HomeMy WebLinkAbout2776 GATEWAY RD; ; CBC2021-0356; PermitPERMIT REPORT (city of Carlsbad Commercial Permit Print Date: 07/25/2022 Permit No: CBC2021-0356 Job Address: 2776 GATEWAY RD, CARLSBAD, CA 92009-1730 Status: Closed -Finaled Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel #: 2133000700 Track#: Valuation: $354,871.30 Lot#: Occupancy Group: B Project#: #of Dwelling Units: Plan#: Bedrooms: Bathrooms: Construction Type:V-B Orig. Plan Check#: Plan Check#: Project Title: Description: CARLSBAD PLANNING CENTER: 7,630 SF Tl OFFICE TO OFFICE FEE Property Owner: JEFF BERG 2790 GATEWAY RD CARLSBAD, CA 92009 BUILDING PLAN REVIEW-MINOR PROJECTS (LDE) BUILDING PLAN REVIEW-MINOR PROJECTS (PLN) BUILDING PLAN CHECK FEE (manual) SB1473 -GREEN BUILDING STATE STANDARDS FEE GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION STRONG MOTION -COMMERCIAL (SMIP) COMM/IND Tl -NON-STRUCTURAL Total Fees: $3,603.60 Total Payments To Date: $3,603.60 Applied: 09/15/2021 Issued: 11/24/2021 Finaled Close Out: 06/24/2022 Inspector: Final Inspection: Contractor: N BRUNO BUILDER INC 1027 SUNSET DR TKers 06/24/2022 VISTA, CA 92081-7405-SAN DIEGO (760) 801-3045 Balance Due: AMOUNT $194.00 $98.00 $1,306.14 $15.00 $175.00 $99.36 $1,716.10 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov \('CiJ;yof Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Chtck C/i29{kf/,}' (2i:Jl:, £st. value 8 :SS::':J., K.?JJ30 PC Peposl~ ______ _ Oate q-1£,-ell Job Address 2776 Qaleway Aoao, ~. CA 92009 SUfte:,..,. ___ ...iAPN· 21S,30C)..0100 Tenant Name#~ PiaMfnoC-.CarllbadT.I. lot#: Year Sulit! _______ _ Vear luflt:. __ _ Occupancy...,• s__ Construction Type: v-a Fire sprtnktenOes@No A/C-@tES°'O BRlEF bESCRlPTION or WORk: Ttnanl Improvement IJ)ICl& Will oocupyfNtomlreeidatlnQ ~tovtil alb~ This permit iodUdel --~ ~ plumblnQ atldeledllcal ¥tOlfl, Noelle WOfk Is proP!)lad. 0 AddWon/New:. __________ New SF and Use,, _______ _, ew SF and Use ______ SF Deck, SF Patio Cover, SF Other (Speclfy),_• --- 0fena,at lmprovemene_7,_630_· ___ SF, Ex1sting Use: _8 _____ Proposed Use: _e ____ _ ____ SF, Existing Use: Proposed Use: _____ _ D Pool/Spa1. ____ .SF Addltionet Gas or ElectrlcalFeature.s? __________ _ 0 Solar:. ___ KW, ___ .Module.s, Mounted:0Roof 0Grou~d 0 Reroof;, ______________________________ _ [!) Plumbln8/MechanJcaV£1ectrk:at P/M/E u~ated as required for T.I. □Other: _________________________ _ P1tfMAftY APPUCANT Name· l<lfkMoeler Address: 2888t.Clklr Ave east. Suite~ City: C1r111bac1 State•._c_A __ .llp: 92010 Phone: 760-81Ut2$ Emall:~.QOll'I QESIGH PltOFESSIOHAl. PltO~Effl OWNER Ntme: Jeff aero Addreu:2776Gale'#aV Rold Qty: c.debad. Phone; 76()..567-llOSt Emam ~ CONTMCTOR OFAECOJU) Stat.: CA Zlp:_nooe ___ _ Name: lllllH#l)Mlll'Yllfll)llcllrll 8uslne$5 Mame,..,· N_. eruno __ Bi_i.!IIW __________ _ Add~u· AddNSS;_1027_SuMet_·_·_~_. ___________ _ City:. State: Zip: aty:; Vlltl State: CA .z,p:,_9208_1 ___ _ Phone· Phone .. · .. 1_so-...;~_1_~_. ____________ _ Email:. _______________ £mall:._"_·~-·--•·,..;-. __,com _____ ""2" ____ _ Architect State License: c-MOUI CSLB license .. 3 ~3:\ \2 0 ;..,.e; ____ _ Carlsbad Business license# f11111d116 l-1.-S I S"' . Ye~c..e. ~ 1\ APPUCANTCERTIFICATION: lcertlfythatlhowreodthe appltcatfonandstatethot~ooovelnformatfonlscorrectdndthatthi lnformottonontMplanslsoccurate. Jogree to comply with all City ordinances and State tows relating to building construction. ~ NAME (PRINT): Kirk Moeller SIGN: ... ~,.;;2e -. DATE:_S.-_1_4-_2_1 --- 1 REV, 07121 THIS PAGE REQUIRm AT PERMIT ISSUANCE Pl.AN CHECK NUMBEI\: ~-03S:ID A 8\.U1.0llllG PERMIT CAN S't lSSU£D TO EtTfffR A S'tATe UttNSED CONTRAC'fOR 09 A PROPlffl OWNEft tF TME PERSON StGNl:NG THfS FORM IS AN AGE~T FOR £tnt!lt ,r,f11TY Ar. AUfH()JUtATION FORM ()RJ.tmR 1$ RE(UJIJ\£0 PRtOR TO PlRMlT ISSUANCE. (OPTlONA):,U§fr,jSEO CON1RAtJ9J l?ltl!RATION: · therebyofllrmunderpenoltvofperjurythotlomllcen$edunderprovlsfonso/Chopter9(commencfnjw1thSeetlon7000)t>/DlvlstonJ of the Business and Professions Code, andmyitce1ue lsln fuU forceonde/fect.. lal$0o{/trm underpeooltyof per)1Jryoneof the following declarations (CHOOSE ON£): □• tiew .,-,ct Will nmn:tatn • ~of tonsent to s~IMura tor WOJ'M(l' conipfl\Slltltrll pro..tded by $«ctl(WI 3700 of the Ulbor Code. for the peffotll\4nte of the workwbldtthtspeonlt ls.lwted. Pollt.VN,.,,_ ___________________ ~-------- ~ n1 hMI at\d wlll rnalnlalo worbr's compen~t!Pn. at reqofrecf by Sfftlon 37QO<if the llbor-0:ldt. fQC' the pelf. ormatte:.• ol thawoc1cforwtllth thlf JH!fmlt ls 1u11ed. ~ ~ ~nsatlO!'l litst.nnteflllrrlet and pollcyn~r ~lll hWJfllJIQComPiUIY Name: _________________ _ PoflcyHo. ____________________ E:xplrattonl>ah: ___________ _ '~h"" • e of Eicemplk>m I c.rtlfv tblt 1n the pettor1n11ncaof the wottt for whlc.hth15 petrntt ls ruued, 1 JhaJI not employ any person In MY Mintier ai:> as to be(Oll'WI ~~w()t(cefS' compensation laWsofedfomfa. WJWllftG:F ... toffQIN~compmuitlonc;oweracels....,,.,MdillllMlttet•__,,.,to almlul,......ffld Clllllflnes 11PtO poo,aoo.oo. In addltfan the to tba Cciltof ... ltloll, dmlqis ., pr~ b In 5eCtloh 9706of the .... Codit, l.nwre,tlll'l(I attotney'• .._.. SJ!NSTRl,JalQN L!NDlfj§ A§gllKY, ! M: l hefftv•fflrm that 1h«e ls I twlruttloti lendf!ll tlffltY for ~ perfCWl'l'llll'IC4 of Int wor.k Ults Jlffll)lt IJ tnuad (S.C. W97 (i) CMI (o(kl). ~-~----------------'-t11dat'1JA41dntm ______________ _ COHTRACTOR C£RTIF1CATION: lcertlbt.hatlhavereadthe apptlcotlonandstotethottheabowfnformat#onlscorrectandthctt thtt ln/ormattonon the plans Is accurate. Jogree to comply With alt City ordf ntJnces and State laws relating to building construction. N.AME 1~jc.&wn n SIGNATIJR£,Jl.A 4----4._ .,_ -• 11 Is: I :2-1 l'fote: ffthlt..-....... ~ .. for ... ----........ ,_.,,,~-conb'lldOt'~ -OA - (OPTtON-8): OWNE8-8Uf\0~R OfCtARATIOH;. thereby affirm that I om exempt frr>m Contract~r's License Law for the followllll reason; r7 t,asow,.,ofttiepropenyorfl\V~'~wa,esnthelrsole~ wflldothewotttandtbt~•&not~o.-~tw•'5H- ~.~and Profes$IQIIS eodr.. TMCMtn1ctOl"•.t.lalfl11 L-,doti not,_....,to.,. owiwrof p,Clflllll1Ywho Wkls Of lftlp[O!lff ~and who doas tUCh wo,t hlm,eff orthrou,h hit own ~s, 111ovlded thatsudl lmprowmenlS ate not Intended ot offe,ed tor Ale. If, howev«. the bulldmc or I~ 11 sold Within o.oa ye11r of~ \be ~builder WIii tiav•tha burden of pro>A"' tlttt 1141 did not blllld ot hnprove fot thl ~ ot ui.}. .QR,, 01, • owner of the p,opmy, ern lll<dushl!lly ,omrtttln, with kensed ~on to cons.truct ·11\t projel:t (S.C. 7044, ~ w .Prohtulom COd•: Tltt Cotitrktor'• lJcanle I.aw doe not •PPIY to .i owner of PIVPfflV who bulllb wlmJ>f.cWes thft•oo. w con~ct• fo,: .u(h proft(ts 1111th c:ontrattorl•) lkMs-' ~ to moeontfa=(• ~uiw), ~ e,cempt under BuJlneUtnd Profusion, c:ode OMsk>n a. en.ptor 9, Attict. 3 t1;1rttu, rU$0n: AND, □FORM 8-61 *OWner Bitlkler ~ and Vttlffl:•tlon f4tm" ls required roony permll Issued to a pcc,perty oWMJ. av my sl&naWf• below I acknovMdgettlaf, ex~ for my personfl resldenu ln whlch I ti\Ust hiwo ,-5kftd fl)( at t.ast on.yur p,1ot to ~pliitlofl of tlMI trn~t.s covered by this permit, I eamot ttt•lly sell • $ltllfflffl! th11t I hlM! bullt as an owner-bulidel' If It ha$ not been q,nstrocted If\ fts entnty bilf lioenslid e011trac:ton.iundmtondthatacopyoftlwopplkabl1low,s«tton~ofthe8usfne>slandPto{ffllJ,ns.Code,lsovollol2'1...,_.rt'qW$tW'M'llthlsappllcatlonls submlttfdor ot t,,. followliJJ w~ dtll nttp: I twww. legln/<1,CD.gtNlcof!)w.httnl. OWNER C£RTIFICA TIOH: lcertlfyttratlhove reodthtt appllwttonand$tate that theobove ln[ormatlon Is correct and that the Information on thtt pla1'i$ls accurate. I agree tocomp(y with oll City ordlnat1Ce$ and State laws relating to building cotrstructlon. NAME (PAINT): _________ SIGN: ________ DATE:. _____ _ Notll:lftM ..... ..._._. llan IIUdlorilad.,..fortMPl'Of,lfflYOWMr _..form8"2dpidl1¥propenyOMW. 1635 Fflnl'hv Ave c.,~, CA 92008 REV.<11/21 { City of Carlsbad OWNERS AUTHORIZED AGENT FORM B-62 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov OWNER'SAUTHORIZED AGENT FORM Only a property owner, contractor or their authorized agent may submit plans and applications for building permits. To authorize a third-party agent to sign for a building permit, the owner's third party agent must bring this signed form, which identifies the agent and the owner who s/he is representing, and for what jobs s/he may obtain permits. The form must be completed in its entirety to be accepted by the City for each separate permit application. Note: The following Owner's Authorized Agent form Is required to be completed by the property owner only when designating an agent to apply for a construction permit on his/her behalf. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Property Owner Acknowledgement, the execution of which I understand Is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project. Tenant Improvement of existing office buildin Scope of Construction Project (or Description of Work): __________________ _ 2776 Gateway Road, Carlsbad, CA 92009 Project Location or Address: ___________________________ _ Kirk Moeller, Kirk Moeller Architects, In, 760-814-8128 Name of Authorized Agent: _________________ Tel No. ________ _ 2888 Loker Ave East, Suite 220 Address of Authorized Agent:. ___________________________ _ Carlsbad, CA 92010 I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above Information and certify its accuracy. ~(J.,~5R ~-Property Owner's Signature: ________ z_'--______ ,.;,_ ___ Date: _ __,;;,9_/1...;0;_/2;.;..1 __ _ 1 PERMIT INSPECTION HISTORY for (CBC2021-0356) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed -Finaled Application Date: 09/15/2021 Owner: JEFF BERG Issue Date: 11/24/2021 Subdivision: Expiration Date: 09/28/2022 IVR Number: 35905 Address: 2776 GATEWAY RD CARLSBAD, CA 92009-1730 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS 06/24/2022 06/24/2022 BLDG-Final Inspection 185633-2022 Monday, July 25, 2022 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS Status Passed Tim Kersch Passed Yes Yes Yes Yes Yes Passed No Yes Yes Yes Yes Complete Page 2 of 2 Building Permit Inspection History Finaled {City of Carlsbad PERMIT INSPECTION HISTORY for (CBC2021-0356) Permit Type: BLDG-Commercial Application Date: 09/15/2021 Owner: JEFF BERG Work Class: Tenant Improvement Issue Date: 11/24/2021 Subdivision: Status: Closed -Finaled Expiration Date: 09/28/2022 Address: 2776 GAT EWAY RD IVR Number: 35905 CARLSBAD, CA 92009-1730 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 12/06/2021 12/06/2021 BLDG-21 171963-2021 Passed Tim Kersch Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/19/2022 01/19/2022 BLDG-14 174789-2022 Passed Tim Kersch Complete Frame/Steel/Bolting/We lding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/21/2022 01/21/2022 BLDG-84 Rough 175020-2022 Failed Tim Kersch Reinspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Fali No BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 No to mech code. No Rough-Ducts-Dampers 01/25/2022 01/25/2022 BLDG-84 Rough 175233-2022 Passed Tim Kersch Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Fali Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 No to mech code. No Rough-Ducts-Dampers 02/04/2022 02/04/2022 BLDG-17 Interior 175961-2022 Passed Tim Kersch Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/01/2022 04/01/2022 BLDG-85 T-Bar, Ceiling 179605-2022 Passed Tim Kersch Complete Grids, Overhead Monday, July 25, 2022 Page 1 of 2 • lW INTERWEST A :,A~ttllJI I COMPtlNV DATE: 11-3-2021 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2021-0356.RC1 PROJECT ADDRESS: 2776 Gateway Road PROJECT NAME: Planning Center-TI SET: II □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. ~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ lnterwest staff did not advise the applicant that the plan check has been completed. D lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Email: Mail Telephone Fax In Person ~ REMARKS: All structural sheets must be signed by engineer before permit can be issued. By: Erich A. Kuchar, P.E. lnterwest Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 • 1W INTERWEST A SArEbuilt COMPANY DATE: 9-30-2021 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2021-0356 PROJECT ADDRESS: 2776 Gateway Road PROJECT NAME: Planning Center-TI SET: I □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. 1:8'.] The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D lnterwest staff did not advise the applicant that the plan check has been completed. 1:8'.] lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Kirk Moeller Telephone#: 760-814-8128 Date contacted: (by: ) Email: kirk@kmarchitectsinc.com Mai l Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P .E. lnterwest Enclosures: 9320 Chesapeake Drive, Sui te 208 ♦ San Diego, Califo rnia 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC2021-0356 9-30-2021 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK#.: CBC2021-0356 OCCUPANCY: B TYPE OF CONSTRUCTION: V-B SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 9-15-2021 DATE INITIAL PLAN REVIEW COMPLETED: 9-30-2021 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: Office ACTUAL AREA: 7,630 sf STORIES: 1 HEIGHT: not changed OCCUPANT LOAD: 5 1 DATE PLANS RECEIVED BY ESGIL CORPORATION: - PLAN REVIEWER: Erich A. Kuchar, P.E. This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process. please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC202 l-0356 9-30-2021 GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. 2. Plans may be submitted in electronic format, subject to the jurisdiction's approval. If so, they must have restrictions removed from the security settings. Electronic plans with restrictions to markups, printing, or stamping will not be approved. Electronic plans must be submitted back to the jurisdiction's building department and will then be routed to lnterwest. Electronic plans may not be submitted directly to lnterwest. 3. Please provide a response list indicating where each correction item has been addressed on the plans. I.e., specify the plan sheet, note, or detail number, calculation page, etc., where the item is corrected on the plans. 4. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: D Yes D No 5. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. 'If you have any questions regarding these plan review items, please contact lnterwest. Thank you. J Carlsbad CBC202 l-0356 9-30-2021 BUILDING COMMENTS Plan Check Engineer: Erich A. Kuchar, P.E. EXITS Set: I 6. The plans shall designate the number of occupants to be accommodated on every floor, and in all rooms and spaces. Section 107.2.3. Sheet A2.0 is missing occupant counts for most of the offices and open office space. Please show accurate counts for each space as occupant load appears to be over 50. 7. Exit doors shall swing in the direction of exit travel when serving a room containing an occupant load of 50 or more persons or a Group H occupancy. Section 1010.1.2.1. Switch the direction of swing for the double doors leading into the office area from reception waiting area as swinging out towards the building exit. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT-TITLE 24 The following disabled access items are taken from the 2019 edition of California Building Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. REMODELS, ADDITIONS AND REPAIRS When alterations, structural repairs or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the following requirements, per Section 11 B-202.4: • The area of specific alteration, repair or addition must comply as "new" construction. • A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. • The path of travel shall include the existing parking. • Existing toilet and bathing facilities that serve the remodeled area must be shown to comply with all accessibility features. CURB RAMPS 8. The location of the truncated domes on sheet A 1.1 show them on the slopes of the curb ramps which is not allowed and must be moved to the bottom of the ramp and flipped to be parallel in direction as shown on detail 1/AD1 . 9. Show that detectable warnings, 36" deep and extending the full width of the curb ramp, are to be installed for all curb ramps (regardless of slope), per Section 11 B- 705. Only approved DSNAC detectable warning products and directional surfaces shall be installed. Section 11 B-705.3. Update sheet A 1.1 Carlsbad CBC202 l-0356 9 -30-2021 10. Detectable warnings shall be installed in curb ramps with one or two entrance/ exit points that are 6' or 9' wide, respectively. Section 11-B-705.1.2.2. For existing conditions, the truncated domes can be changed to 2'-0" in depth while still maintaining the 3'-0" clear width adjacent. This means the minimum sidewalk must be 5'-0" at access aisles. Update A 1.1 and detail 1 /AD1 . ...... ,., one enfnmc&leKit point ,. 36mln tf.f 38mln y; tl-8 w· ~ ,..., (b) two enltanca/exJt points FIGURE 118-705. f .2.2.2 PARAL.L!L CURB RAMPS 11 . Detectable warnings are not permitted in the required turning spaces, clear floor spaces, landings for doors, pedestrian ramps, access aisles to accessible parking, drop off/ loading zones & stairs. Sections 11 B-304.2, 11 B-305.2, 11 B- 404.2.4.4, 11 B-405.7, 11 B-502.4, 11 B-503.4, 11 B-504.4, and 11 B-705.1.2.2, respectively. ELECTRICAL COMMENTS PLAN REVIEWER: Scott Humphrey Set: I 12. On sheet E201 it appears some of the emergency lighting is absent (not shown) for the south, east & west hallways. I see the photometric which is appropriate. Please clarify. , Carlsbad CBC2021-0356 9-30-2021 Note: If you have any questions regarding this Electrical and Energy plan review list please contact Scott Humphrey at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. END OF DOCUMENT Carlsbad CBC202 l-0356 9-30-2021 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Erich A. Kuchar, P.E. BUILDING ADDRESS: 2776 Gateway Road BUILDING OCCUPANCY: B PLAN CHECK#.: CBC2021-0356 DATE: 9-30-2021 BULDING AREA PORTION (Sq.Fl) FtJI Tl 7630 Air Conditioring Fire Sprinklers TOTAL VALUE .Al risdiction Code cb I 1997 USC Building Permit Fee .i:] l I'll r>I: I 1997 USC Plan Check Fet 11\1 ill: ~ Valuation ~ier By Ordinance Type of Review: P Complete Review r Repetitive Fee .,. ~ Repeats r r r Other r How1y EsG■Fee r Reg. VALUE Mod. r Structural Only Commercial Non-Structural Tl= $2,009.45 x 0.65 = $1,306.14 ($) 354,871 354,871 1 , $1,306.1~ Sheet 1 of 1 OFRCEUIEONLY SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE RECORDl>•---------------1 PLAN CHECK•---------------, BP DATE L L Thetalowllig .,....._,.,....lttllefaclllty'a acttvNIN,lK>TtM ..-.nc p,ojectdNcr1pllotl. rl'!!J,,. :· ~-~~~A~•YWJ~c:tw,r:;~c::~ ~ ~ 00fflldhl~Ploliecltol.~w11t1 Jul'lldictlon p'1l:II' 1o p1an aubmlllal. ~, Rallnfl: ,...,.. ---Footae-(lnducllng J)RlC)(llled project): 1. ~orBlaltingAgenta 5. Of\}aniePel'oK!dN 9. w .... Readtvee 13. CorroeNea 2. Compr-eaMd Gaeea 6. 0>cklwn 10. Ccyogenlcs 1.4. OIMlrHNnh Hazards 3. ~ Liquids 7. PynJphorial 11. Hlghly Toido orTOJdc Mtterillt 15. None ofThMe. '· Fl,mMbleSollds 8. UnatableReactlves 12. Reclloadlvea ='"~~~!!=ie;a.Y:aii~~~ft~~~~ofthe FED ME Rl!QlaED Project Compledo,1 Date: Elcpec:tiad On ofOcx;upn:y. 0 CalAAP .Exempt YES NO (for MW 00l'ISln.K;tion or l'IIITIOdellng prqec:ta) 1, □ I II your bullneulllted on the IVYers&slde of1hlsfon'n? (chect( all ltlatapply). 2.. □ WIii yourbullneu dlepoee of~ Sub9tanceaor MedlcalWae&e In 1111'/amounl? 3. 0 WIii your bullneu .._ or trancle ~ ~ In quw,tiliee c,,,,aferthan or equal to 55 gallons, 500 i § 7. □ • 8. □ pounds end/or 2.00 amicfMt? I WII your bueinell _,.. ot trancle ~ toocir1s In any quanlJly'/ Wlltyour bulirtelS uee.,.. eodllfnG or lrl8fal • undelVrOUnd stoiage 1ank? WIii your bualnees store« trancle Regwtted Sul:lliblnC88 (c.lARP)? Ill WW yourbulll'leu UNOf ilWlal a Hcrardow W... Tri Symn (Tille 22, Miele 10)? liicl WII your~ a:n pelrotlum In ..... « conl8nn at your faclity wllh a k:ltll fadllly alianige capadty equal to or~lhan 1,320 gallons? (Celromlal's Abowgr'ound Petraleum Sl(Qga Ad). k'lillellJ □CalAAPRequlr9Cf .... □ CalARP Complete lnlialll c=~ f!"VJi ~~-'IRICT ~The falowlng queslloM 8'111 lnllended.to ldenllfy the majorlty of air poMon ataga. OIJf ~ mNN98 not by theeeqUNtlone. Some reeid'enltlll projects may be eicempt tom APCO nlQUl1ramenls. If yes • 8'l8Wlll1ICt .._ ctuNlions 1. 2 ors or for ITl0l'e «M•II"~ ~ pfa8le COl'uc:t APCO at aocdoomo¢1'lsdogunty.ca.gov; (868) 588-2850; or 10124 ad GnMt Road, San Diego, CA 92131. YES NO 1. □ l!I WIii 1he p,oJect dllll.vb 100 square feet or more of~ building matertals? 2. □ Iii Wll lt'i'f load aupporting ~ rnembera be l1NJICMld? 3. 0 □ (ANSWER ON. Y IF QUESTION 1 or 2 IS YES) Hal• asbe8tlof survey bNrt perfonned byan lndMdual 1hat has pelAd an EPA-appnwed ~ lnapeclor COUl'N? -4.. 0 0 (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Based on the 9UMtY 1'91Ult9, w11 the project disturt> It'/'/ Nbe11m «MllllirWlg meterW? If yea. a nolfflc8llon may be requir9d at leat 10 WOl1dllg days prior to~ all,Nloe ~ Addlllooaly, • nollllcallon may be AIC(Ulred prior ID ' the removal of a load IUPPOf1lnll slrudlll'lll member(•) regardlela of the pnlMl'ICe of 8ltlelioa; 5. 0 ii Wit the p,oJec:t or NIOCiated ~~emit air con&amll•tts? S.. the rewrN aide of this bm for fyplcal equipment requiring.-. APCO ptrmit. ff yes, conlact APCD pl'lorto the inuenoe of a bullclng pem,it. 6. 0 □ (ANSWER ON. Y IF QUESTION 5 IS YES) Wll 1:he p,oJec:t or auoclated. construc:don equipment be loalled ,._, 1.000 faet of a scnool 1t'8ltothe of my knowledge 4lnd It L i' t Z I Dale FOR OFFlCM. Ute ONI.Y: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: ______________ ~--~---------- ~ ~ I I QEall'l'OlltM)A.JRna-llOlt~ ~FOllt ....... ,._..IKITNOTFOlltOCCWMCY Rl!LEAND FOlltOCCU'M¢\' COUNTY-HMO" APCO COUNTY-MIO APCO COUNTY-HMO APCO • II d A ltamp ln this box a exempts bulinesHs from comptetlug « updaling a Hazardous Materiala Buainesa Plan. other P81 litllog ~ may 'l)ply HM-9171 (9/18) COunty of San Diego· DEH • HazMfous Malerials DIYltlori LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEAL TH -HAZARDOUS MATERIALS DMSION Check all that apply: AUTQMODYE □ 8ellefy'~ Oeo.tYard 0CatWasb 0 Deab11hip Ma1n18nance1Pai 0 Machine Shop 0 Painting □ Radiator Shop 0 Rental Yard EquJl)l'Mnt D Re,pa1r1Pn,vent Maintenance □ Spray Boottt OT~Servaa ow~ CHCMICAL HANDLING □AgrtcuNurat~ D Chemk:81 ~ D Chemlclll ~ □ Coalinga/Adhellve 0 Compr11111d Gl,s ~ □o,y~ □ FlblrglasalReeln AppOcallon □a..Stdon □ lndt.lstrlal Laundry D Laboratoly □ l..abofato,y ~ 0 OIi a,ld Fuel 8Utk Supply 0 P"1Jclde OperatorJDlstrtbu1or CHEMICAL HANDLING □ ~ ~ D Pool $upplles/Malnte D PrlnlinglBlle Printing 0 Road Coellngs 0 SWlnmlng Pool 0 TO>dc Gas Handler □Toxic: Gae~ METAL WORKING □Anodizing □ Chemical Mlling/Elrll'litlg □ Flnlsh-Coalingl 0 Flame Spraying □Foundry □ Machine Shop-Orilll~ □ Metal Plating □ Metal PnappinglChemic Coating 0Prec::iousMelalR8COYlf)' □ Sand BlaliUnglGnndlng □St!IIIF~ 0 Wrought Iron •Manufa.ctt.mg AEROSPACE □ ~ fnduatry D Aircraft Malntananc:e D Alnnft ~ lfSCELLANEQUI □A.phaltPlent a ~IOlogy/R.....-ch D ~ □ ~ □ DllpenNry □ 0tlll" OCo-Genenlllonfllilnt D Dental Cli'lk:/Offlce 0Dl~Centlr D Emergency G411MN11101' D Fraan Food ProcNslng Facllty □ Hazaldoua w-. Hauler □ ~ Home 0LalbotatocyJ8iologlcallab 0 Medal Cllnlc/Ofllol a NIIR!uaOxlde(NOJConfrol Systtim □~ O~Utilt"/ 0 Refrigeration S)'A9ffl D Rock Quarry □-~ □ Teleco,nm(,nlclttione Cell Slte □ V.....-..,Y CllnlclHolpltal □ WoocllFumlb.n ~no □ ~/Didely El,ICTRQNJCS □eJlc:lrot!le~AN«nl>IY D Eledn:lnlc CompolN111ia Mln.dacu1ng D Primct Clrmt Board Manufacuing NOTE: niE ABOVE UST INCLUDES BUSINESSES, WHICH TYPICAU... Y USE. STORE. HANDLE. AHD DISPOSE OF HAZARDOUS SUBSTANCES. AH¥ BUSINESS NOT 1NCLUDEO ON nilS LIST. WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE HAZARt>OUS MATERIALS OMSION (~D) REVIEW OF BUSINESS Pl.ANS. FOR MORE INFORMATION CALL (858) !0!M880. LIST OF AIR POLLUTION CONTROL DISTRICT PERMfT CATEGORES Businesses, which Include any of the followfng operations or equipment, will require deaanoe from the Ak Pollufloo Control Ol8triet. CHEIIICAL 47-~GuSteltllUr'I 32-Add ~. Mlling 3S -can & Coll ~ 44-Evepolalcls, Dryers & Stlll Pl'ocmttg Organic MalillWs 24 -o,y Chemk:al Mbdng & Dargent Spray TOMl"I 35 -Bulk 0ty Chemlcall Storage 55-Chrome ~ TMks CQAJJNGS & OR§MI(; IQ.I.Yim 27 -CoaHng & Painting 37-Pluma/w& Ceramic~ Spray Booths 38 -Paint, Stain & Ink Mfg 27 -Prlntlrlg 27 -Pol)<IMtlr ReelnlFlberglae6 Opendlons IIEJALS 18-MelalMlftlngOeviCM 19 -OI Quenching & Sall Balhl 32-Hot Olp GelYanlzlng 39-~ Metal9 Refining ORGANIC CQMPOUNP IIARKETING CGASOUNE. ETCl 25 -Gasoline & Alcotld &Mt Pienta & Temnlls 25 -tntermedlale Rlluelenl 26-Gnollne & Alcohol FUii Dllpenslng CQMBUSDQN BQCL< MR IINSW. 34-Pllton lntemaf-Combustion Engines 04-HotMpf1811t Beldl P1iln1a 13-8oilel'I & HNters (1 mlllon BTU/hr or large(} 05-RockDfllt 14-lna11111ato11 & CNN,mlories 06-Scnlerllng ~ 15-Bom OUt~ 01-s.i..ct Rock a.,._ Plants 16-Core Ovens 06-eoncre. Bllch. CTB, Concr9III Mbca-1, Moon 20-Gas Tl.llf:IIMs. and Turbkw Teet C... & Stllnda & Sb 48-Landftl find/or DigellllfGas Flal'H 10-Bdck Manufacturing g• J;CTRQNICS 29-Automatcld Soldering "2-Bectn.ncColr,ponemMfg fQQQ 12 -Fish Cennel1es 12-SmokeHouM& 50-Cc6eRoatef'I 35-Bulk Flour & Powenld &Agar Stonige IQLYENIMH 28-Vapor & Cold Deg,N11119 30-Solvent & E,dract Octera 31 -Dry Cleaning 2DIZ 01-Abraalve Eltel1ing Eq&lpment 03-Atpf'81(Roollng ~& T...,_ 48-~ a.no.if Mer11b•1t Mfg 51 -Aqueoua w ... NliutnlllDdon 11 -Tlre~ 17-Bl'alfeDlbollder'I 23-Bulk Grain & Dry Chemlc:al T,...,_ & Stotage 48-RIA>berMbr.n 21 -W... Oilposal & ~ Unb 36-Gmdlng ~& Roome -40-Alpfllllt Plr«enient ...,_ 43-Cefwi1ic Slip ea.ting 41-P.-Proclulng -40-Coolng Towera-R4igJltlallon Only 91 -Fwnlpllon Ope,Mlon& 56-wwrP (1 ,:nao,. gal/day «largar) & Pump Stalion NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AH AIR POLLUTION CONTROL DISTRICT PERMIT. IF THERE ARE AH¥ QUESTIONS, CONTACT THE AIR POUUT10N CONTROL DISTRICT AT (858) 586-2600. HM-9171 (e.'18) eoonty ol s.t Diego-DEH -Hez:ardous Maferlall DM1ion C cityof Carlsbad CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov PURPOSE This checklist is intended to help building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their project. This completed checklist (B-50) must be included with the building permit application. The Carlsbad Municipal Code (CMC) can be referenced during completion of this document by clicking on the provided links to each municipal code section. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool Consultation with a certified Energy Consultant is encouraged to assist in filling out this document. Appropriate certification includes, but is not limited to: Licensed, practicing Architect, Engineer, or Contractor familiar with Energy compliance, IECC/HERS Compliance Specialist, ICC G8 Energy Code Specialist, RESNET HERS rater certified, certified ICC Residential Energy Inspector/Plans Examiner, ICC Commercial Energy Inspector and/or Plans Examiner, ICC CALgreen Inspector/Plans Examiner, or Green Building Residential Plan Examiner. · If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, check N/A and provide an explanation or code section describing the exception. Details on CAP ordinance requirements are available at each section by clicking on the municipal code link provided. The project plans must show all details as stated in the applicable Carlsbad Municipal Code (CMC) and/or Energy Code and Green Code sections. Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: Planning Center Carlsbad T.I. 2776 Gateway Road, Carlsbad, CA 92009 / 213-300-0700 Kirk Moeller/ KM Architects, Inc. 2888 Loker Ave. East, Suite 220, Carlsbad, CA 92010 760-803-8006 Contact Email: kirk@kmarchitectsinc.com Contact information of person completing this checklist (if different than above): Name: Company name/address: Applicant Signature: B-50 Kirk Moeller Contact Phone: 760-803-8006 KM Architects, Inc. Contact Email: kirk@kmarchitectsinc.com '-~-----Date:.--'9=----=1=-5---=2=1'------- Page 1 of 7 Revised 04/21 Use the table below to determine which sections of the Ordinance checklist are applicable to your project. For alterations and additions to existing buildings, attach a Permit Valuation breakdown on a separate sheet. Building Permit Valuation (BPV) $ breakdown _______ _ • □ Rllldentlal D New construction D Additions 111d alterations: D BPV < $60,000 D BPV 2: $60,000 D Electrical service panel upgrade only D BPV 2: $200,000 Ill N01nlldel11111 D New construction D Alterations: l!!!I BPV 2: $200,000 or additions 2: 1,000 square feet D BPV 2: $1,000,000 D 2: 2,000 sq. ft. new roof addition 1. Energy Efficiency A high-rise residential building is 4 or more stories, including a Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use 2A*, 3A*, 1B, 2B, *Includes detached, newly constructed ADU 4A*, 3B,4A NIA NIA All residential additions and alterations 1A,4A 4A 1-2 family dwellings and townhouses with attached garages only. *Multi-family dwellings only where interior finishes are removed 1A, 4A* 1 B, 4A* and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 1 B, 2B, 3B, 4B and 5 1B, 5 1B, 2B, 5 Building alterations of 2: 75% existing gross floor area 2B,5 1B also applies if BPV 2: $200,000 Please refer to Carlsbad Municipal Code (CMC) 18.21.155 and 18.30.190,and the California Green Building Standards Code (CALGreen) for more information. Appropriate details and notes must be placed on the plans according to selections chosen in the design. A. D Residentialadditionoralteration.!:$60,000buildingpennitvaluation. D NIA __________ _ Details of selection chosen below must be placed on the plans referencing CMC □ Exception: Home energy score 2: 7 18.30.190. (attach certification) Year Built Single-family Requirements Multi-family Requirements D Before 1978 Select one option: D Ductsealing □ Attic insulation □Cool roof D Attic insulation D 1978 and later Select one option: D Lighting package □ Water heating Package D Between1978and1991 Select one option: D Ductsealing □ Attic insulation □ Cool roof D 1992 and later Select one option: D Lighting package □ Water heating package Updated 4/16/2021 3 B. Ii] Nonresidentiar new construction or alterations~ $200,000 building permit valuation, or additions~ 1,000 square feet. See CMC 18.21.155and CALGreen Appendix A5 !!I NIA A5.203.1.1 Choose one:□ .1 Outdoorlighting □ .2 Restaurant service water heating (CEC 140.5) D .3 Warehouse dock seal doors. D .4 Daylight design PAFs D .5 Exhaust air heat recovery !!!I N/A A5.203.1.2.1 Choose one: D .95 Energy budget (Projects with indoor lighting OR mechanical) D .90 Energy budget (Projects with indoorlightingANDmechanical) !!!I NIA A5.211.1 ** □ On-site renewable energy: D N/A A5.211.3** □ Green power. (If offered by local utility provider, 50% minimum renewable sources) D N/A A5.21 2.1 □ Elevators and escalators: (Project with more than one elevator or two escalators) D N/A A5.213.1 □ Steel framing: (Provide details on plans for options 1-4 chosen) D N/A ________ _ • Includes hotels/motels and high-rise residential buildings •• For alterations~ $1,000,000BPVandaffecting > 75%existinggross floor area, OR alterations that add 2, 000squarefeetof new roof addition: comply with CMC 18.30.130 (section 2B below) instead. 2. Photovoltaic Systems A. 0 Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1 (c)14 for requirements. If project includes installation of an electric heat pump water heater pursuant to CAP section 3B below (low-rise residential Water Heating), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc* sheets if necessary) Total System Size: kWdc = (CFAx.572) I 1,000 + (1.15 x #d.u.) *Formula calculation 'Mlere CFA = conditional floor area, #du= number of dwellings per plan type If proposed system size is less than calculated size, please explain. kWdc Exception D □ D D B. D Nonresidential new construction or alterations ~$1,000,000 BPV AND affecting ~75% existing floor area, OR addition that increases roof area by ~2,000 square feet Please refer to CMC 18.30.130 when completing this section. *Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: □ Gross Floor Area (GFA)Method GFA: □ If< 10,000s.f. Enter: 5kWdc Min. System Size: □ If ~ 10,000s.f. calculate: 15 kWdcx (GFA/10,000) ** kWdc **Round building size factor to nearest tenth, and round system size to nearest whole number. Updated 4/ 16/202 I 4 □ Time-Dependent Valuation Method AnnualTDVEnergyuse:*** ______ x .80= Min. system size: ______ kWdc ***Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A O Residential and hotel/motel new construction. Refer to CMC 18.30.170 when completing this section. Provide complete details on the plans. D For systems serving individual dwelling units choose one system: D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) D Heat pump water heater AND PV system .3 kWdc larger than required in CMC 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential) D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors D Exception: D For systems serving multiple dwelling units, install a central water-heating system with ALL of thefollowing: D Gas or propane water heating system D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low- rise residential) D Solar water heating system that is either: D .20 solar savings fraction D .15 solar savings fraction, plus drain water heat recovery D Exception: B. 0 Nonresidential new construction. Refer to CMC 18.30.150 when completing this section. Provide complete details on the plans. D Water heating system derives at least 40% of its energy from one of the following (attach documentation): D Solar-thermal D Photovoltaics D Recovered energy D Water heating system is (choose one): D Heat pump water heater D Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction D Exception: It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. Updated 4/16/21 5 4. Electric Vehicle Charging A O Residential New construction and major alterations* Please refer to CMC 18.21.140 when completing this section. D One and two-family residential dwelling or townhouse with attached garage: D One EVSE Ready parking space required D Exception : D Multi-family residential· D Exception · Total Parking Spaces EVSE Spaces Proposed EVSE (10% of total) I Installed (50% of EVSE) I Other "Ready" I Other "Capable" I I l Calculations: Total EVSE spaces= .10 x Total parking spaces proposed (rounded up to nearestwhole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest vtiole number) EVSE other may be "Ready" or "Capable" *Major alterations are: ( 1 )for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation~$60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. *ADU exceptions for EV Ready space (no EV ready space required when): (1) The accessory dwelling unit is located within one-half mile of public transit. (2) The accessory dwelling unit is located within an architecturally and historically significant historic district. (3) The accessory dwelling unit is part of the proposed or existing primary residence or an accessory strudure. (4) When on-street parking permits are required but not offered to the occupant of the accessory dwelling unit. (5) When there is a car share vehicle located within one block of the accessory dwelling unit. B. 0 Nonresidential new construction (includes hotels/motels) □ Exception : ____________ _ Please refer to CMC 18.21.150 when completing this section Total Parking Spaces Proposed EVSE (10% of total) I Installed (50% of EVSE) I Other "Ready" I Other "Capable" I I l Calculation· Refer to the table below· Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces D 0-9 1 1 D 10-25 2 1 D 26-50 4 2 D 51-75 6 3 D 76-100 9 5 □ 101-150 12 6 D 151-200 17 9 D 201 andover 1 0 percent of total 50 percent of Required EV Spaces Calculations: Total EVSE spaces= .1 Ox Total parking spaces proposed (rounded up to nearestwholenumber) EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest vtlole number) EVSE other may be "Ready" or "Capable" Updated 4/16/202 I 6 5. Ill Transportation Demand Management (TOM): Nonresidential ONLY An approved Transportation Demand Management (TOM} Plan is required for all nonresidential projects that meet a threshold of employee-generated AOT. City staff will use the table below based on your submitted plans todeterminewhetheror noryourpermit requires a TOM plan. lfTOM is applicable to your permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details. 7,630 SF/ 1000 x 20 = 153 Employee ADT Acknowledgment: Employee ADT Estimation for Various Commercial Uses Office (all)2 20 Restaurant 11 Retaih 8 Industrial 4 Manufacturing 4 Warehousing 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 1()1hEdition 13 11 4.5 3.5 3 1 2 For all office uses, use SANDAG rate of 20 ADT/1 ,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration sample calculatjons; Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. (8,334 sf/ 1,000 x 4.5) + 8 = 46 Employee ADT I ackno\'Aedge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TOM plan and understand that an approved TOM plan is a condition of permit issuance. ApplicantSignature: Kirk Moeller Date.:_ 9_-1_s_-2_1 __ _ Person other than Applicant to be contacted for TDM compliance (if applicable): Name(Printed): _________________ _ Phone Number: ____ _ Email Address: __________________ _ Updated 4/ 16/202 I 7