HomeMy WebLinkAboutCT 79-08; WALTON CONDOS; Site PlanI/
I
i
s.
l ' . o.
F.;.oors: see plan for material.
1 I --t'j I.IL ~1.0 H-~
flat (kitchen and
Except.kitchen and
base 1/2" x 1-5/8 11 streamline wood.
.:>oars' interior l-3/8" hollow core, exterior 1-3/4 11 , garage
~-3/8'' soiid core self closing, wardrobe doors 1-1/8" heights
as shown on plan.
w.,,.ndows a~uminum frame, sliding w/screen. See~plan and elevation.
W~ndows to have·no dimension less than 22-.
Cas.=i..ng ~/2" x 1--5/8" streamline wood at doors.
:or.crete for footings shall
uf 2,SOG ~s. at 28 days and
) ::,a.ct.s sa:i.C, 4 parts of 111
l.uar. 7-:.../2 gallons of water
have a m1n1mun: compressive strength
snall ce composed of 1 part cement,
maxirawn s1 ze rock, and not .. ·~more
per sack of cemer. t.
tf,.,,.CA
Slabs on grade shall be at least 3-1/2 ''
~4" nominal, •
·:· .rea tee. Wove. A ... -:... foundation plates or s.1. 1-:...s ar.C: sj,_eepers
ur. ci concrci:.e slao, wt,1.cr. is l.L d ..... rect contact with earth,
a .. c. s ......... s whicf. rest on concrete or masonry foundations, and
wooc. :io ... st.s closer tnan 18", or wood girders or supports
c .... oser tna.r. 12" to·-the ground shall be pressure treated wood
or foundation grade redwood.
Ar.caor Bo ... 't.S and Footi'ng S:i.lls. Al.:.. footing sills shall t.ave
~~ ....... .oear:..,.c; on the footing wall or si.ab and shall be bolted
~_c, 't.he foundat:i.on w1.t.u -:,../2'' x 10•· bo.:..ts embedded at least 7"
Crete Or rel.. nforced masor.rs/""'or 15" into unreinforced ~ :. r..v ttie con J.
srouted masonry. Bolts shal~ ~e spaced not to exceed 6' on
cer.t..er wl. tt. Dolts not over 12" from cut end of sills.
___ : r, ter ;or wa:..l ;,la tes PTDF
v.c. and max. 6" from end
w/ ramset pins SP 3320 at 32"
and 10" from splice.
.., ...un..:,e r •
sr.a ... :... oe,..No.
and oeams 5"
or oetter.
joists, rafters, beams, and post.s 2" to 4" ti1ick
2 Grade Douglas Fir-Larch or better. A:1 posts
and thicker sha~: be No. l Grade Douglas Fir-Larch
111a .... Bracing. Every exterior wood· stud wa.1:.. and mair. cross
•Jartition shall be braced at each end and at least every 25 I . 1 feet of length with 1 x 4 diagonal·let-in braces or equiva ent.
Cross.;;Bridging. Floor joists; and rafters more-,than ,12" in
cieptr, and spanning more. than 8 feet. si1all be supported
~aterally by bridging at intervals not exceeding 8 feet.
1
I ;_ 9.
20.
21.
22.
' 25.
' 26.
2 !:, •
30.
,,
fi;•.-,:·-~
"
A-4)
Provide blocking at ends and supports· of rafters more than 8 11
in depth.
Provide solid blocking at ridge line and at exterior walls on
trussed roofs.
Double Joists. Floor joists shall be doubled-under bearing
partitions running parallel with the joists •
Rafter Purlin braces to be not less than 45-degrees to the
horizontal.
Rafter Ties. Rafter ties shall be spaced not more than 4 feet
on center where rafters and ceiling joists are not parallel.
Provide 1/2" minimum clearance between top
partitions and bottom chord of trusses.
plate of interior
Provide double top plate with minimum•48" lap splice.
Nailing will be in compliance with Table 2S~P.
Fire blocking shall
Also for horizontal
draft opening.
be provided for walls over 10•~0• in height.
shafts 10~-0" o.c., and for any concealed
/i-!) .~
Studs. In one-or two-3tory buildings, studs ,f;(?_:t\··exterior wallS
and interior bearing walls shal·l not be less th:~p~f'2 x 4 at 16"
o.c. Sti.,:ds fe:e ia.i::e:t:=ie:t:= iAGnbo;iring pi1rtitions ''i?Ja11 'be 2 x 3
at , 8 e e Studs 2 11 -4" j;:.hick and 2 ''· -4" wide dnd not more
thar. S feet long shall be "stud grade" Douglas Fir""'Larch or
better when supporting not-more than one floor and a roof.
Wood Siding. All wood siding shall be placed over an approved,
weatherproofing barrier.
F~ashing
shai~ be
Around Openings. Every opening in any exterior wall
flashed with sheet metal or waterproof building paper.
j
we8 p Screed. A weep screed shall be provided for all exterior _
stud walls finished on the exterior with stucco at the foundation!
p.:..ate line. 1
Shower Enclosures. Shower walls roust be finished to a height
of 6 feet with a smooth hard, nonabsorbent surface. -.Doors
anG panels of shower and bathtub enclosures and windows with
s.-.:i.: less than S'-0 11 above the floor shall be fully temper7d,
.aminated safety glass or·approved shatter-resistant plastic.
G.:..azing. Glass in all unframed glass doors must be ful):y
tempered. Approved safety glazing must be used in sliding
.including fixed glass panels-which are part of such u~its.
.~anufactured window and door units are labeled as meeting
ANSI standards for air infiltration.
doors 1
:G. :::v:::~:~:c:~n:x::,:::sw:~~s:t supports of floor,:oists, and. [ 32 _ water heaters to have P&T relief valve drain to exterior, fuel·'
shut off valve, & 4" type '1 B" vent.
water closet width clearance-shall be 30" and front clearance 24"
min.
•' 33. -...:.. --··-·
:i
,-~~e·••·•.···· ·.• ~rA%Q~'a;
·'-"' .:·
'.,"~._,·-: ;./
,~~e.-t.c.:, ,x ,, :~ i;._,.. ,:B ,. 1
PRINTED ON DIETERICH-POST CLEARPRINT 1000H
:
35.
36.
37.
39.
40.
EXhaust fans ~ustprovide min. of 8 air changes per hour •.
Undercut door to room.
Bathtub 5 degrees one piece fiberglass over green board.\J.o.~.
ea.al.es'\:ieli.
Insulation at all.habitable area to be 4n, R 19 Batts at
ceiling and 3-l/2", R ll Batts at exterior walls.
Reefing
Furnace to have shut off v·alve and 4" type "B 11 vent. Refer
to heating layouts for additional information, Combustion
air from outside.
Exterior swinging doors to be weatherstripped and labeled
as complying with ANSI standards.
E~ectric Meter Enclosure. Contact San Diego Gas & Electric
Company, Customer Extension Planning Department, for meter
location. ,All wiring must comply with the National Electrica}
Code (l97 5 Editionl.
-'"I '.::!,
' _. ·-,-~·.:K-7
\.-'mi:~,;, : __ -4
...---\
\
I
\.. 't°II ,,A.C, <
r',t,.'i.·'~O ',
\
I
I
' I
I l ' ~ \ , "0 t-'lft? ?, I ~" -.--1 ·-·-
--I
I
\
.,.,e, ,
t,.,1,. ~c1~ ,,,_ M e,1,. t;i,, .J.;, Uf.l ! -;-t-i.<, .1
M-"r✓: C4"~
h,>-~ t?I ee,.o ~,:,tJ,if-f 1 ~,
I
REVISIONS
i
DATE
SCALE
DRAWN
JOB
SHEET
A-\
OF SHEETS
BY
'
I
.,
'
. ' I
''
·,,
.,
'
I
)
/