HomeMy WebLinkAbout2711 EL RASTRO LN; ; CBR2021-3604; PermitBuilding Permit Finaled Residential Permit Print Date: 09/19/2022 Job Address: PermitType: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 2711 EL RASTRO LN, CARLSBAD, CA 92009-9110 BLDG-Residential Work Class: 2551060400 Track#: $86,275.50 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Addition Description: WALSETH; (496 SF) ADDITION TWO NEW BEDROOMS AND 1 BATH FEE BUILDING PLAN CHECK BUILDING PLAN REVIEW-MINOR PROJECTS (LDE) BUILDING PLAN REVIEW-MINOR PROJECTS (PLN) SB1473-GREEN BUILDING STATE STANDARDS FEE SFD & DUPLEXES STRONG MOTION -RESIDENTIAL (SMIP) SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-Medium Total Fees: $2,559.52 Total Payments To Date: $2,559.52 (city of Carlsbad Permit No: CBR2021-3604 Status: Closed -Fina led Applied: 11/30/2021 Issued: 02/28/2022 Finaled Close Out: 07/26/2022 Final Inspection: 07/26/2022 INSPECTOR: Alvarado, Tony Balance Due: AMOUNT $755.30 $194.00 $98.00 $4.00 $1,162.00 $11.22 $271.00 $64.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction.11 You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560f I www.carlsbadca.gov ( Cicyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan CheckCBR.2QZ.l -31,0'f Est. Value I ~}.r7£@ PC DeposiiJf 7.5J ,.JV Date /.(-a0-2O2...I Job Address2711 El Rastro Lane. Carlsbad, CA 92009 Unit: _____ ,APN:255-106-04-00 CT/Project #: __________________ Lot #:_2_90 ___ Year Built: _________ _ Fire Sprinklers:OE,@No Air Conditioning:@YEsQNo Electrical Panel Upgrade0vEs0No BRIEF DESCRIPTION OF WORK:509 SF single level addition consisting of 2 new bedrooms and 1 bathroom. Ej New SF :509 Living SF,2114 Deck SF, 0 Patio SF, 0 Garage SF _48_6 __ Is this to create an Accessory Dwelling Unit?QY{!)N New Fireplace? QY(!}N, if yes how many? __ _ D Remodel: _____ SF of affected area Is the area a conversion or change of use?Qv QN 0 Pool/Spa: ____ .SF Additional Gas or Electrical Features? Standard outlets & lights 0Solar: ___ KW, ___ .Modules, Mounted:OoofO,round, Tilt:O vO N, RMA:QvQN, Battery: CJ( OJ, Panel Upgrade: QY ~ D Re roof: _________________________________ _ D Plumbing/Mechanical/Electrical 0 Only: Other: PRIMARY APPLICANT Name: Justin Walseth Address: 2711 El Rastro Lane City: Carlsbad State:_C_A __ ,Zip: 92009 Phone:858.531.5699 Email:iwalseth@cresa.com PROPERTY OWNER Name:Justin Walseth Address:2711 El Rastro Lane City:Carlsbad State:CA Zip:_9_20_0_9 __ _ Phone: 858.531.5699 Email: jwalseth@cresa.com DESIGN PROFESSIONAL CONTRACTOR OF RECORD Name: Ben Liu Business Name: ________________ _ Address: 11373 Broadview Dr Address: __________________ _ City: Moorpark State:_C_A __ .Zip: 93021 City: _______ .State: __ -'Zip: ______ _ Phone:805.529.4975 Phone: __________________ _ Email:benliu@cadbuilt.com Email: ___________________ _ Architect State License: ___________ CSLB License #: _______ Class: ______ _ Carlsbad Busine s License# (Required): _______ _ APPLICANT CERTIFICATION: I certify that I have read the application a state t at t e abo e information is correct and that the information on the plans isaccurate. I agree to comply with all City rdi e a d e lows relating to building construction. NAME (PRINT): JuStin Walseth SIGN:i..::,_-1-61-==--......a:,__ __ DATE: fl{7°t(-Z0 'l( 1635 Faraday Ave Carlsbad, CA 92008 Email: Building@carlsbadca.gov REV. 07/21 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR ()KA PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION F RM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I herebyaffirmunder penalty of perjury that I am licensedunderprovi · nsof Chapter9 / commencing with Section 7000)of Division] of the Businessand Professions Code, and my license is in full fore ndeffect. I also affirm under penalty of perjury one of the following declarations /CHOOSE ONE): Q1 have and will maintain a certificate of consent to self-insure for work s' compensation provided by Section 3700 of the labor Code, for the performance of the work which this permit is issued. PoficyNo. ________ ~£_ ____________________________ _ -OR- Q! have and will maintain worker's compensation, as required Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. y workers' compensation insurance carrier and policy numb are: Insurance Company Name: _____________________ _ Policy No. Expiration Date: _______________ _ -OR-O certificate of Exemption: I certify that in the perfor. a nee of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of Calif nia. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000 0, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGE CY IF ANY: I hereby affirm that there is a constr}Jcti Lender's Name: N I A lending agency for the performance of the work this permit is issue')JS Lender's Address:---~---/'--'-~--------------' CONTRACTOR CERT/FICA TION: I certify that I have read the application and state the information on the plans is accurate. I agree to comply with all City ordinanc construction. -OR (OPTION B): OWNER-BUILDER DECLARATION: e information is correct and that ws relating to building I hereby affirm that I am exempt from Contractor's License Law for the following reason: {!) I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR-O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR-O I am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: AND, [i] FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors. / understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted orat the following Web site: http: I /www.leginfo.ca.gov/calaw.html. OWNER CERT/FICA TION: I certify that I have read the application and state tha th information on the plans isaccurate. I agree to comply with all City ordin construction. NAME (PRINT): Justin Walseth 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8S58 2 above i rmation is correct and that the e laws relating ta building Email: Building@carlsbadca.gov REV. 07/21 {city of Carlsbad OWNER-BUILDER ACKNOWLEDGEMENT FORM B-61 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov OWNER-BUILDER ACKNOWLEDGMENT FORM Pursuant ta State of California Health and Safety Cade Section 19825-19829 To: Property Owner An application for construction permit(s) has been submitted in your name listing you as the owner--builder of the property located at: Site Address 2711 El Raslro Ln, Carlsbad, CA 92009 The City of Carlsbad ("City") is providing you with this Owner-Builder Acknowledgment and Verification form to inform you of the responsibilities and the possible risks associated with typical construction activities issued in your name as the Owner-Builder. The City will not issue a construction permit until you have read and initialed your understanding of each provision in the Property Owner Acknowledgment section below and sign the form. An agent of the owner cannot execute this notice unless you, the property owner, complete the Owner's Authorized Agent form and it is accepted by the City of Carlsbad. INSTRUCTIONS: Please read and initial each statement below to acknowledge your understanding and verification of this information by signature at the bottom of the form. These are very important construction related acknowledgments designed to inform the property owner of his/her obligations related to the requested permit activities. I. JW I understand a frequent practice of unlicensed contractors is to have the property owner obtain an "Owner Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner--Bullder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed contractor and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner···Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. II. JW I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed contractor to assume this responsibility. Ill. JW I understand as an "Owner---Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own. 1V. JW I understand contractors are required by law to be licensed and bonded in Californla and to list their license numbers on permits and contracts. V. JW I understand if I employ or otherwise engage any persons, other than California licensed contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. REV. 08/20 Owner-Builder Acknowledgement Continued VI. JW I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation far each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. V11. JW 1 understand under California Contractors' State license Law, an Owner--Builder who builds single-· family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building contractor. Vlll. JW I understand as an Owner•-Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) which result from any latent construction defects in the workmanship or materials. IX. JW I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1··.S0Q .. •321---CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. X. JW I am aware of and consent to an Owner---Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the following address: 2711 El Rastro Ln, Carlsbad, CA 92009 XI. JW I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner--Builders as well as employers. XII. JW I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information l have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractor's State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner- Builder and wish to hire contractors, you will be responsible for verifying whether or not those contractors are properly licensed and the status of their workers' compensation coverage. Before a building permit can be issued, this form must be completed, signed by the property owner and returned to the City of Carlsbad Building Division. I declare under penalty of perjury that I have read ond understand all of the information provided on this form and that my responses, including my authority ta sign this form, is true and correct. I am aware that I have the option to consult with /ego/ counsel prior to signing this form, and I have either (1) consulted with legal counsel prior to signing this form or (2) have waived this right in signing this form without the advice of legal counsel. Justin Walseth Property Owner Name (PRINT) Date 2 REV.08/20 ~ , PERMIT INSPEC:TION ~I§~ORY for (q~R2021-3604) Permit Type: BLDG-Residential Work Class: Addition Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final BLDG-Electrical Final Monday, September 19, 2022 Application Date: 11/30/2021 Owner: TRUST JB AND CB LIVING TRUST 03-17-17 Issue Date: 02/28/2022 Subdivision: CARLSBAD TCT#73-18 UNIT#04 Expiration Date: 10/31/2022 IVR Number: 37332 Address: 2711 EL RASTRO LN CARLSBAD, CA 92009-9110 Inspection No. Inspection Primary Inspector Reinspection Inspection Status COMMENTS July 25, 2022 1. Spoke to contractor representative Justin, regarding room addition final inspection. 2. Contractor required B-59 waste management form to completed and filed in city records. 3. Contractor rep.-not ready with final City Of Carlsbad documentation Passed Yes Yes Yes No Yes Page 4 of 4 PERMIT INSPECTION HISTORY for (CBR2021-3604) Permit Type: BLDG-Residential Work Class: Addition Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item Application Date: 11/30/2021 Issue Date: 02/28/2022 Expiration Date: 10/31/2022 IVR Number: 37332 Inspection No, COMMENTS Inspection Status Owner: TRUST JB AND CB LIVING TRUST 03-17-17 Subdivision: CARLSBAD TCT#73-18 UNIT#04 Address: 2711 EL RASTRO LN CARLSBAD, CA 92009-9110 Primary Inspector Reinspection Inspection Passed BLDG-Building Deficiency July 25, 2022: No BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 07126/2022 07/26/2022 BLDG-Final Inspection Monday, September 19, 2022 1. Spoke to contractor representative Justin, regarding room addition final inspection. 2. Contractor required 8-59 waste management form to completed and filed in city records. 3. Contractor rep.-not ready with final City Of Carlsbad documentation July 25, 2022: 1. Spoke to contractor representative Justin, regarding room addition final inspection. 2. Contractor required B-59 waste management form to completed and filed in city records. 3. Contractor rep.-not ready with final City Of Carlsbad documentation July 25, 2022: 1 . Spoke to contractor representative Justin, regarding room addition final inspection. 2. Contractor required B-59 waste management form to completed and filed in city records. 3. Contractor rep.-not ready with final City Of Carlsbad documentation July 25, 2022: 1. Spoke to contractor representative Justin, regarding room addition final inspection. 2. Contractor required B-59 waste management form to completed and filed in city records. 3. Contractor rep.-not ready with final City Of Carlsbad documentation July 25, 2022: 1. Spoke to contractor representative Justin, regarding room addition final inspection. 2. Contractor required B-59 waste management form to completed and filed in city records. 3. Contractor rep.-not ready with final City Of Carlsbad documentation 187701-2022 Passed Tony Alvarado No No No No Complete Page 3 of 4 ""' '' ""'""'"" " { fu/iiJL '.fu/i ;J( • RERMIT INSPECTION,HISTO,¥ for {CBR2021-3604) Permit Type: BLDG-Residential Application Date: 11/30/2021 Owner: TRUST JB AND CB LIVING TRUST 03-17-17 Work Class: Addition Issue Date: 02/28/2022 Subdivision: CARLSBAD TCT#73-18 UNIT#04 Status: Closed -Finaled Expiration Date: 10/31/2022 Address: 2711 EL RASTRO LN IVR Number: 37332 CARLSBAD, CA 92009-9110 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 04/29/2022 04/29/2022 BLDG-18 Exterior 181799-2022 Passed Tony Alvarado Complete Lath/Drywall BLDG-84 Rough 181798-2022 Passed Tony Alvarado Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 05/04/2022 05/04/2022 BLDG-16 Insulation 182029-2022 Passed Tony Alvarado Complete 0712512022 07/25/2022 BLDG-Final Inspection 187564-2022 Failed Tony Alvarado Reinspection Incomplete Monday, September 19, 2022 Page 2 of 4 Building Permit Inspection History Finaled ( City of Carlsbad PERMIT INSPECTION HISTORY for (CBR2O21-36O4) Permit Type: BLDG-Residential Application Date: 11/30/2021 Owner: TRUST JB AND CB LIVING TRUST 03-17-17 Work Class: Addition Issue Date: 02/28/2022 Subdivision: CARLSBAD TCT#73-18 UNIT#04 Status: Closed -Finaled Expiration Date: 10/31/2022 IVR Number: 37332 Address: 2711 EL RASTRO LN CARLSBAD, CA 92009-9110 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date 03/08/2022 03/08/2022 BLDG-SW-Pre-Con Checklist Item 177952-2022 COMMENTS Status Passed Tony Alvarado BLDG-Building Deficiency March 8, 2022: 03/14/2022 03/14/2022 BLDG-21 Underground/Underflo or Plumbing Checklist Item 1. Preconstruction/Stormwater requirements and guidelines-approved. 178371-2022 Passed Tony Alvarado COMMENTS BLDG-Building Deficiency March 14, 2022: 03/22/2022 03/22/2022 BLDG-11 Foundation/Ftg/Piers (Rebar) BLDG-12 Steel/Bond Beam 04/15/2022 04/15/2022 BLDG-13 Shear Panels/HD (ok to wrap) Checklist Item 1. Underground plumbing lines w~ste and vent lines, underwater leak test, with 10'feet of head pressure test-approved. 178815-2022 Passed Tony Alvarado 178951-2022 Passed Tony Alvarado 180768-2022 Passed Tony Alvarado COMMENTS BLDG-Building Deficiency April 15, 2022: 1. New roof, plywood roof sheeting; type, size, and method of attachment with metal connectors end approved.-approved. 2. New exterior shear-wall panels plywood; type, size, and method of attachment, scope of work-approved Per plan. BLDG-15 Roof/ReRoof (Patio) 180767-2022 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency Monday, September 19, 2022 COMMENTS April 15, 2022: 1. New roof, plywood roof sheeting; type, size, and method of attachment with metal connectors end approved.-approved. 2. New exterior shear-wall panels plywood; type, size, and method of attachment, scope of work-approved Per plan. Complete Passed Yes Complete Passed Yes Complete Complete Complete Passed Yes Complete Passed Yes Page 1 of 4 INTE.RWESl DATE: 2/17/2022 JURISDICTION: City of Carlsbad PLAN CHECK#.: CB-CBR2021-3604.RC1 PROJECT ADDRESS: 2711 El Rastro Lane PROJECT NAME: Walseth-Res-Addtion SET: II □ APPLICANT □ JURIS. ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. ~ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Justin Walseth ~ lnterwest staff did not advise the applicant that the plan check has been completed. D lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Justin Walseth Telephone#: 858-531-5699 Date contacted: (by: ) Email: jwalseth@cresa.com Mail Telephone Fax In Person 0 REMARKS: By: Ellaine Esteller lnterwest Enclosures: 2/7/2022 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 • lW INTERWEST DATE: 12/13/2021 JURISDICTION: City of Carlsbad PLAN CHECK#.: CB-CBR2021-3604 PROJECT ADDRESS: 2711 El Rastro Lane PROJECT NAME: Walseth-Res-Addtion SET: I □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Justin Walseth D lnterwest staff did not advise the applicant that the plan check has been completed. ~ lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Justin Walseth Telephone#: 858-531-5699 Date contacted: (by: ) Email: jwalseth@cresa.com Mail Telephone Fax In Person 0 REMARKS: By: Ellaine Esteller lnterwest Enclosures: 12/02/2021 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CB-CBR2021-3604 JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2711 El Rastro Lane FLOOR AREA: 509 SF Addition REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 12/13/2021 FOREWORD (PLEASE READ): STORIES: 1 HEIGHT: 8' Ceiling DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/02/2021 PLAN REVIEWER: Ellaine Esteller This plan review is limited to the technical requirements contained in the California Residential Code, California Building Code, California Plumbing Code, California Mechanical Code, California I Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2019 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2019 CRC, 2019 CBC, 2019 CPC, 2019 CMC and 2019 CEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2019 California Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy} where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK#.: CB-CBR2021-3604 PREPARED BY: Ellaine Esteller BUILDING ADDRESS: 2711 El Rastro Lane BUILDING OCCUPANCY: R-3 BUILDING I AREA I Valuation PORTION (Sq.Fl) Multiplier Residential Additi< 509 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB By Ordinance 1997 UBC Buildin Permit Fee • ' 1997 UBC Plan Check Fee • : Type of Review: Complete Review D Repetitive Fee ...,. Repeats Comments: □ Other □ Hourly EaGil Fee DATE: 12/13/2021 Reg. VALUE ($) Mod. D Structural Only $755.301 Sheet of ------------------------------------------- PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. 1. Provide item-by-item responses on an 8-1/2-inch by 11-inch sheet(s) clearly and specifically indicating where and how each correction item has been addressed (vague responses, such as "Done" or "See plans," are unacceptable) 2. Indicate on the Title Sheet of the plans the name of the person responsible for the preparation of the plans. Section R106.1.1. 3. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 4. Provide a statement on the Title Sheet of the plans stating that the "project will comply with the following building codes", and list the following codes: 2019 California Residential Code (CRC) and/or 2019 California Building Code (CBC) as applicable 2019 California Green Building Standards Code (CalGreen) 2019 California Electrical Code (CEC) 2019 California Mechanical Code (CMC) 2019 California Plumbing Code (CPC) 2019 California Fire Code (CFC) 2019 California Building Energy Efficiency Standards (CBEES) Section R 106.1. 5. Provide a sheet index on the coversheet that is coordinated with plans. Please include the structural sheets on the sheet index. 6. Please adjust the scales of the plans to reflect the true scale. The plans appear to have 3/32" = 1' scale. FIRE PROTECTION 7. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. 8. Show locations of permanently wired smoke alarms with battery backup, per Section R314: a) Inside each bedroom. b) Outside each separate sleeping area in the immediate vicinity of the bedrooms. c) On each story, including basements. d) Such smoke alarm locations shall comply with the following: i) They shall be not less than 3' from the door opening of a bathroom. ii) They shall be at least 20' from a cooking appliance. iii) They shall be at least 3' from supply registers of heating/cooling systems. iv) They shall be at least 3' from the tip of the blade of a ceiling- mounted fan. ♦ NOTE: When more than one smoke alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 9. In dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), show the locations of permanently wired carbon monoxide alarms with battery backup, per Section R315: a) Outside each separate sleeping area in the immediate vicinity of the bedrooms. b) On each story, including basements. c) Where a fuel-burning appliance is installed in a bedroom or its attached bathroom, a carbon monoxide alarm shall be installed within the bedroom. ♦ NOTE: When more than one carbon monoxide alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. GENERAL RESIDENTIAL REQUIREMENTS 10. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: a) Glazing adjacent to a door where the bottom exposed edge of the glazing is less than 60" above the walking surface. and it meets either of the following conditions: i) Where the glazing is within 24" of either side of the door in the plane of the door in a closed position. ii) Where the glazing is on a wall less than 180 degrees from the plane of the door in a closed position and within 24" of the hinge side of an in-swinging door. Exception: Glazing that is adjacent to the fixed panel of patio doors. b) Glazing in the walls/doors facing or containing bathtubs, showers, hot tubs, spas, whirlpools, saunas, steam rooms and indoor/outdoor swimming pools where the bottom exposed edge of the glazing is less than 60" above the standing surface. Exception: Glazing that is more than 60", measured horizontally, from the water's edge of a bathtub, hot tub, spa, whirlpool or swimming pool. See the figure below. SG SG < Plan view SG = Safely glazing required Measurements are to exposed glazing SG 8G SG <6010. Section view ROOFS/DECKS/BALCONIES <60in. Floor 11 . Specify roof underlayment and layers of material to be used. Note ICC listing report on plans. 12. Please provide the updated ICC approval number or equal for the boral roofing material. 13. Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters). The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 40% (but not more than 50%) of the required vent is located no more than 3' below the ridge) and remaining vents located at the lower third of the of the attic space. Show on the plans the area required and area provided. Section R806.2. a) When using a radiant barrier, California energy design affects the attic ventilation area requirement: If using the Prescriptive method for energy compliance, then the attic vent area must be at the 1 /150 area: If using the Performance method, either the 150 or 300 areas may be used, as documented on the energy forms. Section RA4.2.1. 14. Enclosed rafter spaces do not require venting if the following specific insulation design is used, per Sections R806.5/EM3.9.6: ♦ If the insulation is air-permeable and it is installed directly below the roof sheathing with rigid board or sheet insulation with a minimum R-5 value installed above the roof sheathing. (or) ♦ If the insulation is air-impermeable and it is in direct contact with the underside of the roof sheathing. ( or) • If two layers of insulation are installed below the roof sheathing: An air- impermeable layer in direct contact with the underside of the roof sheathing and an additional layer of air permeable insulation installed directly under the air- impermeable insulation. ♦ In climate zones 3-15, air permeable insulation installed as part of one of the previous insulation assemblies in unvented attics must comply with section R806.5.5.2 15. If eave vents are to be installed, insulation shall not block the free flow of air. A minimum of 1" of air space shall be provided between the insulation and the roof sheathing. To accommodate the thickness of insulation plus the required 1" clearance, member sizes may have to be increased for rafter-ceiling joists. Section R806.3. 16. Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with 1/16" minimum to¼" maximum openings. Section R806.1. 17. Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area (if over 30 sq. ft.), shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section R807.1. FOUNDATION REQUIREMENTS 18. Provide a copy of the project soil report. The report shall include foundation design recommendations based on the engineer's findings and shall comply with Section R401.4. 19. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). 20. Note on plans that surface water will drain away from building and show drainage pattern. The grade shall fall a minimum of 6" within the first 10 feet. Section R401.3 a) Exception: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains or swales shall be constructed to ensure drainage away from the structure. Impervious surfaces within 10 feet of the building foundation shall be sloped not less than 2 percent away from the building. STRUCTURAL 21. Please clarify if Beam No.3 of the structural calculations is being used in the on the project. Was not able to locate the beam on the plans. 22. Detail uplift resistance of rafters per CRC Table R802.11 at supporting wall assemblies. 23. Provide strapping to connect the existing walls to the new proposed walls for lateral support. 24. Please clarify if there is to be Cal-Fill over the new entrance of the home, as shown on the roof framing plans on Sheet S4. There shows no Cal-Fill on building elevation on Sheet A4. Specify roof slope of the Cal-Fill. MECHANICAL 25. Show on the plans the location, type and size (Btu's) of all heating and cooling appliances or systems. 26. Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 68 degrees F at a location 3 feet above the floor and 2 feet from exterior walls in all habitable rooms. Show basis for compliance. CRC 303.10. 27. Detail the dryer exhaust duct design from the dryer to the exterior. The maximum length is 14 feet with a maximum of two 90-degree elbows or provide the manufacturer's duct length specification description on the plans: Include the dryer specifications (manufacturer, model, and fuel type) as well as the duct description (size and type). CMC Section 504.4.2.1. ELECTRICAL 28. Please provide a complete electrical plan detailing the location of all proposed or relocated outlets and lighting fixtures. Please coordinate all symbols shows on the electrical plan with an electrical legend. 29. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52. 30. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 31. 32. 33. 34. a) Tamper resistant receptacles for all locations described in 210.52 and 550.13.(i.e. all receptacles in a dwelling). b) Weather resistant type for receptacles installed in damp or wet locations (outside). 406.4(0)(6). c) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors, within 6' of a sink, etc. For a single-family dwelling unit (and for each unit of a duplex), show that at least one receptacle outlet accessible at grade level will be installed outdoors at the front and back of the dwelling. CEC Article 210.52(E). This receptacle must be GFCI protected. Per CEC Article 210.11 (C)3, note on the plans that bathroom circuiting shall be either: a) b) A 20-ampere circuit dedicated to each bathroom, or At least one 20 ampere circuit supplying only bathroom receptacle outlets. Show on the plans a wall receptacle within 36" of each lavatory in the bathroom. CEC 210.52(0). Show at least one wall switch-controlled lighting outlet to be installed in every habitable room; in bathrooms, hallways, stairways, attached garages, and detached garages with electric power; and at the exterior side of outdoor entrances or exits. At interior stairways show 3-way switching for lighting outlets at each floor level where there are six or more steps. CEC Article 210.70. PLUMBING 35. Show water heater size (1 st hour rating), type, and location on plans. Note: For both new dwellings and additions the Energy Standards (150.0(n)) requires a gas input rating of 200,000 Btu for both tank and instantaneous gas water heaters. (Also) Provide a gas piping design for the gas system. 36. Show the shower stall can accommodate a 30" circle and has a minimum floor area of 1,024 sq. in. CPC Section 408.6. 37. Dimension on the plans the 30" clear width required for the water closet compartment and the (minimum) 24" clearance required in front of the water closet. CPC 402.5. 38. Provide a note on the plans: The control valves in showers, tub/showers, bathtubs, and bidets must be pressure balanced or thermostatic mixing valves. CPC Sections 408, 409, 410. 39. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8 GPM of flow. CPC Sections 407, 408, 411, 412. 40. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407. RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the Green Building Standards Code and must be enforced by the local building official. The following mandatory requirements for residential construction must be included on your plans. CGC Section 101.3. The Standards apply to newly constructed residential buildings, along with additions/alterations that increase the building's conditioned area, volume or size. CGC Section 301.1.1. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. 41. Storm water drainage/retention during construction. Note on the plans: Projects which disturb less than one acre of soil shall manage storm water drainage during construction by one of the following: A. Retention basins. B. Where storm water is conveyed to a public drainage system, water shall be filtered by use of a barrier system, wattle or other approved method. CGC Section 4.106.2. 42. Grading and paving. Note on the plans that site grading or drainage system will manage all surface water flows to keep water from entering buildings (swales, water collection, French drains, etc.). CGC Section 4.106.3. Exception: Additions not altering the drainage path. 43. Indoor water use. Show compliance with the following table, per CGC Section 4.303.1. FIXTURE FLOW RATES FIXTURE TYPE MAXIMUM FLOW RATE Water closets 1.28 gallons/flush Urinals (wall-mounted) 0.125 gallon/flush Urinals (others) 0.5 gallon/flush Showerheads 1.8 gpm @80 psi Lavatory faucets 1.2 gpm @ 60 psi 1 Kitchen faucets 1.8 gpm@ 60 psi Metering faucets 0.20 gallons per cycle 1. Lavatory faucets shall not have a flow rate less than 0.8 gpm at 20 psi. 44. Note on the plans that when a shower is provided with multiple shower heads, the sum of flow to all the heads shall not exceed 1.8 gpm @ 80 psi, or the shower shall be designed so that only one head is on at a time. CGC Section 4.303.1.3.2. 45. Note on the plans that landscape irrigation water use shall have weather or soil-based controllers. CGC Section 4.304.1. 46. Recycling. Note on the plans that a minimum of 65% of construction waste is to be recycled. CGC Section 4.408.1. 47. Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan, per CGC Section 4.408.2. 48. Operation and maintenance manual. Note on the plans that the builder is to provide an operation manual (containing information for maintaining appliances, etc.) for the owner at the time of final inspection. CGC Section 4.410.1. 49. Note on the plans that the gas fireplace(s) shall be a direct-vent sealed- combustion type. Woodstove or pellet stoves must be US EPA Phase II rated appliances. CGC Section 4.503.1. 50. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC Section 4.504.1. 51. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC Section 4.504.2. 52. Interior moisture control. Note on the plans that concrete slabs will be provided with a capillary break. CGC Section 4.505.2.1. 53. Interior moisture control. Note on the plans that the moisture content of wood shall not exceed 19% before it is enclosed in construction. The moisture content needs to be certified by one of 3 methods specified. Building materials with visible signs of water damage should not be used in construction. The moisture content must be determined by the contractor by one of the methods listed in CGC Section 4.505.3. 54. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star rated, vented directly to the outside and controlled by a humidistat CGC 4.506.1. 55. Heating and air-conditioning system design. Heating and air conditioning systems shall be sized, designed and have their equipment selected using the following methods: (Support documentation required at application submittal) 4.507.2. a) Establish heat loss and heat gain values according to ANSI/ACCA Manual J-2016, ASHRAE handbooks or other equivalent methods. b) Size duct systems according to ANSI/ACCA 1 Manual D -2016, ASH RAE handbooks or other equivalent methods. c) Select heating and cooling equipment according to ANSI/ACCA 3 Manual S -2014 or other equivalent methods. Exception: Use of alternate design temperatures necessary to ensure the systems function are acceptable 56. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. ENERGY CONSERVATION 57. Mandatory minimum insulation specifications: (Ceilings: R-22), Exterior walls: 2 X 4 exterior walls: R-13, 2 X 6 exterior walls: R-19) and raised floors: R-19. a) Note: These are minimum values; actual requirements depend upon the project specific energy design (Prescriptive or Performance). ES 150.0(a-d) 58. If there is installation of an instantaneous water heater, Instantaneous water heaters shall have isolation valves on both the cold and the hot water piping leaving the water heater complete with hose bibs or other fittings on each valve for flushing the water heater when the valves are closed. ES 110.3 59. All domestic hot water piping to have the following minimum insulation installed: ½" pipe (1/2" insulation);¾" pipe (1" insulation); 1" to 1-½" pipe (1-½" insulation). CPC 609.11 & ES 150.0U) 60. Additionally, the ½" hot water pipe to the kitchen sink, and the cold-water pipe within 5' of the water heater both require 1" minimum insulation. ES 150.OU) Residential Energy Lighting Requirements: ES 150.0(k) 61. 62. 63. 64. 65. All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A. a) b) Luminaries must have a label certified for airtight construction. Light sources that are not marked "JAS-2019-E" shall not be installed in enclosed luminaires. ES 150.0(k) In bathrooms, garages, laundry rooms, and utility rooms at least one luminaire shall be controlled by a vacancy sensor. Dimmers or vacancy sensors shall control all LED style luminaires. Two exceptions: Fixtures installed in hallways or (closets under 70 square feet). Recessed can light fixtures shall be IC listed, air-tight labeled, and not be equipped with a standard medium base screw shell lamp holder. ES 150.0(k) SFD outdoor lighting fixtures that are attached to a building are required to be high efficacy, be manually on/off switch controlled, and have both motion sensor and photocell control. See ES 150.0(k) 3 for additional control options. Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2 66. Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the exterior. A bathroom is defined "as a room with a bathtub, shower, or spa or some similar source of moisture". 67. Residential bathroom exhaust fans shall be energy star rated and shall be control by a humidistat capable of an adjustment between 50 and 80% humidity. CalGreen 4.506.1. Exception: Control by a humidistat is not required if the bathroom exhaust fan is also the dwelling whole house ventilation. Prescriptive Additions: See Section 150.2(a) through 150c) for additions and alterations. a) Additions 5. 700 sq/ft: i) May use existing size wall framing for wall extensions but with R 15 (2X4) and R21 (2X6). ii) Must be provided with radiant barrier for Climate Zones 2-15. iii) Fenestration: a) 700 to 401 sq/ft: Maximum allowed glazing area is 120 sq/fl or 25% of the addition floor area b) Addition 5. 400 sq/ft Maximum allowed fenestration is 75 sq/ft or 30% of the addition floor area c) In CZ 2, 4, and 6-16 the maximum west facing fenestration is 60 sq/ft. or less and shall also comply with either 1 or 2 below: (1) For additions that are 700 square feet or less but greater than 400 square feet, the maximum allowed fenestration area limit is the greater of 120 square feet or 25 percent of the conditioned floor area of the addition; or (2) For additions that are 400 square feet or less, the maximum allowed fenestration area is the greater of 75 square feet or 30 percent of the conditioned floor area of the addition. MISCELLANEOUS 68. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 69. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ellaine Esteller at lnterwest. Thank you. • VLACHOS ENGINEERING 887 Patriot Dr. Suite G, Moorpark, CA 93021 OFFICE: (805) 552-9550 CELL:818-515-7233 STRUCTURAL CALCULATIONS ADDITION/REMODEL FOR: WALSETH RESIDENCE 2711 EL RATRO LANE CARLSBAD,CA JOB 21-1140 OCTOBER 18, 2021 REV. JANUARY 20, 2022 ON 'q" ONO '<!"0 ON <D --*" 0£2- ..-N M l!"l I ~ ~ N 0 N ~ cc (.) TABLE OF CONTENTS DESIGN INFORMATION 1-6 BEAM GRAVITY CALCULATIONS 7-8 SEISMIC/WIND DESIGN VALUES 9-11 FOUNDATION PAD CALCULATION 12 WIND DESIGN 13 SEISMIC DESIGN 14-15 SHEAR WALL CALCULATIONS 16 01/20/2022 Page 1 of 16 PROJECT: 21-1140 VLACHOS ENGINEERING 530 E. Los Angeles Ave. #115355, Moorpark, CA 93021 PHONE (818) 515-7233 FAX (805) 552-0347 EMAIL: manny@vlachosengmeenng.com OWNER: ADDRESS: ARCH: CADB ENGINEER: M. VLA CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO LOADS: Roof: Roofing = 3 Floor: Fin. Floor= Wall: Framing= Sheathing= Rafters= Insulation = Clg. Joists= Ceiling= Misc.= Dead Load= Live Load= Total Load= GENERAL NOTES: 3 Sheathing = 3 Fir. Joists - 1 ilin = 3 3 0 36 psf 1. Structure shall conform to the 2019 edition of the California Building Code (CBC) Sheating= Exterior Finish = Total Loads = 4 3 9 16 2. CONCRETE: Shall be 28 day strength f c = 2500 psi and shall be constructed in accordance with Chapter 19 of the CBC. 10/9/21 3. CONCRETE MASONRY UNITS: Shall be grade "N" (normal weight) units conforming to A.S.T.M. Designation C90 and shall be laid in accordance with Chapter 21 of the CBC. Masonry i$-designed for 50 / 100% of the allowable stresses. Continuous inspection is/ is not required. 4. REINFORCING STEEL: Shall be intermediate grade, deformed bars conforming to A.S.T.M. A-615, Grade 60, Splices to be 48 bar diameters minimum, no less than 24". 5. LUMBER: All lumber shall be Grade Marked, No. 2 Douglas Fir minimum except as noted on plans. All posts to be No. 1 Douglas Fir. Wood Structural Panels shall be 5-ply STRUCT I plywood (PSl-83) or STRUCT I OSB (PS2-92). Construction shall be in accordance with Chapter 23 of the CBC. 6. STRUCTURAL STEEL: Shall conform to A.S.T.M. A-36&A-572 and be erected in accordance with Chapter 22 of the CBC. 7. SOIL: NONE Soil Bearing Value: __ 1,500 PSF Report No. ___ N/A~---Equiv. Fluid Pressure: ___ N/A, ___ _ Date: ______ Expansive Rating: ___ N/A, _____ _ It is recommended that all building projects have a current Soils Report for proper foundation design. Building Code minimum recommendations may not be adequate. The engineer can take no responsibility for the foundation without a valid Soils Report. 8. ROOFING --~S=E=E~A~R~C~H~. ___ _ ROOF SLOPE: --~S~E~E~A~R~C~H~-~-- 9. PIPE COLUMNS: Shall conform to A.S.T.M. A-53, Grade 8. TUBE STEEL: Shall conform to A.S.T.M. A-500. 10. Glu-Laminated members should be fabricated in accordance with Building Department Standards and current A.1.T.C. 117 A certificate of inspection to be submitted to Building Department prior to erection. Glu-Lams to be comnination 24F-VB. 11. Contractor and sub-contractor shall verify all conditions shown on the plans al the site prior to commencing work. 01/20/2022 Page 2 of 16 PROJECT: ADDITION/REMODEL FILE: 21-1140 VLACHOS ENGINEERING OWNER: WALSETH 530 E. Los Angeles Ave. #115355, Moocpa,k, CA 93021 ADDRESS: 2711 EL RASTRO LANE, CARLSBAD, CA. PHONE (818)-515-7233 FAX (805) 552-0347 EMAIL: manny@vlachosengineering.com ARCH: CADBUILT DATE: 10/9/21 ENGINEER: M. VLACHOS SHEET: CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK 0 STRUCTURAL CALCULATION LEGEND THE BEAMS AND SHEAR WALLS IN THESE CALCULATIONS CAN BE LOCATED ON THE STRUCTURAL FRAMING PLANS. = BEAMS 6 = SHEAR WALLS (AND STEEL FRAMES/ COLUMNS) THE FOUNDATION PADS CAN BE LOCATED ON THE FOUNDATION PLAN. □ = FOUNDATION PADS 2 01/20/2022 Page 3 of 16 PROJECT: ADDITION/REMODEL FILE: 21-1140 VLACHOS ENGINEERING OWNER: WALSETH 530 E. Los AogelesAve. #115355, Moocparl<, CA 93021 ADDRESS: 2711 EL RASTRO LANE, CARLSBAD, CA. PHONE (818) 515-7233 FAX (805) 552-0347 EMAIL: manny@vlachosengineering.com ARCH: CADBUILT DATE: ENGINEER: M. VLACHOS SHEET: CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK STRUCTURAL SUMMARY BEAMS 0 SEE THE FOLLOWING SHEETS FOR INDIVIDUAL BEAM CALCULATIONS FOUNDATION PADS A 2'-6" SQUARE x 12" THICK 3 # 4 BARS EACH WAY B 3'-6" SQUARE x 15" THICK 4 # 4 BARS EACH WAY C 4'-6" SQUARE x 18" THICK 5 # 5 BARS EACH WAY D 5'-6" SQUARE x 21" THICK 6 # 5 BARS EACH WAY LATERAL ROOF SHEATHING 5/8" CDX PLYWOOD PSR 40/20 NAILING: BOUNDARY 8d@6" o.c 8d@6" o.c 8d@ 12" o.c FLOOR SHEATHING 3/4" T&G STU NAILING EDGE FIELD: ------~--- PLYWOOD PSR-48/24 10d@ 6" o.c 10d@ 6" o.c 10d@ 12" o.c 10/9/21 3 01/20/2022 Page 4 of 16 PROJECT: ADDITION/REMODEL FILE: 21-1140 VLACHOS ENGINEERING OWNER: WALSETH 530 E Los Angeles Ave. #115355, Mompack, CA 93021 ADDRESS: 2711 EL RASTRO LANE, CARLSBAD, CA. PHONE (818) 515-7233 FAX (805) 552-0347 EMAIL: manny@vlachosengineering.com ARCH: CADBUILT DATE: 10/9/21 ENGINEER: M. VLACHOS SHEET: 4 CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK SHEAR WALL SCHEDULE (DOUBLE LETTER INDICATES TWO SIDED APPLICATION) WALLS W.S.P.3 EDGE ANCHOR SILL ATTACHMENT ALLOW. MARK NAILING4 BOLTS5 @ UPPER FLOORS SHEAR A 3/8" 8d@ 5/8"<!>@ 16d @6" o.c.2 255 6" o.c. 16" o.c. B 15/32" 10d@ 5/8"<!> @ 16d @4" o.c.2 310 6" o.c. 16" o.c. c' 15/32" 10d@ 5/8"<!> @ SDS 1/4 X 6@ 6" o.c.2 383 4" o.c. 16" o.c. o' 15/32" 10d@ 5/8"<!>@ SOS 1/4 X 6@ 6" o.c.2 499 3" o.c. 16" o.c. D01 15/32" 10d@ 3/4"<!>@ SOS 1/4 X 6@ 3" o.c.2 998 3" o.c. 12" o.c. E' 15/32" 10d@ 5/8"<!> @ SDS 1/4 X 6@ 4" o.c.2 653 2" O.C. 16" O.C. EE1 15/32" 10d@ 3/4"<!> @ SOS 1/4 X 6@ 3" o.c.2 1305 2" o.c. 12" o.c. 1. 3x boundary and edge studs required. Double 2x studs acceptable at top plates and holdowns. For wall C through EE, 3x pressure treated sill plates required against concrete. For walls CC, DD, E, and EE 3x sill plate also required at upper floors. 2. Simpson SOS 1/4 x 6 screws staggered into 4x minimum. LARR #25711 3. Wood Structural Panel applied over studs spaced at 16" o.c. Use 5-ply STRUCT I plywood, PS1- 95 or STRUCT I OSB, PS2-92. 4. Nailing at intermediate members to be spaced at 12" o.c. Only common nails shall be used (1 Od-0.148" dia., Sd-0.131" dia.) Nail gunns using "clipped head" or "sinker" nails are not acceptable. Stagger nailing in top plates, boundary members, and edge members. Edge distance for nailing at 3x boundary and panel edges shall be 1/2" minimum. 5. Use 12" long anchor bolts extending 4-1 /2" out of concrete. Also see anchor bolt notes. 6. Based on SDPWS Table 4.3A SEE NEXT SHEET FOR HOLDDOWN AND ANCHOR BOLT NOTES 01/20/2022 Page 5 of 16 PROJECT: ADDITION/REMODEL FILE: 21-1140 VLACHOS ENGINEERING OWNER: WALSETH 530 E. Los Angeles Ave. #115355, Moorpark, CA 93021 ADDRESS: 2711 EL RASTRO LANE, CARLSBAD, CA. PHONE (818) 515-7233 FAX (805) 552-0347 EMAIL: manny@vlachosenglneerlng.com ARCHITECT: CADBUILT DATE: 10/9/21 ENGINEER: M. VLACHOS SHEET: CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK HOLDOWN NOTES 1. All bolt holes shall be 1/16" (maximum) over-sized at the connection of holdowns to posts (Note on plans "Inspectors to Verify") 2. Holdown connection bolts I nuts shall be torqued 1 /2 turn beyond finger tight or as required by Manufacturer. Inspector shall verify by random inspection prior to covering walls. 3. Approved plate washers in lieu of cut washers to be used for plywood shear wall sill plate anchor bolts and for holdown connector bolts at shear walls. MINIMUM SIZE FOR SQUARE PLATE WASHERS BOLT SIZE PLATE SIZE 5/8" 0.229" X 3" X 3" 3/4" 0.229" X 3" X 3" 7/8" 5/16" X 3" X 3" ANCHOR BOLT NOTES 1. All exterior footings to have 5/8" diameter x 12" A. B. @ 48" o.c. unless otherwise noted. 2. There shall be a mimimum of 2 bolts per sill plate piece with with one bolt located within 12" of each and 3" minimum from any holdown bolt. 3. Anchor bolts holes drilled in wood shall be 1/32" minimum to 1/16" maximum oversized. 4. All anchor bolts to use approved plate washers in lieu of cut washers per table under holdown notes. 5. Anchor bolts shall have the following minimum edge distance. ANCHOR BOLTS MINIMUM EDGE DISTANCE BOLT DIAMETER EDGE DISTANCE 5/8" 1-7/8" 3/4" 2-1/4"* • 2 x 6 stud waif required 5 01/20/2022 Page 6 of 16 PROJECT: ADDITION/REMODEL FILE: 21-1140 VLACHOS ENGINEERING OWNER: WALSETH 530 E. Los Angeles Ave. #115355, Moorpark, CA 93021A.DORESS: 2711 EL RASTRO LANE, CARLSBAD, CA. PHONE (818) 515-7233 FAX (805) 552-0347 EMAIL: manny@vlachosengineering.com ARCH: CADBUILT DATE: 10/9/21 ENGINEER: M. VLACHOS SHEET: CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK BEAM LOADING CASE I SIMPLE BEAM-UNIFORM DISTRIBUTED LOAD S= A= I= BEAM LOADING CASE 11 wxlx1.5 2 X Fv 5xwxl4 384xExti. 240 SIMPLE BEAM-CONCENTRATED LOAD AT ANY POINT S= Pxaxb R, IX Fb Pxax1.5 A= v, IX Fv v, I= Pxa2 xb2 3xExflxl "' = 240 BEAM LOADING CASE Ill BEAM LOADING CASE IV CANTILEVER BEAM-UNIFORM DISTRIBUTED LOAD S= A= wxlx1.5 F, I= wx 14 BxEx.6. /',= 240 BEAM LOADING CASE V CANTILEVER BEAM-POINT LOAD AT FREE END S= p XI R F, A= PX 1.5 F, I= p X 13 3xEx.6. 240 BEAM LOADING CASE VI 6 SIMPLE BEAM-LOAD INCREASING UNIFORMLY CANTILEVER BEAM-LOAD INCREASING UNIFORMLY S= 0.1283xwx12 " 2 X Fb X A= wxl F, I= 0.01304xwxl4 2xEx8 M- BEAM LOADING CASE VII= BEAM LOADING CASE I+ BEAM LOADING CASE II S= A= I= wxl 2 X Fv wx 14 30xEx/1 01/20/2022 PROJECT: VLACHOS ENGINEERING OWNER: 530 E. Los Angeles Ave. #115355, Moorpark, CA 93021 PHONE (818) 515-7233 FAX (805) 552-0347 EMAIL: manny@vlachosengineering.com ADDRESS: ARCHITECT: ENGINEER: Page 7 of 16 ADDITION/REMODEi FILE: 21-1140 WALSETH 2711 EL RASTRO LANE, CARLSBAD, CA CADBUILT M. VLACHOS DATE: 1/20/2022 SHEET: 7 OF 16 CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK Beam No.1 Beam Loading Case: 1 Span= Dist. Loads: Roof: 36 psf * 12 !rib. Ft./1.25 = 346 pit Wall: 13 psf * 0 !rib. Ft. = 0 pit Floor: 0 psf • 0 !rib. Fl. = 0 pit Beam weight: 20 pit = 20 □If w = 366 pit Point Loads: P1 = 0 lbs. P2 = 0 lbs. P3 = 0 lbs. P4 = 0 lbs. PS= 0 lbs. Misc. pt. Load 1 = 0 lbs. Misc. pt. Load 2 = 0 lbs. Misc. et. Load 3 = 0 lbs. Total = 0 lbs. Location of point loads (b) = 0 ft. D.F. #1 24F-V8 GLB Required: Section Modulus (in3) = 20 8 Area (in2) = 17 10 Moment of Inertia (in4)= 22 20 Reactions: (lbs) R1= 1097 R2= USE: Provided: 4x12 #1 D.F. Section Modulus (in3) = Area (in2) = Moment of Inertia (in4) = Material Properties: Fb (psi)= Fv (psi)= E (psi)= 74 39 415 1000 95 1600000 2400 165 1800000 6 ft. Parallam 7 6 18 1097 2800 290 2000000 Steel 1 0 1 21600 14400 29000000 01/20/2022 PROJECT: VLACHOS ENGINEERING OWNER: 530 E. Los Angeles Ave. #115355, Moorpark, CA 93021 ADDRESS: PHONE (818) 515-7233 FAX (805) 552-0347 EMAIL: manny@vlachosengineering.com ARCHITECT: ENGINEER: Page 8 of 16 ADDITION/REMODEi FILE: 21-1140 WALSETH 2711 EL RASTRO LANE, CARLSBAD, CA. CADBUILT M. VLACHOS DATE: 1/20/2022 SHEET: 8 OF 16 CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK Beam No. 2 Dist. Loads: Roof: Wall: Floor: Beam weight: Point Loads: Beam Loading Case: 3 36 psf * 13 psf * 0 psf * 20 plf 0 !rib. Ft/1 .25 = 0 !rib. Ft. = 0 !rib. Ft. = w = = P1 = P2 = P3 = P4 = P5 = Misc. pt. Load 1 = Misc. pt. Load 2 = Misc. pt Load 3 = Total = Location of point loads (b) = Span= 173 plf 0 pit 0 plf 20 olf 193 plf 0 lbs. 0 lbs. 0 lbs. 0 lbs. 0 lbs. 0 lbs. 0 lbs. 0 lbs. 0 lbs. 0 ft. D.F.#1 24F-V8 GLB Required: USE: Provided: Section Modulus (in3) = Area (in2) = Moment of Inertia (in4)= 4x12 #1 D.F. Section Modulus (in3) = Area (in2) = Moment of Inertia (in4) = Material Properties: Fb (psi)= Fv (psi)= E (psi)= 21 12 47 Reactions: (lbs) 74 39 415 1000 95 1600000 R1= 9 7 42 386 2400 165 1800000 R2= 12 ft. Parallam 8 4 38 771 2800 290 2000000 Steel 1 0 3 21600 14400 29000000 01/20/2022 Asa· Address: 2711 El Rastro Ln Carlsbad, California 92009 Wind Results: Wind Speed: 10-year MRI 25-year MRI 50-year MRI 100-year MRI Data Source: Date Accessed: Page 9 of 16 ASCE 7 Hazards Report Standard: ASCE/SEI 7-16 Elevation: 168.65 ft (NAVO 88) Risk Category: 11 Latitude: 33 068386 Soil Class: c -Very Dense Longitude: -117.251977 Soil and Soft Rock 96 Vmph 67 Vmph 72 Vmph 77 Vmph 82 Vmph ',r:.1.,1 :11 ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1-CC.2-4, and Section 26.5.2 Mon Oct 18 2021 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability= 0.00143, MRI= 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. https: //a see 7hazardtoo I. on Ii ne/ Page 1 of 3 Mon Oct 18 2021 01/20/2022 Asa· Seismic Site Soil Class: Results: Ss S1 F, F, SMs SM1 Sos Seismic Design Category C -Very Dense Soil and Soft Rock 1.011 So, 0.366 T, 1.2 PGA: 1.5 PGA M: 1.214 F PGA 0.549 I, 0.809 C, D 0.366 8 0.444 0.532 1.2 1.102 Page 10 of 16 MCER Response Spectrum 1G Design Response Spectrum '! .... • • • • : ; f ·, .l ! J ;-I ! l S3 (g) vs T(s) ' s.(g) VS T(s) MCER Vertical Response Spectrum Design Vertical Response Spectrum ... ... • ·-•• ... •• 'l • ·-.. .. .... ...................... . ... ..........__····--· ,_JC ·J ~-' Sa(9) vs T(s) Data Accessed: Date Source: https ://a see 7 hazardtoo I. onl in e/ Sa(9) vs T(s) Mon Oct 18 2021 USGS Seismic Design Maps based on ASCE/SEI 7-16 and ASCE/SEI 7-16 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-16 Ch. 21 are available from USGS. Page 2 of 3 Mon Oct 18 2021 01/20/2022 Page 11 of 16 ASCE- The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers, or has been extrapolated from maps incorporated in the ASCE 7 standard. 1/Vhile ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Too1 or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. https: // asce 7h aza rdtool . onl ine/ Page 3 of 3 Mon Oct 18 2021 01/20/2022 Page12ol16 PROJECT: ADDITION/REMOD FILE: 21-1140 VLACHOS ENGINEERING OWNER: WALSETH 530 E. Los Angeles Ave. #115355, Moorpark, CA 93021ADDRESS: 2711 EL RASTRO LANE, CARLSBAD, CA PHONE (818) 515-7233 FAX (805) 552-0347 EMAIL: manny@vlachosengineering.com ARCH: ENGINEER: CADBUILT M. VLACHOS DATE: SHEET: CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK FOUNDATION PADS S.B.V. = ALLOWABLE SOIL BEARING VALUE (PER SOILS REPORT OR 1000 psi MIN. LOAD= SERVICE LOAD FORM BEAMS OR MISCELLANEOUS POINT LOADS. LOAD S.B.V. 1000 psi 1500 psi ~ 2000 psi :5 5000 POUNDS A A A :5 10000 POUNDS B B B :5 15000 POUNDS C B B :5 20000 POUNDS D C B :5 25000 POUNDS D D C FOR LOADS GREATER THAN 25000 POUNDS, SEE ADDITIONAL CALCULATIONS NOTE: REQUIRED PAD SIZE= SQRT (LOAD/ S.B.V.) PAD CALLOUT SIZE REINFORCEMENT A 2'-0" SQUARE x 12" THICK 3 # 4 BARS EACH WAY B 3'-6" SQUARE x 15" THICK 4 # 4 BARS EACH WAY C 4'-6" SQUARE x 18" THICK 5 # 5 BARS EACH WAY D 5'-6" SQUARE x 21" THICK 6 # 5 BARS EACH WAY P1 5'-6" SQUARE x 5'-0" DEEP #5rm12" O.C. T&B E.W. S1 6'-6" X 5'-6" x 30" THICK #5rm12" O.C. T&B E.W. LATERAL LOADNERTICAL LOAD COMBINATION(IF APPLICABLE) V 5200 LBS p 1923 LBS L 5.5 FT w 5.5 FT T 2 FT h 8 FT Mot 41600 FT-LBS Mr 24956.25 FT-LBS Mnet -16643.8 FT-LBS e -8.66 <L/6 SP -1587 PSF <L/6 SP 664 PSF <L/6 SP 20 PSF >L/6 1 /20/22 12 01/20/2022 Page13of16 PROJECT: ADDITION/REM FILE: 21-1140 VLACHOS ENGINEERING 530 E. Los Angeles Ave. #115355, Moorpark, CA 93021 PHONE (805) 340-4705 FAX (805) 552-0347 EMAIL: manny@vlachosengineering.com OWNER: WALSETH ADDRESS: 2711 EL RASTRO LANE, CARLSBAD ARCH: CADBUILT DATE: 1/20/22 ENGINEER: M. VLACHOS SHEET: 13 CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK WIND DESIGN(SIMPLIFIED DESIGN WIND PRESSURES FOR MWFRS) ASCE 7-10 28.6-1 WIND SPEED ZONE: 110 MPH IMPORTANCE (I): 1.00 (CATEGORY II) EXPOSURE: CATEGORYC I ROOF ANGLE 20° Ps = AKztPs30 Kz1= (1+K1K2K3)2 (28.6-1) K1= K2= K3= 0.51 0.38 0.17 (From Figure 26.8-1) (From Figure 26.8-1) (From Figure 26.8-1) A= 1.35 (Adjustment Factor from 28.6-1) ENCLOSURE: DIMENSIONS: K,.= 1.00 (From Figure 26.8-1) or 1.00 from ASCE 7-10 26.8.2 p,30= 26.6 (From Figure 28.6-1 Case C) ENCLOSED 50 ft WIDE 60 ft LONG 30 ft HIGH MEAN ROOF HIGHT: 3o ft I < 60' ps = 35.9 PSF ~_o_.6~p_s_= __ 2_1_.s __ P_S_F __ ~IASD 01/20/2022 Page14of16 PROJECT: ADDITION/REMODE FILE: 21-1140 VLACHOS ENGINEERING OWNER: WALSETH 530 E. Los Angeles Ave. #115355, Moorpark, CA 93021 ADDRESS: 2711 EL RASTRO LANE, CARLSBAD, CA. PHONE (805) 340-4705 FAX (805) 552-0347 EMAIL manny@vlachosengineering.com ARCHITECT: CADBUILT DATE: 1/20/22 ENGINEER: M. VLACHOS SHEET: 14 CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK EQUIVALENT LATERAL FORCE PROCEDURE OCCUPANCY CLASS: ~I --1-1 -~ IMPORTANCE FACTOR: 1.0 LATITUDE 33.0684 LONGITUDE: -117.2520 Ss: 1.011 s,: 0.366 SOIL PROFILE: D Sos: 0.809 S01 : I 0.366 SEISMIC DESIGN CATEGORY: I C R = 6.5 (PLYWOOD SHEARWALLS), R = 4.5 (IMF), R = 3.5 (OMF), R = 1.25 (CANTILVER COLUMNS) _k_ 0.124 Cs1R•65J = (R/1) = V=Cs•W=0.124 xW VAso=VxW/1.4= 0.089 xW w/ p = 1.31 VAso = V x W / 1.4 = 0.116 x WI _k_ Cs1R•• sJ = (R/1) 0.180 V=Cs•W=0.180 xW VAso=VxW/1.4= 0.128 xW w/p= 1.31 VAso=VxW/ 1.4= 0.167 xWI _k_ 0.231 Cs(R=3.5J = = (R/1) V=Cs•W=0.231 xW VAso=VxW/1.4= 0.165 xW w/p=1.3IVAso=VxW/1.4= 0.215 xWI -_k_ = 0.647 S(R=1.25) -(R/1) V=Cs•W=0.647 xW VAso=VxW/1.4= 0.462 xW w/ p = 1.31 VAso = V x W / 1.4 = 0.601 x WI 01/20/2022 Page 15 of 16 PROJECT: ADDITION/REMODEL FILE: 21-1140 VLACHOS ENGINEERING OWNER: WALSETH 530 E. Los Angeles Ave. #115355, Mompark, CA 93021 ADDRESS: 2711 EL RASTRO LANE, CARLSBAD, CA. PHONE (805) 340-4705 FAX (805) 552-0347 EMAIL: manny@vlachosengineering.com ARCHITECT CADBUIL T ENGINEER: M. VLACHOS DATE: 1 /20/22 SHEET: 15 CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK DISTRIBUTION OF LATERAL FORCES -~~· WIND: p =I 22 !PSF h, = 4 FT. (FROM WIND LOAD CALC. SHEET) F1 - F1 = (h2 + h1/2) x P h1 = 8 FT. F, = 8 Fl. x 22 PSF = 172 #/ft ---" ' SEISMIC: V=! o.116jxw R=6.5 (FROM SEISMIC LOAD CALC. SHEET) F' . 1· ROOF= 16 PSF WALLS= 7 PSF 23 PSF X 0.116 2.668 PSF WIND vs SEISMIC: 172.368 WIND #/FT = 65 TRANSITION POINT 2.668 SEISMIC #/FT FT. - 01/20/2022 Page 16 of 16 PROJECT: ADDITION/REMODEL FILE: 21-1140 VLACHOS ENGINEERING OWNER: WALSETH 530 E. Los Angeles Ave. #115355, Moo,pa,k, CA 93021 ADDRESS: 2711 EL RASTRO LANE, CARLSBAD, CA. PHONE (805) 340-4705 FAX (805) 552-0347 EMAIL: manny@vlachosengineering.com ARCH: CADBUILT DATE: 1/20/22 ENGINEER: M. VLACHOS SHEET: CALCULATIONS VALID ONLY WITH ENGINEER'S SEAL AFFIXED TO FIRST SHEET IN RED INK SHEAR FORCE TRIB TRIB TOTAL WALL LINE WIND SEIS. DIST WIDTH FORCE LENGTH NO (#/ft) (psn X (ft) X (ft) (#) (ft) 1 2.7 18 14 680 14.0 2 2.7 18 12 583 16.0 3 2.7 18 12 583 7.0 4 2.7 18 12 583 11.5 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 SHEAR FORCE (#/It) 49 36 83 51 SHEAR WALL TYPE B B B B HD TYPE HDU2 HDU2 HDU2 HDU2 • HD per Simpson MFR. Use 4x4 post minimum at each end of each wall requiring holdowns. 16 UPLIFT (lbs) -467 -353 -779 -483 NOTE ALL PLYWOOD SHEAR WALLS SHOULD EXTEND FROM FLOOR TO ROOF DIAPHRAGM. \.._ City of Carlsbad Ct] Leucadia Wastewater District 1960 La Costa Ave. D Vallecitos Water District 201 Vallecitos de Oro Carlsbad, CA 92009 (760) 753-0155 San Marcos, CA 92069 (760) 744-0460 The following project has been submitted for building permits: Plan Check #: Permit#: CBR2021-3604 Property Owner: JB AND CB LIVING TRUST 03-17-17 Project Address: 2711 EL RASTRO LN Assessor's Parcel#: 2551060400 Project Description: WALSETH; (509 S~L,t,DDITION TWO N_~\A/__t3_~ROOMS AND l __ BATH. _____ _ City Certification: City of Carlsbad Building Division Date: February 23, 2022 ~-~- Please indicate in the space below that the owner has entered into an agreement to have your agency provide public sewer service to the premises, and/or if the existing service is adequate for this project and all required conditions have been satisfied. Permits will not be issued until this form is completed and returned to our office. This space to be completed by District Personnel I certify the district requirements for sewer service have been satisfied. -1 Approved by: -~~------ Title: FIELD SERVICES SPECIALIST Community & Economic Development -Building Division 1635 Faraday Avenue, Carlsbad, CA 92008-7314 760-602-2700 ! 760-602-8560 f: www.carlsbadca.gov STORM WATER POLLUTION PREVENTION NOTES 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN IS EMINENT. 2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING RAINFALL. 3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT ( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE. 6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. 7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY REGULATIONS. OWNER'S CERTIFICATE: I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTIENT PRACTICABLE TO AVOID THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETIE AND APPROVED BY THE CITY OF CARLSBAD. Justin Walseth OWNER(WQ~~/<GENT NAME (PRINT) Jt,.sfil,\, /JJ,,J,stlk, OWNER(',;.).,L~;,S,,oWENT NAME (SIGNATURE E-29 2/25/2022 DATIE STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP E-29 CB E,dD~J .~ 5G,Cf/ SW_ BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials BMPs Control BMPs Management BMPs Pollution Control BMPs C: -C: C: 0 -0 0 :;::; C: C: ,::, :;::; :;::; "' 0 "' ,::, "' ,::, "' C: 0 0 C: C: "' E C: E C: 0 0 :, :, 0 '6 ·t: .Q. 0 0 E ;; L L :;::; "' :::;; ,::, "' "' :;; --C: :, >, "' C: ., L C: c "' "' "' 0 ·;:: '-er L 0 C: "' 0. "' ·;:: -C: "' C: > L ., 0 Best Management Practice* <'1J C: 013 0 (D 0. L 0 ., 0 L 0 "' w > C: :;::; :.c "' "' "' "' ., 0 C: u "' ~ "' 0 -C: E UL "' ,::, '" "' :::;; ~ " C: (BMP) Description ➔ "' 0 ., U) ·e "' "' "' "' "' (D '0 C "' C: ,::, "' C: 0 ::::, -" " :i 2!: Q) 0 -0 0 0 "'C: L 0 ~~ ,::, >, 0 "' C: C: 0 "' g E :;::; C: 0 (D U) ·-"' 0,-u "' Oo "' "' X :::;; 0 "' 0 C: ., "' E 0 -N v, i:l 0 0 Ol:.;:; " ~-~ E~ 0 ·c. L-;,: "' " 0 "' E CL '" -:, .a E al =-= CJ) =-= 3: L. :.;:; 15 ·;:: 0.. 0 "' ., L,_ C: 0 L 0 CL L -,::, £.~ 0 L "' :, ,::, ·-"' ·-,::, ., 0 0 C: "' --,::, 0 0 0 a. '6 "' "' > ~ 0 L-.Q L .a 0 -~ ~ 0 ·-0 Q) L 0 = C ·-C: L 0 -0 C: 0 0 0 "' -o -.c: "' -o 0 0 "' 0 0 L 0 " .c: .a L -0 0 -L (/) C: .8 0 0 L 0 ~o 0 -V) 0. 0 oO 0 3: WO iJi iJi U) u G: 0 c.n> U) U) 0.. U)"' ;,: 0.. 0.. 0 0.. :::;; UJ :::;; c.nu c.n :::;; CASQA Designation ➔ r-.. a:, 0, "1 .... '° <O r-.. a:, 0 N "1 r-.. a:, N "1 .... '° I I I I I I I I I I I I I I I I I I I I I I I u u u u w w w w w w w w "' "' U) U) U) U) :::;; :::;; :::;; ~ :::;; Construction Activity w w w w U) U) U) U) U) U) (/) U) e-e-z z z z ;,: 3: ;,: 3: X Grodinn !Soil Disturbance X X Trench inn /Excavation X X Stockoilino X X Drill inn /Barino Concrete/Asoholt Sowcuttino Concrete Flotwork Pavina X Conduit/Pioe Installation X X X Stucco/Mortar Work X X X Waste Disoosal X Stoninn !Lav Down Area Eouioment Maintenance and Fuelino Hazardous Substance Use/Storaoe Dewaterino Site Access Across Dirt Other (list\: Instructions: 1. Check the box to the left of all applicable construction activity (first column) expected to occur during construction. 2. Located along the top of the BMP Tobie is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column. 3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how ta apply them to the project. SHOW THE LOCATIONS OF ALL CHOSEN BMPs ABOVE ON THE PROJECTS SITE PLAN/EROSION CONTROL PLAN. SEE THE REVERSE SIDE OF THIS SHEET FOR A SAMPLE EROSION CONTROL PLAN. PROJECT INFORMATION Site Address: 2711 El Rastro Lane , 32551-060-400 Assessors Parcel Number: Emergency Contact: Name: Justin Walseth 24 Hour Phone: 858. 531. 5699 Construction Threat to Storm Water Quality (Check Box) 0 MEDIUM IX] LOW "' -"' 0 3:-C: "' ., :, E 0 ., '2 "' oo N C: oo ::c:::;; <O I :::;; 3: ., -"' o-;,:c: " ., E -"' ~ "' O 0 C: C: 0 0 u:::;; a:, I :::;; 3: X Page 1 of 1 REV 02/16