HomeMy WebLinkAbout2481 PALOMAR AIRPORT RD; ; AS010193; Permit6/2/22, 9:10 AM AS010193 Permit Data City of Carlsbad Sprinkler Permit 2481 PALOMAR Job Address: AIRPORT RD Permit Type: SPRINK Parcel No: Lot #: 0 Reference No.: PC #: Permit No: AS010193 Status: ISSUED Applied 10/1/2001 Approved: 10/17/2001 Issued: 10/17/2001 Inspector: Project Title: NORTH COUNTY ANIMAL SHELTER Applicant: Owner: Fees ($) Add'l Fees ($) Total ($) Balance ($) 300 0 300 0 1/1 C:\HASS73\FILES\NCOANIMl.SDF \ Abw lfr/"? RESID. FLOW AVAIL. TOTAL REQ'D PRESS. @ PRESS. @ DEMAND PRESS. (PSI) (GPM) (PSI) (GPM) (PSI) 75.0 (N/A) 75.0 46.6 708 DATE: 8/10/2001 JOB TITLE: NCOANIM1 WATER SUPPLY DATA SOURCE STATIC NODE PRESS. TAG (PSI) PRV (N/A) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 46.6 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 46.6 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (Fr) (PSI) (GPM) 1 7.0 K= 3.50 9.9 11.0 2 7.0 K= 3.50 10.1 11.1 3 7.0 K= 3.50 11.1 11.7 4 7.0 K= 3.50 13.2 12.7 5 7.0 - - - - 29.4 - - - 6 8.0 - - - - 34.0 TOR 8.0 - - - - 36.8 BOR 0.0 - - - - 42.8 Ui 0.0 - - - - 61.7 PRV 0.0 SOURCE 70.8 46.6 A &oio i9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 8/10/2001 C:\HASS73\FILES\NCOANIMl.SDF JOB TITLE: NCOANIM1 PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (Fr) SUM. NODES (Fr) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -11.0 1.049 PL 6.17 PF 0.3 1 7.0 3.5 9.9 11.0 4.1 120 FTG ---- PE 0.0 2 7.0 3.5 10.1 11.1 0.043 TL 6.17 PV 0.1 Pipe: 2 -22.1 1.049 PL 6.17 PF 1.0 2 7.0 3.5 10.1 11.1 8.2 120 FTG ---- PE 0.0 3 7.0 3.5 11.1 11,7 0.157 TL 6.17 PV 0.5 Pipe: 3 -33.8 1.049 PL 6.17 PF 2.1 3 7.0 3.5 11.1 11.7 12.6 120 FTG ---- PE 0.0 4 7.0 3.5 13.2 12.7 0.344 TL 6.17 PV 1.1 Pipe: 4 -46.5 1.049 PL 21.00 PF 16.1 4 7.0 3.5 13.2 12.7 17.3 120 FTG T PE 0.0 5 7.0 0.0 29.4 0.0 0.621 TL 26.00 PV 2.0 Pipe: 5 -46.5 1.380 PL 7.00 PF 5.1 5 7.0 0.0 29.4 0.0 10.0 120 FTG 6ET PE -0.4 6 8.0 0.0 34.0 0.0 0.163 TL 31.00 PV 0.7 Pipe: 6 -46.5 1.380 PL 11.00 PF 2.8 6 8.0 0.0 34.0 0.0 10.0 120 FTG T PE 0.0 TOR 8.0 0.0 36.8 0.0 0.163 TL 17.00 PV 0.7 Pipe: 7 -46.5 1.380 PL 8.00 PF 2.6 TOR 8.0 0.0 36.8 0.0 10.0 120 FTG CG PE 3.5 BOR 0.0 0.0 42.8 0.0 0.163 TL 16.00 PV 0.7 Pipe: S. -46.5 1.265 PL 100.00 PF 18.8 BOR 0.0 0.0 42.8 0.0 11.9 150 FTG E2T PE 0.0 Ui 0.0 0.0 61.7 0.0 0.165 TL 114.00 Pv 0.9 Pipe: 9 -46.6 1.265 PL 50.00 PF 9.2 Ui 0.0 0.0 61.7 0.0 11.9 150 FTG T PE 0.0 PRV 0.0 SRCE 70.8 (N/A) 0.165 TL 55.50 PV 1.0 NOTES: Calculations were performed by the HASS 7.3 computer program under license no. 2707013234 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.006 gpm and a maximum imbalance at any node of 0.055 gpm. Velocity pressures are printed for information only and are not used in balancing the system. Maximum water velocity is 17.3 ft/sec at pipe 4. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/10/2001 C:\HASS73\FILES\NCOANIMl.SDF JOB TITLE: NCOANIM1 (4) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEil chkvlv BfyVlv GatVlv AlmChk DPViv NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 10.00 5.00 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G N Eli Tee 45-Eli TeeRun couplg Swgchk GatVlv NPTee 1.265 3.00 5.50 1.00 0.50 0.50 5.50 0.50 5.50 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 8/10/2001 C:\HASS73\FILES\NCOANIMl.SDF JOB TITLE: NCOANIM1 WATER SUPPLY ANALYSIS Fixed Source Pressure: 75.00 psi 120.0 LEGEND I'll G 2 80.0 E 60.0 S S U R E 40.0 ( p S 20.0 -1..4.71 1 1 I 1 1 1 1 I I 20000400 500 600 700 800 900 1000 FLOW (GPM) Available pressure 75.00 psi @ 46.6 gpm Required pressure 70.82 psi @ 46.6 gpm SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 C:\HASS73\FILES\NCOANim2.SDF RESID. FLOW AVAIL. TOTAL REQ'D PRESS. @ PRESS. @ DEMAND PRESS. (PSI) (GPM) (PSI) (GPM) (PSI) 75.0 (N/A) 75.0 57.1 57.5 DATE: 8/10/2001 JOB TITLE: NCOANIM1 WATER SUPPLY DATA SOURCE STATIC NODE PRESS. TAG (PSI) PRV (N/A) AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 57.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 57.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (Fr) (PSI) (GPM) 1 9.0 K= 3.50 12.6 12.4 2 9.0 K= 3.50 13.2 12.7 3 9.0 K= 8.10 15.6 32.0 TOR 9.0 - - - - 23.0 BOR 0.0 - - - - 29.1 Ui 0.0 - - - - 39.4 PRV 0.0 SOURCE 57.5 57.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 8/10/2001 C:\HASS73\FILES\NCOANim2 .SDF JOB TITLE: NCOANIM1 PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -12.4 1.049 PL 12.00 PF 0.6 1 9.0 3.5 12.6 12.4 4.6 120 FTG ---- PE 0.0 2 9.0 3.5 13.2 12.7 0.054 TL 12.00 PV 0.1 Pipe: 2 -25.1 1.049 PL 12.00 PF 2.4 2 9.0 3.5 13.2 12.7 9.3 120 FTG ---- PE 0.0 3 9.0 8.1 15.6 32.0 0.199 TL 12.00 PV 0.6 Pipe: 3 -57.1 1.380 PL 22.00 PF 7.4 3 9.0 8.1 15.6 32.0 12.3 120 FTG ET PE 0.0 TOR 9.0 0.0 23.0 0.0 0.239 TL 31.00 PV 1.0 Pipe: 4 -57.1 1.380 PL 9.00 PF 2.1 TOR 9.0 0.0 23.0 0.0 12.3 120 FTG ---- PE 3.9 BOR 0.0 0.0 29.1 0.0 0.239 TL 9.00 PV 1.0 Pipe: 5 -57.1 1.394 PL 50.00 PF 10.4 BOR 0.0 0.0 29.1 0.0 12.0 150 FTG 2ET PE 0.0 Ui 0.0 0.0 39.4 0.0 0.150 TL 69.05 Pv 1.0 Pipe: 7 -57.1 1.265 PL 75.00 PF 18.1 Ui 0.0 0.0 39.4 0.0 14.6 150 FTG ---- PE 0.0 PRV 0.0 SRCE 57.5 (N/A) 0.241 TL 75.00 PV 1.4 NOTES: Calculations were performed by the HASS 7.3 computer program under license no. 2707013234 granted by HRS systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum • imbalance at any node of 0.005 gpm. (3) velocity pressures are printed for information only and are not used in balancing the system. Maximum water velocity is 14.6 ft/sec at pipe 7. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/10/2001 C:\HASS73\FILES\NCOANim2 .SDF JOB TITLE: NCOANIM1 (4) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: 540 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll chkvlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.394 3.15 6.30 2.10 7.35 6.30 1.05 10.50 10.50 6.30 PAGE: A MATERIAL: 540 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 10.00 5.00 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G N Eli Tee 45-Eli TeeRun Coupig SwgChk GatVlv NPTee 1.265 3.00 5.50 1.00 0.50 0.50 5.50 0.50 5.50 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 8/10/2001 C:\HASS73\FILES\NCOANim2 .SDF JOB TITLE: NCOANIM1 WATER SUPPLY ANALYSIS Fixed Source Pressure: 75.00 psi 120.( LEGEND Available pressure 75.00 psi @ 57.1 gpm G 2 Required pressure 80.0 57.52 psi @ 57.1 gpm P R E 60.0 2 S U R E 40.0 C p S 20.0 Wo -!4.71 1 I I I I 1 1 1 I 20000400 500 600 700 800 900 1000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 C:\HASS73\FILES\NCOANim3 .SDF (TE'1 3 RESID. FLOW PRESS. @ (PSI) (GPM) 115.0 1680.0 DATE: 8/13/2001 JOB TITLE: NCOANIM1 WATER SUPPLY DATA SOURCE STATIC NODE PRESS. TAG (PSI) SOR 120.0 AVAIL. TOTAL REQ'D PRESS. @ DEMAND PRESS. (PSI) (GPM) (PSI) 120.0 45.1 69.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 45.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 45.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (Fr) (PSI) (GPM) 1 9.0 K= 2.80 15.4 11.0 2 9.0 K= 2.80 15.9 11.2 3 9.0 K= 2.80 17.4 11.7 4 9.0 - - - - 17.0 5 9.0 K= 2.80 16.1 11.2 6 9.0 - - - - 61.3 TOR 9.0 - - - - 70.8 BOR 0.0 - - - - 77.3 U2 0.0 - - - - 80.8 SOR 30.0 SOURCE 69.5 45.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 8/13/2001 C:\HASS73\FILES\NCOANIM3.SDF JOB TITLE: NCOANIM1 PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (Fr) SUM. NODES (Fr) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -11.0 1.049 PL 10.00 PF 0.4 1 9.0 2.8 15.4 11.0 4.1 120 FTG ---- PE 0.0 2 9.0 2.8 15.9 11.2 0.043 TL 10.00 PV 0.1 Pipe: 2 -22.2 1.049 PL 5.00 PF 1.6 2 9.0 2.8 15.9 11.2 8.2 120 FTG T PE 0.0 3 9.0 2.8 17.4 11.7 0.157 TL 10.00 PV 0.5 Pipe: 3 -11.2 1.049 PL 5.00 PF 0.4 4 9.0 0.0 17.0 0.0 4.2 120 FIG T PE 0.0 3 9.0 2.8 17.4 11.7 0.045 TL 10.00 PV 0.1 Pipe: 4 11.2 1.049 PL 12.00 PF 0.9 4 9.0 0.0 17.0 0.0 4.2 120 FIG 2ET PE 0.0 5 9.0 2.8 16.1 11.2 0.045 TL 21.00 Pv 0.1 Pipe: 5 -45.1 1.049 PL 70.00 PF 43.9 3 9.0 28 17.4 11.7 16.7 120 FIG T PE 0.0 6 9.0 0.0 61.3 0.0 0.585 TL 75.00 PV 1.9 Pipe: 6 -45.1 1.380 PL 50.00 PF 9.5 6 9.0 0.0 61.3 0.0 9.7 120 FIG 2ET PE 0.0 TOR 9.0 0.0 70.8 0.0 0.154 TL 62.00 PV 0.6 Pipe: 7 -45.1 1.380 PL 9.00 PF 2.6 TOR 9.0 0.0 70.8 0.0 9.7 120 FIG CG PE 3.9 BOR 0.0 0.0 77.3 0.0 0.154 TL 17.00 PV 0.6 Pipe: 8 -45.1 1.265 PL 8.00 PF 3.5 BOR 0.0 0.0 77.3 0.0 11.5 150 FIG 3ET PE 0.0 U2 0.0 0.0 80.8 0.0 0.155 IL 22.50 Pv 0.9 Pipe: 9 -45.1 1.985 PL 50.00 PF 1.7 U2 0.0 0.0 80.8 0.0 4.7 150 FIG 5E2TC PE -13.0 SOR 30.0 SRCE 69.5 (N/A) 0.017 TL 96.00 PV 0.1 NOTES: Calculations were performed by the HASS 7.3 computer program under license no. 2707013234 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.008 gpm and a maximum imbalance at any node of 0.076 gpm. Velocity pressures are printed for information only and are not used in balancing the system. Maximum water velocity is 16.7 ft/sec at pipe 5. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 4 8/13/2001 C:\HASS73\FILES\NCOANim3.SDF F ITLE: NCOANIM1 PIPE FITTINGS TABLE Table Name: STANDARD.PIP A MATERIAL: 540 HWC: 120 eter Equivalent Fitting Lengths in Feet E T L C B G A 0 N Eli Tee LngEli chkviv BfyViv GatViv AimChk DPVlv NPTee 49 2.00 5.00 2.00 5.00 6.00 1.00 10.00 10.00 5.00 80 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 L MATERIAL: CT-L HWC: 150 ,.,ter Equivalent Fitting Lengths in Feet E T F R C S G N Eli Tee 45-Eli TeeRun Coupig Swgchk GatViv NPTee 65 3.00 5.50 1.00 0.50 0.50 5.50 0.50 5.50 85 5.50 9.00 2.00 0.50 0.50 9.00 0.50 9.00 ire 1 gpr - gpm ESCUTCHEON PLATE cSSU DEFLECTOR SEATING SURFACE 7/I6"(Il.lmm) PENDENT UPRIGHT CROSS SECTION 1 . Frame 3 - Gasketed 4 - Bulb 6 - Deflector 2 - Button spring 5 - Compression 7 - Bushing Plate Screw 8 - Pintle * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. - FIGURE A 3/8 INCH ORIFICE MODEL A PENDENT AND UPRIGHT SPRINKLERS 2-1/4" 1-9/16" (39.7mm) (572mm /2" NPT SSP DEFLECTOR* 2-3/ (55,6' I WRENCH LAT 7/16"(lt,tmm) MAKE-IN L 3 Asotot A®' PENDENT AND UPRIGHT SPRINKLERS UNIVERSAL MODEL A QUICK RESPONSE, 3mm BULB TYPE, 3/8" ORIFICE, 1/2" NPT 11 GENERAL DESCRIPTION The 3/8 inch orifice Universal Model A Pendent and Upright Sprinklers (Ref. Figure A) are automatic sprinklers of the frangible bulb type. They are "quick response - small orifice spray sprin- klers" intended for use in fire sprinkler systems designed in accordance with the standard installation rules recog- nized by the applicable Listing or Ap- proval agency (e.g., UL Listing is based on NFPA 13 requirements). These sprinklers, which are designed for use in Light Hazard Occupancies, have a discharge rate that is approxi- mately 50 percent of a standard nomi- nal 1/2 inch (15mm) sprinkler operat- ing at the same pressure. Both the Pendent and Upright Sprinklers pro- duce a hemispherical water distribu- tion pattern below the deflector. A pintle extending from the deflector boss identifies these 1/2 inch NPT Model A Sprinklers as having an orifice size other than standard nominal 1/2 inch (15mm), and the nominal orifice size of 3/8 is indicated on the deflec- tor. APPkflVAIS ANfl STANflARflS Laboratory listings and approvals for the 3/8 inch orifice Model A Pendent and Upright Sprinklers are given in Ta- ble A. WARNING The 3/8 inch orifice Model Pendent and Upright Sprinklers described herein must be installed and main- tamed in compliance rt.'ith this docu- ment, as well as applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities hai'ingjuris- diction. Failure to do so may impair the integrity of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. The installing contractor or manufacturer should be contacted relative to any questions. Installation 013/8 inch orifice Model A Pendent Sprinklers in recessed es- Printed in U.S.A. 6-98 cutcheons will void all sprinkler war- ranties, as well as possibly void the sprinkler's Approvals and/or List- ings. The 3/8 inch orifice Model A Pendent and Upright Sprinklers are rated for use at a maximum service pressure of 175 psi (12,1 bar) and they are avail- able in the temperature ratings and finishes indicated in Table A. The nominal discharge curve plotted in Figure B represents the flow "0" in GPM (LPM) as determined by the fol- lowing formula: K Fp where the nominal discharge coeffi- cient "K" equals 2.8 (40,4); and, "p' equals the residual flowing pressure in psi (bar). Listing standards permit the actual value of "K" to vary from 2.6 to 29 (37,5 to 41,8); however, for hy- draulic calculations, a K-factor of 2.8 (40,4) is to be applied. The Frame of the Model A Sprinkler (Ref. Figure A), is bronze per ASTM B176 (C87800) or, a proprietary alloy designated as OM. The Button (bulb retainer) is phospher bronze per ASTM B103 (051000 or C52100). The Gasketed Spring Plate consists of a Berylium Nickel (N03360) disc spring that is sealed on both its inside and outside faces with a Teflont gasket. The Compression Screw is bronze per ASTM B140 (C31400) and the Deflec- tons brass per ASTM B152 (C11000). The Bushing and Pintle are manga- nese bronze (067830) or leaded brass per ASTM B140 (032000). The Model A Sprinklers utilize a 3mm diameter frangible bulb. Table A indicates the bulb liquid color as a function of tem- perature rating. TD513M 45 x 40 Ui 35 0 1 cc 30 0. 25 0 IL 20 Ui IS 0, Ui DISCHARGE IN U.S. GALLONS PER MINUTE (GPM) so S IS IS 20 ------------- --------------4 - ------- -- ---- ---S -- —— -- .___ MM ==== mom --- --, - —.a mmmmm AwI I C 1,5 5. 3,0 2,5 C Z 2.0 C 0, 01 SPRINKLER FINISH TYPE TEMPERATURE BULB I NATURAL CHROME POLYESTER RATING LIQUID BRASS I PLATED COATED COLOR I I (All Colors) 135°F/57°C Orange PENDENT 155°F/68°C Red and UPRIGHT 1 2 3 4 175°F/79°C Yellow 200°F/93°C 286°F/141°C Mauve 1,2,4 NOTES: Listed by Underwriters Laboratories, Inc. as Quick Response Sprinklers for use in Light Hazard Occupancies.. Listed by Underwriters Laboratories of Canada as Quick Response Sprinklers for use in Light Hazard Occupancies.. Approved by Factory Mutual Research Corporation as Quick Response for use in Light Hazard Occupancies. Accepted by the City of New York under MEA 241-94-E. TABLE A LABORATORY LISTINGS AND APPROVALS NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontal, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6mm) for the 135°F/57°C to 3/32 inch (2,4mm) for the 286°F! 141°C rating (At higher ambi- ent temperatures, the bubble may be barely perceptable for the lower tem- perature ratings.) Installation of 3/8 inch orifice Model A Pendent Sprinklers in recessed es- cutcheons will void all sprinkler war- ranties, as well as possibly void the sprinkler's Approvals and/or List- ings. The Model A Pendent and Upright Sprinklers must be installed in accord- ance with the following instructions. Prior to installing pendent sprinklers and if applicable, verify that the face of the sprinkler fitting is within the proper range of distance which can be accommodated by the type of escutcheon being used. With pipe thread sealant applied to the pipe threads, install the escutch- eon, as applicable, over the sprinkler threads. Hand tighten the sprinkler into the sprinkler fitting. Refer to Figure C and select the appropriate Sprinkler Wrench for tightening the sprinkler into the sprinkler fitting. The F850 Sprinkler Wrench must be used for installing polyester coated sprinklers, in order to prevent dam- age to the sprinkler finish. NOTES A leak tight 1/2 inch NPT sprin- kler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of2l ft. lbs. (28,5 Arm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to make-up for in- sufficient adjustment in the es- cutcheon plate by under- or over- tightening the sprinkler Readjust the position of the sprinkler fitting to suit. CARE AND JMAINTENANCE Automatic sprinklers must never be shipped or stored where their tempera- tures will exceed 100°F/380C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of com- bustion, but have not operated, should be replaced if they cannot be com- pletely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - both before and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost - 39 45 50 00 70 DISCHARGE IN LITRES PER MINUTE FIGURE B NOMINAL DISCHARGE CURVE liquid from its bulb (ref. Installation Section Note). NOTES Absence of an escutcheon, which is used to corer a clearance hole, mciv delay the time to sprinkler operation in a fire situation. Before closr.g a fire protection system control uale for maintenance work on the fire protection system which it con trols, permission to shut down the af- fected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. It is recommended that automatic sprinkler systems be inspected quar- terly by a qualified Inspection Service. t DuPont Registered Trademark USE: When using an 8 or 10 inch adjustable Crescent type wrench, the wrench is to be applied to the sprinkler wrench flats only (Ref. Figure A). To use the F850 Sprinkler Wrench, slip the Wrench opening over the Model A Sprinkler Deflector by passing the Sprinkler Wrench around the side of the Sprinkler as shown in the above illustration. Using a 1/2 inch ratchet drive or by applying an 8 or 10 inch adjustable wrench to the hex end of the Sprinkler Wrench, tighten the sprinkler into the fitting. The two tugs located on opposite sides of the Wrench indicate the orientation of the sprinkler frame arms. NOTE Push up on the Sprinkler Wrench, while it is being turned, to ensure that the Wrench recess stays fully engaged with the sprinkler wrench flats. Carefully remove the Sprinkler Wrenëh by disengaging it from the sprinkler wrench flats, and then passing it sideways over the sprinkler deflector. FIGURE C SPRINKLER WRENCH SELECTION AND USE Seller warrants for a period of one year from the date of shipment (warranty r''- .,,rL, LlLII4u hereunder will rr be free from defects in material and workmanship. For further details on Warranty, see Price List. A Product Symbol Number (PSN) is not specified when ordering polyester coated Model A Sprinklers with other than a white color. It is suggested that a color chip be provided when ordering special color finishes. Otherwise, re- sponsibility for duplication cannot be accepted. Contact your local distributor for avail- ability. Sprinkler Assemblies: Specify: 3/8 orifice, (specify tempera- ture rating), Model A (specify Pendent or Upright) Sprinkler with (specify type of finish), PSN (specify from Table B). Sprinkler Wrench: Specify: Model F850 Sprinkler Wrench, PSN 56-850-4-001. The nominal weights are as follows. 318 Orifice Model.A Pendent Sprinkler ........2.4 ozs. (68 g) 3/8" Orifice Model A Upright Sprinkler .........2.6 ozs. (75 g) Model F850 Sprinkler Wrench .........15.5 ozs. (440 g) a SELECTION: Select the appropriate wrench -, c on on th n fnl!n,,rna roar,; ro. ments: rat brass or chrome plated fin- ish may be be installed using an 8 or 10 inch adjustable Cres- cent type wrench or the Model 20 F850 Sprinkler Wrench. B. Model A Sprinklers with a poly- ester coated finish must only be installed with the Model F850 Sprinkler Wrench. Model F850 Nylon Coated Sprinkler Wrench PSN 57 - XXX - X - XXX TEMPERATURE RATING 135 I 135F/57°C SPRINKLER FINISH 155 I 155°F/68°C TYPE 1 I NATURAL BRASS 175 I 175°F179°C 331 I OR PENDENT 4 WHITE POLYESTER 200 200F/93°C 330 I OR UPRIGHT 9 CHROME PLATED 286 286°F/141°C TABLE B PRODUCT SYMBOL NUMBER SELECTION 3/8 INCH ORIFICE MODEL A PENDENT AND UPRIGHT SPRINKLERS WITH 1/2 INCH NPT CONNECTION Components: 1 - Frame 4 - Bulb 7 - Bushing 2 - Button Assembly 5 - Compression Screw 8 - Ejection Spring 3 - Gasketed Spring Plate 6 - Deflector CENTERLINE OF SPRINKLER WATERWAY FIGURE A 3.5 K-FACTOR MODEL F685 (SIN G1685) RESIDENTIAL HORIZONTAL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS eoss . 1-1/2" 7/16- (38,1 mm) (11.1 mm) MAKE-IN 3/4 2-3/16- _0 mm) (55,6 mm) 5/15' (7,0 mm: 2-7/5" (73,0 mm) I /2" NPT ESCUTCHEON NC A HOR. & REC. HOR. SIDEWALL SPRINKLERS, RESIDENTIAL MODEL F685 DESIGNER, BULB TYPE, 3,5 K-FACTOR, 155°F & 17 01= -- They are designed for installation along a wall or lintel and just beneath a smooth and level ceiling. Horizontal sidewall sprinklers are generally used in lieu of pendent or upright sprinklers because of aesthetic, building con- struction, or installation economy con- siderations. The recessed versions of the Model F685 Sprinkler are obtained by utiliz- ing the Model. F705Recessed Es- cutcheon (Ref. Figures A and B-2). The F705 Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush sidewall position. The F705 has a separable two-piece design which allows installation of the sprinklers and pressure testing of the fire protection system, prior to wall construction and/or application of a fin- ish coat to the wall. They also permit refinishing of a wall surface without having to first shut down the fire pro- tection system and remove the sprin- klers. The F685 Sprinklers have been de- signed to operate with a particular temperature rating and heat respon- sive thermal characteristic, as well as • to discharge water in a specific pattern and quantity per square foot relation- ship. The combination of the perform- ance characteristics which are associ- ated with the F685 Sprinklers have The 3.5 K-factor, Model F685 Designer Residential Horizontal and Recessed Horizontal Sidewall Sprinklers (Ref. Figure A) are automatic sprinklers of the frangible bulb type. They are to be used in wet pipe residential sprinkler sys- tems for one- and two-family dwell- ings and mobile homes per NFPA 13D, wet pipe residential sprinkler sys- tems for residential occupancies up to four stories in height per NFPA 13R, and wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. Printed in U.S.A. 10-00 TD587F MINIMUM MINIMUM SINGLE MULTIPLE SPRINKLER SPRINKLER W x L'' IMF FLOW' &LUW' A B APPLICATION FT x FT oF GPM (psi) GPM (psi) INCHES FEET RES(a) 12 x 12 155 12 (118)(Q) 11 (9.9)(d)4 to 10) 6 RES(a) 12x 12 175 13(13 .8)(d) 11 (99)(d) 4t0 12 6 RES(a) 14 x 14 155 13 (138)(d) 12 (11,8)(d) 4 to 12 7 RES(a) 14 x 14 175 14 (16.0)(d) 12 (11.8)(d) 4 to 7 RES(a) 16 x 16 155 16 (209)(d) 14 (160)(d) 4 to 6° 8 RES(a) 16 x 16 175 16 (209)(d) 14 (160)(d) 4 to 6(e) 8 -CENTERLINE OF c SPRINKLER WATERWAY NO D-I4 FEET __.1__H C-S FEET LIMIT . MINIMUM L I MINIMUM --- - S - - - - LIMITS OF SINGLE -... I -- *DEFLECTOR_TO_ SPRINKLER COVERAGE -.. CEILING DISTANCE AREA .2"-.. NOTES: (i\ W& ri-, 4i -.-"-'---- resiaentiai portions of any occupancy per NFPA 13 (see Note d), in one- and two- family dwellinns And mobile homes per NFPA 13D, or residential occupan- cies per NFPA 13R. For coverage area dimensions less than or between those indicated, it is neces- sary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM from each sprinkler. The indi- cated residual pressures are based on the nominal K-factor. Refer to Hydraulic Design Criteria under Residential Design Criteria Section for details including NFPA 13 minimum de- sign densities. To meet this requirement, the centerline of the waterway (Ref. Fig. A) must be installed between 4-5/16 and 6-5/16 inches below the ceiling. To meet this requirement, the centerline of the waterway (Ref. Fig. A) must be installed between 4-5/16 and 12-5/16 inches below the ceiling. TABLE A NFPA 13D AND NFPA 13R 0 HYDRAULIC DESIGN CRITERIA FOR THE 3.5 K-FACTOR MODEL F685 RESIDENTIAL HORIZONTAL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS been proven to help in the control of residential type fires and, therefore, to improve the chance for occupants to escape or be evacuated. Fire sprinkler systems are not a substi- tute for intelligent fire safety aware- ness or construction materials and practices required by building codes. The 3.5 K-factor, Model F685 Designer Residential Horizontal and Recessed Horizontal Sidewall Sprinklers are listed by Underwriters Laboratories Inc. and Underwriters' Laboratories of Canada. The listings only apply to the sprinkler finishes and service condi- tions indicated in the General Techni- cal Data and Residential Design Crite- ria sections. The 35 K-factor, Model F685 Designer Residential Horizontal and Recessed Horizontal Sidewall Sprinklers are also approved by the Scientific Services Laboratory (Australia), as well as ac- cepted by the City of New York under MEA 39-92-M. Any questions concerning an interpre- tation of NFPA 13, 13D, or 13R sprin- kler system design/installation stand- ards, as well as requests for system design/installation standards not pres- ently covered by NFPA 13, 13D, or 13R, should be addressed to the: Secretary, Standards Council National Fire Protection Association Batterymarch Park Quincy, MA 02269 WARNINGS The Model F685 Residential Hori- zontal and Recessed Horizontal Sidewall Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the Na- tional Fire Protection Associa- tion, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integrity of these de- vices. Because of the above cited stipu- lations and the varied nature of residential type architecture, there may be some compartment. designs which cannot be fully sprinklered in accordance with the recommendations of NFPA 13, 13D, or 13R. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. It is the responsibility of an in- stalling contractor to provide a copy of this document to the owner or his representative and, in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner; The owner is responsible for maintaining their fire protection system and devices in proper op- erating condition. The installing contractor or sprinkler manufac- turer should be contacted relative to any questions. —2— CEILING - - C 1/6 (3,L mm) DEFLECTOR—TO FACE OF SPRINKLER FITTING — CEILING DISTANCE PER TABLE .: mm) DEFLECTOR 2-1/4' mm) DIA. CENTERLINE i-'--- B OF SPRINKLER WATERWAY MODEL P705 RECESSED ESCUTCHEON 2-7/8" (73,0 mm) DIA. WALL OR SOFFIT I MOUNTING SURFACE ---_-,. - - - - - -, - - - - - - - - - I I / 4" (101.6 mm) : :i MAXIMUM FOR MAXIMUM FOR _ SOFFIT MOUNT SOFFIT MOUNT FIGURE B-2 MODEL F685 RECESSED HORIZONTAL SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE MODEL F705 RECESSED ESCUTCHEON -"'i 3— a /4 CEILING STANDARD 14.44 I ESCUTCHEON DEFLECTOR—TO— PLATE CEILING 01$ ANOL PER TABLE A DEFLECTOR PP 5/16w (7,9 mm) LjLlN., II'.CL) ESCUTCHEON PLATE PER TABLE A DEFLECTOR LECTOR HF (75j 16Y•4_== MAXIMUM SPRINKLER FiTT 0 CENTERLINE OF SPRINKLER WATERWAY SPRINKLER CENTERLINE OF SPRINKLER WATERWAY 1-1/2 to 6 INCHES (38,; to 152,4 mm) 1-1/2 to 3 INCHES (38.1 to 76.2 mm) 0~~ I / A 8 (203.2 mm) MAXIMUM - WALL MOUNTING - - SOFFIT MOUNTING - FIGURE B-i TYPICAL INSTALLATION USING A STANDARD ESCUTCHEON FULLY RECESSED DIM ENSIONSt Up to 1/4 inch adjustment from minimum 1/4 inch to maximum 1/2 inch recessed position. Dim. Inches MM A- 1/2tt 12,7 B-Mm. 1 25,4 B-Nom. 1-1/8 28,6 B-Max. 1-1/4 31,8 C-Min. 1/4 6,4 C-Max. 1/2 12,7 HIGH ADJUSTMENT DIMENSIONS Up to 1/2 inch adjustment from the flush sidewall position to 1/2 inch recessed position. Dim. Inches MM A- 3/8±1/8tt 9,5±3,2 B-Mm. 1 25,4 B-Nom. 1-1/4 31,8 B-Max. 1-1/2 38,1 C-Mm. FLUSH - C-Max. 1/2 12,7 t For best overall appearance. tt Remaining 1/4 inch (6,4 mm) of adjust- ment can be used to compensate for variations in sprinkler make-in and fit- ting take-out. Figure B-i illustrates a typical installa- tion of an F685 Sprinkler using a standard one-piece escutcheon plate like that described in Technical Data 2 Sheet TD805. Refer to Technical Data. She-et TD805 for information on other available flush mount escutcheons. 'Its 1441fl4 .. fl.J.J.4&slE.J. The .3 5 K-ftor Model F685 Designer Residential Horizontal Sidewall Sprin- klers are availabie in 1bbFI68C and 1 75°F179°C temperature ratings and they are rated for use at a maximum service pressure of 175 psi. They are available chrome plated, natural brass, or polyester coated in any color. The nominal flow '0' in GPM (LPM) is determined by the following formula: 0 = K (ph2) where the nominal sprinkler discharge coefficient "K" equals 3.5 (50,4) and "p" equals residual pressure in psi (bar). The F685 utilizes a 3 mm Bulb with a dezincification resistant bronze alloy Frame. The Button (bulb retainer) is phosphor bronze per ASTM B103 (C51000, 052000. or C54000), and the Bushing is brass per ASTM B152 (032200). The Gasketed Spring Plate consists of a Beryllium Nickel (N03360) disc spring that is sealed on both its inside and outside edges with a Teflont gasket. The Ejection Spring is stainless steel, the Compression Screw is plated bronze per ASTM B140 (C31400). and the Deflector is brass per ASTM B36 (022000). Escutcheon Plates: A separately ordered escutcheon plate is required for concealed piping instal- lations. Figure 6-2 illustrates the Model F705 Recessed Escutcheon which is the only recessed escutcheon acceptable for use with the Model F685 Horizontal Sidewall Sprinkler. It has a Closure and Mounting Plate fabricated from low carbon steel. The Mounting Plate prongs, which are compressed back into the Mounting Plate as the Closure is pushed over it. maintain a tight fric- tion fit between the two pieces. The Mounting Plate and Closure can also swivel relative to each other and com- pensate for minor non-perpendicular- ity between the Model F685 Sprinkler and the wall. The F705 Escutcheons are available with a chrome plated finish or a coated finish in any color. NOTES Absence of an escutcheon may de- lay the time to sprinkler opera- tion in a fire situation. Only use escutcheons which con- sist of metallic materials that will not deform or dislodge at a uqJI uuI 1200°F/649°C and/or which have been listed by Underwriters Labo- ratories Inc. for fire protection service. The escutcheon plates like those shown in Technical Data Sheet TD805, as well as the F705 Es- cutcheon, cannot be used to hold the F685 in position. The F685 must be secured in position by firmly fastening the sprinkler sys- tem piping to the dwelling struc- ture. If the F685 is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orienta- tion and water distribution pat- tern. The 3.5 K-factor, Model F685 Designer Residential Horizontal and Recessed Horizontal Sidewall Sprinklers must only be installed and utilized in accord- ance with the following described cri- teria which are provided by the manu- facturer. NOTES Residential Fire Sprinkler Sys- tems should only be designed and installed by those compe- tent and completely familiar with automatic sprinkler sys- tem design,, installation pro- cedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer re- view and develop a working un- derstanding of the complete list of criteria, prior to initiat- ing the design of the sprinkler system. Questions concerning sprink- ler installation and usage cri- teria, which are not covered by the following instructions, should be mailed to the atten- tion of the Technical Data De- partment. Include sketches and technical details, as ap- propriate. In some instances, the require- merits of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, NFPA 13D, NFPA 13R, or by the authority having jurisdiction. General Service Conditions. The F685 Sprinklers must only be utilized in wet pipe sprinkler systems with all RC SUi II L,LI .)y .LCII as the sprinklers maintained at a mini- mum temperature of 40°F/40C. Hydraulic Design Criteria. The mini- mum required single and multiple sprinkler flow rates for systems de- signed to NFPA 13D or NFPA 13R are given in Table A as a function of tem- perature rating and the maximum al- lowable coverage areas. The single sprinkler flow rate is the minimum re- quired discharge from the most hy- draulically demanding single sprinkler and, the multiple sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R). The minimum required discharge from each of the "design sprinklers" for sys- tems designed to NFPA 13 must be calculated based on delivering a mini- mum design density of 0.1 gpm per sq. ft. for each of the listed coverage areas shown in Table A. NOTE The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R), must be kept as few as possible. Do NOT use more sprinklers than neces- sary to cover a particular space. Spray Coverage Criteria. Each F685 Sprinkler must only be used in accord- ance with one of the designated width by length (W x L) coverage criteria specified in Table A. Ceiling mounted obstructions such as heating or air conditioning diffusers, overhangs, and light fixtures must be located above an elevation, as shown in Figure C, where they will not inter- fere with the proper distribution of water by the sprinkler. F685 Sprinklers may be installed along overhangs or soffits that are a maxi- mum of 8 inches wide (distance from wall); with a maximum vertical dis- tance of 4 inches from the centerline of the sprinkler waterway to the bottom of the overhang soffit; and, with a de- flector-to-soffit surface distance of 1-1/2 to 3 inches when using a flush mount escutcheon as shown in Figure B-i, or with the Model F705 Escutch- eon as shown in Figure B-2. NOTE Use of overhangs or soffits with dimensions exceeding the above specified criteria is permitted if additional sprinkler protection is provided for the area below the overhang/soffit. 0 —4— t DuPont Registered Trademark SIDEWALL _Fff O,l +4' o'\ 2 SPRINKLER NOTES: I...LI'Ll\LII'1. yr #rEA PLAN VEW For a given position within the coverage area, ceiling mounted obstructions must not hang below the elevation dimension given in the graph. Elevation dimensions are with respect to the top of the Deflector Hat (Ref. Figure A), where positive (+) dimensions are above the Deflector Hat and negative (-) dimen- sions are below. (Reference: the Deflector Hat is 5/16" above the sprinkler centerline of waterway.) FIGURE C ALLOWABLE ELEVATION FOR CEILING MOUNTED OBSTRUCTIONS SUCH AS HEATING OR AIR CONDITIONING DIFFUSERS, OVERHANGS AND LIGHT FIXTURES The F685 Sprinklers must NOT be lo- cated along a wall/partition having an ad- joining wood or coal burning stove, or - - along a wall/partition containing a fireplace or wall oven. NOTE The spray from the F685 is dis- tributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will not be any blind spaces shielded from spray by partitions, room di- viders, overhangs or other parts of the dwelling structure. Operational Sensitivity Criteria. The F685 Sprinklers must only be installed beneath level ceilings, beneath solid ceilings having a smooth or textured surface, with a deflector-to-wall surface dis- tance of 1-1/2 to 6 inches or a deflec- tor-to soffit surface distance of 1-1/2 to 3 inches when using a flush mount mount escutcheon as shown in Fig- ure B-i, unless the Model F705 Re- cessed Escutcheon is being utilized as shown in Figure B-2. with a deflector-to-ceiling distance per Table A, and at least 4 inches away from an inside or outside corner. The F685 Sprinklers must NOT be used beneath soffits or overhangs, unless they are only providing protection for the area underneath the soffit/over- hang and additional sprinkler protec- tion is provided for the area in front of the soffit/overhang, above or below open-gridded type suspended ceilings, or with beams, joists, or ducts located within the sprinkler coverage areas. NOTE Where utilized, beams, joists, or ducts must be located with their centerlines along the boundaries separating adjacent sprinkler coverage areas. It is recommended that as part of the sprinkler system design, the designer review the dwelling plans and, where appropriate, advise the owner or his representative as to the following. I. Lintels of at least 3 inctes'l.rielght and preferably 8 Incheshould be used overall passageways from one space to another, in order to reduce the or &hilify rf r,rpklr nnerptjCinS outsae o[ we we area. II, Beams of at least 3 inches of heinht should be used to border each of 3 or more adjoining areas of F685 Sprinkler coverage (within the same to daoa::: the time to first sprinkler operation as well as to reduce the possibility of multiple sprinkler operations. Cold Soldering Criteria. With refer- ence to Table A, the F685 Sprinklers must be located such that the minimum lateral distance "C" be- tween adjacent sprinklers is 8 feet, and the minimum distance "D" between sprinklers located opposite or with their waterway centerlines at 900 to each other is 14 feet, except where a portion of the dwelling structure or a partition will shield the spray of one sprinkler from the other. Heat Source Criteria. Refer to NFPA 13D and NFPA 13R for the require- ments relating to preventing the possi- ble release of an F685 heat responsive element (Bulb), due to exposure to heat sources other than abnormal fire. O 1. along a wall/partition having a re- cessed range oven, countertop, or alcove, NOTES r V:.... Q....LV,.... 0..... '"'.4'.' ._ .-_.t. • tems should only be designed and installed by those competent and cuinpi*.ity JaIIiiUI with auto- matic sprinkler system design, in- stallation procedures, and tech- niques. The Technical Data Department should be contacted relative to any questions. Do not install any bulb type sprin- kler if the bulb is cracked or if there is a loss of liquid from the bulb. With the sprinkler held horizontal, a small air bubble with an approximate diameter of 1/16 inch should be be present. The Model F685 Designer Residential Sprinklers must be installed in accord- ance with the following instructions: WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE D W-TYPE 7 SPRINKLER WRENCH 4. Wrench tighten the sprinkler using only the W-Type 7 Sprinkler Wrench (Ref. Figure D). The wrench recess of the W-Type 7 is to be applied to the sprinkler wrench flats (Ref. Fig- ure A). The word "TOP" on the De- flector must face upwards towards the ceiling. SPRINKLER SPIRIT 1ff_ LEVEL FITTING n. CENTERLINE OF SPRINKLER WATERWAY to ' 6 INCH (150 mm) O LONGER PIPE NIPPLE cPIPIT rWL Lt.L &-cc,~-D A '/L PRINKLER gu FIGURE E LEVELING OF SPRINKLER FITTING AND DEFLECTOR 1. The F685 Sprinkler must be installed with the centerline of the waterway horizontal and perpendicular to the backwall surface. NOTE It is recommended that a spirit level be used to level the sprin- kler fitting as shown in Figure E and that a square be used to check perpendicularity of the waterway centerline to the mounting surface. Prior to installing each Sprinkler, verify that the outer face of the mat- ing fitting is within the proper range of distance of the mounting surface, which can be accommodated by the particular type of escutcheon plate being used. When installing a Model F685 Pen- dent Sprinkler with the F705 Re- cessed Escutcheon, for best overall appearance, use Dimension "A" in- dicated under the "Fully Recessed Dimensions" heading of Figure B-2. Otherwise, use Dimension "A" under the "High Adjustment Dimensions" heading. In either case, the remain- ing adjustment can be used to com- pensate for the possible manufac- turing variations in the take-out of the fitting, as well as in the make-in of the sprinklers (as permitted by ANSI 131.20.1). 3. After installing the F705 Mounting Plate (or other escutcheon, as appli- cable) over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. NOTES A leak tight 1/2 inch NPT sprin- kler joint should be obtained with a torque of 7to 14ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft.lbs. (28,5 Nm) oftorque is to be used to install sprinklers. Higher levels of torque may dis- tort the sprinkler orifice seat with consequent leakage. It is recommended that a spirit level be used to level the Deflec- tor, as shown in Figure E. The Deflector slopes slightly upward from back to front; conse- quently, the level needs to bepo- sitioned along the front edge of the Deflector. Do not attempt to make-up for insufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. 5. In recessed horizontal sprinkler in- stallations, after the wall has been installed or the finish coat has been applied, slide on the F705 Closure over the Model F685 Sprinkler and push the Closure over the Mounting Plate until its flange comes in con- tact with the wall. in bursting of the pipe and/or sprinkler. Do NOT enclose sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Automatic sprinklers are NOT to be tested with a heat source. Op- eration of the heat responsive element (Bulb) can result. Do NOT cleanse the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Within the sprinkler coverage area, the minimum vertical clear- ance between the tops of free standing partitions, room divid- ers, cabinets, storage racks, stock piles, etc., and the sprinkler de- flector is NOT to be less than the clearance given below. Horizontal Distance Vertical from Sprinkler Clearance to Item, ft. In. More than 9 ........32 Between 6 and 9 .....26 Less than.6 ........ 18 Exercise suitable safety precau- tions in the use and storage of highly flammable and potentially explosive materials. The rapid rate of fire .development and spread which can be caused by such materials can reduce the ability of the sprinkler system to aid in the control of a fire in which they are involved. —7— vvnen remooeiing, sucn as oy aaaing false beams or light fixtures or Chang- inn thp location of r.omrtrtment walls. first verify that the new construction will not violate the installation require- the new construction and/or the sprin- kler system to suit the requirements of this document. IN n. PRA(PflIJRF - A Product Symbol Number (PSN) is not specified when ordering polyester coated Model F685 Sprinklers with other than a white color or when order- ing color coated F705 Recessed Es- cutcheons with other than white color. It is suggested that a color chip be provided when ordering special color finishes. Otherwise, responsibility for duplication cannot be accepted. Contact your local distributor for avail- ability. Sprinkler Assembly: Specify: (specify temperature rating) Model F685 Designer Residential Horizontal Sidewall Sprinkler with (specify type) finish, PSN (specify). Chrome Plated Finish 155"F/68°c ...............PSN 51-685-9-155 Natural Brass Finish 155'F/68'C ...............PSN 51-685-1-155 White Polyester Finish 155F/68°C ...............PSN 51-685-4-155 Chrome Plated Finish 175'F79'C ...............PSN 51-685-9.175 Natural Brass Finish 175°F/79°C ......... ........PSN 51-685-1-175 White Polyester Finish 175'F;79C ...............PSN 51-685-4-175 Recessed Escutcheon: Specify: 1.2 (15 mm) Model F705 Re- cessed Escutcheon with (specify fin- ish), PSN (specify). 1/2' 05 mm Chrome P a:c .........PSN 56-705-9-010 1/2 (15 mm; While color Coated ................PSN 56-705-4.010 Sprinkler Wrench: Specify: W-Type 7 Sprinkler Wrench, PSN 56-850-4-001. Order for NFPA publications should be addressed to the: Publication Sales Department NFPA Batterymarch Park Quincy, MA 02269 The nominal weight of the Model F685 Designer Residential Horizontal Side- wall Sprinkler is 2.6 ounces. Tile F6x5 .Spiiuukiers fflUS( never .oe .shipped or stored where their tempera- ture will exceed 100°F/38°C and they must never be painted, plated, coated, or otherwise altered after leaving the elaiII..La I4I4J.J& II.# placed. Sprinklers that have been ex- posed to corrosive products of com- bustion, but have not operated, should be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. NOTE Particular care to prevent over- heating must be exercised when storing sprinklers in cars, trucks, trains, or other vehicles on warm, bright sunny days. Care must be exercised to avoid dam- age to the F685 Sprinklers - both be- fore and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion Section). NOTES Absence of an Escutcheon Plate, which is used to cover a clearance hole, may delay the time to sprin- kler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire pro- tection system which it controls, permission to shut down the af- fected fire protection systems must be obtained from the proper authorities and alipersonnel who may be affected by this action must be notified. It is recommended that automatic sprinkler systems be inspected and maintained in accordance with the advice and suggestions given in NFPA 25. It is recommended that automatic sprinkler systems be inspected quar- terly by a qualified Inspection Service. The F685 Sprinklers must only be re- placed with horizontal sidewall sprin- klers which are listed for residential fire protection service and which have the same nominal K-factor, the same cov- erage area, and the same or lower flow ratings (as indicated under "Hydraulic Design Criteria").. S NOTES Wet pipe sprinkler systems must be maintained at a minimum tem- perature of 40°F/4°C. Exposure to freezing temperatures can result LIMITED WARRANTY The manufacturer warrants for a period of one year from the date of sale (warranty period) that the product(s) sold hereunder are free from defects in material and workmanship. Our obligation under this warranty is limited to repair or replace- ment, or, at our option, we will repay the price paid for the product(s), plus any trnnrrttfr)n nhsrnp. rfrj hv thp. ntirr.hsr In thp. r.qqq rf rnIrmnt m1p, will pay the transportation charges to the location of the defective product. We must be given the opportunity to inspect any product you believe to be defective. To make a claim under this limited warranty, you should contact our Sales Services Manager at (401) 781-9032. THERE ARE NO OTHER WRITTEN OR ORAL WARRANTIES. ALL IMPLIED WMHHMN I Ib or liIHL.t1MI\d IMbILI I Y Ml\fL) f-I I Ntb f-OH A IAH I IULAH PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THE LIMITED WARRANTY SET FORTH ABOVE. The manufacturer does not assume any other obligation in connection with the sale of the product(s) by purchaser. This warranty shall not apply to any product(s) which have been installed in violation of written instructions furnished by the manufacturer, repaired or altered, misused or damaged, or not properly maintained. The manufacturer is not liable for indirect, incidental or consequential damages in connection with the use of the product(s). Some states do not allow limitations on how long an implied warranty lasts, or exclusion or limitation of incidental or consequential damages, so the above limitations or exclusion may not apply to you. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. (a tqCo/F/owContd-oi/ G.m GEM SPRINKLER COMPANY, 323 East 151st Street, Harvey, IL 60426 Sprinki.r Toil-free (877) 436-8926 / Fax (708) 331-9605/ www.gemsprinkIer.com 1 - Frame 2 - Button 3- Gaskeled - Spring Plate 4 -Bulb 5 - compression Screw 6 - Deflector Temperature rating is indicated on deflector or adjacent to orifice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE A 17/32 INCH ORIFICE MODEL A EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS T0547 7/16" 11,1mm) 1-1/2" WALL PLATE 38,1 mm) SEATING SURFACE 9/16" 2-1/4" (14,3 mm) (57,-2 mm) MODEL F700 or F705 RECESSED ESCUTCHEON no HOR. SIDEWALL & RECESSED HOR. SIDEWALL SPRINKLERS UNIVERSAL MODEL QR-EC nnd EC-,3 & 5 n\n, B ULB TYPF, 132' (7fl mm) ORIFICE, 3/411 MDT** The 17/32 inch (20 mm) orifice Univer- sal Model A Extended Coverage Hori- zontal Sidewall Sprinklers and Re- cessed Extended Coverage Horizontal Sidewall Sprinklers (Ref. Figure A) are automatic sprinklers of the frangible bulb type. They are available in the following temperature ratings and model designations: 135F/57C Model A QR-EC 135F/57C Model A EC 155'F/68C Model A OR-EC/EC 155F/68C Model A EC 175F/79'C Model A QR-EC/EC All QR-EC and QR-EC!EC models uti- lize a 3 mm diameter bulb, and all EC models utilize a 5 mm diameter bulb. 4 (5mm) CENTERLINE OF WATERWAY 1/2(12,7mm) MAKE-IN 3/4"NPT WRENCH FLAT The model designation suffix (i.e., . OR-EC or EC) indicates the intended aoolication. as aiven in Table A-i or A-2, for use in light hazard, quick response - ex- tended coverage (QR-EC) sprinkler system applications per NFPA 13 or FM installation standards, or light hazard, extended coverage (EC) sprinkler system applications per NFPA 13 or FM installation stan- dards. They are designed for installation along a wall and just beneath a smooth and level ceiling as defined in the ap- plicable installation standard. Horizon- tal sidewall sprinklers are generally used in lieu of pendent sprinklers be- cause of aesthetic, building construc- tion, or installation economy consider- ations. The recessed versions of the Model A Extended Coverage Horizontal Side- wall Sprinklers are obtained by utiliz- ing either the Model F700 or F705 Re- cessed Escutcheon (Ref. Figure B). The Recessed Escutcheons have a separable two-piece design which al- lows installation of the sprinklers and • pressure testing of the fire protection system, prior to wall construction and/or application of a finish coat to the wall. They also permit refinishing of a wall surface without having to first Printed in U.S.A. 12-96 COVERAGE AREA.MINIMUM APPLICATION W x L FT y FT. (my rn'l FLOWC) (PM (I PM MINIMUM PRES. PS! (P.AP) DEFLECTOR-TO- CE A'' !I('MS (mm\ SPRINKLER MODEL BULB TEMP. RATING SIZE (Pnfl 1S;< 15 (4,3 x 25 (32) 12.3 (071) 1 12 (100 o30O) 135 AQREC OR-EC(a) 16 x 16 (4,9 x 4,9) 26 (98) 10.3 (0,71) 4 to 12 (100 to 300) 155,175 AQR-ECIEC 3 mm 0 A 1 4,x5,5) 16 x 18 (4,9 x 5,5) 29 (110) 29(110) 12. 0, 66 6) 12.8 (0,88) 4 i 1o300) 4 to 12 (100 to 300) - 135 AQR-EC AQR-EC/EC 155,175 16 x 20 (4,9 x 6,1) 32(121) 15.6 (1,08) 4 to 10 (100 to 250) . 135 AQR-EC 16 x 20 (4.9 x 6.1) 33(125) 16.6 (1.14) 4 to 12 (100 to 300) 16 x 22(4,9 x 6,7) 35(133) 18.7 (1,29) 4 to 8(100 t0200) 16 x 22 (4,9 x 6,7) 36(136) 19.8(1,37) 4t012(100t0300) 16 x 24(4,9 x 7,3) 39(148) 23.2 (1,60) 4 to 8 (100 to 200) 16 x 24(4,9 x 7,3) 40(151) 24.4 (1,68) 4 to 12 (100 to 300) 16 x 16(4,9 x 4,9) 26(98) 10.3 (0,71) 4 to 12 (100 to 300) 135,155 AEC 5 m 16 X 18(4,9 X 5,5) 29(110) 12.8 (0,88) 4 to 12 (100 to 300) 16 x 20(4,9 x 6,1) 32(121) 15.6 (1,08) 4 to 10 (100 to 250) 135 16x20(4,9x6,1) 33(125) 16.6(1,14) 4 to 12 (100 to 300) 16 x 20(4,9 x 6,1) 32(121) 15.6 (1,08) 4 to 10 (100 to 250) 155 A QR-EC/EC 3 mm 16 x 20(4,9 x 61) 33(125) 16.6 (1,14) 4 to 12 (1 00 to 300) EC(b)16 x 22(4,9 x 6,7) 35(133) 18.7 (1,29) 4 to 8 (100 to 200) 135 AEC 5 m 16 x 22(4,9 x 6,7) 36(136) 19.8 (1,37) 4 to 12 (100 to 300) 16 x 22(4,9 x 6,7) 35(133) 18.7 (1,29) 4 to 8(100 to 200) 155,175 AQR-ECIEC 3 m 16 x 22(4,9 x 6,7) 36(136) 19.8 (1,37) 4 to 12 (100 to 300) 16 x 24(4,9 x 7,3) 39(148) 23.2 (1,60) 4 to 8 (100 to 200) 135 AEC 5 m 16 x 24(4,9 x 7,3) 40(151) 24.4 (1,68) 4 to 12 (100 to 300) 16 x 24(4,9 x 7,3) 39(148) 23.2 (1,60) 4 to 8 (100 to 200) 155,175 AQR-EC/EC 3mm 16 x 24(4,9 x 7,3) 40(151) 24.4 (1,68) 4 to 12 (100 to 300) CENTERLINE OF ( SPRINKLER WATERWAY NO 0-17 FEET I C- 10 FEET LIMIT I MINIMUM I LMINIMUM B 8 FEET MAXIMUM LIMITS OF SINGLE I -- * DEFLECTOR-TO- SPRINKLER COVERAGE CEILING DISTANCE AREA -- -. LI-4- -4-1 1-1/2 to 6" (40 to 150 mm) EXCEPT WHEN USING THE MODEL F700 or F705 RECESSED ESCUTCHEON NOTES: For use in OR-EC and EC Light Hazard Occupancy automatic sprinkler system applications per NFPA 13. For use in EC Light Hazard Occupancy automatic sprinkler system applications per NFPA 13. Requirement is based on minimum flow in GPM from each sprinkler. The indicated residual pressures are based on the nominal K-factor. The centerline of the sprinkler waterway is located 7/16 inch (11,1 mm) below the deflector (Ref. Figure A). For use under smooth level ceilings per NFPA 13. TABLE A-i UL AND ULC LISTING CRITERIA FOR INSTALLATION OF 17/32 INCH ORIFICE MODEL A EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS : ....... 0 ,0 I APPLICATION - - w[ FT. x FT. (m: m) I ...[.0w °pc) GPM (1PM) I PSI (BAR) DEFLECTOR-To- P'tI I%i" - -: INCHES (mm) f TEMP. RATING F SIZE (Ref.) 16 x 16(4,9 x 4,9) 32(121) 16 (1,10) 4 to 12 (100 to 300) 135 AQR-EC 16 x 16(4,9 x 4,9) 32(121) 16(1,10) 4 to 12 (100 to 300) 155 AQR-EC/EC ::I C (4,0 5,5) 36 (136) 20 (1,38) 4 to 12 (100 to 300) 135 AQR-EC 16x 18(4,9x5,5) 36(136) 20(138) 4t0 12 (100to300) 155 AQR-EC/EC QR.EC(aI 16 x 20 (4,9 XCI) _______________ 40 (151) 25 (1,72) ________ 4 to 12 (100 to 300) 125 AQR-EC 3mm 16 x 20(4,9 x 6,1) 40(151) 25 (1,72) 4 to 12 (100 to 300) 155 AQR-EC/EC 16 x 22(4,9 x 6,7) 44(167) 30 (2,06) 4 to 12 (100 to 300) 135 AQR-EC 16 x 22(4,9 x 6,7) 44(167) 30(2,06) 4 to 12 (100 to 300) 155 AQR-EC/EC 16 x 24(4,9 x 7,3) 48(182) 36 (2,48) 4 to 12 (100 to 300) 135 AQR-EC 16 x 24(4,9 x 7,3) 48(182) 36 (2,48) 4 to 12 (100 to 300) 155 A QR-EC/EC 16 x 16(4,9 x 4,9) 32 (121) 16(1,10) 4 to 12 (100 to 300) 135 A EC 5 m 16 x 16(4,9 x 4,9) 32 (121) 16(1,10) 4 to 12 (1100 to 300) 175 AQR-EC/EC 3mm 16 x 18(4,9 x 5,5) 36 (136) 20(1,38) 4 to 12 (100 to 300) 135 A EC 5 m 16 x 18(4,9 x 5,5) 36(136) 20(1,38) 4 to 12 (100 to 300) 175 AQR-EC/EC 3mm 16 x 20(4,9 x 6,1) 40(151) 25(1,72) 4 to 12 (100 t0300) 135 AEC 5 m EC(b)16 x 20(4,9 x 6,1) 40(151) 25(1,72) 4 to 12 (100 to 300) 175 AQR-EC/EC 3mm 16 x 22(4,9 x 6,7) 44(167) 30 (2,06) 4 to 12 (100 to 300) 135 A EC 5mm 16 x 22(4,9 x 6,7) 44(167) 30(2,06) 4 to 12 (100 to 300) 175 AQR-ECIEC 3mm 16 x 24(4,9 x 7,3) 48(182) 36 (2,48) 4 to 12 (100 to 300) 135 A EC 5 mm 16 x 24(4,9 x 7,3) 48(182) 36 (2,48) 4 to 12 (100 to 300) 175 A OR-EC/EC 3mm CENTERLINE OF ( SPRINKLER WATERWAY 10 FEET 0-17 FEET 1 "c- 10 FEET MAXIMUM: MINIMUM I MINIMUM B- 8 FEET MAXIMUM LIMITS OF SINGLE -._ I -- *DEFLECTOR_TO_ SPRINKLER COVERAGE CEILING DISTANCE AREA -. 1-1/2 to 2-1/4" (40 to 60 mm) EXCEPT WHEN USING MODEL F700 or F705 RECESSED ESCUTCHEON (0 NOTES: For use in OR-EC and EC Light Hazard Occupancy automatic sprinkler system applications per FM installation standards. (Maximum room size: 1600 ft2 (150 m2) except for corridors protected by one row of sprinklers. Minimum fire-resistance rating of room walls: 30 minutes.) For use in EC Light Hazard Occupancy automatic sprinkler system applications per FM installation standards. (Maximum room size: 1600 ft' (150 m2) except for corridors protected by one row of sprinklers. Minimum fire-resistance rating of room walls: 30 minutes.) FM requirement is based on maintaining both minimum flow and minimum pressure. The centerline of the sprinkler waterway is located 7/16 inch (11,1 mm) below the deflector (Ref. Figure A). For use under smooth level ceilings per FM installation standards. Specific approvals for the Model F700 and F705 Recessed Escutcheons are given in Figure B TABLE A-2 FM APPROVAL CRITERIA FOR INSTALLATION OF 17/32 INCH ORIFICE MODEL A EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS -3- shut down the fire protecton system and remove the sprinklers. The adjustment provided by the Re- cesseu ueul duces the accuracy to which the length of fixed nine ninnies to the sorinklers must be cut. Also, the Closure has a 112 inch (12.7 mm) wide flanae which provides ample clearance for covering the mounting hole. 'Wl.Wu The 17/32 inch (20 mm) orifice Model A Extended Coverage Horizontal Side- wall Sprinklers and Recessed Ex- tended Coverage Horizontal Sidewall Sprinklers are listed by Underwriters Laboratories Inc. and Underwriters' Laboratories of Canada. They are ap- proved by the Factory Mutual Re- search Corporation and the Scientific Services Laboratory (Australia) and accepted by the City of New York under MEA241-94-E. Specific approvals for the Model F700 and F705 Recessed Escutcheons are given in Figure B. The laboratory listings and approvals only apply to the service conditions indicated in the Technical Data and Design Criteria sections. WARNING The 17/32 inch orifice Model A Ex- tended Coverage Horizontal Sidewall Sprinklers and Recessed Extended coverage Horizontal Sidewall Sprink- lers described herein must be in- stalled and maintained in compliance with this document, as well as appli- cable standards of the National Fire Protection Asociation, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integrity of these de- vices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. The installing contractor or manufacturer should be contacted rel- ative to any questions. Installation of Model A Extended Cov- erage Horizontal Sidewall Sprinklers in recessed escutcheons other than the F700 or F705 will void all sprinkler warranties, as well as possibly void the sprinkler's Approvals and/or Listings. The 17/32 inch (20 mm) orifice Model A Extended Coverage Horizontal Side- wall Sprinklers are rated for use at a maximum service pressure of 175 psi (12.1 bar). The available temperature ratings and finishes are given in Tables B and C, respectively. Recessed versions of the Model A Ex- tended Coverane Horizontal Sidewall Sprinkler are obtained by utilizing the Mnriel A Sorinkler in comhintinr with either the Model F700 or F705 Re- cessed Escutcheon as shown in Fig- ure B. Available finishes for the F700 an1 F70 Fr',itrhôr,r riir, in Table D. The nominal discharge curve plotted in Figure C represents the flow "Cl" in GPM (LPM) as determined by the fol- lowing formula: Q= where the nominal discharge coeffi- cient "K" equals 8.1 (116,8); and, 'p' equals the residual flowing pressure in psi (bar). Listing standards permit the actual value of "K' to vary from 7.4 to 8.2 (106,7 to 118,2); however, for hy- draulic calculations, a K-factor of 8.1 (116,8) is to be applied. The Frame of the Model A Sprinkler, (Ref. Figure A), is brass per ASTM 8176 (C87800), or a proprietary alloy designated as OM. The Button (bulb retainer) is phospher bronze perASTM B103 (C51000 or C52100). The Gas- keted Spring Plate consists of a Beryl- urn Nickel (N03360) disc spring that is sealed on both its inside and outside faces with a Teflont gasket. The Com- pression Screw is bronze per ASTM B140 (C31400) and the Deflector is brass per ASTM 836 (C22000). The OR-EC and QR-EC/EC Sprinklers uti- lize a 3 mm diameter frangible bulb, and the EC Sprinklers utilize a 5 mm diameter frangible bulb. Table B indi- cates the bulb liquid color as a function of temperature rating. The Recessed Escutcheons provided for use with the Model A Extended Coverage Horizontal Sidewall Sprink- ler (Ref. Figure B) have a Closure and Mounting Plate fabricated from low carbon steel. The Mounting Plate prongs, which are compressed back into the Mounting Plate as the Closure is pushed over it, maintain a tight fric- tion fit between the two pieces. The Mounting Plate and Closure can also swivel relative to each other and com- pensate for minor non-perpendicular- ity between the Model A Sprinkler and the wall. DESIGN CRI l:l The 17/32 inch orifice Model A Ex- tended Coverage Horizontal Sidewall Sprinklers and Recessed Extended Coverage Horizontal Sidewall Sprink- lers must only be installed and utilized in Light Hazard Occupancies, under smooth and level ceilings as defined in the applicable installation standard e.y. rrrt hi), anu ii i dQuuruanue wue the criteria given in Table A-i or A-2, ac Pinnfir.phIp Tha nnmirl wpttirri patterns are illustrated in Figure D for tha minim ,m fin"m rOrli Iir3rt fnr typical coverage areas. NOTES .........,..:.,,,,. 7..... than or between those indicated in Table A-i or A-2, as applicable, it is necessary to use the minimum re- quired flow for the next highest width (W) and length (L) for which installa- tion criteria are stated. The Model Extended Coverage Hor- izontal Sidewall Sprinklers and Re- cessed Extended Coverage Horizontal Sidewall Sprinklers must NOT be used with obstructions to heat flow such as beams, joists, or ducts located within the sprinkler coverage area. They may be located along the bound- aries separating adjacent sprinkler coverage areas. NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontal, a small air bubble should be present. The diame- ter of the air bubble is approximately 1/16 inch for the 135'F/57'C, 155'F/68'C, and 175'F/79'C temper- ature ratings. (At higher ambient tem- peratures, the bubble may be barely perceptable for the lower tempera 'ure ratings.) Installation of Model A Extended Cov- erage Horizontal Sidewall Sprinklers in recessed escutcheons other than the F700 or F705 will void all sprinkler warranties, as well as possibly void the sprinkler's Approvals and/or Listings. Model A Extended Coverage Horizon- tal Sidewall Sprinklers and Recessed Extended Coverage Horizontal Side- wall Sprinklers must be installed in ac- cordance with the following instruc- tions. 1. Prior to installing the sprinklers and if applicable, verify that the outer face of the sprinkler fitting is within the proper range of distance which can be accommodated by the type of escutcheon being used. When installing a Model A Horizontal Sidewall Sprinkler with either the F700 or F705 Recessed Escutch- -4- I S !7ñr I I I I FULLY RECESSED FULLY RECESSED DIMENSIONSt DIMENSIONSf Up to 1/2 inch adjustment from Up to 1/4 inch adjustment from minimum 1/4 inch to maximum minimum 1/4 inch to maximum 3/4 inch recessed position. 1/2 Inch recessed position. Dim. Inches mm Dim. Inches mm A- 5/8±1l8tt 159±3,2 A- 112ff 12,7 B-Mm. 3/4 19,1 B-Mm. 1 25,4 B-Nom. 1 25,4 B-Nom. 1-1/8 28,6 B-Max. 1-1/4 31,8 B-Max. 1.1/4 31,8 C-Mm. 1/4 6,4 C-Mm. 1/4 6,4 C-Max. 3/4 19,1 C-Max. 1/2 12,7 HIGH ADJUSTMENT HIGH ADJUSTMENT DIMENSIONS DIMENSIONS Up to 3/4 inch adjustment from Up to 1/2 inch adjustment from the flush sidewall position to the flush sidewall position to 3/4 inch recessed position. 1/2 inch recessed position. Dim. Inches mm Dim. Inches mm A- 112±1/4tt 12,7±6,4 A- 3/8±1l8tt 9,5±3,2 B-Mm. 3/4 19,1 B-Mm. 1 25,4 B-Nom. 1-1/8 28,6 B-Nom. 1-1/4 31,8 B-Max. 1-1/2 38,1 B-Max. 1-1/2 38,1 C-Mm. FLUSH - C-Mm. FLUSH - C-Max. 3/4 19,1 C-Max. 1/2 12,7 APPLICATION APPROVALS FOR RECESSED ESCUTCHEON F700 F705 OR-EC 1,2,4,5, 1,2,3,4,5 EC 1,2,3,4,5, 1,2,3,4,5 FIGURE B MODEL F700 AND F705 RECESSED ESCUTCHEONS -5- Bulb Temperature Liquid Ratinq* Color 135F/57C Orange 155'F/68'C Red 175'79C Yellow * Refer to Table E. —TABLE B— TEMPERATURE RATINGS FOR MODEL A EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS Sprinkler Finishes Natural Brass Chrome Plated Polyester, All Colors — TABLE C— AVAILABLE FINISHES FOR THE MODEL A EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS Escutcheon Finishes Chrome Plated Color Coated, All Colors —TABLED— AVAILABLE FINISHES FOR THE MODEL F700 AND F705 RECESSED ESCUTCHEONS 1 DuPont RQqist, rçf Trmrk Model A Extended Coverage Horizontal Sidewall Sprinkler Model F7000r F705 Recessed Escutcheon Mounting Plate Closure t For best overall appearance. tt Remaining 1/4 inch (6,4 mm) of adjustment can be used to compensate for variations in sprinkler make-in and fitting take-out. Listed by Underwriters Laboratories, Inc. Listed by Underwriters' Laboratories of Canada. Approved by Factory Mutual Re- search Corporation. Approved by the Scientific Services Laboratory (Australia) Accepted by the City of New York under MEA 241-94-E. flU•UUUfltU.uuun,....n. sUflmnueuumann...u,,. JUl.1 ._uuutu. LJj 2I*l!F4uI sfl•fla.fltnnann.nn••I n0uu0s,.nan.. ena..snua..... sum uI9ru.u....sIuu..,4UuuI no" UUUUUISUUUI.IUR. 51* - us1an. : annessenad II•uuauSIuUun... i W anon, Me me IMMIM ••.m "MUM: UlU Auuluuuw...0 '- •1. uuu.Iuuuu.umi...uuiur DEFLECTOR - TO- CEILING: 4 INCHES /BACK WALL FAR WALL 0' SIDEWALL - 8' I i I I I I I I W4ft11 I I 4' LI 31 '.11_il ILlS LII L. WI DEFLECTOR-10 CEILING: 4 INCHES 0 , BACK WALL FAR WALL 01 0 8' SIDEWALL IJLLH I Ii W-I-rUI 4' I •I- 6' 6' 3 CENTERLINE OF 16' X 16' COVERAGE AREA' DEFLECTOR- S U BACK WALL FAR WALL.), 8' SIDEWALL~, NEREEMERME SEEM MEMO • IftII.IIIua.uIIhLIivaaIIIIII mIilirnu. IR !RØIlIUERIIIIr • 01 4' 81 12' 161/ 201 CENTERLINE OF 16' X 20' COVERAGE AREA DEFLECTOR-TO- CEILING: 4 INCHES 01, BACK WALL FAR WALL 1II]*?IiU..... II6 UUUUUiII1' liH LTJILIIl'1!!I III EEE 0' 4' 8' 12' 16' "N 20' 24' CENTERLINE OF 16' X 24' COVERAGE AREA NOTES: Pattern shown with no ceiling mounted obstructions. See Design Criteria and Warranty Sections. FIGURED NOMINAL WETTING PATTERNS AT UL AND ULC LISTED MINIMUM FLOW RATE CONDITIONS -6- SELECTION: USE: Select the appropriate wrench When using an 8 or 10 inch adjustable Crescent based on the following re- type wrench, the wrench is to be applied to the r,Irr+c sprinkler wrench flats only (Ref. Figure A). Model A Sprinklers with a To use the F850 Sprinkler Wrench, slip the natural brass or chrome Wrench opening over the Model A Sprinkler De- plated finish and where the flector by passing the Sprinkler Wrench up from Wrench Hats (as shown in beneath the sprinkler as shown in the adjacent Figure A) are accessible, illustration. may be installed with an 8 or 10 inch adjustable Cres- Using a 1/2 inch ratchet drive or by applying an cent type wrench or the 8 or 10 inch adjustable wrench to the hex end of +, , 4;.,,-, Wrench. the fitting. The two lugs located on opposite sides of the Wrench indicate the orientation of Model A Sprinklers with a the sprinkler frame arms. polyester coated finish must only be installed with NOTE the Model F850 Sprinkler Push on the Sprinkler Wrench, while it is being Wrench. turned, to ensure that the Wrench recess stays fully engaged with the sprinkler wrench flats. Model A Recessed Sprink- lers which are to be in- Carefully remove the Sprinkler Wrench by dis- stalled after completion of engaging it from the sprinkler wrench flats, and the wall must be installed then lowering it down over the sprinkler deflec- with the Model F850 tor. Sprinkler Wrench. (D Model F850 Nylon Coated Sprinkler Wrench FIGURE E SPRINKLER WRENCH SELECTION AND USE r SPRINKLER SPIRIT FITTING EVEL UNENTE~R~LINE6'050mm) OR OF WATERWAY LONGER NIPPLE DEFLECTOR SPRINKLER - FIGURE F LEVELING OF - SPRINKLER FITTING AND DEFLECTOR eon, for best overall appearance, use Dimension Aindicated underthe "Fully Recessed Dimensions" head- ing of Figure B. Otherwise, use Di- mension A under the "High Adjust- ment Dimensions" heading. In either case, the remaining escutcheon plate adjustment can then be used to compensate for the possible man- ufacturing variations in the take-out of the fittings, as well as in the make- in of the sprinklers (as permitted by ANSI 131.20.1). 2. The Model A Horizontal Sidewall Sprinklers must be installed with the centerline of the waterway parallel to the ceiling and perpendicular to a backwall surface. It is recommended that a lightweight spirit level (less than 1 pound), be used to level the sprinkler fitting, as shown in Figure F and that a square be used to check perpendicularity of the waterway centerline to the mounting surface. After installing the F700 or F705 Mounting Plate (or other escutch- eon, as applicable escutcheon) over the sprinkler threads, apply pipe thread sealant sparingly to the sprinkler threads only. Use of a Tef- Iont based pipe joint sealant is rec- ommended. Hand tighten the sprinkler into the sprinkler fitting. Refer to Figure E and select the appropriate Sprinkler Wrench to tighten the sprinkler into the fitting. The word "TOP" on the Deflector must face upwards towards the ceil- ing. The F850 Sprinkler Wrench must be used for installing polyester coated sprinklers, in order to prevent dam- age to the sprinkler finish. NOTES A leak tight 3/4 inch NPT sprink- lerjoint should be obtained with a torque of 10 to 20 ft.lbs. (13,6 to 27,1 Nm). A maximum 30 ft. lbs. (40,7 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to make-up for in- sufficient adjustment in the es- cutcheon plate by under- or over- tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. It is recommended that a lightweight spirit level (less than 1 pound), be used to level the sprinkler Deflector, as shown in Figure F. NOTE The Deflector is angled forward; consequently, the spirit level must be carefully positioned left-to- right when using it to level the Deflector. In recessed horizontal sidewall sprinkler installations, after the wall has been installed or the finish coat has been applied, slide on the F700 or F705 Closure over the Model A Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the wall. Automatic sprinklers must never be shipped or stored where their temper- atures will exceed 100'F/38C and they must never be painted, plated, coated or otherwise altered after leav- ing the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- -7- 396 AQR-EC (3mmBulb) 1 4 _____ 9 SPRINKLER FINISH 135 135F/57'C (A OR-EC & AECONLY) 396 - AQR-EC/EC (3 mm Bulb) ____ NATURALBRASS 155 155'F/68'C (A QR-EC/EC & A EC ONLY) WHITE POLYESTER _______________ 596 AEC (5 mm Bulb) 175 175'F179C (QR-EC/EC CHROME PLATED TABLE PRODUCT SYMBOL NUMBER SELECTION FOR 17/32 INCH ORIFICE MODEL A EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS WITH 3/4 INCH NPT CONNECTION PSN 57 - XXX - .X - XXX "Special Order" Sprinkler Assemblies with ISO 7/1 Thread Connections: age to the sprinklers - both before and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (ref. Installation Section Note.) NOTES Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection system control valve for maintenance work on the fire protection system which it con- trols, permission to shut down the af- fected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. It is recommended that automatic sprinkler systems be inspected quar- terly by a qualified Inspection Service. Seller warrants for a period of one year from the date of shipment (warranty period) that the products furnished hereunder will be free from defects in material and workmanship. The data provided in Figure D is not intended for use as a minimum wetting pattern specification. For further details on Warranty, see Price List. TEMPERATURE RATING A Product Symbol Number (PSN) is not specified when ordering polyester coated Model A Sprinklers with other than a white color; when ordering color coated Recessed Escutcheons with other than a white color; or when order- ing sprinklers with thread connections per ISO 7/1. It is suggested that a color chip be provided when ordering spe- cial color finishes. Otherwise, respon- sibility for duplication cannot be ac- cepted. Contact your local distributor for avail- ability. "Standard Order" Sprinkler Assemblies with NPT Thread Connections: Model A OR-EC (3 mm bulb) Sprinklers: Specify: 17/32" orifice, 135'F, Model A OR-EC Horizontal Sidewall Sprinkler with (specify type) finish, PSN (specify from Table E). Model A OR-EC/EC (3 mm bulb) Sprinklers: Specify: 17/32 orifice, (tempera- ture rating: 155F or 175'F), Model A QR-EC/EC Horizontal Sidewall Sprinkler with (specify type) finish, PSN (specify from Table E). Model A EC (5 mm bulb) Sprinklers: Specify: 17/32" orifice, (tempera- ture rating: 135'F or 155F), Model A EC Horizontal Sidewall Sprinkler with (specify type) finish, PSN (specify from Table E). Model A OR-EC (3 mm bulb) Sprinklers Specify: 17/32' orifice, 135'F, Model A OR-EC Horizontal Sidewall Sprinkler with (specify type) finish and with thread connection per ISO 7/1. Model A OR-EC/EC (3 mm bulb) Sprinklers: Specify: 17/32 orifice, (tempera- ture rating: 155'F or 175'F), Model A QR-EC/EC Horizontal Sidewall Sprinkler with (specify type) finish and with thread connection per ISO 7/1. Model A EC (5 mm bulb) Sprinklers: Specify: 17/32" orifice, (tempera- ture rating: 135F or 155'F), Model A EC Horizontal Sidewall Sprinkler with (specify type) finish and with thread connection per ISO 7/1. Recessed Escutcheon: Specify: 3/4 (19 mm) Model (specify) Recessed Escutcheon with (specify finish), PSN (specify). 3/4' F700 Chrome ........PSN 56-700-9-010 3/4' F700 White ...........PSN 56-700-4-010 3/4' F705Chrome ..........PSN 56-705-9-011 3/4' F705 White ...........PSN 56-705-4-011 Sprinkler Wrench: Specify: Model F850 Sprinkler Wrench, PSN 56-850-4-001. The nominal weights are as follo'vs. 17/32' Orifice Model A Extended Coverage Horizontal Sidewall Sprinkler .........3.0 ozs. (86 g) 3/4' Model F700 Recessed Escutcheon 1.3 ozs. (38 g) 3/4' Model F705 Recessed Escutcheon 1.2 ozs. (34 g) Model F850 Sprinkler Wrench .........15.5 ozs. (440 g) MODEL I I MR S 0 Reg. trademark of GRINNELL CORPORATION, 3 TYCO PARK, EXETER, NH 03833 A tqco INTERNATIONAL LTD. COMPANY