Loading...
HomeMy WebLinkAbout2715 ABEDUL ST; ; CBR2022-1363; PermitBuilding Permit Finaled Residential Permit Print Date: 03/09/2023 Job Address: 2715 ABEDUL ST, CARLSBAD, CA 92009-5310 Permit Type: BLDG-Residential Work Class: P/M/E Parcel#: Valuation: Occupancy Group: #of Dwelling Units: 2153502300 Track#: $0.00 Lot#: Project#: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Occupant Load: Plan Check#: Code Edition: Sprinkled: Project Title: Description: RABABY: INSTALL MULTIP ORT MINI SPLIT W/ 3 INDOOR UNITS (E-REVIEW) Applicant: THE RIGHT CHOICE HEATING AND AIR INC TOMER PERETZ 5351 GEYSER AVE TARZANA, CA 91356-3308 (818) 435-7560 FEE PLUMBING, MECHANICAL & ELECTRICAL PERMITS Total Fees : $193.00 Total Payments To Date: $193.00 Permit No: Status: {city of Carlsbad CBR2022-1363 Closed -Finaled Applied: 04/20/2022 Issued : 04/22/2022 Finaled Close Out: 03/09/2023 Final Inspection: 11/04/2022 INSPECTOR: Alvarado, Tony Kersch, Tim Contractor: THE RIGHT CHOICE HEATING AND AIR INC 9825 INDEPENDENCE AVE CHATSWORTH, CA 91311-4320 (818) 435-7560 Balance Due: AMOUNT $193.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov ; Cifyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION 8-1 Plan Check ________ _ Est. Va lue PC Deposit Date JobAddress d-4'(6 ~ '3\-:· Unit: _____ .APN: __________ _ CT/Project #: _________________ Lot #: ____ Vear Built: ________ _ BRIEF 0EscRrPT10N oF woRK: \C'b:'0,\\ Vf\u.~ po-r..+ m't{)l ?fi·,k". ou+-&.c:0r ~ooo ITTu 3 Wo()r ( x.. ';;} Op)o ~ 1 \ ,,eooo B:s:µ, □ New SF : Living SF, ____ Deck SF, ___ Patio SF, ____ Garage SF __ _ Is this to create an Accessory Dwelling Unit? O Y O N New Fireplace? O YO N, if yes how many? ___ _ D Remodel: _____ SF of affected area Is the area a conversion or change of use? O YO N □ Pool/Spa:. _____ SF Additional Gas or Electrical Features? ____________ _ □Solar: ___ KW, ___ Modules, Mounted:QRoofOGround, Tilt: ('.)YON, RMA: OY ON, Battery:OYO N, Panel Upgrade: OvON Other: PRIMARY APPLICANT PROPERTY OWNER Name:ft?Q'Y::C ;t.bee.-\---==b-Name: :\Q('?f\:t t\_ L,~¢-P-A. ½o...lov) Address: 53.:::i7 Oa::!?:Y ~ kv-€-. Address: a3:1-s ~A LA\ 5\::: . I City: TM~ State: C ~ Zip: ot r:,s:ee City: C.&:&\6\co-.& Statel fr Zip: g :?:oo'.3 Phone: r£~-';-\ ~ S-3::Tu {) Phone: ~O -5 3 ~-'d \ 4 \ Email: \'{)A,\\ fil\\.;,un~cJ11..0t cgV\'0/lC..C..OW' Email: \Q\.o(},~'\ ® 'J;W:'O:+\ · tMV\ DESIGN PROFESSIONAL CONTRACTOR OF RECORD Name: _______________ BusinessName: :fh.e. Q.,,:~ G½Q~l.€ t,\eAf,~i)A;,r Address: Address: "\'Q;}S \ Q~~Ra:JU' p.-y.g - City: _______ State: ___ Zip:_____ CityCh:s\;,;wo:6:½ State: (~ Zip:_°}_.__l~ ___ \_( __ _ Phone: Phone: 9-',1\'7'2::: 435-::::t§lpO Email: Email: \,'X)Q.. ~ \ @)::--k&, ~ e¥'-\-(..\,t.b.'.c....<'.... \,\\.J&c.. · ~ Architect State License: CSLB License#: qee,OY,:::j:-Class: <2"d-b; 13 Carlsbad Business License# (Required): I?, L£J.5{ 3'-\3Ci f}S APPLICANT CERT/FICA TION: I certify that I have read the application and state that the above information is correct and that the information of the plans is accurate. I ,,,., ro _,, _ ,11 c;::_""""' ,Ms1,~ /om ,e/WmJW b,H<P,g ro,nmctl~~??: 5,i' NAME{PRINT): \c:m.e-r ?~~ SIG~=;....-:,-DATE: ~-15<2::~ 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov REV. 04/22 .. ····----·------------- THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: lherebyaffirmunderpenaltyofperjurythatlamlicensedunderprovisionsofChapter9(commencingwithSection7000)ofDivision3 of the Business and Professions Code, and my license is in full force and effect. I also affirm under penal tyof perjury one of the following declarations (CHOOSE ONE): DI have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. PolicyNo. ____________________________________________ _ -OR- ial have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: "£a::r< Y\~ ~ \ ('f,u { Av"Le (~L:{ Policy No. l--5' !;31? 9-Z>~ 5 '.P;, Expiration Date: ~3---u=-----',g.=---3..__ _______ 1 -OR- D Certificate of Exemption:! certify that in the performance of the work for which this permit is issued,! shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued {Sec. 3097 (i) Civil Code). Lender's Name: _______________________ lender's Address: _______________________ _ CONTRACTOR CERT/FICA TION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. n ~ ,1. NAME (PRINT): \ D:{l'Q,C y-?-("£+==b-SIGNATURE:c---:-< 2 __:::;:, DATE:_y-__ -__ 1 ..... 9: __ -0--o--_· __ _ Note: If the person signing above is an authorized agent for the contractor rovide a letter of authorization on contractor letterhead. (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). -OR-DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 forth is reason: AND, D FORM 8-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below l acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of t he improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted or at the following Web site: http:l l www.leginfo.ca.gov/ ca law.html. OWNER CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as aJI on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. NAME (PRINT}: __________ SIGN: _________ DATE: _____ _ above is an authorized a ent for the ro e owner include form B-62 si ned b owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov 2 REV. 04/22 Building Permit Inspection History Finaled {city of Carlsbad PERMIT INSPECTION HISTORY for (CBR2022-1363) Permit Type: BLDG-Residential Application Date: 04/20/2022 Owner: ATR PALOMAR MOBIL Work Class: P/M/E Issue Date: 04/22/2022 Subdivision: LA COSTA MEADOWS #3 Status: Closed -Finaled Expiration Date: 05/03/2023 Address: 2715 ABEDUL ST IVRNumber: 40114 CARLSBAD, CA 92009-5310 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 05/26/2022 05/26/2022 BLDG-43 Air 183573-2022 Passed Tim Kersch Complete Cond./Furnace Set Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Final Inspection 183574-2022 Failed Tim Kersch Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes 06/06/2022 06/06/2022 BLDG-44 184251-2022 Cancelled Tony Alvarado Reinspection Incomplete Rough/Ducts/Dampers Checklist Item COMMENTS Passed BLDG-Building Deficiency June 6, 2022: No 1. Reached out to owners representative Lisa, regarding reinspection for new mini split system, due to previous failure in HVAC contractor installation practices of new air conditioning mini split system installed. 2. Owner will reschedule at later date on a Thursday to accommodate owner and contractor representative schedule. 06/16/2022 06/16/2022 BLDG-44 185039-2022 Failed Tony Alvarado Reinspection Incomplete Rough/Ducts/Dampers Friday, November 4, 2022 Page 1 of 5 PERMIT INSPECTION HISTORY for (CBR2022-1363) Permit Type: BLDG-Residential Work Class: P/M/E Status: Closed -Finaled Application Date: 04/20/2022 Owner: ATR PALOMAR MOBIL Issue Date: 04/22/2022 Subdivision: LA COSTA MEADOWS #3 Expiration Date: 05/03/2023 IVRNumber: 40114 Address: 2715 ABEDUL ST CARLSBAD, CA 92009-5310 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS June 16, 2022: 1. Reinspection required due to mechanical HVAC electrical equipment in attic and coil systems. Packaged units. 2. required metal leak-proof pans under attic units-required. 3. 30" x 30" minimal working platforms in front of each hvac units in attic locations required. 4. Total of (3) qty. electrical HVAC attic units require working platforms. 5. Owner is requesting catwalk to be installed, 1/2" or 5/8" inch plywood catwalk 18" wide up to 22" wide, from attic access ceiling opening to all mechanical HVAC/equipment units. 6. Owners requesting mechanical code sections call-outs requirements for all the following items:leak pans, catwalk, safety switch installation and location, size of mechanical HVAC metal pans. 7. Rest of (3)-attic mechanical HVAC electrical units replaced, scope of work-OK. June 6, 2022: 1. Reached out to owners representative Lisa, regarding reinspection for new mini split system, due to previous failure in HVAC contractor installation practices of new air conditioning mini split system installed. 2. Owner will reschedule at later date on a Thursday to accommodate owner and contractor representative schedule. 10/21/2022 10/21/2022 BLDG-44 194653-2022 Failed Tony Alvarado Rough/Ducts/Dampers Friday, November 4, 2022 Passed No No Reinspection Incomplete Page 2 of 5 PERMIT INSPECTION HISTORY for (CBR2022-1363) Application Date: 04/20/2022 Owner: ATR PALOMAR MOBIL Permit Type: BLDG-Residential Work Class: P/M/E Issue Date: 04/22/2022 Subdivision: LA COSTA MEADOWS #3 Status: Scheduled Date 11/04/2022 Closed -Finaled Expiration Date: 05/03/2023 IVRNumber: 40114 Address: 2715 ABEDUL ST CARLSBAD, CA 92009-5310 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS June 6, 2022: 1. Reached out to owners representative Lisa, regarding reinspection for new mini split system, due to previous failure in HVAC contractor installation practices of new air conditioning mini split system installed. 2. Owner will reschedule at later date on a Thursday to accommodate owner and contractor representative schedule. June 16, 2022: 1. Reinspection required due to mechanical HVAC electrical equipment in attic and coil systems. Packaged units. 2. required metal leak-proof pans under attic units-required. 3. 30" x 30" minimal working platforms in front of each hvac units in attic locations required. 4. Total of (3) qty. electrical HVAC attic units require working platforms. 5. Owner is requesting catwalk to be installed, 1/2" or 5/8" inch plywood catwalk 18" wide up to 22" wide, from attic access ceiling opening to all mechanical HVAC/equipment units. 6. Owners requesting mechanical code sections call-outs requirements for all the following items:leak pans, catwalk, safety switch installation and location, size of mechanical HVAC metal pans. 7. Rest of (3)-attic mechanical HVAC electrical units replaced, scope of work-OK. October 21, 2022: (mechanical inspection failed). 1. Attic location, (3)-new condenser unit installed, new drip pans/metal drip pans too small, and do not cover entire condensate unit dimensions in order to help reduce water damage, if any future leaks. 2. Two new Condensate lines, required to be supported more efficiently with metal strap, located at two locations in attic area. 3. Informed owner Lisa Rababy, Reinspection required. 4. The rest of the new (3)-mechanical units installed in attic location, scope of work appears to be-OK. 11/04/2022 BLDG-44 195843-2022 Passed Tony Alvarado Rough/Ducts/Dampers Passed No No No Complete Friday, November 4, 2022 Page 3 of 5 PERMIT INSPECTION HISTORY for (CBR2022-1363) Permit Type: BLDG-Residential Work Class: P/M/E Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item Application Date: 04/20/2022 Owner: ATR PALOMAR MOBIL Issue Date: 04/22/2022 Subdivision: LA COSTA MEADOWS #3 Expiration Date: 05/03/2023 IVRNumber: Inspection No. COMMENTS 40114 Inspection Status Address: 2715 ABEDUL ST CARLSBAD, CA 92009-5310 Primary Inspector Reinspection Inspection Passed BLDG-Building Deficiency November 4, 2022: Yes BLDG-Final Inspection Friday, November 4, 2022 (Final mechanical inspection approved). 1. 2nd. Level Attic location, (3)-new condenser mechanical units installed, with new drip pans/metal drip pans do not cover entire condensate unit perimeter dimensions, in order for drip metal pans to collect and help reduce water damage to building structure. 2. The new attic mechanical unit-coil locations, therefore Will be protected if there is any sort of mechanical coil unit water failure in the future. The 3-new metal drip pans encompass the entire condenser unit coil system locations, in order to collect any possible water runoff. 3. The Building inspector and homeowner Lisa Rababy were informed regarding the three new metal drip pans installed will be adequate and provide secondary water leak protection, if there is a future mechanical unit water leak failure, per contractor representative Ruben who addressed and completed all final correction issues on behalf of the the Right Choice company. 4. Two new Condensate lines, required to be supported more efficiently with straps, located at two locations in attic area-approved. 5. Informed owner Lisa Rababy, Final mechanical inspection -approved .. 6. The rest of the new (3)-mechanical units installed in attic location, scope of work appears to be-OK. 195969-2022 Passed Tony Alvarado Complete Page 4of 5 PERMIT INSPECTION HISTORY for (CBR2022-1363) Permit Type: BLDG-Residential Work Class: P/M/E Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item BLDG-Mechanical Final BLDG-Structural Final Friday, November 4, 2022 Application Date: 04/20/2022 Owner: ATR PALOMAR MOBIL Issue Date: 04/22/2022 Subdivision: LA COSTA MEADOWS #3 Expiration Date: 05/03/2023 IVRNumber: 40114 Address: 2715 ABEDUL ST CARLSBAD, CA 92009-5310 Inspection No. Inspection Status Primary Inspector Reinspection Inspection COMMENTS November 4, 2022: (Final mechanical inspection approved). 1. 2nd. Level Attic location, (3)-new condenser mechanical units installed, with new drip pans/metal drip pans do not cover entire condensate unit perimeter dimensions, in order for drip metal pans to collect and help reduce water damage to building structure. 2. The new attic mechanical unit-coil locations, therefore Will be protected if there is any sort of mechanical coil unit water failure in the future. The 3-new metal drip pans encompass the entire condenser unit coil system locations, in order to collect any possible water runoff. 3. The Building inspector and homeowner Lisa Rababy were informed regarding the three new metal drip pans installed will be adequate and provide secondary water leak protection, if there is a future mechanical unit water leak failure, per contractor representative Ruben who addressed and completed all final correction issues on behalf of the the Right Choice company. 4. Two new Condensate lines, required to be supported more efficiently with straps, located at two locations in attic area-approved. 5. Informed owner Lisa Rababy, Final mechanical inspection -approved .. 6. The rest of the new (3)-mechanical units installed in attic location, scope of work appears to be-OK. Passed Yes Yes Page 5 of 5