HomeMy WebLinkAbout1594 MARBRISA CIR; VILLA 52; CBC2021-0466; PermitPERMIT REPORT
Commercial Permit
Print Date: 06/07/2022
Job Address: 1594 MARBRISA CIR, # VILLA 52, CARLSBAD, CA 92008
Permit Type: BLDG-Commercial Work Class: Deck
Parcel#: Track#:
Valuation: $16,024.00 Lot#:
Occupancy Group: R2 Project#:
#of Dwelling Units: Plan#:
Bedrooms:
Bathrooms:
Construction Type:VB
Orig. Plan Check#:
Plan Check#:
Project Title:
Description: VILLA 52; DECK REPAIR/ REPLACE LIKE FOR LIKE AS NEEDED
Applicant: Property Owner:
NOAA GROUP GRAND PACIFIC RESORT SERVICES LP
DAN TALENT
4990 N HARBOR DR
SAN DIEGO, CA 92106-2371
(619) 297-8066
FEE
STRONG MOTION -COMMERCIAL (SMIP)
BUILDING PLAN CHECK
5900 PASTEUR CT, # STE 200
CARLSBAD, CA 92008-7330
(760) 827-2512
BUILDING PLAN REVIEW-MINOR PROJECTS (PLN)
SB1473-GREEN BUILDING STATE STANDARDS FEE
Total Fees: $283.49 Total Payments To Date: $283.49
{city of
Carlsbad
Permit No: CBC2021-0466
Status: Closed -Fina led
Applied: 12/08/2021
Issued: 01/27/2022
Finaled Close Out: 06/07/2022
Inspector:
Final Inspection:
Balance Due:
CRenf
05/10/2022
AMOUNT
$4.49
$180.00
$98.00
$1.00
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
Ccicyor
Carlsbad
Job Address 1594 MarBr!sa Clrclt't, vma 5~
COMMERCIAL
BUILDING PERMIT
APPLICATION
B-2
Plan CheckC8£! l02 I -O'/ ~/,,,
Est. Value
PC Deposit "::IJ ~
Date ____ .Z,,fJZ../
Suite: Muldpl• APN: 211-130-02
Tenant Name #I: Grand Pacific MarBrisa Owners Association, Inc. Lot#:_N_IA ____ vear Bullt: _2_00_9 ________ _
Year Bullt:_2_00_9 __ Occupancy:_R_-2 __ Construction Type:~ Fire sprlnklers:®fESQNo A/C:0YESONo
BRIEF DESCRIPTION OF WORK; REPAIR IN KIND OF SlRU<.,IURAL MEMBERS ANO FlNISHE3/ WATERPROOFINO (IN KIND PER ORIGINAL
PERMITTED Pl.ANS) 0\JE TO TERMITE ANOW.'\TER INTRUSION DAMAGE:. IOTAL AREAS T.B.O. UPON !NVESTIOATIVE DEMOLITION.
□ Addltlon/New: ____________ New SF and Use, __________ New SF and Use
______ SF Deck, ------~SF Patio Cover, ________ SF Other (Specify) ___ _
0Tenant Improvement: _____ SF,
____ SF,
Existing Use: _______ Proposed Use: ______ _
Existing Use: Proposed Use: ______ _
□ Pool/Spa: ____ .SF Additional Gas or Electrical Features? ____________ _
0 Solar:. ___ KW,. ___ .Modules, Mounted: 0Roof 0Ground
0 Reroof:. _______ ,.... ___________________________ _
0 Plumbing/Mechanlcal/Electtlcal
[l] Other: WATERPROOFING AND FR~INO REPAIRS AT EXISTING BUILDING. BALCONY FRAMING REPAIRS TO ONLY OCCUR AT
ONE BALCONY--THE FRONT (NE) FACING SECOND FLOOR EXIT EGRESS BALCONY.
PRIMARY APPLICANT
Name: 0;:in Talan!, NOAA Group Inc
Address: 49go N. Harbor or.
City: San Diego
Phone: (858) 736-1508
State,._c_A __ .Zlp: 92106
Email: dant@noaainc.com
DESIGN PROFESSIONAL
Name: Joseph Hal<Mek, NOAA Group !n.
Address: 49t10 N. Harbor Dr.
City: San Diego State:_c_A __ Zlp: 92106
Phone: 618-297-8016
Email: Jch@r,oaalno.com
PROPERTV OWNER
Name: Grand Paclflo MarBrisa Owners Assoclallon, Inc.
Address: 1594 NarB11sa C1rc!e
City: Garlsoad State:~Zlp:._02_00_• ___ _
Phone· 1ao.431,a500
Email: harnold@gpr"e11orts.com
CONTRACTOR OF RECORD
Business Name:_M_c_co_n_t,_ac_li .. ng,_ __________ _
Addres 504 Jones Road
Citv Oceanside Stat~ CA Zii.,~sa
Phone:. 760.433.7700
Email:. JasonP@mc-contractin .com ---
Architect State License: C19128 CSLB License#: 973520 Class s -------Carlsbad Business License# (Required): s,0s0110,2-01-2022
APPLICANT CERTIFICATION: /certify that/ have read the application and state thattheabove lnformattonlscorrectandthat the
Information on the planslsaccurate. /agree to comply with all City ordinances end State laws relating to building
construct/on. _ •, /<?I /1' /
NAME {PRINT): Dan Talant SIGfl:C~~ DATE: 10/28/2021
1635 Faraday Ave Carf!bad,CA 92008 ?h. 76Q.602-2719fa,c~760-60MJ5: Email• Bulldlng@carJsbadca goy
REV. 07/21
IDENTIFY WHO WILL PERFORM THE WORK BY COMPLETING (OPTION AJ OR (OPTION BJ BELOW:
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. I also affirm under
penalty of perjury one of the following declarations:
0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of
the work which this permit is issued. Policy No. _________________________ _
l!!I I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name:-'-''-'-"-' -'"-"-"-'-°'-c_,_m.._p_,,,., ___________ _
Policy No. 54326272 Expiration Date: _,---11 ___ 12=''----------------------
D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to
become subject to the workers' compensation Laws of California. WARNING: Fallure to secure workers compensation coverage is unlawful and shall subject an
employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the
Labor Code, interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name: _____________________ .Lender's Address: _____________________ _
CONTRACTOR PRINT: Jason Pearson, MC Contracting SIGN: Jason Pearson::"1,;1~\\\;'~·:;·~,;; DATE: 1/27/22 --------
(OPTION BJ: OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s)
licensed pursuant to the Contractor's License Law).
01 am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
D "Owner Builder acknowledgement and verification form" has been filled out, signed and attached to this application. Proof of identification attached.
D Owners "Authorized Agent Form" has been filled out, signed and attached to this application giving the agent authority to obtain the permit on the owner' behalf
Proof of identification attached.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is
submitted or at the following Web site: http://www.leginfo.ca.gov/calaw.html.
OWNER PRINT: ____________ SIGN: _________ .DATE: ______ _
APPLICANT CERTIFICATION: SIGNATURE REQUIRED AT THE TIME OF SUBMITTAL
By my signature below, I certify that: I am the property owner or State of California Licensed Contractor or authorized to act on the property
owner or contractor's behalf. I certify that I have read the application and state that the above information is correct and that the
information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE,
INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY
ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA. An OSHA permit is required for excavations over 5'0'
deep and demolition or construction of structures over 3 stories in height.
APPLICANT PRINT: _________ _ SIGN: _________ DATE: _____ _
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
B-2 Page 2 of 2 Rev. 08/20
Building Permit Inspection History Finaled
( City of
Carlsbad
PERMIT INSPECTION HISTORY for (CBC2021-0466)
Permit Type: BLDG-Commercial Application Date: 12/08/2021 Owner: GRAND PACIFIC RESORT SERVICES
LP
Work Class: Deck Issue Date: 01/27/2022 Subdivision:
Status: Closed -Finaled Expiration Date: 08/23/2022 Address: 1594 MARBRISA CIR, # VILLA 52
IVR Number: 37479 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
01/31/2022 01/31/2022 BLDG-14 175569-2022 Passed Chris Renfro Complete
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/24/2022 02/24/2022 BLDG-18 Exterior 177261-2022 Passed Chris Renfro Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
05/10/2022 05/10/2022 BLDG-Final Inspection 182462-2022 Passed Peter Dreibelbis Complete
Checklist Item COMMENTS Passed
BLDG-Structural Final Yes
Tuesday, June 7, 2022 Page 1 of 1
SAN DIEGO REGIONAL
HAZARDOUS MATERIALS
QUESTIONNAIRE
Grand Pacific MarBrisa Owners
Association, Inc.
Project Address (include suite)
1594 MarBrisa Circle
Mailing Address (include suite)
1594 MarBrisa Circle , Bldg 5605 ("Villa 52")
Project Contact
Dan Ta/ant
Business Contact
Houston Arnold
City
Carlsbad
City
Carlsbad
Applicant E¥mail
dant@noaainc.com
OFFICE USE ONL V
RECORD ID # ___________________ 1 PLAN CHECK# __________________ ,
State
CA
State
CA
Telephone#
Zip Code
92008
Zip Code
92008
Telephone#
858-736-1508
BP DATE
760-431-8500
APN#
211-130-02
Plan File#
The following questions represent the facility's activities, NOT the specific project description.
PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: {not required for projects within the City gf $an
Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled,
applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal.
Occupancy Rating: Facility's Square Footage (including proposed project):
1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reaclives Corrosives
2. Compressed Gases 6. Oxidizers 10. Cryogenics
3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials
13.
14.
15.
Olher Health Hazards
None of These.
4. Flammable Solids 8. Unstable Reaclives 12. Radioactives
PART 11: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMD): If the answer to any of the
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 170, San Diego, CA 92123.
Call (858) 505-6700 prior to the issuance of a building permit.
FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy:
1.
2.
3.
4.
5.
6.
7.
8.
YES NO (for new construction or remodeling projects)
Is your business listed on the reverse side of this form? (check all that apply). □ !XI □ !XI Will your business dispose of Hazardous Substances or Medtcal Waste in any amount?
□ !XI Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500
pounds and/or 200 cubic feet?
□ □ □ □ □
IXI Will your business store or handle carcinogens/reproductive toxins in any quantity? IXI Will your business use an existing or install an underground storage tank? IXl Will your business store or handle Regulated Substances (CalARP)? !XI Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? IXI Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to
or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act).
0 CalARP Exempt
I
Date Initials
□ CalARP Required
Date Initials
□ CalARP Complete
Date Initials
PART 111: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT fAPCD): The following questions are intended to identify the majority of air pollution
issues at the planning stage. Your project may require additional measures not identified by these questions. Some residential projects may be exempt from APCD
requirements. If yes is answered for either questions 1, 2 or 5 or for more comprehensive requirements, please contact APCD at aocdcomp@sdcounty.ca.gqv;
(858) 586-2650; or 10124 Old Grove Road, San Diego, CA 92"131.
YES NO
1. IXI D Will the project disturb 100 square feet or more of existing building materials?
2. D !XI Will any load supporting structural members be removed?
3 IXI D (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by an individual that has passed an EPA-approved
building inspector course?
4. D 1K] (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Based on the survey results, will the project disturb any asbestos containing material? If yes, a
notification may be required at least 10 working days prior to commencing asbestos removaL Additionally, a notification may be required prior to
the removal of a load supporting structural member(s) regardless of the presence of asbestos,
5. D IX] Will the project or associated construction equipment emit air contaminants? See the reverse side of this form for typical equipment requiring an
APCO permit. Jf yes, contact APCD prior to the issuance of a building permit.
6. D D (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school
bounda ?
Briefly describe business activities: Briefly describe proposed project
Timeshare Units Repairs due to termites/beetles & water intrusion (exterior areas only)
01 12512022
Date
FOR OFF/CAL USE ONLY:
FIRE DEPARTMENT OCCUPANCY CLASSIFICATION·
BY: DATE: I I
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY
COUNTY-HM□• APCD COUNTY-HMO APCD COUNTY-HMO APCO
;\\(.10 ~., ~o
,,.. Rev;ewcd <;!; ii 01/25/2022-Mf ~
ONe/lrnt1<1fs
o.,eqc
"A stamp In this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply
HM-9171 (91181 Countv of San Dieao -DEH -Hazardous Materials Division
{city of
Carlsbad
STORM WATER STANDARDS
QUESTIONNAIRE
E-34
Development Services
Land Development Engineering
1635 Faraday Avenue
(760) 602-2750
www .carlsbadca.gov
To address post-development pollutants that may be generated from development projects, the city requires that new
development and significant redevelopment priority projects incorporate Permanent Storm Water Best Management
Practices (BMPs) into the project design per Carlsbad BMP Design Manual (BMP Manual). To view the BMP Manual,
refer to the Engineering Standards (Volume 5).
This questionnaire must be completed by the applicant in advance of submitting for a development application
(subdivision, discretionary permits and/or construction permits). The results of the questionnaire determine the level of
storm water standards that must be applied to a proposed development or redevelopment project. Depending on the
outcome, your project will either be subject to 'STANDARD PROJECT' requirements, 'STANDARD PROJECT' with
TRASH CAPTURE REQUIREMENTS, or be subject to 'PRIORITY DEVELOPMENT PROJECT' (PDP) requirements.
Your responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City
staff has responsibility for making the final assessment after submission of the development application. If staff
determines that the questionnaire was incorrectly filled out and is subject to more stringent storm water standards than
initially assessed by you, this will result in the return of the development application as incomplete. In this case, please
make the changes to the questionnaire and resubmit to the city.
If you are unsure about the meaning of a question or need help in determining how to respond to one or more of the
questions, please seek assistance from Land Development Engineering staff.
A completed and signed questionnaire must be submitted with each development project application. Only one completed
and signed questionnaire is required when multiple development applications for the same project are submitted
concurrently.
PROJECT NAME: Marbrisa Resort Villa 52 Repairs APN: 211-130-02
ADDRESS: 1594 Marbrisa Circle, Carlsbad, CA 92008
The project is (check one): D New Development )(Redevelopment
The total proposed disturbed area is: __ o ___ ft2 1,__0::__) acres
The total proposed newly created and/or replaced impervious area is: __ o __ ft2 '-_o __ ) acres
If your project is covered by an approved SWQMP as part of a larger development project, provide the project ID and the
SWQMP # of the larger development project:
Project ID _____ N_i_A ___________ SWQMP #: ____ N_i_A ____________ _
Then, go to Step 1 and follow the instructions. When completed, sign the form at the end and submit this with your
application to the city.
This Box for City Use Only
YES NO Date: Project ID:
City Concurrence:
□ □ By:
E-34 Page 1 of 4 REV 09/21
To determine if your project is a "development project", please answer the following question:
Is your project LIMITED TO routine maintenance activity and/or repair/improvements to an existing building
or structure that do not alter the size (See Section 1.3 of the BMP Design Manual for guidance)?
YES NO
□
If you answered "yes" to the above question, provide justification below then go to Step 6, mark the box stating "my project
is not a 'development project' and not subject to the requirements of the BMP manual" and complete applicant
information.
Justification/discussion: (e.g. the project includes only interior remodels within an existing building):
Project proposes repairs to existing building caused by beetles/termites and water intrusion.
No new development is proposed.
To determine if your project is exempt from PDP requirements pursuant to MS4 Permit Provision E.3.b.(3), please answer
the following questions:
Is your project LIMITED to one or more of the following:
1. Constructing new or retrofitting paved sidewalks, bicycle lanes or trails that meet the following criteria:
a) Designed and constructed to direct storm water runoff to adjacent vegetated areas, or other non-
erodible permeable areas; OR
b) Designed and constructed to be hydraulically disconnected from paved streets or roads; OR
c) Designed and constructed with permeable pavements or surfaces in accordance with USEPA
Green Streets uidance?
2. Retrofitting or redeveloping existing paved alleys, streets, or roads that are designed and constructed in
accordance with the USEPA Green Streets guidance?
3. Ground Mounted Solar Array that meets the criteria provided in section 1 .4.2 of the BMP manual?
YES NO
□ □
□ □
□ □
If you answered "yes" to one or more of the above questions, provide discussion/justification below, then go to Step 6, mark
the second box stating "my project is EXEMPT from PDP ... " and complete applicant information.
Discussion to justify exemption ( e.g. the project redeveloping existing road designed and constructed in accordance with
the USEPA Green Street guidance):
If you answered "no" to the above questions, your project is not exempt from PDP, go to Step 3.
E-34 Page 2 of 4 REV 09/21
Complete the questions below regarding your redevelopment project (MS4 Permit Provision E.3.b.(2)):
Does the redevelopment project result in the creation or replacement of impervious surface in an amount
of less than 50% of the surface area of the previously existing development? Complete the percent
impervious calculation below:
Existing impervious area (A) = ____________ sq. ft.
Total proposed newly created or replaced impervious area (B) = ____________ sq. ft.
Percent impervious area created or replaced (B/A)'100 = _____ %
YES NO
□ □
If you answered "yes", the structural BMPs required for PDP apply only to the creation or replacement of impervious
surface and not the entire development. Go to step 6, check the first box stating, "My project is a PDP ... " and complete
applicant information.
If you answered "no," the structural BM P's required for PDP apply to the entire development. Go to step 6, check the first
box statin "M ro·ect is a PDP ... " and com lete a licant information.
Complete the question below regarding your Standard Project (SDRWQCB Order No. 2017-0077):
YES NO
Is the Standard Project within any of the following Priority Land Use (PLU) categories?
R-23 (15-23 du/ac), R-30 (23-30 du/ac), Pl (Planned Industrial), CF (Community Facilities), GC (General D D
Commercial), L {Local Shopping Center), R (Regional Commercial), V-B (Village-Barrio), VC (Visitor
Commercial), 0 (Office), VC/OS (Visitor Commercial/Open Space), Pl/O (Planned Industrial/Office), or
Public Trans ortation Station
If you answered "yes", the 'STANDARD PROJECT' is subject to TRASH CAPTURE REQUIREMENTS. Go to step 6,
check the third box stating, "My project is a 'STANDARD PROJECT' subject to TRASH CAPTURE REQUIREMENTS
... " and complete applicant information.
If you answered "no", your project is a 'STANDARD PROJECT'. Go to step 6, check the second box stating, "My project is
a 'STANDARD PROJECT' ... " and com lete a licant information.
D My project is a PDP and must comply with PDP stormwater requirements of the BMP Manual. I understand I must
prepare a Storm Water Quality Management Plan (SWQMP) per E-35 template for submittal at time of application.
□ My project is a 'STANDARD PROJECT' OR EXEMPT from PDP and must only comply with 'STANDARD PROJECT'
slormwater requirements of the BMP Manual. As part of these requirements, I will submit a "Standard Project
Requirement Checklist Form E-36" and incorporate low impact development strategies throughout my project.
0 My project is a 'STANDARD PROJECT' subject to TRASH CAPTURE REQUIREMENTS and must comply with
TRASH CAPTURE REQUIREMENTS of the BMP Manual. I understand I must prepare a TRASH CAPTURE Storm
Water Quality Management Plan (SWQMP) per E-35A template for submittal at time of application.
Note: For projects that are close to meeting the PDP threshold, staff may require detailed impervious area calculations
and exhibits to verify if 'STANDARD PROJECT' stormwater requirements apply.
)( My project is NOT a 'development project' and is not subject to the requirements of the BMP Manual.
Applicant Information and Signature Box
Applicant Name: __ D_a_n_T_a_la_n_t ____________ Applicant Title: Agent for Owner
Applicant Signature:~L ~ Date: 11/30/2021
E-34 Page 4 of 4 REV 09/21
To determine if your project is a PDP, please answer the following questions (MS4 Permit Provision E.3.b.(1 )):
1. Is your project a new development that creates 10,000 square feet or more of impervious surfaces
collectively over the entire project site? This includes commercial, industrial, residential, mixed-use,
and public development projects on public or private land.
2. Is your project a redevelopment project creating and/or replacing 5,000 square feet or more of
impervious surface collectively over the entire project site on an existing site of 10,000 square feet or
more of impervious surface? This includes commercial, industrial, residential, mixed-use, and public
development projects on public or private land.
3. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more
of impervious surface collectively over the entire project site and supports a restaurant? A restaurant is
a facility that sells prepared foods and drinks for consumption, including stationary lunch counters and
refreshment stands selling prepared foods and drinks for immediate consumption (Standard Industrial
Classification (SIC) code 5812).
4. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious
surface collectively over the entire project site and supports a hillside development project? A hillside
develo men! ro·ect includes develo ment on an natural slo e that is twent -five ercent or realer.
5. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more
of impervious surface collectively over the entire project site and supports a parking lot? A parking lot is
a land area or facility for the temporary parking or storage of motor vehicles used personally for
business or for commerce.
6. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more
of impervious street, road, highway, freeway or driveway surface collectively over the entire project
site? A street, road, highway, freeway or driveway is any paved impe,vious surface used for the
trans ortation of automobiles, trucks, motorc c/es, and other vehicles.
7. Is your project a new or redevelopment project that creates and/or replaces 2,500 square feet or more
of impervious surface collectively over the entire site, and discharges directly to an Environmentally
Sensitive Area (ESA)? "Discharging Directly to" includes flow that is conveyed overland a distance of
200 feet or less from the project to the ESA, or conveyed in a pipe or open channel any distance as an
isolated flow from the project to the ESA (i.e. not commingled with flows from adjacent lands).*
8. Is your project a new development or redevelopment project that creates and/or replaces 5,000 square
feet or more of impervious surface that supports an automotive repair shop? An automotive repair
shop is a facility that is categorized in any one of the following Standard Industrial Classification (SIC)
codes: 5013, 5014, 5541, 7532-7534, or 7536-7539.
9. Is your project a new development or redevelopment project that creates and/or replaces 5,000 square
feet or more of impervious area that supports a retail gasoline outlet (RGO)? This category includes
RGO's that meet the following criteria: (a) 5,000 square feet or more or (b) a project Average Daily
Traffic (ADT) of 100 or more vehicles per day.
10. Is your project a new or redevelopment project that results in the disturbance of one or more acres of land
and are expected to generate pollutants post construction?
11. Is your project located within 200 feet of the Pacific Ocean and (1) creates 2,500 square feet or more of
impervious surface or (2) increases impervious surface on the property by more than 10%? (CMC
21.203.040
YES NO
□ □
□ □
□ □
□ □
□ □
□ □
□ □
□ □
□ □
□ □
□ □
If you answered "yes" to one or more of the above questions, your project is a PDP. If your project is a redevelopment
project, go to step 4. If your project is a new project, go to step 6, check the first box stating, "My project is a PDP ... "
and complete applicant information.
If you answered "no" to all of the above questions, your project is a 'STANDARD PROJECT'. Go to step 5, complete the
trash ca ture uestions ..
* Environmentally Sensitive Areas include but are not limited to all Clean Water Act Section 303(d) impaired water bodies; areas designated as Areas of Special
Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); water bodies
designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and
amendments); areas designated as preserves or their equivalent under the Multi Species Conservation Program within the Cities and County of San Diego; Habitat
Management Plan; and any other equivalent environmentally sensitive areas which have been identified by the City
E-34 Page 3 of 4 REV 09/21