Loading...
HomeMy WebLinkAbout1038 CAMINO DE LAS ONDAS; ; CBRA2017-0217; PermitBuilding Permit Finaled (city of Carlsbad Residential Associated Permit Print Date: 01/24/2023 Permit No: CBRA2017-0217 Job Address: 1038 CAMINO DE LAS ONDAS, CARLSBAD, CA 92011 Status: Closed -Expired Permit Type: BLDG~Associated Permit Residential 2145315400 Work Class: Single Family Detached Parcel#: Valuation: $392,444.15 Occupancy Group: #of Dwelling Units: 1 Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 4 3.0 GOLDEN SURF Track#: Lot#: 2 Project#: DEV13028 Plan#: Construction Type:VB Orig. Plan Check#: PC2017-0028 Plan Check#: Applied: Issued: Finaled Close Out: Final Inspection: 09/11/2017 11/01/2017 INSPECTOR: Burnette, Paul Frazee, Tim Wong, Cindy Collins, Michael Description: GOLDEN SURF: LOT 1 // PLAN 2 // 2,431 SF LIV// 463 SF GARAGE// 99 SF PATIO// 70 SF DECK Applicant: Property Owner: CoApplicant: NEW POINTE COMMUNITIES INC TYLER SANDSTROM 16880 W BERNARDO DR, # 230 SAN DIEGO, CA 92127-1614 (858) 254-9911 NEW POINT INVESTMENT 3S LLC 16880 W BERNARDO DR, # 230 SAN DIEGO, CA 92127 NEW POINT COMMUNITIES INC 16880 W BERNARDO DR, # 230 SAN DIEGO, CA 92127 FEE BRIDGE & THOROUGHFARE District 2 -Zone 20 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) COMMUNITY FACILITIES DISTRICT (CFD) FEE ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -inside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SEWER BENEFIT AREA FEES -L SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP INSPECTION TIER 1 -Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM SWPPP PLAN REVIEW TIER 1-Medium TRAFFIC IMPACT Residential Single Family w/in CFD WATER METER FEE 1" Displacement WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $47,627.51 Total Payments To Date: $47,266.51 Balance Due: Building Division EXPIRED PERMIT PERMIT HAS EXPl~;EO IN ACCORO;\NCE WITH C.B.C SECTION 106.4.4 AS A'-1EN0D flY C kC.18.04.020 DArE)1,LfJa_'??_ s1G'i.\TURt .. ~0£_J_~i:~~--P 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $19,280.00 $1,666.15 $473.00 $2,859.86 $66.00 $170.00 $92.00 $182.00 $7,142.48 $16.00 $5,029.00 $1,562.00 $934.00 $51.02 $238.00 $292.00 $56.00 $69.00 $2,800.00 $352.00 $4,169.00 $128.00 $361.00 Page 1 of 2 ' ' ,, PERMIT IN.,PECTION HISTORY for (CBRA2017-0217) Permit Type: BLDG-Associated Permit Residenti: Application Date: 09/11/2017 Owner: NEW POINT INVESTMENT 35 LLC Work Class: Single Family Detached Issue Date: 11/01/2017 Subdivision: PARCEL MAP NO 06136 Status: Closed -Finaled Expiration Date: 03/06/2019 Address: 1038 CAMINO DE LAS ON DAS IVR Number: 6277 CARLSBAD, CA 92011 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04117/2018 0411712018 BLDG-17 Interior 055191-2018 Failed Tim Frazee Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Need to patch pony walls and sides of the No shower 0412412018 04/2412018 BLDG-17 Interior 055907-2018 Passed Paul Burnette Comple!e Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Need to patch pony walls and sides of the Yes shower 0710312018 07/03/2018 BLDG-34 Rough 062962-2018 Passed Michael Collins Complete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency EMR emailed to SDGE Yes BLDG-Final Inspection 062963-2018 Failed Michael Collins Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 0813112018 BLDG-Fire Final 067653-2018 Rescheduled Cindy Wong Incomplete Checklist Item COMMENTS Passed FIRE-Building Final No 0910712018 09/07/2018 BLDG-Fire Final 069010-2018 Passed Cindy Wong Complete Checklist Item COMMENTS Passed FIRE-Building Final Yes 0911312018 09/1312018 BLDG-Final Inspection 069896-2018 Failed Paul Burnette Rei nspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No Tuesday, January 24, 2023 Page 2 of 2 Building Permit Inspection History Finaled (City of Carlsbad PERMIT INSPECTION HISTORY for (CBRA2017-0217) Permit Type: BLDG-Associated Permit Residenti, Application Date: 09/11/2017 Owner: NEW POINT INVESTMENT 35 LLC Work Class: Single Family Detached Issue Date: 11/01/2017 Subdivision: PARCEL MAP NO 06136 Status: Closed -Finaled Expiration Date: 03/06/2019 Address: 1038 CAMINO DE LAS ON DAS IVR Number: 6277 CARLSBAD, CA 92011 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 11/16/2017 11/16/2017 BLDG-21 040718-2017 Passed Paul Burnette Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 12/05/2017 12/05/2017 BLDG-11 042305-2017 Passed Paul Burnette Complete Foundation/Ftg/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/12/2018 02/12/2018 BLDG-15 Roof/ReRoof 048491-2018 Passed Paul Burnette Complete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/12/2018 03/12/2018 BLDG-14 051341-2018 Passed Tim Frazee Complete Frame/Steel/Bolting/We lding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/02/2018 04/02/2018 BLDG-84 Rough 053453-2018 Passed Paul Burnette Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 04/09/2018 04/09/2018 BLDG-18 Exterior 054266-2018 Passed Paul Burnette Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-23 054267-2018 Passed Paul Burnette Complete Gas/Test/Repairs Tuesday, January 24, 2023 Page 1 of 2 FIELD MEMO ADVANCED GEOTECHNICAL SOLUTIONS, INC. CLIENT: /v /) & 1 iaAGS P/W: {76/-/'5 DATE: /'2.-S;-~ 1'7 CLIENT'S REPRESENTATIVE: ,:;_ J~s PROJECT NAME: 0,-;(d_;,·· -~y~ --------------- PROJECT LocAT1ON: ~ v Is h,,q ,,,/ REPORT NO.: WEATHER: TRACT NO.: Footing/Caisson Excavation (Indicate as-built and design embedment depths, setback) Retaining Wall (Indicate type of wall, if drains installed per plan, limits of select backfill -if observed) D Presaturation (Indicate depth of presaturation and moisture content) D Subgrade (Specify curb and gutter, flatwork, or pavement) D Removal Bottom D Subdrain D Reinforcing Steel D Keyway Excavation D Special Inspection: ___________ _ D Concrete Testing D Other: _______________ _ CJ.,.,_._ I CJ t, '/ZA Zo 1-r 1!---t !:( 2 -{.l-,,,, I '2 C:5 IZA 2 o l--7 fl 'I 6 LIMITS OF OBSERVATION/ TESTING COVERED BY THIS NOTICE: (_)""'-# 3 C-tf~A -Z o / 1.-c• 2/ 7 -C/4... c;-c Ii' rz,A '2..<!t 7 -o z1 ~ {)1,,,,,,,,-1-4-c{ l-c-,j I It 2/ 15'3I C4oo c'vi s-J~ JI oCA-..f_ t<il -z /:r '214 ~ 3 I ~~0 " -C..1J~-ClsRA z,,11-oz 14- DESCRIPTION OF PROJECT AC,TIVITES/ T/STING: ··-. _____ < , __ Tl_ /4ha-.lA _ L cl,.. l;rcf/'<-.f hL-1, fJ2'1-1;) f-c,, / ~ CUA /:cv ~e./ {.,,A. tf,UL,t? l-"' it 'z.,,,,,c:-·y,vt<__.u,rd h II / a,.,_,1 a,,,,_, CiUL;l.c. I., (.__ +tv Pu 'Pv.t,z_ 14"(_•n·f-_ g0I lc.l~ cv-,J 1-rkl h~d L1 It___ Ct..£--, ,i,, c:t Cc;;~ c,,__ (.,., ;=I:~ cippv?JU So. l< /kp,vts, I ---73:i--.-z~z.-~--z:c, :1r -1-~1_q;,~;.:., ( Vcry t-;.,.,,.) --~ 1;J.1t~ fl?pi'ovd c;,,,; r 1~p,.yb SFri;VISllORS/FIRM: J4g;.5· 'f2cp,v/::;' 17<;/~/$-2 71;_,(;./J ----~------~--- 1 v -21-11 AGSTECHNI rw,_....._,.-----., 1 BILLED HOURS I --j i FIELD OFFICE TRAVEL I SIGNED: -----'=c:::__::::::,==::~--- PRINTED: __ 2_7i_-_V-< ___ ~-- ! PAGE -Lo~ memo2015.xlsx/Memo CLIENT'.S REPR~.ENTATIV~" SIGNED:9,) , PRINTED: ~----s TITLE: ___________ _ DATE: TO: PROJECT: PROJECT No.: MEMORANDUM November 30, 2017 Tyler Sandstrom Golden Surf 17-315 ~HTK STRUCTURAL ENGINEERS, LLP 14288 Danielson S!reet • Sute-#200 • Poway, CA92064-ffl19 (85B) ., .. ,... • WWW. HTI<SE.COM • Fax (658) B7._,959 The slab dowels shown in detail 2/SDl may be omitted if the slab and footing are poured monolithically. From: HTK Copies to: File Page 1 ~21 ;,. c ~z ~o ~ 0 z ., , ~ z c. , ~N ~~ l: = = F = ~ 4 u ~ D lll . O P l f .. . . . "" " " 1 . • ' -- - - I ~~ ~ !~~ ~; i I GO L D E N SU R F HO M E S ST R l ! l ! T AD D R l ! S S CA R D I F F , CA 92 0 0 7 I I H I 2 I _. J ~ I Il ii h -~ - ~ ' .. '' ~ ~ ~ >¥ = ~~ . 0: , S1 1 V M ,U : I O l S 31 ~ N I S ii ¥ ¼ @ll V M · O N O l : l ! S lm l i m I D !/ ) w .. 0 z U) w 5 0. . :Ii w , .. ~., _, C ~ 6 z 0 a: .. U) S1 1 V M 1: : 1 O O 1 . : l 0N O : > 3 S -• •- ;,! , .. ®ll V M - ~ N O ~ ! S 1! 2 ! 3 ' 4.0 "' w ,-0 z z 0 ~ w z z 0 0 w ,-:5 0.. 0. . 0 ,- r I SPEAR & ASSOCIATES, INC. NOVEMBER 27, 2017 CITY OF CARLSBAD ENGINEERING DEPARTMENT 1635 FARADAY AVENUE CARLSBAD, CA 92008-7314 RE: SETBACK CERTIFICATION GOLDEN SURF 1000 CAMINO DE LAS ONDAS CARLSBAD,CA DRAWING NO. 496-7A PROJECT NO. CT 13-04 CIVIL ENGINEERING AND LAND SURVEYING 475 PRODUCTION STREET SAN MARCOS, CA. 92078 (760) 736-2040 FAX (760) 736-4866 I HEREBY CERTIFY, THAT BY FIELD SURVEY ON NOVEMBER 22, 2017, THE BUILDING FORMS FOR THE ABOVE REFERENCED PROJECT AS SHOWN ON .DRAWING NO. 496-7 A, MEET THE MINIMUM SETBACK REQUIREMENTS AS SHOWN ON THE TABLE BELOW. SURVEY MONUMENTS AT THE PROPERTY CORNERS WERE LOCATED AND USED TO 'ESTABLISH THE MINIMUM BUILDING SETBACKS. FRONT YARD SIDE YARD REAR YARD LOT 1 SETBACKS N/A 10 20 RESPECTFULLY SUBMITTED, ~ RAY SPEAR PLS 6404 LOT 2 SETBACKS 10 7.10 14.2