HomeMy WebLinkAbout2208 PALOMAR AIRPORT RD; CS; CBC2022-0153; PermitBuilding Permit Finaled (city of Carlsbad Commercial Permit Print Date: 02/16/2023 Job Address: 2208 PALOMAR AIRPORT RD, # CS, CARLSBAD, CA 92011 Permit No: Status: CBC2022-0153 Closed -Finaled Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel#: 2130201800 Track#: Valuation: $3,000.00 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Occupant Load: Plan Check#: Code Edition: Sprinkled: Project Title: Description: AT&T MOBILE: MODIFY EXISTING CELL SITE Applicant: Property Owner: SUDBERRY PROPERTIES CORE ONE CONSULTING US LTD BRETT COFFELT 4515 S MCCLINTOCK DR, # 217 TEMPE, AZ 85282-7376 5465 MOREHOUSE DR, # SUITE 260 SAN DIEGO, CA 92121-4714 (858) 546-3000 FEE BUILDING PLAN CHECK BUILDING PLAN REVIEW-MINOR PROJECTS (LDE) BUILDING PLAN REVIEW-MINOR PROJECTS (PLN) ELEC: OTHER COMPLEX ELECTRICAL FIRE Special Equipment (Ovens, Dust, Battery) SB1473-GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -COMMERCIAL (SMIP) Total Fees: $1,431.64 Total Payments To Date: $1,431.64 Applied: 05/11/2022 Issued: 11/10/2022 Finaled Close Out: 02/16/2023 Final Inspection: 02/02/2023 INSPECTOR: Renfro, Chris Contractor: BECHTEL INFRASTRUCTURE AND POWER CORPORATION 12245 KIRKHAM RD, # STE 100 POWAY, CA 92064-6162 (949) 372-4503 Balance Due: AMOUNT $267.80 $194.00 $98.00 $412.00 $458.00 $1.00 $0.84 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov ( City of Carlsbad JobAddre COMMERCIAL BUILDING PERMIT APPLICATION B-2 Pian Ch eek -·=£_-(~:~·'2~·~,;_=7 -_-~(~,_·)~5~3~ Est. Value , ~,o""O • rx> PC Deposit • Date . ____ APN: 21~-0'2-0 --{f'.-c,O ____ Year Built: ________ _ Year Built: __ _ Occupancy:___ Construction Type: __ ___________ New SF and Use, _________ New SF and Use ______ SF Deck, ______ SF Patio Cover, SF Other (Specify) ___ _ OTenant Improvement: ____ SF, ____ SF, Existing Use: ______ Proposed Use: _____ _ Existing Use: Proposed Use: _____ _ 0 Other: _________________________________ _ APPLICANT CERT/FICA T/ON: I certify that I have read the application and state that the above information is correct and that the information on theplansisaccurate. I agree to comply with all City ordinances and State laws relating to building construction. NAME (PRINT): :a(y \\:: 6-,f{J/;; SIGN: ~o ~--S::::-0ATE: 5jf,b.ozz._ 163S Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Bu1ldinp:@carlsbadca.gov REV. 04122 I Building Permit Inspection History Finaled (city of Carlsbad " PERMIT INSP'5CTION HISTORY for (CBC2022-0153) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Application Date: 05/11/2022 Owner: SUDBERRY PROPERTIES Issue Date: 11/10/2022 Subdivision: RANCHO AGUA HE DION DA POR OF Status: Closed -Finaled Expiration Date: 08/01/2023 Address: 2208 PALOMAR AIRPORT RD, # CS CARLSBAD, CA 92011 IVR Number: 40564 Scheduled Actual Inspection Type Inspection No. Date Start Date 02/02/2023 02/02/2023 BLDG-34 Rough 202109-2023 Thursday, February 16, 2023 Electrical Checklist Item COMMENTS BLDG-Building Deficiency BLDG-Final Inspection 202110-2023 Checklist Item BLDG-Building Deficiency BLDG-Structural Final BLDG-Electrical Final COMMENTS Inspection Primary Inspector Status Passed Chris Renfro Passed Chris Renfro Reinspection Inspection Passed Yes Passed Yes Yes Yes Complete Complete Page 1 of 1 January 24, 2022 TELECOM MANAGEMENT GROUP s;, W.:0,0, '[),,.,,,,, 'R '1kt T.J. Burmesch, P.E. Lead Market Engineer Bechtel Infrastructure and Power Corp. 4030 E. Quenton Drive, Ste. 101-E Mesa, AZ. 85215 CITY Subject: Structural Analysis for AT&T's Proposed Equipment Installation on Existing Rooftop Site Name: Palomar Airport Site Number: NS0026 FA Number: 10145831 Site Address: 2208 Palomar Airport Road, Carlsbad, CA 92008 Dear Mr. Burmesch: Telecom Management Group (TMG) has completed a structural analysis of the above referenced site to determine its adequacy for the installation of AT& T's new antenna and equipment as shown in the following page. This analysis assumes that the existing structures, structure modifications and associated components have been properly constructed per original design and have been well maintained. The loads considered in this analysis were determined in accordance with the requirements of the California Building Code, 2019 Edition, and the ANSI/TIA-222-H (Structural Standard for Antenna Supporting Structures and Antennas) for an ultimate design wind speed of 96 mph for San Diego County, California. Ss=0.979g, S1=0.357g, Site Class D, Risk Category 11. Our findings show that the existing mounts will be adequate to support AT&T's equipment installation. The new antennas will be installed on the existing pipe support inside the FRP enclosure on the rooftop. The proposed anchoring system is also adequate for the new cabinet. The analysis is based solely on information available to us as listed on the following page. This report is considered void if any of the listed information is incorrect. We trust that this report is satisfactory. If you have any questions regarding the analysis, please contact our office. Yours very truly, Telecom Management Group David Tan, P.E. (CA License C 58359) CBC2022-0153 2208 PALOMAR AIRPORT RD AT&T MOBILE MODIFY EXISTING CELL SITE 2130201800 5/12/2022 CBC2022-0153 TELECOM MANAGEMENT GROUP· 302 W Washington St. #150-6850, San Diego, CA 92103 · Tel (858) 248-7678 AT&T Analysis Report Page 2 Site No: NS0026, Palomar Airport Design Criteria & Information Wind 96 mph ultimate wind speed. Seismic Ss=0.979g, S1=0.357g, Site Class D, Risk Category IL Construction Drawings by Telecom Management Group, dated 01/21/2022. Documents Previous Structural Analysis by lnfinigy Engineering LLP, dated 9/17/2019. Site Photos. Proposed AT&T Antenna Loading Sector RAD New/ Antenna Description Dimensions Weight Center. Existing (in) (lbs) N 40'-1" (3) AIR Antenna 30.6x16x10.6 97 N (3) AIR Antenna 28x15.7x6.7 89 E (3) S8NHH-1 D658 72.9x12x7 .1 78 Alpha (3) QS6658-3e & E 72x12x9.6 78 40'-0" Beta E (3) RRUS 4478 814 13.4x8.3x18.1 60 & Gamma E (6) RRUS 32 26.7x12.1x6.7 53 E (3) Ketherin 80010965K 55.1x19.6x7.8 68 39'-9" E (3) RRUS 32 26.7x12.1x6.7 53 E (3) RRUS 4449 85/812 17.9x13.2x9.4 71 New AT&T Cabinets Loading Ant. Tip New Description Dimensions Weight Elev. /Existing (in) (lbs) -N (1) NetSure 7100 Power System 84x25.5x22 2500 (max.) Notes: 1. Any discrepancies in loading from this listing should be brought to TMG"s attention. Results of this evaluation cannot be used if the loading is different. AT&T Analysis Report Page 3 Site No: NS0026, Palomar Airport Conclusion The existing mounts have adequate capacity to support AT& T's equipment installation. The proposed anchoring system is also adequate for the new cabinet. Usage Antenna Mount <10% Cabinet Anchor 43% Assumptions and Limitations 1. This report is based solely on the information supplied to us as listed above, and the results, in turn, are only as accurate as data extracted from this information. This report is considered void if any of the listed information or assumptions state herein is inaccurate. 2. The antenna mounts, including any existing modifications to them, have been installed in accordance with original design drawings and are in satisfactory condition to carry their full design capacity. 3. Any existing modifications not listed in this report have not been considered in the analysis. 4. Antennas and equipment are as given in the table above. Assumptions made with regards to antenna and mount sizes, and their projected areas, are based on our best interpretation of the provided information and our best knowledge of industry practice. 5. Contractor shall inspect the condition of all mount members and connections prior to installation of proposed equipment; if there are any deficiencies or discrepancies, Contractor shall notify Engineer of Record. AT&T Analysis Report Page 4 Site No: NS0026, Palomar Airport APPENDIX· CALCULATIONS Analysis Subject Mathcad Page Number Drawing Sheet Reference 1. Design Load 1 - 2. Antenna Mount Analysis 2 Detail 4/A5 3. Cabinet Overturning Analysis 3 Detail 8/A5 NS0026 1/24/2022 1. Design Load: Wind Loads• Other Structures: ASCE 7-16 Ultimate Wind Pressures Wind Factor ~ Gust Effect Factor (G) ="' Kzt ~ 1.00 0 85 un111111te Wind Speed • 1 00 Exposure = 96 mph C The proposed antennas and equipment will be installed inside the existing FRP enclosure and will be shielded from wind. Seismic Loads: IBC 2018 Risk Category II Importance Factor (I) 1 00 Site Class D • code de( Class D • code default Ss (0 2 sec)= 97 90 %i S1 (1 0 sec)= 35.70 %9 Strength Level Forces A site specific ground motion analysis Is required for seIsmIcally isolated structures or with dampinQ systems see ASCE7 11 4 8 Fa= 1 200 Sms = 1 175 Sos= 0 783 Design Category= D Fv = 1 943 Sm1 = 0 694 So1 = 0 462 Design Category = D MECH AND ELEC COMPONENTS SEISMIC COEFFICIENTS Seismic Design Category O & lp•1 0, therefore see ASCE7 Sect10n 13 1 4 for except10ns Mech or Electrical Component · j Communication equipment, computers, instrumentation, and controls. I Importance Factor (Ip) Ip= 1.0 all other components Component Amplification Factor (ap) = Comp Response Modification Factor (Rp) = O.,er-Strength Factor (Oo) = Fp = 0 4apSdslpWp(1+2z/h)/Rp = not greater than Fp = 1 6SdslpWp = but not less than Fp = 0 3SdslpWp = Wequip := 97 lbf Fp := 0 . 376Wequip = 36 . 472· lbf Seismic Load Governs! 1 2 5 2 0 376 Wp 1 253 Wp 0 235 Wp h::!'I 40. 1 feet z::!11 40 1 feet z/h = 1 00 use Fp = 0 376 Wp Maximum Antenna Weight Total Seismic Load 1 of 4 ... ----·- NS0026 1/24/2022 2. Antenna Mount Analysis: (E) S1EEL PIPE ffi AN"TENN~ ~OUNTINC 'C::J BR>CKIT. 1YP Rendering ,._ 0 0 ...., Unity See attached Risa-3D output for Antenna Mount Analysis Resu It. Tmax := 69lbf Vmax := 226lbf Vallow := 3976lbf Tallow := 6385lbf (N) A~1ENNA ~ 0 0 Isl Shear Tension Reaction (LRFD) Shear Reaction (LRFD) Code Check (Env) No Cale > 1.0 90 1.0 75-90 50-75 • 0 -!)0 Allowable shear of 1/2" A307 bolt per previous SA Allowable tension of 1/2" A307 bolt per previous SA 2 of 4 IIIRISA A N(.M -1.,Hf K C'QMf \NY Company : ENGQUEST.lnc Designer : HY Job Number : NS0026 Model Name : Antenna Mount Node Boundary Conditions Node Label X k/in Y k/in Z k/in 1 N8 Reaction Reaction Reaction 2 N6 Reaction Reaction Reaction Hot Rolled Steel Properties Label E fksil G fksil Nu Therm. Coeff. [1e0°F-1l Densitv flb/ft31 Yield fksil 1 A36 Gr.36 29000 11154 0.3 0.65 490 36 2 A572 Gr.SO 29000 11154 0.3 0.65 490 50 3 A992 29000 11154 0.3 0.65 490 50 4 ASOO Gr.42 29000 11154 0.3 0.65 490 42 5 A500 Gr.46 29000 11154 0.3 0.65 490 46 6 A53 Gr. B 29000 11154 0.3 0.65 490 35 Member Primary Data L b I a e IN d o e d J No e S . /Sh ection ape T voe Desian List 1 M2 NS N7 PIPE 2.0 Beam Pioe 2 M3 N1 8 N8 RIGID None None 3 M4 N14 N6 RIGID None None Hot Rolled Steel Design Parameters Label Shae Len th in in M2 PIPE 2.0 96 Member Point Loads (BLC 1 : Dead) Member Label Direction Maqnitude [lb, lb-ftl 1 M2 z -45 2 M2 z -45 3 M2 z -49 4 M2 z -49 Member Point Loads (BLC 2 : EQ Front) Member Label Direction Maqnitude [lb, lb-ft] 1 M2 X -17 2 M2 X -17 3 M2 X -19 4 M2 X -19 Member Point Loads (BLC 3 : EQ Side) Member Label Direction Maanitude fib, lb-ftl 1 M2 y -1 7 2 M2 y -17 3 M2 y -19 4 M2 y -19 RISA-3D Version 19 [ Pipe Mount 3.r3d ] 1/22/2022 8:22:33 PM Checked By : GW Z Rot k-ft/rad Reaction Rv Fu fksil Rt 1.5 58 1.2 1.1 58 1.2 1.1 58 1.2 1.3 58 1.1 1.2 58 1.1 1.5 60 1.2 Materia Desiqn Rue A53 Gr. B Typical RIGID Typical RIGID Tvoical Function Lateral Location f/in, %)1 %45 %70 %35 %10 Location f/in, %)1 %45 %70 %35 %10 Location flin, %)1 %45 %70 %35 %10 Page 1 IIIRISA Company : ENGQUEST.lnc Designer : HY Job Number : NS0026 Model Name : Antenna Mount Member Distributed Loads Member Area Loads Basic Load Cases No Data to Print. .. No Data to Print... 1/22/2022 8:22:33 PM Checked By : GW BLC Descriotion Cateaorv X Gravity Y Gravitv Z Gravitv Point 1 Dead DL -1 4 2 EQ Front ELX -0.376 4 3 EQ Side ELY -0.376 4 Load Combinations Descriotion s olve P-Delta BLC Factor BL C Factor 1 Dead+-EQ Front Yes y 1 1.2 2 1 2 Dead+EQ Side Yes y 1 1.2 3 1 3 Dead+EQ Front Rev Yes y 1 1.2 2 -1 4 Dead+EQ Side Rev Yes y 1 1.2 3 -1 Load Combination Design Descriotion Service Hot Rolled Cold Formed Wood Concrete Masonrv Aluminum Stainless Connection 1 Dead+-EQ Front Yes Yes Yes Yes Yes Yes Yes Yes 2 Dead+EQ Side Yes Yes Yes Yes Yes Yes Yes Yes 3 Dead+EQ Front Rev Yes Yes Yes Yes Yes Yes Yes Yes 4 Dead+EQ Side Rev Yes Yes Yes Yes Yes Yes Yes Yes Envelope Node Reactions Node Label X llbl LC Y flbl LC Z [lb] LC MX flb-ftl LC MY flb-ftl LC MZ flb-ftl LC 1 NB max 31.75 1 50.248 2 226.32 3 0 4 0 4 41.231 2 2 min -68.739 3 -50.248 4 33.553 1 0 1 0 1 -41 .231 4 3 N6 max 50.69 1 32.192 2 225.367 1 0 4 0 4 0 4 4 min -13.701 3 -32.192 4 32.6 3 0 1 0 1 0 1 5 Totals: max 82.44 1 82.44 2 258.92 3 6 min -82.44 3 -82.44 4 258.92 2 Envelope A/SC 15TH (360-16): LRFD Member Steel Code Checks Code Check Loe in LC Shear Check Loe in LC hi*Mn z-z lb-ft Cb 0.068 90 1 0.015 6 4 1871.625 1 RISA-3D Version 19 [ Pipe Mount 3.r3d ] Page 2 NS0026 1/24/2022 2 Tmax Check := "Bolts are adequate" Vmax 2 J ----+ ----< 1 2 Tallow Va llow 2 "Bolts are not adequate" ---- 2 Tmax otherwise -----+ -----=5.786·% 2 Tallow 2 Vallow 3. Cabinet Overturning Analysis: NetSure 7100 POWER SYSTEM SYSTEM FEATURES DC OUTPUT VOLTAGE AC INPUT VOLTAGE RA TED OVTP\/T CAPACITY SYSTEM SHELF DISTRIBUTION PANEL PHYSICAL CHARACTERISTICS flWIEWORI< M'E WIDTH DEPTH HEIGHT RACK WEICHT WITHOUT BATTERIES WffH BATTERIES ACCESS ENVIRONMENTAL OPERATING STORAGE HUMIDITY \IEtrnLATION Et.11/Rfl SUPPRESSION SAFETY COMPLIANCE 25.8" -48 voe (NOIIINAI..) 208/H0 VM:. SINGLE PHASE (NOMINAL) 1000 AMPS AT -48 voe. 520 AMPS AT + 24 voe 250 AMPS AT -48 voe. 187.5 AMPS AT +24 voe 600 AMPS AT -48 voe. 520 A.IIPS AT +24 VDC RELAY RACK 25.5 INCHES 22 INCHES 84 INCHES 620 LBS. 2500 LBS. FRONT ACCESS FOR INSTALLATION. OPERATION ANO I.WNTENANCE -40 T TO 104 'F (-40 ·c TO 40 'C) CONTINUOUS OPERATION -40 'F TO 185 'F (-40 ·c TO 85 'C) o:; TO 95X RELATI\IE HUf.llOITY, NON-CONDENSING RECTIF!ERS/CONVERTERS ARE FAN-COOLED FRONT TO REAR CONFORIAS 10 FCC RULES PART 15, SUBPART 8, CLASS B ANO EN55022 CLASS B, RADIATED ANO CONDUCTED UL LISTED TO 1801. CUL. NEBS LE\IEL J CERTIF!EO NOTE: VERIFY IAOUNIINC HOLES FROM EQUIPMENT MANUFACTURER MANUAL PRIOR TO INSTALLATION (N) CABIN[T RELAY RACK FLOOR MOUNTING DIMENSIONS 4) J/4"0 HILT\ KB TZ7 CS W/ 4" MIN. EFFECTIVE DEPTH OF EMBED .. ICC ESR 4266 ~ [IF L 3 of 4 = "Bolts are adequate" NS0026 1/24/2022 MECH ANO ELEC COMPONENTS SEISMIC COEFFICIENTS Seismic Oes19n Category D & lp•1 O, therefore see ASCE7 Sect10n 13 I • for except10ns Mech or Electrical Component G,n,rators, batteri,s, 1nv,rt,rs, motors, transformers, and other ,1,ctrlcal components Importance Factor {Ip) Ip ~ 1.0 all other components Component Amplification Factor (ap) = Comp Response Modification Factor (Rp) = Over-Strength Factor (Oo} = Fp = 0 4apSdslpWp(1+2z/h)/Rp = not greater than Fp = 1 6SdslpWp = but not less than Fp = 0 3SdslpWp = Wcabi net := 250 0 l bf Fp := 0 .376·Wcabinet= 940 l b f Hcg := 36i n Dcabinet := 1 5in Mmax := Fp· Hcg = 2 . 82 · kip · ft Vmax := Fp = 0 . 94 · kip n := 2 .o 1 2.5 2 0 376 Wp 1 253 Wp 0 235 Wp h::!I 7 0 feet z::!I 7 0 feet z/h = 1 00 use Fp = 0 376 Wp Maximum Equipment Weight Seismic Force Equipment C.G. Anchor Spacing Moment Reaction Shear Reaction Overstrength Factorfor Connection Design See attached Hilti leport for Anchor Check, the proposed (4) 3/4" Hilti KB-m CS bolts with 4" embedment are adequate for proposed cabinet overturning. The minimum thickness of the slab is 6". 4 of 4 ..... ,:,,s., Hilti PROFIS Engineering 3.0.74 Specifier's comments: 1 Input data Anchor type and diameter: Item number: Effective embedment depth: Material: Evaluation Service Report: Issued I Valid: Proof: Stand-off installation: Kwik Bolt TZ2 -CS 3/4 (3 3/4) hnom2 2210312 KB-TZ2 3/4x6 1 /4 h8r,ect = 3.750 in., hnom = 4.500 in. Carbon Steel ESR-4266 7/1/2021 J 12/1/2021 Design Method ACI 318-14 / Mech eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plateR : Ix x ly x t = 25.800 in. x 18.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: Base material: Installation: no profile cracked concrete, 2500, fc' = 2,500 psi; h = 8.000 in. hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) R -The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, in.lb] ij z \~ 'C7,680 ' X ~ Input data and results must be checked for conformity with the existing conditions and ror plausib11lty! PROFIS Engineering ( c ) 2003-2022 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hllli AG, Schaan i : i i 5 • • ----------------------Hilti PROFIS Engineering 3.0.74 1.1 Design results Case Description Load case: Design loads Forces [lb)/ Moments [in.lb) N = -2,250; V, = 0; VY= -1 ,880; M, = 67,680; My= 0; M, = 0; Input data and results must be checked ror conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hiltl AG, Schaan Seismic yes Max. Util. Anchor[%] 43 2 i = 1 1 S • • ----------------------Hilti PROFIS Engineering 3.0.74 2 Proof I Utilization (Governing Cases) Loading Tension Shear Proof Concrete Breakout Failure Concrete edge failure in direction y- Design values [lb] Utilization Load Capacity PN / f3v [%] 3,140 7,434 43 /- 1,880 9,845 -I 20 Pv l; Utilization PN,v [%] Loadin--'g=--__________________ P_N ____________________ .=.=- Combined tension and shear loads 0.422 0.191 5/3 31 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! Input data and results must be checked fo, conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Status OK OK Status OK 3 i = i i S • • ----------------------Hilti PROFIS Engineering 3.0.74 4 Remarks; Your Cooperation Duties Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c) 2003-2022 Hilli AG, FL-9494 Schaan Hilti is a registered Trademark of Hilli AG, Schaan 4 1/22/22, 8:04 PM ATC Hazards by Location L\TC Hazards by Location Search Information Address: Coordinates: 2208 Palomar Airport Rd, Carlsbad, CA 92008, USA 33.1259663, -11 7.2760128 320 ft Carlsbad :GOLAND California~ Elevation: Timestamp: 2022-01-23T01 :04:39.9862 Hazard Type: Reference Document: Risk Category: Site Class: Seismic ASCE7-16 II □-default Basic Parameters Name Value Ss 0.979 S1 0.357 SMs 1.175 SM1 • null Sos 0.784 So1 • null * See Section 11.4.8 Go gle Description MCER ground motion (period=0.2s) MCER ground motion (period=1.0s) Site-modified spectral acceleration value Site-modified spectral acceleration value Numeric seismic design value at 0.2s SA Numeric seismic design value at 1.0s SA •Additional Information Name Value Description soc • null Seismic design category Fa 1.2 Site amplification factor at 0.2s Fv • null Site amplification factor at 1.0s CRs 0.9 Coefficient of risk (0.2s) CR1 0.91 Coefficient of risk (1.0s) PGA 0.428 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.513 Site modified peak ground acceleration v 320ft ' BRfSSI RAN San Marci Lake San Marcos Map data ©2022 Google, INEGI https://hazards.atcouncil.org/#/seismic?lat=33.1259663&Ing=-117.2760128&address=2208 Palomar Airport Rd%2C Car1sbad%2C CA 92008%2C USA 1 /2 1122122, 8:04 PM TL 8 SsRT 0.979 SsUH 1.088 SsD 1.5 S1RT 0.357 S1UH 0.392 S10 0.6 PGAd 0.5 • See Section 11.4.8 ATC Hazards by Location Long-period transition period (s) Probabilistic risk-targeted ground motion (0.2s) Factored uniform-hazard spectra! acceleration (2% probability of exceedance in 50 years) Factored deterministic acceleration value (0.2s) Probabilistic risk-targeted ground motion (1.0s) Factored uniform-hazard spectral acceleration (2% probability of exceedance in 50 years) Factored deterministic acceleration value (1.0s) Factored deterministic acceleration value (PGA) The results indicated here DO NOT reflect any state or local amendments to the values or any delineation fines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are provided by the U.S. Geological Survey Seismic Design Web Services. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. https://hazards.atcouncil.org/#/seismic?lal==33.1259663&Ing==-117.2760128&address==2208 Palomar Airport Rd%2C Carlsbad%2C CA 92008%2C USA 2/2 1/22/22, 8:04 PM l\TC Hazards by Location Search Information Address: Coordinates: Elevation: Timestamp: Hazard Type: ASCE 7-16 MRI 10-Year MRI 25-Year MRI 50-Year MRI 100-Year Risk Category I Risk Category 11 Risk Category Ill Risk Category IV 2208 Palomar Airport Rd, Carlsbad, CA 92008, USA 33.1259663, -117.2760128 320 ft 2022-01-23T01 :04:17.2532 Wind 67 mph 72 mph 77 mph 82 mph 89 mph 96 mph 102 mph 107 mph ASCE 7-10 MRI 10-Year MRI 25-Year MRI 50-Year MRI 100-Year Risk Category I Risk Category II Risk Category Ill-IV ATC Hazards by Location Carlsbad LEGOLAND California~ 320 ft ' l.ake San Morcos San Go gle Map data ©2022 Google, INEGI ASCE 7-05 72 mph ASCE 7-05 Wind Speed 85 mph 79 mph 85 mph 91 mph 100 mph 110 mph 115 mph The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authonty Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. Per ASCE 7, islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area ~ in some cases, this website will extrapolate past the last wind speed contour and therefore, provide a wind speed that is slightly higher. NOTE: For queries near wind-borne debris region boundaries, the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne debris region. Mountainous terrain, gorges, ocean promontories, and special wind regions shall be examined for unusual wind conditions. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this wP.hsifP. rlnP.s nnt imnlv ;:mnrnv;:il hv thP. nnvP.rninn h11ilrlinn r.nrlP. hnrliP.s rnsnnnsih1P. fnr h11ilrlinn r.nrlP. ;:innrnv;:il ;:inrl intP.rnrP.t;:itinn fnr thP. https://hazards.atcouncil.org/#/wind?lat=33.1259663&Ing=-117.2760128&address=2208 Palomar Airport Rd%2C Carlsbad%2C CA 92008%2C USA 1 /2 Hazardous Materials Questionnaire County of San Diego, Department of Environmental Health and Quality PO Box 129261, San Diego, CA 92112-9261 (858) 505-6700 (800) 253-9933 www.sdcdehq.org Record ID#: Not in System Plan Check#: DEH2022-HHMBP-012436 Balance Due: $87.00 Business Name AT&T Mobility Business Contact Sylvia Tello Telephone# Plan File# (619) 798-6759 Project Address 2208 Palomar Airport RD City CARLSBAD State CA Zip Code 92008 APN# 213-020-18-00 Applicant Jama Stephenson Applicant E-Mail Applicant Telephone# jamo.stephenson@coreoneconsultants.com (619) 798-6759 The following questions represent the facility's activities, NOT the specific project description. PART I· FIRE DEPARTMENT -HAZARDOUS METERIALS DIVISION: OCCUPANCY CLASSIFICATION: (Not required for projects within the City of San Diego.) Indicate by selecting the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are selected, Applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: u Faclllty's Square Footage (including proposed project): 200 □ Explosive or Blasting Agents □ Organic Peroxides □ Water Reactives □ Corrosives □ Compressed Gases □ Oxidizers □ Cryogenics □ Other Health Hazards □ Flammable/Combustible Liquids □ Pyrophorlcs □ Highly Toxic or Toxic Materials □ None of These □ Flammable Solids □ Unstable Reactives □ Radioactives PART U· SAN QIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS PIVJSION (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, in person at 5500 Overland Ave., Suite 110, San Diego, CA 92123, or by phone at (858) 505-6700 prior to issuance of a building permit. FEES ARE REQUIRED. Project Completion Date: YES NO 1. 00 □ 2. □ ~ 3. 4. 5. 6. 7. 8. D □ □ □ □ □ "' □ "' "' "' "' Is your business listed on the reverse side of this form? {check all that apply). Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, or 200 cubic feet? Will your business handle carcinogens or reproductive toxins in any quantity? Will your business use an existing, or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). D □ □ CalARP Exempt CalARP Required CalARP Complete Review Date: PART 111· SAN DIEGO COUNTY AIR POLLUTION CQNTRQL DISTRICT (APCD): If the answer to Question #1 is 'Yes' and the answer to Question #2 is 'No', the applicant must contact the APCD prior to the issuance of a building or demolition permit. If any answer to Questions #3, #4, or #5 is 'Yes', the applicant must contact the APCD prior to the issuance of a building or demolition permit. If the answer to Question #3 or #4 is 'Yes', the applicant may need to submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation {some residential projects may be exempt from the notification requirements). Contact the APCD at 10124 Old Grove Road, San Diego, CA 92131 or telephone (858) 586-2600 for more information. 1. 2. 3. 4. YES NO □ "' □ □ □ □ □ "' Will any existing building materials be disturbed as part of this project? (If the answer is 'Yes', an asbestos survey may be required.) Has a survey been performed to determine the presence of asbestos containing materials? Will the project involve handling or disturbance of any asbestos containing materials? Will the project involve the removal of any load supporting structural member? 5. 6. □ □ "' Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.org/infolfacts/permits.pdf (ANSWER ONLY IF QUESTION 5 IS 'YES') Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? Search the California School Directory at http://www.cde.ca.govlre/sd/ for public and private schools or contact the appropriate school district. □ Briefly describe business activities: Briefly describe proposed project: Wireless cellularfaclllty transmitting and receiving data modification to existing cell site by removing and adding antennas, and RRUs. I declare under penalty of perjury that to the best of my knowledge and belief, the responses made herein are true and correct. ~; Fees Acknowledged: ~ Jama Stephenson 9/23/2022 Name of Owner or Authorized Agent Date FOR OFFICIAL USE ONLY FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: BY: DATE: ___________ _ EXEMPT OR NO FURTHER INFORMATION RELEASED FOR BUILDING PERMIT BUT NOT FOR RELEASED FOR OCCUPANCY REQUIRED OCCUPANCY COUNTY-HMO* APCD COUNTY-HMO APCD COUNTY-HMO APCD ,,,o,, ,,, co 0 , Rf VIFvVH' C M. Martinez S!GJJATUR!: 10/13/2022 OATl •"', *A stamp In this box only exempts businesses from completing or updating a Hazardous Matena1s Business Plan. Other perm1ttIng requirements may still apply. DEHQ_HMD_HMBP _Questionnaire v 2.0 {8/2021) Printed on: 10/13/2022@ 2:25 PM