Loading...
HomeMy WebLinkAbout2405 COUGER DR; ; CBC2022-0275; PermitBuilding Permit Finaled (city of Carlsbad Commercial Permit Print Date: 11/02/2022 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 2405 COUGAR DR, CARLSBAD, CA 92010-8804 BLDG-Commercial 2090404200 $40,000.00 Work Class: Track#: Lot#: Project#: Plan#: Construction Type; Orig. Plan Check#; Plan Check#: Cogen Description: WEST COAST SELF STORAGE: 45.5KW ROOF MOUNT PV SYSTEM, 100 MODS FEE BUILDING PLAN CHECK Property Owner: NWB CARLSBAD LLC 2405 COUGAR DR CARLSBAD, CA 92010 BUILDING PLAN REVIEW -MINOR PROJECTS (PLN) SB1473 -GREEN BUILDING STATE STANDARDS FEE SOLAR-COMMERCIAL: per kW STRONG MOTION -COMMERCIAL (SMIP) Total Fees: $909.20 Total Payments To Date: $909.20 Permit No: CBC2022-0275 Status: Closed -Fina led Applied: 08/03/2022 Issued: 08/25/2022 Fina led Close Out: 11/02/2022 Final Inspection: 10/26/2022 INSPECTOR: Alvarado, Tony Contractor: SANTA CRUZ WESTSIDE ELECTRIC INC 2656 MISSION ST SANTA CRUZ, CA 95060-5703 (831) 469-8888 Balance Due: AMOUNT $401.70 $98.00 $2.00 $396.30 $11.20 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov { City of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan CheckC&'.:s>Qd:Sl-6,;27 Est. Value PC Deposit Date 'l -3-;;);;J Job Address 2405 Cougar Drive, Carlsbad CA 92010 Suite: APN: 2090404200 ----- Tenant Name#: Lot#: Year Built: 2020 -----------------· ·--------------- Year Built: 2020 Occupancy:_n_la __ Construction Type: __ _ Fire sprinklers(:)YESO NO A/C:OYESONo BRIEF DESCRIPTION OF WORK: installation of ballasted roof-mount photovoltaic solar system. System size: 45.50 kW. Equipment (100) Canadian Solar CS3W-460MS, (1) Chint Power CPS SCA36KTL-DO/US-480 Proiedvaluation:$150,539.oo D Addition/New:. _____________ New SF and Use, __________ New SF and Use _______ SF Deck, _______ SF Patio Cover, SF Other (Specify) ___ _ □Tenant Improvement: _____ SF, _____ SF, Existing Use: _______ Proposed Use: ______ _ Existing Use: Proposed Use: ______ _ Dother: ------------------------------------ PRIMARY APPLICANT Name: Olga Pastuszynska Address: 2656 Mission Street City: Santa Cruz State:._C_A __ .Zip: 95060 Phone: 831.325.5970 Email: olga@sandbarsc.com DESIGN PROFESSIONAL Name: Jeff Ansley Address: 1480 Moraga Road Suite C #229 PROPERTY OWNER Name: NWB Carlsbad LLC Address: 39 Castledown Road City: Pleasanton Phone: 408.836.4543 State: CA Zip:._94_56_6 __ _ Email: stangney@wcselfstorage.com CONTRACTOR OF RECORD Business Name: Santa Cruz Westside Electric, Inc. dba Sandbar Address: 2656 Mission Street City: Moraga State:_CA _ __,Zip: 94556 City: Santa Cruz State: CA Zip: __ 9_5oo_o ____ _ Phone: 510.847.9041 Phone: 831.469.8888 Email: jeff@natronresources.com Email: olga@sandbarsc.com Architect State License: n/a CSLB License#: 846294 Class: C-10 ---------------------·------- Carlsbad Business License# (Required)· • .,,.,.., • .,.,..~a.-, ... ..,.,~,,,=•00 APPLICANT CERT/FICA TION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. _ f ~~~~:~'.:~,'.~~~:,:•bJszynska '" ,m,~::~N: <YfrP,k~•r DATE::.::::::~sboo~,~ REV. 04/22 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I herebyaff irmunder penal tyof per jury that I am I icensed under provisions of Chapter 9 ( commencing with Sect ion 7000) of Division 3 of the Business and Professions Code, and my license is inf ull force and effect. I a/soaffirm under penalty of per jury one of the following declarations (CHOOSE ONE): DI have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. Policy No. _________________________________________ _ -OR- ~I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name: _s_ta_te_c_o_m..:.p_en_s_a_tio_n_ln_s_ur_a_nce_F_un_d ___________ _ Policy No. 9047133-21 Expiration Date: _0_31_01_12_0_2_3 ____________ _ -OR-D Certificate of Exemption: 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code I. lender's Name: ______________________ Lender's Address: _____________________ _ CONTRACTOR CERT/FICA TION; The applicant certifies that all docvments and plans clearly and accurately show aJJ existing and proposed buildings, structures, access roads, and util,ties/utility easements. Arr prapa;ed modifications and/or additions are clearly labeled on the site plan Any potentially existing detail within these plans inconsistent with the sfte plan are not approved for construction and may be required to be altered or removed. The city's opproval of the application is based on the premise that the submitted document> and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roods/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development hove been accurately shown and labeled as weJI as all on-site grading/site preparation. All improvements existing _on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise note . NAME (PRINT): Olga Pastuszynska (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner ot the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner ot property who builds or improves thereon, and who does such · work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he d"1d not build or improve for the purpose of sale). -OR- DJ, as owner of the property, am exclusively contracting with licensed controctors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR· DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: AND, 0 FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors./ understandthatacopyof the applicable law, Section 7044of the Business and Professions Code, is available upon request when thisapplication is submitted or at the following Web site: http:Ilwww.ieginfo.ca.govlca/aw.html. OWNER CERT/FICA TION: The applicant certifies thot oil documents and plans clearly and accurately show all eKisting and proposed buildings, structures, access roods, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved/or construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another,· access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accvrotery shown and labeled as well as all on-site grading/site preparation. Air improvements e,/sling on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. NAME (PRINT): SIGN: __________ DATE: ______ _ Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Suilding@carlsbadca.gov 2 REV. 04/22 Building Permit Inspection History Finaled (city of Carlsbad Permit Type: Work Class: Status: Scheduled Date 10/25/2022 10/26/2022 PERMIT INSPECTION HISTORY' fori ,<=sc2022-021s) BLDG-Commercial Application Date: 08/03/2022 Owner: NWB CARLSBAD LLC Cogen Issue Date: 08/25/2022 Subdivision: PARCEL MAP NO 18059 Closed -Finaled Expiration Date: 04/24/2023 Address: 2405 COUGAR DR IVR Number: 42371 CARLSBAD, CA 92010-8804 Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection 10/25/2022 BLDG-35 Solar Panel Checklist Item 194877-2022 COMMENTS Status Partial Pass Tony Alvarado BLDG-Building Deficiency Progress Inspection-commercial building PV solar inspection-partial pass. 10/26/2022 BLDG-34 Rough Electrical BLDG-Electric Meter Release 195132-2022 195133-2022 Passed Tony Alvarado Passed Tony Alvarado BLDG-Final Inspection 194978-2022 Passed Tony Alvarado Checklist Item BLDG-Structural Final BLDG-Electrical Final COMMENTS October 26, 2022: 1. Commercial building self storage, roof mounted PV solar array per engineered plans and detail specifications -approved. Reinspection Incomplete Passed Yes Complete Complete Complete Passed Yes Yes Wednesday, November 2, 2022 Page 1 of 1 I ... • , r: z A1 CBC2022-0275 2405 COUGAR DR ~S~TE~~~~T ii~~ STORAGE: 45.SKW ROOF MOUNT PV CONSULTING ENGINEERS INC. 2090404200 8/3/2022 CBC2022-0275 6/21/2022 SANDBAR 2119 DELAWARE AVENUE SANTA CRUZ CA 95060 Reference: WCSS Carlsbad, 2405 Cougar Dr, Carlsbad, CA 92010 To Whom It May Concern: The following calculations are for the structural engineering design of the rooftop PV racking and are valid only for the structural information referenced in the stamped plan set. The verification of such info is the responsibility of others. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Limitations Installation of the solar panels must be performed in accordance with manufacturer recom·rnendations. All work performed must be in accordance with accepted industry-wide ·methods and applicable safety standards. The contractor shall notify the consultant should any damage, deterioration, or discrepancies between the as-built condition of the structure and the condition described in this letter be found. The use of solar panel support span tables provided by others is allowed only where the building type, site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables. The design of the solar panel racking (mounts, ballast, rails, etc.) and electrical engineering are out of the scope of this work. Consultant assumes no responsibility for improper installation of the solar array. If you have any questions, do not hesitate to contact. AHZ Consulting Engineers Professional Engineer proiects@ahzengineers.com EXP. 09/30/2023 >-1--0 CONSULTING ENGINE£115 INC. Design Codes and Guidelines; AHZ Consulting Engineers, Inc. www .ahzengineers.com 1. 2019 California Building Code. Job Code: WCSS Carlsbad Page 2 of 10 2. ASCE {2016). "Minimum Design Loads for Buildings and Other Structures. ASCE/SEI Standard 7-16." Design Parameters; Risk Category: II Ground Snow Load (psf): 0 Ultimate Wind Speed ·{mph} = 96. Topographic Factor, kzt = 1.0 Directionality Factor, kd = 0.85 Exposure Category: C Velocity Press Exp Factor, kz = 1.0 Site Class: D ss {g) = 0.958 S1 (g} = 0.351 SDS (g} = 0.767 5D1 {g) = 0.398 SDC: D Ip= 1.5 ap= 1.0 Rp= 1.5 QO== 2.5 . ,. COHSUl TING ENGINEERS INC. Racking System: AHZ Consulting Engineers, Inc. www.ahzengineers.com Job Code: WCSS Carlsbad Page 3 of 10 The proposed racking system is Unirac ballasted system. Per the ballast design report provided on the PV plans, the system is "attached" and positive anchors to the roof decking are required. The contractor must follow the recommended baffast layout by the manufacturer. Average Dead load of PV System= 3.0 psf Total Weight of PV System on Roof= 8698 lbs Attachment Check: Per the ballast design report, the required design capacities of the attachments are: ATTACHMENT TYPE UNlRAC FLASHLOC RM ATTACHMENT CAPACITY UPLIFT 497.1 lbs ATTACHMENT CAPACITY SHEAR 401.6 lbs The proposed attachment details consist of (6) #12 tek screws and the metal deck is 18GA. Therefore: Allowable Uplift Capacity of the Attachment= 6 x132 = 792 lbs OK Allowable Shear Capacity of the Attachment :c: 6 x308::: 1848 lbs OK Roof Framing Check: Per original structural plans, the roof framing consists of (2) back-to-back cold-formed stee C channels at 10'-0" OC spacing. The max span is 10'-0". 3RD FLOOR FRAMING SCHEDULE STYl(: .' S a .::i-lUll OR J0151 ~£CTI◊~ I "" Tr-'.ACK :S~C"Jlaf,,'S 1."-TEfll_.1;1,,, 'HIC·IUIESS: (E:C:AMPLf.: D.DS-4.N "' ~4 ra;li.; I mil -= .J,iM:i ll~Ctl[S) CONSUi.TiN& ENlilNEERS INC. AHZ Consulting Engineers, Inc. www.ahzengineers.com B. DESIGN CRITERIA 1. CODE: 2016 CAUFORNJA BUILDING CODE 2-DEAO LOADS: ROOF = 11 PSF ,ST, 2ND, 3RD .-LOOR = 41 PSF GROUND FLOOR ~ 52 PSF Job Code: WCSS Carlsbad Page 4 of10 2o. FUTURE SOLAR PANEL UNIFORM GRAV,TY LOADS MAY BE OffSET BY DIRECT SUBSTITUTION OF UV( LOADS (lv'.A){IMlJtJ. 12.0 PSF) IN AFFEC'ffD AREAS. lXrERAl LOADS IMPACT mo LOA!) COMBINATION IMPACT TO BE EVALUATED BY ENGINEER OF RECORD FOR THE SOLAR PROJECT. 3_ LIVE LOADS: ROOF = 20 PSF (REDUC!BLE) i'LOOR = 125 PSF (LIGHT STOR..\GE) LOBBIES. CORRIDORS 100 PSF STAIRS = 100 PSF Dead Load Calculations: Existing dead load (per blueprint)= 11 psf Additional dead load due to PV = 3 psf Wind Load Calculations: Ultimate Wind Speed (mph)= 96 Directionality Factor, kd = 0.85 Topographic Fact';)r, kzt = 1.0 Velocity Press Exp Factor, kz = 1.00 Ground Elevation Factor, ke = 1.00 Velocity Pressure, qz (psf) = 20.1 Array Edge Factor, yE = 1.25 Solar Equalization Factor, ya= 0.64 External Pressure Up, GCp_1 = -1.6 External Pressure Up, GCp_2 = -2.15 External Pressure Up, GCp_3 = -2.9 External Pressure Down, GCp = 0.25 Design Pressure Up, p_l (psf) = -25.9 Design Pressure Up, p_2 (psf) = -34.7 Design Pressure Up, p_3 (psf) = -46.9 Design Pressure Down, p (psf) = 16.0 Computer program RISA was used to check the roof framing members for the appliable loads (see attached). As shown attached, the roof framing is adequate and, therefore, no structural upgrade is required. Seismic Check: Existing Weight: Wall Weight (psf) = Tributary Wall Area (ft2) = 50 2800 CONSUL TING ENGINEERS INC:. Additional PV Weight: Weight Increase: AHZ Consulting Engineers, Inc. www.ahzengineers.com Total Wall Weight (lbs) = Roof Weight (psf) = Roof Area (ft2) = Total Roof Weight (lbs) = Total Existing Weight (lbs) = Total Additional PV Weight {lbs) = (Existing W + Additional W}/(Existing W) = 102% Job Code: WCSS Carlsbad Page 5 of 10 140000 11 19500 214500 354500 8698 The increase in weight because of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. CONSULTING ENGINEERS INC. ~ AHZ Consulting Engineers, Inc. www.ahzengineers.com -- Ill IXI J, "' 0 "' "' U) a a ~ 8 Job Code: WCSS Carlsbad Page 6 of 10 ~ <( ..... 'Sl" (') -m " N ~ El 'U N ~ oi :;j .... .... u ' Q) iJ:, :::c: C Cl} ::, u r/) -., s: "C .a II) .:: Ill l) "' (I) ~ CDNSUn!NG ENlilNEERS INC. -~ •''1~~0 lJ •••M~'II .-~ i:Jl AHZ Consulting Engineers, Inc. www.ahzengineers.com - N ~ ~ Job Code: WCSS Carlsbad Page 7 of 10 ~ <( co :1: (") 1ii ,, N t1 ~ 1J ., N {al (1) ,:: ., N ,r" u ' Q) f/l :.! C 0, ;:J ~ rn --, "Cl (U ..c <I) ~ Cl) ti) 0 ~ .,, ~ $ .l!! <>. ID 6-~~ ~do TI+ co Zn ci o~--~o_g a-U(,) o ~-' --8 U) i E TI:::, ~~i coNSULTIHG ENGINEERS me. AHZ Consulting Engineers, Inc. www .ahzengineers.com Job Code: WCSS Carlsbad Page 8 of 10 :!: < U) -.i-(') 'tij 'D N ~ a. 'D .. N ., .. CJ) 1i l"l ·'""' 0 . a> ., ::IC'. C 0) ::, ~ !I) -, AHZ Consulting Engineers, Inc. www.ahzengineers.com CDNSIILTINli ENlilNEEl!S INC. IIIRISA Company Designer Job Number Model Name WCSS Carl5_bad Joint Coordinates and Temperatures Joint Boundary Conditions Member Primary Data Member Distributed Loads (BLC 1 : D) ---~(!J_ .... --1°-,,-□-----l Y_[ftl __ D 0 Y kiln Reaction Reaction Job Code: WCSS Carlsbad Page 9 of 10 I June 19, 2022 3:48AM Checlted By: __ ---_T_emp_[I'] __ 0 0 Rolalion ,Mad I 1 Member Label Dlreclil>n start MQgnitUdt(lb/ft End Magnitudl!j!b/11 f ksQ Slart Locatk> End Location[lt%J rnacwe M1 I Y -140 I -140 I o I o I Active Member Distributed Loads (BLC 2 : Wup) I 1 Member Lfm•l Dir,wtion stan Magnilu®[lbill End MagMude(lb/ft F ls•IJ start Locatjo . End LQcatior(ll.'lLJ lnactt,,e M1 I Y · 260 / 260 r O I O ) Active Member Distributed Loads (BLC 3 : Wdown) Member 1 M1 Y -160 Lo,ad Combinatio~s . ·1 ··o.c~~t-PJ~:wr~~l:'6J. .. Jl8&!,; -~1i~aa}~i\i8LCl:a .. ·1BU.: .'!--7BLC~ -~!!LT_., .. BJ.CF"-~j-L!l!I,, B.LCE'!--. 6L7F-•.-., _c.L_ D + 0.6W f Ve C 1 : 1 3 0.6 I I ___ __,_I___,__,_ __ .___.,__.,___,__..,____, Member AISI S100-16: ASD Cold Formed Steel Code Checks 2 2, M1 2-eoos250-e ... : 0.439 I 5 0.114 . 10 RISA-2D Version 19.0.0 [C:\ ... \ ... \ ... \ ... \WCSS Carlsbad.r2d] Page 1 CONSULTINli ENlilNEE!IS INC. IIIRISA Company Designer Job Number Model Name Beam Deflections RISA-2D Version 19.0.0 AHZ Consulting Engineers, Inc. www.ahzengineers.com WCSS Catl-,bad [C:\ ... \ ... \ ... \ ... \WCSS Carlsbad.r2d] Job Code: WCSS Carlsbad Page 10 of 10 June 19, 2022 3:48AM Cheeked l:ly: __ Page2 Building Permit Finaled Revision Permit Print Date: 11/02/2022 Job Address: 2405 COUGAR DR, CARLSBAD, CA 92010-8804 (city of Carlsbad Permit No: PREV2022-0109 Status: Closed -Finaled Permit Type: BLDG-Permit Revision Work Class: Commercial Permit Revision Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: 2090404200 Track#: $0.00 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: CBC2022-0275 Plan Check#: Code Edition: 2019 Sprinkled: Project Title: Applied: 09/19/2022 Issued: 10/17/2022 Finaled Close Out: 11/02/2022 Final Inspection: INSPECTOR: Description: WEST COAST SELF STORAGE: (REVISION TO EQUIPMENT) 46 KW ROOF MOUNT PV SYSTEM, 93 MODS FEE BUILDING PLAN CHECK FEE (manual) Total Fees: $120.00 Building Division Property Owner: NWB CARLSBAD LLC 2405 COUGAR DR CARLSBAD, CA 92010 Total Payments To Date: $120.00 Contractor: SANTA CRUZ WESTSIDE ELECTRIC INC 2656 MISSION ST SANTA CRUZ, CA 95060-5703 (831) 469-8888 Balance Due: AMOUNT $120.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov {'Cityof Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 442-339-2719 www.carlsbadca.gov 0 .. . CBC222-0275 ng1nal Plan Check Number ________ Plan Revision Number Project Address 2405 Cougar Drive, Carlsbad CA 92010 . "' . '~\·.:.,_..\ General Scope of Revision/Deferred Submittal: _e_q_u_1_p_r,;.c-__ e_n_t_c_h_a_n_g_e ________ _ CONTACT INFORMATION: Name Olga Pastuszynska Phone 831. 325.5970 ________ Fax.,__ _______ _ Address 2656 Mission Street City Santa Cruz Zip 95060 Email Address olga@sandbarsc.com Original plans pr~pared by an architect or engineer, revisions must be signed & stamped by that ~- 1. Elements revised: Iii Plans D Calculations D Soils D Energy D Other ,,,,,.. 4. 5. 6. 2. Describe revisions in detail (100) Canadian Solar CS3W-460MS (460W) (460W) changed to (93) Trina Solar TSM-495DEG18MC.20(1I) (495 W) ' Does this revision, in any way, alter the exterior of the project? 0 Yes Does this revision add ANY new floor area(s)? D Yes Does this revision afflrr.~~:e-.c! D Yes 0 No liJ No 7. Is this a complete s Date I 3. .--List pa~~IS) ~h~za, rev1sron rs sh n 1,2,3,5,6,aT 13,14,15,16,20 21,22 Ii] No 1635 Faraday Avenue. Carlsbad, CA 92008 Ph: 442-339-2719 Fax: 7 60-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov Building Permit Finaled Revision Permit Print Date: 11/02/2022 Job Address: 2405 COUGAR DR, CARLSBAD, CA 92010-8804 (city of Carlsbad Permit No: PREV2022-0122 Status: Closed -Fina led Permit Type: BLDG-Permit Revision 2090404200 Work Class: Commercial Permit Revision Parcel #: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: $D.00 Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: CBC2022-0275 Plan Check#: Description: WEST COAST SELF STORAGE: 45.SKW ROOF MOUNT PV SYSTEM, 100 MODS FEE BUILDING PLAN CHECK FEE (manual) Total Fees: $120.00 Building Division Property Owner: NWB CARLSBAD LLC 2405 COUGAR DR CARLSBAD, CA 92010 Total Payments To Date: $120.00 Applied: 10/17/2022 Issued: 10/24/2022 Fina led Close Out: 11/02/2022 Final Inspection: INSPECTOR: Contractor: SANTA CRUZ WESTSIDE ELECTRIC INC 2656 MISSION ST SANTA CRUZ, CA 95060-5703 (831) 469-8888 Balance Due: AMOUNT $120.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560f I www.carlsbadca.gov { City of Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 442-339-2719 www .ca rlsbadca .gov Original Plan Check Number CBC2022-02?5 Plan Revision Number A's.."52.\J ?f()ld~() t-2::? Project Address 2405 Cougar Drive, Carlsbad CA 92010 General Scope of Revision/Deferred Submittal: array was shifted away from roof hatch CONTACT INFORMATION: Name Olga Pastuszynska Phone 831.325.5970 ________ Fax,__ _______ _ Address 2656 Mission Street City Santa Cruz Zip 95060 Email Address olga@sandbarsc.com Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: Ii] Plans D Calculations D Soils D Energy D Other 2. 3. Describe revisions in detail List page/s) where each revision is shown array layout was shifted away from the roof hatch 4. Does this revision, in any way, alter the exterior of the project? D Yes Ii] No 5. Does this revision add ANY new floor area(s)? D Yes Ii] No 6. Does this revision affect any fire related issues? D Yes D No 7. ls this a complete set? D Yes [ii No 2S'Signature 0~ /Jcu:tzu.,.~· Date 10.17.2022 1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 442-339-2719 Fax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov