alteration~ $60,000 building permit valuation. See CMC section 18.30.190. 0 NIA ________ _ D Exception· Home energy score ~ i (attach oertriicat1on) Year Built Single-family Requirements Multi-family Requirements □ Before 1978 Select one D Duct seahn □ Attic InsulatIon D Cool roof □ Attic insulation □ 1978 and later Select one O L1gh!1ng package D Water heating Package D Between 1978 and 1991 Select one □ Duct sealing El 1992 and later ! Select one D Lighting package B. D Nonresidential· new construction or alterations~ $200,000 building permit valuation, or additions ~ 1,000 square feet □ NIA □Attic Insula11on □Cool r:io' □Water heating package 2 ,(1ty of Carlsbad Cl!fnate Action Plan Consistency Checklist ____ s_ee_CMC 18.21 1 ss-:ind C~~n -Appendix AS, Division AS 2-Energy Efficiency. :..~ :~, · · .:·.c:-se .:in., □ 1 Ouc:ic· :,ghtng D 2 Wa·ehc.se dc~-seal-~ao~o:;..rs:..:..:._:.!._ __________ _ D 3 R:=~·"-'a·· sc:r, ~ ,•,a:e' ·eat·,9 .:c,-p, ,n· :::a fer a ::·e·g. C'.lde seco· ·4:, 5 as arne,cec1 D .: :~. a··\~}-~~r: □ 5 b.haJ)1 J1'reat ·eco,f.'·1 · 0 N:A ________ _ • ~ ..... 1 ... ' "·· ...... J ._ .:~c~se s·e _as_a_:i_~ :at_e__ _D __ s_s_E_ne_r_9y_b_ud_g_e_t ___ O_90_E_n_e_,gy_bu_d_ge_1 ______ D_N-_1A-:=======-:====-... = ,. 4 4 • 0, '"\...'l.1 D Or s11e ·erewao'ee _n_e....:rg'...'..y _______________________ .!:D::!...'..NJ:'.'A~===========-- A.S 2' 1 3- D G·::en cc.ve·' f o'iered ':Jy 1ocal utility provider. 50% minimum renewable soureesJ D E,e•1a1crs and escalators □ NIA ----------------------======::--::--: AS 2'3 1 D Ste-; 'rJm1ng • l":c1uaes 1ote1s rrolels a'1d h1gh-nse ·es1dent1al bu1kl1ngs 0 NIA -===--===-----:. ··• F:ir a :e"a; :irs '! S1 OOC COO BPV and affectmg > 75% existing gross floor area. or aller2t1ons that add 2 000 square fee'. ot new 'Ocf aod1t.on cor-ply wn1 CMC io 3C 13C irstead 2. Photovoltaic Systems '------------------------------A. D Residential new construction (for low-rise residential building permit applications submitted after 111120). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMG 18.30.150(8) (high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PVoffset opllon 1s selected. Floor Plan ID Jse add,tw1a1 CFA 1/rj u I Calcul ated kWdc- shee" hecessaa1 I I ----. ---Tota System S12e <vVdc = ,CFAx 572: I: 000 -(115 x 1/rj u i ·Form~la caicl.ia:1c1 where CFA = cono1l1ona1 noor area iidu:: rumber of :lwelhngs per plan type If proposed system size 1s less than calculated size, please expla1r □ - ,□ □ □ -- kWdc 8. D Nonresidential new construction or alterations ~$1.000,000 8PV and affecting ~75% existing floor area, or addition that increases roof area by ~2.000 square feet Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel butldings. Choose one of the following r.iethods ---- □ Gross Floor Area (GFA) Method GFA Min System Size kWdc □ Jf < 1 0 000s f Enter 5 ><Wdc □If~ 1 ::i ooos f calcu,ate 15 ~Wdc x rGFA/1 o ooo·, •• □Time-Dependent Valuation Method ------~-----,.., .... ,.., ____ ._ ____ _.. . ..., .. "" ________ _ ,City o" Carlsbad Cltmate Action Plan Consistency Checklist A~nual TDV E··ergy use ... x &O= Min system size ____ _ ,_wdc · .. Attach c;3cJlat1cn doc:.;mentat1on us,ng model.ng software approved by :he Cahiom,a Energy Comnss,or ---------3. Water Heat.Ing -----------------·-A. D Residential and hotel/motel new constru~tion Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. 0 Fo' systeT.s serving individual dwelling units. choose one 0 Hear purrp water heater AND Compact hot water d1str1but1on AND Drain water heat recovery (lov✓-r,se res.ceriIa: only) 0 Heat pump water heater AND PV system 3 kWdc larger than required ,n CMC section 18 30 130 (high nse res oent,al hotel/motel) or CA Energy Code section 150 1(c) 14 (low-nse res1dent1al) D heat pJmp water heater meeting NEEA Advanced Water Heating Spec1ficatIon Tier 3 or higher 0 So!ar Nater heating system that is either 60 solar savings fraction or 40 s f solar collectors O Exceo;1on ----------------------------------□ F ~-sysr.-::ris serving multiple dwelling units install a central water-heating system with al, of the fo:Iow1ng 0 Gas er propane water heating system 0 R~c,rculat1on system per CMC 18 30 150(6) (h,gh-rise res1dent1al, hotel/motel) or CMC i8 30 170IB) (low- ' se res dent:al) D Solar water heating system that Is either· D 20 solar savings fraction D 15 so'ar savings fraction plus drain water heat recovery OExcept1on S. D Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. D Wa,er heat ng system derives at least 40% of ,ts energy from one of the following (attach documentat,onl 0 Soar-thermal D Photovolta,cs D Recovered energy O Wate· heating system ,s (choose one) D Heat pump water heater □ E,ectnc resistance water heater(s) □Solar water heating system with 40 solar savings fraction D Exception ===================================-- r-· ! 1· ,..' \ , .:: :_ J 1 ... • City of Carlsbad Climate Action Plan Consistency Checklist 4. Electric Vehicle Charging A D Residential New construction and major alterations' Please refer to Carlsbad Ordinance CMC section 18.21.140 when completing this section. 0 One ana two-family residential dwelling or townhouse with attached garage 0 One EVSE Ready parking space required O Exception 0 Mulu-family res1dent1al D Exception . --i-Total Parking-Spaces EVSE Spaces ___ Proposed Capable Read Installed Tota_! __ _ Ca!cJ°a! c~s Total EVSE spaces= 10 x Total parking (rounded up to nearest whole number) EVSE Installed= Total EVSE Spaces x SO (rounded up to nearest whole number) EVSE other= Total EVSE spaces -EVSE Installed :EVSE ether may be "Capable ' 'Ready" or ·installed ") 'Ma.or al:erat•cns are (1) for one and two-family dwellings and townhouses with attached garages. alterations have a building perm rt valuauon::: S60 OOC or ncluae an electncal service panel upgrade: (2) for mulMam1ly dwellings (three units or more vnthout attached garages). alterations have a building permu va ~ai,or ::: S200 000 1nienor finishes are removed and significant site work and upgrades to structural and mechanical electncal. and/or plumbing systems are proposed . B. D Nonresidential new construction (includes hotels/motels) D Exception · I Total Parking Spaces EVSE Spaces I Proposed Capable I Readv I Installed Total I I I I Calculation Refer to the table below ----Total Nu1iber cf Park1nq Spaces provided Number of required EV Spaces Number of required EVSE lnslalled Spaces D 0-9 1 1 D 10-25 2 1 -D 26-50 4 2 D 51-75 6 3 □ 76-100 9 5 [] - 6 101-150 12 D 151-200 17 9 fl 201 and over 10 percent of total 50 percent of Required EV Spaces - • r,ify of Carlsbad Climate Action Plan Consistency Checklist An app;;ved T·ansoor.at ::1 Derra,d Manage'Tlen: (TDM) Plan 1s required for al! nonresidential ;iroJects that rieet a t1resrold c; e".lpoyee-ge~e·atec AOT Crty sta "111 use 11e table below basec on your st.or.1tted plans to deterrrnne ,•1hether or nor your perrr,t req J1res a TOM Par .f "'"OM is a:Jp ica:i!e :c 'c. · pe"Tl : staF wi' contact the applicant ,o develop a s1te-spec1~c TOM pla1 oased or. the perrr1t deta:1s Acknowledgmeri Employee ADT Estimation for Various Commercial Uses Emp ADT for Emp ADTI Use . . first 1,000 s.f. 1000 s.f., ;J I Office (all)< I Restaurant Reta11J I Industrial i Manufacturing Warehousing 20 11 8 4 4 4 , Unless otherwise noted. rates estimated from !TE Tnp 13 11 45 3.5 3 I Generation Manual, 1 O:"Ed1t1on 2 For al l office uses. use SAN DAG rate of 20 ADT/1 000 sf to · calculate employee AOT 13 Retail uses include shopping center. variety store supermarket gyms. pharmacy etc I Other commercial uses may be subject to special I consideration j Sample calculations: I Office 20.450 sf 1. 20.450 sf / 1000 x 20 = 409 Employee ADT I Retail 9 334 sf 1 First 1.000 sf= 8 AOT 2 9 334 sf -1.000 sf= 8,334 sf 3. (8,334 sf / 1.000 x 4 5) + 8 = 46 Employee ADT I acknowledge that the plans subm1ttea may be sub1ect to the City of Car1sbaa s Transportation Demand Management Ora1nance I agree tJ De contacted shot. d my perrr1t ·eqwe a TOM plan and understand that ar. approved TOM plan 1s a cond1uon of permit issuance App11can: S,gna:ue /, --il Date O / / V C /z_ C LL Person other than Applicant to be contacted for TOM compliance (if applicable): Na"le _pnnted; ____________________ _ Phone Nurrber _____ _ E-naJ/ Add·ess ____________________ _