Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2285 RUTHERFOLD RD; ; FPC2021-0080; Permit
city of Carlsbad Print Date: 04/14/2022 Permit No: FPC2021-0080 Job Address: 2285 RUTHERFORD RD, CARLSBAD, CA 92008-8815 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120620800 Track #: Applied: 05/13/2021 Valuation: $5,522,318.34 Lot #: Issued: 06/15/2021 Occupancy Group: Project #: Finaled Close Out: 04/13/2022 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check#: Final Inspection: Project Title: Description: QUIDEL - FIRE ALARM RETROFIT (ADDRESSABLE, 272 DEVICES) Applicant: FPContractor: PYRO-COMM SYSTEMS INC PYRO-COMM SYSTEMS INC CHARLES KRETZING 15531 CONTAINER LN 5115 AVENIDA ENCINAS, #G HUNTINGTON BEACH, CA 92649-1530 CARLSBAD, CA 92008-4387 (714) 902-8000 (760) 930-6014 FEE AMOUNT FIRE Hourly Services (each additional hour) $149.00 FIRE Hourly Services (first hour) $159.00 FIRE Hourly Services (first hour) $175.00 FIRE New Alarm System $1,265.00 Total Fees: $1,748.00 Total Payments To Date: $1,748.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov I Pyro-Comm Systems, Inc. 5115 AVENIDA ENCINAS CARLSBAD, CA 92008 (760) 930-6014 FAx (760) 930-6015 Quidel 2285 Rutherford Road Carlsbad, California 92008 Fire Alarm System Submittal PCSI Job# 2021062 FIRE ALARM SYSTEM MFG. MODEL# DESCRIPTION CSFM# [CONTROL PANELS] NOTIFIER NFS2-640 Fire Alarm Control Panel 7165-0028:0243 NOTIFIER LEM-320 Loop Expander Module 7165-0028:0243 NOTIFIER BMP-1 Blank Module 7165-0028:0243 NOTIFIER BP2-4 Battery Dress Plates 7165-0028:0243 NOTIFIER CPU2-640 Central Processing Unit 7165-0028:0243 NOTIFIER DP-1B Blank Panel 7165-0028:0243 NOTIFIER DR-D4 Door Assembly 7165-0028:0243 NOTIFIER KDM-R2 Keyboard Display Module 7165-0028:0243 NOTIFIER FDM-1 Dual Monitor Module 7300-0028:0219 NOTIFIER FMM-1 Monitor Module 7300-0028:0219 NOTIFIER FRM-1 Relay Module 7300-0028:0219 I [AUXILIARY POWER SUPPLIES] NOTIFIER PSE-10 a 10 Amp Sync. Aux. Power Supply 7315-0028:0513 I NOTIFIER BAT-12120 Battery-12 AH N/A NOTIFIER BAT-12550 Battery-55 All N/A I NOTIFIER NFS-LBB Battery Back Box N/A I WWW.PYROCOMM.COM C-10 612153 CORPORATE OFFICE • 15531 CONTAINER LANE• HUNTINGTON BEACH, CA 92649 (714) 902-8000 NORTHERN CA REGIONAL OFFICE 10966 BIGGE STREET• SAN LEANDRO, CA 94577 (510)632-1208 D Pyro-Comm Systems, Inc. 5115 AVENIDA ENCINAS CARLSBAD, CA 92008 (760) 930-6014• FAX (760) 930-6015 [DIALER PANELS] NOTIFIER UDACT-2 Universal Alarm Communicator (see panel CSFM) [ANNUNCIATORS] NOTIFIER LCD2-80 Annunciator 7120-0028:156 [DETECTORS] NOTIFIER FST-951 Intelligent Thermal (Heat) Detector 7270-0028:0196 NOTIFIER FSP-95 1 Low-Profile Intelligent Smoke Det. 7272-0028:0206 NOTIFIER FSP-95 1R Remote Test Capable Intell. Smoke Det. 7272-0028:0206 NOTIFIER B300-6 Flanged Mounting Base 7300-1653:0109 SYST SENS. DNR Address Duct Det. Housing 3242-1653:0209 SYST SENS. DNRW Weatherproof Address Duct Det. Housing 3242-1653:0209 NOTIFIER B501 Flangeless Detector Base 7300-1653:0109 [MANUAL PULL STATIONS] NOTIFIER NBG-12LX Address Manual Pull Station 7150-0028:0199 [SIGNALING DEVICES] SYST.SENSR. SCWL Ceiling Strobe, Standard cd-White 7320-1653:0504 SYST.SENSR. P2WL 2-wire Horn/Strobe, Standard cd-White 7125-1653:0503 SYST.SENSR. PC2WL Clg. 2-wire Horn/Strobe, Standard cd-White 7125-1653:0503 SYST.SENSR. P2RK 2-wire Horn/Strobe Weatherproof-Red 7125-1653:0503 SYST.SENSR. PC2RI( Clg. 2-wire Horn/Strobe Weatherproof-Red 7125-1653:0503 SYST.SENS. SSM24-10 Sprinkler Bell 10" 7135-1653:0217 [MISC] TELGUARD TG7-FS Dual Path Communicator, Cellular &/or IF 7300-1402:0109 SYST.SENS. RA100Z Remote Indicator L.E.D. 7120-1653:0212 SYST.SENS. PR-1 24VDC Relay 7300-1653:0172 NOTIFIER PRN-7 Fire Alarm Event Printer 7305-0028:0501 SPACEAGE 55U00685 Document Storage Cabinet N/A . WWW.PYROCOMM.COM C-10 612153 CORPORATE OFFICE 15531 CONTAINER LANE• HUNTINGTON BEACH, CA 92649 (714) 902-8000 NORTHERN CA REGIONAL OFFICE • 10966 BIGGE STREET• SAN LEANDRO, CA 94577 (510) 632-1208 NOTIFIER® by Honeywell NFS2-640 Intelligent Addressable Fire Alarm Control Panel General The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products meet virtually every application requirement. The NFS2-640's modular design makes system planning easier. The panel can be configured with just a few devices for small building applications, or networked with many devices to protect a large cam- pus or a high-rise office block. Simply add additional peripheral equipment to suit the application. A host of other options are available, including single- or multichan- nel voice; firefighter's telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection products for challeng- ing environments; wireless fire protection; and many additional options. NOTE: Unless called out with a version-specific "E" at the end of the part number, "NFS2-640" refers to models NFS2-640 and NFS2-640E; simi- larly, "CPU2-640" refers to models CPU2-640 and CPU2-640E. Features Certified for seismic applications when used with the appropriate seismic mounting kit. Approved for Marine applications when used with listed compati- ble equipment. See DN-60688. One, expandable to two, isolated intelligent Signaling Line Circuit (SLC) Class A, B, or X. Wireless fire protection using SWIFT Smart Wireless Integrated Fire Technology. See DN-60820. Up to 1.59 detectors and 159 modules per SLC; 318 devices per loop/636 per FACP or network node. - Detectors can be any mix of ion, photo, thermal, or multi-sen- sor; wireless detectors are available for use with the FWSG. - Modules include addressable pull stations, normally open con- tact devices, two-wire smoke detectors, notification, or relay; wireless modules are available for use with the FWSG. Standard 80-character display, 640-character large display (NCA-2), or display-less (a node on a network). Network options: - High-speed network for up to 200 nodes (NFS2-3030, NFS2- 640, NFS-320(C), NFS-320SYS, NCD, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). - Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCD, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP- 300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC- EM is used in network paging. 6.0 A switch mode power supply with four Class A/B built-in Noti- fication Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization. Built-in Alarm, Trouble, Security, and Supervisory relays. Field-programmable on panel or on PC. VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel data- bases. Upgrade panel firmware. Autoprogramming and Walk Test reports. Multiple central station communication options: - Standard UDACT - Internet - Internet/GSM 80-character remote annunciators (up to 32). EIA-485 annunciators, including custom graphics. Printer interface (80-column and 40-column printers). History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. Alarm Verification selection per point, with automatic counter. Presignal/Positive Alarm Sequence (PAS). Silence inhibit and Auto Silence timer options. March time/temporal/California two-stage coding/strobe synchro- nization. Full QWERTY keypad. Battery charger supports 18-200 AH batteries. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill using monitor modules. Automatic time control functions, with holiday exceptions. Surface Mount Technology (SMT) electronics. Extensive, built-in transient protection. Powerful Boolean logic equations. Support for SCS Series smoke control system in HVAC mode. NCA-2 AS PRIMARY DIsPLAY Backlit, 640-character display. Supports SCS Series smoke control system in FSCS mode when SCS is connected to the NCA-2 used as primary display. Supports DVC digital audio loop. Printer and CAT EIA-232 ports. EIA-485 annunciator and terminal mode ports. Alarm, Trouble, Supervisory, and Security relays. DN-7111:N • 12/20/2020 - Page 1 of 9 I 1 I I SWIFT WIRELESS Self-healing mesh wireless protocol. Each SWIFT Gateway supports up to 50 devices: 1 wireless gate- way and up to 49 SWIFT devices. Up to 4 wireless gateways can be installed with overlapping net- work coverage. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). Low-pressure CO2 listed. DIGITAL VOICE AND TELEPHONE FEATURES Up to eight channels of digital audio. 35, 50, 75, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series; NCA-2 required as primary display). Solid-state digital message generation. Firefighter telephone option. 30- to 120-watt high-efficiency amplifiers (AA Series). Backup tone generator and amplifier option. NFS2-640 can also integrate with the FirstCommand® Emer- gency Communications System. See DN-60772. HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 A POWER SUPPLY (6.0 A IN ALARM) 120 VAC (NFS2-640); 240 VAC (NFS2-640E). Displays battery current/voltage on panel (with display). FLASHSCAIP INTELLIGENT FEATURES Polls up to 318 devices in less than two seconds. Activates up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - up to nine levels. Pre-alarm ONYX intelligent sensing - up to nine levels. Day/Night automatic sensitivity adjustment. Sensitivity windows: - Photo - 0.5 to 2.35%/foot obscuration. - High-Sensitivity Photoelectric (VIEW®) - Open Air Protection (0.5% - 2.0%/ft. obscuration), Special Applications (0.02%- 0.5%/ft. obscuration) - Multi-Criteria Detector - Open Air Protection (2.52-3.89%/ft. obscuration), Special Applications (1.13-2.52%/ft. obscuration) Drift compensation (U.S. Patent 5,764,142). Degraded mode: In the unlikely event that the CPU2-640 micro- processor fails, FlashScan detectors revert to degraded operation and can activate the CPU2-640 NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. Multi-detector algorithm involves nearby detectors in alarm deci- sion (U.S. Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. Up to 32 remote displays SLC Intelligent Loop I °'j FPTI-951 NBG-I2LX t XP6/10 FSP-951 FMM-1 FCM-1 FST-951 I FCO-951 DC NAC etc. FRM-1 Relay Contact SLC Intelligent Loop 2 FWSG I EIA-485 2048 annunciator/control IM ACM-8R ACM/AEM-24AT LDM-32 Relay Control LED Annunciator Custom Graphics IA-232 Optional 636-point UDACT PRN Series Printer EIA-485 OR NCA-2 OR with no display Sample System Options N FS2-640 "C" cabinet size shown Dual phone lines to Central Station 7111blok-2014.wmf I I I I Page 2 of 9— DN-7111:N • 12/20/2020 * I FSV-951 SERIES VIE viP (VERY INTELLIGENT EARLY WARNING) HIGH-SENSITIVITY SMOKE DETECTOR Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals. Addressable operation pinpoints the fire location. Ivory models (-IV) support CLIP mode as well as FlashScan. ULC listed models available; "A" models are ULC Listed. -R is retrofit, backwards compatible for use with older panels FCO-951/-IV ADVANCED MULTI-CRITERIA FIREICO DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). 135°F (57.2°C) fixed-temperature heat detector. Transmits an alarm signal due to heat. Separate signal for life-safety CO detection. Optional addressable sounder base for Temp-3 (fire) or Temp-4 (CO) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm ithmunity. ULC listed models available; -A models are ULC Listed. FPTI-951(A) INTELLIGENT MULTI-CRITERIA DETECTOR Combined Photoelectric Thermal and Infrared Sensor UL 268 7th Edition and UL 521 Listed; Canadian models CAN/ ULC S529 and CAN/ULC S530 Microprocessor-based technology; combination photo, thermal, and infrared technology. FPC-951(A) PHOTOELECTRIC/CO SENSOR Combined photoelectric and carbon monoxide sensor FSCO-95(A) INTELLIGENT CO SENSOR Carbon monoxide sensor FS-OSI-RI(A) ADDRESSABLE INTELLIGENT SINGLE-ENDED BEAM SMOKE DETECTOR Intelligent addressable reflector-type linear optical beam smoke detector Fast, easy, and intuitive beam alignment indicated by directional LED arrows Long range coverage of 16-328 ft (5-100 m) is standard; no sepa- rate long-range kit required FMM-4-20 GAS DETECTION MODULE Interface to industry-standard linear scale 4-20 mA sensors. Five programmable thresholds. FM Approved, Class 6320 (Stationary Gas Sensors/Detectors) INTELLIGENT VESDA DETECTORS Intelligent aspiration smoke detectors connect directly to the SLC loop of compatible ONYX® Series panels: - VEA-040-AOO-NTF, VEA-040-AlO-NTF - VEP-AOO-P-NTF, VEP-AlO-P-NTF, VEP-A00-1 P-NTF - VEU-AOO-NTF, VEU-A10-NTF Models offer LED display, LCD display, or both Coverage options for spaces up to 69,965 square feet FlashScan, Exclusive World-Leading Detector Protocol At the heart of the NFS2-640 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). FlashScan is an all- digital protocol that gives superior precision and high noise immunity. In addition to providing quick identification of an active input device, this protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS2-640 to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS2-640 with industry-leading smoke detection capability. These complex algorithms require many calculations on each reading of each detector, and are made possible by the high-speed microcom- puter used by the NFS2-640. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces mainte- nance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference. Maintenance Warnings: When the drift compensation performed for a detector reaches a certain level, the performance of the detec- tor may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automat- ically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predetermined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to acti- vate special control functions. Self-Optimizing Pre-Alarm: Each detector may be set for "Self- Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing: A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to consider read- ings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature. The FACP "learns" what devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installation, even if only a portion of the detectors are installed. Keypad Program Edit (with KDM-R2) The NFS2-640, like all NOTI- FIER intelligent panels, has the exclusive feature of program cre- ation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS2- 640 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the pro- gram to be entered with independent per-point segments, while the NFS2-640 simultaneously monitors other (already installed) points for alarm conditions. VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confi- dence in the site-specific software. It is Windows®based and pro- vides technologically advanced capabilities to aid the installer. The installer may create the entire program for the NFS2-640 in the com- fort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. DN-71 11:N • 12120/2020 - Page 3 of 9 Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS2-640's flexible system design. Rows: The first row of equipment in the cabinet mounts in the chas- sis shipped with the FACP. Mount the second, third, or fourth rows of equipment in a CHS-4 series chassis or, for Digital Voice Command products, in CA-1 or CA-2. (For DVC-EM and DAA2/DAX compo- nents see DVC Manual, for DS series components see DS-AMP Manual, for DVC-AO applications, see AA Series Installation Man- ual). Other options are available; see your panel's installation man- ual. Wiring: When designing the cabinet layout, consider separation of power-limited and non-power-limited wiring as discussed in the NFS2-640 Installation Manual. Positions: A chassis offers four basic side-by-side positions for components; the number of modules that can be mounted in each position depends on the chassis model and the size of the individual module. There are a variety of standoffs and hardware items avail- able for different combinations and configurations of components. It is critical that all mounting holes of the NFS2-640 are secured with a screw or standoff to ensure continuity of Earth Ground. Layers: The control panel's chassis accepts four layers of equip- ment, including the control panel. The CPU2-640 fills three positions (left to right) in the first-installed layer (the back of the chassis); its integral power supply occupies the center two positions in the next two layers; the optional display occupies (the left) two positions at the front, flush with the door. Some equipment, such as the NCA-2, may be mounted in the dress panel directly in front of the control panel. The NCA-2 can be used as a primary display for the NFS2- 640 (use NCA/640-2-KIT) by directly connecting their network ports (required in Canadian stand-alone applications); see NCA-2 data sheet for mounting options (DN-7047). Expansion: Installing an LEM-320 Loop Expander Module adds a second SLC loop to the control panel. The LEM-320 is mounted onto the CPU2-640, occupying the middle-right, second (back) slot on the chassis. Networking: If networking two or more control panels, each unit requires a Network Communication Module or High-Speed Network Communication Module. (HS-NCM can support two nodes; see "Networking Options" on page 4). These modules can be installed in any option board position (see manual), and additional option boards can be mounted in front of the network communication modules. KDM.R2 Controls and Indicators Program Keypad: QWERTY type (keyboard layout, see figure). 12 LED Indicators: Power; Fire Alarm; Pre-Alarm; Security; Super- visory; System Trouble; Signals Silenced; Points Disabled; Control Active; Abort; Pre-Discharge; Discharge. Keypad Switch Controls: Acknowledge/Scroll Display; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED backlight. Product Line Information "Configuration Guidelines" on page 4 "Main System Components" on page 4 "Networking Options" on page 4 "Auxiliary Power Supplies and Batteries" on page 5 "Audio Options" on page 5 "Compatible Devices, EIA-232 Ports" on page 5 "Compatible Devices, EIA-485 Ports" on page 5 "Compatible Intelligent Devices" on page 6 "Enclosures, Chassis, and Dress Plates" on page 7 "Other Options" on page 8 CONFIGURATION GUIDELINES Stand-alone and network systems require a main display. On sys- tems with one FACP (one CPU2-640/-640E), display options are the KDM-R2 or the NCA-2. On network systems (two or more networked fire panel nodes), at least one NCD, NCA-2, NCS, or ONYX Works annunciation device is required. Other options listed as follows. MAIN SYSTEM COMPONENTS CPU2-640: Central processing unit (CPU) with integral 3.0 A (6.0 A in alarm) power supply for an NFS2-640 system. Includes control panel factory-mounted on a chassis; one Signaling Line Circuit expandable to two; documentation kit. Order one per system or as necessary (up to 103 network nodes) on a network system. (Non- English versions also available: CPU2 -640-FR, CPU2-640-PO, CPU2-640-SP.) CPU2-640E: Same as CPU2-640 but requires 240 VAC, 1.5 A, (3.0 A in alarm). (Non-English versions also available: CPU2-640E-P0, CPU2-640E-SP.) KDM-R2: 80-character backlit LCD display with QWERTY program- ming and control keypad. Order two BMP-i blank modules and DP- DISP2 mounting plate separately. Requires top row of a cabinet. Required for each stand-alone 80-character display system. The KDM-R2 may mount in network nodes to display "local" node infor- mation as long as at least one NCA-2 or NCS/ONYX Works network display is on the system to display network information. (Non-English versions also available: KDM-R2C for ULC application, KDM-132-1713, KDM-R2-PO, KDM-132-SP.) NCA-2: Network Control Annunciator, 640 characters. On single CPU2-640/-640E systems, the optional NCA-2 can be used as the Primary Display for the panel and connects directly to the CPU2- 640/-640E. On network systems (two or more networked fire panel nodes), one network display (either NCA-2 or NCS/ONYX Works) is required for every system. On network systems, the NCA-2 connects to (and requires) a standard Network Communication Module or High-Speed Network Communication Module. Mounts in a row of FACP node or in two annunciator positions. Mounting options include the DP-DlSP2, ADP-413, or in an annunciator box, such as the ABS-2D. In CAB-4 top-row applications, a DP-DISP2 and two BMP-i blank modules are required for mounting. Required for NFS2-640 applications employing the DVC-EM with DAL devices. Non-English versions are available. NGA-2 are available for ULC applications. For marine applications, order NCA-2-M; for non- English Marine applications, order NCA-2-M and the appropriate KP-KIT-XX. See DN-7047. NCD: As part of a standalone NFS2-640 system, the NCD can serve as Primary Display for the panel, to provide control and status capa- bilities on displayless nodes. On network systems, the NCD con- nects to (and requires) a standard Network Communication Module or High-Speed Network Communication Module. Mounting options include the ABS-TD for standalone applications. In the CAB-4 series the NCD can be mounted in the top row with a DP-GDISi or lower rows using a DP-GDIS2. See DN-60974. NCA/640-2-KIT: Bracket installation kit required to mount NCA-2 to the CPU2-640/-640E's standard chassis. DP-D1SP2: Dress panel for top row in cabinet with CPU2-640/640E installed. ADP2-640: Dress panel for middle rows with CPU2-640/640E. BMP-1: Blank module for unused module positions. BP2-4: Battery plate, required. (Existing JADT-XLS-BP2-4 may be used in retrofits.) LEM-320: Loop Expander Module. Expands each NFS2-640 to two Signaling Line Circuits. See DN-6881. NETWORKING OPTIONS NCM-W, NCM-F: Standard Network Communications Modules. Wire and multi-mode fiber versions available. See DN-6861. Page .4 of 9— DN-71 11:N • 12/20/2020 HS-NCM-W(-2), HS-NCM-11111F, HS-NCM-SF, HS-NCM-1NMF(-2), HS-NCM-1NSF(-2), HS-NCM-MFSF: High-speed Network Commu- nications Modules that can connect to two nodes. Wire, single-mode fiber, multi-mode fiber, and media conversion models are available. See DN-60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), multi-mode fiber connection (RPT-F), or allow- ing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN-6971. ONYXWorks: UL-listed graphics PC workstation, software, and computer hardware. See DN-7048 for specific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. (Replaces NFN-GW- EM.) See DN-60499. NWS-3: NOTI.FIRE.NETTM Web Server. See DN-6928. CAP-GW: Common Alerting Protocol Gateway. See DN-60756. VESDA-HLI-GIN: VESDAnet high-level interface gateway. See DN- 60753. LEDSIGN-GIN: UL-listed sign gateway. Interfaces with classic and high-speed NOTI.FIRE.NET networks through the NFN Gateway. See DN-60679. OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See ON- 60679. AUXILIARY POWER SUPPLIES AND BATTERIES ACPS-610: 6.0 A or 10.0 A addressable charging power supply. See DN-60244. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See DN-5952. FCPS-24S6/S8: Remote 6 A' and 8 A power supplies with battery charger. See DN-6927. BAT Series: Batteries. NFS2-640 uses two 12 volt, 18 to 200 AH batteries. See ON-6933. AUDIO OPTIONS NOTE: For mounting hardware, see "Enclosures, Chassis, and Dress Plates" on page 7 and peripheral data sheets. DVC-EM: Digital Voice Command, digital audio processor with mes- sage storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. Capable of playing up to eight simultane- ous messages when used with Digital Audio Loop (DAL) devices. See DN-7045. DVC-RPU: Digital Voice Command Remote Paging Unit for use with DVC-EM. Includes the keypad/display. See DN-60726. DS-DB: Digital Series Distribution Board, provides bulk amplification capabilities to the DVC-EM while retaining digital audio distribution capabilities. Can be configured with up to four DS-AMPs, supplying high-level risers spread throughout an installation. See DN-60565. DVC-KD: DVC-EM keypad for local annunciation and controls; sta- tus LEDs and 24 user-programmable buttons. See DN-7045. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Amplifier, part of the DS-DB system. See DN-60863. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC-EM, DS-DB distribution board, and DAX and DAA2 Series amplifiers. See DN-60633. DVC-AO: DVC Analog Output board provides four analog output cir- cuits for use with AA Series amplifiers. Four-channel operation sup- ported. See ON-7045. DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with Power supply; includes chassis. See DN-60556. DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly' with power supply; includes chassis. See DN-60556. DAA2-7525(E): 75W, 25 Vrms digital audio amplifier assembly with power supply; includes chassis. See DN-60556. DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. TELH-1: Firefighter's Telephone Handset for use with the DVC-EM when mounted in the CA-2 chassis. See DN-7045. CMIC-1: Optional microphone and microphone well assembly used with the CA-1 chassis. RM-1/RM-1SA: Remote microphone assemblies, mount on ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA) stand-alone cabi- nets. See DN-6 728. AA-30: Audio Amplifier, 30 watts, 25 Vrms. Includes amplifier and audio input supervision, backup input, and automatic switchover, power supply, cables. See DN-3224. AA-120/AA-100: Audio Amplifier provides up to 120 watts of 25 VRMS audio power for the NFS-640. The amplifier contains an inte- gral chassis for mounting to a CAB-B4, -C4, or -D4 backbox (con- sumes one row). Switch-mode power. Includes audio input and amplified output supervision, backup input, and automatic switcho- ver to backup tone. Order the AA-100 for 70.7 VRMS systems and 100 watts of power. See DN-3224. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifi- ers are compatible with DVC-EM systems running 5R4.0. For spe- cific information on DAA-50 series amplifiers, refer to DN-7046. For information on DAA-7525 Series, refer to DN-60257. NFC-25/50: 25 watt, 25 VRMS, emergency Voice Evacuation Con- trol Panel (VECP) with integral commercial microphone, digital mes- sage generator, and single-/dual-channel Class A or Class B speaker circuits. See DN-60772. COMPATIBLE DEVICES, &A-232 PORTS PRN-7: 80-column printer. See DN-60897. V54095/5: Printer, 40-column, 24V. Mounted in external backbox. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACP5 and/or peripherals. See DN-6870. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24AT: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yellow; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM- 48A to 96 points. See DN-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See ON- 3558. FDU-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN- 6820. I I I 1 DN-7111:N • 12/20/2020- Page 5 of 9 LCD2-80: Terminal and ACS mode. 80-character, backlit LCD dis- FST-951H: White, low-profile intelligent 190°F fixed thermal sensor, play. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FlashScan only. Must be mounted to one of the bases listed below. FACP. See DN-60548. ULC: FST-951 HA. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32; remote custom graphic driver modules. See DN-0551. SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers SCS- 8L, SCE-8L; eight (expandable to 16) circuits (HVAC only). See DN- 48 18. TM-4: Transmitter Module. Includes three reverse-polarity circuits and one municipal box circuit. Mounts in panel module position (sin- gle-address-style) or in CHS2-M2 position. See DN-6860. UDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. UZC-256: Programmable Universal Zone Coder provides positive non-interfering successive zone coding. Microprocessor-controlled, field-programmable from lBM®compatible PCs (requires optional programming kit). Up to 256 programmable codes. Mounts in BB- UZC or other compatible chassis (purchased separately). See ON- 3404. COMPATIBLE INTELLIGENT DEVICES NOTE: "A" suffix indicates ULC-Listed model. FWSG Wireless SWIFT Gateway: Addressable gateway supports wireless SLC devices. Not appropriate for ULC applications. See DN-60820. FCO-951/-IV FlashScan, Addressable intelligent multi-criteria smoke sensors, photo, carbon monoxide, fixed temperature heat detector and infra-red (IR). ULC: FCO-951A1-IV FPC-951. FlashScan, Combined photoelectric and carbon monoxide sensor. ULC: FPC-951A. FSCO-951. FlashScan, Addressable carbon monoxide sensor. ULC: FSCO-951A. FPTI-951, FPTI-951-IV: Addressable intelligent multi-criteria photo- electric, thermal and IR sensors. ULC: FPTI-951A, FPTI-951A-IV. FS-OSI-RlAddressable intelligent single-ended beam smoke detec- tor. ULC: FS-OSI-RIA. FSP-951: White, low-profile intelligent photoelectric sensor, FlashScan only. ULC: FSP-951A. FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor. ULC: FSP-951A-IV FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FlashScan only. ULC: FSP-951TA. FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed-temperature thermal device. ULC: FSP-951TA-IV. FSP-951 R: White, low-profile intelligent photoelectric sensor, remote test capable. For use with DNRIDNRW. FlashScan only. ULC: FSP- 95RA FSP-951 R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable. FlashScan only. ULC: FSP-95RA-IV, for use with DNRA. FST-951: White, low-profile intelligent 135°F fixed thermal sensor, FlashScan only. Must be mounted to one of the bases listed below. ULC: FST-951 A. See DN-60975. FST-951-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, FlashScan and CLIP. Must be mounted to one of the bases listed below. ULC: FST-951A-IV. FST-951R: White, low-profile intelligent rate-of-rise thermal sensor, FlashScan only. Must be mounted to one of the bases listed below. ULC: FST-951A FSP-951 R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable. FlashScan only. ULC: FSP-95RA-IV, for use with DNRA. FST-951H-IV: Ivory, low-profile intelligent 190°F thermal sensor, FlashScan and CLIP. Must be mounted to one of the bases listed below. ULC: FST-951HA-IV. FSV-951, FSV-951 R:White, intelligent high-sensitivity photoelectric smoke detector. ULC: FSV-951A, FSV-951RA FSV-951-IV, FSV-951 R-IV Ivory, intelligent high-sensitivity photoelec- tric smoke detector. ULC: FSV-951A-IV, FSV-951 RA-IV. VEP-AOO-P-NTF: Intelligent aspiration smoke detector with LED dis- play, 4 pipes, covers up to 21,520 square feet. See DN-61029. UL/ ULC Listed. VEP-A10-P-NTF: Intelligent aspiration smoke detector with LED and LCD display, 4 pipes, covers up to 21,520 square feet. See ON- 61029. UIJULC Listed. VEP-A00-1 P-NTF: Intelligent aspiration smoke detector with LED display, single pipe, covers up to 10,760 square feet. See ON-6 1029. UL/ULC Listed. VEU-AOO-NTF: Intelligent aspiration smoke detector with LED dis- play, 4 pipes, covers up to 69,965 square feet. See DN-6 1034. ULJ ULC Listed. VEU-A10-NTF: Intelligent aspiration smoke detector with LED and LCD display, 4 pipes, covers up to 69,965 square feet. See ON- 61034. ULJULC Listed. VEA-040-AOO-NTF: Intelligent aspiration with LED display, 40 point- addressable detection points. Covers 36,000 square feet. See ON- 61036. UL/ULC Listed. VEA-040-A1O-NTF: Intelligent aspiration with LED and LCD display, 40 point-addressable detection points. Covers 36,000 square feet. See DN-6 1036. ULIULC Listed. DNR: InnovairFIex low-flow non-relay duct-detector housing. ULC: DNRA. (Order FSP-951 R(A) separately.) See DN-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN- 60429. B224RB-WH: White, low-profile relay base. See DN-60054. ULC: B224RBA-WH. B224RB-IV: Ivory, plug-in System Sensor relay base. ULC: B224RBA-IV. B224B1-WH: White, isolator base for low-profile detectors. See DN- 60054. ULC: B224B1A-WH. B224B1-IV: Ivory isolator detector base. ULC: B224B1A-IV. B300-6: White, standard flanged low-profile mounting base. (For 10- pack order 13300-6-13P.) ULC: B300A-6. B300-6-IV: Ivory, standard flanged low-profile mounting base. ULC: B300A-6-IV. B501-WHITE: European-style, 4 (10.16 cm) base. See DN-60054. (For 10-pack order B501-WHITE-BP.) ULJULC listed. B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed. B200S-WH: White, intelligent programmable sounder base, capable of producing a variety of tone patterns including ANSI Temporal 3. Compatible with synchronization protocol. See DN-60054. ULC: B200SA-WH. B2005-IV: Ivory intelligent, programmable sounder base. ULC: B200SA-IV. B200SCOA-WH: White intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO detectors. Based on B200SA. ULC listed. Page 6 of 9- ON-TIll IN • 12120/2020 B200SCOA-IV: Ivory intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO detectors. Based on B200SA. ULC listed. B200S-LF-WH: White, low-frequency version of B200S. See DN- 60054. B200S-LF-IV: Ivory, low-frequency version of B200S. B200SR-WH: White intelligent programmable sounder base, Tem- poral 3 or Continuous tone. For retrofit installations replacing B501BH series bases. See DN-60054. ULC: B200SRA-WH. B200SR-IV: Ivory intelligent programmable sounder base, Temporal 3 or Continuous tone. For retrofit installations replacing B501 BH series bases. ULC: B200SRA-IV. B200SR-LF-WH: White, low-frequency version of B200SR. See ON- 60054. B200SR-LF-IV: Ivory, low-frequency version of B200SR. FMM-1(A): FlashScan monitor module. See DN-6 720. FDM-1(A): FlashScan dual monitor module. See DN-6 720. FZM-1(A): FlashScan two-wire detector monitor module. See ON- 6720. FMM-101(A): FlashScan miniature monitor module. See DN-6 720. FTM-1(A): Firephone Telephone Module connects a remote fire- fighter telephone to a centralized telephone console. Reports status to panel. Wiring to jacks and handsets is supervised. See DN-6989. FCM-1(A): FlashScan control module. See DN-6 720. FCM-1-REL(A): FlashScan releasing control module. See ON- 60390. FRM-1(A): FlashScan relay module. See ON-6 720. FDRM-1(A): FlashScan dual monitor/dual relay module. See ON- 60709. NBG-12LX: Manual pull station, addressable. See ON-6726. N-MPS series: Manual pull stations, addressable and conventional. For use in Canada only. See DN-5497 and DN-60629. ISO-X(A): Isolator module. See DN-2243. ISO-6(A): Six fault isolator module. See DN-60844. XP6-C(A): FlashScan six-circuit supervised control module. See ON-6924. XP6-MA(A): FlashScan six-zone interface module; connects intelli- gent alarm system to two-wire conventional detection zone. See DN- 6925. XP6-R(A): FlashScan six-relay (Form-C) control module. See ON- 6926. XP10-M(A): FlashScan ten-input monitor module. See DN-6923. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB-4 Series Enclosure: NFS2-640 mounts in a standard CAB-4 Series enclosure (available in four sizes, "A" through "D"). Backbox and door ordered seperately; requires BP2-4 battery plate. A trim ring option is available for semi-flush mounting. See DN-6857. EQ Series Cabinets: EQ series cabinets will house amplifiers, power supplies, battery chargers and control modules. EQ cabinets are available in three sizes, 'B' through "D". See DN-60229.. CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. Also order BB-MB for systems using 100 AH batteries. For a full list of required and optional equipment, see ON- 60688. CHS-4: Chassis for mounting up to four APS-613s. CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers or one AMG-E and one AA-30. DP-113: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2/DAX series or AA-series amplifier. NFS-LBB: Battery Box (required for batteries larger than 26 AH). NFS-LBBR: Same as above but red. CHS-BH1: Battery chassis; holds two 12.0 AH batteries. Mounts one the left side of DAA2 chassis. See DN-7046. Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC-EM and a DVC-KD (optional); and the right side houses a CMIC-i microphone and its well (optional). See DN-7045. Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC-EM mounted on a half-chassis and one NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes CMIC-1 microphone. ADDR Series doors with two-tier visi- bility are available for use with the CA-2 configuration: ADDR-134, ADDR-C4, ADDR-D4 (below). CFFT-1: Chassis to mount firefighter's telephone and one ACS annunciator in a CAB-4 row. Includes TELH-1 firefighter's handset for the DVC-EM, chassis, phone well and mounting hardware. Order DP-CFFT dress panel separately. DP-CFFT: CFFT-1 dress panel. Requires BMP-1 if no ACS annunci- ator is installed. ADDRB4*: Two-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-134 backbox with the ADDR-134. See DN-7045, DN-6857. ADDRC4*: Three-tier-sized door, designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See ON-7045, DN-6857. ADDRD4*: Four-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-D4. See ON-7045, DN-6857. * Note: Use ADDR-B4/C4/D4 when CA-2 chassis is installed in top two rows with NCA-2 or BP-CA2. Use standard door when CA-2 is not installed in top two rows. For additional configuration information, see the DVC application guide on http://esd.notifier.com. DPA-1: Dress panel, used with the CA-1 chassis when configured with a DVC-EM, DVC-KD, and CMIC-1. See DN-7045. DPA-2B: Dress panel used with CA-2 chassis assembly. VP-2B: Dress panel, required when CA-2 chassis is installed in the top two cabinet rows. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMlC- 1 is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. See DN-7045. BP-CA2: Blank plate for CA-2 chassis. SEISKIT-CAB: Seismic mounting kit. Required for seismic-certified applications with NFS2-640 and other equipment mounted in CAB-4 Series Enclosures. Includes battery bracket for two 26 AH batteries. SElSKlT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. BACKBOXES NOTE: "C" suffix indicates ULC-Listed model. ABF-1 B(C) Annunciator Flush Box. ABF-i DB(C) Annunciator Flush Box with Door. ABF-213 Annunciator Flush Box ABF-2DB/C Annunciator Flush Box with Door ABF-4B Annunciator Flush Box ABS-1 TB(C) Annunciator Surface Box ABS-1 B(C) Annunciator Surface Box ABS-213 Annunciator Surface Box DN-71 11:N • 12/20/2020 - Page 7 of 9 I 11 I ABS-2D(C) Annunciator Surface Box ABS4D(C) Annunciator Surface Box BB-UZC: Backbox for housing the UZC-256 in applications where the UZC-256 will not fit in panel enclosure. Black; for red, order BB- UZC-R. OTHER OPTIONS 411: Slave digital alarm communicator. See DN-6619. 411UDAC: Digital alarm communicator. See DN-6746. IPDACT-212UD, IPDACT Internet Monitoring Module: Connects to primary and secondary DACT telephone output ports for Internet communications over customer-provided Ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. See DN-60408. IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 series chassis. Use IPENC for external mounting applications. IPSPLT: Y-adapter option allow connection of both panel dialer out- puts to one IPDACT-212UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red. For Black order IPENC-B. HWF2V-COM: LIE Digital Cellular Fire Alarm Communicator and Internet Panel, Verizon LTE / IP. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Con- nects to the primary and secondary. ports of a DACT. See DH-62010. (For Canadian applications order IPGSM-4GC. See DH-60771.) HWF2A-COM: LTE Digital Cellular Fire Alarm Communicator and Internet Panel, AT&T LTE I IP. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Con- nects to the primary and secondary ports of a DACT. (For Canadian applications order IPGSM-4GC. See DH-60771.) NOTE: For other options including compatibility with retrofit equipment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. Page 8 of 9— DN-71 11:N • 12/20/2020 SPECIFICATIONS SYSTEM CAPACITY Intelligent Signaling Line Circuits .....................1 expandable to 2 Intelligent detectors .................................................159 per loop Addressable monitor/control modules .....................159 per loop Programmable software zones.................................................99 Special programming zones.....................................................14 LCD annunciators per CPU2-640/-640E and NCA-2 (observe power).....................................................32 ACS annunciators per CPU2-640/-640E ..................................32 addresses x 64 points ACS annunciators per NCA-2 ...... 32 addresses x 64 or 96 points NOTE: The NCA-2 supports up to 96 annunciator address points per ACM-24AT/-48A. ELECTRICAL SPECIFICATIONS Primary input power: - CPU2-640 board: 120 VAC, 50/60 Hz, 5.0 A. - CPU2-640E board: 220/240 VAC, 50/60 Hz, 2.5 A. Current draw (standby/alarm): - CPU2-640(E) board: 0.250 A. Add 0.035 A for each NAC in use. - KDM-R2: 0.100 A. - LEM-320: 0.100 A. Total output 24 V power: 6.0 A in alarm. NOTE: The power supply has a total of 6.0 A. of available power. This is shared by all internal circuits. See Installation Manual for a complete cur- rent draw calculation sheet. Standard notification circuits (4): 1.5 A each. Resettable regulated 24V power: 1.25 A. Two non-resettable regulated 24V power outputs: —1.25 A. —0.50 A. Non-resettable 5V power: 0.15 A. Battery charger range: 18 AH —200 AH. Use separate cabinet for batteries over 26 AH. Float rate: 27.6 V. CABINET SPECIFICATIONS Systems can be installed in CAB-4 Series cabinets (four sizes with various door options, see DN-6857). Requires BP2-4 Battery Plate. SHIPPING WEIGHT CPU2-640/-640: 14.3 lb (6.49 kg). CPU2-640/-640E: 14.55 lb (6.60 kg). TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it Iso 9001 111111110116 & MNFP11l OtJA1ITY SYSTEMS is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the basic NFS2-640 con- trol panel. In some cases, certain modules may not be listed by cer- tain approval agencies, or listing may be in process. Consult factory for latest listing status. ULJULC Listed: S635. ULC Listed: S527-11 FM Approved. MEA: 128-07-E. Fire Dept. of New York: #6212. CSFM: 7165-0028:0243. City of Chicago. City and County of Denver. CCCF listed. Marine Applications: Marine approved systems must be configured using components itemized in this document. (See Main System Components, in "Product Line Information.) Specific connections and requirements for those components are described in the instal- lation document, PN 54756. When these requirements are followed, systems are approved by the following agencies: US Coast Guard 161.002/50/0, 161.002/55/0 (Standard 46 CFR and 161 .002). Lloyds Register 11/600013 (ENV 3 category). American Bureau of Shipping (ABS) Type Approval. NOTE: For information on marine applications, see DN-60688. STANDARDS The NFS2-640 complies with the following UL Standards and NFPA 72, International Building Code (IBC), and California Building Code (CBC) Fire Alarm Systems requirements: UL 864, 9th Edition (Fire). UL 1076 (Burglary). UL 2572 (Mass Notification Systems). (NFS2-640 version 20 or higher.) ULC-S527-1 1 Standard for the Installation of Fire Alarm Sys- tems. LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). PROPRIETARY (Automatic, Manual and Waterflow). Not applicable for FM. EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Network). IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). CBC 2007 (Seismic). I I NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. M specifications are subject to change without notice. NOTIFIvENET' ONYXWorks"' and SWIFTr are all trademarks at and FlashS. earnS. NOTIFIES, ONYX®. VerFse® Tunis, and VIENW are at regisNred trademarks ol Honeywell international Inc 02019 by Honeywell International Inc. All rights reseored unauthorized ascot flas doca- meal is strictly prolrrted Country of Origin: USA NOTI Fl ER® by Honeywell DN-6881:A1 - A-35 0 NOTIFIER® by Honeywell I LCM.320 and LEM.320 Loop Control and Expander Modules General The LCM-320 Loop Control Module and the LEM-320 Loop Expander Module provide NOTIFIER's ONYX® Series of Fire Alarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). The ONYX® Series NFS-640/NFS2-640 supports one LEM-320; the NFS-3030/NFS2-3030 supports up to five LCM- 320s and five LEM-320s. The LEM-320 module is used to expand the NFS-640/NFS2-640 to a second loop, and to expand each LCM-320 used on the NFS-3030/NFS2-3030 - each NFS-30301NFS2-3030 LCM-320 supports an expansion LEM-320. Features Up to 12,500 feet (3,810 m) on a Class B (Style 4) SLC loop (twisted-unshielded). Built-in degraded mode increases survivability. Very simple installation - plug-in style. Permits multiple loops in small enclosure. Specifications Voltage: 24 VDC nominal, 27.6 VDC maximum. Loop Control Module Loop Expander Module Maximum loop length: The maximum wiring distance of an SLC using 12 AWG (3.1 mm2) twisted-pair wire is 12,500 feet (3810 m) per channel. For a twisted-unshielded pair, 12 AWG (3.1 mm2) to 18 AWG (0.78 mm2): - Distance with 12 AWG: 12,500 ft (3,810 m). - Distance with 14 AWG: 8,000 ft (2,438 m). - Distance with 16 AWG: 4,875 ft (1,486 m). - Distance with 18 AWG: 3,225 ft (983 m). - 50 ohms maximum per length of Style 6 & 7 loops. - 50 ohms maximum per branch for Style 4 loop. Maximum current: for LCM-320: 130 mA; for LEM-320: 100 mA; for single SLC loop: 400 mA maximum. NOTE: Maximum short circuit - loop will shut down until short-cir- cuit condition is corrected. Maximum resistance: 50 ohms (supervised and power- limited). Temperature and humidity ranges: This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 270C/60 - 80°F Product Line Information LCM-320: Loop Control Module. Adds SLCs to NFS-3030/ NFS2-3030; NFS-3030/NFS2-3030 supports up to five LCM- 320s and five LEM-320s. LEM-320: Loop Expander Module. Expands each LCM used on the NFS-3030/NFS2-3030; expands NFS-640/NFS2-640 to two loops. Agency Listings and Approvals The listings and approvals below apply to the basic LCM-320 and LEM-320. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL: S635 ULC:S635/CS118 FM Approved CSFM: 7165-0028:224, 7170-0028:223 (LCM/LEM-320 with NFS-3030/NFS2-3030). 7165-0028:214, 7170- 0028:216 (LEM-320 with NFS-640). 7165-0028:243, 7170- 0028:244 (LEM-320 with NFS2-640). FDNY: COA#6025 (LEM-320 with NFS2-640) FDNY: COA#6026 (LCM-320/LEM-320 with NFS2-3030) City of Denver Hong Kong DN-6881:A1 • 06/05/2009 - Page 1 of 2 1 I I FLASHSCAN® and NOTIFIER® are registered trademarks of Honeywell International Inc. 0 2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I iso ooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MOINEERINS &MRNUFACTURINC All specifications are subject to change without notice. I QUALITY SYSTEMS Made inthe U.S. A. For more information, contact Notifier. Phone: (203) 484-7161 FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6881 Al • 06/05/2009 I DN-60548:D NOTIFIER® by Honeywell General . LCD2-80 Liquid Crystal Display Terminal Mode/ACS Mode Annunciator The LCD2-80 is a backlit LCD annunciator for the NOTIFIER fire alarm control panels, or network control annunciators that support the 80-character display format. LCD2-80s may be connected onto the four-wire EIA-485 terminal port. The LCD2-80 mimics the display of NFS2-640, NFS2-3030, NFS-320, NCA-2 and legacy panels that supported the LCD- 80/LCD-80TM. The NFS2-3030 and the NCA-2 also support LCD2-80s when set for LCD-80 supervision. Up to 32 LCD2- 80s can annunciate and provide remote reset, acknowledge, drill and silence of the control panel from remote locations. Features 80-character backlit Liquid Crystal Display (20 characters x 4 lines). Display mimics panel or NCA: - Event message. - 20 characters for point label. - 12 characters for extended label. - Time, date and point address. Control switches for System Acknowledge, Signal Silence Drill and System Reset. LEDS for general oft-normal events with UL 864 9th Edition Panels. NOTE: The LEDs are only applicable when used with UL 864 Ninth Edition listed panels: NFS-320, NFS2-640, NFS2-3030, and NCA-2. ACS mode option for annunciation of user selected points. (VeriFire Tools 6.90 or higher required to program points.) Up to 6000 foot segments between units. Local piezo sounder with alarm/trouble resound. Displays all analog, addressable points. Displays device type identifiers. Displays device and zone custom alpha labels. IN REMOTE ANNUNCIATOR ALL SYSTEMS NORMAL 0800 03I1,5/1.0 ALARM i rt i I I ty - - SUPERVISORY SYSTEM TROUBLE POINT DISABLE SIGNAL SILENCE OTHER ACKNOWLEDGE SIGNAL SILENCE RESET - DRILL LAMP TEST El LCD2-80 mounts with any CHS-4 chassis slot. Slide-in label can be customized. Flush/surface/panel mount option. LCD2-80 displays time, date, and custom messages received from the compatible panel or network annunciator. LCD2-80 is 8.25" (20.96 cm) high, 4.375" (11.11 cm) wide, and 1.75' (4.45 cm) deep. Up to 32 LCD2-80s may be used on one EIA-485 circuit. NOTE: Must have sufficient regulated 24 volt power. 6,000 ft (1828.8 m) Maximum wire length between each LCD2-80 EIA-485 (2 wires) 24 VDC (2 wires) EIA-485 return (2 wires) NFS-320, NFS2-640, NFS2-3030, or NCA-2 connecting to LCD2-80 DN-60548:D.3/2/17—Page 1ot 2 The ABF-1 DB Backbox may not be listed by certain approval agencies, or listing may The ABF-1 DB is a semi-flush-mount backbox for the NOTI- be in process. Consult factory for latest listing status. • FIER LCD2-80 Series Annunciator. The ABF-1 DB mounts one UL Listed: S635. I LCD2-80. It includes an attractive smoked-glass door with LJLC Listed: S527-11. NOTIFIER keylock. FDNY: COA# 6212, 6211. Dimensions, BOX only: 9.938 (25.24 cm) high, 4.625 CSFM: 7165-0028:0243, 7165-0028-0224. 1 (11.75 cm) wide, 2.5 (6.35 cm) deep. FM Approved. I Dimensions, DOOR only: 10.713" (27.21 cm) high, 6.0 (15.24 cm) wide, 0.75 (1.9 cm) deep. I Related Options "C" suffix indicates ULC-Listed model. ABF-1 DB(C): Semi-flush box with alternative smoked-glass I door, any keylock. ADP-4B: Annunciator dress plate, black. Allows panel mount- ing of up to four LCD2-80 modules in a CAB-4 Series cabinet. ABF-1B(C): Annunciator flush box, 9.938" (25.24 cm) high, I 4.625 (11.75 cm) wide, and 2.5" (6.35 cm) deep. Order AKS- 1 B key switch and APJ-1 B phone jack if desired. Can also be mounted in ABF-213 or ABF-413 annunciator backboxes. I ABS-1TB(C): Deep surface backbox (mounts one LCD2-80). ABS-1 B(C): The Annunciator Surface Box-lB (black) provides for the remote mounting of one annunciator module in a sur- face-mount enclosure. Knockouts are provided for use with 1/ 2" (1.27 cm) conduit. The annunciator mounts directly to the ABS-1 13/C without a dress plate. 8.5 (21.59 cm) high x 4.5" (11.43 cm) wide x 2" (5.08 cm) deep. NOTE: The ABS- 1B will not support the installation of the AKS- lB Annunciator Key ' Switch. ABS-2B: Annunciator surface box, 8.5 (21.59 cm) high x 8.92 (22.66 cm) x 2" (5.08 cm) deep. Knockouts are provided for use with 1/2 (1.27 cm) conduit. The annunciators mount I directly to the ABS-213 without a dress plate. ABS-211)(C): Annunciator backbox, surface, black. LJL/ULC Listed. I ABF-2B: Annunciator flush box, 9.938" (25.24 cm) high x 9.188" (23.34 cm) wide x 3.75" (9.525 cm) deep. Includes a painted metal trim plate [11(27.94 cm) high x 10.625' (26.99 cm) wide] and adhesive-backed annunciator label. ABF-2DB(C): Annunciator semi-flush mount backbox. Black with a smoked glass door with a keylock. ABS-4D(C): The ABS-4D/C is a semi-flush-mount backbox for the ACS Series Annunciators. It mounts up to four modules, and can also accommodate the NCA-2 network annunciator, using the NCA-2 Retro Kit (NCA-2Retro); the NCA-2 is mounted in the center position with a blank plate (BMP-1) mounted on each side. Black with an attracted smoked glass door and keylock. The ABS-4D is hinged on the bottom for sta- bility. AKS-1 B: Key Switch (black) to enable/disable controls when mounted in ABF-1B orABS-1TB. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications Notifier® and VeriFire® Tools are registered trademarks of Honeywell International Inc. ©2017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO ooi We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEIRINS A IYANUFACTURINS All specifications are subject to change without notice. QUALITY SYSTEMS Country otOngin:USA For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- DN-60548:1) • 3/2/17 DN-60686:A1 0 NOTIFIER® Communicator Transmitter by Honeywell General UDACT-2 Universal Digital Alarm The Universal Digital Alarm Communicator Transmitter (UDACT- 2) is designed for use on Notifier Fire Alarm Control Panels and on the NCA-2 Network Control Annunciator. When used in con- junction with the NCA-2 network control annunciator, the UDACT-2 can report the status of all control panels on NOTl.FIRE.NETTM. The UDACT-2 transmits system status to UL listed Central Station Receivers via the public switched tele- phone network. The UDACT-2 can be installed in the panel cab- inet or remotely in a separate enclosure. NOTE: The UDACT-2 can also be used with legacy panels. Please refer to the UDACT-2 manual for more information. The UDACT-2 upload/download programming and firmware updates are accomplished with VeriFire Tools. Refer to the Pro- gramming Section for further details. The UDACT-2 is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Off-Normal, Supervisory, Bell Trouble, Low Battery, and AC Fail. The UDACT-2 is capable of transmitting all of the zone and point sta- tus associated with each panel. When the UDACT-2 is used with the NFS-3030, NFS2-3030, and NCA-2 it is capable of reporting up to 2,040 points. Report- ing may be in the form of points or zones (refer to the UDACT-2 manual for specific reporting parameters). Points transmitted may be programmed for a variety of types, including fire, water- flow, supervisory, etc. NOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Ademco Contact ID format. See chart on page 2 for compatible receivers. Features Programmable with VeriFire Tools version 6.60 or higher, allowing the UDACT-2 programming to be uploaded/down- loaded and saved. Maximum of 14 point trouble messages transmitted per hour. Dual phone lines with line voltage detect. Compact in size: 6.75 x 4.25 (17.145 x 10.795 cm). USB port for upload/download programming. Manual Test Report function. Manual Transmission Clear function. Mounts in a separate enclosure (ABS-8RB or UBS-1 B/R). Communicates vital system status including: - Independent zone fire alarm. - Independent zone non-fire alarm. - Independent zone trouble. - Independent zone supervisory. - AC (mains) Power Loss (programmable). - Low Battery and Earth Fault. - System Oft-Normal. - 12 or 24 hour test signal. - Abnormal Test Signal per new UL requirements. - EIA-485 Communication Bus Failure. Annunciation of UDACT-2 Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kis- soff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. UDACT-2 Open Collector relay driver for Total Communications Failure or UDACT-2 trouble. Real-time clock. Extensive transient protection. EIA-485 interface to host panel. Programming The UDACT-2 programming is created and downloaded using VeriFire Tools. This enables the unit to be programmed prior to installation, be easily modified, and saved either online or offline. A printed report with point or zone information can be generated from VeriFire Tools for an ONYX Series panel or net- work annunciator. The point report consists of the central station point address, ACS point, ACS point function, panel label, panel point, type code, custom and extended label, alarm verification, walktest participation, presignal, and PAS information. The zone report consists of a grid with the central station point address, ACS point address, source, ACS point function, custom label and panel label. This report may be sent to the Central Station for their records. VeriFire Tools also supports upgrading the UDACT-2 operating firmware. DN-60686:A1 • 4/2/12 - Page 1 of 2 1 I Communication Formats UL Listed Receivers Ademco Contact ID The chart below shows UL listed receivers compatible with the ' 4+2 Standard UDACT-2. A check in the protocol column indicates the receiver I SIA supports that protocol. NOTE: Ademco Contact ID must be used for independent zone reporting. I 4+2 Ademco Type Mode Feature Standard Contact Ademco Contact ID format - only Use Type Mode to identify Receiver 1800/2300 ID SIA reports to Central Station as: Ademco 685 (1) V V I Fire Alarm 'Burglary Supervisory '24 hour Non-Burglary Ademco MX8000 (2) V V V Pull Station • High Temperature Silent-Knight 9500 (3) V V V I Heat Detector 'Low Temperature Waterfiow • Low Water Pressure Silent Knight 9800 (4) V V V Duct Detector • Low Water Level I Flame Sensor • Pump Failure FBI CP220FB (5) V V V Smoke Zone Osborne Hoffman 2000E (6) V V Electrical Specifications Radionics 6600 (7) V V I Standby current: 40 mA. SurGard MLR2 (8) V V Current while communicating: 75 mA. Maximum current while communicating and with open collector SurGard System III (9) V V I output activated: 100 mA. SurGard MLR-2000 (10) V Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. Agency Listings and Approvals With 685-8 Line Card with Rev 4.4d software I With 124060V206B and 124063 Line Card Rev B In some cases, certain modules may not be listed by certain With version V2.4 Receiver & 126047 Line Card Rev G approval agencies, or listing may be in process. Consult factory for latest listing status. With 124077V2.00 Receiver &126047 Line Card Rev M I UL/ULC Listed: S635 (5) With software V3.9 FM Approved (6) With V7301 Receiver S/W CSFM: 7165-0028:0243 (NFS2-640/320), 7165-0028:0224 With 01 .01 .03 Receiver SIW & Line Card 01 .01 .03 (NFS23030) With software V'11.86 I FDNY: COA#6085, COA#6098 With sotware V1.72 Ordering Information With DSP4016 and V1.6 Line Card I UDACT-2: Universal Digital Alarm Communicator Transmitter. Includes operating and programming instructions, and mounting hardware. MCBL-7: DACT phone cord, 7 ft (2.13 m) long (two required). I ABS-8RB: Metal enclosure for externally mounting UDACT-2 up to 6,000 ft./1828.8 m from host FACP. 9.94" H x 4.63' W x 2.50" D (cm: 25.248 H x 11.760W x 6.350 D). UBS-1B: Metal enclosure with solid door, Black. I UBS-1 BR: Metal enclosure with solid door, Red. R-1 OE: SPDT Form-C relay. Contacts rated for 10 A @ 115 VAC. Connects to open collector relay driver. I R-20E: DPDT Two Form-C relays. Contacts rated for 10A @ 115 VAC. Connects to open collector relay driver. NOTI.FIRE.NETTM is a trademark and Notifier@ is a registered trademark of FBD-1: Ferrite bead kit. Use for remote mounting only. Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use 1 of this document is strictly prohibited. I This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. 0-1:02I_I_ We cannot cover all specific applications or anticipate all requirements. INClNEIfllNL A MANUFACERING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. I For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com I Page 2 of 2— DN-60686:A1 • 4/2/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:0243 . Page 1 of 4 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models NFS2-640, NFS-320/C (R), and NFS-320SYS fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), manual, automatic, waterfowl and sprinkler supervisory services. Also suitable for releasing service, Process Management and Emergency Voice/Alarm communication System *• Model numbers may be followed by an "R" suffix representing the enclosure color being red. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ACM-8R, -I6AT, -32A, -24A1, -48A; Annunciator Control Modules ACPS-61 0, AMPS-24; Addressable power supply/charger ADP-413, -A4, -1, -2, DP-DlSP2; Dress Panel AEM-I6AT, -32A, -24AT, -48A; Annunciator Expander Modules AFM-16A, -16AT, -32A; Annunciator Fixed Modules AKS-1 B; Annunciator Key Switch APS2-6R; Power supply BB-100, -200, NFS-LBB/-LBBR; Battery Boxes BGRA-SCS, BGRB-SCS; Smoke Control Station BMP-1; Blank Module BP-4, BP2-4; Battery Dress Plates CAB-3/4 Series; Enclosure CAB-RP, CAB-RPR; Cabinets CEF-SCS; Smoke Control Station CHS-4, CHS-4N, CHS-4L; Chassis CPU2-640, CPU-320SYS; CPU Board CRT-2; Display Terminal DP-1B; Blank Panel DPA-1A4/1/2, DP-D1SP2; Dress Panel DPI-232; Panel Interface DR-A4, DR-A413, DR-A4BR, DR-A4R; Door Assembly DR-AA4, DR-AA413, DR-AA4BR, DR-AA4R; Door Assembly DR-B3F; Door Assembly DR-134, DR-13413, DR-B4BR, DR-134R; Door Assembly DR-C4, DR-C4B, DR-C4BR, DR-C4R; Door Assembly DR-04, DR-D4B, DR-D4BR, DR-D4R; Door Assembly *Rev. 10-29-13 gt This listing is based upon 'technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division I Listing No. 7165-0028:0243 I Page 2of4 EQ Series; Cabinets I EQBB-B4, EQBB-C4, EQBB-04; Backbox Assembly EQDR-B4, EQDR-C4, EQDR-D4; Door Assembly FCM-1, FCM-1-REL; Releasing Control Module I FCPS-24S6, -24S8; Field Charger/Power Supply FDM-1; Dual Monitor Module FDRM-1 :Multiple Module with two Relay Outputs FDU-80/-80G; Remote Annunciator I FIRSTVISION-LCD/ENC; Interactive Firefighters' display/enclosure FRM-1; Relay Module FTM-1; Control Module I FZM-1, FMM-1, FMM-101; Monitor Modules HS-NCM-W/-MF/-SF/-WMF/-WSF/-MSSF; High Speed Network Control Modules IPDACT-2/-2UD; IP Fire Alarm Communicator ' ISO-X; Isolator Module KAPS-24, CPS-24; Power Supply KDM-R2; Keyboard Display Module LCD-80, -160; Annunciators I LCD-80TM; Annunciator Terminal Module LCD LCD2-80; Remote Annunciator LDM-32/-E32/-R32; Lamp Driver Module I LEM-320/ELEM-320; Loop Expander Module NBG-I2LRA; Agent Releasing Abort Station NBG-12LX; Addressable Manual Pull Station I NCA, NCA-2; Network Communication Annunciator NCM-W, -F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station NCS5-W-ONYX, NCS5-F-ONYX; Network Control Station I NFS-LBB/NFS-LBBR; Battery Box/Red NFS-320SYS; Chassis NFV-25/50, NFV-25/50ZS/ZST; Voice Evacuation Control Panels I NFV-25/50DA, NFV-25/50DAZS; Distributed Audio Panels ONYXWorks-EW/-NW-/NF/-HNW/-HNMF/-HNSF/-TS/-EW-TS/-NF-TS/-HW-TS/ -HNMFT/-HNSFT/-HNWT; PC workstation for NOTI .FlRE.NET, Wire/Fiber/ with Touch screen monitors I PRN-6; Printer RKS-S; Remote Security Key Switch RPT-W, -485W; Repeater Wire I RPT-F; Repeater Fiber RPT -485FW; Repeater Fiber/Wire RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station I SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-AA4R; Backbox Assembly SBB-134, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly - *Rev. 10-29-13 gt T' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/pr other I Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7165-0028:0243 Page 3 of 4 SCE-8; Smoke Control Expander SCS-8L; Smoke Control Lamp Driver Station SCE-8L; Smoke Control Expander Lamp SCS-8; Smoke Control Station STS-11; Security Tamper Switch TM-4; Transmitter Module TR-A4/-B3N/-B4/-C4/-D3N/-D4; Trim Ring UDACT, UDACT-2; Universal DACT UZC-256; Universal Zone Coder VP-2B; Dress Panel XP5-C/-M; Transponder Modules XP6-C; Supervised Control Modules XP6-MA; Six Zone Interface Modules XP6-R; Six Relay Control Modules XP10-M(A); Ten Input Monitor Modules XPM-8L; Transponder Monitor Modules The following models are intended for use on NFS2-640 only: AA-30, -100, -120; Amplifiers ACT-1, -2, -41 -25, -70; Audio Coupling Transformer ADDR-B4/-B4R/-C4/-C4RI-D4/-D4R; Door Assemblies AMG-E; Audio Message Generator AVL-11; Audio Voice Link BDA-25V/-70V; Backup Digital Audio Amplifiers CHS2-M2, CA-1, CA-2; Chassis CMIC-1, CMIC-RP; Microphone Assembly DAA-5025/-5070; Digital Audio Amplifiers DAA-5025F/DAA-50255F; Digital Audio Amplifiers DAA-5070F/DAA-50705F; Digital Audio Amplifiers, Fiber Mode DAA-75 Series; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-75255F; Digital Audio Amplifiers DAA2-5025/-5070/-7525; Digital Audio Amplifiers DAX-3525/-3570/-5025/-5070; Digital Audio Amplifiers DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module DVC; Digital Voice Command DVC-EM/-EMF/-EMSF; Digital Voice Command Extended Memory Module DVC-RPU; Remote Paging Unit FFT-7, -7S; Fire Fighter's Telephone FHS; Fireman's Handset FPJ; Fireman's Phone Jack RM-1, RM-1 SA; Remote Microphone *Rev. 10-29-13 gt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7165-0028:0243 Page 4 of 4 TELH-1; Telephone Assembly XPlQ; Transponder Quad Intelligent Audio INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING:. Listee's name, model number, electrical ratings, and UL Label APPROVAL: Listed as fire alarm control units suitable for use in high-rise applications when used in conjunction with separately listed compatible initiating and indicating devices. *Control units may be used with Notifier's First Command NFC-50/100 emergency voice evacuation panals (CSFM # 6911-0028:0265). This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 Seconds. 2. Combined with 7170-028:244 *Rev. 10-29-13 gt %ØT This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division I I I I 111 I I NOTIFIER® I by Honeywell PSE-6/PSE-1 0 Series 6/10 Amp, 24 Volt Power Supply Expanders General The PS Series is a remote power supply line from NOTIFIER. The PSE-6(C)(E) is a 6 amp and the PSE-10(C)(E) is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync pro- tocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. The PSE-6E and PSE-10E are models rated for 240V operation. Features Up to five (6 amp model) or seven (10 amp model) inde- pendently-configurable, power-limited output circuits for: - Class B and/or Class A NACs - Class B and/or Class A resettable or non-resettable 24V auxil- iary power - door holder power Converts from Class B to Class A wiring without losing any out- puts using the ZNAC-PS converter card (sold separately) Optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated power Configurable for ANSI® Temporal 3 or Temporal 4 coded output UL-Listed NAC synchronization using System Sensor®, Whee- lock®, Gentex®, or AMSECO® appliances Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet Ability to cascade up to four power supplies Two (6 amp model) or three (10 amp model) fully-isolated input/ control circuits which can be programmed to any output Two Form C normally-closed trouble relays for AC Trouble and General Trouble, Ground Fault relay available on Canadian mod- els only 6 or 10 amp full load output, respectively, with 3 A maximum/cir- cuit Individual NAC power and trouble LEDs for diagnostic efficiency Trouble history modes for diagnostic support Wide range end-of-line supervision value (normal: 2K-27K ohms) Selectable earth fault detection (enable or disable) AC trouble report delay timer Completely configurable via onboard DIP switches, no extra soft- ware required Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion-resistant powder coat chip and scratch-resistant finish Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring Includes integral battery charger capable of charging up to 33 AH batteries Cabinet can house two 7 AH or 18 AH batteries Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire Works with any UL 864 FACP which utilizes an industry-standard reverse-polarity notification circuit Optional devices include addressable control, monitor, and relay modules and power-supervision relay (EOLR-1) Standards and Codes The PSE Series comply with the following standards: NFPA 72 National Fire Alarm Code UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode), 10th Edition UL 1481 Power Supplies for Fire Alarm Systems IBC 2009 (when using SElSKlT-MULTI-1) CBC 2007 (when using SEISKIT-MULTI-1) Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635 (PSE-6/10C) CSFM Approved: 7315-0028:0513 FDNY Approved FM Approved DN-61092:B • 10/8/2020 - Page 1 of 2 Iso ooi 1111 11 IM11116 &MCUF11 QUAlITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-f o.date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIER® and System Sensorfltare registered trademarks of Honeywell International, Inc. Wheelock® is a registered trademark of Cooper Tech- nologies Company. Gentex® is a registered trademark of Gentea Corpora- tion. AMSECO® is a registered trademark of Potter Electric Signal 12 Clintonville Road Company, LLC. ANSI® is a registered trademark of the Americas National Northford, CT 06472 Standards Institute, Inc 203 484 7161 52020 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. www.notifier.com Country of Origin: USA 1 I (@)NOTIFIER by Honeywell SPECIFICATIONS Primary (AC) Power: . PSE-6(C): 120 VAC, 50/60 Hz, 5.OA maximum PSE.1O(C): 120VAC, 50/60 Hz, 6.2Amaximum PSE-6E: 240 VAC, 50/60 Hz, 2.7A maximum PSE-10E: 240 VAC, 50/60 Hz, 3.5A maximum Wire Size: #12-14 AWG with 600 V insulation Command Input Circuit: Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 -16 V) Trouble Contact Rating: 4 A at 24 VDC Output Circuits: 24 VDC filtered, regulated PSE-6: TB8-TB9 - 1A Regulated, 3A special applications; TB10- TB12 - 0.3A Regulated, 3A special applications PSE-10: TB8-TB1I - 1.5A Regulated, 3A special applications; TB12-TBI4 - 0.3A Regulated, 3A special applications 6.0 A (PSE-6) or 10.0 A (PSE-lO) maximum total continuous cur- rent for all outputs Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only Float-charge voltage: 27.6 VDC Maximum current charge: 1.5 A Maximum battery capacity: 18 AH (inside cabinet) Maximum battery charging capacity: 33 AH (external cabinet) Physical: Dimensions: 20.0"H x 14.5W x 3.5"D (cm: 50.8H x 36.83W x 8.9D) Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds (17.7 kg) Ordering Information PSE-6: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure PSE-6C: Same as above, ULC-listed model PSE-6R: Same as PSE-6 with red enclosure PSE-6E: 6.0 A, 240 VAC remote charger power supply in a lock- able, metal enclosure PSE-10: 10.0 A, 120 VAC remote charger power supply in a lock- able, metal enclosure PSE-IOC: Same as above, ULC-listed model PSE-10R: Same as PSE-10 with red enclosure PSE-10E: 10.0 A, 240 VAC remote charger power supply in a lock- able, metal enclosure ZNAC-PS: Optional Class A output converter module FCM-1: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notifica- tion appliances. FRM-1: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch FMM-1: Addressable Monitor Module for one zone of normally open dry-contact initiating devices. Includes plastic cover plate and end- of-line resistor. Module may be configured for either a Class B or Class A IDC. FDM-1: Dual Monitor Module. Same as FMM-1 except it provides two inputs for Class B wiring only FDRM-1: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only. XP6-C: Six-circuit supervised control module XP6-R: Six Form-C relay control module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270: Battery, 12 volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). BAT-12180: Battery, 12 volt, 18AH BAT-12330: Battery, 12 volt, 33AH SElSKlT-MULTI-1: Seismic kit for the FL-PSE Series. Includes bracket and hardware for two 7AH or two 18AH batteries. I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0028:0513 Page 1 of I CATEGORY: 7315-- POWER UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models PSE-6, PSE-6E, PSE-6R, PSE-10, PSE-10E, and PSE-10R Power Supply Expander. Model ZNAC-PS Class A Converter Module. The PSE series are remote power supply and battery charger units which also provide programmable synchronized Class B NAC's. Model Variations: All PSE-6 Models: Maximum 6A Capacity; 5 Class B NAC's; 2 Command Inputs; Trouble and AC Loss Relays All PSE-lO Models: Maximum 10A Capacity; 7 Class B NAC's; 3 Command Inputs; Trouble and AC Loss Relays With Suffix "E": Nominal 240V, 50/60 Hz AC Input Without Suffix "E": Nominal 120V, 50/60 Hz AC Input With Suffix "R": Red Enclosure Without Suffix "R": Black Enclosure Model ZNAC-PS: Optional Class A Conversion Module Refer to listee's printed data sheet for detailed product description and operational considerations. RATING: Models PSE-6 and PSE-6R: 120V AC, 50/60 Hz, 5.OA Maximum Models PSE-6E: 240V AC, 50/60 Hz, 2.7A Maximum Models PSE-lO and PSE-IOR: 120V AC, 50/60 Hz, 6.2A Maximum Models PSE-10E: 240V AC, 50/60 Hz, 3.5A Maximum Model ZNAC-PS: 24V DC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a power supply extender when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 09-16-20 VWW To This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: October 05, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division 6933c0v.jpg DN-69330 • E-205 0 NOTIFIER® by Honeywell Goa General BAT Series Batteries are Power-Sonic brand batteries. BAT Series (or Power-Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. r"W~_ , BAT Series Batteries Sealed Lead-Acid Features Provide secondary power for control panels. Sealed and maintenance-free. Overcharge protected. Easy handling with leak-proof construction. Ruggedly constructed, high-impact case (ABS). Long service life. Compact design. Agency Listings and Approvals The listings and approvals below apply to BAT Series Batter- ies. In some cases, certain modules may not be listed by cer- tain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Recognized Components: MH20845 (Power-Sonic). Ordering Information BAT-1250-BP: 10-unit bulk pack of BAT-1250 (12 V 5 AH). BAT-1270-BP: 5-unit bulk pack of BAT-1 270 (12 V 7 AH). BAT-12120-BP: 4-unit bulk pack of BAT-12120 (12V 12 AH). BAT-12180-BP: 2-unit bulk pack of BAT-12180 (12 V 18 AH). BAT-12260-BP: 2-unit bulk pack of BAT-12260 (12 V 26 AH). BAT-12550: single battery (12 V 55 AH). BAT-121 000: single battery (12 V 100 AH). Part Number Reference & Specifications Part Number Power- Sonic Part Number Battery Description DIMENSIONS Nominal Voltage ______ Nominal Capacity @20hr. rate A. H. Width Depth Height Height over terminal Weight - in. - mm in. mm - in. - mm - in. - mm - lb. kg; BAT-1250 PS-1250 12 5 sealed 3.54 TT 4.21— 107 3.50 1.59 BAT-1270 PS-1270 12 7 sealed 595 151 256 65 3.7 94 36 98 4.8 218 BAT-12120 PS-12120 12 12 sealed 5.95 151 3.86 98 3.7 94 3.94 100 792 359 BAT-12180 PS-12180 12 18 sealed 7.13 181 300 76 659 167 6.59 167 12.6 15.72 BAT-12260 PS-12260 12 26 sealed 65 167 697 177 4.92 125 4.92 125 17 7.71 BAT-12550 PS-1 2550 12 55 sealed 904 230 5.45 138 8.15 207 8.98 228 36 1633 BAT-121000 PS-121000 12 1 100 1 sealed 112 305 6.6 168 8.15 207 8.98 228 68 30.84 I I I DN-6933:D • 02/28/2013 - Page 1 of 2 I Discharge Characteristic Curves at 20°C (68°F) For 6V For 12V Battery Battery 6.5 13.0 NN 5.0 i:: Ic 4.0 r 8.0 1 2 4 6 8 10 20 40 60 2 4 6 810 20 Minutes Hours Discharge Time Effect of Temperature on Capacity 120 0.05 C 110 0.10 C 0.25 C 80 0.50 C 1 60 40 8 20 -40 -30 -20 -10 0 10 20 30 40 50 60 Temperature (°C) PS-121000 Shelf-Life and Storage 100 0 86 C 0 Is C 60 @3 3 40 a Ce 1 Charging not I necessary unles I 100% of capacih - is required. -N 5°C (41 F) ( Charging before use is necessart to help recover - - - - - full capacity. Orargemaytaf I to restore full capacity. Do not 40° 30°C 20C C - - (104°F). _(86°F) .__(6 I reac .(680F)_F_ let batteries 1 ,{ this state. (3 V 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) PS-121000 Discharge Characteristics 14.0 13.0 t 1.2 2.4 6 12 24 36481 2 4 6 810 20 40 Tin 'H h 'I Discharge Time NOTIFIER® is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. M1111011111111 & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6933:1) • 02/28/2013 I i MIN I!!!ii!UIiiIi1I UIIIIilUIIF IHl UI!!iiMIh1 OWIMPArm 111111 uiiuuii••uiiu DN-6720:E FMM-1 (A), FMM-1 01(A), FZM.1 (A) & FDM.1 (A) jNOTIFlER® Monitor Modules with FlashScan® by Honeywell General Four different monitor modules are available for Notifier's intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. FMM-1 (A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 - 99 on CLIP loops. LED flashes green during normal operation (programma- ble option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- FMM-1(A) (Type H) open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), I com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:E 07/30/2015 - Page 1 of 4 FMM.101(A) Mini Monitor Module Temperature range: 32°F to 120°F (0°C to 49°C). Built-in type identification automatically identifies this Humidity range: 10% to 93% noncondensing. 0 IIIUIIILUI IIIUUUI LO LIIe pane. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. 1415 0 1 ADDRESS o 12/ 3 LOOP 3 1 5 0~. "5 j TENS ONES II H I o uJ II.j LQU •o .jll iIl 110 cc I H I IQ: The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, I communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM.1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on FlashScan loops, 01 - 99 on CLIP loops. LED flashes during normal operation; this is a program- mable option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, I communication and I LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Page 2 of 4— DN-6720:E -07/30/2015 Humidity range: 10% to 93% noncondensing Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM4 (A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY Style 0 (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635. ° ULC: S635. FM Approved. CSFM: 7300-0028:0219, 7165-0028:0224, 7165-0028:0243. MEA: 457-99-E. U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NFS2-3030). Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, NFS2-3030). ° Fire Dept. of New York: COA #6121 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030). Product Line Information NOTE: 'A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-101(A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1 (A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. A CAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. I DN-6720:E "07/3012015 - Page 3 of 4 4 DN-6724:B3 FCM-1(A) & FRM.1(A) NOTI Fl ER® Series Control and Relay Modules by Honeywell General FCM-1(A) Control Module: The FCM-1 (A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED 'blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFl). The FCM-1 (A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 - 99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z) Applications The FCM-1(A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScanO releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01 -159). FCM-1 (A) The FCM-1(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1(A) or FRM-1(A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:133 • 2/17/2011 - Page 1 of 2 I Maximum NAC Line Loss: 4 VDC. Contact Ratings for FRM-1 (A) I External supply voltage (between Terminals T10 and Til): Maximum (NAG): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (114.3 mm) high x 4° (101.6 mm) wide x 1.25 (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125' (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded A .5 30 VDC Inductive Coded (L/R=5ms) 1A 30 VDC Inductive (LIR=2ms) Coded .3A 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: "A" suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. FRM-1(A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1(A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document /56-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. I • ULC: S3705 (A version only) FM Approved I . CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 I Notifier5 and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 11111INERINI & MNOFACTINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the u.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- DN-6724:133 • 2/17/2011 Li I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0219 Page 1 of ti CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM1 control modules, and *FDRMI with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. Rev. 10-24-11 mt . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division 0 N.OTIFI ER® by Honeywell FST.951 Series Intelligent Addressable Heat Detectors The NOTIFIER® FST-951 Series intelligent thermal detectors are designed for both performance and aesthetics, and are direct replacements for the FST-851 Series. A new modern, sleek, con- temporary design and advanced thermal technologies make the FST-951 Series ideal for both system operation and building design. The point ID address, set using rotary decimal switches, provide specific detector locations. The series includes a 135°F/57°C fixed-temperature, rate-of-rise, and a 190°F/88°C fixed high-temperature detectors. These thermal detectors provide effective, intelligent property protection in a variety of applications. Detectors are available for both FlashScan® and CLIP applications as designated. Features SLC LOOP: Two-wire SLC loop connection Unit uses base for wiring ADDRESSING: Addressable by device Rotary, decimal addressing (Refer to the NOTIFIER panel manuals for device capacity.) ARCHITECTURE: Designed to meet UL 268 7th Edition Sleek, low-profile, stylish design State-of-the-art thermistor technology for fast response Integral communications and built-in device-type identification Built-in tamper resistant feature Built-in functional test switch activated by external magnet OPERATION: Fixed temperature model (FST-951) factory preset to 135°F (57°C) Rate-of-rise model (FST-951R),15°17 (8.3°C) per minute High-temperature model FST-951H) factory preset to 190°F (88°C) 360°-field viewing angle of the two visual alarm indicators, LEDs blink red in Normal condition and turn on steady red in Alarm • LEDs blink every time the unit is polled MECHANICALS: Sealed against back pressure SEMS screws for wiring of the separate base Designed for direct-surface or electrical-box mounting Plugs into separate base for ease of installation and maintenance Separate base allows interchange of photoelectric, ionization and thermal sensors OTHER SYSTEM FEATURES: Remote test feature from the panel Walk test with address display Low standby current OPTIONS: Remote LED output connection to optional RA100Z remote LED annunciator Installation FST-951 Series plug-in intelligent thermal detectors use a detach- able base to simplify installation, service and maintenance. Installa- tion instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5' (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring only. When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and iso- lator bases. Applications Use thermal detectors for protection of property. For further informa- tion, refer to 156-6522, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. Construction These detectors are constructed of fire-resistant plastic. The FST- 951 Series plug-in intelligent thermal detectors are designed to com- mercial standards and offer an attractive appearance. Operation Each FST-951 Series detector uses one of the panel's addresses (total limit is panel dependent) on the NOTIFIER Signaling Line Cir- cuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The FST-951 Series offers fea- tures and performance that represent the latest in thermal detector technology. DN-60975:B '6/26/2019 - Page 1 of 3 Product Line Information NOTE: "-IV" suffix indicates CLIP and FlashScandevice. FST-951: White, low-profile intelligent 135°F fixed thermal sensor, FlashScan only FST-951A: Same as FST-951 but with ULC listing FST-951-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, FlashScan and CLIP FST-951A-IV: Same as FST-951-IV but with ULC listing FST-951R: White, low-profile intelligent rate-of-rise thermal sensor, FlashScan only FST-951 RA: Same as FST-951 but with ULC listing FST-951R-IV: Ivory, low-profile intelligent rate-of-rise fixed thermal sensor, FlashScan and CLIP FST-951RA-11V: Same as FST-951R-lV but with ULC listing FST-951H: White, low-profile intelligent 190°F fixed thermal sensor, FlashScan only FST-951 HA: Same as FST-951 H but with ULC listing FST-951H-IV: Ivory, low-profile intelligent 190°F thermal sensor, FlashScan and CLIP FST-951 HA-IV Same as FST-951 but with ULC listing INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300A-6: Same as B300-6, ULC listed B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501-WHITE contains 10 B224RB-WH: White, relay base (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B224B1-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224B1-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B224B1A-WH: White, isolator detector base, ULC listing B224B1A-IV: Ivory isolator detector base, ULC listing B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200SA-WH: Same as B200S-WH, ULC listing B200SA-IV: Same as B200S-IV, ULC listing Page 2 of 3— DN-60975:13 '6/26/2019 B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base TR300-IV: Ivory, replacement flange for B21OLP(A) base RAIOOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300-6(A). M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: Color Kit (includes cover and trim ring), white, 10-pack CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing I B200SR-LF-WH: White, Low Frequency Intelligent, programmable - sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) iso ooi - I S I 01 Lb ENINHING I MMIfAC11l OIJAIITY SYSTEMS This document is not intended to be used for installation purposes. We by to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIER FloshScan® and NOTIFIERA are registered trademarks of Honeywell 12 Clintonville Road International, Inc. Northford, CT 06472 02019 by Honeywell International Inc. All rights reserved. Unauthorized 203.484.7161 use of this document is strictly prohibited. www.notifier.com Country of Origin: Mexico I 1 I NOTIFIER® by Honeywell SPECIFICATIONS Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC is 0.5% to 3.5% Size: 2.0" (5.3 cm) high; base determines diameter - B300-6: 6.1" (15.6 cm) diameter - B501: 4" (10.2 cm) diameter For a complete list of defector bases see DN-60981 Shipping weight: 3.4 oz. (95 g) Operating temperature range: FST-951, FST-951 R Series: —4°F to 100°F (-20°C to 38°C) FST-951H Series: —4°F to 150°F (-20°C to 66°C) Detector spacing: UL approved for 50 ft. (15.24 m) center-to-cen- ter, FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing Relative humidity: 10% - 93% non-condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) Mounting: B300-6(A) flanged base, included See "Product Line Information: Intelligent Bases," if using a dif- ferent base. ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC ("ON") Listings and Approvals Listings and approvals below apply to the FST-951 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULIULC Listing: S747 ° FM Approved CSFM: 7270-0028:0502 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:0502 Page 1 of I CATEGORY: 7270 -- HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneyweIl.com DESIGN: Models FST-951, FST-951 H, NH-200, NH-200H (fixed temperature) and FST-951 R, NH-200R (fixed temperature with Rate-of-Rise) electronic heat detectors. Suffix -IV for ivory color and -BL for black color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Models FST-951 and NH-200 (fixed temperature): 135°F. Models FST-951H and NH-200H (fixed temperature): 190°F. Models FST-951R, NH-200R (fixed temperature with rate of rise):135°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Notifier base B71OLP (CSFM No. 7300-0028:173); System Sensor bases B501, B2IOLP, B300-6, B300-6-IS (CSFM No. 7300-1653:0109); B224B1, B224RB (CSFM No. 7300-1653:0126); B200S, B200SR (CSFM No. 7300-1653:0213); B200S-LF, B200SR-LF (CSFM No. 7300-1653:238); and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev 02-14-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct JVI operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division NOTIFIER by Honeywell FSP-951 Series Addressable Photoelectric Smoke Detectors The NOTIFIER® FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the FSP-851 Series. A new modern, sleek, con- temporary design and enhanced optical sensing chamber is engi- neered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951T. The FSP-951R is a remote test capable detector for use with DNR Series duct detector housings. FSP-951 series detec- tors are available for both FlashScan® and CLIP applications as designated. Features SLC LOOP: Two-wire SLC loop connection Unit uses base for wiring Compatible with FlashScan® and CLIP protocol systems Stable communication technique with noise immunity ADDRESSING: Addressable by device Rotary, decimal addressing (Refer to the NOTIFIER panel manuals for device capacity.) ARCHITECTURE: Sleek, low-profile, stylish design Unique single-source design to respond quickly and dependably to a broad range of fires Integral communications and built-in device-type identification Built-in tamper resistant feature Remote test feature from the panel Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only) Built-in functional test switch activated by external magnet Removable cover and insect-resistant screen for simple field cleaning Expanded color options OPERATION: Designed to meet UL 268 7th Edition Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level LED "blinks" when the unit is polled (communicating with the fire panel) and latches in alarm. Low standby current MECHANICALS: Sealed against back pressure SEMS screws for wiring of the separate base Designed for direct-surface or electrical-box mounting Plugs into separate base for ease of installation and maintenance Separate base allows interchange of photoelectric, ionization and thermal sensors OPTIONS: Optional relay, isolator, and sounder bases Installation FSP-951 Series plug-in intelligent smoke detectors use a detach- able base to simplify installation, service and maintenance. Installa- tion instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring only. When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and iso- lator bases. Construction These detectors are constructed of fire-resistant plastic. The FSP- 951 Series plug-in intelligent smoke detectors are designed to com- mercial standards and offer an attractive appearance. Operation Each FSP-951 Series detector uses one of the panel's addresses (total limit is panel dependent) on the NOTIFIER Signaling Line Cir- cuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The FSP-951 Series offers fea- tures and performance that represent the latest in smoke detector technology. DN-60977:B • 7/1/2019 - Page 1 of 3 1 I I III Product Line Information NOTE: "-IV" suffix indicates CLIP and FlashScan device. FSP-951: White, low-profile intelligent photoelectric sensor, FlashS- can only FSP-951A: Same as FSP-951 but with ULC listing FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor FSP-951A-IV: Same as FSP-951-IV but with ULC listing FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device, FlashScan only FSP-9511A: Same as FSP-951T but with ULC listing FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed-temperature thermal device FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing FSP-951 R: White, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW, FlashScan only FSP-951RA: Same as FSP-951R but with ULC listing, for use with DNRA FSP-951 R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW FSP-951RA-IV: Same as FSP-951 R-IV but with ULC listing, for use with DNRA INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300A-6: Same as B300-6, ULC listed B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B200SA-IV: Same as B2005-IV, ULC listing B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base TR300-IV: Ivory, replacement flange for B21OLP(A) base RAIOOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300-6(A). M02-04-00: Test magnet B501-IV: Ivory color, 4" standard European flangeless mounting M02-09-00: Test magnet with telescoping handle base. UL/ULC listed (CSFM: 7300-1653:0109) CK300: Color Kit (includes cover and trim ring), white, 10-pack B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10 B224RB-WH: White, relay base (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B22481-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224B1-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B224B1A-WH: White, isolator detector base, ULC listing B224B1A-IV: Ivory isolator detector base, ULC listing B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200SA-WH: Same as B200S-WH, ULC listing Page 2 of 3— DN-60977:B 711/2019 CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack I I I I 1 SPECIFICATIONS Sensitivity: I . UL Applications: 0.5% to 4.0% per foot obscuration. ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter l - B300-6: 6.1" (15.6 cm) diameter - B501: 4" (10.2 cm) diameter For a complete list of detector bases see DN-60981 Shipping weight: 3.4 oz. (95 g) Operating temperature range: FSP-951: 32°F to 122°F (0°C to 50°C) FSP-951T Series: 32°F to 100°F(0°C to 38°C) . FSP-951R Series installed in a DNR/DNRW, -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ftimin. (1219.2 rn/mm.), suitable for installation in ducts Relative humidity: 10% - 93% non-condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC (ON") I DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors I 30 feet (9.1 m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is avail- able at www.systemsensor.com. I Listings and Approvals Listings and approvals below apply to the FSP-951 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listing: 51115 FM Approved CSFM: 7272-0028:0503 Iso 9001 l ElIElNC & MANUFltThRIN QUAlITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product Information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. l All specificahans are subject to change without nodce. N OTI F I ER FlashScan® NOTIFIERS, and System Sensor® are registered trademarks 12 Clintonville Road of Honeywell International, Inc. I Northford, CT 06472 52019 by Honeywell International Inc. All rights reserved. Unauthorized 203.484.7161 use of this document is strictly prohibited. www.notifier.com Country of Origin: Mexico I 10 NOTIFIER® by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0503 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models FSP-951, FSP-951R, FSP-9511, FSP-951T-ISO, NP-200, NP-200R, and NP-2001 analog addressable, photoelectric smoke detectors for open area and duct installations. Models FSP-951T, FSP-951T-ISO and NP-200T have complementary heat detectors. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed bases: *Model B7IOLP (CSFM No. 7300-0028:0173); System Sensor Models *B224Bl, *B224RB (CSFM No. 7300-1653:0126); B200S, B200SR (CSFM No. 7300-1653:0213); B200S-LF, B200SR-LF (CSFM No. 7300-1653:0238); *13501 *B2IOLP B300-6, B300-6-IS (CSFM No. 7300-1653:0109). System Sensor duct detector housings Models DNR and DNRW (CSFM No. 3240-1653:0209) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. *Revision 12/16/19 DCC ri This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division i1 NOTIFIER® by Honeywell DNR(A) and DNRW Intelligent Photoelectric Duct Detectors The Notifier DNR(A) intelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectan- gular footprints capable of mounting to a round or rectangular duct. The DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against fall- ing dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, oper- ating in airflow speeds of 100 to 4,000 feet per minute (0.5 - 20.32 m/s), temperatures of -4°F - 158°F (-20°C - 70°C), anda humidity range of 0 - 95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indicates a trouble sig- nal for a removed or improperly installed sensor cover. The housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module. The Notifier DNR(A) duct smoke detectors can be customized to meet local codes and specifications without additional wiring and are compatible with all previous models, including remote test accesso- ries. I Features Photoelectric, integrated low-flow technology Air velocity rating from 100 ft/min —4,000 ft/mm (0.5 m/s - 20.32 m/s) Versatile mounting options: square or rectangular. configuration Broad ranges for operating temperature (-4°F - 158°F, -20°C - 70°C) and humidity (0% - 95% non-condensirg) Patented sampling tube installs from front or back of the detector with no tools required Cover tamper signal Increased wiring space with a newly added 3/4" conduit knockout ° Available space within housing to accommodate mounting of a relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection Remote testing capability ° Requires com line power only Accommodates an addressable relay module, sold separately, (FIRM-1) for applications requiring a Form-C relay Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Operating Temperature Range: -4°F - 158°F (-20°C - 70°C) Storage Temperature Range: -22°F - 158°F (-30°C - 70°C) Operating Humidity Range: 0% - 95% relative humidity (non-con- densing) Air Duct Velocity: 100— 4,000 ft/mm (0.5— 20.32 m/s) Accessories Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. DNR(W) housings with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote-test-capable detector. ACCESSORY CURRENT LOADS AT 24 VDC Device Standby Alarm RA100Z OmA 12mA Max RTS151/RTSI51KEY 0mA 12mA Max Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest list- ing status. UL: S635, S3705 ULC: S635 CSFM: 3240-1653:0209 FM approved Product Line Information NOTE: °A suffix indicates ULC listed mode!. DNR(A): Intelligent non-relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). NEMA-4 rated. FSP-951 R(A)-IV: Remote test capable addressable low-profile pho- toelectric smoke detector; ivory; supports CLIP and FlashScan® protocols FSP-951R(A): Remote test capable addressable low-profile photo- electric smoke detector; white; supports FlashScan protocol only FSP-951(A)-IV: Addressable low-profile photoelectric smoke detec- tor; ivory; supports CLIP and FlashScan protocols FSP-951R(A): Addressable low-profile photoelectric smoke detec- tor; white; supports FlashScan protocol only DCOIL: Remote test coil. Required for older DNR(W) duct detector housing DUCTCOV: Retrofit DNR cover for manufactured prior to April 2014 I II I I I DN-60429:C2•11/7/2019— Page lof2 DUCTCOVW: Retrofit DNRW cover for manufactured prior to April 2014 DSTI(A): Metal sampling tube duct width up to 1 ft (0.3m) DSTI.5(A): Metal sampling tube duct widths up to 1 ft - 2 ft (0.3 - 0.6m) DST3(A): Metal sampling tube duct widths up to 2 ft —4 ft (0.6 - 1.2 M) DST5(A): Metal sampling tube duct widths up to 4 ft - 8 ft (1.2 - 2.4 M) DSTIO(A): Metal sampling tube duct widths up to 8 ft - 12 ft (2.4 - 3.7 m) DH4000E-1: Weatherproof enclosure ETX: Metal exhaust tube duct, width 1 ft (0.3 m) M02-04-00: Test magnet P48-21-00: End cap for metal sampling tubes RAIOOZ(A): Remote annunciator alarm LED RTS151 (A): Remote test station RTSI5IKEY(A): Remote test station with key lock Important Notes DNR(W) duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. DNR(W) duct detector housings with a date code of 0012 or ear- lier require a DCOIL and auxiliary 24 VDC power for remote test applications. Iso 9001 irtiir & MP!t&Mt1UU QUAlItY SYSTIMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIER 12 Clintonville Road NotifierT and FlashScanth are a registered trademark of Honeywell Inter- national Inc. Northford, CT 06472 2O19 by Honeywell International Inc. All rights reserved. Unauthorized 203.484.7161 use of this document is strictly prohibited. www.notifier.com Country of Origin: Mexico I NOTIFIER® by Honeywell I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-1653:0209 Page 1 of I CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. 1 I I I I 01-02-18 gt i.i .° This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division 7 I I I 6300-6 Standard B200SWH 6" Base (White) Sounder Base (White) 13501WHlTE Flangeless B501-BL Flangeless 4' Base (White) 4" Base (Black) NOTIFIER® by Honeywell Intelligent Bases Standard, Relay, Isolator, Sounder, and Low-Frequency Sounder Bases I I General To meet local code and application requirements, NOTIFIER® offers standard 4" and 6" bases, as well as, specialty base designs includ- ing relay, isolator, sounder and low frequency sounder options for the new 900 Series of addressable detectors as well as previous generations. The standard 4" and 6" bases offer a plug-in detector base intended for use in intelligent systems, with screw terminals identified with a (+ and -). The 4" base offers a compact design while the 6" base provides compatibility with a wider range of junction boxes. The specialty bases support application driven requirements. These bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface-mount boxes. The mounting plate enables pre-wiring of all connections to speed and simplify installation. Relay bases provide one form-C contact relay for control of auxiliary functions, such as door closure and elevator recall. The relay can operate in two different modes (short and long delay). The activation time for the short delay is 60-100 milliseconds, while the activation time for the long delay is 6-10 seconds. A shunt with pin headers, located on the base PC board, is used to set the delay timing. Isolator bases allow the Signaling Line Circuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled. The base isolates the section of the loop containing the short circuit from the remain- der of the circuit and automatically restores when the fault is cor- rected. Sounder and low frequency sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibil- ity in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent. Studies show that a lower frequency, cen- tered around 520 Hz, is the most ideal to wake sleeping occupants, even those with mild to severe hearing loss. The B200SR sounder and -LF sounder bases (B200SR-WH/ B200SR-1V1B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing BSOIBH Series sounder base installations. The device enables users to select one of two B501-supported tones (ANSI Temporal 3 or Continuous) through a jumper. The B200S sounder and -LF sounder bases (B200S-WH/B200S-IV/ B200S-LF-WH/B200S-LF-IV) adopt the same address as the detec- tor, but use a unique device type on the loop. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder - or a group of sounders - to activate. The command set from the FACP can be tailored to multiple event-driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, ANSI Temporal 4, or March Time) and group. In addition, some FACPs will enable custom tone patterns. The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables them to be used as a component of the general evacuation signal - along with other System Sensor AV appliances - when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. Specifications NOTE: Specifications applies to all model variants "A", "-BL", "-LF", "-lV" -WH, -WHITE. See Product Line Information for detailed model descrip- tion. Diameter B501-WHITE: 4" (10.16 cm) diameter. B300-6: 6.1" (15.49 cm) diameter. B224B1, B224RB: 6.2" (15.748 cm) diameter. B200S, B200SR, B200SCOA: 6.875" (17.46 cm) diameter. Wire gauge: 13224131, B224RB: 14 to 24 AWG. B300-6, B21OLP, B501, 13200S, B200SR, B200SCOA: 12 to 24 AWG Temperature range: B224B1, B224RB, B200S, B200SR, B200SCOA: 32°F to 120°F (0°C to 49°C). B300-6, B21OLP, B501: -4°F to 150°F (-20°C to 66°C). Humidity range: 10% to 93% RH, non-condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (non-condensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tem- perature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). DN-60054:K•7118/2018—Page 1of3 Electrical Ratings FOR B300-6 SERIES BASES: Operating voltage: 15 to 32 VDC Standby current: 170 pA maximum FOR B501 SERIES BASES: Operating voltage: 15 to 32 VDC Standby current: 150 pA maximum FOR B200 SERIES BASES: External supply voltage: 16 to 33 VDC (FWR) Standby current: 500 pA maximum. Alarm current: B200S(A)(-IV)(-WH) - 35 mA maximum at high-volume setting - 15 mA maximum at low-volume setting B200S-LF(-IV)(-WH) High-volume setting: —70 mA maximum @ 33.0 VDC —90 mA maximum @ 24.0 VDC —140 mA maximum @16.0 VDC B200S-LF(-IV)(-WH) Low-volume setting: - 15 mA maximum @ 33.0 VDC —20 mA maximum @ 24.0 VDC —25 mA maximum @ 16.0 VDC B200SR(A)(-IV)(-WH) - 35 mA maximum B200SR-LF(-IV)(-WH) —65 mA maximum @ 33.0 VDC —90 mA maximum @ 24.0 VDC - 125 mA maximum @16.0 VDC B200SCOA(-IV)(-WH) - 40mA Max (DC) - 70mA Max (FWR) SLC operating voltage: 15 to 32 VDC SLC standby current: See applicable sensor specification Sound output: B200S(A)(-LF)(-IV)(-WH), highvolume*: Greater than 85 dBA minimum. B200S(A)(-LF)(-IV)(-WH), lowvolume*: Greater than 75 dBA minimum. B200SR(A)(LF)(lV)(WH)*: Greater than 85 dBA minimum. B200SCOA(-IV)(-WH), highvolume**: Greater than 87 dBA mini- mum. B200SCOA(-IV)(-WH), lowvolume**: Greater than 85 dBA mini- mum *Measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) **Measured in a ULC anechoic room at 10 feet, 24 Volts continuous tone) FOR B22481, 8224RB (A) (-IV) (-WH): Operating voltage: 15 to 32 VDC (powered by SLC) Standby ratings: <450 pA maximum @ 24 VDC Set time (B224RB(A)(-IV)(-WH) only): short delay 60-100 millisec- onds; long delay 6-10 seconds Reset time (B224RB(A)(-IV)(-WH) only): 20 milliseconds maximum Relay characteristics (B224RB(A)(-IV)(.1NH) only): two-coil latch- ing relay; one Form-C contact; ratings (UL/CSA): 0.9 A @ 125 VAC, 0.9A @ 110 VDC, and 3.0 A @ 30 VDC Product Line Information INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed mode!. NOTE: "-IV" suffix indicates Ivory color model. NOTE: '-BL" suffix indicates Black color mode!. NOTE: "-WH" and "-WHITE" suffix indicates White color model. B2IOLP: Flanged mounted base. B2IOLPA: Same as B21OLP; ULC listed. B2IOLPBP: Bulk pack of B2IOLP, contains 10. 13300-6: White, 6" base, standard flanged low-profile mounting base. B300A-6: Same as B300-6, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10;. B300-6-IV: lvory,6" base, standard flanged low-profile mounting base. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed. B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. B501-IV: Ivory color, 4" standard European flangeless mounting base. UUULC listed. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listed. B224RBA-IV: Ivory, relay base, ULC listed. B224B1-WH: White, isolator detector base. B224B1-IV: Ivory isolator detector base. B224B1A-WH: White, isolator detector base, ULC listed. B224B1A-IV: Ivory isolator detector base, ULC listed. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan® protocol. B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan® protocol. B200SA-WH: Same as B200S-WH, ULC listed. B200SA-IV: Same as B200S-IV, ULC listed. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA.IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520. Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200S-LF4V: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Page 2 of 3— DN-60054:K .7/18/2018 B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH, ULC listed. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listed. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A), B300(A)-6 bases. TR300-IV: Ivory, replacement flange for B21OLP(A), B300(A)-6-IV bases. RAIOOZ(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: White, detector color kit. Pack of 10. CK300-IR: White, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. CK300-IV: Ivory, detector color kit. Pack of 10. CK300-IR-IV: Ivory, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. CK300-BL: Black, detector color kit. Pack of 10. CK300-IR-BL: Black, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL/ULC Listed: S1115 FM Approved CSFM: 7300-1653:0109, 7300-1653:0126, 7300-1653:0213, 7300-1653:0236 Junction Box Selection Guide Base Models Single Gang Double Gang 3.5' Oct. 4.0" Oct. 4.0" Sq. 4.0" Sq. with 3.0" 50 mm 60 m m 70 mm 75 mm mud ring B200S, B200SR, B200SCOA Yes Yes Yes Yes Yes Yes No No No No B501 No No Yes No No Yes Yes Yes Yes No B21OLP, B300-6 Yes No Yes Yes Yes Yes No No No No B224B1, B224RB Yes Yes Yes Yes Yes Yes No No No No NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. NOTE: Applies to all model variants "A", "-BL'ç "-LF", "-IV", "-WH" and 'WHITE" See Product Line Information for detailed model description. Iso 9001 a i - • EMIF*EIIr I MmIF11It QUAlITY SYSTEMS This document is not intended to be used for installation purposes. We hy to keep our product information up-todate and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIER FlashScan®, NOTIFIER® and System Sensor® are regis- 12 Clintonville Road tered trademarks of Honeywell International Inc. Northford,CT 06472 ©2018 by Honeywell International Inc. All rights reserved. 203.484.7161 Unauthorized use of this document is stdcfly prohibited. www.notifier.com Country of Origin: Mexico I NOTIFIER® I by Honeywell I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models B401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B402B, B404B, B404BT, B406B, B501, B50IB, 14506587-002, 1350I13H, B50IBHT, B40IBH, BIIOLP, B110RLP, BIIORLP750, B112LP, BII4LP, BII4LPBT, BII6LP, B2IOLP, B501-BL, B501-IV, *135011 -WHITE, 8300-6, B300-6-IV, B300-6-IS detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, *model number, *electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. *Refer to Manufacturers Installation Instruction Manual for details. NOTE: Formerly 7300-1209:128 I I 1 I I Rev 04-03-18 gt ØTI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftV% operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division I I I DN-6726:D • H-240 NOTIFIER by Honeywell E Intel Ii D neral NBG.1 2LX Addressable Manual Pull Station The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG121R). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-12LX stations per loop on CLIP protocol loops. Up to 159 NBG-1 2LX stations per loop on FlashScan® pro- tocol loops. Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location The NBG-12LX Addressable Manual Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. It the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 on FlashScan® systems, 1 —99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-i 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or DN-6726:D • 4/13/2012 - Page 1 of 2 I 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command I from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of I the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information I NBG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) I NBG-12LX5P: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. I SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. I NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be I listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. ULJULC Listed: S692 (listed for Canadian and non-Cana- than applications). MEA: 67-02-E. CSFM: 7150-0028:0199. FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). I . BSMI:C1313066760047. U.S. Coast Guard. Lloyd's Register. I . FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. I NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. Iso ooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice QUALITYSYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6726:D • 4/13/2012 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:0199 Page 1 of I CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models NBG-12, NBG-12S, NBG-I2LR, NBG-I2LRA, NBG-12LAO, NBG-I2LAOB, NBG-12-LO, NBG-I2LOB, NBG-12W, NBG-I2LW, NBG-I2NC, NBG-12WP, NBG-12LWP, NBG-12L, NBG-12LX, NBG-I2LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBG-I2SP, NOT-BGI2LX, NBG-I2LXSP, NBG-I2LXBL and NBG-I2LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBG-1 2LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-1 2WP, NBG-1 2LW, NBG-1 2W, NBG-I2LWP, NBG-1 2LAO, NBG-1 2L0, NBG-1 2LAOB and NBG-1 2LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-1 0 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51b5. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct IIVI operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 ,Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division ( I! Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features I I I I I I I I I Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95,110,135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Strobes and Horn Strobes listed for wall mounting only Horns listed for wall or ceiling use Agency Listings GNAUNG USTED APPROVED S55l2 FM approved eacepr 7125-1653:0504 S401 1 for ALERT models 7135-1653:0503 3057383.3057072 The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS865-05 • 2/22/2018 • Page 1 I I I I [1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the SynceCircUitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts, 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal) or 16.5 to 33 V (24 V nominal) input Terminal Wire Gauge 12 to 18AWG Wall-Mount Dimensions (including lens) 5.6" L x 4.7"W x 1.91" D (143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" Lx 3.46' W x 1.91" D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6'L x 4.7"W x 1.25"D(143 mm Lx 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45" W x 1.25" D (133 mm Lx 88 mm W x 32 mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 Cd and 30 cd. AVDS865-05 • 2/22/2018 • Page 2 I UL Current Draw Data ___________ I 817.5VoIts 'i%—Molts 1 TAM 8-17.5Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 I 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 I 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 I Coded High 43 47 54 3.1 KHz Coded High 42 43 54 I - H 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd l5cd 30cd 75cd 95cd llOcd 135cd 185cd I Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High I 93 156 53 73 119 140 164 190 242 3.lKTemporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low I 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.lKTemporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must I be provided by the NAC. It the NAC voltage is held constant, the horn output remains constantly on. AV05865-05 • 2/22/2018 • Page 3 I L-Series Dimensions 32 mm up C3 133.9 mm LL"J A0548-0O A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL 4.70 —a (11.94 cm) 1.91" (4.85 cm) 1.25" (3.18 mm) 5.67" .2W. (144 cm) L Strobe, Horn Strobe A0550-00 1.25" 32 mm A0549-00 Horn A0554-01 Wall Surface Mount Back Box SBBR IfS B B WL L-Series Ordering Information Wall Horn Strobes Horns* P2RL 2-Wire, Horn Strobe, Red HRL* Horn, Red P2WL 2-Wire, Horn Strobe, White HWL* Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL* Compact Horn, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White HGWL* Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain ' TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBRL Wall Surface Mount Back Box, Red P4RL 4-Wire, Horn Strobe, Red SBBWL Wall Surface Mount Back Box, White P4WL 4-Wire, Horn Strobe, White SBBGRL Compact Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box, White SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have 'FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. *Hornonly models are listed for wall or ceiling use. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2018 System Sensor. 4 IPhone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensar.corn for current product information, including the latest version at this data sheet. www.systemsensor.com AVDS865-05 "2/22/2018 I Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNAUNG LISTED APPROVED S5512 FM approved except 7125-1653:0504 S401 1 for ALERT models 7135-1653.0503 3057383 AVDS868-02 • 12/01/2017 • Page 3 L-Series Specifications - . . General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync'Circuit°° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync'Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/F\NR1 Operating Voltage Range2 . 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWO Ceiling-Mount Dimensions (including lens) 6.8' diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9 diameter x 3.4' high (1175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P. 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AV0S868-02 • 12101/2017 • Page 2 I UL Current Draw Data ____________________________________ I I 8-17:5 Volts 16-33 Volts 8-175 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR I Candela 15 Range 30 87 153 41 63 60 86 Temporal Temporal High Low 39 28 44 32 54 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 I . 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A . 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 I Coded High 43 47 54 3.1 KHz Coded High 42 43 54 I 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd llscd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 I Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High I 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 I 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input lscd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low I 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High I 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 Non-Temporal Low 79 101 150 171 196 229 260 I 3.1K Horn Strobe Tones and Sound Output Data I 8-17.5 16-33 I Switch . Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AV0S868-02 • 12/01/2017 • Page 3 2.47" (62.7 mm) 1.37'(34.8 mm) 6.83" dF (173n 6.92" di-- (1 75. k- 2.5" (64mm) L-Series Dimensions A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box -01 I01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information I Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". @2017 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject t without notice. Visit systernsensorcom tcrcurrent product information, of this data sheet. Phone: 800-SENSOR2 • Fax: 630-377-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: System Sensor Indoor 2-wire and *4..wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division I El I I I Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 01 Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ff.\ the test results and/or other data but does not make an independent verification of any claims. This listing is not 4 an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division I U CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WailTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 9t This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division I 1 I] I Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division STE SSM/SSV Series Alarm Bells System Sensor's SSM and SSV series alarm bells are low current, high decibel notification appliances for use in fire and burglary systems or other signaling applications. Features Approved for indoor and outdoor use Low current draw High dB output Available in six-inch, eight-inch, and ten-inch sizes AC and DC models DC models polarized for use with supervision circuitry Mount directly to standard four-inch square electrical box indoors SSM and SSV series come pre-wired Reliable Performance. The SSM and SSV series provide loud resonant tones. The SSM series operates on 24VDC and are motor driven, while the SSV series operates on 120VAC utilizing a vibrating mechanism. Simplified Installation. For indoor use, the SSM and SSV series mount to a standard four-inch square electrical box. For outdoor applications, weatherproof back box, model number WBB, is used. The SSM and SSV series come pre-wired, to reduce installation time. The SSM series incorporates a polarized electrical design for use with supervision circuitry. Agency Listings @ @ "j~> 0 LISTED APPROVED S4011 CS549 3005255 7135-1653:0125 I SSM/SSV Specifications Model shall be a SSM or SSV Series alarm bell. Bells shall have underdome strikers and operating mechanisms. Gongs on said bells shall be no smaller than nominal 678710"(specify size) with an operating voltage of 24VDC or 120VAC (specify by part number). Bells shall be suitable for surface or semi-flush mounting. Outdoor surface mounted installations shall be weatherproof (using optional WBB weatherproof electrical box). Otherwise bells shall mount to a standard 4-square electrical box having a maximum projection of 21/2. Bells shall be located as shown on the drawings or as determined by the Authority Having Jurisdiction. Bells shall be listed for indoor/outdoor use by Underwriters Laboratories and the California State Fire Marshal, and approved by Factory Mutual and MEA. Operating Temperature Range -31°F to 140°F Operating Voltage SSM series: 24 VDC SSV series: 120 VAC Termination Provided with 2 sets of leads for in/out wiring Service Use Fire Alarm, General Signaling, Burglar Alarm Warranty 3 years 1 Model Gong Diameter Nominal Voltage Operating Voltage Maximum Current Sound Output (dBA) (inches) Limit SSM24-6 6 Regulated 24VDC 16 to 33VDC DC-31 .1mN RNR-53.5mA 82 SSM24-8 8 Regulated 24VDC 16 to 33VDC DC-31.1mN FWR-53.5mA 80 SSM24-10 10 Regulated 24VDC 16 to 33VDC DC-31 .1 mA! FWR-53.5mA 81 SSV120-6 6 Regulated 120VAC 96 to 132VAC 53mA 85 SSV120-8 8 Regulated 120VAC 96 to 132VAC 53mA 82 SSV120-10 10 Regulated 120VAC 96 to 132VAC 53mA 82 * Sound output measured at Underwriter Laboratories, as specified in UL464 Ordering Information LLtJ l"I1iI I S5M24-6 55M24-6A Bell, 6' 24VDC, Polarized, 82dBA SSM24-8 SSM24-8A Bell, 8' 24VDC, Polarized, 80dBA SSM24-10 SSM24-1OA Bell, 10 24VDC, Polarized, 81dBA SSV 120-6 SSV 12O-6A Bell, 6 12OVAC, 85dBA SSV120-8 SSV120-8A Bell, 8, 12OVAC, 82dBA SSV120-10 55V120-10A Bell, 10' 120VAC, 82dBA WBB Weatherproof back box for SSM and SSV series, when installed outdoors 3825 Ohio Avenue • St. Charles, IL 60174 ©2012 system Sensor. SMSTEM for current product information, including the latest version of this data sheet. www.systemsensor.com WF0574501 • 3/12 1 $ Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without eotice. Visit systemsensor.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0217 Page 1 of I CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models SSM24-6, -8, -10 and SSVI20-6, -8, -10 audible signal devices. Models are AC or DC powered and available in 6", 8" and 10" bells. Refer to listee's data sheet for detailed product description and operational considerations.The units may be employed outdoors when used with NEMA 3R weather resistant back box Model WBB. RATING: SSM24-6 Sound output: 82 dBA SSM24-8 Sound output: 80 dBA SSM24-10 Sound output: 81 dBA SSVI20-6 Sound output: 85 dBA SSVI20-8 Sound output: 82 dBA SSVI20-10 Sound output: 82 dBA SSM Series Voltage Range: 16-33 VDC SSV Series Voltage Range: 96-132 VAC Temperature Range: -31°F to 150° F (-35°C to 66°C) INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. 07-30-10 fm TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the -test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CELLULAR ALARM TG=7FS COMMUNICATOR FOR 3G/4G NETWORKS TE LG UAR D COMMERCIAL FIRE PRODUCT FEATURES - Meets UL 864 requirements for sole, primary or backup path communications. I- Provides RMR protection by leveraging technology that operates on 3G/40 networks. I- Supports listen-in, two-way voice verification over cellular. - Minimizes false alarms by providing dual paths for self-tests. I- Falls back to 20 (GSM) if a 30/40 network isn't available. The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2010 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within five minutes of an outage, the TG-7FS can he installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS because of the new five minute supervision mode. LI The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. AN TE LG UAR D CELLULAR ALARM TG-7FS COMMUNICATOR FOR 3G/4G NETWORKS Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACID 12, ACID 35, ACID 50, ACID 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. UL Listings Commercial Fire 864 Control units & accessories for fire alarm systems Commercial Burglary 365 Police Station connected burglar alarm units and sy ste ins 1610 Central station burglar alarm units: Line security sorvcies Residential 985 Household fire warning systems - For the most current product specifications and UL Listings visit www.Teiquard.com. - //- C] CON SE 'UFITY IC I LISTED NFPA LII) I LUfl INTERNATIONAL Telguard, a Division of Telular Corporation 2727 Paces Ferry Road SE Suite 1-800 Atlanta, GA 30339 • USA 800-229-2326. Option 5 www.Telguard.com Copyright -2012 Telular Corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com DESIGN: Models TG7LAA02, TG7LA00I, TG7LAA0I, TG7LA002, TG7LAF0I, TG7LAF02, *TG7UBLA and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model TG7LAF01, TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 11-27-19 gt Ti This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division I TEl iSENSOR -;;;; SM I Duct Smoke I Detector Accessories I Expand the versatility of the lnnovairFlexTM line of duct e smoke detectors with System Sensor notification and test I accessories. * Li I Available Accessories Duct smoke detector accessories add functionality to the duct I APA151 Piezo Annunciator smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All MHR Mini-Horn, Red System Sensor duct smoke detectors and accessories are UL listed. MHW Mini-Horn, White The APAISI piezo annunciator, which replaces the APA451 with a RA100Z/RA100ZA Remote Annunciator new, improved look, provides an audible alarm signal, a red LED to RTS 151 Remote Test Station indicate alarm status, and a green LED to indicate power status. It is I RTS151KEY Remote Test Station with Key intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with RTS2 Multi-Signaling Accessory NFPA 90A. AOS Add-On Strobe The MHR and MHW SpectrAlert® Advance mini-horns feature RTS2-AOS Multi-Signaling Accessory temporal or continuous tones at high and tow volume settings. I applications Their small footprint allows mounting to single-gang back boxes for where a small device is desired. The RAIOOZ and RAIOOZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The Ill 5I and RTSI5I KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151 KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFIex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both Agency Listings by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS C E ( Add-On Strobe) is an optional accessory included with the RTS2- AOS model. 7300-1653:0212 LISTED APPROVED 7300-1653:0211 S2522 3034401 7135-1653:0196 9080301 EI RTS151 KEY UL S2522 SMOKE - . RTS2-AOS UL S2522 APA151 UL S4011 ri MHW UL S4011 MHR UL S4011 AOS Specifications, Duct Smoke Detector Accessories I .. Voltage Regulated 24 VDC Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Operating Voltage 16 to 33 VDC Total Current: 105 mA max. Maximum Alarm Current 30 mA Test Switch 10 VA @32 VDC Temperature Range 0°C to 49°C (32°F to 120°F) Reset Switch 10 VA @ 32 VDC Relative Humidity 10 to 93% non-condensing Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60°C (14°F to 140°F) Dimensions 4.6'H x 2.9W < .45"D Relative Humidity 95% non-condensing Wire Gauge 14to18AWG Voltage Regulated 12 DC or FWR (Full Wave Dimensions 4.8"H x 2.90"W x 1.4"D Rectified) or Regulated 24 VDC or FWR 1] Sounder Current Draw 22 mA RIMS max. at 8 to 17.5 Volts DC Power Requirements Power LED (Green): 14 to 35 VDC, 29 mA RIMS max. at 16 to 33 Volts DC 12 mA max. Temperature Range 0°C to 49°C (32°F to 120°F) Alarm LED (Red): 2.8 to 32 VDC, Humidity Range 10 to 93% non-condensing 12 mA max. Total Current: 105 mA max. Nominal Sounder 3 kHz Alarm Response Time 40 seconds max. Frequency Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60°C (14°F to 140°F) Dimensions 4.6"H x 2.9"W x 0.45D Relative Humidity 95% non-condensing Wire Gauge 14to18AWG Voltage Range Conventional System: 3.1 to 32 VDC Dimensions 4.6"H x 2.75"W x 1.8"D Intelligent System: 18 to 32 VDC -. I . Maximum Alarm Current 10 mA Voltage 20 to 29 VDC Dimensions 4.6 "H x 2.8"W x 1.3"D 'Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8"W x 5.3"H x 1.6"D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. DI RTS151 UL S4011 DI RA100Z UL S2522 3825 Ohio Avenue • St. Charles, IL 60174 e2013 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsenscccorn I for current product information, including the latest version of this data sheet, www.systemsensor.com HVDS20202 • 8/13 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models RTS1 51, RTSI 51 KEY and RA1 OOZ Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. I Fire Engineering Division Multi-Voltage Conventional Relays System Sensor's multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of system interfacing. Features Multi-voltage operation Activation LEDs Easy and flexible installation Reliable and robust design Multipurpose field installations Multi-voltage relays with terminal strip field wiring connections, mounting track, and hardware for R-1 OT/20T and R-1 4T/24T Removable front cover on steel enclosure for R-1 OUR-20E and R- 14/R-24E, which mount inside the enclosure LED viewing hole on top of the steel enclosure's cover Extra pair of wires for redundant power input on PR-3 Terminal strip field wiring connections, mounting track, and hardware The R-1 OT, R-20T, R-14T, and the R-24T models are multi- voltage relays with terminal strip field wiring connections, mounting track, and hardware. The R-1 OT is a single FORM-C (SPDT) relay with a red activation LED, and the R-14T is a four-gang 1 FORM-C (SPDT) relay with four red activation LEDs. The R-20T is a single 2 FORM-C (DPDT) relay with a red activation LED, and the R-24T is a four-gang 2 FORM-C (DPDT) relay with four red activation LEDs. The R-1OE/R-20E and R-14E/R-24E are similar to the T-series track mount relays, but they are mounted into a steel enclosure. The enclosure has a removable front cover that provides easy access and an LED viewing hole on the top of the cover. PR-i IPR-2IPR-3 are epoxy encapsulated multi-voltage relays. They are single-pole double-throw relays that use a red LED as a visible indication of relay coil energization. PR-3 is identical to PR-2, except it has an extra pair of wires for redundant power input. Model EOLR-1 is an epoxy encapsulated, single-pole single-throw, normally open relay that can be used as an end of line device in fire alarm systems, e.g. to supervise power supplies. Agency Listings MEA vi approved LISTED Multi-Voltage Conventional Relay Specifications JEW Operating Voltage 18- 35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Voltage 18-35 VDC, 18-35 VAC, 120 VAC Operating Current 20 mA DC max. @24 VDC, 24 VAC, 115 VAC, Operating Current 15 mA DC max. @24 VDC, 24 VAC, 120 VAC 230 VAC (R1 OT/R14T) Operating Temperature -40°F to 158°F (-40°C to 70°C) 40 mA DC max. @24 VDC, 24 VAC, 115 VAC, Humidity Range 10- 93% RH 230 VAC (R-20T/R-24T) Wire Length 8-minimum Operating Temperature -40°F to 158°F (-40°C to 70°C) Dimensions 0.87-H x 2.01 V x 1.4211 Humidity Range 10% - 93% non-condensing - ,,.. - Dimensions R-1OT/R-201: 2.51x 3.35Wx 1.21-I R-14T/R-24T: 101x3.35Wx 1.21-I Contact Ratings 24 VDC: 7Awith L/R=5 mS 120 VAC: 10A 120 VAC: 1/6 HP 230 VAC: 7 A Operating Voltage 18-35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @24 VDC, 24 VAC, 115 VAC, 230 VAC (R-i OUR-14E) 40 mA DC max. @24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20E/R-24E) Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10% - 93% non-condensing Dimensions R-1 OUR-20E: 5.11 x 3.75W x 2.51-I R-14E/R-24E: 11 lx 5.3vV x 2.51-I Contact Ratings 24 VDC: 7 A with LJR = 5 mS 120 VAC: 10A 120 VAC: 1/6 HP 230 VAC: 7 A Contact Ratings ...... 4 vL)L: / / with [J = 5 m 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A resistive 30 VDC: 10 A resistive Operating Voltage 10 to 40 VDC Operating Current 30 mA DC max. Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10- 93% RH Wire Length 8-minimum Dimensions 0.91'Hx 1.65Wx 1.2211 Contact Ratings 120 VAC: 10 A max. (resistive load) 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load) 30 VDC: 10 A max. (resistive load) l•_• ,. .. .1 Operating Voltage 9 to 40 VDC Operating Current 20 mA DC max. Operating Temperature -22°F to 140°F (-30°C to 60°C) Humidity Range 10- 93% RH Wire Length 8-minimum Contact Ratings 120 VAC: 0.5 A max. (resistive load) 30 VDC: 3 A max. (resistive load) PR-i E01-R-1 PR-3 R-1OE & R-20E Enclosure PR-2 R-10T R-14T R-14E & R-24E Enclosure 02 7 System Sensor, 3825 Ohio Avenue. St. Charles, IL 60174 current product information, in ludingthel test version ofthis data sheet. SEN. SOR Phone: 800-SENSOR2. Fax: 630-377-6495 A05~037C2-005-3/07' #1782 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 00 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0172 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models PR-I, -2, -3 Multi-Voltage Relay. Refer to listee's data sheet for detailed product description and operational considerations. RATING: PR-11 = 24 VDC/ (+); 24 VAC; 120 VAC, 60 Hz PR-2, -3 = 10 -40 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1209:232 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division DN-60897-C • G-156 I PRN.7 Printer NOTIFIER® by Honeywell I General I I The PRN-7 printer is used with Notifier fire alarm control panels (FACP5) with printer capability to provide a written record of sys- tem events and status changes. In NOTI.FIRE.NETTM applica- tions, PRN-7 can be used with the NCA-2, NCA, Onyxworks. Features Provides a hard copy printout of all system events and status changes. Time stamps printed on the record of each event and status change with the current time-of-day and date. Uses standard 9" x 11" tractor-feed fan-fold paper. Provides 80 columns of data at 10 characters per inch. Provides printed records of system configuration and addressable device parameters. 24-pin print head. Very quiet (approximately 52 dBA). Applications Printed transaction records reduce the man-hours required to install and maintain a system. A printed record of all system events (alarms, troubles, etc.) and status changes can be espe- cially valuable in the event of a disputed incident. Construction and Operation The printer is housed in its own separate enclosure and is suit- able for placement on a desk top, counter, or table. Installation The PRN-7 should be placed in a secure area to prevent theft of the printer and/or printed records. The PRN-7 must not be located further than 20 ft/6.10 m (actual cable length) from the control panel. Consult the control panel installation manual for the proper method and PIN numbers used to complete the electrical con- nection to the control panel. NOTE: If printer operation is required during failure of primary power, use of a separate UL-listed Uninterruptable Power Supply (UPS) system is recommended. Printer Specifications Printer Method Serial printing with 24-pin matrix print head. Printing Speed (copy draft) 333 cps at 10 cpi. Character Density 10 cpi standard (12, 15, 17.1, and 20 cpi available via front panel). Graphic Resolution (VxH) Up to 360 x 360 dpi. Ribbon Life (approx.) 6 million characters (DPQ). Acoustic Noise Level 52 dBA (approx.). Dimensionsl8"(45.8cm)W x 7.9" (20.01 cm)H x 10.4 (27.8cm)D. Weight 18.9 pounds (8.6 kg). Power Supply 110-230 VAC auto ranging, auto sensing. Power Consumption 40 watts (printing). Operating Environment Temperature 50°F to 104°F (10°C to 40°C). Operating Environment Humidity 10% to 85% (non-condens- ing). Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S35611 ULC Listed: E351188 CSFM Listing: 7305-0028:0501 FDNY: COA# 6206, 6211, 6212 Product Line Information PRN-7: 24-pin dot-matrix printer, 110-230 VAC power. I I DN-60897-C ° 9/27/17 - Page 1 of 2 I NOTI.FIRE.NETTM is a trademark, and NOTIFIER® is a registered trademark of Honeywell International Inc. ©2017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 000i We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Country of Origin: USA For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60897-C • 9/27/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7305-0028:0501 Page 1 of I CATEGORY: 7305 -- MISCELLANEOUS SIGNALING EQUIPMENT LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Model PRN-7 printer. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 100-240 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a printer for use with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7305-2200:0100 I I I I I I I 09-05-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12 x 13' tall and 2'hdeep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high Fire Alarm Documents Legend sheet for passwords and system information FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2010 section 6,2.2.1 states, A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SIB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold Important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system Information. 1509001 REGISTERED COMPANY ADA NFFX Made In, U.S.A. 4/ Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.0 112 Space Age Electronics, Inc. www.lsae.com 800.4.86.1723 Toll Free 508.485.0966 Local 508.48.5.4740 Fax No Excuses. Just Solutions! LFSPACE AGE L ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be constructed of 18 gauge cold rolled steel,. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1' high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 112 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system Information. The FAD will have securely mounted Inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. D USB Storage Interface Requires Standard USB-B Connector Ps om.tn C.I%n d*j 9,se.fl1 c3wr Mr* IsIWW OoI,*flIW dana.pl3.a.ac. .10 1...,._. . I---- ••'t=• --'.- - nfl U t.!Q.Q.a. *Ct. 1tIMfl *.,111 fl,a tTfls*4 %s I Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (lAME FAD) This document is subject to change without notice, see doc D0479 for legal disclaimer E00549 LT10559 Rev.0 212 Space Age Electronics. Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions!