Loading...
HomeMy WebLinkAbout2540 FARADAY AVE; ; FPC2021-0054; PermitPERMIT REPORT Print Date: 04/20/2022 Job Address: 2540 FARADAY AVE, CARLSBAD, CA 92010 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2091200100 Track#: Valuation: $0.00 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: OAKMONT -EMERGENCY RESPONDER RADIO COVERAGE FEE FIRE Plan Resub (3rd&Subsequent Submittal/hr) FIRE Special Equipment (Ovens, Dust, Battery) Special Equipment (Cityof Carlsbad Permit No: FPC2021-0054 Status: Closed -Finaled Applied: 04/15/2021 Issued: 11/15/2021 Finaled Close Out: 04/20/2022 Inspector: Final Inspection: FPContractor: CAL BUILDING SYSTEMS INC 3900 PROSPECT AVE, # B YORBA LINDA, CA 92886-1745 (714) 993-9650 AMOUNT $298.00 $417.00 Total Fees: $715.00 Total Payments To Date: $715.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov ERRCS Technical Booklet CAL-BUILDING SYSTEMS Fire/Life Snfety Access Control CCTV Phone Systeris Intercor1 SITE ADDRESS: 2540 FARADAY AVE. CARLSBAD, CA 92008 BOA LOCATION: 2ND FLOOR MPOE BOA MODEL & SN#: COMBA RX7W22-78B33348 SN# N/A CUSTOMER CONTACT: OAKMONT SENIOR LIVING CONTRACTOR CONTACT: JOHN CALVIN CAL BUILDING SYSTEMS (951) 640-9163 BILL OF MATERIALS -'1, .. .-. eflll \. ./ •· . . ,1 / IJiTJ'. CommScooe CELLMAX-0-CPUSEi Cell-Max Omnidirectional ln-BuildinR Antenna Svstem -69S-960 MHz and 1710-2700 MHz -N-Female 15 Laird Y80612 806-896 MHz 12-Element 11 dB Gold Anodized Yagi Antenna N/f 1 CommScooe Hl4RP-S0 1/2" Air Dielectric Plenum Rated (CATVPl, Hl Series-SO-ohm 1500 Times Microwave Svstems LMR-240-3.28ft SO Ohm· 3.28 ft LMR-240 Jumper Cable N-male to N-male 35 Times Microwave Systems LMR-240-3.28ft SO Ohm -3.28 ft LMR-240 Jumper Cable N-male tc:i N-female 35 CommScope LDF4-S0A 50 ohms -1/2" coaxial cable -foam dielectric 200 ft CommScool! L4TNM-PSA N for LDF4-50A Low Densitv Foam Dielectric Cable 50 Comba RX7W22-78AA3348 RX.1W22"288333it.lUiX7B\ll.~»• Class B Dual Band 700/800 Amolifier 48VDC 1 Comba DC-R06-0N300CIXHl IIN.Americal(Passive) 6 dB Directional Coupler, 698-2700 MHz, N-Female Connectors 7 Comba DC•R10-ON300CIXHl IIN.Americal!Passivel 10 dB Directional Coupler, 698-2700 MHz N-Female Connectors 2 Comba DC-R15-0N300C(XH) (N.Americal(Passive) 15 dB Directional Coupler, 698-2700 MHz, N-Female Connectors 1 Comba PS-R2-ONSOM(XH) l(N.America)(Passive) 2-Wav Wideband In-line Wilkinson Power Splitter 4 Newmar 1'~1.::: ., Newmar-.tl.EMA-4tlt:£ertified, NFPA compliant battery back up power 1 PolvPhaser CGXZ-+36NFNF-A 400-1200 MHz. DC PASS COAX PROTECTION, NFTO NF 1 DAS Alert 1221-B Dedicated Annunciator and Monitorimi Panel 1 Rohn ROHFRM125 60" x 1.25" OD Mast Flat Roof Non-Penetrating Mount 1 Rohn ROHFRMMAT Mat Kit for FRM Mounts (1 per) 42·1/2"x 36" x 1/8" Thick 1 CommScope 241088-1 Standard Grounding Kit for 1/2 in corrugated coaxial cable and elliptical waveguide180 and 220 1 HL4RPV-50 Product Classification Product Type Product Brand Product Series General Specifications Flexibility Jacket Color Dimensions Diameter Over Jacket Inner Conductor OD Outer Conductor OD Nominal Size Electrical Specifications Cable Impedance Capacitance de Resistance, Inner Conductor de Resistance, Outer Conductor de Test Voltage Inductance Insulation Resistance Jacket Spark Test Voltage (rms) Operating Frequency Band HL4-SO, HELIAX® Plenum Rated Air Dielectric Coaxial Cable, corrugated copper, 1/2 in, off white PVC jacket Air coaxial cable HELIA)(@ HL4-50A Standard Off-white 15.367 mm I 0.605 in 4.801 mm I 0.189 in 13.843 mm I 0.545 in 1/2 in 50 ohm±2ohm 75.459 pF/m I 23 pF/ft 1.476 ohms/km 0.45 ohms/kft 1.903 ohms/km 0.58 ohms/kft 4000V 0.19 µH/m I 0.058 µH/ft 100000 MOhms-km 5000V 1 -8800 MHz ' :, ' '; ~,,. :, ' ; '' ',, l-ID'.7-7 lt1'11t1'1@lil!)jlli. ~ ~ llt!JiU:, [{:l.~ll!C:W 00)~~ l[!MllflriIIJil!l') .. ®l 00'~ 'l~!1.ll¥.:lr" s!fl :t1,mm1,~ ,i1II ~lt!IillIDtl!> oo ~1l!Hiim;llJil"~ill!1.lI!1;. -" · ·· · · nlBlil ~n:ml .mrormlilli!r,, ~l!ilt11 ~ ill !~lj) · Page 1 of 5 HL4RPV-50 Peak Power Power Attenuation Pulse Reflection Velocity VSWR/Return Loss Frequency Band 700-894 MHz 806-960 MHz 1700-2200 MHz Attenuation Frequency (MHz) 1.0 1.5 2.0 10.0 20.0 30.0 50.0 85.0 88.0 100.0 108.0 150.0 174.0 200.0 204.0 300.0 400.0 450.0 460.0 500.0 512.0 600.0 VSWR 1.25 1.25 1.25 40kW 2.325 0.5% 88% Attenuation (dB/100 m) 0.211 0.259 0.299 0.673 0.957 1.177 1.529 2.011 2.048 2.188 2.278 2.705 2.924 3.147 3.18 3.903 4.554 4.853 4.911 5.138 5.205 5.675 Return Loss (dB) 19.1 19.1 79.1 Attenuation (dB/100 ft) 0.064 0.079 0.091 0.205 0.292 0.359 0.466 0.613 0.624 0.667 0.694 0.824 0.891 0.959 0.969 1.19 1.388 1.479 1.497 1.566 1.586 1.73 . -------· --~-·---· t~1 ~.,m .. ).1!!!ljr=i llill: a111~mill!i 11.~~,mtlfflllt,mfili~~'~ ,, ®i ~~•- 'l~:U'j l!l/ifi,m1n~ l.(flli!f-lr!f'J.lljjj&,M@~llil~{!Ill'~Mi1!00,_~ ,_,. -nu 1iW;!l .!l!JIMil mlt1ffllill@ll ~"I..r11 ltl!oc:roliIW iil mi,i · Average Power (kW) 36.18 29.51 25.54 11.34 7.97 6.48 4.99 3.79 3.73 3.49 3.35 2.82 2.61 2.42 2.4 1.95 1.68 1.57 1.55 1.48 1.47 1.34 Page 2 of 5 HL4RPV-50 700.0 6.176 1.882 1.24 800.0 6.648 2.026 1.15 824.0 6.758 2.06 1.13 894.0 7.07 2.155 1.08 960.0 7.357 2.242 1.04 1000.0 7.526 2.294 1.01 1218.0 8.407 2.562 0.91 1250.0 8.531 2.6 0.89 1500.0 9.461 2.884 0.81 1700.0 10.164 3.098 0.75 1794.0 10.483 3.195 0.73 1800.0 10.503 3.201 0.73 2000.0 11.163 3.402 0.68 2100.0 11.483 3.5 0.66 2200.0 11.798 3.596 0.65 2300.0 12.108 3.69 0.63 2500.0 12.714 3.875 0.6 2700.0 13.303 4.055 0.57 3000.0 14.159 4.315 0.54 3400.0 15.256 4.65 0.5 3600.0 15.788 4.812 0.48 3700.0 16.051 4.892 0.48 3800.0 16.311 4.971 0.47 3900.0 16.568 5.05 0.46 4000.0 16.824 5.128 0.45 4100.0 17.078 5.205 0.45 4200.0 17.329 5.282 0.44 4300.0 17.579 5.358 0.43 4400.0 17.827 5.433 0.43 4500.0 18.073 5.508 0.42 4600.0 18.317 5.583 0.42 4700.0 18.559 5.657 0.41 4800.0 18.8 5.73 0.41 4900.0 19.04 5.803 0.4 5000.0 19.277 5.875 0.4 Page 3 of 5 /I!l~ '>f!llllfl-!I;,.illl!, li1!],lil!.li1Er~ tmJ1l~~~ · <!Ii 00~'11;:i:lljfi;Jil;Tlll;Jl~• rc_:l;J!(,@IL>11ib~~••T•~~ ti.'111 Sl!L~~oo~\t!J ~mlllm!D--g d · · ·' ·· il@Ci! (lj!JH_:ffi.l 11lffiJ1UJilll!Tl> ~tl ~ fl1 ~ HL4RPV-50 6000.0 8000.0 8800.0 Material Specifications Dielectric Material Jacket Material Inner Conductor Material Outer Conductor Material 21.581 25.869 27.494 Mechanical Specifications Minimum Bend Radius, multiple Bends Number of Bends, minimum Number of Bends, typical Tensile Strength Bending Moment Flat Plate Crush Strength Environmental Specifications Installation temperature Operating Temperature Storage Temperature Attenuation, Ambient Temperature Average Power, Ambient Temperature Average Power, Inner Conductor Temperature Fire Retardancy Test Method Packaging and Weights Cable weight Regulatory Compliance/Certifications Agency Classification CATVP/CMP PE spline PVC 6.577 7.884 8.38 Copper-clad aluminum wire Corrugated copper 127 mm I 5 in 15 25 113 kg I 249.122 lb 4 ft lb I 5.423 N-m 1.429 kg/mm I 80 lb/in -5 °C to +60 °C (+23 °F to+ 140 °F) -20 °C to +80 °C (-4 °F to+ 176 °F) -20 ·c to +85 ·c (-4 °F to+ 185 °F) 68 °F I 20 °C 104 °F 40 °C 212 °F 100 °C NFPA 262/CATVP/CMP 0.253 kg/m I 0.17 lb/ft 0.35 0.29 0.28 c(ETL)us Certification ISO 9001 :2015 REACH-SVHC Designed, manufactured and/or distributed under this quality management system Compliant as per SVHC revision on www.commscope.com/ProductCompliance · ll!Wil 1llill1T1~ lfiE ,mJ,rftw~ ~ li1llif~t@1~•~ '' .i!ll 11.~@F{mJu~ 1.i.111•~~~~1@•~~ um;ilWmiitltilmliilill@il l~~ti;lffll Page 4of 5 HL4RPV-50 ROHS UL/ETL Certification Compliant CATVP/CMP tl!trl ~l!JlllilWDJJI=l !tl! ,i1Illll!Jitl§ ~~ 411J't~3!i :~~ I (!)'l 00>~ • r~!l:l.!lh'@l', :di~~ ~ !!fiI:OOIOOliru:tl!l ~Ill ~\I!:-~'IID\'WIWlllmill~ g lbM'I .,l!ffll t!l!Jmil1l <T•ffirn•Iilffili, 1~ [tl!r!l:.rulilw i. ll!m Page 5of 5 CriticalPoint™ Public Safety Bi-Directional Amplifier RX-7W22 Class B PS 7001800MHz BDA Features • Digital/programmable utilizing FPGA • Supports public safety 7001800MHz in single band or dual band version • Supports P25 P1/P2 digital and conventional analog communications simultaneously • Supports FirstNet™ L TE band 14 • Single band versions include license to switch from original band to alternate band • Single band can be upgraded to dual band via license key • Each band supports up to 3 wide band filters • 2W output power for each band • Built-in mandatory isolation test to prevent BDA oscillation • Auto shutdown with alarm upon oscillation detection • Web based GUI for intelligent configuration, SNMP supported • NFPA compliant dry contact alarms, NEMA 4X enclosure • FCC: PX8RX-7W22-B, IC: 11919A-RX7W22 • ,UL 60950-1 & UL 60950-22 Compliant Specifications Electrical Frequency Range, Uplink MHz Frequency Range, Downlink MHz Filter Bandwidth MHz Number of Filters Total Output Power, Uplink dBm Total Output Power, Downlink dBm Maximum System Gain dB Gain Adjustment Range (1dB step) dB Pass Band Ripple, p-p dB Uplink Noise Figure dB System Group Delay µsec Out-of-Band Suppression dBc Intermodulation dBm 9kHz to 1GHz dBm Spurious 1GHz to 12.75GHz dBm Maximum RF Input Power without Damage dBm Maximum RF Input Power without Overdrive dBm ALC Range dB lnputVSWR Impedance n © 2017 Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers' requirements. DS-Control: 1-2-2 / 0119 700MHz US: 788-805, CA: 798-806 US: 758-775, CA: 768-776 0.2-10 3 33 90 0-30 55 55 56.5 ~ 45 @ filter edge + 0.6MHz ~ 60@ filter edge+ 1 MHz 5 -13 FCC Compliance 10 -20 60 51.5 50 800MHz US:806-817, CA:806-824 US:851-862, CA:851-869 0.2-10 3 27 33 90 0-30 55 55 56.5 ~ 45 @ filter edge + 0.6MHz ~ 60@ filter edge+ 1 MHz 5-13 FCC Compliance 10 -20 60 51.5 50 Page 1 of 2 Mechanical Dimensions, H x W x D Weight (without bracket) Power Supply Power Consumption Enclosure Cooling RF Connectors Test Port Maximum Input for Dry Contact Port Operating Temperature Operating Humidity Environmental Class MTBF Outline Drawing Single band Dual band 390 tJ ti 0 "' I{) ----------J _ ___j_ Part Numbers Product Type Class B (US) Single band 700MHz Single band 800MHz Dual band 7001800MHz Class B (Canada) Single band 700MHz Single band 800MHz Dual band 7001800MHz License Dual Band (7001800MHz) License @2017 Comba Telecom. All rights reserved in(mm) lb{kg) VAC voe w w OF (OC) hr I --= I:--o ,11;11 ·O -0 :0: ~~---• -• ·0 0 0 210 165 PN (AC Version) RX7W22-078333AC RX7W22-088333AC RX7W22-788333AC RX7W22-C78333AC RX7W22-C88333AC RX7W22-CFB333AC Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers' requirements. OS-Control: 1-2-2 / 0119 ~ 0 0 "' 20.9 X 15.4 X 8.3 (530 X 390 X 210) 50.7 (23) 100-240/4 7-63Hz -40--58 80 100 Convection N-Female SMA, -22d8 24VDC, 1A / 110VAC, 0.5A -27 to +140 (-33 to +60) :,;95% NEMA4X .!: 100,000 @ 77 °F Note: Typical specifications at room temperature, PN (DC Version) RX7W22-07833348 RX7W22-08833348 RX7W22-78833348 RX7W22-C7833348 RX7W22-C8833348 RX7W22-CFB33348 RX7W22-L788333 Page 2 of2 Wideband Directional Coupler DC-Rxx-ON300C(XH) Low PIM(-153d8c), 698-2700MHz, N-Female, 300W • Wideband design covering 698-2700MHz • Available 5, 6, 7, 8, 10, 13, 15, 20, 30 & 40dB values • Suitable for indoor/outdoor environment • High Reliability and Low Insertion Loss Electrical Specification Product Model Frequency (MHz) Coupling (dB) Coupling Tolerance (dB) Loss (dB) Isolation (dB) VSWR @ Input port PIM (dBc) Average Power, max (W) Peak Power, max (W) Impedance (ohm) DC-ROS- ON300C (XH) 5.0 ±0.8 S 2.1 ~ 25 DC-R06-' DC-R07- ON300C ON300C (XH) (XH) 6.0 7.0 ±0.8 ±0.8 S 1.7 S 1.4 ~ 26 ~ 27 Mechanical Specification Dimension (in/mm) Weight (lb/kg) Connector Outline Drawing .,.-l "° lf) .... .,.-l (\J 0 6.2x2.4x0.8 / 158x61x21.5 0.75 /0.34 N-Female 0 122 158 ... I DC-ROS- ON300C (XH) 8.0 ±0.8 s 1.2 ~ 28 CC@m~@ DC-RtO-· DC-R13- ON300C ON300C (XH) (XH) 698-2700 10.0 13.0 ±0.8 ±1.0 S0.7 S0.5 ~ 30 ~ 33 Sl.25 <-153@ 2 x 43dBm 300 1000 50 DC-R1s-· ON300C (XH) 15.0 ±1.0 S0.4 ~ 35 keeps you connected ,. 1-comba - OC~flOIJ ------.......... , -----~ • • DC-R20-DC-R30- ON300C ON300C (XH) (XH) 20.0 30.0 ± 1.2 ±1.5 S0.3 S0.2 ~ 40 ~45 DC-R40- ON300C (XH) 40.0 ±1.5 S0.2 ~ 55 Environment & Compliance Application Operating Temperature Environment Relative Humidity RoHS Outdoor/ Indoor -40°c to +80°c IP65 Upto95% Compliant OS-Control 1-0-0/ 0316 Comba Telecom Inc. 235 Charcot Avenue, San Jose, CA 95131. http://www.combausa.com/ Tel: +1866 802 7961, combausa@comba-telecom.com, Fax: +1408 526 0181 Page 1 ofl Wideband Power Splitter PS-R2-ONS0M(XH) PS-R3-ONS0M(XH) PS-R4-ONS0M(XH) ~@ffi~©J keeps you connected 2/3/4 Way, Low PIM(-153dBc), 698-2700MHz, N-Female, 50W • Wilkinson power splitter • Wideband design covering 698-2700MHz • Suitable for indoor/outdoor environment • High reliability and low insertion loss Electrical Specification Product Model Frequency (MHz) Split Loss (dB) Insertion Loss (dB) Isolation (dB) PS-R2-ONS0M(XH) 2-Way VSWR @ all ports PIM (dBc) Average Power, max (W) Impedance (ohm) Mechanical Specification 3.0 $0.4 2: 20 $ l.20 Dimension (in/mm) 4.2lx3.llx0.87 / 107.0x79.0x22.0 Weight (lb/kg) 0.6 / 0.27 Connector Type N-Female Outline Drawing 0.87122I PS-R3-ONS0M(XH) 3-Way 698-2700 4.8 $0.6 2: 20 $ l.25 S -153@ 2 x 43dBm so so S.3lx4.37x0.87 / 135.0xlll.0x22.0 1.15/0.52 N-Female PS-R4-ONS0M(XH) 4-Way 6.0 $0.7 2: 18 2: 20 @800-2500MHz S l.30 S.08x5.55x0.87 / 129.0xl41.0x22.0 1.43/ 0.65 N-Female Environment & Compliance Application Operating Temperature Environment Relative Humidity RoHS Indoor/ Outdoor -2s·c to +8s0c IP65 Upto 100% Compliant OS-Control 1-0-1/0916 Comba Telecom Inc. 235 Charcot Avenue, San Jose, CA 95131. http://www.combausa.com/ Tel: +1 866 802 7961, combausa@comba-telecom.com, Fax: +1408 526 0181 Page 1 of 1 UL Certified Public Safety /BDA In-Building Coverage An integral pent of an in-building solution for emergency response radio coverage is the backup power system. NFPA codes relating to the autonomous operation and monitoring of the BDA power is quite stringent. These back up power enclosures were engineered to meet every aspect of NFPA 1221 and provide integrators configuration flexibility and rapid delivery directly to site, batteries included. Features ■ Certified to UL 924 (models with UL suffix) ■ NFPA Compliant • All Required monitoring alarms • Batteries included • Choose capacity to match system requirements • NEMA-4 Enclosure • Prewired with waterproof feed thru' s for easy on-site connections: ■ Customization to meet local AHJ 's requirements Enclosure A Specifications 12, 24, & 48V DC, 18 -lOOAH Input: 115/230 VAC (factory wired for 120V AC) Outputs: DC: 12, 24 and 48V, with 120, 240 and 480 Watt DC UPS AC: 11 0V at 96 watts -see reverse for detailed specifications Protections: Battery breaker, AC input breaker, NEMA enclosure, liquid tight cord grips NFPA 1221 Compliant Alarms (Form C, Dry Contact) ■ AC fail • Battery discharged to 30% of capacity • Charger fail Batteries Included: maintenance free, valve regulated, sealed lead acid, 18, 55, and 100 AH capacity Enclosure Size including Mounting Flanges (H x W x D): A: 30" x 23" x 10.5" B: 25" x 24" x 24" Model PE-12V-120W-18AH-UL PE-l 2V-l 20W-55AH-UL PE-l 2V-l 20W-100AH-UL PE-24V-240W-18AH-UL PE-24V-240W-55AH-UL PE-24V-240W-100AH-UL PE-48V-480W-18AH-UL PE-48V-480W-55AH-UL PE-48-480W-100AH PE-l 10V-100W-100AH/24V Output Voltage 12VDC 12VDC 12VDC 24VDC 24VDC 24VDC 48VDC 48VDC 48VDC ll0VAC *See revez:5e for battery specifications DC UPS Power Watts 18 55 60 36 110 120 72 200 480 96 ~~ m. Conlorms to NFP~ UL Standard MEMBER . 924 2018-2019 ' EnclosureB 48V, lOOAH Enclosure A: NEMA-4, UL listed, welded aluminum with IP 65 battery vent and locking door, 4 each 1/2" knock-outs for cable entry on sides and bottom (16 total), IP-68 cable entries. Red powder coat wall mount. Enclosure B: NEMA-4, welded aluminum with IP 65 vent, pad lockable door handle, 8 each 1/2" knock-outs for cable entry ( 4 ea. on bottom left and right), IP-68 cable entries. Red powder coat wall mount. Batt.A/H System w / Batt. Shipping Enclosure Capacity* Wt. (Lbs.) Wt. (Lbs.) Size 18 49 89 A 55 75 115 A 100 111 151 A 18 63 103 A 55 114 154 A 100 186 226 A 18 90 130 A 55 190 230 A 100 371 411 B 100 191 231 A UL: Models ETL Listed to UL Standard 924 __ n¥li_ll~_~9.~___;;,.r~....,;.;,..~=:-~.;;;;;;;;..· ---'--. ___ A_o_vvi_e_ri_in--=g the Net\Nork ~~@& ~ ™'4JI•Wl#i11~ o ~ JNJWPA Compllft©IDft JBaftfterry JBacJkaUp Power Battery Specifications Max Max Continuous Continuous Model Amp/Hour Battery Quantity Load 12 Hour Load Rating 24 Hour Rating 12VDC .. . f ESl 7-12S l 1.5A/18W .75A/9W PE-12V-120W-18AH-UL* PE-l 2V-l 20W_l55AH-UL* XP12-210FR l 4.6A/55W 2.33A/28W PE-12V-120Wf 100AH-UL* PYL12VlO0FS l 5A/60W 4.6A/55W j 24VDC ___ PE-24V-240Wf 18AH-UL* ESl 7-12S 2 1.5A/36W .75A/18W PE-24V-240W-~55AH-UL* XP12-210FR 2 4.6A/110W 2.33A/56W PE-24V-240Wt lO0AH-UL * PYL l 2Vl 00FS 2 5A/120W 4.6A/110W [48VDC __ _ -- PE-48V-480WT 18AH-UL* ESl 7-12S 4 1.5A/72W .75A/36W PE-48V-480W-55AH-UL * XP12-210FR 4 4A/192W 2.33A/112W I PE-48V-480WT l 00AH PYL12VlO0FS 4 8.5A/392W 4.6A/221W [ llOV A:C . . . --- PE-1 lOV-lOOWf 100AH/24V PYL12VlO0FS 4 N/A 96W Based on 100% duty cycle. Back-up time increase it intermittent duty cycle loads applied. * Certified to UL 924 Standards Typical Wiring Diagram Door Mounted Battery Disconnect AC Input Alarm Indicator Lights Alarm Contacts Breaker Disconnect Breaker B . . -\ . Electrolyte Content Pounds Gallons 1.9 0.3 7.6 0.8 22.8 1.6 3.9 0.6 15.2 1.6 45.7 3.2 7.7 1.3 30.5 3.2 91.3 6.3 ----I 91.3 6.3 BDS-DIN-UPS-48-10, DIN Rail DC UPS, 48V DC, 10 Amps 115V AC Jumper Manual Holder Battery(-) Battery Jumpers x 3 Battery(+) li~I.[~~!{~~! Povvering the Net;vvork ....-------------------------"'"" ~~@&~ ~ 0 ~ LDF4-50A TALLEY@ You Connect the World. We Make It Easy.• LDF4-SOA, HELIAX® Low Densitld Foam Coaxial Cable, corrugated ~ copper, 1/2 in, black PE jacket Product Classification Brand Product Series Product Type Standards And Qualifications EN50575 CPR Cable EuroClass Construction Materials Jacket Material Outer Conductor Material Dielectric Material Flexibility Inner Conductor Material Jacket Color Dimensions Nominal Size Cable Weight Diameter Over Dielectric Diameter Over Jacket Inner Conductor OD Outer Conductor OD Electrical Specifications Cable Impedance Capacitance de Resistance, Inner Conductor de Resistance, Outer Conductor de Test Voltage Inductance Insulation Resistance Jacket Spark Test Voltage (rms) Operating Frequency Band Peak Power HELIAX® LDF4-50A Coaxial wireless cable Fca PE Corrugated copper Foam PE Standard Copper-clad aluminum wire Black 1/2 in 0.15 lb/ft 0.22 kg/m 12.954 mm I 0.510 in 15.875 mm I 0.625 in 4.8260 mm I 0.1900 in 13.970 mm I 0.550 in 50 ohm ±1 ohm 23.1 pF/ft I 75.8 pF/m 0.450 ohms/kft I 1 .480 ohms/km 0.820 ohms/kft I 2.690 ohms/km 4000V 0.190 µH/m I 0.058 µH/ft 100000 Mohms•km 8000 V 1 -8800 MHz 40.0 kW page 1 of 4 October 11, 2018 LDF4-50A Velocity Environmental Specifications Installation Temperature Operating Temperature Storage Temperature General Specifications Ordering Note Mechanical Specifications Bending Moment Flat Plate Crush Strength Minimum Bend Radius, Multiple Bends Minimum Bend Radius, Single Bend Number of Bends, minimum Number of Bends, typical Tensile Strength Note Performance Note Standard Conditions 88% -40 °c to +60 °c (-40 °F to + 140 °F) -55 °c to +85 °c (-67 °F to + 185 °F) -70 °c to +85 °c (-94 °F to+ 185 °F) CommScope® standard product (Global) 3.8 N-m I 2.8 ft lb 110.0 lb/in I 2.0 kg/mm 127.00 mm I 5.00 in 50.80 mm I 2.00 in 15 50 113 kg I 250 lb Values typical, unless otherwise stated Attenuation, Ambient Temperature 20 °C I 68 °F Average Power, Ambient Temperature 40 °C I 104 °F Average Power, Inner Conductor Temperature 100 °C I 212 °F Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 680-800 MHz 1.13 24.30 800-960 MHz 1.13 24.30 1700-2200 MHz 1.13 24.30 2300-2700 MHz 1.13 24.30 You Connect the World. We Make It Easy.• page 2 of4 October 11, 2018 LDF4-50A TALL5Y@ You Connect the World. We Make It Easy.• Attenuation Frequency (MHz) Attenuation (dB/100 m) Attenuation (dB/100 ft) Average Power (kW) 0.5 0.149 0.045 40.00 0.211 0.064 36.11 1.5 0.259 0.079 29.46 2 0.299 0.091 25.50 10 0.672 0.205 11.35 20 0.954 0.291 7.99 30 1.172 0.357 6.51 50 1.521 0.463 5.02 85 1.995 0.608 3.82 88 2.031 0.619 3.76 100 2.169 0.661 3.52 108 2.256 0.688 3.38 150 2.673 0.815 2.85 174 2.887 0.88 2.64 200 3.103 0.946 2.46 204 3.135 0.956 2.43 300 3.835 1.169 1.99 400 4.462 1.36 1.71 450 4.749 1.447 1.61 500 5.021 1.53 1.52 512 5.085 1.55 1.50 600 5.533 1.686 1.38 700 6.009 1.831 1.27 800 6.456 1.968 1.18 824 6.56 1.999 1.16 894 6.855 2.089 1.11 960 7.124 2.171 1.07 1000 7.284 2.22 1.05 1218 8.11 2.472 0.94 1250 8.226 2.507 0.93 1500 9.093 2.771 0.84 1700 9.744 2.97 0.78 1794 10.039 3.06 0.76 1800 10.058 3.066 0.76 2000 10.666 3.251 0.72 2100 10.961 3.341 0.70 2200 11.251 3.429 0.68 2300 11.535 3.516 0.66 2500 12.09 3.685 0.63 2700 12.627 3.849 0.60 3000 13.407 4.086 0.57 3400 14.401 4.389 0.53 3700 15.118 4.608 0.50 4000 15.815 4.82 0.48 5000 18.01 5.489 0.42 page 3 of 4 October 11, 2018 LDF4-SOA 6000 8000 8800 20.055 23.826 25.244 • Values typical, guaranteed within 5% 6.113 7.262 7.694 TALLeV@ You Connect the World. We Make It Easy.• 0.38 0.32 0.30 Regulat□rld Compliance/Certifications Agency RoHS 2011/65/EU China RoHS SJ/T 11364-2006 ISO 9001 :2008 CENELEC Classification Compliant Below Maximum Concentration Value (MCV) Designed, manufactured and/or distributed under this quality management system EN 50575 compliant, Declaration of Performance (DoP) available L4TNM-PSA TALLEY@ You Connect the World. We Make It Easy.• T!:Jpe N Male Positive Stop™ for 1/2 in AL4RPV-50, LDF4-50A, HL4RPV- 50 cable Product Classification Brand Product Type General Specifications Interface Body Style Harmonized System (HS) Code Mounting Angle Ordering Note Electrical Specifications Connector Impedance Operating Frequency Band Cable Impedance 3rd Order IMO, typical • This product is part of the CommScope Wired for Wireless® Solution HELIAX® I Positive Stop™ Wireless and radiating connector N Male Straight 854420 (Coaxial cable and other coaxial electric conductors) Straight CommScope® standard product (Global) 50ohm 0-8800 MHz 50 ohm -116 dBm@ 910 MHz 3rd Order IMO Test Method Two +43 dBm carriers RF Operating Voltage, maximum (vrms) 707.00 V de Test Voltage 2000 V Outer Contact Resistance, maximum 0.30 mOhm Inner Contact Resistance, maximum 2.00 mOhm Insulation Resistance, minimum 5000 MOhm Average Power 0.6 kW@ 900 MHz Peak Power, maximum 10.00 kW Insertion Loss, typical 0.05 dB Shielding Effectiveness -130 dB page 1 of 3 September 26, 2018 L4TNM-PSA Outline Drawing MATES TO MIL-S'ID-3-48• 304.2 OR EQUIVALENT (1122.36mm) Mechanical Specifications Outer Contact Attachment Method Inner Contact Attachment Method Outer Contact Plating Inner Contact Plating Attachment Durability Interface Durability Interface Durability Method Connector Retention Tensile Force Connector Retention Torque Insertion Force Insertion Force Method Coupling Nut Proof Torque Coupling Nut Retention Force Coupling Nut Retention Force Method Dimensions Nominal Size Diameter G'" WRENCH FLATS 8.70mm Ring-flare Captivated Trimetal Silver 25 cycles 500 cycles IEC 61169-16:9.5 890 N I 200 lbf 19.0mm WRENCH FLAlS 5.42 N-m I 48.00 in lb 66.72 N I 15.00 lbf MIL-C-39012(-3.12, 4.6.9 4.52 N-m I 40.00 in lb 444.82 N I 100.00 lbf MIL-C-39012(-3.25, 4.6.22 1/2 in 22.35 mm I 0.88 in ~~.:~=~~~@·~. · .. ·• ~-. . .. , .... -~ . ~-:· ~~ ~<Jililtul'i~lltw€1l ~ · · · . TALL.EV@ You Connect the World. We Make It Easy.• page 2 of 3 September 26, 2018 L4TNM-PSA TALL5Y@ You Connect the World. We Make It Easy.• Length Weight 76.70 mm I 3.02 in 94.71 g 0.21 lb Environmental Specifications Operating Temperature Storage Temperature Immersion Depth Immersion Test Mating Immersion Test Method Water Jetting Test Mating Water Jetting Test Method Moisture Resistance Test Method Mechanical Shock Test Method Thermal Shock Test Method Vibration Test Method Corrosion Test Method Return Loss/VSWR Frequency Band 45-1000 MHz 1010-2200 MHz 2210-3000 MHz 3010-4000 MHz 4010-6000 MHz 6010-8000 MHz -55 °C to +85 °C (-67 °F to + 185 °F) -55 °C to +85 °c (-67 °F to + 185 °F) 1 m Unmated IEC 60529:2001, IP68 Unmated IEC 60529:2001, IP66 MIL-STD-202F, Method 106F MIL-STD-202, Method 213, Test Condition I MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C IEC 60068-2-6 MIL-STD-1344A, Method 1001.1, Test Condition A VSWR 1.02 1.03 1.05 1.09 1.25 1.33 Return Loss (dB) 39.00 37.00 33.00 27.00 19.00 17.00 Regulatory Compliance/Certifications Agency RoHS 2011/65/EU China RoHS SJ/T 11364-2006 ISO 9001 :2008 * Footnotes Classification Compliant by Exemption Above Maximum Concentration Value (MCV) Designed, manufactured and/or distributed under this quality management system Immersion Depth Immersion at specified depth for 24 hours Insertion Loss, typical 0.05v"freq (GHz) (not applicable for elliptical waveguide) ~W0Il~<Eilml ~~ . . . . . page 3 of 3 September 26. 2018 ====7 ]fnMES MlcRowAvE svsrEMs [b[Mi] [Rl® a~~(O) lrDce~a~a~ lb@w lb©>SS ~@mrilmrilMIJ'ilD~al~D@IJ'ilS ~©)al~ DdleaD goo-... • Jumper Assemblies in Wireless Communications Systems • Short Antenna Feeder runs ( e.g. WLL, GPS, LMR, Mobile Antennas) • Any application ( e.g. WLL, GPS, LMR, WLAN, WISP, WiMax, SCAD A, Mobile Antennas) requiring an easily routed, low loss RF cable LMR-240 Outdoor PE Black 54021 LMR-240-DB Outdoor/Watertight PE Black 54090 LMR-240-FR Indoor/Outdoor Riser CMR FRPE Black 54029 LMR-240-FR-PVC Indoor/Outdoor Riser CMR FRPVC Black 54214 LMR-240-PVC General Purpose PVC Black 54140 LMR-240-PVC-W General Purpose PVC White 54202 LMR-240-MA Indoor & Mobile Antenna PVC Black 54046 Inner Conductor Dielectric Outer Conductor Overall Braid Jacket Solid BC Foam PE Aluminum Tape Tinned Copper (see table) ~-~~ Installation Temperature Range Storage Temperature Range Operating Temperature Range -40/+185 -40/+85 -94/+185 -70/+85 -40/+185 -40/+85 •. . . ~ " 0 ~ ...... •· ~,~ •.. WA::VW§Jil(.!ff ·~ . ~~i(,:~(!t•l#'~ : OOl1lEl (00 (timOfi!f) Bend Radius: installation in. (mm) Bend Radius: repeated in. (mm) Bending Moment ft-lb (N-m) Weight lb/ft (kg/m) Tensile Strength lb (kg) Flat Plate Crush lb/in. (kg/mm) 0.75 2.5 0.25 0.034 80 20 (19.1) (63.5) (0.34) (0.05) (36.3) (0.36) . . • .. . . ... Velocity of Propagation Dielectric Constant Time Delay Impedance Capacitance Inductance Shielding Effectiveness DC Resistance Inner Conductor Outer Conductor Voltage Withstand Jacket Spark Peak Power 18 (800) TMS-COAX • www.timesmicrowave.com % 83 NA 1.42 nS/fl (nS/m) 1.21 ohms 50 pF/fl (pF/m) 24.2 uH/fl (uH/m) 0.060 dB >90 ohms/1000fl (/km) 3.2 ohms/1000ft (/km) 3.89 Volts DC Volts RMS kW ,(tmiil) 0.056 (1.42) 0.150 (3.81) 0.155 (3.94) 0.178 (4.52) 0.240 (6.10) (3.97) (79.4) (0.20) (10.5) (12.8) 1500 5000 5.6 cm OJ:! 100.0 jg 10.0 ::, .... C ._ CD G> = a. <(~ 1.0 10 Attenuation dB/100 ft Attenuation dB/100 m Avg. Power kW = ]/fnMES MICROWAVE svsrEMs ~ ~ ~~ 1.3 1.7 4.4 5.7 1.49 1.15 100 Frequency (MHz) 3.0 3.7 5.3 9.9 12.0 17.3 0.66 0.54 0.38 7.6 24.8 0.26 1,000 9.9 32.4 0.20 Calculate Attenuation = 10,000 10.9 11.5 12.9 20.4 35.6 37.7 42.4 66.8 0.18 0.17 0.15 0.10 24.3 79.7 0.08 (0.242080) • ✓ FMHz + (0.000330) • FMHz (interactive calculator available at http://www.timesmicrowave.com/cable_calculators) Attenuation: VSWR=1.0 ; Ambient= +25°C (77°F) Power: VSWR=1.0; Ambient= +40°C; lmer Conductor= 100°c (212°F); Sea Level; dry air; atmospheric pressure; no solar loading (800) TMS-COAX • www.timesmicrowave.com 19 -·1 ~ ]fnMES MICROWAVE svsrEMs [LfMi]~® a~~(Q) [FD ell:a [Q) D ~ lLCO>w [Less ~@ li'i1'il li'i1'il llll liil aca~ a CO> liils ~@a~ 1 2 0-~ 3 14~ (/ ' ~ r -~~~ ~: v ! ·~ .. , TC-240-FM-X -240-NMH-X • EZ-240-NMH-RA-X fJTC-240-NMH-RA-C 3190-2891 3190-2893 ' 3190-6143 3190-2426 ' I 7 5 C.1\~~ 6 ~ 8 ~ ' ,.. ©' "",._. \., , .. -~,, , TC-240-NMC ~ -· ----_,/ TC-240-NMH-X -EZ-240-1023M ... TC-240-NF-BH-X 3190-2887 3190-244 3190-6283 3190-2888 9 . ' 10~~~ 11 12-13 . --r ,,. ' t,"' ~" '"'" --c \)~ " . It:· ''I, -( \ . ~~\ ,. "- .~ '--".)--~ E2-~-BM-X/TC-,......-X TC-240-NF-PM-X I " 18 22 rH 3190-2889 ~~ ,j-:; ·• ;;;;; -..;;;;:: ~Ji,.-\ . ... f'i,., .\ TC-240-BM-RA-D 3190-2869 EZ-240-TM-RP-X 3190-2892 I -, TC-240-SM-RA-SS-X 3190-2900 30 ,,,,,,,,,.,,, .,..·C. tt:.,,p' 'f~ I . "'-· TC-240-MUHF 3190-445 I ~ 15 19 23 -27 I . - I 31 EZ-240-NF-X 3190-2795 . . -~ ~ ~-~-RA-X . ( .... , (§ EZ 3190-2868 ·,.Jr,~' . \i!-- EZ-240-QM-RA-X 3190-2895 ~ \ ~ ·-, ·•..,-;r • \ EZ-240-SM-RA-X 3190-2899 ~~,;::::, ~-....- -TC-240-716M 3190-2982 16 24 .' 28 .:;_. -. .,.. . \ ' TC-240-BMC 3190-242 C.- EZ-240-TM-X 3190-2725 .:·, )(j,,,--tr/~ .1--'-EZ-240-SM-X 3190-2897 ·-~ ~~~ TC-240-SM-RP 3190-326 "(>~,.. TC-240:716M-RA-D 3190~2983 .. I ...,190-6120. 3190-2890 17 . \. ~ ,~· ·-~~p:1 Cr:·-· ' 25 ., TC-240-TM-X 3190-2797 l c;s J. TC-240-SM-SS-X " -~ ,· 3190-2898 ___ .. ______ ~ -29 ~·~~ -(~ ... TC-240-SF-SS-BH-X 3190-2896 • @iifui afuW l ~••=-=--ml~ ramm> ~· r~ ~- 1-:-i=Male StraightP~TC-=2407Friil:x-31g(j:'21f91<1.25:1 (2.5) Knurl Solder Crimp N/G. 1.1 (28) 0.45 (11A)"o.OT4 (6.4) 2.NMale Straigh!Plug· EZ-240-NMH-X .3190-2893 <1.25:1 (2.5) Hex/Knurl SpringFinger Crimi:> A/G_ 1.5 (38.1) 0.78 (19.8) 0.086 (39.0) j 3. NMale RightAngle EZ-240-NMH-RA-X 3190-6143 <1.35:1 (6) Hex SpringFinger Crimp A/G 1 (25.1) 1.04 (26.4) 0,115 (52.0) I 20 (800) TMS-COAX • www.timesmicrowave.com = ](TIMES MICROWAVE SYSTEMS l ~ o J II If :.a~ (lilim ®!frilJ~ ~ b!I ~ ~ ~~-~ ~ \!i!li1@l1l ~ ~!lltill) ~ ~ -{©:ij) IThE ~ ~ iffllii llil ((illfil) fiD (llllil)) lliJ (©,) 4. NMale RightAngle TC-240-NMH-RA-D 3190-2426 <1.35:1 (6) Hex/Knurl Solder Crimp AJG 1.2 (32.4) 1.22 (31.0) 0.091 (41.7) 5.NMale Straight Plug TC-240-NMH-X 3190-2887' <1.25:1 (2.5) Hex/Knurl Solder Crimp NIS 1.5 (38) 0.75 (19.1) 0.086 (39.0) 6.NMale Straight Plug TC-240-NMC 3190-244 <1.25:1 (2.5) Knurl Solder Clamp SIG 1.5 (38) 0.75 (19.1) 0.082 (37.2) 7.1.0l2.3DIN Straight Plug EZ-240-1023M 3190-6283 <1.35:1 (2.5) knurl Spring Finger Crimp NIG 1.1 (228.5) 0.33 (8.5) 0.014 (6.63) 8. NFemale Bulkhead Jack TC-240-NF-BH-X 3190-2888 <1.25:1 (2.5) NA Solder Crimp A/G 1.7 (44) 0.88 (22.2) 0.115 (52.2) 9.NFemale Panel Mount TC-240-NF-PM-X 3190-2889' <1.25:1 (6) NA Solder Crimp A/G 1.7 (44) 0.88 (22.2) 0.115 (52.2) 10.NFemale Straight Jack EZ-240-NF-X 3190-2795 <1.25:1 (6) NA SpringFinger Crimp A/G 1.4 (35.4) 0.62 (15.8) 0.040 (18.0) 11.BNCMale Straight Plug TC-240-BMC 3190-242 <1.25:1 (2.5) Knurl Solder Clamp SIG 1.7 (43) 0.56 (14.2) 0.040 (18.1) 12.BNCMale Straight Plug EZ-240-BM-X 3190-6120 <1.25:1 2.5 Knurl SpringFinger Crimp A/G 1.3 (34) 0.58 (14.7) 0.043 (19.5) 13.BNCMale Straight Plug TC-240-BM-X 3190-2890 <1.25:1 (2.5) Knurl Solder Crimp A/G 1.3 (34) 0.58 (14.7) 0.043 (19.5) 14.BNCMale RightAngle TC-240-BM-RA-D 3190-2869 <1.25:1 (2) Knurl Solder Crimp A/G 1.0 (25.1) 0.57 (14.5) 0.115 (52.0) 15.BNCMale RightAngle EZ-240-BM-RA-X 3190-2868 <1.30:1 (4) KNURL Spring Finger Crimp A/G 1.3 (33.6) 1.19 (30.1) 0.091 (41.7) 16. TNCMate Straight Plug EZ-240-TM-X 3190-2725 <1.25:1 (2.5) Knurl SpringFinger Crimp NIG 1.4 (34.3) 0.59 (15.0) 0.043 (19.5) 17. TNCMale Straight Plug TC-240-TM-X 3190-2797 <1.25:1 (2.5) Knurl Solder Crimp NIG 1.7 (43) 0.59 (15.0) 0.043 (19.5) 18. TNC Male Reverse Polarity EZ-240-TM-RP-X 3190-2892 <1.25:1 (6) Knurl SpringFinger Crimp A/G 1.4 (36) 0.59 (15.0) 0.043 (19.5) 19.TNCMale RightAngle TC-240-TM-RA-D 3190-2798 <1.25:1 (6) Hex Solder Crimp A/G 1.0 (25.1) 0.62 (15.7) 0.115 (52.0) 20. TNC Female Straight Jack EZ-240-TF-X 3190-6204 <1.25:1 (6) NA Spring Finger Crimp A/G 1.1 (27.2) 0.87 (22.0) 0.033(15.0) 21. TNCFemale Reverse PolarityEZ-240-TF-RP-X 3190-6167 <1.35:1 (6) NA SpringFinger Crimp A/G 1.1 (27.2) 0.87 (22.0) 0.033(15.0) 22.QMAMale Straight Plug EZ-240-QM-X 3190-2894 <1.25: (6) Knurl SpringFinger Crimp NIG 1.2 (30.0) 0.41 (10.5) 0.014 {6.35) 23.QMAMale RightAngle EZ-240-QM-RA-X 3190-2895 <1.25: (<6) Knurl Spring Finger Crimp NIG 0.8 (20.3) 0.65 (16.5) 0.019 (8.62) 24.SMAMale Straight Plug EZ-240-SM-X 3190-2897 <1:25: (6) Hex Spring Finger Crimp NIG 1.0 (25.4) 0.32 (8.1) 0.016 (7.26) 25.SMAMale Straight Plug TC-240-SM-SS-X 3190-2898' <1.25:1 (10) Hex Solder Crimp SSIG 1.0 (25) 0.32 (8.1) 0.016 (7.3) 26. SMAMale RightAngle TC-240-SM-RA-SS-X 3190-2900' <1.35:1 (6) Hex Solder Crimp SS/G 0.8 (20) 0.65 (16.5) 0.019 (8.6) 27.SMAMale RightAngle EZ-240-SM-RA-X 3190-2899 <1.25:1 (6) Hex Spring Finger Crimp A/G 0.9 (22.8) 0.31 (7.9) 0.019 (8.6) 28.SMAMale Reverse PolarityTC-240-SM-RP 3190-326 <1.25:1 (2.5) Hex Solder Crimp SS/G 1.0 (25) 0.32 (8.1) 0.016 (7.3) 29. SMAFemale Bulkhead Jack TC-240-SF-SS-BH-X 3190-2896' <1.25:1 (2.5) NA Solder Crimp SSIG 1.1 (29) 0.31 (7.9) 0.019 (8.6) 130. Mini-UHF Straight Plug TC-240-MUHF 3190-445 <1.25:1 (2.5) Knurl Solder Crimp NIG 1.1 (28) 0.45 (11.4) 0.014 (6.4) 31. 7I16Din Male Straight Plug TC-240-716M 3190-2982 <1.35:1 (3) Hex Spring Finger Crimp A/S 2.0 (50.5) 1.26 (32.0) 0.186 (84.4) I 32. 7/16Din Male Right Angle TC-240-716M-RA-D 3190-2983 <1.35:1 (3) Hex Solder Crimp A/S 1.4 (34.3) 1.60 (40.6) 0.239 (108.5) .. •Finish metals: N=N1ckel, S=Silver, G=Gold, SS=Stamless Steel,A=Alballoy .,'VSWR. spec based on 3 footcablew1th a connector pair 'Available m bulk pack Ground Kit Weatherproof Kit CT-240/200I195/100 3190-667 wr.m Crimp Tool Strip Tool DeburrTool Cutting Tool Replacement Blade Replacement Blade Kit . . . GK-S240TT 3109-400 I. • • Standard Ground Kit (each) Weatherproof/Strain relief kit for LMR-240 WSB-240 3109-400 :~r: ~--4111! 3192-165 3192-152 3192-001 -~ ~ ii-1 ....... , •• 1., ~ Hllel1I CT-240/200/195/100 3190-667 Crimp tool for LMR-100, 195,200 and 240 connectors CST-240A 3192-152 Prep tool for LMR-240 connectors DBT-U 3192-001 Removes center conductor rough edges CCT-02 3192-165 Cable end flush cut tool RB-02 3192-166 Replacement blade for cutting tool RB-CST 3192-086 Replacement blade kit for all CST strip tools (800) TMS-COAX • www.timesmicrowave.com 21 CELLMAX-0-CPUSEI Cell-Max™ Omni In-building Antenna, 698-960 MHz and 1710-2700 MHz I Product Classification Product Type Product Brand General Specifications Application Antenna Type Antenna Array Characteristic Polarization Color Mounting Number of Ports Pigtail Cable Radome Material RF Connector Interface Dimensions Height Pigtail Length Outer Diameter In-building antenna Cell-Max'" Indoor Omni SISO Vertical White (RAL 9016) Thru-hole ceiling mount (optional) 1 670-141SXE, plenum rated ABS N Female 85 mm I 3.346 in 500 mm 19.685 in 186 mm 7.323 in ·1-litJ'il ~. ~ f.®ilID,"111J ~ ~ jjl; @I • ~ .· . • . • f C '•f ' .. [l.;j;f~i, (!ii lll!lmi~ ~~~~oo1lool ~~'1Y•··: •Ofil!D<Wot.;Dl!lli.~ !~ ~!il,~ • . . : \;'./'.~'., Page 7 of3 CELLMAX-O-CPUSEI Outline Drawing 50:1:J 018±3 Electrical Specifications Electrical Note Impedance Operating Frequency Band Electrical Specifications Frequency Band, MHz Gain,dBi Beamwidth, Horizontal, degrees VSWR I Return loss, dB 0186.4±3 85±.3 42±.3 500±20 ! INJECflON MOLDING PIM specifications are less than or equal to the stated value 50ohm 1710 -2700 MHz I 698 -960 MHz 698-800 800-960 2 2 360 360 1.8110.9 1.5114.0 •lID':1'1 ~llm ,m)~r~ 6.!0IJ@itiliitm!i:',~ .11 @ll · w~ •. 11.~.1, oo!~ ~~~1l!l-~i\!411m!ll~ ~~~jl,;.)1iV,/'.r-£ iifiliil~11iffiH.iililffiffii:t.~~/l1~ . . . ;_?·:•;\k•· 1710-2700 5 360 1.5114.0 CELLMAX-0-CPUSEI PIM, 3rd Order, 2 x 20 W, dBc Input Power per Port, maximum, watts -140 50 Environmental Specifications Operating Temperature Relative Humidity -40 ·c to +60 ·c (-40 °F to + 140 °F) Up to 100% Packaging and Weights Height, packed Width, packed Length, packed Packaging quantity Weight, gross Weight, net 135 mm 5.315 in 195 mm 7.677 in 195 mm 7.677 in 0.4 kg 0.882 lb 0.3 kg 0.661 lb Regulatory Compliance/Certifications Classification Below maximum concentration value -140 50 Agency CHINA-ROHS ISO 9001 :2015 REACH-SVHC ROHS Designed, manufactured and/or distributed under this quality management system Compliant as per SVHC revision on www.commscope.com/ProductCompliance Compliant ~~ -140 50 ,-------------------------------:----:-----:-:::-===:::-::-:-:::-:~==~Page3of3 -~Ji} ~!l=),lttl!. ,i'!)).il!Jil_l-:)1(~ a,n,;~~in, .. ·"11 ~ ~ ll_~~J,:!li~ ll!])i'J.!I'OOil!Iilll!Jll;}ifili>~~~ ~~•~ll1fil•lli@ •offl l!l!ll@m 11il1!Im!illt!r1i ~M.r.J ~ ©, ;gffl I . Laird. TECHNOLOGIES® r :t .... f r (~:_(:J .:A_ ~~ ~ ~~~ ~~~ www.la1rdtech.com -·· .~ ........ --~ ---------------.. - (""1 . I I I -1 ~ ~ -,•~ ____ -_----=---_ --~ =o. ---------=----....... - j I I -I '~l~ ~ 1l.i1Y11Q)i~ l~~m1 ~/~l>l ~!AW])~~ Model Frequency Range Gain Length Extended Length Voyager® ~HF Models • Field tunable for quick VG1502 150-174 MHz 2 dBi 55• 102" field deployment VG1325 132-150 MHz 5dBi 55• 102· • Rugged design performs VG1505 150-174 MHz 5 dBi 55• 102" in harsh environments VG1326 132-150 MHz 6d8i 55• 102· VG1506 150-174 MHz 6dBi 55" 102" • UV inhibiting insulators VG2002 200-225 MHz 2dBi 55• 102· = will not crack, decay, or ~HFMoctels disassemble with UV exposure VG4065 406-450 MHz 5dBi 25· 35" VG4505 450-512 MHz 5 dBi 25" 35" VG4506 450-512 MHz 6dBi 25• 35• Model Description Mast VG1505 and VG4505 shown ~-lMounting Options with optional FM2 FM1 Stainless Steel U Bolt Mount (2) 1 7/8" Mounting Kit FM2 Heavy Duty Base Mounting Bracket (2) 2 112· Model Frequency Elements Gain Front-Back Boom Boom Ratio Length Diameter ~oid Anoifize<! Non Weldecl VHF Models Directional Yagis Y1363 136-150 MHz 3 7.1 dBd 17 dB 41-1/2" 118" Y1365 136-150 MHz 5 9.2 dBd 20dB 12· 1-1/4" • 360 Fully Welded Gold Anodized mcdels Y1503 150-174 MHz 3 7.1 dBd 17 dB 41-1/2" 118" or value leader Silver Series available Y1505 150-174 MHz 5 9.2 dBd 20dB 72• 1-1/4" Y2203 220-250 MHz 3 7.1 dBd 17dB 41-1/2" 7/8" • Line up includes 3 element/7 .1 dBd gain Y2205 220-250 MHz 5 9.2 dBd 20dB 12· 1-1/4" to 18 element/14 dBd gain variations • Internal matching design will not ice up, ~olcl Ariodlied Fully Welclecl VHF Models* detune, or corrode YXXX3W User Defined 3 7.1 dBd 17 dB 41-1/2' 718" YXXX5W User Defined 5 9.2 dBd 20dB 12· 1-114" • VHF Custom tuning available *may require truck freight ,Gola AnoclizeoFull~ Wefded'0HF Moaels Y4065 406-430 MHz 5 9.2 dBd 20dB 37" 7/8" Y4066 406-430 MHz 6 10.2 dBd 20dB 44• 118" "1 Y4303 430-450 MHz 3 7.1 dBd 17dB 20-3/16" 1/8" ~ Y4305 430-450 MHz 5 9.2 dBd 20dB 37" 1/8" Y4306 430-450 MHz 6 10.2 dBd 20dB 44• 718" Y43012 430-450 MHz 12 11 dBd 20dB 68-1/16" 1-1/4" Y4503 450-470 MHz 3 7.1 dBd 17dB 20-3/16" 7/B" Y4505 450-470 MHz 5 9.2 dBd 20dB 37" 7/8" Y4506 450-470 MHz 6 10.2 dBd 20d8 44• 7/8" Y45012 450-470 MHz 12 11 dBd 20d8 68-1/16" 1-1/4" Y4705 470-490 MHz 5 9.2 dBd 20dB 37" 7/8" Y4706 470-490 MHz 6 10.2 dBd 20dB 44" 7/8" rGoia Anodized FuOy Weldeif 800/900 MHz Moclels Y8063 806-896 MHz 3 6dBd 15 dB 16-3/4" 118" Y8066 and Y8063 Y8066 806-896 MHz 6 9dBd 16dB 27-11/16" 118" shown with Y80612 806-896 MHz 12 11 dBd 20dB :48-7/8" 7/8" YM78HD Heavy Y8963 896-970 MHz 3 6dBd 15 dB 16314' 7/8" Duty Mounting Kit Y8966 896-970 MHz 6 9dBd 16dB 2711/16" 7/8" Y89612 896-970 MHz 12 11 dBd 20dB 48-7/8" 7/8" Y80618 806-896 MHz 18 14dBd 25dB 691/8" 1. Y89618 896-870 MHz 18 14dBd 25dB 69 7/8" 1· More Info: 800.323.3757 Items printed in green are in-stock and available for immediate delivery www.lairdtech.com B =============================~ COAXIAL RF SURGE PROTECTION (G}{ ~eJrrDeJS The GX Series of RF DC pass surge arrestors are engineered for RF coaxial applications where DC current is needed on the coaxial line. The GX Series can be used on GPS and other active antenna systems that operate in the range from DC to 2700 MHz. FEATURES • Frequency ranges from DC to 2.7 GHz • Patented hybrid surge protection • Repeatable RF performance after surge • Flexible bulkhead and bracket mounting options • Weatherproof when installed • 7/16' DIN, N-Type and TNC STANDARDS • Weatherproof: IEC 60529 IP 67 • Bellcore TA-NWT-000487 • Procedure 4.11, Wind Driven (120 MPH) • CE and RoHS PATENTED LIGHTNING ARRESTOR TECHNOLOGY The GX product family is based on PolyPhaser's patented hybrid protection technology. This hybrid circuit integrates the quick response of a silicon avalanche suppression diode (SASD) with the surge handling capabilities of a MOV and gas tube. The GX technology has been field tested for more than a decade and has been used in critical RF networks world-wide. SCHEMATIC GENERAL SPECIFICATIONS* Insertion Loss s0.1dB VSWR s 1.1 or Better Over Frequency Range Return Loss <26dB Max Operational Current 4A Typical Surge Withstand 20kA 8/20µs Waveform GXJ Bias-T SMA Connector as DC Injector 1st Three Identifiers Frequency Range AGX DCto50MHz BGX 40MHz to 400MHz CGX 400MHz to 1200MHz OGX 800MHz to 2500MHz Type Description E Extended Frequency H High Power J Bias-T w/ Injector Port z DC-Pass Connector Types Description D 7/16' DIN N N-Type T TNC Example of Naming Convention for GX Family** D GX J + 06 D M F -A Fraquency Series Type Positivity Voltage Surge Sida Surge Side Protected Side Lid Band Connector Connector Connector Configuration Type Gender Gender •confirm with product specific datasheet for detailed specifications *"Not all combinations available 1464-044 RevD ' Po!yPtiaser 2017 All rights reserved lt>Asatert NFPA-Compliant Iii Public Safety Radio Enhancement System Monitoring Unit and Annunicator Panel MEMBER DASalert Models 1221-A & 1221-B Meets NFPA-72 (2010, 2013 & 2016) and current NFPA-1221 codes for a Dedicated Annunciator and Monitoring Panel ~0®3 @oUfilij i!Ill!I3 0 Displays Status of: · BDA • Donor Antenna • AC Power • Battery Capacity • Battery Charger • System Status Includes Form-C relay contacts to interface with any fire alarm system Monitors communications link for integrity Includes independent circuitry to check antenna, AC power, battery capacity, charger and overall system status Mates with or augments monitoring of any BDA, antenna, charger, battery or UPS Low cost, easy to install and program Small size NEMA-4: 1 O"H x B"W x 4"D Backed up by internal battery (included) Easy installation to optional primary power sources: 48 VDC or 24 VDC, or 120 VAC Model 1221-A Monitor and Annunciator Panel 81-0heUonll Ampllller To Indoor Antennas Typical Application ~ Supply ................... .. .L 24-Hour Battery Backup ---BDA ---AC POWER 1----ANTENNA --+---SYSTEM ---CHARGER ---BATTERY '---COMM FAULT Fault Outputs to Fire Alarm System + ............ Optional DC Power 48 VDC or 24 VDC Code Requirements The current edition of the NFPA 1221 fire code (shown below) and NFPA-72 (2010, 2013 & 2016) describe the requirements for monitoring the performance of Public Safety in-building two-way Radio Enhancement Systems with a dedicated panel. This panel is required to be located in the fire command center but some jurisdictions require that it be located in the same room as the Radio Enhancement System. These panels are designed to meet all these requirements. In addition, Model 1221-A contains additional circuitry to enhance and augment the alarm sensing capabilities of the BDA and the DAS backup emergency power supply if they are not code compliant. Fault Signaling Relays Some DAS components are not configured with the appropriate Form-C alarm relays that can interface properly with all Fire Alarm Systems. This unit provides these alarm relays. They can be programmed to mate with any Fire Alarm System with their 'normally OFF' or 'normally ON' states for any 'fail safe' convention that is required by the Fire Alarm System. Enclosure & Power Requirements The enclosure is NEMA-4 rated consistent with the other requirements of the code and a small backup battery (included) inside the panel provides over 24 hours of service if this is needed to supplement loss of primary power. Primary power is provided by an AC socket-mounted 15 VDC power supply (included). Communication Integrity Per code, fault detection cables between the Radio Enhancement System and the panel are monitored to detect open circuits or short circuits to ground. If this condition is detected the panel will trigger a fault alarm to the Fire Alarm System signaling the loss of communications integrity. Antenna Monitoring (Model 1221-A) If the bi-directional amplifier (BOA) in the Radio Enhancement System does not have the capability to monitor donor antenna faults, the panel can provide this by adding external Bias-Ts in line with the antenna. The panel will detect common faults such as open circuits, short circuits, disconnected or severed cables leading to the antenna without impacting the RF performance of the system. Installation This panel provides an economical easy-to-install solution to meeting the code requirements and the flexibility to interface with and augment, if required, the fault detection and alarm signaling capabilities of a large variety of standard components used in these systems. The small size and light-weight enclosure can be wall-mounted into any installation. Model Comparison Module Model 1221 A Model 1221 B Annunciator System with FORM-C relay ✓ ✓ outputs to main fire alarm installation Alternative Donor Antenna Failure ✓ Sense Module (Bias-T fittings not included) Alternative DAS Battery Capacity Sense Module ✓ Alternative DAS Battery Charger Failure Sense Module ✓ Annunciator System Backup Battery (9 Ahr) ✓ ✓ Annunciator System Power Supply and Battery Charger ✓ ✓ Price $1600.00* $1100.00* • Prices shown are for standard 120 VAC powered models. Add $90 for 48 VDC or 24 VDC powered models. Models 1221 A and 1221 B Module Descriptions Annunciator System with FORM-C relay outputs to main fire alarm system (Models 1221A & Model 12218) This is the basic annunciator system that accepts ALARM signaling from external relays contained in the DAS equipment. The system accepts relay signaling indicating the following alarms: • Loss of AC Power • Amplifier Problems • Antenna Problems • DAS Battery Capacity below 30% • DAS Battery Charger Fail • Communications Faults • Summary System Alarm The annunciator system provides FORM-C dry relay contacts to provide alarm signaling with any fire alarm installation. The system will operate with DAS installations that include multiple amplifiers, antennas and power sources, and includes circuitry to detect communications faults (open or short circuits} with the DAS equipment. Annunciator System Backup Battery ): Both models are shipped with an 9 Ahr rechargeable SLA battery that mounts inside the enclosure to provide over 24 hours of backup power. Annunciator System Power Supply and Charger Both models are shipped with an external 15 VDC power supply and battery charger that can be connected to any 120 VAC power outlet. The battery charger includes indicators that show the health of the panel's backup battery. The need to replace this battery can be signaled to the building's main fire alarm system. Alternative Donor Antenna Failure Sense Module (Model 1221-A only) This module provides a means of detecting open circuit, short circuits, disconnected, severed or lose connector problems in the antenna feed from the donor. This circuitry utilizes external bias-T fittings (not included}. Multiple antennas can be connected in parallel to the same monitoring port. Model 1221 A should be used if your amplifier or other components in your installation do not have the means of detecting donor antenna problems. Alternative DAS Battery Capacity Sense Module (Model 1221-A only) If your installation has a backup battery to provide emergency DAS power in the event of an AC power failure it must be monitored to detect when it has less than 30 % capacity left to power the system when primary power is lost. Model 1221A should be used if your emergency power unit does not have this capability. Alternative DAS Battery Charger Failure Sense Module (Model 1221-A only) If your installation has a backup battery to provide emergency DAS power in the event of an AC power failure, the battery charger must be monitored to detect if it has failed or is degraded. Model 1221 A should be used if your charger unit does not have this capability. Excerpted from NFPA 1221 (2016 Edition): Similar requirements in NFPA-72 (2010, 2013, 2016) Standard for Installation, Maintenance, and Use of Emergency Services Communications System Dimensions Weight Form C Dry Relay Outputs to Fire Alarm System 9.6.13.2 Dedicated Panel. (1) A dedicated monitoring panel shall be provided within the fire command center to annunciate the status of all RF emitting devices and system component locations. The monitoring panel shall provide visual and labeled indications of the following for each system component and RF emitting device: (a) Normal ac power (b) Loss of normal ac power ( c) Battery charger failure (d) Low battery capacity (to 70 percent depletion) (e) Donor antenna malfunction (f) Active RF emitting device malfunction (g) System component malfunction (2) The communications link between the dedicated monitoring panel and the two-way radio communications enhancement system must be monitored for integrity. Specifications 10" X 8" X 4" Donor Antenna OK / Fail 11.7Ibs Fault inputs Amplifier OK / Fail from Radio Charger OK / Fail Enhancement System Battery Capacity OK / Low AC Power AC Power ON / OFF System (Summary Alarm) Donor Antenna Sense Amplifier (BDA) Analog Inputs DAS Battery+/- Antenna Battery Charger Certifications UL:E65324,ETL:4002961 Battery Capacity Communications Fault Power 120 VAC, 24 VDC or 48 VDC (100 mA max) ~ ~ ~11~ ~ =============================~ AVAILABLE GX PART NUMBERS -•:::,;~.'' .. ~~,,· ,_. -•. .'.,;.'i~ • " -··· . . , ~ ~.:.., ,_,;•,c-~ • . ,,:,; ·····-' . . ... : .--.. . · . .. ,-l~ ,--·""·,. ' •~-~---~.-.,• ~' ,,.,._ AGXZ +1 STFTF-A DC-SOMHz TNC 15V 1W S10QQµJ BGXZ-60NFNF-ALT 40MHz -400MHz N-Type 60V 100W s2.5mJ BGXZ-60NFNF-CNS 40MHz -400MHz N-Type 60V 100W S2.5mJ BGXZ-60NFNM-ALT 40MHz -400MHz N-Type 60V 100W S2.5mJ BGXZ-60NFNM-AS 5MHz -400MHz N-Type 60V 40W S2.5mJ CGXJ+15NFNF-A 400MHz -1.2GHz N-Type 15V 300W S25µJ CGXJ+36NFNF-A 400MHz -1.2GHz N-Type 36V 300W S25µJ CGXZ+15NFNF-A 400MHz -1.2GHz N-Type 15V 300W S50QµJ CGXZ+15NMNF-A 400MHz -1.2GHz N-Type 15V 300W S50QµJ CGXZ+36NFNF-A 400MHz -1.2GHz N-Type 36V 300W S150QµJ CGXZ +36NMNF-A 400MHz -1.2GHz N-Type 36V 300W S1000µJ DGXE+24DMDF-A 400MHz • 2.5GHz 7116" DIN 24V 600W S1mJ DGXE+30NMNF-A 650MHz-2.7GHz N-Type 30V 400W S1.5mJ DGXH+48DMDF-A 800MHz -2.5GHz 7116" DIN 48V 500W S146µJ DGXJ+24NFNF-A 800MHz -2.5GHz N-Type 24V 300W S25µJ DGXJ+24NFNM-A 800MHz -2.5GHz N-Type 24V 300W S25µJ DGXZ +06DFDF-A 800MHz -2.5GHz 7116" DIN 6V 300W S175µJ DGXZ+06DMDF-A 800MHz -2.5GHz 7116' DIN 6V 300W S175µJ DGXZ+06NFNF-A 800MHz -2.5GHz N-Type GV 300W S175µJ DGXZ+06NFNF-B 800MHz -2.5GHz N-Type 6V 300W S175µJ DGXZ+06NFNF-F 800MHz -2.5GHz N-Type 6V 300W S175µJ DGXZ+06NFNM-A 800MHz -2.5GHz N-Type 6V 300W S175µJ DGXZ+06NFNM-B 800MHz -2.5GHz N-Type 6V 300W S175µJ DGXZ+06NMNF-A 800MHz -2.5GHz N-Type 6V 300W S175µJ DGXZ+06NMNF-Z 800MHz -2.5GHz N-Type 6V 300W S175µJ DGXZ+06TFTF-A 800MHz -2.5GHz TNC 6V 300W S175µJ DGXZ+15DMDF-A 800MHz -2.5GHz 7/16'DIN 15V 300W S500µJ DGXZ+15NFNF-A 800MHz -2.5GHz N-Type 15V 300W S500µJ DGXZ+15NFNM-A 800MHz -2.5GHz N-Type 15V 300W S50QµJ DGXZ+15NMNF-A 800MHz -2.5GHz N-Type 15V 300W S500µJ DGXZ +15TFTF-A 800MHz -2.5GHz TNC 15V 300W S50QµJ DGXZ+15TFTF-BN 800MHz • 2.5GHz TNC 15V 300W S5QQµJ DGXZ+36NFNF-A 800MHz -2.5GHz N-Type 36V 300W S1.5mJ DGXZ +36NMNF-A 800MHz • 2.5GHz N-Type 36V 300W s1.5mJ DGXZ-60NFNF-A 800MHz • 2.5GHz N-Type 60V 300W s2.5mJ .. Measured under a 3kA 8/20us Waveform DIMENSIONS 2X N FEMALE COf<INECTORS MSX1.2~NUT <. FRM NON-PENETRATING The FRM mount is a lightweight mount and is galvanized for corrosion protection. The FRM mount is easily shipped via UPS. Order (1) optional FRMMAT (1/8"thick) or (1) optional FRMPAD (3/8"thick) for a protective barrier between the mount and the roof. Order (1) optional SCK150 safety cable kit (3/8" x 150'). Mount Part No. FRM125 FRM150 FRM166 FRM238 FRM225 FRM238SPS 16"Nomin MAST SPECIFICATIONS Mast Mast Description & Height Part No. FY202 1.25" 0.0. x 16 GA. x 5.0' (PG) FY203 1.50" 0.0. x 16 GA. x 2.5' (PG) FY204 1.66" 0.0. x 16 GA. x 2.5' (PG) FY205 2.38" 0.0. x 0.154" wall x 2.5' (HOG) FY205SP 2.25" 0.0. x 14 GA. x 5.0' (HOG) FY253 2.38" 0.0. x 0.154" wall x 5.0' (HOG) PG = Pre-galvanized mast HOG= Hot-dip galvanized mast 1.25" to 2.38" Mast Tube Diameters 2.5'and 5'Overall Mast Heights (See Mast Descriptions) FRM BALLAST REQUIREMENTS Effective Zero Vmax at centroid of projected area, (MPH) Ballast Velocity Vs Projected Area (EPA) (LBS) Load (MPH) (FP) (PSF) h=2FT h=3 FT h=4FT h=5 FT 100 12 140 135 110 96 85 2 200 24 198 188 153 133 119 300 36 242 222 182 157 (154) 141 (131) 400 48 280 269 219(197) 190 (154) 170(131) 100 12 99 96 78 68 60 4 200 24 140 133 108 94 84 300 36 171 157 129 111 99(93) 400 48 198 190 155 (139) 134(109) 120(93) 100 12 81 78 64 55 49 6 200 24 114 108 88 77 68 300 36 140 128 105 91 (89) 81 (76) 400 48 161 155 127(114) 110(89) 98(76) h = Distance from support surface to centroid of EPA. Vs= Effective wind velocity resulting in sliding on a flat surface with a .50 coefficient of friction. Vmax = Effective wind velocity based on strength or overturning. NOTE:The velocities in ( ) apply to the FRM125 mount when the _ ____ ___ _ -----~reng-tho~t~e~~Ml~-~mas~_g:v=~ ,R'fllll™Y;:)4~ ---Phone (369) 566-3000. Fax (309) 566-3079. www.rohnnet.com; The Industry Standard-~~.~-~ .. "-;/ c 2011 ROH~ PW-.JDUCf\ Lll Products LLC _ # 241088-1 Standard Grounding Kit for 1/2 in corrugated coaxial cable and elliptical waveguide 180 and 220 Product Classification Product Type Ordering Note General Specifications Bonding Conductor Jacketing Material Bonding Conductor Material Bonding Conductor Wire Size Cable Type Color Grounding Kit Type Grounding Strap Material Lug Attachment Lug Type Thread Size Dimensions Bonding Conductor Length Cable Jacketing Removal Length, maximum Cable Jacketing Removal Length, minimum Compatible Diameter, maximum Compatible Diameter, minimum Nominal Size Waveguide Size Electrical Specifications Grounding kit CommScope® non-standard product PVC Copper 6 gauge Corrugated I Elliptical waveguide Black Standard Grounding Kits Copper Factory attached Two-hole lug 3/8 in 609.6 mm 24 in 58.42 mm 2.3 in 55.88 mm 2.2 in 16.51 mm 0.65 in 15.494 mm I 0.61 in 1/2 in WR42 I WG20 I R220 I WR51 I WG19 I R180 ~i~~ Im, ,"11J ri{!Ji&~'1L=liJ mJ~~1~'l!i ~ '' ®"' <00 ~~~ .. ,., ,. , 1~•~®1~~,i'1ll~~®~•'lJllimillliD1JKil~.~~~ 11l!l,'ll li!IU!liU til~,m;tll!Ii) ~~ ~ ~ jDJi1!) Page 1 of 3 241088-1 Current Handling Current Handling Test Method Grounding, Bonding and Shielding Test Method Lightning Protection Test Method Material Specifications Rivet Material Environmental Specifications Operating Temperature Storage Temperature Blowing Rain Test Method Corrosion Test Method Freezing Rain/Icing Test Method Humidity Test Method Immersion Test Method UV Resistance Test Method Vibration Test Method Weatherproofing Method Packaging and Weights Height, packed Width, packed Length, packed Included Packaging quantity Weight, gross Regulatory Compliance/Certifications Classification Tested to withstand 100,000 amps peak current surge MIL-STD-1757 MIL-STD-188-124A IEC 1024-1 Copper -40 °c to +85 °c (-40 °F to + 185 °F) -40 °c to +80 °c (-40 °F to+ 176 °F) MIL-STD-810, Method 506 MIL-STD-1344, Method 1001 MIL-STD-810, Method 521 MIL-STD-1344, Method 1002 IEC 60529:2001, IP68 MIL-STD-810, Method 505 MIL-STD-202, Method 214 Butyl and electric tape 266. 7 mm 10.5 in 266. 7 mm 10.5 in 58.42 mm 2.3 in Grounding kit I Hardware I Lug I One roll of 2 in PVC tape I One roll of 24 in butyl rubber tape 0.72kg I 1.5871b Agency CHINA-ROHS ISO 9001 :2015 REACH-SVHC ROHS Below maximum concentration value Designed, manufactured and/or distributed under this quality management system Compliant as per SVHC revision on www.commscope.com/ProductCompliance Compliant ~'~~ 11m ,i1Jl,lij)i1l,,r--.i ,l11l~~~, ,, l!ll "00~~' (_"-'l!Sih•~ ,di ~'llIIID,\"-•l)l1> i:.'1ll 'f!lim~~oo;~\l!l ~ wtllmlll ~ ~ · • • · lf@il (!fil((;ffll ,titbnlilill@il ill:>'11C1ll!l '<)trill ~ ~ Page 2 of 3 241088-1 Included Products 42615-10 -Butyl Rubber Tape, 24 in 9905-71 -Black 2 in PVC Tape, 20 ft * Footnotes Grounding, Bonding and Shielding Test Method Military Standard for Grounding, Bonding, and Shielding: Bond Resistance Requirement of a Maximum de resistance of 0.001 ohm Lightning Protection Test Method Protection Against Lightning Electromagnetic Impulse, Table 1-Protection Level Ill-IV, 1995-02 Page 3 of 3 ------~---.. -:,.__'-'··~~-~·-·-·~··,.---~ ·+ ..... ·_..,_.' . ··,J:_,.,,;,, '· J ~'~~il11l~~,i11l~1!1~Dl)r~@ll"OO~~ .·.·.·., tl;Of~ <!ti~~ tl11l~or4rr.,m:,:imoo~ll!l·~ ~lmlll§ ~ ~lt!lr•: .• • llw.'lll!.ll8lml~~~!KJJD11il .