Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; ; FPC2017-0051; Permit( PER1XT REPORT City of Carlsbad Print Date: 05/27/2022 Permit No: FPC2017-0051 Job Address: 2525 ELCAMINO REAL, CARLSBAD, CA 92008 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 1563020900 Track #: Applied: 02/21/2017 Valuation: $5,905,620.00 Lot #: Issued: 05/09/2017 Occupancy Group: Project #: Finaled Close Out: 02/02/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Fieri, Dominic Plan Check #: Wong, Cindy Project Title: Description: THE SHOPPES AT CARLSBAD -FIRE ALARM PHASE 1 Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS P0 BOX 3042 3568 RUFFIN RD BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-2597 (561) 341-7780 (858) 633-9123 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov SimplexGfinneII BE SAFE. A Tyco International Company SimplexGrinnell LP 3568 Ruffin Road San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com Fire Alarm System Product Submittal PROJECT: THE SHOPPES AT CARLSBAD 2525 EL CAMINO REAL CARLSBAD, CA 92008 ., For any questions regarding this submittal, please contact Douglas Daniels, 858-633-9123 or ddaniels(äsimplexqrinnelI.com 4/11/2017 REV.#: 0 PROJECT #: SimplexGrinnell LP S:mplexGrinnell BE SAFE 3568 Ruffin Road San Diego, CA 92123-2597 Tele: (858) 633-9100 A Tyco International Company Fax: (858) 633-9101 W www.simpIexgrinneII.com Fire Alarm System Products Model No. Description C.S.F.M. No. 4100-9311 Fire alarm control panel 7165-0026:0251 4100-0622 Digital Audio Riser Module 7165-0026:0251 4100-1329 100 watt Digital amplifier 7165-0026:0251 4100-5311 Enhanced Power Supply 7165-0026:0251 4100-5325 Enhanced Power Supply w/ldNet 7165-0026:0251 4100-1311 Audio Control Board 7165-0026:0251 4100-1241 8 minute message expansion board 7165-0026:0251 4100-6056 Network Wired Media Card 7165-0026:0251 4100-6078 Network Interlace Card 7165-0026:0251 2975-9446 Platinum backbox and glass door 7165-0026:0251 4100-9342 Network Display Unit 7165-0026:0251 4100-1255 3-8 Channel Audio Operator Interface 7165-0026:0251 4100-1240 Auxiliary Audio Input Board 7165-0026:0251 4100-1241 8 minute message expansion board 7165-0026:0251 4100-0622 Digital Audio Riser Module 7165-0026:0251 4100-0623 Basic Network Transponder Interlace 7165-0026:0251 4100-1288 -- 64/64 LED/switch controller 7165-0026:0251 4100-1289 Expansion 64/64 LED/SW Module 7165-0026:0251 4100-1287 24 Switch, 24 Red LED Module 7165-0026:0251 4100-6056 Network Wired Media Card 7165-0026:0251 2975-9446 Platinum backbox and glass door 7165-0026:0251 2081-9296 50AH rechargeable battery N/A 4099-9004 Pull Station 7150-0026:0224 4098-9714 Smoke sensor 7272-0026:0218 4098-9733 Heat sensor 7270-0026:0216 4098-9792 Sensor base 7300-0026:0217 4098-9019 Addressable Beam Detector and Controller 7260-0026:0377 4090-9001 Supervised lAM 7300-0026:0223 4090-9002 Relay lAM 7300-0026:0223 4090-9010 Relay lAM, 8A 7300-0026:0311 4090-9116 Isolator Module 7300-0026:0252 4098-9750 Addressable In-Duct Detector 3240-0026:0220 4098-9755 Addressable Duct Detector 3240-0026:0241 2098-9806 Remote Test Station 7300-0026:0150 2088-9021 PAM-1 Encapsulated interposing relay 7300-1004:0101 49VO-WNF Addressable Strobe multi-CD wall mount 7125-0026:0373 495V-APPLW Addressable Speaker-Strobe multi-CD wall mount 7125-0026:0384 49SV-APPLC Addressable Speaker-Strobe multi-CD ceiling mount 7125-0026:0384 49S0-APPLW Addressable Speaker wall mount 7125-0026:0384 4950-APPLC Addressable Speaker ceiling mount 7125-0026:0384 TX-70A Audio Input Transformer Interlace N/A S5U00625 Document Storage Box N/A 4 4/11/2017 REV.#: 0 PROJECT #: I S 5SimpIEx UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* Il1!l (4.1 Master Controller (top) bay standard equipment: 32-Bit Master Controller with color-coded operator interface and raised switches for high confidence feedback Dual configuration program CPU, convenient service port access, and capacity for up to 2500 addressable points CPU assembly includes 2 GB dedicated compact flash memory for on-site system programming and information storage An Enhanced Power Supply (EPS) and battery charger (9 A output) with on-board: IDNAC SLCs (signaling line circuit) for addressable appliance control, an IDNet 2 Module for addressable device control; and programmable function auxiliary output Also available with InfoAlarm Command Center expanded content user interface (see data sheet S4100-0045) Standard addressable device interfaces include: 250 point addressable device IDNet 2 SLC that supports TrueAlarm analog sensors and IDNet communications monitoring and control devices with an electrically isolated output channel allowing use with either shielded or unshielded, twisted or untwisted single pair wiring; and providing dual short circuit isolating output loops MThTPLEX Transponder and remote LCD and LED annunciator support via RUT+ (remote unit interface) communications port with electrically isolated output for use with either shielded or unshielded, twisted or untwisted single pair wiring (refer to details on page 6) Standard power supplies (EPS) provide enhanced power delivery IDNAC SLCs to addressable notification appliances: With IDNAC SLCs, a constant 29 VDC source voltage is maintained during alarm, even during battery operation, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby Efficiencies include lower strobe currents, wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, and the ability to use smaller gauge wiring - all providing installation and maintenance savings with-high assurance that appliances that operate during normal system testing will also operate during worst case alarm conditions IDNAC SLCs are compatible with both TrueAlert ES and TrueAlert addressable notification appliances, and remote 4009 IDNAC Repeaters to extend power and wiring distance even farther Optional modules and connections include: Fire Alarm Network Interfaces, city connections, and up to five (5) RS-232 ports for printers and terminals Building Network Interface Module (BNIC) for Ethernet connectivity options (see data sheet S4100-0061) Side mounted DACT assembly requiring minimal panel space; DACT is compatible with EP Communicators Emergency communications systems (ECS) equipment; 8 channel digital audio or 2 channel analog audio 4I00ES Fire Control Panels Addressable Fire Detection and Control Basic Panel Modules and Accessories 4100ES Cabinets are Available with One, Two or Three Bays Option Modules (Continued) Additional IDNet 2 communications SLCs, IDNet 2+2 Modules with quad short circuit isolating output loops; additional power supplies, alarm relays, and auxiliary relays LED/switch modules and panel mount printers; VESDA Air Aspiration Systems interface, ASHRAE BACnet Interface, TCP/IP Bridges Battery brackets for seismic area protection (see page 2) 4100ES compatible legacy interface modules, including control of conventional (non-addressable) NACS (see data sheet reference list on page 12) 4I00ES Listings reference: UIL 864, Fire Detection and Control (UOJZ), and Smoke Control Service (UTJKL) UL 2017, Process Management Equipment (QVAX) UL 1076, Proprietary Alarm Units-Burglar (APOU) UL 1730, Smoke Detector Monitor (UTJLH) UL 2572, Mass Notification Systems (PGWIM); refer to data sheet S4100-0034 for audio equipment ULC S527, Control Units for Fire Alarm Systems FkYT1zHI CPU provides dual configuration programs: Two programs allow for optimal system protection and commissioning efficiency with one active program and one reserve; downtime is reduced because the system stays running during download PC based programmer features: Convenient front panel accessed Ethernet port for quick and easy download of site-specific programming Modifications can be uploaded as well as downloaded for greater service flexibility; AND, firmware enhancements are made via software downloads to the on-board flash memory * See pages 6 and 7 for product that is UL or ULC listed and additional listing information. This product has been listed by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:0251 for allowable values and/or conditions concerning material presented in this document. NYC Fire Dept COA #6151. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products, S4100-0100-13 1/2016 Master Controller Bay Optional 4190-6104 Truelnsight Module mounting location EPS Power Supply with IDNet 2 Module Fn ER II -- Expansion Bay 1 Typical bays with mixed module sizes - Expansion Bay 2 Battery Compartment 4100ES Module Placement Reference in 3-Bay Cabinet 4100-6080 DACT mounting location P01 board with two connectors available (Master controller with I dual slot motherboard in, 41 DOES Series Fire Detection and Control Panels provide extensive installation, operator, and service features with point and module capacities suitable for a wide range of system applications. An on-board Ethernet port provides fast external system communications to expedite installation and service activity. Dedicated compact flash memory archiving provides secure on-site system information storage of electronic job configuration files to meet NFPA 72 (National Fire Alarm and Signaling Code) requirements. Modular design. A wide variety of functional modules are available to meet specific system requirements. Selections allow panels to be configured for either Stand-Alone or Networked fire control operation. 77mmr:tI Ir.i i1f1 The Master Controller Bay (top) includes a standard multi-featured enhanced power supply (EPS) with IDNet 2 Module, the master controller board, two vertical expansion blocks, and operator interface equipment. The Expansion Bays include a Power Distribution Interface (PDI) for connection of single or multiple block modules, and/or slot style (motherboard/daughter card) modules. The Battery Compartment (bottom) accepts two batteries, up to 50 Ali, to be mounted within the cabinet without interfering with module space. I1'F1i1tI0i*. il1tri Boxes can be close-nippled; each box provides convenient stud markers for drywall thickness and nail-hole knockouts for quicker mounting Smooth box surfaces are provided for locally cutting conduit entrance holes exactly where required Cabinet assembly design has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F, requires 4100-7912 option for additional legacy card stabilizer brackets and battery brackets as detailed on data sheet S2081-0019 The latching front panel assembly easily lifts off for internal access Modules are power-limited (except as noted, such as relay modules) The NEMA 1/IP30 box is ordered separately and available for early installation Doors are available with tempered glass inserts or solid; boxes and doors are available in platinum or red Boxes and door/retainer assemblies are ordered separately per system requirements; refer to data sheet S4100-0037 L1.Nil11rnflWTi The following illustration identifies the primary functions of the operator interface. Operator interface panel is directly viewable and accessible (no access door) Upload/Download Basic operator instructions Panel sounder Ethernet port access are printed on the interface (under sliding cover) mounting plate "Install Mode" allows grouping of multiple troubles for uninstalled modules and devices into a single trouble condition (typical with future phased expansion); with future equipment and devices grouped into a single trouble, operators can more clearly identify events from the commissioned and occupied areas Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring "Recurring Trouble Filtering" allows the panel to recognize, process, and log recurring intermittent troubles (such as external wiring ground faults), but only sends a single outbound system trouble to avoid nuisance communications WALKTEST silent or audible system test performs an automatic self-resetting test cycle Support for TrueAlarm individual analog sensing and IDNAC addressable notification with front panel information and selection access S4100-0100-13 1/2016 I* Dnrtr Convenient Status Information. With the locking door closed, the glass window allows viewing of the display, status LEDs, and available operator switches. Features include a two-line by 40-character, wide viewing angle (super-twist) LCD with status LEDs and switches as shown in the illustration below. LED indicators describe the general category of activity being displayed with the LCD providing more detail. For the authorized user, unlocking the door provides access to the control switches and allows further inquiry by scrolling the display for additional detail. MMIFIVIMGIIMFIITI I(* Convenient and extensive operator information is provided using a logical, menu-driven display Multiple automatic and manual diagnostics for maintenance reduction Alarm and Trouble History Logs (up to 1250 entries for each, 2500 total events) are available for viewing from the LCD, or capable of being printed to a connected printer, or downloaded to a service computer Convenient PC programmer label editing Password access control FIRE ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts SIX SYSTEM STATUS INDICATOR LEDs PRIORITY 2 ACK acknowledges a Priority 2 Alarm provide system status indications in addition condition, logs the acknowledge, and silences the to LCD information, LEDs flash to indicate the operator panel and all annunciator tone-alerts IULC SYSTEMS condition and then when acknowledged, SUPV ACK acknowledges system supervisory require designating remain on until reset: a Ground Fault Fire Alarm & Priority 2 Alarm, red LED L conditions, logs the acknowledge, and silences the indicator Supervisory & Trouble, yellow LED operator panel and all annunciator tone-alerts Alarm Silenced, yellow LED TROUBLE ACK acknowledges system troubles, logs AC Power, green LED (on for normal) / the acknowledge, and silences the operator panel and all annunciator tone-alerts THREE PROGRAMMABLE LEDs 1 ALARM SILENCE causes audible and visible custom labeling, the top I 12 X 40 LCD READOUT, LED backlighted notification appliances to be silenced (default operation, [Provide two LEDs are selectable as red or during normal conditions and abnormal may be modified through panel programming for yellow, the bottom LED is S j/ operating conditions, provides up to 40 compliance with local requirements) selectable as green or yellow characters for custom label information SYSTEM RESET restores control panel to normal when ion can I [çtorn label insert) / FIRST ALARM DISPLAY: Operation be selected for maintained display of first all alarmed inputs are returned to normal alarm until acknowledged I RMAL I 1IfWflfUJIIld '- THU 24-OCT- 15 12.25 15 am A.0 • - I FeeAl_rr,,Prorty2Aierrr SuperveorTrouble - __ seuu ' ArZ __ Z. A. :•;• Elevat Recall NL Latch I FIVE PROGRAMMABLE I POINT STATUS I ADDITIONAL FUNCTION I I LCD NAVIGATION 1 I NUMERIC KEYPAD for I FUNCTION SWITCHES I CONTROL KEYS: I KEYS: I CONTROL: I [Point categoryandpoint indicator I I each with a yellow LED J Point Enable and I Event Time Request j Menu selection selection (alphabet Disable More Information Request Vertical and characters are not used at Force On or Arm Lamp Test Horizontal position thistime) Force Off or Disarm selection buttons Return On/Off or . Armf Disarm to Auto Mode 3 S4100-0100-13 1/2016 IDNet Addressable Device and IDNAC Addressable Notification Appliance Control Overview. The 4100ES EPS power supply with IDNet 2 Module provides addressable initiating device and IDNAC addressable notification appliance Signaling Line Circuits (SLCs) that supervise wiring connections and the individual device/appliance communications status on their SLC. With these 2-wire SLCs, initiation, monitoring, and control devices such as manual fire alarm stations, TrueAlarm sensors, control relays, and sprinkler waterfiow switches; and notification appliances such as strobes and horns can communicate their identity and status and receive fire alarm system control. Additional interface modules include circuit isolators, conventional DC zone adapters, and interface to other system circuits such as fans, dampers, and elevator controls. Each addressable device on an IDNet communication channel is continuously interrogated for status condition such as: normal, off-normal, alarm, supervisory, or trouble. Both Class B and Class A operation is available. Sophisticated poll and response communication techniques ensure supervision integrity and allow for "T-tapping" of the circuits for Class B operation. Devices with LEDs pulse the LED to indicate receipt of a communications poll and can be turned on steady from the panel. With addressable devices, the location and status of the connected device is monitored and logged, and displayed on the operator interface LCD and on remote system annunciators with each device having its own 40 character custom label for precise identification. kiTii 1 wX.1 Addressable initiating device communications include operation of TrueAlarm smoke and temperature sensors. Smoke sensors transmit an output value based on their smoke chamber condition and the CPU maintains a current value, peak value, and an average value for each sensor. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. TrueAlarm Addressable Sensor Reference TrueAlarm Photo TrueAlarm Photo/Heat Sensor with Base I Sensor in CO Base Programmable sensitivity of each sensor can be selected at the control panel for different levels of smoke obscuration (shown directly in percent) or for specific heat detection levels. To evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read (or downloaded as a report) and compared to the alarm threshold directly in percent. CO sensor bases combine an electrolytic CO sensing module with a TrueAlarm analog sensor to provide a single multiple sensing assembly using one system address. The CO sensor can be enabled/disabled, used in LED/Switch modes and custom control, and can be made public for communication across a fire alarm Network. (refer to data sheet S4098-0052 for details) TrueAlarm neat sensors can be selected tor lixea temperature detection, with or without rate-of-rise detection. Utility temperature sensing is also available, is typically to provide freeze warnings or alert to HVAC system problems. Readings can selected as either Fahrenheit or Celsius. TrueSense Early Fire Detection. Multi-sensor 4098-9754 provides photoelectric and heat sensor data using a single 4100ES IDNet address. The panel evaluates smoke activity, heat activity, and their combination, to provide TrueSense early detection. For more details on this operation, refer to data sheet S4098-0024. Sensor Status. TrueAlarm operation allows the control panel to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72 requirement for a test of the sensitivity range of the sensors is fulfilled by the ability of TrueAlarm operation to maintain the sensitivity level of each sensor. CO Sensors track their 10 year active life status providing indicators to assist with service planning. Indicators occur at: 1 year, 6 months, and end of life. Modular TrueAlarm sensors use the same base and different sensor types (smoke or heat sensor) and can be easily interchanged to meet specific location requirements. This allows intentional sensor substitution during building construction when conditions are temporarily dusty. Instead of covering smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. The control panel will indicate an incorrect sensor type, but the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. 1I0177yr nmnnr.i'irrvnryu :r.i IDNet Addressable Channel Capacity. The CPU bay standard power supply (EPS) provides an IDNet 2 Module providing a signaling line circuit (SLC) that supports up to 250 addressable monitor and control points intermixed on the same pair of wires. IDNet 2 and IDNet 2+2 Module SLCs are isolated from other system reference voltages to reduce common mode noise interaction with adjacent system wiring. Additional 250 address IDNet 2 or IDNet 2+2 Modules are available. IDNet 2 and IDNet 2+2 SLC Wiring Specifications Maximum Distance 1 t 125 4000 ft (1219 m); 50 ohms from Control Panel 2500 feet (762 m); 35 ohms per Device Load 126-250 Total Wire Length Allowed With Up to 12,500 ft (3.8 km); "T" Taps for Class B Wiring 0.60 hF Maximum Capacitance Between liE IDNet 2 Channels Loading per device 0.8 mA supv., 1 mA alarm; 2 mA per activated device LED Wire Type and Connections Shielded or unshielded, twisted or untwisted wire Connections Terminals for 18 to 12 AWG (0.82 mm2 to 3.31 mm2) IDNet 2 and IDNet 2+2 Module Compatibility: IDNet communicating devices and TrueAlarm sensors including QuickConnect and QuickConnect2 sensors * Some applications may require shielded wiring. Review your system with your local Simplex product supplier. S S4100-0100-13 1/2016 I 1010 ETON 11[910 Me, Me i r-iriii S Addressable notification appliance communications problem. Using the TrueAlert magnet test allows each appliance include operation of TrueAlert and TrueAlert ES Visible only to individually identify its candela setting and address and to (yb, strobe), Audible only (A/U, horn), Audible/Visible (A/V, briefly operate if desired, and using the TrueAlert ES horn/strobe), and strobes of Speaker/Visible (SN) notification Appliance Self-Test feature provides detailed performance appliances. (SN appliances require separate speaker wiring.) verification per appliance. IDNAC SLC addressable communications allow each horn and strobe to be individually controlled using a single two-wire S circuit, confirms the wiring connections to the individual notification appliance's electronic circuit, and confirms communications between each appliance and the fire alarm control panel. Addressable communications increases supervision integrity versus conventional notification systems by providing supervision beyond the circuit wiring to each individual appliance and by constantly verifying the ability of each appliance to communicate with the control panel. Individual Appliance Status and Settings. The fire alarm control panel monitors and records each addressable notification appliance status, type of appliance, and its configured appliance settings. A fault in any individual appliance automatically reports a trouble condition to the control panel. TrueAlert ES Addressable Appliance Reference E '[;t NO (horn) V/O (strobe) AN (horn/strobe) Virtual NACs Provide Control Convenience. For control convenience, IDNAC notification appliances can be grouped into Virtual NACS (VNACs) for group control, grouping that can be made across SLCs, not defined by their wiring connection. Panel Control Convenience. Applicable operation settings for each appliance can be programmed without having to replace appliances or remove them from the wall or ceiling. An appliance's VNAC notification zone can be easily changed through programming without having to add additional circuits, conduit, and wiring. Audible and visible appliances for non-Fire Emergency Communications notification can be programmed to operate separately on the same pair ofwires as the fire alarm notification appliances. The result is lower installation, retrofit, and overall life-cycle cost of ownership compared with traditional conventional notification systems. Installation, Retrofit, and Life-Cycle Cost Benefits. With each addressable appliance capable of being controlled separately on the same two-wire IDNAC SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T-tapped" allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Location Information, Diagnostics and Troubleshooting. Each addressable notification appliance has its own 40 character custom label to identify the location of the appliance and to aid in troubleshooting fault conditions. In conventional notification systems, conventional appliances are not capable of communicating with the control panel. Fault reporting on a conventional system is limited to the circuit wiring and the entire area (zone) covered by appliances on the notification appliance circuit (NAC) making it much more difficult and costly to locate and correct the source of a On-Board Test Sensors. TrueAlert ES appliances are equipped with on-board sensors to detect strobe and/or horn output allowing efficient and unobtrusive Self-Testing. When Automatic Self-Test is initiated from the control panel, each appliance within the selected VNAC group will briefly operate and then report its Self-Test status to the control panel, all within several seconds. Silent Self-Test can be selected to test only visible appliance if desired. The control panel is in a trouble condition during testing and in the event of an alarm, Self-Test is automatically terminated. Additionally, Automatic Self-Test can be scheduled to occur at a convenient time on a regular basis. (Requires version 2.03.01 or higher software.) Automatic Self-Test results are communicated to the control panel with a time and date stamp and are stored in memory. Results are viewable at the front panel display and printed reports can be generated from the panel service port. (See sample reports on page 11.) Individual Self-Test is selected from the control panel when individual appliances need to be observed to operate. Each appliance in the selected VNAC group will turn on its LED until individually activated by applying a magnet. After performing the individual test, the appliance LED turns off to indicate completion. Results are recorded the same as during the automatic test. EPS Power Supplies provide three, 3 A IDNAC SLCs for control and power to TrueAlert ES and TrueAlert addressable notification appliances. Both power supplies incorporate an efficient switching design that provides a regulated output of 29 VDC, even during battery operation. With 29 VDC minimum output at the panel, addressable notification SLCs can support wiring distances 2 to 3 times farther than available with conventional notification, or support more appliances per SLC, or work with smaller gauge wiring, or combinations of these benefits, all resulting in installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. ii. IDNAC SLC Capacity: Up to 127 addresses and up to 139 unit loads (appliances are typically one unit load, devices such as Isolators may require more than one load, refer to individual device data sheet for specific information) Recommended wire type UTP, unshielded twisted pair Maximum wire length allowed with "T-Taps" for 10,000 ft (3048 m) Class wiring, _B_ _per _SLC Maximum wire length per 4000 ft (1219 m) SLC _to_ any _appliance Appliance Supervisory 1 unit load = 0.8 mA per appliance Current Wiring connections Terminals for 1810 12 AWG (0.82 mm to 3.31 mm2) Installation Instructions (see 579-1015 for more information) S4100-0100-13 1/2016 Mounts in Slot 2 of a two slot motherboard and provides EPS with IDNet 2 Module Details (Continued): one Class B or Class A, RUI+ isolated communications • DCAl (Dual Class A IDNAC Isolator) Module creates channel with earth fault detection S RUI+ isolated communications controls up to 31 remote devices per master controller at up to 2500 ft (762 m) for single run, or 10,000 ft (3048 m) total if wiring is Class B and T-tapped; if more distance is required, up to four total RUT channels are supported; add up to three 4100-1291 RUT Expansion Modules (4100-1291 provides unisolated RUT communications) Compatible RUI+ remote equipment includes: MINIPLEX transponders, 4603-9101 LCD Annunciators, and 4100 Series 24 I/O and LED/Switch modules RUT Expansion Module 4100-1291 is also compatible with the RUI+ remote equipment listed above; and is required for control of 4602 Series LED/Switch and 110 Annunciator modules, including 4602-9101 Status Command Units (SCU), and 4602-9102 Remote Command Units (RCU); (refer to data sheet S4602-0001) Open slot space on the left of the CPU motherboard is available for either another dual slot motherboard, or for one or two block modules (refer to diagram on page 2) Slot 1 of the motherboard is primarily for the 4100-6078 Network Interface Board with media modules EPS (Enhanced Power Supply) with IDNet 2 Module Details: (see page 9 for specifications) Rating is 9 A output with "Special Application" appliances Outputs are power-limited, except for the battery charger Provides system power, battery charging, auxiliary power, earth detection, on-board electrically isolated IDNet 2 Module with 250 point SLC, three on-board 3 A IDNAC SLCs, and provisions for either an optional City Connect Module or an optional AlarmlSupv/Tbl Relay Module IDNet 2 Module SLC Output provides Class B or Class A communications for up to 250 addressable devices with dual short circuit isolating loop outputs (see details on page 4) Note: The "IDNet 2 Module" replaced the "IDNet 1+ Module" and the term "EPS with IDNet 2 Module" replaces the term "EPS+" two uiass i- outputs irom one IVINI-tL SLC Oass o Input; up to two can be connected to one IDNAC SLC, with up to 6 total per EPS; total Class A output loop current is limited to the 3 A rating of the IDNAC SLC Battery Charger is dual rate, temperature compensated, and charges up to 50 Ah sealed lead-acid batteries mounted in the battery compartment (33 Ah for single bay cabinets); also is UL listed for charging up to 115 Ah batteries mounted in an external cabinet (see data sheet S2081-0012 for details) Battery and Charger Monitoring includes battery charger status and low or depleted battery conditions; status information provided to the master controller includes analog values for: battery voltage, charger voltage and current, actual system voltage and current, and individual IDNAC SLC currents Low Battery Cutout is selectable for each EPS power supply, Canadian models are shipped selected, other models are shipped unselected 2 A Programmable Output: Select for conventional non-synchronous NAC operation to provide supervised reverse polarity for sounder base power, Suppression Release Peripheral (SRP) power, or other coded NAC operation requirements Select for Auxiliary (AUX) operation for sounder base power, 4-wire detector power, or door holder; supervised ATJX operation does not require an end-of- line relay to provide Power-Limited operation EPS Mounted Optional Modules (select one): City Connect Module (4100-6031, with disconnect switches, or 4100-6032, without disconnect switches) can be selected for conventional dual circuit city connections Alarm Relay Module (4100-6033) provides three Form C relays that are used for Alarm, Trouble, and Supervisory, rated 2 A resistive @ 32 VDC S IiYJFMMXG MM Me I r!1rnc.]n,11IrT1 Master Controller and Expansion Bay Selection Model Model Type and Listing Description Current 4100-9311 120 VAC, 50/60 Hz Input UL 4100ES Master Controller Assembly with LCD - display, operator interlace and RUI+ isolated output ULC communications interface; 9 A EPS (Enhanced 4100-9312 English French 1120 VAC, 50/60 Hz Canadian 4100-9313 - Power Supply) with battery charger, electrically isolated 250 point IDNet 2 Module, three Class B Without IDNet devices: IDNAC SLCs, one 2 A output configurable for Supervisory = 425 mA 4100-9511 220-240 VAC, 50/60 Hz Input UL Auxiliary Power or Simple NAC operation and Alarm = 735 mA expansion slot for City Circuit or AlamilSupv/Tbl Relay option Note: Master Controller current does not subtract from 9 A output rating 4100-9331 120 VAC, 50/60 Hz input UL 4100E5 Master Controller Assembly; same as ULC above models except without LCD Display and Operator Interface 4100-9332 120 VAC, 50/60 Hz input, Canadian, English - 4100-2300 Expansion Bay Assembly; order for each required expansion bay 4100-2303 Slot Module Stabilizer Bracket, used when expansion bays have style modules (Continued on next page) 6 S4100-0100-13 1/2016 S Module Selection Information Communication Modules Model 4100-6078 Description For Master Controller; mounts in Slot 3 Modular Network Interface; each requires Far Redundant Master Controller two media modules (below) Size 1 Slot Supv. 46 mA Alarm 46 mA 4100-6061 1 Slot 46 mA 46 mA 4100-6056 Wired Media Module Select two media cards as required; mounts on Fiber Optic Media Module 4100-6078 or 4100-6061; Class B or Class X operation N.A. 55 mA 55 mA 4100-6057 N.A. 25 mA 25 mA 4100-6047 Building Network Interface Card (BNIC), refer to data sheet S4100-0061 for details 2 Blocks 291 mA 291 mA 4100-6055 Network Access Dial-in Service Modem, mounts to 4100-6078 or 4100-6061 Network Interface Card, requires telephone line connection N.A. 60 mA 60 mA 4100-1291 Remote Unit Interface Module (RUI, unisolated); up to 3 maximum per control panel 1 Slot 85 mA 85 mA 4100-6031 Select one per EPS (Note: maximum one per panel) City Circuit, with disconnect switches N.A. 20 mA 36 mA 4100-6032 City Circuit module City Circuit w/o disconnect switches N.A. 20 mA 36 mA 4100-6033 Alarm/Supv/TbI Relay, 3 Form C relays, 2 A @ 32 VDC N.A. 15 mA 37 mA 4100-6046 Dual Port RS-232 standard interface (single block) 3 maximum RS-232 Modules per panel 1 Block 60 mA 60 mA 4100-6038 Dual Port RS-232 with 2120 interface (slot module) 1 Slot 132 mA 132 mA 4100-6079 SafeLINC Internet Interface (refer to data sheet S4100-0062 for details) 2 Blocks 145 mA 145 mA 4190-6104 Truelnsight Remote Monitoring Module (refer to data sheet S4100-0063 for details) Side Mt. 62 mA 73 mA 4100-6101 Physical Bridge, Class B, includes 1 modem module and 2 wired modules 1 Slot 210 mA 210 mA 4100-6102 Physical Bridge, Class X, includes 2 modem and 2 wired modules 2 Slots 300 mA 300 mA 4100-6048 VESDA Aspiration System Interface (refer to data sheet S4100-0026 for details) 1 Slot 132 mA 132 mA 4100-6080 DACT, Point or Event Reporting; 1 shipped unless 4100-7908 is selected; 2 max. per system; includes 2, 2080-9047 cables, 14 ft (4.3 m) long, RJ45 plug and spade lugs Side Mt 30 mA 40 mA Additional Enhanced Power Supplies, Expansion Power Supply, and Accessories (for additional non-addressable Power Supplies, refer to data sheet S4100-0031) Model Voltage/Listing Description Size Supv. Alarm 4100-5311 120 VAC UL & Expansion EPS with IDNet 2 Module; 9 A Expansion Power I 225 mA 490 mA ULC Supply (EPS) with battery charger, electrically isolated 250 point IDNet 2 Module, three Class B IDNAC SLCs, one 2 A output 4 Blocks Right configurable for Auxiliary Power or Simple NAC operation, and Side add IDNet device 4100-5313 220-240 VAC UL expansion slot for City Circuit or Alarm/Supv/Tbl Relay option; 120 VAC model has selectable low battery cutout currents separately 4100-5325 120 VAC UL& ULC Enhanced Power Supply (EPS); 9 A EPS, functionally identical to the Expansion EPS except without the IDNet 2 Module 4 Blocks Right 125 mA 220 mA 4100-5327 220-240 VAC UL Side 4100-5101 120 VAC UL Expansion Power Supply (XPS); 9 A output, 3 built-in Class A/B conventional (non-addressable) 3 A NACs that can 120 VAC , • 4100-5103 Canadian ULC also be selected as 2 A auxiliary power output, 2 A separate 2 Blocks 50 mA 50 mA auxiliary power output; without battery charger; Canadian 4100-5102 220-240 VAC UL model has low battery cutout 4100-5115 NAC Expansion Module, 3 NACs, Class A/B, mounts on XPS only N.A. 25 mA 25 mA Dual Class A IDNAC Isolator (DCAI), converts a single Class B IDNAC SLC input to two Class A or two Class B SLC outputs; provides short circuit isolation between 4100-6103 each Class A or B output circuit; connect up to two DCAI Modules per IDNAC SLC 1 Block 8.3 mA 18.5 mA input up to a maximum of 6 DCAI Modules per EPS; each isolated output SLC used requires one IDNAC address; the total current remains controlled by the Class B input source SLC at 3 A maximum 4100-5152 12 VDC Power Option, 2Amaximum 1 Block 1.5Amaximum 4100-0156 8 VDC Converter, required for multiple Physical Bridge Modules, 3 A maximum 1 Block included w/loads 4100-0636 Box Interconnection Harness Kit (non-audio); order one for each close-nippled cabinet 4100-0638 14100 Slot Module Additional 24 VDC Harness; need when 4100 Slot module requirements exceed 2 A from EPS System Option for Seismic Compliance Model I Description 4100-7912 System option for Seismic compliance, provides additional stabilizer brackets required for legacy style cards Module Selection is continued on next page S4100-0100-13 1/2016 Module Selection Information (Continued) Addressable Interface Modules (Note: Total of initiating SLCs per CPU, including VESDA Interface, is .) Model Description Supv. Alarm IDNet 2 Module, 250 point capacity; electrically isolated output with two short no devices 50 mA 60 mA circuit isolating Class B or Class A output loops, 1 block; standard on EPS with 50 devices 90 mA 150 mA 41003109* lDNet2 Module; alarm currents for 50 and above devices includes 20 device 125 devices 150 mA 225 mA LEDs in alarm 250 devices 250 mA 350 mA IDNet 2+2 Module, 250 point capacity; electrically isolated output with four short no devices 50 mA 60 mA 90 mA circuit isolating Class B or Class A output loops, 1 block; mounts in expansion 50 devices 150 mA 41003110* bay or available master controller bay module locations only, not applicable for 125 d devices m 225 A 150 m EPS mounting; alarm currents for 50 and above devices includes 20 device LEDs 250 mA in alarm 250 devices 350 mA IDNet Short Circuit Isolating Loop Output Module; mount up to two on a 4100-3109 module; for use with 41003111* 4100-3109 modules in expansion bays or available master controller bay module locations only; not applicable for mounting on a 4100-3109 mounted on an EPS; this option is for aftermarket field installation only Four Loop IDNet Master Controller; for the Master Controller Assemblies listed on page 6, this option moves the 4100-3112 standard IDNet 2 Module from the Master Controller EPS to an available block space in the master controller bay and adds 2, 4100-3111 IDNet Loop Output Modules; requires selection of Factory Built Option 4100-7905; current requirements remain the same *Note: Loading per IDNet device (no LEDs on) = 0.8 mA supervisory and 1 mA alarm. Each IDNet 2 and IDNet 2+2 Short Circuit Isolating Loop Output can be individually controlled for system diagnostics and can be assigned a public point for Fire Alarm Network annunciation. Relay Modules; Nonpower-limited (for mounting in expansion bay only, refer to location reference on page 10) Model 4100-3202 Description 4 DPDT w/feedback Resistive Ratings 10 A @ 250 VAC Inductive Ratings 10 A @ 250 VAC Size 2 Slots Supv. 15 mA Alarm 175 mA 4100-3204 4 DPDT w/feedback 2 A @ 30 VDCNAC 1/2 A @ 30 VDC/120 VAC 1 Block 15 mA 60 mA 4100-3206 8SPDT 3A@3OVDC/12OVAC 1-1/2A@3OVDC/12OVAC 1 Block 15 mA 190 mA Current Calculation Notes: To determine total supervisory current, add currents of modules in panel to base system value and all external loads powered by panel power supplies. 0 To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel SLC and NAC loads and all external loads powered from panel power supplies. End User Programming Software (requires 4100-8802) Model I Description 4100-8802 Programming Software (select) End User Programming Software Selection (select maximum of one each from below) Model I Description 4100-0292 Custom Labels Editing; allows editing of 40 Character Custom Labels for non-system user points Access Level/Passcode Editing; allows user to re-assign Access Levels and Passcodes for each display function; 4100-0296 Acknowledge, Alarm Silence, System Reset, Point Enable/Disable, WALKTEST Enable/Disable, Clear History Logs, Change Time & Date, etc. 4100-0295 1 Port Vectoring Setup and Control; Allows vectoring of events to PC Annunciator, Printers, LCD Annunciators, etc. WALKTEST Configuration Setup and Control; Allows user to create or edit WALKTEST groups used to test system 4100-0298 initiating devices and signals by a single person, these groups allow an inspector to conduct a one-person WALKTEST in a specific area of a building (or different buildings), and limit the activation of the building signals to only the intended area; up to 8 WALKTEST groups are supported Miscellaneous Accessories Model 4100-1279 Description Single blank 2" display cover; 4100-2302 provides a single plate for a full bay 4100-9835 Termination and Address Label Kit (for module marking); provides additional labels for field installed modules 4100-9856 4100ES Canadian French Appliqué Kit; Simplex, 4100ES, ContrOle Incendie 4100-9868 Special Purpose Appliqué Kit: Simplex, Elevator Recall Control and Supervisory Control Unit, 4100ES 4100-9869 Special Purpose Appliqué Kit: Simplex, Sprinkler Waterfiow and Supervisory Station, 4IOOES 4100-6029 Smoke Management Application Guide; required for UUKL listing 4100-6034 Tamper Switch, one per cabinet assembly if required; monitors solid door for panels with solid door; monitors the internal retainer panel for panels with glass door (not the glass door); has a built-in addressable IDNet lAM - 2081 9031 Series resistor for WSO, lDCs (NO. water flow and tamper on same circuit, wires after water flow and before tamper) 470 0, 1 W, encapsulated, two 18 AWG leads (0.82 mm2 ), 2-1/2" Lx 1-3/8" W 1" H (64 mm x 35 mm x 25 mm) 8 S4100-0100-13 1/2016 C S S General Specifications 120 VAC Models 4.6 A maximum @ 102 to 132 VAC, 50/60 Hz 220-240 VAC Models 2.3 A maximum @ 204 to 264 VAC, 50/60 Hz; Enhanced Power Supplies (EPS) separate taps for 220/230/240 VAC Battery Input Rating 12 A maximum @ 24 VDC (during battery operation) Input Power 120 VAC Models 4 A maximum @ 102 to 132 VAC, 60 Hz Expansion Power Supplies (XPS) 220240 VAC Models 2 A maximum @ 204 to 264 VAC, 50/60 Hz; separate taps for 220/230/240 VAC 9 A output for "Special Application" appliances Total Power Supply Note: The 9 A output rating of the EPS was determined Output Rating such that optional module currents, and external device and appliance currents can be directly added together, not to exceed 9 A total. Output switches to 3 A, regulated 29 VDC during Alarm, 127 addresses, 139 Power Supply Output IDNAC SLC Ratings unit loads; DC-Dc converter circuit is >92% efficient over battery backup Ratings for EPS operating range during mains AC failure or brownout Output terminals are rated for 18 to 12 AWG with duplicate conditions output terminals rated for two wires each, allowing up to IDNAC SLC Wiring four (4) Class B branch circuit T-taps to be made in the cabinet; additional T-taps may be made in external wiring junction cabinets or boxes 2Amaximum, 24 VDC nominal (19.5 to 31.1 VDC) Auxiliary Power Tap Compatible Special Application Appliances Simplex TrueAlert ES and TrueAlert addressable notification appliances; contact your Simplex product representative for compatible appliances Battery Charger Battery capacity range UL listed for battery charging of 6.2 Ah up to 115 Ah (batteries larger than 50 Ah Ratings for EPS require a remote battery cabinet); ULC listed for charging up to 50 Ah batteries (sealed lead-acid Charger characteristics Temperature compensated, dual rate, recharges depleted batteries within 48 batteries) and performance hours per UL Standard 864; to 70% capacity in 12 hours per ULC Standard S527 Including module currents and auxiliary power outputs; Total Power Supply NAC outputs are rated 9 A output for "Special Application" Power Supply Output Ratin g non-addressable appliances; 4 A output for "Regulated 24 Output switches to Output Ratings for DC" power (see details below); 6 A output with each NAC battery backup XPS (nominal 28 VDC selected as auxiliary power output during mains AC on AC; 24 VDC on Auxiliary Power Tap battery backup) failure or brownout conditions 2 A maximum I 2 A maximum per NAC; NACs Programmed for I Rated 19.1 to 31.1 VDC Auxiliary Power 5 A maximum total Special Application I Simplex horns, strobes, and combination horn/strobes and speaker/strobes (contact your Simplex product Appliances representative for compatible appliances) Regulated 24 DC Appliances I I Power for other UL listed appliances; use associated external synchronization modules where required Operating Temperature Environmental 32" to 120°F (0° to 49° C) Operating Humidity Up to 93% RH, non-condensing @ 90° F (32° C) maximum Additional Technical Reference Description Document Description Document ES Installation Instructions 574-848 IDNet 2 and 2+2 Module Installation Instructions 579-1169 ES Operating Instructions 579-197 EPS Installation Instructions 579-1015 DCAI Module Installation Instructions 579-1029 S4100-0100-13 1/2016 uIis - Slot Slot Slot Slot slot Slot Slot Slot Block A Block C Block E Block 0 Size Definitions: 1 Block = 4" W 5.65" H (102 mm x 144 mm); (often called 4 x 5 modules) 1 Slot =2"Wx11.3"H(51 mm x 287 mm), typically a motherboard with daughter card Block B Block D Block F Block H I Expansion Bay Chassis I Mounting and CPU Bay Module Reference (* indicates supplied modules) / One 2" card: either 4100-6078 Network Module with media cards or 4100-6038 RS-232/2120 Interface Master Controller Bay Space for two 2' slot modules, or one 4' slot modules, or two single block modules, or one double block (vertical mount) module Optional 4100-6049 Truelnsight Module mounting location Typical Expansion Bay (showing mixed module sizes) Two bay cabinet shown without dress oanel Battery Compartment (50 Ah maximum) 4100-6030 Service Modem mounts only on master controller board 4100-6031 or 4100-6032 ______ City Circuit or 4100-6033 Relay Module mounts on bottom of EPS 4 4100-6080 DACT mounting location Exposed cabinet for "EPS power supply with IDNet 2 module semi-flush mounting r .. "Master controlle 1/2" (12.7 mm) with motherboard minimum > Door 4-3/4" (121 mm) Knockout 1 Cabinet height: S screw/nail I (2 bay shown holes (for for reference) semi-flush I I Bay = 22" mounting) J (559 mm) 2 Bay = 40" I (1016 mm) 3 Bay = 56" I (1422 mm) Wall board reference for semi-flush mounting, 6" stud alignment markers, each side 6" studi I Door can be hung'- "I hinged left or rf 4 24" (610 mm) 6-29/32" / (175 mm) [Optional semi-flush trim kit) 1111/16"______ (296 mm) NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. 10 S4100-0100-13 1/2016 S S TrueAlert ES Appliance Self-Test Last Test Results Report Example Service Port Page 1 REPORT 10 TrueAiertES Self-Test Report 12:34:56pm WED 03-DEC-14 Point ID Custom Label Date Visual Audible Ti-i-1 VO FIRST FLOOR (up to 40 characters) 03-DEC-14 NO OUT N/A Ti-2-5 AV FIRST FLOOR EAST WING 03-DEC-14 NO OUT NORMAL T7-3-55 AD SECOND FLOOR EAST WING 03-DEC-14 N/A NO OUT T8-2-45 AV SECOND FLOOR ROOM 29 03-DEC-14 NOT TST N/A T8-2-60 AV SECOND FLOOR ROOM 22 03-DEC-14 NORMAL NORMAL Ti-2-4 AD FIRST FLOOR ROOM 17 03-DEC-14 N/A UNSUPP TRUEALERTES SELF-TEST REPORT COMPLETED Press RETURN for next Screen OR CTRL-X to abort Results Description: NORMAL = works correctly NO OUT = No Output, no light or sound was detected NOT TST = no result; either the appliance did not return a result before the test ended or the test was conducted as silent (strobes only) and audible appliance was not activated N/A = not applicable (no strobe on audible only, etc.) UNSUPP = appliance not compatible with Self-Test (TrueAlert addressable appliance not TrueAlert ES addressable appliance) Note: Additional TrueAlert ES Self-Test information is detailed in ES Operating Instructions 579-197 shipped with the panel. TrueAlert ES Appliance Self-Test All Test Results Report Example Service Port REPORT 10 TrueAlertES Self-Test Report 12:34:56pm Page 1 WED 03-DEC-14 Point ID Custom Label Date Visual Audible Ti-i-i VO FIRST FLOOR 03-DEC-14 NO OUT N/A Ti-2-5 AV FIRST FLOOR EAST WING 03-DEC-14 NO OUT NORMAL T1-2-6 AV FIRST FLOOR NORTH ENTRANCE 30-OCT-14 NO OUT NORMAL T7-3-55 AD SECOND FLOOR EAST WING 03-DEC-14 N/A NO OUT T8-2-45 AV SECOND FLOOR ROOM 29 03-DEC-14 NOT TST N/A Ti-i-il AV FIRST FLOOR SOUTH ENTRANCE 30-OCT-14 NORMAL NORMAL T8-2-60 AV SECOND FLOOR ROOM 22 03-DEC-14 NORMAL NORMAL Tl-2-4 AD FIRST FLOOR ROOM 17 03-DEC-14 N/A UNSUPP Tl-2-7 AD FIRST FLOOR ROOM 12 30-OCT-14 N/A UNSUPP T8-3-43 AV SECOND FLOOR ROOM 25 30-OCT-14 UNSUPP UNSUPP TRUEALERTES SELF-TEST REPORT COMPLETED Press RETURN for next Screen DR CTRL-X to abort TrueAlert ES Appliance Self-Test Individual Appliance Report Example CUSTOM LABEL 4-1-2 POINT ADDRESS: 4-1-2 CARD: 4 CHANNEL: 1 DEVICE: 2 EXTENDED POWER SUPPLY UNIT NUMBER: 2 AV Type: AV RUI NUMBER: LOCAL PRIMARY STATUS NORMAL AUDIBLE GROUP CONFIG: 000 VISUAL GROUP CONFIG: 000 STYLE: INDOOR OPERATION: GENERAL EVAC CANDELA RATING 15CD COLOR LENS YES TONE TYPE BROADBAND CODING TYPE TEMPORAL VOLUME HIGH LAST TEST TIME: MONO2-JUN-14 01:00 AM LAST VISUAL TEST: NORMAL LAST AUDIBLE TEST: NORMAL LAST TEST VOLUME: NORMAL DEVICE TEST TROUBLE: NORMAL II S4100-0100-13 1/2016 Additional 4100ES Data Sheet and Related Product Reference S Subject Introducing the 41 ODES Data Sheet S4100-0060 Subject Fire Alarm Network Overview Data Sheet S4100-0055 4100ES Enclosures S4100-0037 Network Communications S4100-0056 4100ES Audio and Firefighter Phone Modules 54100-0034 Network Display Unit (NDU) S4100-0102 LED/Switch Modules & Printer S4100-0032 Addressable Device Compatibility S4090-0011 Remote Annunciators S4100-0038 4009 IDNAC Repeater S4009-0004 MINIPLEX Transponders S4100-0103 Remote Battery Charger 54081-0002 Building Network Interface (BNIC) S4100-0061 SafeLINC Internet Interface S4100-0062 lnfoAlarm Command Center S4100-0101 4100ES Panels for Conventional Notification 54100-0031 Graphic I/O Modules S4100-0005 TrueAlarm Sensors S4098-0019 lruelnsight Remote Service S4100-0063 Remote IDNet Isolator S4090-0005 Agent Release Applications S4100-0040 TrueAlarm lDNet Isolator Base S4098-0025 TrueAlert ES Audible Only Appliances 549A0-0001 TrueAlert ES Weatherproof Appliances, UL Listed S49WP-0001 TrueAlert ES Visible Only Appliances I S49V0-0001 TrueAlert ES Weatherproof Appliances, ULC Listed S49WP-0002 TrueAlert Appliance/IDNAC SLC Isolator S4905-0001 TrueAlert ES Emergency Communications Appliances with Color Lenses S49LENS - 0001 TrueAlert ES AudibleNisible Appliances S49AV-0001 11 S TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. VESDA is a trademark ofXtralis Pty Lid. NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association (NFPA). ASHRAE and BACne1 are trademarks ofASHRAE, American Society of Heating, Refrigeration, and Air Conditioning Engineers. ®S i rn p1 EX Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4100-0100-13 1/2016 www.simplex-fire.com 02015 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. S £LSim plEx UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* 4I00 Fire Control Panels Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment S Ili!I3-1 Emergency voice/alarm communications provide: Alarm/evacuation signal generation with multiple built-in tones Standard or customized digital message storage and message generation Automatic or manual operation Mass Notification operation Multiple channels are available: Analog audio systems provide dual channel operation Digital audio systems provide up to eight channels over a single wire pair Communications features: Up to five supervised remote microphone inputs Spoken voice coding from the digital message player Multiple digitally recorded human voice messages Spoken WALKTEST system testing Separate evacuation, drill, and optional "All Clear" voice messages and tones Ready-to-talk microphone indicator on front panel audio control module Local panel speaker for tone/message broadcast verification MINIPLEX Voice Transponders are available for distributed audio Amplifiers are available with analog or digital input: Flex-35 (35 W) and Flex-50 (50 W) amplifiers provide a dual channel design with configurable operation modes 100 W primary and backup, single channel amplifiers include a built-in power supply Amplifiers are available for 25 VRMS or 70.7 VRMS output with on-board, power-limited NACs (only one voltage choice per system) Built-in Temporal Pattern horn tone provides default backup signal operation Optional modules provide power-limited NAC expansion, convert Class B NACs to Class A operation, and provide Constant Supervision Operation for Non-Alarm Audio (NAA) applications (NAA requires additional hardware, and software revision 11.08 or higher) Firefighter telephone systems: Master telephone can simultaneously talk with up to 6 remote telephones and can be connected as an audio input for broadcast messages Ring signal on remote firefighter telephone indicates that a call request is initiated and a hold signal indicates that a connected line has been deselected Telephone circuits are supervised for open and short circuits, too many telephones connected, and the master telephone is supervised for cord integrity Degraded mode allows remote telephones to remain connected to each other in the event of a communications loss 4100ES Fire Alarm Control Panel with Voice and Firefighter Telephone Options Listed to: UL Std. 864, Fire Detection and Control (UOJZ), and Smoke Control Service (UTJKL) UL Std. 2017, Process Management Equipment (QVAX) UL Std. 1076, Proprietary Alarm Units-Burglar (APOU) UL Std. 1730, Smoke Detector Monitor (IJUtH) ULC Std. S527-99 Drinfic 4I00ES Audio Systems provide voice communication, alarm tones, and/or digitally prerecorded voice messages to alert occupants of fire or other emergency situations. Evacuation signaling may be automatically generated via alarm initiated event programs or by firefighting personnel using the operator controls. 4100U Series Products Note. The audio system modules and features listed in this data sheet are both compatible with, and listed for use with 4100U series fire alarm control panels. Contact your local Simplex® product supplier for details. * See page 5 for product that is listed as UL or ULC and additional product listing details. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:251 for allowable values and/or conditions concerning material presented in this document Accepted for use - City of New York Department of Buildings-. MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4100-0034-14 6/2013 The Audio Controller Module provides digitized alarm tones and digitally recorded voice messages and message construction, and manages both microphone inputs and other auxiliary inputs connected to the optional Auxiliary Audio Input Module. Tones and voice messages are digitally recorded and stored in the audio control module's message memory. Two versions are available: Analog and Digital. Systems must be either analog or digital, not intermixed. One audio control module controls the entire audio system. Common audio control board features: On-board digital message memory provides up to 2 minutes at normal or 1 minute at high resolution Connects to optional 4-input audio input modules (two maximum) for a total of up to 6 microphones and 11 distinct audio inputs Memory expansion is available to provide up to 8 minutes or 32 minutes at normal resolution (4 minutes or 16 minutes at high resolution) Connections for a Master Microphone and one Remote Microphone, compatible with standard or noise-canceling microphones Master telephone to audio interface connection uses the audio bay's Power Distribution Interface Module (PDi) Local panel speaker output with on-board volume control On-board download port for message loading The microphone ready-to-talk LED is located on the front panel audio control module (see p. 4) and requires connection to a 64 LED/64 switch controller Audio risers, either digital or analog, may be directly connected to 31 remote nodes; for applications requiring audio risers to more than 31 remote nodes, alternate connection methods are available, contact your Simplex product representative for details ri irrnr Analog audio control modules are for systems that require one or two simultaneous channels of audio information per the following feature summary. Built-in 10 VRMS riser output eliminates the need for separate riser amplifiers available as Class B or Class A Messages can play on one or both risers simultaneously, with the same or a different message Analog audio controllers are for connection to analog input audio amplifiers and audio risers only On-board status LEDs assist with setup and troubleshooting mr Digital audio control modules are for systems that require more than two simultaneous channels of audio information per the following feature summary. Up to 8 channels of information at normal resolution are available (4 channels at high resolution) on one twisted wire pair Primary 1 Digital Audio Riser (DAR) output can be either wired Style 4 or Style 7; Primary 2 DAR is an identical, separate output for Style 4 connections, typically to local MThTPLEX voice transponders Digital audio controllers are for connection to digital input audio amplifiers and digital audio risers only rrni iii The Temporal 3 Pattern is available for compatible tones (1/2 sec on, 1/2 sec off, 1/2 sec on, 1/2 sec off, 1/2 sec on, 1-1/2 sec off) to indicate evacuation. The following is a list of the standard audio tones. Horn, continuous 500 Hz tone, primarily used for coded systems or general temporal pattern signaling Chime, a digitally recorded mechanical chime tone, normally used free-running or for coded operation Bell, a digitally recorded mechanical bell sound, normally used free-running, for coded systems, or general temporal pattern signaling Fast Whoop, a quickly ascending tone Slow Whoop, a slowly ascending tone High/Low, with high frequency of 750 Hz for 100 ms and low frequency of 500 Hz for 400 ms Beep, 500 Hz tone of 0.7 s on, 0.7 s off Stutter, 500 Hz tone with on and off times of 100 ms Wail, ascends, then descends between 600 to 940 Hz GSA Tone, continuous 2000 Hz tone 'i*Nif1t1 Zone Coded Signaling is available using tones or spoken numbers. Spoken coded messages can be used in place of conventional pulse tone coding to eliminate counting and interpretation of the zone coded location. For example, a fire alarm zone such as First Floor East, Smoke Detector Room 23 will be Code 1123. Two possible transmission schemes are: Conventional Zone Coded Signaling where T = Tone: T ... T ... TT ... TTT ... T ... T ... TL ... TTT... Spoken Coded Signaling: Code, one., one.. two.. three; Code, one.. one.. two. .three The Audio Controller has the ability to precede spoken codes with phrases and alert tones. As an alternative, the previous example could have been preceded with a chime tone. The word "code" could be replaced with the phrase "Doctor Firestone, please dial...". Preprogrammed Special Messages can be ordered. Up to 32 minutes of special phrases and messages are available to meet specific applications. The standard Evacuation Message is: "Attention... Attention... Attention ... An emergency has been reported... All occupants walk to the nearest stairway exit and walk down to your assigned re-entry floor or main lobby... Do not use the elevator... Walk to the nearest stairway.... Do not use the elevator.... Walk to the nearest stairway." Custom Message Ordering is summarized below: Model Description Select when Custom Messages are required, 4100-8804 choose message types from below as required (minimum ouantitv of one) 4100-0822 Custom Messages from Tape Order (1) 4100-082x for Custom Messages from Transcript; NOTE: Send each (2) complete 4100-0823 transcript in advance to messages without Applications Engineering to spliced phrases; verify phrase quantity or for each (50) spliced phrases Custom Messages from Archive 4100-0824 1 CO Relocation Message; Temporal 4 Pattern horn tone with English male voice instruction; identify as "UCSET1393 when ordering S4100-0034-14 6/2013 S S S S rrr ffeTM TVI1F tflj]j1IP4f, iJ'1It1 41 ODES audio amplifiers are available as dual channel models rated for 35 W (Flex-35) or 50 W (Flex-50) and as single channel 100 W models with on-board NACs (notification appliance circuits) for convenient field wiring. Common features are summarized as follows: Analog input amplifier models are for single or dual channel system operation Digital input amplifier models are for multi-channel system operation providing up to eight channels over a single twisted wire pair Amplifiers are power-limited with models available providing 25 VRMS, or 70.7 \TRMS output When Non-Alarm Audio (NAA) applications (such as for background music, paging, or for Mass Notification) are required, optional Constant Supervision modules provide continued speaker zone supervision during the page or while background music is playing; due to the NAA supervision requirements, amplifiers used for paging or playing background music are derated to 70% of alarm output rating (24.5 W, 35 W, and 70 W) Linear power output stages are traditional Class B designs for low distortion and low EMI An on-board 500 Hz temporal pattern horn tone on each amplifier provides a default backup tone Supervision actively monitors amplifier gain in real time, comparing output level to input level On-board test switches can be activated to test and observe amplifier backup On-board overcurrent protection protects against overloads and short circuits Each amplifier communicates to the host CPU and allows voltage and current values to be accessed from the fire alarm control panel operator interface Flex-35 and Flex-50 amplifiers are a self-backup dual channel design that provides a total of 35 W or 50 W of audio power with the following common feature summary: Self-backup feature allows NACs connected to a disabled amplifier channel to be routed to the remaining channel with the full 35 W or 50 W providing the single channel as selected by the fire alarm control panel programming; external backup amplifiers are not required Three standard on-board audio NACs are each rated for 2 A maximum and are capable of being routed to either desired amplifier channel Compatible power supplies include the: Expansion Power Supply (XPS), Enhanced Power Supply (EPS+ and EPS), Remote Power Supply (RPS), or System Power Supply (SPS); power supplies with single amplifiers can provide power for other compatible applications within their rated output Digital models of the Flex-35 and Flex-SO have a digital decoder module that selects one or two of the input channels as desired Selectable reduced output levels of-12 dB or -6 dB are available for non-emergency audio output, selectable per channel Each Flex-35 channel is capable of up to 35 W output with a total of 35 W Channels can be divided as 0 W and 35 W; 17.5 W and 17.5 W; 10 Wand 25 W; or any combination that totals 35 W or less It.1sLThI1l1dF Each Flex-SO channel is capable of up to 50 W output with a total output of 50 W Channels can be divided as 0 W and 50 W; 25 W and 25 W; 10 W and 40 W; or any combination that totals 50 W or less I .1TflIrcI.tI1 Two Flex-35 amplifiers, or two Flex-SO amplifiers can connect to a single Expansion Power Supply (XPS) in the same audio expansion bay (amplifiers must be the same model number); XPS output is dedicated to amplifier power Mounting for dual Flex-35 or Flex-SO amplifiers is Blocks A & B for amplifier 1, Blocks C & D for the XPS, blocks E & F are not used, and Blocks G & H are for amplifier 2 (see page 7 for mounting reference) I(IIi1'i'IT!ITYT11l1fl 100 W amplifiers provide single channel operation per the following feature summary: Six standard on-board Class B audio NACs are each rated for 2 A maximum 100 W amplifiers include a built-in power supply and use system battery backup Amplifier and power supply size requires four continuous blocks of expansion bay size A single 100W primary amplifier or both a primary and a backup amplifier can be located on a single expansion bay (refer to page 7 for bay loading) Redundant (backup) amplifiers interconnect directly to minimize wiring connections and their power is routed through the NACs of the primary amplifier Redundant amplifier operation can be configured as one-for-one or one-for-many depending on specific requirements Digital models of these amplifiers have a digital decoder module that selects the desired input channel per system requirements Selectable reduced output levels of-12 dB or -6 dB are available for non-emergency audio output For applications requiring additional NACs, modules are available for on-board expansion and further expansion is available with the chassis mounted 4100-5116 Expansion Signal Module 100 W Amplifiers support optional modules that convert the six audio NACs to Class A or to increase the Class B audio NACs to twelve NOTE: Adding NAC expansion modules does not increase amplifier power beyond the stated ratings S4100-0034-14 6/2013 3reen .ED Red I LEDs I Green LEDs 1/ Green LED Red LEDs L Green LEDs Green Green LED LED I Red I Red Visible area r LEDs [LEDS 8-114' H, 2W (210 mm x 51 ml L Green i Green I LEDs LEDs Audio Bay Reference with, Single Channel Audio Control and Firefighter Telephone Modules i ___ii1 DiEi me 11111 • V4 zi M O no z L_ == - I I I I Master Phone 8 Switches with 8 Master Microphone 8 Switches with 8 Red Module 4100-1270 Red LEDs, Module 4100-1243 LEDs, 4100-1280 4100-1280, 2 shown w Single Channel Audio with typical labels Control 4100-1252 Audio Control Modules 4100-1252, 4100-1253, 4100-1254, 4100-1255, Single Channel 1.5 Channel Dual Channel 3-8 Channel Blank switches can be programmed as required 4 S4100-0034-14 6/2013 S S NOTE: Select systems as either analog or digital (refer to pg. 7 for mounting reference and pg. 8 for additional specifications) Analog Emergency Voice/Alarm Communications Equipment, Constant Supervision Compatible Model Description Details 4100-9620 Basic Analog Audio Operation with microphone, requires Includes: Expansion Bay, 4100-1210 Analog Controller Board dedicated expansion bay Microphone Module, and Audio Expansion Bay Kit 4100-1210 Analog Controller Board only; order expansion bay and Controller board mounts in Blocks A and B audio expansion bay kit separately 4100-1361 25 VRMS output Flex-35, 35 WAmplifier, constant 70.07 VRMS output supervision compatible NAC rating = 1.4 A 35W, or 100 NAC rating = 0.5 A speakers max. I Includes three on- I board Class B audio I NACs; power is I supplied from an XPS, EPS, RPS, or SPS* 4100-1362 4100-1312 25 VRMS Output Flex-50, 50 WAmplifler, constant 170.7 VRMS output supervision Compatible NAC rating = 2 A 50W, or 100 NAC rating = 0.707 A speakers max. 4100-1313 100 W Analog Amplifiers with Power Supply, Constant Supervision Compatible Model/Output Voltage 25 VRMS Power Supply Input/Listing 70.7 VRMS Description Details 4100-1314 4100-1315 120 VAC, 60 Hz UL Includes six, Class B audio NACs; Primary 4100-1316 4100-1317 12O VAC, 60Hz ULC 100W NAC rating = 100 speakers maximum; ULC 4100-1318 4100-1319 220/230/240 VAC, 50/60 Hz UL Amplifier 2 A @ 25 VRMS (50 ; models 1.414 A @ 70.7 VRMS (100 W) have 1- 4100-1320 4100-1321 12O VAC, 60Hz UL 4100-1322 4100-1323 120 VAC, 60 Hz ULC 4100-1324 4100-1325 220/230/240 VAC, 50/60 Hz UL Backup battery 100W Uses the six Class B NACs of primary dropout Amplifier amplifier circuit Digital Emergency Voice/Alarm Communications Equipment, Constant Supervision Compatible Model Description Details 4100-9621 Basic Digital Audio Operation with microphone, requires Includes: Expansion Bay, 4100-1311 Digital Controller Board, dedicated expansion bay Microphone Module, and Audio Expansion Bay Kit 4100-1311 Eight Channel Digital Controller Board only; order Controller board mounts in Blocks A and B expansion bay and audio expansion bay kit separately 4100-1363 25 VRMS Output Flex-35, 35W Amplifier, constant 70.07 VRMS output supervision compatible NAC rating = 1.4 A 35 W, or 100 NAC rating = 0.5 A speakers max. I Includes three on- I board Class B audio I NACs; power is supplied from an XPS, I EPS, RPS, or SPS \_4100-1364 \100-1326 125 VRMS Output Flex-50, 50W Amplifier, constant 1 70.7 VRMS output supervision compatible NAC rating = 2 A 50 W, or 100 NAC rating = 0.707 A speakers max. 41'8,0-1327 10W Digital Amplifiers with Power Supply, Constant Supervision Compatible Mode'?&utput Voltage 25 VRMS 70.7 VRMS Power Supply Input/Listing Description Details 4100-1328 4100-1329 120 VAC, 60 Hz UL Primary 100W Amplifier Includes six, Class B audio NACs; NAC rating = 100 speakers maximum; 2 A © 25 VRMS (50 \; 1.414 A @ 70.7 VRMS (100 W) ULC models have low 4100-1330 4100-1331 12O VAC, 60Hz ULC 4100-1332 4100-1333 220/230/240 VAC, 50/60 Hz UL 4100-1334 4100-1335 120 VAC, 60 Hz UL Backup 100W Amplifier Uses the six Class B NACs of primary amplifier battery dropout circuit 4100-1336 4100-1337 12O VAC, 60Hz ULC 4100-1338 4100-1339 220/230/240 VAC, 50/60 Hz I UL Audio Options for use with either Analog or Digital Systems (see page 2 for custom message ordering) Amplifier and Related Audio Options Model Description Details and Mounting Reference Flex-35/50 Expansion NAC Module; adds 4100-1245 Choose Mounts on Flex-35150 assembly; NAC ratings = 1.5 A, 35/50 W, three Class B audio NACs or 100 speakers maximum: Supv. = 8.4 mA, Alarm = 60 mA one per 4100-1246 Flex-35/50 Class A Adapter Module; converts amplifier Mounts on Flex-35/50 assembly; NAC ratings = 2 A, SOW, or three on-board NACS to Class A operation 100 speakers maximum; Supv. = 1 mA, Alarm = 30 mA 4100-1248 100 WAmplifler Expansion NAC Module; NAC Choose Provides six additional Class B audio NACs, mounts on 100W ratings = 1.5 A, 50W, or 100 speakers max. one e ampli pfi r er amplifier assembly; Supv. = 17 mA, Alarm = 60 mA 4100-1249 100W Class A Adapter Module; NAC ratings Converts six on-board NACs to Class A operation, mounts on = 2 A, 50 W, or 100 speakers maximum 100 W amplifier assembly; Supv. = 1 mA, Alarm = 60 mA 25 VRMS Output; NAC Constant Supervision Supv. = 10 mA 4100-1259 rating = 2 A, 50 W, or 100 Adapter for three NACs; on batteries; Converts three Class B audio NACS to Class A speakers maximum select per amplifier output (not compatible with Alarm = 35 mA or Class B Constant Supervision NACs; mounts on Flex-35/50 or 100W amplifier assembly: 70.7 VRMS Output; NAC Supv. = 38 mA 4100-1260 rating = 0.707 A, 50 W, or amplifier NAC expansion Alarm = 70 mA use two for the six NACs on 100 W amplifiers; 100 speakers maximum modules) * Refer to data sheets S4100-0100 (EPS+/EPS) and S4100-0031 (SPS/RPS) for power supply details. (continued on next page) 5 S4100-0034-14 6/2013 Model Description Details 4100-0623 Network Audio Riser Controller Module for Typically for Network nodes without an audio controller, used for NM control of either an analog or digital riser module applications; mounts in Block A; current = 35 mA 4100-0621 Dual Channel Analog Audio Accepts two separate audio signals from host; controlled by Transponder Riser Module Select one, Interface Module: current = 25 mA when active 4100-0622 3-8 Channel Digital Audio Riser Receives and decodes digital inputs; up to eight audio channels; Module; with NAA input mounts in Block B current = 70 mA; NAA input for 25, 70.7, or 0.707 VRMS MCC (Multiple Command Center) Selects a single digital audio channel and converts it to an analog line level 4100-1341 Digital Audio Riser Interface for input to an analog 4100ES/ 4100U/4100 Legacy voice panel; current = 70 mA 4100-9854 4100/4100+ Legacy bay mounting kit Use to mount 4100-1341 MCC Digital Audio Riser Interface in legacy panel 4100-1258 NPU to 4100ES Audio Interconnect Module; Dual terminal block module with harnesses for connecting to the Audio mounts in 4100ES Audio cabinet Controller and Telephone Control module (requires 1 Block) N S Emergency Voice/Alarm Communications Equipment Product Selection (Continued) S Model Description Details and Mounting Reference Expansion Signal Module; three, 1.5 A Class B Converts one NAC input to three NAC outputs; selects between two inputs; 4100-5116 NACs; up to five maximum per amplifier; NAC for Flex-35/50 amplifiers only, two input NACs are required; Single Block rating = 1.5 A, 50W, or 100 speakers maximum module mounts in expansion bay; Supv. = 20 mA; Alarm = 80 mA Expansion Signal Module NAC Expander; NAC Expands module capacity to six, Class B NACs; 4100-1266 rating = 1.5 A, 50W, or 100 speakers maximum Supv. = 0.84 mA; Alarm 60 mA These modules mount on the Expansion Signal Module Class A Adapter; NAC Converts 3 Class B, NACs to Class A; Supv. = 1 mA; 4100-1267 rating = 1.5 A, SOW, or 100 speakers maximum Alarm = 30 mA select one max Expansion Signal Module Constant Supervision Converts 3 Class B NACs to Class B or Class A Constant per 4100-5116 4100-1268 Adapter for 25 VRMS or 70.7 VRMS; NAC rating Supervision NACs; Supv. = 38 mA on batteries (constant as required = 1.4 A, 50 W, or 100 speakers maximum supervision deactivated); Alarm = 70 mA 4081-9018 End-of-line resistor harness for 70.7 VRMS NACs; 10 kQ, 1 W 4100-2300 Expansion Bay Hardware; order one for each expansion bay 4100-2320 Audio Bay-to-Bay Interconnection Harness Kit; order one for each audio bay addition 4100-0637 Audio Box Interconnection Harness Kit; order one for each close-nippled audio cabinet Audio Input and Controller Options (see page 2 for custom message ordering) Model Description Details and Mounting Reference Auxiliary Audio Input Module; four additional Inputs for 10 VRMS, 25 VRMS, 70.7 VRMS, line level (0.707 VRMS), or 4100-1240 (unsupervised) inputs per module; 2 maximum microphone; 1 Block; current = 10 mA 4100-1241 8 Minute Message Expansion Module Provides 8 minutes at normal resolution 0r4 minutes at high Mounts to resolution, Supv. = 2 mA; Active = 17 mA audio 4100-1242 32 Minute Message Expansion Module Provides 32 minutes at normal resolution or 16 minutes at controller high resolution; Supv. = 2 mA; Active = 17 mA module Operator Interface and Related Options Model Description Details and Mounting Reference Microphone Module (mike); for One maximum per audio system; front panel module that requires 2 Slots (4"), Supervisory 4100-1243 Fire Alarm Control Panels locate on expansion bay only; space behind for 4100ES flat modules only current = Remote Microphone Module; Front panel module that requires 2 Slots (4"), locate on expansion bay only; 2.4 mA 4100-1244 for Remote Annunciator space behind for 4100ES flat modules only; distance limited to 4000 ft Active current Panels (1219m) =6mA 4003-9803 Remote Microphone Module Mounted on plate with controls, for 2-gang box mount, see data sheet S4100-0053 for details 4100-1252 1 Channel (audio or mike) Operator Interface LED/Switch Single Slot LED/switch modules; connects to a 4100-1288 or 4100-1289 LED/switch controller in the same bay; space behind controller accepts 4100ES flat modules only (see drawings on p.4); current = 24 mA; Additional adjacent LED/switch modules, as shown on p. 4, are used as 4100-1253 1.5 Channel (audio + mike) 4100-1254 2 Channel (full audio) 3-8 Channel (8 channel normal 4100-1255 res. messages, 4 channels of Modules required for specific speaker circuit selection (refer to data sheet high res. messages) S4100-0032 for LED/switch module availability) 4100-1288 64 LED/64 Switch Controller Refer to data Mounts behind the LED/switch modules; has I LED/switch controllers Module with mounting plate sheet S4100- 0032 for details provisions for one 4100-1289 Controller Module I and their connected I modules must be in 4100-1289 64 LED/64 Switch Controller Mounts on extra space of 4100-1288; controls Module without mounting plate additional 64 LEDs and 64 switches the same bay S Firefighter Telephone System Products Model Description Master Telephone with Control Module and 4100-1270 three Class B telephone NACs, one maximum per audio system; for use in Fire Alarm Control Panels only; includes one 4100-1272 Module 4100-1271 Remote Master Telephone 4100-1272 Expansion Telephone Control Module with three Class B telephone NACs 4100-1273 1 Telephone NAC Class A Adapter Module Details and Mounting Reference Front panel module; space behind for 4100ES flat modules only; phone control module included, mounted on bay module mounting plate; for individual telephone circuit control, use LED/switch modules; Supv. = 80 mA; in use = 140 mA + remote phones (see table on page 7 Mounts in Remote Annunciator Panel only (see S4100-0038) Expansion module for additional telephone circuits in main control or transponders; Supv. = 80 mA; in use = 140 mA + remote phones Mounts to 4100-1270 or -1272: no. additional current required Network and MINIPLEX Transponder Audio Connection Options 6 S4100-0034-14 6/2013 Expansion Bay Module Loading Reference Slot I Slot 2 Slot 3 Slot 4 slot Slot 6 Slot 7 Slot 8 Block A Block C Block E Block G Block B Block D Block F Block H Expansion Bay Chassis Size Definitions: Block = 4" Wx 5" F-I (102mm x 127 mm) card area Slot = 2" W x 8" H (51 mm x 203 mm) motherboard with daughter card 0 C ii7rn in ni Firefighter telephone systems provide two-way communications for facilities where radio communications may not be available or are unreliable. They are typically used during active firefighting conditions, during afire alarm investigation, or during fire alarm system inspection and test. System Operation. Connections are made using a common talk line (party line) that includes a Master Telephone and up to six remote telephones. Remote telephones call into the Master by either being taken off-hook or by being plugged into a telephone jack. The Master Telephone location receives a ring-in tone with a visible LED indicator for each telephone circuit. When the call is received, the operator selects the calling telephone circuit using the assigned switch control. The operator at the master location can place the original telephone circuit on hold and connect to additional telephone circuits or add them to the talk line. Master Telephone Operation. The Master Telephone connects directly into a telephone interface module. A Push-to-Talk (PTT) switch provides the operator with voice input control. Each master telephone uses local LED/switch modules to select telephone circuits and to silence any subsequent call-ins until selected. Telephone Circuit Control. A call request causes the local call-in tone sounder and assigned telephone circuit LED to pulse quickly. Pushing the calling circuit's switch silences the local sounder and connects that circuit to the talk line. Activating the switch again places that circuit on hold with a hold tone being heard at the remote telephones and causing that circuit's LED to pulse slowly. Subsequent pushes toggles from active to hold. Activating a telephone circuit switch when no call is incoming places a request to pick up on remote telephones equipped with local LEDs. Master telephones can be also be connected as an input to an audio controller module to allow audio system message broadcasting without using a microphone. Remote Master Telephones mount in Remote Annunciator Cabinets and are wired as the only connection to a telephone circuit. By adding local LED/switch modules, operation is that of the Master Telephone. Remote telephones are available cabinet mounted or for plugging into a dedicated telephone jack. Each hears a ring tone when a call-in is selected and a hold tone when placed on hold. When on hold, the remote telephones are each separated from the talk line. The Telephone Interface Module provides three Class B (Class A option is available) telephone circuits, connection for a master telephone, and a telephone riser input. One module is supplied when selecting a Master Telephone. Additional telephone interface modules can be added as required. Telephone circuit outputs can be programmed as remote telephones, as a Remote Master, or for telephone riser operation. Telephone circuits are supervised for opens, shorts, and overload conditions. The Master Telephone is supervised for broken cord or off-hook. Telephone riser operation can be programmed to provide a telephone riser output that is used to interconnect telephone interface modules in different locations. This output type has ring and hold tones disabled. Degraded Mode. If the telephone interface module loses communications with the host fire alarm control panel, telephone circuits off-hook are automatically connected to the talk line allowing any telephone to talk to another simply by being picked up (or plugged in). Master Telephone Control Current with Remote Telephones. The following table lists Master Telephone Control current with the addition of remote firefighter telephones. Remote 0 1 2 3 4 5 6 Phones Current(mA) 140 1 180 1 220 250 276 304 329 Description Mounting Audio Controller Modules Blocks A & B Network Riser Controller Module Block A Audio Riser Modules Block B EPS+, EPS, SPS, or RPS Blocks E, F, G & H ONLY XPS Blocks G & H ONLY" Flex-35 Amplifiers, 2 max /bay* E & F; C & D; Blocksor A & B Flex-50 Amplifiers, 2 max/bay" Blocks E & F or C & D 100 WAmplifiers, 1 max/bay Blocks E, F, G & I-I 100W Backup Amplifiers, 1 max. per bay with primary amplifier Blocks A, B, C & D Master or Remote Phone Module Blocks A & B Master or Remote Microphone Module Two vertical Blocks, any location (except next to telephone) Telephone Module 1 Block Expansion Signal Module 1 Block Operator LED/Switch Modules 1 Slot NPU to 4100ES Audio Interconnect Module 1 Block * NOTE: When mounting dual Flex amplifiers on an expansion bay, special mounting rules apply. S4100-0034-14 6/2013 (cI. Input Power Power Supplies; SF'S, xps, RPS, and 100 W Amplifiers 120 VAC Models 220-240 VAC Models 4 A maximum @ 102 to 132 VAC, 60 Hz 2 A maximum @ 204 to 264 VAC, 50/60 Hz; with taps for 220/230/240 VAC Enhanced Power Supplies EPS+ and EPS 120 VAC Models 220-240 VAC Models 4.6 A maximum @ 102 to 132 VAC, 60 Hz 2.3 A maximum @ 204 to 264 VAC, 50/60 Hz; with taps for 220/230/240 VAC AmDlifler Ratinas 500 Hz horn tone operated at temporal pattern, provided when amplifiers are separated from Built-in Tones audio controller Input Voltage 19 to 35 VDC from adjacent power supply Supervisory Current 425 mA with power stage supervised Flex-35 Amplifiers: 85 mA in low power mode 4100-1361 4100-1362 Use this value for power 4100-1363 Alarm Current 5.5 A with continuous horn tone supply loading 4100-1364 full output power 1.64 A average, with temporal pattern horn Use this value for battery backup reference Input Voltage 19 to 35 VDC from adjacent power supply Supervisory Current 425 mA with power stage supervised Flex-50 Amplifiers: 85 mA in low power mode 4100-1312 4100-1313 4100-1326 5.55 A with continuous horn tone Use this value for power 4100-1327 Alarm Current supply loading 2.27 A average, with temporal pattern horn Use this value for battery @ full output power backup reference 100 W Amplifiers and Backup Amplifiers: Supervisory Current 400 mA (analog); 220 mA (digital) with power stage supervised 4100-1314, 4100-1316, 4100-1318, 85 mA in low power mode 9.6 A with continuous horn tone 4100-1320, 4100-1322, 4100-1324; 4100-1328, 4100-1330, 4100-1332, 4100-1334, 4100-1336, 4100-1338 Alarm Current @ full output power 3.8 A average, with temporal pattern horn Use this value for battery backup reference Total Amplifier Power per Cabinet 300 W maximum Audio Controller Ratings I 4100-9620, 4100-1210 Analog = 225 mA supervisory Add for local speaker in alarm: 75 mA mm. volume; Current 1190 mA haff volume; 333 mA full volume; Requirements I Add microphone current separately; Supv.= 2.4 mA; 4100-9621, 4100-1311 Digital = 85 mA supervisory Active = 30 mA Analog Riser Distance Up to 10,000 ft (3048m) total with 18 AWG (0.82 mm2) shielded twisted pair (STP) Up to 2500 ft (762 m) from 4100-1311 Digital Controller to 4100-0622 Digital Audio Riser or Digital Riser Distance; 18 A\NG 4100-1341 MCC Digital Riser Interface; up to 2500 ft (762 m) between 4100-0622 Digital unshielded, twisted pair (UTP) required, Audio Riser Modules or 4100-1341 MCC Digital Riser Interfaces (signal is reformatted and except as noted (refer to Installation repeated); wire runs over 100 ft (30 m) require UTP wire Instructions 574-844)° * NOTE: Wire runs of 100 ft (30 m) or less require shielded twisted pair wire (STP) Firefighter Telephone Distance Ratings Distance 17500 ft (2286 m) distance to farthest phone, 18 AWG shielded twisted pair (STP) Battery Charger, System and Remote Power Supply (sealed lead-acid batteries) UL listed for battery charging of 6.2 Ah up to 110 Ah (batteries larger than 50 Ah require a Battery capacity range remote battery cabinet); ULC listed for charging up to 50 Ah batteries Charger characteristics and performance Temperature compensated, dual rate, recharges depleted batteries within 48 hours per UL Standard 864, to 70% capacity in 12 hours per ULC Standard S527 Environmental Operating Temperature Range 32° to 120°F (0° to 49° C) Operating Humidity Range Up to 930/c RH, non-condensing @ 90° F (32° C) maximum Additional 4I00ES Data Sheet Reference Subject Basic Panel with EPS/EPS+ Data Sheet S4100-0100 Subject Network Display Unit (NDU) Data Sheet S4100-0102 Subject Remote Firefighter Phones Data Sheet S2084-0001 Enclosures S4100-0037 LED/Switch Modules S4100-0032 Mic. Multiplex Module S4100-0053 MINIPLEX Transponders S4100-0103 SN, Addressable Strobe S4906-0006 Remote Battery Charger S4081-0002 Speakers S4902-0003 SN, SmartSync Strobe S4906-0003 Remote Annunciators S4100-0038 TYCO, SI]vIPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited f3,SiMpJIEX Tyco Fire Protection Products Westminster, MA 01441-0001 USA S4100-0034-14 6/2013 www.simplexgiinnell.com 02013 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. S S I I Node 5 (4100ES) 4100ES NDU with VCC, Node 1 and Node 2 Network One-Line Diagram Showing an NDU with VCC Listed to: UL Std. 864, Fire Detection and Control (IJOJZ), and Smoke Control Service (UTJKL) UL Std. 2017, Process Management Equipment (QVAX) UL Std. 1076, Proprietary Alarm Units-Burglar (APOU) UL Std. 1730, Smoke Detector Monitor (UTJLH) ULC Std. S527 Control Units for Fire Alarm Systems lntrndimtinn The 4100E5 NDU with VCC is a network level annunciator and manual system/point controller with Network voice control equipment. It provides alphanumeric annunciation for up to 12,000 Network points and/or point lists and can be programmed to function as the network master controller for Alarm Silence, Trouble Acknowledge, and System Reset. 55im pIEX S UL, ULC, CSFM Listed; FM Approved* 14I1Dk 4I00ES Network Annunciator Panels Network Display Units with Voice 10-ill".1clilve Command Center and EPS+ Power Supplies Node 4 (4100U) I 11!M_ Network Display Unit (NDU) provides annunciation for up to 12,000 network points: The basic NDU is a special purpose master controller that includes a network interface module An NDU with a Voice Command Center (VCC) mounted in the same cabinet provides an additional separate Network node within the same cabinet for control of Network level Emergency Voice/Alarm Communications Equipment NDU master controller equipment (top bay): Master controller assembly with operator interface 4100ES CPU with dual configuration programs, convenient service port access, and capacity for up to 12,000 points System power supply (SPS) and charger (9 A total) with on-board programmable auxiliary output Operator interface that is conveniently color coded with raised switches providing high confidence feedback . Available with InfoAlarm Command Center expanded content user interface (refer to data sheet S4 100-0101) Standard addressable interfaces include: Remote annunciator module support via RUT (remote unit interface) communications port NDU field installed option modules include: DACT and City Connection Service modems for remote panel status inquiry RS-232 ports for printers or maintenance terminals Alarm relays and expansion power supplies SafeLiNC Internet Interface VCC equipment (second expansion bay): VCC include Enhanced Power Supply (EPS+) and battery charger (9 A total) with on-board IDNA C SLCs (signaling line circuit) for addressable appliance control, IDNet 1+ isolated addressable device control channel, and programmable function auxiliary output For additional information concerning EPS+ power supplies and their enhanced features, refer to 4100ES data sheet S4100-0100 and refer to additional related product data sheet list on page 9 Voice control options are similar to a networked fire alarm control panel with an extensive list of modules available for initiating, notification, and user interface * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:0251 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4100-0102-1 5/2013 NDU Master Slot 4 Master Controller Board: Slot 3 is Network tnterface Slot 4 is Master Controller Expansion Bay 1 Master Controller Board: Slot 3 is Network Interface Expansion bay with Slot 4 is Master Controller mixed module sizes NDU with VCC xpansion Bay 2 E:J POt board with two connectors available - - EPS+ Power Supply hlDNet1+Module 0 9 NDU with VCC Internal Module Bay Reference (exact layout is determined by specific system requirements) Packaging Availability Modules are power-limited (unless specifically noted otherwise) Enclosure are available for one, two, or three bay sizes or for cabinet rack mounting Additional cabinets can be mounted close-nippled for module expansion Boxes, doors with tempered glass inserts, and dress panels are available in beige or red (ordered separately) Refer to data sheet S4100-0037 for enclosure details &Tel U1i7 1! liii Ii1i"j Selectable service override allows authorized operators to clear alarm conditions during System Reset even if status has gone to trouble before reset occurred Duplicate address error detection Convenient PC programming using a Microsoft Windows user interface based program Ir T(.fThYIIi1iT7k1 Network Overview. When connected to other Network nodes, individual fire alarm control panels become components of a distributed intelligence system. Each panel that directly connects to the network is called a network "node" and is capable of performing individual supervision and control on its locally connected devices but has the ability to inform the 4100ES NDU (as well as other network control panels) of point status and panel condition. This allows system information to reach the proper location for appropriate system response. Multiple 4100ES NDUs (separately packaged) can be connected to a Network to duplicate common information at separate locations, or direct selected information by type such as troubles, alarms, control, etc. II'1uI'ir iii F1t1 The NDU Master Controller Bay (top) includes, a special purpose system power supply with battery charger (SPS), the master controller board, a Network Interface Module, and operator interface equipment similar to that used on the standard fire alarm control modules. Slots 1 and 2 are available for single slot panel mounted modules. The VCC includes an expansion bay with separate: master controller board, Network Interface Module, and an EPS+ power supply. This results in two separate Network nodes residing within the same cabinet. In the VCC bay, a dual PDI connection is available for either a dual slot module, or one or two block modules. Optional LED/switch modules can also be mounted. For 2-bay cabinets, the VCC mounts in bay 2. For 3-bay cabinets as shown to the right, the VCC mounts in the second expansion bay, bay 3. The Battery Compartment (bottom) accepts two batteries, up to 50 Ali, to be mounted within the cabinet without interfering with module space. Refer to the NDU with VCC internal module bay reference illustration for typical three bay cabinet module location. I..] tl 1i1 Ffl(1i The following illustration identifies the primary functions of the operator interface. Operator interface panel is directly Ethernet port access are printed on the interface (under sliding cover) mounting plate S4100-0102-1 5/2013 5 Convenient Status Information. With the locking door closed, the glass window allows viewing of the display, status LEDs, and available operator switches. Features include a two-line by 40-character, wide viewing angle (super-twist) LCD with status LEDs and switches as shown in the illustration below. LED indicators describe the general category of activity being displayed with the LCD providing more detail. For the authorized user, unlocking the door provides access to the control switches and allows further inquiry by scrolling the display for additional detail. 11ti 'N t1MOMF 31I i* Convenient and extensive operator information is provided using a logical, menu-driven display Multiple automatic and manual diagnostics for maintenance reduction Alarm and Trouble History Logs (up to 1250 entries for each, 2500 total events) are available for viewing from the LCD, or capable of being printed to a connected printer, or downloaded to a service computer Convenient PC programmer label editing Password access control FIRE ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts SIX SYSTEM STATUS INDICATOR LEDs PRIORITY 2 ACK acknowledges a PriorIty 2 Alarm provide system status indications in addition condition, logs the acknowledge, and silences the to LCD information, LEDs flash to indicate the operator panel and all annunciator tone-alerts ULC SYSTEMS condition and then when acknowledged, SUPV ACK acknowledges system supervisory require designating remain on until reset: ] conditions, logs the acknowledge, and silences the a Ground Fault Fire Alarm & Priority 2 Alarm, red LED operator panel and all annunciator tone-alerts indicator Supervisory & Trouble, yellow LED Alarm Silenced, yellow LED TROUBLE ACK acknowledges system troubles, logs AC Power, green LED (on for normal) the acknowledge, and silences the operator panel and all annunciator tone-alerts 1THREE PROGRAMMABLE LEDs ______________________________ ALARM SILENCE causes audible notification provide custom labeling, the top 112 X 40 LCD READOUT, LED backlighted appliances to be silenced (depending on panel S I during normal conditions and abnormal I two LEDs are selectable as red or I programming) typically after evacuation is complete and I yellow, the bottom LED is / operating conditions, provides up to 40 while alarm source is being investigated; may allow selectable as green or yellow characters for custom label information L visible notification to continue (strobes still flashing) I FIRST ALARM DISPLAY: Operation can [Custom label insert) / be selected for maintained display of first SYSTEM RESET restores control panel to normal when all alarmed inputs are returned to normal alarm until acknowledged Watertlow-East SYSTEM IS NORMAL 12:25: 15 am MON 20-MAY-13 l #'° 4/frt•5. '-. essestt. .pe-sv ,) (GrondFh) (ID Eeoc Ll 01 f City Disconnect OQtorRecaD) 0OsIii Q GroundFautl Latch I FIVE PROGRAMMABLE I POINT STATUS I ADDITIONAL FUNCTION I I LCD NAVIGATION I I Menu selection each with a yellow LED I FUNCTION SWITCHES, I CONTROL KEYS: I KEYS: I CONTROL: L I Disable I More Information Request Vertical and indicator j Point Enable and I Event Time Request Force On or Arm ULamp Test I Horizontal position Force Off or Disarm selection buttons Return On/Off or Arm/Disarm to Auto Mode NUMERIC KEYPAD for point category and point selection (alphabet characters are not used at this time) 3 S4100-0102-1 5/2013 FIRTWIMMI.T.MrIon- R3 NDU (top bay) Master Controller & Motherboard: Mounts in Slot 4 of a two slot motherboard (Slots 3 and 4 of the Master Controller Bay) and provides one Style 4 or Style 7, RUT communications channel, available at Slot 4 RUT communications controls up to 31 devices per master controller at up to 2500 ft (762 m) for single run, or 10,000 ft (3048 m) total if wiring is Class B and T-tapped; if more distance is required, up to four total REJI channels are supported; add up to three 4100-1291 RUII expansion modules (the VCC with EPS+ Power Supply provides an RUI+, isolated output for improved noise rejection) RUT remote equipment includes: MIITPLEX transponders, 4603-9101 LCD Annunciators, 4602-9101 Status Command Units (SCU), 4602-9102 Remote Command Units (RCU), 4602 Series LED Annunciator Panels, 4100 Series 24 110 and LED/Switch modules A Network Interface Module is mounted in Slot 3 Optional Service Modem 4100-6030 mounts onto the master controller board with its own on-board connections System Power Supply (SPS) is rated for 9 A total, including module currents; NACs and IDNet SLCs are disabled for NDU VCC (second expansion bay) includes an EPS+ Power Supply: Rating is 9 A total with "Special Application" appliances Outputs are power-limited, except for the battery charger VCC CPU provides RUI+ communications with isolated output Provides system power, battery charging, auxiliary power, earth detection, on-board IDNet 1+ communications channel for 250 points, three on-board IDNACs, and allows either an optional City Connect Module or an optional Alarm Relay Module EPS+ Power Supply (Continued): IDNet 1+ SLC Output provides Class B or Class A communications for up to 250 addressable devices Battery Charger is dual rate, temperature compensated, and charges up to 50 Ah sealed lead-acid batteries mounted in the battery compartment (33 Ah for single bay cabinets); also is UL listed for charging up to 115 Ah batteries mounted in an external cabinet (see data sheet S2081-0012 for details) Battery and Charger Monitoring includes battery charger status and low or depleted battery conditions; status information provided to the master controller includes analog values for: battery voltage, charger voltage and current, actual system voltage and current, and individual IDNAC SLC currents Low Battery Cutout is selectable for each EPS+ (and EPS) power supply, Canadian models are shipped selected, other models are shipped unselected 2 A Programmable Output: Select for conventional NAC operation to provide supervised reverse polarity for sounder base power, Suppression Release Peripheral (SRP) power, and other coded NAC operation requirements Select for Auxiliary (AUX) operation for sounder base power, 4-wire detector power, or door holder; supervised AUX operation does not require an end-of- line relay to provide Power-Limited operation EPS+ Power Supply Mounted Optional Modules (select one): City Connect Module (4100-6031, with disconnect switches, or 4100-6032, without disconnect switches) can be selected for conventional dual circuit city connections Alarm Relay Module (4100-6033) provides three Form C relays that are used for Alarm, Trouble, and Supervisory, rated 2 A resistive @ 32 VDC S S \iVWMI mm M. \ Model Voltage Description Supv Alarm \ Top Bay Equipment: LCD and operator interface, 9 A System Power 417 mA 770 mA - 120 VAC, Supply (SPS) with RUI, Standard CPU module, and Network Interlace 41 00-9342 50/60 Hz Module (select media cards separately) (NOTE: SPS IDNet channel With 200 IDNet devices and and NACs are disabled) 20 device LEDs in alarm Second Bay Equipment: Voice Command Center (VCC) Bay with 220-240 VA Standard CPU Module, Network Interface Module (select media cards 4100-9542 50/60 HzC, separately), 9 A EPS+ with 250 Point IDNet 1+ Interface, (3) 3 A IDNACs, and RUI+ output * For InfoAlarm Command Center expanded content display products, refer to data sheet S4100-0101. See next page for selected Network Media Card current S4100-0102-1 5/2013 Communication Modules Model 4100-6056 Description Wired Network Media Card Select per Network connection requirements, two media cards are required per network interface mounts on the Fiber Optic Media Card supplied Network Interface Module(s) Size N.A. Supv. 55 mA Alarm 55 mA 4100-6057 N.A. 25 mA 25 mA 4100-6055 Network Access Dial-in Service Modem, mounts to supplied Network Interface Module, requires telephone line connection N.A. 60 mA 60 mA 4100-1291 Remote Unit Interface Module (RUl); up to three maximum per control panel 1 Slot 85 mA 85 mA 4100-6030 Service Port Modem for local panel access only, mounts to Master Controller Module requires telephone line connection, accesses same information as front panel port N.A. 70 mA 70 mA 4100-6031 Select one per SPS, EPSI-, or EPS City Circuit, with disconnect switches N.A. 20 mA 36 mA 4100-6032 City Circuit, without disconnect switches N.A. 20 mA 36 mA 4100-6033 Alarm Relay, 3 Form C relays, 2 A @ 32 VDC N.A. 15 mA 37 mA 4100-6046 Dual Port RS-232 standard interface (single block) 13 maximum RS-232 I modules per panel 1 Block 60 mA 60 mA 4100-6038 Dual RS-232 with 2120 Interface (slot module) i Slot 132 mA 132 mA 4100-6080 DACT, Point or Event Reporting; 1 shipped unless 4100-7908 is selected; 2 max. per system; includes 2, 2080-9047 cables, 14 ft (4.3 m) long, RJ45 plug and spade lugs Side Mt 30 mA 40 mA 4100-6101 Physical Bridge, Class B, includes 1 modem module and 2 wired modules 1 Slot 210 mA 210 mA 4100-6102 Physical Bridge, Class A, includes 2 modem and 2 wired modules 2 Slots 300 mA 300 mA 4100-0156 8 VDC Converter, required for multiple Physical Bridge Modules; 3 A @ 8 VDC maximum 1 Block included with loads 4100-9816 Master Clock Interface Module with one standard RS-232 port (see S4100-0033) 1 Slot 132 mA 132 mA 4190-6104 Truelnsight Remote Monitoring Module (refer to data sheet S4100-0063 for details) Side Mt. 62 mA 73 mA 4100-6079 SafeLlNC Internet Interface module 1 2 Blocks 145 mA 145 mA 00\ NDU with VCC, LED/Switch Modules (refer to S4100-0032 for additional detail) S N S LED/Switch Modules, General Purpose (LED/switch controller and label kit is ordered separately) Model 4100-1276 LEDs per Switch LEDs only LED Color(s) Red; pluggable LED Quantity 8 Switch Quantity LEDs only 4100-1277 Red on top, Yellow on bottom, pluggable 16 4100-1280 One Red 8 8 4100-1281 One Yellow 4100-1282 Two Red on top, Yellow on bottom 16 4100-1283 Two Yellow, top and bottom 4100-1284 Two Red on top, Green on bottom 4100-1296 Two Green on top, Yellow on bottom 4100-1285 One Red 16 8 Red on left, 8 Yellow on right 16 4100-1278 One 4100-1287 One Red 24 24 LED/Switch Model 4100-1286 Modules, SpecialPurpose (LED/switch controller and label kit is ordered separately) Operation Eight function HOA (On, Off, Auto) Control Module with labeled switches; ON/OFF/Auto; Green/Red/Green LEDs 4100-1295 Eight function HOA (On, Off, Auto) Control Module, same as 4100-1286 except switches are unlabeled LED/Switch Controller Modules and Accessories Model Description 64 LED/64 Switch Controller Module with mounting plate; controls up to 64 4100-1288 LEDs and interlaces to up to 64 switches; mounts behind the LED/switch modules and has provisions for one 4100-1289 Controller Module 4100-1 289 64 LED/64 Switch Controller Module without mounting plate; mounts on extra space of 4100-1288; controls an additional 64 LEDs and 64 switches 4100-1294 LED/Switch Module Slide-in Labels, required when LED/switch modules are Model Color I Model I Color I Model I Color I Description 4100-9843 Yellow 1 4100-9844 1 Green 1 4100-9845 1 Red I Kits of 8 LEDs; order as required for 4100-1276/1277 modules NOTE: LED/switch controllers and their connected LED/switch modules must be in the same bay; refer to data sheet S4100-0032 for additional LED/Switch module details when Flex-35/50 amplifiers are in the same bay order one per cabinet 5 S4100-0102-1 5/2013 VCC, Emergency Voice/Alarm Communications Selection* Model Description 4100-1243 Master Microphone Module; one maximum per audio system; mounts on front panel 4100-1252 1 Channel (audio or mike) I \ 4100-1253 1.5 Channel (audio + mike) Operator I Interlace 4100-1254 2 Channel (full audio) I Modules 4100-1255 3-8 Channel I Details and Mounting Reference Requires 2 Slots (4" [102 mm]), locate on expansion bay only; space behind for 4100ES flat modules only Supv. current = 2.4 mA; Active current = 6 mA Single slot modules requiring connection to an LED/switch controller (see data sheet S4100-0032 for LED/Switch Module details); space behind controller accepts 4100ES flat modules only Additional adjacent LED/switch module(s) are required for specific speaker circuit selection C S Firefighter Telephone System Products (refer to S4100-0034 for additional detail) Model Description Details and Mounting Reference Master Telephone with Telephone Control One max. per audio system; front panel module; space behind for 4100E5 flat 4100-1270 Module and 3 Class B telephone NACs; for modules only; telephone control module mounts on bay module mounting Fire Alarm Control Panels plate; use LED/switch modules for circuit control 4100-1272 Telephone Module with 3 phone NACs Class B NACs, single Block module, mounts to bay mounting plate 4100-1273 1 Telephone Class A Adapter Module Mounts to 4100-1272, no additional space required Analog Emergency Voice/Alarm Communications Equipment Constant Supervision Compatible* Model Description Details 4100-9620 Basic Analog Audio Operation with microphone, requires Includes: Expansion Bay, 4100-1210 Analog Controller Board, dedicated expansion bay Microphone Module, and Audio Expansion Bay Kit 4100-1210 Analog Controller Board only; order expansion bay and Controller board mounts in Blocks A and B audio expansion bay kit separately 4100-1361 125 VRMS output Flex-35, 35W Amplifier, Includes three on-board I NAC rating = 1.4 A I 35W, or 100 4100-1362 70.07 VRMS output constant supervision compatible Class B audio NACs; I NAC rating = 0.5 A I speakers 4100-1312 25 VRMS output I Flex-50, 50W Amplifier, power is supplied from an NAC rating 2 A I 50W, or 100 XPS, SPS, EPS+, or EPS I I 4100-1313 70.7 VRMS output constant supervision compatible NAC rating = 0.707 A speakers 100W Analog Amplifiers with Power Supply, Constant Supervision Compatible* Model/Output Voltage 25 VRMS 70.7 VRMS Power Supply Input/Listing Description Details 4100-1314 4100-1315 120 VAC, 60 Hz UL Prim Includes six, Class B audio NACs; 4100-1316 4100-1317 12O VAC, 60Hz ULC inn2' NAC rating=50Wor 100 speakers ULC Amplifier maximum; 2 A @ 25 VRMS; models 1.4 4100-1318 4100-1319 220/230/240 VAC, 50/60 Hz UL A @ 70.7 VRMS have low 4100-1320 4100-1321 120 VAC, 60Hz UL Backup 100W Amplifier Uses the six Class B NACs of primary amplifier circuit battery dropout 4100-1322 4100-1323 12O VAC, 60Hz ULC 4100-1324 4100-1325 220/230/240 VAC, 50/60 Hz UL Digital Emergency Voice/Alarm Communications Equipment* Model Description Details 41009621 Basic Digital Audio Operation with microphone, requires Includes: Expansion Bay, 4100-1311 Digital Controller Board, dedicated expansion bay Microphone Module, and Audio Expansion Bay Kit 4100-1311 Eight Channel Digital Controller Board only; order Controller board mounts in Blocks A and B expansion bay and audio expansion bay kit separately 4100-1363 25 VRMS output I Flex-35, 35 WAmplifier, constant supervision compatible Includes three on-board Class B audio NACs; power is supplied from an xpS, SPS, EPS+, or EPS NAC rating = 1.4 A 35W, or 100 I speakers 4100-1364 70.07 VRMS output I NAC rating = 0.5 A 4100-1326 25 VRMS Output I Flex-50, 50 WAmplifier, constant supervision compatible I NAC rating = 2 A I 50W, or 100 speakers 4100-1327 70.7 VRMS output 1 NAC rating = 0.707 A 100 W Digital Amplifiers with Power Supply, Constant Supervision Compatible* Model/Output Voltage Power Supply Input/Listing Description Details 25 VRMS 70.7 VRMS 4100-1328 4100-1329 120 VAC, 60 Hz UL Prima Includes six, Class B audio NACs; ry ULC 4100-1330 4100-1331 120 VAC, 60 Hz ULC 100W NAC rating = 50 Wor 100 speakers models maximum; 2 A @ 25 VRMS; 4100-1332 4100-1333 220/230/240 VAC, 50/60 Hz UL Amplifier 1.4 A @ 70.7 VRMS have low 4100-1334 4100-1335 1 12O VAC, 60Hz UL Backup Uses the six Class B NACs of primary battery dropout 4100-1336 4100-1337 120VAC,60Hz ULC 100W Amplifier amplifier circuit 4100-1338 4100-1339 220/230/240 VAC. 50/60 Hz UL Options for use with either Analog or Digital Amplifiers* Model Description Model Description 5 4100-1245 Flex-35/50 NAC Expansion Module; (Adds 3 4100-1248 100 WAmplifler NAC Expansion Module; (Adds six Class B, 1.5 A NACs) Class B, 2 A NACs) 4100-1246 Flex-35/50 Class A Adapter for 3 NACs 4100-1249 100 W Amplifier Class A Adapter Module for 6 NACs * Refer to document S4100-0034 for additional audio module information. Continued on next page 6 S4100-0102-1 5/2013 S VCC, Emergency Voice/Alarm Communications Selection (Continued) Options for either Analog or Digital Systems (refer to data sheet S4100-0034 for additional module details) Model 4100-1259 Description Constant Supervision Adapter for 25 VRMS Amplifiers Model 4100-5116 Description Expansion Signal Module; three, 1.5 A NACs 4100-1260 Constant Supervision Adapter for 70.7 VRMS Amplifiers 4100-1266 NAC Extender Options for use with 4100-1240 Auxiliary Audio Input Module; four additional inputs 4100-1267 Class A Adapter Expansion Signal 4100-1241 8 Minute Message Expansion Module 4100-1268 Constant Supervision Adapter Module 4100-1242 132 Minute Message Expansion Module 4081-9018 End-of-line resistor for 70.7 VRMS NACs; 10 kn, 1 W 4100-0623 1 Network Audio Riser Controller Module for control of analog (-0621) or digital (-0622) riser module, see 54100-0034 for details VCC, Additional Options Model Description 4100-5152 12 VDC Power Ootion. 2 A maximum: 1 Block. 1.5 A maximum Suoervisory or Alarm 4100-0156 8 VDC Converter, required for multiple Physical Bridge Modules, 3 A maximum, 1 Block, current included with loads 4100-0634 120 VAC Power Distribution Module (PDM); select per system voltage; one required per box or cabinet rack 4100-0635 220/230/240 VAC 4100-6034 Door Tamper Switch with built-in addressable IDNet lAM, one per cabinet assembly if required 4100-2320 Audio Bay-to-Bay Interconnection Harness Kit; order one for each audio bay addition 4100-0637 Audio Box Interconnection Harness Kit; order one for each close-nippled audio cabinet 4100-9835 Termination and Address Label Kit (for module marking); provides additional labels for field installed modules 4100-1290 24 Point I/O Module; I Slot (see data sheet S4100-0032 for details) 4100-1293 Panel Mount Thermal Printhead Printer, supplied with one roll of paper; requires 3 Slots; see S4100-0032 for details 4190-9803 Replacement Paper for 4100-1293 Printer, one roll 4100-6045 Coded Manual Station Decoder Module; 3 Slot module; 85 mA supervisory, 163 mA alarm; see S4100-0018 for details 4100-6048 VESDA Air Aspiration Interface; 1 Slot module; 132 mA supervisory or alarm, see S4100-0026 for details 4100-1279 Single blank 2" display cover; order as required (8 fill a bay front); two max. in a row between LED/switch modules 4100-2210 Appliqué, Canadian French, 4100ES Fire Control 4100-2300 Expansion Bay Hardware, order for each expansion bay (unless included with selected option) 4100-0636 Box Interconnection Harness Kit; order one for each close-nippled cabinet 4100-0632 Terminal Block Module; 2, 16 position terminal blocks mounted on 4" x 5" single block size, for up to 12 AWG wire (3.31 mm 2) 4100-5128 Battery Distribution Terminal Block; mounts to side of box; required for close-nippled cabinets that interconnect battery wiring Model 4100-3202 Description 4 DPDT Relay w/feedback Resistive Ratings 10 A@ 250 VAC Inductive Ratings 10 A @ 250 VAC Size 2 Slots Supv. 15 mA Alarm 175 mA 4100-3204 4 DPDT Relay w/feedback 2 A © 30 VDCNAC 1/2 A @ 30 VDC/120 VAC 1 Block 15 mA 60 mA 4100-3206 18SPDTRelay 3A@3OVDC/12OVAC 1-1/2A@3OVDC/12OVAC 1 Block 15 mA 190 mA Additional Enhanced, Expansion, and Remote Power Supplies, and Accessories Model Voltage/Listing Description . Size Supv. I Alarm 4100-5311 120 VAC UL & ULC Additional Enhanced Power Supply (EPS+); 9 A Enhanced 217 mA I 480 mA Power Supply/battery charger with 250 point IDNet 1+ interface, 3 Class B IDNAC SLCs, and RUI+ isolated output 4 Blocks Right I with 200 IDNet 4100-5313 220-240 VAC UL communications interface; 120 VAC model has selectable low Side devices and 20 battery cutout device LEDs in alarm 4100-5325 120 VAC UL&ULC Enhanced Power Supply (EPS) 9 A Enhanced Power 4 Blocks Supply/battery charger with 3 Class B IDNAC SLCs, and RUI+ Right 125 mA 220 mA 4100-5327 220-240 VAC UL isolated interface; 120 VAC has output communications model Side selectable low battery cutout Dual Class A IDNAC Isolator (DCAI), converts a single Class B IDNAC SLC input to two Class A or two Class B SLC outputs; provides short circuit isolation between each Class A 4100-6103 or B output circuit; connect up to two DCAI modules per IDNAC SLC input up to a 1 Block 6.5 mA 6.5 mA maximum of 6 DCAI modules per EPS; each isolated output SLC used requires one IDNAC address; the total current remains controlled by the Class B input source SLC at 3 A maximum 4100-5101 120 VAC UL Expansion Power Supply (XPS); 9 A output, 3 built-in Class A/B NACs, rated 3 A for Special Application appliances 120 VAC, 4100-5103 Canadian ULC (2 A for Regulated DC); NACs can be selected as auxiliary power outputs, derated to 2 A for continuous duty, total per XPS 2 Blocks 50 mA 50 mA 4100-5102 220-240 VAC UL is 5 A; 4100-5103 has low battery cutout 4100-5115 1 NAC Expansion Module, 3 NACs, Class NB, mounts on XPS only N.A. 25 mA 1 25 mA 7 S4100-0102-1 5/2013 Enhanced Power Supplies, 120 VAC Models 4.6 A maximum @ 102 to 132 VAC, 50/60 Hz 220-240 VAC Models 2.3 A maximum @ 204 to 264 VAC, 50/60 Hz; EPS/EPS+ Input separate taps for 220/230/240 VAC Power System Power Supply (SPS) 120 VAC Models 4 A maximum @ 102 to 132 VAC, 50/60 Hz 220-240 VAC Models 2 A maximum @ 204 to 264 VAC, 50/60 Hz; Expansion Power Supply (XPS) 100 W Amplifiers separate taps for 220/230/240 VAC Total Power Supply Including module currents and auxiliary power outputs; Power Supply Output Rating 9 A total for "Special Application" appliances Output Ratings for IDNAC Output Voltage EPS/EPS+ Output switches to Regulated 29 VRMS 2 A maximum Auxiliary Power Tap battery backup during mains AC Power Supply Output Total Power Supply 9 A total including module currents and auxiliary power Ratings for SPS and Output Rating outputs failure or brownout XPS Auxiliary Power Tap conditions 2 A maximum . I (nominal 28 VDC on I 2 A maximum per NAC; AC; 24 VDC on battery NACs Programmed Rated 19.1 to 31.1 VDC backup) for Auxiliary Power 5 A maximum total Compatible Special Application Appliances Simplex TrueAlert ES and TrueAlert addressable notification appliances; contact your Simplex product representative for compatible appliances IDNet 1+ Wiring Specifications (refer to installation instructions for more information) Maximum Distance from Control Panel 0 to 125 4000 ft (1219 m); 50 ohms 2500 feet (762 m); 35 ohms per Device Load 126-250 Total Wire Length Allowed With "T" Taps for Up to 12,500 ft (3.8 km); 0.60 pF Class B Wiring Maximum Capacitance Between lDNet+ Channels 1 pF Shielded or unshielded, twisted or I Some applications may require shielded wiring. Wire Type and Connections untwisted wire I Review your system with your local Simplex product supplier. Connections Terminal blocks for 18 to 12 AWG IDNAC SLC Wiring Specifications (refer to installation instructions for more information) Recommended wire type UTP, unshielded twisted pair Up to 63 addresses and I I Appliances are typically one unit load, devices such as IDNAC SLC Capacity up to 75 unit loads I Isolators may require more than one load, refer to individual device data sheet for specific information. Maximum wire length allowed with "T-Taps" for 10,000 ft (3048 m) Class B wiring, per SLC Maximum wire length per SLC to any appliance 4000 ft (1219 m) Maximum wiring resistance between appliances 260. Wiring connections Terminal blocks for 18 to 12 AWG Battery Charger Battery capacity range UL listed for battery charging of 6.2 Ah up to 115 Ah (batteries larger than 50 Ah Ratings for require a remote battery cabinet); ULC listed for charging up to 50 Ah batteries EPS/EPS+ and SPS (sealed lead-acid Charger characteristics Temperature compensated, dual rate, recharges depleted batteries within 48 batteries) and performance hours per UL Standard 864; to 70% capacity in 12 hours per ULC Standard S527 Environmental Operating Temperature 32° to 120°F (0° to 49° C) Operating Humidity Up to 93% RH, non-condensing @ 90° F (32° C) maximum Additional Technical Reference Description Document Network Display Unit Installation Instructions 579-269 ES Installation Instructions 574-848 ES Operating Instructions 579-197 IDNet 1+ Module Installation Instructions . 579-1014 EPS/EPS+ Installation Instructions 579-1015 DCAI Module Installation Instructions 579-1029 S S 8 S4100-0102-1 5/2013 Expansion Bay Module Loading Reference (exact locations are provided with shipped product) S 91 Fri Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Block A Block C Block E Block G Block B Block 0 Block F Block H Expansion Bay Chassis Size Definitions: 1 Block = 4W x 5.65" H (102 mm x 144 mm); (often called 4 x 5 modules) Slot = 2" W x 8" H (51 mm x 203 mm) motherboard with daughter card Description Mounting Terminal Block Module 1 block Class B Physical Bridge 2", 1 slot Class X Physical Bridge 4", 2 slots System, Remote, or EPS Power Supply Blocks E, F, G & H ONLY Expansion Power Supply Blocks G & H ONLY Audio Controller Modules Blocks A & B Flex-35 Amplifiers, 2 max/bay* Blocks E&F;C & D; or Flex-50 Amplifiers, 2 max/bay* Blocks E & F or C & D 100 WAmplifiers, 1 max/bay Blocks E, F, G & F-I 100W Backup Amplifiers, 1 max. per bay with primary amplifier Blocks A B C & D Master Telephone Module Blocks A& B Master Microphone Module (do not mount next to telephone) Two vertical Blocks, any location Telephone Module 1 Block Operator LED/Switch Modules 1 Slot * NOTE: When mounting dual Flex amplifiers on an expansion bay, special mounting rules apply. Additional 4100ES Data Sheet Reference Subject 4100ES NDU for conventional (non-addressable) notification applications) Data Sheet S41000036 Subject 4100ES Audio/Phone Modules Data Sheet S4100-0034 SafeLINC Fire Panel Internet Interface S4100-0062 4100ES with EPS Power Supplies, Basic Panel Modules and Accessories S4100- 0100 Remote Annunciators S4100-0038 Remote Battery Charger S4081-0002 InfoAlarm Command Center for 4100ES Panels with EPS Power Supplies S4100-0101 Fiber Optic Modems S4100-0043 Truelnsight Remote Service S4100-0063 MINIPLEX Transponders with EPS Power Supplies S4100-0103 TrueSite Workstation S4190-0016 4100ES Enclosures S4100-0037 Master Clock Interface Module S4100-0033 LED/Switch Modules S4100-0032 S S4100-0102-1 5/2013 Wall Mounted Enclosure Installation Reference Front view, box outline without door Side view with door attached Door thickness I 4-3/4 3 Bay height = 56(1422mm) (121 mm) Knockout screw/nail holes (for semi-flush mounting) Exposed cabinet for 2 Bay height = semi-flush mounting 40" (1016 mm) 1-3/6' (35 mm) minimum Wall board reference for semi-flush I mounting, 6" stud 1 Bay height = 22" (559 mm) JJJ_, Exposed door and cabinet for semi-flush mounting 1 Doors _can be hinged left or_rigJ—' 6-1/8" (156 mm) minimum Stud alignme nt mark ers, each side j I [6" stuIJ I Optional semi-flush trim kit reference /4__stud k629/32" 4 24" (610 mm) (175 mm) (296 mm) NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. Microsoft and Windows are registered trademarks ofMicrosoft Corporation. VESDA is a trademark of Vision Products Pty Ltd. 0 ®S mi p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4100-0102-1 5/2013 02013 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision dale and are subject to change without notice. 4100ES Two Bay Cabinets ------------------- 4100ES Three Bay Cabinets 49 TPS 4009 TPS Cabinet Assembly (not to scale) LiSim pIEX S UL, ULC, CSFM Listed, FM MEA (NYC) Acceptance* I14!I(4.1 4I00ES Box and door options: Boxes are available sized for one, two, or three equipment bays, each with a battery bay located at the bottom Colors include platinum or red Doors are glass front with modular dress panels, or solid Models are available with box and door combined for single package shipping, or packaged separately Enclosures are NEMA 1 rated Refer to individual 4100ES data sheets for product application listings (see list on page 2) Door and dress panel selection is coordinated with cabinet function: Glass doors with modular dress panels provide visibility of annunciation and interface modules for Control Panels, Network Display Units (NDU), and Remote Annunciators • Solid doors are for Iv1IITPLEX Transponders and utility function cabinets where module visibility is not required 4I00ES Enclosure details: Latching dress panels easily lift off for internal access Smooth box surfaces are provided for locally cutting conduit entrance holes exactly where required Alignment markers are provided at the top and bottom of each box side for 6" (152 mm) or 4" (102 mm) wall studs Knockout screw/nail holes are supplied for semi-flush mounting Upright cabinet rack packaging reference: For use with Bud Industries Inc. special cabinet rack model number 45964 Refer to page 2 for cabinet rack listing 4009 TPS (TrueAlert Addressable Power Supply) cabinet assemblies: Cabinet assemblies are available for remote mounting of the TrueAlert addressable power supply (TPS) Refer to page 2 for listings information * For 4100ES one, two, and three bay cabinets with associated equipment: Products are listed by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:251 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact your local Simplexu product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4I00 Fire Control Panels Cabinet Reference; Boxes, Doors, Dress Panels, Rack Mounting, and Accessories S4100-0037-10 10/2011 Combined Box and Door Selection (select if box and door are to be shipped together) Description Platinum I Bay Platinum 2 Bay Platinum 3 Bay 1I/fed I Bay Red 2 Bay ed 3 Bay Box with Glass Door and Dress Panel 2975-9444 2975-9445 2975-9446 12975-9441 2975-9442 2975-9443 Box with Solid Door 2975-9450 2975-9451 2975-9452 I 2975-9447 2975-9448 2975-9449 Model Color Description Details 4009 TPS Includes box with door and mounting plate, input terminal block, and wiring harnesses; 2975-9230 Beige Cabinet Separately Order. 4100 Series TPS (4100-5120 for US, 4100-5121 for Canada, 4100-5122, Assembly for remote TrueAlert 240 VAC for international use), 4009-9813 Interface Card, and batteries (12.7 Ah maximum for cabinet mounting); refer to page 3, to data sheets S4100-0031 and S4009-0003, and 2975-9229 Red Power Supply instructions 579-875 for additional details [ Listings: ETL Listed to UL864 & ULCS527; (TPS) mounting CSFM listed under 7300-0026:0368; FM Approved; NYC Fire Dept. acceptance] Separate Box and Door Selection (select if boxes and doors are required to be shipped separately) Description Platinum I Bay Platinum 2 Bay Platinum 3 Bay Red I Bay Red 2 Bay Led 3 Bay Box 2975-9438 2975-9439 2975-9440 2975-9407 2975-9408 2975-9409 Glass Door and Dress Panel 4100-2104 4100-2105 4100-2106 4100-2124 4100-2125 4100-2126 Solid Door 4100-2114 4100-2115 4100-2116 4100-2134 4100-2135 4100-2136 Cabinet Rack Mounting (refer to page 4 for additional details) Model Description #45964 Listings #45964, Special upright cabinet rack for 41•OOES; 19" (483 mm) E.I.A.; UL and ULC listed only as of document revision from Bud gray texture; includes front polycarbonate door and rear date; cabinets are listed with the Simplex Industries Inc. louvered door, both keyed with Simplex "B" keys 4100ES product line 4100-2140 Master Controller Rack Mount Kit, one required per master controller Master Controller and Option Bays each require 9 Rack Units; 15.75" 4100-2145 Option Bay Rack Mounting Kit, one required per expansion bay height (400 mm) 4100-2144 Power Distribution Module (PDM) Rack Mount Kit, order PDM separately per system voltage, one required per cabinet rack Power Distribution Modules (Not required for 4009 TPS Cabinets 2975-9229 and 2975-9230) Model Voltage Description 4100-0634 120 VAC Power Distribution Module (PDM); select per system voltage; 4100-0635 220/230/240 VAC one required per 4100ES box or cabinet rack Miscellaneous Accessories Model Description 4100-9856 Canadian French Appliqué Kit, for 1, 2, or 3 bay sizes 4100-9857 4100ES Appliqué Retrofit Kit, for 1, 2, or 3 bay sizes; use to identify 4IOOES features when new door is not used; included with Master Controller Upgrade kits as detailed on data sheet S4100-0031 4100-9835 Termination and Address Label Kit, for module marking NOTE: One kit is supplied for each cabinet; order this if required for additional field module installation 4100-9837 Green LED Power-on Indicator Kit, required for ULC Mounts using knockout provided in solid door listing of MINIPLEX transponder 2975-9813 Platinum semi-flush box trim 1-7/16" (37 mm) wide, four corners and trim pieces for top, bottom, and sides 2975-9812 Red semi-flush box trim S S Battery Reference Model Capacity 2081-9272 6.2 Ah 2081-9274 10Ah 2081-9288 12.7 Ah 2081-9275 18 Ah Model I Capacity I Battery Notes 2081-9287 I 25 Ah I Sealed lead-acid batteries, 12 VDC each; two required per 2081-9276 I 33 Ah battery location. Battery selection is required if batteries are internal. 2081-9296 50 Ah I Select one size per battery set I Refer to data sheet S2081-0006 for battery details. Battery Accessories Model Description 4100-0650 Battery Shelf, required for 50 Ah batteries 4100-5128 Battery Distribution Terminal Block, mounts to side of box, required for all close-nippled cabinets unless cabinet receives all power from power supplies and batteries located in the adjacent cabinet Additional Data Sheet Reference Subject 4100ES Basic Panel Modules and Accessories Data Sheet S4100-0031 Subject Network Display Unit (NDU) Data Sheet S4100-0036 LED/Switch Modules S4100-0032 Remote Annunciators S4100-0038 4100ES Audio/Phone Modules S4100-0034 InfoAlarm Command Center S4100-0045 MINIPLEX Transponders S4100-0035 Remote Battery Charger S4081-0002 2 S4100-0037-10 10/2011 S Front view, box outline without door Side view with door attached I Door thickness, 4-3/4 (121 mm) 3 Bay height = L 56(1422mm) Knockout screw/nail holes (for semi-flush mounting) 2 Bay height = 40" (1016 mm) Exposed cabinet for semi-flush mounting 1-3/8" (35 mm) minimum Wall board reference for semi-flush mounting, 6" stud 1 Bay height= 22" (559 mm) S NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. For additional installation information refer to Installation Instructions 579-117. S Doors can be hinged left or right I I I 4 24(610mm) Exposed door and cabinet for semi-flush mounting 6-1/8" (156 mm) minimum fiud alignment markers, each side [6" stud) Optional semi-flush trim kit reference 4" stud I Li-. 6-29/32" I (175mm) (296 mm) __________ Box width 16-1/8" (410 mm) iij Box depth =f4__7. (178 13-5/8" (346 mm) - I [1 I F TrueAlert Addressable Power Supply mounts here: 4100-5120, 120 VAC, US 4100-5121, 120 VAC, Canada 4100-5122, 220-240 VAC, 50/60 Hz, International panel size = AC power LED 13"Wx9" H (330 mm x229 mm) ----------------'__i_ ---v I Battery Area, 12.7Ah maximum, AC input terminal block I , Noconduitor wiringinthisarea 3 © 4009-9813 Transponder 16 Interface Card Knockouts are (406 mm) (TIC) mounts located on top here and both sides Door shown for reference S4100-0037-10 10/2011 H S [11.] i.]!iTT t[I1(1iN S Front View Side View Rear View Cabinet Rack Specifications (refer to Installation Instructions 579-229 for additional details) Type Upright cabinet rack for exclusive use with Simplex 4100ES Fire Alarm Products Supplier Order from Bud Industries Inc. (www.budind.com) Model Number 45964 Height Outside Dimensions Width Depth 69-7/8" (1775 mm) 24-1/16(611 mm) 22" (559 mm) Color Gray texture Panel Spate Width 19" E.I.A. (483 mm) Front Door Surface mount with 1/8" thick (3.18 mm) smoke gray polycarbonate, locked with Simplex B" key, hinged on left of cabinet Rear Door Ventilated top and bottom, locked with Simplex "B" key Sides Side panels are removable from the inside for rack-to-rack mounting Bottom Pan attached for battery mounting Levelers Includes 4 stem levelers on bottom TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. BSi i-n I EX Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4100-0037-10 10/2011 www.simplexgiinnell.com 02011 Tyco F'pe Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:0251 Page 1 of 4 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SimplexlOo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4100-9111, -9112, -9113, -9114, -9115, -9116, -9121, -9122, -9131, -9132, -9133, -9211,-9212,-9213,-9222,-9230,-9311,-9312,-9313,-9314,-9315,-9316,-9331,-9332, -9511, -9512, -9513, -9600, -9601 and -9602 fire alarm control units. Power limited, automatic, manual, local, auxiliary, remote station, proprietary and central station, process monitoring, smoke control system, smoke detector monitor, emergency communication and relocation, waterflow and sprinkler supervisory service. Suitable for releasing device service. Models 4100-9111,-9112,-9113,-9114,9115,-9116,-9121,-9122,-9211,-9212,-9213, -9222, -9311, -9312, -9313, -9314, -9511, -9512 and -9513 suitable for mass notification system as an autonomous control unit. The network display units are suitable for mass notification system system as a central control station. The remote annunciators are suitable for mass noticication system system as a local operating console. Refer to listee's data sheet for detailed product description and operational considerations. System components: • 4100-7101, -7104, -7113, -7115: Master Controller Assembly 4100-7105: Redundant Master Controller Assembly 4100-7150, -7151, -7152-7154-7156, -9833: Master Controller Replacements 4100-5005, -5015: 8-Point Class A IDC Module 4100-1291: Remote Unit Interface Module 4100-3102,-9812: MAPNET II Module 4100-3103: MAPNETIIDNET Isolator Module 4100-6038 RS-23212120: Communication Module 4100-6014-6078: Modular Network Interface Module 4100-1293: Printer 4100-6052-6080: Event Reporting DACT 41006053: Point reporting DACT 4100-6067: Contact Closure DACT 4100-6031, -6032, -9827, -9828: City Module 4100-2300,-2320: Expansion Bay 2975-9408 thru -9412: Backbox 2975-9438 thru -9440: Backbox 4100-2101 thru -2103, -2121 thru -2123: Glass Door and Retainer 4100-2104 thru -2106, -2124 thru -2126: Glass Door and Retainer *Rev. 09-05-14 gt This the listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S operational Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0251 Page 2 of 4 4100-2111 thru -2113, -2131 thru -2133: Solid Door 4100-2ll4 thru -2116, -2134 thru -2136: Solid Door 2975-9422 thru -9426, -9428, -9429: Enclosure 2975-9431, -9432: Enclosure 2975-9441 thru -9452: Enclosure 4100-0633, -6034: Tamper switch 4100-9141-9142-9151-9152-9241 thru -9246-9342-9352-9542 Network Display Unit 4100-6030,-6055: Service Modem 4100-5101, -5102, -5103: Expansion Power Supply 4100-5111, -5112, -5113: System Power Supply 4100-5125, -5126, -5127: Remote Power Supply 4100-1288,-1289: LED/Switch Controller 4100-1275 thru -1287, -1295, -1299: LED/Switch Module 4100-1300, -1301, -1302: LED/Switch Module 4100-1290 24: Point Graphic I/O Module 4100-9607-9609-9610, -9611-9612-9614-9615 Remote Annunciator 4100-1292: Remote LCD Display 4100-3115: XA Loop Interface Module 4100-3101-3104, -3105, -3106, 3107,3108,*3109,*3110,*3111,9811 IDNETModule 4100-9116: Addressable IDNET Isolator 4090-9117: Addressable Power Isolator 4100-9643: Utility Cabinet 4100-0634, -0635: Power Distribution Module 4100-5152, -5153, -5154, 5155: Auxiliary Power Supply 4100-6033, -9829: Alarm Relay Card 4100-3201, -3202-3203-3204-3206: Auxiliary Relay Modules 4100-0620: Basic Transponder Interface Card 4100-6043, -6044: Converter 4100-6045: Decoder Module 4100-6054: Fiber Optic Driver 4100-5115: Expansion NAC 4100-9816: Master Clock Interface 4100-6048: VESDA Interface 4100-5311,-5313,-5325,-5327: Extended Power Supply 4100-6103: Dual Class A Isolator 4100-5120, -5121, -5122: True Alert Power Supply 4081-9306, -9308: Expansion Battery Charger 4100-2140: Rack Mount Bay Mounting Kit 4100-2144: Rack Mount PDM Mounting Kit 4100-0156: Eight Volt Converter 4100-0625: Local Mode Transponder Interface Card 4601-9100, -9108,-9109,-9110,-9111 Local Mode Controller 4100-0623: Basic-Network Transponder Interface Card 4100-0621, -0622, -1341 :Audio Riser Module 4100-6036, -6037-6101-6102: Physical Bridge Assembly *Rev. 09-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S [I Listing No. 7165-0026:0251 Page 3 of 4 4100-9849, -9863: TCP/IP Physical Bridge Assembly (Style 4) 4100-9850, -9864: TCP/IP Physical Bridge Assembly (Style 7) 4100-6056: Wired Media Card 4100-6057: Fiber Optic Media Card 4100-9620: Analog Audio Expansion Bay 4100-9621 : Digital Audio Expansion Bay 4100-1210: Analog Audio Controller Card 4100-1211, -1311: Digital Audio Controller Card 4100-1212 thru -1225, 1261, -1262 Analog Audio Amplifier 4100-1312 thru -1325, -1361, -1362 Analog Audio Amplifier 4100-1226 thru -1239, 1263, -1264 Digital Audio Amplifier 4100-1326 thru -1339, -1363, -1364 Digital Audio Amplifier 4100-1240: Audio Input Option Card 4100-1241, -1242: Message Expansion Card 4100-1243,-1244: Microphone Module 4100-1245, -1248, -1266: Amplifier Expansion NAC 4100-1246, -1249, -1267 : Amplifier Class A Adapter 4100-1252, thru -1255 Audio Operator Interface Module 4100-1270: Master Telephone Assembly 4100-1271: Remote Telephone 4100-1272: Expansion Phone Card 4100-1273 : Telephone Class A Adapter 4100-5116: Expansion Signal Card 4100-1259, -1260, -1268: Constant Supervision NAC Modules 4100-1265: Degrade Fail-Safe Microphone Module 4100-6068: TFX Interface Module 4100-6072, 6073, 6074, 6075: Fiber Optic Modem S 4100-9842: Fiber Modem Audio Expansion Board 4100-9901 thru -9926, -9930 thru -9939Retro-fit Kits 4100-7153,-7155: Display Replacement 4100-9401, -9402, -9441, -9442: Remote User Interface 4100-0640: FUI Controller Memory Add-on Module 4100-7157: Expanded Memory CPU Card 4100-6065: BMUX Communication Card 2081-9046: Coil Supervision Module 4100-6066: TFX Loop Card 4100-5130: TFX Voltage Regulator Module 4100-1340: TFX Audio Interface Module 4100-1297 : TFX Phone Card 4100-1298: TFX Master Telephone with Phone Card 4100-6069: BACpac Ethernet Module 4100-1274: Microphone Multiplex Module 4100-6047: Building Network Interface Card 4190-6104: Remote Service Gateway RATING: 120, 220, 240 VAC primary; 24 VDC secondary *Rev. 09-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0251 Page 4 of 4 INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model/catalog number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units suitable for use with separately listed compatible initiating and indicating devices. Also Suitable for high-rise applications. The control unit is compatible with the Model 4090-9007Signal Individual Addressable Module (CSFM Listing No. 7165-0026:318). These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification feature (delay of the fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Combined from 7170-0026:250 . *Rev. 09-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 3O,2017 S Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ®Sim plEx S Fire Alarm Control Panel Accessories System Batteries, Sealed Lead-Acid; with Applications Reference for Battery Cabinets, and Battery Cabinets with Charger IT1UIt*I Rechargeable, sealed lead-acid batteries: Lead-calcium grid structure with immobilized electrolyte in absorbent separator Low maintenance with no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover with high reliability dual seal construction UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size Larger batteries, up to 110 Ah, mount in external battery cabinets with models available with internal chargers Battery cabinets with chargers: Battery cabinets with charger communicate with their connected fire alarm control panel and are available for 4100ES/4010ES/4100U Series and 4010 Series panels I44.111151 5 Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. Where required, external battery cabinets can be close-nippled to the control panel to house larger batteries with battery chargers available in some battery cabinet sizes. Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The is preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets Remote Battery Cabinets are Available for Larger Battery Requirements I:.fl1Yt1IIUFi7Ij Shipping. Sealed lead-acid batteries are shipped via ground or sea transportation only. They are not shipped via air. Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. Seismic Activity Applications. Battery brackets are available for systems tested for compliance with specific batteries. Please refer to data sheet S2081-0019 for details. * Refer to details on page 4 and to the referenced individual product data sheets for agency listing status of battery cabinets and chargers. The batteries detailed in this document meet the requirements of UL ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact your local Simplex product supplier for proper battery selection per system requirements. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S2081-0006-21 12/2014 N Battery Construction Reference Actual appearance will vary with battery size. Sealed outer cover Quick connect or post type terminal Vent h ore negative, red for positive Potting material, black for (type varies with battery size) (polarity is also clearly marked with + and -) Pressure relief valve Inner Absorbent separator used to immobilize electrolyte Semi-permeable Lead-calcium grids / membrane separator Cell group Cell case (high impact polystyrene) Battery Size Specifications B Model Battery 0 e Capacity® 20 Hour width* Depth* ep Height with Approximate Discharge Rate Terminals Weight* 2081-9272 6.2 Ah 6-1/8" (156 mm) 2-5/8"(67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 Ah (153 mm) 4-1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah 6" (153 mm) (102 mm) 4" (102 mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) (127 mm) (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8" (86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 ('square" case, 33 Ah 7-3/4" (197 mm) 5-1/4" (133 mm) 6-3/4" (171 mm) 26.5 lbs (12 kg) use for new 2081-9296 50 Ah 9" (229 mm) 5-1/2" (140 mm) 8-7/8" (225 mm) 41.8 lbs (19 kg) 2081-9279 110 Ah 11-3/16" (284 mm) 10-1/2" (267 mm) 9" (230 mm) 82 Lbs (37 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the tables on page 3 for mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output, these batteries are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. General Battery Specifications Nominal Voltage Rating 12 Volts per battery Discharge Rating 20 Hour Rate Typical Charge/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60" F to 90° F (15.6°C to 32.2" C) 2 S2081-0006-21 12/2014 S S [I 5 NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Battery Model Capacity Simplex Control Panel Model Series (see legend and notes below) 4003EC 4004R 4007ES & 4005 4006A 4008 4009 (all models) 4010 401 DES 4100ESI 4100U 4100 & 4120 (2, 4 or 6-Unit) 2081-9272 6.2 Ah 2081-9274 10 Ah 1 1 1 1 1 1 1 1 1 2081-9288 12.7 Ah 2081-9275 18 Ah Ext Note 3 1 Ext Ext Note 2 2081-9287 25 Ah Ext Ext NA / 1 1 1 2081-927 1 rectangular 33 Ah Ex tANote Ext Ext NA NA Note 3 / / Ext 2081-9276 'square" 33 Ah Ext Ext NA NA Note 3 2081-9296 50 Ah NA NA 1 NA 1 NA Note 3 Note 6 2 or 3 bay Ext 2081-9279 110 Ah Requires external battery cabinet, compatible with 4100ES, 4010ES, 4100, and 4120 Series only I = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 NA = Not applicable/not compatible NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. S 4. Some control panel models are listed for battery replacement reference only. 5. For 2 bay international applications only, 50 Ah batteries will fit in the cabinet. I External Battery Cabinet Compatibility Reference Battery Cabinets without Chargers (connects to charger in panel) Battery Cabinet Panel Compatibility - 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 18 Ah* 25 Ah Rectangular 33 Ah Square 33Ah 50 Ah 110 Ah 2081-9280 4100ES, 4O1OES, NA NA NA NA NA / 4100U, and 4100+ 2081-9281 multiple 1 1 1 / 1 NA 2081-9282 4009-9801 multiple I 1" NA NA NA NA 4009-9802 multiple I NA- I NA NA NA Battery Cabinets with Chargers 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 Cabinet Panel Compatibility 18 Ah 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah 4081-9301 4004R and 4010 1 1 1 1 / NA 4081-9302 4081-9306 4100ES, 4O1OES, NA NA NA NA / I 4081-9308 and 4100U * Batteries smaller than those listed are normally mounted in the product cabinet ** 25 Ah capacity was effective as of 7/2005. S 1= Can be placed in the respective equipment cabinet NA = Not applicable/not compatible S2081-0006-21 12/2014 External Battery Cabinet Specification Reference Battery Cabinets Without Chargers; Shallow Design with Front Door Model Color Listings Description Dimensions 2081-9281 Beige UL and FM 2-Unit, 4100 style cabinet without charger; with locking solid door and battery shelf, primarily for use with 50 Ah 25-3/4" 20-3/4 H 6-3/4" D (654 mm x 527 mm x 171 mm) 2081 -9282 Red batteries Intended for use with 4003EC systems, for up to 33 Ah 9-1/2" H x 24" W x 9" D 4003-9860 Beige Multiple batteries (refer to 4003EC data sheet S4003-0002) (241 mm x 610 mm x 229 mm) 40099801* Beige UL and For up to 25 Ah I External battery cabinet without charger, 16-1/4" W X 13-1/2" H X 53/4" D FM batteries* I with locking solid door and battery harness; for close-nippled mounting to (413 mm x 343 mm x 146 mm)* For up to 33 Ah 25-3/4" W 20-3/4" H x 4-1/8" D 4009-9802 Beige UL batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm) * Depth increased for 25 Ah batteries effective 7/2005. Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4061-0001) Model Color Input Voltage Description Dimensions Battery cabinet with charger for the 4010 and 4081-9301 Beige 4004R fire alarm control panel; for up to 50 Ah 22-1/2"Wx16-314"Hx8-3/8" D 120 VAC batteries; with front door (572 mm x 425 mm x 213 mm) 4081-9302 1 Red Listings include: UL, ULC, FM; CSFM, and MEA (NYC), see data sheet for details Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers (refer to data sheet S2081-0012) Model & Color Cabinet Description Compatible Charger Description Dimensions Listings Chargers 4010-9xxx 4010ES Main System Supply Series (MSS) 4100-9xxx 4100ES/4100U System Power Series I Supplies (SPS) Battery cabinet for 4100-5111 2081-9279, 110 Ah 4100-5112 4100E5/4100U Additional SPS 2081-9280 batteries; includes 4100-5113 Listings 80A battery fuse, 4100-5125 26-1/2" W 12" H x 12" D include: UL Red terminals and 4100-5126 4100E5/4100U Remote Power (673 mm x 305 mm x 305 mm) and CSFM battery connection 4100-5127 Supply (RPS) cables; see data sheet for details 4100-5120 4100ES/41001-1 TrueAlert 4100-5121 Addressable Power Supply (TPS) 4100-5122 4100-0104 4100-0114 4100 Legacy power supplies 4100ES14010ES14100U Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted power supply charger; refer to data sheet S4081-0002) Model Color Input Voltage Description Dimensions Battery cabinet with charger for up to 110 Ah 4081-9306 Red 120 VAC batteries; NOTE: Required for ULC listed charging of 27-7/8" W 13-1/2" H x 14-5/8" D 220/230/240 VAC, 110 Ah batteries; Listings include: UL, ULC, FM, (708 mm x 343 mm x 371 mm) 4081-9308 Red CSFM, and MEA (NYC), see data sheet for multi-tapped details 4100-9837 Green LED Power-on Indicator Kit, required for ULC listing, mounts above access panel using knockout provided TYCO, SiMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited B®S i in p1 EX Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S2081-0006-21 12/2014 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. - S S S S S BSim plEx UL, ULC, CSFM Listed; FM Approved * I11!I(*I Individually addressable manual fire alarm stations with: Power and data supplied via IDNet or MAPNET II addressable communications using a single wire pair Operation that complies with ADA requirements Visible LED indicator that flashes during communications and is on steady when the station has been activated The NO GRIP Single Action Station and Retrofit Kit are available with a more easily operated pull lever for applications where anticipated users may find the standard station lever difficult to activate Pull lever that protrudes when alarmed Break-rod supplied (use is optional) Models are available with single or double action (breakglass or push) operation UL listed to Standard 38 Compatible with the following Simplex® control panels: Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, 4100U, 4020, 4100, and 4120 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Compact construction: Electronics module enclosure minimizes dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections Tamper resistant reset key lock (keyed same as Simplex fire alarm cabinets) Multiple mounting options: Surface or semi-flush with standard boxes or matching Simplex boxes Flush mount adapter kit Adapters are available for retrofitting to commonly available existing boxes Jsrrintir The Simplex addressable manual station combines the familiar Simplex manual station housing with a compact communication module that is easily installed to satisfy demanding applications. Its integral individual addressable module (JAM) constantly monitors status and communicates changes to the connected control panel via IDNet or MAPNET II communications wiring. * Refer to page 2 for specific model listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7150-0026:224 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet or MAPNET II Communicating Devices Addressable Manual Stations 71111 4099-9021 4099-9805 4099-9004 NO GRIP NO GRIP Single action Single action Retrofit kit [.]v PULL DOWN KEY 77-1~ op ERATED ONLY 4099-9005 4099-9006 With 2099-9828 Breakglass Push Institutional Cover kit DnPratk Activation of the 4099-9004 single action manual station requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod (visible below the pull lever, use is optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Single Action NO GRIP Station 4099-9021. For applications such as California Building Code, Title 24, which requires "Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist" the model 4099-9021 station provides a more easily operated pull lever compared to standard stations. Retrofit of existing stations is available using the 4099-9805 Retrofit kit. Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. Double Action Stations (Push Type) require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action station. Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. (If the break- rod is used, it must be replaced.) Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. S4099-0005 10/2014 Addressable Manual Stations, Red Housing with White Letters and White Pull Lever Model 4099-9004 Description Single Action, English Housing FIRE ALARM Pull Lever PULL DOWN Listings UL, ULC, FM, CSFM 4099-9004CB Single Action, Bilingual English and French FEU FIRE TIREZ PULL ULC 4099-9004CF Single Action, French ALARME FEU ABAISSEZ 4099-9004P0 Single Action, Portuguese FOGO ALARME PUXE UL FM 4099-90045P Single Action, Spanish ALARMA FUEGO JALE 4099-9005 Double Action, Breakglass operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM 4099-9005P0 Double Action, Breakglass operation, Portuguese FOGO ALARME PUXE UL FM 4099-90055P Double Action, Breakglass operation, Spanish ALARMA FUEGO JALE 4099-9006 Double Action, Push operation, English FIRE ALARM PUSH PULL DOWN UL, ULC, FM, CSFM 4099-9006P0 Double Action, Push operation, Portuguese FOGO ALARME EMPURRE PUXE 4099-90065P Double Action, Push operation, Spanish ALARMA FUEGO EMPUJE JALE UL FM 4099-9021 Single Action NO GRIP operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM Accessories (refer to pages 3 and 4 for details) Model Description Model Description 2975-9022 Cast aluminum surface mount box, red 2099-9803 Replacement breakglass 2975-9178 Surface mount steel box, red 2099-9804 Replacement break-rod 2099-9813 Semi-flush trim plate for double gang switch 2099-9828 Institutional cover kit for field installation on 4099-9004; box, red Note: Covers LED indicator 2099-9819 Flush mount adapter kit, black 2099-9814 Surface trim plate for Wiremold box V5744-2, red ---dl 2099-9820 Flush mount adapter kit, beige 4099-9805 Retrofit Kit for field conversion of a single action station to a NO GRIP station; refer to Installation Instructions I 579-1007 for details Specifications (refer to Installation Instructions 579-1135 for additional information) Power and Communications IDNet or MAPNET II communications, 1 address per station Address Means DIP switch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) UL Listed Temperature Range 32° to 120° F (0° to 49" C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5"H x3%"Wx 1" D(127 mmx95 mmx25 mm) FIRM mwmillarmilm=. 4 Square Box Mount— 4" (102 mm) square box, 2 1/8" (54 mm) minimum depth, RACO #231 or equal (supplied by others) Mount flush or with ( 1/16"(2 mm) -i Single Gang Box Mount Single gang box, 2 1/2" deep fi ___ ________ r maximum extension DO NOT RECESS ---- 4" Square box wit over late) (64 mm), RACO #500 or equal 01 _ (supplied by others) _ ___-, FIRE_J[ALARM] Station7 side view H Single gang cover plate, 3/4" PULL DOWN ybne (19 mm) extension, RACO #773 LED or equal (supphed by othem) Indicator- Wall suace SimpIE] Semi-Flush Mount Side View 2 S4099-0005 10/2014 C S S S Addressable Manual Stations Surface Mounting Preferred Mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown in the illustration to the right. Additional Mounting Reference. Refer to page 4 for Wiremold box mounting compatibility. 2975-9178 Box 5-3116 Hx4'Wx2-3116'D (132 mm 102 mm x 56 mm) (ordered separately) \ Knockouts located top and bottom 2975-9022 Cast Box 5" H x 3-7/8W x 2-3/16" D (127 mm x 98 mm x 56 mm) (ordered separately) 0 FIRE](4~ [ALARM PULL DOWN Access for 3/4" threaded 5, conduit located top and bottom (127 mm) _L I [simplEx] 1,' (25.4 mm) i 3-3/4 (95 mm) 4099 Series Addressable Manual Station Surface Mount Side View with Internal Detail 1-1/4" (32 mm) Field wiring (shown for reference) Address setting under resealable label (accessible with cover open) Station cover hinges open for installation access Simplex 2975-9178 box (shown for reference) - Switch wiring (prewired) L1IrUTT1 iit*I Refer to NFPA 72, the National Fire Alarm and Signaling Code, and all applicable local codes for complete requirements for manual stations. The following summarizes the basic requirements. Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible. Mounting shall be with the operable part not less than 42 in (1.07 m) and not more than 48 in (1.22 m) above floor level. At least one station shall be provided on each floor. Additional stations shall be provided to obtain a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building. When manual station coverage appears limited in any way, additional stations should be installed. 3 S4099-0005 10/2014 n Addressable Manual Station, Additional Mounting Information For retrofit and new installations, additional compatible mounting boxes and the required adapter plates are shown in the illustration to the right. 2099-9814 Surface trim for Wiremold box 5-1/8" H x 5"W (130 mm x 127 mm) Wiremold receptacle box model V5744-2 (supplied by others) Two gang switch box, each 3" Hx2"Wx2-3/4" D (76 mm x 51 mm x 70 mm) (supplied by others) S Addressable station • 1 2099-9813 Semi-flush trim for 2 gang switch box, 6" H x 4-1/2' W (152 mm 114 mm) Addressable Manual Station, Flush Mounting Information Flush mount adapter kit 2099-9819, Black 2099-9820, Beige S Box must be recessed into wall 1" to 1-1/8" (25.4 mm to 29 mm) 8" (203 mm) 6" (152 mm) rHole cutout must be a ninimum of 6" H by5" W LI (152 mm by 127 mm) T Wall 4-3/4" (121 mm) surface 4 6-3/4" (171 mm) 0 :0 0 4-11/16" (119 mm) square box, 2-1/8" (54 mm) minimum depth (by others) Front View Side View TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). Lexan is a trademark of the General Electric Co. Wiremold is a trademark of the Wiremold Company. S S- I Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4099-0005 10/2014 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0026:0224 Page 1 of 1 CATEGORY: 7150— FIRE ALARM PULL BOXES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4099-9001, -9002, -9003, *9004 *.9005 *.90069010 -9011, -9012, *..9013 *9014 w.9015 -9020, and *.9021 non-coded addressable manual pull stations. Model 4099-9805 Conversion Kit, Models 4099-9001, *9004 -9010, *9013 -9020 and *.9021 are single action stations. Models 4099*9005, -9011 and *9014 are breakglass stations. Models 4099-9003, *9006 -9012 and *9015 include a push bar which must be punched in before being able to grab and pull down the actuating handle. Model 4099-9805 is a retrofit Kit handle for field conversion of a single action station to a NO GRIP station. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. 5 APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. *Rev. 03-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct S operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S BSim.plEx UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* I1titt*i TrueAlarm analog sensing provides: Digital transmission of analog sensor values via IDNet or "NET II two-wire communications For use with the following Simplex® products: 4007ES, 4010, 4010ES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET 11 operation Fire alarm control panel provides: Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide: Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Listed to UL 521 and ULC-5530 General features: Operation is for ceiling or wall mounting Listed to UL 268 and ULC-S529 Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted Designed for EMT compatibility Magnetic test feature is provided Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator Additional base reference: For isolator bases, refer to data sheet S4098-0025 For sounder bases, refer to data sheet S4098-0028 For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. TrueAlarm Analog Sensing TrueAlarm Analog Sensors - Photoelectric and Heat; Standard Bases and Accessories S 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. S4098-0019-20 1/2015 TrueA!arm Sensor Bases and Accessories Sensor Base Features. Base mounted address selection: Address remains with its programmed location Accessible from front (DIP switch under sensor) General features: Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test 4098-9792, Standard Sensor Base 4098-9789, Sensor Base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases (not compatible with 2120 CDT): 4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC 4098-9780, 2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required Supervised relay operation is programmable and can be manually operated from control panel Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) 1i-r- f•]f 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay: SPDT dry contacts, power limited rating of 2 A @ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box (shown in illustration to right) AM 13 Simplex IRI4.Iii1tT1 TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. lVlUUi1LlF1y rwlereliL.e Electrical Box Requirements: (boxes are by others) Withoutr gla in the box: 4' octagonal or 4 square, 1-1/2" deep; single gang, 2" deep With relay : 4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Surface mount reference-. ILPEN io 1-1/2" (38 mm) minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 2098-9737 Supervised Relay 4098-9822 Relay (mounts (mounts in base electrical box or in base electrical box) remotely) FRelay S,ze \2-1/2" X 3.75 in 3)(64 mm X 38 mm X 25.4 mm) 4098.9860 Supervised. Relay (mounts in base electrical box or remotely; 2-3/8" X 1-1/4" X 11/32 (1 in 3)(60.4 mm X 31.8 mm X 8.6 mm) t~nf NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. 6-3/8" (162 mm) •1 t 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes (6.4 mm) an uare flush box I" 4-7/8" (124 mm) 15/16" i. (24 mm 0 TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 S S4098-0019-20 1/2015 TrueAlarm Sensors S I1!i(-1 Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed Temperature Setting 135°F 60ftx60ft 20ftx20ft(6.lm) for fixed (57.2° C) (18.3 m) temperature only; RTI = Quick 50 ft 50 ft (15.2 m) for fixed 155° F 40 ft X 40 It temperature with either rate-of-rise (68° C) (12.2 m) selection; RTI = Ultra Fast Smoke Sensors: Photoelectric technology sensing 3600 smoke entry for optimum response Built-in insect screens E11MINFAEUIT61 Me- MWITT "S TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power S smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* 4098.973 Ht Snsnr TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° Q. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. .1 H 4-7/8' (124 mm) LED status indicator / 2-3/8" (60 mm) 4098-9733 Heat Sensor with Base The sensor head design provides 360° smoke entry for WARNING: In most fires, hazardous levels of smoke I optimum response to smoke from any direction. Due to its and toxic gas can build up before a heat detection photoelectric operation, air velocity is not normally a device would initiate an alarm. In cases where Life factor, except for impact on area smoke flow. Safety is a factor, the use of smoke detection is highly I recommended. I S f 4 4-7/8" (124 mm) LED status indicator 2-1/8' (54 mm) I 1111 I II liii II Al 1 4098-9714 Photoelectric Sensor with Base r1Irtt1(1sI*I Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0019-20 1/2015 \\\Iarri ii fl061Th! IFITSTThI lrueAlarm Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model I Description I Compatibility I Mounting Requirements 4098-9792 Standard Sensor Base No options 4" octagonal or 4" square box, 1-1/2" mm. depth; or single gang box, 2" mm. depth Sensor Base with connections for 2098-9808 Remote Alarm Indicator or 4098-9789 Remote LED Alarm Indicator or 4098-9822 Unsupervised Relay 4" octagonal or 4" square box Unsupervised Relay li!: Box depth requirements depend on 4-Wire Sensor Supervised Relay 2098-9737 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 40989791** Base with connections for LED total wire count and wire size, refer to accessories list below for reference. Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay ** NOTE: 4098-9791 and 4098-9780 are NOT 2-Wire Sensor Supervised Relay 4098-9860 Supervised Remote Relay 4098-9780"" Base with connections for LED 2098-9808 Remote Alarm Indicator or compatible with the 2120 CDT Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay lrueAlarm Sensors Model Description Compatibility Mounting Requirements 4098-9714 Photoelectric Smoke Sensor Bases 4098-9792, 4098-9789, 4098-9733 Heat Sensor 4098-9791, and 4098-9780 Refer to base requirements lrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base For use with 4098-9791 base Remote Mounting requires 4" octagonal electrical box - or 4" square box, 1-1/2" minimum depth Base Mounting requires 4" octagonal 4098-9860 Supervised Relay, mounts remote or in base For use with 4098-9780 base electrical box - box, 2-1/8" deep with 1-1/2" extension ring 2098-9808 Remote Red LED Alarm Indicator on single Bases 4098-9789, 4098-9791, Single gang box, 1-1/2" minimum depth gang stainless steel plate and 4098-9780 4098-9822 Unsupervised Relay, tracks base LED status; Bases 4098-9789, 4098-9791, 4" octagonal box, 2-1/8" deep with 1-1/2" Note: Mounts only in base electrical box and 4098-9780 extension ring Bases 4098-9792, 4098-9789, Required for surface or semi-flush 4098-9832 Adapter Plate 4098-9791, and 4098-9780 mounted 4" square box and for surface mounted 4" octagonal box General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Operating Temperature Range 32" to 100" F (0° to 38" C) Operating Temperature with 4098-9733 Heat Sensor Range with 4098-9714 Smoke Sensor 32" to 122° F (0" to 50" C) 15" to 122° F (-9" to 50" C) Storage Temperature Range 0" F to 140" F (-18° C to 60° C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ftlmin (0-1220 rn/mm) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 1A, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power J Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current . Supplied from communications Alarm Current 13 mA from seoarate 24 VDC sulv TYCO, SiMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). B®S i rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4098-0019-20 1/2015 02015 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:0218 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4098-9714, -9714T5P, -9714TTP, -9754 -9754T5P, -9754TTP; G5A4098-9714, and -9754 analog photoelectric type smoke detectors. Units are intended for use with smoke detector bases Models 4098-9789 9789T5P, -97891TP, -9791, -9791T5P, -9791 TTP, -9792, -979215P, 979211P, -9793, 9793T5P, -9793TTP, -9794, -979415P,-9794TTP; G5A4098-9792, and -9793 (CSFM Listing No. 7300-0026:217). Models 4098-9714, -9714T5P and -9714T1P are listed for use with Models 4098-9750-9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:220) and Models 4098-9755, -9755T5P and -975511P duct detector units (CSFM Listing No. 3240-0026:241). Models 4098-9754, -9754T5P, -9754TTP; G5A4098-9754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (1350 F fixed temperature and 1200 F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's separately listed *compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 12-02-13 gt This listing is based upon technical data submitted by the the test results and/or other data but does not make an independent applicant. CSFM Fire Engineering staff has reviewed verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0026:0216 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Models 4098-9733, 4098-9733E, *40989734 *4098..9734E GSA4098-9733 or *GsA40989734 electric combination rate compensated, fixed temperature, and rate of rise heat detectors. Intended for use with *listees separately listed compatible detector bases. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 135°F and 155°F all models. 190°F (-9734 models only) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical/temperature ratings and UL label. APPROVAL: Listed as heat detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. S S *Rev. 02-18-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 30, 2017 Listing Expires June Authorized By: DAVID CASTILLO, Program Coordinator Fire EAgineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0217 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Models 4098-9780,-9780E, *9772 -9789, -9789E, 978915P, -9789TTP, -9791, -9791E, -9791 TSP, 979111P,-9792, -9792E, -9792T5P, 979211P, -9793, -9793E, -9793T5P, -97931TP, -9794, -9794TSP, -9794TTP, -9795, -9795T5P, -9795TTP, -9796, -979615P, -979611P; GSA4098-9780, -9792, -9793, -9795 and -9796 smoke detector bases. These bases act as an interlace between the sensor and the MAPNET controller. Bases are intended for use with the following units: Models 4098-9714 and G5A4098-9714 series photoelectric smoke detector (CSFM Listing No. 7272-0026:218); Model 4098-9717 ionization smoke detector (CSFM Listing No. 7271-0026:231); and Models 4098-9733, G5A4098-9733, *4098..9734 and *G5A4098.9734 heat detectors (CSFM Listing No. 7270-0026:216). Models 4098-9795, -9795TSP, -9795TTP, -9796, -9796T5P, -9796T1P; GSA4098-9795, and -9796 are only intended for use with Models 4098-9754 or GSA4098-9754 photoelectric smoke detector (CSFM Listing No.7272-0026:218). Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Models 4098-9794, -9794TSP, -97941TP, -9795, -9795T5P, -9795T1P, *9772 and G5A4098-9795 employ a sounder, which is also suitable for use as a fire alarm audible signaling device. These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. *Rev. 04-21-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RVC operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S £LSimpIEx Addressable Detection Products UL, ULC, CSFM Listed; Auto-Aligning Reflective Beam Smoke FM Approved* Detectors with IDNet Communications S S I11Ii j41 Auto-aligning reflective beam smoke detector system with on-board IDNet addressable communications: Compatible with Simplex® 4007ES, 4010ES, and 4100ES fire alarm control panels Simplex addressable beam smoke detectors add IDNet communications to the proven FireRay 5000 Series beam smoke detection system Communicates status information, and receives commands and sensitivity threshold selection from the host fire alarm control panel Photoelectric transmitter and receiver are combined in a single, compact housing: Connect up to two remote detector heads to one ground level controller An infrared beam is reflected from a matching prism with the reflected light analyzed by an on-board microprocessor Operating range covers 26 ft, 3 inches to 330 ft (8 m to 100 m) Modular design with easyfit mounting system and LASER assisted prism mounting provides convenient mounting and adjustment Auto-Align beam alignment operation conveniently rotates beam to align to the prism center during installation AutoOptimise operation automatically maintains alignment for reliable operation Listed to UL 268 and ULC-S529 On-board microprocessor controlled operation includes: Ground level system controller with LCD Operating voltage range of 14 to 36 VDC Easy setup and alignment with built-in electronic IJL/ULC obscuration acceptance test selectable from host control panel Automatic gain contrpl; contamination compensation, building shift compensation with control and monitoring of alignment motors, and ability to change delay to Fire and delay to Fault timings Host fire alarm control panel operations include: Sensitivity selection from 10% to 60% (35% default) Point type selection (fire, latched supervisory, or utility) and set Almost Dirty threshold Initiate obscuration test, Reset latched conditions, Enable/Disable, and control of beam head LED Host fire alarm control panel information received includes: Smoke status, controller-to-detector communications status, rapid obscuration status (beam blocked), self-alignment status, almost dirty, excessively dirty, and summary (general) trouble status Analog values for signal strength and compensation level (see page 2 for more information) Addressable Beam Detector Head Addressable Beam Control Station Applications: Large open areas such as warehouses, hotel atriums, industrial plants, and school gymnasiums Public areas where cosmetics are of prime importance and detector heads need to be small and unobtrusive (shopping malls, libraries, theaters, and churches) Optional Accessories: Detector: adjustment bracket, back box, and cover plate Controller back box Extended prism mounting options Convenient Installation and Alignment. Simplex addressable beam smoke detection provides the proven FireRay 5000 system features of auto-aligning infrared beam smoke detection combined with IDNet addressable communications. Once the detector head is installed using the easyjIt mounting system, an integral laser can be activated that is aligned along the optical path of the infrared beam, allowing the reflective prism to be quickly located. The Auto-Align beam alignment feature then allows the reflective prism to be located quickly and accurately. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7260-0026:377 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4098-0049-2 11/2014 191:1.163 11414 lei I of 1 -0 AutoOptimise Beam Alignment. The AutoOptimise beam alignment system automatically steers and maintains the beam in the optimum position for reliable performance. The signal is generated in the transmitter element and reflected by the prism back to the receiver element, then analyzed for the presence of smoke. The beam control station determines an alarm condition when the predetermined level is reached. Alarm threshold levels are set from the host fire alarm control panel. Time to Fire and time to Fault are set at the beam control station. Mounting Reference. The maximum distance of the Detector and Reflector from the ceiling must be 10% of the distance between floor and ceiling. Lateral detection may be up to 30 ft (9.144 m) on either side of the beam, providing a maximum total coverage area of up to 19,800 square feet (60 ft x 330 ft or 18.29 mx 100 m). Communications to the host control panel. The host fire alarm control panel receives status and numerical information from the beam controller to allow remote investigation of the beam head(s). The beam controller receives commands and-the Smoke and Almost Dirty threshold levels are set from the host control panel. Numerical information received includes: Signal Strength in % (to compare to alarm threshold level set by host control panel) and Compensation Level (indication of beam status and dirt accumulation). Application Note. Reflective beam smoke detectors may not be suitable for areas with highly reflective surfaces. Separate transmitter/receiver models may be required. Refer to NFPA 72 and contact your Simplex product representative for additional applications guidance. Refer to the Installation Instructions supplied with the product and to NFPA 72, the National Fire and Signaling Code for additional installation guidance. Accessory Reference (not shown to scale) - L- - J, ••/f( j_./,•. j I Beam Detector on - 5000-005 Alignment Bracket Beam Detector on 5000-011 Uni-Box 23901 Prism Reflector One Prism on Four Prisms on 5000-006 Mounting Bracket 5000-006 Mounting Bracket 5000-008 Single Prism Adapter 5000-201 Adjustment Bracket on a 5000-005 Alignment Bracket 5000-007 Four Prism Adapter on 5000-005 Alignment Bracket S4098-0049-2 11/2014 N S [1 Product Selection and Ordering Information Addressable Beam Detector Selection Model I Description IDNet Communications Addressable Reflective Auto Align Beam Controller Smoke Detector System; 4098-9019 Includes: one 4098-9020 controller, one 5000-031 detector head, and Head one 23901 prism reflector; For control of up to two detector heads Prism IDNet Communications Addressable Reflective Auto Align Beam Smoke Detector 4098-9020 Controller only, for upgrade or replacement; select detector head(s) and prism reflector(s) separately as required; Beam Detector Heads, Prisms, and Accessories Ordering Number* Description Dimensions 5000-031 Additional Detector Head and Prism, select up to 1 additional head per 4098-9019 5 %2" H x 5 /33 D /16 " W x 5 %," System (135 mm x 134mm x 132 mm) 5000 Series Detector Uni-Box back box includes: hinged cover plate, conduit knock- 7 1h" square x 2 /16 D 5000-011 outs on all sides, captive screw lock on cover plate, universal back plate mounting (181 mm x 52 mm) holes, and cover plate mounting holes for optional 1000-018 wire cage; box may be (including cover plate) s surface or flush mounted 5000-012 Detector Cover Plate for mounting 5000 Series Detector to a double gang electrical 6 /16" square (164 mm) box, surface or flush mount with /16" lip (5 mm) 5000-005 Alignment Bracket for detector or prism, surface mount; pivots for accurate 5 %" square footprint x 2 /&' D alignment, order detector and prism parts separately (134 mm x 71 mm) 5000-201 Alignment Bracket for detector or prism, surface mount; provides 360° rotation plus 3 27,32 H x 3 2/32"W 1300 adjustment for accurate alignment, order detector and prism parts separately (98 mm x 99.5 mm) 5000-009 Controller Back Box, surface or flush mount; mounts to single gang, double gang, or 8 7A6" H x 7 '/,,"s" W x 1 3/4" D 4" square box for surface mounting (214 mm x 189 mm x 45 mm) 5000-010 Controller Back Box Semi-Flush Mount Trim Plate (for 5000-009 box) 10 5A6"Hx8 3/4"W (263 mm x 222 mm) 5000-006 Prism Wall Mount Bracket; mounts a single prism, for up to 160 ft (49 m); or four 11 /16 x 8 /16 x %" D prisms, for 160.ftto 330 ft (49 m to 100 m); prisms are ordered separately (284 mm x 211 mm x 13 mm) 5000-008 Single Prism Alignment Adapter, mounts on 5000-005 Alignment Bracket; order 4" square (102 mm) Prism and Alignment Bracket separately 5000-007 Four Prism Alignment Adapter, mounts on 5000-005 Alignment Bracket; order 8" square (204 mm) Prisms and 5000-005 Alignment Bracket separately 23901.01 Replacement Prism Reflector 5000-004 Long Range Prism Kit; provides three, 23901 Prisms for distances between 160 ft and 330 ft (50 m to 100 m) 5000-014 Ceiling Pendant Mounting Bracket 1000-018 Protective Wire Cage for 5000 Series Detector Heads 1000-019 1 Protective Wire Cage for 5000 Series Controllers * Internal Ordering Note: These products can be found in Job Design under Fire Fighting Enterprises, OP category OPFFE. ['f1TT1I fli u]TE'I 91flhIi Seconds User Prompt Crn,iens,Uo', 1.' vel (' ' lrjnsm. S 9'r 9're'gh f"r' I S -f'r - '---Ir r-ri .'"! •c 1i1 ±rL 13 large' no Threns,jd Fire lest I Oo,S,ollei -Si fl3S 0emr4c, Beam r Ern Delay St ;lgronr Lg S4098-0049-2 11/2014 Dimensions 9WHx7h"Wx2 13A6"D (235 mm x 200 mm x 71 mm 5%2"Hx5 5A6"Wx59/32" D (135 mm x 134 mm x 132 mm) 4 1/8" x 3 15/16 x %" D 05 mm x 100 mm x 9.5 mm) 9WHx7 7/."Wx2 13A6"D (235 mm x 200 mm x 71 mm) Specifications Mechanical and General Reference Housing Flame Retardant ABS; IP rating = IP54 Finish Light Grey/Black Simplex Addressable Interface and Host Control Panel Programming Instructions 579-1039; (Additional Operating and Installation Instructions are shipped with the product) Head and accessories reference Fire Fighting Enterprises (A Halma Group Company); website: www.ffeuk.com/ Electrical Input Voltage 14 to 36 VDC, supplied from agency listed fire alarm power supply Input Current 50 mA Power Wiring to Controller Terminal block connections; 18 to 14AWG (0.82 mm2 to 2.08 mm2) Wiring, Controller to Head 328 ft (100 m) maximum distance; use twisted wire pair; 18 to 16 AWG (1 mm to 1.5 mm2) Beam Optical Wavelength 850 nm Details Communications Compatibility Reference Reference (review for addition to installed systems) IDNet addressable communications; communications circuit is isolated from input power, and controller-to-head communications IDNet Communications Source Firmware/Revision 4100ES and 4010ES Control Panels System Firmware 2.02 or higher 4100ES System Power Supplies (SPS) Firmware 3.12.05 or higher 4010ES Main System Supply (MSS) Firmware 3.12.05 or higher Separate IDNet/IDNet+/IDNet 1+ modules Firmware 3.12.05 or higher IDNet communications PCC Chip 746-146 Revision 2.02.03 or higher 4007ES Compatible beginning with first release Addressing On-board DIP switch selects a base address to communicate with the local controller and the first beam detector head; for systems with two heads per controller, the next sequential address is automatically assigned Operating Specifications Selectable from 10% to 60%; with 35% as default (this is % of beam obscuration drop Sensitivity Threshold from 100%); desired value is selected at host fire alarm control panel and communicated via IDNet communications Operating Distance Range 26 ft, 3 inches to 330 ft (8 m to 100 m) Beam Status Indicators Multi-color LED on bottom front of beam detector head: Normal = Green; Alarm = Red; Fault (Trouble) = Yellow; LED flash is every 10 seconds Service Status Indicators One LED per detector, located under beam controller cover, indicates status of beam detector channel communications Point Types Fire, Latched Supervisory, or Utility, selected at host fire alarm control panel Trouble Conditions Communications fault rapid obscuration fault (blocked beam), excessively dirty, and summary trouble (other general troubles not detailed) UL Listed Temperature Range 32° F to 100° F (0° Cto 38° C) Operating Temperature Range -4° F to 131° F (-20° C to 55° C); for indoor use only Operating Humidity Range 0 to 93% RH, non-condensing TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). 0 B®S i rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4098-0049-2 11/2014 0 2014 Tyco Fire Protection Products. All rights reset-red All spec/lcations and other information shown were current as ofdocument revision date and are subject to change without notice. S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7260-0026:0377 Page 1 of 1 CATEGORY: 7260 -- SMOKE DETECTION SYSTEM-BEAM TYPE LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Model 4098-9019 Projected beam type smoke detector. Each unit is a transmitter/receiver, *Model 4098-9020 controller and reflector prism consisting of resistors, capacitors, diodes, photo diodes, LEDs, and an LCD display mounted on a printed wiring board inside an enclosure. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 14-36 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a projected beam type smoke detector for use with listee's Model 4010E5 (CSFM No. 7165-0026:0369), *4100ES (CSFM No. 7165-0026:0251), *4007ES (CSFM No. 7165-0026:0378) fire alarm control panel. Refer to listee's Installation Instruction Manual for details. S *Revised 3-25-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Multi-Application Peripherals IDNet and MAPNET II Communicating Devices, Individual Addressable Modules (lAMs) 4090-9001 Supervised [AM (shown approximately 3/4 size) 4090-9051 Supervised [AM (shown approximately 3/4 size) fl ri nti cm Individual addressable modules (lAMs) receive both power and communications from a two-wire MAPNET II or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. U.SiMPIEX S UL, ULC, CSFM Listed, FM Approved; MEA (NYC) Acceptance* Ik!I(*1 IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from JAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications For use in indoor locations up to 158° F (70° C) such as attic spaces or similar applications For use with following Simplex control panels: Model Series 4007ES, 4008, 4010, 4010ES, and 4I00ES fire alarm control panels for IDNet communications Model Series 4100/4100U/4100ES, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: Encapsulated design for extended exposure to high humidity (LED is not present on this model) Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterfiow switch (alarm) on same circuit using one point Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) UL listed to Standard 864 * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use— City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simples product supplier for the latest status. Listings and approvals under Simples Time Recorder Co. are the property of Tyco Fire Protection Products. S4090-0001-11 11/2014 nrtic Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not available with the 2120 CDT). [I1!lt] iii For use with IDNet communications only, these lAMs can provide quad-state sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is "T-sense.") With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be determined and communicated by a single addressable point. fl' \\ Model Description 4090-9001 Supervised lAM, mounted in thermoplastic housing with screw terminals; see applicable options below 4090-9051 1 Supervised lAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 1 For semi-flush mounted box 4090-9807 1 For surface mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, includes mounting screws; galvanized steel 4090-9810 Mounting bracket, mounts lAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No Description 4081-9004 733-886 16.8 kg), 1/2W Standard end-of-line resistor harness for N.O. contact supervision 4081-9003 I 733-896 14.7kQ,1/2W 4081-9005 I 733-984 1 1.8 k1, 1/2W Use for current limited monitoring applications S Specifications__- - Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per lAM Input Requirements Normally open, dry contacts Wire Connections - 4090-9001 4090-9051 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Reference Documents Installation Instructions Field Wiring Diagrams 574-331 for 4090-9001; 579-572 .for 4090-9151 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances Distance from [AM to Contacts 500 ft (152 m) maximum without protectors 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET If or 2500 ft (762 m) maximum from fire alarm control panel IDNet Communications 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical 4090-9001 Dimensions 4090-9051 1-9/16" W x 1-3/4" H xl-1/4"D(40mmx44mmx32mm) 1-9/16" W 1-9/16" H x 9/16" D (40 mm x 40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32° to 158" F (0° to 70° C); intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) 2 S4090-0001-11 11/2014 S 1 II I IIII li Ii II I I i "tit I 1111. S14-11 II I lI II I Ii fERfi4ii; 01 LED viewing port Mounting Information 4090-9001 IDNet Field wiring shown supervised lAM for reference S Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate 4-1/4" (108 mm) © II' Light pipe for © LED viewing [ISCONEGT POWER WSOG.NECT POWER [ EEFORE SERlCiNG EEFORE © © 2-1/2" ___ (64 mm) 4090-9806, Trim plate for semi-flush mounted box 2-13/16' No (72 mm) 4090-9807, Trim plate for surface mounted box 4090-9810 Mounting bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. 5 Optional Trim Plates and Mounting Bracket for Visible LED 2 S4090-0001-11 11/2014 4090-9051 Mounting Information Address setting is at rear of housing Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Single gang blank cover plate and S mounting screws (supplied by others) ®S i rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4090-0001-11 11/2014 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. S 4090-9002 IDNet Relay lAM Package (shown approximately 1/2 size) E1 Communications IDNet communications 1 address per device Relay lAM Power Supplied by IDNet communications Contact Ratings* (not rated for incandescent switching) Type Form C, SPDT 2 A @ 24 VDC, resistive from listed Power-Limited fire alarm 1 A @ 24 VDC, inductive supply Nonpower-Limited 0.5 A @ 120 VAC, resistive * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120 VAC loads may require RC networks or varistors, depending on device type. Refer to the installation instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4 %"H x 4 '/" W x 1 %" D (105 mm x 105 mm x 35 mm) Housing Material Black thermoplastic Mounting Plate Sheet metal, galvanized Temperature 32° to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) Installation 574-184 Instructions BSimplEx UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Multi-Application Peripherals IDNet Communicating Devices Model 4090-9002 Relay lAM IkuI4-1 Individual Addressable Relay Module (Relay lAM): IDNet addressable control for use with Simplex® fire alarm control panel models 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U A single addressable point provides control and status tracking of a Form "C" contact Low power latching relay design allows IDNet communications to supply both data and module power Relay is set to OFF on initial power up and upon loss of IDNet communications Compact, sealed construction: Enclosed design minimizes dust infiltration Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 "/16" 1/ (119 mm) square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation UL listed to Standard 864 IIi*i.iii11t1 IDNet Relay lAMs allow fire alarm control panels to control a remotely located Form "C" contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring \\ only one device address. 110-T-11ITIM M- M-1 Model Description 4090-9002 1 Relay lAM Optional Adapter and Trim Plates Model Description 4090-9813 Adapter plate to fit 11/16 (119 mm) square I electrical box 4090-9801 For semi-flush I Trim Plate, galvanized mounted box I steel, with LED viewing For surface I window; includes 4090-9802 mounted box mounting screws S * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simples product supplier for the latest status. Listings and approvals under Simples Time Recorder Co. are the property of Tyco Fire Protection Products. urn iii mire 4090-9002 Q S4090-0002-10 11/2014 rRelay lAM Mounting Information Address setting under resealable label 4" (102 mm) square box, 2-1/8' (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © © © Light pipe for LED viewing 4-9/16' /' 4-5/16" (116 mm) OE1Po [scEcT! 'O (109 mm) EhJF Srsiss S vs IF © © © © 4 4-9/16" (116 mm) IPI 4 -4-5/16(109mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SI PLLX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. S.Simplex Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4090-0002-10 11/2014 www.simp!ex-tire.com 02014 Tyco Fire Protection Products. All rights reserved All spec/lcaIions and other information shown were current as of document revision date and are subject to change without notice. [11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexloO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Models* 4090-9001, -9001TSP, -9001TTP, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002TSP, and -900211P lAM Relay Module; 4090-9106, -910615P, and-910611P Class "A" ZAM Initiating Module; 4090-9101, -9101TSP, and -9101TTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: "Recert. 03-29-2006 jw This listing is based upon technical data submitted by the the test results and/or other data but does not make an independent applicant. CSFM Fire Engineering staff has reviewed verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct . operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division J1 S £LSimplEx Multi-Application Peripherals UL, ULC, CSFM Listed; IDNet Communicating Devices FM Approved* Model 4090-9010, 8 A Relay lAM S S Ii1 (*1 Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For use with following Simplex® control panels: Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 11/16" t/ square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow LED to be viewed after installation UL listed to Standard 864 beiiption 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. ir W.-VI UNA ii Model Description 4090-9010 8 A Relay lAM Optional Trim Plates and Adapter Model Description 4090-9801 I I For semi-flush I Trim plate, galvanized mounted box I steel, with LED viewing I For surface I window; includes 4090-9802 mounted box mounting screws 4090-9813 Adapter plate to fit 4 (119 mm) square electrical box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4090-9010 8 A IDNet Relay lAM Package (shown approximately 1/2 size) cificatk Communications IDNet communications, 1 address per device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* (not rated for incandescent switching) Type Separate contacts; 1, NO and 1, NC Maximum Voltage 250 VAC or 30 VDC Ratings Current Ratings 8A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4%°Hx4'Wx1 3h"D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32° to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range I Up to 93% RH at 100° F (38° C) S4090-0015-1 1112014 8 A Relay lAM Mounting Information S 4" (102 mm) square box, 2-1/8' (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © © © Ad supplied label tof L IAVflSSlT: coverd o - n-site if controlling AVflSSlT:I 4-9/16" 120 or 240 VAC L) 4-5/16" (116 mm) (1109 Trim) Light pipe for LED viewing © © © © 1.111 -4-9/16" (116 mm) oo .1 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited ®S i in p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4090-0015-1 11/2014 0 2014 Tyco Fire Protection Products. All rights reset-red. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexlOO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4090-9118 relay lAM (individually addressable module) module, 4090-9119 relay lAM module with unsupervised feedback, 4090-9008 dual relay lAM, *4090..9010 eight amp relay lAM and 4090-9120 six-point I/O module. (lAM). Refer to listees data sheet for detailed product description and operational considerations. RATING: 30VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. S *Rev. 04-24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct S operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division iSim plEx UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* IT1(!ti4-1 Dual port, bi-directional communications short circuit isolator: Compatible with Simplex® 4007ES, 4008, 4010ES, 4100ES, or 4100U Series fire alarm control panel IDNet Signaling Line Circuits (SLCs) providing: IDNet, 1DNet+, IDNet 1+, IDNet 2, or IDNet 2+2 output loops (see additional information on pages 2 and 3) Either port can serve as an input or output, ports are automatically separated when a communications short circuit occurs Isolation can also be activated from the control panel for system diagnostics Mounts in standard 4" (102 mm) square electrical box, optional adapter plate is available to mount in a 4 '/ (119 mm) square electrical box LED flashes to indicate communications; optional covers are available to view LED after installation TrueAlarm sensor base IDNet Isolators are also available, refer to data sheet S4098-0025 for details UL listed to Standard 864 Earth fault isolation reduces time to fix wiring problems: Built-in control panel diagnostics assist in locating earth fault conditions - the most common installatio wiring problem For Class B or Class A wiring: Communications are monitored from either port Class A wired SLCs can optimize operation by maintaining communications with devices outside of the isolated wiring section strintie 4090-9116 Addressable IDNet Communications Isolators provide IDNet communications isolation to improve installation convenience and increase system integrity. Isolation is automatically activated when an output short circuit is detected and isolation can also be selected manually from the control panel to assist with troubleshooting wiring problems. Operation. Isolators power-up in isolation mode and are directed to connect by the control panel. If the output wiring is acceptable, the isolator will connect to the rest of the circuit. If the output wiring is shorted, the isolator remains isolated. Addressable Peripherals 4090-9116 Addressable IDNet Communications Isolator 4090-9116 Addressable IDNet Isolator (shown approximately 1/2 size) I'i*HiT(Iii7YIl1i?1JJj Status Tracking. The isolator reports back to the panel when it is in isolation mode and the extent of shorted wiring is reported back to the panel by identifying device addresses that are not communicating. [Isolators are assigned sequentially to low number addresses to expedite SLC power-up.] Earth Faults. During installation, earth faults frequently occur. Finding these faults normally requires extensive wiring disconnection. With the 4090-9116 Addressable IDNet Isolator, earth faults on the IDNet communications lines can be quickly located to assist in their repair and to restore the system wiring to normal. EMNOTJ Model Description 4090-9116 Addressable IDNet Communications Isolator 40909813 I Adapter plate to fit 4 1 /16 (119 mm) square electrical box 4090-9801 For semi-flush I Optional trim plate with mounted box I LED viewing window, For surface includes mounting screws; 4090-9802 mounted box galvanized steel * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:252 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplierfor the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products, S4090-0005-8 10/2014 Class B riser Simplex 4100ES Series Fire Control Panel (shown for reference) S Multi-Floor Isolator Example I Short Circuit Isolation. The one-line diagram on this page shows a multiple floor example with Class B IDNet communications for each floor starting at an isolator. (A sensor in the 4098-9793 Isolator Base is shown for reference as an alternate isolating device.) If floor wiring beyond the isolator should experience a short circuit, each floor is automatically separated from the next, preventing the short circuit from disabling the entire IDNet communications wiring. Earth Fault Isolation. In the event of an earth fault, each floor can be individually isolated using built-in control panel diagnostics. With individual floor control, the earth fault can be isolated to the floor level to narrow the search area. By adding more isolators, the section required to be isolated can be reduced, allowing more devices to remain active. S Fourth floor - L Third floor Isolator base Second floor L S First floor Compatible IDNet communications, 2 wire (see wiring notes) p - 4090-9116 Addressable IDNet Isolator IDNet Compatible TrueAlarm sensor and base Other IDNet device type (addressable station, ZAM, lAM, etc.) Wiring Notes: Operation of the 4090-9116 Addressable IDNet Isolator requires connection to compatible 4007ES, 4008, 4010ES, 4100ES, or 4100U IDNet communications channel. NOTE: The 4100-3103 Panel Mounted Quad Isolator is compatible only with MAPNET II Remote Isolators. Maximum line resistance between the panel and an isolator, and between two isolators, is 10 0 or 780 ft (238 m) with 18 AWG wire. This is a one-line drawing showing only IDNet communications wiring. Some IDNet devices require additional wiring for power. Refer to specific devices for details. S4090-0005-8 10/2014 P_~=j ujwu il Third floor C Second floor =- Multi-Floor IsolatOr Example 2 S Class A Wiring. The illustration below is a modification of Example 1. Each floor is wired as a Class A connection, and a sensor mounted in a 4098-9793 Isolator Base has been added for reference. This, illustrates that with additional isolators (either the 4090-9116 or the Isolator Base), there is a reduction in the number of isolated devices in the event of a short circuit. Isolator bases (see note 6) Diagnostic Assistance. Communications from an IDNet 2, IDNet 2+2, or 1DNet+ output provide individual short circuit isolation and allow individual output control to provide assistance in locating wiring faults. Note: When wiring Class A IDNet communications provided by IDNet or IDNet 1+ outputs, locate isolators as the first and last devices in the loop, close to the panel, to provide loop short circuit isolation operation (as shown below). ------------------ Alternate Wiring Example Class A riser with Isolators using Class B taps Fourth floor First device Last device First floor : 4090-9116 Addressable IDNet Isolator IDNet Compatible TrueAlarm sensor and base Other IDNet device (addressable station, ZAM, lAM, etc.) Wiring Notes: Operation of the 4090-9116 Addressable IDNet Isolator requires connection to a compatible 4007E5, 4008, 4010ES, 4100ES, or 4100U IDNet communications channel. NOTE: The 4100-3103 Panel Mounted Quad Isolator is compatible only with MAPNET II Remote Isolators. For Class A communications from IDNet or IDNet 1+ outputs, locate IDNet Isolators as the first and last device in the loop, close to the panel, to optimize loop short circuit protection. This is not required with IDNet 2, IDNet 2+2, or lDNet+ outputs. S 4. Maximum line resistance between the panel and an isolator, and between two isolators, is 10 0 or 780 ft (238 m) with 18 AWG wire. This is a one-line drawing showing only IDNet communications wiring. Some IDNet devices require additional wiring for power. Refer to specific devices for details. Class A IDNet Circuit IhiI Simplex 4100ES Series Fire Alarm Control (shown for reference) Compatible IDNet communications, 2 wire (see Wiring Note 3) S4090-0005-8 10/2014 Mounting Information Address setting under resealable label ,- C~b C) 0 0 0 d 0 Zj 4" (102 mm) square box, 2-1/8' (54 mm) minimum depth, RACO 232 or equal (supplied by others) 'Status LED X 4090-9116 Addressable IDNet Isolator Label front view Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) 9 Mounting Reference, Double Gang Blank Cover Plate 4-9/16" (116 mm) © © © © Light pipe for LED viewing 4-5/16" (109 mm) © © © © —4-9/16(116 mm) i( 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED 4 S4090-0005-8 10/2014 S Electrical Communications IDNet communications, 1 address per device Compatibility ompa 4007ES, 4008, 4010ES, 4100ES, and 4100U providing: IDNet, IDNet+, IDNet 1+, IDNet2, or IDNet 2+2 communications output; (not compatible with 4100-3103 Panel Mounted Quad Isolator) Power Consumes one unit load, power is supplied from IDNet SLC Wire Connections Screw terminals for input and output wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm 2 ) Wiring Distances IDNet Wiring Reference Mechanical Up to 2500 ft ( 762 m) from fire alarm control panel Up to 10,000 ft ( 3048 m) total wiring distance (including 1-Taps) Maximum line resistance between panel and isolator, or between isolators is 10 ohms; [18 AWG (0.82 mm2 ) = 780 ft (238 m)] Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 41/8' H x 41/8' W 1 %" D (105 mm x 105 mm x 35 mm) Package Black thermoplastic housing on metal mounting plate Temperature 32° to 120° F (0° to 49° C) indoor operation only Humidity Range 10 to 90% RH at 90° F (32° C) Installation Instructions 574-872 ~-1 S S4090-0005-8 10/2014 C TYCO, SJJv1FLEJ( and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. 0 9; ,, SimplFx Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4090-0005-8 10/2014 iwvw.simplex-fire.com 02014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0252 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Models 4090-9116, -9116TSP, -9116TTP IDNet Isolator; 4090-9117 power Isolator; and 4090-9121 security lAM. Refer to listee's data sheet for additional detailed product description and operational considerations RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. - MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. *The models identified on this listing have been tested and recertified to UL-864, 9th Edition Standards. Refer to listee's Installation Instruction Manual for details. S *Rev. 08-28-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct S operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S S ø5implEx UL, ULC, CSFM Listed; FM Approved, MEA (NYC) Acceptance* Install the model 4098-9714 TrueAlarm analog photoelectric sensor directly inside air ducts**: Accommodates duct airflow from 0 to 4000 ft/mm (0 to 1220 mlmin), providing HVAC duct smoke sensing where sampling tube designs are not appropriate For applications with controlled dust and humidity Standard models are for rectangular ducts from 6" (152 mm) square to 36" (914 mm) square Optional adapters allow use with round ducts of 6", 8" (203 mm), 10" (254 mm) or 12" (305 mm) in diameter TrueAlarm analog communications can be either JDNetorMAPNETJ1 format Model 4098-9714 sensor is required and ordered separately Red alarm LED indicator in housing: Visible through transparent housing cover Pulsing indicates power-on, steady on indicates alarm or trouble as indicated at the fire alarm control panel Model 4098-9750 provides two-wire operation (no relay output) Model 4098-9751 provides a local relay: Relay operation is programmable from fire alarm control panel and is rated: 1 A @ 28 VDC, power limited; or 1/2 A @ 120 VAC, non-power limited 24 VDC power is supplied by fire alarm system (4-wire operation) Options: Adapters for 6", 8", 10" or 12" round ducts Remote Test Station (2098-9806) Remote LED Alarm Indicator (2098-9808) UL listed to Standard 268A ** Please note that smoke detection in air ducts is intended to notify of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 1344.1 of the California Health and Safety Code. See CSFM Listing 3240-0026:220 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. ULC listed models are designated with a suffix such as 4098-9750C. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. TrueAlarm Analog Sensing In-Duct Mounting of the 4098-9714 TrueAlarm Photoelectric Smoke Sensor In-Duct Housing with 4098-9714 Sensor (mounted in 8' square duct for reference) 1pninrinfir HVAC air ducts in buildings supply fresh air and exhaust stale air. Depending on the overall fire detection requirements, smoke detection may be required in the air ducts. For applications where sampling tube type duct detection is not appropriate due to low air velocity or small duct size, Simplex® model 4098-9750 and 4098-9751 housings can be used to install the Simplex model 4098-9714 TrueAlarm analog sensor directly in the duct. (Refer to data sheet S4098-0030 for smoke sensor housings with sampling tubes.) Application. These housings mount a spot-type smoke sensor directly into the duct airflow. Proper application requires controlled dust and humidity. Please note that in the event of loss of duct airflow, the 4098-9714 sensor will sense smoke IF the smoke reaches the sensor. However, with no duct airflow, smoke may not reach the sensor depending on the location of the smoke source relative to the sensor. TrueAlarm Operation. Placing a 4098-9714 sensor in an air duct provides the high reliability performance of TrueAlarm analog sensing featuring: programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation. These housings digitally communicate their analog sensor information to the fire alarm control panel using either IDNet or MAPNET II two-wire communications. Relay Model. Model 4098-9751 provides a relay that can be programmed to track the local sensor's operation or can be independently controlled by the fire alarm control panel to perform fire response actions such as fan shutdown and damper control. S4098-0021-7 10/2011 Model Description Compatibility 4098-9750 In-Duct Sensor Housing without relay Simplex 4100ES, 4100U, 401OES, 4010, 4020, 4100, 4120, and 2120 CDT configured for MAPNET II TrueAlarm communications with beige mounting box, Simplex 4100ES, 4100U, 4O1OES, 4010, 4020, 4100, and 4120 4098-9751 (requires 4098-9714 sensor) with relay (not compatible with 2120 CDT) 4098-9714 1 Photoelectric Sensor Head Ordered separately, required for 4098-9750 or 4098-9751 In-Duct Sensor Options, ordered separately as required, compatible with both 4098-9750 and 4098-9751 4098-9819 Adapter for 6" (152 mm) round duct, beige 4098-9824 Adapter for 8" (203 mm) round duct, beige 4098-9852 Adapter for 10" (254 mm) round duct, beige 4098-9853 Adapter for 12" (305 mm) round duct, beige 2098-9806 Remote Test Station mounted on single gang stainless steel plate 2098-9808 1 Remote LED Alarm Indicator mounted on single gang stainless steel plate S Rectangular Duct Mounting Reference In-Duct sensor access requires wiring with flexible conduit (supplied separately) External mounting box 7-1/4" H x 7-1/8" W 2" D (184 mm x 181 mm x 51 mm) Transparent housing cover allows viewing of status LEDs Sensor base / (supplied) 8 Inch square duct (shown for reference) UJ ' Sensor head II 4098-9714 II (ordered H separately) - S Gasket Gasket (supplied)) Gasket (supplied) LI 5-1/4" (133 mm) Mounting Notes for both Square and Round Duct Applications: Reference drawings are shown mounted to the side of the duct. Where appropriate, top mounting may be acceptable. Contact your local Simplex product supplier for assistance. The 4098-9750 and 4098-9751 In-Duct assemblies include sensor base assembly, mounting box and cover, and mounting gaskets. The 4098-9714 sensor head is ordered separately. Templates are supplied for duct cutout size and location. Refer to installation instructions 574-711 for additional information. Adapters for 6", 8", 10", or 12" round duct applications are ordered separately. 2 S4098-0021-7 10/2011 S Round Duct Mounting Reference S S In-Duct sensor access requires ( wiring with flexible conduit 4098-9824 (supplied) (supplied separately) 8 Adapter / I II $'AQ Gasket II (supplied) External mounting box / 8lhi 7-1/4Hx7-1/8"Wx2"D. II Inch air (184 mm x 181 mm x 51 mm) (shown for reference) Cd 0 Sensor head I 4098-9714 Transparent housing cover .__v1 (ordered separately) allows viewing of status LEDs I I Sensor base (supplied) (19 mm) L (111 mm) 3/4" 4-3/8 ntp Indicator Ontic 2098-9806, Remote Test Station (below), provides a 2098-9808, Remote LED Alarm Indicator (below), remote red LED status indicator and a remote test key provides a remote Red LED status indicator mounted on a switch mounted on a single gang stainless steel plate. single gang stainless steel plate. Turning the test switch to "TEST" will initiate an alarm and allow the resulting system responses to be verified. 2098-9808 Remote LED Alarm Indicator 2098-9806 Remote Test Station Remote Indicator Mounting. Both the 2098-9806 and S 2098-9808 Remote status indicators mount in standard single gang boxes, 2" W x 3" H (51 mm x 76 mm) with a minimum depth of 2", supplied separately. 3 S4098-0021-7 10/2011 Location Reference Duct Sensor Location Considerations: Proper duct smoke detection location must ensure adequate airflow within the duct housing. The recommended air velocity range for these in-duct sensors is 35 to 600 ft/min (11 to 183 rn/mm). To avoid air turbulence, a location of six duct widths downstream from bends or inlets is desirable. Ensure accessibility for test and service. Proper Locations: downstream side of filters to detect fires in the filters; in return ducts, ahead of mixing areas; upstream of air humidifier and cooling coil. Other locations may be required for proper duct smoke detection depending on duct access, system design, and duct airflow testing. Contact your local Simplex product supplier for assistance. In-Duct Sensor Location Reference Exhaust Sensor Damper OK Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Additional Information. Refer to NFPA 90A, Standard for the Installation ofAir Conditioning and Ventilating Systems; NFPA 72, the National Fire Alarm and Signaling Code; and the NEMA Guide for Proper Use of Smoke Detectors in Duct Applications, and Installation Instructions 574-711. Exhaust Return I Bend or other Air I I obstruction Do not locate sensor here Return air damper 6Duct widths - Top mount, if desirable appropriate n Fresh air Specifications Do not locate bank sensor here Supply Air Return air Sensor inlet ' 6 Duct OK L widths desirable Recommended Air Velocity Range 35-600 ft/mm (11 to 183 rn/mm) NOTE: See UL Listed Air Velocity Range 0-4000 ft/mm (0-1220 m/min) with a mm. sensor sensitivity of 3.0% per ft 0-2000 ft/mm (0-610 rn/mm) with a mm. sensor sensitivity of 3.7% per ft application discussion on page 1. Data Communications lDNet or MAPNET II format, auto-selected, 1 address per housing Remote LED Current 0.6 mA, no impact to alarm current UL Listed Temperature Range 32° to 100° F (0° to 38° C) Operating Temperature Range 15° to 122° F (-9° to 50° C) Humidity Range 10% to 90% RH from 32° F to 122° F (0° C to +50° C) Wiring Connections Terminal blocks for wire size 18 to 14 AWG (0.82 mm2 to 2.08 mm2 ) Dimensions Refer to round and square duct mounting diagrams Relay Power (4098-9751 only) Voltage 18 to 32 VDC Standby Current 240 1iA @ 24 VDC Alarm Current 30 mA @ 24 VDC Power Limited Contact Rating Single form "C", 1 A @ 28 VDC (for suppressed loads) Non-Power Limited Contact Rating Single form "C", 1/2 A @ 120 VAC, resistive (for suppressed loads) TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). irn p1 EX Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S4098-0021-7 10/2011 www.simplexgrinnell.com 02011 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. S Duct Sensor Housing, Front and Bottom View 0 0 0 0 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station r.rrrini Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueAlarm sensors and IDNet and MAPNET II communications are protected by one or more of the following U.S Patents: 5,155,468; 5,173683; 5,543,777; 5,400,014; 5,543,777; 5,710,541; 0383,407; 0388,352; 0392,573; 4,796,025. 5 Simplex TrueAlarm® Analog Sensing UL, ULC, CSFM Listed; FM Approved,, Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control I4Ii(4-U Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed lrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNetTM or MAPNET 116, 2-wire communicationst Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by IDNetIMAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control . At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interface board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) . * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4098-0030-5 3/2007 k i iiiiii.i!isxtYtIIThThJli71J i1rrt.11iT1Ff(.1i!lirJI Control Panel Selection. Peak activity per sensor is Typically duct sensor applications require less sensitive stored to assist in evaluating specific locations. The alarm settings (such as 2.5% per foot obscuration) due to the set point for each sensor is determined at the control ducts being a relative dirty environment. However, the panel, selectable as the individual application requires. standard seven levels of TrueAlarm sensor sensitivity are Sensor Status LED. Each sensor housing's red status available for each individual sensor, ranging from 0.2% to LED (located on the electrical interface board) pulses to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's • Individual smoke sensitivity selection status LED will be turned on steadily. During a system • Sensitivity monitoring that satisfies NFPA 72 alarm, the control panel will control the LEDs such that sensitivity testing requirements an LED indicating a trouble will return to pulsing to help • Peak value logging allows accurate analysis for identify any alarmed sensors. (Remote Status/Alarm sensitivity selection LEDs track the operation of the sensor housing LED.) Automatic, once per minute individual sensor IT1fltIflir1flT] calibration check verifies sensor integrity TrueAlarm photoelectric sensors use a stable, pulsed • Automatic environmental compensation infrared LED light source and a silicon photodiode • Smoke sensitivity is displayed in percent per foot receiver to provide consistent and accurate low power • Ability to display and print detailed sensor smoke sensing. information in plain English language Relays of model 4098-9756 are under panel control for ON, OFF, or override Duct Smoke Sensor Housing with Photoelectric Sensor* Model Description Compatibility Basic Duct Sensor Housing: operating power is supplied by Simplex fire alarm control panel models 4010, 4098-9755 either IDNet or MAPNET II communications (no relay output) 4020, 4100, 4100U, and 4120. Also 2120 CDT if configured for MAPNET II, TrueAlarm operation S Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not compatible with 2120 CDT: 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 end-of-line resistor harness: includes one 4098-9843 relay Relay output is for up to 15 total 4098-9843 Relays (additional relays are ordered separately) \\ Remote LED Indicator and Test Station, Select One if Required Model Description Compatibility Mounting 2098-9808 Red LED status indicator 4098-9755 Use single gang box, 2098-9806 Test Station with keyswitch and red LED status indicator 4098-9756 3" Hx2"Wx2"D (76 mm x 51 mm x 51 mm) (turning switch to 'TEST" initiates alarm for system testing) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay: single Form C (7 A @ 120 VAC): refer to pages 3 and 4 4098-9756 only: Locate relays within 3 ft 4098-9843 for additional relay information: one included with 4098-9756: (1 m) of device being wiring is 18 AWG (0.82 mm2 ) color coded wire leads connect up to 15 controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness: 10 kQ, 1/2W: (ref. 733-894): 4098-9756 At last relay location required to supervise remote relay coil connection * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Overall Duct Width (305 mm) Tube Required 2098-9796 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 2098-9804 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 2098-9797 2" (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2" (51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 2098-9799 1 2" (51 mm) longer than duct width S4098-0030-5 3/2007 S I NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. 11-3/8" (289 mm) [Exhaust tube access hole) C 4098-9714 Smoke s r n special interface base (supplied_ _ ___ IDOL- (171m:) 0,71130 00 access hole 1 \Sampling tube r N i - - •'•i. CC IStfirnry hffl (hiiitiniY 01 ICaptive fasteninq screws (4) lMaonetic test areal (jasKetea sensor area] 3-3/8" 41111w4 g-1 if ps m: ~== mo TA S Metal plate with dual holes for 3/4"(l9mm) conduit, plug supplied for unused hole Yellow LED, relay control trouble indicator (4098-9756 only) All Red sensor status LED of duct Mount as shown (preferred) or with electronics area located to the LEFT or UP ONLY (21 mm) [71 Test ports (2) provided for measuring airflow and for aerosol injection Sampling tube, ordered separately per duct width Exhaust tube (supplied) Duct wall S End View with Duct and Tubes Duct housing Round duct outline I (minimum di J Sampling tube, keyed for proper hole alignment with holes facing into airflow (template is provided for proper tube installation) 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 (38 mm) 1-3/16" (30 mm) 3 S4098-0030-5 3/2007 I off 11JI!!.] iiI1 Mel (it,t*i Exhaust Sensor Damper OK Exhaust ,,.Return Air Do not locate sensor here Return air damper Fresh air Supply Air Filter Sensor Do not locate bank OK sen ::50r here Bend or other obstruction Return ai 6 Duct ED inlet 6 Duct 9 m t( widths minimum widths minimum Preferred Duct Sensor Locations: A minimum of six duct widths downstream from bends or inlets to avoid air turbulence. On the downstream side of filters to detect fires in the filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A, Standardfor the Installation ofAir Conditioning and Ventilating Systems. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Outdoor Applications Note: For outdoor applications, refer to data sheet S4098-0032 for information on weatherproof enclosure 4098-9845. S Specifications General Mechanical and Environmental Air Velocity Range (linear ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 103.31 mm2 ) Housing Color Remote Status/Alarm LED and Test Station with Remote Alarm LED Current Black base with clear cover Remote Status/Alarm LED 1.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Addressable Operation I IDNet or MAPNET II communications, auto-select, one address per housing; Data Communications provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply 18-32 VDC (24 VDC nominal) Standby Current 13 mA @ 24 VDC Alarm Current (one relay activated) 15 mA @ 24 VDC; add 15 mA for each additional remote 4098-9843 relay For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft Supervised Remote Relay Control Output (152 m) maximum; requires 4081-9008 (ref. 733-894)10 kQ, 1/2 Wend-of-line resistor 4098-9843 Relay Output Ratings Single Form C use with Model 4098-9756 Only Coil Current 115 mA@24 VDC, up to 15 maximum per relay control output Relay Contacts 7Aat0.35PF@ 250 pA@5VDC 2B VDC & 120 VAC Location Distance I 500 ft (152 m) maximum to relay coils; relays must be within 3 ft (1 m) of device being controlled per NFPA 72 Tyco, Simplex, the Simplex logo, TrueAlarm, IDNet, and IvL4PNET1I are trademarks of Tyco International Services AG or its affiliates in the US. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA) ®SirnpIex Tyco Safety Products Westminster° Westminster, MA 0 144 1-000 1 USA S4098-0030-5 3/2007 www.tycosafetyproducts-usa-wm.com 0 2007 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as ofdocu,nent revision date and are subject to change without notice. fl S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:0220 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Model 4098-9750, -9751, -9752, -9753 and -9681 duct detector units. Models 4098-9752, -9753 and -9681 consist of a thermal plastic enclosure, electrical component, a listed smoke detector 4098-9714 (CSFM Listing No. 7272-0026:218) or 4098-9601 (CSFM Listing No. 7272-0026-219), a detector base and a sampling and exhaust tube. Model 4098-9601 detector head is intended for use only with Model 4098-9681 duct detector unit. Models 4098-9750 and -9751 consist of a steel box, an extension nipple, electrical components (mounted inside the box), a listed smoke detector Model 4098-9714 (CSFM Listing No. 7272-0026:218) and a detector base. Refer to listee's data sheet for additional detailed system description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, air velocity rating and UL label. APPROVAL: Listed as a duct detector unit for use with separately listed compatible fire alarm control units. Intended for use with Models 4098-9791, -9792, -9682, -9683 or -9788 detector base. 5 For indoor use only. *Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE EI LISTING No. 3240-0026:0241 Page 1 of 1 CATEGORY: 3240 - DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: SimplexlOO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Models 4098-9755, *4098..9755Tsp *4098..9755up 4098-9756, *4098..9756Tsp *4098..9756up 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/min INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: S *Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0150 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyettetycoint.com DESIGN: Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Model 409-9835 remote power/alarm indicator with test switch; Model 2098-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with projected beam detector systems. NOTE: *Rev. 05-12-2003 TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division G.SimpWX System Accessories UL, CSFM Listed; Fire Alarm Control Relays, Track Mount and MEA (NYC) Acceptance* Encapsulated; Model 4098-9843 and 2088 Series UL listed under Standard 864 as Control Unit Accessory (UOXX) Track mount package availability: Single relay module or four relay module, with or without cover, with SPDT or DPDT contacts LED indicates relay module status Cover provide status LED viewing ports Multiple coil voltage inputs, diode polarized for DC Modules are track mounted with snap-apart feature design allowing the four relay module to be separated Single encapsulated SPDT relay package with color coded 18 AWG wire leads, available in two versions: 2088-9021 (PAM- 1)Provides diode polarized multiple input voltage ability and LED indication 4098-9843 (PAM-SD) Provides a diode polarized 24 VDC coil with in/out wiring I'i*i11It1 These multi-purpose control relays offer SPDT or DPDT, 10 A (or 7 A) contacts in a variety of mechanical packages. Models are available for coil operation by one of four input voltages allowing a single relay to be energized from a voltage source of 18-35 VDC or VAC, 120 VAC, or 230 VAC (not available with 4098-9843). Voltage selection is made by wiring to the appropriate input terminals or wire leads. Each relay model (except model 4098-9843) contains a red LED which indicates that the relay is energized. Mounting options are varied for application flexibility. Track mounted relays may be "snapped apart" from a standard four-module assembly and used independently if desired. PT1191"M "I Track Mount Relays, see page 2 for dimensions Coil Voltage 18-35 VACNDC, 120, or 230 VAC Coil Current SPDT models = 18 mA DPDT models =40 mA Terminal Blocks Up to 14 AWG (2.08 mm2 ) Contact Ratings 10A@ 120 VAC N.O. rated 1/6 HP, N.C. rated 1/8 HP 7A @ 28 VDC and @ 230 VAC Temperature Ratings UL Listed Range 32° F to 120° F (0° C to 49° C) Humidity 85% RH Non-condensing NO -a ,.c ON: WIfl, 10 14+tti ONO 14flhl• 0 S 2088-9020, MR204/C, Four DPDT Relay Package with Enclosure (shown with cover removed) Encapsulated Relay Package (typical of 2088-9021, PAW and 4098-9843, PAM-SD) Specifications Continued Encapsulated Relays, see page 2 for dimensions Connections 18 AWG (0.82 mm2 ) color-coded I wire leads Relay 2088-9021 Contact Ratings 10 A @ 120 VAC, resistive Voltage 18-35 VACNDC, 120, or 240 VAC Coil 15 mA @ 24 VACNDC, Ratings Current I &@120 0r230VAC Relay 4098-9843 Coil Ratings 118-32 VDC input, polarized, 15 mA I @ 24 VDC 7 A at 0.35 p.f @ 28 VDC & Contact Ratings 1 120 VAC 250 pA @ 5 VDC Temperature Ratings UL Listed Range 32° F to 120° F (0° C to 49° C) Humidity 100% RH, condensing * Listings are under Apollo America Inc. per model numbers shown on page 2. See CSFM Listing 7300-1004:0101 for allowable values and/or conditions concerning material presented in this document. S2088-0010-10 11/2014 Module Reference Model Relay Packaging Dimensions Positions Number Number Type 2088-9007 MR-11T SPDT 3-1/4" H x 2-1/8" W 1-1/2" D Track mount, without cover (83 mm x 54 mm x 38 mm) 2088-9009 MR-201[T DPDT One 2088-9008 MR101/C SPDT 5-1/8" H x 3-1/8" W x 2-1/2" D Track mount with cover (131 mm x 79 mm x 64 mm) 2088-9010 MR-201/C DPDT 2088-9017 MR104/T SPDT 3-1/4" Hx8-1/2"Wx 1-1/2" D Track mount, without cover (83 mm x 216 mm x 38 mm) 2088-9019 MR-204/T DPDT 2088-9018 MR-104/C SPOT 5-1/8" H x 9-1/2" W 2-1/2" D Track mount with cover (131 mm x 241 mm x 64 mm) 2088-9020 MR-204/C DPDT Encapsulated, multi-voltage coil, color coded 18 AWG (0.82 mm2 ) wire 1-1/2' H 7/8" D 2088-9021 PAM-1 (38 mm x 25.4 mm x 22 mm) ____________ ____________ leads, with coil status LED NA SPOT Encapsulated, 24 VDC coil, color coded 18 AWG (0.82 mm2 ) wire leads (no 1-1/2" H x 1-3/16" W 13/16" D 4098-9843 PAM-SD (38 mm x 30 mm x 21 mm) LED) S N NC C NO J@ @ 0 18/24 115 230 Relay energized LED (18-35) VDC Coil voltage (note polarity (1835) VAC for DC) 120 VAC 230 VAC Terminal strip connections DPDT models Relay Selection Chart Track Mount Relay Wiring Reference SPDT contacts rated DPDT contacts rated 10 A @ 120 VAC, resistive 10 A @ 120 VAC, resistive (18-35) VDC Coil voltage (note polarity (18-35) VAC for DC) 120 VAC 230 VAC Terminal strip connections SPOT models TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. S BSi rn plEx Tyco Fire Protection Products • Westminster, MA •01441-0001 USA S2088-0010-10 11/2014 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:0101 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Apollo America Inc.25 Corporate Dr., Auburn Hills, MI 48326 Contact: John Schertel (248) 332-3900 Fax (248) 332-8807 Email: John.Schertel@apollo-fire.com DESIGN: Models MR-101/C, *MRioi/c/R *MRioissE/C *MRioiSSE/c/R MR-104/C, *MRI04/C/R, *MR104SSE/C *MR104..SSE/CIR MR-201/C, MR.201/C/*R, *MR201SSE/C *MR201SSE/C/R, MR-204/C, MR-204/C/-R, *MR204SSEIC *MR.204SSE/C/R PAM-1, PAM-2, PAM-3, PAM-4, PAM-SD, RIC-1, RlC-2, RIC-3, RlC4, MRRC301/*C, *MRR1C..301/C/R MRRlC.305*/C, * MR-RIC-305/C/R, MRRlC401*/C, *MRRlCAoi/C/R MRRlC405*/C and *MR..RIC405/c/R relay modules. *Models MR-ITM/C and MR-ITM/CIR relay modules (with test mode). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. 5 NOTE: 1. Formerly Air Products and Controls, Inc. *Rev. 04-03-14 gt rs*, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S operational Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S 55impIEx TrueAlert Addressable Notification Appliances UL, ULC Listed* _____ Wall and Ceiling Mount Addressable Speaker and Speaker Visible Notification Appliances S S I11!I i4-1 Individually addressed and controlled Speaker (SIO) and Speaker Visible (SN) notification appliances Advanced addressable notification controlled by IDNAC SLCs provides regulated 29 VDC for low current operation even under battery backup. Wiring supervision is electronically monitored and allows audio wiring to be T-tapped for class B wiring, reducing wiring costs and wiring distances. Speaker selectivity is controlled by the panel. Only those speakers that are needed are connected to the audio NAC. Separate appliance and cover selection greatly simplifies the ordering and installation process. Strobe intensity can be programmed from the control panel or the device for S/V models. Self-Test Mode allows on-board sensors to detect the strobe and speaker output and then report their status to the control panel. Wiring terminals separate from the Audio terminals. TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting. Magnet test diagnostics to assist checkout and testing of appliances and wiring. Compatibility with ADA requirements. LED indicator and magnet test feature Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address and pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount models Covers are available in red or white with various lettering options Covers can be easily removed without disturbing the connected housing and avoiding trouble conditions In/out wiring terminals for 18 AWG to 12 AWG Mounts to 4" square 2 Y8" gang US electrical boxes * Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Ceiling and Wall Mount Addressable Speaker Only and Speaker Visible Strobes 14!It*I(Wi7iTi1J Speaker design features High quality voice and tone reproduction with taps for ¼, V2, 1, or 2 W, at 25 or 70.7 VRMS Speakers have capacitor input for connection to DC supervised NACs and are wired separately from strobes Listed to tilL 1480 and ULC S541* Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas High and low frequency response models available, 200-10000 Hz and 400-4000 Hz respectively. I'i*iiIllt1 Wall and-ceiling mount addressable speaker and speaker visible appliances provide convenient installation to standard electrical boxes. The speaker is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel IDNAC Signaling Line Circuit (SLC). Audio is provided by a panel that supports audio output or from a separate audio source. Appliances use a multi-tapped speaker for audio/tone notification. Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A 117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S49SWC-0001-1 11/2015 I I'] 0 U911IsI'ix tYT10 TrueAlert Addressable speaker and speaker visible appliances on IDNAC SLCs provide visible and audio notification using two separate two-wire circuits that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs A constant 29 VDC source voltage is maintained, even during battery standby. This allows appliances to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, use of smaller gauge wiring, or combinations of these benefits. Reducing Installation and Testing Time With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. ('I'['[[4['] •• \ Wall Mount SIO Appliances* (Refer to data sheet S49SOW-0001 for full product selection including covers and mounting plates) Model Dimensions I Description I Data Sheet Reference 49S0-APPLW(-BA) 5 %" H x 5" W x 1 '/2" D I S/O appliance only 349S0W 0001 \ 49HF-APPLW(-BA) (139 mm x 128 mm x 38 mm) High fidelity 5/0 appliance only \ Wall Mount SN Appliances* (Refer to data sheet S49SVW-0001 for full product selection including covers, mounting plates, and multi-color strobe lens) Model Series Dimensions Description Data Sheet Reference 49SV-APPLW(-BA) 7 /" H x 5" W x 1 3/4" D SN appliance only S49SVw-0001 49HFV-APPLW(-BA) (187 mm x 128 mm x 43 mm) High fidelity SN appliance only *Note: Wall mount models require separately ordered back plate. See related datasheet for details. V1 Mm Ceiling Mount SIO Appliances (Refer to data sheet S49SOC-0001 for full product selection and installation requirements) Model Dimensions Description Data Sheet Reference 49S0-APPLC(-BA) 7 'h' H x 7 Y8" W x 1 1/4 D S/O appliance only S49SoC-0001 49HF-APPLC(-BA) (180 mm x 180 mm x 32 mm) High fidelity SIO appliance only \. Ceiling Mount SN Appliances (Refer to data sheet S49SVC-0001 for full product selection and installation requirements) Model Series Dimensions Description Data Sheet Reference 495V-APPLC(-BA) SN appliance only 49HFV-APPLC(-BA) Hiqh fidelity SN aDDliance only 8 1/a H x 7 %"W x 3" D i-Iigrl canaeia IV appliance only Clear lens high fidelity high candela 49HFVH-APPLC(-BA) (206 mm x 180 mm x 76 mm) SN appliance only S49SVC-0001 Amber lens high fidelity high 49HFVH-APLCA-BA candela SN appliance only Blue lens high fidelity high candela 49HFVH-APLCB-BA SN aDDliance only Am Note: Select appliance, cover and mounting back plate (where required) separately. (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA are assembled in the USA TrueAlert Addressable Wiring Isolator Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. Refer to data sheet S4905-0001 for additional information. Test Features Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test The appliance LED pulses sequentially to conveniently indicate the appliance's address when a magnet is applied. Operational Appliance Testing In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT) The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. S 5495WC-0001-1 11/2015 S [1 IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Controller Output IDNAC SLC Output Appliance Voltage Reference Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4100ES Flex 35, 50, and 100 Amplifiers 4100ES Constant Supervision and Signal S4100-0034 Cards Specifications General Specifications (refer to individual model data sheets for further specifications, install and operation details) Typical Operating Voltage Range 23 - 30 VDC, Special Application Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (400 C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm' 103.31 mm'); two wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC and audio wiring. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible fire panel installation instructions for circuit current load limits. Speaker Specifications Input Voltage 1 25 or 70.7 Vrms 1/ 1/2, 1, and 2W Power Taps Frequency Response 400104000 Hz and 20010 10000 Hz, General Signaling = 12510 12 kHz resoectivelv. Strobe Specifications Typical Operating Voltage Range 23 - 30 VDC, Special Application Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate 1 Hz IDNAC SLC Wiring Specifications (refer to control panel installation instructions for more information) UTP, unshielded twisted pair recommended Maximum wire length allowed with "T-Taps" for Class B wiring per SLC = 10,000 It (3048 m) Maximum wire length to any appliance = 4000 ft (1219 m). This can be doubled to 8000ft (2438m) by using a 4009 IDNAC Repeater. Note: Speakers are for connection to compatible fire alarm audio circuits only. S49 Series Speaker Datasheet Reference Model Data Sheet Reference Wall Mount Speaker Only Appliance S49SOW-0001 Wall Mount Speaker Visible Appliance S49SVW-0001 Ceiling Mount Speaker Only Appliance S49SOC-0001 Ceiling Mount Speaker Visible Appliance S49SVC-0001 S49SWC-0001-1 11/2015 n S TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). 0 5 Tyco Fire Protection Products• Westminster, MA 01441-0001 USA S49SWC-0001-1 11/2015 www.simp!ex-fire .com 0 2015 Tyco Fire Protection Products. All rights reset-red All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026.-0384 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyelle@tycoint.com DESIGN: Models: 495V-APPLC,49HFV-APPLC,49SV-APPLC-BA,49HFV-APPLC-BA,49SVH-APPLC-BA, 49HFVH-APPLC-BA,49SVH-APPLC,49HFVH-APPLC,49SV-CWF,49HFV-CWF,495vH-Cvv F and 49HFVH-CWS True Alert ES, Addressable ceiling mounted Speaker/Strobes. Models: 49SV-APPLW,49HFV-APPLW,495V-APPLW-BA,49HFV-APPLW-BA,495V-WRF and 49HFV-WRF True Alert ES, Addressable wall mounted Speaker/Strobes. Models: 4950-APPLC, 49HF-APPLC, 49S0-APPLC-BA, 49HF-APPLC-BA,49S0-CW and 49HF-CW True Alert ES, ceiling mounted Speakers. Models: 4950-APPLW, 49HF-APPLW, 49S0-APPLW-BA, 49HF-APPLW-BA,49S0-WRF and S 49HF-WRF True Alert ES, wall mounted Speakers. Models: 49SVC-CK,495VC-CRALT,49SVC-CRFIRE,49SVC-CRS,495VC-CRBC,495VC-CWBC, 49SVC-CWFIRE,49SVC-CRFEU ,49SVC-CRBF,49SVC-CWALT,49SVC-CWBA,49SVC-CRB A,49SVC-CWS,49SVC-CWBF and 49SVC-CWFEU True Alert ES, Speaker/Strobe Ceiling Mount Dress Covers. Models: 49SVC-WRALT,49SVC-WRBA,49SVC-WRBC,49SVC-WRBF,49SVC-WRFEU,49SVC-WRFI RE,49SVC-WRS,49SVC-VWVALT,49SVC-WNBA,49SVC-WWBC,495VC-WWBF,49SvC-w WFEU,49SVC-W'VFlRE and 49SVC-WNS True Alert ES, Speaker/Strobe wall Mount Dress Covers. Models: 49S0C-CWFI RE,49S0C-CRFI RE,4950C-CRS,4950C-CWS,4950C-CK,49S0C-CR, 49S0C-CW,49S0C-CWALT and 4950C-CRALT True Alert ES, Speaker Ceiling Mount Dress Covers. 12-08-15 gt • This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S operational Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-0026:0384 Page 2 of 2 Models: 49SOCWRFEU,49SOC-WRBF,40SOCWRBC,49SOC-WRBA,49S0C-WtNS,49SOC-WNFI RE,49S0C-WRBLANK,49S0C-WRFI RE,49S0C-WRS,49S0C-VWVBA,49S0C-W'.NBC,49S OC-VWVBF,49S0C-\MNFEU,49S0C-\MNBLANK,49S0C-\MNALT and 49S0C-WRALT True Alert ES, Speaker Wall Mount Dress Cover. Models: 49MP-SVWR,49MP-SVWN,49MP-SOWR and 49MP-SOWiN True Alert ES,Back Plates. Models: 49SV-LENS-AMBER,49SV-LENS-BLUE,49SV-LENS-RED and 49SV-LENS-GREEN True Alert ES, Colored Lens Kit. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 23-30 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signalling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. S S 12-08-15 gt TF This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S j SPECIALISTS IN PRACTICAL PRECISION ENGINEERING"' S 0 TX SERIES TX-lOB Bridging Input Transformer Add transformer isolation to any line-level audio input Balanced input and output 10 kQ input bridges any audio line Frequency response: 20 Hz to 20 kHz (+1- 0.5 dB) THD: <0.05% (1 kHz) TX-LM2 Line Matching Transformer Matches a balanced 600 n phone or other audio line into a mic or line input Balanced input Dual outputs: Unbalanced line-level or balanced mic-level Frequency response: 20 Hz to 20 kHz (+1- 0.5 dB) THD: <0.05% (1 kHz) TX-1A Adjustable Line Transformer Provides transformer isolation between a balanced line and an unbalanced line input Level trimmer adjusts output 4 to 24 dB below input level Input may be 10 W bridging or 600 92 terminated Frequency response: 20 Hz to 20 kHz (+1- 0.5 dB) THD+N: <0.05% (1 kHz) TX-70A 100/70/25 Volt Input Interface Matches a 100, 70 0125 volt speaker line to any unbalanced line-level audio input Trimmer adjusts output level for various input voltages/power levels Frequency response: 20 Hz to 20 kHz (+1- 0.5 dB) THD+N: <0.05% (1 kHz) RDL • 659 6" St. • Prescott, AZ., USA 86301 • (928) 443-9391 • FAX (928) 443-9392 • www.rdlnet.com ,. k. a. ...n...a RDL SPECIALISTS IN PRACTICAL PRECISION ENGINEERINGTM .... U.. •f ... ......._ U Radio Design Labs TX` SERIES Installation/Operation C E EN55103-1 E11-E5; EN55103-2 Typical Performance reflects product at publication time exclusive of EMC data, if any, supplied with product. Specifications are subject to change without notice. TX-1013 TX-IA BRIDGING INPUT TRANSFORMER ADJUSTABLE LINE TRANSFORMER (\T INPUT FROM r V BALANCED LINE 1CONNECT IF REQUIRED OUTPUTTO ELECTRONIC-BALANCED EQUIPMENT INPUT TX-70A 25170/100 VOLT INTERFACE CONSTANT VOLTAGE LINE 0 ADJUST LEVEL SET TO 2EV, 7EV, OR FULLY COUNTER-CLOCKWISE FOR 100 V SYSTEM TRIM LEVEL AS NEEDED OUTPUTTO - UNBALANCED - EQUIPMENT INPUT CONNECT IF REQUIRED INPUT FROM BALANCED LINE 0 ADJUST LEVEL L OUTPUT TO ___UNBALANCED _______________ EQUIPMENT INPUT CONNECT IF REQUIRED INPUT FROM - rf 1EIIE BALANCED LINE Ø ADJUST LEVEL -, OUTPUTTO I I UNBALANCED V EQUIPMENT INPUT TX-LM2 LINE MATCHING TRANSFORMER i-CONNECT IF NEEDED TO-REDUCE HUM i-CONNECT IF NEEDED TO REDUCE HUM FROM LONG LINE FROM LONG LINE INPUT FROM INPUT FROM - BALANCED LINE BALANCED LINE (B00 OHM LINE) (600 OHM LINE) A OUTPUTTO LINE-LEVEL UNBALANCED : \L... EQUIPMENT INPUT - I - CCONNECTIFREQUIRED L -- OUTPUT TO CONNECT IF REQUIRED I - MIC-LEVEL BALANCED I EQUIPMENT INPUT L CONNECT IF REQUIRED CONNECT EITHER MIC OR LINE OUTPUT, NOT BOTH NOTE THAT INPUT CENTERTAP IS NOT INTERNALLY CONNECTED TO GROUND SPECIFICATION Height: 3.0 in 7.6 cm Width: 1.2 in 3.0 cm Depth (case): 1.5 in 3.8 cm Depth (with connectors): 1.8 in 4.6 cm Radio Design Labs Technical Support Centers U.S.A. (800) 933-1780, (928) 778-3554; Fax: (928) 778-3506 891-00681 Europe [NH Amsterdam] (++31) 20-6238 983; Fax: (++31) 20-6225-287 4. ....u.au. NO RDL :. ...;:::: SPECiALISTS IN PRACTICAL PRECISION ENGINEERINGT : Radio Design Labs ACCESSORIES Installation/Operation REAR RACK ADAPTER EN55103-1 Ell-El; EN55103-2 E1-E4 ( E Typical performance reflects product at publication time exclusive of EMC data, if any, supplied with product. FP-RRBI, ST-RRBI &M= Specifications are subject to change without notice. Step 2 Attach RRBI with appropriate module on to rear rack rail with supplied screws. Radio Design Labs Technical Support Centers 891-5214 U.S.A. (800) 933-1780, (928) 778-3554; Fax: (928) 778-3506 Europe [NH Amsterdam] (++31) 20-6238 983; Fax: (++31) 20-6225-287 DSB ACE-12 S SIGNAUNG LISTED 4—Velcro strap *- Tab for hanging keys or USB drives The DSB (Drawing Storage Box) is engineered using 18 gauge cold rolled steel and coated with a durable RED epoxy powder coat finish. A full length stainless steel hinge provides a long lasting durable construction. One inch tall lettering silk-screened with permanent white indelible ink on 2 sides provides a full 180 degrees of viewing for immediate identification to emergency responders. DRAWING STORAGE BOX The DSB (Drawing Storage Box) is an ideal solution to safely secure your critical building emergency plans such as evacuation and building layout drawings. In the event of an emergency, you are assured that responders will have immediate access to the proper drawings and information Business card required. A critical and responsible component to slots any EOP (Emergency Operation Plan). The DSB (Drawing Storage Box) securely holds up to a 4" diameter 36" tall Architectural roll of drawings. With an industry standard key lock, the cabinet provides secure storage from improper access or removal of critical documentation. An additional retainer inside the box holds drawings securely upon opening the door. This cabinet also Standard Features: Dimensions: 37" tall x 5 1/2 x 4 1,/4 deep Durable 18 gauge steel construction allows space to store other critical disks, USB Continuous stainless steel hinge drives, keys and contact information for the system. Color red, powder coat texture finish 1" white indelible lettering Standard key lock to secure documents Hold a 4" dia 36" long roll of drawings Storage locations for digital media, keys and contacts 800 fie F r~5-; : '~g g' p.- ISO 906f, Space Age Electronics, Inc. FAIMMEMM %J Made In U.S.A. . 486 1 723 Toll Fre 508.485.0966 Local 508 . 485 .0966 Local Space Age Electronics, Inc. 2013 508.485.4740 Fax ED0572 LT10597 Rev.B 1/2 No Excuses, Just Solutions! A A L L A A R R D D o a C C U U E E I I S S /,-,SPACEAGE LEECTRONICS, INC. C F F II R 0 R E E Specifications: The Drawing Storage Box (DSB) shall be UL listed, constructed of 18 gauge cold rolled steel (CRS), it shall be painted with a durable red powder coat paint. Over all dimensions 37" tall 5 1/2 wide and 4 ¼" deep. The access door shall be lettered on 2 angled sides of the cabinet providing 180 degrees of viewing. "FIRE ALARM DOCUMENTS" in White indelible letters minimum of 1" in height. The door shall have a stainless steel continuous piano hinge. The door of the DSB shall be locked with a keyed lock %" barrel. Inside the cabinet shall have a strap to secure drawing in cabinet that is adjustable for size of rolled drawings. Location to hold keys and secure emergency contact information safely inside cabinet for easy access. Ordering Information: Part # Description SSU00625 Drawing Storage Box (DSB) Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax 5 1/2" - S This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0572 LT10597 Rev.B 2/2 S S SimplexGrinnell LP t 3568 q!;17 Ruffin Road, South Sari Diego, CA 92123-259 7 Tele: (858) 633-9100 SimplexGrinnell Fax: (858) 633-9101 www.simplexgrinnell.com License Number 986047 L...• L :1 i1 SIMPLEXGRIN NELL LP 12728 SHOEMAKER AVENUE SANTA FE SPRINGS, CA 90670 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2017 This license is current and active. All information below should be reviewed. dO- ELECTRICAL . C16 -FIRE PROTECTION CONTRACTOR 1:Ilihi11Tiflf. :,, Contractors Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 10/01/2016 Bond of Qualifying Individual This license filed Bond of Qualifying Individual number 82332031 for MAYLE RONALD GILBERT in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82332035 for ROSTEN TIMOTHY PAUL in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 -WkCähèhsätidh This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC308342 Effective Date: 10/01/2016 Expire Date: 10/01/2017 Workers' Compensation History 5, 10/4/2016 REV.#: 0 PROJECT #: 480-X)O(XXX-XX / XXX.XX)OO(X tqcn Simplex Grinnell SimplexGrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 /02 Fax: (858) 633-9101 www.simplexgrinnell.com SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected WARRANTY SERVICE HOURS: S 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST 10/4/2016 REV.#: 0 PROJECT #: 480-XX)000(-)(X / )(XX)OO(XXX