Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2501 EL CAMINO REAL; 100; AS140116; Permit
City of Carlsbad Sprinkler Permit Permit No: AS140116 2501 EL CAM INO Job Address: Status: PENDING REAL Permit Type: SPRINK Applied 5/9/2014 Parcel No: 1563020800 Approved: Lot #: 0 Reference No.: Issued: PC #: Inspector: Project Title: 24 HOUR FITNESS INSTALL NEW SPRINKLER SYSTEM IN NEW GORE & SHELL. UNDGD PERMIT ON THESE PLANS IS PERMITTED SEPARATELY. Applicant: WESTERN STATES FIRE PROTECTION 3720 INDUSTRY AV STE 107 LAKEWOOD 562-279-0770 Owner: CMFPCRLLC C/O WESTFIELD PROPERTY TAX DEPT P0 BOX 130940 DEPT WFLD CARLSBAD, CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 1,379 0 1,379 1,379 1' 3i Ljf (0 Western States Fire Protection Co. FILE c CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR i Western States 110 Fire Protection Co. .eeceia 4eu dm1 3820 Oceanic Drive, # 309 . Oceanside, CA 92056 P (760) 439-7558 • F (760) 439-7655 Lic. C16-488359 A BOVEGROUND PIPING PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall b corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understoot the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approvin authority's requirements or local ordinances. PROPERTY NAME: I Date: WESTFIELD - CORE AREA . 10/14/2014 PROPERTY ADDRESS: 2501 EL CAMINO REAL, CARLSBAD, CA 92008 ACCEPTED BY APPROVING AUTHORITY(S) NAMES: CARLSBAD FIRE DEPARTMENT 1638 FARADAY AVENUE AHJ ADDRESS CARLSBAD, CA 92008 INSTALLATION CONFORMS TO ACCEPTED PLANS Z YES 0 NO EQUIPMENT USED IS APPROVED 0 YES 0 NO PLANS IF NO, EXPLAIN DEVIATIONS: HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION YES fl NO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPLAIN: INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: SYSTEM COMPONENTS INSTRUCTIONS 0 YES 0 NO CARE AND MAINTENANCE INSTRUCTIONS 0 YES 0 NO NFPA25 Z YES 0 NO LOCATION SUPPLIES OF SYSTEM BUILDING: MAKE MODEL YEAR OF K SIN QUANTITY TEMPERATURE MANUFACTURE FACTOR RATING Reliable F1FR Recessed 2013 5.6 RA1414 20 155° F Reliable F1FR Upright 2013 5.6 RA1425 608 155° F SPRINKLERS PIPE AND TYPE OF PIPE: Schedule 10 (MAINS) and Schedule 40 (BRANCHLINES) FITTINGS TYPE OF FITTINGS: Firelock Grooved (MAINS) and Malleable iron Class 150 (BRANCHLINES) ALARM DEVICE I I MAXIMUM TIME TO OPERATE THRU TEST CONNECTION ALARM VALVE TYPE MAKE I MODEL I MIN. I SEC. OR FLOW INDICATOR Water Flow Switch Potter Electric VSR-F I 30 I 60 I I DRY VALVE . I Q.O.D. MAKE MODEL SERIAL NO. MAKE . MODEL SERIAL NO. TIME TO TRIP TRIP POINT AIR TIME WATER ALARM THRU TEST WATER PRESSURE AIR PRESSURE PRESSURE REACHED OPERATED CONNECTION* TEST OUTLET* PROPERLY DRY PIPE MIN. SEC. PSI PSI PSI MIN. I SEC. YES NO OPERATING . I TEST Without 0 0 Q.O.D. I With I o o IF NO, EXPLAIN: *MEASURED FROM TIME INSPECTOR'S TEST CONNECTION OPENED. (OVER Western States Fire Protection Co. Western States I Fire Protection Co. 3820 Oceanic Drive, #309 Oceanside, CA 92056 P (760) 439-7558 F (760) 439-7655 Lic. C16-488359 OPERATION: 0 PNEUMATIC 0 ELECTRIC 0 HYDRAULIC PIPING SUPERVISED: El YES U NO I DETECTING MEDIA SUPERVISED: 0 YES 0 NO DOES VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL STATIONS: U YES U NO DELUGE & IS THERE AN ACCESSIBLE FACILITY IN 0 YES IF NO, PREACTION EACH CIRCUIT FOR TESTING: U NO EXPLAIN: VALVES DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT OPERATE MAXIMUM TIME TO MAKE MODEL SUPERVISION LOSS ALARM? A VALVE RELEASE? OPERATE RELEASE YES NO YES NO MIN. SEC. El 1 0 0 0 Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above static pressure in excess of 150 HYDROSTATIC: psi (10.2 bars) for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. All aboveground piping TEST leakage shall be stopped. DESCRIPTION PNEUMATIC (2.7 bars) ai Establish 40 psi r pressure and measure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2.00 IF NO DRY PIPING PNEUMATICALLY TESTED: 0 YES El NO STATE EQUIPMENT OPERATES PROPERLY: 0 YES El NO REASON: DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR 0 YES 0 NO TESTING SYSTEMS OR STOPPING LEAKS? TESTS DRAIN READING OF GAGE LOCATED NEAR WATER SUPPLY TEST RESIDUAL PRESSURE WITH VALVE IN TEST TEST CONNECTION: PSI CONNECTION OPEN WIDE PSI UNDERGROUND MAIN AND LEAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING: VERIFIED BY COPY OF THE U FORM NO. 85B YES 0 NO OTHER FLUSHED BY INSTALLER OF UNDER- YES 0 NO EXPLAIN GROUND SPRINKLER PIPING BLANK NUMBER NUMBER REMOVED TESTING USED LOCATIONS: GASKETS WELDED PIPING: YES 0 NO IF YES: DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS YES El NO OF AT LEAST AWS B2.1 ? WELDING DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE WITH THE YES U NO REQUIREMENTS OF AT LEAST AWS B2.1? DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND 0 YES U NO OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? CUTOUTS (DISCS) DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS (DISCS) ARE RETRIEVED? Z YES El NO HYDRAULIC DATA YE NO IF NO, NAME PLATE PROVIDED. S El NAMEPLATE EXPLAIN: REMARKS DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: NAME OF SPRINKLER CONTRACTOR: WESTERN STATES FIRE PROTECTION CO. TESTS WITNESSED BY OWNER (SIGNED) /( SIGNATURES 6fS).'c9NTRACTOR (SIGNED) TITLE DATE ---' '*' Jv10RSHAi(S1Gj. 1 TITLE D,Arg (_ ( ( ( FOR TITLE DATE ADDITIONAL EXPLANATION AND NOTES REMARKS 8496 F/v4) (Back) Western States Fire Protection Co. AbWestern States Fire Protection Co. -f49 4 4(d '4me 3820 Oceanic Drive, #309 . Oceanside, CA 92056 P (760) 439-7558 • F (760) 439-7655 Lie. C16-488359 CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR A BOVEGROUND PIPING PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall L corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understoc the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approvir authority's requirements or local ordinances. PROPERTY NAME: I Date: WESTFIELD - REGAL EAST 10/14/2014 PROPERTY ADDRESS: 2501 EL CAMINO REAL, CARLSBAD, CA 92008 ACCEPTED BY APPROVING AUTHORITY(S) NAMES: CARLSBAD FIRE DEPARTMENT 1638 FARADAY AVENUE AHJ ADDRESS CARLSBAD, CA 92008 INSTALLATION CONFORMS TO ACCEPTED PLANS YES fl NO EQUIPMENT USED IS APPROVED 9 YES 0 NO PLANS IF NO, EXPLAIN DEVIATIONS: HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION YES 0 NO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPLAIN: INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: SYSTEM COMPONENTS INSTRUCTIONS 0 YES 0 NO CARE AND MAINTENANCE INSTRUCTIONS Z YES 0 NO NFPA2S Z YES 0 NO LOCATION SUPPLIES OF SYSTEM BUILDING: MAKE MODEL YEAR OF K SIN QUANTITY TEMPERATURE MANUFACTURE FACTOR RATING Reliable F1FR Pendent 2013 5.6 RA1414 126 155° F Reliable G5-56 Concealed 2013 5.6 RA3415 203 165° F SPRINKLERS PIPE AND TYPE OF PIPE: Schedule 10 MAINS) and Schedule 40 (BRANCHLINES) FITTINGS TYPE OF FITTINGS: Firelock Grooved (MAINS) and Malleable iron Class 150 (BRANCHLINES) ALARM DEVICE I MAXIMUM TIME TO OPERATE THRU TEST CONNECTION ALARM VALVE TYPE MAKE I MODEL I MIN. I SEC. OR FLOW Water Flow Switch Potter Electric VSR-F 30 I 60 INDICATOR I I DRY VALVE I Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. TIME TO TRIP TRIP POINT AIR TIME WATER ALARM THRU TEST WATER PRESSURE AIR PRESSURE PRESSURE REACHED OPERATED CONNECTION* TEST OUTLET* PROPERLY DRY PIPE MIN. SEC. PSI PSI PSI MIN. I SEC. YES NO OPERATING I TEST Without I Q.O.D. With I o o Q.O.D. I IF NO, EXPLAIN: 'MEASURED FROM TIME INSPECTOR'S TEST CONNECTION OPENED. (OVEF Western States Fire Protection Co. Western States I Fire Protection Co. ad et( 3820 Oceanic Drive, # 309 . Oceanside, CA 92056 P (760) 439-7558 F (760) 439-7655 Lic. C16-488359 OPERATION: U PNEUMATIC 0 ELECTRIC U HYDRAULIC PIPING SUPERVISED: U YES 0 NO I DETECTING MEDIA SUPERVISED: 0 YES 0 NO DOES VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL STATIONS: 0 YES 0 NO IS THERE AN ACCESSIBLE FACILITY IN U YES IF NO, DELUGE & PREACTION EACH CIRCUIT FOR TESTING: 0 NO EXPLAIN: VALVES DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT OPERATE MAXIMUM TIME TO MAKE MODEL SUPERVISION LOSS ALARM? A VALVE RELEASE? OPERATE RELEASE YES NO YES NO MIN. SEC. 0 1 0 U 1 0 Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above static pressure in excess of 150 HYDROSTATIC: psi (10.2 bars) for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. All aboveground piping TEST leakage shall be stopped. ' E •flT '," ' PNEUMATIC Establish 40 psi (2.7 bars) air pressure and measure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2.00 IF NO DRY PIPING PNEUMATICALLY TESTED: 0 YES 0 NO STATE EQUIPMENT OPERATES PROPERLY: 0 YES U NO REASON: DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR 0 YES U NO TESTING SYSTEMS OR STOPPING LEAKS? TESTS DRAIN READING OF GAGE LOCATED NEAR WATER SUPPLY TEST RESIDUAL PRESSURE WITH VALVE IN TEST TEST CONNECTION: PSI CONNECTION OPEN WIDE PSI UNDERGROUND MAIN AND LEAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING: VERIFIED BY COPY OF THE U FORM NO. 85B tR YES 0 NO OTHER FLUSHED BY INSTALLER OF UNDER- YES 0 NO EXPLAIN GROUND SPRINKLER PIPING BLANK NUMBER NUMBER REMOVED TESTING USED LOCATIONS: GASKETS WELDED PIPING: YES 0 NO IF YES: DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS YES NO OF AT LEAST AWS B2.1 ? WELDING DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE WITH THE YES NO 0 REQUIREMENTS OF AT LEAST AWS B2.1 ? DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND 0 YES 0 NO OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? CUTOUTS (DISCS) DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS (DISCS) ARE RETRIEVED? Z YES U NO HYDRAULIC DATA N IF NO, NAMEPLATE PROVIDED. YES U 0 NAMEPLATE EXPLAIN: REMARKS DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: NAME OF SPRINKLER CONTRACTOR: WESTERN STATES FIRE PROTECTION CO. TESTS WITNESSED BY 'OPVTY ER(SIGNED) DATO el SIGNATURES / v LGNED TITLE TE -ve CA?x— / e7_1v FOR RES flEMPLOYEE (SIGNED) P TITLE 'DATE ADDITIONAL EXPLANATION AND NOTES REMARKS 6 .7/7Je JJ /V42 / (Back) 'I, Western States Fire Protection Co. CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR AbWestern States Fire Protection Co. P°'.tiq. 4 amd teie. 3820 Oceanic Drive, #309 Oceanside, CA 92056 P (760) 439-7558 • F (760) 439-7655 Lic. C16-488359 A BOVEGROUND PIPING PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall b corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understoo the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approvin authority's requirements or local ordinances. PROPERTY NAME: I Date: WESTFIELD - REGAL WEST 10/14/2014 PROPERTY ADDRESS: 2501 EL CAMINO REAL, CARLSBAD, CA 92008 ACCEPTED BY APPROVING AUTHORITY(S) NAMES: CARLSBAD FIRE DEPARTMENT 1638 FARADAY AVENUE AHJ ADDRESS CARLSBAD, CA 92008 INSTALLATION CONFORMS TO ACCEPTED PLANS 0 YES El NO EQUIPMENT USED IS APPROVED 0 YES El NO PLANS IF NO, EXPLAIN DEVIATIONS: HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION Z YES 0 NO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPLAIN: INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: SYSTEM COMPONENTS INSTRUCTIONS Z YES El NO CARE AND MAINTENANCE INSTRUCTIONS YES El NO NFPA25 Z YES El NO LOCATION SUPPLIES OF SYSTEM BUILDING: MAKE MODEL YEAR OF K SIN QUANTITY TEMPERATURE MANUFACTURE FACTOR RATING Reliable F1 FR Pendent 2013 5.6 RA1414 232 155° F Reliable G5-56 Concealed 2013 5.6 RA3415 172 165° F SPRINKLERS Reliable F1 FR Upright 2013 1 5.6 1 RA1425 13 1 155° F Reliable F1 FIR Sidewall 2013 5.6 RA1435 4 155° F PIPE AND TYPE OF PIPE: Schedule 10 (MAINS) and Schedule 40 (BRANCHLINES) FITTINGS TYPE OF FITTINGS: Firelock Grooved (MAINS) and Malleable iron Class 150 (BRANCHLINES) ALARM DEVICE I MAXIMUM TIME TO OPERATE THRU TEST CONNECTION ALARM VALVE TYPE MAKE I I MODEL I MIN. SEC. OR FLOW Water Flow Switch Potter Electric I VSR-F I 30 I 60 INDICATOR I I I DRY VALVE I Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. TIME TO TRIP TRIP POINT AIR TIME WATER ALARM THRU TEST WATER PRESSURE AIR PRESSURE PRESSURE REACHED OPERATED CONNECTION* TEST OUTLET* PROPERLY DRY PIPE MIN. SEC. PSI PSI PSI MIN. I SEC. I YES NO OPERATING TEST Without I El El Q.O.D. I With El El Q.O.D. IF NO, EXPLAIN: *MEASURED FROM TIME INSPECTOR'S TEST CONNECTION OPENED. (OVEF Western States Fire Protection Co. Western States L Fire Protection Co. 3820 Oceanic Drive, # 309• Oceanside, CA 92056 P (760) 439-7558 . F (760) 439-7655 Lic. C16-488359 OPERATION: El PNEUMATIC 0 ELECTRIC 0 HYDRAULIC PIPING SUPERVISED: 0 YES 0 NO I DETECTING MEDIA SUPERVISED: 0 YES 0 NO DOES VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL STATIONS: 0 YES U NO DELUGE & IS THERE AN ACCESSIBLE FACILITY IN El YES IF NO, - PREACTION EACH CIRCUIT FOR TESTING: 0 NO EXPLAIN: VALVES DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT OPERATE MAXIMUM TIME TO MAKE MODEL SUPERVISION LOSS ALARM? A VALVE RELEASE? OPERATE RELEASE YES NO YES NO MIN. SEC. 0 0 0 0 9 Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above static pressure in excess of 150 HYDROSTATIC: psi (10.2 bars) for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. All aboveground piping TEST leakage shall be stopped. DESCRIPTION Establish 40 psi (2.7 bars) air pressure and measure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. Test pressure tanks at PNEUMATIC normal water level and air pressure and measure air pressure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2.00 IF NO DRY PIPING PNEUMATICALLY TESTED: 0 YES 0 NO STATE EQUIPMENT OPERATES PROPERLY: 0 YES U NO REASON: DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR 0 YES NO TESTING SYSTEMS OR STOPPING LEAKS? TESTS DRAIN READING OF GAGE LOCATED NEAR WATER SUPPLY TEST RESIDUAL PRESSURE WITH VALVE IN TEST TEST CONNECTION: PSI CONNECTION OPEN WIDE PSI UNDERGROUND MAIN AND LEAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING: VERIFIED BY COPY OF THE U FORM NO. 85B JR YES 0 NO OTHER FLUSHED BY INSTALLER OF UNDER- YES 0 NO EXPLAIN GROUND SPRINKLER PIPING BLANK NUMBER NUMBER REMOVED TESTING USED LOCATIONS: GASKETS WELDED PIPING: YES NO IF YES: DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS YES 0 NO OF AT LEAST AWS B2.1 ? WELDING DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE WITH THE DYES 0 NO REQUIREMENTS OF AT LEAST AWS B2.1 ? DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND 0 YES 0 NO OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? CUTOUTS (DISC S) DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS (DISCS) ARE RETRIEVED? Z YES 0 NO HYDRAULIC DATA NA PROVIDED: NO IF NO, NAMEPLATE PR D YES NAMEPLATE . EXPLAIN: REMARKS DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: NAME OF SPRINKLER CONTRACTOR: WESTERN STATES FIRE PROTECTION CO. TESTS WITNESSED BY ,X 7OR PROP TY OWNER (SIGNED) SIGNATURES C CTOR (SIGNED) fITU DATE TITLE FOR RESPONsIBkANA (SIGNED) V TITLE DA'rE ADDITIONAL EXPLANATION AND NOTES REMARKS (Back) ol Western States Fire Protfcii& Western States 1 1116 Fire Protection Co. il 4au 44d 17 3820 Oceanic Drive, #309 Oceanside, CA 92056 - P (760) 439-7558 • F (760) 439-7655 Lic. C16-488359 CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR A BOVEGROUND PIPING PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall bE corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understoo the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approvin authority's requirements or local ordinances. PROPERTY NAME: I Date: WESTFIELD -24 HR FITNESS 10/14/2014 PROPERTY ADDRESS: 2501 EL CAMINO REAL, CARLSBAD, CA 92008 ACCEPTED BY APPROVING AUTHORITY(S) NAMES: CARLSBAD FIRE DEPARTMENT 1638 FARADAY AVENUE AHJ ADDRESS CARLSBAD, CA 92008 INSTALLATION CONFORMS TO ACCEPTED PLANS YES 0 NO EQUIPMENT USED IS APPROVED Z YES 0 NO PLANS IF NO, EXPLAIN DEVIATIONS: HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION YES 0 NO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPLAIN: INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: SYSTEM COMPONENTS INSTRUCTIONS Z YES 0 NO CARE AND MAINTENANCE INSTRUCTIONS YES 0 NO NFPA25 YES 0 NO LOCATION SUPPLIES OF SYSTEM BUILDING: MAKE MODEL YEAR OF MANUFACTURE K FACTOR SIN QUANTITY RATING TEMPERATURE Reliable F1 FR Upright 2013 5.6 RA1425 370 155° F SPRINKLERS PIPE AND TYPE OF PIPE: Schedule 10 (MAINS) and Schedule 40 (BRANCHLINES) . FITTINGS TYPE OF FITTINGS: Firelock Grooved (MAINS) and Malleable iron Class 150 (BRANCHLINES) ALARM DEVICE I I MAXIMUM TIME TO OPERATE THRU TEST CONNECTION ALARM VALVE TYPE MAKE I MODEL I MIN. I I SEC. OR FLOW Water Flow Switch Potter Electric I VSR-F 30 60 INDICATOR DRY VALVE I Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. TIME TO TRIP TRIP POINT AIR TIME WATER ALARM THRU TEST WATER PRESSURE AIR PRESSURE PRESSURE REACHED OPERATED CONNECTION* TEST OUTLET* PROPERLY MIN. I SEC. PSI PSI PSI MIN. SEC. YES NO DRY PIPE OPERATING TEST Without I 0 El Q.O.D. With I 0 El Q.O.D. IF NO, EXPLAIN: *MEASURED FROM TIME INSPECTOR'S TEST CONNECTION OPENED. - (OVEN Western States Fire Protection Co. States M'j()West;rn rotection Co. p4mae4*.&VA 4Nd 3820 Oceanic Drive, #309 Oceanside, CA 92056 P (760) 439-7558 • F (760) 439-7655 Lic. C16-488359 OPERATION: D PNEUMATIC 0 ELECTRIC 0 HYDRAULIC PIPING SUPERVISED: 0 YES 0 NO I DETECTING MEDIA SUPERVISED: 0 YES 0 NO DOES VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL STATIONS: 0 YES 0 NO - DELUGE & IS THERE AN ACCESSIBLE FACILITY IN 0 YES IF NO, PREACTION EACH CIRCUIT FOR TESTING: 0 NO EXPLAIN: VALVES DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT OPERATE MAXIMUM TIME TO MAKE MODEL SUPERVISION LOSS ALARM? A VALVE RELEASE? OPERATE RELEASE YES NO YES NO MIN. SEC. 0 0 0 0 Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above static pressure in excess of 150 HYDROSTATIC: psi (10.2 bars) for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. All aboveground piping TEST leakage shall be stopped. l-ESR,pT', DESCRIPTION Establish 40 psi (2.7 bars) air pressure and measure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. Test pressure tanks at PNEUMATIC normal water level and air pressure and measure air pressure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2.00 IF NO DRY PIPING PNEUMATICALLY TESTED: 0 YES 0 NO STATE EQUIPMENT OPERATES PROPERLY: 0 YES 0 NO REASON: DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR 0 YES 0 NO TESTING SYSTEMS OR STOPPING LEAKS? TESTS DRAIN READING OF GAGE LOCATED NEAR WATER SUPPLY TEST RESIDUAL PRESSURE WITH VALVE IN TEST TEST CONNECTION: PSI CONNECTION OPEN WIDE PSI UNDERGROUND MAIN AND LEAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING: VERIFIED BY COPY OF THE U FORM NO. 85B YES 0 NO OTHER FLUSHED BY INSTALLER OF UNDER- YES 0 NO EXPLAIN GROUND SPRINKLER PIPING BLANK NUMBER NUMBER REMOVED TESTING USED LOCATIONS: GASKETS WELDED PIPING: YES 0 NO IF YES: DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS YES 0 NO OF AT LEAST AWS B2.1 ? WELDING DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE WITH THE YES NO 0 REQUIREMENTS OF AT LEAST AWS 82.1? DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND YES 0 NO OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? CUTOUTS (DISCS) DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS (DISCS) ARE RETRIEVED? YES 0 NO HYDRAULIC DATA IF NO, NAME PLATE PROVIDED. YES N EXPLAIN: NAMEPLATE REMARKS DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: NAME OF SPRINKLER CONTRACTOR: WESTERN STATES FIRE PROTECTION CO. TESTS WITNESSED BY OR PROI ER OWNER(SIGNED) DATE ?,,t k 'd 92 SIGNATURES / R PR L TRACTOR (SIGNED) TITLE DATE -- 4i1'P --, FOR LOC SHAL($IQNF\ TITLE D4TE FOR SP AGIN PLO (SIGNED) U TITLE ATE ADDITIONAL EXPLANATION AND NOTES REMARKS ,'3'/P6 1c4L/ (Back D "7 AbWestern statesFire Protection Co. '"4't I(,aed 4g1 Øee 3820 Oceanic Drive, # 309 Oceanside, CA 92056 \Vestern States Fire Protection CI1' (760) 439-7558 • F (760) 439-7655 Lic, C16-488359 CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR U NDERGROUND PIPING PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall b corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understoo the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approvin, authority's requirements or local ordinances. PROPERTY NAME: Date: WESTFIELD MALL CARLSBAD 10/14/2014 PROPERTY ADDRESS: 2501 EL CAMINO REAL, CARLSBAD, CA 92008 ACCEPTED BY APPROVING AUTHORITY(S) NAMES: Carlsbad Fire Department AHJ ADDRESS 1638 Faraday Avenue Carlsbad, CA 92008 INSTALLATION CONFORMS TO ACCEPTED PLANS YES El, NO PLANS EQUIPMENT USED IS APPROVED YES 0 NO IF NO, EXPLAIN DEVIATIONS: HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION YES NO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPLAIN: INSTRUCTIONS HAVE COPIES OF APPROPRIATE INSTRUCTIONS AND CARE AND MAINTENANCE CHARTS BEEN LEFT ON THE YES o NO PREMISES? IF NO, EXPLAIN: LOCATION SUPPLIES stfield Regal Cinema, 24hr Fitness ,/ PIPE TYPES AQCLASS: - TYPE JOINT: C.900 CLASS 1IOWTCML-DI MECHANICAL JOINT PIPE CONFORMS TO NFPA#24 STANDARD 0 YES El NO UNDERGROUND FITTINGS CONFORM TO NFPA#24 STANDARD Z YES 0 NO PIPES AND IF NO, EXPLAIN: JOINTS JOINTS NEEDING ANCHORAGE CLAMPED, STRAPPED, OR BLOCKED IN Z YES El NO ACCORDANCE WITH NFPA#24 STANDARD IF NO, EXPLAIN: FLUSHING. Flow the required rate until water is cleasindicated by no collection of foreign material in burlap bags at outlets such as hydrants and blow-offs. Flush at flows not less than 390 GPM (1476 LJmin) for 4nch 880 GPM (3331 LJmin) for 6-inch pipe, 1560 GPM (5905 Llmin) for 8-inch pipe, 2440 GPM pipe, (9235 L/min) for 10-inch pipe, and 3520 GPM (13323 L/min) for 12-inch pipe. When supply cannot produce stipulated flow rates, obtain maximum available. HYDROSTATIC. Hydrostatic tests shall be made not less than 200 psi (13.8 bars) for two hours or 50 psi (3.4 bars) above static pressure in excess of 150 psi TEST (10.3 bars) for two hours. DESCRIPTION LEAKAGE. New pipe laid with rubber gasketed joints shall, if the workmanship is satisfactory, have little or no leakage at the joints. The amount of leakage at the joints shall not exceed 2 qts. Per hr. (1.89 Lih) per 100 joints irrespective of pipe diameter. The leakage shall be distributed overall joints. If such leakage occurs at a few joints the installation shall be considered unsatisfactory and necessary repairs made. The amount of allowable leakage specified above may be increased by 1 f. Oz per in. Valve diameter per hr. (30 mU25 mm/h) for each metal seated valve isolating the test section. If dry barrel hydrants are tested with the main valve open, so the hydrants are under pressure, an additional 5 oz per minute (150 mL/min) leakage is permitted for each hydrant. NEW UNDERGROUND PIPING FLUSHED ACCORDING TO NFPA #24 STANDARD Z YES El NO BY (COMPANY): WESTERN STATES FIRE PROTECTION IF NO, EXPLAIN: HOW FLUSHING FLOW WAS OBTAINED THROUGH WHAT TYPE OPENING FLUSHING D PUBLIC WATER El TANK OR RESERVOIR El FIRE PUMP 0 HYDRANT BUTT OPEN PIPE TESTS LEAD-INS FLUSHED ACCORDING TO NFPA #24 STANDARD 0 YES El NO BY (COMPANY): WESTERN STATES FIRE PROTECTION IF NO, EXPLAIN: HOW FLUSHING WAS OBTAINED THROUGH WHAT TYPE OPENING 0 PUBLIC WATER El TANK OR RESERVOIR ' El FIRE PUMP 0 V CONN. TO FLANGE & SPIGOT 9 OPEN PIPE ObWestern States Fire Protection Co. 4 ad Pmtq Western States Fire Protection Co. 3820 Oceanic Drive, # 309 • Oceanside, CA 92056 P (760) 439-7558 F (760) 439-7655 Lic. C16-488359 HYDROSTATIC ALL NEW UNDERGROUND PIPING HYDROSTATICALLY TESTED AT JOINTS COVERED: TEST 200 PSI FOR 2 HOURS YES 0 NO TOTAL AMOUNT OF LEAKAGE MEASURED LEAKAGE GALLONS HOURS TEST ALLOWABLE LEAKAGE GALLONS HOURS HYDRANTS NUMBER INSTALLED TYPE AND MAKE ALL OPERATE ATISFACTORILY 0 DYES ONO WATER CONTROL VALVES LEFT WIDE OPEN 0 YES D NO CONTROL IF NO, STATE REASON: N/A VALVES HOSE THREADS OF FIRE DEPARTMENT CONNECTIONS AND HYDRANTS INTERCHANGEABLE WITH THOSE OF FIRE DEPARTMENT ANSWERING ALARM 0 YES 0 NO REMARKS DATE LEFT IN SERVICE: 9/29/2014 NAME OF SPRINKLER CONTRACTOR: WESTERN STATES FIRE PROTECTION CO. TESTS WITNESSED BY PROPER OWNER (SIGNED) 1 Z4 fATE~~ / /ro CONTRACTOR (SIGNED) TITLE DATE SIGNATURES _____~ GING _SH -1iTLE ~FOR DATE SPONSIBLE MPLOYEE (SIGNED) TITLE DATE ADDITIONAL EXPLANATION AND NOTES (BACK) As i4c) i i c 4i.ku.r QitJC - - - Fire Protection by Computer Design Western Staes Fire Protection 3820 Oceanic Drive Suite 309 Oceanside, Ca 92056 760-439-7558 Job Name : Westfiled Carlsbad - AS-BUILT PROOF Building FP-7.1 Location : CARLSBAD, CA 90067 System : R9 Contract : QT0012 Data File : FP-3rd Level Rev 4 AREA 1 .wxf Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Western Staes Fire Protection Page 1 Westfiled Carlsbad - AS-BUILT PROOF Date 12/2/12 HYDRAULIC CALCULATIONS for Project name: WESTFIELD CARLSBAD Location: CARLSBAD, CA 90067 Drawing no: FP-7.1 Date: 12/2/14 Design Remote area number: R9 Remote area location: 3RD FLOOR AUDITORIUM 1 - WORST CASE AS-BUILT Occupancy classification: ORD GRP II Density: 0.2 - Gpm/SqFt Area of application: 2529 - SqFt Coverage per sprinkler: 120 - SqFt Type of sprinklers calculated: RELIABLE G5-56 CONCEALED No, of sprinklers calculated: 25 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 872.898 -GPM @ 84.784 -Psi Type of system: WET Volume of dry or preaction system: N/A - Gal Water supply information Date: 1/27/14 Location: 2525 EL CAMINO REAL Source: WESTERTN STATES FIRE PROTECTION CO. Name of contractor: WESTERN STATES FIRE PROTECTION CO. Address: 3720 INDUSTRY AVE., SUITE 107 LAKEWOOD, CA 90712 Phone number: (562) 279-0770 Name of designer: JEFF HOWELL Authority having jurisdiction: CITY OF CARLSBAD Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Western Staes Fire Protection Westfiled Carlsbad - AS-BUILT PROOF Page 2 Date 12/2/12 City Water Supply: Demand: - Cl - Static Pressure : 96.3 Dl - Elevation : 25.839 C2 - Residual Pressure: 82.3 D2 - System Flow : 621.941 02 - Residual Flow : 1272 D2 - System Pressure : 86.812 Hose ( Demand) : 250 03 - System Demand :871.941 Safety Margin : 2.526 150 - 140 130 - p120 - R 11 - E10° D2 90 - S 80 - 03 U70 I R6° - E5° - 40 - 30 - 20 - 10 I 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Western Staes Fire Protection Page 3 Westfiled Carlsbad - AS-BUILT PROOF Date 12/2t12 Fitting Legend Abbrev. Name 1/ % 1 1 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 Bvcb B Fly Vic 705W 0 0 0 0 0 0 5 5 0 12 12 8 11 12 14 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow C NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90' Ell Firelock#001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0 X 90'Tee-BranchFirelock002 0 0 0 0 0 8.5 10.8 13 0 16 21 25 33 0 0 0 0 0 0 0 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Western Staes Fire Protection Page 4 Westfiled Carlsbad - AS-BUILT PROOF Date 12/2/12 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. DPO1 59.66 5.6 18.37 na 24.0 0.2 120 7.0 EQ01 46.75 27.13 na DP02 59.66 5.6 18.37 na 24.0 0.2 120 7.0 EQ02 46.583 27.24 na DP03 59.66 5.6 18.37 na 24.0 0.2 120 7.0 EQ03 46.083 27.55 na DP04 59.66 5.6 18.37 na 24.0 0.2 120 7.0 EQ04 45.5 27.9 na DPOS 59.66 5.6 18.37 na 24.0 0.2 120 7.0 EQ05 44.916 28.26 na DP06, 59.66 5.6 18.37 na 24.0 0.2 120 7.0 EQ06 44.333 28.62 na DP07 59.66 5.6 18.37 na 24.0 0.2 120 7.0 EQ07 43.75 28.98 na S1O1 59.66 K= K @ EQ01 27.13 na 24.0 S102 59.66 K = K @ EQ02 27.28 na 24.02 S103 59.66 K = K @ EQ03 27.94 na 24.17 S104 59.66 K= K @ EQ04 29.34 na 24.61 S107 59.66 K = K @ EQ07 29.03 na 24.02 S106 59.66 K = K @ E006 29.21 na 24.25 S105 59.66 K = K @ EQ05 29.88 na 24.68 RN01 59.66 32.36 na RN02 58.91 40.58 na RN04 58.91 40.65 na M101 58.91 41.3 na M102 58.91 47.6 na M103 58.91 48.21 na M104 58.91 48.25 na M105 55.66 50.75 na M106 55.66 51.02 na M107 55.66 51.54 na TOR 55.66 52.18 na BOR 36.12 60.87 na BOR3 24.58 67.61 na RSR1 15.75 73.5 na RSR2 2.625 79.82 na UGI -3.0 82.42 na TEST 0.0 86.81 na 250.0 S120 59.66 K = K © EQOl 28.54 na 24.61 S121 59.66 K = K © EQ02 28.69 na 24.63 S122 59.66 K = K @ EQ03 29.39 na 24.79 S123 59.66 K = K © EQ04 30.86 na 25.24 S125 59.66 K= K© EQ06 32.51 na 25.58 S124 59.66 K= K@ EQOS 32.72 na 25.82 RN07 59.66 34.01 na RN08 58.91 40.67 na RN06 58.91 40.73 na S108 59.66 K= K@ EQ01 28.53 na 24.61 S109 59.66 K= K@ EQ02 28.68 na 24.63 Silo 59.66 K= K@ EQ03 29.37 na 24.78 Sill 59.66 K = K © EQ04 30.84 na 25.23 S113 59.66 K = K @ EQ06 32.49 na 25.57 8112 59.66 K= K@ EQ05 32.7 na 25.82 RN03 59.66 34.0 na S114 59.66 K= K© EQOI 28.57 na 24.63 S115 59.66 K = K @ EQ02 28.72 na 24.65 S116 59.66 K=K@EQO2 29.41 na 24.94 S117 59.66 K= K@ EQ04 30.89 na 25.25 S119 59.66 K=K@EQO6 32.55 na 25.6 S118 59.66 K = K © EQ05 32.76 na 25.84 RN05 59.66 34.06 na The maximum velocity is 24.51 and it occurs in the pipe between nodes RN01 and RN02 Comouter Proarams by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Staes Fire Protection Page 5 Westfiled Carlsbad - AS-BUILT PROOF Date 12/2/12 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Fe Fv ******* Notes ****** Point Qt P1/Ft Eqv. Ln. Total Ff Fn *EQUIVALENT K'S DP01 24.00 1.049 2E 4.0 8.416 18.367 K Factor =5.60 to 120.0 T 5.0 9.000 5.591 EQ01 24.0 0.1824 0.0 17.416 3.176 Vel = 8.91 0.0 24.00 27.134 K Factor= 4.61 DP02 24.00 1.049 2E 4.0 8.583 18.367 K Factor =5.60 to 120.0 T 5.0 9.000 5.664 EQ02 24.0 0.1823 0.0 17.583 3.206 Vel = 8.91 0.0 24.00 27.237 K Factor = 4.60 DP03 24.00 1.049 2E 4.0 9.125 18.367 K Factor =5.60 to 120.0 T 5.0 9.000 5.880 EQ03 24.0 0.1823 0.0 18.125 3.305 Vel = 8.91 0.0 24.00 27.552 K Factor = 4.57 DP04 24.00 1.049 2E 4.0 9.670 18.367 K Factor = 5.60 to 120.0 1 5.0 9.000 6.133 EQ04 24.0 0.1823 0.0 18.670 3.404 Vel = 8.91 0.0 24.00 27.904 K Factor = 4.54 DPO5 24.00 1.049 2E 4.0 10.250 18.367 K Factor =5.60 to 120.0 1 5.0 9.000 6.386 EQ05 24.0 0.1823 0.0 19.250 3.510 Vel = 8.91 0.0 24.00 28.263 K Factor = 4.51 DP06 24.00 1.049 2E 4.0 10.833 18.367 K Factor =5.60 to 120.0 T 5.0 9.000 6.638 EQ06 24.0 0.1824 0.0 19.833 3.617 Vel = 8.91 0.0 24.00 28.622 K Factor= 4.49 DP07 24.00 1.049 2E 4.0 11.416 18.367 K Factor =5.60 to 120.0 T 5.0 9.000 6.891 EQ07 24.0 0.1823 0.0 20.416 3.722 Vel = 8.91 0.0 24.00 28.980 K Factor = 4.46 *REMOTE HEAD TO SUPPLY S10I 24.00 1.682 0.0 8.000 27.134 K Factor @ node EQ01 to 120.0 0.0 0.0 0.0 S102 24.0 0.0182 0.0 8.000 0.146 Vel = 3.47 S102 24.02 1.682 0.0 10.000 27.280 K Factor @ node EQ02 to 120.0 0.0 0.0 0.0 S103 48.02 0.0660 0.0 10.000 0.660 Vel = 6.93 S103 24.17 1.682 0.0 10.000 27.940 K Factor@ node EQ03 to 120.0 0.0 0.0 0.0 S104 72.19 0.1403 0.0 10.000 1.403 Vel = 10.42 ComDuter Pronrams by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Staes Fire Protection Page 6 Westfiled Carlsbad - AS-BUILT PROOF Date 12/2/12 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "Cl,or Ftng's Pe Pv ******* Notes ****** Point Qt P1/Ft Eqv. Ln. Total P1 Pn S104 24.61 1.682 1 9.9 2.580 29.343 K Factor@ node EQ04 to 120.0 0.0 9.900 0.0 RN01 96.8 0.2414 0.0 12.480 3.013 Vel = 13.98 0.0 96.80 32.356 K Factor 17.02 *NEW PATH S107 24.02 1.682 0.0 10.000 29.030 K Factor @ node EQ07 to 120.0 0.0 0.0 0.0 S106 24.02 0.0183 0.0 10.000 0.183 Vet = 3.47 S106 24.25 1.682 0.0 10.000 29.213 K Factor @ node EQ06 to 120.0 0.0 0.0 0.0 S105 48.27 0.0667 0.0 10.000 0.667 Vet = 6.97 5105 24.67 1.682 T 9.9 7.416 29.880 K Factor @ node EQ05 to 120.0 0.0 9.900 0.0 RN01 72.94 0.1430 0.0 17.316 2.476 VeI= 10.53 RN01 96.80 1.682 1 9.9 1.670 32.356 to 120.0 0.0 9.900 0.325 RN02 169.74 0.6824 0.0 11.570 7.895 Vel = 24.51 RN02 0.0 4.26 0.0 10.000 40.576 to 120.0 0.0 0.0 0.0 RN04 169.74 0.0073 0.0 10.000 0.073 Vet = 3.82 RN04 150.63 4.26 X 21.067 6.330 40.649 to 120.0 0.0 21.067 0.0 MIOI 320.37 0.0239 0.0 27.397 0.656 Vet = 7.21 MIOI 301.57 4.26 X 21.067 56.100 41.305 to 120.0 0.0 21.067 0.0 M102 621.94 0.0816 0.0 77.167 6.299 VeI= 14.00 M102 0.0 6.357 0.0 51.920 47.604 to 120.0 0.0 0.0 0.0 M103 621.94 0.0116 0.0 51.920 0.604 Vel= 6.29 M103 0.0 6.357 0.0 3.670 48.208 to 120.0 0.0 0.0 0.0 M104 621.94 0.0114 0.0 3.670 0.042 Vel = 6.29 M104 0.0 6.357 2V 25.147 37.160 48.250 to 120.0 X 31.433 56.580 1.408 M105 621.94 0.0116 0.0 93.740 1.089 Vel = 6.29 M105 0.0 6.357 0.0 23.620 50.747 to 120.0 0.0 0.0 0.0 M106 621.94 0.0116 0.0 23.620 0.275 VeI= 6.29 M106 0.0 6.357 0.0 45.000 51.022 to 120.0 0.0 0.0 0.0 M107 621.94 0.0116 0.0 45.000 0.523 Vel = 6.29 M107 0.0 6.357 2V 25.147 29.210 51.545 to 120.0 0.0 25.147 0.0 TOR 621.94 0.0116 0.0 54.357 0.631 Vet = 6.29 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Staes Fire Protection Page 7 Westfiled Carlsbad - AS-BUILT PROOF Date 12/2/12 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. lici t or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn TOR 0.0 6.357 0.0 19.540 52.176 to 120.0 0.0 0.0 8.463 BOR 621.94 0.0116 0.0 19.540 0.227 Vel = 6.29 BOR 0.0 6.357 V 16.723 13.000 60.866 to 140.0 Bvcb 13.378 71.908 5.998 **Fixed Loss ...1 BOR3 621.94 0.0087 Fsp 0.0 84.908 0.742 Vel = 6.29 X 41.807 BOR3 0.0 6.357 5V 62.867 115.000 67.606 to 120.0 0.0 62.867 3.824 RSR1 621.94 0.0116 0.0 177.867 2.067 Vel = 6.29 RSRI 0.0 6.357 X 31.433 13.125 73.497 to 120.0 Bvcb 10.059 41.492 5.684 RSR2 621.94 0.0116 0.0 54.617 0.636 Vel = 6.29 RSR2 0.0 8.249 2V 30.537 22.080 79.817 to 120.0 0.0 30.537 2.436 UG1 621.94 0.0033 0.0 52.617 0.172 Vel = 3.73 UG1 0.0 7.98 Zaf 0.0 146.910 82.425 to 140.0 4E 95.702 194.062 3.403 * * Fixed Loss = 4.702 TEST 621.94 0.0029 2T 93.043 340.972 0.984 Vel = 3.99 C 5.317 250.00 Qa 250.00 871.94 86.812 KFactor= 93.58 *NEW PATH S120 24.61 1.682 0.0 8.000 28.540 K Factor @ node EQ01 to 120.0 0.0 0.0 0.0 S121 24.61 0.0192 0.0 8.000 0.154 VeI= 3.55 S121 24.64 1.682 0.0 10.000 28.694 K Factor @node EQ02 to 120.0 0.0 0.0 0.0 S122 49.25 0.0691 0.0 10.000 0.691 Vel = 7.11 S122 24.78 1.682 0.0 10.000 29.385 K Factor @ node EQ03 to 120.0 0.0 0.0 0.0 S123 74.03 0.1470 0.0 10.000 1.470 Vel = 10.69 S123 25.24 1.682 T 9.9 2.583 30.855 K Factor @ node EQ04 to 120.0 0.0 9.900 0.0 RN07 99.27 0.2529 0.0 12.483 3.157 Vel = 14.33 0.0 99.27 34.012 KFactor= 17.02 *NEW PATH S125 25.58 1.682 0.0 10.000 32.510 K Factor @ node EQ06 to 120.0 0.0 0.0 0.0 S124 25.58 0.0206 0.0 10.000 0.206 Vel = 3.69 S124 25.82 1.682 T 9.9 7.420 32.716 K Factor @ node EQOS to 120.0 0.0 9.900 0.0 RN07 51.4 0.0748 0.0 17.320 1.296 Vel = 7.42 RN07 99.27 1.682 T 9.9 1.670 34.012 to 120.0 0.0 9.900 0.325 RN08 150.67 0.5474 0.0 11.570 6.333 Vel = 21.76 C,ornputr Prograrns by Hvdratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Staes Fire Protection Page 8 Westfiled Carlsbad - AS-BUILT PROOF Date 12/2/12 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn RN08 0.0 4.26 0.0 10.670 40.670 to 120.0 0.0 0.0 0.0 RN06 150.67 0.0059 0.0 10.670 0.063 Vel = 3.39 RN06 150.90 4.26 X 21.067 5.670 40.733 to . 120.0 0.0 21.067 0.0 M1O1 301.57 0.0214 0.0 26.737 0.572 Vel = 6.79 0.0 301.57 41.305 KFactor= 46.92 *NEW PATH S108 24.61 1.682 0.0 8.000 28.526 K Factor @ node EQ01 to 120.0 0.0 0.0 0.0 S109 24.61 0.0191 0.0 8.000 0.153 Vel = 3.55 S109 24.62 1.682 0.0 10.000 28.679 K Factor @node EQ02 to 120.0 0.0 0.0 0.0 SilO 49.23 0.0691 0.0 10.000 0.691 Vel = 7.11 5110 24.78 1.682 0.0 10.000 29.370 K Factor @ node EQ03 to 120.0 0.0 0.0 0.0 Sill 74.01 0.1469 0.0 10.000 1.469 Vel= 10.69 Sill 25.23 1.682 T 9.9 2.583 30.839 K Factor @ node EQ04 to 120.0 0.0 9.900 0.0 RN03 99.24 0.2528 0.0 12.483 3.156 Vel = 14.33 0.0 99.24 33.995 K Factor = 17.02 *NEW PATH S113 25.57 1.682 0.0 10.000 32.494 K Factor @ node EQ06 to 120.0 0.0 0.0 0.0 S112 25.57 0.0206 0.0 10.000 0.206 Vel = 3.69 S112 25.82 1.682 T 9.9 7.420 32.700 K Factor @ node EQ05 to 120.0 0.0 9.900 0.0 RN03 51.39 0.0748 0.0 17.320 1.295 Vel = 7.42 RN03 99.24 1.682 T 9.9 1.670 33.995 to 120.0 0.0 9.900 0.325 RN04 150.63 0.5470 0.0 11.570 6.329 Vel = 21.75 0.0 150.63 40.649 K Factor= 23.63 *NEW PATH S114 24.63 1.682 0.0 8.000 28.567 K Factor @ node EQOl to 120.0 0.0 0.0 0.0 S115 24.63 0.0192 0.0 8.000 0.154 Vel = 3.56 S115 24.64 1.682 0.0 10.000 28.721 K Factor @ node EQ02 to 120.0 0.0 0.0 0.0 S116 49.27 0.0692 0.0 10.000 0.692 Vel= 7.11 S116 24.94 1.682 0.0 10.000 29.413 K Factor @ node EQ02 to 120.0 0.0 0.0 0.0 S117 74.21 0.1477 0.0 10.000 1.477 Vel= 10.72 Cqmpjr Procirams by Hydratec Inc. Route 111 Windham N.H. USA 03087 ) Final Calculations - Hazen-Williams Western Staes Fire Protection Page 9 Westfiled Carlsbad - AS-BUILT PROOF Date 12/2/12 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn S117 25.25 1.682 T 9.9 2.583 30.890 K Factor @ node EQO4 to 120.0 0.0 9.900 0.0 RN05 99.46 0.2538 0.0 12.483 3.168 Vel = 14.36 0.0 99.46 34.058 K Factor = 17.04 *NEW PATH S119 25.60 1.682 0.0 10.000 32.554 K Factor @ node EQ06 to 120.0 0.0 0.0 0.0 S118 25.6 0.0206 0.0 10.000 0.206 Vel = 3.70 S118 25.83 1.682 T 9.9 7.420 32.760 K Factor@ node EQ05 to 120.0 0.0 9.900 0.0 RN05 51.43 0.0749 0.0 17.320 1.298 Vel = 7.43 RN05 99.47 1.682 1 9.9 1.670 34.058 to 120.0 0.0 9.900 0.325 RN06 150.9 0.5488 0.0 11.570 6.350 Vel = 21.79 0.0 150.90 -- 40.733 KFactor= 23.64 Comuter Proqrams by Hydratec Inc. Route 111 Windham N.H. USA 03087 in AS i4°tt, çc i4'R J Western Staes Fire Protection 3820 Oceanic Drive Suite 309 Oceanside, Ca 92056 760-439-7558 Job Name : Westfield Mall Carlsbad Building : FP-5.1 Location CARLSBAD, CA 92008 System : R7 Contract : QT0012 Data File FP-lst Level AREA 7 - FM.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Western Staes Fire Protection Westfield Mall Carlsbad . HYDRAULIC CALCULATIONS for Project name: WESTFIELD CARLSBAD Location: CARLSBAD, CA 92008 Drawing no: FP-6.1 Date: 4/7/14 Design Remote area number: R7 Remote area location: 1ST FLR - 25HR FITNESS SHELL Occupancy classification: ORDINARY HAZARD 2 Density: 0.2 - Gpm/SqFt Area of application: 1577 - SqFt Coverage per sprinkler. 130 MAX - SqFt Type of sprinklers calculated: RELIABLE Fl FR56 SSU No. of sprinklers calculated: 15 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 596.78 -GPM @ 70.59 -Psi Type of system: WET Volume of dry or preaction system: N/A - Gal Water supply information Date: 1/27/14 Location: 2525 EL CAMINO REAL Source: WESTERTN STATES FIRE PROTECTION CO. Name of contractor: WESTERN STATES FIRE PROTECTION CO. Address: 3720 INDUSTRY AVE., SUITE 107 LAKEWOOD, CA 90712 Phone number: (562) 279-07 Name ofdesigner: JEFF HOWELL Authority having jurisdiction: CITY OF CARLSBAD Notes: (Include peaking information or gridded systems here.) Page 1 Date 4/7/14 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Sup Curve (C) • Western Staes ire Protection Page 2 Westfield Mall Carlsbad Date 4/7/14 City Water Suppjy: Demand: Cl - Static Pressure : 96.3 Dl - Elevation : 4.946 C2 - Residual Pressure: 82.3 D2 - System Flow : 346.781 C2 - Residual Flow : 1272 D2 - System Pressure : 70.597 Hose ( Demand) : 250 D3 - System Demand : 596.781 Safety Margin : 22.250 150 140 130 p120 R° E10° S 90 - - ___________ S 80 - D2 U70 D R6° E5° 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings UsSummary 0 Western Staes ire Protection Page 3 Westfield Mall Carlsbad Date 4/7/14 Fitting Legend Abbrev. Name % ~ 1 11/4 11/2 2 2Y2 3 3% 4 5 6 8 10 12 14 16 18 20 24 Bvcb B Fly Vic 705W 0 0 0 0 0 0 5 5 0 12 12 8 11 12 14 0 0 0 0 0 C Roll Groove Coupling 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90' Ell Firelock#001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0 X 90'Tee-BranchFirelock002 0 0 0 0 0 8.5 10.8 13 0 16 21 25 33 0 0 0 0 0 0 0 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Western Staes Fire Protection Page 4 Westfield Mall Carlsbad Date 4/7/14 , de Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. S701 13.92 5.6 16.17 na 22.52 0.2 112.58 7.0 S702 13.92 5.6 16.31 na 22.61 0.2 112.58 7.0 S703 13.92 5.6 16.89 na 23.01 0.2 112.58 7.0 S704 13.92 5.6 17.98 na 23.75 0.2 112.58 7.0 S705 13.92 5.6 19.88 na 24.97 0.2 112.58 7.0 S706 13.92 5.6 23.26 na 27.01 0.2 112.58 7.0 S707 13.92 5.6 27.62 na 29.43 0.2 112.58 7.0 A 13.92 34.63 na S708 13.92 5.6 16.2 na 22.54 0.2 112.58 7.0 S709 13.92 5.6 16.34 na 22.64 0.2 112.58 7.0 S710 13.92 5.6 16.93 na 23.04 0.2 112.58 7.0 S711 13.92 5.6 18.02 na 23.77 0.2 112.58 7.0 S712 13.92 5.6 19.92 na 25.0 0.2 112.58 7.0 S713 13.92 5.6 23.31 na 27.04 0.2 112.58 7.0 S714 13.92 5.6 27.67 na 29.46 0.2 112.58 7.0 B 13.92 34.7 na M701 13.25 49.43 na M702 13.25 49.53 na M703 13.25 49.93 na M704 13.25 55.26 na M705 13.25 57.86 na 10R7 12.75 59.14 na BOR7 1.625 65.38 na UG1 1.625 65.43 na TEST 2.5 70.6 na 250.0 Oe maximum velocity is 25.05 and it occurs in the pipe between nodes S714 and B Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Staes Fire Protection Westfield Mall Carlsbad ,yd. Qa Dia. Fitting Pipe Pt Pt ef. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total P1 Pn Page 5 Date 4/7/14 Notes S701 22.52 1.682 0.0 8.660 16.166 K Factor =5.60 to 120.0 0.0 0.0 0.0 S702 22.52 0.0163 0.0 8.660 0.141 Vel = 3.25 S702 22.61 1.682 1C 1.237 8.660 16.307 K Factor = 5.60 to 120.0 0.0 1.237 0.0 S703 45.13 0.0588 0.0 9.897 0.582 Vel = 6.52 S703 23.01 1.682 0.0 8.660 16.889 K Factor =5.60 to 120.0 0.0 0.0 0.0 S704 68.14 0.1261 0.0 8.660 1.092 Vel= 9.84 S704 23.75 1.682 0.0 8.660 17.981 K Factor = 5.60 to 120.0 0.0 0.0 0.0 S705 91.89 0.2193 0.0 8.660 1.899 Vel = 13.27 S705 24.97 1.682 1 C 1.237 8.660 19.880 K Factor = 5.60 to 120.0 0.0 1.237 0.0 S706 116.86 0.3420 0.0 9.897 3.385 Vel= 16.87 S706 27.01 1.682 0.0 8.660 23.265 K Factor = 5.60 to 120.0 0.0 0.0 0.0 S707 143.87 0.5024 0.0 8.660 4.351 Vel = 20.77 29.43 1.682 IC 1.237 8.660 27.616 K Factor =5.60 S707 120.0 0.0 1.237 0.0 A 173.3 0.7091 0.0 9.897 7.018 Vel = 25.02 A 0.0 1.682 2T 19.799 0.660 34.634 to 120.0 0.0 19.799 0.290 M701 173.3 0.7090 0.0 20.459 14.505 Vel = 25.02 0.0 173.30 49.429 K Factor= 24.65 ** S708 22.54 1.682 0.0 8.660 16.201 K Factor =5.60 to 120.0 0.0 0.0 0.0 S709 22.54 0.0163 0.0 8.660 0.141 Vel = 3.25 S709 22.64 1.682 1C 1.237 8.660 16.342 K Factor= 5.60 to 120.0 0.0 1.237 0.0 S710 45.18 0.0590 0.0 9.897 0.584 Vel = 6.52 S710 23.04 1.682 0.0 8.660 16.926 K Factor =5.60 to 120.0 0.0 0.0 0.0 S711 68.22 0.1263 0.0 8.660 1.094 Vel= 9.85 S711 23.77 1.682 0.0 8.660 18.020 K Factor =5.60 to 120.0 0.0 0.0 0.0 S712 91.99 0.2196 0.0 8.660 1.902 Vel= 13.28 S712 24.99 1.682 1C 1.237 8.660 19.922 K Factor =5.60 to 120.0 0.0 1.237 0.0 S713 116.98 0.3427 0.0 9.897 3.392 Vel= 16.89 713 27.04 1.682 0.0 8.660 23.314 K Factor =5.60 o 120.0 0.0 0.0 0.0 S714 144.02 0.5035 0.0 8.660 4.360 Vel = 20.80 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Firal Calculations - Hazen-Williams Western Staes Fire Protection Page 6 Westfield Mall Carlsbad Date 4/7/14 Qa Dia. Fitting Pipe Pt Pt Kyd. ef. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn S714 29.46 1.682 1C 1.237 8.660 27.674 K Factor = 5.60 to 120.0 0.0 1.237 0.0 B 173.48 0.7104 0.0 9.897 7.031 Vel = 25.05 B 0.0 1.682 2T 19.799 0.660 34.705 to 120.0 0.0 19.799 0.290 M702 173.48 0.7104 0.0 20.459 14.534 Vel = 25.05 0.0 173.48 49.529 K Factor= 24.65 ** M701 173.30 4.26 0.0 13.000 49.429 to 120.0 0.0 0.0 0.0 M702 173.3 0.0077 0.0 13.000 0.100 Vel = 3.90 M702 173.48 4.26 1C 1.317 13.000 49.529 to 120.0 0.0 1.317 0.0 M703 346.78 0.0277 0.0 14.317 0.397 Vel = 7.81 M703 0.0 4.26 2V 17.907 140.460 49.926 to 120.0 1X 21.067 52.141 0.0 M704 346.78 0.0277 10C 13.167 192.601 5.335 Vel = 7.81 704 90, 0.0 4.26 5C 6.584 78.420 55.261 120.0 IV 8.954 15.538 0.0 M705 346.78 0.0277 0.0 93.958 2.603 Vel = 7.81 M705 0.0 6.357 4V 50.294 198.670 57.864 to 120.0 15C 18.86 69.154 0.217 TOR7 346.78 0.0039 0.0 267.824 1.056 Vel = 3.51 TOR7 0.0 6.357 IT 37.72 13.125 59.137 to 120.0 iBvcb 10.059 95.558 5.818 * Fixed loss = I BOR7 346.78 0.0039 iFsp 0.0 108.683 0.429 Vel= 3.51 is 40.235 6C 7.544 BOR7 0.0 8.249 1 21.141 19.000 65.384 to 120.0 0.0 21.141 0.0 UG1 346.78 0.0011 0.0 40.141 0.044 Vel= 2.08 UG1 0.0 7.98 8E 191.403 98.800 65.428 to 140.0 1G 5.317 243.242 4.834 * Fixed loss = 5.213 TEST 346.78 0.0010 IT 46.522 342.042 0.335 Vel = 2.22 IZaf 0.0 250.00 Qa = 250.00 596.78 70.597 K Factor= 71.03 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I Western Staes Fire Protection 3820 Oceanic Drive Suite 309 Oceanside, Ca 92056 760-439-7558 Job Name : Westfield Mall Carlsbad Building : FP-6.1 Location : CARLSBAD, CA 90067 System : R8 Contract : QT0012 Data File : FP-3rd Level AREA 8 Rev 1 .wxf Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Western Staes Fire Protection Page Westfield Mall Carlsbad Date O HYDRAULIC CALCULATIONS for Project name: WESTFIELD CARLSBAD Location: CARLSBAD, CA 90067 Drawing no: FP-6.1 Date: 3/18/14 Design Remote area number: R8 Remote area location: 3RD FLOOR NORTH Occupancy classification: LIGHT Density: 0.1 - Gpm/SqFt Area of application: 1530 - SqFt Coverage per sprinkler: 225 - SqFt Type of sprinklers calculated: RELIABLE Fl FR56 RECESSED PENDENT No. of sprinklers calculated: 7 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 425.074 -GPM @ 92.729 -Psi Type of system: WET Volume Of dry orpreaction system: N/A - Gal Water supply information Date: 1/27/14 Location: 2525 EL CAMINO REAL Source: WESTERTN STATES FIRE PROTECTION CO. Name of contractor: WESTERN STATES FIRE PROTECTION CO. Address: 3720 INDUSTRY AVE., SUITE 107 LAKEWOOD, CA 90712 Phone number: (562) 279-07 Name of designer: JEFF HOWELL Authority having jurisdiction: CITY OF CARLSBAD Notes: (Include peaking information orgridded systems here.) CALCULATED PER FACTORY MUTUAL Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Sup rsurve (C) • • Western Staes Fire Protection Page 2 Westfield Mall Carlsbad Date City Water Supply: Demand: Cl - Static Pressure : 96.3 Dl - Elevation : 28.404 C2 - Residual Pressure: 82.3 D2 - System Flow : 175.074 02 - Residual Flow : 1272 D2 - System Pressure : 92.729 Hose ( Demand) : 250 D3 - System Demand : 425.074 Safety Margin : 1.728 150 140 130 p120 R° E10° = (- ________________ 90 S 80 U 70 R6° E5° 40 30 20 I I 10 I I 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Usummary 0 Western Staes Fire Protection Page 3 Westfield Mall Carlsbad Date Fitting Legend Abbrev. Name 1/2 % 1 1% 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 Bvcb B Fly Vic 705W 0 0 0 0 0 0 5 5 0 12 12 8 11 12 14 0 0 0 0 0 E NFPA139OStandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 I NFPA139OFlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90' Ell Firelock#001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0 X 90'Tee-BranchFirelock002 0 0 0 0 0 8.5 10.8 13 0 16 21 25 33 0 0 0 0 0 0 0 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Western Staes Fire Protection Page 4 Westfield Mall Carlsbad Date de . Elevation K-Fact Pt Pn Flow Density Area Press Actual Actual Req. S801 65.583 5.6 16.14 na 22.5 0.1 225 7.0 S802 65.583 5.6 16.65 na 22.85 0.1 225 7.0 S803 65.583 5.6 18.49 na 24.08 0.1 225 7.0 S804 65.583 5.6 22.54 na 26.59 0.1 225 7.0 S808 65.583 39.57 na 1801 65.583 42.97 na M801 62.833 46.26 na M802 62.833 46.54 na M803 62.833 49.6 na TOR6 46.833 59.97 na BOR6 14.75 74.99 na M804 14.75 79.22 na RSR1 14.75 81.05 na RSR2 1.625 87.84 na UGI -3.0 89.85 na TEST 0.0 92.73 na 250.0 S805 65.583 5.6 20.95 na 25.63 0.1 225 7.0 S806 65.583 5.6 21.59 na 26.02 0.1 225 7.0 S807 65.583 5.6 23.94 na 27.4 0.1 225 7.0 S809 65.583 37.48 na 1802 65.583 42.34 na The maximum velocity is 18.86 and it occurs in the pipe between nodes S804 and S809 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Staes Fire Protection Page 5 Westfield Mall Carlsbad Date yd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt P1/Ft Eqv. Ln. Total P1 Pn *EQUIVALENT K'S *REMOTE HEAD TO SUPPLY S801 22.50 1.442 0.0 14.670 16.143 K Factor =5.60 to 120.0 0.0 0.0 0.0 S802 22.5 0.0344 0.0 14.670 0.504 Vel = 4.42 S802 22.85 1.442 0.0 14.670 16.647 K Factor =5.60 to 120.0 0.0 0.0 0.0 S803 45.35 0.1256 0.0 14.670 1.843 Vel = 8.91 S803 24.08 1.442 0.0 14.670 18.490 K Factor= 5.60 to 120.0 0.0 0.0 0.0 S804 69.43 0.2763 0.0 14.670 4.053 Vel = 13.64 S804 26.59 1.442 0.0 29.667 22.543 K Factor = 5.60 to 120.0 0.0 0.0 0.0 S809 96.02 0.5033 0.0 29.667 14.932 Vel = 18.86 0.0 96.02 37.475 KFactor= 15.69 S808 79.06 1.682 1 4.95 15.500 39.573 to 120.0 0.0 4.950 0.0 T801 79.06 0.1660 0.0 20.450 3.394 Vel = 11.42 T801 0.0 1.682 IT 9.9 2.750 42.967 to 120.0 0.0 9.900 1.191 M801 79.06 0.1660 0.0 12.650 2.100 Vel= 11.42 M801 0.0 2.635 0.0 15.000 46.258 to 120.0 0.0 0.0 0.0 M802 79.06 0.0187 0.0 15.000 0.280 Vel = 4.65 M802 96.01 2.635 IV 5.903 31.875 46.538 to 120.0 0.0 5.903 0.0 M803 175.07 0.0812 0.0 37.778 3.066 Vel = 10.30 M803 0.0 2.635 3V 17.71 24.667 49.604 to 120.0 0.0 17.710 6.930 TOR6 175.07 0.0812 0.0 42.377 3.440 Vel = 10.30 TOR6 0.0 3.26 1V 6.72 32.083 59.974 to 120.0 0.0 6.720 13.895 BOR6 175.07 0.0288 0.0 38.803 1.117 Vel = 6.73 BOR6 0.0 3.26 2V 13.44 133.583 74.986 to 120.0 0.0 13.440 0.0 M804 175.07 0.0288 0.0 147.023 4.233 Vel = 6.73 M804 0.0 4.26 4V 35.814 198.250 79.219 to 120.0 0.0 35.814 0.0 RSR1 175.07 0.0078 0.0 234.064 1.831 Vel = 3.94 RSRI 0.0 6.357 1X 31.433 11.875 81.050 to 120.0 IBvcb 10.059 81.727 6.684 * Fixed loss WSR2 175.07 0.0011 lFsp 0.0 93.602 0.105 Vel = 1.77 IS 40.235 RSR2 0.0 8.249 1V 15.269 21.000 87.839 to 120.0 0.0 15.269 2.003 UGI 175.07 0.0003 0.0 36.269 0.011 Vel = 1.05 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Staes Fire Protection Page 6 Westfield Mall Carlsbad Date yd. Qa Dia. Fitting Pipe Pt Pt Ref. W "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pt Pn UGI 0.0 7.98 3V 51.838 98.800 89.853 to 140.0 iZaf 0.0 51.838 2.834 * Fixed loss = 4.133 TEST 175.07 0.0003 0.0 150.638 0.042 Vel = 1.12 250.00 Qa = 250.00 425.07 92.729 KFactor= 44.14 *NEW PATH S805 25.63 1.442 0.0 14.670 20.953 K Factor =5.60 to 120.0 0.0 0.0 0.0 S806 25.63 0.0438 0.0 14.670 0.642 Vel = 5.04 S806 26.03 1.442 0.0 14.670 21.595 K Factor =5.60 to 120.0 0.0 0.0 0.0 S807 51.66 0.1599 0.0 14.670 2.345 Vel = 10.15 S807 27.40 1.442 0.0 44.500 23.940 K Factor = 5.60 to 120.0 0.0 0.0 0.0 S808 79.06 0.3513 0.0 44.500 15.633 Vel = 15.53 0.0 79.06 39.573 KFactor= 12.57 S809 96.02 1.682 1E 4.95 15.500 37.475 OT802 120.0 0.0 4.950 0.0 96.02 0.2378 0.0 20.450 4.863 Vel = 13.86 T802 0.0 1.682 1 9.9 2.750 42.338 to 120.0 0.0 9.900 1.191 M802 96.02 0.2379 0.0 12.650 3.009 Vel = 13.86 0.0 96.02 46.538 KFactor= 14.08 S Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 F7L1Copy PRODUCT SUBMITTAL SPECIFICATION SECTION 311313' Part 2 PRODUCTS WESTFIELD CARLSBAD CARLSBAD, CA \3HOIf(P 3Q 6 )9DI vi INSTALLED BY: Western States Fire Protection, Inc. 3720 Industry Avenue Suite 107 Lakewood, CA 90712 Phone: 562.279.0770 Fax: 562.279.0775 Western States Fire Protection Co. oted 4eeie4 4d fret a subsidiary of API GROUp, Inc. ( As\4oR \ Carlsbad Municipal Water District Potable Water Discharge Event Report Date: LTJ Location: 25_LA MIL7L_. Reason for Discharge Event: Type of Event Initial Dewatering Water Mains -Al A. Estimated Discharge Flow: ---- GPM Note: Includes flow testing and flushing Dewatering Water Mains Start Time EL Unscheduled Water Discharge Clear flow path of debris, surface contaminants and/or hazardous materials. Do not remove native vegetation. Erosion control, i.e. sandbags, silt fencing, hay bales, gravel bags, decreasing the velocity of discharged water. 4 131 Endl]me ------- Pre-Dechlorination' Residual: aL.3I8 Post-Dechlorination Residual: 21P (Less than 0.1 mg/L) PH within limits of 6.0 and 9.0 -. Upon completion of dewatering, ensure that the flow path is free of all temporary erosion prevention materials. Upon completion of dewatering, ensure that any sediments or silted areas are cleared. Water Sampling Performed by: Comments: Submitted by: Reviewed by: (Name & Date) (Name & Date) Flow Test Record Test Hydrant Location 2525 El Camino Real Hydrant ID No. Size Main 10 Static ............... 107 Residual ... .........93 Pressure Drop, 14 (PD! .1)..... K .factoi for PDI 1 4 .16 Flow Hydrant(s) Uydraiitl location Gauge HYD @ 24hr Fintness Hydrant2 location Flow HYD @ JC Penny's Hydrant 3 location___________________________________________________ Hydrant I Pitot PSI GPM: Size of Orifice_________ Hydrant 2 Pitot 73 PSI GPM: 1272 Siz. of Or, 2 5 Hydrant 3 Pitot PSI GPM; Size of Orifice_________ Total: 1272 O (Qi) Calculated test and flow, data - 9 xPD2k =Q2 P1)1 k Static: .................... 107 Desired Residual 2G Pressure Drop (PD 2).. 87 .. .. ....................... K factor PD,2: 11 .15 1272 x 11.15 dividedby 4.16 equals 3,409 _GPM at20 psi residual Qi PD2K PD1k Q Comments: Test conducted for WestfieldMallRenovation -Firesprinklerflowtest Conducted by:JeremiahBalchandJimmyGrindelofWestern States Fire Protection Date: 1/27/14 Time: 73° . Flow Test: Record Formulas GPM-Flow 2W' 4" 1 170 16 670 1 430 16 1720 2 240 17 690 2 610 17 1770 3 290 18 710 3 740 18 1820 4 340 19 730 4 860 19 1870 5 380 20 750 S 960 20 1920 6 410 22 790 6 1050 22 2020 7 440 24 820 7 1140 24 2110 8 480 26 860 8 1,220 26 2190 9 500 28 890 9 1290 28 2280 10 530 30 920 10 1,360 30 2330 II 560 33 950 11 1430 32 2430 12 580 34 980 12 1490 34 2510 13 610 36 1010 13 1550 36 2580 14 630 38 1040 14 1610 38 2650 15 650 40 1060 15 1660 40 2720 K Factor Formula PD K PT) K PD K PD K PD K 1= 10 21= 518 41= 743 61= 921 81= 1073 2= 145 22= 53! 42= 753 62= 929 82= 1080 3= 181 23= 544 43= 762 63= 917 83= 1087 4= 2.1 1 24= 556 44= 7.72 64= '9.4 5 84= 10 94 5= 239 25= 569 45= 781 65= 953 85= 1101 6= 2.63 26= 5.81 46= 7.91 66= 0.61 86= 11,08 7= 2.86 27= 5.93 47= 8.00 67= 9.69 87= 1115 8= 307 28= 605 48= 809 68= 976 88= 1122 9= 328 29= 6.16 49= 8,18 69= 9.84 89= 11 .29 10= 347 30= 628 50= 8.127 70= 992 90= 1136 11= 365 31= 639 51= 836 71= 999 91= 1143 12= 3.8.3 32= 6.50 52= 8A 72= 10.07 92= 11.49 13= 400 33= 661 53= 853 73= 1014 93= 1156 14= 4.16 34= 671 54= 8.64 74= 1022 94= 11.63 15= 432 35= 6.912 55= 871 75= 1029 95= 1169 16= 4.48 36= 693 56= 8.79 76= 1037 96= II 76 17= 472 37= 703 57= 888 77= 1044 97= 1183 18= 476 38= 713 58=1 896 78= 1051 98= 1189 19= 4.90 39= 7.23 59= 9.04 79= 10.59 99= 11.96 20= 5,04 40= 7.33 60= 9.12 80= 10.66 100= 12.02 *MJ. Pressure drop K = K factor S FIRE & WATERWORKS ES-A-3000SS / Series 300OSS Double Check'Detector Assemblies // ?y - y Sizes: 21/2 - 12",65 — 300mm) / / Li \}. Features . .. Cam-Check Assembly valve provides Irn*, hnarl Ir,c.c. /Short lay length is ideally suited for'\\ 7, / retrofit installations Stainless Steel body is half the weight / of competitive designs reducing / \ \ \ / installation and shipping cost Stainless steel costruction provides - / long term corrosion protection and Sertes 3000SS Double Check DetectorAssemblies are desigfled for use in accordance with water utility non-health hazard containment requirements. It is mandatory to prevent the Single to 11 p access -11 cover with two-bolt grooved style coupling for ease of and water of non-potable quality from being pumped or siphoned into the potable water maintenance supply. No special tools required for servicing Compact construction allows for smaller vaults and enclosures S . Furnished with % x 3/4"bronze meter (gpm or cfm) Detects underground leaks and unauthorized water use Maybe installed horizontal or vertical "flow up" position Available Models Suffix: LG - less shutoff valves OSY - UL/FM outside stem and yoke resilient seated gate valves OSY FxG — flanged inlet gate connection and grooved outlet gate connection OSY GxF — grooved inlet gate connection and flanged outlet gate connec- tion OSY GxG - grooved inlet gate connection and grooved outlet gate connection CFM - cubic feet per minute GPM - gallons per minute meter Post indicator plate and operating nut available - consult factory Job Name Job Location . Engineer Approval Specifications A Double Check Detector Assembly shall be installed on fire protection systems when con- nected to a potable watersupply. Degreeof hazard present is determined bythe local author- ity having jurisdiction. The main valve body shall be manufactured from 300 Series stainless steel to provide corrosion resistance, 100% lead free through the water- way. The double check detector assembly consists of two independently operating, spring loaded check valves, two UL. FM, OSYresilientseatedgatevalves, and bypass assembly.The bypass assembly consists of a meter (cubic ft. or gallons), a double check including shutoff valvesand required test cocks. Each cam -check shall be internally loadedand provideaposi- tive driptight closure against reverseflow. Cam-check includes a stainlesssteel cam armand spring, rubberfaced discand a replaceable seat. There shall be no brass or bronze parts used with in the cam -check valve assembly. The checkvalve seats shall beof molded thermoplastic construction. The use of seat screws as a retention method is prohibited. All internal parts shall beaccessiblethrough asinglecoveronthevalveassembly.Thevalvecovershall be held in place through the use of a single grooved style two-bolt coupling. The bypass line shall be hydraulically sized to accurately measure lowflow. The bypass line shall consistof a meter, a small diameter double check assembly with test cocks and isolation valves. The bypass line double check valve shall have two independently operating modular poppet check valves, and top mounted test cocks. The assembly shall be an Ames 3000SS. Materials All internal metal parts: 300 Series stainless steel, Main valve body: 300 Series stainless steel, Check assembly: Noryl® Flange dimension in accordance with AWWA Class D. Noryl® is a registered trademark of General Electric Company. Contractor Approval Contractor's P.O. No. Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com I I A Pressure - Temperature Temperature Range: 33°F - 110°F (0.5°C - 43°C) Maximum Working Pressure: 175ps1 (12 bar) OCapacity Flow curves astested by Underwriters Laboratory perU L 1469,1996. * Rated flow **UL Tested * ** kPa psi 21/211 (65mm) ________u._.I____ a__u u• ____. iP !•• M_ omml 161' u on 1 .1 LIII1T7ITh I.......... .R... NEENEENEENEENEW i•......... ..-r4 MONEEMENNE WEEM 1, Standards ASSE 1048, AWWA C510-92, CSA 1364.5, UL 1469 Approvals UL Classified (OSY only), FM (sizes 21/2 - 10, OSY only) FM (9 <15> UL Aproved 9 CPa psi 611 (150mm) ** 103 15 83 12 62 41 6 21 3 8 100 200 300 409 500 600 700 800 900 1000 1100 1200 1300 1400 1500 gpm 380 760 1140 1520 1000 2280 2660 3040 3420 3909 4180 4560 4940 5320 5700 1pm 5 10 15 fps 1.5 3 4.6 mps CPa psi 8" (200mm) ** 03 12 - 62 9 - - - - -- 21 ::ii 0 2000 2250 2500 gpm 250 500 750 1009 1250 1500 1750 950 1900 2850 3800 4750 5700 6650 7600 8550 9500 1pm 5 10 15 fps 1.5 3 4.6 mps 10" (250mm) * ** CPa psi 103 15 83 12 62 0 416 21 3 - - - - - - - 0 250 500 750 1080 1250 1500 1750 2009 2250 2586 3000 3590 gpm 950 1900 2850 3060 4750 5700 6650 7600 8550 9500 11400 13300 1pm 5 10 Ips 1.5 3 mps I -------- ------ CPa 83 69 55 41 29 14 CPa 103 83 62 SIZE (ON)IsJI0l4091[I12k NET WEIGHT NET WEIGHT in. ann in, A mm in. C (0S'i) mm in, D mm G in. mm I in. mm P M. mm wiGates lb. kg. w/o Gates lb. kg. 21/2 65 37 965 16/o 416 31/2 89 10 250 22 559 121/2 318 155 70 68 31 3 80 38 965 18/8 479 33/4 95 10 250 22 559 13 330 230 104 70 32 4 100 40 1016 22/4 578 41/2 114 10 250 22 559 141/2 368 240 109 73 33 6 150 481/2 1232 301/s 765 51/2 140 15 381 271/2 699 151/2 394 390 177 120 54 8 200 521/2 1334 373/4 959 6/4 171 15 381 291/2 749 181/2 464 572 259 180 82 10 250 1 551/2 1410 453/4 1162 1 8 200 1 15 381 1 291/2 749 191/2 495 1 774 351 190 86 12 300 1 571/2 1461 531/8 1349 1 91/3 241 1 15 381 1 291/2 749 21 533 1 1044 474 1 220 100 PAM.ES 9M919001-20081 FJR&WATRWORKS www.amesfirewater.com cmr IFI ED A Watts Water Technologies Company USA: Backflow- Sacramento, CA • Tel, (916) 928-0123 • Fax (916) 928-9333 Control Valves- Houston. TX • Tel. (713) 943-0688 • Fax (713) 944-9445 Canada: Burlington. ON • Tel, (905) 332-4090 • Fax (905) 332-7068 ES-A-3000SS 1114 © 2011 Ames Fire & Waterworks l(U Western States I Fire Protection Co. ot€th9 44*cfte S e zubsidier, of API cow^ flC. MATERIAL INDEX Paragraph I 2.2 STEEL PIPE AND FITTINS ALLIED TUBE & CONDUIT WHEATLAND PIPE BULLMOOSE TUBE COMPANY 2.3 PIPING JOINING MATERIALS STAR PIPE PRODUCTS VICTAULIC GROOVED FITTINGS I 2.4 LISTED FIRE PROTECTION VALVES TOLCO UG CLAMP FIG 9 TOLCO TIE BOLT FIG 106 SIGMA C110 FITTINGS TYLER C110 FITTINGS BLUE BRUTE C900 PIPE UG MEGA LUB SERIES 15MJOOTD UG MEGA LUB SERIES 1100 MJ RESTRANT FOR DI PIPE GRIFFEN PIPE PRODCTS CO. DI PIPE CLASS 51-53 . UG NIBCO INDICATOR POSTS UG NIBCO IRON DODY GAE VALVES VICTAULIC BUTERFLY VAVLE NIBCO WAFER CHECK VALVES VICATULIC CHECK VALVES 2.5 TRIM AND DRAIN VALVES 2.6 FIRE DRPARTMENT CON NCETIONS POTTER ROEMER MODEL 5715-A-DI 2.7 SPRINKLER SPECIALTY PIPE FITTINGS VICTAULIC OUTLET-I VICTAULIC ZONE CONTRLO RISER MODULE VICTRALIC Vic Flex SPRINKLR FITTINGS 2.8 SPRINKLERS I RELIABLE SPRINKLER HEADS 2.9 ALARM DEVICES I SYSTEM SENSOR ALARM BELL SYSTEM SENSOR WFD SEREIES WATERFLOW DETECTOR SYSTEM SENSOR PIBVS SUPERISORY SWITCH 2.1 MAUNUAL CONTROL STATIONS I NOT USED 2.11 PRSSURE GAGES I RELIABLE GAGES 1 of 2 1I(3 Western States Fire Protection Co. oteetia 44'e 4rd ftet a subsidiary of as CrOW, 1nc4 MATERIAL INDEX Paragraph HANGERS AND SWAY BRACING MTRLS. TOLCO FIG. ZSTR STD PIPE STRAP TOLCO FIG. 4 STD PIPE CLAMP TOLCO FIG. 41 LONGITUDINAL SWAY BRACE ATTACHMENT TOLCO FIG. 6 STD RISER CLAMP TOLCO FIG. 58 SIDE BEAM BRACKET TOLCO FIG. 69 RETAINER STRAP TOLCO FIG. 75 SWIVEL ATTACHMENT TOLCO FIG. 200 ADJ BAND HANGER TOLCO FIG. 825 BAR JOIST SWAY BRACE ATTACHMENT TOLCO FIG. 828 UNIVERSAL SWAY BRACE ATTACHMENT TOLCO FIG. 980 UNIVERSAL SWIVEL SWAY BRACE ATTACHMENT TOLCO FIG. 1000 FAST CLAMP TOLCO FIG. 1001 SWAY BRACE ATTACHMENT TOLCO FIG. 65X1-3/8" BEAM CLAMP TOLCO FIG. 68 WIDE JAW REV C-CLAMP TOLCO FIG. 68S C-CLAMPS TOLCO FIG. 113 & 114 NUTS & WASHERS S TOLCO FIG. 70 & 71 ROD COUPLINGS TOLCO FIG. 110 U-BLOTS fl 2 of 2 SPECIFICATION SECTION 2.11 R bl M \C çlel C - Automatic Ball Drip An aomatic drain valve horizontally installed at the low point in the fi?department connection piping of automatic sprinkler systems .'V/ater pressure from a fire department pumper au- tomaticallyoses this valve. It automatically re—opens when pressure ceas, permitting this piping to drain and thereby preventing freeg. Made of bronze and available with 3/4" (R3/4 ) or 1/2" NPT (/2) female inlet connection. FM approved. Length: 2/16". Maxium working pressure: 175psi (12bar). Model C - Mechani\al Ball Drip Valve The Model C Mechanical'll Drip Valve is a listed trim com- ponent used in the alarm li'hç of Reliable Model A & D dry valves, Model DDX deluge a DDX preaction valves. The mechanical ball drip valve is dened to close upon activa- tion of the dry or deluge valve w sufficient flow is pres- ent in the alarm line. In the normal o\open position the me- chanical ball drip allows for the relievi)s of pressure in the alarm chamber of the valve. After valve acti,yation, push in the plunger of the mechanical ball drip valve toanuaIly release the water pressure and to drain the alarm Ii of the valve. Made of bronze and available with ½" NPT (R1/2 female inlet connection. FM approved. Length: 31/2". Maximu'l working pressure: 175 psi (12 bar). Model C - 2" (50 mm) Sight Drain Designed for installation in drain lines of sprinkler syste S that connect with closed drains. Made of cast iron with ea plastic tube. Has 2" NPT (50mm) female pipe conne on. Length: 6" (152mm). Model B - Drum Drip / Permits draining the low points of dry pi systems without tripping the system. Made of cast iron h 3/4" NPT (R3¼) fe- male pipe connection at each end. / Diameter: 61/2" (165mm). Length: 7,/" (197mm). Model A - Control VaVe Seal Made of tin—plated steel. i/o piece, snap type construction. Outer piece holes are Øed for use with standard sealing wire (wire not includeç Diameter: /" (22m. Mod/A—ill Cup Made n. Available with 1/2" or 3/4" NPT (R1/2 or R3/4) femal nection. Cup D 3/4" (95mm). Length: 21/4" (57mm). Bulletin 206 Rev. 0 Ball Drip C Sight Drain CD Drum Drip Control Valve Seal 0 Fill Cup 0) Inspectors Test Connections (2 Pressure Gauges The Reliable Automatic Sprinkler Co.., Inc., 103 Fairview Park Drive, Elmsford, New York 10 SPECIFICATION SECTION 2.11 Inspectors Test Connections Installed in the test line of sprinkler systems to test alarms by simulating the flow of water through a spnk ModeI A - Blind Test Connection DesignedHallation in test lines of sprinkler systems that . connect to open Made of bronze with 1" NF female pipe connections. Orifice s flow equivalent to one nomi- nal 1/2' (15mm) orifice sprinkler. . . Length: 17a" (48mm). Maximum working pressure: 175psi (l2bar). Model B - Sight Test Cojuie6tion Designed for installation on -dfin side of the test valve in a test line that connecWiclosed drain. Made of cast irojj..witcIear tube. Smoothbore non-corrosive orifice giv -ow equivalent to one nominal 1/2" (15mm) orifice spDlf Has 1" NPT pipe connections. ngth: 51/16" (129mm). 10 Model UA - Water Pressure Gauge Range 0 to 300psi in 5psi increments, and 0 to 2000 kPa in 50kPa increments. 1/4" NPT (R1/4) male pipe connection. Case: 31/2" diameter (89mm). Height: 43/4" (121 mm). Also available (not shown) with a range of 0 to 600psi (4000kPa) with lOpsi (100kPa) increments. Accuracy: ANSI 1340.1 Grade B (3-2-3%) Underwriters Laboratories Listed, WI KA Instrument Model 111.10, UL Listed file EX5232 Factory Mutual Approved 1VIo4eI UA - Air Pressure Gauge Range 0-Q2si in 1psi increments, and 0 to 550kPa in lOkPa increments to 250p5i and 1750kPa. 1/4" NPT (R74) male pipe connec . Case: 31/2" diameter (89mm). Height: 43/4" (121mm). Accuracy: ANSI B40.1 Grade B (3-2-3%) Underwriters Laboratories Listed, WIKA Ii Model 111. 10, UL Listed file EX5232 Factory Mutual Approved Low Air Pressure pjapfiragm Gauge Range 0 to 60 oz. in z. increments, and 1/4" NPT (A 1/4) male pipe co on. Case: 1/2" diameter (63.5mm). Height: 31/2" (88.tY. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the united States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Recycled ® (800) 431-1588 Sales Offices Paper Reliabl (914) 829-2042 Corporate Offices e (800) 848-6051 Sales Fax Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 10/13 P/N 9999970037 I[cT;TWtN(:1:TX.1 Fig. 1000 - "Fast Clamp" Sway Brace Attachment 10 Size Range: Pipe size to be braced: 1(25mm) thru 4" (1 00mm) 40 IPS.* Pipe size used for bracing: 1 '(25mm) and 11/4" (32mm) Schedule 40 IPS. * Maximum horizontal design load is 655 lbs. (2.91kN) Torque requirement is 6-8 ft./lbs. (8-10Nm). For pipe sizes larger than 4" (100mm) please refer to TOLCO Fig. 1001. Material: Steel APPOVtD Function: For bracing pipe against sway and seismic disturbance. Features: Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation: Fig. 1000 is the 'braced pipe attachment component of a lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and Cooper B-Line/TOLCO structural attachment component, Fig. 980 or other approved TOLCO seismic brace to form a complete bracing assembly. Follow NFPA 13 guidelines. To Install: Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is recommended that the brace angle be adjusted before hex nuts are fully tightened. Approvals: Approved by Factory Mutual Engineering (FM). For UL Listed information refer to page 62. Application Note: Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Is Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1" (25mm) or 11/4" (32mm)) , and finish. Designed to meet or exceed requirements of FM DS 2-8. Pipe Part Number & Approx. Wt./100 Design Size 1" (24mm) Brace Pipe 11/4" (32mm) Brace Pipe Load . 1 (25) 1000-1 X 71 6 (325) 1000- 1 X 1114 ' 758. 400 (1.78) 11/4 (32) 1000.11/4 X 1 748 (339) 1000 11/4 X 1114 79.1 (5 9) 82.11I7.2) 400 400 (1,78) (1.78) 11/2' (40) 1000-1112X 1 77.8 (35.3) 1000.11/2 X11/4 2" (50) 1000-2X 1 84.1 (38.1) 1000-2X 1114 88.4 (40,1) 400 (1.78) M"(8 1000 21k X 1 1000-3 XI 902 (409) 1000 21/2 X 11/4 1000-3 X 11/4 1000.31/2 X 111 400 (178) 1 973 (441) 101.7 (461) 108.4j (49.2) 466 466 (2.07) (2.07) 31/2" (90) 1000.31/2 X I 104.0'fi) 4" (100) 1000-4X1 1 110.31 —(50.0),10004X11/4 114.6 ,(520) 466 (2.07) FM Approved design loads are based on ASD design method. * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? is the installation angle measured from the vertical. Hardware Included Cooper B-Line, Inc.'s ('Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be . the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line x ii APPROVED FM Approved Design Loads * 21/2" (65mm) pipe size - 1600 lbs. (7.11kN) 3" (75mm) to 4" (100mm) pipe size - 1700 lbs. (7.56kN) 5" (125mm) to 8" (200mm) pipe size - 1033 lbs. (4.59kN) ** See load ratings in FM Approved Design Load chart. * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where? is the installation angle measured from the vertical. FM Approved design loads are based on ASD design method. Fig. 1001 - Sway Brace Attachment Size Range: Pipe size to be braced: 21/2" (65mm) thru 8' (200mm) IPS. * Pipe size used for bracing: 1(25mm) and 11/4" (32mm) Schedule 40 IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1" (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Approved by Factory Mutual Engineering (FM). For UL Listed information refer to page 64. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1" (25mm) or 11/4" (32mm)) , and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the FM Approval requires that Fig. 1001 must be used only with other Cooper B-Line/TOLCO bracing products. Designed to meet or exceed requirements of FM DS 2-8. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 200-/2. 200-I4 Fig. 200_2112 to 200-8 Fig. 200-1 to 200-2 HANGERS & SWAY BRACING Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) C@ us W Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B317ONFC) URED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-11 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements o FM DS 2-0. Fig. 200 S TW'. 200_1Iz Pipe Size 1/2 (15) Rod Size /8 -16 A II 31/8" (79.4) B "T 2/8 (66.7) Approx. 11 !/ II (5.0) 200-I4 3/4" (20) /a"-16 31/g" (79.4) 21/2" (63.5) ii (5.0) 200-1 200_11/4 200.11/2 11. 11/4" 11/2" (25) (32) (40) /8°-16 /'-16 /8'-16 3 /8° (85.7) 2/" (66.7) 12 (5.5) 33/4" 3/" (94.0) (98.4) 2/&' (73.0) 2/" (73.0) 13 14 (5.9) (6.4) 2002 2 (50) 3/8"-16 41/2 (1143) (142.9) 3 41/8 (763) (104.7) 15 27 (69) 200.2112 21/2 (65) /8'-16 5/8 (12.3) 200-3 200.31/2 3" 31/2" (75) (90) /8-16 /8'-16 57/g° 7 /8" (149.1) (187.3) 4" 51/4" (101$) (133.3) 29 34 (13.3) (15.6) 200-4 200-5 4" 5' 1 (100) (125) /-16 1/2 .13 7I8" 91/8" (187.3) (231.8) 5" 61/4' (127.0) (158.7) 35 66 (16.0) (30.2) 200-6 6" (150) 1/2"_13 101/8" (257.2) 6I4" 8/4" (171.4) (222.2) 73 136 (33.4) (62.3) 200-8 8" (200) 1/2"_13 131/8 (333.4) Fig. 200S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PP_ 00 COOPER B-Line I* S Fig. B2400 - Standard Pipe Strap (TOLCO Fig. 2STR) Size Range: 1/2" (15mm) thru 24 (600mm) pipe Material: Steel Function: Designed for supporting pipe runs from strut supports. Approvals: Underwriters Laboratories Listed for 132400-3/4' thru B2400-8". Conforms to Federal Specification WW-H-1 71 E & A-A-1 192A, Type 26 and Manufacturers Standardization Society ANSI/MSS Design SP-69 & SP-58, Type 26. Load 3 Finish: Electro-Galvanized. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish r Note: Ductile iron sizes available. Special "B" dimensions available on request, consult factory. Pipe Size Design Load 1 Design Load 2 B2400-112 1/2" (15) /16" (7.9) /i" (11.1) I'. 213/16" (71.4) 10 Ga. (3.4) 1/8" (41.3) B2400-3/4 3/4" (20) /16' (79) 7hC (11 1) 3 (762) 10 Ga (34) 1 /a (413) B2400-1 (25) /i" (7.9) /16" (11.1) 317/32" (89.7) 10 Ga. (3.4) 1/8" (41.3) B2400-11/6 11/4 (32) /16' (79) /16 (11 1) 33/4 (952) 10 Ga (34) i/o (41 3) 82400-11/2 11/2" (40) /i" (7.9) /16" (111) 41/16" (103.2) 10 Ga. (3.4) 1/8" (41.3) B2400-2 (50) /i" (11.1) 11/16" (17.4) 521/32" (1436) 3/4" (6.3) 1/" (41.3) 82400_21/2 21/2" (65) /16" (11.1) 11/16" (17.4) 6/32" (156.3) 1/4" (63) 1I8" (41.3) 82400-3 (80) /16" (11,1) 11/6" (17.4) 625/32" (172.2) 1/4" (63) 1/8" (41.3) B2400-3112 31/2" (90) I16" (11. 1) 11/16" (17.4) 7/32" (184.9) 1/4" (6.3) 1/8" (41.3) B2400-4 (100) /16" (14.3) 11/16" (17.4) 725/32" (197.6) 1/4" (6.3) 1I8" (413) B2400-5 (125) /16" (143) 11/16" (17.4) 8/8" (225.4) 1/4" (63) 1/" (41.3) B2400-6 6 (150) /16 (143) 11/16 (174) 915/16 (2524) 1/4 (63) 1/a' (413) 82400-8 8" (200) /16" (14.3) 11/16" (17.4) 1131/32" (304.0) 1/4" (6.3) 15/8" (41.3) Part No. B2400-112 Design 600 Load 1 (2.67) Design lLoad ' 150 TL (.67) ' 105 (47) ' 23 (10.4) B2400-I4 600 (2.67) 150 (67) 105 (47) 26 (11.8) B2400-1 600 (2.67) 150 (67) 120 (53) 31 (14.0) B2400-11/4 600 (2.67) 150 (.67) 120 (53) 36 (16.3) B2400-11/2 600 (2.67) 150 (.67) 120 (.53) 39 (17.7) 82400-2 82400_21/2 1200 1200 (5.34) (5.34) 480 480 (2.14) (2.14) 180 180 (.80) (.80) 93 106 (42.2) (48.1) B2400-3 1200 (5.34) 480 (2.14) 300 (1.33) 132 (59.9) B2400-3/2 1200 (5.34) 480 (2.14) 300 (1.33) 151 (68.5) B2400-4 1500 (6.67) 600 (2.67) 450 (2.00) 160 (72.6) 82400-5 1500 (6.67) 600 (2.67) 450 (2.00) 192 (87.1) B2400.6 1500 (6 67) 600 (267) 450 (200) 219 (993) 82400-8 2000 (8.90) 800 (3.56) 600 (2.67) . 297 (134.7) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. pp- 00 COOPER B-Line For larger sizes, consult the full line pipe hanger catalog. i: T.11 111rciiii CING B3140 - Standard Pipe Clamp (TOLCO Fig. 4) B3140C - Standard Pipe Clamp PVC Coated (FOLCO Fig. 4PVC) Size Range: 133140/133140C Size 1/2° (15mm) thru 30" (750mm) pipe. Material: Steel Function: Recommended for the suspension of non-insulated pipe or insulated pipe with B3151 shields. (Use B3200 weldless eye nut, B3210 eye rod or B3211 welded eye rod.) Also recommended for attachment of sway bracing up to 31/2" (90mm) pipe size, for larger pipe sizes use Fig. 4A. 831 40F and B3140C are designed to reduce noise and vibration and/or prevent electrolysis. Approvals: Underwriters Laboratories Listed in the USA (UL), Canada (cUL) 3/4" (20mm) - 12' (300mm), and approved by Factory Mutual Engineering (FM), 3/4' (20mm) - 8' (200mm). Federal Specification WW-H-1 71 E & A-A-1 192A, Type 4, and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 4. Note: When the B3140 is used as a sway brace, to ensure performance, the UL Listing requires that it must be used with other Cooper B-Line/TOLCO brace products. Maximum Temperature: - 750°F (399°C) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. Order Note: When ordering B3140F allow for /16" (4.8mm) felt on each half of clamp. Designed to meet or exceed requirements of FM DS 2-0. Bolt Size I B B3140 83140C L n All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PP_ 00 COOPER B-Line ]•] 1_.*I <~> 0 APPROVED 5,4 Roll & Hardware Ineludod 4-Way Riser Brace (plan view) HANGERS & SWAY BRACING Fig. 4L - Longitudinal "In-Line" Sway Brace Attachment Size Range: 21/2" (65mm) through 8" (200mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Approved by Factory Mutual Engineering (FM), 21/2" (65mm) through 8" (200mm) pipe. For UL Listed information refer to page 46. Installation Instructions: Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and Cooper B-Line/TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or FM guidelines should be followed. To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. Designed to meet or exceed requirements of FM DS 2-8. Longitudinal Brace FM Approved when used with 1", 11/4", 11/2' or 2" Sch. 40 brace pipe. FM Approved design loads are based on ASD design method. Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper 13-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line HANGERS & SWAY BRACIN Fig. 58 - Threaded Side Beam Bracket Size Range: /8"-16 rod, pipe sizes 1/2° (15mm) thru 4" (100mm) Material: Pro-Galvanized Steel Function: Practical and economical bracket used to support piping from wood, con- crete or steel beams. Features: Uniquedesign allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept and 1/2" fastener bolts. Per NFPA 13: 1/2° (15mm) thru 2" (50mm) pipe requires /8" fastener, 21/2 (65mm) thru 4" (100mm) pipe requires 1/2° fastener.* Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4" (100mm) pipe. Finish: Pro-Galvanized Order By: Figure number and finish *Note: Additionally UL has listed the Fig. 58 with fasteners as shown in table below. 2 - 1/4 x 2° Lag Bolts (No Pre-Drilling Up to 4' (100mm) pipe C Per NFPA 1 - or 1/2 Lag Bolts Up to 4 (100mm) pipe 2-#16x2 Drive Screws 1/2 (15mm) -4' (100mm) pipe UL Listed Fastener Table Pipe Size I Oty Fastener Type Material 2" 2 #16 x 2 Drive screws Wood 2" 1 3/8" Lag bolt Wood 21/2 - 4" 1 1/2" Lag bolt Wood 31/2 - 2 1/4" It 11/2' Lag bolts Wood 4" 2 1/4" x 2" Lag bolts ** Wood 4" 2 1/4" x 1" Tek screws Metal (15 gauge) 4" 2 1/4" xl" Tek screws Metal (16 gauge) ** No pre-drilling Larger pipe sizes can be hung with reduced spacing. 2- #14x 1" Tek Type Screws Into Mm. 16 Gauge Steel Up to 4' (100mm) pipe Bolt & Hex Nut Up to 4" (100mm) pipe All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PP_ 00 COOPER B-Line HANGERS & SWAY BRACING Fig. B3373 - Standard Riser Clamp (TOLCO Fig. 6) Fig. 83373C - PVC Coated Standard Riser Clamp (TOLCO Fig. 6PVC) Size Range: (B3373) 1/2" (15mm) thru 30° (760mm) pipe (B3373C) 1/2° (15mm) thru 6' (150mm) pipe Material: Steel Function: Used for supporting vertical piping. Approvals: Underwriters Laboratories Listed in the USA (UL), Canada (cUL) 3/4' (20mm) - 8' (200mm). Factory Mutual Engineering Approved, 3/4" (20mm) thru 8" (200mm). Conforms to Federal Specification WW-H-1 71 E & A-A-1 192A, Type 8, and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 8. Maximum Temperature: 650°F (343°C) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. Designed to meet or exceed requirements of FM DS 2-0. ®TOUXT $@tls LWO Design Load Bolt Size Bolts and Nuts Included Part No. .___l..___iiin. B3373-112 Pipe Size lLhfl_.r.._ (15) in. 9" L (228.6) 3/s"-16x11/4 ' Approx. Wt./100 .P. 101(45.9) B3373-/4 83373-1 B3313-1I4 3/4" (20) 1" (25) 11/4 ' (32) 91/4" 9/16" 10" 1(234.9) (242.9) (254.0) 3/s"-16x11/4° 3/s"-16x11/4 ' 3/6"16X11/4" 105 (47.7) 109 (49.4) 11331311/2 11/2' (40) 101/4" (260.3) /8'-16 xi 1 /2' 113 (51.1) 83373-2 83373-21h (50) 10/4" (273.0) 3/8"-16X 11/2" 165 (75,0) 21/2 (65) 111/4" (285.7) /t"-i 6 xi 1/2" 180 (16) 83373-3 (80) 1115/16" (36. 2) 3/8"-16Xi1/2" 195 (88.4) B3373-31k 31/2" (90) 12I8" (314.3) 112"-13X 1/4" 217 (98.5) B3373-4 (100) 12/t" (327M) 1/2"-13X13/4" 228 (103.5) 83373-5 (125) 14' (355.6) 1/2"-13x13/4 ' 480 (217.7) 83373-6 (150) 15I16' (385.8) V2"-13X2" 526 (238.6) B3373-8 83373-10 8" (200) 17/4' (450.8) /8"-11 X21/2" 957 (434.1) 10" (250) 19I1" (493.7) /3'1i x2112' 1101 (499.4) 83373-12 8337314 12" (300) 2111/16 (550.9) /8"-11 x3' -11 x3 1622,j (735.7 732 56 Notes: For ductile iron (Dl.) pipe use part number B3373C1-pipe size. Contact B-Line Engineering for more information. For larger sizes, consult the full line pipe hanger catalog. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. pp- 00 COOPER B-Line HANGERS & SWAY BRACING Fig. 69 - Beam Clamp Retaining Strap (Cooper B-Line B3367) Size Range: /8-16 thru /4-10 rod 4" (1 01 .6mm) thru 16" (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind, such as a hex for the Fig. 69 will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Finish: Pre-Galvanized Order By: Figure number, length (L), and finish. Note: Minimum return on strap is 1" (25.4mm) For Use With: Any Cooper B-Line or TOLCO beam clamp. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified, p.-.- cOOPER. 8-Line i•i '_.I* I0h1E_i ILl I ' GERS & SWAY BRACING Fig. 75 - Swivel Attachment Size Range: - I8-16 Rod Attachment Material: Steel Function: Three recommended applications for this product: May be used as a Branch Line Restraint for structural attachment to anchor bolt, beam clamp, etc. May be used in a pitched or sloped roof application, to meet requirements of NFPA 13 (2010) 9.1.2.6. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support up to 4' (1 00mm) pipe. Finish: Electro-Galvanized Weight: Approx. Wt./100 - 13.3 Lbs. (6.0kg) Order By: Figure number Patent: #7,887,248 -------------------- C Fig. 78 All Steel Coiling Plate Fig. 75 Swivel ig"8 All Steel Coiling Attachment Li Adjustable 8 Fig. 200 and :r Plate / Fig. 25 Surge Restrainer May be used as a structural attachment component of a branch line restraint Fig. 65X1 Reversible Beam Clamp W-Beam '.- Fig. 75 Swivel Attachment - All Threaded Rod May be used with a pitched roof application, to meet requirements of NFPA 13 (2010) Sec. 9.1.2.5. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. pp— 00 COOPER B-Line Set Bolts & Hardware Included (9.5) HANGERS & SWAY BRACING 1rsi i:*i <€> APPROVED Fig. 825 - Bar Joist Sway Brace Attachment Size Range: One size accommodates all Fig. 900 Series sway brace attachments. Material: Steel Function: To attach sway bracing and hanger assemblies r to steel members. 'i - MW k Features: This product's design incorporates a concentric 1 attachment point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and . fasteners. Permits secure non-friction connection without drilling or welding. Unique design reinforces point of ------------------- - connection to joist. Break off head set bolt design assures verification of proper installation torque (mm. 31 ft.-lbs.). Approvals: Approved by Factory Mutual Engineering (FM). For UL Listed information refer to page 50. Installation Instructions: Fig. 825 is the structural attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, 'bracing pipe" and a Cooper B-Line/TOLCO "braced pipe" attachment, to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 825 on the steel beam, tighten the cone point set bolts I FM Approved Design Loads* until heads break off. Attach other Cooper B-Line/TOLCO transitional attachment 1933 lbs. (8.60kN) - Across Beam fitting, Fig. 980, 910, 909, or any other Cooper B-Line/TOLCO approved transitional I fitting. Transitional fitting attachment can pivot for adjustment to proper brace angle. I 900 lbs. (4.00kN) - Along Beam Finish: Plain, Electro-Galvanized and HDG Approx. Wt./100: 247.5 Lbs. (112.2kg) Order By: Figure number and finish US Patent #6;098,942, Canada Patent #2,286,659 /1 ---------------- TI (25.4mm) '1/2" Bolt & Nut Furnished Top View Designed to meet or exceed requirements of FM DS 2-8. * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? is the installation angle measured from the vertical. FM Approved design loads are based Fig. ic on ASD design method. Fig. 4L Fig. 825 Fig. 980 I-Beam Brace Fig. 1C Cooper B-Line, Inc.'s (Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line . bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PP_ 00 COOPER B-Line Beam, truss, or girder Beam, truss, or girder 1 Fig. 828 0 Shown with Fig. 980 Fig. 828 Shown Fig. ay pivot in any direction Fig. 828- Universal Sway Brace Attachment to Steel Size Range: One size accommodates all Fig. 900 Series sway brace attachments. Fits from /8" (9.4mm) to /" (22.2mm) thick steel structure. For thicknesses less than /8" (9.4mm) refer to Fig. 825. Material: Steel Function: To attach sway bracing to various types of steel structural members. Features: Permits secure non-friction connection without drilling or welding. Unique design allows offset placement on wide flange beam, I-beam, C-channel, open web, welded steel trusses, etc.. Secures brace to structure either across or along the beam. Break-off set bolts allow for visual verification of proper installation torque. Approvals: Factory Mutual Approved (FM). For UL Listed information refer to page 52. Installation Instructions: The Fig. 828 is the structural attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with a Cooper B-Line/TOLCO transitional attachment, bracing pipe' and a Cooper B-Line/TOLCO "braced pipe" attachment to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 828 on the flange of the beam, truss, or girder. Be sure the attachment is fully engaged to the rear of the opening. Tighten the cone point set bolts (A) until the heads break oft. Tighten the cone point set bolt (B) until the head breaks off. Remove the flange nut from set bolt (8). Install a TOLCO swivel fitting Fig. 980 or any other Cooper B-Line/TOLCO approved transitional fitting). Use flange nut to secure the swivel fitting. Finish: Plain or Electro-Galvanized Approx. Weight/100: 275 Lbs. (124.7kg) Order By: Figure number and finish Patent #6,098,942 Canada Patent #2,286,659 Patent Pending Designed to meet or exceed requirements of FM DS 2-8. ®TOLCcDO es APPROVED Gone Point Set Bolts A Set Bolts Included Cone Point Set Bolt B FM Approved Allowable Horizontal Load* With Brace Perpendicular To Beam Brace Angle (degrees from vertical) 300-440 450590 600-740 750-900 1570 2220 1210 700 (6.98kN) (9.87kN) (5.38kN) (3.11kN) FM Approved Allowable Horizontal Load* With Brace Parallel To Beam Brace Angle (degrees from vertical) 300-440 450-590 1 600-740 750-900 690 970 1210 1330 (3.O7kN) (4.31kN) (5.38kN) (5.91kN) FM Approved design loads are based on ASD design method. Cooper B-Line, Inc.'s ('Cooper 13-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper 13-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line APPROVED Set Bolt Included Mounting Hardware Is Not Included & SWAY BRACING Fig. 980 - Universal Swivel Sway Brace Attachment - I8" to 3/4" Size Range: One size fits bracing pipe 1 '(25mm) thru 2" (50mm), Cooper B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4" (31 .7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and Cooper B-Line/TOLCO "braced pipe attachment, Fig. 1000, 1001, 4L, or other TOLCO approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Approved by Factory Mutual Engineering (FM). For UL Listed information refer to page 60. Note: Fig. 980 Swivel Attachment and Fig. 1000, 1001, 4L or other TOLCO approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish. Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Designed to meet or exceed requirements of FM DS 2-8. Fig. 4L * Standard size. FM Approved design loads are based on ASD design method. Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Set Screw and Locknut Included 65-0" 11/4" 1 (31.7) 1 55 g:;'8 11/4" 1 (31.7) 1 55 Maximum loads for clamp with set screw in up or down position. (24.9) (24.9) HANGERS & SWAY BRACING Fi'6 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening Fig. 65)fl:- Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) n Size Range: Fig. - 1/2"_13 rod sizes, and /8-11 rod sizes Fig. 65 - /8-16 rod size (see below) Material: Steel with har ned cup point set screw and jam nut Function: Recommended f hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eli nates structural deficiencies associated with casting type beam clamps. May be us on top or bottom flange of beam. (Beveled lip allows hanging from top flange where cle ance is limited.) May be installed with set screw in up or down position. Offset design rmits unlimited rod adjustment by allowing the rod to be threaded completely thro h the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Ass iation (NFPA), pam let 13, /8"-16 rod will support 1/2" (15mm) thru 4" (100mm) pipe 1/2"..13 rod will support thru 8" (200mm) pipe Finish: Plain. Contact Cooper B-Line for alternative finishes and m rials. Order By: Figure number and finish Fig. 65 Patent #4,570,885 65-1/2 i/2"..13 1h /2/f' 3/4" (25.4) /16" 65-5Ie 3/4" /16" Fig. 65X1-3/8 - Beam Clamp Feature: Extruded holes allows for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Finish: Plain or Electro-Galvanized Order By: Figure number and finish Approvals: Underwriters Laboratories Listed (cULus) and FM Approved (FM) for up to 4" (100mm) pipe. Designed to meet or exceed requirements of FM DS 2-0. 3/4" (19.0) Set Screw and Locknut Included (22.2) (34.9) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pp— 00 COOPER B-Line Top Flange Attachment Applications U1 Bottom Flange Attachment Applications HANGERS & SWAY BRACING ®TaLcO Fig. 7 - Z-Purlin Malleable C-Clamp S Set Screw and L us Material: Malleable Iron Lockout Included 31 LIVID Function: Designed for attaching a -16 hanger rod to the — bottom flange of a Z-purlin. Approvals: Underwriters Laboratories Listed (cUL r up to 4" (1 00mm) pipe. Conforms to Federal Specification WW-H- & A-A-1 192A, Type 23 and Manufacturers Standardization Society 7 313/321. ANSI/MSS SP-69 & SP-58, Type 23. ( (86.5) Finish: Plain or Electro-Galvanized I Order By: Figure number and finish. Weight: Approx. Wt./100 90 Lbs. . g) ç" / /j' Throa ning Design Load: 400 Lbs. 1 IJ/ ,f 1/32" (24.6) Setscrew Tor er MSS SP-58 14.2.5 Bottom Hanger Rod /8 -16 crews = 5 ft./lbs. II Threads ion should be taken not to over-tighten set screws. Fig. B3033 - Wide Jaw Reversible C-Clamp (TOLCO Fig. 68 & Fig. 68W) Size Range: /8'-16 thru /4'-10 rod Material: Cast Malleable Steel with hardened cup point set screw and jam nut Function: For attachment to structural shapes requiring wider throat especially under roof with bar joist construction. This clamp may be used with the set screw in the up or down position. Approvals: Underwriters Laboratories Listed (cULus) and Factory Mutual Engineering Approved (FM) for /8"-16 and 1/2"..13 rod sizes. Conforms to Federal Specification WW-H-1 71 E Type 19 & A-A-1l 92A, Type 19 & 23 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 19 & 23. Factory Mutual Engineering Approved only with the setscrew in the down position. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size and finish Note: Do not over tighten set screw. Setscrew Torque: Per MSS SP-58 14.2.5 /8" -16 set screws = 5 ft./lbs. • 1/2" -13 set screws = 11 ft./lbs. ' 5/8" -ii set screws = 21 ft./lbs. Caution should be taken not to over-tighten set screws. Designed to meet or exceed requirements of FM DS 2-0. Throat Opening 11/4" (31,1) for B3033-/s & 1 15/16' (33.3) for B3033-5/s & Size) r Rod cluded Set Screw and Locknut included All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PP_ 00 COOPER B-Line Fig. B3034 - C-Clamp (TOLCO Fig. 68S) Size Range: /8"-16 thru /4"-10 rod Material: Cast Malleable Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4 (19.0mm). Features: May be used on top or bottom flange of the beam. Beveled lip allows hanging from top flange where clearance is limited. May be installed with the set screw in the up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. The rear window design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed (cULus) and Factory Mutual Engineering Approved (FM) for /8"-16 and 1/2"13 rod sizes. Conforms to Federal Specification WW-H-1 71 E & A-A-1 192A, Type 23 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 19. /8"-16 is (cULus) Listed to support up to 4 (100mm) pipe with the set screw in the down position, up to 3" (75mm) pipe with the set screw in the up position. 1/'2"..13 is (cULus) Listed to support up to 8" (200mm) pipe with the set screw in the down position, up to 6" (150mm) pipe with the set screw in the up position. Factory Mutual Engineering Approved only with the setscrew L in the down position. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size and finish Setscrew Torque: Per MSS SP-58 14.2.5 /8" -16 set screws = 5 ft/lbs. • 1/2" -13 set screws = 11 ft./lbs. Caution should be taken not to over-tighten set screws. B3034-/8' and B3034-/4' sizes Attach only as shown. Throat Opening 3/4' (19.0) - - H Set Screw and Locknut Included A (Rod Size) Hanger Rod Not Included Bottom Flange Attachment Applications Part Rod Set Screw Maximum Iron Approx. No. Size Size B C D Pipe Size Per UL WL/100 B3OB3034-%I80 -16 3/8"-16 X 11/20 1/8 (41.3) 2 (50.8) /8 (19.0) 4 (100) 30 (13.6) B3034-1 /2 1/2"-13 1/2"-13 01/2 113/16" (460) 2/i (556) 1/16 (30.2) 8" (200) 47 (21.3) B3034-5/8 /811-11 1/2"..13 x 2" 1/4" (44.5) 21/8' J, (54.0) 11/4" (31.7) -- -- 58 (26.3) B3034-3/4 /4"-10 112"..13 x 2" 2" (50,8) 21/4' (57.2) 1 11/4" (31.7) -- -- 77 (35.0) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PP_ 00 COOPER B-Line ' I nreaaeu mucebburieti I:[c:YflV1:1:YI[cU Fig. HN - Standard Hex Nut (TOLCO Fig. 113) Size Range: 1/4"20 thru /8-9 Material: Steel Finish: Plain or Electro-Galvanized. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number size and finish Fig. HHN - Heavy Hex Nut (TOLCO Fig 114) Size Range: 1/4"..20 thru /8-9 Material: Steel Finish: Plain or Electro-Galvanized. Contact Cooper B-Line for alternative finishes and materials. fl Order By: Figure number size and finish I C All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PP— 00 COOPER B-Line Fig. FW - Flat Washer (TOLCO Fig. 115) Size Range: 1/4°.20 thru 1-8 rods Material: Steel Finish: Plain or Electro-Galvanized. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number size and finish Fig. LW - Lock Washer (TOLCO Fig. 117) Size Range: 1/4"..20 thru 1-8 rods Material: Steel Finish: Plain or Electro-Galvanized. Note: Available in Hot Dip Galvanized finish or Stainless Steel materials. Order By: Figure number size and finish Fig. FFW - Flat Fender Washer (TOLCO Fig. 119) Size Range: /8-16 and 1/2'..13 rods Material: Steel Function: To provide a greater bearing surface than standard washer. Finish: Plain or Electro-Galvanized. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and size S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. pp— 00 COOPER B-Line Fig. B655 - Steel Rod Coupling (TOLCO Fig. 70) ®TOLCO Fig. B656 - Steel Reducing Rod Coupling (TOLCO Fig. 70R) Size Range: 1/4'L20 thru 1-8 rod Material: Steel Function: Used for coupling two threaded rods together of equal or reduced rod sizes, with or without inspection hole. Finish: .Electro-Galvanized. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish PartE[i. B655-114 B655-31s For r' I Length /t (22.2) Design Load 300 (1.33) Approx. 1.9 Wt./100 (0.86) I8"-16 11/8 (28.6) 7307(3.25) (3.25) 3.6 (13) B655-112 112"_13 114" (44.4) 1350 (6.00) 11.3 (5.12) B655-518 /8'-11 21J8 (54.0) 2160j(9.61) 17.6 B655-314 I4-10 21/4' (57.1) 3230 (14.37) 28.1 (12.74) B655 1a /8 9 21/2 (635 44801(1993) 572 (2594) B6551 1-8 2/4 (69.8) 5900 1 (26.24) 73.7 (33.43) IF-li LLIJ - I B655 B656 Fig. B3220 - Rod Coupling (TOLCO Fig. 71) Size Range: /8"-16 thru 1-8 rod Material: Steel Function: Used for coupling two threaded rods together of equal rod sizes, with inspection hole. Finish: Electro-Galvanized. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish Rod veII' Hanger 7;I1 0 Length S Wi. B3220-1I4 1/4"_20 Overall 1 ength 1/8" lli1 4 (34.9) Design Load 300 (1.33) Approx. Wt./100 6 (2.7) B3220-l8 x 114 l8"-16 to 1/4"..20 1/a" (41.3) 300 (1.33) 11 (5.0) B3220-31ø /8-16 1/8" (41.3) 730 (3,25) 10 (4.5) B3220-112 x 318 B3220-1/2 B3220-51e 1/2"-13 to 3/8 16 21/8" (540) 730 (325) 20 (91) 1/2"..13 21/8 (54.0) 1350 (6.00) 20 (9.1) /8"-11 21/2 ' (63.5) 2160 (Ml) 32 (14.5) B3220_314 /4"-10 2/8' (66.7) 3230 (14.37) 42 (19.0) 133220-710 B3220-1 /8-9 1-8 3/16 2/4" (55.6) (69.8) 1 4480 j9.9_ 5900 (26.24) 91 100 (41. 3) (45.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pp- 00 COOPER B-Line HANGERS & SWAY B Fig. B3188 - Standard U-Bolt with 4 Hex Nuts (TOLCO Fig. 110) Fig. B3188C - Standard Plastic Coated U-Bolt Size Range: Size1/2" (15mm) thru 30' (900mm) pipe Material: Steel Function: Recommended for support, anchor or guide of pipe. Approvals: Underwriters Laboratories Listed 3/4" (20mm) thru 12" (300mm). Conforms to Federal Specification WW-H-1 71 E & A-A-1 192A, Type 24 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 24. Maximum Temperature: 750°F (399°C) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish. U-bolt can be furnished with longer tangents "D" or with longer threads "E". Consult factory. Note: When furnished in Hot-Dip Galvanized finish, oversize tapped hex nuts must be used. B3188NS - Non-standard (NS) U-bolts are available upon request. Specify dimensions other than standard. 83188Dl - For ductile iron pipe. i ®ToLccr c®U8. - LISTED A bread Size Hex Nuts Included TI Thread Length Design Load 1 83188C Plastic Coated Design Load 2 Design Load 3 Part li.No. Pipe i. Size Thread Size Thread Length il TL B B3188-1/2 1 1/2"(15) 1/4°20 I 2/s" (54.0) 15/16" (23.8) /4" (20) 1/4"_20 21/8" (54.0) 11/8" } (28.6) B3188-/4 1" (25) 1/4"20 21/8" (54.0) 1/8" (34.9) 83188-1 B3188-11/4 11/4 (32) 3/8"-16 21/8' (540) 111/16' } (429) 83188.11/2 11/2" (40) I8"-16 21/2" (63.5) 2" (50.8) B3188-2 2 (50) 3/8"-16 21/2 (635) 27/i& (61 9) B388-21I2 21/2" (65) 1/2"..13 3" (76.2) 215/16" (74.6) B3188-3 3 (80) 1/2 13 - 3 (762) 3/i& } (905) 83188-31k 31/2 (90) /2"-13 3" (76.2) 41/16" (103,2) 83188-4 (100) 112"_13 3" (76.2) 83188-5 (125) 1/2"13 3" (76.2) 521/32" (143.6) B3188-6 (150) 5/811-11 33/4" (952) 63/4 (171 4 * 83188-8 8" (200) /81,-11 33/4" (95.2) 8/4 " (222.2) 83188-10 10..(250) 3/4,,_10 4 (101.6) 10/8 (2762) 12 (300) 7/8%9 41/4" (1079) 12/8 (3270) B3188-12 B3188-14 14 (350) I811-9 41/4" (107.9) 141/8" (358.8) For larger sizes consult full line pipe hanger catalog. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pill— 00 COOPER B-Line 4 'SCHEDULE- 10/40 ¼.II I_'..IIl I'.JF I I'...II ¼JI__J I I'..#IM (....C.. Schedule-1O®/Schedule-40® Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-1O/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1/4"_ 8") pipe and Sch-40 (1"- 214") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule- lO/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (IvHC) when the First Sprinkler System is first installed. Ameri can Made Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Sch-40 Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wt/Litt (24') WI/Lilt (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1¼' 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 11/2 " 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 21/2" 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-10 Specifications NPS Nominal I.D. Wt. Wt. (HiD Filled) Pcs/ Wt/Lilt (21') WI/Lilt (24') Wt/Lilt (25')' In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 11/4' 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 11/21, 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tqco/Flow Control Qr allied TUBE & CONDUIT (~) <~> 9 Listed Approved Listed 16100 S. Lathrop• Harvey, IL 60426 Customer Service: 11350 Norcom Rd.. Philadelphia, PA 19154 (800) 882-5543 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5 -3 FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type F, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that 10 outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES IIII1i1[ lrm 1 In L mm Eibs./ft kg/rn Lift 11/4 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 11_j 1.900 483 1.682 427 It L 277 209 311 58 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 2j 2875] 730j 2635 669 120 [ 305 353 526 L s 30 3 3.500 88.9 3.260 82,8 .120 3.05 4.34 6.46 2.6 19 4.260 1082 120 57 562 11 837 [ 16 i 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 I 6625 1683 1 6,357 161 134 I 340 930 1385 10 10 ......... 8 8.625 219.1 8.249 209.5 ' .188 4.78 16.96 25.26 2.1 7 Calculated using Standard (ii. CRR formula, UL Fire Protection Directory. Category VIZY. The CRR Is a ratio value used to measure the ability eta pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES in mm TLI [lbs/ft ][k9/rn JCRR j LIft 1 1.315 33.4 1,049 26.6 .133 3.38 1.68 2.50 1.00 70 1.380 351 1140 227 339 51 11/2 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 30 Calculated using Standard UI. CRR formula, UL Fire Protection Directory, Category VlZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). @ C@ APPROVED PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: WOCATIONS: COMMENTS: El BLACK El HOT-DIP GALVANIZED Wheatlaiid Tube FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Schedule 10 Pipe Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. All Schedule 10 and Schedule 40 pipe has a pressure rating of 300 PSI. 1.315 i 1.097 141 lbs/ft 91 j 1.11/4 1 6 t 61 1.682 2.09 lbs/ft 61 2.375 17 1 Lt J[ 53 lbs/ft 30 ____ J1 - 4.4 Ibs/ft 19 F4 I 4 1 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe 111li () - _Gaaw&aft I mmg4a L mupimt - 1315 1049 - 1.68 lbs/ft 70 11/4 1.660 1.38Oj 2.27 lbs/ft 51 .... 110 [1_1L J9..QP _IJbs ItL L 44 2.375 3.66 jbs/ft 30 2-875 5.80 lbs/ft 30 19 4 4.500 4026_— - 1080 lbs/ft r 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, QN, 6 Chesterfield, MO 63017 contact your salesperson C®US/ • (800) 325-4467 today at (800) 325-4467 or USitU BLLL. MOOSE TLE CO N'Y FAX: (636) 537-2645 (636) 537-2600 in the USA, www.builmoosetube.com. or from Canada Ae> ACcompany e-mail: saies(buIlrnoosetube.coin call (800) 882-4666 ______ RR APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 DUCTILE I RONf!IsIDEG. ELBOW NOMINAL SIZE (INCH) IITEM ' CODE # MAX. WORKING P.S.I. DIM IONS WEIGHT' - A - B EACH PIECE 1 DB90033 500 1.50 1.50 0.62 1.1/4 1 DB90044 1 500 1 1.75 1.75 0.90 1 1/2 1 DB900551 500 1 1.94 1.94 1 1.20 2 1 DB900661 500 1 2.25 1 2.25 1 1.85 DUCTILE I RO 1:11 ajeTiDEG. ELBOWj NOMINAL SIZE (INCH) ffBvl CODE # MAX. WORKING P.S.I. DIMENSIONS WEIGHT - A B EACH PIECE 1X1/2 DB90031 500 1.26 1.36 0.44 1X3/4 DB900321 500 1.37 1.45 0.52 1 1/4X1/2 DB90041 500 1.34 1.53 0.64 1 1/4X3/4 DB90042 500 1.45 1.62 0.72 1 1/4X1 D890043 500 1.58 1.67 0.75 1 1/2X1 DB90053 500 165 1.80 0.92 1 1/2X1 1/4 D890054 500 1.82 1.88 1.08 2X1/2 DB90061 500 1.49 1.88 1.08 2X3/4 DB90062 500 1.60 1.97 1.24 2X1 DB90063 500 1.73 2.02 1.40 2X1 1/4 DB90064 500 1.90 2.10 1 1.52 2X1 1/2 DB90065 500 2.02 2.16 1 1.65 U DUCTI LE IR.] I Ic NOMINAL' SIZE (INCH) ITEM CODE # ' MAX. WORKING P.S.I. IDIMENSION I WEIGHT I EACH PIECE A 1 DCL033 500 1.67 0.40 11/4 DCLO44 500 1.93 0.57 11/2 DCLO55 500 1 2.15 0.75 2 DCL066 500 1 2.53 1.15 DUCTILE I RO F !i DEG. ELBOW NOMINAL SIZE (INCH) ITEM CODE I MAX. WORKING P.S.I. DIMENSIONS WEIGHT I A B EACH PIECE 1 DB45033 500 1.12 1.12 0.46 11/4 1 DB45044 500 1.29 1.29 0.73 1 1/2 1 DBOO551 500 1.43 1.43 0.92 2 1 DW0661 500 1 1.68 1 1.68 1.50 IDUCTILE I RONiSTRAIGHT i NOMINAL' SIZE (INCH) ITEM ' MAX. CODE WORKING # P.S.I. DIMENSIONS WEIGHT I - A B EACH PIECE 1 DT333 500 1.50 1.50 0.85 11/4 DT444 500 1.75 1.75 1.22 1 1/2 DT555 500 1.94 1.94 1 1.55 2 DT666 500 2.25 2.25 1 2.45 DUCTILE IRO IaRED. COUPLINGl NOMINAL SIZE (INCH) ITEM CODE # ' MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A 1X1/2 DRC031 500 1.69 0.39 1 X3/4 I DRC032 1 500 1 1.69 1 0.53 S orcuirium I iji',i IL I iji' STAR®PIPEPRODUCTS D.I. THREADED FITTINGS (0 * <~> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Ductile iron threaded fittings are UL, ULC listed and factory mutual approved for 500 psi service. Ductile iron perASTMA536 grade 65-45-12. Dimensions conform to ANSI B16.3 class 150. Threads are NPT per ANSI/ASME 131.20.1. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittingd should be tightened theree turns beyond hand tight, but no more than four turns. Page 21 -L '1 7ti1 OUTSIDE HEAD DUCTILE I RON BUSHING IIMIFJJ SIZE (INCH) ITEM CODE # I DIMENSIONS STYLE ' I WE EACH - A - B - C lxl/2 DBUSH31 0.75 0.25 1.42 OUT 0.22 1x3/4 DBUSH32 0.75 0.25 1.42 1 OUT fjJ 1 1/4x1 DBUSH43 0.80 0.28 1.76 1 OUT 0.28 1 1/2x1 DBUSH53 0.83 0.31 2.00 OUT 0.44 1 1/2x1 1/4 DBUSH54 0.83 0.31 2.00 OUT 2x1 DBUSH63 0.88 0.41 1.95 IN 0.66 2x1 1/4 IDBUSH64 0.88 0.34 2.48 OUT 0.72 2x1 1/2 1 DBUSH65 0.88 0.34 2.48 OUT Ifl il Iii DUCTILE IRON REDUCING TEE WORKJNG P.S.I. EACH PIECE MAX-.-MMEEZZWEIGHT mRamm Emil - 'ijui'.w*x* Ulm IIrL):s.rJ:4Ir1 JfrEJjjJ fr4fr i i.frZ - frIIFL'i I.1. 'I'R*P*P* ViUEE+ Ti uk'4:4' - - 'iii*.iiaw p* - - - 9 Ila INSIDE HEAD S A SPECIFICATION SECTION 2.2.17 D.I. THREADED FITTINGS STAR®PIPEPRODUCTS © LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 DUCTILE IIRON CROSS I NOMINAL SIZE (INCH) I ITEM CODE ' MAX. WORKING P.S.I DIMENSIONS WEIGHT I - A - B EACH PIE 1 DX033 500 1.50 1.50 0.98 11/4 DX044 500 11.75 , 1.75 1.50 11/2 DX055 500 1.94 1.94 1.90 2 DX066 500 2.25 1 2.25 2.95 1 1/4X1 DX043 500 1.58 1.67 1.27 1 1/2X1 DX053 500 1.6511.801 1.48 2X1 DX063 500 1.73 1 2.02 1 2.10 Page 22 DUCTILE IRO NOMINAL' SIZE (INCH) ITEM CODE # I MAX. WORKING P.S.I. 0IMB4SIONI WEIGHT' EACH PIECE A 1 DCP003 500 1.16 0.32 11/4 OCP004 500 1.28 0.43 11/2 DCP005 500 1.33 0.60 2 DCP006 500 1.45 0.91 I ON SECTION 2.2.F Anvil standard and extra heavy cast iron threaded fittings are manuactured in accordance with ASME-1316.4 (except plugs and bushings, ASME B16.14). Dimensions also conform to Federal Specifications, WW-P-501 (except plugs and bushings WW-P-471). c®Us APPROVED For Listings/Approval Details and Limitations, visit our website at ww.anvilintl.com or contact an Anvil Sales Representative. Cast Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 125 .,lass 250 (F) -200 to 1500 (C) -28.9 to 65.6 ps 175 b6 12.1 psi 400 bar 27.6 2000 93.3 165 11.4 370 25.5 2500 121.1 150 10.3 340 23.4 3000 148.9 140 9.7 310 21.4 0 350 176.7 125 8.6 300 20.7 4000 204.4 - - 250 17.2 Standards and Specifications Dimensions Material Galvanizing Thread Pressure Rating j Federal/Other CAST IRON THREADED FITTINGS Clasr 125 ASME 816.4' ASTMA-126(A) ASTMA-153 ASMEB1.20.1+ ASME 1316.4- ASMEB16.4U CIEs 250 ASME B16.4' ASTMA-126 (A) ASTMA-153 ASME B1.20.1+ ASME 816.4' ASME 816.4U CAST IRON PLUGS AND BUSHINGS ASME 1316.14• ASIM A- 126 (A) I ASIM A-i 53 I ASME B1.20.1+ ASME B16.14' VW-P-471 an American National standard (ANSI), + ASME 131 .20.1 was ANSI B2.1, U Formerly WW-P-501 STM B 633. Type I, SC 4, may be supplied as alternate zinc coating per applicable ASME 1316 product standard. 36 www.anvilintLcom S '.C:oE CtoE' wel LO _ No. 001 No. 003 C to E IF to 1b No.- 062 No. 006 SPECIFICATION SECTION 2.2.K 10.03 0 FireLock® Fittings FirøLQck' products comprlse..a urquesystem sp.ecificaIlydestgnd for fire protection services. FireLock full flow elbows and tees are a CAD developed hydrodynamic design that has a shorter, center to end dimension than standard fittings A noticeable bulge allows the water to make a smoother turn to maintain simf tar fl*w characteristics e'standard full flow fittings. F r I o k Fittings are designed for use xclusiveIy with Style 005 arid Style 009 I- IreLock coi ipllngs Use of oIhH' Cr)Upliflgs or flange adapters may result in bo[t pad i nterfereace. Victautic flreLdck fittings pressuto couplings. Patented See VtL4lO pubtctn I 0,01 for cpts 0 DIMENSIONS ratings conform to the rani of Victaulic FireLock Style 005 No. 001 No. 003 No. 002 No. 006 FithngSe 90 Elbow 45 Fibow Straighhtee Cap________ Actual Aprx Apr 11 Api Thickness Apa. Nominal Outside C to E, Weight 0 to Weight Ct E Weight Weight Diameter Diameter inches Each inches Each Inches Each tnchee Each inches/mm Inches/mm mm Lbsikq mm Lbsikg mm Lbslkg mm LbSJkg 11/ 1,660 - - - 0.92 0.3 42,4 - - - - - .- 21 01 1.000 2,75 .1.2 1,75 0.0 2.75 2.0 41 0.92. 0.4 70 0.5 45 0.2 22.375 ' 2.75 11.7 20O 1.9 2.75 2.4 0.88 0,5 50 50.3 70 .0. 0.8 7* ii 22 2.875 300 3.1 2.25 '2.2' 3.00 3.6 0:88 1.0 73.0 76 1.8 .57 1.0 78 1.6 22. 0.5 76.1 111111 3.000' 3.06 130 2.25 Z4 - 7E1 76 '1.5' 57 1.1 - - I 3,500 3.38 ,0 2.50 3.1 3.38 5$ 0.88 1.2 589 86 04 1 89 2.4 22 0.5 4.350 'Tt2." 51 300 50 .4:0 7,5 - 1J0 102 . 102 34 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1,00 2.4 100 114.7 102 TO 16 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.9 124 1.1 25 1.0 6.250 5.50 12.6 3.50 9.2 3.50 17.9 - - 159 mm 158.8 140 1 5.7 89 4.2 140 8.0 -' - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 ISO 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.1 '1.13 12.1 200 219.1 1 113 11.5 108 9.3 176 11.6 29 5.6 MG19TOP TRMAREOFVICT.*AjUC C 00PYRIGHT 2,04MMUM-. PRIM INUSA 5W$PAS47PJLO United States. Phone: 1-MO-PICK-MC (1-800-742-5842) • Fax:610-250-8817 'e-mail: pic0ic0icIau9ccom Canada 'Phone: 905-884-7444 • Fax: 905-884-9774 • e-mail: viccanada©victauiicom Europe • Phen. 32 9-381 1500 • Fax. 32-9-380-4438 • e-mail vceuiov,clauiic be UK • Phone. 44(0)1438741100 • Fax 44(0)1438313883 • e,-maili viceuroMctauiic be entraI sod South Pjnerioa 'Phone 610-559-3300 • Fzc 610-59-3608 ' e-malLvcsldauhccom Auetralasla * Phone: 86-21-54253300 • Fax-,86-21-54253671 c-mali eica©v1cI2uI C 501' 539 REV F j(atau1ac I _W11 I '.J% I 1%..I. I J I_ _# I l'..J I 4 4 .4_.l FLOW DATA Frictional Resistance FfttineSlze Equivalent Ft/meters d Straight Pipe Actual Straight tee NominaL Outekis No, 002 Diameter Diameter 90# Elbow 454 Elbow Inches/mm Fnchssflnm No, 001, No 003 Brasch Run 1114 1.660 1;5 (LB 3.7 'LB 32 42.4 015 0.2 1.1 05 11/2 i;goo 2.2 11 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 63 60.3 1.1 0.5 2.6 11 2 1, 2875 43 22 108 43 63 710 13 0.7 13 1.2 76.1 mm 1.4 3.000 4.5 2.3; 1.0 4,5 0.7 34 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108 mm 1000 2, 0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 ico 114.3 21 1.0 4.9 21 5 5.563 8.5 4.2 21,0 8.5 125 141.3 2.6 1.3 6.4 2.6 r 1.,9 mm 6.250 9.4 4.9 25.0 9.6 168.8 2.9 1.5 7.6 2.9 8 6625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.6 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.8 1.5 10.1 4.0 The flow dote lieted i3 hosed upon the preseure drop of Schedule 40 pipe. MATERIAL SPECIFICATIONS 11 Fining: Ductile Iron conforming to ASTM AS364 grade 654542 Fitting Coating: Orange enamel Optional, Hot dipped galvanized This product shall be manufacturad by Victaulic Of to Victaulic specifications. All products Lobe installed in acoordanmwthcurrentVictatIic insralislionlassembly instructions. Victaukc reserves the right to change product specifications. designs and standard equipment without noticesndwithout incurring obligations. 2 FireLock-0 Fittings S JOB/OWNER System No. CONTRACTOR ENGINEER Submitted By - Sec Sect, ___________ Pare__________ SPECIFICATION SECTION 2.2.K FireLockO Rigid Coupling STYLE 005 WITH VIC.PLUSM GASKET SYSTEM (NORTH AMERICA ONLY) FireLoce Style 005 iriffid coupling has a UnFe, patented arigk-pad desigwhkTh the housings to ollet while clamping the grooves by permitting the hQUSIngS to slide on We angled bolt pads, rigidity is obtai bed. Support and hanging requirements cat respond to NFPA 13 Sprinkler SystëmS.Angle-pad design permits assembly:by•rerrovng one mot/bolt and swinging the housing over 1.112gst, This reduces components to handle during assembly. Style 005 FireLock .coupling are designed and recommended for use ONLY on fire protection systems. VlcPlU5TM Gasket System In North America; VlctauIic offers a gasket system whiCh requires no Md lubrication on wet pipe systems that are hydrostatically tnted The VV Plusrm System (patented) is dry, hoan.nd non4dc. It redtrces assembly time substantially and eliminates the mess and cliane of ver- lubrication. Please refer to the latest copy of the Victaulic,Field Installatibri Handbook(lLiOO) for supplemental lubrication retuirements and dry pipe fire protection system nos, j SEE VICTAULIC PUBLICATION tO01 FOR DETAILS C .t 5yztm LISTING/APPROVALS The information provided below Is based on the latest listing and approval data at the time of publication. Listings/Approvals are sr bectto change and/or additions by the approvals agencies. Contact V ctaultc lot perlormauce on aiher pipe and the latest lisUngs and approvals. rMappoved *,rsétvlcetrr I Pi-4 ptpe. # ULUted for WVKe Up to 4 pipe I)r* @ UL Listed for service up to 3 only. Location Date Approved Date www.victaulic.com VtCTAUL1C IS REGISTERED TRADEMARKOFVtCTAUUC COMR N' 0 200G VtCTAUUC COMPANY, ALL RId-ITS RESERVED. PitNTEO Ir'l TtIE LISA. Orly I 'Jct,uIic. it. flQ 1 DIMENSIONS Rated for wet and dry Idntter yrm at I50pV24i3kPa fot ½ 1/32- lOQmr sizes and 300 psi I2066kPa for 4-84l08 - 200mnr sizes Schedule lGroll grooved or Schedule 40 cut or roll grooved pipe. Style 005 is rigId aM dpes noi wcnnrmcdsre dxpanlrn. c onuac tiomorarrgtjbr 6e1cc2)on, IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS SPECIFICATION SECTION 2.2.K iu.0 FireLock® Rigid Coupling STYLE 005 WITH VIC.PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) Max, End Al:o Pipe 13011mnol Approx. ilz i3 ii4Li ,11 5. 44 Lob. be 16.60 320 722 CI6 7 I 4.50 1 18 70 1900 35l) 0 Obe 2 3D0 475 be8 12 40 48.3 2413 446 10 76 T21 148 05 2 375 0 350 525 1.88 14 $9 M413 - T 2 - :x2 Th _7 2 ...i 1.7 1 t0 I146 14a .09 _ 1. . mn "lb. - re? 2 13 10' 546 148 0. 5 3000 350 35/.0 0.07 2-x'S5 6.13 128 2.1 40 68.9 2453 14985 17 MB 156 148 ID 00 5 55 0 i6l2 57 725 13 31 1145 :;3 2174 4: 147 124 54 U 4250 300 25 2.13 3 1080mm 4255 0.16 2 5.63 508,0 2064 18940 Al 143 184 54 (4 S - 5.533 300 7200 414 68 9.00 2.13 40 25 I Lo63 3711>, 175 22 51 04 3.Qrnçn 5.250 340 5455 ji , 643 2-21S #ZX 9.00 553 '45 a3.0 3453 7393) 4 168 229 54 25) rr 1Pzs j13, 48 0 i1s, ces 9.00 6 6525 540 10140 010 10.00 2.13 5.0 150 168,3 068 46020 4.1 2-14 533 254 53 2.3 6220 159 0,. 3557 2250 0 .., 703 1000 713 8.8 "81- J 2. 2 I& 6.300 61 300 9335 4A 44295 0.16 4.1 -. 815 I.00 2-½s 2W 254 5,13 54 5.5 2,5 S $425 300 17525 0.19 1050 13.14 1 763 U3 500 219.1 251P3 77744 471 257 334 67 51 Working Pressure and End Lad ate .roraf from aft in rrr1 and external ioadsbated on standard ghtAl1S steel pipe, szamfard F90 of utgrocrn- iri Jene vogb Vktutic spe~cVicaopm, Co ctVt kfr perfr tmrnceon42<rpioe, Fr I P, 5NcTI! FIEIDTEST ONLY, theM 'rrrWo g Fret ur l'en re) ' to I In 61&0S the fcures trtcwrr. 3 he eIab1e pp S--ratio dinienstor sown ts Icr s cri lawot noses ow. Syks 005 Couplings ate con rerd rig 0. con ne,i0ors and s411 n000dar x0nsr0vi o c. r:ctcn o t7iapiping srstem, Num6er of f:itr req iwO or r.trs number CJ 1101JrLng w4Tonss Mr ewblc io1 cc.3o0 § Style 005 couplings are VdS and (PC Approved to 12 8ar1175pst www.victaulic.com \'lCTAUUC IS REGISTERED TRADEt44" K 04 VICTALBJC COMPANY 02006 VICTAiJUC COMPANY ALL RIGHT RESERVED. PRINTSD (N TIlE j3A. Alm~tauho S S JOB/OWNER System No. CONTRACTOR ENGINEER Submitted By Spec Sedt___________ Pare_________ 61±(1bft.A I ION Sbi I ION 2.2.K Coupling STYLE 75 ® <a> 4 E9 ILPCBI SEE VIcTAULIC PUBLICATION 10.01 FOR DETAILS Style 75 is avàilabtewhère moderate pressures are expected or weight considerations are a factor, Up to O% lighter In weight than the Style 77, the Style' 75 coupling is recommended for service up to 500psi/34501<1?a depending on sire. Housings aie cast in two kierillcal pieces in all skes. Hot dip galvanized and special coatings are available for at sizes Egrc.J MATERIAL SPECIFICATIONS.. Housing: Ductile i/on conforming to ASIM A-536, grade65.45-12. Ductile iron cOhlOr Ming to ASTM A-395 grade. 65-45-15, Is available upon special request. Housing Coating; Orangti enamel Optionak Hut dipped galVal /Ld dod (JO !r5,. Gasket: (specify choice) Grade °E' EPDM EPOM (Green color code. Temperature range —30°F to +2306 FI_34C to .i.110°C . Recommended for hot water seivtc within the Specified temperature range plus a variety of dilute acds, oil tree air arid many chemical services UL classified In accordance with ANI'N8F 61 for mid 86 F/i 31( C and hot +1S0°F/i 8? C ptblc water srvlce NOF rj[N3[) FUR PLTFP)I 11V SERVICES Grade U7fl nitrite Nitrite (Orange color code) Temperature range —2OF to +180°F/-29°C to +82°C Recommended for petroleum products air with oil vapors vegetable and minerat oils within the specified temperature range except hot, dry air over+140°F4600C and water over +101'Ff+660C NOT RECOMMFNtfD FOR HOT WATER SFRVICES * Services listvd are General Service Recommendations Only, it should be noted that there are services for which these gskets are riot recommended. Referncce shOuld always be made to the latest vujaullc casket SelE coo Guidefor specific gasket s rye e recommendatlonq and fore listing of services which are not recommended Boils/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemicaf requirements of ASTM A 449 and physical requirements of ASTM A 183. Location Date Approved Date www.vlctaultc.com VICTAUtIC iS A RtGrSTEREO TBAW - 1cTh 0M UUC CPY C 2006 VICTAULIC cOl4PAttY ALl. Ribi-ITS RESERVED MINTED IM THE USA.A_~U_ho on, LI tIC fl I CARBON STEEL PIPE - GROOVED COUPLINGS SPECIFICATION SECTION 2.2.K QbIU Coupling STYLE 75 S DIMENSIONS I 42 Li4 2 .i I 2rr1 _i4__ ___.1____•l 25 334 50D 680 0-0.06 3450 3028 0-1 0.57 48 61 i 127 45 1.3 114 32 Im 42.2 - 500 3450 1080 0-006 4805 - 0-14 . - 045 1 38 1 .98 68 A i 177 45 0 * I iS 1= 500 1,420 0 0.06 2 40 4&3 3450 6320 0-1.6 33 74 45 016 2 2375 50.) 2,215 0-006 31 0.32 343 . 88 17 SO 603 3450 gm 0-14 26 87 131 48 OR 2½ 2,875 503 3.245 0-0.06 is, 0.26 7- 2 388 5i8 i8 1-9 65 73.0 3450 40 14-40 0-1.0 22 X 98 14-1 4 761mm ,. 33X)O 5 0-008 026 0.) 4. 188 1,9 76.1 2456 15730 0-1.4 22 ''' 102 7: 48 03 31 3.500 500 4XO 0-0,06 1 022 .,. 4.50 700 L88 23 80 889 .5O 71360 0 L6 ' 1(23414 48 13 4.003 50.) 6.300 0-0.06 019 2 2) 5.00 7..O 1.88 1 2.9 00 1Q14 3450 28035 0 14 16 - 177 19" 48 13 4 4300 SOD 7,050 00.13 r 0.34 $80 803 2.13 4.1 100 114.3 4250 3450 450 35380 0-32 4326 0-013 28 035 - 147 53 54 I 213 19 1081) 26 -.---* 28.3 - 2 --,-.-- l --- 0-Oi * 29 -- 0.25 80 - 3,14 141 613 ts 54 3 213 / *--- 4'h 120 1 1270 9100 39250 0-3.2 21 5 5.563 '130 10.1)35 0-033 1 18 2 314 6.88 10.67 213 88 125 141.3 3100 48660 0-3.2 23 T ' 175 256 54 16 1330 m 5250 m 450 9,735 0-0.13 028 - X 1 8Th 655 937 213 6.0 1331) -310.0 43325 0-32 - 74 168 738 54 17 450 10,665 Cl 0)3 0.28 68.0 5500 213 1397 3121) 47480 0-2.? 24 73 54 12' 021 1534mm 4 ..3 V4 1.88 152.4 3100 36676 0-3.2 18 187 266 48 28 6 6.625 450 15.525 10-033 023 . 81)0 07 113 70 150 - 168.3 _3100 69085 0-3.2 - 1$ 2O3 ,2Si54_ 3.2 Continued on page 3. t @ * Refer to notes-on page 3. \A till -., www.vktaulic.com VTAOL1C MA REGISTERED TRADEMARK OF VICTAUUC COMPANY. 02006VICTAUUC COMPANY. ALL RIGHTS RESERVED. PRINTW IN THE US& tic cit -) \ A-c-tauke 0th Li S Vic®-End II End of Run Fitting SERIES 67 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The No. 67, Vic5-End II, End of Run Fitting is the fast, easy, economical way to end a branch line. The fitting installs easily with standard FireLock® couplings and allows direct head connection, sprigs or drops. Available in 11/4, 11/2, 2 and 2 ½732-65 mm sizes, the fittings can be supplied with ½, 3/4, or 1/15, 20 or 25 mm female threaded (NPT) outlet (BSPT option available). The 900 reducing outlet fitting is UL/ULO Listed and FM Approved for a maximum rated working pressure of 500 psi/3450 kPa. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12, painted Orange Enamel. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Galvanized - hot dipped. Outlet: NPT Optional: BSPT DIMENSIONS, PERFORMANCE 1 Y4 X ½ NPT 2.38 1.4 2.8 32 15 NPT 61 0.6 0.9 2.38 1.4 2.8 54 NPT 20 NPT 61 0,6 0.9 1 NPT 2.38 1.4 2.8 25 NPT 61 0.6 0.9 11/2 X ½ NPT 2.50 1.6 2.9 40 15 NPT 64 0.7 0.9 2.50 1.6 2.9 44 NPT 20 NPT 64 0.7 0.9 1 NPT 2.50 16 2.9 25 NPT 64 0.7 0.9 2 >< ½ NPT 2.75 1.7 4.0 50 15 NPT 70 0.8 1.2 2.75 1.7 4.0 34 'WI 20 NPT 70 0.4 1.2 1 NPT 2.75 1.7 4.0 25 NPT 70 0.8 1.2 21/2 X ½ NPI 3.00 2.0 5.7 65 15 NPT 76 0.9 1.7 3.00 2.0 5.7 44 NPT 20 NPT 76 0.9 1.7 1 NPT 3.00 2.0 5.7 25 NPT 76 0.9 1.7 C JOB/OWNER System No, Location CONTRACTOR Submitted By, Date ENGINEER Spec Sect_ Approved - Date Para www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 vicTAuLlo COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA pFI r \6taUIIC in 91 1 S Vic®-End II End of Run Fitting SERIES 67 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. S WARNING A A WARNING This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Company, P.O. Box 31, Easton, PA 18044-0031 USA, Telephone: 001-610-559-3300. 11 Ill liii till Iii IllItIllill IllillIfil 1111111 WCAS-7GNF4Y For complete contact information, visit www.victaulic.com 10.21 3209 REV D UPDATED 712008 Ix. A—c—t a —U1 ii 0~ VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 vicTAuLic COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA in 91 S DIMENSIONS Style 744 Sizes 2 8 (50 200 mm) ANSI Class 125 and 150 Elange P3ot Cmy areA of mlinC fi must be free from gr:qe, undulations or deformities of any type fortfrective sealing SPECIFICATION SECTION 2.2K 1 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 1O.OJ OTMti0' ISM IS09MI CER7REDCMAi4Y Style 744 FireLock® Flange Adapter with Vic-Plus Gasket System ret System PATIPD PRODUCT DESCRIPTION Style 744 FireLock Flange adopter is designed fOr directly incorp6rAting flanged components with ANSI CL 175 or CL. 10 bolt hole patterns into a grooved pfpe system f7S 7 8"(5o 200 mm) are hinqed [Qr easy handling with integral nd tabs Which facilitate as&rPbly, The design incorporates small teeth inside the icey shoulder I.D to prevent rotatiOn, Because of the .outside" flange diméiislon, FireLock Flange adapters.stiould not be used on FireLock fittings When wafer or lug type valves are used adjoining a Victauihr' fitting cherk disc dimensions to assure proper oearance, FireLock Flngadapters should not be used asanchor points for tie-rods across nonretrainedjbint Mating rubber faced flanges. valves etc.. require tire use of a FireLock Flange washer lweLock Flange adapters with Vic Plus gaskets do not require lubrication The gasket must always be issembled with the color coded lip on the pipe and the other lip facing t m he ating flange Style 744 FireL.ock Flange Adapters with the Vic-Plus Gasket System are designed and recommended for use ONLY on fire protection systems Vic-Plus Gasket,System: Vlctaulice now offers a gasket srsteir which roquu c no field lubrication on wet olpo systems The Vuc System (steritcd) is dry, clean and rior tox' It reduce-, emt)y time stibstannaity and eliminates the rne&s and chance of over-lubricalion Please refer to the latest copy of the Victaulic Field Installation Handbook (I-100) iorsupplemental lubrication requirements.. See V,ciauilc publication 1 0:01 fôrdeteds. Sealing SUttae. Dimensions Pi Size Mat Work MaiL End h1ape _eskmi__ - In - Apni. Wgt Actual Nominal Outside Press Load' No Bolt Each Diameter Diameter PSI Lbs Bolts t Sim; A 'B' U3s kihun lninin kPa N Reql. tnche Max; Mht W ) V 1 kg 2 2375 175 775 ni 341 675 600 4Th &75 27 SO &no 0200 ..150 s.., 2'1z 2.$75 175 1135 . ,X 37 288 3 9l 7 8 7,60 550 088 4.2 65 73,0 i o > 3 3.500 176 1666 - 3.60 4.53 H 7.50 6.00 0.01 1 so 00 115. 214 191 152. 24 2,2 4 4,5"-,Q 7Th 2780 . aX3 4 f0 5.50 9.i4 0.0 7.50 0,4 7.1 100 1,n '2U) 1045 1 , .24 3.2 5 5553 115 4350 5.56 6,71 11.00 lQ0Q 850 1.00 83 125 147 200 111920 Si 6,65 175 6030 , 6.53 1.70 12.00 11.00 9.50 1.00 . 9.3: 150 ill 720G 26040 lea it8 705 279 241 25 42 84 112 175 10219 8 . .. ,4.XS.I2 07 994 14,93, 13,50 1175. 1.13 139 200 o: 211 252 31? 341 298 211 'Refer to notes below. I r wi h1 ,uilror ROx refiw rrovCrthflVoiI I t II je ontalon tarfj4r holi ira r rM whan Vic-Flange adapter is utilized with walt-cype valves. 4 NOr avadbie with Vic-Plu gasket System Lubrication is required. NOTES Working Fyessuro and End Load are totti from allinternaland external loads based on standard weight steel pipe standard roil or cur grooved in accordance with Victeuluc spec 1cnrioos Contact Victautic (or perlorui rica cii ciber pipe WARNING! FOR ONE11ME FIELD TEST ONLY. the Maximum Joint Working Pressure may belncreasex1.to..1Itimes the rigures'thown: Style 744 Firei..ock Flange adapteis provide rigid joints when used on pipewith standard roil or ctiL'uuve dinieriions and consequently alluw no linear or ancjular.muvemenl atihajoirm . . . - WARNING: Depressuri.w and drain the piping system before attempting toms removeorecust any Victauilc'piping products. a REGISTERED TIW)EMft.Rl( Of VICTAUUC C COPYRIGHT 2OG4.U1CTAUUC:- PRINIEDINUSA. 1477 REV Victatilic Company of America • Phone! 1-800-PICK-VIC. (l-800-T42-5842) . Far 610250-8817 • eniail;piclwic©victauHc.com. Vichuire Company of Carede • Phonc 90 884 7444 • Fax 5105 884 ''74 c rrcfl iiçm diictuh corn Viclauuic Europe • Phone 22 9-381 1500 • Fax 22 9-380438 • e-marl;viceUcarctaUIe Viclaulic MiericaLaftna • Phone 610 5o9 3300 • Fax' 610-559-3608 'a maiL vrcal©vlctaulic.com victaulicAsia Pacific • Phone -6235r3035 9 Fax 6S-623o-035 • e-mail vicapNIctaul- 50110 \/ctaUIic urj 0MU I i'jii VIC-FLANGE ADAPTER NOTES I The Style 74 2 - 8/50 200 mm) design incorporates small, teeth inside the keyshoulder I.D. to 0 prevent rotation. 2 FireLock Flange adapter should not be used on FireLock fittings, When wafer or lug type valves are used,adjoining a Victaulic (Rung, che<k disc dimensions to assure proper clearance, 3 FireLock Flange adapters should not be used as anchor points for Ue rods across nonreslralnedjoints Mating rubber faced flanges, valves, etc. require the use of FireLock: Flange washer. 4 Area A-13 noted in the above drawing must be free from gouges undulations or deformities of any type foreffective sealing. s FireLock Flange adapter j keis must always be assembled with the coHr coded lip on the pipe and thp., other lip .f ing the meting flange. e Flange Washots: F ireLock F tango adapte rs rhquire smoolh hai (1 Mfl race at the mating flongd. lace for effective sealing Some applications for which the Vic Flange adapter is otherwise well suited do not provide an adequate mating surface In such cases it is recommended theta metal Flange West r be inserted betw on the Fire Lock F lange ridrq ter and the mat ing, flange to oovidt. the necessary sealing surface. Iypir.al npplirstinns whre a Fbmje Wesher shot ild ho tisd era: A When mating to a serrated flange: a standard flat flange gasket should be used adjacent to the serrated flange and then the Flange Washer Is Inserted between the FireLock Flange adapter and the flange gasket. B When mating to a wafervalve where typical valves are rubber lined and partially rubber faced (smooth prnot) the Flange Washer is placed between the valve arid We Frebock' Flange adaptor. C. When mating a rubLer faced flange the Flange Washer Is placed between the FireLock Flange adapters and the f UbbOr faced flanqe D When mating AWWA cast flanges to IPS flanges:. the Flange Washer is placed between two FireLock Flanges The hinge points must he oriented approximately 90* to each other. It one flange Is not a FireLock Ha ige adapter (eg flanged valve) then a standard flatfiarige gasket must be placed adjacent to that flange and the Flange Washer inserted between the flange gasket and the FireLock Flange adapter.- E When mating to components (valves, strainers, etc)whOrä the component flange race has an insert: follow, the same arrangement as In Application 1 F When: mating to a Series 705-W Butterfly vlve Style 744 may only be used on one sfdeof the connection, When ordering Flange Washers alwøysspedyprociuct spy (S 44)ands1ze to,assureproperFIlsrige,Wherissupplled MATERIAL SPECIFICATIONS Flange Housing: Ductile irOn colforming to ASTM A-526 grade 65-4$12 Ductile iron conforming to ASTM A-395, grade 65 45 15 is available upon special requqst. Coating: Black enamel •• OpftonaI Hot dipped galvanized Bolts/Nuts: Supplied by installer Gasket Grade "E" EPDM -Type A Vic-Plus Gasket System A (Violet color ode) F raLock preduc Ls h4vo been Listed by Underwriters Laboratoites Inc.Md Ap- proved by Factory Mutual Research for wet anddry (oil free Sir) spi inkier serv1ce up to the rated work Ing pressure using the Grade 'E" Type A Vlc Plus Gasket System requiring no field lubrication for most installation crindlUons AStsndard gasket rpprrwad for dry pipe systems to -40F (-40'C). Bad on'epicar pipe surface conditions, supplemental lubricant a recommended foi ericer nttalIed belowOF 08 *0 and for all dry Ripe 5yster or y' temeto be subjected to air tests prior to being rifled With wMer. Supplemental lubrication they alsO berquirtd on pipe with raaecl cx undercut weld seams cx pipe that has voids and/or cracks at the weld seams. C This product shall be manufactured by Victauiic Company. All products to be installed in accordance with current Victaulit installation/asseinbiy tnstoitibns. Vuctaulic reserves the right to change product specifications. designs and standard equipment Without notice and without incurring oblltItns Style 744 FireLockO Flange Adapter STYLE 741 12° SIZES STYLE 741 14 - 240 sizrs II StYLE, 743. L] I IL1I\1 om, I iuii Vic-FlangO Adapters SEE VICTAULIC PUBLICATION MOI FOR DETAILS STYLES 741 AND 743 Style 741 1. Style 71 Vic-Flangeadapter I, designed for directly incurpoia titig flanged counponents, with ANSI CL 125 or CL 150IPNIO and PN16 bolt hole patternc into a grooved pipe system. Sizes —12'/50 - 300mm are hinged for easy handling with integral end tabs which facilitate assembly Sl7s i4 24/3b0 600 mm a re cast in four (4) identIcal segments which are rfltetcoiiry clad aSassernbly is comp' iOd The design Incorporates small teeth Inside the key shoulder LD,.to prevent rotation (excluding 159mm size) These teeth siioi.ild he removed When Vie Flange adapter is utdizri I with a VIctulic Series 700 grooved end butterfly valve SCh'fUlc 5 pipe or plastic pipe. Vie Flange adapters may only be used or Vic -3000 butterfly valves on one side in 2— 8'150— 200mm sizes They are not recommended for 10 and 121250 and 300 mm sizes. VkFlange adapter Style 741 is not recommended for uwith Vietaufle Series 709 hutterffvvahs (contact Victaule for recommendations) rhey may only be çised on one Side of Victaulic Series 700 butnrfiy valve sers 2 — 100 mm fitted with standard or lever fork handles Vic-Flaripp adapter mast be ass rnlUed soil does not inLeiierp. wfli handle operation. Style 743 Vic Flange Style 743 flange lo-groove adapter permits (Tact connection of ANSI Class 300 flanged components into a grooved cvstem The two piece hinged housing engages into the pipe groove and bolts directly to any standard Hanged component. The conventional bolt hole pattern allows for casy, fast assembly. Style 713 rotates 3601 for moper a'igflmrit at bolt holes 0efwQ ttit ring Vic -l- !anpc gaskts utilize the Vitaulic pressure-responsive design. sealing on the pipe end and drectIy to the opposing flange face. No standard flange gasket is reuired. Style 743: Isdesigned to mate. with raised-tuna Ilancas, but can be Used with flat-face flanges by removing the raised projections on the nutsda face of the flange VIC-FLANGE NOTES Because Of the outside flange dimension, Vic-Flnge toutd Oct be used within 90° of one another on a standard fitting. When wafer or lug-type valves. are used adjoining a Victaulic fitting, check disc dlrflnsions to assure proper-clearance, Vie Fiange adapt troulU no is. used as enohur points for trs-tmts across non restiained iuints., Maurg rubber faca,td 1!4riges vuivs'eb,,, ialUiis tire usu of r Vie-F louge wasliei Vie Flange gaskets must always be assembled with the color coded lip on the pipe and the other lip facing ti le mating flange. JOB/OWNER CON TRACTOR ENGINEER System No. Submitted By 'Spec Sedt Para_, Location Date Approved Date______________________________ www.victaullc.com V1CTAULIC IsA REGISTERED TRADEMARK OF VICTAUUC COMPANY, 020ns V1CTAULIC COMPANY, ALL RIGHTS RESERVED. PRINTED IN THE lctaUlic° 0tH r nc na 'I CARBON STEEL PIPE — GROOVED COUPLINGS bt-Pl IUN ZjtzU hUN 2.Z.11% Ub.%. b STYLES 741 AND 743 MATERIAL SPECIFICATIONS Houing Ductile iron corrforrning to ASTM A-536, grade 65-4542. Ductile iron conforming toASTM A-395, grade 65-4545, is aVailable upon special request. Housing Coating slack enamel. Optional; Hot dipped galvanized and others. Coupling Gasket; specify ciiptce) Grade "" EPDM EPDM (( n color code) lCmperature rangc 30 1 to ~7 30 I [-34°C to iiO°C Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/ NSF 61 for cold +86l I+3000 and hot +180°F/+820C potable water service NOT RECOMMENDED FOR PLIROLEUM SERVICES Grade "T° nitrite Nitrile (Orange color rode) Temperature range —20F to +180 FI-29°C to +82°C Rcomrncnded for petroleum products, err with oil vapors, otable and rnIeraI Oils within the Cpccil cd crnperoturc rimiepi except hot dry st oir t140 Ft 600 and w nc over i ISO IF +66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. Services listed are General Service Recommendations only. It should be rioted that them are scrvicr s for which these askc:As are not rccornrncn ci Reference should always be made to the latest VlctaUllc Gasket Selection 'Guide for specific gasket service recommendations and for listing of services which are not recommended. Draw Bolts 14— 20350 6()0mm orb;,: Heat In st I plated carbon steel, trackhead mesh the physical and .hamic! requirements olASTMA-449 and physical requirements of ASTM A-183 www.vlctaulic.com VCTAUtjc IS REGISTERED TRADEMARK OF icrAuuc COMPANY, 02006 VICYAtJUC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE US tic tic • Jctaukcr ecu rt fl CARBON STEEL PIPE * GROOVED COUPLINGS SI-'EUIbIUAI ION SbU I ION 2.2.K Ub.Ub STYLES 741 AND 743 STYLE 741 Sizes 2— 12750 - 300mm ANSI Class 125 end 150 Flanges Size Plessule L d No. Bolts i solt Size t InchesInim Dimensions - Inches/nim Wgi Each :r klil— 11 2 13.'6,75 V 4.75 7c 50 5920 57 172 3 121 .iA 2.375 3 3 75 D1S3O 5 43 65 t3 3 ... 2.58 4 i .29 S 600 ui 53 80 88.9 89 H 211 91 152 34 24 cc 7 8 °° ° ° 74 100 5143 5 111 251 '219 191 34 ,5 3½ 5.5s 8 '5.' x 830 : 8.6 125 1413 .-. I itco i x' 216 39 S .so 'x S0 1683 2 '5 14*34 ios 11)8 302 L79 41 25 45 165.1 MM 85(X) 300 9,960 50 7E 1192 100 945 1(X) lOLl 1551 21155 44320 365 193 303 279 240 9S 43 8 625 1450 1 16C OO V'l 1i 13 368 1 14 r 'Ill 9.. '3 19 2141 75 10 10i0 300 12 12 % 4 J S l4.S 250 273.0 2CI65 121110 273 313' J 438 4CÔ 361 30 12 12.750 300 3S75 2 1275 1431 2025 1900 17.00 125 46.8 300 323.9 2065 170270 354 54 45 43232 211 Workfng Pessiiie aea LdLoid atetotal,. from ali eternal and eetereI loads, bed cn eridardveehjht cee pipe. ..uindcrd roltor cut jroovedin accordance sVILh viCtaulic spOC1' auons Conuct Vic i iullc for pci Ion i ri a no on other pipe WARNING FOR ONE TiME FIELD T EST ONLY, the Maximum Joint Working Pressure may be increased to ½ times the figures shown 11QtaI bolts required to be supplied by installer, maybe ordered from yictauUc IMPORTANT NOTES: Style /41 Vic , liar adapters r gld Joints hj3 used on pip ith standaid cut or roll giu.i' rJinn rlslOn 3nd 111 .quent1y allow o linear or angular movement at the taint When used with Victaulic Scries 700 buuerils saves phttk pipe or light wall rnotallic pipe, srn il trth in D of Lay section should be removed and may be used on one side of the valve. Contact Victaulic for inlbrmmion on AS212 - 1eh C ISO 2084 (PN to), DIN 2532 (PN10) andJ B-2210 (30K) fianges II Shaded amea of mating We must be free Iom qouges, undubtiens 0rd8bnin1im daisy type for eflëctive 5e21fnr3. Ek'a&eiatoJ tot Cia n7y S Www.vlctaulic.com VICTAULIC 15 A REGISTREDTRADEW1RK OF V1CThUUC COMPANY. 02006 VICTAUUC C0MPAN5, ALL RlGNT5RESERVE0 MINTED IN THE USA. XA—W—Uhd CARBON STEEL PIPE - GROOVED COUPLINGS FUIbIUA I ION ShU I ION 2.2K UbUb STYLES 741 AND 743 DIMENSIONS STYLE 741 Sizes: 50 -.300mm/2 - 12* PN10 and PN16 Flanges urlJ1II eJ) çu 03:l: Lie .310 ltj, 10e: .Ye .1 d1 50 603 4 16 36 4561 4 el 87 177!65 120 14 2 2375 145 j640 230 1025 238 .41 6075.50 4.920.79 Li 761 illm 4 6 16 275 4 16 c ItS 65 * i0 21 31000 145 Zo 1 105 6025 8 16 31. 83 405 115 / 4S 116 200 0 1 160 22 42 24 88.9 IG 6210 8 16 16 3 3.500 145 1395 230 2330 3.50 4.53 833 7.87 6.30 ON 314 too 1343 10 1Q260 8 16 16 16420 8. 16 114 341 21 1 229 150 24 4 4.500 145 '05 230 3590 4.51) 5.55 9.88 901) 1.09 04 717 19mm 1590 10 -00 16 00 8 20 159 181 .5 241 ' 4.5 6.250 145 ---) 400 230 7056 625 1 7.36 1° itO 6.45 1.02 11)0 163.1 mm 1651 10 16 34294 20 165 t I 300 280 ~46 75 -.3 6.500 145 4811 - 230 7632 - - 6,60 748 11193 3100 945 J LOO 100 150 168.3 30 32250 16 35600 168. 190 1 302 279 240 2$ 45 6 6.675 2 145 tO 5000 5) 8 230- 16 8000 c 0 8 I) .20 20 6' 7,78 J 11.89 10.98 2 0 945 toO 5 oqi TO.O 200 8 250 8.65 273.1) 345 io 8470 230 55 16 saso 12 1 20 12 2 4 27 313 437 3955 3505 275 11.0 10 10.750 145 13160 230 21055 10.75 12.31 17.20 15.55 13.78. L 24.2 300 323. 10 82)71) . 16 131810 324 365 478-i 460* 4004 324 3714 12 32750 145 18510 12 20 230, 12.75 1431 k S llI 1575 726 38.4 Working Presstire and End Load are total, from at Intel nal and eKro1n/ loads,based.: óAstañdard welqhl steel pipe, stanciatd roll or cut grooved In accordance with vlctaulic sp ficatlons. contact Victaulic tbr perform once- on other pipe. WARNING FOR ONETIME FIELD TEST ONLY the Maximum Joint Working Pressure may be increased tot ½ times the figures shown FN1L d1mncfriris (rnrn/lrrrhc) W1F.O/1437; 1( 40/fl.9; V =20J11.F1;.7 O/1.1R § PN16 dimensions jrrm/lnches:W 438/1724; X406/15.98 Yz 162/14.00; 2 30/1, 1 f PN 16 dimensions qnmflnthestiW = 478/18,82 44/1.11;- 410/16,14; Z- 32/1 26. 1' Total bolts required to be supplied by Installer. Bolt-sizes for conventional flange to fi ange connection Longer bolts required when flange utilized with wafer-type valves. IMPORTANT NOTES Style 741 Vic-flange adapters provide rigid joints when used on pipe with standard cut or roll groove dImensions and consequently tInw rinllnar nr arq ilar rnnslrmpni at thnjoinr Whpri-ri*rl iih Virra:ilic--Srips 700 Hitlrtflyrlalvcc pLs.tk rule ar hc,h' wall mllEc pipe, small teth In ED ofkey secUo should be removed and may only be used On one ad 0flh'vOFtP Ce 11er ctou IC ks infomlatlo3 on s219 labte I O 2084 PN10 DIN 2532 (PN10) and AS B2210 (10k) flanges. C Shaded area Of m91109 fce must be free from gouges, undulations or defbrmltles of any type fo'r effective sealing. www.vlctaulic.com VICTAUUC IS REGISTERED TRADEMARK OF VICTAUUC COMPANY,'Q 2006 VICTAIJUC COMPANY. AU. RIGHTS RESERVED. PRINTED IN THE us flC tu A Atmu -I, d VC11 c S JOB OWNER System No. CONTRACTOR ENGINEER Submitted By Spec Sect___________ Para_________ SFEUlblt.A I ION 6EU I ION 2.2.K Reducing Coupling <> ' SEE VICTAULIC PUBLICATION 1041 FOR DETAILS STYLE 750 The Style 750 Reducing Coupling permits direct iedddl ion on the piping run. Designed to replace two couplings and a reducing fitting, the Style 750 features a pecIat reducing gas1et for pressure resionive sealing. A steel washer which prevents telescoping of the sriialler pipe it isle the 6- pipe duriugver Ucal systems asseiriLily is available upul I rquedt. Exaggerated forclsrily MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ATM A-536, grade 65-4542. Ductile Iron conforming to ATM A-395, grade 65-4545, is available upon special request. Housing Coating. Orange enamel Optional. Hot dipped galvanized and others Gasket: (Specify cholee: Grade "E" EPDM (All other sizes) EPDM (Green color code), Temperature range -317F to +2OFI-34°C to +flOC. Recommended for cold and hot water service within the specified temperature range plus a variety of diftite acids, oil-free air and mat' chemica' services. UL classified n accordance with ANSI/NSF 61 for cold +86F/+30C and hot -i-180°F/+82C potable water service. NOT 1Lc;OMMF NOED FOR PETROLLUM SVICES, Grade T' nitrile f'itrie (Oang.coloi code), Temperature ran3c_20'Fto+180F/_,29*CtQ +82*0. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature rangn Not recommended for hotwaterservices over. +150*FI+6600 or for riot dry air over 40*F/60C sprvicesllsled are General Service ltecommerrclatlorls only.,ltshoukl be noted that.there are services for which thede gaskets are trot recommended. Reference shouicl always be made to the latest Viclaulic Gasket Selection Guide for specific gasket service recommendations and for a listuic of sai vcOs which are ro .t recommended, Optional: Asserhl$y Washer: Galvanized, carbon steel BoltslNuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A483. Location Date Approved Date________________________________ www.vlctaulic.com '\t1auIicr V1CTAU1tC IS A REGISTERED TRADEMARK orvlclAuuc QMPANt o 2ocisvrcrAuuc COMP Au. RrGNTS gtsceveo. PiNTEo 4 THE USA. nc-i, U flc no 'I 0.16 14 0.16 14 0.13 0.13 11 _________ 003 2-½)3 It T _____ 0.28 JA 25 0.18 2-x3t 2S 0.2$ 25 A 10 &93 5S3I1$ ? 4 25. 465 154 2 168 48 475 70 - 154 222 151 45 475 703 1 124 151 47 is 723 121 625 &5o 2.25 .22 853 .i-. 59 226 7 .02 693 225 122 625- .3 8.90 57 2.25 120 276 57 5i 1i.70 -.13 282 27 5 853 11.90 22557 72 332 .3i I )i.90 225 211 1 502 '57 I fl'7 725 tflO CA 0'- 5 o 0'.-47' 0'- 47 0'- 224 2,22. 155 188 2.0 32 48 5.1 2.4 .4,8 2.1 4,9 22 43 2.0 43 1.9 80 3,7 8.6 3,9 62 3.0 69 3,1 5.1 16.7 78 1 ,9 5.9 153 IRS CARBON STEEL PIPE - GROOVED COUPLINGS rL,lrIL,M I upi IL)IN .r\ UbI(its Reducing Coupling, SEE VICTAUUC PUBLICATION 10,01 FOR DETAILS STYLE 750 DIMENSIONS 2 r OX X 2410 445 ½ "5O 9-OW -- 2420 4150 0-1,8 _ 2½ 2 5100 2215 0-047 65 90 3450 9850 0-18 550 0-007 752ñm x 2 350 50 2410 M. 0-1.8 2 350 1550 0-907 59 240 69 W 0-1,8 - 216 SOD 3250 0-07 8 84M x 760 mm 0.-o01 - 4 2 350 1550 0-0.33 100 X 2 1 350 2275 63 7410 10125 0 - O.B 0-3,2 4810 0-0.13 S 500 5450 21409 0-32 1143mm x 745.1 MM 350 22ii 0-013 2110 10125 6-12 0-0.13 S 4 355 IS io& 2410 247. 0-32 6 , 4 350 5565 0-0.13 1 50 ' 273 2420 24724 0- 12 5 320 8503 5-0.13 125 2410 37825 0-3.2 5.2mm g 4 350 5557 0-003 410 24757 0-3;2 I 20D x 150 1 2410 53AW -0 o-3'( Il_lxsLH'; H Refer to notes on back coves Style 750 Reducing couplings should not be used with end caps (#60) In systems where a vacuum may be developed Contact \flctutic for detaIls lot www.vlctaulic.com VICTAUUC IS A REGISTERED TRADEMARK OF VICTAUUC COMPANY C 2006 VICTAIJUC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USk AtstaUIIC nc no n ac., LI S IPS CARBON STEEL PIPE—GROOVED COUPLINGS 'jl`tUlhUA I IUN U I ION OEM Reducing Coupling SEE VICTAULIC PUBLICATION 1001 FOR DETAILS STYLE 750 FLOW DATA HEAD LOSS The head loss across Style 750 Reducg courlfrg is very small and Is essentfally te saineas for standard shod burly cedudng Pipe 1ttiris. Equvalertt lengths of standard weight steelprpe are shown in the tables. All data is based on water flowing at amblenttemperatur& FLOW REDUCING FLOW EXPANDING 1F - 2 5,9 2 27 50 25 1 E 20 5 54) 25, ½ 2 5 - 65 X - X 65 50 i6l mm ee 09 to cx x 4 15 1flfl1 X &2rnlTI I4mm x 761rnrn 3 4! >c 5 '4 3 L) r 4 5 23 C) 23 5 .4 50 5 45 2rnm 4 X 5 5 2_I $ 6 6 5 )50. 2.2 iSO 203 I www.viciauflc.com VICTAULIC IS A REGISTRE0 TRAOEM4R4 Or50CTAUUC COMI- * I-ow V1CTALLIC COMPAN IkI4TS RESEIWED Pf4ITD \4tUIicf ILJIN oc., I iji'i Reducing Coupling SEE VICTAULIC PUBLICATION .4041 FOR DETAILS STYLE 750 GENERAL NOTES Working Pressure and End Load are loud, From all internal and external loads, based on standard weight (ANSI) sleel pipe, slndaid roll of cutrcovud ill accordance with Victaulic, specifications Contact Victaulic for performance on other pipe Maximum working pressure rating based on larger pipe sizo Maximum End thad rating based on smaller pipe size WARNINP FOR ONE TIME, FILDiEST ONLY, the: Maximum Joint WorJng Pressure may be. increased Lq 1½ times We figures Shown, t Allowable Pipe End Separabon and Deflection figures shoW the maximum nominal range of movement available at each joint for standard roll grooved pipe Figures for standard cut grooved pipe may be doubled. Those figures are maximums; lot design and Installation purposes these liguresstiouid be icriuced by: 501110 for .)r 3 1MV0 —90mm; 25% for 4/ 100mm And lerer. .. Number of bolts required equals number of housing segments. Metric thread We hole, are avar a i ((c. or Codedgold) for all c,eupllrig sties upon request. Contact Victaulic for details. WARNING: Deprecsurize and drain the piping sysrn before attompting to Install, remove, or adjust any Victaulic piping products. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be thanufactured by VictauIiortn VictaullC spec:ificatione. All prbductste•be installed In accordance with cui rent Victedic itaIlatonIassernbly iiistruetio.iir, Victaulic reserves the light to change product spec ii catioris, designs and standard sqn pnierit without notico and without I Incurring obligations. US & WORLD HEADQUARTERS CANADA CENTRAL AND souTh AMERICA P0 Box al 905-8&1-7444 1 610-559-1,100 Easton, PA 180440031 USA 905-884.-9774 (fax) 1.610-559-3608 (fax) 4901 Kesslersville Road viccanda@victauliccom vicaI.@vlctatiiiccorn Easton, PA 180.40 USA EUROPE ASIA PACIFIC 1-8WPICK-VIC (1800-742-5842) 329-3814500 8621-54253300 1-610-559-3300 329 8044-38 (fax) 862154253671 (fax) 1610-250-8817 (fax) viceurovicluIicb Vap@victcitrlfceom .pickvlc@victaulic.com www.victaulic.com UNITED KINGDOM MIDDLE EAST 44(0)1438741100 . 9714'883-8870 44 (0) 1438313883 (fax) 97i-4-883-88 60 (fax) WCAS (QA5LJ viceuro2victaulpc,be UPDATED 6/2006 0608 1536 REV ii actauIi V1CTAIJUC 1$ A REGISTERED TRADEMARKOFVICTAUUC COMPANY C 2(6"/lCTAUUC COMPANY,ALL RIGHTS RESERVED PRINTED IN THE USA. r a D Dia. H 83132W-I thru 1112 B3132W-3/4 6 PECIFICATION SECTION 2.3 Fig. B3132 - Two-Bolt Underground Clamp (TOLCO Fig. 9) Size Range: 4" (1 00mm) thru 24 (600mm) A.W.W.A. pipe Material: Steel Function: Clamp is used for underground A.W.W.A. cast iron and SA~- ductile iron water pipe to prevent joints from separating. The O.D. of the A.W.W.A. pipe is shown in the data table. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Bolts and Nuts Included Order By: Figure number, pipe size and outside diameter of pipe. Order B3132W lugs, tie rods and hex nuts separately. Pipe1: A B Clamp I.D. Steel Size Approx. Part No. in. (mm) in. (MM) in. (MM) in. (nim) in. (MM) Bolt Size Lbs. (kg) 83132-4 4" (100) 12/8' (3270) 93/4 (247.6) 5 (127.0) 1 /2"X2' (12.7x50.8) 5/8 %11 x3" 864 (391.9) B31326 6 (150) 14Wi3746i 12 (3048) 7V16' (1794) W'x2' 112.75508) Ia'11x3" 1020 (4626) B31328 8" (200) 171/4" 1 (438.1) 141[ (361.9) 9/16 (233.4) 1/2"X2 112.7x50.8) /81-11 53" 1222 (554.3) B3132-10 10" (250) 19/8' 1 (492.1) 161/2" (4191) 11I8" (288.9) 1/2"x2' (12.7x50.8) /8"-11 x3" 1409 (639.1) 83132-12 12" (300) 21/t' (555.6) 18/t" (479.4) 131/2' (342.9) 4000) 1/2"x2' )12.7x50.8) /4 x3 (190x762) /8"-11 x3" 1608 (729.4) 83132 14 14" (350) 26" (6604) 228/4 ' (5631) 15/4 7/ 9x41/2 4359 (19772) 83132-16 16" (400) 28/8" (720.7) 24/8" (625.5) 17/8" (454.0) 3/4" X 4' (19.0 xl 01.6) 18541/2 6403 (2904.4) B3132-18 18" (450) 313/a" (7969) 275/a (701.7) 201,(5080) 3/4' x 4 (190 xl 016) 11/C-7 x 5 7293 (3308.1) 83132-20 20" (500) 331/2' (850.9) 29/4' (755.6) 221/8' (562.0) 3/45 411211 (19.0 xl 14.3) 1114_7 x 5" 8778 (3981.7) 43132-24 24 (600) 39' t990.6 351/4U (895.3) 1669.91 -, 3/4"X5" (19.0 12Th) 11/4 6X5½ 11659 (5288.5) Fig. B3132W - Lug Washer (TOLCO Fig. 9X) Size Range: 3/4" (20mm) thru 11/2" (40mm) rod Material: Cast Iron Function: Used with B3132 to secure tie rods. The projecting lug bears against the clamp bolt to prevent washer and tie rod from slipping off clamp. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size and finish All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PP_ 00 COOPER B-Line Size Range: /-16 rod thru 1/213 rod Material: Steel Function: Typically used to suspend pipe from wood joists. Machine threaded on one end and lag threaded on the other end. It is recommended that pilot holes be pre-drilled to preven beam from splitting and to aid in starting lag threads. Approvals: Conforms to the requirements of NFPA13. Finish: Plain. Contact Cooper B-Line for alternative finishes an materials Order By: Figure number, rod size, length and finish SPECIFICATION SECTION 2.3 -- Ground Level Under Ground Pipe . Fig. B3214 - Tie Bolt (TOLCO Fig. 106) Material: Steel Function: Recommended for securing the connection of steel pipe to ductile pipe first attach tie bolts to pipe flanges then connect tie rods. May be used in vertical or horizontal applications. Approvals: As shown in NFPA Pamphlet 24, Installation of Private Fire Service Maintenance 4 (1 00mm) - 12 (300mm) pipe size. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, length and finish. Custom lengths for thicker flange available. 12 Length Approx. Wt./100 Part No. in. (mm) Lbs. (kg) l83214-4 I119 L-11 toll!i8i - 3/4" (19.0mm) Wa. Steel Pipe Riser - Adapter - All Threaded Rod Ductile Iron Riser Typical Application Size Specify 4" (101.4mm) or 41/2" (114.3mm) 1" (25.4mm) Max. fl . Fig. B3213 - Coach Screw Rod (TOLCO Fig. 105) x 31/2 and /2 x 31/2 will have a coach screw thread length of 2' (50.8) and a rod thread length of 1 (25.4). Design Load is based on proper installation and solid wood. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line I SIGMATM Quality - Service - Commitment - Delivered. SPECCAflON SECTION 2.3 40 1 - - -.... ----------------- -.- - 2- 481n Full Body Mechanical Joint Fittings MATERIAL: Ductile Iron ASTM A536, Grade 65-45-12, 60-42-10 or 70-50-05. PRESSURE: 350PS1 WATER WORKING PRESSURE (CLASS 350) 2" - 24" and 250PSI WATER WORKING PRESSURE (CLASS 250) 30" - 48". TESTING: In accordance with ANSI/AWWA CII0/A21.10 & UL- FM requirements. LAYING LENGTH: In accordance with ANSI I AWWA C110/A21.10 DEFLECTION: 2"- 4"=8°, 6"7°, 8"-12"=5°, 14"-16"=3 1/20 18"-24"3°, 30"-48"=2° CEMENT LINING: In accordance with ANSI I AWWA C104 I A21.4. COATING: Interior of fitting is seal coated (asphaltic material) in accordance with ANSI I AWWA C104 I A21.4 and NSF61 approved. COATING: Exterior of fitting is seal coated (asphaltic material) in accordance with ANSI /AWWA C11O/A21 10 and NSF approved. GASKETS: SBR in accordance with ANSI I AWWA C1 11 I A21.1 1. Also available in EDPM, NBR and CR. T-BOLTS: Low Alloy corrosion resistant high strength steel in accordance with ANSI I AWWA C1 11 IA21.1 1. APPROVALS: 3"-16" Underwriters Laboratories listed and Factory Mutual Approved. STANDARDS: Certified to NSF61 Standard ANSI IAWWA CIIO/A21.10 for Full Body Ductile Iron Fittings 2"-48" <*> (Th Note: 2"- 24" also available in Fusion Bonded Epoxy APPROVED M.mb.T : ... :5:•:. W,4 Fw S;i = INDEX BENDS 1/4 90° Bends 4 1/8 450 Bends 4 1/16221/2°Bends 5 1/32 111/4° Bends 5 90° Bends MJ X Flange 10 45° Bends MJ X Flange -- 10 Adapters: MJ X Flange 10 TEES Tees and Crosses 6-7 Hydrant Tees ___________________---- 8 MJ X Flange Tees ____________________- 8 CAPS AND PLUGS 11 WYES 450 LATERALS ___________________ 11-12 REDUCERS: XMR, XSPR, XLPR, XPPR - 9 C MJ X Flange Reducer ____________ _________ 10 Eccentric Reducer ____________________ 11 OFFSETS _-_-- 12 LATERAL WYES 13 SLEEVES: XMS, XML 11 XMML- - 12 CAPS AND PLUGS: XMK, XTK, XMP, XTP, XMMP 14 S Weights in pounds, less accessories/Dimensions in inches 2 1 SIGMA Corporation www.sigmaco.com 0.19 in. (4.E See Note k Ls T I OD PLAIN END bchanicaI Joint Details Bolts Plain End Details] Size A B C i5 IF i K1 K2 1. M N 0 P S X No Size Length OD Ls I 3 3.96 2.50 4.84 4.94 4.06 6.19 7.69 7.69 0.94 0.62 1.37 0.31 0.63 0.52 3/4 4 5/8 3.00 3.96 5.50 92 602 490 750 912 912 1000751500310750657/84 0.31 0.75 0.70 7/8 3M 350 480 550J 6 6.90 2.50 8.02 8.12 7.00 9.50 11.12 11.12 1.06 0.88 1.63 6 3/4 3.50 6.90 5.50 _i-,9 10 0-5 11.10 250 2.50 1017 1027 915 11.75 137 13.37 -112 ,-100 1.75 01 0.75 0.75 7/8 6-3/4-4.00 9.05 5.50 12.22 12.34 11.20 14.00 15.69 15.62 1.19 1.00 1.75 0.31 0.75 0.80 7/8 8 3/4 4.00 11.10 5.50 12 14 16 '13-2 0 15.30 17403501850 20 3.50 1432 16.40 1444 16.54 130 1625 174 1T88 125 tOO t75 L31 075 05 7/8 8 3M 4.00 13.20 5.50 1 6417542100 15.44 18.75 20.31 22562250 20.25 1.31 13813 1.25 2.00 060-31 0.31 0.75 075097 0.89 7/8 7/8 7/8 7/8 11/8 10 3/4 4.50 15.30 8.00 12 3/4 450 1740 8.00 18 19.50 3.50 20.60 20.74 19.64 23.25 24.83 24.75 1.44 1.38 2.13 0.31 0.75 0-75 1.05 112 1.22 1.80 12 14 3/4 3M 3/4 100 1.00 4.50 450 19.50 2180 8.00 20 2160350227022842174255027082700150144131 30.00 24 25.80 3.50 26.90 27.04 25,94 31.58 31.50 1.62 1.56 2.31 0.31 275 1 0.75 1.00 16 20 24 5.00 600 6.00 25.80 3200 8.00 800 30 3200400332933463217368839122181200 36 38.30 4.00 39.59 39.76 38.47 43.75 46.00 2.00 2.00 2.75 0.38 38.30 8.00 42 48 50.80 445040045794596446750625312531220020027503810019513!8 146.00 2.20 1 3/8 28 1IM 650 4450 4.00 52.09 52.26 50.97 57.50 60.00 60.00 2.00 2.00 2.75 0.38 1.00 32 1 11/4 6.50 50.80 8.00 <*>ti IIIIi. i Dimensions in inches Weights in pounds A SIGMA Corporation www.sigmaco.com 1 3 PPROVED p MJXMJ MJ x PE MJxMJ i LTA ira: kd~ 114 900 BENDS size MJxMJ DUCTILE IRON MJxPE DUCTILE IRON R T MJxMJ MJxPE Item No. A Item No. I B Wt. Wt. - 3 XMB390 XMB4901T.. 5.50 6 50 XME390 XME49OIE 13.50 1450 4.00 4 50 0.48 0'6 35 55 35 $0 6 XMB690 8.00 XME690 1600 600 0.55 85 80 87 XM8890T 9 00 XME890 -17.-00 7 00 0 O. 125 120: 10 XMB1090 11.00 XME1090 19.00 9.00 0.68 190 190 12 XMB129011 1200 XME11.29OT 2000_____ 10 0i 0 75 Z55 255::: 14 XMB1490 14.00 XME1490 22.00 11.50 0.66 340 325 6TXMB1690L _____ 1500 XME16902300 1250.0708430410TTT 18 XMB189O 16.50 XME189O 24.50 14.00 0.75 545 520 20 XMBZQ9O 18 00 XME2090 26 00 15 501 0 8 6so:T 24 XM82490 22.00 XME2490 30.00 18.50 0.89 1025 985 307T XMB3O9OT 25 00 XME3090 33 00 2150 1.03-,1 690T 1 585T 36 XMB3690 28.00 XME3690 36.00 24,50 1.15 2,475 2,310- .42- XMB429OT, 31 00 X1v1E4290T IXME4890 39 00.J 142.00 27 5oT -1-28 : 3,410-1 3,200 48 XMB4890 34.00 30.50 L4Z.... 4.595 4.330- 1/8 450 BENDS size MJxMJ DUCTILE IRON MJxPE DUCTILE IRON D ' - MJxMJ MJxPE Item No. A Item No. B Wt. Wt. j_. 3 XMB345 3.00 XME345 11.00 3.62 0.48 30 30 4 xMB445: 400 XME445 ______ 12 00_ 481E 0 52 50 45 13.00 6 XMB645 5.00 XME645 7.25 0.55 75 70 8 XMB4T S 50= XME8457: .13-15,0-- 844 06 iio i05.i 10 XMB1045 6.50 XME1045 14.50 10.88 0.68 155 155 12T)125T750 XME1245 1550 1325:075:215-215- 14 XMB1445 7.50 XME1445 15.50 12.06 0.66 270 255 16:.:xMB1645::8Q0 XME1645 16 00 1325 070 340' 320 .18 XMB1845 8.50 XME1845 16.50 14.50 0.75 420 395 20 xMB2o45:: 9S0______ XME2045 1750 16 88 0 80 530 500 24 XMB2445 11.00 XME2445 19.00 18.12 0.89 755 715 30 XM83045T 1 0= XME3045. 23 00 27 75: 1'03 1 380 1 275:: 36 XMB3645 18.00 XME3645 26.00 35.00 1.15 2095 1930 421 xMB4245:: 2f00_____ XME4245 29 00 42Z5 11.28 2 955 2 745 48 IXMl34845 124.00 IXME4845 132.00 1 49.50 1A2... 4.080 3.815 Weights in pounds, less accessories/Dimensions in inches 4 1 SIGMA Corporation www.sigmaco.com APPROVED Member "' I MJxMJ MJ x PE MJx MJ Mix PE I SIGMATM Quality - Service - Commitment - Delivered. 1/16 22-1/20 BENDS Size MJxMJ DUCTILE IRON MJxPE DUCTILE IRON R - T MJxMJ MJxPE Item No. A Item No. B XMB322 3.00 XME322 11.00 7.56 048 30 30 4 XMB422 -400-,X ME422 32 0Q 10 06 o52: 50. 45 6 XMB622 5.00 XME622 13.00 15.06 0.55 75 70 8TT XM8822 550______ XME822TT 13 50_.,. 17 62 002 110T 105 10 XMB1022 6.50 ______ XME1022 14.50 22.62 0.68 160 160 1221.2 xMB12221 7 50 XME1222 15 56--21-62--075-220-220 11 .2121 21 14 XMB1422 7.50 XME1422 15.50 25.12 0.66 275 260 16121 XMB1622 8 0Q_ xME1622: _____ 1600 27 62 0 70 45 325::T 1.8 XMB1822 8.50 XME1822 16.50 30.19 0.75 430 405 20_ XMB2022 9.50 XME2022_ 17 50 35 19 0 80.., 535_,. 505.,.... 24 XMB2422 11.00 XME2422 19.00 37.69 0.89 765 725 30T XMB3022 J-5,00- xME3622: 2300 578121 f-08-- 36 XMB3622 18.00 XME3622 26.00 72.88 1.15 2,135 1,970 42_ XMB4222 21'00- _.,.. XME4222_ - 2 8800 128 3020212 2810 4.._.... XMB4822 24.00 XME4822 32.00 103.06 142... 4.170 3,905..... 1/32 11-1/40 BENDS MJxMJ DUCTILE IRON MJxPE DUCTILE IRON - MJxMJ MJxPE Size R I wt wt Item No A Item No B XMB311 3.00 XME311 11.,QO 15.25 .ö48 30 30 4XMB411400_ _____ XME41l _____ 1200 203121052250 45 70 6 XMB611 5.00 XME611 13.00 30.50 0.55 75 8IJ XMB811 550 XME811 1350 355021 TO 110 105 10 XMB1011 6.50 XME1011 14.50 45.69 0.68 160 160 12211 XMB1211 7 50_____ XME11.121 1550 558121 0.75-2O21 220 14 XMB1411 7.50 XME1411 15.50 50.75 0.66 275 260 16XMB1611i1.,..800 _XME1611Ti60cL_.... 812107o:345211325::21 18 XMB1811 8.50 XME1811 16.50 60.94 0,75 430 405 2OEXM2011E950TiiTXME201C1750____ 7j0621080:540:21510.... 24 XMB2411 11.00 XME2411 39.00 76.12 0.89 770 730 3021XMB30312: 0021 :XME3olt:2300T22121 11675 1032 1410:% 1305 36 XM133611 18.00 XME3611 26.00 _____ 147.25 1.15 2,145 1,980 42121 XMB42II:.... 21 00.T21 XME4211 IXME4811 29 00 17769 1 2T. 3 03521 2 82521 48 XMB4811 24.00 132.00 208.12 12... 4.190 3,925 fl <*> Dimensions in inches Weights in pounds APPROVED _____I SIGMA Corporation www.sigmaco.com I 5 XMT mus XMC TEES AND CROSSES (continues on following page) Size si TEE CROSS ________ T Ti A B S Tee WI XTE Wt Cross Wt Run Br MJxMJ MJxPE 2 2 350 XMT22 0.45 0.45 5.50 5.50 3:21 3:12 3501 XE33 XMT33 -T XMc3312 Q'4812 0 -4Q5:50-"5'50- 11 13 50 S512 5521 70112 4 3 350 XMT43 XTE43 XMC43 0.52 0.48 6.50 6.50 14.50 75 70 90. 4 412123501 XMT44112 )CTE44211 XMC4421 05212 0 52: 650126 501 14 50' 8012 75111.112 105_ 6 2 350 XM162 0.55 0.48 8.00 8.00 95 61212 312 3501 XMT6311211 XTE631212 XMC63:12 05512 0482 80012 86012 1600 11012 10512 12512 6 4 350 XMT64 XTE64 XMC64 0.55 0.52 8.00 8.00 16.00 115 110 140 6 6........ 350 XMT66_. XTE66 XMC66.,..,, 055..,.. 0.55 8.00..,,. 8.00 16.00, 125 120, 160 8 4 350 XMT84 XTE84 XMC84 0.60 0,52 9.00 9.00 17.00 165 160 185 9--6 : 350 XMT86E XTE86 XMC86:12 06012 055:90012 9001170011 17512 17012 20512 8 8 350 XMT88 XTE88 XMC88 0.60 0.60 9.00 9.00 17.00 185 180 235 ,16-4- 350: XMT10412 XTE1O4:T1 XMC1O4I 06812 0 621 11 002 1100 19 001 a352: 23512 26012. 10 6 350 XMT1O6 XTE106 XMC106 0.68 0.55 11.00 11.00 19.00 250 250 285 10:12 8212 3502 XMT108' X1-E108 X '-C108-1 0 682 0 60' ii 00 ii 00. 19 00' 2601 2601 3102 10 10 350 XMT1010 XTE1010 XMC1010 0.80 0.80 11.00 11.00 19.00 310 310 380 12:4..T135o:xMT124TxTE124TxMc124:o7512o52: 1200: 200 2000 315 1514o12 12 6 350 XMT126 XTE126 XMC126 0.75 0.55 12.00 12.00 20.00 325 325 360 12TT8'T35oxMTj282xTE1281xMcj28To75"o6o 'U00 120z000'3401234012385 12 10 350 XMT121O XTE1210 XMC1210 0.87 0.80 12.00 12.00 20.00 390 390 466- 12-12- 135o.12xMT1212_xTEt12_xMc1212:o87o87_i2oo12oo2000 41012410149512 14 4 350 XMT144 0.66 0.52 14.00 14.00 384 1412:61121 3502 XMT146 XTE1461111 XMC146I 0 6E 0 55 14 oo: 1400' 22'OO' 435 " 4201247512 14 8 350 XMT148 XTE148 XMC148 0.66 0.60 14.00 14.00 22.00 450 435 500 14TT1o1:3so:xMT141o:xTE1,41o'xMc141oo66-o68'1400 1400:2200 4651450125401112 14 12 350 XMT1412 XTE1412 XMC1412 0.66 0.75 14.00 14.00 22.00 495 475 585 f4:12 141: 3502 XMT14I4 XTE111'41 xMc1414: 06612 0662 1.4 00 14 o0 22 0052Q12 50012 63521 16 4 350 XMT164 0.70 0.52 15.00 15.00 1612 6212 350: XM11612 XTEm8.1:12 R!1C166T 07012 055: 15 oo: 15 00 23 0'O' 5402 52012 5752 16 8 350 XMT168 XTE168 XMC168 0.70 0.60 15.00 15.00 23.00 550 530 605 1612:1o1:1235o:xMT161o:xTE161o12xMc161o:o7oLo68 1500 1500 2300'570,,.5501645,12 16 12 350 XMT1612 XTE1612 XMC1612 0.70 0.75 15.00 15.00 23.00 590 570 685- '16 1500:2300 620126001273512 16 16 350 XM11616 XTE1616 XMC1616 0.70 0.70 15.00 15.00 23.00 650 625 790 181:1 6,11211350: XMT18611 XTE1S612XMC186T 07512 o55:J3 oo: 15 5T 2100 590125651262512 18 8 350 XMT188 XTE188 XMC188 0.75 0.60 13.00 15.50 21.00 605 580 655 18 io:: 850-X Tj$f(l- X1E18102 xMc181o: 0 7512 0.68- 13 00: 15 50 21-00- 620' 5951 685-- 18'- 12 350 XMT1812 XTE1812 XMC1812 0.75 0.75 13.00 15.50 21.00 640 615 725 182: 1412 35012 xMTi814: xTE1814E xMc1814: 07512 0662 165011:1650: 2450 7551173012 87012 18 16 350 XMT1816 XTE1816 XMC1816 0.75 0.70 16.50 16.50 24.50 785 760 930 182181T35o1xMT1818:xTE18182xMc1818:0751 07521650:1650:2450 82012795129951: 20 6 350 XMT2O6 XTE2O6 - XMC2O6 0.80 0.55 14.00 17.00 22.00 725 695 760 2012 8212 3501 XMTZO8T XTE20611 XMC2O8I 0 8012 0.60-- 14 oo: --17.00- 2200 73512 70512 79012 20 10 350 XMT2010 XTE2010 XMC2010 0.80 0.68 14.00 17,00 22.00 755 725 820 2o11T113so:xM-r2o1z:xTE2o1z: xMc2o12:08012 075: 140021700 2200,7751745128601 20 14 350 XMT2014 XTE2014 XMC2014 0.80 0.66 14.00 17.00 22.00 795 765 905 2o:1216T135o1xMT2o16:xTE2o111xMc2o16:o8oTo7o121800:1800 2600 945191511085,: 20=1'118=1360 XMT2O18 XTE2O18 XMC2O18 0.80 0.75 18.00 18.00 26.00 985 950 1,155 tQ1:::.11 ZO111111T XMT2020 XTE2O2O' XMC2020' 080 _1 8:o 180 Z6Q -11'0 2Q-1090-11'.230-1 Weights in pounds, less accessories/Dimensions in inches 6 I SIGMA Corporation www.sigmaco.com <*> 4 t I * APPROVED M.mber I SIGMATM Quality - Service - Commitment - Delivered. H C C XTE XMC TEES AND CROSSES (continued) Size PSI TEE CROSS T TI A B S Tee XTE Cross Run Br MJxMJ MJxPE wt. wt. 24 4 350 XMT244 089 052 1500 19.00 885 24 6111 350: XMT246 XTE246 XMC246T 0 89T 0 55. 15 00 19 Q0_ 2300 985_ 945-1-025-1 24 8 350 XMT248 XTE248 XM0248 0.89 0.60 15.00 -1 g.'50 23.00 1,000 960 1ft045 24:_T,10 -- 50 xMT XTE241OT xMc241o: 0 89 .2410- 068: 15 00 19 00 23 00 1 020 0807"'11,085- 24 12 350 XMT2412 XTE2412 XMC2412 0.89 0.75 15.00 19.00 23.00 1,030 990 1,110 24:. I4 350 XMT2414.. XTE2414 xMc2414: 0 89 0 66: 15 OUT 19 00 2300 1 Q55 1015 1155: 24 16 -350'-X T2416 XTE2416 XMC2416 0.89 0.70 15.00 19.00 23.00 1,075 1,035 1,200 24 I8 350T xMT2418: XTE2418 xMc2418: 0 89 0 75: 22 oo: 220030 00 1 40Q-'j_,360... 1 590: 24 20 350 XMT2420 XTE2420 XMC2420 0,89 0.80 22.0022.00-30.00 1,450 1,410 1,675 24-24 -''a50' -X- MT2424.. X1E2424 xMc2424: 0 89 0 89 22 00 22 00' 30 00 1 535 1 490: 1 835: 30 6 250 XMT306 XTE306 XMC306 1.03 0.55 18.00 23.00 26.00 1 730 1.615 1,770 30 250: XMT3O8T: XT 308 XMC308Ti' 1 03T 060= 1800... 23 0O_ 2600 1 745 1 630W 1 795: 30 10 250 XMT3010 XTE3010 XMC3010 1.03 0.68 18.00 23.00 26.00 1,760 1,645 1,830 XM 301 30 .. - - - 1780 -1 666 -1,965 30 14 250 XMT3O14 XTE3O14 XMC3O14 1.03 0.66 18.00 23.00 26.00 1,800 1,685 1,905 30-16--'250 T xMT3o16:xTE3o16TT XMC3016 1 03 0'70 18.00 2300 2600 1 820 1 705 1 950: 30.. 18 250 XMT3018 XTE3018 XM03018 1.03 0.75 18.00 23.00 26.00 1,845 1,730 2000 30 20.... 250 XMT3020_ XTE3020_ XMC3620_ 1 03 0'80- '18.00 23.00_ 26 00 .1,875' 1 760 2 060_ 30 24 250 XMT3024 XTE3024 XMC3024 1.03 0.89 25.00 25.00 33.00 2,400 2,280 2,07 675 .3.0 ........... $0 ..... 250 .. XMT3030, XTE3030 XMC3030 1.03 1.03, 25.00 25.00,. 33.00, 2,595 2,480. 35 36 6 250 XMT366 115 055 2000 2600 2,223 36 250 XVT368 XTE368 XM0368 1115- 1.60 20 00 26 00 28'00' 2,520' 2 345 21565- 36 16--250 XMT3610 XTE361O XMC361O 1.15 0.68 20.00 26.00 28.00 2,535 2,360 2,600 36-':t2- -50 2 XMT3612 3-- XTE 115 075 2000 2600 2800 2550 2375 2630 36 14 250 XMT3614 XTE3614 XMC3614 1.15 0.66 20.00 26.00 28.00 2,570 2,395 2,665 36. 16.. 250 XMT3616_ XTE36t6 XMC3616... 1 15. 0 70_ 2000.... 26 00 2800 2 585 2 410_ 2 705_ 3618 250 XMT3618 XTE3618 XMC3618 1.15 0,75 20.00 .26.00 28.00 2,610 2,435 2,750 362 20T 2502 xMT362 0 : -1 TE3620 I xMc362o: f15T 0 80 20 oo: 26 oo. 28 00 2 635 2 460 2 805: 36 24 250 XMT3624 XTE3624 XM03624 1.15 0.89 20.00 26.00 28.00 2,690 2,515 2,910 36T. 30. 250_ XMT3630. XrE3630_ XMC3630 1s2 1 03: 28O0 28 OUT 3600 3 545 3 365 3965: 36 36 250 XMT3636 XTE3636 XMC3636 1.15 1.15 28.00 28.00 .36.00 3,745 3,565 4,370 422E 12. 2502 XMT4212 XTE42121 XMC4212... 1 282 0 75 2300 30.00-'-3l 00 3 555 3 335 3640: 42 250 XM14214 X1E4214 XMC4214 1.28 0.66 23.00 30.00 31.00_ 3,575_ 3 355 3,675 14 42:2 16: 250...: XMT4216 XTE42162: xMc4216T 1 282: 0.70'- 23.00- 30'00- 31.00 3,595 3 375 3,7.f5- 42 18 250 XMT4218 XTE4218 XMC4218 1.28 0.75 23.00 30.00 31.00 3,615 3,395 3,755 42T 02I 250 XMT4220 XTE42201.. XMC4220 1 2811 OM- 23'00-1 0 oo: $1-.00'-8,,040' 3,42(C 3010- 42 24 250 XMT4224 XTE4224 XM04224 1.28 0.89 23.00 30.00 31.00 3,690 3470 3,910 42. 30..J 250... XMT.4230 XTE4230 XMC423O 1 28.. 1 03_ 31 00 31 00 3900 4650 4425.. 5040.. 42 36 250 XMT4236 XTE4236 XM04236 1.78 1.58 31.00 31.00 39.00 61075 5,850 6,655 422:422:22502 XM14242. XTE4242 = XMC4242_ 1 7B..... 1'78-- 31.00- 31.00- 39.00' 6 320 5,005* 7.145: 48 12 250 XMT4812 X1E4812 XM04812 1.42 0.75 26.00 34.00 34.00 4,870 4,580 4.,955, 48 142 2502 XMT4B14 XTE48 142 XM04814... f422: U 661 26 001 34 O0 34 O0' 4 885 4 5954 985: .48 16 250 XMT4816 XTE4816 XMC4816 1.42 .0.70 26.00 34.00 34.00 4,905 4,615 5,0.5 48: 1822 250: MT..4818 XTE4818.. XMC481& i42 0 75.. 26 00 34 00 3400 4 925 4635: 5065 2 48 20 250 XMT4820 X1E4820 XMC4820 1.42 0.80 26.00 34.00 34M 4 950 4,660 5,115 -48--- 24_ 250.... XMT4824.... XTE4824....... XMC4824.... 0 89.. f,- 42...... 26 00.., 34 O0 34 00 4 995 4 705 5 210.... 48. 30 250 XMT4830 XTE4830 XMC4830 1.42 1.03 26.00 34.00 34.00 5,140 4,855 5,495 48:: 36:2 2502 XMT4836 XTE483 XNlC4B36 142 1 152 34 00-,34'.00- 42 00 6 280 5 995 6 790 48 42 250 XMT4842 XTE4842 XM04842 1.96 34.00 -M-.00 8,130 7,845 8,815 4'4L' o l'T4848 "TE448 "XM.c4848 T96 .834.00 3T400' 3400 O 20 8135 9,380' <*> 4 * I * APPROVED Member Weights in pounds, less accessories/Dimensions in inches SIGMA Corporation www.sigmaco.com 1 7 Size Item No. Wt. A Branch B I TI Run 6 6 XMH66 116 8.00 10.50 0.55 0.55 8 6" XMH86 XMH88 210 198 900 9.00 11-50 1150 06011 060 0552: 0.60 8 8 iO.._. 6..................XMHI06...... 27,0_ 11:00.... 13.50.. 0.68_ 0.55...._ 10 8 XMH108 11.00 13 50 0.68 0.60 1211: 6 XMH126L 341L 12 001: 14.50- 0.75"' 05521: 8 12 XMH128 300 12.00 14.50 0.75 0.60 '14',..- XMW46.. 500... i.400.._ 1650 0..66_ 0.55 ........ 14 8 XMH148 14.00 16.50 0 .66 0.60 16 6 XMHI66 540 15.00 17.50 0.70 0.55 16 8 XMH168 649 15.00 17.50 0.70 0.60 18............,.. XMFI186...... 50 3.00 17.50 0.75 0.55,__ 18 8 XMH188 13.00 17.50 0.75 0.60 20 Xt1H2061 829 1400 19.50 0.80' o155T 6 20 8 XMH208 14 00 19.50 0.80 0.60 24.............. 6............_ XMH246_ 1,134.... 21 50 0.89_ 0,55_ 24 8 XMH248 15.00 21.50 0.89 0.60 30' XMH306 '173 18.00 LQ 6 Ill T iI1.i.iiij ... ;"hR HYDRANT TEES MJ X FLANGE TEES Size I Item No. Wt. A B I TI 3 3 XMF33 5.50 5.50 0.48 0.48 42: 3 XMF43 ITT 6 5011: 6 5011 0 - 048T 4 4 XMF44 89 6.50 6.50 0'52--'0,5 2 6,,,.... 3....... 4 XMF63..,...,... XMF64 129 $Q0....... 8.00 8..00,_.... 8.00 Q.55_ 0.55 0,48..... 0.52 6 62 611 XMF662: 1401:1 8 0011 8-0 011 0 55 055: 8 4 XMF84 159 9.00 9.00 0.60 0.52 8 2:' 612 XMFB6T 1951: 9 00E 9 001:1 0 60,.._ _ 0"55_- 8 8 XMF88 175 9.00 9.00 0.60 0.60 io11: Cl XMF..1041: 229 11 00 ii 00 0.-687 0 52 10 6 XMF1O6 222 11.00 11.00 0.68 0.55 1011: 811 XMF1OB1: 250:1: T1001 11.00 0-0 060: 10 10 XMF1O1O 260 11.00 11.00 0.80-0.80 ,,12-4-- XMF124.: 3091: 1200.... 12'00 075: Q- 12 6 XMF126 336 12.00 12.00 0.75 0.55 121 821 XMF128T 330:1: 12 00_. 12 00 0751 0 601 12 10 XMF1210 380 12.00 12.00 0.87 0.80 12'T: 121 XMF12121400 ioo: 12:00: 0.871 0.87.1: 14 6 XMF146 490 14.00 14.00 0.66 0.55 14...... 8 XMF148, 0Q....,.... 14.O0_ 14.00...... 0.667 0.60..... 14 10 XMF1410 _____ 14.00 14.00 0.66 0.68 14 _ 12 .... XMF1.,1412_ 1400,.,.. 14.00. 0.66.... 0.75,.. _____ 14 14 XMF1414 14.00 14.00 0.66 0.66 16,... 4 XMF..1641:575.......... ,.15.0cL.. 15.00....Q-.7.0- 0.52..... 16 6 XMF166 605 15.00 15.00 070 0.55 161 822 XME168 615: 1$ 0011 1500: 070110602 16 10 XMF1610 635 15.00 15.00 0.70 0.68 161 121 xMEj612: 650_ 15 001 150010702: Q 75 16 14 XMF1614 15.00 15.00 0.70 0.66 161 6 XMFI6'16 1302: 1$10 16001' 07011 0O 18 6 XMF186 665 13.00 15.50 0.75 0.55 181 811 XMF1BBT 67511 13001 _1_5,50- 07511 060: 18 10 XMF181O 13.00 15.50 0.75 0.68 181: 12 xM0812: 7052: 130011 '15 5010751 01ST 18 14 XMF1814 16.50 16.50 0.75 0.66 18 - 16,_ XMF,.1816,,, ,.,,.,._ 16.50,..... 16.50_ 0.75.....,. 0. ,,_ 7O 18 18 XMF1818 915 16.50 16.50 0.75 0.75 201: 411 XMF2042 14001 17.00 0801: 0522 20 6 XMF206 820 14.00 17.00 0.80 0.55 201: XMF2O8I 8352: 14 00 17 o011 0'801 0 60: 811 20 10 XMF2010 14.00 17,00 0.80 0.68 -16--j-2- xAF2012: 86511 1-4-06- 17 00: OM- 0.715- 20 14 XMF2014 14.00 17.00 0.80 0.66 20-- J,6- XMEZO.1.6.. i,07..S.... ,18,00,_ 16,.Q0 ,... Q.80 ., 0.70 .,,.. 20 18 XMF2018 18.00 18.00 0.80 0.75 201: 2011 XMF2020 17165 18 0011 18 002 0801 o so: 24 6 XMF246 1125 15.00 19.00 0.89 0.55 24_ 8_ XMF248.,,... .1,140,, 15.00,.,., .19.00... 0.89...... 0. - 24 10 XMF241O 1.150 15.00 19.0b--.0:89 0.68 Weights in pounds, less accessories/Dimensions in inches 8 I SIGMA Corporation www.sigmaco.com Size Item No. Wt. A B T TI 24-12 - XME2412,. 1,165 15.O0_19,00....,0.89_ 0J5.,. 24 14 XMF2414 1,205 15.00 19.00 0.89 0.66 241:16: xMF2416lt23oj5O0,.... 19,00._.. 0.89_ 0.70..... 24 18 XMF2418 1,640 22.00 22.00 0.89 0.75 24=10- XMF2420: I 705,.. 22 0011 22 0011089,1: 0 Bo 24 24 XMF2424 1,795 22.00 22.00 0.89 0.89_ 30...... 6_ XME3O6., 1,7.10.....118.00...... 2300..... 1.03_ 0.55,.... 30 8 XMF368 1,725 18.00 23.00 1.03 0.60 30:: 101 XMF3010 '' 18001:23002 103T 06 30 12 X 301 18.00 23.00 1.03 0.75 301:14..,, XM F3014,. 118.00_ 23.00_ 1.0,3_ 0.66.,,.. 30 16 XMF3O16 18.00 23.00 1.03 0.70 30111 1811 XMF3018T j8 00112300111 1 0311 075 30 20 XMF3020 18.00 23.00 1.03 0.80 30 30 XMF3030 25.00 25.00 1.03 1.03_ 16--,6- XM36" 2'30: 20-00-- 260011 11511 0,55- 36 8 XMF368 2505 20.00 26.00 1.15 0.60 3611 10...,. XMF3610,,. 20.00,,,.. 26,00_ 1,15 .. 0,68..,,. 36 12 XMF3612 20.00 26.00 1.15 0.75 -36.-',t4- xrAF3614: ______ 20-00- 26 oo: r1511 0 6611 36 16 XMF3616 20.00 26.00 1.15 0.70 361181XMF3618,. _____ ____...20100......26M0,.. 0. 75,.,, 1. 15..,... 36 20 XMF3620 20.00 26.00 1.15 0.80_ 361: 2411 XMF3624 ______ W 2000Tl 260011 1'1511 0 89_ 36 30 XMF3630 28.00 28.00 1.15-1.03 3.61: 3611 XMF3636 ______ 28:00..... 28.00: 1.15..,. .11.15..... 42 12 XMF4212 23.00 30.00 1.28 0.75 42,.,,,. 14..... XMF4214.,. 23.00...,. 30.00,,,.. .1.28_ 0'66- 42 16 XMF4216 23.00 30.00 1.28 0.70 4211 1811 XMF42I8: 2:11.1: 23 0011 300011 1 2811 0 75: 42 20 XMF4220 23.00 30.00 1.28 0.80 4211 242 XMF 224: _____ - n'00- 30'00 1 2811 o8g: 42 30 XMF4230 31.00 31.00 1.28 1.03 4211 36: xME.4236: :1:11' 31 QO11 31 00 1 781 1 58: .42 42 XMF4242 31.00 31.00 1.78 1.78 48_ 8,,,.,,,,, XMF488, ______ 20.0Q_ 34.00...... ,1.42,,., 0:60_ 48 12 XMF4812 _____ 26.00 34.00 1.42 0.75 4811141 XMF4814,, 2600234 00' 1 42 0661:1: 48 16 XMF4816 26.00 34.00 1.42 0.70 48. 18,...,.. XMF48,'18... _____ 26,00_ 34.00_ 1.42,,.. 0.75- 48 20 XMF4820 26.00 34.00 1.42 0.80 48_ 24 XMF4824 26:00,,.... 34.00,,,.. 1.42,,.,. 0.89_ 48 30 F4830 26.00 34.00 1.42 1.03 48_ F,.4836,. _____ 34.00,,,, 34.00,,., 1.42...,,. 1,1 48 36,,.,,. lx~xlmml' 42 F4842 34.00 34.00 1.96 1.78 41: 4..E F4848 - 34,00" <~>4 t I * APPROVED Mmb.r C I I SIGMATIVI Quality - Service - Commitment - Delivered. T XMR (MJxMJ) A' ~A lj XSPR (MJxPE) XLPR (PExMJ) XPPR (PExPE) REDUCERS Size MJ Jj - MJ x PE - PF &ML 6400 - TI flj Item No Wt L Item No Wt L Item No jWt.. L Item No .fL. L 3 XMR43 40 7.00 XSPR43 35 15,00 XLPR43 40 1500 XPPR43 35 23.00 0.52 0.48 r64 3 1 XMR63T. 55T oC XSPR6S1.: 50.: 17 00 XLPR6ST 55E 17 00 XPPR63 50 25 00 0'55- 0'482 XMR64609.00 XSPR64 60 17.00 XLPR64 60 17.00 XPPR64 55 25.00 0.55 0.52 4TT XMR84.: O5 1100 XSPR84 802 9 00 XLPR842 0s2.: 80T9 oo: XPPR84.: 752 27002 0602 6 XMR86 95 11.00 XSPR86 90 19.00 XLPR86 90 19.00 XPPR86 85 27.00 0.60 055 loT(2xMR1o4: 1052 1200 xspRlo4%300: 2000 XLPR104 10022000 XPPR104 1oo.:28001o6.:o522 10 6 XMR1O6 115 12.00 XSPR'106 11520.00 XLPR106 115 20.00 XPPR1O6 115 28.00 0.68 0.55 IC 82 XMR1OB1 1352 1200 XSFR10'2 1302 2000 xLPR1o8: 1.302 20001 XPPR1O82 130 28 oo: 068.: o 60.: 12 4 XMR124 135 14.00 XSPR124 130 22.00 XLPR124 130 22.00 XPPR124 130 30.00 0.75 0.52 12: 6.... XMR126_ 1502 1400 XSPR126.: 15CC 2200 XLPR126 145.: 2200 XPPR126 145.: 3O0Q 0 762 o552 12 8 XMR128 165 14.00 XSPR128 165 22.00 XLPR128 165 22.00 XPPR128 165 30.00 0.75 0.60 121 101 XMR1210 1 190. 1400 XSPR1210 190222 00 XLPR21O 185.: 22 00' XPPR1210 185: 30.00- 0.75- 0 682 14 6 XMR146 190 16.00 XSPRI46 175 24.00 XLPR146 185 24.00 XPPR146 170 32.00 0.66 0.55 14 8 2 XMR82 14 2101: 16 00 XSPR14BT 1902 24 00 xLPRi48: 2052 4"Q 20 XPER 1482 1.9o2 3200 0 662 06a2 14 10 XMR1410 230 16.00 XSPR1410 215 24.00 XLPR1410 230 24.00 XPPR1410 215 32.00 0.66 0.68 14: 2: XMR1.412 2552 16 00 xsPR1T4i2: 2402 24 00 XLeR1..412 2552 24 oo XPPRi12 2402 32 OO 0 662 0 75 16 6 XMR166 230 18.00 XSPR166 210 26.00 XLPR166 230 26.00 XPPR166 210 34.00 0.70 0.55 162 82 XMR1B8.... 2502 WOO XSPR168T' 2302 26 00 xLPR1s8: 2502 26 00 XPPR1682 2302 3400 0'702 0602 1.6 10 XMR1610 280 18.00 XSPR1610 255 26.00 XLP.R1610 27.5 26.00 XPPR1610 255 34.00 0.70 0.68 162 12XMR1612 3052 1800 XSER1612:26522600 XLR1612 a05T2600XPPTh612 285 3400: 07020752 16. 14 XMRI614 335 18.00 XSPR1614 310 26.00 XLPR1614 315 26.00 XPPR1614 295 34.00 0.70 0.66 18 XMRI88.... 2952 -10-00 XSPR188T 270: 8 2 2700 XLPR188 -2952 27001 xPPR1a6.: M-35.0,67- 075.: 0 602 18 10 XMR1810 325 19.00 XSPR1810 300 27.00 XLPR1810 320 27.00 XPPR1810 295 35.00 0.75 0.68 18: 12:XMR1812 38 -T9-60 XSPR181232522700 XLPRI812 3o.:27oo:xpR1812 3Z523500 07520752 18 14 XMR1814 380 19.00 XSPR1814 355 27.00 XLPR1814 365 27.00 XPPR1814 340 35.00 0.75 0.66 IBTI6TXMR1$16 4152.1900 XsPR181639o22700 XLPR1816 39522700XER1816.3702350007520702 20 8 XSPR208 28.00 ... 0.80 0.60 20 10. XMR2010 3752.2000 xseR2olo: 34522800 XLPR2O1O 3752 2800 XePR2010 345 3600 Q.80--,O-.Q82 20 12 MR X2612 405 20.00 XSPR2012 375 28.00 XLPR2012 405 28.00 XPPR2012 375 36.00 0.80 0.75 202 14 XMR2014 4302 20'00' XSPR2014 4001: 28M- XLPR2014 4152 28 001 xpp201.4: 38$2 a"- 0802 q- 20 16 XMR2016 470 20.00 XSPR2016 435 28.00 XLPR2016 445 28.00 XPPR2016 415 36.00 0.80 0.70 20: 18 XMR2018 51CC 2000 XSER2018.. 4752 2800 XLPR2O18 4852 2800XPPR2018 4552 3600 08020752 24 8 XMR248 457 24.00 . 0.89 0.60 24 122 XMR2412 5502 24 00 xsPR2412: slo2 32O0 XLP2412 5502 32-00- XPR2412 5102 40 oo: o891 0751: 24 14 XMR2414 575 24.00 XSPR2414 535 32.00 XLPR2414 560 32.00 XPPR2414 520 40.00 0.89 0.66 24--'16- XMR2416 61522400 xsP2416: 57523200 XLPR2416 595232 oo: XER2416 5552 40001 08920702 24 18 XMR2418 660 24.00 XSPR2418 620 32.00 XLPR2418 635 32.00 XPPR2418 595 40.00 0.89 0.75 24 20: XMR2420 7052 24.00 XSPR2420. 6651. 32.00'* XL _P2420' 6752 32 0O XpjZ420 6a$--,40-00 . Q-8 - 0,80- - 30 6 XMR3O6 30.00 1.03 0.55 3028 .. 22 .:.7XSPR3082 6292 3800 103T 0507 ______ _______ .:::- 30 12 XMR3O12 30.00 1.03 0.75 30_ 16 XMR3O16 9852 30 00 XSRR3O16T 9002. 38 00 LPR3016 9102 38O0. xPPR3o6T 22 46 00 1 032 0702 30 18 XMR3018 990 30.00 XSPR3018 885 38.00 XLPR3018 965 38.00 XPPR3018 860 46.00 1.03 0.75 302 20 XMR3O2O 1 050 30 00 xspR3o2o2 9451: 38 00 XLPR3O2O 1-020- 38.'00- XPPR3O2O 9152 46 00 1.M- 0 802 30 24 .XMR3024 1j.5 30.00 XSPR3024 1,060 38.00 XLPR3024 1,125 38.00 XPPR3024 1,020 46.00 1.03 0.89 36 1& XMR361 36.00 -.- 1.15_ O.66 . . 36 18 XMR3618 36.00 1.15 0.75 36 20: XMR3620 f450 36 00 XSPR3620 f285 44 00 XLPR3620 142o: 44 001 XPPR362OT 1255 52 00 1 15 0 802 36 24 XMR3624 1580 36.00 XSPR3624 1,410 44.00 XLPR3624 1,535 44.00 XPPR3624 1,370 52.00 1.15 0.89 361: $0: XMR3630 *1,855 36.00' XSeR3630... 1 69Q 44 00 XLPR3630 1 750144 00 XPPR363O 1 585 52 00 115: 1 032 42 20 XMR4220 1,915 42.00 XS 4220 1,705 50.00 XLPR4220 tMO 50.00 XPPR4220 1,670 58.00 1.28 0.80 422 24. XMR4224 2 060 42 00 XSPR4224 1 855 5000 )LPR4224 2 O20 50 00 xPR4224 t10 58 00 1 282 0 892 42 30 XMR4230 2,370 42.00 XSPR4230 2,165 50 00 XLPR4230 2,265 50.00 XPPR4230 2,055 58.00 1.28 1.03 42 36: XMR4236 2,695 42 00 XSPR4236 2 485 M-0 XLER4236 2 5301 $0 0o XPER4236T 2 320 58 Oo 1 282 1152 .48 24 XMR4824 45.00 XSPR4824 56.00 . 482 30 MR4830 3 005 48 00 xspR483o: 2 740 56 00 LPR4830 2 9QQ 56 Oft.. XPP..R48301 2 635 6.4 oo: f422 1 032 48 36 XMR4836 3,370 48.00 XSPR4836 3 100 56.00 XLPR4836 3,205 5600 XPPR4836 ........ ..... 2940 6400 1 42 ...89 115 48 42 XMR4842 3.7 0' XSPR4842 56Q0' )LPR4842' 3,540 56.00' XPPR4842 64.00 142 118 <S>A Weights in pounds, less accessories/Dimensions in inches' APPROVED SIGMA Corporation www.sigmaco.com 1 9 XM FA 0 ®M 'e 'i !WI Eel J...I 17.1 I Size Item No. Wt. L 3 4 6 XMFA3 XMFA4.____ XMFA6 XMFA1O XMFA12ET XMFA14 XMFA1 61:: XMFA18 XMFA2OE1: XMFA24 XM.EA30_._ XMFA36 XMFA48 42121 XMFA42ET 30 ________ 40 -_______ 60 115 11155_ ________ ___11 195 240 280 340 455 760 8.00 8.00__ 8.00 8.00 :00 0.48 0.52 0.55 00_______ 068 0.75'_______ 0.66 o:7o 0.75 0.80..,,,... 0.89 103_______ 10 1.2_................T 14 116_ 8.00 800. 8.00 18 20______ 8.00 10.00 10.00 1200 12.00 24 30 36 1070 1505 1885 1.15 j 28 1.42 48 MJ X FLANGE 900 BEND SIZE Item No. A S T 14 XMFB1490 XMF81690 14.00 15,00 14.00 15.00 0.66 0.70 ,f6--- 18 XMFBI890 16.50 16.50 0.75 20 XMEB2O,9021 18.00 - 1,8.Q0. ox-_ 24 XMFB2490 22.00 22.00 0.89 36 ' XMFB3690 28100 115 28:oo MJ X FLANGE 450 BEND SIZE I Item No. A 30 XMFB3O45 XMEB364521 XMFB4245 XMFB4845 15.00 18100 21.00 _____ 24:00- 15.00 - 21.00 1.03 36 _________ 42 48 1.28 24:00 r42 MJ X FLANGE REDUCER S XMFR Size I Item No. L I TI Wt. 4 3 XMFR43 7.00 0.52 0.48 6-3--)( MEF63E 9100111 0.5$11 048 6 4 XMFR64 9.00 0.55 0.52 8111 411 XMFR84:E 11 0011 0 6011 0 8 10111 6 411: XMFR86 XMFR1O4 11.00 12 002 0.60 0 6811 0.55 o 52: 0.55 10 6 XMFR106 12.00 0.68 10118XMFR108 120011 068T'060T,,,.. 12 4 XMFR124 14.00 0.75 0.52 1211 621 XMFR126III 14.00: 0:7521 o.55 12 8 XMFR128 14.00 0.75 0.60 121: 110: xMF.R'12 101 .00: 0:75:1:1 681 14 1411 6 8111 XMFR146 XMFR148T 16.00 16 001: 0.66 0 6611 060: 0.55 0.68 14 14_ 10 12 XMFR141O XMFR14,12 ,,16,00 16.00 0.66 O 6='O.715.,. 055_ 16 6 XMFR166 18.00 0.70 :16:1: 8.1 xMFR168T 118.Q0.. o:o__ 0.60,,, 16 1611 10 122 XMFRI6IO XMFR1612 18.00 18 00111 0.70_ 0 70..... 0.68 (Q-5 1:1111 16 14 XMFR1614 18.00 0.70 0.66 1811 611 XMF186T -18 -0- 0,."7-5,,-- 0.65 18 j8, 8 10,,,. XMFR188 XMFR181O, 19.00 19.QQ_ 1 19.00 0.75 0.75_ 0.60 0.8_ 0.75 1 18 12 XMF812 R1 0.75 Weights in pounds, less accessories/Dimensions in inches 101 SIGMA Corporation www.sigmaco.com Size I Item No. L I TT wt. 18 14 XMFR18I4 19.00 0.75 0.66 is:: 16: xMER18i6::19:oo: 017511 070 20 10 XMFR2010 20.00 0.80 0.68 O'-,-t2 KM R202 20001:018011 07$1 20 20_ 14 16.. XMFR2014 XMER20I6. 20.00 20.00 0.80 0,80_ 0.66 0,70.... 20 18 XMFR2018 20.00 0.80 0.75 24 112 XMFR242' 24.00,, 08$11 017.51 - 24 14 XMFR2414 24.00 0.89 0,66 2411 1162 XMF24i6 24.00: 24 18 XMFR2418 24.00 0.89 0.75 24,,,.. 20_ XMER242O, 24.00,,,,,, 0.89,._ 0.80,,,,,, 0.80 0.75 30 3011 18 201: XMFR3018 XMFR3O2O1 30.00 30.00: 1.03 1110311 30 3611 24 20: XMFR3024 XMFR3620' 30.00 36001: 1,03 1:15210.180: 0.89 36 3611 24 302 XMFR3624 XMFR3630 36.00 36:00: 1.15 11 -j -Q$- 0.89 0.80 42 42 20 24 XMFR4220 XMFR4224 42.00 42.00-- 1.28 "f26-- 0,-- 8 42 30 XMFR4230 42.00 1.28 1.03 42:1 36: XMFR4236 42:00: 11128111:15: 48 4811 30 36: 48 XMFR4836 48.00 48 0011 4.2 1.42 14211 1.03. 115 - 11.28. 1 48 XMFR4842 48.00 1.42 <*> 4 (R I ( , @ APPROVED M.mb.r -:- SHORT SLEEVES LONG SLEEVES . Item No. L Wt. Item No. L 3 XMS3 7.5 25 XML3 12.0 .48 XMS411 75111 30 41111 351111 5211 4511 6 XML4T11 12 0 45 611 65 8112 851111 10 XMS6 XMS811 7.5 7511 r.48 XML6 XML8I:11 12.0.55 20 6011 XMS1O 7.5 85 . XMLIO 12.0 .68 115 1211 XMS1211 75 11011 XML1Z11 12 0.......: 75:11 1S:121 14 XMS14 9.5-.66- 150 XML14 15.0 .66 195 1622 XMS1611 9511 7011 180111 XML16T11 15 011 701212 23521 18 XMS18 9.5 .75 215 XML18 15.0 .75 285 2022 XMS20119 5118011 240 XML2OIT 15011 8O11 32511 24 XMS24 9.5. .89 320 XML24 15.0 .89 425 3011,. XM$3011 15 011 1 0312 635 11 XML3O 241011 J-03- 88522 36 XMS36 15.0 1.15 855 XML36 24.0 1.15 1190 4212 XMS42211 iS 011 1 2812 11152 XML42TI 24011 f2811 1 '55012 48 XMS48 15.0 1.42 1.385 XML48 24.0 1.42 1,940 -I- I SIGMATIVI Quality - Service - Commitment - Delivered. S ECCENTRIC REDUCER Size I Item No. L i Ijj wt. .4 3_ XMRE43. 7.00 6 62 3 411 XMRE63 XMRE64TL 900 9 0011 1 055 0 5511 0 52 2 0.48 8 8T11 4 611 XMRE84 XMRE86TT 11.00 ff0O. 060 0'60- 05" 0.52 052 Q5L.____ 10 4 iO_XMR1Q6..... XMRE104 1200 2 0 068 0,68_ 0.60 10 8 r XMRE1OS XMRE124 12.00 14.00' 0.68 0.75 0:52 0.55 12 12_ 6 8--... XMRE126 X.M.RE12EL_ 14.00 t400.... 0.75 12 1411 10 611 XMRE1210 XMRE146E: 14.00 16.00- 0.75 0-.66.-- 0.68 0 55 14 1411 8 101 XMRE148 XMRE141OI' 16.00 16 oo: 0.66 066E 0.60 0 68: ______ 14 1611 12 62 XMRE1412 XMRE166.11 16.00 160012 0.66 -0'70'- .0.7.5 05: 16 '16-'16- 8 XMREI68 XMRE161 0T 18.00 18.'00- 0.70 0.70- 0.60 0'.087 16 1611 12 14 XMRE1612 XMRE1614T 18.00 18'00-1 0.70 0.70- 0.75 18 1811 8 10 XMRE188 XMREIB1OT 19.00 1900207511 0.75 0.60 0681 18 1811 12 14 XMRE1812 XMRE181411 19.00 190012 0.75 0.75 7511 0 6612 _____ 18 2011 16 lot XMRE1816 XMRg2010T 19.00 20 oo2 0.75 08011 0.70 0 68: 20 20_ 12 14: XMRE2O12 XMRE2O14T 20.00 20 o0 0.80 0 8011 0 0.75 20 16 1 M XMRE2016 20i8 20.00 20.00 0.80 080 0.70 i1v4I1 Size I Item No L T, I T1 Wt. 24 6.. XMRE246.... 24...0.0_ 0,89_ 0..55._ 24 12 XMRE2412 24.00 0.89 0.75 24,, XMRE2414.... 24.00.... 0.89_ 0.66,.. 1 070 24 2411 16 181.. XMRE2416 XMRE2418I 2400 24-00- 089 089110 7512 0.80 24 20 XMRE2420 . 24.00 0.89 30_ 16...,. XMRE3OI6,..,,,. 30 18 XMRE3018 30.00 1.03 0.75 ..30.....ZQ..... X..MR020... 30.00 .1.03,......0,80,.... 0.89 30 24 XMRE3024 30.00 1.03 3611 141 XMRE36I..411 36 002 115110 661 36 20 XMRE3620 36.00 1.15 0.80 6T 24 XMRE3S24TI 36.0011-15--0- 36 30 XMRE3630 36.00 1.15 1.03 4211 2O xMRE422pT 42 00 1 2811 0 8012 42 4211 24 30 XMRE4224 XMRE4230 42.00 42 002 1.28 1 2811 0.89 1 03: 42 48 36 24 XMRE4236 XMRE4824 42,00 4500 1.28 14~ .0 1.15 48 4811 30 361 XMRE4830 XMRE483612 48 00 480012 -1.42 f4211 1.03 115 48 42 XMRE4842 48.00 1.42 1.28 1 SLEEVES XMS XML S A t I ! APPROVED fhmbw Weights in pounds, less accessories/Dimensions in inches SIGMA Corporation www.sigmaco.com Ill MJ x MJ em i O . VVL , j , , ' MJ x PE Item No Size 3x5 XM035 5 W 0.48 XMQ35 12 30 0.48_ 3x6 TT XMO36E 5:E 0 6 J,0-0:48- 3x12 XM0312 60 12 22 0.48 XMQ312 18 38 0.48 3x18....,..... XM0318_ 5_ j8,. 30....... O.48_ XM0318 6.._.., 27_.... 0.52_ _____ _____ 4x6 XM046 75 6 19 0.52 XMQ46 0.52 12 30 012TT XM0412 85: 12T 22T 0:52 XM0412 18: $8T 0 52 4x18 XM0418 105 18 30 0.52 XM0418 24 44 0.52 6x6....._..... XM066_ 110_ 6_ 20...... 05 XMQ66..,. 12.00,.. 34.00.,. Q,55...... _____ 6x12 XM0612 135 12 26 0.55 XMQ612 130 18.00 41,00 0.55 6i%--XMO618 165 10: 33: 0-55- xMQ618: 16Q 24 00 47 00 0-55* 6x24 XM0624 195 24 39 0.55 XMQ624 195 6 29.00 0.60 86Ei1 XMO86TT 1601E 6TT. 2cT 060T XMQ86T _____ i2 36 oo: 0 60 18 8x12 XM0812 200 12 28 0.60 XMQ812 43.00 0.60 8118 XM018 245 18 35' Q-60- XMQ818: 24 45'00- 0 60 8x24 XM0824 325 24 41 0.60 XMQ824 6 30.00 0.68 10x6j XM0106 220 6TT 22 1T 0-.68- XMQ1O6 1 _____21T 38--.00- 0"1-'-- 10x12 XMO1O12 250 12 30 0.68 XMQ1012 18 46.00 0.68 10x18 XMO1018 340= 18 3T 068 XM,.1018 10x24 XM01024 400 24 44 0.68 XMQ1024 6 34.00 0.75 12x6.... XM0126 320,. 6_ 26.......... 075.., XMQ126... _____ 12,....,.... 45.00_ 12x12 XM01212 420 12 37 0.75 " I7 XMQ1212 18 56.00 0k75- 2x18TxMo1218:s2ow.48TTo75TxMoi2i8 .24T620007T 12x24_ XM01224 600 24 54 0.75 XMQ1224 6 35.00 0.66 14,.x,6_ XM0146 380,. 6........ 2L_..,. 0.66..,, XMQ146..,, _____ _____ ,.12..... 46.00.. 0,66....... 14x12 14i:18: XM01412 xMo1418: 480 ss: 12 8: 38 -4:9= 0.66 0 66....i XMQ1412 XMQ1418 18 24= 57.00 03'00- 0.66 0'66_- 14x24 XM01424 24 55 0.66 70 XM01424 6 35.00 0.70 16xIi- XM01612 600 16ii8:xMo1618:71o1isT,,5oEo7oTxMo1618 12 40 0.70 XMQ1612 18 246400:o7o 58.00 0.70 16x24 18i61i XM01624 xM0186 XM01812 : _____ 24 56 0.70 75 XMQ1624 xMQ1s6: 36.00 48 00 0.75 o 7S,....... 6 12T: 18x12 18.x.18 18 x 24 .... XM01818_ 12 40 0.75 ... XMQ1812 18 59.00 0.75 1& ______ 24 ... 20.x,6 XM01824 XM0206 57 28_,...,.. 0.75 0.80 XMQ1824 XMQ205. _____ 6 12,.,........ 36.00 48.00,.. 0.80 Q-80- 6,,,,...,. 2002 20x181. X 0201 XMO2o18: 725 1-05 01 12 18T.... 40 52 0.80 0 BOT. XMQ2012 XMQ2O18 _____ _____ 18 24: 60.00 66 0o 0.80 0 80 20x24 24,j($= XM02024 XM0246... 1,45 24 580.80 28 0,89 XM02024 XMQ246 _____ 6 12 36.00 48 00 0.89 089:: 6 'it.._ 24x12 24..xi8.... XM02412 XM02418... ______ 12 40 0.89 0.89_ XM02412 XM..Q24i8 _____ _____ 18 2,4.... 60.00 66.00... 0.89 Q.89_ ______ 18_ 52_ 24 x 24 XM02424 L. 0.89 XM02424 XMQ OFFSETS S SLEEVES Size LONG SLEEVES Item No. L Wt. 4 XMML4 XMM0_____ XMML8 )(iML10TE XMML12 XMMLI6TE XMML20 XMML24 12 46 6 8 10 12 16____ :12 63 12 12 8-4 If 149 12 15 235 20 24' 15 '1 362 484 Weights in pounds, less accessories/Dimensions in inches 12 SIGMA Corporation www.sigmaco.com <*> 4 APPROVED Mamb.r I SIGMATIVI LATERAL WYES SiZe Item No. Wt. A B C T TI 3 3 XMY33 60 10.00 3.00 10.00 0.48 0.48 4_ 3 XMY43 85,......... 1200.... 300_ 1200052_ 0481 4 4 XMY44 95 12.00 3.00 12.00 0.52 0.52 6Ti3... XMY63:. 125T 14502 301145Q...055.. 0481 6 4 XMY64 135 14.50 3.50 14.50 0.55 0.52 6___ 6_ XMY66 ....,. 150_ 1450.... 350..... 1450_ 0557 055.... 8 4 XMY84 190 17.50 4,50 17.50 0.60 0.52 8....6.........XMY86... 205-17.50,... 4.50 17.50.. 0,60..... 0.55. 8 8 XMY88 225 17.50 450 17.50 0.60 0.60 IO 42 XMY1 042 flOE 205,O_ 5.00 - 20 50 0 68 0'52 10 6 XMY106 285 20.50 5.00 20.50 0.68 0.55 10 07-7 XMY108 305E 205o: 5:00- 26.5Q7 0682 0601 10 10 XMY1010 375 20.50 5.00 20.50 0.68 0.68 12T14..T..XMY124I 380T245550i2457 075T 0522 12 6 XMY126 390 24.50 5.50 24.50 0.75 0.55 12_ 8....... XMYI2B_ .5 41..._ 24.50 .... 5.56 24.50.... 0,76.. o-60- 12 10 XMY210 500 24.50 5.50 24.50 0.75 0.68 122 12XMY1212 535=24502550' 24-50-:0752 Q75 14 4 XMY144 540 27.00 6.00 27.00 0.66 0.52'-- 14-- 6E XMY146' 565E 2700 600 27 oo: 066: o551 14 8 XMY148 595 27.00 6.00 27.00 0.66 0.60 14"10XMY1410 63oE2700:600,....2700:066:068 14 12 XMY1412 690 27.00 6.00 27.00 0.66 075 14... 14_XMY1414 700..... 2700...,. 600..... 27 00.... 066...,. 06- 16 4 XMY164 720 30.00 6.50 30.001-01,70-0.52 162 6.2 WY-166- 755 ..2 3OOO 6-507- 30 oo: 0.70 - 0-.5-5-- 16 8 XMY168 790 30.00 6.50 30.00 0.70 0.60 162 lOT XMY1610 85oE'a000:6 50 3000_ 070: 068 16 12 XMY1612 905 30.00 6.50 30.00 0.70 0.75 162 14: XMY1614 865E -3,0700-6 50 o oo: 070: 066: 16 16 XMY1616 890 30.00 6.50 30.00 0.70 0.70 i 10... 4....... XMY184,... 92_ 25.'00- .1.00-- 27 50,... 0'76-- 0.52 18 6 XMY186 960 25.00 1.00 27.50 0.75 0.55 188XMY1B8 18 10 XMY1810 1,070 32.00 7.00 32.00 0.75 0.68 .1$212: XM11812 1130: 32..002 7.00 - 32 00. 075:0752 18 14 XMY1814 1,115 32.00 7.00 32.00 0.75 0.66 187 16,.. XM'?1816 .1 150.. -8:2'.-0o L0 32 oo: 0 752 016 18 18' XMY1818 1,190 32.00 7.00 32.00 0.75 0.75 20_ 4......... XMY2O4,,,. 1'250-- 27 00_ -0.00,- Z9--.50- 0A 0-.5Z- 20 6 XMY206 1,300 27.00 0.00 29.50 0.80 0.55 20.2 8.22 XMY2O8T,. 1 365: 07 27 oo: 0'007 2 $0" o8o 0'60- 20 10 XMY2O1O 1435 27.00 1.00 29.50 0.80 0.68 202 122 XMY2012 5402 35,Q 8.00 35.'00-'0.8o-- 0-.75 20 14 XMY2014 565 35.00 8.00 35.00 0.80 0.66 202161 XMY2,016 595.235 oo: 80013500:0802070: 20 18 XMY2018 630 35.00 8.00 35.00 0.80 0.75 20 20.,.. XMY2020 690,...... -3-5'00,--- 8 00_ 35 00_, 0 80,..,. 0 80_ 24 .. 6 XMY246 953 31.50 0.50 31.50 0.89 0.55 24 ' 8 XMY248 1,625 31.50 0.00 34.50 0.89 0.60 24 10 XMY241O 1660 31.50 0.50 34.50 0.89 0.68 241 1 - XMY2412': 11002 31 50 0 50' 34.'56 0 8912 0 7512 24 14 .XMY2414 1j60 40.50 9.00 40.50 0.89 0.66 242 16XMY2416 115,.4050 900405o:o69:070 24 18 XMY2418 1,880 40.50 9.00 40.50 0.89 0.75 2412 20: XMY2420 "1 950 '40.'50-- 9 002 401$0' 0 892 0.80_1 24 24 XMY2424 2,115 40.50 9.00 40.50 0.89 0.69 302 8.2 XMY308 ...112 49.00-,, 10,00. 100-J.03- 30 12 XMY3012 2,850 49.00 10.00 49.00 1.03 0.75, 302 14 XMY3014 2 915 49 oo: 10 W 4900: 1 032 0662 30 16 XMY3016 2,975 49.00 10.00 49.00 1.03 0.,70 302 i&: XMY3O18 3 040: 49 00 10'00' 49 o.o: f03.2 0 752 30 XMY3020 3,115 49.00 10.00 49.00 1.03 0.80 302 120 24--XMY3024 I XMY3030 3,280: 49'oo: 10 00,. 49 00 1:63- 0,'$9: 3_. 3. 3.670 52.50 i. 52.50 LQ... LQ.. <*> 4 t I (@ APPROVED M.mbi, Quality - Service - Commitment - Delivered. MY Size 1 10 Wt. A B C T TI Run Br 362 121 XMY3612 4 895 54 O0_. 1525 5400.... 1 15_ 0 75.... 36 14 XMY3614 4,970 5400 1525 5400 115 066 362 30:' XMY3630 58051 5600T 1525 56 oo:1"15: 1 03: 36 36 XMY3636 60.00 19.50 60.00 1.15 1.15 422 122 XMY4212 _____ 62-60- 000: 52'06-'f-18- 42 20 XMY4220 _____ 60.00 12.00 60.00 1.28 0.80 2E 24: XMY4224 60 oo 12 00 60 00 1 28: 0 89: ,. _..._.. 42 30 XMY4230 63.00 12.00 63.00 1.28 1.03 42.2 36: XM'4236 001 12 QO 66.00-- 42 42 XMY4242 71.00 15.00 71.00 1.28 1.28 48" 6.2 XMY486 22 62.00- 0.00- 66 00 r42T o"s5: 48 8 XMY488 52.00 0.00 60.00 1.42 0.60 48...... 12,... XMY,4812 52,,00_ 0-00-,60(L .1,42,.. 0.75 . 48 16 XMY4816 52.00 0.00 66 00 1.42 0.70 48,,,,, 20_ XMY820 1 52.00 0 .. 00 66"00-- 1 42,... 6:8Q- 48 24 XMY4824 58.00 5.00 64.00 1.42 0.89 48.2 301 XMY4830 _____ 0 59 0 4 00. 6400: 1 42: 1 03 48 36 XMY4836 64.00 5.00 68.00 1.42 1.15 482 42: XMY4842 77 00_ 1200 7700 17-42- 48 48 IXMY48481 .77.00 16.00 77.00 1.42 1.42 42" and 48" lateral wyes are available on special order. Contact SIGMA for details. Weights in pounds, less accessories/Dimensions in inches SIGMA Corporation www.sigmaco.com 113 Size PLUGS ________ Solid T TI Wt. 3 XMMP3 4MMP.4....7 XMMP6 XMMP8 XMMP16 X4P1' XMMP14 XMMPI6 XMMP18 XMP20 XMMP24 0.50 0.60 0.65 01710 0.75 0175 0.32 0 0:59 .96 1:03 1.16 0,48 0.52,. 0.55 10 )6 26 47 4-- 6 10 0.68 0T75 65 88 12 ______ 14 0.66 :i.s_____ 16 18 20 24 0.75 0.80 0.89 185 225 335 TI T1 CAPS (XMK) CAPS (XTK) PLUGS (XMP) PLUGS (XTP) CAPS AND PLUGS ____ CAPL.. - - ____ _____PWQS____ Size Solid Tapped T TI Wt. Solid Tapped T TI I Wt. 2 XM132 0.48 3_ XMK3... XTK37.. 0.50.. 07481121- XMP3.... XTP3_... 0... .50.48 0 .. 4 XMK4 XTK4 0.60 0.52 15 XMP4 XTP4 0.60 0.52 15 6: xMK6: XTK6 0(W 0'."55-- 25 XME6: XTP6 06520 %::,2 8 XMKS XTK8 0.70 0.60 45 XMPB XTP8 0.70 0.60 45 1XMK10 xTK1o:076 068 eo: XMP10 xT1o:o7s o68 T:65: 12 XMK12 XTK12 0.75 0.75 80 XMP12 XTP12 0.75 0.75 90 I4T1 XMKI4 XTK14T 032 066 110 XMPj4 )(1-E.14: 0 32 0 65 115 16 X 1 XTK16 0.89 0.70 150 XMP16 XTP16 0.59 0.70 145 I8JXMK18 XTK18 096 075W 1851XMF?18 X1P18096..075:180TT 20 XMK2O XTK2O 1.03 0.80 200 XMP20 XTP20 1.03 0.80 200 Z4= XMK24 XT K24: 1 16 0 89 300 XMP24 x-rP24: 1i6 0 89 390 30 XMK30 XTK30 1.03 590 XMP30 XTP30 1.03 573 36L XMK36 XTK6 ____ f15 850 XMP36 XP36 1-15: 815 42 XMK42 XTK42 1.28 1180 XMP42 XTP42 1.28 --1'1-42- 1,110 48 XMK48 XT08 112 1.595 XMP48 xT048 1.465- 0 Weights in pounds, less accessories/Dimensions in inches 141 SIGMA Corporation www.sigmaco.com <*> 4 (R * APPROVED Mber I SIGMA. Quality - Service - Commitment Delivered CIIO Flanged Fittings Non-Standard Items: Item # I Description XMBIO6 C110 DI 10' X 6" MJ X MJ REDUCING BEND XMB2II CI10 DI 2" MJ x MJ 11-1/4 DEGREE BEND XMB222 C110 DI 2" MJ x MJ 22-1/2 DEGREE BEND XMB245 C110 DI 2" MJ x MJ 45 DEGREE BEND XMB290 C110 DI 2" MJ x MJ 90 DEGREE BEND XMB4205 C110 DI 42" X 42" MJ X MJ 5-5/8 DEGREE BEND XMB4805 C110 DI 48" X 48" MJ X MJ 5-5/8 DEGREE BEND XMB84 C110 DI 8' X 4" MJ X MJ REDUCING BEND XMCI64 C110 DI 16" X 4" MJ X MJ CROSS XMC22 C110 DI 2" X 2" MJ X MJ CROSS XMC32 C110 DI 3" X 2' MJ X MJ CROSS XMC83 C1 10 DI 8" X 3" MJ X MJ CROSS XMH366 C110 DI 36" X 6" MJ X SWL TEE XMS2 C110 DI 2" X 2" MJ X MJ SHORT SLEEVE XMTIO3 C110 DI 10" X 3" MJ X MJ TEE XMTI23 C1 10 Dl 12" X 3" MJ X MJ TEE XMT32 C110 Dl 3" X 2" MJ X MJ TEE XM1343 C110 DI 3" X 4" X 3" MJ X MJ X MJ TEE XMT42 C110 DI 4" X 2" MJ X MJ TEE XM1426 C110 DI 42" X 6" MJ X MJ TEE XM1446 C110 DI 4" X 4" X 6' MJ X MJ X MJ TEE MC: W/ 6" SI XMT83 C110 DI 8" X 3" MJ X MJ TEE XMY83 C110 DI 8" X 3" MJ X MJ WYE Note: Contact SIGMA for more information on non-standard fittings C C <*>4' APPROVED Membw Weights in pounds, less accessories/Dimensions in inches SIGMA Corporation www.segmaco.com rib LOCATt3NS .... I \ • 2-48" mechanical joint fittings (AWWA C153 & C110) North Regon •2-48" C1 10 / 54-64" C153 flanged fittings (cast iron also available) - , 3-48" MJ and 3-48' Flanged AWWA Fittings, Domestic Manufacture Cream Rtog. New Jersey (HQ) ./ •4-24" TRIM TYTOW C153 /14-24" TYTON® push on fittings 4-24" C 11 push on fittings Phone (900) 9,5,C • C116 fusion bonded epoxy lining available Fax 116)9) 758-1158 PROTECTO 401® ceramic epoxy lining available crm saIes gmaco corr Sauk Vi .age Ililiols Prepackaged and loose mechanical joint accessories Phone (BI3R) 999-00 SIGMASEAL' improved mechanical joint gasket Snap-On multi-purpose gasket for ductile iron or PVC pressure pipes Fax 1708) 758-6790 • Ductile iron set screw retainer glands cti-SE.Ies@sigm3co.com • OMNl-SLEEVE" improved wall penetration sleeve Specialty bolts and nuts for mechanical joint assemblies L.o. 1ill1 Sout' Re.br • 3-48" ONE-LOK SLDE restraint for ductile iron pipe (import or domestic) okk • 3-36" ONE-LOK SLCE restraint for PVC pipe (import or domestic) axarder Cily, Alabama • 3-36" ONE-LOK SLDEH bell joint harness for ductile iron pipe Phone (30:) 324-451 '4-12" / 20" ONE-LOK SLDM restraint for oversized cast iron pipe Fax (256) 234-456 • 4-36" ONE-LOK SSLD split restraint for existing ductile iron pipe rDs--aatet-)@s~gmaco.com c - .' • 4-36" ONE-LOK SSLDI-I split restraint harness for existing ductile iron pipe - 4-12" ONE-LOK SLCEH bell joint harness for PVC pip Houston, Texas . __ __'L___1 Phore (800)999-0109 '4-48" PV-LOK PWM Restraint for MJ Fitting to PVC pipe - Fax (281) 987-0200 '4-48" PV-LOK PWP Restraint for PVC bell joint restraint 4-48" PV-LOK PWPF Restraint for PVC fitting to PVC pipe h -i-satess.gmaccicorn •4-12" PV-LOK PWH PVC bell joint harness 2-12" PV-LOK PVM Restraint for MJ Fitting to IPS PVC pipe 'West Rec.cn & Canada .2-12" PV-LOK PVP Restraint for IPS PVC pipe bell joint 4-8' PV-LOK PVPF Restraints for PS PVC pressure fitting OntariD, California Phore (800). 688-6230 .. I Fx (90) 39 -2033 ztrt-sales@stmaco.com • 3-36' SIGMAFLANGE SFA flange adapter sleeve for PVC and DIP 2-48' ZIP FLANGE set screw style flange adapter Auburn, Washington Fhore (600) 686- 6230 F9x(909)391-2033 I ont-salsQsigmaco.com Manhole Rings and Covers Curb and Meter Boxes Vctoiiaville. Quebec, Canada •. • Frames and Grates Proie (888) 744-6262 • Storm Inlets Fax (819) 7E-1153 • Valve Boxes, Risers, and Extensions crm-saIessigrnaco,ccm- lnnslil, Ontario, Canada • 3-64" High Hub Threaded Flanges Pho,e (8 77) 436-3800 • 348 Tapped High Hub Threaded Flanges — • 3-36' Extra Heavy 2501b Drilled Threaded Flanges Fax (705) 43!6335 . •3-48" Threaded MJ Bell Adapters cr.m-saie.9rracoccrn - • 3-48" MJ x PE Bell adapter (2ft) 3-48" Anchor Flanges 3-16" Filler Flanges -. • FLANGE-PAKT prepackaged flange accessory sets Polyethylene encasement for ductile iron pipe __________________________ - • Copper tubing products ' " - • Socket clamps and tie rod accessories Tracer wire & detectable/non-detectable marking tape - / • Pipe joint lubricant & hydraulic cement wv .sigmaco.corn : BOXLOK Valve Box Alignment Device fldCuo,s,,uObI, ,urwersl,. • Cast Iron Companion Flanges TRIM-TYTON and TYTON are registered trademarks of the United States Pipe and Foundry Company Dimensions in nces PROTECTO 401 is a registered trademark of Induron, Inc. WeIh in potrcs 16 SIGMA Corporation wwvi• cnacocom ©2011 SIGMA Corporation, All rights reserved. • Size No. Bolt Size Bolt Length *2 2 /8 3 3 4 /s 3 4 4 3/4 3½ 6 6/4 4 8 6 3/4 4 10 8 3/4 4 12 8 3/4 4 14 10 3/4 41/2 16 12 3/4 41/2 18 12 3/4 41/2 20 14 3/4 41/2 24 16 3/4 5 30 20 1 6 36 24 1 6 42 28 11/4 61/2 48 32 1¼ 6½ * Not included in AWWA Ci 10. ACCESSORIES AND WEIGHTS 140 THRU 48° GLANDS MAY Wt. of Gland, Pipe BE TAPERED Bolts and Barrel Gasket, Lbs. 0. D. 5 7 10 16 25 30 40 45 55 65 85 105 220 301 389 477 Bolt Torque Ft/Lbs. 45-60 45-60 75-90 75-90 75-90 75-90 75-90 75-90 75-90 75-90 75-90 75-90 100-120 100-120 120-150 120-150 2.50 3.96 4.80 6.90 9.05 11,10 13.20 15.30 17.40 19.50 21.60 25.80 32.00 38.30 44.50 50.80 K1 SPECIFICATION SECTION 2.3 DUCTILE IRON C1 10 FULL BODY MECHANICAL JOINT DIMENSIONS TYLER UNION® SAMPLE SPECIFICATION Mechanical Joint watermain fittings with accessories, 2" through 48" shall be produced of Ductile Iron in accordance with and meet all applicable terms and provisions of standards ANSI/AWWA Cl10/A21.10 ANSI/AWWA Cli1/A21.11 (current revi- sions). Ductile Iron Mechanical Joint Fittings 3" through 24" shall be rated for 350 PSI working pressure. All Ductile Iron Me- chanical Joint Fittings 30" through 48" shall be rated for 250 PSI working pressure. Flanged ductile-iron fittings in 24-in. (610 mm) and smaller sizes may be rated for 350 psi (2,413 kPa) with the use of special gaskets. NOTE - EXCEPTIONS: Mechanical Joint Fittings with flanged branches and 14' and larger caps and plugs are rated for water pressure of 250 PSI. NOTE: Fittings are CEMENT-LINED and seal coated in accordance with ANSI/AWWA C1 04/A21.4; also available double cement-lined, bare or epoxy coated. All coated fittings meet requirements of NSF-61. JOINT DIMENSIONS IN INCHES FOR MECHANICAL JOINT FITTINGS DIMENSIONS IN INCHES Size A B C D F ½ X J K1 K2 L M N 0 P S *2 2.50 2.50 3.39 3.50 2.61 280 3/4 4.75 6.25 6.25 .75 .62 ... .31 .63 .44 3 3.96 2.50 4.84 4.94 4.06 280 3/4 6.19 7.69 7.69 .94 .62 1.37 .31 .63 .52 4 4.80 2.50 5.92 6.02 4.90 28° /8 7.50 9.12 9.12 1.00 .75 1.50 .31 .75 .65 6 6.90 2.50 8.02 8.12 7.00 280 7/ 9.50 11.12 11.12 1.06 .88 1.63 .31 .75 .70 8 9.05 2.50 10.17 10.27 9.15 280 /8 11.75 13.37 13.37 1.12 1.00 1.75 .31 .75 .75 10 11.10 2.50 12.22 12.34 11.20 280 /8 14.00 15.69 15.62 1.19 1.00 1.75 .31 .75 .80 12 13.20 2.50 14.32 14.44 13.30 280 /8 16.25 17.94 17.88 1.25 1.00 1.75 .31 .75 .85 14 15.30 3.50 16.40 16.54 15.44 28° /8 18.75 20.31 20.25 1.31 1.25 2.00 .31 .75 .89 16 17.40 3.50 18.50 18.64 17.54 280 7/ 21.00 22.56 22.50 1.38 1.31 2.06 .31 .75 .97 18 19.50 3.50 20.60 20.74 19.64 280 7/ 23.25 24.83 24.75 1.44 1.38 2.13 .31 .75 1.05 20 21.60 3.50 22.70 22.84 21.74 280 /8 25.50 27.08 27.00 1.50 1.44 2.19 .31 .75 1.12 24 25.80 3.50 26.90 27.04 25.94 280 /8 30.00 31,58 31.50 1.62 1.56 2.31 .31 .75 1.22 30 32.00 4.00 33.29 33.46 32.17 200 1Y8 36.88 39.12 39.12 1.81 2.00 2.75 .38 1.00 1.50 36 38.30 4.00 39.59 39.76 38.47 200 1Y8 43.75 46.00 46.00 2.00 2.00 2.75 .38 1.00 1.80 42 44.50 4.00 45.79 45.96 44.67 200 1/8 50.62 53.12 53.12 2.00 2.00 2.75 .38 1.00 1.95 48 50.80 4.00 52.09 52.26 50.97 200 1/s 57.50 60.00 60.00 2.00 2.00 2.75 .38 1.00 2.20 * Not included in AWWA Cli 0. ANSI/AWWA C11O/A21.10, ANSI/AWWA C1 1/A21.11 Tyler Utilities Division • 11910 CR 492 Tyler, Texas 75706 . (800) 527-8478 02/01/08 Union Foundry Company Box 309 Anniston, Alabama 36202 . (800) 226-7601 It 1'4 V U,j *e IM ***M4" I 1flI7* I 900 Mi x Ml (1/4) 90°MIxPE (1/4) Size *2 3 4 6 8 10 12 14 16 18 20 24 30 36 42 48 R 2.25 4.0 4.5 6.0 7.0 9.0 10.0 11.5 12.5 14.0 15.5 18.5 21.5 24.5 27.5 30.5 Weights MJxPE MJxFE 36 53 80 119 181 252 470 600 775 1301 1920 2310 75 118 168 288 465 577 1150 DUCTILE IRON C1 10 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNION® Mi x FIPT ECCENTRIC REDUCER Dimensions Size L Weights 6x2 13 51 8x2 15 71 BENDS 90° Bends (1/4) Dimensions Y 3,25 5.5 6.5 8.0 9.0 11.0 12.0 14.0 15.0 16.5 18.0 22.0 25.0 28.0 31.0 34.0 Z MJxMJ 16 13.5 26 14.5 56 16.0 88 17.0 123 19.0 189 20.0 268 22.0 380 23.0 552 24.5 625 26.0 862 30.0 1423 33.0 1942 36.0 2629 3410 4595 ANSI/AWWA C1 10/A21.10, ANSI/AWWA C1 1/A21.11 Tyler Utilities Division • 11910 CR 492 • Tyler, Texas 75706 (800) 527-8478 12 Union Foundry Company• Box 309 • Anniston, Alabama 36202 . (800) 226-7601 02/01/08 450 Bends (1/8) Dimensions Weights Size R Y Z MJ MJxFE* MJxPE *2 1.96 1.8 ,.. 16 3 3.62 3.0 11.0 30 4 4.81 4.0 12.0 53 48 45 6 7.25 5.0 13.0 77 60 69 8 8.44 5.5 13.5 110 107 111 10 10.88 6.5 14.5 172 168 167 12 13.25 7.5 15.5 222 215 218 14 12.06 7.5 15.5 311 16 13.25 8.0 16.0 364 360 360 18 14.50 8.5 16.5 531 430 455 20 16.88 9.5 17.5 655 543 664 24 18.12 11.0 19.0 865 1099 825 30 27.75 15.0 23.0 1447 ... 1510 36 35.00 18.0 26.0 2435 ... 1930 42 42.25 21.0 2955 48 49.50 24.0 4080 * Not included in AWWA Cl 10. 221/20 Bends (1/16) Dimensions Weights Size R Y Z MJ MJxFE° MJxPE 3 7.56 3.0 11.0 30 4 10.06 4.0 12.0 52 6 15.06 5.0 13.0 77 71 70 8 17.62 5.5 13.5 110 107 109 10 22.62 6.5 14.5 156 155 163 12 27.62 7.5 15.5 221 215 224 14 25.12 7.5 15.5 300 16 27.62 8.0 16.0 391 315 365 18 30.19 8.5 16.5 527 422 455 20 35.19 9.5 17.5 611 ... 575 24 37.69 11.0 19.0 986 800 930 30 57.81 15.0 23.0 1898 ... 1540 36 72.88 18.0 26.0 2372 ... 1970 42 88.00 21.0 3020 48 103.06 24.0 4170 111/4° Bends (1/32) Dimensions Weights Size _R Y Z Mi MlxFE* MJxPE 3 15.25 3.0 11.0 4 20.31 4.0 12.0 6 30.50 5.0 13.0 32) 8 35.50 5.5 13.5 10 45.69 6.5 14.5 12 55.81 7.5 15.5 14 50.75 7.5 15.5 1L O1 an 1Lfl Y - 18 60.94 8.5 16.5 20 71.06 9.5 17.5 - 24 76.12 11.0 19.0 30 116.75 15.0 23.0 IRA 36 147.25 18.0 26.0 111/40 MJxFE(1/32) 42 177.69 21.0 48 208.12 24.0 ANSI/AWWA C1 10/A21.10, ANSI/AWWA C1 1/A21.11 Tyler Utilities Division • 11910 CR 492 . Tyler, Texas 75706 . (800) 527-8478 02/01/08 Union Foundry Company . Box 309 • Anniston, Alabama 36202 • (800) 226-7601 TYLER UNIONS BENDS 450 MJ (1/8) 450 MJ x PE (1/8) I 30 52 65 71 104 105 171 221 215 305 391 367 525 422 605 ... 996 800 972 1410 ... 1305 2397 ... 2185 3035 ... 4190 ... 13 DUCTILE IRON C1 10 FULL BODY MECHANICAL JOINT FITTINGS TEES NU. Bullhead .19 I n 11000~ TYLER UNION® MJ TAPPED TEE DUCTILE IRON Cli 0 FULL BODY MECHANICAL JOINT FITTINGS MJ Tapped Tee (2Tap) Size Dimensions I Max. Tap Weights 3 8 2 40 4 8 2 51 6 8 2 73 8 8 2 104 10 8 2 130 12 8 2 180 Run Size Run Branch X Dimensions Y Z MJ Weights **MJxPExMJ **MiJXFE *2 2 2 3.25 3.25 ... 21 *3 3 2 3.25 3.25 ... 45 3 3 3 5.5 5.5 13.5 58 *4 4 2 4.8 4.8 14.5 68 ... 49 4 4 3 6.5 6.5 14.5 77 4 4 4 6.5 6.5 14.5 78 75 76 4 4 6 8.0 8.0 ... 112 *6 6 2 8.0 8.0 ... 78 6 6 3 8.0 8.0 16.0 112 6 6 4 8.0 8.0 16.0 110 ... 109 6 6 6 8.0 8.0 16.0 119 120 141 6 6 8 9.0 9.0 ... 158 8 8 3 9.0 9.0 17.0 155 8 8 4 9.0 9.0 17.0 157 ... 150 8 8 6 9.0 9.0 17.0 175 170 182 8 8 8 9.0 9.0 17.0 199 180 194 10 10 4 11.0 11.0 19.0 ... ... 229 10 10 6 11.0 11.0 19.0 258 ... 264 10 10 8 11.0 11.0 19.0 268 ... 245 10 10 10 11.0 11.0 19.0 300 250 12 12 4 12.0 12.0 20.0 318 315 323 12 12 6 12.0 12.0 20.0 325 325 335 12 12 8 12.0 12.0 20.0 335 335 372 12 12 10 12.0 12.0 20.0 392 390 12 12 12 12.0 12.0 20.0 396 396 476 *16 16 4 15.0 15.0 ... 600 ... 575 16 16 6 15.0 15.0 ... 656 ... 605 16 16 8 15.0 15.0 ... 625 ... 615 16 16 10 15.0 15.0 ... 645 16 16 12 15.0 15.0 ... 715 ... 651 16 16 16 15.0 15.0 ... 780 ... 730 * Not included in AWWA C11O ** Made to order only. Not Returnable NOTICE: Weights published in this catalog are for shipping purposes only. Actual weights may vary because some fittings are produced in both foundries. All fittings meet the AWWA standards to which they are designed. For weights of specific fittings, please contact Tyler Pipe or Union Foundry Company. ANSI/AWWA C110/A21.10, ANSI/AWWA C1 i/A21.11 Tyler Utilities Division • 11910 CR 492 Tyler, Texas 75706 . (800) 527-8478 14 Union Foundry Company Box 309 . Anniston, Alabama 36202 (800) 226-7601 02/01/08 so 18 18 6 13.0 18 18 8 13.0 18 18 12 13.0 18 18 18 16.5 20 20 6 14.0 20 20 8 14.0 20 20 12 14,0 20 20 16 18.0 20 20 20 18.0 24 24 6 15.0 24 24 8 15.0 24 24 12 15.0 24 24 14 15.0 24 24 16 15.0 24 24 18 22.0 24 24 20 22.0 24 24 24 22.0 30 30 6 18.0 30 30 8 18.0 30 30 10 18.0 30 30 12 18.0 30 30 16 18.0 30 30 18 18.0 30 30 20 18.0 30 30 24 25.0 30 30 30 25.0 36 36 6 20.0 36 36 8 20.0 36 36 10 20.0 36 36 12 20.0 36 36 14 20.0 36 36 16 20.0 36 36 18 20.0 36 36 20 20.0 36 36 24 20.0 36 36 30 28.0 36 36 36 28.0 42 24 42 23.0 42 30 42 31.0 42 36 42 31.0 42 42 42 31.0 48 24 48 26.0 48 30 48 26.0 48 36 48 34.0 48 42 48 34,0 48 48 48 34.0 15.5 ... 710 ... 707 15.5 ... 674 ... 675 15.5 ... 749 ... 733 16.5 ... 945 ... 953 17.0 ... 849 17.0 ... 892 ... 859 17.0 ... 896 18.0 ... 1095 18.0 ... 1258 ... 1168 19.0 ... 1233 ... 1228 19.0 ... 1234 ... 1242 19.0 ... 1256 ... 1165 19.0 ... 1220 19.0 ... 1245 22.0 ... 1735 22.0 ... 1720 22.0 ... 1947 ... 1795 23.0 ... 2050 23.0 ... 2060 23.0 ... 2075 23.0 ... 2090 23.0 ... 2145 23.0 ... 2170 23.0 ... 2205 25.0 ... 2880 25.0 ... 2275 ... 3080 26.0 ... 2439 ... 2430 26.0 ... 2444 26.0 ... 2535 26.0 ... 2541 ... 2550 26.0 ... 2570 26.0 ... 2585 ... 2450 26.0 ... 2610 26.0 ... 2635 26.0 ... 2792 ... 2660 28.0 ... 3545 28.0 ... 3450 30.0 ... 3690 31.0 ... 4650 31.0 ... 4880 31.0 ... 6320 34.0 ... 4995 34.0 ... 5140 34.0 ... 6280 34.0 ... 8130 34.0 ... 8420 Bullhead 10000~;~ TYLER UNIONS TEES (Cont) DUCTILE IRON C1 10 FULL BODY MECHANICAL JOINT FITTINGS Size Dimensions Weights Run Run Branch X Y Z MJ **MJxPExMJ *SfrJJxFE * Not included in AWWA Cl 10 ** Made to order only. Not Returnable ANSI/AWWA C11O/A21.10, ANSI/AWWA C1 1/A21.11 Tyler Utilities Division • 11910CR 492 . Tyler, Texas 75706 . (800) 527-8478 02/01/08 Union Foundry Company• Box 309 . Anniston, Alabama 36202 • (800) 226-7601 15 Y ALL MJ DUCTILE IRON C1 10 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNION® WYES/LATERAL (Not included in AWWA Cli 0.) x Run Size Branch Dimensions X Z Weights 3 3 10.0 3.0 60 4 4 12.0 3.0 90 6 4 14.5 3.5 130 6 6 14.5 3.5 145 8 4 17.5 4.5 190 8 6 17.5 4.5 205 8 8 17.5 4.5 230 10 6 20.5 5.0 330 10 8 20.5 5.0 310 10 10 20.5 5.5 435 12 8 24.5 5.5 505 12 12 24.5 5.5 490 14 6 27.0 6.0 626 16 16 30.0 6.5 1079 18 8 32.0 7.0 1073 18 10 32.0 7.0 975 18 12 32.0 7.0 1015 18 16 32.0 7.0 1135 18 18 32.0 7.0 1130 20 10 35.0 8.0 1220 20 12 35.0 8.0 1260 20 16 35.0 8.0 1375 20 20 35.0 8.0 1525 24 24 40.5 9.0 2372 30 30 49.0 100 3670 CROSSES Size Dimensions Weights Run Branch X Y MJ SMJXFE 6 6 8.0 8.0 160 8 4 9.0 9.0 185 8 6 9.0 9.0 205 8 8 9.0 9.0 255 10 6 11.0 11.0 285 10 8 11.0 11.0 310 10 10 11.0 11.0 380 12 6 12.0 12.0 361 12 8 12.0 12.0 371 12 12 12.0 12.0 486 14 8 14.0 14.0 550 14 14 14.0 14.0 779 16 6 15.0 15.0 650 16 8 15.0 15.0 675 16 16 15.0 15.0 895 18 8 13.0 15.5 775 18 10 13.0 15.5 760 18 12 13.0 15.5 860 18 18 16.5 16.5 1140 20 8 14.0 17.0 951 20 12 14.0 17.0 977 20 16 18.0 18.0 1245 20 20 18.0 18.0 1448 24 8 15.0 19.0 1244 24 12 15.0 19.0 1326 24 16 15.0 19.0 1479 24 20 22.0 22.0 1965 24 24 22.0 22.0 2192 30 6 18.0 23.0 2085 30 12 18.0 23.0 2165 30 24 25.0 25.0 3180 30 30 25.0 25.0 3640 36 36 28.0 28.0 4370 141 182 245 360 367 373 487 655 875 Not included in AWWA Cl 10. ANSI/AWWA C1 10/A21.10, ANSI/AWWA C1 1 1/A21.11 Tyler Utilities Division • 11910 C 492 Tyler, Texas 75706 . (800) 527-8478 16 Union Foundry Company• Box 309 . Anniston, Alabama 36202 . (800) 226-7601 02/01/08 S Size Mi MI-SEB MJ-LEB PExPE FExMJ MJxFE Mi MJ-SEB MI-LEB PExPE FExMJ MJxFE '3x2 6 14 14 *4x2 7 15 15 40 7 15 15 *6x2 9 17 17 6x3 9 17 17 6x4 9 17 17 MJReducer 80 11 19 19 8x4 11 19 19 8x6 11 19 19 10x6 12 20 20 10x8 12 20 20 12x4 14 22 22 12x6 14 22 22 12x8 14 22 22 Mi Small End Bell Reducer 12x10 14 22 22 14x6 7 148 14x12 16x6 18 16x8 18 26 16x10 18 16x12 18 26 26 16x14 18 Mi Large End Bell Reducer 1 8x8 19 18x10 19 _________ 18x12 19 27 18x14 19 18x16 19 20x10 20 20x12 20 28 20x16 20 28 28 20x18 20 Plain End-Plain End Reducer 2412 24 32 24x16 24 32 32 2418 24 32 2420 24 32 32 *30x16 30 38 30x18 30 38 30x20 30 38 30x24 30 38 38 36x20 36 •.. 44 36x24 36 •.. 44 FExMJ Reducer 3600 36 44 42x24 . 42 42x30 42 42x36 42 4800 48 4806 48 48x42 48 *Not included in AWWA C1 10 MJxFE Reducer 24 24 24 31 30 31 23 7 7 37 38 37 34 34 35 46 43 47 9 55 50 55 .. .. 50 25 9 9 56 60 59 57 53 62 84 77 70 11 11 84 82 84 73 75 27 11 11 94 90 93 96 84 80 12 12 115 116 117 .. 100 105 28 12 12 142 135 130 135 130 130 139 131 .. 14 12 148 150 153 .. 145 130 30 14 12 173 168 165 168 170 175 30 14 12 194 190 178 185 188 190 16 .. .. ••• .. 195 16 215 16 .. .. ••• 270 250 .. .. 288 248 .. 300 .. 18 18 330 304 325 .. 305 325 370 .. .. 19 320 .. .. .. 300 388 .. .. 19 380 355 .. .. .. 405 450 . .. 19 476 .. .. ••• ..• 445 410 .. 515 420 .. 20 578 525 510 .. .. 510 575 ••. .•. 24 610 570 .. .. ••. 455 705 665 753 789 720 .. 815 775 804 46 .. 1150 1040 1015 46 .. 1160 1050 1025 46 .. 1225 1120 1090 46 1360 1255 1320 1215 1495 ••. 1466 52 .. .. 1580 .. 1535 1389 52 .. .. 1919 1721 .. 1585 2060 .. ••• 2370 .. ••• 2695 .. ••• ••. 3005 .. .. ••• 3370 .. .• 3750 .. ••• 1100 TYLER UNION REDUCERS Laying Lengths (L) DUCTILE IRON C1 10 FULL BODY. MECHANICAL JOINT FITTINGS Weights ANSI/AWWA C1 10/A21.10, ANSI/AWWA C1 1 1/A21.11 Tyler Utilities Division • 11910 CR 492 . Tyler, Texas 75706 . (800) 527-8478 02/01/08 Union Foundry Company • Box 309 Anniston, Alabama 36202 • (800) 226-7601 17 ADAPTERS MJ x FE Dimensions Size I Weights - 3 8 30 4 8 42 6 8 62 8 8 88 10 8 120 12 8 150 16 8 257 18 8 324 20 8 365 24 8 528 30 10 760 36 10 1070 DUCTILE IRON C1 10 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNIONS SOLID SLEEVES Standard Pipe Short Long Size 0. D. L Weight I Weight *2 2.50 8.0 13 12 18 3 3.96 7.5 ... 12 36 4 4.80 7.5 35 12 47 6 6.90 7.5 45 12 65 8 9.05 7.5 65 12 90 10 11.10 7.5 85 12 115 12 13.20 7.5 120 12 136 16 17.40 9.5 206 15 281 18 19.50 9.5 246 15 362 20 21.60 9.5 275 15 404 24 25.80 9.5 360 15 540 30 32.00 15.0 745 24 1085 36 38.30 15.0 1047 24 1502 42 44.50 ... ... 24 1550 48 50.8 ... ... 24 1940 Not included in AWWA Cl 10 * Dual Purpose t Pipe Short Long Size O.D. I Weight I Weight 4 4.80/5.00 7.5 33 12 44 6 6.90/7.10 7.5 46 12 63 8 9.05/9.30 7.5 65 12 88 10 11.10/11.40 ... ... 12 111 t12 13.20/13.50 ... ... 12 221 t16 17.40/17.80 ... ... 15 385 All Sizes Use MJ Dual Purpose Gland * Not included in AWWA C110 f 12 & 16 are sold assembled NOTE: Sizes 4-10 use standard MJ Gaskets; 12 and 16 require special duo gaskets. * MJ x PE DUAL-PURPOSE CUTTING-IN SLEEVE With Dual-Purpose Accessories (NOTES: Gland with cup-joint set screws available at extra cost when specified. NOT FOR RESTRAINT.) Currently, Tyler and Union Dual Purpose Glands are NOT interchangeable. Sleeve &Gland D ___ LL. Weight For Use Gland Gland Size On Pipe O.D. L 11 D Only & Sleeve 4 4.80 -5.00 12 8 4.80 6.0 72 6 6.90 -7.10 12 8 6.90 10.0 94 8 9.05 -9.30 12 8 9.05 16.0 122 10 11.10-11.40 12 8 11.10 25.0 175 12 13.20 - 13.50 12 8 13.20 30.0 235 * Not included in AWWA Cl 10. ANSI/AWWA C110/A21.10, ANSI/AWWAC111/A21.11 Tyler Utilities Division • 11910 C 492 Tyler, Texas 75706 . (800) 527-8478 18 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 02/01/08 Solid or Tapped Weight Size Tap Solid Tapped *2 2 5 .5 3 2 9 9 4 2 13 14 6 2 15 15 8 2 45 45 10 2 66 66 12 2 79 79 14 2 120 120 16 2 147 147 f18 2 192 190 t20 2 220 219 f24 2 338 338 f30 2 660 660 f36 2 838 838 42 .. 1180 48 .. 1455 t Dished - Not flat as shown. * Not included in AWWAC110. Solid or Tapped Weight Size Tap Solid Tapped *2 2 6 3 2 10 10 4 2 18 13 6 2 34 30 8 2 46 45 10 2 58 54 12 2 86 80 16 2 178 175 f18 2 215 215 f20 2 250 249 t24 2 370 370 f30 2 680 680 t36 2 850 850 42 .. 1180 48 .. 1595 fDished - Not flat as shown. * Not included in AWWA C1 10. 1 D I- MJxMJ MixPE Dimensions Weights Size D L1 L MJXMJ MJxPE 4 6 19 27 ... 82 4 12 22 30 85 80 4 18 30 38 105 *4 24 26 34 126 125 6 6 20 28 114 105 6 12 26 34 148 143 6 18 33 41 188 176 *6 24 24 32 182 160 8 6 21 29 177 155 8 12 28 36 231 195 8 18 35 43 287 282 *8 24 36 44 280 285 10 12 30 38 347 280 10 18 38 46 340 340 10 24 38 46 420 12 12 37 45 420 420 12 18 48 56 520 520 *12 24 48 56 649 630 16 12 40 48 715 16 18 50 58 850 830 *20 12 40 48 1025 *20 18 48 60 1362 * Not included in AWWA C11O. DUCTILE IRON C1 10 FULL BODY MECHANICAL JOINT FITTINGS TYLER UNION17 PLUGS CAPS OFFSETS TYTON® Plug** Solid or Tapped Size Tap T Weight* 4 2 .60 18 6 2 .65 25 8 2 .70 46 10 2 .75 70 12 2 .75 95 . * Weights do not include accessories ** Not included in AWWA Cl 10. TYTON® is a registured trademark of U.S. Pipe and Foundry Company. Solid Tapped Push-In Plug with Ears (To be used with all push-in pipe and fittings) Size Tap Weight 14 2.0 101 16 2.0 137 18 2.0 177 t20 2.0 239 t24 2.0 311 f Dished - Not flat as shown NOTE: Blocking still required- ears for assembly only. ANSI/AWWA C110/A21.10, ANSI/AWWA C1 1/A21.11 Tyler Utilities Division • 11910 CR 492 . Tyler, Texas 75706 (800) 527-8478 02/01/08 Union Foundry Company • Box 309 . Anniston, Alabama 36202 • (800) 226-7601 19 S Gland Weight Size Wt. Pack Gland Only 2 5 3 3 7 4 4 10 6 6 16 10 8 25 16 10 30 19 12 40 26 14 45 34 16 55 54 18 65 52 20 85 73 24 105 91 30 220 90 36 301 127 Mi x Mix Swivel Dimensions Size X Y Weight 6 8.0 10.5 150 8x6 9.0 11.5 199 8 9.0 11.5 210 10x6 11.0 13.5 267 12x6 12.0 14.5 346 16x6 15.0 17.5 619 16x8 15.0 17.5 649 30x6 18.0 24.5 2070 TYLER UNION" *RETAINER GLAND ASSEMBLY DUCTILE IRON C1 10 FULL BODY MECHANICAL JOINT FITTINGS Pipe Wall Thickness: Sizes 3-12 are recommended for ductile iron pipe class 50 thru 56. Sizes 14 thru 24 are recommended for ductile iron pipe class 53 thru 56. U.' DUCTILE IRON RETAINER GLANDS See Installations Instructions................................................... Page 50 Pressure Gland Pipe O.D. D.I. Pipe No of Size of Rating, O.D. O.D. Wall Set Set Gland Weight Size psi B A Class Screws Screws Weight w/Acces. 3 350 7.69 3.96 50-56 4 5/8x2 4 8 4 350 9.12 4.80 50-56 4 5/8x2 5 11 6 350 11.12 6.90 50-56 6 5/8x2 9 16 8 250 13.37 9.05 50-56 9 /sx2 13 21 10 250 15.62 11.10 50-56 12 5/8x2 17 26 12 150 17.88 13.20 50-56 16 5/sx2 20 28 14 250 20.25 15.30 53-56 20 5/8x2½ 44 55 16 200 22.50 17.40 53-56 24 %x21/2 54 64 18 200 24.75 19.50 53-56 24 5/sx2½ 62 72 20 200 27.00 21.60 53-56 28 5/ax3 76 91 24 150 31.50 25.80 53-56 32 5/8x3 103 118 * Not included in AWWA Cli 0 TEES Mechanical Joint Retainer Glands are designed to provide a method for restrain- ing mechanical joint pipe and fittings and other standardized mechanical joints against possible joint separation, rupture or blow-out caused by internal water pres- sure. The set screws are square-headed with Type C knurled cup points, and are shipped already assembled in the Glands. They are manufactured of 4140 grade alloy steel, and are heat treated to a Rock- wall "C" 45/53 case hardness. Tee-head bolts and gaskets are not included, but may be ordered separately. Recommend- ed torque for set screws is 75 foot pounds, and set screws on opposite sides of the glands should be tightened alternately. Tee-head bolt hole size and spac- ing are equal to Mi Glands as shown in AWWA C-i 11. Standard mechanical Joint gaskets as shown in C-i 11 should be used. Mi GLAND All weights shown include the Swivel Gland ANSl/AWWAC110/A21.lO, ANSI/AWWAC111/A21.11 Tyler Utilities Division • 11910 CR 492 Tyler, Texas 75706 . (800) 527-8478 20 Union Foundry Company• Box 309 • Anniston, Alabama 36202 . (800) 226-7601 02/01/08 TYLER UNION® DUCTILE IRON C1 10 FULL BODY MECHANICAL JOINT ELLS, ADAPTERS AND GLANDS For Valve and Hydrant Connections ADAPTERS Swivel x Solid Adapter —VARIABLE __ Size by Wall - Laying Length Thickness Weight 4x13 .52 52 6x12 .55 84 6x18 .55 91 6x24 .55 105 606 .55 156 8x13 .60 126 12x13 .75 186 Weights with Gland. ELLS *900 Swivel x Swivel Ell (Not Included In AWWA Cli 0) Wall Dimensions Size Thickness A B C D E F R Weight 6 .55 10.5 15.5 7.10 11.12 6.90 8.02 6.0 106 8 .60 11.5 16.5 9.20 13.37 9.05 10.17 7.0 156 * With 2 Swivel Glands SWIVEL GLAND ASSEMBLY Used with swivel fittings, the TYLER Swivel Gland, with its rotating feature, permits the installer to meet any grade require- ments regardless of bolt-hole alignment. In addition, the system permits stiff connections without braces, blocking or strapping. Swivel Glands** ANSI/AWWA C110/A21.10, ANSI/AWWA Cli 1/A21.11 Tyler Utilities Division • 11910 CR 492 Tyler, Texas 75706 (800) 527-8478 Union Foundry Company. Box 309 • Anniston, Alabama 36202 • (800) 226-7601 21 Size Weight 12 30 ** Not included in AWWAC11O. NOTE: When ordering glands separately, Specify TYLER UPCode Number, Description, and Size of fitting to be joined. MEETS AWWA 0900 AND ASTM D1784 CELL CLASS 12454; GASKETS MEET ASTM F477; JOINTS MEET ASTM D3139. Building essentials for a better to,norrow' SPECIFICATION SECTION 2.3 !J[iI[iJF JM Eagle's Blue Brute C900 pipe is suitable for use in distribution pipelines of potable water, as well as gravity sewer, force main and water reclamation projects. JM Eagle Blue Brute C900 is available in 4- through 12-inch diameters, in blue, white, purple and green. It comes in standard laying lengths of 20 feet. One length of 8-inch DR 18 pipe weighs approximately 184 pounds The pipe conforms to AWWA C900 pressure class 165 psi (DR 25), 235 psi (DR 18) and 305 psi (DR 14). It carries approval of ANSI/NSF Standard 61, UL 1285 and FM 1612 (DR 18 and DR 14 only). BENEFITS JM Eagle Blue Brute C900 pipe is the safe, long-lasting and stable solu- tion for a modern infrastructure. Blue Brute: Maintains performance against tuberculation, corrosion and external gal- vanic soil conditions without lining wrapping, coating or cathodic protection. Keeps its smooth interior over long years of service with virtually no loss in carrying capacity, allowing for savings in pumping costs, as well as say- ings on the size of the pipe required. Can be field-cut with a power saw or ordinary handsaw and be beveled without the use of expensive or complicated machinery. P1 EASF—CQN.TACT-Y.0,URJ.M.EAGLE-BERFIESENTATIV.E,OR-VISJ.T-W WW-JM EAGLE..COM-F-OR-M,QRLl.REOB,MATION PIPE SIZE (IN) AVERAGE O.D. (IN) NOM. I.D. (IN) MIN. T. (IN) MIN. E (IN) APPROX. D9 (IN) WEIGHT (LBS/F'i PRESSURE CLASS 165 psi (DR 25) 4 4.80 4.39 0.192 5.25 5.57 1.9 6 6.90 6.31 0.276 6.40 8.00 3.9 8 9.05 8.28 0.362 7.05 10.50 6.7 10 11.10 10.16 0.444 8.20 12.88 10.1 12 13.20 12.08 0.528 8.80 1 15.31 14.4 PRESSURE CLASS 235 psi (DR 18)* 4 4.80 4.23 0.267 5.25 5.87 2.6 6 6.90 6.09 0.383 6.40 8,43 5.3 8 9.05 7.98 0.503 7.05 11.06 9.2 10 11.10 9.79 0.617 8.20 13.57 13.9 12 13.20 11.65 0.733 8.80 16.13 19.7 PRESSURE CLASS 305 psi (DR 14)* 4 4.80 4.07 0.343 5.25 6.17 3.2 6 6.90 5.86 0.493 6.40 8.87 6.7 8 9.05 7.68 0,646 7.05 11.63 11.6 10 11.10 9.42 0.793 8.20 14.27 17.6 12 13.20 11.20 0,943 8.80 16.97 25.1 S JMagIe Building essentials for a better tomorrow" JI1 __J.1w• - 0 Is, I I *I* * , Consult JM Eagle' for CSA and other listing availability prior to shipment. Note: *FM Approvals Pressure Class 150 psi for DR 18 and 200 psi for DR 14. * Contact your JM eagleTM sales representative for location availability. 1 T/ E O.D. Assembly Mark I.D. Inside Damoter OD. Outside Diameter 1P T. Wall Thickness D9 Bell Outside Diameter E: Distance between Assembly Mark to the end of spigot. Product Standard: ANSI/AWWA 0900 Certifications: ANSI/NSF Standard 61 Pipe Compound: ASTM Dl 784 Cells Class 12454 UL Standard 1285 Gasket: ASTM F477 Pipe Length: 20 feet laying length Integral Bell Joint: ASTM D3139 Installation: AWWA C605 JM EagIe Installation Guide * Tru-Dual Inserts are heat treated for hardness to ensure proper restraint on ductile iron pipe. **Two inserts are located near the clamp points on each half of the split serrated ring. This design provides maximum restraint on both ductile iron pipe and C900 P VCpipe enabling the product to he truly Tru-Dual. - 15MJ 04TD 'ii 150 100 ; 15MJ06TD 12.7 : • 200 150 100 VISM108TD 16.7 250 'ii 150 100 10 D 33.0 ' 'is 150 100 12 15 lvi I -I 'I 'Ii 150 100 CD H'Series 15MJOOTP Restraint for Ductile Iron Pipe or C900 PVC Pip '-at SPECIFICATION SECTION 23 Mechanical Joint Fittings Features and Applications: Restraint for Ductile Iron Pipe at ductile iron fittings, meeting ANSI/AWWA C151/A21.51 and ANSI/AWWA C150/ A21.50 Restraint for AWWA C900 PVC Pipe at ductile iron fittings Minimum 2 to I Safety Factor Series I5MJ06TD restraining both ductile iron pipe and C900 P VCpipe at a Mi fitting with anM.J gland. MEGA-BOND Restraint Coating System For more on MEGA-BOND refer to www.ebaa.com Constructed of ASTM A536 Ductiln For use on water or wastewater pipelines subject to hydrostatic pressure and tested in accordance with either AWWA C600, C605, or ASTM D2774. Sample Specification Restraint for mechanical joints on AWWA C900 PVC pipe and Ductile Iron pipe systems shall consist of the following: The restraint shall be manufactured of ductile iron conforming to ASTM A536. A split, serrated ring, with a sufficient number of heat treated Tru-Dual inserts for gripping both Ductile Iron Pipe and PVC pipe, shall be utilized to grip the pipe in conjunction with a sufficient number of bolts connecting the serrated restraint to the joint. The restraint devices shall be coated using MEGA-BOND®. (For complete specifications on MEGA-BOND visit www.ebaa.com.) The restraint for mechanical joint fittings with mechanical joint glands shall be the Tru-Dual Series 15MJOOTD, both as manufactured by EB. on, Inc., or approved equal. 1113- LS-E ConyTight © 2013 EBAA Iron. Inc. Reference Drawing I 0 w .4 a pv.-- 1 15 M 3001 D fr1cArc .o Dt Ht U11 I 3/4'1rh m Be . :, 4 15MJ04TD 4.80 9.25 1.25 6 2 7.5 6 15MJ06TD 6.90 11.25 163 6 2 9.5 8 15MJ08TD 9.05 14.75 1.63 6 2 11.32 - 13.00 10 15MJ1OTD 1140 - 16,85 215 6 4 13.48- 14.94 15M.11210 1310 19.45 2.15 6 4 15.94-17.63 Installation Instructions ___ th C900 PVC Pipe and Ductile Iron Pipe I.W.tify the pipe. The Series 15MJOOTD is designed for restraining C900 PVC and Duct:Ie Iron pipe at ductile iron Mechanical Joint (MJ) fittings with MJ glands (sipplied by others). The restraint is a spli:, serrated ring installed behind the MJ glard. The 15MJOOTD utilizes longer t-Bolts than the standard MJ t-Bolt lengths to facilitate the restraint position. ?. Set aside the split restraint and Ic iger bolts and install the Mi gland per AWWA C600. The bolt torques for 4 inch through 12 is 75-90 ft-lbs. The use of a torque-indicating wrench will facilitate the procedure. Members of... WNW— AMERICN FOUNDRY 000JOIF EBAA IRON Sales, Inc. P.O Box 857 EasUand,104* Tel: (254) 629-1731 Fax:(254)629-8931 (800) 5331716 within US and Canada contact@ebaa.com v.ebaa,com Using a longer bolt as a gauge, place one half of the restraint onto the pipe so the bolt holes of the restraint and the MJ gand algn. Allow enough room on the longer bolts to fully engage the nuts with several threads showing. Install the second half of the restainttc align with the first. Tapping each half intc place may be necessary. Befcre installing the side bolts double check the position by using the longer bolts as gauges. Make sure the ID of the restraint is touching the pipe. S de bolts are to be evenly tightened to 110 ft-lbs of torque (60 ft-lbs on 4 inch and 5 inch). A torque indicating wrench will help facilitate this. Each of the longer bolts should have two nuts: one to tighten against the MJ gland and one to snug up against the restraint ring with a few threacs showing. One at a time, remove a shorter bolt that aligns with the restraint bolt hole and replace with the onger bolt remei,berir:gto "run" one nut up to engage against the MJ gland. This nut should be to the same torque as the original one removed (see step 2 for torque values). Do this for all remaning bolts holes of the restraint. Once all bolts are in place and the MJ gland nuts have been retightened to torque, put the remaining nuts on the bo t behind the restraint. Hand tighten the nits behind the restraint. Do not over tighten the nuts be,ind the restraint to move the plai-end of the pipe further into the joint. Future" SPECIFICATION SECTION 23 Series 1100 0 Mechanical Joint Restraint for Ductile Iron Pipe Features and Applications: Sizes 3 inch through 48 inch Constructed of ASTM A536 Ductile Iron Torque Limiting Twist-Off Nuts MEGA-BOND® Restraint Coating System For more information on MEGA-BOND, refer to www.ebaa.com The Mechanical Joint Follower Gland is incorporated into the restraint Heavy Duty thick wall design 3 1103 6.1 30 350 [ 4 1104 7.7 30 350 1 6 1106 11.9 30 350 8 1108 14.8 30 350 I 10 1110 23.9 3 0 350 L 12 1112 31.2 30 350 1 14 1114 48.5 2 0 350 16 1116 56.4 2° 350 J 18 1118 63.1 1½° 250 20 1120 72.3 11/2 0 250 1 24 1124 133.1 11/2 0 250 1 30 1130 1946 10 250 36 1136 234.0 10 250 1 42 1142 536.0 1° 250 I 48 1148 653.0 1° 250 Support Products Available: Split repair style available 3 inch through 48 inch. EBAA Series IIOOSD Solid restraint harness available for push-on pipe bells. EBAA Series 1700 Split restraint harness available for existing push-on bells. EBAA Series IIOOHD All MEGALUG and related restraint products can be furnished as packaged accessories complete with appropriate restraint, gasket, lubrication, and bolt- ing hardware For use on water or wastewater pi-De- lines subject to hydrostatic pres and tested in accordance with either AWWA C600 or ASTM D2774 Made In U.S. Patent Nos. 4092036, 4627774, 4779900, 4896903, 5544922 The USA MEGALUG: THE PRODUCT OF PREFERENCE SINCE 1984 Since 1984, engir.eers and contractors designing ard installing and wastewater pipelines and systems have come to rely EBAA Series 1100 MEGALUG Mechanical Jont Restraint S e "Product of Preference" for effectively and econorically estaining ductile iron pipe conrections above or below gcund. MEGALUG Mechanical Joint Restraints replace externa re- such as cumbersome concrete thrust blocks arid corrod- :le metal tie rods creating a quicker, safer and mo-c economical istallation. Major testing laboratories agree as the 3" through 24" sizes are Underwriters Laboratories (UL) listed, and the 3" through 12" sizes are Factory Mutual (FM) approved. For use on all classes of ductile iron pipe (PC350 through PC150 and CL56 through CL50), for practically any application including valves, hydrants and pipe, the V1EGLUG Mechanical Joint Restraint effectively and safely performs without damage to the pipe or cement linings. THE MEGALUG GRIPPING WEDGE... PERFORMANCE PROVEN The wedge style MEGALUG design reacts C the amount of force acting on the joint. 'hen each wecge is set, the wedge teeth enetrate the oipe's outer surface, and he wedge does not move on the pipe. here is very little cnange in this nterface intl the wedge movement begins inside e pocket of the main casting. Once the edge starts moving, the formation of the utzress begins. This "dam" of raterial (the wedge impression) is coki formed as the wedging :ction continues If the force of pressure on the join: is released, the wedge n s back to near its original position. his engages tie reserve-controlLed move- neit or "RCM". The wedge is then ready or another rovid. Ater the wedge has moved to the back LLI / Max pressure cc ement 2 cilusm wedges to I :::e::::: am LU w Z Wedge movement begins 'D Normal oparsting pressure U) w I :RCM MOVEMENT of the pocket at the maximum pressure or load, the dge buttress are in shear. The maximum movement is about 0.3 inch through the thirty-six inch size and 0.4 inch for foci-two and forty-eight inch. The RCM. is available even with severe cyclic loads. This ias been tested to very high-pressure different als and the wedge impressions lookthe same as if a single test had been performed. Typically, the depth of oipe wall pen- etration, or wedge impression at around 25,000 pounds of force per wedge (200 PSI on a six inch and 150 PSI on a twelve inch) is 0.03". Finally, at roughly twice that force the penetration is around 0.05" At these high pressures, there is no affect on the design thickness of ductile iron pipe made according to AWWA C150. The lack of damage tc the cement lining clearly indicates that the thrust load is primarily longitudinal. This ability to move in the pocket allows for angular flexibility as well as longitudi- nal flexibility. THE ORIGINAL PATENTED GRIPPING WEDGES Since 1964 EBAA Iron has respond- much as allowed ed aggressively to the needs of the by the mechanical water industry for better solutions joint during installa- to joint restraint problems - thus the tion it can also deflect development of the family of self after assembly: actuating MEGALUG wedge action [ Sizes of 12" and below are restraints. capable of upto3degrees - ofdeflectionafterinstallation TOOLS (depending on the preset deflec- MEGALUGS install using an ordinary tj011.) wrench (box, ratchet, or air-driven), The 14" and 16" sizes are capable because the torque-limiting, twist- : of 2 degrees deflection. off nuts automatically shear during The 18" through 24" sizes are capable of - tightening when the proper torque -; 1.5 degrees deflection. 1) is reached. The same 1¼ wrench - : The 30" through 48" sizes are capable of I used to tighten the 1-bolts on the degree deflection. 4" through 24" sizes can be used to tighten and shear the twist off STEEL PIPE nuts in all sizes. If removal becomes The 1100 Series MEGALUG can be used to restrain necessary, a 5/8 hex head remains 3" - 8" SCH 40 or 80 steel pipe when joining to me- so the screws can be loosened, chanical appurtenances. It can also be used on steel and retightened with a torque-in- pipe in all sizes if the pipe's outside diameter is the dicating wrench. During removal, same as the ductile iron pipe and its thickness is equal the wedges are held in place by / to or greater than PC350 ductile iron pipe in sizes of 16 retainer clips. / inch and below and PC250 ductile iron pipe 18 inches / I \ and above. DEFLECTION The MEGALUG gripping wedges provide resiliency to your pipeline design. In addition to deflecting as CAST IRON PIPE Grey iron pipe diameters are often larger than duc- tile iron pipe diameters. The Series 1100 MEGA- LUG restraint may be used with grey iron pipe \ having standardized cast iron O.D. per AWWA C150 and C151, and with pit cast Classes "A" and "B" without modification. Use of the Series 1100 with pit cast grey iron Classes C" and "D' will require over sizingthe MEGALUG. More information on this is explained in detail in "Connections Bul- letin Dl-1". MEGALUG Takes the Load On April 11, 1997 EBAA Iron performed a remark- able force demonstration of their series 1100 MEGALUG Joint Restraint. With the use of EBAAs Series 1100 MEGALUG using a standard mechanical joint installation on 12 inch Ductile Iron Pipe, and a 80 Ton mo- tor crane, EBAA Iron lifted aD7 CaterpUlar Track Type Tractor weighing in at 50,350 lbs. Along with this, the Series 1100 MEGALUG has been tested to over 700 PSI. Concluding that EBAA's MEGALUGS can take the load. Series IIOOHDI Split MEGALUG Restraint Harness for Existing Push-On Bells llecliaflicariOifltReStraintsam k (The text of the specifications below can be copied pasted from www.ebaa. mt devices for mechanical joint fittings and appurtenances conforming to either ANSI/AWWA C111/ L or ANSI/AWWA C153/A2153, shall conform to the following: estraint devices for nominal pipe sizes inch through 48 inch shall consist of LItiple gripping wedges incorporated into follower gland meeting the applicable re- iirements of ANSI/AWWA C110/A21.10. devices shall have a working pressure ng of 350 psi for 3-16 inch and 250 psi 18-48 inch. Ratings are for water pres- e and must include a minimum safety of2to Un all sizes. land body, wedges and wedge actuating )mponents shall be cast from grade 65- 5-12 ductile iron material in accordance ith ASTM A536, r applications requiring restraint 30 ch and greater, an alternate grade of .i meeting the material requirements of TM A536 is acceptable, providing the vice meets all end product performance iectile iron griDping wedges shall be heat eated within a range of 370 to 470 BI-IN. ree (3) test bars shall be incrementally red per production shift as per Under- iter's Laboratcry (U.L.) Specifications ci ASTM A536. Testing for tensile, yield ci elongatior shall be done in accor- nce with ASM E8. nica- and nciularity tests shall be )rmed as recommended by the Ductile Society, on a per ladle basis. Traceability An identification number consisting of year, day, plant and shift (YYDDD)(plant :designation)(Shift number), shall be cast into each gland body. lAll physical and chemical test results shall be recorded such that they can be ac- cessed via the identification number on the casting. These Material Traceability Records (MTR's) are to be made avail- able, in hard copy, to the purchaser that requests such documentation and submits his gland body identification number. Production pieces that are too small to ac- commodate individual numbering, such as fasteners and wedges, shall be controlled in segregate inventory until such time as all quality control tests are passed. These component parts may then be released to a general inventory for final assembly and packaging. All components shall be manufactured and assembled in the United States. The purchaser shall, with reasonable notice, have the right to plant visitation at his/her expense. Installation Mechanical joint restraint shall require conventional tools and installation proce- dures per AWWA C600, while retaining full mechanical joint deflection during assem- bly as well as allowing joint deflection after assembly. Proper actuation of the gripping wedges shall be ensured with torque limi:ingtwistj off nuts. Approvals I Restraint devices shall be Usted by under- writers Laboratories (3" through 24" inch size) and Approved by Factcry M tual (3" through 12" inch size). Mechanical joint restraint for ductile Iron pipe shall be Megalug Series 1100 pro- duced by EBAA Iron Inc. or approved equ MEGABOND® Restraint Coating Systei All wedge assemblies ar.d related parts shall be processed through a phosphate wash, rinse and drying operation prior to coating application. The coatirg shall consist of a minimum of two coats of liqi thermoset epoxy coating with heat cure follow each coat. All casting bodies shall be surface pre- treated with a phosphate wash, rinse and sealer before drying. The coating shall be electrostatically applied and hew cured. The coating shall be a polyester based powder to provide corrosior., impact and UV resistance. The coating system shall be MEGA-BOND by EBAA Iron, Inc. or approved equal. Requests for approved equal must submit coating material and process details for review prior to bid. For more inform 1Q11 regarding QN fcr to t 4-BOtL 5roçbrc çri5it Support Products for more information concerning these products please consult the catalog or www.ebaa.com es IIOOSD [EGALUG Restraint isting,Mechanical Joints Series 1700 Series IIOOSDB Split MEGALUG Restraint For Mid-Span Applications 6W L MEGALUG Restraint Hames For Push-On Bell Joints 0.75 0.75 2 J 0.125 -H SECTION A-A Series 1100 Submittal Reference Drawing in z C to 30 3 1103 4.48 2.27 4.06 062 9.06 0.750 6.19 7.69 2 4 6.1 350 4 1104 5.92 2.27 4.90 '0.75 9.90 0.875 7.50 9.12 2 4 7.6 350] 6 1106 8.02 2.27 7.00 0.88 12.00 0.875 9.50 11.12 3 6 11.8 350 L 8 1108 10.17 2.31 9.1k 1.00 14.15 0.875 11.75 13.37 4 6 14.9 350 1 10 1110 . 12.22 2.37 11.20 1.00 16.20 0.875 14.00 15.62 6 8 . 23.9 350 L 12 1112 14.32 2.37 13.30 1.25 18.30 0.875 16.25 17.88 8 8 31.2 OJ 14 1114 16.40 2.69 15.44 1.50 20.94 0.875 18.75 20.25 10 10 49.7 0 [ 16 1116 18.50 2.69 17.54 1.56 22.90 0.875 21.00 12.50 12 12 56.4 350 1 18 1118 20.60 2.69 19.64 1.63 25.00 0.875 23.25 24.75 12 12 63.6 250 L20 1120 2270 269 2174 169 2710 0.875 2550 2700 14 14 710 250 1 24 1124 26.90 3.20 25.94 1.81 32.64 0.875 30.00 31.50 16 16 128.7 250 1 30 1130 33.29 3.20 32.17 2.25 38.87 1.125 36.88 39.12 20 20 190.7 250 1 36 1136 39.59 3.20 38.47 2.25 45.17 1.125 43.75 46.00 24 24 226.5 250 [ 42 1142 45.79 4.56 44,67 3.88 55.57 1.375 50.62 53.48 28 28 518.9 250 1 48 1148 52.09 4.56 50.97 3.88 61.87 1.375 57.50 60.36 32 32 608.3 250 A I I K The S GtLlJnirr.1 he 1.Edn 13tflcnd • EtArr.V M(;cl JcThtTh ket ro with 3G inch Through 46 Inch MG.ALUG rstirts mth qiVedn th ier'pcd sIzer o orrn tc.t pre rs .'-...; •. - ................................... ,- .. .. ken rt cito traienthT.yIl C pf iawi i-ti4 'crttwct pci frFit' a1e i &riLh rnhri1 Aj FQr tet Ile the rHte esuc.s Dwr co i ror AiJ Sers 1UO c'TpunrILs f1ctefdut ile t SUC tul .e for L cQ'o.rnugtu AS A. I are tP1 to a ss r *1 - der{14 ir.oh TI J ççr is CX2. r Sizes 3 u.rh th cun 12 rha fr4o'y Mitrorii Th J! ALUn1ThJi for u. i dcto iror ppe Th 4tr&nt ki usfd rca pi hs er c(c r nt r th c&h1i cLfk cIoij et i 4 1. The Series 1100 MEGALUG joint re- straint is designed for use on ductile iron pipe conforming to ANSI/AWWA C151/A21.51 (all thickness classes) when restraining mechanical joint pipe fittings. 2.* Clean the socket and the plain end. Lubrication and additional cleaning should be provided by brushing both the gasket and the plain end with soapy water or an approved pipe lubrication meeting the requirement of ANSI/AWWA C111/A21.11, 4. (cont.),,, I 5* Tighten the bolts to the normal range of torque as indicated [3 inch 45-60 ft-lbs., 4-24 inch 75-90 ft- lbs., 30-36 inch 100-120 ft-lbs., and 42-48 inch 120-150 ft-lbs.] While at all times maintaining approximately the same distance between the gland and the face of the flange at all points around the socket. This can be accomplished by partially tightening the bottom bolt first, then top bolt, next the bolts at either side, finally the remaining bolts. Repeat the process until all bolts are within the appropriate range of torque. just prior to slipping the gasket onto the plain end for joint assembly. Place the gland on the plain end with lip extension toward the plain end, followed by the gasket. NOTE: In cold weather it is preferable to warm the gasket to facilitate assembly of the joint. 3* Insert the pipe into the socket and press the gasket firmly and evenly into the gasket recess. Keep the joint straight during assembly. S.). In large sizes (30-48 inch), five or more repetitions may be required. The use of a torque-indicating wrench will facilitate this procedure. 6. Tighten the torque limiting twist- off nuts in a clockwise direction (direction indicated by arrow on top of nut) until all wedges are in firm contact with the pipe surface. Continue tightening in an alternat- ing manner until all of the nuts have been twisted off. EBAA IRON Sales, Inc. P.O. Box 857, Eastland, IX 76448 Tel: (254) 629.1731 Fax: (254) 6298931 (800) 433.1716 within US and Canada contact@ebaa.com www 11hign 4. 4* Push the gland toward the socket and center it around the pipe with the gland lip against the gasket. Insert bolts and hand tighten nuts. Make deflection after joint assembly but before tightening bolts. 6. j4& 7. If removal is necessary, utilize the /8 inch hex heads provided. If reas- sembly is required, assemble the joint in the same manner as above, by tightening the wedge bolts to 90 ft-lbs. If the series 1100 restraint is removed from the pipe, be sure that all the collar bolts and wedges are in place before the restraint is reassembled. * These steps are requirements of AWWA. AWWA Standard C600 For More Information For more information about MEGALUG restraints call EBAA today and request "EBAA Connections Bulletin Dl-1" concerning use of the MEGALUG restraint on grey iron pipe, or "EBAA Connections Bulletin Dl-2" covering the background and operation of the MEGALUG system of restraint. Restraint Length Calculation" Software is available for PC/Windows applications. Support documenta- tion about the software can be found in "EBAA Con- nections Bulletin PD-1 through PD-5". 1 A 3 7.69 6.19 7.62 2.50 5/8 x 3 4 11/16 45-60 ft-lbs 8° - 18' 31 Mechanical Joint Ductile Iron Pipe The mechanical joint is a bolted joint utilizing a ductile iron gland and mechanical joint gasket. The mechanical joint is recom- mended for water service using ductile iron pipe particularly where many connections are required. All components of the mechanical joint are interchangeable. The plain end of mechanical joint pipe has the same outside diameter as push-on joint pipe. As a result, it can be fitted into such joints in the field by beveling the plain end. All of the accessories (glands and fasteners) are supplied with each joint. 4 9.12 7.50 9.06 2.50 3/4 x 3-1/2 4 11/4 75-90 ft-lbs 80 - 18' 31 6 11.12 9.50 11.06 2.50 3/4 x 3-1/2 6 11/4 75-90 ft-lbs 7° - 07' 27 30 8 13.37 11.75 13.31 2.50 3/4x4 6 11/4 75-90ft-lbs 5°-21' 20 22 10 15.62 14.00 15.62 2.50 3/4 x 4 8 11/4 75-90 ft-lbs 50 - 21' 20 22 12 17.88 16.25 17.88 2.50 3/4x4 8 11/4 75-90ft-Ibs 5°-21' 20 22 14 20.25 18.75 20.25 3.50 314x4-1/2 10 11/4 75-90ft-Ibs 3035 13.5 15 16 22.50 21.00 22.50 3.50 3/4x4-112 12 1/4 75-90ft-lbs 3°-35' 13.5 15 18 24.75 23.25 24.75 3.50 3/4x4-1/2 12 11/4 45-60ft-lbs 3°-00 12 20 27.00 25.50 27.00 3.50 3/4 x 4-1/2 14 11/4 75-90 ft-lbs 3° - 00' 12 24 31.50 30.00 31.50 3.50 3/4x5 16 11/4 75-90ft-lbs 2°-23' 10 S Mechanical Joint Assembly Clean the socket and the plain end. Lubrication is recommended for proper assembly of all mechanical joints. Lubrication and additional cleaning should be provided by brushing both the gasket and plain end with soapy water or pipe lubricant just prior to slipping the gasket onto the plain end for joint assembly. Place the gla~do t n the plain end with the lip extension to e plain endfollowed by the gasket with therrow edge of the gasket toward the plain end. Insert the pipe into the socket and press the gas- ket firmly and evenly into the gasket rec. Keep the joint straight during assembly. Push the gland toward the socket and center it around the pipe with the gland tip against the gasket. Insert bolts and hand-tighten the nuts. Make deflection after joint assembly but before tightening the bolts. Tighten the bolts to the normal range of bolt torque as indicated in the adjacent table while maintaining approximately the same distance between the gland and the face of the flange at all points around the socket. This can be accom- plished by partially tightening the bottom bolt first, then the top bolt, next the bolts at either side, finally the remaining bolts. Repeat the process until all bolts are within the approximate range of torque. In large (30"- 48") sizes, five or more repetitions may be required. The use of a torque wrench will facilitate this procedure. Installation Tips for Mechanical Joint Pipe Lubrication This is very important with mechanical joints (pipe and fittings) to ensure a leak-free assembly. Once the gasket is placed over the plain end of the pipe and prior to assembly, the gasket must be lubricated. This step is sometimes omitted because the mechanical joint appears to assem- ble easily without lubricant. After tightening of the bolts with no gasket lubrication, the gasket will tend to slowly flow into place with time, resulting in loosening of the bolts from their proper torque. This happens because the gasket has not properly seated due to friction from lack of lubrication. The lubricant allows the gasket to easily and fully "flow" into the wedge shaped gasket seat under compression from the gland during the initial assembly. When the bolts are then properly tightened, the gasket will be fully seated in the proper position and the bolts will remain tight. Joint Deflection Mechanical joint pipe should be assembled with little or no deflection of the joint. Following assembly, the joint can be deflected as necary. If the joint is assembled in the deflected condi- tion, the gasket may not be evenly seated and can also be damaged during assembly. Restraint A common misconception is that mechanical joint pipe are sometimes thought to be restrained joint pipe because bolts and nuts are involved in their installation. However, the mechanical joint does not provide any restraint. The mechanical joint can only be properly restrained by using it in conjunction with a restraining type connection such as a Griffin BOLT-LOK or MECH-LOK assembly, or with restraining glands. 0 Griffin Pipe Products Co. Mechanical Joint Pipe Pressure & Special Thickness Classes 350 51 0.25 8.9 171 9.5 52 0.28 9.9 189 10.5 3 ___________ 53 0.31 396 10.9 207 11.5 54 0.34 11.8 224 12.4 55 0.37 12.8 242 13.4 56 0.40 13.7 258 14.3 350 0.25 10.9 211 11.7 51 0.26 11.3 218 12.1 52 0.29 12.6 241 13.4 4 ___________ 53 0.32 480 13.8 263 14.6 54 0.35 15.0 284 15.8 55 0.38 16.1 304 16.9 56 0.41 17.3 326 18.1 350 50 0.25 16.0 309 17.2 341 17.1 51 0.28 17.8 342 19.0 377 18.9 6 ___________ 52 0.31 690 19.6 374 20.8 413 20.7 53 0.34 21.4 406 22.6 449 22.5 54 0.37 23.2 439 24.4 485 24.2 55 0.40 25.0 471 26.2 521 26.1 56 0.43 26.7 502 27.9 555 27.8 350 0.25 21.1 408 22.7 451 22.6 50 0.27 22.8 439 24.4 485 24.3 51 0.30 25.2 482 26.8 533 26.7 8 _____________ 52 0.33 905 27.7 527 29.3 583 29.2 53 0.36 30.1 570 31.7 631 31.6 54 0.39 32.5 614 34.1 679 34.0 55 0.42 34.8 655 36.4 725 36.3 56 0.45 37.2 698 38.8 773 38.7 350 0.26 27.1 524 29.1 578 28.9 50 0.29 30.1 578 32.1 638 31.9 51 0.32 33.2 634 35.2 700 35.0 10 ____________ 52 0.35 11.10 36.2 688 38.2 760 38.0 53 0.38 39.2 742 41.2 820 41.0 54 0.41 42.1 794 44.1 878 43.9 55 0.44 45.1 848 47.1 938 46.9 56 0.47 48.0 900 50.0 996 49.8 350 0.28 34.8 672 37.3 741 37.1 50 0.31 38.4 736 40.9 813 40.7 51 0.34 42.0 801 44.5 885 44.3 12 ____________ 52 0.37 13.20 45.6 866 48.1 957 47.8 53 0.40 49.2 931 51.7 1029 51.5 54 0.43 52.8 996 55.3 1101 55.1 55 0.46 56.3 1059 58.8 1171 58.6 56 0.49 59.9 1123 62.4 1243 62.2 Standard Dimensions and Weights per ANSI/AWWA C 151 ** Average weight per foot" shown in tables includes the weight of the bell Pressure & Special Thickness Classes (continued) 250 0.28 40.4 798 44.3 879 48.8 300 0.30 43.3 850 47.2 937 46.9 350 0.31 44.7 875 48.6 965 48.3 ____________ 14 50 0.33 15.30 47.5 926 51.4 1021 51.0 51 0.36 51.7 1001 55.6 1105 55.3 ____________ 52 0.39 ____ 1077 59.8 1189 59.5 53 0.42 60.1 1153 64.0 1273 63.7 54 0,45 64.2 1226 68.1 1355 67.8 55 0.48 68.4 1302 72.3 1439 72.0 56 0.51 72.5 1376 76.4 1521 76.0 250 0.30 49.3 973 54.0 1071 53.6 300 0.32 52.5 1030 57.2 1135 56.8 350 50 0.34 55.8 1090 60.6 1201 60.1 51 0.37 60.6 1176 65.3 1297 64.9 16 ___________ 52 0.40 17.40 65.4 1263 70.2 1393 69.7 53 0.43 70.1 1347 74.8 1487 74.3 S 54 0.46 74.9 1434 79.7 1583 79.2 55 0.49 79.7 1520 84.4 1679 84.0 56 0.52 84.4 1605 89.2 1773 88.7 250 0.31 57.2 1129 62.7 1243 62.1 300 0.34 62.6 1226 68.1 1351 67.6 350 0.36 66.2 1291 71.1 1423 71.2 50 0.35 64.4 1256 69.8 1387 69.4 51 0.38 69.8 1356 75.3 1495 74.8 18 ____________ 52 0.41 19.50 75.2 1453 80.7 1603 80.2 53 0.44 80.6 1550 86.1 1711 85.6 54 0.47 86.0 1647 91.5 1819 91.0 55 0.50 91.3 1743 96.8 1925 96.3 56 0.53 96.7 1840 102.2 2033 101.7 250 0.33 67.5 1328 73.8 1463 73.1 300 50 0.36 73.5 1436 79.7 1583 79.2 350 0.38 77.5 1508 83.8 1663 83.1 51 0.39 79.5 1544 85.8 1703 85.2 20 ____________ 52 0.42 21.60 85.5 1652 91.8 1823 91.2 53 0.45 91.5 1760 97.7 1943 97.2 54 0.48 97.5 1868 103.7 2063 103.2 55 0.51 103.4 1974 109.7 2181 109.1 56 0.54 109.3 2081 115.6 2299 115.0 200 0.33 80.8 1597 88.7 1758 87.9 250 0.37 90.5 1771 98.4 1952 97.6 300 0.40 97.7 1901 105.6 2096 104.8 350 0.43 104.9 2031 112.8 2240 112.0 50 0.38 92.9 1815 100.8 2000 100.0 24 51 0.41 25.80 100.1 1944 108.0 2144 107.2 S 52 0.44 107.3 2074 115.2 2288 114.4 53 0.47 114.4 2202 122.3 2430 121.5 54 0.50 121.6 2331 129.5 2574 128.7 55 0.53 128.8 2461 136.7 2716 135.8 56 0.56 135.9 2589 143.8 2860 143.0 Standard Dimensions and Weights per ANSI/AWWA C 151 ** "Average weight per foot" shown in tables includes the weight of the bell Indicator Posts Fire Protection • Upright Posts.For use with non-rising stem indicator post style gate valves UL LISTED • FM APPROVED MATERIAL LIST PART SPECIFICATION Locking Wrench Cast Iron ASTM A126 Class B Operating Nut Bronze ASTM A584 Alloy 83600 Retainer Ring Nitrile Upper Body Cast Iron ASTM Al 26 Class B 5, Window Lexan-UV Stabilized 'Open' Target Cast Aluminum Shut' Target Cast Aluminum Pipe Plug 1/2" NPT Steel - Zinc Plated Eye Bolt Steel Operating Rod H.R. Steel ANSI M1020 Target Carrier Nut Bronze ASTM B854 Alloy 83600 12, Target Carrier Plate Steel Target Retainer Clamp Stainless Steel Type 302 Hex Nut Steel - Zinc Plated Pan Head Screw Steel - Zinc Plated Hex Head Screw Steel - Zinc Plated Spacer Sleeve Ductile Iron Body - Outer Ductile Iron Body - Inner Ductile Iron Hex Head Screw Steel - Zinc Plated 21, Operator Rod Coupling Cast Iron ASTM A126 Class B Cotter Pin Brass Hex Head Screw Steel - Zinc Plated 24, Base Flange Cast Iron ASTM A126 Class B Hex Head Screw Steel - Zinc Plated Hex Nut Steel - Zinc Plated NIBCO Fig. No. NIP-1AJ Mated to NIBCO IBBM Gate Valves Bury Depth Dimensions (Inches - Rounded)* S NIP-i AJ Upright Post Holes .75 drill On 10½" bolt circle. Diameter drilled on center. Mm. Bury Depth Max. Bury Depth Valve Size** NIP-1AJ NIP-1AJE NIP-1AJEE NIP-1AJ NIP-1AJE NIP-1AJEE 4" 33" 51' 59" 52" 70' 88" 6' 40" 58" 76" 59" 77' 95" 8" 43" 61" 79" 62" 80" 98" 10" 48" 66" 84" 67" 85" 103" 12" 52" 70" 88" 71" 89" 107" Note:Add 18' Bury Depth for NIP-1AJE Add 36" Bury Depth for NIP-1AJEE Special lengths available in 6" increments, P.O.A: beyond NIP-1AJEE Indicator Post Gate Valve Dimensions 4" 6" 8" 10" 12" Valve Size In. mm. In. mm- In. mm. In. mm In. mm. Dimension from centerline of F/M609 llBBMl 14.1 358 18.6 472 22.1 561 25.8 655 29.5 749 valve to top of F/M609RW the _operating _nut 13.5 342 17.0 432 20.5 520 23.8 605 27.0 686 Turns to open F/M609 (IBBM) -(+.5 turn) F/M609RW 9 13.5 17.5 30.25 38.25 1 12.8 1 15 17.6 21.2 25.1 ®LISTED jc APPROVED NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.2953455 C 250 PSI WWP Iron Body Gate Valves Fire Protection Valve • Bolted Bonnet • Indicator Post Pattern • Non-Rising Stem • Resilient Wedge Epoxy Coated Interior/Exterior • Drilled, Tapped and Plugged at Boss Location A** 250 PSI/17.2 Bar Non-Shock Cold Working Pressure (1600 F/il0 C max. operating temperature) UL/ULC LISTED • FM APPROVED • AWWA C-509 & 515 ' NEW YORK CITY M.E.A. APPROVED 236-93E • CERTIFIED LEAD-FREE* BY IAPMO R&T TO NSF/ANSI 372 MATERIAL LIST PART SPECIFICATION I LCW.t.EAD 1. Valve Body Ductile Iron ASTM A536 2 Resilient Wedge Ductile Iron ASTM A536/EPDM ASTM D2000 Wedge Nut Bronze ASTM B584 UNS C83600 Stem Bronze ASTM B150 UNJS C61400 Bonnet Gasket EPDM ASTM D2000 Bonnet Screw (F) Alloy Steel ASTM A574M Zinc Plated (M) 18-8 Stainless Steel ASTM 193 Bonnet Ductile Iron ASTM A536 M-609-RW Mechanical F-609-RW Flanged Stem Primary 0-Ring EPDM ASTM D2000 Stem Thrust Washer (lower) Bronze ASTM B584 UNS C83600 Stem Thrust Washer (upper) Stainless Steel ASTM A276 UNS S41000 Gland _Seal _0-Ring EPDM _ASTM _02000 Stem Seal Bushing Bronze ASTM 8584 UNS C83600 13, Stem Secondary 0-Ring EPDM ASTM 02000 Gland Flange Ductile Iron ASTM A536 Stem Ring Wiper EPDM ASTM 02000 Square Operating Nut Cast Iron ASTM A126 Class B -- Operating Nut Washer Carbon Steel Zinc Plated I Operating Nut Screw Alloy Steel ASTM A574M Zinc Plated 0' Gland Flange Screw Alloy Steel ASTM A574M Zinc Plated F-1 Indicator Flange Screw Alloy Steel ASTM A574M Zinc Plated 21, Indicator Post Flange Ductile Iron ASTM A536 22. UL/FM Label Aluminum NOTE: Body, Bonnet and lad. Post Flange coated with electrostatically applied fusion bonded epoxy resin inside and outside per AWWA C-550. Epoxy NSF and FDA certification NOTE: Flanged valve is consistent with ANSI B16.1 Class 125. Drilled, tapped and plugged at Position A with ½' valve sizes 21/2"-4", Y4" on 6-8,1" on 1F-12'. DIMENSIONS-WEIGHTS-QUANTITIES M-609-RW MJ x MJ Size In. mm. A In. mm. B In. mm. M-609-RW Dimensions C D In. mm, In, mm. In. E -m rn. In. F mm. Bolt Circle Flange Turns In. mm. Holes To Open Weight Lb s. Kg. 4 100 10.0 254 13.5 3441.00 26 9.1 232 6.0 153 3.9 100 7.50 191 4 13.0 89 40 6 150 11.5 292 17.4 441 1.06 27 11,1 283 8.1 206 5.9 150 9.50 241 6 15.7 132 50 8 200 11.5 292 20.8 529 1.12 28 13.4 340 10.3 261 7.9 200 11.75 298 6 17.3 190 86 10 250 13.0 330 24.2 614 1.18 30 15.7 400 12.3 313 9.8 250 14.00 356 8 21.4 287 130 12 300 14.0 356 27.6 700 1.25 32 18.0 456 14.4 367 11.8 300 16.25 413 8 25,3 408 185 Size In. mm. A In. mm. B Tn7 mm. F-609-RW Dimensions C D In. mm. In. mm. In. F mm. C In. mm. Bolt Circle Flange Turns In. mm. Holes To Open Weight Lbs. Kg. 4 100 9.0 229 13.5 344 0.94 24.0 9.0 229 2.13 54 2.1 54 7.50 191 8 13.0 91 41 6 150 10.5 267 17.4 441 1.00 25.4 11.0 279 2,24 57 2.5 64 9.50 241 8 15,6 142 65 8 200 11.5 292 20.8 529 1.13 28.6 13.5 343 2.48 63 2.8 70 11.75 298 8 17.3 216 98 10 250 13.0 330 24.2 614 119 30.2 16.0 406 256 65 2.8 70 14.25 362 12 21.4 314 143 12 300 14.0 356 27.6 700 1.25 31.8 19.0 483 2.91 74 3.4 86 17.00 432 12 25.3 446 203 FM FREEZING WEATHER PRECAUTION: Subsequent to testing Lead Free refers to the wetted surface of pipe, fittings and fixtures in potable water a piping system, gate valve should be in an open position systems that have a weighted average lead content !~ 0.25% per the Safe Drinking C&LISTED APPROVED to allow complete drainage. Water Act (Sec. 14171 amended 1-4-2011 and other equivalent state regulations D . NIBCQ INC. WORLD HEADQUARTERS • 1516 MIDDLEBIJRY ST. • ELKHART. IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1888.3364226 • INTERNATIONAL OFFICE PH: +1574.29S.3327 • FAX: +1.574.295.3455 FireLock® Butterfly Valve F5EUIHAT ION Sh(.TION 2.4.0 c®vs ILPCBI 0026 See Victaulic publication 10.01 for details S SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE The Series 705W butterfly valve features an approved weatherproof actuator housing approved for indoor or outdoor use. It has a ductile iron body and disc with EPDM disc coating. The body is coated with a heat fused polyphenylene sulfide blend to meet FM requirements. Designed for fire protection services only, Series 705W valve is UL Listed and FM Approved for 300 psi/2065kPa service. Contact Victaulic for details of agency approvals. WEATHERPROOF ACTUATOR Supervisory switches that monitor the valve in the fully open or fully closed position for valves are available 2 1/2 - 12/65 -300mm pre-wired (PW). OPTIONAL SUPPLY-SIDE TAP Series 705W valves are available with a ½' (for 2 ½', 76.1 mm and 3" sizes) or 1/4' (4 12/100-300 mm sizes) NPT supply side tap designed to allow direct water supply connection to Victaulic FireLock actuated fire protection valves. See separate drawings below. This is an optional feature and must be clearly noted on all orders. ¼" tap avail- able by special order. Contact Victaulic for additional information on tapped valves. MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536, coated with polyphenylene sulfide blend. Disc: Ductile iron conforming to ASTM A-536, various grades, EPDM coated. S Disc Coating: Grade "E" EPDM EPDM (Green color code). Temperature range -30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Stem Bearings: Teflon impregnated fiberglass with stainless steel backing. Stem Bearing Nuts: Type 416 Stainless Steel. Tap Plug: Carbon steel, plated. 0-Ring: EPDM Bracket: Carbon steel, painted. Actuator: 2½ - 8/65 - 200 mm: Bronze traveling nut on a steel lead screw, in a ductile iron housing. 10 - 12/250 -300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing. . JOB/OWNER System No. Location CONTRACTOR ENGINEER Submitted By . Spec Sect Para__________ Date Approved Date www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. Oc 2006 VICTAULIC COMPANY, ALL RIGHTS RESERVED. PRINTED IN THE USA. ocit V _'~ Ai-c—ta—ulic~ 1^110 1 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES SPECIFICATION SECTION 2.4.D jlj• its FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE I MATERIAL SPECIFICATIONS Handwheel: 21/2 -4 3.0 12 65 - 100 76.2 5-6 45 200 125 150 114.3 200 160mm 250 10--12 9 25030O 225 VdS version not UL Listed, FM Approved or LPCB Approved www.victauIic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.. lrtlo x.04-ist-a-UI& oclif r 0 U R.W1 )L%j I I)UlI 4PL) IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE DIMENSIONS - C®S j ILPCBl Size Dimensions — inc hes/mil Ii meters Each IT 2½ 2.875 3,77 8,76 4.21 606 300 000 u/5 8 65 730 956 2x25 - 1069 1544 762 00 91 38 3,000 377 1 876 421 608 400 000w 075 83 76.1 mm 751 456 2225 - 069 i1544 752 00 191 38 3 3.500 377 940 008 421 1 608 300 000 075 89 80 389 956 2348 20 1069 1 1544 752 00 191 40 4 4500 463 1084 001 601 698 300 073 113 149 100 1143 117o 8753 18 1527 1773 762 185 287 68 5.500 588 1238 0.43 601 85/ 450 - 210 P97mm • 1397 1494 3145 109 527 2177 1143 - 95 5 5563 588 1238 043 601 8.517 450 210 125 113 1494 3145 109 527 2177 1143 - - 95 6500 588 1341 100 751 932 450 160 188 255 1651 mm 1651 1494 3406 254 1908 1 2367 1143 1 405 478 120 6 6,625 588 1341 100 751 1 932 450 '60 188 255 150 1683 1444 3406 254 1408 2367 1143 405 474 120 8 8.625 533 1550 127 965 1098 630 000k 068 430 200 2191 - 1354 4191 323 2451 2789 1600 1 00 173 195 10 10,;50 640 '°14 172 1220 16.19 900 800 250 2730 1626 4262 437 3099 4112 2286 - - 363 12 12/50 650 7154 766 1425 1/27 900 1020 300 3239 1651 547.1 676 3620 4374 2286 - - 63 On Centerline These dimensions apply only to a Series 705W Butterfly Valve with a ½-inch NPT, supply-side tap 1.10 prevent rotation of valves. it is recommended that Series 705W be installed with Victaulic Style 07 Zero-Flex®, Style 005 FireLock, Style 009/009V FireLock EZ, or Style HP-70 Rigid Couplings, lfVictaulic flexible couplings are used. additional support may be required. Valve must not be installed with disc in full open position. Disc must be partly closed so that no part is protruding beyond end of valve body. Victaulic grooved end butterfly valves are permitted for use with grooved end pipe (IFS) only. Not permitted for use with plain end (IFS) pipe. Series 705W valves are designed for ambient weather conditions as opposed to submersible service. L/\ L A1 I L] 5 - 12-INCH/125 — 300 MM SIZES 21h - 4-INCH/65 - 100-MM SIZES wwwvictaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. nr, r X. 1htauiic 1^ 10 • IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES I i'jt'j t IUI\I 'u I U Id FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE I PERFORMANCE The chart expresses the frictional resistance of Victaulic Series 705W in equivalent feet/meters of straight pipe. 2½ 2875 1 5 mm 6.500 . 65 730 16 1651 25 76 3,000 5 6 6.625 S 1mm 761 16 150 1688.3 25 3 3500 5 8 8625 11 80 89 16 200 2191 34 4 400 12 10 10,750 12 100 1143 3.7 250 - 2730 37 1397 mm 5.500 12 12 12/53 14 139 .7 37 300 3239 4.3 5 5.563 12 125 141.3 3.7 www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. Ai _r_ 1f 10 C IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES SPECIFICATION SECTION 2,4.D W. .1 Its FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE PERFORMANCE C, values for flow of water at +60°F/+16°C with a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for CV Values: AID = Q2 Where: Q = Flow (GPM) v AP = Pressure Drop (psi) Q = C x C= Flow Coefficient Formulas for Kv Values: AP = Q, Where: 3\ K Q= Flow I Im ) Q = K AP Pressure (bar) K = Flow Factor www.victaulic.com \,#t9uliC VICTAULIC IS REGISTERED TRADEMARK or vcruuc COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.. In 10 C DEW r I IPS CARBON STEEL PIPE FIRE PROTECTION VALVES LU. Its FireLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE SWITCH AND WIRING 1. The supervisory switch contains two, single pole, double throw, pre-wired switches. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps © 250 VDC Switches supervise the valve in the "open" position. One switch has two #18 MTW wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 MTW wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. A #14 MTW ground lead (green) is provided. Switch #1 = Si For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Si Normally Closed: (2) Blue Common: (2) Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe ME A CCM TO E10-OF I\E RE515TW. 19 EL OR N17ILTOP C-NTACTRM N(, EWSNY NC N 11 -J-EIIIIIII< Swftch N 2 kd per teroNnel Swild, 2 1 Iced plwnend NOTE: The above diagram shows a connection between the common terminal (yellow - Si and yellow-with-orange stripe - S2) and the normally closed terminal (blue - Si and blue-with-orange stripe - S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). www.victaulic.com . - - VICTAULIC IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. tauI ii c nn, r 121 10 FireLock® Check Valves SERIES 717 ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Series 717 FireLock check valve is a CAD-developed design that is hydrodynamically efficient. A totally rubber encapsulated disc on 4— 12/100-300 mm sizes provides superior corrosion resistance. This single disc design incorporates a spring assisted feature for non-slamming operation. For systems requiring a Riser Check option refer to section 10.09. The 47100 mm and larger sizes are provided with upstream and downstream drains and a welded-in nickel seat design. All sizes of Series 717 can be installed in the vertical or horizontal position to provide leak-free sealing under conditions as low as five feet of head. Each valve is factory tested to 500 psi/3440kPa. The 21/2 and 3/65 and 80mm sizes are UL/ ULC Listed and 47100mm sizes and larger are UL/ULC Listed and FM Approved for services up to 250 psi/1725 kPa. Sizes 4-8/100-200 mm (except 165.1 mm size) are VdS approved. Grooved ends allow fast, easy installation with just two Victaulic couplings or the valve may be mounted to flanged (ANSI CL.150) equipment using either to Victaulic Style 741 Vic-Flange or Style 744 FireLock flange adapters on either end. DIMENSIONS — A—h 4- B —I TYPICAL 2½ — 3/65 — 80 MM FR' A I ODE t/ NPT Upstream Drain (2) /7 NPT Downstream Drain 0 2' NPT (Drain Optional) TYPICAL 4-8/100-200 MM pi 0½' NPT upstream Drain 0½' NPT Downstream Drain TYPICAL 10- 12(250-300 MM 1" Dimensions- Inches/millimeters 7) OLL2_ _iL - 2.875 285 426 35/ 36 730 99 108 Ri - - - - - 16 3.000 188 4.26 3.57 3 761 mm 76199 103 91 ' - - - - - 1.6 3,500 425 5.06 417 i 45 80 889 108 129 106 - - - - - - 20 4t 4,500 963 600 388 273 350 200 450 350 335 200 100 1143 245 152 99 70 1 89 51 1 114 89 85 91 St 5.563 1050 680 450 417 215 1 588 408 398 270 1413 267 173 114 - 106 55 149 104 101 123 5500 1050 680 450 417 215 588 408 398 270 139.7 f 1397 267 173 114 - 106 55 149 104 101 123 o 6.625 1150 800 500 450 738 667 473 389 380 150 1683 292 203 127 iia 61 169 120 99 172 6500 1150 800 500 450 238 5.67 473 389 380 165A mm 165 292 203 127 1 114 61 169 120 09 172 8t 8.625 1 1400 988 606 505 565 215 885 565 575 640 00 2191 356 251 154 128 144 55 225 144 1 146 290 10 10/50 : iuo 1200 /00 596 669 215 1 1092 673 1000 250 2730 1 432 305 180 151 170 55 277 171 - 454 12 12.750 1950 1400 806 691 764 251 1281 773 1400 300 3239 ' 495 356 205 176 194 64 925 196 - 63.5 t VdS Approved . JOB/OWNER System No. Location CONTRACTOR Submitted By Date ENGINEER Spec Sect Approved Date MV WWW.VICTAULIC.COM VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 162007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. Ai -C —ta _U1 ii C r ocit I.' 1frio 1 IPS CARBON STEEL PIPE FIRE PROTECTION VALVES SPECIFICATION SECTION 24.E jIJtJ FireLock® Check Valves SERIES 717 MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. 2½ - 3/65 - 80mm sizes PPS coated. 4— 12/100-300 mm sizes painted black enamel. Body Seat: 2½ - 3/65 - 80mm sizes PPS coated. 4— 12/100-300 mm integrally welded on nickel alloy. Disc Seal or Coating: Grade "E" EPDM EPDM (Green color code). Temperature range —30F to +230°F/-34°C to +110CC. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for.a listing of services which are not recommended. Discs: 21/2 - 3/65 - 80mm Aluminum bronze conforming to ASTM B-148 with Grade "E" Seal. 4 - 12/100-300 mm ductile iron conforming to ASTM A-536, grade 65-45-12, fully encapsulated in Grade 'E" elastomer. Shaft: 21/2 - 3/65 —80mm Type 416 stainless steel. 4 - 12/100 - 300mm Type 316 stainless steel. Spring: All sizes Type 302/304 stainless steel. Shaft Plug: 2 1/2 - 3/65 - 80mm only; SAE Hex Socket Type conforming to ASTM A-576, cadmium plated to military specifications QQ-P-416A, class 3 typo 2. 4— 12/100-300 mm only; carbon steel zinc plated to ASTM B-633. Pipe Plug: 4— 12/100-300 mm only; carbon steel zinc plated to ASTM B-633. www.victaulic.com vicrAuLic IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA, in no JtauIic or, 11. KW-900-W Wafer Style Body Style 2112 - 12 (excluding 5" & 6) KW-900-W Wafer Style Body Style 5, 6, 14 & 16 O 250 PSI WWP Iron Body Check Valves Fire Protection Valve • UL listed FM Approved Double-Door • Wafer Style • Rubber Seat • Spring Actuated ULIULC LISTED • FM APPROVED* MATERIAL LIST PART SPECIFICATION Body Ductile lion ASTM A536, Grade 65-45-12 - 2 thru 12 14 thru 16 Cast Iron ASTM 126, Class B WI Buna-N (Nitrile) resilient seat molded to body Disc Bronze ASTM B584 Alloy C83600 Torsion Spring Stainless Steel Hinge Pin Stainless Steel Stop Pin Stainless Steel Thrust Bearing Stainless Steel Hinge Pin Retainer Steel Stop Pin Retainer Steel Stabilization Sphere Buna-N Spacer High Density Polyethylene C NOTE: 2'/2" - 12" UL Listed to 250 psi 4", 6', 8", 10" and 12" ULC listed to 250 psi 14" & 16" FM Approved QniY to 200 psi KW-900-W Wafer MINIMUM amp ON ItANOC I!] DIMENSIONS-WEIGHTS-QUANTITIES Size In. mm. A In. mm. In. B mm. Dimensions C In. mm. D In. mm. E In. mm. CN Weight Lbs. Kg. 2½ 65 2.38 60 SOD 152 .125 3 3.50 89 1,313 33 108 4.3 1,95 3 80 2.63 67 5.63 143 .188 5 3.875 98 1.688 43 178 6.1 2.77 4 100 2.63 67 7.75 197 .625 16 4.75 121 3.063 78 440 8.8 3.99 5 125 3.25 83 7.56 192 .813 21 5.50 140 3.625 92 560 13.0 5.90 6 150 3.15 95 8.63 219 .813 21 6.25 159 4.250 108 840 18.0 8.16 8 200 5.00 127 12.25 311 1.000 25 8.00 203 5.500 140 1600 37.0 16.78 10 250 5.50 140 14.75 375 2.125 54 10.12 257 8.500 216 2700 65.0 29.48 12300 7.13 181 17.38 441 1,938 49 12.00 305 9.250 235 4700 94.0 42.64 14 350 7.25 184 11.75 451 3.250 83 - - 13.000 330 5200 200.0 90.75 16 400 7.50 191 20.25 514 4.500 114 - - 15.000 381 7200 285.0 129.28 'Note: 14" and 16" sizes, 200 PSI WWP, FM approved only. Features Spring loaded for fast closure, eliminating reverse flow slam and water hammer Easily installed, with gasket, between standard class 125 flanges. Only one set of flange studs is needed. May be installed in both horizontal and vertical lines with upward flow. C®US LISTED <@> APPROVED NOTE: Twin Disc Check Valves can be installed horizontally or in the vertical position with flow up. CAUTION: For horizontal flow applications, the valve must be installed with disc hinge pin in the vertical position to insure proper operation. WARNING: These are not to be used as steam valves Valves are not to be used near a reciprocating air compressor Install 5 pipe diameters minimum downstream from pump discharge or elbows to avoid flow turbulence. Flow straighteners may be required in extreme cases. NOTE: On pump discharge, the preferred check valves are in-line spring loaded, NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART. IN 46516-4740 • USA • PH: 1.600.234.0227 TECH SERVICES PH; 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX; +1.574.295.3455 Piping (by others) BOTTOM VIEW SPECIFICATION SECTION 2.6.A LOS ANGELES AREA (800) 366-3473 POTTER NEW YORK AREA (800) 526-4592 CHICAGO AREA (800) 547-3473 ZROEMER ATLANTA AREA (800) 762-0542 Call Potter Roemer for current listings and approvals RREPR07EC77ONEQUIPME1IT MIAMI AREA (866) 961-3473 Dimensions are subject to manufacturer's tolerances, DALLAS AREA (866) 664-3473 and change without notice. We assume no responsi- _______________________________________________________________ bility for use of superseded or void data. EXPOSED FIRE DEPT. INLET CONNECTION APPROVED F TWO-WAY WITH SINGLE CLAPPER %2-1 5710—A—DI tPTx NST REGULARLY ID FURNISHED: Model Ductile iron two-way inlet (sold sep body painted red, swing clapper ..-" and brass pin lug swivel. ...- Lettering: AUTO. SPKR. Pressure Rating: 300 (2,067 kPA) Compliance: ULJfed, FM Approved Special ThadAvaiIable Thread: 4" Female NPT Threads 45o 2-1/2 Female Threads (Brass Swivel) TOP VIEW LJ Model 5715-A-Dl Angle Outlet 4x2-1/2 NPTx NST FRONT VIEW Shown with ID Plate I Model 5962 (sold separately) t 0-1 2-1/2" Female NST REGULARLY Threads FURNISHED: (Brass Swivel) Ductile iron two-way inlet body painted red, swing clapper and brass pin lug swivel. Lettering: AUTO. SPKR. Pressure Rating: 300 psi (2,067 kPA) umeam Compliance: UL Listed, FM Approved p Special Thread Available Pi ing SIDE VIEW 4" Female (by others) Specify Thread: NPT Threads fj\ Revised Reviewed MEMBER OF A1104, tt1ONA&. 6/23/08 6/23/08 ASGOCUMM. W_ I MODEL NUMBER • S SPECIFICATION SECTION 2.7.A Fi relock® 0 utIetT SEE VICTAULIC PUBLICATION 1001 FOR DETAILS STYLE 922 The Style 922 OuUei-T provid a convenient mall of iriorórating ½, , and 1715, 20 and 2t mm outlets for directly connectin spnrlklf r, drop nipples, sprIgs, gauges drains and other outlet products Available for fl through 76] mm/32 to 76.1 mm piping systems Style 922outlets ate UL/ULC Listed, LPC, Vds/fM dppiuved fuj boinch cunrctiunsutc Wet and dry syslerns The locating collar engages Into the hole prepared in the pipe When tightened, the assenibty compresses the gasket onto The OD of the pipe The Style 922 Outlet T is tJIJFM rated up to 300psl12O68kPa and VCJS rated up to 16 bar at the ambient temperatures typical for fire piotection systems. Style 922-Is sultoble for use on standard,, lightwafl, Schedule 5aM other specialty pipes.* It is supplied with a clear, rust Inhibitive coating, Contact Victaulic (or other optional coatings CosuIt Section 10.01 for spezlkis tiris/appovaIs. MATERIAL SPECIFICATIONS Housing: Duci Ile hen conformitip, to ASIM A3e: grade 6155-45,-121 Dtktiki 400 conforming to ASIM A-395, tirade 65-45-15, is available upon Speca1requesL Gasket: . Grad E'EPDM - TypeA (Violet oir code) Firebck products have been Listed by Uflderwnters Laboratories Inc and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated workIri ptessws using the Grade E' Type A Gasket System. Bolts/Nuts Heat treated plated carbon steel trackhead meeting the physical and chemical require merits of ASTM A 449 and physical requirements of AST A-183. 305/OWNER CONTRACTOR ENGINEER System No. Submitted 8y Spec Sect Pare_________ Location Date Approved Date_________________________________ Www.victaullc.com - ViCTAULIC IS A RGISTEREQTRADEMARK OFVICTAUUC COMPANY.0 200SViCTAIJLIC COMPANy, ALL RIGHTS RESERVED. PRINTED1ThE USX CtUc' DCU fl 1V' I DIMENSIONS IPS CARBON STEEL PIPE HOLE CUT PRODUCTS SI-'ELIbIUA I ION SIU I ION 2.1.A 1u. FireLock® Outlet-T SEE VCTAULtC PUBLICATION 10.01 FOR DETAILS STYLE 922 Numm.,,l Size Hole Appox. - LI 1 •:.•'ir o 155 ½ X Imb 130 33.0 1133 455 j 130 249 5 S3_JjJ 255 30 OAS 20 12.5 S 45,5 2339 S 9&3 65.0 030 30.2 152 215 1.10 3.67 2.66 1.2 75 3022 38.&i 2 554 77 S3 5.O 054 5 2156 '30 5 3022 663 420 30 oso 650 004 131. 1.40 1.95 1.22 408 236 12 20 30.2 36 5 V 0 1015 65D 0.54 2,12 2.58 3 30.2 457 239 340 103.6 652) 059 x 16 144 166 46 4.60 2.56 1 13 5 15 30.2 42.2 555 371 116.8 CW I 030 '30. 554 219 '-5 350 256 .4 20 5502 41.7 55.6 341 1028 650 0.30 T 14à 588 254 146 5O -236 15 is 3022 47.6 r3 I II63 6W om A 4 191 1 17 i1r So 55 . X 4&5 .ji3 4 13/i 6) 073 589 2.44 573 5240 2.56 it Xl 30.2 .46.0 6355 4339 1372- 63.0 2.13 279 171 5.40 255 10 25 502 54.1 70.9 434 liT 414 1341 650 Q.73 76.1 14 U 15 3012 591 485 2.44 62.0 530 1559.7 25.6 1 133 622) 0,73 1 12 244 1'1 52 255 1,c 5553 550 520 444 1394 650 0,73 1'M 23 2.79 111 206 '1 .7 5250 25. 30.2 54.1 70.9 1 414 1 1397: 1 65.0 0.60 1 Viotoutf fernas thrded products are designed toaccor mothle standard 1'WT or BSPT (opIonai) malp pipe thread only. Use of main threi hd products with spe featurr such as probes dry pen dent sprinklers etc, should be verified as suitable for use with this Vlctaul1 product Failure to venfy suitability in advance may, result In assernby problems or leakago. 'C rror of run tengated pipe end for NPTthra is u rnensions a re dpIo3i rrte 1~ www.vlctaulic.com VICTAUUC 1$ A R ISTR1Q TRADEW or V(TAUUC COM PAN Y 0 ZX6 yb so COMPANY RID}IT$ rtcscRvEo PRINTED IN 3 1... Sk An'ta-uha or,, In 0 ® .e J ILPCBI SEE VIcTAULIC PUBLICA ION 10.01 FOR DETAILS STYLES 920 AND 920N STYLE 920 CROSS PA1'ENTEO I L_'.dII I',J.' I I',JIM JL.I.d I I.JII (,.l .P'. iMI1ruIoII1mr STYLES 920 AND 920N VictaUlic MeChanical-TO Outlet preddes a direct branch connection at any IeatLon a hole can be cut In pipe The hole is cut oversize to receive a °hol Iwder Ic .ting collar which secures the outlet in positiOn permanently. A pressUte responsive gasket seats on the pipe 0,0. Cross type connections can be achieved by utilizing two Upper housings of the same style and size with the same or differing branch sizp connections NOTE tylc 920 and Style 920N housings cannot be mated te each othec to achieve a cross connection. Style 920 and Style 920N Mechanical T ot.illets are available with grooved or female threaded outlet Specify chowe on order. Units are supplied painted with plated bolts Galvanized hous Ings are available supplied With plated bolts All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be Installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap 110 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical.T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap [I Mechanical-I unit. See page 8 for further information. 0 I--- - - MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request, Optional: Hot dipped galvanized Gasket: (Specify cholce*) Grade "E" EPDM EPOM (Green color code). Temperature range —30°F to +2306F/-34°C to +110C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services, UL Classified in accordance with ANSI/NSF 61 for cold i86F/+3OGC and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES, Grade "T" nitrile Nitrite (Orange color code). Temperature range .20*F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the pcifled tPirrippmfivo ring. Not rcommnded for hot water services, over e-1Fk660C or for hot dry air over +140°Ff+60°C. *Services listed are General Service Recommendations only. it should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket. service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. . JOB/OWNER System No. Location CONTRACTOR ENGINEER Submitted By Spec Sect Date Approved Para Date www.vlctaullc.com V1cTAUUC IS REGISTERED TRADEMARK 0FVICTAUUC COMPANY. 02C0I VICTAUUC COMPANY ALL RIGHTS RESERVED PRINTEDIN THE USA l3il I /ctaulic 1-tn, I IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 1 L.0 STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides .a direct branch cOnnection at any location where a hate can be cut In the pipe A pressUre responsive gasket provides the Seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe, also available for use with HDPE pipe Sizes from 2 x, W150 x 15 mm through 8x 47200 x 100mm IMPORTANT NOTES: Stylt 920 and $ty492014 housIngs cannothe. mated to one another to achieve cross connections. .IVI ti, Pressure IJIItILICSflL -Weight Each 0.1 1 U I1 IJ3 IL'L 0 L.L Iii fl4 144 '37 500 .50 2.00 .9 161 '5 VS 3.11 I * 4 740 ' ., '..'. -IS 1.97 233 1.61 :535 2.75 3,1 45 () 500 1.50 20 3450 383 5 64 41 136 70 1.5 500 15 1.85 253 - 161 535 275 30 - 25 4450 38. '84- 47 - 41 138 70 1.4 IV, (035 92OKI 500 175 295-275 3.00 1.61 135 3.20 35 32 32 3A50 44,5 _52 70 "6 41 136 76 17 15 175 2.03 275 31 161 5'5 38 32 155(a), , 310 4c,s"O 44.5 $2 70 i 41 i>. 83 17 15 7½ .55 (a) X 201'l 500 1.50 2,2) 2.74 91.82 5.64 2.75 3.0 15 3450 383 56 70 46 143 70' 1.4 (a) caN 501) ISO 218 2.74 1.82 464 775 3.0 4450 581 544 701 46 141 70 1.4 - 1(a) 9201! 5('5) 130. 2.06 i 274 122 464 2,75 29 25 3450- 38.1 52: 10 - 46 143 70 1.4 1551 (a) 500 175 230 300 3.25 1.82 6.29 3.51) 35 3.2 7 40 Z4C 500 L450 ' 2.00 55'S 58 2.23. 300 58 75S3 320 46 1 1.82 426 46 9 1 325 83 17 5 3,3. 1.6 36 L7 55(a) ., 3430 150 2.72 275 2.25 .6.46 318 39 IS 7705 32 56 70 - 57- 164 61 1,8 55 (a) 920 300 1.50 239 273 2.25 6.46 118 3.9 20 2065 383 56 70 - 57' 164 .51 12 - I (aS 920 366 130 2.07 2.75 2.75 6.46 3018 3.8 25 2765 381 53 70 - 57 164 8) 1.7 - a 500 175 270 3010 31 192 o20 300 35 32 32 3450 445 56 76 84. 49 160 38 1.6 15 '8 (a) 500 ,Q0 2.45 3.011) 311 1.92 579 5.15. 35 55 40 2450 502 58 75 .84 49 1(s) 23 1.6 Is 34 9211N .12 252 3555 2.28 61 '7 >' 30 5 3'. 38.1 64 78 - SB b 70 16 - 9' N .0 11) 130 2.49 305 2.28 6.15 275 3.4 20 3450 3.811 83 78 58 1 156 70 1 1.6 75 '0N 50) 3-43Q 150 383.6) 2"8 306 78 - 228 $8- 0 15 75)5 2 70 33 14 - I % (a) 4) 02 (b ' 500 3450 1.25 445 235 325 65 83. 3.56 90 228 58- 6.15 156 300 76 3.8 1.8 31 1.8 1 70 278 3..0 35 228 615 325 41 is 34512 3015 11 . 801 51) 58. 456 81 1.9 118 2(a) 500 251) 2.75 I 350 556 2.28 6751 356 491 46 50 43a 70 89 90 58 172 99 2.3 1 2.1 P0)4 500 250 1 - 37 2.44 6 '- 1 1 18 00 3450 633 9$ 2 171 92 TABLE CONTINUED ON PG. 3 O S www.vlctaulic.com V1CTAULIC IS A REGISTERED TRADEMARK or VICTAUUC COMPANY. 02007 WCTAULIC COMPANY. ALL RICO .. RESERVED PRINTEP 1)43 ,'. Amr-A-S.Ulicr -t -I r' - 1PS CARBON STEEL PIPE- HOLE CUT PRODUCTS SPECIFICATION SECTION 2.7.A I LUZ MechanicalP Bolted Branch Outlets STYLES 920 AND 920N S DIMENSIONS IN. I.. "N~1!-' SIL @ FEMALE THREADED OUTLET Provides a direct branch connection at . any location where a hole can be cut in the pipc A pressure reonswe gasket provide the seal Request PublIcation 11,03 for Mechanical-I cross assemblies o Pressure rated up to 500psi1345OkPa on Steel pe aso available for use with HOPE pipe Sizes from .'.2 x W150 x 15mm through 8 x 47200 100mm IMPORTANT NOTES: Style 920 and Style 92014 housings cannot be mated to one another to achieve cross conneclions, M.1111'', ' .:. TABLE CONTINUED FROM PAGE 2 00 920N 500 3450 1.50 .._35 O - .69 63 ..... l't 70 3.1 1.8 - I 3S.5 2 -. 37; '.7 930+ 3450 35 . - ." "C tB - v:,. r'o 16 -- -- :5 22014 500, - 33-4.00 :. c: 3450 . - 96 102 y . I s 1.9 1.8 500 2'. ." 400 40 769 ;' .25 4.2 3.9 3450 50. ' 102 102 86 ., 83 2.0 1.9 92014 500 2.5u 3,5 4.00 4.00 2.69 701 3.88 5.0 4.6 30 3450 63.5 83 102 102 68 1' 99 23 2.1 2 (8) t 920 500 2.75 2.38 4.00 4.00 2.69 734 4.63 5.3 5.0 CS 3450 699 73 102 102 68 186 114 2.6 23 500 q.9 2.75 I 4. 00 2.6.9 734 4.63 6.4 9.0 3451 - 102 5 t18 2.9 ..r '. 4.504127.89 ,164 920 , -. 04 105 U.'- 8 1 29 ou 7 60 67 3 r 102 67 1~4 83 MN 500 2) :[ 4.00 2.63 :.- 440 4.0 '.1 3450 6. 3 102 - 67 )94 107 1 1.9 - 'mm .20 500 2.75 2.88 4.00 4.00 20 7.64 4.29 80 3450 69.9 ' 73 102 102 67 194 109 34 - i () 970 500 750 ;31 4.50 2.63 753 4.88 6,8' 6.5 80 31150 &. .84 114 124 3.1 3.0 475 36 7.4 1 76 9..J va)45 359 . 3.3 ': 121 121 80 94 34 34 - ' . 435 5 A16 2 80 .Z_ .!!.. 500 7~ - " .,' 4.7 7 79 63' i.. '3121 7,1,1 mjTi 920 4.75 3.15 .1., 8.0 -- 171 80 2".m .9 - 3.6 500 3,50 dl 500 4.53 315 9.70 531 8.4 88 63 3450 89 97 127 118 80 246 135 3.8 4.0 - ,, 2 - 500 2.% '3,75 4,50 3.17 800 .88 1 3 8.0 so 3450 63.5 ' 95 114 - 31 203 99 3.5 - 3 -. 920 500 350 5,81 J 5.00 3.00 9.46 ' 5.31 8.0 80 3450 8.39 97 177 76 240 135 36 - TABLE CONTINUED ON PG. 4 n www.vlctaullc.com V!CTAUUC 13 A REGISTERED TRADEMARK or VICTAULIC COMPANY. 2007 VICTAUUCCOMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA /otau STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE.TKREADEO OUTLET Provides a direct branch connection at any location where ,a hole can be cut in the pipe A pressure responsive gasket prOvides the seal Request Pubricatfon 11.03 for Mechanical-T crass assemblies Pressure rted'up to 00sU3450kPa on steel pip also available for use with HDPE pipe Sizes from 2xW/50x 15mm through 8 x 47,200 x 100mm IPS CARBON STEEL PIPE HOLE CUT PRODUCTS rtL,IrItjMIlUN tt.,IIUN IL U Size No Pressure Diflif-mions Weight Lich UL 5I ' j k139,7 TAELE CONTINUED FROM PAGE 3 11 5007430 774$O a23I3S7L) 40 330 3450 508 6 114 4 209 88 32 - 500 2515 5 450 '31) 62 88 9.0 3450' .633 93 114 - 84 21)9 99 4I - 500 2" 473 13 ..o ri m 0 usa f, - 4 - 251) 463 32 970 566 5i lip [1450 - ' 689 118 :80 245 135 500 .330 3.81 5.00 483 3,16 os .53a 140 14.2 813.9 3450. 88.9 95.00 127 118 80 230 137 64 64 8 (a) 500 175 443 3.79 915 32$ 4.8 150 3 fb} 3450 443 112 96 232 $3 22 I 15 (a) 1' 92ON 500 7.00. 4.40 5.13 513 3,79 915 3.25. 5.4 5.1 40 b) 3450 50,8 112 130 130 96 2321 $3 214 23 920N 500 2.50 4 8 5 3 5.13 370 915 328 6) 56 50 340 635 1 130 130 96 232 99 27 25 24)4)1 500 2.75 533 517 559 19.51 4.53 43 7.6 65 3450 597319)31) 130 94 267.3 3.8 3,4 920 500 rsr /S 5.21 3.59:0.5' 4,63 8.4 3450 * 889 132 04 267 8 38 920Q i 500 99 453,8 84 3 (all ) 50 lyj tl 50 P) 513 3094 3.59 103 I 70 88 4 (a)t 10.516.25 101 101 0 500 4.50 3.81 1 5.75 5.38 369 3450 1143 97 146 137 94 267 159 4.6 4.6 1590 x 1 V4 92014 500 17$ 4.43 5.13 3.63 9A0, 325 9.0 8.7 1 3450 445 113 130 - 92. 3391 83 4.1 43) 115(a) 500 2.00 4,41 5,13 3.63 9:40 3.25 72 40 93014 3430. 50.)) 1? ISO * 92 288 .5)) 33 - 2(a) 500 2.50 438 333 3,53 940 4.88 80 fo 3450 63.5 !It lao 3.6 ,, 920 3450 500 13 5. 130 . 363 92 mm 2.73 6373 "1 140 949 4,i3 239 '45 93 0 93 43 500 340, 439 550 84 1,4.0 5.13 343 34j 531 50 3450 88.9, 90 140 130 92 288 135 3,7 64 500 4.50 5.38 3.63 9140 0.12 mm 10.0 - 3450 -- ' - 1143 37 92 239 155 - 45 4 ' 20 500 1 430 321 575 363 940 1 625 180 100 1 340 1 1143 146 - 92 239 1 159 8.2 - TABLE CONTINUED ON PG. 5 O 0 IMPORTANT NOTES Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com IICTAUUC IS A REGISTERED TRADEMARK OF VICTAUUC COMPAN'( 02007 VICTAUUC COMPANY ALL RIGHTS RESERVED PRINTED IN THE tr& . \A"~Slu_ficr 'II fV) A call I Ati 7Q=;'te., ie Diameter Ta fflm E lnclmm inc A B C 2* 50 2.375 1 60.3 11/4 42 16.00 406 7.90 201 i 710 180 5.70 145 8.90 226 19.9 9.0 21/2 2.875 11/4 12.00 8.41 6.18 4.25 9.76 22.7 65 73.0 42 305 214 157 108 248 10.3 3 3.500 1 11/4 12.00 9.42 6.18 4,25 9.76 23.2 80 889 42 305 239 157 108 248 10.6 4 4.500 2 12.00 9.90 7.25 5.00 10.15 30.3 100 114.3 60 305 252 184 127 258 13.8 6 1 6.625 2 12.00 10.85 8.31 6.00 10.15 36,7 150 168.3 60 305 276 211 154 258 16.7 FireLock® Zone Control Riser Module SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS SERIES 747M SERIES 747MP (PRESSURE RELIEF OPTION) Designed for NFPA 13 commercial requirements, the Victaulic Series 747M Zone Control Riser Module features a cast body, and is compact and easy to install in zoned wet sprinkler systems. The integrated module body consists of a shut off valve, test and drain valve combination and different orifice sizes (K factors), a UL Listed and FM Approved Flow Switch, and a Pressure Gauge. The Series 747M FireLock Zone Control Riser Module is available in sizes from 2½ through 6765mm - 150 mm with grooved ends for easy installation in the horizontal or vertical up-flow positions with standard Victaulic grooved couplings. The Series 747M FireLock Zone Control Riser Module is FM Approved and UL and ULC Listed for working pressures up to 300 psi/2068 kPa). In addition, an optional pressure relief version is available. DIMENSIONS STYLE 747M PATENT PENDING Orifices: For 2.5 and 3" modules: K5.6, K6.9, K8.0 and K11.2 For 4' and 6 modules: K5.6, K6.9, K8.0, K11.2, K14.0 and K16.8 Note: Pressure Relief Option must be specified when ordering product. There is no field retrofit option for the standard Series 747M riser module. * For the 2/50 mm nominal size, the Style 747 Riser Manifold Assembly is provided. The pressure relief version of the 2/50 mm size is the Style 747P Riser Manifold Assembly. Module Body: Cast from ductile iron conforming to ASTM A-536, grade 65-45-12 with integral Victaulic grooved ends. Finish: orange enamel. Shut-off and Test/Drain Valve: Chrome plated brass ball, 5 37700 brass clapper, 416SS or 41OSS shafts, Delrin orifice, virgin Teflon*, enhanced Teflon and EPDM rubber seals. *Teflon is a registered trademark of Dupont Coupling: For sizes 2 ½' - 6765 mm - 150 mm, Victaulic Style 005 FireLock® coupling complete with Grade "E" - Type A Gasket. For sizes 2 ½ - 4765 mm - 100 mm, Style 009 FireLock EZ rigid coupling also available. Refer to Victaulic Submittal Publication 10.02 (style 005) and Submittal Publication 10.60 (style 009) for additional details. Any UL Listed, FM Approved Victaulic coupling may also be used. Note: Couplings not included with product. Waterf low Detector: System Sensor Model WED vane type waterflow detector with sealed retard, visual switch activation, and mechanical delay adjustment. Cover includes tamper resistant security screws and tool. Note: ULC models WFDA include cover tamper switch. 2½ - 6/73.0 - 168.3 mm Sizes (Valves shown above in the 'test" position. Shown with Pressure Relief Option) Hose Clamp Pressure ReliefValve .? Barbed Fitting Hose Clamp Close Nipple '-Drain Tubing Elbow Barbed Fitting Optional Pressure Relief Version Detail MATERIAL SPECIFICATIONS JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com viclAuLic IS REGISTERED TRADEMARK OF vlcrAuLic COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PFV F JtE1IUIiC 1r) QA 1 U1i FireLock® Zone Control Riser Module SERIES 747M SERIES 747MP (PRESSURE RELIEF OPTION) O WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. WARNING A I A WARNING This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Company, P.O. Box 31, Easton, PA 18044-0031 USA, Telephone: 001-610-559-3300. 11111 I ID I.Il 111111 II lii II 11111111111 III* WCAS-7ESN F2 For complete contact information, visit www.victaulic.com 10.96 3089 REV E UPDATED 5/2008 VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. A-c—ta—ulie in qi Upright Pendent Con onal Recessed Pendent/F1/F2 Horizontal Sidewall Vertical Sidewall S.. Concealed Pendent Recessed Pendent/FP Recessed Horizontal Sidewall XLH Recessed Pendent FP Bulletin 014 Rev. J co C 0 -i CD R Model Fl FR Series li'able- Quick Response Standard Spray Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall • Horizontal Sidewall Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS SchadenverhUtung GmbH NSF Certified to NSF/ANSi Standard 61 Annex 0 UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have XLH Upright XLH Pendent XLH Recessed Pendent F1/1`2 to apply water to a fire much faster than standard sprinklers of the same tem- perature rating. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types . Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content . demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response. enables the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers The ReliableReliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 %JF& OcLi I iui'i .o Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. PTh tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup O14FCO6A Model F1FR42, F1FRXLH Upright Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Working Working Finish Size Pressure Pressure Rating F1FR56 **F1 FR56LL 1 K 5.6 Quick 1/2' NPT See See F1FR42 **F1FR42LL(1) K 4.2 Response (R1/2) 175 PSI 7 PSI Temperature 'Finish Table" F1FRXLH Ratings" Table. F1FR28 K2,8 1) Low Lead Sprinklers available only with Temperature Rating 20017/931O Material Data: Frame Deflector Load Screw *pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDA Alloy510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape 2. 0 SPECIFICATION SECTION 2.8 O Model F1FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN Orifice Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2 (15mm) (') 1/2' NPT (1`11/2) 5,6 80 2.25' (57mm) 1,2,3,4 RA 1425(1)12)(3) 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA14231 RA1413 3/8" (10mm) 1/2" NPT(R1/2) 2.8 40 2.25" (57mm) 1 RA 1421 (11 RA1411 Conventional-Install in Upright or Pendent Position 15mm (i) 1/2" NPT (R1/2) 5.6 1 80 1 57mm 3,4 RA1475 3 cULus listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. S Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Orifice Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm)1 F_1/2" NPT(R1/2) 5.6 80 2.25" (57mm) 1,5 RA1414 7/16(11mm) [ 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1,5 RA1413 (I) cULus listed corrosion resistant (Polyester coated) sprinkler. 3. Vertical Sidewall ri Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 02rn.m)-2..(3 .5 nn )........ Pendent .4"( 4"(102mm):iOLJ SPECIFICATION SECTION 2.8 Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2' (15mm) 1/2 NPT(R1/2) 5.6 80 2.25" (57mm) 7/16" (10mm) 1/2" NPT(R1/2) 4.2 60 2.25" (57mm) RA1413 3/8' (10mm) 1/2" NPT(R1/2) 2.8 40 2.25' (57mm) RA1411 (1) Refer to escutcheon data table for approvals & dimensions Model F1FR56LL & F1FR42LL Quick Response Recessed Pendent Sprinkler1 Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number Orifice Size us r Metric Height (SIN) 1/2" (15mm) 1/2" NFT(R½) 5.6 80 2.25" (57mm) RA1414 7/16" (10mm) 1/2" NPT(R1/2) 4.2 60 2.25' (57mm) RA1413 (1) Refer to escutcheon data table for approvals & dimensions O U2P ss \ Al ~INWU. RECESS AWI SIMET ,=1• -. / ,J ft M:N,sus RECESS - 5/&79 S,?,,3 AT —vuu RrcM 713 T22 2-1 1A1 :1112 RECESS 11814~18. 62- AT ICCESS 1-1/R -Ij Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Fl or F2 I X 112' REDUCER 2 5/8 166 7J 2 5//5 SR. f58.7m] 1' CUP A CEUNG FACE Or FIT11NI 10 FACE OF CELIAC /21J ANUSTAIENT ArAREfMuM RECESS 9/16[I4J's',J At AIfIIR,JM RECESS 1725.4—j 31/42' Z6. Model F1 FR56, F1FR561-L, F1FR42, F1FR421-L, F1FRXLH & F1FR28 FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler US I i Metric Orifice Thread Size Height Organizations Identification Numbers (SIN) ½" (15mm) 1/2" NPT(R1/2) 5.6 8.0 2,25" (57mm) 1,2,3,4 15mm 1/2" NPT (R1/2) 5.6_J 8.0 2.25" (57mm) 40) RA1485(21 LPC Approval is for pendent position only. cULus Listed corrosion resistant (Polyester coated) sprinkler. S SPECIFICATION SECTION 2.8 Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Sprinkler Approval Organizations Nominal K Factor Height and Type of Approval Sprinkler Nominal Orifice Thread Size - Identification US Metric Light Hazard Ordinary Numbers (SIN) 1/2" (15mm) 1/2' NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 iRA1435"2 (1) cULus Listed corrosion resistant (Polyester coated) sprinkler. 72/ Polyester coated FM approved sprinkler. Horizontal Sidewall 7/772 TI ESCUTCHEON lU AT MAXIMUM RECESS = 1-3/8"[34.9mm] 7 AT MINIMUM RECESS = 2- 1/)6'[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS 7-5/8741.3mm1 I_ AT MINIMUM RECESS = 2- 7/76752.4mm] - [3.2mm] 2 27/32" 0/A. [72.2mm] —) I Fl ESCIJTCHEON 3/4 "[79mm] ADJUSTMENT 62 ESCUTCHEON 1/2712.7mm] ADJUSTMENT FACE OF FITTING TO FACE OF CEILING DIMENSION F; ESCUTCHEON AT MAXIMUM RECESS = 7725. 4mmJ AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS 3/4719mm] AT MINIMUM RECESS = 3/879.5mm] -2 7/4" HOLE 0/A. I [57.2mm] I" 2' (/2' REDUCER 75/16" DIA.' I [49.2mm] TURN COLLAR UNTIL .- TIGHT AGAINST SPRINKLER WRENCH BOSS. V (1) 4"-I2 [701.6mrn-304.8mm] CEILING TO DEFLECTOR S RECESSED HSW W/F1 OR F2 ESCUTCHEON (7) FM APPROVED FOR 4" - 5' [107.6MM - 752.4MM] CEILING TO DEFLECTOR. Note: For Recessed HSW Sprinklers use installation wrench GFR2. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: "K" Factor Temp. Rating Max. Sprinkler Nominal Thread Model Ambient Bulb Approvals Identification Orifice US Metric Size Sprinkler Cover Temp Color Number(SIN) 1/2" (15mm) 5.6 80 ½" NPT F1 FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1 RA1414 1/2" (15mm) 5.6 80 ½" NPT F1FR 155°F/68°C 1 1350F/570C 100°F/387'C Red 1,40) RA1414 '/2" (15mm) 5.6 80 1/2" NPT F1 FR 175°F/79°C 165°F/740C 100F/38°C Yellow 1 RA1414 ½" (15mm) 5.6 80 1/2" NPT F1 FR 200°F/930C 165°F/74°C 150°F/65°C Green 1 RA1414 (1) For VdS only = 1550F/68C Norbuib and 1/2' [12,7mm] adjustment. Model Fl FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RO1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread Size Model Temp. Rating Max. . Ambient Color Bulb Approvals Sprinkler Identification US Metric -----________ Sprinkler Cover Temp Number(SIN) 1/2" (15mm) 5.6 80 ½ NPT F1FR56LL 200°F/930C 165°F/740C 150°F/650C Green 1,5 RA1414 5. JI I_'.JII l'.Jt't I FL'r JLJ I R_IlM _.0 x 1/2" REDUCING TEE OR ELBOW ---H "" 25/16"D14— HOLE IN CEILING CUP 03$ 1 1/2 MAX FACE or FITTING To FACE OF CEILING I DIMENSION CEILING-' ' COVER ADJUSTMENT 15/16" COVER PLATE A,,EMNLY SPRINKLER CONCEALED 1/2' ADJUSTMENT Figure 1 Installation Aid A protective cap is included for use during installation, Important: The Fl FR56 Sprinkler with Model CCP cover plate is not an FM Approved combination, Installation Quick response sprinklers are intended for installation as specified in NFPA 13, Quick response sprinklers and stan- dard response sprinklers should not be intermixed, The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight 1/2" NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LL/CCP Concealed Sprinkler use the 1/2" orifice, ½" NPT (R112), Model F1FR56 & Fl FR56LL Pendant Sprinkler with a threaded Model CCP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C). The Model F1FR56LL Pendant is available only in a rating of 200°F (93°C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model CCP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the Fl FR56 and 165°F (74°C) for the F1FR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- *DuPont Registered Trade Mark 6. 1" xi/2 REDUCING TEE OR ELBOW " fl- 25/8" 0/A. 2 5/16" 0/A IN CEILING CUP FMT 1 1/2' MAX. FA CE OF FITTING To FACE orrriLuAr DiMENSION CE1111 1. 5116" MAX, 314 COVER AOJIJSIMENI COVER PLATE ..............// if ASSEMBLY T J 5/16 0/A, SPRINKLER CONCEALED, 5/16" ADJUSTMENT Figure 2 gagement. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8" (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2!" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1FR56 Pendant Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. rtL4rIL'I I IL)I\I L# ILJI\i O Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. I Bulb Color OC OF Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) 1 Yellow Intermediate 93 200 150°F (66°C) Green High (1) 141 286 225°F (107°C) Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) SIN RA1435 - cULus permits use with Fl, F2 or FP escutcheons for "light hazard only, while FM limits use for same hazard with F2 escutcheon only. Maintenance The Model F1FR56, F1FR56LL. F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL. F1FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover platet Bronze Brass Chrome Plated Chrome Chrome Polyester Plated White Coated_4)(5))6) White Painted Specii' Application Finishes Sprinkler Escutcheon I Cover pIate1> Bright Brass (3) Bright Brass Bright Brass Black Plated Black Plated Satin Black Paint (2))6) Black Paint Off White Off White )2)(6) Off White Black Paint Satin Chrome Satin Chrome Black Plated Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW). RA1485(vSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated' applies to SIN Number RA1414, RA1435 and RA1 425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, AA1414 and RA1475. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. ¼.) I L. Ia II I I 1 ¼.) I_ ¼1 I I'./I I . I..) Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections. Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection S The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by 0 The Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper R (800)eliable 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 02/13 P/N 9999970300 Bulletin 136 Rev. 0 Re Model Fl FR LO Model Fl FR LO Recessed lab-le Quick Response Sprinklers 01 S Model Fl FR LO Sprinkler Types Standard Upright Standard Pendent Conventional Model Fl FR LO Recessed Sprinkler Types Recessed Pendent For Model F1FR ½' K 5.6 (80), 4.2 (60) & 2.8 (40) Sprin- kler Types refer to Bulletin 014 for technical specifica- tions and approvals. Listings & Approvals Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters' Laboratories of Canada (ULC) Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) Verband der Schadenversicherer Gmbh UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler ULGuide Number VNIV Product Description Reliable Models F1FR LO and F1FR LO Recessed Sprin- klers are quick response sprinklers which combine the du- rability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1FR LO and F1FR LO Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprin- klers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR LO and F1FR LO Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same tempera- ture rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid Conventional Recessed Pendent (Model FP Shown) to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. The temperature rating of the sprinkler is identified by the color of the glass bulb. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2-8N or other applicable standards. Quick response sprinklers and standard response sprinklers should not be intermixed. Installation Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2-8N or other applicable standards. Quick response sprinklers and standard response sprinklers should not be intermixed. The Model F1FR LO Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR LO Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. Upright IT) Pendent The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 SF'ECIHUAFION SEC ION 2.8 DEFLECTOR LOAD SCREW SULB WASHER / / / \ cu FRAME i . 3&rGp2 Technical data: Models Response Deflector Discharge Thread Max. Working Mm, Working Temperature Finish Orientation Coefficient Size Rating Pressure Pressure F1 FR LO Quick Upright Pendent K 8.0 3/4" NPT(R3/4) 175 PSI 7 PSI ' See Temperature See 'Finish Response Conventional or 3/4" BSPT Ratings" Table Table" Material Data: Frame Deflector Load Screw I Cup I Washer I Bulb DZR Brass CDA Alloy 210, 220, 314, 316, 360 I or CDA Alloy 314 Nickel Alloy 440 or Alloy 360 QM Brass CDA Alloy 510 CDA Alloy 544 I or CDA Alloy 353 coated with PTFE Adhesive Tape Glass See "Installation Data" table and from page for more details SPECIFICATION SECTION 2.8 Model Fl FR LO Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type K Factor Sprinkler Height Approval Organization Sprinkler Identification Numbers (SIN) US Metric SSU I SSP Standard-Upright (SSU) and pendent (SSP) Deflectors Marked to Indicate Position CrtT32(2tTmhL5rte Ufltic wjtn NFTTFd Conventional-Install in Upright or Pendent Position 20mm Large Orifice with 3/4" NPT (R3/4) Thread 1 8.0 1 115 1 58mm 1 4,7 R3672 Polyester coated upright UL and ULC listed corrosion resistant R3622. FM Approved for polyester coated sprinkler. R3622 Upright Pendent Conventional • j Model Fl FR LO Quick Response Recessed Pendent Sprinkler0 Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size "T" Nominal K Factor I I Sprinkler I Height I Approvalt1> Organization I I Sprinkler I Identification I Numbers (SIN) US i I Metric I Fl I F2 :[:FP 17/32" (20mm) 3/4" NFl (R3/4) 8.0 115 2.3" (58mm) 12,8 123,8 1 1,2 R3612 (1) Refer to escutcheon data table for dimensions. S - C ye OWUCES A=N ST SF NFL H c. va~ FACE OF FIMNG V1 1AXI.W. PUCE AT MINIMUM arc-EON HDJUDTME/T !rmJ - 71 J:2HTm DA RECESSED PENDENT W/F1 OR F2 ESCUTCHEON SFRLNQER NO EM 40030000 WON El ESCUTCHEON C 3/4 REDUCER 2 5/0 CIA. [0071m] HOLE IN CEILING 2 5/16 014. (110 UCla,] CLIP CEILING I t.J FAC" CF F/TIlE AT MAXIMUM PEC-155 9116*114.J-1 '/4750.0mm] AT MINIMUM PEC.SS 1725.4-1 ADJUSI/IFILT 3 l/A 014. - (82.6mm] RE.ES.EDPENOENI....../.E.PESCUTCHEON SPRINKLER OCT FM APPROVED wON FE ESCUTCHEON 3. When installing Model Fl FR LO Sprinklers, use the Model D Sprinkler Wrench. When installing Model F1FR LO Re- cessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Note: A leak tight 1/2" NPT (Rl/2) sprinkler joint can be obtained with a torque of 8 - 18 ft-lbs (10.8 - 24.4 N-m). Do not tighten sprinklers over maximum recom- mended torque. It may cause leakage or impairment of the sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS, Temperature Ratings Classification Sprinkler Temperature __ Maximum Ambient Temperature Bulb Color °C OF °C OF Ordinary 135 57 100 38 Orange Ordinary 155 68 100 38 Red Intermediate 175 79 150 66 Yellow Intermediate 200 93 150 66 Green High'" 286 1 141 225 107 Blue Not Available for recessed sprinklers. Maintenance The Models F1FR LO and F1FR LO Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other clean- ing fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Finishes 12 Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated ') White Polyester Coated(4)(5) White Painted (3) Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White(l) Off White Satin Chrome Satin Chrome " Other finishes and colors are available on special order. Consult the factory for details. FM Approvals is limited to bronze and brass, chrome or black plated finishes only. FP Push-on/Thread-off escutcheon. ' UL and ULC listed corrosion resistance. SIN number: R3622. 5) FM Approved for SIN No. R3622 Note: For 1/2" orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprin- klers refer to Bulletin 014. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Note: When Model F1FR LO Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured-by The Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper Reliabile (914) 829-2042 Corporate Offices (800) 848-6051 Sales Fax Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A 07/12 P/N 9999970027 Bulletin 034 Rev. C He Model G5-80, Model G5-56, Model G5-42, Model G5-28 lable Quick Response Concealed Automatic Sprinkler w 9- (D 0 CA) I S UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4" (19mm) Adjustment Features Cover plate attachment (Plain or Perforated) with 3/4" (19mm) assembly adjustment. Smooth aesthetic ceiling profile. Factory installed protective cap. Available in Chrome and White as Standard Finish- es. Special Application Finishes are also available. Ordinary and Intermediate temperature rating. For additional Sprinklers refer to Bulletin 154 for Technical Specification and Approvals Approvals & Listings 1. Underwriters Laboratories Inc. and cULus - Quick Response G5-80, G5-56 - Light Hazard and Ordinary Hazard Occupancies G5-42 - Light Hazard Occupancies G5-28-Light Hazard Occupancies 2.(Factory Mutual Research Corp. (FM) -: ndard Page3 See the most recent FM Global Property Loss Prevention Data Sheets for installation and use guidelines. 3. Loss Prevention Council (LPCB, UK) - Standard Response G5-56 - Light Hazard and Ordinary Hazard Occupancies VdS Schadenverhutung GmbH - Standard Response [C-Certificate of Conformity 0832-CPD-2062 U.S. Patent number 6,554,077. Application The Reliable Model G5-80, G5-56, G5-42 and G5-28 are the most versatile quick response concealed sprinklers avail- able. It provides the best form of fire protection while offering an attractive appearance and 3/4" (19mm) of cover adjust- ment for ease of installation. The small diameter cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an au- tomatic sprinkler system. Perforated Cover Plate The Model G5-80, G5-56, G5-42 and G5-28 are designed for use where aesthetic appearance is important. Offices, hos- pitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13. FM Approves the G5-56 and the G5-28 sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. Product Description The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides 3/4" (19mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model FC Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Installation Do not install the 05-80, 05-56, 05-42 and 05-28 in ceilings which have positive pressure in the space above. Cut a 2/8" inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER! CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G5-80, G5-56, 05-42 and 05-28 should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. Concealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information 1 Sprinkler Model Nominal Orifice Flat Cover Plate Plain or Perforated Flat Cover Plate Assembly Finish Inlet Type Cover Plate Finishes 11 Standard Finishes Chrome White Paint Special Application Finishes 2t Bright Brass Finished Bronze Black Plating lack Paint) Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) For the perforated style cover- plate, consult factory for avail- ability on these and other cus- tom finishes. Maximum Working Pressure 0 175 psi (12 bar) 100% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating Classification Sprinkler Cover Max. Ambient Plate Temp. Ordinary i 65°F/74°C 135°F/570C 100°F/38°C Intermediate 212°F/1 00°C 1650F/740C 150°F/660C 2. I Technical Data Sprinkler Model Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor Thread Approvals Sprinkler Identification (SIN) US Metric G5-80 Non Adjustable 3/4" (19mm) 732' (15mm) 8.0 115 34" NPT(R3/s) 1 RA3412 (5-56 Non Adjustable 114' (19mm) ½" (15mm) 5.6 80 1 1/2'1NPr(AV2) 1,2,5 RA341) G5-42 Non Adjustable -3/4" (19mm) 7/" (10mm) 4.2 60 ½" NFT (R1/2) 1 RA3413 G5-28 Non Adjustable 34"(19mm) 1/8" (10m 2.8 40 ½" NPT (R'/PL 1,2 RA3411 For VdS Approval, temperature rating sprinkler 1650F/74°c and cover plate 1350F/570C only! S /" x 7/2" REDUCING " ,- 3/4" REDUCING TEE OR ELBOW I TEE OR ELBOW G5-80 ONLY TT1 I ' 2f" [58.42mm] 0/A HOLE IN CEILING CUP -'---._ 2-1/4" [50.8mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING -I " [19.05mm] MAX. COVER ADJUSTMENT FLAT COVER PLATE ASSEMBLY SPRINKLER [84.2 1mm] 0/A. [4.96mm] COVER PLATE: 3/4 " [19.05mm] ADJUSTMENT Notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS 1" x 1/2" REDUCING TEE OR ELBOW 11jLL: RELIABLE P/N 6999991900 3' X 3" BRASS NIPPLE EXT. -. 2k" [58.42mm] 0/A CUP CEILING [19 05mm] MAX J COVER ADJUSTMENT A FLAT COVER PLATE' ASSEMBLY r- SPRINKLER 3" [84.2 1mm] 0/A. 2" [66.55mm] HOLE IN CEILING 3-1/IE' [77.72mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 2-1/4" [50.8mm] MAX. FACE OF NIPPLE EXT. TO FACE OF CEILING DIMENSION - ' [4.96mm] 03F002 COVER PLATE: 3/4" [19.05mm] ADJUSTMENT Testing has shown that use of a nipple extension" will not affect the listing of the sprinkler. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, "which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems". Do not exceed 8-18 ft-lbs of torque during installation, 3. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains 40 Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper II eIiaPIe (800) 848-6051 Ss Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 11/13 P/N 9999970421 SPECIFICATION SECTION 2.9.B SYSTEM $ SENSOR SSM/SSV Series Alarm Bells System Sensor's SSM and SSV series alarm bells are low current, high decibel notification appliances for use in fire and burglary systems or other signaling applications. Features S . Approved for indoor and outdoor use Low current draw High dB output Available in six-inch, eight-inch, and ten-inch sizes AC and DC models DC models polarized for use with supervision circuitry Mount directly to standard four-inch square electrical box indoors SSM and SSV series come pre-wired Reliable Performance. The SSM and SSV series, Provide loud resonant tDnes The SSM series operates on 4VDC and are motor driven, w le the SSV series operates on 120VAC utilizing a vibrating mechanisr. Simplified hstallton. For indoor use, the SM and SSV series mount to a sta:dard four-inch square electri-:a bc. For outdoor applicatio.-i;, we athrproof back box, model number WBB, is used. The SSM and S/ setie; :ome pre-wired, to re-_L -.E installation time. The SSM se. ries icorporates a polarized elec:rical design for use with supervision cbcitry. Agency Listings ® MEA LISTED APPROVED approved 54011 C5549 3005255 7135-1653:0217 331-01-E SPECIFICATION SECTION 29.13 SSM/SSV Specifications Architectural/Engineering Specificatioris'~ Model shall be a SSM or SSV Series alarm bell. Bells shall have underdome strikers and operating mechanisms. Gongs on said bells shall be no smaller than nominal 678710" (specify size) with an operating voltage of 24VDC or 120VAC (specify by part number). Bells shall be suitable for surface or semi-flush mounting. Outdoor surface mounted installations shall be weatherproof (using optional WBB weatherproof electrical box). Otherwise bells shall mount to a standard 4" square electrical box having a maximum projection of 2½". Bells shall be located as shown on the drawings or as determined by the Authority Having Jurisdiction. Bells shall be listed for indoor/outdoor use by Underwriters Laboratories and the California State Fire Marshal, and approved by Factory Mutual and MEA. Physical/Operating Specifications Operating Temperature Range —31°F to 140°F Operating Voltage SSM series: 24VDC SSV series: 120 VAC Termination Provided with 2 sets of leads for in/out wiring Service Use Fire Alarm, General Signaling, Burglar Alarm Warranty Electrical Specifications 3 years Model Gong Diameter Nominal Voltage Operating Voltage Maximum Current Sound Output (dBA) (inches) Limit SSM24-6 6 Regulated 24VDC 16 to 33VDC DC-3 1.1 mV FWR-53.5mA 82 SSM24-8 8 Regulated 24VDC 16 to 33VDC DC-31 .1 mA! FWR-53.5mA 80 SSM24-10 10 Regulated 24VDC 16 to 33VDC DC-3 1.1 mA! FWR-53.5mA 81 SSV120-6 6 Regulated 120VAC 96 to 132VAC 53mA 85 SSV120-8 8 Regulated 120VAC 96 to 132VAC 53mA 82 SSV120-10 10 Regulated 120VAC 96to132VAC 53mA 82 Sound output measured at Underwriter Laboratories, as specified in UL464 S Ordering Information SSM24-6 SSM24-6A _ Bell, 6, 24VDC, Polarized, 82dBA SSM24-8 SSM24-8A Bell, 8 24VDC, Polarized, 80dBA SSM24-10 SSM24-10A Bell, 10", 24VDC, Polarized, 81dBA SSV12O-6 SSV120-6A Bell, 6", 12OVAC, 85dBA SSV12O-8 SSVI20-8A Bell, 8", 12OVAC, 82dBA SSV12O-10 SSV12O-10A Bell, 10-1 120VAC, 82dBA WBB Weatherproof back box for SSM and SSV series, when installed outdoors 1 "S TEM VII .5ltJSR 02011 Syster, Sensor. 3825 Ohio Avenue St. Charles, IL 60174 Product speciñcaons subject 10 change without notice. Visa enocorfor Phone: 800-SENSOR2. Fax: 630-3/1-6495 cuntprun1o;dgthe latest verbnof this data sheet. SPECIFICATION SECTION 2.9.0 SYSTEM SENSOR WFD Series Waterfiow Detector The System Sensor WFD series is compatible with schedule 10 through 40 steel pipe, sizes 2" through 8'; and can be mounted in a vertical or horizontal position. Features Two-inch mounting hole provided in new WFD30-2 models UL-listed models are NEMA 4 rated Sealed retard mechanism immune to dust and other contaminants Visual switch activation Field-replaceable retard mechanism and SPDT switches Rugged, dual SPDT switches enclosed in a durable terminal block Accommodates up to 12 AWG wire Designed for both indoor and outdoor use 100 percent synchronization activates both alarm panel and local bell Tamper-resistant cover screws Agency Listings & @ 0 MEA LISTED approved APPROVED 5739 C0169 7770-1653114 167-93-0 3006195 Robust Construction. The WFD series consists of a rugged, NEMA 4-rated encFosure. Designed for both indoor and outdoor use, the WFD series operates across a wide temperature range, from 32°F to 120°F. Reliable Performance. LL-listed models are equipped with tamper-resistant cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal block to a;sure reliable performance. False Alarm Immunity.The WFD series incorporates a mechanical retard feature, which minimizes the risk of false alarm due to pressure surges or air trapped in the sprinkler system. In addition, the mechanical retard's unique sealed design is immune to dust and other contaminanis. Simplified Operation. The WFD series is designed to simplify installation. Two conduit openings permit easy attachment to the local alarm system. The retrd mechanism and dual SPDT switches are field-replaceabie. 1W15 RETARD TIME MAY EXCEED OOSECXNDS.ADJUET AND VERIFY THAT TIME DOES NOT EECEEDEESEEONBS. B bolt nut pipe * II-IL/k I ION btU I ION .L. Waterf low Detector Specifications Vane-type waterfiow detectors shall be installed on system piping as designated on the drawing and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least 6" from any fittings that may change water direction, flow rate, or pipe diameter or no closer than 24" from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi* for 2"- 8" pipes. The detector shall respond to waterfiow in the specified direction after a preset time delay that is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detetors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or outdoor use. Static Pressure Rating 450 PSI* Operating Temperature Range 32°F to 120°F (0°C to 49°C) Maximum Surge 18 Feet Per Second (FPS) Enclosure Rating* NEMA 4-suitable for indoor/outdoor use Triggering Threshold 4-10 GPM Cover Tamper Switch Standard with ULC models, optional for UL Bandwidth (Flow Rate) models, part no. 546-7000 Conduit Entrances Two openings for ½" conduit. Service Use Automatic Sprinkler: NFPA-1 3 One open, one knock-out type One orTwo Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA-72 Contact Ratings Two sets of SPDT (Form C) U.S. Patent Numbers 5,213,205 10.0A,1/2 HIP @ 125/250 VAC 2.5 A@6/12/24VDC Compatible Pipe Steel water pipe, schedule 10 through 40 Warranty 3 Years WFD Field Wiring Diagram SSMDB'X NDTE:COMMSHANDB.NS Ut-LISTED COMPATBLE ssviao-x Q CONNECTIONS WILL CLOSE WHEN VANE IS DEFLECTED. I.E.. CONTROL PANEL WHEN WATER IS FLOWING. DUAL POWER * SWITCHES PERMIT APPUCATIONS TO RE COMBINES U400C OR DNA SINGLE DETECTOR. 120VDC - I CONTACT RATINGS I INITIATING SUGGESTED EOL IRESISTOR 12S/2vACI IDAMPSLOOP I I S4VDC I 2.SAMPS I SCTIEMATICOF INDIVIDUAL SWITCH IN NOWATERFLSPr I CONDITION t BREAKWIREAS $TD B),l SHOWN FOR SUPERVISION OF — CONNECTION. DO NOT ALLOW LEADS TOEXTEND STRIPPEDWIRE BEYONDSWITCH HiBIBj" HOUSING. SO NOT LOOP WIRES, Delay Adjustment Dial Overall Dimensions, Installed _ UL Model ULC Model Pipe Size Hole Size Shipping Weight WFD20 WFD20A 11/4 4.2 lbs. WFD25 WFD25A 21/2" 11/4 4.3 lbs. WFD30-2 WFD30-2A 2" 4.5 lbs. WFD35 WFD35A 31h" 11/4 4.7 lbs. WFD40 WFD40A 2" 5.2 lbs. WFD50 WFDSOA 2" 6.3 lbs. WFD600 WFD60A 2" 6.8 lbs. WFDBO° WFD80A 8" 2" 7.5 lbs. Accessories A3008-00 Retard mechanism A77-01-02 Terminal block 546-7000 Tamper-proof switch kit WFDW Tamper-proof wrench for cover WFDN4 Gasket kit *Maximum pressure rating 400 psi as approved by Factory Mutual. SYSTEM '...$ SENSOR 3825 Ohio Avenue St. Charles, IL 60174 Phone: 800-SENSOR2. Fax: 630-37'-6495 current Z)2009 System Sensor. Product specifications subject to change without notice. Visit systemsensorcom for product information, including the latest version of fts data sheet. PIBV2 Supervisory Switch System Sensor's P/B V2 supervisory switch monitors the open position of post indicator and butterfly control valves. Robust Construction: The PIBV2 rigged housing is intended for indoor and outdoor use When installed with the actuator in the vertical position, the P1BV2 is NEMA 332 rated per UL Application Flexibility: The P1BV2 eatures a flexible design, which accommodates post indicator, butterly, and many other types of wall post, recessed wall post and pressure reducing valves. The P1BV2's unique Di-directional actuator allows the uni t to be installed in either rising ci tall ng flag installations. Simplified Installation: Installatior. is made easier with the PlBV2's single side ccnduit entrance By providing a direct conduit pathway to tne. electrical source, rig t- angle fittings are not required. Installation is further simplified by the P1BV2's adjustable length actuator with a convenient breakaway feature for installation on shorter valves. This e iminates the need for cutting the shaft. Features S . NEMA 3R rated enclosure Bi-directional actuator Easy single side conduit entry Adjustable length actuator with breakaway feature Built to accommodate up to 12 AWG wire Two sets of SPDT contacts enclosed in a durable terminal block 100 percent synchronization activates alarm panel and local bell simultaneously Operating temperature range —40°F to 120°F (-40°C to 49'C) Tamper resistant cover screws Reliable Performance: The P1BV2 as 100 percent synchronization which activa:es the alarm panel anc local bell simultaneously. In addition, the switch s designed to cflerate in temperatLires ranging from —40F to 120°F H40°C to 49°C). The P1BV2 is equipped with tamper resistart cover screws to prevent unauthorized entry. Inside, two sets of SCT (Fom C) synchron zed switches are enclosed in a durable terrrinsl hlo:k to assure reliable performance. Agency Listings (X MEA LISTED "—' APPROVED approved S73° CS 169 7 7S-I8 18 OW°./8'Y 181-988 PIBV2 Specifications Model shall be model number PIBV2 Post Indicator Butterfly Valve supervisory switch as manufactured by System Sensor. P1BV2 shall be installed on each valve as designated on the drawings and/or as specified herein. Switches shall he mounted so as not to interfere with the normal operation of the valve and shall be adjusted to operate within two revolutions of the valve control or when the valve flag has moved no more than one-fifth of the distance from its normal position. the mechanism shall be contained in a weatherproof die cast metal housing, which shall provide a side entrance for ½"conduit and incorporate a W NPT nipple for attachment to the valve body. A grounding provision is provided.The switch assembly shall include two switches each with a rated capacity of 10 Amp 55 125/250V AC and 2.5 Amp @ 24V DC.The cover shall contain tamper-resistant screws for which a security wrench will be provided with each switch. PIBV2 shall be Underwriters Laboratories listed for indoor or outdoor use.The PIBV2 shall be Factory Mutual CSFM, and MBA approved. Overall Switch 4/4"H x 31/2, 'W x 3¼"D Contact Ratings Two sets of SPDT (Form C) Dimensions (10.8cm x 8.9cm x 8.2cm) 10.0 A @ 125/250V AC; 2.5 @6/12/24V DC Shipping Weight 2 lbs. (0.9 kg) Enclosure Rating UL indoor/outdoor NEMA 313 when mounted with the actuator vertical Operating Temperature —40°F to 120°F (-40°C to 49°C) Cover Tamper Switch Standard with ULC model Range Optional for UL model, part no. 546-7000 Maximum Stem Extension 3/32" (3.0 cm) Service Use Automatic Sprinkler: NFPA 13 One orlwo Family Dwelling: NFPA 13D Residential Occupancies up to 4 stories: NFPA 13R National Fire Alarm code: NFPA 72 Mounting ½' NPT nipple Warranty 3 years Conduit Entrances One single side open for ½" conduit U.S. Patent No. 5,213,205 CONTACT RATINGS 1251250VAC 1 10AMPS 24 VDC 25 AMPS Electrical Connections for PIBV2 Top View Switch * Gauge Switch2 Strip P1BV2 Mountin The following are examples of acceptable mounting positions: . Actuator Vertical (Down) Actuator Horizontal The following mounting position is not acceptable: Actuator Vertical (Pointing Up) Actuating Arm Breakaway Feature: ak here Sup. Switch Sup. Switch to nonsll:nceabie initlati IHH end resistor zone of listed FACP COM COM COM COM Typical FACP Connection to power source lH H H H compatible local with bell i -i Ni Ni -1 hi Break wire as shown for supervision of connection. DO NOT allow stripped wire leads to extend beyond Switch housing. 00 NOT loop wires. com Typical Local Bell Connection Ordering Information P1BV2 Post Indicator/Butterfly valve supervisory switch PIBV2A Post Indicator/Butterfly valve supervisory switch (ULC model) Accessories A3010-00 Replacement hardware kit (wrenches, screw pack) WFDW Replacement tamper proof wrench for cover 546-7000 Cover tamper switch kit HEXW Replacement hex wrench S07-66-XX Tamper screws for cover Th SYSTEA4 3825 Ohio Avenue St. Charles, IL 60174 ubjt nfor $ SENSOR' Phone: 800-SENSOR2. Fax: 630-3) 1-6ziQ5 A05-01V-01jP- 1. 11/06. #1676 Identification Signs S Description Manufactured from .020" white coated aluminum. All sign types are screen printed with a fade resistant red ink. Each sign is shipped with a clear protective plastic coating which can be re- moved at time of installation. Each sign type meets or exceeds NFPA13 requirements. All signs (except 7" round) are drilled in four corners to allow for easy installation. All signs (except 7" round) may be installed with sign chain or with any fastener that is suitable for the material that the sign is being attached. The 7" round bell signs are center drilled to allow for installation di- rectly to the bell gong assembly. Type "A" 9" x 7" Control valve signs are drilled with the same four hole pattern as Type "B" 6" x 2" signs to allow for attachment of Type "B" to Type "A". Installation Installation of aluminum signs through the top holes on the is accomplished by several signs and hung on the ap- methods. The most common propriate valve or piping. The installation procedure is to signs may also be fastened to use #16 Single Jack chain a flat surface with fasteners to hang the sign on the area appropriate to the base mate- being identified. Since all of rial. (The 9" x 7" Fire Alarm the above mentioned signs Bell sign must be drilled if it is are predrilled at all four cor- to be attached directly to the ners, the last link of the chain bell gong.) can be opened and hooked Specifications Material: 020" aluminum with -ernovable plastic :mating Sizes: 3"x2" 411 x 6" 5"x7" 12"x 10" 3.5" x 11' See current catalog for a full sting of all available signs. ©1996-2009 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc F P P I 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822• 1 800 344-3775 fax www.fppi.com 02-002-00 Blank Sign w/border 6" x 2" 1000 02-010-00 Air Line, 6" x 2" 1000 r0201400 Alarm Une 6 x2" _____________ 1000 02-018-00 Alarm Test, 6" x 2" 1000 022 00 Anti Freeze System 6x2 10o0] 02-023-00 Anti-Freeze System 5" x 7" 1000 24-00 AutoSpnnkler Shut Off 12x10__16 02-026-00 Auxiliary Drain, 6" x 2" 1000 [0203400 Control Valve, 6x2__100O 02-036-00 Control Valve, 4" x 6" 1000 02-037-00 Control Valve, 5" x r 1000 J 02-038-00 Control Valve, 9" x 7" 500 LI05 02-046-00 Drain Valve. 6" x 2" 1000 L02 050 00 DryStandpe6x2 i00 02-051-00 Fire Dept. Connection 6" x 2" 1000 iöO53 00 Excess Pressure Pump 6x 2 02-054-00 Entire System, 6" x 2" 1000 02-055-00 Fire Alarm Bell, 9 x7 5O 02-056-00 Fire Alarm Bell, 7" Round 500 05700 911 Are Alarm Bell 7 Ro und 02-058-00 F.S. Valve Do Not Close, 6" x 2" 1000 02-062-00 From City Main, 6" x 2" 1000 02-066-00 In This Building, 6" x 2" .1000 , 02-070-00 In This Section, 6" x 2" 1000 [740o Inspectors Tëst6x2 iU0J 02-077-00 Hydraulic System, 5" x 7" 1000 100 02-082-00 Main Control, 6" x 2" 1000 [6208600 Main DraIn 6x2__iooö] 02-091-00 Multi-use System, Warning, 5" x 7" 1000 1 02-092-00 Normally Closed, 6" x 2" 1000 02-096-00 Normally Open, 6" x 2" 1000 i2 098 00 _Open Spnnkler, 000 FIRE SPRINKLER RISER INSID"E S Sprinkler Identification Signs FPPI's Sprinkler Identification Signs are manufactured of aluminum, painted white then printed with "fade resistant" red ink. Each sign is drilled for easy installation and is plastic coated to prevent scratching of finish during shipment and final installation. Designed in accordance with NFPA requirements. ©1996-2009 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc FPPI 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax • www.fppi.com PpI Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines. The Spare Sprinkler Head Cabinets a available in six configurations. Three head, six head, six head ESFR, twelve head, twenty-fou head and thirty-six head. All six styles are manufactured with "knockouts" to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel finish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features two holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. Installation Select the correct Spare Sprinkler Head Cabinet in accordance with the Automatic Sprinkler Systems Handbook. As per the 1989 Edition the correct number of spare sprinkler is as follows: 0-300 sprinklers, not less than 6; 300-1000, not less than 12; 1000 or more, not less than 24. Stock of spare sprinklers shall include all types and ratings installed.* Once the correct Spare Sprinkler Head Cabinet has been selected, installation is accomplished by inserting the correct fastener in each of the two holes inside the cabinet, securing the cabinet securely to the wall. The insert the correct number and type of sprinklers in accordance with the "handbook". Specifications Material: Painted Plain Steel Finish: Red enamel Styles: 3 Spare sprinklers, 1/2 or Y4 6 Spare sprinklers, 1/2 or IY4 6 Spare, ESFR, ½, 3/4 or 1" 12 Spare sprinklers 1/2 or 3/4 24 Spare sprinklers 36 Spare sprinklers *Final determination is subject to approval by the AHJ. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1 800 344-1822 FAX + 1 800 344-3775 0 2012 Fire Protection Products, Inc.