HomeMy WebLinkAboutCDP 2021-0024; BLAUVELT RESIDENCE; GEOTECHNICAL INVESTIGATION FOR PROPOSED PREVIOUS TWO-STORY SINGLE FAMILY RESIDENCE; 2021-02-24Paul Blauvelt
1060 Northwood Drive
EAST COUNTY SOIL CONSULTATION
AND ENGINEERING, INC.
10925 HARTLEY ROAD, SUITE "I"
SANTEE, CALIFORNIA 92071
TEL. 619-258-7901
San Carlos, California 94070
February 24, 2021
Project No. 21-1106E6
Subject: Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Carlsbad, California 92008
Dear Mr. Blauvelt:
In accordance with your request, we have performed a geotechnical investigation at the subject site
to determine the geotechnical site conditions and provide recommendations for design and
construction of the proposed single-family residence.
SCOPE OF SERVICES
The following scope of work was performed for this investigation:
0 Site reconnaissance and review of published geologic and geotechnical reports and maps
pertinent to the project area.
0 Subsurface exploration consisting of drilling three test borings within the general area of the
proposed single-family residence. The test borings were logged by our project supervisor.
0 Collection of representative soil samples at selected depths. The obtained samples were stored
in moisture-resistant containers and transported to our soil testing laboratory for subsequent
analysis.
0 Laboratory testing of soil samples obtained during the subsurface exploration.
0 Geotechnical analysis of the field and laboratory data, which provided the basis for our
conclusions and recommendations.
0 Preparation of this report, which summarizes the results of our analysis and presents our
findings and recommendations for the proposed construction.
Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Carlsbad, CA 92008
SITE DESCRIPTION AND PROPOSED CONSTRUCTION
Page2
February 24, 2021
Project No. 21-1106E6
The site location is shown on the attached Vicinity Map, Figure 1. The site consists of a
rectangular-shaped, residential lot located on the west side of Lincoln Street, in Carlsbad,
California (see Figure 2). The lot is bordered by Lincoln Street to the east, an apartment complex
to the north and other homes to the west and south. The site is presently occupied by existing
residential buildings, which will be demolished.
The lot slopes gently down to the east. Site vegetation consists of grass, shrubs and a few trees.
The proposed construction consists of a two-story, wood framed, single-family residence. The
residence will be supported on continuous and/or individual spread footings and will have a slab-
on-grade floor.
SUBSURFACE EXPLORATION AND LABORATORY TESTING
The subsurface exploration consisted of drilling three test borings on February 3, 2021 to a
maximum depth of 6 feet with a hand auger. The approximate locations of the test borings are
shown on Figure 2. Logs of the test borings are shown on Figure 3.
Following the subsurface exploration, laboratory testing was performed on representative soil
samples to evaluate the pertinent engineering properties of the foundation materials. The
laboratory tests included moisture content, dry density and expansion index tests. The tests were
performed in accordance with ASTM standards. The test results are shown on the Logs of the Test
Borings, Figure 3 and on Figure 4, Results of Laboratory Tests.
SUBSURFACE SOIL CONDITIONS
The subsurface soil descriptions were interpreted from conditions encountered during the subsurface
exploration and/or inferred from the geologic literature. Detailed descriptions of the subsurface soils
are presented on the logs of the test borings presented on Figure 3. The following is a generalized
description of the soils.
Topsoil: Topsoil was encountered in the test borings to depths of 1.5 to 2 feet. The topsoil consisted
of dark brown, moist, loose and porous, silty sand with some small roots.
Slopewash: Slopewash was encountered below the topsoil to depths of 2.5 to 3 feet. The slopewash
consisted of reddish brown, moist, loose to medium dense, silty sand.
Terrace Deposits: Terrace deposits were encountered beneath the slopewash to the maximum depth
explored of 6 feet. The terrace deposits consisted of light reddish brown, moist, medium dense to
dense, silty sand.
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Carlsbad, CA 92008
GROUNDWATER
No groundwater was encountered in the test borings.
SOIL PROPERTIES
a. Compressible Soils
Page 3
February 24, 2021
Project No. 21-1106E6
Our field observations and testing indicate the topsoil and slopewash encountered to a depth of
about 3 feet are loose and compressible.
b. Expansive Soils
An expansion index test was performed on a representative sample of the slopewash. The
results of the test are shown on Figure 4. An expansion index of O was obtained, which
indicates the soils are non-expansive.
GEOLOGY
From published geologic maps, the site is underlain at depth by sedimentary terrace deposits.
There are no known geologic hazards such as landslides, liquefaction-prone areas, or earthquake
faults at the site. However, the proposed building is subject to ground shaking and possible
damage from earthquakes on nearby, or more distant, active faults .
SEISMIC DESIGN VALUES
Seismic design values are presented on Figure 5.
CONCLUSIONS
Construction of the proposed two-story residence is feasible from a geotechnical standpoint, provided
the recommendations presented in this report are properly implemented during construction.
RECOMMENDATIONS
SITE GRADING
a. Site Clearing
The area of the proposed construction should be cleared of vegetation, surface obstructions and
other deleterious materials. Vegetation and debris from the clearing operation should be properly
disposed of off-site.
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Carlsbad, CA 92008
b. Temporary Slopes and Excavations
Page 4
February 24, 2021
Project No. 21-1106E6
Temporary vertical slopes and excavations should not exceed 5 feet in height. Temporary slopes and
excavations greater than 5 feet in height should be shored or laid back at a maximum inclination of I : I
(horizontal to vertical). Recommendations for shoring design can be provided by our office if desired.
c. Soil Removals
Within the area of the proposed construction and to a distance of at least 5 feet outside building
limits, the loose topsoil and slopewash should be removed down to medium dense to dense terrace
deposits, an estimated depth of about 3 feet, and replaced with fill soils compacted to at least 90
percent relative compaction. Actual removal depths should be confirmed during grading by our
field representative.
d. Compaction and Method of Filling
Prior to fill placement, the exposed subgrade soils should be scarified to a depth of 6 to 8 inches,
moisture conditioned to slightly above optimum moisture content and compacted to at least 90
percent relative compaction.
The on-site soils may be reused as compacted fill, provided they are free of organic materials and
debris, and rocks or cobbles over 6 inches in dimension. Any imported fill soils should be
predominantly granular and approved by our field representative.
All fill should be compacted to a minimum relative compaction of 90 percent as determined by
ASTM D1557. Fill should be placed at a moisture content slightly above optimum moisture
content, in lifts 6 to 8 inches thick, with each lift compacted by mechanical means.
Utility trench backfill and retaining wall backfill should also be compacted to at least 90 percent
relative compaction.
All grading, fill placement, and compaction should be performed in accordance with the grading
requirements of the City of Carlsbad. Fill placement and compaction should be observed and
tested as necessary by our field representative.
EROSION CONTROL
Due to the sandy nature of the on-site soils, areas of recent grading or exposed ground may be subject
to erosion. During construction, surface water should be controlled via berms, gravel/sandbags, silt
fences, straw wattles, siltation or bioretention basins, positive surface grades or other method to avoid
damage to the finish work or adjoining properties. All site entrances and exits must have coarse
gravel or steel shaker plates to minimize offsite sediment tracking. Best Management Practices
(BMPs) must be used to protect storm drains and minimize pollution. The contractor should take
measures to prevent erosion of graded areas until such time as permanent drainage and erosion control
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Carlsbad, CA 92008
Page 5
February 24, 2021
Project No. 21-1106E6
measures have been installed. After completion of grading, all excavated surfaces should exhibit
positive drainage and eliminate areas where water might pond.
FOUNDATIONS AND FLOOR SLABS
• Continuous and/or individual footings should be founded in properly compacted fill at a
minimum depth of 18 inches below building pad grade or lowest adjacent, finished grade,
whichever is deeper.
• Continuous footings should be at least 12 inches wide and reinforced with a minimum of four
#4 steel bars, with two bars placed near the top of the footings and the other two bars placed
near the bottom of the footings. Individual footings should be at least 18 inches square and
reinforced with a grid of #4 bars spaced 12 inches on centers (each way) and placed on concrete
blocks at the bottom of the footing.
• An allowable soil bearing value of 2,000 pounds per square foot may be used for the design of
continuous and/or individual spread footings bearing in properly compacted fill soils. This
value may be increased by one-third for short term wind or seismic loads.
• For design purposes, total and differential settlements of½ inch may be assumed.
• Lateral loads in properly compacted fill may be resisted by an equivalent fluid passive soil
pressure of 300 pounds per cubic foot. A coefficient of friction of 0.35 may also be used. If
passive and friction values are used together, the passive value should be reduced by one-third.
• All footing excavations should be inspected and approved by our field representative. Footing
excavations should be thoroughly cleaned prior to inspection.
• Floor slabs, including garage slabs, should be at least 5 inches thick and reinforced with #4 bars
placed at 18 inches on centers in two directions in the middle of the slab. The reinforcing steel
should be supported on steel chairs or concrete blocks. Floor slabs should be underlain by 2
inches of clean sand over a 10-mil visqueen moisture barrier over 2 inches of clean sand. To
minimize the potential for shrinkage cracks, concrete should have a minimum compressive
strength of 3,000 psi and maximum water-cement ratio of 0.5. No special inspection of concrete
is required. Some shrinkage cracks are still possible.
SURFACE DRAINAGE
Surface water should not be allowed to pond next to buildings. Finished grades should slope a
minimum of 2 percent away from buildings and along drainage swales. Roof gutters and
downspouts connecting to solid, outlet pipes are recommended. Outlet pipes should be discharged
to an approved outlet.
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Carlsbad, CA 92008
LIMITATIONS OF INVESTIGATION
Page 6
February 24, 2021
Project No. 21-1106E6
Our investigation was performed using the skill and degree of care ordinarily exercised under similar
circumstances by reputable soil engineers and geologists practicing in this or similar localities. No
other warranty, expressed or implied, is made as to the conclusions and professional advice included in
this report. This report provides no warranty, either expressed or implied, concerning future building
performance. Future damage from geotechnical or other causes is a possibility.
This report is prepared for the sole use of our client and may not be assigned to others without the
written consent of the client and ECSC&E, Inc.
The samples collected and used for testing, and the observations made, are believed representative of
site conditions; however, soil and geologic conditions can vary significantly between exploration
trenches, test borings and surface exposures. As in most major projects, conditions revealed by
construction excavations may vary with preliminary findings. If this occurs, the changed conditions
must be evaluated by a representative of ECSC&E and designs adjusted as required or alternate
designs recommended.
This report is issued with the understanding that it is the responsibility of the owner, or of his/her
representative to ensure that the information and recommendations contained herein are brought to the
attention of the project architect and engineer. Appropriate recommendations should be incorporated
into the structural plans. The necessary steps should be taken to see that the contractor and
subcontractors carry out such recommendations in the field .
The findings of this report are valid as of this present date. However, changes in the conditions of a
property can occur with the passage of time, whether they are due to natural processes or the works of
man on this or adjacent properties. In addition, changes in applicable or appropriate standards may
occur from legislation or the broadening of knowledge. Accordingly, the findings of this report may
be invalidated wholly or partially by changes outside of our control. Therefore, this report is subject to
review and should be updated after a period of two years.
ADDITIONAL SERVICES
A review of plans and specifications, field observations and testing under our direction are integral
parts of the recommendations made in this report. If East County Soil Consultation and Engineering,
Inc. is not retained for these services, the client agrees to assume our responsibility for any potential
claims that may arise during construction. Observation and testing are additional services, which are
provided by our firm, and should be budgeted within the cost of development.
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Carlsbad, CA 92008
Page 7
February 24, 2021
Project No. 21-1106E6
This opportunity to be of service is appreciated. If you have any questions, or we can be of further
service, please do not hesitate to call or contact us.
Respectfully Submitted,
Martin R. Owen, PE, GE
Geotechnical Engineer
Attachments: Figures 1 through 5
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Carlsbad, CA 92008
FIGURE 1
VICINITY MAP
Carfsbad
State Beach
VILLAGE
-u-Std:~ f.l
DOWNTOWN CARLSBAD
9 32S9 Lincoln St,
Carlsbad, CA 92008
"·g -.1cc·-. Seafo~
& S~e?i<:'"~.
ii
BARRIO
NORTH BEACH
Page 8
February 24, 2021
Project No. 21-1106E6
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Carlsbad, CA 92008
FIGURE2
LOCATIONS OF TEST BORINGS
LEGEND
B-3 APPROXIMATE LOCATION OF TEST BORING
Page 9
February 24, 2021
Project No. 21-1106E6
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Carlsbad, CA 92008
DEPTH
Surface
1.5'
2.5'
6.0'
DEPTH
Surface
2.0'
3.0'
4.0'
DEPTH
Surface
2.0'
3.0'
5.0'
FIGUREJ
LOGS OF TEST BORINGS
TEST BORING B-1
SOIL DESCRJPTION
TOPSOIL
dark brown, moist, loose, porous, silty sand with rootlets
SLOPEWASH
reddish brown, moist, loose to medium dense, silty sand
TERRACE DEPOSITS
light reddish brown, moist, medium dense to dense, silty sand
bottom oftest boring, no caving, no groW1dwater
test boring drilled and backfilled 2/3/2021
TEST BORING B-2
SOIL DESCRJPTION
TOPSOIL
dark brown, moist, loose, porous, silty sand with rootlets
SLOPEWASH
reddish brown, moist, loose to medium dense, silty sand
TERRACE DEPOSITS
light reddish brown, moist, medium dense to dense, silty sand
bottom of test boring, no caving, no groundwater
test boring drilled and backfilled 2/3/2021
TEST BORING B-3
SOIL DESCRJPTION
TOPSOIL
dark brown, moist, loose, porous, silty sand with rootlets
SLOPEWASH
reddish brown, moist, loose to medium dense, silty sand
TERRACE DEPOSITS
light reddish brown, moist, medium dense to dense, silty sand
bottom of test boring, no caving, no groundwater
test boring drilled and backfilled 2/3/2021
Y = DRY DENSITY IN PCF
M = MOISTURE CONTENT IN %
Page 10
February 24, 2021
Project No. 21-1106E6
y M
114.3 11.0
y M
y M
100.2 10 .8
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Carlsbad, CA 92008
FIGURE4
RESULTS OF LABORATORY TESTS
EXPANSION INDEX TEST
(ASTM D 4829)
TEST INITIAL SATURATED INITIAL EXPANSION
LOCATION MOISTURE MOISTURE DRY INDEX
CONTENT CONTENT(%) DENSITY
(%) (PCF)
B-1 @ 2.0' 9.4 19.1 110.6 0
Page 11
February 24, 2021
Project No. 21-1106E6
EXPANSION
POTENTIAL
NON-
EXPANSIVE
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.
Geotechnical Investigation for Proposed Two-Story, Single-Family Residence
3259 Lincoln Street
Page 12
February 24, 2021
Project No. 21-1106E6 Carlsbad, CA 92008
FIGURE 5
SEISMIC DESIGN VALUES
3259 Lincoln St, Carlsbad, CA 92008, USA
Date
Design Code Reference Document
Risk Category
Site Class
Type Value
s, 1.094
51 0.395
s~,s 1.162
S'-": null -See Section 11.4 8
S:,s 0.775
S:: null -See Section 11.4.8
Type Value
SDC null -See Section 11.4.8
F. 1.062
Fv null -See Section 11.4.8
Description
Description
2/23/2021, 8:25:02 AM
ASCE7-16
D -Stiff Soil
C& ground mo ion. ( or 0.2 second period)
MCE~ ground motion. (for l.0s period)
Site-modified spectral acceleration value
Site-modified spectral acceleration value
Numeric seismic design value at 0.2 second SA
umeric seismic design ,alue at 1.0 second SA
Seismic design category
Stte amprtication factor at 0.2 second
Site amplification factor at 1.0 second
EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC.