HomeMy WebLinkAbout2875 LOKER AVE E; ; CBC2022-0125; PermitBuilding Permit Finaled
{city of
Carlsbad
Commercial Permit
Print Date: 04/24/2023
Job Address: CARLSBAD, CA 92010-6626
Permit No:
Status:
CBC2022-0125
Closed -Finaled
Permit Type:
2875 LOKER AVE E,
BLDG-Commercial
2090832100
$250,177.29
Work Class: Tenant Improvement
Parcel#:
Valuation:
Occupancy Group: B
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition: 2019
Sprinkled: Yes
Project Title:
Track#:
Lot#:
Project#:
Plan#:
Construction Type:V N
Orig. Plan Check #:
Plan Check#:
Description: ZEST DENTAL: 5,379 SF OFFICE Tl (NO CHANGE IN USE) (NON-MEDICAL)
Applicant: Property Owner:
SHANNON MCINTYRE
3911 SORRENTO VALLEY BLVD, # 120
SAN DIEGO, CA 92121-1457
TECHBILT CONSTRUCTION CORPORATION
3575 KENYON ST, # SUITE 200
SAN DIEGO, CA 92110-5396
(415) 432-6021
FEE
BUILDING PLAN CHECK
BUILDING PLAN REVIEW-MINOR PROJECTS (LDE)
BUILDING PLAN REVIEW -MINOR PROJ ECTS (PLN)
CERTIFICATE OF OCCUPANCY
COMM/IND Tl -NON-STRUCTURAL
FIRE Plan Review (per hr -Regular Office Hours)
SB1473 -GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION -COMMERCIAL (SM IP)
Total Fees: $3,183.12 Total Payments To Date: $3,183.12
Applied: 04/15/2022
Issued: 07/18/2022
Finaled Close Out: 04/24/2023
Final Inspection: 04/11/2023
INSPECTOR: Renfro, Chris
Kersch, Tim
Contractor:
PACIFIC BUILDING GROUP
9752 ASPEN CREEK CT, # STE 150
SAN DIEGO, CA 92126-1082
(858) 552-0600
Balance Due:
AMOUNT
$1,013.04
$194.00
$98.00
$15.00
$1,558.53
$223.50
$11.00
$70.05
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
f?-'t,,,
{_ City of
Carlsbad
COMMERCIAL
BUILDING PERMIT
APPLICATION
B-2
Plan Check ~-Q{d.J
Est. Value c.itc:2'9), i7] . .;a
PC Deposit t/k l.,◊-13 , CJlf
Dat e L..f-(~-(21;)._
Suite:, _____ APN: 209·083-10-00 Job Address 285 LOKER AVE. EAST, CARLSBAD, CA 92010
Tenant Name#: ZEST DENTAL SOLUTIONS Lot #: ____ Year Built: _1_98_9 ________ _
Year Built:_1_98_9 __ Occupancy:_8 __ _ Construction Type:_v_N __ Fire sprinklersGYES0 NO A/C:OYESO No
BRIEF DESCRIPTION OF WORI<: EXISTING TENANT WITHIN AN EXISTING OFFICE BUILDNG. TENANT IMPROVEMENT WILL INCLUDE DEMO.
NEW WALL LAYOUT FOR LAB ANO RELOCATED BREAK ROOM. PLUMBING, ELECTRICAL AND MECHNICAL AND FINISH WORK.
0 Addition/New: ____________ New SF and Use, __________ New SF and Use
_______ SF Deck, _______ SF Patio Cover, SF Other (Specify) ____ _
[i]Tenant Improvement: _____ SF, Existing Use: _______ Proposed Use: ______ _
_ ..:.;s•.:...31.:...9 ___ SF, Existing Use: s Proposed Use: _8 ______ _
D Other: __________________________________ _
PRIMARY APPLICANT PROPERTY OWNER
Name: SHANNON MCINTYRE Name: TECHBILT CONSTRUCTION CORP.
Address: 3911 SORRENTO VALLEY BLVD, SUITE 120 Address; 3575 KENYON STREET, SUITE 200
City: SAN DIEGO State: CA Zip:,....:9;.:;.21.;.::2_1 --City: SAN DIEGO State: CA Zip :_9;;.;;2;.;.1.;.;10;....._ __
Phone: 415-432-6021 Phone: 619-223·1663
Email: SMCINTYRE@WAREMALCOMB.COM Email:--------------------
DESIGN PROFESSIONAL CONTRACTOR OF RECORD
Name: SHANNON MCINTYRE Business Name: ?§?J 0,,..,V\ f-v la", Id, h~ (tYowe
Address: 3911 soRRENTO VALLEY BLVD, su1Te 120 Address: ot,,5p .... A"::.P:0'.) (..,Y°--t". '-€.,.le::::. C,--tU, }:.;-.a \ SP
City: SAN 01EG0 State: CA Zip:_s_2,_2, ___ City: "'V\ Di €QO State: G4 Zip: ~ :i.\ )--(fJ
Phone: 415-432..i;o2, Phone: 1)'55 -~?.,;.( -.i-( I ?---~
Email: \.-,::1 l)..-(,Y\--l:::<-:r@>Y:'~<:::i:fi cb-J\·1 ',!, b(l 'J"' ov. \"' • < c.fv,
CSLB License #:~02.. ?-,it (.Q Class: ·p, (.,.-7-, L-i?\
Carlsbad Business License# (Required):fl ~J-9~
Email: SMCINTYRE@WAREMALCOMB.COM
Architect State License: _c_A __________ _
-bt,.QS.I 1. ,~~5
APPLICANT CERT/FICA TION: I certify that/ have read the application and state that the above information is correct and that the
information on t he,Plansisaccurate. /agree to comply with all City ordinances and State laws relating to building
construction. ~-
NAME (PRINT): SHANNON MCINTYRE SIGN: -~~-J-~-1-~~'-I--DATE:o4.12.2022
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442·339-2719 Email: 8uilding@carlsbadca.gov
REV. 04/22
lJJ
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON
SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO
PERMIT ISSUANCE.
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I herebyaf firm underpenaltyof perjurythatlam lfcensed under provisionsof Chapter 9 (commencing with Section 7000)of Division3
of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the
following declarations (CHOOSE ONE):
0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is Issued. Policy No .. ____________________________________________ _
-OR-
~I have and will maintain worker's compensation, as required by Sec:tion 3700 of the Labor Code, for the perform,tnce of the work for which this permit Is issued.
My workers' compensation insurance carrier nd licy number are: lnsuranceCompany Name: :Z. UR\ t:n N'!\,{;:~\C rte'\ \ N) \A€, AN£
Policy No. -\ Expiration Date: -=a::....!.1..C1,.___..L...:2.=-.,.~<-----------
-0R-0 Certificate of Exemption: I certify that in the performance of the work for which this permit Is issued, I shall not employ any person in any manner so as to become
subjec:t to the workers' compensation laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition t he to the cost of compensation, damages as provided for in Section 3706 of the labor Code,
interest and attorney's fees.
CONSTRUCTION LENDING AGENCY. IF ANY:
I hereby affirm that there is a construc:tion lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
lender's Name: _______________________ Lender's Address: _______________________ _
CONTRACTOR CERT/Ff CAT/ON; The applicant certifitJ that all documtflts and plans dtarly and accurately show alltxuting and proposed buUdings, structure,, acctH roads, and
utilities/ut/Ury casements. All proposed modifications and/or additions ore clearly lobe led on the site pion. Any potentiollv -,;sang detail within these pion, incon,irtenr with the sire plan are not
approved for construction and may be requirtd tD be altered or removtd. The city's approval of the application i, bostd on the prtmi<e thor the submitted documentJ and plan, show the correa
dimtnsions of; the propetty, buildings, .structur,s ond their setback$ /1om pro perry /jnes ond from one another; occess 1oods/eosem1nts., and vtilitits. Tht ~Jdsting and proposed us~ of 1ach building
as stortd is true and correct; oll easements and other tncumbronces to dt11etopment ha'fle been accurately shown and labt!ltd os well os all o,,..site grading/site prtpararfon. All improvements
existing on the prop8ry were completed In oca,rdonce with o/1 regulations in e>tisunct at the rim~ of their conr ucrion1 unless otherwise noted.
NAME (PRINT}: 1 eett (;Jue:NJ3..£: s1GNATURE:_/--1,,L.,,..,_'L ______ oATE:
Note: If the person signing above is an authorized agent for the contractor provide a letter of authorization on contractor lettertiead.
(OPTION B): OWNER-BUILDER DECLARATION:
J hereby afffrm that I am exempt from Contractor's License Law for the following reason:
O 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the struc:ture is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, hOwever, the building or improvement is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
-OR-D 1, as owner of the property, am exclusively contrac:ting with licensed contractors to construct the projec:t (Sec. 7044, Business and Professions Code: The
Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
-OR· 0 1 am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
AND,
0 FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit Issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder If it has not been constructed in its entirety by licensed
contrac:tors. / understand that acopyaf the applicable law, Section 7044 of the Business and Prafessians Code, isavailob/e upon request when this opp/icotion is
submitted orat the fa/lowin51 Website: http: I fwww.leginfo.ca.gavf colaw.htm/.
OWNER CERT/FICA TION; The applicant certifies that all documents and plans clearly and accurately ,how all e,iscing and proposed buildings, scrucrures, access roods, and utilitles/uriliry
,are menu . .All proposed modifications and/or oddirions ore cltorly labeled on the site plan. Any porenrial/y e,ining decal/ wlrMn these plans Inconsistent with rhe site plan ore nae approved for
consrruction and moy be required co be altered or removed. The clty"s approval of the oppllcocion is based on rM premise that the submicred documencs and plans show the correct dirMn<ions of;
the properry, buildings, srrucrures and their set bocks from property 1/nts ond from one another; acceu roods/easements, ond utmaer. The e,isting and proposed use of each building 01 stottd is trut
and wrrect; all easements and at her enwmbrances to developmeM have been occurately shown and labeled as well os all on•<ite grading/site preparation. AH improvemenu existing on the prop,rry
were compltl~d In occordonu wJth all regulations in existenct ot tht limt of thtir construction, unless otherwis~ nored.
NAME (PRINT): SIGN: __________ DATE: _____ _
Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner.
1635 Faraday Ave carfsbad,CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov
2 REV. 04/22
PERMIT INSPECTION HISTORY for (CBC2022-0125)
Permit Type: BLDG-Commercial Application Date: 04/15/2022 Owner: TECHBILT CONSTRUCTION
CORPORATION
Work Class: Tenant Improvement Issue Date: 07/18/2022 Subdivision: CARLSBAD TCT#74-21-PARCEL
Status: Closed -Finaled Expiration Date: 04/17/2023
IVR Number: 40044
MAP NO 15563
Address: 2875 LOKER AVE E
CARLSBAD, CA 92010-6626
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
Status
COMMENTS
11/16/2022 11/16/2022 BLDG-Final Inspection 196753-2022 Partial Pass Tim Kersch
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Taco isuued for 90 days to de-scope
work not completed on approved set of
plans.
04/11/2023 04/11/2023 BLDG-Final Inspection 207690-2023 Passed Tim Kersch
Monday, April 24, 2023
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
NOTES Created By
Angie Teanio
COMMENTS
Taco isuued for 90 days to de-scope
work not completed on approved set of
plans.
TEXT
619-279-6593 Jeff
Passed
Yes
Yes
Yes
Yes
Yes
Reinspection
Passed
No
Yes
Yes
Yes
Yes
Passed
Yes
Yes
Yes
Yes
Yes
Created Date
04/10/2023
Incomplete
Complete
Page 3 of 3
PERMIT INSPECTION HISTORY for (CBC2022-0125)
Permit Type: BLDG-Commercial Application Date: 04/15/2022 Owner: TECH BIL T CONSTRUCTION
CORPORATION
Work Class: Tenant Improvement Issue Date: 07/18/2022 Subdivision: CARLSBAD TCT#74-21-PARCEL
MAP NO 15563
Status: Closed -Finaled Expiration Date: 04/17/2023 Address: 2875 LOKER AVE E
IVR Number: 40044 CARLSBAD, CA 92010-6626
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial pass rough combo in walls only in Yes
lactation room
BLDG-34 Rough 190886-2022 Partial Pass Chris Renfro Reinspection Incomplete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
09/09/2022 09/09/2022 BLDG-17 Interior 191271-2022 Partial Pass Tim Kersch Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
09/22/2022 09/22/2022 BLDG-84 Rough 192327-2022 Passed Tim Kersch Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
09/28/2022 09/28/2022 BLDG-17 Interior 192831-2022 Passed Tim Kersch Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10/04/2022 10/04/2022 BLDG-44 193293-2022 Partial Pass Tim Kersch Reinspection Incomplete
Rough/Ducts/Dampers
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Phase 2 taco -break room. Yes
10/19/2022 10/19/2022 BLOG-85 T-Bar, Ceiling 194441-2022 Passed Tim Kersch Complete
Grids, Overhead
Monday, April 24, 2023 Page 2 of 3
Building Permit Inspection History Finaled
{city of
Carlsbad
PERMIT INSPECTION HISTORY for (CBC2022-0125)
Permit Type: BLDG-Commercial Application Date: 04/15/2022 Owner: TECHBIL T CONSTRUCTION
CORPORATION
Work Class: Tenant Improvement Issue Date: 07/18/2022 Subdivision: CARLSBAD TCT#74-21-PARCEL
MAP NO 15563
Status: Closed -Finaled Expiration Date: 04/17/2023 Address: 2875 LOKER AVE E
IVR Number: 40044 CARLSBAD, CA 92010-6626
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
07/20/2022 07/20/2022 BLDG-84 Rough 187251-2022 Passed Tim Kersch Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
07/25/2022 07/25/2022 BLDG-17 Interior 187608-2022 Partial Pass Tim Kersch Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/03/2022 08/03/2022 BLDG-44 188369-2022 Partial Pass Tim Kersch Reinspection Incomplete
Rough/Ducts/Dampers
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/16/2022 08/16/2022 BLDG-85 T-Bar, Ceiling 189256-2022 Passed Tim Kersch Complete
Grids, Overhead
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Phase 1 Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
08/31/2022 08/31/2022 BLDG-44 190269-2022 Partial Pass Tim Kersch Re inspection Incomplete
Rough/Ducts/Dampers
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Phase 2 taco -break room. Yes
09/07/2022 09/07/2022 BLDG-24 Rough/Topout 190887-2022 Partial Pass Chris Renfro Reinspection Incomplete
Monday, April 24, 2023 Page 1 of 3
....
Ccicyof
Carlsbad
PURPOSE
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
B-50
Development Services
Building Division
1635 Faraday Avenue
(760) 602-2719
www.carlsbadca.gov
This checklist is intended to help building permit applicants identify which Climate Action Plan (CAP) ordinance requirements
apply to their project. This completed checklist (B-50) must be included with the building permit application. The Carlsbad
Municipal Code (CMC) can be referenced during completion of this document by clicking on the provided links to each
municipal code section.
NOTE: The following type of pennits are not required to fill out this form
❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool
Consultation with a certified Energy Consultant is encouraged to assist in filling out this document. Appropriate
certification includes, but is not limited to: Licensed, practicing Architect, Engineer, or Contractor familiar with Energy
compliance, IECC/HERS Compliance Specialist, ICC GB Energy Code Specialist, RESNET HERS rater certified, certified
ICC Residential Energy Inspector/Plans Examiner, ICC Commercial Energy Inspector and/or Plans Examiner, ICC CALgreen
Inspector/Plans Examiner, or Green Building Residential Plan Examiner.
If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance,
check N/A and provide an explanation or code section describing the exception.
Details on CAP ordinance requirements are available at each section by clicking on the municipal code link provided. The
project plans must show all details as stated in the applicable Carlsbad Municipal Code (CMC) and/or Energy Code and
Green Code sections .
Project Name/Building
Permit No.: ZEST DENTAL BP No.: CBC2022-0125
Property AddresS/APN: 2875 LOKER AVENUE/2090831000
Applicant Name/Co.: SHANNON MCINTYRE/WARE MALCOMB
Applicant Address: 3911 SORRENTO VALLEY BLVD, SUITE 120, SAN DIEGO, CA 92121
Contact Phone: 415-432-6021 Contact Email: SMCINTYRE@WAREMALCOMB.COM
Contact information of person completing this checklist (if different than above):
Name:
Company
name/address:
Contact Phone: 415-432-6021
Contact Email:
Applicant Signature: ___ ~ ___ _,__..__ef..._.__ _______ Date: 05.20.2022
8-50 Page 1 of 7 Revised 04/21
Use the table below to determine which sections of the Ordinance checklist are applicable to your project. For
alterations and additions to existing buildings, attach a Permit Valuation breakdown on a separate sheet.
Building Permit Valuation (BPV) $ breakdown _9_2_7,_0_0_0 ____ _
I Conltrucllon TJ,e
0 Residential
□ New construction
D Additions and alterations:
□ BPV < $60,000
□ BPV ~ $60,000
D Electrical service panel upgrade only
□ BPV ~ $200,000
Ii] Nonresidential
□ New construction
l!!!!I Alterations:
l!!!!I BPV ~ $200,000 or additions~ 1,000
square feet
□ BPV ~ $1,000,000
□ ~ 2,000 sq. ft. new roof addition
Checldllt lbHn
A high-rise residential building is 4 or more stories, including a
Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor
area is residential use
2A*, 3A*, 1B, 2B, *Includes detached, newly constructed ADU 4A*, 3B,4A
N/A N/A All residential additions and alterations
1A, 4A 4A 1-2 family dwellings and townhouses with attached garages
only.
*Multi-family dwellings only where interior finishes are removed
1A, 4A* 1B,4A* and significant site work and upgrades to structural and
mechanical, electrical, and/or plumbing systems are proposed
1 B, 2B, 3B, 4B and 5
1B, 5
1B, 2B, 5 Building alterations of~ 75% existing gross floor area
2B,5 1 B also applies if BPV ~ $200,000
Cl1idcthiapproprlateboa,8alplalrlilnolapplcableandexcaplialllerna,and pnwlda111mn1J11SE
1. Energy Efficiency
Please refer to Cartsbad Municipal Code (CMC) 18.21.155 and 18.30.190,and the California Green Building Standards Code (CALGreen) for more
information. Appropriate details and notes must be placed on the plans according to selections chosen in the design.
A. D Residentialadditionoralteration~$60,000buildingpennitvaluation. D N/A _________ _
Details of selection chosen below must be placed on the plans referencing CMC D Exception: Horne energy score~ 7
(attach certification) 18.30.190.
Year Built Single-family Requirements Multi-family Requirements
D Before 1978 Select one option:
D Ductsealing D Attic insulation □Cool roof □ Attic insulation
D 1978 and later Select one option:
□ Lighting package □ Water heating Package
D Between1978and1991 Select one option:
D Ductsealing □ Attic insulation □Cool roof
D 1992 and later Select one option:
D Lighting package □ Water heating package
Updated 4/16/202 1 3
8. Ill Nonresidential* new construction or alterations~ $200,000 building pennit valuation,
or additions~ 1,000 square feet. See CMC 18.21.155 and CALGreen Appendix AS □ N/A
AS.203.1.1 Choose one: D .1 Outdoor lighting D .2 Restaurant service water heating (CEC 140.5)
□ . 3 Warehouse dock seal doors. D .4 Daylight design PAFs D .5 Exhaust air heat recovery □ N/ A
AS.203.1.2.1 Choose one: D .95 Energy budget (Projects with indoor lighting OR mechanical)
II!!! .90 Energybudget (Projectswith indoorlightingANDmechanical) □ N/A
AS.211.1 ** D On-site renewable energy:
~ N/A
AS.211.3** □Green power: (If offered by local utility provider, 50% minimum renewable sources)
El N/A
AS.212.1 D Elevators and escalators: (Project with more than one elevator or two escalators)
IX N/A
AS.213.1 D Steel framing: (Provide details on plans for options 1-4chosen)
IX N/A ________ _
• Includes hotels/motels and high-rise residential buildings
** For alterations.!: $1,000,000 BPVand affecting> 75% existinggrossfloorarea, OR alterations that add 2,000 square feet of new roof addition: comply
with CMC 18.30.130 (section 2B below) instead.
2. Photovoltaic Systems
A. D Residential new construction (for low-rise residential building pennit applications submitted after 1/1/20). Refer to 2019 California
Energy Code section 150.1(c)14 for requirements. If project includes installation of an electric heat pump water heater pursuant to
CAP section 38 below (low-rise residential Water Heating), increase system size by .3kWdc if PVoffset option is selected.
Floor Plan ID (use additional CFA #d.u. Calculated kWdc*
sheets if necessary)
Total System Size:
kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.)
*Formula calculation where CFA = conditional floor area, #du= number of dwellings per plan type
If proposed system size is less than calculated size, please explain.
kWdc
Exception
□
□
□
□
8. D Nonresidential new construction or alterations ~$1,000,000 BPV AND affecting ~75% existing floor area, OR addition that increases
roof area by i?l,000 square feet Please refer to CMC 18.30.130 when completing this section. *Note: This section also applies to
high-rise residential and hotel/motel buildings.
Choose one of the following methods:
□ Gross Floor Area (GFA)Method
GFA:
□ If< 1 O,OOOs.f. Enter: 5 kW de
Min. System Size:
□ If.!: 10,000s.f. calculate: 15 kWdcx (GFA/10,000) ••
kWdc
**Round building size factor to nearest tenth, and round system size to nearest whole number.
Updated 4/16/2021 4
□ Time-Dependent Valuation Method
Annual TDVEnergyuse:*** ______ .x .80= Min. system size: ______ kWdc
***Attach calculation documentation using modeling software approved by the California Energy Commission.
3. Water Heating
A. D Residential and hotel/motel new construction. Refer to CMC 18.30.170 when completing this section.
Provide complete details on the plans.
□ For systems serving individual dwelling units choose one system:
□ Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise
residential only)
□ Heat pump water heater AND PV system .3 kWdc larger than required in CMC 18.30.130 (high rise
residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential)
□ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher
□ Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors
□ Exception:
□ For systems serving multiple dwelling units, install a central water-heating system with ALL of the following:
□ Gas or propane water heating system
□ Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low-
rise residential)
□ Solar water heating system that is either:
□ .20 solar savings fraction
□ .15 solar savings fraction, plus drain water heat recovery
□ Exception:
B. D Nonresidential new construction. Refer to CMC 18.30.150 when completing this section. Provide
complete details on the plans.
□ Water heating system derives at least 40% of its energy from one of the following (attach documentation):
□ Solar-thermal □ Photovoltaics □ Recovered energy
□ Water heating system is (choose one):
□ Heat pump water heater
D Electric resistance water heater(s)
□Solar water heating system with .40 solar savings fraction
□ Exception:
It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to
demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a
performance approach to comply with energy-related measures will need to attach to this checklist separate calculations
and documentation as specified by the ordinances.
Updated 4/1 6/2 1 5
4. Electric Vehicle Charging
A D Residential New construction and major alterations*
Please refer to CMC 18.21.140 when completing this section.
D One and two-family residential dwelling or townhouse with attached garage:
D One EVSE Ready parking space required D Exception : _____________ _
D Multi-familyresidential· D Exception ·
Total Parking Spaces EVSE Spaces
Proposed EVSE (10% of total) Installed (50% of EVSE) Other "Ready" Other "Capable"
Calculations: Total EVSE spaces= .10x Total parking spaces proposed (rounded up to nearest whole number) EVSE Installed= Total EVSE
Spaces x .50 (rounded up to nearest whole number) EVSE other may be "Ready" or "Capable"
*Major alterations are: ( 1 )for one and two-family dwellings and townhouses with attached garages, alterations have a building permit
valuation2:$60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached
garages), alterations have a building permit valuation 2: $200,000, interior finishes are removed and significant site work and upgrades to
structural and mechanical, electrical, and/or plumbing systems are proposed.
*ADU exceptions for EV Ready space (no EV ready space required when):
(1) The accessory dwelling unit is located within one-half mile of public transit.
(2) The accessory dwelling unit is located within an architecturally and historically significant historic district.
(3) The accessory dwelling unit is part of the proposed or existing primary residence or an accessory structure.
(4) When on-street parking permits are required but not offered to the occupant of the accessory dwelling unit.
(5) When there is a car share vehicle located within one block of the accessory dwelling unit.
B. D Nonresidential new construction (includes hotels/motels) D Exception : ____________ _
Please refer to CMC 18.21.150 when completing this section
Total Parking Spaces
Proposed EVSE (10% of total) I Installed (50% of EVSE) I Other "Ready" I Other "Capable"
I I I
Calculation: Refer to the table below:
Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces
D 0-9 1 1
D 10-25 2 1
D 26-50 4 2
D 51-75 6 3
D 76-100 9 5
D 101 -150 12 6
D 151-200 17 9
D 201 andover 10 percent of total 50 percent of Required EV Spaces
Calculations: Total EVSE spaces= .1 Ox Total parking spaces proposed (rounded up to nearestwhole number) EVSE Installed = Total EVSE
Spaces x .50 (rounded up to nearest whole number) EVSE other may be "Ready'' or "Capable"
Updated 4/16/2021 6
5. Iii Transportation Demand Management (TOM): Nonresidential ONLY
An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT.
City staff will use the table below based on your submitted plans to determinewhetherornoryourpermit requires a TOM plan. lfTOM is applicable to your
pennit, staff will contact the applicant to develop a site-specific TOM plan based on the pennit details.
Acknowledgment:
Employee ADT Estimation for Various Commercial Uses
Use
EmpADTfor
first 1,000 s.f.
EmpADT/
1000 s .f.1
Office (all}2 20
Restaurant 11
Retaib 8
Industrial 4
Manufacturing 4
Warehousing 4
1 Unless otherwise noted, rates estimated from /TE Trip
Generation Manual, 1 (Jlh Edition
13
11
4.5
3.5
3
1
2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to
calculate employee ADT
3 Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
sample calculations;
Office: 20,450 sf
1. 20,450 sf/ 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf= 8 ADT
2. 9,334 sf -1,000 sf= 8,334 sf
3. (8,334 sf/ 1,000 x 4.5) + 8 = 46 Employee ADT
I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should
my pennit require a TOM plan and u erstand that n approved TOM plan is a condition of pennit issuance.
0 t 05.20.2022 ae: ______ _
Person other than Applicant to be contacted for TOM compliance (if applicable):
Name(Printed}: _________________ _ Phone Number. _____ _
Email Address: __________________ _
Updated 4/ 16/202 I 7
Building Permit Finaled
Revision Permit
Print Date: 04/24/2023
Job Address: 2875 LOKER AVE E, CARLSBAD, CA 92010-6626
Permit No:
Status:
Ccityof
Carlsbad
PREV2023-0013
Closed -Finaled
Permit Type: BLDG-Permit Revision Work Class: Commercial Permit Revision
Parcel#: 2090832100 Track#:
Valuation: $250,177.29 Lot#:
Occupancy Group: B
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition: 2019
Sprinkled: Yes
Project Title:
Project#:
Plan#:
Construction Type:V N
Orig. Plan Check#: CBC2022-0125
Plan Check #:
Description: ZEST DENTAL: DELTA 2 ELECTRICAL AND PLUMBING REVISIONS
Applicant:
SHANNON MCINTYRE
3911 SORRENTO VALLEY BLVD, # 120
SAN DIEGO, CA 92121-1457
(415) 432-6021
FEE
BUILDING PLAN CHECK FEE (manual)
BUILDING PLAN CHECK REVISION ADMIN FEE
Property Owner:
TECHBILT CONSTRUCTION CORPORATION
3575 KENYON ST, # SUITE 200
SAN DIEGO, CA 92110-5396
Total Fees: $155.00 Total Payments To Date: $155.00
Building Division
Applied: 02/10/2023
Issued: 04/12/2023
Finaled Close Out: 04/24/2023
Final Inspection:
INSPECTOR:
Contractor:
PACIFIC BUILDING GROUP
9752 ASPEN CREEK CT, # STE 150
SAN DIEGO, CA 92126-1082
(858) 552-0600
Balance Due:
AMOUNT
$120.00
$35.00
$0.00
Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-73 14 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
C cityof
Carlsbad
PLAN CHECK REVISION OR
DEFERRED SUBMITTAL
APPLICATION
B-15
Development Services
Building Division
1635 FaradayAvenue
442-339-2719
w ww.carlsbadca.gov
. . CBC2022-0125 2 Ong,nal Plan Check Number ________ Plan Revision Number _
ProjectAddress 2875 LOKER AVE. EAST, CARLSBAD, CA 92010
CONSTRUCTION CHANGE, REMOVAL OF ELECTRICAL EQUIPMENT General Scope of Revision/Deferred Submittal: __
CONTACT INFORMATION:
Name SHANNON MCINTYRE Phone 858-722-3292 Fax~---
Address 3911 SORRENTO VALLEY BLVD, SUITE 120 City SAN DIEGO Zip 921_2_1 __
Email Address SMCINTYRE@WAREMALCOMB.COM
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised: [i] Plans D Calculations D Soils D Energy D Other
2. 3.
D escribe revisions in detail List page(s) where each
revision is shown
ELECTRICAL EQUIPMENT REMOVED FROM SCOPE AND REMOVED FROM PLANS E301
NEW PLUMBING ADDED, COLD WATER PIPING AS CLOUDED P201
4. Does this revision, in any w ay, alter the exterior o f the project? D Yes [i] No
5. Does this revision add A NY new floor area(s)? D Yes [i] No
6. Does this revision affect any fire related issues? D Yes □ No
[i] No 7. Is this a complete set? ~Yes
~Signature _Sf__._~_IT,,__,__ ____ _ Date 12.06.2022
1635 Faraday Avenue. Carlsbad. CA 92008 Ph: 442-339-2719 Email: building@carlsbadca.gov
www.carlsbadca.gov