Loading...
HomeMy WebLinkAbout148 TAMARACK AVE; ; CBRA2019-0114; PermitPERMIT REPORT (city of Carlsbad Residential Associated Permit Print Date: 04/01/2022 Job Address: 148 TAMARACK AVE, CARLSBAD, CA 92008-4059 Permit Type: Parcel #: BLDG-Associated Permit Residential 2042530700 Valuation: $356,400.01 Work Class: Track#: Lot#: Permit No: CBRA2019-0114 Status: Closed -Finaled Single Family Detached Applied: 04/16/2019 Issued: 04/30/2020 Occupancy Group: Project#: DEV2016-0047 Finaled Close Out: 04/01/2022 Plan#: #of Dwelling Units: 1 Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: PC2019-0009 Plan Check#: Project Title: 148 TAMARACK AVENUE Description: PINPOKINTR: 2,152 SF LIV SFO WITH 200 SF DECK, 100 SF PATIO, & 631 SF GARAGE Applicant: JEFF PARSHALLE ARCHITECT JEFF PARSHALLE PO BOX 230132 ENCINITAS, 92023 (619) 985-4099 FEE DRAINAGE FEE PLDA B Medium Runoff WATER METER FEE 1" Displacement (P) GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION SB1473 GREEN BUILDING STATE STANDARDS FEE BUILDING PLAN CHECK FEE (BLDG) SWPPP PLAN REVIEW FEE TIER 1-MEDIUM SWPPP INSPECTION FEE TIER 1-Medium BLDG ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL STRONG MOTION-RESIDENTIAL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL BUILDING PERMIT FEE ($2000+) PUBLIC FACILITIES FEES -outside CFO Total Fees: $11,588.64 Total Payments To Date: $11,588.64 Inspector: Final Inspection: Balance Due: PDrei 02/08/2022 AMOUNT $589.80 $54.00 $175.00 $15.00 $1,076.84 $55.00 $246.00 $66.00 $46.33 $182.00 $92.00 $1,538.35 $7,452.32 $0.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov PERMIT INSPECTION HISTORY for (CBRA2019-0114) Permit Type: BLDG-Associated Permit Residenti; Work Class: Single Family Detached Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item BLDG-Structural Final BLDG-Electrical Final Friday, April 1, 2022 Application Date: 04/16/2019 Owner: COOWNER PINPOKINTR PAISAN AND CHIEM MIKO Issue Date: 04/30/2020 Subdivision: PALISADES Expiration Date: 08/08/2022 IVR Number: 18445 Address: 148 TAMARACK AVE CARLSBAD, CA 92008-4059 Inspection No. Inspection Primary Inspector Reinspection Inspection Status COMMENTS February 8. 2022: PV solar electrical rneter release to SDGE, electrical meter nurnber (6821387) -approved. February 8, 2022: PV solar electrical meter release to SDGE, electrical rneter number (6821387) -approved. Passed Yes Yes Page 10 of 10 Permit Type: Work Class: Status; Scheduled Date 08/23/2021 08/24/2021 02/03/2022 02/08/2022 PERMIT INSPECTION HISTORY for (CBRA2019-0114) BLDG-Associated Permit Residenti, Application Date: 04/16/2019 Owner: COOWNER PINPOKINTR PAISAN AND CHIEM MIKO Single Family Detached Issue Date: 04/30/2020 Subdivision: PALISADES Closed -Finaled Expiration Date: 08/08/2022 Address: 148 TAMARACK AVE IVR Number: 18445 CARLSBAD, CA 92008-4059 Actual Start Date Inspection Type Inspection No. Inspection Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency Status COMMENTS March 12, 2021: (inspection canceled by Steve Blackman contractor). June 1, 2021: 1. No electrical Deficiencies. 2. Temporary power pole service removed, electrical modified to permanent Electr·ical Service basis, for new dwelling and new ADU electrical-approved. 08/23/2021 BLDG-81 Underground Combo(11, 12,21,31) 164942-2021 Passed Tony Alvarado 08/24/2021 02/03/2022 02/08/2022 Checklist Item BLDG-21 Un d ergrou nd-U nderfloor Plumbing COMMENTS August 23, 2021: (Virtual inspection). 1. Underground plumbing domestic water and underground electrical conduit scope of work -approved. 2. Underground plumbing lines and underground electrical conduit, verified construction installation methods, per virtual inspection -approved. BLDG-31 Underground-Conduit Wiring August 23, 2021 (Virtual inspection). 1. Underground plumbing domestic water and underground electrical conduit scope of work -approved. BLDG-22 Sewer/Water Service Checklist Item 2. Underground plumbing lines and underground electrical conduit, verified construction installation methods. per virtual inspection -approved. 164927-2021 Cancelled Chris Renfro COMMENTS BLDG-Building Deficiency Cancelled TA completed on 8/23/2021 BLDG-Final Inspection 175929-2022 Partial Pass Tony Alvarado Checklist Item COMMENTS BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final BLDG-35 Solar Panel 176208-2022 Passed Tony Alvarado BLDG-Final Inspection 176209-2022 Passed Tony Alvarado Reinspection Passed No Yes Passed Yes Yes Reinspection Passed No Reinspection Passed Yes Yes Yes Yes Inspection Complete Incomplete Incomplete Complete Complete Friday, April 1, 2022 Page 9 of 10 PERMIT INSPECTION HISTORY for (CBRA2019-0114) Permit Type: BLDG-Associated Permit Residenti; Application Date: 04/16/2019 Owner: COOWNER PINPOKINTR PAISAN AND CHIEM MIKO Work Class: Single Family Detached Issue Date: 04/30/2020 Subdivision: PALISADES Status: Scheduled Date 03/11/2021 03/12/2021 03/15/2021 03/16/2021 06101/2021 Closed -Finaled Expiration Date: 08/08/2022 lVR Number: 18445 Address: 148 TAMARACK AVE CARLSBAD, CA 92008-4059 Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Status 03/11/2021 BLDG-34 Rough Electrical 152538-2021 Cancelled Tony Alvarado Checklist Item COMMENTS BLDG-Building Deficiency 03/12/2021 BLDG-34 Rough Electrical 152647-2021 Cancelled Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS March 12, 2021: (inspection canceled by Steve Blackman contractor). 03/15/2021 BLDG-18 Exterior Lath/Drywall 152759-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS March 15, 2021: (virtual inspection). No building Deficiencies. 1. Exterior stucco lath paper type of lath and stucco lath nailing pattern, and all penetrations sealed with silicone chaulking, scope of work-approved. 03/1612021 BLDG-84 Rough Combo(14,24,34,44) 152780-2021 Passed Tony Alvarado Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS 06/01/2021 BLDG-32 Const. 158596-2021 Passed Tony Alvarado Service/ Ag ri cultura l(Te mp) Checklist Item BLDG-Building Deficiency COMMENTS June1,2021· 1. No electrical Deficiencies-(TSPB). 2. Temporary power pole service removed, electrical modified to per111anent Electrical Service basis, for new dwelling and new ADU electrical-approved. BLDG-34 Rough Electrical 158595-2021 Passed Tony Alvarado Reinspection Inspection Reinspection Incomplete Passed No Reinspection Incomplete Passed No Complete Passed Yes Complete Passed Yes Yes Yes Yes Complete Passed Yes Complete Friday, April 1, 2022 Page 8 of 10 PERMIT INSPECTION HISTORY for (CBRA2019 ... 0114) Permit Type: BLDG-Associated Permit Residenti, Work Class: Single Family Detached Status: Closed -Finaled Application Date: 04/16/2019 Issue Date: 04/30/2020 Expiration Date: 08/08/2022 IVR Number: 18445 Owner: COOWNER PINPOKINTR PAISAN AND CHIEM MIKO Subdivision: PALISADES Address: 148 TAMARACK AVE CARLSBAD, CA 92008-4059 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS February 8, 2021: (virtual inspection) (Building Deficiencies). 1. Underground electrical, and low voltage data conduit, from p.o.c. Dwelling location to p_o_c_ to garage location, scope of work-not ready. February 9, 2021: (virtual inspection) (No Building Deficiencies). Approved. 1. Underground electrical, and (low voltage data) conduit, from p.o.c. Dwelling location to p.o.c. to garage location, scope of work-approved. 2. Informed Ryan contractor representative, electrical sub-panel and main electrical panel locations, must be verified and reflect SDGE Planner work order specifications. 03/05/2021 03/05/2021 BLDG-14 152074-2021 Failed Tony Alvarado Friday, April 1, 2022 Frame/Steel/Bolting/We lding (Decks) Checklist Item BLDG-Building Def1ciency COMMENTS March 5, 2020: (corrections). "building deficiencies". Stucco lath inspection needs to be conducted first. prior to rough frame combination inspection. Inform Steve general contractor. 1. Interior shear-wall does not connect or drag to existing perpendicular floor Joist. Structural engineer needs to provide a solution for missing drag strap connection of interior shear wall to upper area floor Joist blocking_ 2. Smoke detectors and carbon monoxide detectors missing at main dwelling unit and appropriate shed ceilings/sloped bedroom ceilings and secondary dwelling unit ADU smoke detectors needs to be relocated and (1) added. 3. Rough combination framing. electrical. mechanical, and plumbing scope of work, per plan-approved. 4. Electrical receptacles more than 12 feet distance in some areas in main dwelling unit and secondary ADU room areas. 5. Nail plates and window header beam and king post needs LPT4 metal connector for a positive connection. 6. Hot mop in bathroom shower enclosures knee to be under water leak proof test. 7. More corrections may follow. Passed No Yes Reinspection Incomplete Passed No Page 7 of 10 Permit Type: Work Class: Status: Scheduled Date 11/03/2020 02/08/2021 02/09/2021 PERMIT INSPECTION HISTORY for (CBRA2019-0114) BLDG-Associated Permit Residenti; Application Date: 04/16/2019 Owner: COOWNER PINPOKINTR PAISAN AND CHIEM MIKO Single Family Detached Issue Date: 04/30/2020 Subdivision: PALISADES Closed -Finaled Expiration Date: 08/08/2022 Address: 148 TAMARACK AVE IVR Number: 18445 CARLSBAD, CA 92008-4059 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Start Date Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency Status COMMENTS October 20, 2020: 1. partial pass sheer wall nailing pa!tern, type, holddowns, and metal connector clips -still need to be verified per framing contractor. 2. Holddowns and metal connectors appear to be missing in lo shearwall locations. October 19, 2020: 1. Partial pass -shearwall type/nailing pattern -partial pass. 2. Pending deputy inspectors report. 11/03/2020 BLDG-83 RoofSheating, 142771-2020 Exterior Shear (13, 15) Passed Tony Alvarado Checklist Item COMMENTS BLDG-13 Shear Panels-HD (ok November 3, 2020: to wrap) BLDG-15 Roof Sheathing-Re roof 1. Final shear wall inspection completed and approved. 2. Cesar/contractor will provide deputy inspectors report for shearwall type and shearwall nailing pattern. October 15, 2020: (Virtual inspection). 1. Roof sheathing for garage roof diaphragm area only. 2. Roof sheathing type/nailing pattern, per structural plans-approved. Passed Yes Yes Passed Yes Yes Inspection Complete 02/08/2021 BLDG-31 150061-2021 Failed Tony Alvarado Reinspection Incomplete Underground/Conduit • Wiring Checklist Item BLDG-Building Deficiency COMMENTS February 8, 2021: (virtual inspection) (No Building Deficiencies). 1. Underground electrical, and low voltage data conduit, from p.o.c. Dwelling location to p.o.c. to garage location, scope of work-not ready. 02/09/2021 BLDG-31 150135-2021 Partial Pass Tony Alvarado Underground/Conduit - Wiring Passed No Reinspection Incomplete Friday, April 1, 2022 Page 6 of 10 , PERMIT INSPECTION HISTORY for (CBRA2019-0114) Permit Type: BLDG-Associated Permit Residenti. Application Date: 04/16/2019 Owner: COOWNER PINPOKINTR PAISAN AND CHIEM MIKO Work Class: Single Family Detached Issue Date: 04/30/2020 Subdivision: PALISADES Status: Closed -Finaled Expiration Date: 08/08/2022 Address: 148 TAMARACK AVE IVR Number: 18445 CARLSBAD, CA 92008-4059 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency July 6, 2020: Yes 1. Slab steel reinforcement rebar per engineered plans-approved. 2. Approved to pour concre1e. 08/19/2020 08/19/2020 BLDG-66 Grout 135992-2020 Failed Peter Dreibelbis Re inspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Reds special inspection No 08/25/2020 08/25/2020 BLDG-66 Grout 136564-2020 Passed Peter Dreibelbis Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Reds special inspection Yes 08/2712020 08/27/2020 BLDG-66 Grout 136808-2020 Passed Peter Dreibelbis Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/04/2020 09/04/2020 BLDG-15 Roof/ReRoof 137592-2020 Passed Tony Alvarado Complete (Patio) 10/1412020 10/14/2020 BLDG-15 Roof/ReRoof 140958-2020 Cancelled Tony Alvarado Reinspection Incomplete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Cancelled No 1011512020 10/15/2020 BLDG-83 Roof Sheating, 141068-2020 Partial Pass Tony Alvarado Reinspection Incomplete Exterior Shear (13,15) Checklist Item COMMENTS Passed BLDG-15 Roof October 15. 2020: (Virtual inspection). Yes Sheathing-Reroof 1. Roof sheathing for garage roof diaphragm area only. 2. Roof sheathing type/nailing pattern, per structu ra I plans-approved. 10/19/2020 10/19/2020 BLDG-13 Shear 141286-2020 Partial Pass Tony Alvarado Re inspection Incomplete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency October 19, 2020: Yes 1. Partial pass -shearwall type/nailing pattern -partial pass. 2. Pending deputy inspectors report. 10/20/2020 10/20/2020 BLDG-13 Shear 141439-2020 Partial Pass Tony Alvarado Reinspection Incomplete Panels/HD (ok to wrap) Friday, April 1, 2022 Page 5 of 10 PERMIT INSPECTION HISTORY for (CBRA2019-0114) Permit Type: BLDG-Associated Permit_ Residenli, Work Class: Single Family Detached Status: Closed -Finaled Application Date: 04/16/2019 Issue Date: 04/30/2020 Expiration Date: 08/08/2022 IVR Number: 18445 Owner: COOWNER PINPOKINTR PAISAN AND CHIEM MIKO Subdivision: PALISADES Address: 148 TAMARACK AVE CARLSBAD, CA 92008-4059 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS June 25, 2020: 1. Verified compaction repot/letter of civil/geologist footing foundation bottoms for new Single family dwelling structure. 2. Foundation footing structural steel reinforcement rebar's approved for garage/structure -only. 3. Detached garage and ADU foundation/footing reinforcement steel re bar not per structural engineers footing detail-(failed footing steel inspection). June 10, 2020· 1. Footings reinforcement steel for new single-family dwelling not approved. 2. Footings Height and footing-form set backs to property lines certification from civil/surveyor required prior to footing inspection completed. 3. Civil engineer requires reinforcement steel rebar tight, size, and placement structural observation required prior to concrete pour and city footing inspection completion. June 23, 2020: 1. Verified compaction repotlletter of civil/geologist footing foundation bottoms for new Single family dwelling structure. 2. Foundation footing structural steel reinforcement rebar's approved for dwelling/structure -only. 3. Detached garage and ADU foundation/footing reinforcement steel rebar not per structural engineers footing detail-(failed footing steel inspection). June 16, 2020: 1. Foundation/slab footing reinforcement steel inspection-failed. 2. Soils engineer footing bottoms/slab compaction certification report required. 3. Surveyor setbacks to property lines, and concrete footing forms finished floor height certification required. 4. Structural observation report or third-party special inspector/deputy inspectors report for steel in footings type and placement required-(typical). 5. Structural engineers foundation footing details #3 and #5, on sheet SD-6, do not match as-built conditions. 07/06/2020 07/06/2020 BLDG-91 Complaints Inspection 131879-2020 Passed Tony Alvarado Friday, April 1, 2022 Passed Yes No Yes No Complete Page 4 of 10 PERMIT INSPECTION HISTORY for (CBRA2019-0114) Permit Type: BLDG-Associated Permit Residenti. Application Date: 04/16/2019 Work Class: Single Family Detached Issue Date: 04/30/2020 Status: Closed -Finaled Expiration Date: 08/08/2022 IVR Number: 18445 Owner: COOWNER PINPOKINTR PAISAN AND CHIEM MIKO Subdivision: PALISADES Address: 148 TAMARACK AVE CARLSBAD, CA 92008-4059 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS June 16, 2020: 1. Foundation/slab footing reinforcement steel inspection-failed. 2. Soils engineer footing bottoms/slab compaction certification report required. 3. Surveyor setbacks to property lines, and concrete footing forms finished floor height certification required. 4. Structural observation report or third-party special inspector/deputy inspectors report for steel in footings type and placement required-(typical). 5. Structural engineers foundation footing details #3 and #5, on sheet SD-6, do not match as-built conditions. June 23, 2020: 1. Verified compaction repotlletter of civil/geologist footing foundation bottoms for new Single family dwelling structure. 2. Foundation footing structural steel reinforcement re bar's approved for dwelling/structure -only. 3. Detached garage and ADU foundation/footing reinforcement steel rebar not per structural engineers footing detail-(failed footing steel inspection). June 10, 2020: 1. Footings reinforcement steel for new single-family dwelling not approved. 2. Footings Height and fooling-form set backs lo property lines certification from civil/surveyor required prior to footing inspection completed. 3. Civil engineer requires reinforcement steel rebar tight, size, and placement structural observation required prior to concrete pour and city footing inspection completion. 06/25/2020 06/25/2020 BLDG-11 131084-2020 Passed Tony Alvarado Friday, April 1, 2022 Foundation/Ftg/Piers (Rebar) Passed No Yes No Complete Page 3 of 10 Permit Type: Work Class: Status: Scheduled Date 06/23/2020 PERMIT INSPECTION HISTORY for (CBRA2019-0114) BLDG"Associated Permit Residenti: Application Date: 04/16/2019 Owner: COOWNER PINPOKINTR PAISAN AND CHIEM MIKO Single Family Detached Issue Date: 04/30/2020 Subdivision: PALISADES Closed -Finaled Expiration Date: 08/08/2022 Address: 148 TAMARACK AVE IVR Number: 18445 CARLSBAD, CA 92008-4059 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Start Date Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency Status COMMENTS June 10, 2020: 1. Footings reinforcement steel for new single-family dwelling not approved. 2. Footings Height and footing-form set backs to property lines certification from civil/surveyor required prior to footing inspection completed. 3. Civil engineer requires reinforcement steel rebar light, size, and placement structural observation required prior to concrete pour and city fooling inspection completion. June 16, 2020: 1. Foundation/slab footing reinforcement steel inspection-failed. 2. Soils engineer footing bottoms/slab compaction certification report required. 3. Surveyor setbacks to property lines, and concrete footing forms finished floor height certification required. 4. Structural observation report or third-party special inspector/deputy inspectors report for steel in footings type and placement required-(typical). 5. Structural engineers foundation footing details #3 and #5, on shee1 SD-6, do not match as-built conditions. Passed No No Inspection 06/23/2020 BLDG-11 130847-2020 Partial Pass Tony Alvarado Reinspection Incomplete Foundation/Ftg/Piers {Rebar) Friday, April 1, 2022 Page 2 of 10 Building Permit Inspection History Finaled (city of Carlsbad PERMIT INSPECTION HISTORY for (CBRA2019-0114) Permit Type: BLDG-Associated Permit Residenti; Application Date: 04/16/2019 Owner: COOWNER PINPOKINTR PAISAN AND CHIEM MIKO Work Class: Single Family Detached Issue Date: 04/30/2020 Subdivision: PALISADES Status: Closed -Finaled Expiration Date: 08/08/2022 Address: 148 TAMARACK AVE CARLSBAD, CA 92008-4059 IVR Number: 18445 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Date Start Date Status 05/22/2020 05/22/2020 BLDG.21 128333·2020 Partial Pass Peter Dreibelbis Reinspection Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency No 06/09/2020 06/09/2020 BLDG•11 129637 ·2020 Cancelled Peter Dreibelbis Re inspection F oun dation/Ftg/Piers {Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 06/10/2020 06/10/2020 BLDG•11 129721 ·2020 Failed Tony Alvarado Re inspection Foundation/Ftg/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency June 10, 2020: No 1. Footings reinforcement steel for new single-family dwelling not approved. 2. Footings Height and footing-form set backs to property lines certification from civil/surveyor required prior to footing inspection completed. 3. Civil engineer requires reinforcement steel rebar tight, size, and placement structural observation required prior to concrete pour and city footing inspection completion. 06/16/2020 06/16/2020 BLDG-11 130218·2020 Failed Tony Alvarado Reinspection Foundation/Ftg/Plers (Rebar) Friday, April 1, 2022 Inspection Incomplete Incomplete Incomplete Incomplete Page 1 of 10