HomeMy WebLinkAbout2407 BADGER LN; ; CBR2022-3721; PermitPrint Date: 12/28/2022 Permit No: CBR2022-3721
Building Permit Finaled
Residential Permit
Job Address:
Permit Type:
Parcel #:
Valuation:
Occupancy Group:
2407 BADGER LN, CARLSBAD, CA 92010-7149
BLDG-Residential
2091104800
$20,000.00
Work Class:
Lot #:
Project #:
Cogen
Status:
Applied:
Issued:
10/06/2022
10/13/2022
Finaled Close Out:12/28/2022
#of Dwelling Units:
Track #:
Plan #:
Closed - Finaled
Plan Check #:
Orig. Plan Check #:Bathrooms:
Final Inspection:11/02/2022Bedrooms:Construction Type:
Occupant Load:
Code Edition:
Sprinkled:
INSPECTOR:de Roggenbuke, Dirk
ROOF MOUNT SOLAR, 7.92KW SYSTEM SIZE, 22 PV MODULES, 100A MCB DERATE (E-REVIEW)Description:
Project Title:
Applicant: JORDAN LYKINS
8260 STATE HIGHWAY 193
GARDEN VALLEY, CA 95633-9447
(530) 334-0676
Contractor: GOLD RUSH ENERGY SOLUTIONS
4911 WINDPLAY DR, # STE 4
EL DORADO HILLS, CA 95762-9643
(866) 557-6937
AMOUNTFEE
SB1473 – GREEN BUILDING STATE STANDARDS FEE $1.00
SOLAR–RESIDENTIAL: per kW $289.00
STRONG MOTION – RESIDENTIAL (SMIP)$2.60
Total Fees:$292.60 Total Payments To Date:$292.60 Balance Due:$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad CA 92008-7314 ï 442-339-2719 ï 760-602-8560 f ï www.carlsbadca.gov
Building Division Page 1 of 1
{"Cityof
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Check
Est. Value
PC Deposit
Date
Job Address Unit:APN:
CT/Project #: Lot #: Year Built:
BRIEF DESCRIPTION OF WORK:
PROPERTY OWNER
Name:
Address:
State: Zip:City: State: Zip:
Phone:
APPLICANT
Name:
Address:
City:
Phone:
Email: Email:
DESIGN PROFESSIONAL CONTRACTOR OF RECORD
Name: Business Name:
Address:
City: State: Zip:
Phone:
Email:
Architect StateLicense:
Address:
City: State: Zip:
Phone:
Email:
CSLBLicense #: Class:
Carlsbad Business License # (Required):
APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information of the plans is accurate. I
agree to comply with all City ordinances and State laws relating to building construction.
NAME (PRINT): DATE:
1635 Faraday Ave Carlsbad,CA92008
SIGN:
Ph:-2719 Email:Building@carlsbadca.gov
1 REV.
New SF : Living SF,_Deck SF,Patio SF,Garage SF
Is this to create an Accessory Dwelling Unit? Y N New Fireplace? Y N , if yes how many? _________
Solar:KW, Modules, Mounted: Roof Ground, Tilt: Y N, RMA: Y N,
Battery: Y N, Panel Upgrade: Y N
Other:
Additional Gas or ElectricalFeatures?Pool/Spa:SF
Is the area a conversion or change of use?Y NRemodel:SF of affected area
□
□
□
□
( City of
Carlsbad
2407 Badger Lane,Carlsbad,CA,92010,
Roof Mount Solar, 7.92kw System Size, 22 PV Modules, 100A MCB Derate
0 0 00
0 0
Addi
7.92 22 () 0 00 0 e
00 00 Electric Meter number:
Main Circuit Breaker Derate 1 00A
(PRIMARY CONTACT)
Gold Rush Energy Solutions
4911 Windplay Drive Suite 4
EL Dorado Hills CA ---530.391.4 716
permits@goldrushenergy.com
Jordan Lykins
95762
442-339
Venky Venkatesh
2407 Badger Lane
Carlsbad CA 92010
(760) 798-0510
maudgalyas@gmail.com
Gold Rush Energy Solutions
4911 Windplay Drive Suite 4
EL Dorado Hills CA 95762 -------866.557.6937
permits@goldrushenergy.com
1014971 B, C-10
Business License 24417
10/06/2022
04122
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: __________________
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING
THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE.
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I herebyaffirmunderpenaltyofperjurythat I amlicensedunderprovisionsofChapter 9 (commencingwithSection7000)ofDivision3
oftheBusinessandProfessionsCode,andmylicenseisin full forceand effect. I alsoaffirmunderpenaltyofperjuryoneofthe
following declarations (CHOOSE ONE):
I have and will maintain a certificate of consent to self-insure for workers’ compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued. PolicyNo.
-OR-
I have and will maintain worker’s compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers’compensation insurance carrierand policynumberare:InsuranceCompany Name:
Policy No. _____________________________________________________________ Expiration Date:
-OR-
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become
subject to the workers’ compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
interest and attorney’s fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender’s Name: Lender’s Address:
CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and
utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are
not approved for construction and may be required to be altered or removed. The city’s approval of the application is based on the premise that the submitted documents and plans show
the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed
use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation.
All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT): SIGNATURE:DATE:
Note: If the person signing above is an authorized agent for the contractor provide a letter of authorization on contractor letterhead.
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor’s License Law for the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor’s License Law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
-OR-
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor’s License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor’s License Law).
-OR-
I am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
AND,
FORM B-61 “Owner Builder Acknowledgement and Verification Form” is required for any permit issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors.I understandthat a copyoftheapplicablelaw,Section7044oftheBusinessandProfessionsCode,isavailableuponrequestwhenthisapplicationis
submittedor at the following Website: http://www.leginfo.ca.gov/calaw.html.
OWNER CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility
easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved
for construction and may be required to be altered or removed. The city’s approval of the application is based on the premise that the submitted documents and plans show the correct
dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each
building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All
improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT): SIGN:DATE:
Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner.
1635 Faraday Ave Carlsbad,CA92008 Ph:--2719 Email:Building@carlsbadca.gov
2
REV.
- OR -
□
State Compensation Insurance Fund
922480120 01/20/2023
□
Jordan Lykins 10/6/2022
□
□
□
□
442 339
04/22
Building Permit Inspection History Finaled
PERMIT INSPECTION HISTORY for (CBR2022-3721)
BLDG-Residential 10/06/2022Application Date:Permit Type:Owner:
Cogen 10/13/2022Work Class:Issue Date:Subdivision:
05/01/2023Expiration Date:Status:
IVR Number: 43831
Closed - Finaled 2407 BADGER LN
CARLSBAD, CA 92010-7149
Address:
Scheduled
Date
Inspection Type Inspection No. Inspection
Status
Primary Inspector Reinspection InspectionActual
Start Date
11/02/2022 11/02/2022 BLDG-35 Solar Panel 195595-2022 Passed Dirk de Roggenbuke Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency Yes
BLDG-Final Inspection 195594-2022 Passed Dirk de Roggenbuke Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Wednesday, November 2, 2022 Page 1 of 1
{cityof
Carlsbad
10/06/2022
RE: Structural Certification for Installation of Residential Solar
Code 2019 California Building Code (ASCE 7-16)
Risk category II Wind Load (component and Cladding)
Roof Dead Load Dr 15 psf V 110 mph
PV Dead Load DPV 3 psf Exposure C
Roof Live Load Lr 20 psf
Ground Snow S 0 psf
If you have any questions on the above, please do not hesitate to call.
Sincerely,
Eugene Munyanziza, P.E.
EV Engineering, LLC
projects@evengineersnet.com
http://www.evengineersnet.com
Exp: 06/30/2024
VENKY VENKATESH:2407 BADGER LN, CARLSBAD, CA 92010
Attn: To Whom It May Concern
This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the
PV system to existing roof framing. From the field observation report, the roof is made of Concrete Flat Tile
roofing over roof plywood supported by 2X4 Rafters at 24 inches. The slope of the roof was approximated to be
23 degrees and the allowable maximum rafter span is 6 feet between supports.
After review of the field observation data and based on our structural capacity calculation, the existing roof
framing has been determined to be adequate to support the imposed loads without structural upgrades.
Contractor shall verify that existing framing is consistent with the described above before install. Should they
find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity
calculations were done in accordance with applicable building codes.
Design Criteria
projects@evengineersnet.com
http://www.evengineersnet.com
~EV
ENGINEERING
Structural Letter for PV Installation
Date: 10/06/2022
Job Address:2407 BADGER LN
CARLSBAD, CA 92010
Job Name:VENKY VENKATESH
Job Number:221006VV
Scope of Work
Table of Content
Sheet 1 Cover2Attachment Uplift checks3Roof Framing Check
4 Seismic Check and Scope of work
Engineering Calculations Summary
Code 2019 California Building Code (ASCE 7-16)
Risk category II
Roof Dead Load Dr 15 psf
PV Dead Load DPV 3 psf
Roof Live Load Lr 20 psf
Ground Snow S 0 psf
Wind Load (component and Cladding)
V 110 mph
Exposure C
References
NDS for Wood Construction
Sincerely,
Eugene Munyanziza, P.E.
EV Engineering, LLC
projects@evengineersnet.com
http://www.evengineersnet.com Exp: 06/30/2024
This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the
PV system to existing roof framing. All PV mounting equipment shall be designed and installed per
manufacturer's approved installation specifications.
projects@evengineersnet.com
http://www.evengineersnet.com
-
~EV
ENGINEERING
Wind Load Cont.
110 mph ASCE 7-16 Figure 26.5-1B
C
1.0 ASCE 7-16 Sec 26.8.2
0.93 ASCE 7-16 Table 26.10-1
0.85 ASCE 7-16 Table 26.6-1
1.00 ASCE 7-16 Table 26.9-1
24.35 psf
23.0 Degrees
1.5 Conservatively assuming all exposed
0.8 conservatively assuming 10 ft2 effective area
Uplift (W)Zone(1) Zone(2r) Zone(2e)Zone(3)
Fig. 30-3-2 GCp=-1.8 -2.2 -2.2 -2.1
Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-52.60 -64.29 -64.29 -61.37
GCp=0.7 Figure 30.3-2
P=qh(GCp)(γE)(γa)=11.69 Equation 29.4-7
Rafter Attachments: 0.6D+0.6W (CD=1.6)
Connection Check
Attachment max. spacing=6 ft
5/16" Lag Screw Withdrawal Value=266 lbs/in Table 12.2A - NDS
2.5 in DFL Assumed
Prying Coefficient 1.4
Allowable Capacity= 760 lbs
Zone Trib Width Area (ft) Uplift (lbs) Down (lbs)
Zone(1)6 16.5 314.4 242.3
Zone(2r)6 16.5 380.6 242.3
Zone(2e)6 16.5 380.6 242.3
Zone(3)6 16.5 364.0 242.3
Conservative Max=380.6 <760
CONNECTION IS OK
Risk Category =
KZ =
Kd =
Ke =
2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw.
Embedment in sheading or other material does not count.
II
V=
Exposure =
1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift
governs
γE=
γa=
KZt =
qh= 0.00256KzKztKdKeV2=
Pitch =
Lag Screw Penetration
projects@evengineersnet.com
http://www.evengineersnet.com
~EV
ENGINEERING
Vertical Load Resisting System Design
Roof Framing Rafters
Snow Load Fully Exposed
pg= 0 psf Ct =1.1
Ce =0.9 Is =1.0
pf = 0 psf
pfmin. = 0.0 psf
ps = 0 psf Conservatively (Cs=1)0 plf
Max Length, L =6.0 ft (Rafter maximum Allowable Horizontal Span)
Tributary Width, WT =24 in
Dr =15 psf 30 plf
PvDL =3 psf 18 plf
Load Case: DL+0.75(0.6W+S)
0.75(Pnet+Ps)+ Ppvcos(θ)+PDL=59 plf
Mdown=263 lb-ft
Mallowable = Sx x Fb' (wind)=456 lb-ft >263 lb-ft OK
Load Case: DL+S
Ps+ Ppvcos(θ)+PDL=48 plf
Mdown=216 lb-ft
Mallowable = Sx x Fb' (wind)=456 lb-ft >216 lb-ft OK
Load Case: DL+0.6W
Pnet+ Ppvcos(θ)+PDL=62.0 plf
Max Moment, Mu=279 lb-ft
Mallowable = Sx x Fb' (wind)=634 lb-ft >279 lb-ft OK
Pv max Shear=242.3 lbs
Shear, Vu=wL/2+Pv Point Load =386 lbs
Max Shear, Vu=wL/2+Pv Point Load =386 lb
Member Capacity
DF-L No.2
2X4 CL CF Ci Cr KF φ λ
Fb =900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi
Fv =180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi
E =1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi
Emin =580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi
Depth, d =3.5 in
Width, b =1.5 in
Cross-Sectonal Area, A =5.25 in2
Moment of Inertia, Ixx =5.35938 in4
Section Modulus, Sxx =3.0625 in3
Allowable Moment, Mall = Fb'Sxx =396.2 lb-ft DCR=Mu/Mall =0.58 < 1 Satisfactory
Allowable Shear, Vall = 2/3Fv'A =630.0 lb DCR=Vu/Vall =0.61 < 1 Satisfactory
Design Value Adjusted Value
projects@evengineersnet.com
http://www.evengineersnet.com
~EV
ENGINEERING
-
-
-
Siesmic Loads Check
Roof Dead Load 15 psf
% or Roof with Pv 18.19%
Dpv and Racking 3 psf
Average Total Dead Load 15.5 psf
Increase in Dead Load 1.8%OK
The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and
therefore no further seismic analysis is required.
Limits of Scope of Work and Liability
We have based our structural capacity determination on information in pictures and a drawing set titled PV plans -
VENKY VENKATESH. The analysis was according to applicable building codes, professional engineering and design
experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the
proposed solar panel installation referenced in the stamped plan set and were made according to generally
recognized structural analysis standards and procedures.
projects@evengineersnet.com
http://www.evengineersnet.com
~EV
ENGINEERING
I I