HomeMy WebLinkAbout2290 COSMOS CT; ; CBC2022-0201; PermitBuilding Permit Finaled Commercial Permit Print Date: 02/01/2023 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 2290 COSMOS CT, CARLSBAD, CA 92011-1517 BLDG-Commercial Work Class: Tenant Improvement 2130504400 Track#: $1,697,615.00 Lot#: B Project#: Plan#: Construction Type:V-B Orig. Plan Check#: 547 2019 Yes Plan Check#: Permit No: Status: ( City of Carlsbad CBC2022-0201 Closed -Finaled Applied: 06/08/2022 Issued: 09/28/2022 Finaled Close Out: 02/01/2023 Final Inspection: 01/25/2023 INSPECTOR: de Roggenbuke, Dirk Kersch, Tim Renfro, Chris Description: REEF LIFESYLE: COM-Tl (36,500 SF) SECOND GENERATION ENTIRE BUILDING IMPROVEMENT Applicant: CHAMPION PERMITS TIM SEAMAN PO BOX 5955 CHULA VISTA, CA 91912 (619) 993-8846 FEE BUILDING PLAN CHECK Property Owner: LV COSMOS COURT LLC 2290 COSMOS CT CARLSBAD, CA 92011-1517 BUILDING PLAN REVIEW -MINOR PROJECTS (LDE) BUILDING PLAN REVIEW -MINOR PROJECTS {PLN) CERTIFICATE OF OCCUPANCY COMM/IND Tl -STRUCTURAL FIRE A-2 & A-3 Occupancies -Tl SB1473 -GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -COMMERCIAL (SMIP) Total Fees: $7,578.98 Total Payments To Date: $7,578.98 Balance Due: AMOUNT $2,210.65 $194.00 $98.00 $16.00 $3,826.00 $691.00 $68.00 $475.33 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov c·cityof Carlsbad COMMERCIAL BUILDING PERMIT APP LI CATION B-2 Plan Check eec.zo22-o:t.o·l Est. Value l'l, l., ",:\ Ci.ts-". 00 PC Deposit Jp '2r :,..\O •hC Date '-' -e'·L41'2-2- Job Address 2290 cosMos couRT, CARLSBAD, cA 92001 Tenant Name#: REEF LIFESTYLE, LLC Suite: APN: 213-050-44 -----· Lot#: Year Built: 1988 -------------- Year Built: 1988 ---Occupancy:_8 __ _ Construction Type:_v_-B __ Fire sprinklers0YESQNO A/C:0YESQNO BRIEF DESCRIPTION OF WORK: SECOND GENERATION TENANT IMPROVEMENT ENTIRE BUILDING CONSISTING OF: NEW PARTITIONS & CEILINGS. MODIFICATIONS TO EXISTING MECHANICAL, ELECTRICAL, PLUMBING INFRASTRUCTURE WITH SOME MINOR STRUCTURAL MODIFICATIONS EXISTING BUILDING IS DEMO'D IN WARM SHELL CONDITION, D Addition/New: ____________ New SF and Use, __________ New SF and Use _______ SF Deck, _______ SF Patio Cover, SF Other (Specify) ___ _ [i]renant Improvement: _____ SF, Existing Use: _______ Proposed Use: ______ _ _ 36_.s_oo_u_sF ___ SF, Existing Use: 8 Proposed Use: _8 ______ _ D Other: --------------------------------------- PRIMARY APPLICANT PROPERTY OWNER Name: ·, 1.,"""" SQ_,.c...__,J'<\ ._ ....._ Name: LV cosMos COURT. LLC c;o LUMINOUS CAPITAL MANAGEMENT Addres,_s_: _ __,Q,,......u--,i ...... c-• p:---S-°'-~---s.,,.....------Address: 8583 IRVINE CENTER DRIVE, SUITE 120 City:"C'nf!RLSBJ\D l.Xt\ .. ~ .. \j••-f State: CA Zip: -8 Ci.\ \1~ City: IRVINE State: CA Zip:._9_2s_1_8 ___ _ Phone:'~0-t:,1 2375 G '\..~-"\C...',, <t,-t'L~ Phone:949.670.4242 Email: l!avlt!.111,@reef.-, \1,,M @__ Email: Matt@LuminousCM.com c.).r._,a..,,~ \1,"-_ Q'l.(-."{'\,J':>1.. (..u.,.......__ DESIGN PROFESSIONAL Name: ID STUDIOS INC. Address: 23s s. SIERRA AVE .. suITE 110 CONTRACTOR OF RECORD Business Name: C2 BUILDING GROUP Address: 107 s CEDROS AVE, SUITE 1220 City: SOLANA BEACH State:_c_A __ Zip: 92075 City: SOLANA BEACH State:._c_A __ Zip: 92□75 Phone: 858-523-9836 Phone: 858-245-0271 Email: mcdonald@idstudiosinc.com Email: josh@c2bg.com Architect State License: _c_iD_#_6_10_4 _________ CSLB License#: 3, ~lo'-\,) lv Class: __ (5 ____ _ Carlsbad Business License# (Required): _______ _ APPLICANT CERTIFICATION: lcertifythatlhavereadthe applicationandstatethattheab veinformation is correct and that the information on theplansisaccurate. lagree to comply with all City ordinances and St e laws relating to building construction. NAME (PRINT): -~..;..1,.,~JY,,,,-->_JL_e.;..._· ,/V\ __ L_\J"'-.._. __ 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: 8uilding@carlsbadca.gov REV. 04/22 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I herebyaf firm under penaltyof perjurythat I am licensed underprovisionsof Chapter 9 (commencing with Section 7000) of Division 3 of the Businessand Professions Code, and my license is inf ul/ force and effect. I also affirm under penalty of perjury one of the following declarations{CHOOSE ONE): DI have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. Policy No. __________________________________________ _ -OR- F.;}T have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performa>,e of the work ~r V: ~ workers' compensati~ insurance carrier\and p_olicy nulll,_ber are: !nsuranceCompany Name: --, ""-"-1 iL Q..,( ".> t'(.., Policy No. \},,_, 'CJ ':i-. ~ 1 ~ l.l'e 'a-rt\\ & lo & Expiration Date: --'{.Q'-'--"....._._-'-7 ________ _ -OR- D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ ,my person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000,00, in addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code, Interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued {Sec. 3097 (i) Civil Code). Lender's Name: _______________________ Lender's Address: ______________________ _ CONTRACTOR CERT/FICA T/ON: The applicant certifies that al/ documents and plans clearly and accurately show aJ/ existing and proposed buildings, structures, access roads, and utilities/utility easements. Alf proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the pre ise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/eas ents, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately show nd labeled ell as all on-site grading/site preparation. All improvements existing on the property were completed in accordance with a/J regulations in existence at the time of their con NAME (PRINT): _\...;...,.;....~ __ s_0'-\,_-""'_c.-r--___ s1GNATuRe:---,!!~~-----oATE: ___ &;_\_1 __ l_0_a __ Note: If the person signing above is an authorized agent for the contractor provide a letter of a ______________________ _. (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License law). -OR- DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: AND, D FORM 8-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of theapplicablelaw, Section 7044of the Business and Professions Code, isavailableupon request when thisapplicationis submitted or at the following Web site: http:Ilwww.leginfo.ca.gov/calaw.html. OWNER CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately shaw all existing and proposed buildings, structures, access raads, and utilities/utility easements. AJJ proposed modifications ond/or additions are clearly labeled on the site plan, Any potentially existing detail within these plans inconsistent with the site plan are not approllf!d for construction and may be required to be altered or removed. The city's approve,/ of the application is based on the premise that the s11bmitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and /ram one another; access roods/easements, and utilities. The existing and proposed use of each building os stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grad;ng/site preparation. Ail improvements exiHing an the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. NAME (PRINT): SIGN: __________ DATE: _____ _ Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov 2 REV. 04/22 ' .. 7' ':t~~?"<, "" -RERMIT INSR-ECTION HISTORY fott ,(CBC2022-0201) Application Date: 06/08/2022 Owner: LV COSMOS COURT LLC Permit Type: BLDG-Commercial Work Class: Tenant Improvement Issue Date: 09/28/2022 Subdivision: PARCEL MAP NO 11589 Status: Closed -Finaled Expiration Date: 06/21/2023 IVR Number: Scheduled Actual Inspection Type Inspection No. Date Start Date Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS 01/25/2023 01/25/2023 BLDG-Final Inspection 201412-2023 Wednesday, February 1, 2023 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS 41184 Inspection Status Passed Address: 2290 COSMOS CT CARLSBAD, CA 92011-1517 Primary Inspector Reinspection Passed Yes No Yes No No Tim Kersch Passed Yes Yes Yes Yes Yes Inspection Complete Page 3 of 3 z~ ,, , PERMIT IN$PECTION HISJ'O~V for (CBC2022-0201) Permit Type: BLDG-Commercial Application Date: 06/08/2022 Owner: LV COSMOS COURT LLC Work Class: Tenant Improvement Issue Date: 09/28/2022 Subdivision: PARCEL MAP NO 11589 Status: Closed -Finaled Expiration Date: 06/21/2023 Address: 2290 COSMOS CT IVR Number: 41184 CARLSBAD, CA 92011-1517 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency Hard lids combo. No BLDG-14 No Frame-Steel-Bolling-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 11/18/2022 11/18/2022 BLDG-21 196964-2022 Passed Tim Kersch Complete Underground/LI nderflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 11/29/2022 11/29/2022 BLDG-24 Rough/Topout 197516-2022 Passed Tim Kersch Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 12/01/2022 12/01/2022 BLDG-85 T-Bar, Ceiling 197672-2022 Failed Tim Kersch Reinspection Incomplete Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Hard lids combo. No BLDG-14 No Frame-Steel-Bolting-Welding (Decks} BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 12/06/2022 12/06/2022 BLDG-27 Shower 198088-2022 Passed Tim Kersch Complete Pan/Tubs Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 12/20/2022 12/20/2022 BLDG-85 T-Bar, Ceiling 199170-2022 Cancelled Dirk de Roggenbuke Re inspection Incomplete Grids, Overhead 12/23/2022 12/23/2022 BLDG-85 T-Bar, Ceiling 199577-2022 Passed Dirk de Roggenbuke Complete Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency T-bar 2nd floor ok Yes 01/18/2023 01/18/2023 BLDG-Final Inspection 200836-2023 Partial Pass Tim Kersch Reinspection Incomplete Wednesday, February 1, 2023 Page 2 of 3 Building Permit Inspection History Finaled (City of Carlsbad ' ,"" "" " " PERMIT INSPECTION HISTORY for (G.P.~2~>.22-0201) Application Date: 06/08/2022 Owner: LV COSMOS COURT LLC Permit Type: BLDG-Commercial Work Class: Tenant Improvement Issue Date: 09/28/2022 Subdivision: PARCEL MAP NO 11589 Status: Scheduled Date 09/29/2022 10/11/2022 11/08/2022 11/16/2022 Closed -Finaled Expiration Date: 06/21/2023 Address: 2290 COSMOS CT CARLSBAD, CA 92011-1517 IVRNumber: 41184 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Start Date Status 09/29/2022 BLDG-14 192944-2022 Partial Pass Chris Renfro Re inspection Frame/Steel/Bolting/We lding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Partial pass rough framing and rough Yes electrical on first floor only. In walls. Second floor and restroom area pending BLDG-34 Rough 192946-2022 Partial Pass Chris Renfro Reinspection Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 10/11/2022 BLDG-84 Rough 193728-2022 Passed Tim Kersch Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topou1 Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 11/08/2022 BLDG-84 Rough 196038-2022 Failed Chris Renfro Reinspection Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready. Need fire sprinkler/overhead No inspection prior to building rough combo. Please address water leakage issues on first floor from copper piping and under storefront glass on southwest side. Call for rough combo when completed BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 11/16/2022 BLDG-85 T-Bar, Ceiling 196739-2022 Partial Pass Tim Kersch Reinspection Grids, Overhead Wednesday, February 1, 2023 Inspection Incomplete Incomplete Complete Incomplete Incomplete Page 1 of 3 Universal Engineering Sciences, 1441 Montiel Road, Suite 115 Escondido, CA 92026 p. 760.746.4955 I oneues.com FINAL REPORT FOR SPECIAL INSPECTION AND MATERIAL TESTING January 6, 2023 City Of Carlsbad Building Inspection Department 1635 Faraday A venue Carlsbad, CA 92009 CTE Project No. 4810.2200176 SUBJECT: SA TlSFACTORY COMPLETION OF WORK REQUIRING SPECIAL INSPECTION PERFORMED UNDER PERMIT NUMBER: CBC 20022-0201 PROJECT ADDRESS: 2290 Cosmos Coui1 (Reef Footwear Interior) J declare under pe11alty of perjury that, to the best of my knowledge, all of the work requiring special inspection and materials testing of reinforcing steel, epoxy anchors, structural concrete, expansion anchors, torque testing, and field welding has been completed. The inspected work for the structurc/s constructed under the sub1cct pe1111it is in confonnance with the approved plans, the inspection and observation program and other construction documents, and the applicable \Vorkmanship provisions of the applicable building codc/s. Executed on this sixth day of January 2023. TESTING LABORATORY OR SPECIAL INSPECTION AGENCY: CONSTRUCTION TESTING & ENGINEERING, INC 1441 MONTIEL ROAD SUITE l 15 FSCONDTDO, CA 92026 RESPONSIBLE MANAGING ENGINEER OF THE TESTING LABO RA TORY OR SPECIAL INSPECTION AGENCY: Dan T. Math State of California Registration Number: 61013 Expiration Date: 12/3 I /24 SfGNATURE: -------------- Geotechnica! Engineering I Construction Materials Testing & Inspections I Environmental Consulting Occupational Hea!th & Safety I Building Sciences 13\VE ENGINEER: D. Hansen DATE: June 1, 2022 PROJECT NUMBER: 13918A.2.00 STRUCTURAL • CIVIL • SURVEY • LAND PLANNING 9449 Balboa Avenue, Suite 270 •San Diego, CA 92123 Phone {619} 299-5550 • Fax {619} 299-9934 www.bwesd.com STRUCTURAL CALCULATIONS FOR REEF T.I. CITY SUBMITTAL 2290 COSMOS COURT CARLSBAD, CA 92011 Prepared for ID STUDIOS 236 S. SIERRA AVENUE, SUITE 110 SOLANA BEACH, CA 92075 > 1--0 B\VE STRUCTURAL • CIVIL • SURVEY • LAND PLANNING 9449 Ba/baa Avenue, Suite 270 •San Diego, CA 92123 Phone (619) 299-5550 • Fax (619) 299-9934 www.bwesd.com TABLE OF CONTENTS SEISMIC LOADS ................................................................................................................................... 1 WIND LOADS ....................................................................................................................................... 3 B1 ........................................................................................................................................................ 4 B2 ........................................................................................................................................................ 5 7 /S3.1 -Anchorage ............................................................................................................................ 6 Guardrail ........................................................................................................................................... 10 5/27/22, ·1:23 PM ATC Hazards by Location l\TC Hazards by Location Search Information Address: Coordinates: Elevation: Timestamp: Hazard Type: Reference Document: Risk Category: Site Class: 2290 Cosmos Ct, Carlsbad, CA 92011, USA 33.1224968, -117.2693568 257 ft 2022-05-27T20:21 :54.528Z Seismic ASCE7-16 II D-default Basic Parameters Name Value Description Ss 0.972 MCER ground motion (period=0.2s) S1 0.355 MCER ground motion (period=1.0s) Go gle SMs 1.167 Site-modified spectral acceleration value SM1 * null Site-modified spectral acceleration value Sos 0.778 Numeric seismic design value at 0.2s SA So1 * null Numeric seismic design value at 1.0s SA * See Section 11.4.8 •Additional Information Name Value Description soc * null Seismic design category Fa 1.2 Site amplification factor at 0.2s Fv • null Site amplification factor at 1.0s CRs 0.901 Coefficient of risk (0.2s) CR1 0.911 Coefficient of risk (1.0s) PGA 0.424 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.509 Site modified peak ground acceleration ,.,_•' ". '/ . ·. :::ii Temecula 0 Borrego Springs 0 Clevelanrl Anza-Bc National Forest Desl StLl\e f · San Diego v ' O Map data ©2022 Google, INEGI https://hazards.atcouncil.org/#/seismic?lat=33.1224968&Ing=-117 .2693568&address=2290 Cosmos Ct%2C Carlsbad%2C CA 92011 %2C USA 1/2 5/27 /22, 1 :23 PM TL 8 SsRT 0.972 SsUH 1.079 SsD 1.5 S1RT 0.355 S1UH 0.389 S1D 0.6 PGAd 0.5 • See Section 11.4.8 ATC Hazards by Location Long-period transition period (s) Probabilistic risk-targeted ground motion (0.2s) Factored uniform-hazard spectral acceleration (2% probability of exceedance in 50 years) Factored deterministic acceleration value (0.2s) Probabilistic risk-targeted ground motion (1.0s) Factored uniform-hazard spectral acceleration (2% probability of exceedance in 50 years) Factored deterministic acceleration value (1.0s) Factored deterministic acceleration value (PGA) 2 The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the focal Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are provided by the U.S. Geological Survey Seismic Design Web Services. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. https://hazards.atcouncil.org/#/seismic?lat=33.1224968&Ing=-117 .2693568&address=2290 Cosmos Ct%2C Carlsbad%2C CA 92011 %2C USA 2/2 5/27/22, 1:21 PM l\TC Hazards by Location Search Information Address: Coordinates: Elevation: Timestamp: Hazard Type: ASCE 7-16 MRI 10-Year MRI 25-Year MRI 50-Year MRI 100-Year Risk Category I Risk Category II Risk Category 111 Risk Category IV 2290 Cosmos Ct, Carlsbad, CA 92011, USA 33.1224968, -117.2693568 257 fl 2022-05-27T20:20:53.711 Z Wind ASCE 7-10 67 mph MRI 10-Year 72 mph MRI 25-Year 77 mph MRI 50-Year 82 mph MRI 100-Year 89 mph Risk Category I 96 mph Risk Category II 102 mph Risk Category Ill-IV 107 mph ATC Hazards by Location 72 mph 79 mph 85 mph 91 mph 100 mph 110 mph 115 mph Temecula 0 257 ft 3 Borrego Springs 0 Clevelaori Anza-Bc National Forest Des, State F · S~n Diego v · O Map data ©2022 Google, INEGI ASCE 7-05 ASCE 7-05 Wind Speed 85 mph The results indicated here DO NOT reflect any state or focal amendments to the values or any delineation lines made dwing the building code adoplion process. Users should confirm any output obtained from this tool with the local Authority Having Junsdiction before proceeding with design. Disclaimer Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. Per ASCE 7, islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area -in some cases, this website will extrapolate past the last wind speed contour and therefore, provide a wind speed that is slightly higher. NOTE: For queries near wind-borne debris region boundaries, the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne debris region. Mountainous terrain, gorges, ocean promontories, and special wind regions shall be examined for unusual wind conditions. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this wAhsih~ rlnP.s nnt imnlv ~nnrnv~I hv thA nnvP.rninn h11ilrlinn r.nrlA hnrliP.s rP.snnnsihlA fnr h11ilrlinn r.nrtP. ~nnrnv~I ~nrl intArnrAt~tinn fnr thA https://hazards.atcouncil.org/#/wind?lat=33.1224968&Ing=-117 .2693568&address=2290 Cosmos Ct%2C Carlsbad%2C CA 92011 %2C USA 1/2 Single 3-1/2" x 20" VERSA-LAM® LVL 1.8E 2650 DF FB01 (Flush Beam) I ~ASSED I BC CALC® Member Report Build 8410 Job name: Address: City, State, Zip: Customer: REEF 9449 Balboa Ave Ste 270 San Diego, CA, 921 .. .42 Dry I 1 span I No cant. May 27, 2022 13:17:15 File name: B-1 Description: Specifier: Designer: Dane Hansen Code reports: ESR-1040 Company: BWE (Burkett Wong Engineering) ~d I ! ! ! ! ! i ! ! ! ! ! ·rr1~ 1 1 r 1 1 1 1 1 + + + + + 0 + + + + + + + + ~ 16•09-00 B1 Total Horizontal Product Length= 16-09-00 Reaction Summary (Down/ Uplift) (lbs) Bearing Live Dead Snow Wind B1,2" 1716/0 705/0 B2,2" 1662/0 686/0 Load Summary Ta9 Description Load Trpe Ref. Start End 0 Self-Weight Unf. Lin. (lb/ft) L 00-00-00 16-09-00 1 U nf. Area (I b/ft2) L 00-00-00 16-09-00 2 Cone. Pt. (lbs) L 08-00-00 08-00-00 Controls Summary Value Pos. Moment 13103 ft-lbs End Shear 20761bs Total Load Deflection U1227 (0.162") Live Load Deflection U999 (0.116") Max Defl. 0.162" Span/ Depth 9.9 Bearing Supports Dim. (LxWl B1 Hanger 2" x 3-1/2" B2 Hanger 2" x 3-1/2" Cautions %Allowable 36.6% 15.6% 19.6% n\a 16.2% Value 2421 lbs 23481bs %Allow Support n\a n\a Header for the hanger Hanger is a Single 3-1/2" x 20'' LVL beam. Notes Design meets Code minimum (L/240) Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Hanger Manufacturer: Simpson Strong-Tie, Inc. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2009. Duration 100% 100% n\a n\a n\a %Allow Member 46.1% 44.7% Loe. Top Top Top Case 2 1 Material Hanger Hanger Live Dead 100% 90% 18 65 20 1200 420 Location 08-00-00 01-10-00 08-00-00 08-00-00 08-00-00 Calculations assume member is braced at ends. See engineering report for the unbraced length. Page 1 of 1 1 1 1 1 1 1 r 1 + + + + + l + + I ~ B2 Roof Live Snow Wind Roof Tributary Live 115% 160% 125% 00-00-00 02-00-00 n\a Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER® , AJS™, ALLJOIST®, BC RIM BOARD™, BCI®, BOISE GLULAM™, BC FloorValue®, VERSA-LAM®, VERSA-RIM PLUS® , Single 3-1/2" x 16" VERSA-LAM® LVL 1.SE 2650 DF FB01 (Flush Beam) IPsASSEDI BC CALC® Member Report Build 8410 Job name: REEF Address: City, State, Zip: Customer: Dry I 1 span I No cant. May 27, 2022 13:13:33 File name: 8-2 Description: Specifier: Designer: Dane Hansen Code reports: ESR-1040 Company: BWE (Burkett Wong Engineering) -----.----3 • • • • • I + + + + + :i: :i: :i: :i: + + + :i: :i: :i: + 0 + + + + :i: ~ 09--00-00 B1 Total Horizontal Product Length" 09..()0-00 Reaction Summary (Down/ Uplift) (lbs) • • + :i: :i: + Bearing Live Dead Snow Wind B 1, 2" 555 I O 235 / 0 B2,2" 1128/0 412/0 Load Summary Tag Descrietion Load T~ee Ref. Start End 0 Self-Weight Unf. Lin. (lb/ft) L 00-00-00 09-00-00 3 Trapezoidal (lb/ft) L 00-00-00 Controls Summary Value Pas. Moment 2558 ft-lbs End Shear 1438Ibs Total Load Deflection U999 (0.022") Live Load Deflection U999 (0.016") Max Defl. 0.022" Span/ Depth 6.6 Bearing Supports Dim. (LxW) B1 Hanger 2" x 3-1/2" B2 Hanger 2" x 3-1/2" Cautions %Allowable 8.4% 13.5% n\a n\a n\a Value 790Ibs 1540 lbs %Allow Sueeort n\a n\a Header for the hanger Hanger is a Single 3-1/2" x 16" LVL beam. Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Hanger Manufacturer: Simpson Strong-Tie, Inc. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2009. 09-00-00 Duration 100% 100% n\a n\a n\a %Allow Member 15.0% 29.3% Loe. Top Front Case 1 1 1 2 Material Hanger Hanger Live Dead 100% 90% 14 0 0 374 115 Location 05-01-14 07-06-00 04-09-06 04-09-06 04-09-06 Calculations assume member is braced at ends. See engineering report for the unbraced length. Page 1 of 1 + l :i: l + + 1 1 I + + :i: :i: :i: :i: • + ~ . --er 82 Roof Live Snow Wind Roof Tributary Live 115% 160% 125% 00-00-00 n\a Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJS™, ALLJOIST®, BC RIM BOARD™, BCI®, BOISE GLULAM™, BC FloorValue® , VERSA-LAM®, VERSA-RIM PLUS® , ,:,,s., Hilti PROFIS Engineering 3.0.78 www.hilti.com Company: Address: Phone I Fax: Design: Fastening point: Specifier's comments: 1 Input data Anchor type and diameter: Item number: Effective embedment depth: Material: Evaluation Service Report: Issued I Valid: Proof: Stand-off installation: I Concrete -May 27, 2022 KWIK HUS-EZ (KH-EZ) 3/8 (3 1/4) 418059 KH-EZ 3/8"x4" h.1 = 2.500 in., hnom = 3.250 in. Carbon Steel ESR-3027 4/1 /2022112/1/2023 Design Method ACI 318 / AC193 eb = 0.000 in. (no stand-off); t = 0.500 in. Page: Specifier: E-Mail: Date: Anchor plateR : 1. x IY x t = 3.000 in. x 12.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: Base material: Reinforcement: no profile cracked concrete, 4000, fc' = 4,000 psi; h = 12.000 in. tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) no R -The anchor calculation is based on a rigid anchor plate assumption. Geometry [In.] & Loading [lb, In.lb] X Input data and results must be checked for confonmity with the existing conditions and for plauslbilityl PROFIS Engineering ( c) 2003-2022 Hilti AG, FL-9494 Schaan Hilli is a registered Trademark of Hilli AG, Schaan 6 5/27/2022 I:11S.-I Hilti PROFIS Engineering 3.0.78 www.hilti.com Company: Address: Phone I Fax: Design: Fastening point: 1.1 Design results Case I Concrete -May 27, 2022 Description Combination 1 Page: Specifier: E-Mail: Date: Forces [lb)/ Moments [in.lb) N = 0; Vx = 0; Vy= 1,000; MX = 0; My= 0; M, = 16,640; Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c) 2003-2022 HilLi AG, FL-9494 Schaan Hilti is a registered Trademark of Hilli AG, Schaan 7 2 5/27/2022 Seismic Max. Util. Anchor[%] no 84 2 1 : i i S • i _____________________ _ 8 Hilti PROFIS Engineering 3.0.78 www.hilti.com Company: Page: 3 Address: Specifier: Phone I Fax: I E-Mail: Design: Concrete -May 27, 2022 Date: 5/27/2022 Fastening point: 2 Proof I Utilization (Governing Cases) Design values [lb] Utlllzatlon Loading Proof Load Capacity (3N / f3v [%] Status Tension -I -N/A Shear Concrete edge failure in direction x+ 2,308 2,749 -/ 84 OK Loading (3N f3v t Utilization f3N,v [%] Status Combined tension and shear loads N/A 3 Warnings Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c) 2003-2022 Hilti AG, FL-9494 Schaan Hlltl is a registered Trademark of Hilli AG, Schaan 3 •=iiS•• 9 Hilti PROFIS Engineering 3.0.78 www.hilti.com Company: Page: 4 Address: Specifier: Phone I Fax: E-Mail: Design: Concrete -May 27, 2022 Dale: 5/27/2022 Fastening point: 4 Remarks; Your Cooperation Duties Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc .. that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilli product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover. you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular. you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark or Hilli AG, Schaan 4 . . DATE ~1~, /1, 'L.. B\VE ENGR-...a.."/:::)_H...;._ __ _ IHGl#ElltlO TO 1•c11.o 1x,1CTATIONJ PROJECT ----i-1Z.;;;..;E:;.;:-t:.~-p-__ T:....·...::::I-==--·------- - ~ ~ ,, >'-?-<J" t=t -:=:. ~c, b l=t=-~~ t /"' c_. ~ {,o o )(: I 1.. A-c...» rJJ!) --9 ' 01-It. ). <L&~ psi.. . $ .. -s I z.. ;,/ l x 4 ::. I . , t, 1-" ~ /4. l( ~ /ft(c. ~ oc.,r_s w :::. e;-, J #- 3 .., G;"-t8 69 ¥ t; l 3 ::.. I , 5 s 9 .Jt: (t:00# ,eE-;dL +1~:::; S&t(::>C:,D '(_0.(: 10 SHEET JOB NO _____ _ ( t · 1 1, r ., ~I l 7o ~ ~-(,"<th dL ,L,~ ECS ENVIRON1\--tENTAI-,. INC. C SPECIALIZING IN I.EA.D -~1.0LD -ASBFSTOS ,v,v,v.ECS-ENVIRONMENTALSERVICES.COM May 6, 2021 Natalie Molina-Ortega Project Coordinator White Construction _ r;: \\J E. 0 2524 Gateway Road R 'E. C ,;. .... Carlsbad, California 92101 · . r. o 1U71 jJ\'{ \I 0 RE: Asbestos Testing y of cPJJ,_l SB6~ 2290 Cosmos Court, Carlsbad, California 92~J\LDING oN\S\ Mastic, Carpet/Mastic, Drywall/Joint Compound, Cove/Mastic, Duct Tape/Insulation, Ceiling Tile, Wall Sheeting/Mastic, Vinyl Sheet Flooring, Vinyl Tile, Roofing, Penetration Mastic Dear Ms. Molina-Ortega; > I-This report documents the laboratory analytical results of the Asbestos PLM sampling con du Ji I a by Michael Mize AH REA building inspector, working under the direction of Bond L. McCowanl'r-'\ CAC. The fifty-one (51) samples of mastic, carpet/mastic, drywall/joint compound, cover /malliJ duct tape/insulation, ceiling tile, wall sheeting/mastic, vinyl sheet flooring, vinyl tile, roofing, penetration mastic was collected on May 5, 2021, and submitted to EMLab P&K in San Diego, California, for processing. A total of one hundred-three (103) samples were analyzed, including all layers. The laboratory analytical results of the samples indicate l!Q.Asbestos Containing Materials (ACM) were detected. Should you have any questions after reviewing the conclusions and recommendations contained within this report, please do not hesitate to contact the undersigned at (619) 921-3121. ECS Environmental, Inc. remains available to assist you in any way possible. -1876 SANTA ~tONICA AVE. SUITE 172 --SA~ DIEGOt CA 92107 (0) 1-800-Stl-6364 (f) 480-719--t-46S \\'\Y\V.ECS-E~VIRONMENTALSERVICES.COM 1-;cs ENVIRONl\111---:N~~AL. INC. C SPECIALIZING IN LE.AD -l\fOLD -ASBESTOS vv,vvv:ECS-ENVIR()NMENT A LSERVICES.COM Sincerely, ECS Environmental, Inc. Bond L. Mccowan, Sr. California Certified Asbestos Consultant Attachments: Table 1, Laboratory Analytical Results, .,, ' \ J ;_,.,.r;.-1• Chain of Custody, Field Sketch, Inspector Certification -1876 SANTA MONICA AVE, SUITE 172 -SAN DIEGO, CA 92107 (0) 1·800·5tl·6364 (F) 480-719·4%5 W"'\i\'.ECS-ENVIRONMENTALSER\-1CES.COM TABLE 1 Asbestos Results 2290 Cosmos Court Carlsbad, California 92011 May 5, 2021 Area Tested Type of Material Sample Sample Quantity Number (s) Locations Sample Description Interior Mastic 1 2nd Floor Wall Mastic (Black) 50 Sq Ft Drywall (White) Interior Mastic 2 2nd Floor Middle Mastic (Black) Drywall (White) Mastic (Yellow) Interior Carpet/Mastic 3 2nd Floor Middle Carpet (Blue) Skim Coat (White) Plaster (Gray) Interior Carpet/Mastic 4 North Entrance Mastic (Yellow) Carpet (Blue) Interior Carpet/Mastic 5 North Office 1,500 Sq Mastic (Transparent) Ft (Brown) Interior Carpet/Mastic 6 East Office Mastic (Yellow) Carpet (Brown) Interior Carpet/Mastic 7 2nd Floor Middle Mastic (Yellow) Carpet (Brown) Interior Carpet/Mastic 8 West Office Mastic (Yellow) Carpet (Brown) ND= None Detected CH=Chrysotile CR=Crocidolit A=Amosite N/A=Not Analyzed A/P=Assume Positive *~*Contractor shall follow all OSHA regulations with samples less <1% Carpet PLM Condition Percent Results Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% 3 Area Tested Type of Material Sample Number(s) Drywall/Joint Interior 9 Compound Drywall/ Joint Interior 10 Compound Drywall/Joint Interior 11 Compound Interior Drywall/Joint 12 Compound Drywall/Joint Interior 13 Compound Interior Drywall/Joint 14 Compound Interior Drywall/Joint 15 Compound Interior Drywall/Joint Compound 16 TABLE 1 Asbestos Results 2290 Cosmos Court Carlsbad, California 920 l l May 5, 2021 Sample Quantity Locations West Office Sample Description Drywall (White) Tape (Beige) Joint Compound (White) Drywall (Pink) West Office Tape (Beige) Joint Compound (White) Drywall (White) North Entrance Tape (Beige) Joint Compound (Off-White) North Office 125,000 Drywall (White) Sq Ft Compound (White) DrywaJl (White) 2nd Floor Middle Compound (White) 2nd Floor Middle Drywall (White) Compound (White) East Office Joint Compound (White) East Office Drywall (White) Compound (White) ND= None Detected CH=Chrysotile CR=Crocidolit A=Amosite N/A=Not Analyzed A/P=Assume Positive ***Contractor shall follow all OSHA regulations with samples less <1% Condition PLM Percent Results Good ND 0% Good ND 00/o Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% 4 Area Tested Type of Material Sample Number(s) Interior Drywall/Joint 17 Compound Interior Cove/Mastic 18 Interior Cove/Mastic 19 Interior Cove/Mastic 20 Interior Cove/Mastic 21 Interior Cove/Mastic 22 Interior Duct Tape/Insulation 23 Interior Duct Tape/Insulation 24 TABLE 1 Asbestos Results 2290 Cosmos Court Carlsbad, California 9201 l May 5, 2021 Sample Quantity Sample Description Locations North Lab Drywall (White) Compound (Off-White) Baseboard (Black) 2nd Floor Middle Mastic (Yellow) Joint Compound (White) North Lah Baseboard (Black) Mastic Brn Paper (Yellow) Baseboard (Black) North Entrance 4,500 Sq Mastic (Yellow) Ft Joint Compound (White) Baseboard (Black) North Office Mastic (Yellow) Joint Compound (White) Baseboard (Black) East Office Mastic (Yellow) Joint Compound (White) North Entrance Insulation (Tan) 2,500 Sq Tap Silver Foil (Brown) North Lab Ft Insulation (Yellow) Tap Silver Foil (Brown) ND = None Detected CH=Chrysotile CR=Crocidolit A=Amosite N/ A=Not Analyzed A/P=Assume Positive "'.**Contractor shall follow all OSHA regulations with samples less <1% Condition PLM Percent Results Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% s Area Tested Type of Material Sample Number(s) Interior Ceiling Tile 25 Interior Ceiling Tile 26 Interior Ceiling Tile 27 Interior Ceiling Tile 28 Interior Ceiling Tile 29 Interior Wall Sheeting/Mastic 30 Interior Wall Sheeting/Mastic 31 Interior Flooring Sheet Vinyl 32 Interior Flooring Sheet Vinyl 33 TABLE 1 Asbestos Results 2290 Cosmos Court Carlsbad, California 92011 May 5, 2021 Sample Quantity Locations 2nd Floor Middle East Office North Entnmce 30,000 Sq Ft North Office Server Room Sample Description Ceiling Tile (Gray) Ceiling Tile (Gray) Ceiling Tile (Gray) Ceiling Tile (Gray) Drywal1 (White) Drywall (White) Shower Joint Compound (White) 250 Sq Ft Mastic (Brown) Shower Sem-Fibrous Material (White) Mastic (Brown) Shower Sheet Flooring (Gray) 150 Sq Ft Shower Sheet Flooring (Gray) ND= None Detected CH=Chrysotile CR=Crocidolit A=Amosite N/A=NotAnalyzed A/P=Assume Positive * "'*Contractor shall follow all OSHA regulations with samples less <1% Condition PLM Percent Results Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% 6 Area Tested Type of Material Sample Number (s) Interior Vinyl Tile 34 Interior Vinyl Tile 35 Interior Vinyl Tile 36 Interior Vinyl Tile 37 Interior Vinyl Tile 38 Interior Vinyl Tile 39 Interior Vinyl Tile 40 Interior Vinyl Tile 41 TABLE 1 Asbestos Results 2290 Cosmos Court Carlsbad, California 92011 May 5, 2021 Sample Quantity Locations Mechanical Room East Store Room East North Entrance Sample Description Floor Tile (White) Mastic (Black) Floor Tile (White) Mastic (Black) Floor Tile (White) Mastic (Yellow) Leveling Compound (Gray) Shower Hall Floor Tile (White) Mastic (Yell ow) 13,500 Sq Floor Tile (Light Gray) North Office Ft Mastic (Black/Yellow) North Lab Floor Tile (Light Gray) Mastic (Black/Yellow) 2nd Floor Break Floor Tile (Light Gray) Area Mastic (Yell ow) Leveling Compound (Gray) 3rd Floor Break Floor Tile (Light Gray) Area Mastic ( Yellow) Leveling Compound (Gray) ND= None Detected CH=Chrysotile CR=Crocidolit A=Amosite N/A=Not Analyzed A/P=Assume Positive • **Contractor shall follow all OSHA regulations with samples less <1 % Condition PLM Percent Results Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% 7 Area Tested Type of Material Sample Number(s) Exterior Roofing 42 Exterior Roofing 43 Exterior Roofing 44 Exterior Roofing 45 Exterior Penetration Mastic 46 Exterior Penetration Mastic 47 Exterior Penetration Mastic 48 Exterior Penetration Mastic 49 Exterior Penetration Mastic 50 TABLE l Asbestos Results 2290 Cosmos Court Carlsbad, California 9201 l May 5, 2021 Sample Quantity Locations Sample Description Semi-Fibrous Material (White) North Middle Tar (Black) 35,000 Sq Felt (Black) Ft Semi-Fibrous Material (White) North Middle Tar(Black) Felt (Black) North Middle Tar (Black) 500 Sq Ft North Middle Tar (Black) North Middle Mastic (Dark Gray) Mastic (White) North Middle Mastic (Dark Gray) Mastic (White) North Middle 1,000 Sq Mastic (Light Gray) North Middle Ft Mastic (Light Gray) North Middle Mastic (White) ND = None Detected CH=Chrysotile CR=Crocidolit A=Amosite N/ A=Not Analyzed A/P=Assume Positive "'**Contractor shall follow all OSHA regulations with samples less <1% Condition PLM Percent Results Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 00/o Good ND 0% Good ND 0% Good ND 0% Good ND 0% 8 TABLE 1 Asbestos Results 2290 Cosmos Court Carlsbad, California 92011 May 5, 2021 Area Tested Type of Material Sample Sample Quantity Sample Description Number (s) Locations Exterior Penetration Mastic 51 North Middle ND= None Detected CH=Chrysotile CR=Crocidolit A=Amosite N/A=Not Analyzed A/P=Assume Positive ***Contractor shall follow all OSHA regulations with samples less <1% Mastic (White) Condition PLM Percent Results Good ND 0% 9 ~~ eurofins EMLab P&f\ Report for: Bond Mccowan ECS Environmental, Inc.: CA 4876 Santa Monica Ave #172 San Diego, CA 92107-2811 Regarding: Approved by: Project: 2290 Cosmos Court EML ID: 2635089 1~7/ Approved Signatory Balu Krishnan Dates of Analysis: Asbestos PLM: 05-07-2021 Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267) NVLAP Lab Code 200844-0 All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy, Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested. Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor. Eurofins EPK Built Environment Testing, LLC EMLab ID: 2635089, Page 1 of 14 Client: ECS Environmental, Inc.: CA C/0: Bond Mccowan Re: 2290 Cosmos Court ASBESTOS PLM REPORT Location: l, Back Hockey Puck Mastic Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.emlab.com Date of Sampling: 05-05-2021 Date of Receipt: 05-06-2021 Date of Report: 05-07-2021 Total Samples Submitted: Total Samples Analyzed: Total Samples with Layer Asbestos Content> I%: 51 51 0 Lab ID-Vcrs1-0nr 12583588-1 Sample Composite Homoeeneity: I Good Location: 2, Back Hocke,· Puck Mastic . Lab ID Vm1ont, 1258J5~9-I --~ampl~ayers_ ---Asbestos Contenf ---· -----. -------··----·-- Black Mastic ND i---------------------·--~-------·-----~------ White Drywall with Brown Paper Composite Non-Asbestos Content: 11 0% Cellulose Sample Comoosite Homo2eneit)·: i Good Location: 3, Carpet/Mastic Composite Non-Asbestos Content: :60% Synthetic Fibers Sample Comoosite Homo2eneity: iGood Location: 4. Carpet/Mastic Sample Layers Yellow Mastic Blue Ca et 80% S nthctic Fibers ND Lab JI). Version~: I 25K3590-I Lab JD-Versmn!: 125835'11-I Asbestos Content ND ND The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim procluct certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose ot all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is pcrfonncd. floor tile samples may conlain large amounts of interference material and it is recmnmended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification, t A "Version" indicated by -"x" after the Lab JD# with a value greater than I indicates a sample with amended data. The revision number is reflected by the value of"x''. Eurofins EPK Built Environment Testing, LLC EMLab lD: 2635089, Page 2 of 14 Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.ernlab.com Client ECS Environmental, lnc.: CA C/0: Bond McCowan Re: 2290 Cosmos Court ASBESTOS PLM REPORT Location: 5, Carpet/Mastic ~ --__ __ Sam~ Layers_ --··---- Date of Sampling: 05-05-2021 Date of Receipt: 05-06-2021 Date of Report: 05-07-2021 Lab ID-Vc-rsiont: 12583592-1 I Asbestos Content l---------------·--ND ~ -----Tra~arent Mastic __ ~ --i-------.,-~-----------~--Brown Carpet ND Composite Non-Asbestos Content: I 80% Synthetic Fibers Sample Composite Homo2eneih': ! Good Location: 6, Carpet/Mastic Lab ID-Version!: l 258J593-1 _§~le Layers I Asbestos Content --··--·-----.... _ -____ L -------------Yellow Mastic +----ND ---------------------------Brown Carpet ND Composite Non-Asbestos Content:: 80% Synthetic Fibers Sample Composite Homoeenelty: !Good Location: 7, Carpet/Mastic Lab IO-Ver.<iont: I 258J594-1 _ Sample Layers ___J ---Asbestos Content ---· --------------------,---~· ------ Yellow Mastic ND ---------~--------~•-------,--------------------- Brown Carpet ; ND Composite Non•Asbestos Content: 180% Synthetic Fibers Samnle Composite Homo2eneity: I Good Location: 8, Carpet/Mastic Lab ID-Version:: 12583595-\ _!ampl~1:'.ayers ' Asbestos Content -------•--··-·--------' -T,L-------------·----Y cllow Mastic ND -,--~~------· ------~----7------··----~"··------------ Brown Carpet ND Composite Non-Asbestos Content:; 80% Synthetic Fibers Sample Composite Homo2eneity: i Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client t0 claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EM Lab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected. the minimum detection and reporting limit is less than 1 %, unless point counting is pcrfonncd. FlooT tile samples may contain large amounts of interference material an<l it is recommended that the ~ample be analyz.ed by gravimetric point count nnalysi~ to lower the detection limit and to aid in asbestos identification. ~ A "Version" indicated by -"x" after the Lab ID# with a value greater than l indicates a sample with amended data. The revision number is reflected by the value of "x". - - Eurofins EPK Built Environment Testing. LLC EMLab ID: 2635089, Page 3 of 14 Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: ECS Environmental, Inc.: CA C/O: Bond Mccowan Re: 2290 Cosmos Court Date of Sampling: 05-05-2021 Date of Receipt: 05-06-2021 Date of Report: 05-07-2021 ASBESTOS PLM REPORT Location: 9, Drywall/Joint Compound Lab lD-Vmion!: 125835%-1 : _ _ ·--___ _ Sam.l!! Layers ____ -· _ -· ··-_ _ _ Asbestos Content__ _ __ _ _ _ __ _ WhiteD~a~ithBrownPaper ·-·---i--__ ~---_ ND_·---·--__ _ Beige Tape ND --White Joint Comoound with Tan.Pain·, I -----ND ---·~~ --- Composite Non-Asbestos Content: i20% Cellulose Sample Composite Homoi::eneity: !Good Location: IO, Drywall/Joint Compound . Lab ID-V crsion!: 1251\3597-1 Sample Laye.!!_ ! Asbeslos Content ···----· ----· -------------·- ----__fink Dl)'.!'.'.!111 with Brown P~r_ ND -·-·-· -~ ·--•---~--··-. --------- --· ---~c~T~ ND ----·----r--·-----------· -·· ------- White Joint Compound with Tan Paint i ND Composite Non-Asbestos Content: '20% Cellulose Sample Composite Homo2eneitv: : Good Location: 11, Drywall/Joint Compound Lab ID-Version!: 1258.,598-1 Asbestos Content --··-__ ~1!1~ Laye~ __ --·-I -------------- \Vhite D~all with Brown Paper _ ND ------------------· ---- ND -----___ Beig~~p~ _______ ---·--· ·---··~-·----------------·· -----·- White Joint Compound with Off-White Paint ND Composite Non-Asbestos Content:! 20% Cellulose Sample Composite Homo2eneity: 'Good Location: 12, Drywall/Joint Compound Lab ID-Vcr,ion!: 1258]599-I -Saml!!! Layer_!_ Asbestos Content ~ -------·· ----~ -·---------·-·--- White Drywall with Brown Pap~ __ ND ,_ -------1---··-·----·---·-----" ----- White Joinl Comoound with Tan Paint i ND Composite Non-Asbestos Content:: 10% Cellulose Sample Composite Homo2eneitv:; Good The test report shall not be reproduced except in full, without written approval ofth1; laboratory. The report must not be used by the clien1 10 claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days. according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1'% unlc~s point counting is perfonned. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analy1.ed by gravimetric poinl count analysis to lower the detection limit and 10 aid in asbestos identification. t A "Ver~ion" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". -- Eurofins EPK Built Environment Testing, LLC EMLab ID: 2635089, Page 4 of 14 Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: ECS Environmental, Inc.: CA C/0: Bond Mccowan Re: 2290 Cosmos Court Date of Sampling: 05-05-2021 Date of Receipt: 05-06-2021 Date of Report: 05-07-2021 ASBESTOS PLM REPORT Location: 13, Drywall/Joint Compound Lab ID-Version~: 12583600-1 __ Samp)! L~ers Asbestos Content ------------· --------------White DrywaH with Brown Paper ND ~-----~--------------------- White Joint Compound with Black Paint I ND Composite Non-Asbestos Content: I 10% Cellulose Sample Composite Homoeeneln·: ! Good Location: 14, Drywall/Joint Compound Lab ID-Vcr,;ion!: )2583601-1 Sam~ Laye!!.__ ~ ----------~--1-------- _ White Drywall with Brown Pa2er __ --t ------------ White Joint Compound with Black Paint Composite Non-Asbestos Content: i l0% Cellulose Sample Composite Homol!:eneity: I Good Location: 15, Drywall/Joint Compound Sample Composite Homol!:eneity: i Good Asbestos Content -·------· ----ND ------ND Asbestos Content ND ---- - - Location: 16, Drywall/Joint Compound Lab ID-Version! 1258}1,0J-l Same!! Layer_!___ Asbestos Content ----·-~ ----~ --• ------~ --------~ ND -----___ While Drywall with Brown Paper __ --f-------------~ --------- White Joint Compound with Tan Paint ND Composite Non~Asbestos Content: 10% Cellulose Sample Composite Homo~enelt)·: Good The test report sh1dl not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days. according to all state and federal ~ruidclincs, unle1.,s otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected_ When detected, the minimum detection and reporting limit is less than I%, unless point counting is performed, Floor tile samples may contain large amounts of interference material and it is recommended th31 the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. t A "Version" indicated by-"x" after the Lab ID# with a value greaterthan I indicates a sample with amended data. The revision number is reflected by the value of "x". Euroiins EPK Built Environment Testing. LLC EMLab ID: 2635089, Page 5 of 14 Client: ECS Environmental, Inc.: CA C/O: Bond McCowan Re: 2290 Cosmos Court ASBESTOS PLM REPORT Location: 17, Drywall/Joint Compound Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.emlab.com Date of Sampling: 05-05-2021 Date of Receipt: 05-06-2021 Date of Report: 05-07•202 I Lab ID-Vcrsiont: 1258."\604-l Sample Layers Asbestos Content = White~i~~=:~:i~i~:~1:-::7ePai: =--7----~---~----_ --:~ ~--= Composite Non-Asbestos Content: 1· I 0% Cellulose 3% Glass Fibers Sample Composite Homoe:eneitv: /Good Location: 18, Cove/Mastic _ _ __ _ Sample Layers _ _ __ Black Baseboard Yellow Mastic Lab ID-Vcrsiout: !2583605-1 Asbestos Content -~•-- ND ND ·----------- ND eneitv: Good Location: 19, Cove/Mastic Lab ID-Version!: 115~3606-1 __ _ _ Sam~_tayers _ 1 Asbestos Content Black Baseboard -r----------··--· -+-__ __ __ _ ____ ND _ _ _, Yellow Mastic /Brown Paper Backinl! Composite Non-Asbestos Content: I 10% Cellulose Sample Cornnosite Homoeeneih·: [Good Location: 20, Cove/Mastic ___ Sample Layen Black Baseboard Yellow Mastic ······-·--·------White Joint Compound 1 Sample Composite Homoeeneih': I Good ND Lab ID-\'.,,-i;ionr 1~5!0607-1 Asbestos Content -,_ -----· ND ND ND The test report shall nol be reproduced except in foll, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any a~wncy of the federal government. Eurofins EM Lab .P&K reserves the right 10 dispose of all samples after a period of thirty (30) days. according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reponing limit is less than 1% unless point councing is pcrfonncd. Floor tile samples may contain large amounts of interference material and it is recommended chat the sample be analyzed by gravimetric point coun1 analysis to lower the detection limit and to aid in asbestos identification, t A "Version" indicated by •"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of"x". Eurofins EPK Built Environment Tescing, LLC EMLab ID: 2635089, Page h of 14 Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: ECS Environmental, Inc.: CA C/O: Bond Mccowan Re: 2290 Cosmos Court Date of Sampling: 05-05-2021 Date of Receipt: 05-06-2021 Date of Report: 05-07-2021 ASBESTOS PLM REPORT Location: 21, Cove/Mastic Lab ID-Vcrsiont: 12583608-1 -· _____ Sample La,·ers . __ -------~1-_______ Asbestos_Contenl __ Brown Baseboard I ND ~--_-_-_-_Yellow Mastic=---=-----_l ________ ND _____ _ White Joint Compound I ND Sample Composite Homogeneity: i Good Location: 22, Cove/Mastic Lab ID-Version:;: I 2583t>09-l Yellow Mastic . __J_ White Joint Compound ' Sample Composite Homo2.eneih·: i Good Location: 23, Duct Tape/Insulation . Sam~Laye~ -t ~ •-------------· Tan Insulation --- ND ND Lab ID-Version!: 12583610-1 Asbestos Contenl ---------· ND ·------·--------------~~ ------------- Brown Tape /Silver Foil I ND Composite Non-Asbestos Content: 160% Mineral Wool 20% Cellulose Sample Composite Homogeneity: : Good Location: 24, Duct Tape/Insulation Lab ID-\'~rsmn{.12510(,11-1 ~"!}lie Layer_~_ I Asbestos Content -·-~-------------------·--~-------·· --- Yellow Insulation ND ~----~ -· --------~ ---------_J -----· ----------------- Brown Tape /Silver Foil I ND Composite Non-Asbestos Content: I 60% Mineral Wool 20% Cellulose Sample Composite Homogeneity: 1Good The test report shall not be reproduced ex.cept in full, without written approval of the laboratory. The report must not be used by the client to claim producl certification, approval. or endorsement by any agency of the federal government. Eurofms EM Lab P&K reserves the rig.ht to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines. unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. I\D means no fibers were detected. When detected, the minimum detection and reporting limit is less than I% unless point counting is pcrfonned. floor tile samples may contain large amounts of interference material and it is recommended that the samrlc be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. t A "Version" indicated by -"x" after the Lab ID# with a value greater than I indicates a sample with amended data. The revision number is reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC EMLab ID: 2635089, Page 7 of 14 Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: ECS Environmental, Inc.: CA C/O: Bond McCowan Re: 2290 Cosmos Court ASBESTOS PLM REPORT Date of Sampling: 05-05-202 I Date of Receipt: 05-06-202 I Date of Report: 05-07-202 I Location: 25, Ceiling Tile Lab !D-Versiont: l25~3612-1 Asbestos Content ---______ Sample Layers ______ -+----· --· ----------- Gray Ceiling Tile with White Surface ND Composite Non-Asbestos Content: 160% Cellulose , 15% Mineral Wool Sample Composite Homoj!eneitv: !Good Location: 26, Ceiling Tile Lab ID-Ycrsioni. 125~3nl'l-l -----___ ~a!!!ele Layers ________ I _ Asbestos Content ---------------- Grav Ceiling Tile with White Surface i ND Composite :'.'ion-Asbestos Content: !60% Cellulose 15% Mineral Wool Sample Composite HomogeneitJ: 1Good Location: 27, Ceiling Tile Lab ID-Vcrsiont: 12:iRJt,14-1 Asbestos Content ---___ Sample Layers _ _ _ __ _J -------------~ ~ ----- Gray Ceiling Tile with \Vhite Surface ND Composite Non-Asbestos Content: 160% Cellulose 115% Mineral Wool Sample Composite Homogeneity: I Good Location: 28, Ceiling Tile Lab 10-Vcrsiont. I 2.IR36 I '-I ---~mple Layers -~~-_ t-Asbestos Content ----------· ·--·-~-------------- Gray Ceiling Tile with White Surface ND Composite Non-Asbestos Content: j 60% Cellulose 1 15% Mineral Wool Sample Composite Homo~enein·: I Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must nor be used by the client to claim product certification, approval. or endorsement by any agency of the tedcral government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsampks and analyzed individually. I\D means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is perfonncd. Floor tile samples may contain large amounts of interference material and ii is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in a.~bestos identification. t A "Version" indicated by -"x" after the Lab ID# with a value greater than I indicates a ~ample with amended data. The revision number i~ reflected by the value of"x". - Eurotins EPK Built Environment Testing, LLC EMLab ID: 26350K9, Page K of 14 Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: ECS Environmental, Inc.: CA C/O: Bond Mccowan Re: 2290 Cosmos Court Date of Sampling: 05-05-2021 Date of Receipt: 05-06-2021 Date of Report: 05-07-2021 ASBESTOS PLM REPORT Location: 29, Ceiling Tile Lab ID•Version;: \25836U,-1 ~ample _Layers ··-+-Asbestos Content ------------······----------~ White Drywall with Brown Paper I ND Composite Non-Asbestos Content: i 10% Cellulose Sample Comnosite Homogeneity: I Good Location: 30, Wall Sheeting/Mastic Lab ID-Version!: 12583617-1 ____ _ _______ Samp)eLayers _____ --_·--+_ I ___ _ __ --_--AsbestoNsOContent _____________ _ ___ ·-·· __ White D~all with Brownyaper _ _ l _ _ __ _ _ White Joint Compound_ __ _ --+--_____ _ ND Brown Mastic ND Composite Non-Asbestos Content: 110% Cellulose Sample Composite Homo2eneitJ·: !Good Location: 31, Wall Sheeting/Mastic Lah lD-Vcr,,ion!: 1258361 ~-1 _ Sam~ La_1crs -~ __ I Asbestos Content ---·--·-·--·-+---·-·----- White Semi-Fibrous Material ND --·-·---------------------·-·-----·----------Brown Mastic I ND Composite Non-Asbestos Content: i20% Glass Fibers Sample Composite Homo2eneity: !Good Location: 32, Flooring, Vinyl Sheet Lab ID-Versmnt: 12583619-l Asbestos Content ____ ···-Sample Layers _ _ _ _ Gray Sheet Flooring with Fibrous Backing --· --------·----ND Sample Composite Homogeneih': 1 Good The test report shall not be reproduced cxcep1 i11 full, without wrillen approval of the laboratory. The report mus! not be used by the client to claim product ccrtificntion, approval. or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all stale and federal !,,'llidclines, unless otherwise specified. Inhomogeneous sampics are separated into homoge11eous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than I% unless point counting is perfonncd. Floor rite samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. t A "Version" indicated by _Nx" after the Lab ID# with a value greater than I indicates a sample with amended data. The revision number i, reflected by the value of"x". Eurotins EPK Built Environment Testing, LLC EMLab JD: 2635089, Page 9 of 14 Eurotins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: ECS Environmental, lnc.: CA C/O: Bond McCowan Date of Sampling: 05-05-2021 Date of Receipt: 05-06-2021 Re: 2290 Cosmos Court Date of Report: 05-07-2021 ASBESTOS PLM REPORT Location: 33, Flooring, Vinyl Sheet _ ... ____ Sample Layers_ -· ___ __ _ __ Gray Sheet Flooring with Fibrous Backin.11: Samnle Comoosite Homo2eneity: i Good Location: 34, Vinyl Tile Black Mastic i Sample Composite Homo2eneitv: iGood Location: 35, Vinyl Tile -·--- Sample La~_ White Floor Tile Black Mastic +--------- Location: 36, Vinyl Tile __ ~ _ _ __ Sample Layers_ White Floor Tile Yellow Mastic ··7 ·-· -- -----I- Sample Composite Homo2eneltv: '.Good Lab rD-Versiont: 12583620-1 Asbestos Content ---- ND Lab ID-Vcr~ion;: !~51!3621-1 Asbestos Content ND ND Lub ID-Vcr.iion!: l 251!3622-1 Asbestos Content -~-- ND ND Lab ID-Vcr,ion~: 1~58362.1-1 Asbestos Content -·---·------~ ND ND ND The tcM report shall not be reproduced except in full, without written approval of the labomt0ry. The report must not be used by the client to daim product certificatim1, approval, or endorsement by any agency of the federal government Eurotins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and fedcrul guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually, ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than I% unless point counting i~ performed, Floor tile ~m1ples may con lain large amounts of mterfercnce material and it is recommended that the sample be analy7.ed by gravimetric point count analy~is to lower the detection limit and to aid in asbestos identification. t A "Version" indicated by -"x" after the Lab ID# with a value greater than l indicates a sample with amended data. The revision number is rellectcd by the value of"x". Eurofins EPK Built Env1romnent Testing, LLC EM Lab JD: 26350!<9, Page 10 c>f l4 Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: ECS Environmental, Inc.: CA C/0: Bond McCowan Date of Sampling: 05-05-2021 Date of Receipt: 05-06-2021 Re: 2290 Cosmos Court Date of Report: 05-07-2021 ASBESTOS PLM REPORT Location: 37, Vinyl Tile Sample Composite Homo2enelh': !Good Location: 38, Vinyl Tile __ ---· __ ~-Sample Layers _______ ~- ~ -~ ~Light Grnr.!:!.oor Til_e ~ ___ ~ Black/Yellow Mastic Sample Composite Homoe:eneit•,: 1 Good Location: 39, Vinyl Tile _ Same!_('__Layers I f---_ Light Gray Floor Ti~_ _ _ _ __ ~ _ Black/Yellow Mastic : Sample Composite Romo11.eneitv: [ Good Location: 40, Vinyl Tile _ Sam~Layers ___ _ I ~ Light Gray Floor Tile __ Y cllow Mastic -------- Gray Levelin~ Compound 1 Sample Composite Homoeeneit,,: !Good Lab IO-Versiont: 12583624-1 Lab TD-Vc>1<ion~: 12583625-! Asbestos Content ~-------------- ND ND I.ab ID-Version;: 1258.\626-l Asbestos Content ND ND Lab ID-Versiont 125HJ6:'7-1 Asbestos Content ND TI1c test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines. unless otherwise specified. Inhomogeneous samples arc separated into homogeneous subsampl~ and analyzed individually. ND means no tibers were detected. When detected, the minimum detection and reporting I imit is less than I% unless point counting is pcrfonncd. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analy7.ed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. ; A "Version" indicateil by -"x'' after the Lab 10# with a value greater than I indicates a sample with amended data. The revision number is reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC EMLab ID: 2635089, Page 11 of 14 Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: ECS Environmental, Inc.: CA C/0: Bond Mccowan Re: 2290 Cosmos Court Date of Sampling: 05-05-2021 Date of Receipt: 05-06-2021 Date of Report: 05-07-2021 ASBESTOS PLM REPORT Location: 41, Vinyl Tile Lab ID-Version!: 12583628-1 _ _ _ ____§_itmple Layers _ _ Light Gray Floor Tile Yellow Mastic I Sample Composite Homo2enelty: iGood Asbestos Content --------------- ND ND -~----, ---- ND Location:42,Roofing ub ID-Vcrs,on;: 12583629-1 _ __§ample Layers l Asbestos Content ----------=-=--~_T_ ------------------- -----White Semi-Fibrous Material ND -··· -------~------------------- Black Tar I ND ----------------------------·-·--------Black Felt ND Composite Non-Asbestos Content: I 30% Glass Fibers Samnle Comnosite Romoeeneity: i Good Location: 43, Roofing Lab ID-Version; 1251\3630-1 __ ,..____ _ Sample Layers -·- White Semi-Fibrous Material -------------·--Black Tar ! ----I --Asbestos Content ND ND ----------·-----·---------Black Felt ND Composite NonMAsbestos Content: i 30% Glass Fibers Sample Composite Homo2enelty: , Good Location: 44, Roof Patch LablD-Vmion;: 125R_1631-I ~ -. -Sample Layers ____ Asbestos Content ---------------·· l ---~ -----------··-. ---·-··· Black Tar ND Composite '.'Ion-Asbestos Content: 15% Cellulose Sa mole Comoosite Homo2eneih·: , Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than l % unless point counting is perfonned. Floor tik samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid 111 asbestos identification. t /\ "Version" indicated t,y-"x" after the Lab ID# with a value greater than I indicates a sample with amended data. The revision number 1s reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC EM Lab ID: 2635089. P~gc-12 of l 4 Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www .emlab.com Client: ECS Environmental, Inc.: CA C/0: Bond McCowan Date of Sampling: 05-05-2021 Date of Receipt: 05-06-2021 Re: 2290 Cosmos Court Date of Report: 05-07-2021 ASBESTOS PLM REPORT Location: 45, Roof Patch -----~-Sample Layers Black Tar ----~~f~-- Composite Non-Asbestos Content: I 5% Cellulose Sample Composite Homo2eneity: i Good Location: 46, D Grey Penetration Mastic Sample Composite Homoeeneih·: I Good Location: 47, D Grey Penetration Mastic Lab ID-Versiont: 12511,3632-1 Asbestos Content ~~ ~-----~- ND Lab ID-Version!: 12583633-1 Lab ID-Vmio~t: !2583634-1 Asbestos Content ---~--~---~ ND _ -~ __ Sample L~rs_ _ __ --, _ _____ DarkGrayMa~tic~-~ __ ~ White Mastic -~~~-~ ~· -- Sample Composite Homoeeneity: Good Location: 48, L Grey Penetration Mastic _ ~-Sample Layers __ Light Grav Mastic I Sample Composite Homoeeneltv: : Good ND Lub ID-Version; I 25~36J5-I Asbestos Content ND The tesf report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the clienl lo claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EM Lab P&K rcsen,cs the right 10 disrose of all samples after a period of thirty (30) days. according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is perfonncd. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. t A "Version" indicated by -"x" after the Lab ID# with a value greater than I indicates a sample with amended data. The revision number is rctlecied by the value of "x". Eurofins EPK Built Environment Testing. LLC EM Lab ID: 2635089, Page 13 of 14 Eurofins EMLab P&K 3000 Lincoln Drive East, Suite A, Marlton, NJ 08053 (866) 871-1984 Fax (856) 334-1040 www.emlab.com Client: ECS Environmental, Inc.: CA C/O: Bond McCowan Re: 2290 Cosmos Court ASBESTOS PLM REPORT Location: 49, L Grey Penetration Mastic Sample Lavers Light Grav Mastic Sample Composite Homoe.eneity: Location: 50, White Penetration Mastic Sample Layers White Mastic Sample Composite Homoe.eneitv: Location: 51 , White Penetration Mastic Sample Layers White Mastic Sample Composite Homoeeneitv: Date of SampHng: 05-05-202 I Date of Receipt: 05-06-2021 Date of Report: 05-07-2021 Lab ID-Versiont: 12583636-1 Asbestos Content ND Good Lab ID-Version.t: 125 3637-1 Asbestos Content ND Good Lab ID-Vcrsiont : 12583638-1 Asbestos Content ND Good The test report ha.II not be reproduced except in full, without written approval of the laboratory. The report must not be u ed by the client to claim product certification, approval , or endorsement by any agency of the federal govemment. Eurofins EML11b P&K reserve the right to dispo c of all amples after a period of thirty (30) days, according to all state and federal guidelines, unle ·s otherwi c specified. Inhomogeneous samples nre separated into homogeneous ubsample and analyzed individually. D means no fibers were detected. When detected, the minimum detection and reponing limit is less than I% unless poi at counting is performed. Floor tile samples may coninin large amounts of imcrfercnce material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. t A "Version" indicated by -"x" after the Lab JD# with a value greater than J indicales a sample with amended data. The revision number is reflected by the value of ''x". Eurofins PK Built nvironment Testing, LLC MLab ID: 2635089, Page )4 of 14 CH/\IN or CUSl O[)Y ~ ·. l'LUOfiu -. . WI /1111• I< I ,, 1, ~" .. ~ ,'. I t·,.tt v,,,Nw I.Ml 11tPK l.111 11 •i11li u1.N.I t,11t,.1 t 1.11,,1•1' lt• ,\ M.1•h11J J J;Jiu• ·~ •,Jkih)l,;]1.1 .8 F"'h n 11.. A..l.. 1~_1!.:I ~-v .. l ~" :J•t l"I .1t l 'li1.-1fh /\,':111 I./ • (80 }651....f..802 r-.-•• ' I ~l''' ) JJ ~ w ~·h•d "'--t', ' I lt'!,l-. , ---'SiS.r, CA 11)' -..l •a, '•"IP' .,le• ;11 •• '•·" I ,lf'ht·~. I;\ 1.1, ,1., I' (llti6) tl6S i.t.. ~ 1,111 ·• ► '' .,,. > ,. 11 1 ii 1· ' • 111•1 ,t,,_,,.,1 •\;,1 I 0 l' {._ v ~ C ~ o.; ' I.. Cl7 L' ,t: tr.,) I I 1! \J 6C:> C,.,v, .,,~~w ,3<.,-,d ,v1c ~ ....... ,, I,·, l, ,,. l. • \. ,~ '/ IJ + i ..... f-1 ) J, . J v.,1,.-..Pi .... ,, I! 1·u-'l 1,iu ,,1,{IJ.i,1 ,t. S Pl L: rYP • COO S CONlA(' i llt~O rt Tl N flJRt>IAROUN Tl ~HJ ., , ,d 11·1 , .... f ,1 I NII I· t •' IJ ,/Ii ••• I I\ ,, )'-' ( I,,·••• ,t•. f I I' ~, , )' ()I) ',L { "l '}, r i I I •J ll1. "~ '• ,, , , •• • ,I f!, 1 ... 111 l,•1 ., .. 'I,•·· • , ,1 \'.I I ( t• .1•11 Ii ,, I 1, 'I•.,. 41' ,, t, I. f<. l I' I •' JI ,I ... 1•, ,, '' --~--'-.....::___J=. l>ATE; & 1 lr.11:: I 1 t;nr1-l.,,hl.li,d.1t" I,, ·• I • , I ,I 11~ J• t, tto" f , II•.' 1, tl·t• h•••• • ii-·l I l f lltl•: II , .t:I •1,Jll1 .,I 'U I •.~··.:.,,,_ 1,1 ,_, ,,t 11 lh, I ·dl''iP JI L11 _1.111 .tdlf1•. , • .,1 ~th l~l-'.t .. ' I! II IHl:111 11 H 111 JI 111 1 1 ♦1 I., ',',f\ I I., ' . .. ,, ~ I ,. ~ ~ ,. " , . •. ~ It , ~ = I > r. V- t1 ' = ''- ... N t" N • ::- . C /) ~ r., ~ f - !' !1 :, , .. . I, r V. .. . . , ~ _, :.. ::, , .- 't! ' ~ -: f _, k ~ . ~ -, .. ~ 5 .; -< I -c ; . = - .. ... ,> ;. ,. ~ ~ ~ ;. - ., . _ - - ' =- ~ . :: . ' I - I 0 -~l 1 r' . ~I ~ -~ ~ ,. J ~- ~ J f .. .. . "· ;. ... - 1= ;; ~ - -- ~ ~ I - I ~' .. "-t\ :i: ; I . ,. . )) ~r ._ - ;: : I -< ~ ; l ; .,. "- ; 1~ -= ,-- f -" ·; p r. J · I -0 :! -: . -; C/l ::, , ,,. t :l: = .. . J ~ I I 1- : ~ ,~ l 11 ,l - ~ ~ ? .J ) .. ( .. . . !: 1" ' ~ :. . ' I ::: , ... , c.~ Il l ~ ' ~ 'c r,J ; ) ,. . . ... ~ ~ 1" b LS ::: ; J !. I :: - "' C: ~' ~- re :i: ; - I ~I - I :1 '= iiE - :i I 0 ,-:r .. -· , fl \ C" ' ; I I ., ~ • l ~ .. .. ;. . .-z -;. ~ ~ !" · ~~ ; ., : ... E I: . ... . . :. : - I i- - : ~ ".: -. = = -- - - .- -- - ~ ... . . . :i < > 7 z C -.:. . ;:: (j C - 'l , .. . . . ,- . . :J -< • . • I I ~ ,.. . ~ ., ·d I CHAIN or c us rorw w~w, t.:Ml .1hf'K1..,111 , · ('urofins REOU[SHO Sl:-RVICl'S ---7 ll Hh1 tJ,,_.•.(.;UflLir J.h~, M.11tr<111. tU t.1!1:I a·u 1.11 r~-I r ,,. ,\ F-..t,p\la.'11 ~.,J H~~l1.'1 t iRhft) R71 -1«19,4 Phn-Atil..-, Iv I',:!) VV1••.1 k.11 i1~w• ll,1-.,t-· li1-1•11 1t( ,\/ :.;•:1.1/ • r800t b!-t4SOi ~•-~f C A ,., •. ;1 •;1:1 q (11,11 .,, .. ·,1r, ', l,,nJ 1.111 .ll,,1•• ,.[, 1'-lflr{ .. , ~,etiC.>HiHA-hr~!t1 r ....... •.•·.~ J.!_:~•-'"'·'"' ... .,, . ,,.,.,,,~~· ij·'""' I ;;ltjlff;I'•· I _l!~r,~ ... ·------•---~·,·,, ti•· 'l.., ft• Pnll /th1i" I "-,,u,f \\ J\ :. wrt\l'\F\'t::\\ ~'\1'\ r 1 r:om I\C1 INrORMIITIO~~ ·,i,.,·, .. ,.,...,.., ..... ,"' ,--L.. w /•,·1f1 , (' ~ ~-. .... 1'7c,.,, +1..11 . ..,,,. (::C :.> ,3r ..... , 1 'P"•1·,l l111,'1 )(:11111 /]l_ 5,,( 4 uu1 ,,1•1-• c •~,, ....... ,~,, .. -~l°i ·'1 t-,,.';' 1,,1,-.1 I •• ., I ,h '111 I 11 111 •·111 "AMP!!' 10 ~1.. 3 ~-1 3 "'3; g, 3'-'i (..j ..) L lt 3 ' ( Z 7 'i ...,."......., ,, •,,1:111.!1o,. .~:"! · .. 1, •\~, C~~· ~,<" / l,}p, ,, ,:,A..,/ ··1=· Ill SCRIPTIO <-...>.t' .. ~\....u l. t.,.,.,-,-r ...... If. J, L-(t + '"/ {: l J, t) \~ .~,-\..( -:J, --~---~---------==----=-==--•--- ) i I \ I \ !!IHI; ARDUNO !IMC. C:OOCS -(l l\11 SlD I \t 1n,.~1 u, r-1 , ,. ·,, ,..1.-,,,1 .,!·, .. ✓11 I 1• I ,• ,•1•l t~'.lo(j '• I~ f • ND N, •I H 1•.1'1, •, I• 1v ,,.,.,,,', fl•d It i\•t•· ·t-1• '10 ,'Ill!' hO-,tlH' ,•;!1,1-1 111 •I '.ti 1-,1f11"!1,•, 11.-t)' ,.,, ,t· I ,I ,u 111•, 1n .111~•,jl I ,. I ,t ..,.,. •. ,.~ , .. 1;1 .·111.,t·.-· .. WH \·\'t:1?•t 1t·I t.1 ,·l•'.;.,\11 ~-101.,1 ~ 'Vol11tru~ll\1 ~., (Ti1nr o l rfJv ~.l"l 1,pp:11., ... ,,,1,., -s~,ri .... <,...,1.,:\ l Ui fp1rip lUt oA1r..\ /\ (, \ , ..... .-1 ...... '-l... /.,,'~,le J, i;,r. ,_1-.. :.... I •1,1,./t.,~; s, ,) r\. 5, ,., I bl;.,:."-. l sat.I t\.l ~~f ,,. ltu14· 1, 'bf O l t,~ l L ~V-<lL ~ He fl,n~ ., ,,p.-, /\15 ,-, •. , . .., ,·.r, ' il,,~r l'L11~-l l.11 ,r O 111•,· /_ S1' -:r :·o Tr,,!, ~\.'V • .. ,,•.11> · .. L SM\ ','!rl 1, •• lt,,;,1 :;11·11,;h1 1:1 [111:k so . "'" •·J~~u 1:<J·,v·-11 v.•··t1i·1 P r r1.,111,! \"l.ik, -----------0 '·"'"' II I ' '·' ())• '/ ;! ~~ I "i .... ,l: ;· ;.-. ,( , , "'-' ~ q, ~ •: ~ ' •, I --. ,J· . ,. 11;'.' ' ,, RCCCIVCO BY ·-1:1---------- . .•• . .. ;•~ I :~• ; , ; . .~I~ " 1 .... ':i; .. } ~\ l). ., L " ~; _,:I,, ,-1 4-· lh, ..... , 1hnut.m,4 1."l --~ f It \:I , 1' 1 u•.r, -i1v \' ,11 .~11'..-r~ •r, l,.,. ., ,1 ,11,~ I •'f 11, •. I• •·~•, f4'0d 11 f•1l1I r:11 .... , ... ', flit .11 ,flt '· ·t•"l',' A ,. •11bh 1 11: 11;tr•1r· ~. ri ~.,; •1 ,r,1 ,. ' ;l ( 11 •P. ~ ~ 1 1 I ':: •·•,I ·I •; • I i, ·l• 1, .,· ., P•,1tt-Jt,' . II ,r,+ t l;1ultw, f f'.~l .111 l'>.t-. ll, ~ /I r M t,$-f-1 t •i:: H1a• :i:: H,•v1•11:1I Ai15114 P,111•• 1 ,,1 I CHAIN Fe ST DY " . . • t'lll 0 f\'1Jtlh111. J -~' j(l 'lfll.ul., I I• I ,,,, A II.I"'"•" NI 1/'ILI• •• (8 : &71-1 ll4 f\tuwoht_ A:7 ,., , 1 ',"\--~• A 1\,1 j•J 11 ll -·~ r'l1uViUJ., i , H!.1 ·~· • taJ11) liSl--410 ----•.v~ 11 rm rl ~-_J .JJ l 11t,1 w M.J,•JI.,_ H• ,., -~---,, ' l1..1u, ·-~ ·.~ ' " ~ --' ) scr, CA (.;t1Jril ",•in ••111,,, I I, :_.t., . 1·, • ,all I r,.f;{'t-ir ,i \.I• '14\1",ft • 4tJ61;i,) 8f fl r: rH, er INl-()Rt, TION ------------- f· r I I I h •t 1.-11~,f,•1 I 1 ,. •., 1•111, .. l'11m.,..• L-(''t,. 'i 1 41 '-(~ ,-u SI I --' / I NI' l~u•-r, ,t,11 111 \'••• ,, w .. , I r ... tu1pl111 !lJi'li ,. ,,. :'",.,I 'C1,;f hr llf·SCRIPTION ·~I.,. ~-.. 1 , ·-I t--Gdh . "'"' 1J Ji ~Jl4 I J 1,-, ' ,, ,'t,.,,.t.~~~---........_., l., J :1 ·. ~ t.h( ~-,,,_ l. r >-._ ~ t(.._ ,. -PLE l Yl'L CODI S fl ..... ,t,Jol.,h• \1\1,11,q l) DL•,, ,C. ',-Yu 7 ------------------(UIJND [ ll>F C OU, jf A I f,,• ,, • f I l."t"IJ I!,·• ,r i J'l ,,.., .•• Ill! .• I~ l. i-J ., I, ·..,I l• J l •\ Ii 41 •• • •, 1-. , 'lf"."I,• ,, ,1.,,1, fl,t•. 11 1,l -~, 1 l.1•f111 Jj1Jj i I • rl•.., RII 1-l• I I U I JQUISH O 6'1' ,-- RI'.. Ut-.SlH) Sl·N\IICES I ~ ... ., II" , .. I I I •· ' I ( I I. ' I -~ I J !l ., 'I L - RECEIVCO Y rltr I ,r 1f'111u tt, ~ l hAu ,11 I ,, I ""t' •,·Jill..t ·'•J'l't4:' '•• 111 t-•, ,-~I •v lho l1•1··· ar<l \•I ,tf1l11 n· 11 li>l'tt 1' II •,,..,,a.,••·-,t , 1,1 'I-< 1,"' : , v1i f• ·~1111•,,11,t:u .11!C•f1,r1rtn ... , .. .,,,,hi'.f1i\ I>•.~ :,1 r.4-t..S-~ 1·•.-r-i't•v].:.,,l,!1\il'~i~d~ ... •1 /HJ.(',;,;,·~ <rl 1 ' , . .. >;. •> b.: i• : ' t;~ :'' ~· ,. ._ . . . ,, J : " . . ,f ~ ,,: ' . . , L I~ b: 1 , ~ ; ; , ] 1 1 :. ,~ -: ri ~ r .. : 1~ - ~ ~ } ; l, . , ~ .h l r . 5 4 , ,: : ~ J! tti l • .;' -' i.- t l 1 . .. I '. ·L ·i ' } J' .. .:.: ~,; ... . -:i,i , i : : t~ ! ; 1w! ~ 1i:: : I - - . 1\ , .' ~ ! ii ' ,I . ~ ~ •• ,i ~ 'f ~ 7 ·:~ ~ i ,'i_ ~ · j• ~ i ;1 ' 'j. . ~t .• ., .:, I! ft '! .\ ; AIR-SOUND-HYDRONIC PROFESSIONALS HVAC Test and Balance Report PROJECT: Reef CONTRACTOR: ARCHITECT: ENGINEER: 2290 Cosmos Court Carlsbad, CA MSC ID Studios McParlane & Associates REPORT CERTIFICATION NO: 41506 REPORT CERTIFICATION DATE: January 20, 2023 REVIEWED AND APPROVED BY: Michael Conboy ICB / TABB Certified Contractor 457 E. Arrow Hwy, Ste. D, Azusa, CA 91702 TEL: 626-915-8117 FAX: 626-915-8112 E-MAIL: ;_1\~pci;1trt.J,,ir!~i,la_11l:l:.(f1Jgi11_:1it_ri_,.1JJ ~-~-----=~•-·~-----~•JO,~----,-.,.~-·,,,,,._,__ .~. ~...,.~ 4.,,. • ._"'I" __ •~--~ _,--~ -.:-r'"_....-;--:i. .-,;,_---.,,,....,,, ........ .,,_ •, -..:;:;~---2:·,---;r, ... -~..__ ~,.;,--•-•• ~-:---_.____..___;i:.:;.-:&·~.....---... ~s.::..,, .,.------.-;-:·~,--.--=•-~·.....- j 1 STATE OF CALIFORNIA <!Contractors ~fate 'JLiren 'e ,ioarb Pursuant to Chapter 9 of Division 3 of the Business and Professions Code and the Rules and Regulations of the Contractors State License Board, the Registrar of Contractors does hereby issue this license to: MICHAEL CONBOY INC cffu, ASSOCIATED AIR BALANCE to engage in the business or act in the capacity of a contractor in the following classification(s): D62 -AIR AND WATER BALANCING B -GENERAL BUllDING CONTRACTOR Witness my hand-and seal this day, May 9, 2008 Issued December 21, 2004 REPLACEMENT /41±~ Registrar of Contractors This license is the property of the Registrar of Contractors, is not transferrable, and shall be returned to the Registrar upon demand when suspended, revoked, or invalidated for any reasoI1. It becomes void if not renewed. 851730 Lu:ense Number : ' t t T" Im?: zr--,-•-.,.~---=• ~-~-~-J i 3L-24 (REV. 12-07) $ OSP 07 1C346D AUOIT NO: 44.a744i TB0945108C Certification# 12/8/2022 Certification Date 12/31/2024 Valid Through ~ c:amACA110lf BOARD ntE The Sheet Metal Industry International Certification &Jard Cert ifi,es that - associated air balance Has successfully completed the requirements for TABB Contractor Labor Co-Chf:i.rperson • • ~t~~~ Maiagmient Co-Chairpeison I:s.-JL~· ICB!T ABB Administntor INl'EIINATIOIW. CERIW'ICA11ml IIGlollD TB1044482S Certification # 5/13/2022 Certification Date 12/31/2024 Valid Through #0728 1S0/IEC 17024 Pllf'IIOfffl8l Certification Program The Sheet Metal Industry International Certification Board Certifies that William James Scrimmager Jr Has successfully completed the requirements for TABB Supervisor ' . kUw.A t~ ~-Management Co-Chairman ~ L ~ ICBtr ABB Administrator CX0466110S Certification t:t- 1/3/2023 Certification Dae 12/31/2025 Valid Through MERMl1aUI. ~TIDN IIOAIID 11E The Sheet Metal Industry International Certification Board Certifies that Mich ad A Con boy Has successfully completed the requirements for TABB Commi,ssioning Supervisor Labor Co-Chairperson . . ~t~~-Maiaganent Co..Chairpetson n.~.~- ICBffABB Administrator ACT VAV AK w ATC WB BP WG CAV DP CD OT CE CFM CF CL CR DB DD DNL EMS ENT ESP 457 E. Arrow Hwy., Suite D., A,usa, CA 91723 Tel: (626) 915-8117 Fax: (626) 915-8112 Email: associatedairbalanee@gmail.com -Actual -Variable Air Volume Box -Free Area Factor -Watts -Automatic Temperature Control -Wet Bulb -Bypass (Damper, Value, ETC) -Water Gauge -Constant Air Volume Box -Differential Pressure -Ceiling Diffuser -Differential Temperature -Ceiling Exhaust Diffuser -Cubic Feet Per Minute -Coefficient Factor -Center Line -Ceiling Return Inlet -Dry Bulb -Direct Drive -Data Not Listed -Emergency Management System -Entering -External Static Pressure un,•0,,0,01,r,. ,_ "'-""""''"'''° .,"'"""" .. ..,• .. ·•o,o,,r~ ABBREVIATI_ONS FH -Flow Hood (Measures CFM Dlrectly, FPM and AK Factors Not Requiredl FPM -Feet Per Minute FPVAV -Fan Powered Variable Air Volume Box GPM -Gallons per Minute HP -Horsepower KW -Kilowatts L/S -Liters Per Second MB -Mixing Box NA -Not Applicable/ Access NM -Not Measured NVL -No Valid location OSA -Outside Air PD -Pressure Drop RA -Return Air REQ -Required RPM -Revolutions per Minute SA -Supply Air SFO -Smoke Fire Damper SP -Static Pressure SWR -Sidewall Return sws -Side Wall supply TDH -Total Dead Head TP -Thermal protected Reef-Calsbad Table of Contents System Page Number EX HP-1 (diffussers) 1 EX HP-2 (diffussers) 2 EX HP-3 {diffussers) 3 EX HP-4 (diffussers) 4 EX HP-5 (diffussers) 5 EX HP-fi (diffussP.rs) fi EX HP-7 (diffussers) 7 EX HP-8 (diffussers) 8 EX HP-9 {diffussers) 9 EX HP-10 {diffussers) 10 EX HP-11 (diffussers) 11 EX HP-12 (diffussers) 12 EX HP-13 (diffussers) 13 EX HP-14 {diffussers) 14 EX HP-15 (diffussers) 15 EX HP-16 (diffussers) 16 EX HP-17 (diffussers) 17 EX HP-19 {diffussers) 18 EX HP-20 (diffussers) 19 EX HP-23 {diffussers) 20 EX HP-25 (diffussers) 21 EX HP-26 (diffussers) 22 EX HP-27 (diffussers) 23 EX HP-30 (diffussers) 24 EX HP-32 (diffussers) 25 EX HP-33 (diffussers) 26 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-1 Room Number 5Upp1y 0204 1 0203 2 0202 3 OSA Roof 1 Remarks: Size 24X24 24X24 24X24 24X14 03+032 Type Ak CD 1.00 CD 1.00 CD 1.00 Open 0.44 Date: 1/17/2023 Technician: W.S Page 1 Design Actual FPM CFM FPM CFM .. 100 * 105 .. 300 * 307 .. 250 " 255 Total 650 667 375 165 377 166 Total 165 166 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-2 Room Number Supply 0211 1 0210 2 OSA Roof 1 Remarks: Size 24X24 24X24 8X8 03+032 Type Ak co 1.00 CD 1.00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page 2 Design Actual FPM CFM FPM CFM . 300 " 311 * 300 .. 309 Total 600 620 170 75 172 76 Total 75 76 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-3 Room Number Supply 0200 1 0200 2 0200 3 0200 4 CSA Roof 1 Remarks: Size 24X24 24X24 24X24 24X24 BXB 03+032 Type Ak CD 1.00 co 1.00 CD 1.00 CD 1.00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page 3 Design Actual FPM CFM FPM CFM * 400 * 407 1r 400 ... 391 * 400 .. 400 * 400 * 409 Total 1,600 1,607 261 115 263 116 Total 115 116 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-4 Room Number supply 0201 1 0201 2 0201 3 0201 4 0201 5 0201 6 OSA Roof 1 Remarks: Size 8" 8" 8" 8" 8" 8" 8X8 03+032 Type Ak RD 1.00 RD 1.00 RD 1.00 RD 1.00 RD 1.00 RD 1.00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page4 Design Actual FPM CFM FPM CFM • 200 * 205 .. 200 .. 199 * 200 * 210 .. 200 * 206 .. 200 * 200 .. 200 * 202 Total 1,200 1,222 352 155 357 157 Total 155 157 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-5 Room Number supp1y 0208 1 0207 2 0207 3 0217 4 0216 5 0216 6 0216 7 OSA Roof 1 Remarks: Size 24X24 24X24 24X24 24X24 12" 12" 12" 10X10 03+032 Type Ak CD 1.00 CD 1.00 CD 1.00 CD 1.00 RD 1.00 RD 1.00 RD 1.00 Open 0.55 Date: 1/17/2023 Technician: W.S. Page 5 Design Actual FPM CFM FPM CFM * 100 .. 102 .. 100 .. 109 .. 100 " 103 .. 100 .. 99 * 400 * 398 .. 400 * 404 * 400 " 412 Total 1,600 1,627 636 350 639 351 Total 350 351 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-6 Room Number 5UPPIY 0214 1 0215 2 CSA Roof 1 Remarks: Size 24X24 24X24 8X8 03+032 Type CD CD Open Ak 1.00 ·1.00 0.44 Date: 1/17/2023 Technician: W.S. Page 6 Design Actual FPM CFM FPM CFM ,. 300 * 316 " ~00 .. 544 Total 800 860 318 140 321 141 Total 140 141 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-7 Room Number Supply 0216 1 0216 2 0216 3 0216 4 0216 5 0216 6 OSA Roof 1 Remarks: Size 10" 14X14 14X14 10" 10" 12" 10X10 03+032 Type RD SW SW RD RD RD Open Ak 1.00 1.00 1.00 1.00 1.00 1.00 0.55 Date: 1/17/2023 Technician: W.S. Page7 Design Actual FPM CFM FPM CFM * 300 * 303 .. 325 .. 324 ,. 325 .. 327 .. 300 " 295 .. 300 .. 290 .. 450 .. 425 Total 2,000 1,964 600 330 610 336 Total 330 336 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-8 Room Number supply 0213 1 02·13 2 OSA Roof 1 Remarks: Size 24X24 24X24 axa 03+032 Type Ak CD 1.00 CD 'I.OD Open 0.44 Date: 1/17/2023 Technician: W.S. Page 8 Design Actual FPM CFM FPM CFM * 500 * 502 • 500 • 510 Total 1,000 1,012 477 210 479 211 Total 210 211 Diffuser And Grille Test Data Job Name: Reef-Ca!sbad System: Existing HP-9 Room Number Supply Corridor 1 0133 2 Open Area 3 Open Area 4 0139 5 Corridor 6 Corridor 7 OSA Roof 1 Remarks: Size 8" 24X24 14X14 14X14 24X24 48X3 48X3 10X10 03+032 Type RD CD SW SW CD LO LO Open Ak 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.55 Date: 1/17/2023 Technician: W S. Page 9 Design Actual FPM CFM FPM CFM .. 215 * 211 .. 50 .. 52 .. 250 * 262 " 250 .. 260 .. 250 .. 259 • 215 .. 221 • 215 .. 225 Total 1,445 1,490 573 315 578 318 Total 315 318 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-10 Room Number :,ucDIV 0100 1 0100 2 0100 3 0100 4 0100 5 OSA Roof 1 Remarks: Size 48X3 48X3 48X3 48X3 48X3 BXB 03+032 Type Ak LD 1.00 LO 1.00 LD 1.00 LO 1.00 LD 1.00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page 10 Design Actual FPM CFM FPM CFM * 360 * 362 .. 360 • 369 * 360 * 372 * 360 * 377 * 360 " 378 Total 1,800 1,858 375 165 381 168 Total 165 168 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-11 Room Number Supply 0134 1 0135 2 0136 3 Open Area 4 Open Area 5 0138 6 OSA Roof 1 Remarks: Size 24X24 24X24 24X24 14X14 14X14 24X24 BXB 03+032 Type CD CD CD SW SW CD Open Ak 1.00 ·1.00 1.00 1.00 1.00 1.00 0.44 Date: 1/17/2023 Technician: W.S. Page 11 Design Actual FPM CFM FPM CFM .. 325 .. 327 .. 325 "' 320 * 450 "' 427 ... 300 • 312 " 300 .. 316 * 300 • 288 Total 2,000 1,990 477 210 483 213 Total 210 213 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-12 Room Number :Supply 0122 1 0·123 2 0123 3 0123 4 0124 5 0131 6 Open Area 7 0125 8 OSA Roof 1 Remarks: Size 24X24 24X24 24X24 24X24 48X3 24X24 48X3 24X24 8XB 03+032 Type Ak CD 1.00 CD ·1.00 CD 1.00 CD 1.00 LO 1.00 CD 1.00 LO 1.00 CD 1.00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page 12 Design Actual FPM CFM FPM CFM * 50 .. 52 • '100 • 104 .. 100 * 107 * 100 * 108 * 250 * 254 .. 120 .. 121 * 230 .. 225 .. 50 .. 53 Total 1,000 1,024 602 265 610 268 Total 265 268 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-13 Room Number Supply 0102 1 0102 2 0102 3 CSA Roof 1 Remarks: Size 14X14 14X14 14X14 axa 03+032 Type Ak SW 1.00 SW 1.00 SW 1.00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page 13 Design Actual FPM CFM FPM CFM .. 650 " 634 ♦ 850 .. 827 .. 650 .. 642 Total 1,950 1,903 261 115 269 118 Total 115 118 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-14 Room 1 Number I supply 0103 1 0103 2 0103 3 OSA Roof 1 Remarks: Size 14X14 14X14 14X14 8X8 03+032 Type Ak SW 1.00 SW 1.00 SW 1.00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page 14 Design Actual FPM CFM FPM CFM * 600 ., 598 .. 600 .. 566 ,. 400 ,. 404 Total 1,600 1,568 307 135 310 136 Total 135 136 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-14 Room Number suoory 0106 1 0105 2 0104 3 OSA Roof 1 Remarks: Size 24X24 24X24 24X24 8X8 03+032 Type Ak CD 1.00 CD too CD 1.00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page 15 Design Actual FPM CFM FPM CFM * 300 * 312 * 250 ., 240 • 250 * 242 Total 800 794 307 135 311 137 Total 135 137 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-16 Room Number Supply 0107 1 0107 2 OSA Roof 1 Remarks: Size 24X24 24X24 8X8 03+032 Type Ak CD 1.00 CD 1.00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page 16 Design Actual FPM CFM FPM CFM * 500 * 510 . 500 • 516 Total 1,000 1.026 409 180 415 183 Total 180 183 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-17 Room Number Supply 0100 1 0100 2 0100 3 0100 4 CSA Roof 1 Remarks: Size 16" 16" 16" 16" 18X10 03+032 Type Ak RD 1.00 rm 1.00 RD 1.00 RD 1.00 Open 1.25 Date: 1/17/2023 Technician: W.S. Page 17 Design Actual FPM CFM FPM CFM .. 750 * 758 " 750 * 702 ,. 750 • 740 * 750 • 734 Total 3,000 2,994 400 500 404 505 Total 500 505 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-19 Room Number Supply 0100 1 0100 2 0100 3 0100 4 OSA Roof 1 Remarks: Size 16" 1G" 16" 16" 18X10 03+032 Type Ak RD 1.00 RD 1.00 RD 1.00 RD 1.00 Open 1.25 Date: 1/17/2023 Technician: W.S. Page 18 Design Actual FPM CFM FPM CFM * 750 .. 752 * 7!i0 ... 743 * 750 * 761 " 750 * 755 Total 3,000 3,011 400 500 410 513 Total 500 513 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-20 Room Number Supply 0112 1 011·1 2 OSA Roof 1 Remarks: Size 24X24 24X24 axa 03+032 Type CD CD Open Ak 1.00 ·1.00 0.44 Date: 1/17/2023 Technician: W.S. Page 19 Design Actual FPM CFM FPM CFM . 300 .. 303 • 300 . 311 Total 600 614 227 100 229 101 Total 100 101 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-23 Room Number supply 0115 1 0114 2 0107 3 0107 4 OSA Roof 1 Remarks: Size 24X24 24X24 16" 16" 8X8 03+032 Type Ak CD 1.00 CD ·t.00 RD 1.00 RD 1 00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page 20 Design Actual FPM CFM FPM CFM • 150 • 155 • 100 . '106 • 375 "' 372 . 375 • 377 Total 1,000 1,010 318 140 327 144 Total 140 144 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-25 Room Number Suppfy 0118 1 U118 L OSA Roof 1 Remarks: Size 12" 1L" 8X8 03+032 Type Ak RD 1.00 KU 1.UU Open 0.44 Date: 1/17/2023 Technician: W.S. Page 21 Design Actual FPM CFM FPM CFM * 500 * 505 .,, bUU .. l:>09 Total 1,000 1.014 341 150 347 153 Total 150 153 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-26 Room Number Supply 0119 1 0·1·19 2 OSA Roof 1 Remarks: Size 12" '12" BXB 03+032 Type Ak RD 1,00 RD ·1 00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page 22 Design Actual FPM CFM FPM CFM * 500 * 509 A 500 • 515 Total 1,000 1,024 364 160 372 164 Total 160 164 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-27 Room Number supply 0109 1 0'!08 2 OSA Roof 1 Remarks: Size 24X24 24X24 8X8 03+032 Type CD CD Open Ak 1.00 1.00 0.44 Date: 1/17/2023 Technician: W.S. Page 23 Design Actual FPM CFM FPM CFM * 300 " 315 • 300 • 322 Total 600 637 227 100 235 103 Total 100 103 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-30 Room Number supply 0101 1 0101 ~ OSA Roof 1 Remarks: Size 48X3 48X::.I BXB 03+032 Type LO LU Open Ak 1.00 1.00 0.44 Date: 1/17/2023 Technician: W.S. Page 24 Design Actual FPM CFM FPM CFM .. 250 * 255 " 250 " 257 Total 500 512 545 240 551 242 Total 240 242 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-32 Room Number 5uppfy 0103 1 0103 2 0103 3 0103 4 0103 5 0103 6 OSA Roof 1 Remarks: Size 14X14 14X14 14X14 14X14 14X14 14X14 8X8 03+032 Type Ak SW 1.00 GW 1.00 SW 1.00 SW 1.00 SW 1.00 SW 1.00 Open 0.44 Date: 1/17/2023 Technician: W.S. Page 25 Design Actual FPM CFM FPM CFM • 180 " 182 * 100 • 177 * 180 * 172 " 180 * 168 • 180 * 184 * 100 ,. 101 Total 1,000 984 182 80 194 85 Total 80 85 Diffuser And Grille Test Data Job Name: Reef-Calsbad System: Existing HP-33 Room Number 5upp1y 0120 1 0·120 2 OSA Roof 1 Remarks: Size 12" 10" axa 03+032 Type Ak RD 1.00 RD 1 00 Open 044 Date: 1/17/2023 Technician: W.S. Page 26 Design Actual FPM CFM FPM CFM * 500 .. 499 • 300 ,. L!:Jo Total 800 795 284 125 296 130 Total 125 130 GENERAL NOTES· ®. v \. 5..., , .6 I MEC~ANICAL ARSl FLOOfl PLAN SltfiWTES .:..--•· - ~® ~ t) 2. - TI 1 ~ 3 El ~ CL ... ~-==~-:.....- --.d'T-.~ ~ < <.) ::, < ; LL °' w < w ~ Ck: ~ 0 V 0 1 0 <) ~ w.fCtt>J,llCAL r!RSTA..OOR Pi>-N M2.l j ~ ~~ 1 I MECHANICAL SECOND FLOOR PLAN , .. ,..: .3 EB GENERAL NOTES SHEET NOTES· S::0:~":::...~~~~- • -~'1-- ~ --·-·-~-- ~ <( u 0 ~ ~ < w u w ;. a:: 5 u 0 1 0 u ~ MECl<ANlCAI. ScCQNOFLOOR Pl.AN M2.2 Hazardous Materials Questionnaire County of San Diego, Department of Environmental Health and Quality PO Box 129261, San Diego, CA 92112-9261 Record ID#: Not in System Plan Check#: DEH2022-HHMBP-012382 Balance Due: $87.00 (858) 505-6700 (800) 253-9933 www.sdcdehq.org Business Name Reef Business Contact Tim Seaman Telephone# Plan File# (619} 993-8846 Project Address 2290 COSMOS CT City CARLSBAD State CA Zip Code 92011-1517 APN# 213-050-44-00 Applicant Applicant E-Mail Applicant Telephone# Tim Seaman tim@championpermits.com (619) 993-8846 The following questions represent the tac lty's actlvHles, T the spec fie pro ect sc pt on_ PART 1-EIRE PEPARJMENJ -HAZARDOUS METERIALS DIVISION· OCCUPANCY Cl,ASSIFJCATION: (Not required for projects within the City of Sen Diego.) Indicate by selecting the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are selected, Applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: B Faclllty"s Square Footage {including proposed project): 5000 D Explosive or Blasting Agents □ Organic Peroxides □ Water Reactives D Corrosives □ □ Compressed Gases Flammable/Combustible Liquids □ □ Oxidizers Pyrophorics □ Cryogenics D Other Health Hazards □ Highly Toxic or Toxic Materials D None of These □ Flammable Solids □ Unstable Reactives □ Radioactlves PART H; SAN DIEGO COUNJY DEPARJMENJ OF ENVIRONMENTAL HEALTH -HAZARDOUS MAJER/ALS DIVISION CHMDI· 11 the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, in person al 5500 Overland Ave., Suite 110, San Diego, CA 92123, or by phor.e at (858) 505-6700 prior to issuance of a building permit. FEES ARE REQUIRED. Project Completion Date: YES NO 1. D Iii 2. □ llil 3. D 4. □ 5. □ 6. □ 7. □ 8. D llil D llil llil llil llil Is your business listed on the reverse side of this form? (check all that apply). Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, or 200 cubic feet? Will your business handle carcinogens or reproductive toxins In any quantify? Wilt your business use an existing, or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). D D □ CaiARP Exempt CalARP Required CalARP Complete Review Date; PART m; SAN DIEGO COUNJY AIR POLLUTION CONTROL DISJRICT CAPCD): II the answer to Question #1 is 'Yes' and the answer to Question #2 is 'No', the applicant must contact the APCD prior to the issuance of a building or demolition permit. If any answer to Questions #3, #4, or #5 is 'Yes', the applicant must contact the APCD prior to the issuance of a building or demolition permit. II the answer to Question #3 or #4 Is 'Yes', the applicant may need to submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation (some residential projects may be exempt from the notification requirements). Contact the APCD at 10124 Old Grove Road, San Diego, CA 92131 or telephone (858) 586-2600 for more information. YES NO 1. i!!I D 2. i!!I □ 3. □ llil 4. □ llil Will any existing building materials be disturbed as part of this project? (tt the answer is 'Yes', an asbestos survey may be required.) Has a survey been per1ormed lo determine the presence of asbestos containing materials? Will the project involve handling or disturbance of any asbestos containing materials? Will the project involve the removal of any load supporting structural member? 5 □ 6. D llil D Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http:/lwww.sdapcd.org/info/factslpermits.pdf (ANSWER ONLY IF QUESTION 5 IS 'YES') Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? Search the California School Directory at http:1/www.cde.ca govire/sd/ for public and private schools or contact the appropriate school district. Briefly describe business activities: Briefly describe proposed project: Women's apparret Tenant Improvement I declare under penalty of perjury that to the best of my knowledge and belief, the responses made herein are true and correct. 11!1; Fees Acknowledged: ll!l Tim Seaman Name of Owner or Authorized Agent FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: BY: EXEMPT OR NO FURTHER INFORMATION REQUIRED COUNTY-HMD" T. Yousif !-IG~MTlil'le 9/28/2022 APCD (l ..... FOR OFFICIAL USE ONLY RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY COUNTY-HMO APCD 9/1612022 Date DATE; __________ _ RELEASED FOR OCCUPANCY COUNTY-HMO APCD •A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. DEHQ_HMD_HMBP _Questionnaire v 2.0 (812021) Printed on: 9/28/2022@ 11 :42 PM OFFICE USE ONLY SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE RECORD ID # ___________________ 1 PLAN CHECK# _________________ _ Project Address (include suite) 'o'o--C... -:::> ['I\ (.) '::, Mailing Address (include suite) S~J'A.--L Business Contact City City BP DATE State Zip Code APN# State Zip Code Plan File# The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH -HAZARDOUS MATERIALS DIVISION (HMO}: If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 170, San Diego. CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 1. 2. 3. 4: 5. 6. 7. 8. YES NO § I ~ I (for new construction or remodeling projects) Is your business listed on the reverse side of this form? (check all that apply). Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 2 00 cubic feet? Will your business store or handle carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 1 0)? Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). 0 CalARP Exempt I Date Initials □ CalARP Required I Date Initials □ CalARP Complete I Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCOI: The following questions are intended to identify the majority of air pollution issues at the planning stage. Your project may require additional measures not identified by these questions. Residences are typically exempt, except-single building with more than four dwelling units and those with more than one detached residential buildings on the property-e.g. granny flats [+Excludes garages & small outbuildings not used as dwelling units]. If yes is answered for the questions below please see link for further instructions: here or for more comprehensive requirements, please contact apcdcomp@sdapcd.org or call {858) 586-2650. 1. V\/111 the project disturb 100 square feet or more of existing building materials? If yes, submit an asbestos survey to apcdcomp@sdapcd.org, □YOES s· V\/111 any load supporting structural members be removed? If yes, submit an asbestos survey and demolition notification to 2. apcdcomp@sdapcd.org at least 10 working days prior to starting the demolition of a load bearing structure. A notification is required even if no asbestos is present in the structure. 3. □ □ □ (ANSWER ONLY IF QUESTION 1 IS YES) V\/111 100 square feet or more of friable asbestos material be disturbed? If yes. submit a not1ficat1on of asbestos removal to apcdcomp@sdapcd.org at least 10 working days pnor to starting asbestos removal. 4 □ V\/111 any equipment or operations be installed that may require an APCD Permit to Operate? Please see the reverse side of this form for typical equipment requiring an APCD permit. If yes, contact APCD prior to the issuance of a building permit. Briefly describe business activities: yc.1r<L- I declare un er r:,enal(y gf ~rjury that to the best of my knowledge and belief t '---~ .s~ M ~ ---it"'-''-""---~"'-----------0'~ I ob IO r Name of Owner or Authorized A en! Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _________________________________ ~ BY: _____________________________ _ DATE: __ _,_/_~__,_/ __ _ EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO• APCD COUNTY-HMO APCD COUNTY-HMD APCD .. *A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other perm1tt1ng requirements may still apply HM-9171 (01/22) County of San Diego -DEH -Hazardous Materials Division Building Permit Finaled Revision Permit Print Date: 02/01/2023 Job Address: 2290 COSMOS CT, CARLSBAD, CA 92011-1517 Permit No: Status: (city of Carlsbad PREV2022-0159 Closed -Finaled Permit Type: BLDG-Permit Revision Work Class: Commercial Permit Revision Parcel#: 2130504400 Track#: Valuation: $0.00 Lot#: Occupancy Group: B Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type:V-B Bathrooms: Occupant Load: 547 Code Edition: 2019 Sprinkled: Yes Project Title: Orig. Plan Check#: CBC2022-0201 Plan Check#: Description: REEF LIFESYLE: DELTA 'C' REMOVAL OF SINGLE USE RESTROOM AND CEILING BAFFLES Applicant: CHAMPION PERMITS TIM SEAMAN PO BOX 5955 CHULA VISTA, CA 91912 (619) 993-8846 FEE BUILDING PLAN CHECK FEE (manual) Total Fees: $120.00 Building Division Property Owner: LV COSMOS COURT LLC 2290 COSMOS CT CARLSBAD, CA 92011-1517 Total Payments To Date: $120.00 Applied: 12/22/2022 Issued: 01/11/2023 Finaled Close Out: 02/01/2023 Final Inspection: INSPECTOR: Balance Due: AMOUNT $120.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560f I www.carlsbadca.gov ('city of Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION Development Services Building Division 1635 FaradayAvenue 442-339-2719 www.carlsbadca.gov 8a15 . -CBC2022-0201 . . DELTA C Orrg1nal Plan Check Number . Plan Rev1s1on Number Prlev 2£:f)?-7' 0/5/ Project Address 2290 Cosmos Court, Carlsbad CA 92011 G IS f R --/D f d s b . 1 Removal of single use restroom & ceiling baffles enera cope o evmon e erre u m1tta : -------~----------- CONTACT INFORMATION: Name Michael McDonald Phone 858-523-9836 ________ Fax _____________ _ Add 236 S Sierra Ave c· Sollana Beach z· 92075 ress ____________________ 1ty ______ ,p ____ _ Email Address mcdonald@idstudiosinc.com Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: [j] Plans D CalcU,lations D Soils D Energy D Other 2. 3. Describe revisions in detail List page1s) where each revision is shown Refer to narrative attached "221104_DEL TA C_Construction Change 01_Narrative" Refer to attachment 4. Does this revision, fn any way, alter the exterior of the project7 D Yes [j] No 5. Does this revision add ANY new floor area(s)? D Yes 6. Does this revision affect any fire related 1;ssues? D Yes 7. ls this a complete set? D Yes (Ill No -Ofgitllly ,i,i[jnJJd tly fl.tik<J :,J!cDori~ld =<" S M j k e MC DO n a I d g~:.;,~,~s.,~~~,,:,~nald@ldstud,o>'nc ,,m 0°10 SiuOlos, ~ ignature .o"'"'""·"·'' o,"""·"·o,· 1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 442-339-27 l 9 \I\IWw.carlsbadca.gov □ No ~ No D 11.11.2022 ate Email: building@carlsbadca.gov