Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2481 PALOMAR AIRPORT RD; ; FA040069; Permit
6/2/22, 9:11 AM FA040069 Permit Data City of Carlsbad Fire Alarm Permit 2481 PALOMAR Job Address: AIRPORT RD Permit Type: FALARM Parcel No: Lot #: 0 Permit No: FA040069 Status: ISSUED Applied 9/7/2004 Approved: 9/23/2004 Reference No.: Issued: 9/23/2004 PC #: Inspector: Project Title: NORTH COUNTY ANIMAL SHELTER FIRE ALARM PLAN CHECK/INSPECTIONS Applicant: TRI-SIGNAL INTEGRATION UNIT 8380 VICKERS SAN DIEGO, CA 858-571-1658 Owner: Fees ($) Add'I Fees ($) Total ($) Balance ($) 200 0 200 0 1/1 006 NORTH COUNTY ANIMAL SHELTER 2481 PALOMAR AIRPORT RD. CARLSBAD, CA. 92009 FIRE ALARM SUBMITTAL Submitted By: Till-SIGNAL INTEGRATION, INC. 9682 VIA EXCELENCIA, SUITE 105 San Diego, CA 92126 (858) 537-3444 CA Lic. # 758792 Contact Ken Boney NORTH COUNTY ANIMAL SHELTER FIRE ALARM SUBMITTAL QIX MODEL # MMiF. CSFM# 1 ALARM CONTROL PANEL AFP-200 NOTIFIER 7165-0028:164 1 REMOTE ANNUNCIATOR LCD-SO NOTIFIER 7120-0028:156 1 DIALER UDACT NOTIFIER 7300-0028:174 1 POWER SUPPLY FCPS-24S6 NOTWthR 7315-0028:225 4 SMOKE DETECTORS FSI-751 NOTIFIER 7272-0028:206 5 DUCT DETECTOR FSD-751P NOTIFIER 3240-0028:205 2 INPUT MODULE FDM-1 N(YflFthR 7300-0028:202 18 MANUAL PULL STATION NBG-12LX NOTIFIER 7150-0028:199 35 STROBE 15CD S1224MC SYSTEM SENSOR 7125-1209:222 2 STROBE 75CD S1224MC SYSTEM SENSOR 7125-1209:222 12 HORN/STROBE 15CD P1224MC SYSTEM SENSOR 7135-1209:223 3 HORN/STROBE 75CD P1224MC SYSTEM SENSOR 7135-1209:223 3 HORN WEATHER PROOF H12/24K SYSTEM SENSOR 7135-1209:143 1 FIRE ALARM BELL KMS-10 NOTIFIER 7135-0028:117 February 19, 2004 DN-3783 A-105 () NOTI Fl ER® Analog Fire Panel Section: Intelligent Fire Alarm Control Panels GENERAL. The AFP-200 Is a compact, cost-effective, Intelligent fire alarm control with a capacity of 198 Individually Identified and con- trolled points and an extensive list of powerful features. The AFP-200 provides capabilities that exceed most large intelli- gent systems, at a cost comparable to conventional control panels. FEATURES 198 intelligent device capacity (99 analog detectors and 99 monitor/control modules). Style 4, 6, or 7. . Overall 301 point capability (198 intelligent points, 4 pro- grammable NAC circuits, 99 programmable relays). Network ready (reference NOTI. FIRE .NETTh and NAM- 232 data sheets for more information). Intelligent features: V Manual sensitivity adjustment. 4/ Day/Night automatic sensitivity adjustment. a-' Drift compensation (U.S. Patent Pending) meets UL requirements as a calibrated test instrument. V Auto detector test (meets NFPA 72). a. Maintenance alert (two separate algorithms). V Pre-alarm (AWACS" U.S. Patent Pending). V Activate local sounder base on pre-alarm. a/ LED blink control for sleeping areas. V Automatic device type check Releasing features: a-' Four independent hazards. A/ Sophisticated cross-zone (three options) a-' Delay timer and Discharge timers (adjustable). V Abort (four options). Optional DACT, with AC fail delay. LCD-80 remote display/control. ACS annunciators (EIA-485), Including LDM custom. Printer interface (80-column and 40-column printers). 5.0 A usable regulated output power, plus 6.0 A expander. (maximum 8.0 A to panel circuits). 80-character LCD display, backlit. Real-time clock, with European format option. History file with 650-event capacity in nonvolatile memory. Includes non-erasable shadow history. Waterfiow or supervisory selection per point. Alarm Verification selection per point, with tally. Walk Test reports two devices set to same address. Positive Alarm Sequence (PAS) Presignal per NFPA 72. Silence inhibit and Auto Silence timer options. March tlme/temporal/Callfomia code for bell circuits. Field-programmable on panel or on PC, with user-defined passwords, plus Autoprogram feature. UL-Listed modem interface allows remote/off-site system Integration. FZM-1 two-wire detector interface provides compatibility with many non-NOTIFIER detectors for retrofit applications (con- suit factory for latest compatibility listings). Dual-rate charger for up to 90 hours of standby power. NOTI.FJRE.NETTh is a trademark of NOTIFIER, 1994. 379311p2.wml Two-Stage option for notification circuits (Canada). Tornado Warning activates different notification circuit code. Non-alarm points for lower priority functions. Remote Silence/Reset/Evacuate via monitor modules. Automatic time control functions, with holiday exceptions. Rapid poll algorithm for manual stations. Responds in < 2 seconds. Operates with untwisted, unshielded wire (up to 1,000 ft.! 304.8 m) for retrofit applications (U.S. Patent 5, 210, 523). UL Listed for Fire Signaling per Standard 864 & NFPA 72. UL Listed for Burglary applications per Standard 1076. UL Listed for Releasing Service. Compiles with NFPA 12, 12A, 12B,13,15,16,17,17A,2001 Standards when Installed In accordance with appropriate NFPA standard. Approved forAgent Release and Preaction/Deluge by CSFM, City and County of Denver, FM, MEA, and ULC. Approved for marine applications by U.S. Coast Guard and Lloyd's Register of shipping. AGENCY LISTINGS AND APPROVALS Listing agencies and file numbers displayed above. These list- ings and approvals apply to the basic AFP-200 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. State Fire ' Marshal California 7165-0028:164 LISTED CS118 S635 (AFP-200C, <*> A FP -20080) IVIE4A. U.S. Coast Guard APPROVED 104-93-E Vol. XI 161.002/23/3 The AFP-200 94/60004 (E2) City of Chicago CLASS 1: 1928E City and County of DENVER NOTIFIERS is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our IS0900 1 product Information up-to-date and accurate. We cannot cover all specific applications I or antielpete all requirements. AS specifications are subject to change without notice. [ .1 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203)484-7118 [NilNEalrl 8 MAI1N I N OTI FE ER' 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS Made In the USA I DN-3783 • 02/19/04 - Peg. tnt 4 I I , .1 I I 'I I I I I I I I I I I I I SYSTEM BLOCK DIAGRAM SLC Intelligent Loop -------------- FSI-751 FSP-751 DEVICES ILIl . NOTlFIRE•NET' Ion Photo FST45I Optional Network Interface Thermal ------------------ NBG.12LX FMM-1 FCM-1 via the NAM-232 j Axed f IDC IAC _. EIA -485 99 software zones phone LDM-32 lines Custom Graphics PRN Series Printer UDACT 783dg.wmI EIA-232 interface for CRT, EiA-485 loop for printer, or PC computer. LCD or LED Four standard annunciators. NotIfication or Releasing 12 AH batteries; 18 AH with 1313-17. 80-character backlit Up to 90 hours standby power. LCD display. Full Alpha keyboard for menu-driven programming. 5 ampere regulated power sup C loop. ) to 198 devices i a single pair wires. Slot for optional module. Volt Am Option. Page 2 of 4 - DN-3783 06/26/02 I f I I I I ., I I .. ALERT Warning at panel of possible fire ACTION Shut off power to equipment monitored by this detector' ALARM Evacuate building and call fire department .3% I AWACSTh' Advance Warning Addressable Combustion Sensing (U.S. Patent Pending) SMOKE OBSCURATION % per foot PREALM SMOKE(PHOTO) PREALM SMOKE(PHOTO) ALARM: SMOKE(PHOTO) FLOOR $ EQUIP RACK 5 FLOOR 3 EQUIP RACK 5 FLOOR 3 EQUIP RACK 5 ALERT: 022% 1.40% 2/e ACTION: 0.51% 1.40% FIRE DEPT CALLED 11:25 P 12/25/93 066 11;36 P 12125/93 D66 11:59 P 12/25/93 D66 TIME -1> ALERT and ACTION levels are completely adjustable In the field to suit the cleanliness and stability of the environment. ALARM levels are field adjustable to one of three levels within the UL permitted range. ACTION levels latch and may be used to perform control functions. ALERT levels self-restore and may be used to activate a local sounder base before general ALARM evacuation. AUTOPROGRAM . 1. PLEASE WAIT 0- CLR I - AUTO 2-POINT 2. 3 - PASSWD 4. MESSAGE 5-ZONES 6-SPL ZONES 7-SYS 8-CHECK 3733v200jpg FIELD PROGRAMMING - 3 WAYS AUTO-PROGRAM .The AFP-200 Identifies all devices that are connect- I ad, determines the type of device, and loads default values (general alarm) Into nonvolatile memory. This Is completed in less than 30 seconds. I ON-LINE EDIT While still providing fire protection, the AFP-200 pro- gram may be completely edited from the front key- pad. Menu trees permit easy change of any param- eter without referral to the programming manual. Re- call, increment and edit function speeds entry of al- phanumeric labels. New program check routine catches common errors. OFF-LINE PC: VeriFire-200 I (included with VeriFire-CD) The complete AFP-200 program may be created in an off-line PC-compatible computer with a Win- dows®-based utility, then loaded Into the AFP-200 .I EIA-232 port. The program may also be off-loaded to a PC at any time. High-speed data transfer com- pletes upload or download In less than one minute. The PC program may also be used to access re- I mote AFP-200 systems over dial-up phone lines, providing detail status information and history file search/sort. . 3 1. I 4. ............ .:....... 1 - ...-. t I • I I .(• .1 I . . -. .. ..4... r4- ::;: :L DN-3783 • 06/26/02 - Page 3 of 4 1 6 LED indicators: AC Power; Fire Alarm; Pro-Alarm; Super- visory/Security; Alarm Silenced; System Trouble. 21 Membrane Switch Controls: Acknowledge/Step; Silence; Evacuate; System Reset; 12-key Alpha pad; 4 cursor keys; Enter, LCD Display: 80 characters (4 x 20) with long-life LED back- light. COMPATIBLE INTELLIGENT DEVICES FSI-751 Ion detector. FSP-751 Photo detector. FSP-751T Photo detector with fixed thermal element. FST-751 Thermal detector, fixed. FST-751R Thermal detector, fixed and rate-of-rise. FSH-751 HARSH Tm photo detector (requires special base). LPX-751L VIEWO laser detector, FSD-751P Duct detector, with housing. FSD-751RP Duct detector, with housing and relay. INTELLIGENT DETECTOR BASES B7IOLPBP Standard flanged base, package often. B50IBP Standard flangeless base, package often. NOTE: Remove BP suffix for single-pack bases, B7IOHD Base for FSH-751 (HARSH) only. B224R8 Relay base. 6224B1 isolator base. B50I8H Sounder base. 850IBHT Sounder base with temporal sounder. COMPATIBLE ADDRESSABLE DEVICES NBG-I2LX Addressable pull station, visible LED. FMM-1 Monitor module. FMM-101 Monitor module, miniature. FDM-1 Monitor module, dual, two independent Class B circuits. FZM-1 Monitor module, two-wire smoke detectors. Page 4 of 4 - DN-3783 • 06/26/02 FCM-1 Control module. FRM-1 Relay module. XP5-M Transponder, monitor, five addressable Class B circuIts; XP5-C Transponder, control/relay, five addressable Class B circuits. lSO-X Isolator module. COMPATIBLE DEVICES, EIA-23 Port (see data sheets) PRU Series: 80-column printer. VS4095/S2: Printer, 40 column, 24 volts. Mounted in external backbox (order from Keltron, Inc.). CRT-2: Video display terminal. NAM-232: Network Interface Module to NOTI• FIRE •NET" wire or fiber models. & I COMPATIBLE DEVICES, RS-485 Port (see data sheets) ACS Series: Remote Serial Annunciator/Control systems. LCD-80: Remote LCD display. LDM Series: Remote custom graphic driver modules. 3 ACM-8R: Remote relay module. Eight Form-C relays. NIB-96: Network Interface Board. RPT-485: Series Repeater, Isolator and/or fiber-optic modem. UDACT: Universal Digital Communicator. PRODUCT LINE INFORMATION AFP-200: AFP-200 system. includes main PC board with dis- play and keypad, backbox and door (gray), hardware and in- struction manual. 120 VAC. AFP-200E: Same as AFP-200, but 230 VAC. AFP-200R Same as AFP-200, but with red backbox and door. AFP-200RE: Same as AFP-200R, but 230 VAC. AFP-200C: Same as AFP-200, but ULC-approved version. AFP-200RC: Same as AFP-200R, but ULC-approved version. DRAFP200*: Replacement door, gray. DR-AFP200R: Replacement door, red. 'Add an E to end of part number for 230 VAC labeling. SBB-4X: AFP-200 backbox (no door), gray, for replacement only. SBB4XR: AFP-200 backbox (no door), red, for replacement only. CAB-AM: Heavy-duty outer enclosure. Required for marine agency approved applications. 4XTM: Plug-In Transmitter Module. Provides municipal box and remote station connection. RTM-8: Plug-in Relay Transmitter Module. Provides eight Form- C relays, plus transmitter. 4XMM: AmmeterNoltmeter. TR-4XG: Gray Trim Ring for semi-flush mounting (TR-4XR foi red). DP-AFP200: Full-length dead-front panel (required for Cana- dian applications). PS-1270: Battery, 12 volt, 7.0 AH, (two required). PS-12120: Battery, 12 volt, 12.0 AH, (two required). PS-12180: Battery, 12 volt, 18.0.AH (two required). APS-611: 6.0 A expansion supply (requires BB-17). 13B-17: Battery box, required for PS-12180, or if APS-6R is used. CHG-120: 120 AH battery charger for use with 25 to 120 AH batteries (see separate data sheet). 411 Series: Digital Alarm Communicator/Transmitter. VeriFire-CD: Programming kit for PC. includes a CD with a variety of VerlFlre Tm programs (including VeriFire-200), cable, and instructions. ROM-AFP200SP: Spanish language kit, includes software IC, manual, and labels. ARCHITECTURAL! ENGINEERING SPECIFICATIONS Specifications are available on CD-ROM with NOTIFIERs Specl-FiraTm software. Contact NOTIFIER for details. SPECIFICATIONS Primary input power, 120 VAC, 50/60 Hz, 3.0 Amps. Total Internal 24 VDC Power - 5.0 A (total shared power V High-ripple regulated power: 1.5A (suitable for ElA4 devices, except ACM-813); 1.0 A maximum standby. V Non-resettable power: 500 mA. V Four-wire smoke detector power: 500 mA. V Four built-In notification circuits: NAC Circuit 1: 2.25 A. • NAC Circuits 24: 2.25 A (shared total). NOTE: with optlonalAPS-6R Power Supply NAC circuits 3 4 are expanded to 3.0 A (8.0 A total power). Battery charger range: 7AH-1BAH. Charge high rate: 29.1 V. Float rate: 27.0 V. Relay contact rating: 2.0 A @ 30 VDC. Cabinet dimensions: 16.125" (40.9575 cm) high x 14.5"(36.8 cm) wide x 5.5 (13.97 cm) deep. SYSTEM CAPACITY Total programmable Input/output points: 301 Intelligent detectors: 99 Addressable monitor/control modules: 99 Programmable NAC circuits in panel: 4 Programmable software zones: 99 Programmable remote relay/annunciator points: 99 LCD-80 annunciators per system: 4 ACS annunciators per system: 10 CONTROLS AND INDICATORS AGENCY LISTINGS AND APPROVALS See page 1 for listing agencies and file numbers. These list- ings and approvals apply to the basic AFP-200 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. I I I I I I 1 I I I Ii I I F Ii I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGlNEERING- BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-0028:164 Page 1 of I Control Unit (Non High-Rise) Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 48.4-1200 FAX (203) 484-7309 Model AFP-200 fire alarm control unit. Local, auxiliary, remote sta t i o n ( P P U ) , p r o p r i e t a r y (PPU) and central station (PPU). Refer to listee's data sheet for a d d i t i o n a l d e t a i l e d p r o d u c t description and operational considerations. System components: 4XTM Transmitter Module RTM-8 Relay Module DP-AFP200, ADP-4 Dress Panel TR-4XG Trim Ring MMX-1, -101 Monitor Module ISO-X Loop Isolator Module N-ELR EOL Resistors CRT-2 Terminal with Keyboard VS4095/5 Printer CMX-1 Control Module BB-17 Battery Box AVPS-24, MPS-24A, -24B Power Supply NAM-232 Network Adapter Module 4XMM Meter Module INA Intelligent Network Annunciator CAB Series' Enclosure ABS-413, ABF-4 INA Cabinet PJ(S-1 Annunciator Key Switch MIB-W, -F, -WF Media Interface Board In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. I I LISTING No. I CATEGORY: LISTEE: I DESIGN I I I I I I INSTALLATION: MARKiNG: APPROVAL Listed as fire alarm control unit for use with separately listed compatible initialing and indicating devices. Suitable for central station (PPU) service when used with separately listed compatible DACT. This control unit can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to manufacturer's Installation Manual for details. Also suitable for releasing service. For releasing application, Models NR-45 battery charger and AVPS-24 power supply shall not be used. Please contact the manufacturer for action. Rev. 11-02-2002 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 17, 2004 Usting Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager California State Fire Marshal ®(LC 0 7120-0028:155 LISTED CS100 MEA S635 , 290-91-E (LCD-80) 289-91-E (LCD-80) FM> 104-93-E Vol. lii (LCD-BOTM) Approved 317..01E (NFs-640) (LCD-80, except NFS-640) 31H8ld84pg H F HOLD FOR STAMM ADJUST C°WmA HOLD FOR L4" TM OLOSAL CXHOM.EDOE H2NCaI E1 IREsETl 0 LCD-BOTM LCD-80 with ABF-IB H H 1 j.NOTIFiER® January 18,2002 DN-3198'D-120 LCD-80 and LCD-SOTM Liquid Crystal Displays Section: Annunciator Control Systems GENERAL The LCD-80 is an 80-character, backlit LCD display annunciator for the NOTIFIER AM2020, AFP1 010, NFS-640, AFC-600, APP- 400, APP-SOD, AFP-200, System 5000, and System 500 fire alarm control panels. Up to 32 LCD-80s may be connected onto the two-wire ElA-485 port. The LCD-80 has two basic modes of operation,'Terminal' and ACS mode. The LCD-80TM shares all the features of the LCD-80, but only utilizes*Terminal' mode, where it mimics the panel display. COMMON FEATURES 80-character Liquid Crystal Display (20 characters x 4 lines), backlighted. Control switches for System Acknowledge, Signal Silence and System Reset. Time and date display field. Enable Key switch and phone Jack options. Can be remotely located up to 6,000 ft. (1828.8 m) from the control panel. Local piezo sounder with alarm/trouble resound. Flush/surface/panel mount option. Optional RPT-485 repeater increases the distance and num- ber of LCD-80s in a system (see RPT-485 data sheet). Optional transmission over fiber optics (see RPT-485 data sheet. ACS MODE When operated in "ACS mode, the LCD-80 provides a remote or local digital display and printer interface for the System 5000 and System 500. Fpr the AM2020, AFP1010, NFS-640, AFC- 600, AFP-400, AFP-300, and AFP-200, the LCD-80 provides a vectored annunciation capability. Individual devices/zones can be installer-defined to only display and print at specific locations (E"MPLE7 A maintenance office receives only non-alarm point activations. These inputs could be sump pump on, high water, backup AHU on, low temperature in freezer, etc.). Alarm/trouble count. Custom'normal" message. European option: first alarm/last alarm/alarm count. Field-programmable messages from CRT or PC-compatible computer (PK-LCD-80 Programming Kit required). EIA-485 interface: up to 32 per system. Printer output port: RS-232, compatible with PRN Series printers. Field-programmable messages in nonvolatile memory in two options: 128 points, 40 character labels; or 256 points, 20 character labels. Internal nonvolatile clock for time and date in ACS mode. AM2020, AFP1010, NFS-640, AFC-600, AFP-400, andAFP- 300 "vectored printer capability. Can be mounted in a System 5000 cabinet module position. I I I I H I I I In Temrinal' mode, the LCD-BC mimics the AM2020, AFP1010, NFS-640, AFC-600, AFP-400, AFP-300 and AFP-200 displays. Up to 32 LCD-80s can annunciate and provide remote reset, acknowledge, and silence of the control panel from remote loca- tions. The DIA-11 and DlA-2020 (Display Interface) include a Terminal mode driver port for LCD-80s in Terminal mode. The Terminal mode port is standard on the NFS-640, AFC-600, AFP- 400, AFP-300, and AFP-200 main PC/CPU boards. Displays device type identifiers. Device and zone custom alpha labels. Time/date and Device address. May operate in addition to CRT. No programming necessary. LCD-80 displays time, date, and custom messages received from AM2020, AFP1010, NFS-640, AFC-600, AFP-400, AFP-300, orAFP-200. This document is not intended to be used for installation purposes. We try to keep our prod- uct information up-to-date and accurate. We cannot cover all specific applications or antici- IS09OO 1 pate all requirements. All specifications are subject to change without notice. For more information, contact NOTIEIR. Phone: (203) 484-7161 FAX: (203) 484-7118 I !_] ()NOTI Fl ER' 12 Clintonville Road, Northford, Connecticut 08472 ffINtERlN& MANliFfliRlN - Made In the U.S-A- Dt4-3198-01118/02 - Page lot 2 System 5000 with panel-mounted LDC-80 398dIaI.wmI System 5000, System 500, AM2020, AFP1010, NFS-640, AFC-600, AFP-300/400, AFP-200, or NCA I The LCD-SO in ACS Mode EIA-232, 4 wires 50 ft. (15.24 rn) max. PRN Printer Il LCD-80 Is 8.25"(20.96 cm) high, 4.375"(11.11 cm) wide, and 1.75" (4.45 cm) deep. Up to 32 LCD-80s may be used on one EIA- 485 circuit. NOTE: Must have sufficient regulated 24 volt power. Certain NOTIFIER systems may have lim- its to the amount of LCD-80s withACK/STER Sig- nal Silence, and Reset switches. LCD-80 mounts with any CHS-4 chassis slot. The LCD-80 may display all System 5000 cir- cuits. Alternately, It may display up to 192AlM- 200 points and two rows of modules. I I 6,000 ft. (1828.8 m) maximum total wire length EIA485 EIA485 EIA485 (2 wires) (2 wires) (2 wires) PRN LCD-80 F121 PRINTER I I' The LCD-CO or LCD -SOTM in Terminal Mode A8F-IDB—TheABF-1DB is 6.000 ft. (1828.8 m) maximum wire length 11 Terminal Mode between each LCD-80 a semi-flush-mount bacithox for Fl— EIA-485 . the NOTIFIER LCD-80 Series (2 wires) Annunciator. The ABF-10B mounts one LCD-80(TM). It in- 24 VDC I I I I D cludes an attractive smoked- (2 wires). ED =1 I glass door with NOTIFIER cjc c:JiJ I II keylock. LCD-80(TM) . LCD-80(TM) LCD-80(TM) J Dimensions, BOX only: high, 9.938"(25.24 cm) _________________ ELA-232 t AM2020, Terminal Mode ElA485 return (2 wires) 4.625"(11.75 cm) wide, Printer Port AFP1010, . 2.5" (6.35 cm) deep. NFS-640. Up to 32 LCD-80(TM)s maybe used in a continuous Dimensions, DOOR only: AFC-600, _ AFP300/400. 4-wire loop (verify sufficient 24 VDC available). 10.713"(27.21 cm) high, ) orAFP-200 Each may have ACK/STEP, SIGNAL SILENCE, and 6" (15.24 cm) wide, SYSTEM RESET switches. 0.75" (1.9 cm) deep. PRN Printer Displays all analog, addressable points. No programming required for LCD-80(TM)s. 24 VDC V 24 VDC (2 wires) (2 wires) rn TO TO cj= PRN LCD-80 PRN LCD-80 PRINTER PRINTER 24 VDC (2 wires) F== RELATED OPTIONS PK-LCD-80 (order VEPJFIRE-CD): Off-Line Programming Kit for LCD-80. Allows PC programming messages when LCD-80 is used In the ACS mode. CCM-1: Converter Module. Required for terminal mode opera- tion on oIderAM2020s orAF01010s that do not Include the DlA- 2020 or DIA-1 010 Display Interfaces. Also required forAM2020 and AFP1 010 systems which'requlre a CRlwfth keyboard. Uses one lCA-4L chassis slot or two CHS-4 chassis slots. See ACS Series (DN-524) or ONXTh ACS Series (DN-6862) data sheets for additional information on items below. ABF-1 DB: Semi-flush box with alternative smoked-glass door, any keylock. ADP-4: Annunciator Dress Plate, gray. Allows panel mounting of up to four LCD-80(TM) modules in a CAB-3 Series cabinet ADP-4B: Annunciator Dress Plate, black. Allows panel mounting of up to four LCD-BO(TM) modules in a CAB-4 Series cabinet. Page 2o12-.- DN-319801118102 ABF-1B: Annunciator Flush Box, 9.938"(25.24 cm) high, 4.625 (11.75 cm) wide, and 2.5'(6.35 cm) deep. Order AKS-1 B key switch and APJ-1B phone jack if desired. Can also be mounted In ABF-2B orABF-4B annunciator backboxes. ABS-ITB: Deep Surface Backbox (mounts one LCD-80/-80TM). AKS-11B: Key Switch (black) to enable/disable controls when mounted InABF orABS-1TS. APJ-IB: Annunciator Phone Jack, black. Mounts toABF flush box orABS-ITS. PRN Series: 80-Column Serial Printer (see PRN data sheet). RPT-485W: ElA-485 Wire Repeater. Increases wire distance between LCD-80s in ACS mode (see RPT-485 data sheet). RPT485F: EIA-485 FIber-Optics Repeater. Increases distance and converts EIA485 wire to fiber-optics in ACS mode (see RPT- 485 data sheet). I I II II CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROACTOYSI OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:156 Page .1 of I CATEGORY: Annunciators LISTEE: Notifier, A Pittway Company, One Fire-Lite Place, Norfhford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Model ACS annunciator control system. Refer to listee's data sheet for additional detailed product description and operational considerations. Unit c o n s i s t s of the following modules: ACM-I6AT, 16ATY*, 16ATG* Control Module ACM32A*, ..3y* -32 AG* Control Module ACM24AT*, ACM-48A' Control Module AEM-24Ar ,AEM48A* Control Module AEM-I6AT Expander Module AEM-32A, ACM-32A Control Module AFM-I6AT, AFM-32A, AFM-16A Fixed Module ABM-I6AT, ABM-32A Blank Module ABS-1, -2, ..113* -213 , -IT-, -1TB- Enclosures (Surface) ABF-1, -ID, -z -21), -4, -1B, 2B*, 413* Enclosures (Flush) ABF-1 DB, 2DB* Enclosures (Flush) ADP-4 Dress Panel AKS-I, .1 B Key Switch LCD-80, -BOTM Control Panel LDM-32 Lamp Driver Module LDM-E32 Lamp Driver Expander LDM-R32 . Lamp Driver Expander (Relay) ACM-BR Mappable Relay Control Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listea's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciator system when used in conjunction w i t h s e p a r a t e l y listed compatible fire alarm control units. *Rev. This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or- recommendation of the item listed. This listing should not be used to verify correct o p e r a t i o n a l r e q u i r e m e n t s o r i n s t a l l a t i o n criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Autho,ized By: DIANE K. AREND, Senior Deputy Program Manager. , I I I I October 24, 1997 D-160 I IióTiFIER® . UDACT ...............L Universal Digital Alarm A Pittway Company Communicator Transmitter Section: Annunciator Control Systems I GENERAL California INDUSTRY (9T The Universal Digital Alarm Communicator Transmitter State Fire CANADA Marshal 2132 6030 A (UDACT) is designed for use on the NOTIFIER AM2020, AFP1010, AFP-400, AFP-300, AFP-200, System 5000 and '\__ 7300-0028:174 System 500 Fire Alarm control panels. In addition, it is S635 CSIOO also designed for use on the Intelligent Network Annuncla- FCC Vol. VII tot (lNA), software release 2.8 or higher. When used in IWGUSA- conjunction with the INA, the UDACT can report the status 20723-AL-E H of all control panels on NOTI • FIRE • NET". The UDACT T" P Fft PM transmits system status to UL listed Central Station Re- fJlEA Ouaoe celvers via the public switched telephone network. 328-94-E E 0 ULJO [J 0 The UDACT Is compact in size and may be mounted exter- nally in a separate cabinet. EIA-485 annunciator commu- nications bus and regulated 24 volt connections are to- ,, quired. IZOA4.AY The UDACT is capable of transmitting the status of soft- (with Ademco 685 only) .. ware zones (Alarm and Trouble), System Trouble, Panel "N ______ Off-Normal, Supervisory, Bell Trouble, Low Battery, and I rs I I AC Fall. When used with the AFP-200, the UDACT trans- C> ABS-BR I I mits up to 89 zones; with the System 500, all 16 zones; for and with the System 5000, all 120 zones. When used with . " " remote the AFP-406, the UDACT Is capable of reporting up to 567 I 10 I mounting *[C~DD! points; with the AFP-300, up to 375 points. Reporting may be in the form of software zones (99 plus 16 special), panel ' (9.94" H x EJ I 4.63'Wx ° 11 1JII1Iff ° U 11111W circuits 1-4, panel output modules 1-64, and 192 points -E 2.5' 0) ______ ... per SLC loop (the first 96 detector and 96 module ad- __ dresses). IIfl/trT When the UDACT is used with the AM2020 orAFP1010, it - L.U4 LIUUUIQ. - Independent zone supervisory. is capable of reporting up to 2,040 points. Reporting may be in the form of software zones (up to 240) or 60 zones - AC (mains) Power Loss (programmable). plus up to 1980 Intelligent points. The first 568 points trans- - Low Battery and Earth Fault. mitted may be programmed for a variety of types, including - System Off-Normal. fire, waterf1ow, supervisory, etc. Remaining points trans- - 12 or 24 hour test signal. mitted are for fire alarm only. - Abnormal Test Signal per new UL requirements. NOTE: Descriptions regarding point capacity, llstedabove - ElA-485 Communication Bus Failure. Annunciation of UDACT Troubles including: loss of phone a re forreceivers which receive in Ademco Contact ID for- J lines, communication failure with either Central Station, mat. See chart on page 2 for compatible receivers, tnfI communications failure. FEATURES Troubleshoot Mode converts keypad to DTMF touchpad. Dual phone lines. individual LEDs for: Power, EIA-485 Loss, Manual Test, Dual telephone line voltage detect. . Kissoff, Comm Fall, Primary Line Seize, Secondary Line Surface Mount Technology. Seize and Modem Communications. Compact in size: 6.75' x 4.25". Open Collectorrelay driverfor Total Communications Fail- Built-in programmer. ure or UDACT trouble. Built-in 4-character red 7-segment LED display. Real-time clock. transient protection. Extensive Manual Test Report function. Simple EIA-485 interface to host panel. Manual Transmission Clear function. Mounts In a separate enclosure (ABS-BR or UBS-1). AGENCY LISTINGS AND APPROVALS Communicates vital system status Including: See above for listing agencies and file numbéls. In some cases, certain - Independent zone fire alarm. modules maynot be listed by certain appro va/agencies, or listing may - independent zone non-fire alarm. be in process. Consult factory for latest listing status. I This document Is not Intended to be used for Installation purposes. We try to keep our ISO-001 Information up-to-date and accurate. We cannot cover all specific applications or I ---------- anticipate all requirements. All specifications are subject to change without notice, For Engineering and Manufacturing more Information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 Quality System Certified to N OTt Ft E 12 Clintonville Road, Northiord, Connecticut 06472 International Standard ISO-9001 Made In The U.S.A. DN4867 - Page 1 of 6 II I I I I .1 INSTALLATION . ORDERING INFORMATION When used with the AFP-200, the UDACT mounts in the UDACT Universal Digital Alarm Communicator Trans- ABS-8R or UBS-1 backbox. When used with the System mitter. Includes operating instructions, pro- 500, the UDACT can mount In the CAB-500 far back (nor- gramming Instructions and mounting hard- mally NIB-96) position. ware. When used with the System 5000, the UDACT can mount MCBL-7 DACT phone cord, seven feet long (two re- in any far back (front module with expander allowed) posi- quired). tion of the CHS-4 chassis. ABS-BR Metal enclosure for externally mounting When used with the AM2020, AFP1010, AFP400, orAFP- UDACT up to 6,000 ft. from host FACP. 300, the UDACT mounts In a CHS4 or CHS4L module UBS-I Metal enclosure. Includes viewing window position, and optional relay mounting capability. In all cases, the UDACT can mount remotely (up to 6,000 MR-1 01/C SPDT Form-C relay. Contacts rated for 10A ft.) in an ABS-8R or UBS-1 backbox. @ 115 VAC. Connects to open collector re- NOTE: Due to space considerations, the far back of the CAB- lay driver. 500 position Is NOT recommended. MR-2011C DPDT Two Form-C relays. Contacts rated COMMUNICATION FORMATS for IOA @ 115 VAC. Connects to open col- lector relay driver. 3+1 Standard • 4+1, Standard • 4+2 Standard FBD-1 Ferrite bead kit. Use for remote mounting 4+1 and 4+2 Ademco Express • Ademco Contact ID only. NOTE: Ademco Contact ID must be used for Independent zone ELECTRICAL SPECIFICATIONS reporting. REQUIRED SOFTWARE Standby current: 40 mA. AFP-200 English EPROM* = 73609 (or higher) Current while communicating: 75 mA. AFP-200 Spanish EPROM* 73618 (or higher) Maximum current while communicating and with open AFP-200 French EPROM* = 73617 (or higher) collector output activated: 100 mA. AFP-400 EPROM* = #AFP4R20 (or higher) Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. System 500 EPROM = 73611 (or higher) System 5000 EPROM* = 73610 (or higher) Format Al S0ent rn Hoffman 8008' Sescoa Sur-Gard = Release 6.6 (or higher) (Addresses 16 Kid hl FBI Models 9500 000R W-2AM2020/AFP1010* 3 & 42) 685(1) 9000 (3) CP23FB 1&2 151 (7) ) AYflflMAflfl = M I 1 4+1 Ademco Epress V J V ( V I Prasentiy, the UDACT Is not capable of A.C. Fail delay (per 1993 NFPA standards) when 1 1 4+2 Ada MOD Bpress V V V (8) V used with the AA SedesAmplifier, AVPS Power Supply, or the XP Transponder. 13+ I/Standard/1 8M2300 I V V (2) V V V V(5,6) V I I TYPE MODE FEATURE 1 3 1 (NOT USED) (Ademco Contact ID format only) Use Type J 4+ 1ISiardi190W14OO I V I V (2)1 1 V (4)1 ' I I V I ' Mode to Identify reports to Central Station I I as: I 5j(NOT USED) I ______ Fire Alarm • Burglary 6 I4+1'S1df180a'2300 V V (2)1 V V V Supervisory • 24 hour Non-Burglary 7 l(woT USED) V (4) I I Pull Station • High Temperature Heat Detector • Low Temperature I 8l4+1/Star1a,d/19O0/1400 V - V(2)j IV(4)I I V V V I _._...... Waterfiow • Low Water Pressure I I(° USED) Duct Detector • Low Water Level I A14+ r1ardf1B3i23O0 I V I V )l s/ V (4)j V V 71 Flame Sensor • Pump Failure Smoke Zone UDACT IBI (NOT USED) IVIVJ Lc4j shown inUBS-1 ICi4+Stha1914OO V ------- ______ one, With 685-8 Line Card with Rev 4.4d software. With 9002 Line Card Rev 9035 software or 9032 Line Card with 9326A software. Rev. 4.0 software. FBI CP220FB Rec-1 1 Line Card with Rev 2.6 software and a memory card with Rev 3.8 software. Model 6500 with Rev 600 software. Model 6000 with Rev 204 software. With Rev B control card at Rev 1.4 software and Rev C line card at Rev 1.5 software. (B) Model 2 only. (9) Version 1.62 software. Page 2 of 6 - DN4867 What is "Contact I.D.' - Most digital receMng forrnatstransmltsimple information about theF status of the site, I.e.; alarm, trouble, supervisory, battery fall, etc. Contact I.D. Is a transmission format enabling transmission of alarm and trouble conditions on a bi-point I basis. Three groups of Information are transmitted to the central station: a four-digit account code, a group number (00 to 9.9), and the device or zone number (000-999). Each of these three information groups is programmable. Because of the virtually unlimited number of combinations, the number of systems, points and/or zones transmitted is boundless. I LOCAL AREA NETWORK APPLICATION The NOTIFIER UDACT (Universal Digital Alarm Communicator Transmitter) provides the means to create a powerful, low cost, local area network solution for any application involving multiple facilities spread over a small geographic area, I such as a college campus. Compatible NOTIFIER fire control panels (System 500, System 5000, AFP-200, AFP-300, AFP-400, AFP1 010, AM2020), NOTIFIER UDACTs, standard public switched telephone network, and a low-cost digital receiver combine to solve what ' has in the past been Impossible to do without incurring high costs. The UDACT, when used in the contact I.D. format, transmits detailed system status via the standard public switched telephone network to a digital receiver, The telephone network becomes the network gateway" from the FACP to the digital receiver and to an optional UnlNet monitor. I In the example shown on the attached page, separate phone lines within each facility tie independently to the UDACT . and modem. For example: Building No. FACP Type 4-Digit Acct. Code Group No. Device/Zone Range I . A AM2020 0001 00 00 001 to 00 999 0001 01 01000 to 01 999 0001 02 02 000 to 02 040 B AFP1010 0002 1 03 1 03 001 to 03 396 I C AFP-200 0003 04 04001 to 04 089 0 System 5000 0004 05 05001 to 05 120 E System 500 1 0005 1 06 1 06 001 to 06 016 I .In this type of configuration, the maximum number of zones/points to be reported Is 100,000. Applications include: hospitals, college campuses, shopping malls, prisons, airports, grouped government facilities, power plants, large commercial facilities and much more. In addition, the control panels may be networked using NOTJ -FIRE 'NET (see DN-4644). in this configuration, a I single UDACT can be used to report uup to 2040 separate points and panel statuses. WIDE AREA NETWORK APPLICATION Imagine an application which requires the status of a fire system to be clearly visible for appropriate response/action, yet the monitored facility is located thousands of miles away from the monitoring center. These applications have in the past been out of reach using existing technology, but today are possible with the NOTIFIER WAN. The NOTIFIER UDACT provides the means to create a unique, flexible, low cost, wide area network solution for any application involving multiple facilities distance by a large geographic area, such as facilities located in various states spread across the continental United States. NOTIFIER WANs are created by using compatible NOTIFIER fire control panels (System 500, System 5000, AFP-200, AFP-300, AFP-400, AFP1010 and AM2020), a NOTIFIER UDACT, the standard pubiicswitched telephone network and a low-cost digital receiver. Reporting the general system status or the specific status of any monitored point In any facility to one central location Is made simple. Controlling the system in this configuration is also made simple by utilizing the NOTIFIER UnlNet, which is network compatible. In the example shown, separate phone lines within each facility tie independently to the UDACT and modem. For example: In this type of configuration, the maximum number of zones/points to be reported is 100,000 and the number of moni- tored facilities is 99. Both the number of points and the number of facilities to be monitored increase when a four-digit account number is applied (as with conventional Central Station facility assignments) as well to expand the network! Multiple response centers are possible, one may be the local monitoring central station facility required by local codes! ordinances. The other monitoring station, as an option, may be located wherever compatible telephone networks exist. DN-4867 - Page 3 of 6 Building No. FACP Type 4-Digit Acct. Code Group No. Device/Zone Range A AM2020 0001 00 00 001 to 00 999 0001 01 01 000 to 01 999 0001 02 02000to02040 B AFP1010 0002 03 03 001 to 03 396 C AFP-200 0003 04 04 001 to 04 089 0 System 5000 0004 05 05 001 to 05 120 E System 500 0005 06 06 001 to 06 016 -Building A Building C - Building B UL listed AFP1 01 AFP-200 Primary Control Modem ID Modem Station )I AM2020 (if required) Modem .09 Local 0 -Telephone Central ) In Office _________________ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Z Network \I ___________ Building E Building D 010 9 PHONE LINES CA S50 Security Non ago BuHding REIA-232 to co UniNet Building A Building C I AM2020 Building B AFP1O1O UControl L listed Primary Station (if required) Building E Building 0 Local NOTI' FIRE •NETTM Telephone I Communications Line AFP-400 AFP-300 Central Office INA Network La 01 JuDAcT 1E rCentral Station Receiver Security UniNet Building kfT I PHONE LINES Video Printer loll rtiiiul - L--------------- --- - ----- - -- -- MM IM - UI - - - a- - - - - - - - loom - - - 1 WIDE AREA NETWORK z 0 0 U, U- 4tUrUKJ1IM LJtYMK I Mtii 'Jr • . .. I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE I USTING No. 7300-0028:174 Page 1 of 1 CATEGORY: Misc. DeviceslControl Unit Accessories I LJSTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact Lawrence Flood (203) 484-1200 FAX (203) 484-7309 I DESIGN: Model UDACT digital alarm communicator transmitter with Model ABS-8R (optional) enclosure. The unit is used to transmit system status to central station via a standard two wire telephone switching network. Refer to Iistee's data sheet for additio n a l d e t a i l e d p r o d u c t d e s c r i p t i o n a n d operational considerations. I RATING: 21.2-28.2 VDC, 40 mA standby, 75 mA alarm, 100 mA trouble. INSTALLATION: in accordance with listee% printed installation instructions, app l i c a b l e c o d e s a n d o r d i n a n c e s I and in a manner acceptable to the authority having jurisdiction. MARKING: Ustee's name, model number and UL label. APPROVAL: Listed as digital alarm communicator transmitter for use with separately listed compatible control units. O831-94 This listing is based upon technical data submitted by the applica n t . C S F M F i r e E n g i n e e r i n g s t a f f h a s r e v i e w e d t h e t e s t r e s u l t s and/or other data but does not make an Independent verthcation of any dawns. This listing is not an endosament or recommendation of the item listed. This listing should not be u s e d t o v e r y c o n e c t o p e r a t i o n a l r e q u i r e m e n t s o r i n s U l a t i o n criteria. Refer to listee's data sheet, installation instructions andIor o t h e r s u i t a b l e i n f o r m a t i o n s o u rces. Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager I July 31, 2002 DN-6927 . E30 .1 /NOTlFlER® GENERAL The FCPS-24S6 (6-amp) and FCPS-24S8 (8-amp) are com- pact, cost-effective remote power supplies with battery charger. The FCPS-24S6/-24S8 may be connected to any 12- or 24- volt Fire Alarm Control Panel (FACP) or may be used as a stand-alone supply. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA re- quirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notill- cation appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alter- nate', the four outputs may be configured as all non-resettable, all resettable, or two non-resettable and two resettable. The FCPS-24S61-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FEATURES FCPS-2456 and FCPS-2458 6-Amp and 8-Amp 24-Volt Remote Power Supplies Secon: Power Supplies LISTED S635 UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex appliances. Cascadable for up to ten power supplies with strobe timing maintained. Operates as a sync follower' or as a sync generator" (de- fault). See note on page 2. Contains two fully-Isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or Jumpered per- manently 0N" (stand-alone mode). Four Class B (Style Y) or four Class A(Style Z, with ZNAC-4 module) NACs. 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load output, with 3 amps maximum/circuit, In NAC expander mode (UL 864). 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous out- put in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Battery charger may be disabled via DIP switch for applica- Optional power-supervision relay (A77-71 6B). tions requiring larger batteries. In stand-alone mode, output power circuits may be config- Fixed, clamp-type terminal blocks accommodate up to 12 ured as: resettable (reset line from FACP required), non- AWG (3.25 mm') wire. resettable, or a mix of two and two. STANDARDS and CODES Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other The FCPS-24S6/-24S8 complies, with the following standards: system peripherals requiring regulated/filtered power. NFPA 72 National Fire Alarm Code. Power-limiting technology meets UL power-limiting require- UL 664 Standard for Control Units for Fire Alarm Systems ments. (NAC expander mode). Form-C normally-closed trouble relay. , UL 1481 Power Supplies for Fire Alarm Systems (stand- Fully supervised power supply, battery, and NACs.. alone mode). Selectable earth fault detection. SPECIFICATIONS AC trouble report selectable for immediate or 8-hour delay. Primary (AC) power: Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- FCPS-24S6/-24S8: 120 VAC, 60 Hz, 3.2 A maximum. cuit (including unfiltered and unregulated bell power). Wire size: minimum #14 AWG (2.0 mm') with 600 V insulation. Requires input trigger voltage of 9.0 - 32 VDC. Control Input circuit: Self-contained in compact, locking cabinet— 15" (381 mm) Trigger Input voltage: 9 to 32 VDC. high x 14.5" (368.3 mm) wide x 2.75" (69.85 mm) deep. Trigger current: 2.0 mA (16-32 V). Per input: 1.0 mA (9 - Includes integral battery charger capable of charging up to 18 16 V) AH batteries. Cabinet capable of housing 7.0 AH batteries. Trouble contact rating: 5 amps at 24 VDC. NOTIFIERS is an operation of Honeywell. This document is not intended to be used for Installation purposes. We try to keep our product infomiation up-to-date and accurate. We cannot cover all specific applications or IS09001 anticipate all requirements. All specifications are subject to change without notice. For more Information, contact NOTIFIER. Phone: (203)484-7161 FAX: (203)484-7118 =t ; • N OTI Fill ER' 12 Clintonville Road, Northiord, Connecticut 06472 MIMS & MitNlIbWTllRD DN-6927 ' 07/31/02 - Page 1 of 3 Auxiliary power output: specific application power 500 mA maximum. - ' Output circuits: +24 VDC filtered, regulated. 3.0 amps maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): for FCPS-24S6: 4.0 amps maximum; for FCPS-24S8: 6.0 amps maximum. Total short-term current for all outputs (NAC expander mode): for FCPS-24S6: 6.0 amps maximum; for FCPS-24S8: 8.0 amps maximum. Secondary power (battery) charging circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. . Maximum charge current: 1.5 amps Maximum battery capacity: 18 AH. APPLICATIONS In some installations, it Is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FOPS-2456/-24S8 can track (i.e., "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attached to the FOPS. When the FOPS-2456/-2458 is configured (via DIP switch set- tings) as a "syAc follower," the FOPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync in- put terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-2456/-2458 is configured (via DIP switch set- tings) as a "sync generator," the FOPS's sync input terminals are not used. Rather, the FOPS is the originator of the strobe synchronization pulses on the FCPSs NAC outputs. In 'sync generator" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. PRODUCT LINE INFORMATION FCPS-24S 6:6.0 amp, 120 VAC remote charger power sup- ply. Includes main printed circuit board, transformers, enclo- sure (15" [381 mm) high x 14.5"[368.3 mm] wide x 2.75"[69.85 mm] deep), and Installation instructions. FCPS-24S 8: 8.0 amp, 120 VAC remote charger power sup- ply. Includes main printed circuit board, transformers, enclo- sure (15"[381 mm} high x 14.5" [368.3 mm] wide x 2.75"[69.85 mm] deep), and installation instructions. ZNAC-4: Class A (Style Z) NAC option module. A77-71 60: 12/24 VDC end-of-line relay for monitoring four- wire smoke detector power. P5-1270: Battery, 12 volt, 7.0 AH (two required, see PS Series data sheet DN-1109). SYNC FOLLOWER/GENERATOR NOTE Example 1: Expand notification appliance power an addi- tional 6.0 amps (FCPS-24S6) or 8.0 amps (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polar- ity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24-volt system power up to 4.0 amps (FCPS-24S6) or up to 6.0 amps (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by connecting the resottable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FOPS Instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FOPS at greater distances" away, from the FACP while expanding system architecture In various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module Is used to sense FCPS trouble conditions. Local auxiliary power output from the FOPS provides power to the addressable control mod- ule. Addressable PA CPs are capable I of locating control and monitor modules at distances of up to 10,000 feet (3048 meters). AGENCY LISTINGS I AND APPROVALS Style Y NAC or Door Holder Power Output #4 NOTE: All NAC outputs can be converted to Style Z with ZNAC-4 option module. FCPS Trouble Contact Output Style V NAC Style V NAC Style Y NAC Output #3 Output #2 Output #1 See the first page of this data sheet for listing agencies and file. numbers. These listings and ap- provals apply to the FCPS-24S6 and the FCPS-24S8. in some AC 10 cases, certain modules or appll- Power cations may not be listed by cer- tain approval agencies, or listing may be in process. Consult fäc- tory for latest listing status. INPUT/OUTPUT FUNCTIONS are programmable by SW1 DIP switch settings 24 VDC Specific Application Power NAC Control input #2 (from FACP) NAC Control Input #1 (from FACP) FCPS Battery Charger Page 2 of 3 - DN-6927 • 07131/02 Sync Input SIMPLIFIED CLOCK DiAGRAM. BOARD LAYOUT TBI: Supervised Earth AC Neutral F AC Hot i L TB1 [J2 cf ci CI F1J1 O Non-Power-LJmited JZ: To Transformer #2 o J1:ToTransformer#1 0 TB2: Power-Umitad, NAC/Out 1 + Supervised In NAC Mode NAC/Out 1 — with Jumpers J5, JPO, NAC/Out 2 + JP7. & JPB in positions NAC/Out 2— shown below. NAC/0ut3t- I __ NACiOut3 Normally Open NAC/Out4+ Normally Closed NAC1Out 4 Common _I1I TBS: Trouble Relay I0 Form-C Fail-Sale (shown energized) T132 7 6 5 4 3 2 1 CD 32 1T85 1P1 1 Lj Lj Lj U Ground Fault Detection .ipi (cut to disable) J3 J3:ZNAC-4 JP2 Connector I L JP2&JP3: Coded/Non-Coded Input Selection Auxiliary Output: 10 —Aux. Common 500 mA Specific- () Application Power + Aux. 24 8 _________— Control Input 2 0 no T + Control Input 000 Out Common D .__ F1(... . . 5 __ _____ — __________ 6 + Out/Trouble Contact 4 ______________ — Control Input 1 Fl: + Control Input 1 Z . . ! Battery 3 0) Co 15A.30V 2 fffi —Sync Input + Sync Input D C. CII:: • 1 0 NOTE: Auxiliary Power Output is power-limited - Battery LEDs (L to R): swi: but NOT supervised. - AC Power (green) Programming a + Battery - Ground Fault (yellow) DIP Switches Co - .JP4: Supervised. - Battery Trouble (yellow) Non-Power-Ijinitod • NAC Trouble (yellow) 18AH,24 VDC - ChargerTrouble/AC Loss (yellow) I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE P R O T E C T I O N OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE i LISTING No. 7315-0028:225 Page 1 of 1 CATEGORY: Power Units I LJSTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 4 8 4 - 7 3 0 9 DESIGN: Models FCPS-24S6 and FCPS-24S8 are power limi t e d p o w e r s u p p l y f b a t t e r y c h a r g e r s u s e d for supervision and expanded power driving capabil i t y o f u p t o f o u r N o t i f i c a t i o n A p p l i a n c e Circuits (FACP Fire Circuits, Signaling Devices) or r e s e t t a b l e / n o n r e s e t t a b l e o u t p u t s . M o d e l ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC I INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority h a v i n g j u r i s d i c t i o n . I MARKING: Listee's name, model number, electrical rating and U L l a b e l . I APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:206 I 1 This listing is based upon technical data submitted by the appli c a n t . C S F M A r e E n g i n e e r i n g s t a f f h a s r e v i e w e d t h e t e s t r e s u l t s and/or other data but does not make an independent v e r i f i c a t i o n o f any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not b e u s e d t o v e r i f y c o r r e c t o p e r a t i o n a l r e q u i r e m e n t s o r i n s t a l l a t i o n I criteria. Refer to listee's data sheet, installation instructions and/or other suitable inform a t i o n s o u r c e s . Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager I I I I I I II November 13, 2002 DN-6714 H-2 FSI-75I and FSP-75I/7517 Low-Profile intelligent Plug-in Smoke Detectors with FlashSccin® Section: IntellIgent/Addressable Devices California State Fire Marshal LISTED C5308 7271-0028:2 S1115 (FSI-751) MARYLAND < > MD State Fire Marshal 277-99-E 2020 (FS!-751) Approved (FSP-751 2013 (FSP-7511-7517) -751TonI #ITI T 8714pno1.1pç FSP-751T with B7IOLP base nei NOTIFIER® GENERAL The NOTIFIER FSP-751 (photo) and FSI-751 (ion) are ana- log, addressable, low-profile (height measures only 1.66°! 42.164 mm) smoke detectors designed for the entire line of Intelligent systems from NOTIFIER. The FSP-751T photo model Includes a built-in thermal (heat) detection device. if either condition (smoke or heat) is detected, the device will alarm. The addressabilityof the FSP-751 and FSi-751 enables the control panel to provide firefighters with a pinpoint descrip- tion of where the fire Is located. The FSP-751 and FSI-751 are also analog devices. The control panel is capable of not only knowing the detector's location but exactly how much smoke is In the chamber of the detector. The detector may be set for different sensitivity settings appropriate to the en- vironment of Its location. Analog devices continually send obscuration values to the con- trol panel These values may be gathered so as to allow the control panel to determine if a detector has accumulated an excessive amount of dirt or dust. A "maintenance" required Indication allows the Installer to clean the smoke detector be- fore an unwanted false alarm occurs. The FSI-751 Intelligent Ionization Sensor Incorporates a unique single-source chamber design to respond quickly and dependably to a broad range of fires. The FSP-751 Intelligent Photoelectric Sensor's unique opti- cal sensing chamber is designed with superior signal to noise ratio. The optical chamber is engineered to sense the pres- ence of smoke produced by a wide range of combustion sources. FlashScan® (patent pending) Is a new communication pro- tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog Intelli- gent devices and certain NOTIFIER systems. Intelligent de- g vices communicate In a grouped fashion. If one of the de- vices within the rtrniin has new Information the nanel's ri I I stops the poll and concentrates single points. Th• FSP-751 with RMK400 recessed mounting kit net effect Is response speed greater than five times that of • VisIble bicolor LEDs blink green every time the detector i, earlier designs. addressed, and illuminate steady red on alarm. __.JI.....I....!..........JA__.......t4fl4 ..,-.1 I FEATURES Sleek, low-profile design (height only 1.66"/42.164 mm). Common base for both photo and Ion detectors, Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Rotary 01 to 159 address switches (01 to 99 on traditional systems). Optional remote, single-gang LED accessory (RA400Z). Dual LED design provides 360° viewing angle. FiashScan® is a registered trademark of NOTIFIER. test with VVIK t5L With dUUW uiSpidy fII dUUIOS UI I VYIII the detector LED: 12-'pause)-1) (FlashScan(D system: only). Built-In functional test switch activated by external rnag- net. Optional relay, isolator, or sounder bases. Listed to UL 268. SPECIFICATIONS Size: 1.66" (42.16 mm) high x 4.1" (104.14 mm) diam:e. Shipping weight: 3.6 oz. (104 g). Operating temperature: 0°C to 49°C (32°F to 120F). I NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our I product information up-to-data and accurate. We cannot cover all specific applications or I IS09001 anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 454-7161 FAX: (203)484-7118 I V d I () NOTI Fl R" 12 Ciintonvliie Road, Northiord, Connecticut 06472 1 lNEEBIN &?tiUF*IUEifi DN-6714 • 11113/02 - Page 1 of 4 SMOKE GUARD Cover: 16 gauge perforated steel (3/16" [4.7625 mm] dia. perforations on 1/4" [6.35 mm] staggered centers). 51% open. SDG-773 is 3"(76.2 mm) deep by 7" (177.8 mm) wide. Frame: 3/4"x 314" (19.05 x 19.05 mm) angle, 14 gauge solid steel. All guards are supplied with the following: Guards fasten to mounting frame with No. 10/24 x 3/8" (9.525 mm) long Alien-head screws (10124 spanner-head screws and tool option at extra cost). Standard finish: "Cool Tan" baked enamel. MOUNTING DIAGRAM (7.62 Cm),: SDG-773 Smoke Guard "'"' '"' L OPTIONAL SDG-773 Smoke C (1.905 cm) 7" (17.78 cm) r Camr or WaQ MODEL NO. SDG-773 UL-Listed velocity range: ION: 0 - 500 ttJmln, (152.4 I mm.). PHOTO: 0-4,000 ft./mln. (1219.2 rn/mm.). Relative humIdIty: 10% - 93% noncondensing. ELECTRICAL SPECIFICATIONS: Voltage range: 15- 32 volts DC peak. Standby current - ION: 200 pA @ 24 VDC (without corr munlcation); 300 pA © 24 VDC (one communication ever 5 seconds with LED enabled). Standby current - PHOTO: 250 pA © 24 VDC (withou communication); 360 pA © 24 VDC (one comniunicatior every 5 seconds with LED enabled). LED current (max.): 6.5 mA © 24 VDC ("ON"). BASES AVAILABLE: BTIOLP: 6.1" (154.94 mm) diameter. B501: 4.1" (104.14 mm) diameter. 850IBH or B501BH1 Sounder base assembly. includes B501 base. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 mm'). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resis- five; 0.3 A @ 110 VDC Inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2" (157.48 mm) x 1.2" (30.48 mm). B524B1 Isolator Base: Dimensions: 6.2" (157.48 mm) x 1.2" (30.48 mm). Maximum: 25 devices between Isolator bases. Duct applications: FSP-751 and FSP-751T are Listed for use in air ducts. See Duct Application Guide A05-1004 for details on pendant-mount applications. NOTE: These prod- ucts are NOT Listed for use inside a duct smoke detector housing. INSTALLATION The FSP-751 and FSl-751 plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder. Mount base on a box which Is at least 1.5." (38.1 mm) deep. Suitable mounting base boxes Include: 4° (101.6 mm) square box. 3-112" (88.9 mm) or 4" (101.6 mm) octagonal box. Single-gang box (except relay or Isolator base). I4'7th B50IBH base, use a 4" (101.6 mm) square box. With B224RB or 2224B1 base, use a 3-1/2" (88.9 mm) octagonal box, or a 4" (101.6 mm) octagonal or squae box. PRODUCT LINE INFORMATION FSl-751 Low-profile Intelligent ionization sensor. Must be mounted to one of the bases listed below. FSP-751 Low-profile intelligent photoelectronic sensor. Must be mounted to one of the bases listed be- low. FSP-751T Same as FSP-751 but Includes a built-in 135°F (57°C) fixed-temperature thermal device. BASES: B7IOLPBP Standard U.S. low-profile base, pkg. of 10. B50IBP Standard European flangeless base, pkg. of 10. B50IBH Sounder base, includes 6501 base above. B50IBHT Same as B50IBH, but includes temporal sounder. B224RB Intelligent relay base. 6224131 Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: SDG-773 Smoke Detector Guard. This guard Is mechani- cally compatible with both FSi-751 and FSP-75 I detectors. If is UL-compatibility listed with the FSP-751 (file UL S5515). It is NOT UL-compat- Iblilty fisted with the FS/-751. FIIO Retrofit replacement flange for BX-501 base. Converts BX-501 base for use with FiashScan® detectors. RA400Z' Remote LED annunciator. 3-32 VDC, Fits U.S. sIngle-gang electrical box. SMK400 Surface mounting kit provides for entry of sur- face wiring conduit. For use with B501 base only. RMK400 Recessed mounting kit. For use with B501 base only. SMB600 Surface mounting kit for use with B71OLP. M02-04-01 Test magnet. M02-09-00 Test magnet with telescope stick. XR-2 Detector removal tool. Allows installation and/ or removal of FlashScan® Series detector heads from base in high ceiling Installations. Extension pole for XR-2. Comes in three five- foot sections. 'Supported by B71OLP and B501 bases only. I I I ii F I I ii I 'Ii I I 1 Page 2 of 4 - DN-6714 • 11/13/02 I DETECTORS, EXPLODED VIEW I I 1 ii I SENSOR _ COVER COVER .Lg llf REMOVAL TABS SENSOR SCREEN SENSING IULJLJLJLJULJI CHAMBER COVER Illi11ilil111l1111i11EIl1u ------ FSP-751 and FSP-751T Photo .AL FSI-751 Ion TEST MAGNET POSITIONING LED 2 PAINTED SURFACE PAINTED SURFACE MAGNET TEST MARKER LED STATUS INDICATORS LED I MAGNET TEST MARKER Ilk, -II i AL FSP-751 and FSP-751T Photo rt PAINTED 61I4mi3.W SURFACE A F.SI-751 Jon DN-6714 11/13/02 - Page 3 of WIRING DIAGRAMS REMOTE ANNUNCIATOR .1.1 I— REMOTEANNUNCIATOR + DO NOT LOOP wire under terminals I or 2. Break wire run to provide supervision of connections. Panel pTj&LA--- -- - - - -/- - - - - - A FSI-751 Ion Page 4 of 4 - DN-6714 • 11/13/02 Ii I I I I I I I F I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE i LISTING No. 7272-0028:206 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 I Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FSP-751, HPX-751, FSP-751T, *FsH..751*(1)FApT..751 *FIpT..851 *Fsp..851 and *FSP..851T photoelectric type smoke detectors. Models FSP-751T and *FsP..851T employ a 135°F supplement integral heat sensor which only assists in .a fire situation. I This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. I RATING: 24 VDC I INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. *Models FSP-751, FSP-751T, *F6T..751 *FAJT51 *FSP.. 851 and *FsP..8511 Models FSP-751 and FSP-7511 are suitable for open areas and inside I duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. *Model FSH-751 is suitable for open areas with air velocity between 0-400 fpm. I NOTE: 1. (')Combined with 7272-0028:208 2. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 07-24-2002 BH I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results . ME, it and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . . . . . . . 01 recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. I Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy I Program Manager Section: Intelligent Addressable Devices MEA 143-00-E (FSD- 751P) 38900E Approved LISTED CS308 (FSD-751RP) (FSD- 75 IPA, S1115 FSD-75IRPA) MARYLAND California State Fire Marshal State Fire Permit #2036 (FSD-751P) Marshal Permit #2060 (FsD-751R?) 3240-0028:205 June i~D-751 001 DN-6821 H-215 Pand FSD-751RP NOTIFI.ER®/ Intelligent Photoelectric Duct Smoke Detectors with FlashScan® I I I U I I I GENERAL An l-IVAC system supplies conditioned air to virtually every area of a building. Smoke introduced into this air duct system Is thus distributed to the entire building. Smoke detectors for use in air duct systems sense the presence of smoke In the duct. The FSD-751 Pair duct smoke detector is a photoelectric detector, combining this detection technology with an efficient housing design that samples all-passing through the duct, allowing detec- tion of a developing hazardous condition. When sufficient smoke is sensed, an alarm signal is initiated at the fire control panel monitoring the detector, and appropriate action can be taken to shut off fans and blowers and change over air handling sys- tems, etc. This can isolate toxic smoke and fire gases or prevent their distribution throughout the areas served by the duct system. Two LEDs on each detector can be programmed bythe system control panel to provide a local alarm indication. A remote alarm output is provided for use with auxiliary devices. The FSD-751 P has remote test capability with the RTS451/RTS451 KEY Remote Test Station. Traditional panels support addresses of 0-99. The FlashScan® protocol supports addresses of 0— 159. Patented FlashScan® is a new communication protocol developed by NOTIFIER Engi- neering that greatly enhances the speed of communication be- tween analog Intelligent devices. Intelligent devices communi- cate in a grouped fashion. If one of the devices within the group has new information, the panel stops the group poll and concen- trates on single points. The net effect is response speed greater than five times that of earlier designs. APPLICATIONS Duct smoke detectors have specific limitations. Duct smoke detectors are: WOTa substitute for open area smoke detectors. MOT substitute for early warning detection. NOTa replacement for a building's regular fire detection sys- tern. Call NOTIFIER for a copy of System Sensor's application guide, Proper Use of Smoke Detectors in Duct Applications, (A05- 1004-00). INSTALLATION Wiring: For signal wiring (the wiring between detectors or from detectors to auxiliary devices), it is recommended that single conductor wire be no smallerthan 18 AWG (0.75 mm'). The duct smoke detector terminals accommodate wire sizes up to 12 AWG (3.25 mm'). Flexible conduit is recommended for the last foot (30.48 cm) of conduit solid conduit connections may be used if desired. Smoke detectors and alarm system control panels have specifi- cations for Signaling Line Circuit (SLC) wiring. Consult the con- trol panel specifications for wiring requirements before wiring the detector loop. The FSD-751 P/FSD-751 RP detector Is de- signed for ease of wiring; the housing provides a terminal strip with clamping plates. LED Features: If programmed with the system control panel, two LEDs on each duct smoke detector light to provide local visible indication. Remote LED annunciator capability is avail- able as an option. Each duct smoke detector can only be wired to one remote accessory. NOTIFIER panels offer different feature sets across different panel models. As a result, certain features of the FSD-751P1 FSD-751RP may be available on some control panels, but not on others. Possible features, if supported by the control panel are: Panel controls the LED operation on sensor. Operational modes are: RED blink, RED continuous, GREEN blink, GREEN continu- ous, and OFF. SPECIFICATIONS FSD-751 P Operating voltage range: 15 to 32 VDC, Standby current: 300 pA @ 24 VDC (one communication every 5 seconds with LED blink enabled). Operating temperature range: 32° to 131°F (0° to 55°C). HumIdIty range: 10°h to 93% (non-condensing). Duct air velocity: 500 to 4,000 feet/mm. (152.4 to 1219.2 meters/ mm.). Dimensions: 14.375"(365.125 mm) wide x 5.500"(13.970 mm) high x 2.750"(69.850 mm) deep. Options: RTS-451, RTS451KEY, RA400Z. Separate auxiliary power not required. FSD-751RP Operating voltage range: 15 to 32 VDC (Comm. line voltage) and 24 VAC/VDC or 1201240 VAC auxiliary power (separate source). "NOTE: The FSD-75IRP requires a separate auxil- ian,' source. Standby current: 300 pA @24 VDC (one communication every 5 seconds with LED blink enabled). Auxiliary power current draw (@ 24 VDC): 26 mA (standby), 87 mA (alarm). Options: RTS-451, RTS-451KEY, RA400Z,APA451. FlashScan® is a registered trademark of NOTIFIER. I I F I 1 This document Is not Intended to be used for Installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more Information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ;to , () P4 OTI Fl ER' 12 Clintonville Road, Northford, Connecticut 06472 ENSIIEMNG & MANUMCTIIRIN - - DN-6821 ' 06/05/01 - Page 1 of 2 Operating temperature range: 32° to 131°F (0° to 55°C). Humidity range: 10% to 93% (non-condensing). Duct air velocity: 500 to 4000 feet/mm. (152.4 to 1219.2 meters! mm.). Dimensions: 14.375"(365.125 mm) wide x 5.560"(13.970 mm) high x 2.750° (69.850 mm) deep. Relay contact ratings. 2 Form-C, DPDT, 10 A @250 VAC, 10 A @ 30 VDC (resistive), Minimum switching current of 100 mA @ 5VDC. Programming specifications/requirements for intelligent system control panels: The number of devices that can have their LEDs programmed to illuminate is limited by the features of the panel and the individual devices. The actual number of devices is determined by the control panel and its ability to supply LED current. Refer to the control panel installation manual for details. INLET TUBE SELECTION Outside Duct Width Inlet Tubt Up to 2 feet (0.6096 m) I ST-1.4 2 to 4 feet (0.6096 to 1.2192 m) ST 4 to 8 feet (1.2192 to 2.4384 m) ST. 8 to 12 feet (2.4384 to 3.6576 m) ST-1 "NOTE: Inlet tube Is required and must be purchased separately. Order one in/el tube for each duct smoke detector ordered. I FSD-751P Detector Terminals iii 1 6821 WI3.wml COMMON ITEST (1) ® (i) \ield-Installed JUMPER -( (2) () LED T RESET RTS451/RTS451 KEY >- I - UJ Ln _ - ZE w<-0OO The RTS45I The RTS451 KEY I I; .-- — -- Detector — SAMPLE WIRING DIAGRAMS 00 (-'U PRODUCT LINE INFORMATION Model Description FSD-751P Duct detector housing with FlashScan®photoelec- tric smoke detector. FSD-751RP Duct detector housing with FlashScan®photoelec- thc smoke detector, DPDT relay. ST-1.5 Metal sampling tube, duct widths ito 2 (see fable at left for metric lengths). ST-3 Metal sampling tube, duct widths 2' to 4. / ST-5 Metal sampling tube, duct widths 4' to 8. ST-b 0 Metal sampling tube, duct widths 8' to 12'. RA400Z Remote annunciator alarm LED. RTS45I Remote test station. Mounts in single-gang box. Includes red alarm LED and magnet test switch. R IKEY irg, Key-activated remote test station. ~1 4119-00 Replacement filters. 102-04-O0 Replacement test magnet. S08-39-01 Replacement photo insect screen. P48-55-00 Replacement end cap for plastic sampling tube. P48-21-OD Replacement end cap for metal sampling tube. A5053FS Replacement photoelectric sensor board. A5067 Replacement power board (without relay). A5060 Replacement power board (with relay). The R.4400Z 4 FSD-751P Duct Smoke Detector with RTS45II R1S451 KEY NOTE: For RTS45I, Terminal 3 is not used. RTS451 does not have a Terminal 6. For RTS45IKEY, Ter- minals 3 and 6 are not used. I [1 I I Ii I I I I 11111 I I COMMUNICATION LINE UL Listed Control Panel See product Installation Intructians for wiring diagrams for the FSD-75IRP. 2nd Detector in Loop 8821w1r1.wml 4 FSD-751P Duct Smoke Detector using a UL Listed control panel 6821 w1r2.wmf 4 FSD-751PDuct Smoke Detector with optional RA400Z N Page 2 of 2 - DN-6821 - 06/05/01 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM i LISTING SERVICE LISTING No. 3240-0028:205 Page 1 of I CATEGORY: Duct Smoke Detector Housing/Base l LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact Lawrence Flood (203) 484-1200 FAX (203) 282-7309 I DESIGN: Models FSD-751P, -751 PL, -751 RP, and -751 RPL duct smoke detectors. Units consist of an enclosure, electrical components, sampling and exhaust tubes, and listed photoelectric smoke detector sensor. Refer to listee's data sheet for detailed product description and operational I considerations. I RATING: 15to32VDC INSTALLATION: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical and air velocity rating and UL label. I MARKING: APPROVAL: Listed as duct smoke detectors for use with separately listed compatible fire alarm control units. *Models FSD-751PL and -75IRPL are suitable for use in ducts where air velocity vanes I between 100 and 4000 fpm. *Models FSD-751 P and -751 RP are suitable for use in ducts where air velocity varies between 500 and 4000 fpm. Refer to listee's Installation Instruction Manual for details. - I I 12-03-03 I ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation I criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 I Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROT E C T I O N OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE USTING No. 7300-0028:173 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories USTEE: Notifier, One Fro-Lite Place, Northiord CT 06472-1653 Contact Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models BX501, 136101-P, B612LP, B614LP, B6I6LP and B71OLP detector bases. Refer to listee's data sheet for additional detailed product descripti o n a n d o p e r a t i o n a l c o n s i d e r a t i o n s . INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having Jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL- Listed as detector bases for use with separately listed compatible detectors. XLF: 7300-1209:128 07-29-94 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This listing is not an endorsement or recommendation of the item fisted. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suita b l e i n f o r m a t i o n s o u r c e s . Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager I Lii I I 1 I I I I I I I INSTALLATION AND MAINTENANCE INSTRUCTIONS RTS45IKEY(A) Remote Test Station SYS TA i SEN. 5 3825 Ohio Avenue, St. Charles, II 1-800-SENSOR2, FAX: 6 Specifications Dimensions: 4.6" H x 2.75" W 1.8" D Weight: 0.22 Lbs. Power Requirements Power LED (Green): 14 - 35 VDC, 12 mA maximum Alarm LED (Red): 2.8 - 32 VDC, 7.5 mA maximum Total Current: 103 mA maxinum. Alarm Response Time: 40 seconds maximum Temperature: —10°C to 60°C (14°F to 140°F) Humidity: S 95% relative humidity, noncondensing NOTICE: This manual shall be left with the owner/user of Figure 1. RTS45IKEY: this equipment. I NOTE: A test coil is required only for use with DH400/ DHSOO models and requires ordering of part #COIL. () General Information *u I The System Sensor RTS451KEY(A) is an automatic fire detector accessory designed to test remotely located duct and beam detectors. For 4-wire detectors, the RTS451KEY I features a multi-colored LED that alternates between steady green and red. Green indicates power and that the detector board is in place. Red indicates alarm. For 2-wire detectors, I the LED will show red for alarm. Consult the detector in- stallation instructions for additional information. G The National Fire Protection Association has published ' codes, standards, and recommended practices for the in- stallation and use of this product. It is recommended that Operation the installer- familiar with these requirements, with local . I est Function codes,.and any special requirements of the local authority Insert the key and turn clockwise to the 'TEST" posi having jurisdiction. . Alarm Indication I RT5451 Contents 1 With the key in the "TEST" position, some time will RTS451KEY(A) remote test station (40 seconds maximum) depending on the detector 1 #4 screw for mounting bracket before the alarm indicating LED will turn red. I i screw pack (2 mounting screws) 2 Keys Reset Function Thm the key counterclockwise to the "RESET" positio I hold. The LED should turn off. Then, turn the key to the "NORMAL" position and remove. The RTS45 is capable of resetting only certain models of dete I . . Refer to the detector installation instructions for addit information. I D440-03-00 . . I I I I I I Figure 3. Wiring diagram for RTS45IKEY to DH1 duct smoke detector. NOTE: Terminal 6 of the RTS451KEY is not used wired to a 2-wire detector. Figure 2. Wiring diagram for RTS45IKEY to DH100ACDC duct smoke detector. RTS451 KEY (Red LED) Alarm (Green LED) Power Alarm Signal Aux. Power + Sup. N.O. Sup. COM Aux. Power— Reset DHIOO RTS-451 K Test + Test Teal/Reset— (13 Resel+ I13 I F -i RA+® I Alarm Re RA —® 2 VOtjt+ I (ij No Connection 1 I I 1 I I I I I I I I I Wiring Instructions In Canadian applications, the RTS451KEYA is inten Consult the appropriate detector Installation instructions be located in the same room as the smoke detect for the applicable wiring diagram. The RTS451KEY mounts within 60 feet of the unit. to a single gang box (21/2"minimum depth), or directly to the wall or ceiling. Field ./ Installed Jumpers Test 150193.00 `.1 Three-Year lJmlted Warranty System Sensor warrants Its enclosed remote test station to be free from Repair Department, RA # . 3825 Ohio Avenue, St. Charles defects In materials and workmanship under normal use and service for a 60174. Please Include a note describing the malfunction and suspec period of three years from date of manufacture. System Sensor makes no cause of failure. The Company shall not be obligated to repair or repi other express warranty for this remote test station. No agent, represent- units which are found to be defective because of damage, unreasoni alive, dealer, or employee of the Company has the authority to Increase use, modifications, or alterations occurring after the date of mnanufacti or alter the obligations or limitations of this Warranty. The Company's In no case shall the Company be liable for any consequential or incidet obligation of this Warranty shall be limited to the repair or replacement of damages for breach of this or any other Warranty, expressed or imp] any part of the remote test station which Is found to be defective In mate- whatsoever, even If the loss or damage Is caused by the Company's n rials or workmanship under normal use and service during the three year Ilgence or fault. Some states do not allow the exclusion or limitation period commencing with the date of manufacture. After phoning System incidental or consequential damages, so the above limitation orexcius Sensor's toll free number 8OO-SENSOR2 (736-7672) for a Return Autho- may not apply to you. This Warranty gives you specific legal rights, rization number, send defective units postage prepaid to: System Sensor, you may also have other rights which vary from state to state. - D440-03-00 2 - - 156-758 02003 System Sen CALIFORNIADEPARTMENT OF FORESTRY & 1E PROTECTRN ' OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1209:129 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: System Sensor, 3825 Ohio Ave., St. Charles IL 60174 Contact: *Trish Linhart (630) 377-6674 Fax (630) 377-7245 DESIGN: Models RTS45I and RTS45I KEY remote test switches, and Model RTC remote test station Idt. Refer to Iistee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with Iiste&s printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as accessory devices for use with separately listed compatible duct smoke detectocs. NOTE: Formerly 7300-0087:129 Rev. 06-16-2003 TI-is listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to hstse's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 I Authorized By: DIANE K. AREND, Senior Deputy Program Manager LISTED CS669 APPROVED S635 U.S. Coast Guard 0 161.00212313 (AFP-200: FMM-1I-101, FLU-1) 161.002142/I California (NFS-640: FMM-11-101) State Fire Marshal 7300-0028:202 93160141 (E3) (FMM-11-101, FZM-l) 94/60004/E2 (AFP200: except FDM-1) 02/60007 (NFS-640: FDM-1) MEA 143-01-E (FDM-1) 317-01-E (FMM-1I-101) 345-02-E (FMM-1/- 101) 457-99-E (FZM- 1, FMM-1/-101) 447-99-E FMM-1 and FZM4 (O.NOTIFIER August 23, 2004 ON-6720 H-220 FMM-, FMM-01, FZM-, FDM-1 Monitor Modules with Flash$can® Section: lntelilgentlAddressable_Devices GENERAL Four different monitor modules are available for NOTIFIER in- telligent controls to suit a variety of applications. Monitor mod- ules are used to supervise a circuit of dry-contact input de- vices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1). FMM-1 - is a standard-sized module (typically mounts to a 4" [10.16 cm) square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input de- vices. FMM-101 - is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270cm) 0) used to supervise a Class B (Style B) circuit. Its compact design allows the FMM-101 to often be mounted In a single-gang box behind the device Its monitoring. FZM-1 - is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit FDM-1 - is a standard-sized dual monitor module used to monitor and supervise two Independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan@ (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between ana- log Intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FIashScar4l is a registered trademark of NOTIFIER. FMM-1 MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMFJRFI) immunity. SEMS screws with damping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan®sys- tems, 01 —99 on CLIP systems. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1 Monitor Module is intended for use In Intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (lDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 can be used to replace MMX-1 mod- ules in existing systems. 0 1'91H- (8 01,11411 detaofFDM-1 il - note ,es" I ll'1i 2 addresses are O,2,4,6,8only I kOOP ADDRESS FMM-1 Applications - Use to monitor a zone of four- wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally- open supervisory devices with special supervisory Indica- tion at the control panel. Monitored circuit may be wired as an NFPA We B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for su- pervision of the Style D circuit.. Maximum IDC loop length is 2,500 ftJ762 m (20 thins maximum). NOTIFIERS is a Honeywell company. This document Is not intended to be used for Installation purposes. We try to keep our IS09001 product information up-to-date and a= rate. We cannot cover all specific applications ______________ or anticipate all requirements. All specifications are subject to change without notice. r d i i For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 UARM a M1ThJl P4OTIFIER l2 Clintonville Road. Ncwthford. Connecticut D6472 •UALITT SYSTEMS DN-6721} • 08(23(04 - Page 1 of 6 FMM-I Operation - Each FMM-1 uses one of 159 avail able module addresses on an SLC loop. it responds to regii lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC) A flashing LED indicates that the module Is in communica tion with the control panel. The LED latches steady on alarrr (subject to current limitations on the loop). FMM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current 375 hA (LED flashing). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2125" (5.398 cm) deep box. FMM-101 MINI MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the panel. Powered directly by two-wire FACP. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01- 159 on FlashScan®sys- tems, 01 -99 on CLIP systems. 141501 I_ADDRESSI 01 I 12?)2 fI —'2I 111 6 O5 5 I 1 62 _LOOP 7 6 j 987 ))I 9 ( 6 TENS ONES The FMM-101 Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101 is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches, it provides a two-wire Initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101 can be used to replace MMX-101 module in existing systems. F MM-1 01 Applications - Use to monitor a single de- vice or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry- contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device, is wired as an NFPA Style B (Class B) Initiating Device Circuit A 47K ohm End-of- Line Resistor (provided) terminates the circuit. FMM-I01 Operation—Each FMM-101 uses one of 159 available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). FMM-I01 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum operating current 375 hA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity, range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75"(6.985 cm) wide x 0.5" (1.270 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-I INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with damping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan® sys- tems, 01 -99 on CUP systems. LED flashes during normal operation (this is a program- mable option). LED latches steady to indicate alarm on command from control panel. The FZM-1 Interface Module is intended for use in Intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional de- tectors back to the control panel. All two-wire detectors be- ing monitored must be UL compatible with the module. The FZM-1 has a panel-controlled LED indicator and can be used to replace MMX-2 modules In existing systems. FZM-1 Applications - Use the FZM-1 to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Ini- tiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (pro- vided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance 1s25 ohms). Install ELR across terminals 8 and 9 for Style 0 application. FZM-1 Operation - Each FZM-1 uses one of 159 avail- able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (I DC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current imitations on the loop). FZM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current 255 hA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 Vmo maximum. Current. 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4 (10.16 cm) square x 2.125" (5.398 cm) deep box. - t.- 0 O 0 I 0 ILLi co I Page 2 of 6— 0P4-6720 • 0823/04 Lt5?1(ffiöNI Avoid duplicating addresses on the system. CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING Face Plate for FMM-1, FZM-1, and FDM-1 MOUNTING DIAGRAMS For standard-ized modules DN-6720 • 08/23104 - Page 3o16 FDM-1 DUAL MONITOR MODULE The FDM-1 Dual Monitor Module is intended for use in in- telligent, two-wire systems. It provides two independent two- wire Initiating device circuits (IDCs) at two separate, consecu- tive addresses. It Is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or normally dosed security devices. The module has a single panel-controlled LED. NOTE: The FDM-1 provides two Class B (&yle 10 IDC circuits ONLY. Class A (We Z) IDC circuits are NOT supported in any application. FDM-1 Specifications Normal operating voltage range: 15 to 32 VOC. Maximum current draw: 5.7 mA (LED on). Maximum operating current: 750 VA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wiring resistance: 1,500 ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.57 (11.43 cm) high x 4" (10.16 cm) wide x 2.125° (5.398 cm) deep. FDM-1 Automatic Addressing —The FDM-1 auto- matically assigns itself to two addressable points, starting with the original address. For example, If the FDM-1 is set to address "56°, then It will automatically assign Itself to ad- dresses °56 and "5T. NOTE: "ones°addresses on the FDM-1 are 0, 2, 4, 8, or 8 only. Terminals 6 and 7 use the first ad- dress, and terminals 8 and 9 use the second address. INSTALLATION F?IM-1, Foil-I, and FZM-I modules mount cflredJy to a stan- dani 4" (10.16 an) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and Installation instructions are pro- vided with each module. All wmng must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only The FMM-101 module is Intended to be wired and mounted without rigid connections Inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. PRODUCT LINE INFORMATION FMM-1 Monitor module. FMM-101 Monitor module, miniature. FZM-1 Monitor module, two-wire detectors FOM-1 Monitor module, dual, two Independent Class B circuits. SMB500 Optional surface-mount backbox. ARCHITECTS'/ENGINEERS' SPECIFICATIONS Specifications of these and all NOTIFIER products are avail- able from from NOTIFIER. I WIRING DIAGRAMS The following wiiing diagrams are included 1) FDM-1, typical dual two-wire Style B initiating device circuit configuration. I 2) FMM-1 01, typical two-wire Style B Initiating device circuit configuration. FMM-1, typical two-wire initiating circuit configuration, NFPA Style B. FMM-1, typical four-wire fault-tolerant Initiating circuit configuration, NFPA Style D. I 5) FMM-1, typical two-wire initiating circuit configuration for security systems (with alarm versus shaft capability). 6) FZM-1, interface two-wire conventional detectors, NFPA Style B. I 7) FZM-1, Interface two-wire conventional detectors, NFPA Style D. 8) FRM-1, relay control module used to disconnect a power supply. Y1!j I 1l [ci'] c2 1!p'a J I Fig. I FDM4: Typical dual two-wire Style B initiating device circuit configuration. I Two Initiating Device Circuits ' (L&H) TO Next - each power-limited to Device - FROM Pane! or Previous 230 pA max. @ 12 \JDC max. MONITOR Device I 47K EOL H d MODULE Resistor Communication Line ELR-47K 0 32VDC maximum. 0 Twisted-pair is I 8 + recommended. 7 1DS 47K EOL L • All wiring shown is supervised Resistor 4 I and power limited. Connect modules to listed compatible ELR-47K o 2 NOTIFIER control panels only. ANY NUMBER of UL Usted contact closure devices may be used. 62wii.nf I . DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit Install contact closure devices per manufacturer's installation instructions. TO I N H::~ y I DEVICE UL LISTED J BLAClO Compatible H () FMM-101 Control 5 6789 10 5678 9 ' 40'11 4 2 13 2 iT 10 1514 1 an (+) (—) VIO1.EflI 14 YELLOW 47K EOL INCLUDED Fig. 2 FMM-101: Typical two-wire Style B initiating device circuit configuration. Page 4of6— DN-6720•0a'23.104 . Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Install contact closure devices per manufacturers' installation instructions. Any number of UL-listed contact closure devices may be used. DO NOT MIX fire alarm Initiating, supervisory, or security devices on the same circuit. V Fig. 3 FMM-I: Typical two-wire initiating device circuit configuration, NFPA Style B. I 47K EOL Resistor ELR-47}( TO Next Device MONITOR Initialing Device Circuit (IDC) NFPA Style B, power limited: 230 pAmax.©12 VDCmax. 97jTm 2 Communication Loss (optional connection for panels which support this feature) FUTURE FEATURE 6720wi2.wit U -. FROM Panel or Previous Device Communication Line 32 VDC maximum. Twisted-pair is recommended. V Fig. 4 FMM-1: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. EOL Resistor Is Internal at terminals 8 & 9 FROM Panel or Previous ±L41 Device Communication Line 32 VDC mmdmum. Twisted-pair is recommended. 11 ( _J— Communication Loss LOOP ONES ADD1] (optional connection for panels 0 which support this feature) FUTURE FEATURE U TO Next Device -._.•- 011 MIN will 'V Fig. 5 FMM-1: Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). Initiating Device Circuit (IDC) NFPA We B, power limited: 230 pA max. @ 12 VDC max. 14K Series Resistor, 47K EOL Resistor ELR-47K FROM Panel or Previous _L4 Device Ifl.'sl I-i1J MIS Communication Line 32 VDC maximum. Twisted-pair is recommended. I -t Communication Loss 2 cs 9 which support this feature) ARE51] (optional connection for panels FUTURE FEATURE Li 67V4.,I DN-6720 • 08/23104 - Page 5 of 6 ir 3.9K EOL Resistor (included) A2143-1O Connect modules to fisted compatible control panels only. I • Terminal wiring must be power limited. ii IJ 1 ING DO NOT MD( fire alarm initiating, supervisory, or security devices on the same circuit. DIAGRAMS DO NOTLOOPv,nre under terminals. Break wire run to provide supervision of connections. THIS PAGE:, Detectors must be UL listed compatible with module. Install detectors per manufacturers installation instructions. Power to the Interface module must be externally switched to reset the detectors. An FIRM-1 relay control module can be used to switch power from a standard power supply; see FIg. 7 below. V Fig. 6 FZM-1: Interface two-wire conventional defectors, NFPA Style B. Jc FROM Panel (+) or Previous Device Communication Line 32 VDC maximum. Twlstad-pair Is - recommended. (....) Listed Ba tie 4 D2' Backup 4 power supply. Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. V Fig. 7 FZM-1: Interface two-wire conventional detectors, NFPA Style D. (—) FROM Panel TO Next —) (+) or Previous De Device ice INTERFACE MODULE Communication Line d Twisted-pair is recommended. 3.9K EOL Resistor + at terminal Listed Battery Backup switched DC A2143-10 F power supply. ]1!°!49Opa,Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. V Fig. 8 FRM-1: Relay control module used to disconnect a power supply. (—) FROM Panel TO Next gDC)CIE or Previous Device DC POWER SUPPLY () Listed for Firs (—) Protection with Battery Backup (—) 4 (+) 4 Page 6 of 6— DN-6720 • 08123104 r?J DI CONTROL MODULE 011*1 7± 2 Communication Line 32 VDC maximum. TwIsted-pair is recommended. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:202 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FMM-1, FMM-101, FZM-1, FSM-101, FDM1* monitor modules and Models FCM- 1, FRM-1 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with Iistee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire a l a r m control units. Rev. 05-02-01 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verily correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable informatio n s o u r c e s . Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy I Program Manager The NB6-I2LX Addressable Manual Pull Station June 9, 2000 DN-6726 • H-240 NOTIFIER 1' FIRE SYSTEMS GENERAL The NOTIFIER NBG-12LX Is a state-of-the-art, dual-ac- tion (i.e., requires two motions to activate the station) pull station that Includes an addressable interface for any NOTIFIER intelligent control panel. Because the NBG- 12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. FEATURES Maintenance personnel can open station without causing an alarm condition. Built-In bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when In alarm. Handle latches In down position and the word "ACTI- VATED" appears to clearly indicate the station has been. operated. Captive screw terminals wire-ready for easy connection to SLC loop (acóepts Up to 12 AWG/3.25 mm2 wire). SemI-flush, mounts to a standard single-gang (2.125" [5.3975 cm] minimum depth), double-gang, or4".(1O.16 cm) square electrical box. Smooth dual-action design. Within ADA 5 lb. pull force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG-TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-12LX stations per loop on classic protocol systems (non-FlashScan). Up to 159 NBG-12LX stations per loop on FlashScan protocol systems. Dual-color LED blinks green for FlashScan systems. CONSTRUCTION Shell, door, and handle are molded of durable LEXAN (or polycarbonate equivalent) with a textured finish. OPERATION NBG-12LX Addressable Manual Pull Station with FlashScanTM Section: Intelligent/Addressable Devices U.S.. PATENTS PENDING O California U . /'\ State Fire C . L (c&) Marshal 7150-0028:199 LISTED S692 FM Approved Pushing In, then pulling down on the handle causes It to latch in the down/activated position. Once latched, the word 'ACTIVATED (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; closing the door automati- cally resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address set- tings (1-159 on FlashScan Systems, 1-99 on CLIP sys- tems). FlashScan Is a trademark of NOTIFIER. LEXAN® is a regis- tered trademark of GE Plastics, a subsidiary of General Electric Company. This document Is not intended 10 be used for installation purposes. We try to keep our product Information up-to-data and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more Information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 . _ OT1 F1 E R• 12 Clintonville Road, North(ord, Connecticut 06472 WEBB & MANUFAMMIS DN-6726 06/09/00 - Page 1 of F LI — -- ii $jiJ Terminal Connections I SLC (—) 2 SLC(+) Back of station without door. - TAI all I liI1i Detail of BREAKAWAY TAB* is 0 -- LED ROTARY DECIMAL SWITCHES "Remove tab to select addresses above 99 (FlashScan systems only). PRODUCT LINE INFORMATION ELECTRICAL SPECIFICATIONS Model Description NBG-12LX Dual-action addressable pull station. Includes key locking feature. SS-10 Surface backbox. BG-TR Optional trim ring. INSTALLATION The NBG-12LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm)square electrical outlet box, or will surface mount to the Model SB-b sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG-TR) maybe used. The BG-TR is usually needed for semi-flush mounting with 4" (10,16 cm) or double-gang boxes (not with single-gang boxes). Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 230 pA. ARCHITECTURAL! ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LE)(AN (or polycar- bonate equivalent) with clearly visible operating instruc- tions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger. Stations shall be suitable for surface mounting on matching backbox 58-10; or semi-flush mount- ing on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual. Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual sta- tions shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily Illuminated when in alarm. 1 I 1 I I I I I I I I I I I I I I Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Page 2 of - ON-6726• 06/09/00 CALIFORNIA DEPARTMENT OF FORESTRY & VIRL PJiis OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LA O B , N B G - 12-1-0, NBG-I2LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-I2WP, NB G - 1 2 L W P , N B G - 12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, tNBG-12LPS, NB G - 1 2 L P S P a n d NBG-12SP fire alarm pull boxes. The NBG-12 series is a dual action pull stati o n t h a t h a s normally open switch contacts. Models NBG-12LR and NBG-12LRA are intend e d f o r a g e n t releasing device. Refer to listee's data sheet for detailed product description a n d o p e r a t i o n a l considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and o r d i n a n c e s and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alar m c o n t r o l u n i t s . Models NBG-12WP, NBG-12LW, NBG-12W, NBG-12LWP, NBG-12LAO , N B G - 1 2 L 0 , N B G - 12LAOB and NBG-12LOB are intended for outdoor use when installed with M o d e l s W B B , S B - 1/0, or WP-10 back box. Refer to listee's Installation Instruction Manual for det a i l s . - Rev. 05-05-04 I This listing is based upon technical data submitted by the applicant. CSFM Fire Eng i n e e r i n g s t a f f h a s r e v i e w e d t h e t e s t r e s u l t s and/or other data but does not make an independent verification of any clai m s . T h i s l i s t i n g I s n o t a n e n d o r s e m e n t o r recommendation of the item listed. This listing should not be used to verify correct o p e r a t i o n a l r e q u i r e m e n t s o r i n s t a l l a t i o n I v criteria. Refer to listee's data sheet, installation instructions and/or other suita b l e i n f o r m a t i o n s o u r c e s . Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager i I I I • J §N0T1Fi=R FiRE SYSTEMS July 7, 2000 •. DN-1109 • E-200 PS Series Batteries Section: Power Supplies I / GENERAL Power-Sonic PS Series batteries provide secondary power forthe whole series of NOTIFIER fire alarm control panels. FEATURES Provide secondary power for control. panels. . Galled electrolyte. Sealed and maintenance-frees Overcharge protected. Extended shelf life. . Easy handling with leakproof construction. Ruggedly constructed, high-impact case (ABS, polystyrene, or. polypropylene depending on model). Long service life. . Compact design. . . CAPACITY Battery capacity, expressed In ampere-hours (AH), is the product of a discharge current and the length of time that the current is dis- charged. Batterie are rated according to their performance during 20 hours of discharge at a constant current The rated capacity of a battery Is determined by subjecting it to a constant discharge current for 20 hours at 68°F (20°C). After 20 hours the voltage across the terminals is measured. The discharge current which causes a reading of 1.72 volts per cell (5.16 V on a 6 V battery and 10.32 Von a 12 V battery) is called the rated current. This current multiplied by 20 is the rated capacity of the battery. APPLICATIONS Use the PS Series batteries to provide backup power for control panels. Select batteries based on current requirements for your system and the capacity of its charger. These batteries can be used over a temperature range of -76°F to +140°F (-60°C to +600C). CONSTRUCTION The sealed construction of the Pover-Sonic battery allows trouble- free, safe operation in any position. There is no need to add elec- trolyte, as gases generated during overcharge are recombined in a unique °Oxygen Cycle. The battery is ealed, leakproof, and maii- ten ance-free. The case is of high-impact materials with high resis- tance to chemicals and flammability. LISTED. MH14328 (S) L. SEALED RECHARGEABLE BATTERY •. Model 1`8.505 5 Volt 9.0 AN . . Corp .: ... .• •: S.. •.•. ... ••.•1 .,•-. .... The PS-695 Battery INSTALLATION. All panels have space reserved for batteries. See the appropriate panel installation manual for battery size restrictions. Typical inter- connection diagrams are shown in the literature accompanying each. control panel. I This document is not Intended to be used for Installation purposes. We try to keep our I anticipate all requirements. All specifications are subject to change without notice. For product Information up-to-date and accurate. We cannot coverall specific applicatona or an I IS09001 J more Information, contact.NOTIFIaR. Phone: (203) 484-7161 FAX :(203)484w7118 () NOTIFIER' .• One Fire-Uta Place. Northford, Connecticut 06472 .• 1NIN & MM1!FLCTURTh DNA 1O907IO7IO0 - Page 1 of 3 120% Effect of Temperature on Capa c/tv 100% 80% Of Co 60% 13 3. om 40% 20% 0% -20' -10' 0' 10, 20 30' 40' 50' 60 lloagrrs.wml Temperature (Degrees C.) I I I. I I I . I I. I I I I I, I I 1 I I I I * ... p. HEIGHT 1 BELOW 3.70 ± 0.08 Inches .: 00 (94±2rnm). HEIGHT 2 BELOW 3.86.± 0.08 Inches (96 ± 2 mm) I 1 BB- 17: Optional Battery Backbox A SEALED RECHARGEABLE BATTERY •. SIDE (mm: 368.3 W x 209.55 H x 120.65 D) . I" i . PS -I.27.0 MODEL u VIEW For remote mounting of two 12-volt . . PS-12180 batteries. 12 VOLT 7:0 'AMR HOUR .• I I' j 2.58 1 0.04 Inchis 11Odlmttif Battery -:'CHG-120 r data sheet for . . . ENGINEERING SPECIFICATIONS . The fire control panel shall be equipped with secondary power provided by gelled-electrolyte batteries. The batteries shall be maintenance-free and shall be capable of powering the system In a manner and for a length of time determined by the governingregulations and the authority having Jurisdiction. Nominal Discharge DIMENSIONS Capacity Current Height over Nominal @ @ Width Voltage 20 hr. rate 20 hr. rate _Height _terminal _Weight _Depth MODEL V . A.H. mA in. mm. In. mm. In. mm. in. mm. lbs. kg. PS-695 6 9.5 475 4.25 108 2,75 70 5.54 141 5.54 141 4.9 2.2 P5-1250 12 5.0 250 3.54 90 2.76 70 4.02 102 421 107 4.1 1.9 PS-1270 12 7.0 325 5.94 151 2.56 65 3.70 94 3.86 98 5.7 2.6 PS42120 12 12 600 5.94 151 3.86 98 3.70 94 3.86 98 8.8 4.0 PS-12180 12 18 875 7.13 181 2.99 76 6.57 167 6.57 167 12.8 5.8 P5-12250 12 25 1300 6.89 175 6.54 166 4.92 1 125 4.92 125 18.7 8.5 PS-12550 12 55 3000 10.25 260 6.60 168 8.20 208 9.45 240 39.7 18.0 PS-121000 12 100 5000 12.00 305 6.60. 168 8.20 208 9.45 240 65.7 29.8 110911.Ibi Characteristic Discharge Curves 6.5 L13 6.011 cc 2 CM 5.5 11 0.175C 0.5C 4.5 L9 5OL1O hI 0 _J_ 3C _ o.2c 4.0L8 I 1 2 3 5 10 2030 60 2 3 5 10 2030 110grf1•UI nnutes hours Discharge Time © 20C (68'F) Page 2o(3 - DN-1109•07/07100 13.0 V 10.0v 9.0v 8.0 V 100% 90 0 80°i 70 CD °A CD 60% 40% 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) 0% 0 PS. 121000 RECHARGEABLE BATTERY: APPLICATIONS AND CHARGING CYCLE APPLICATIONS: Limit initial current to 20A. Charge until batteryyoltage (under charge) reaches 14.40 to 14.70 volts at 68°F (200C). Hold at 14.40 to 14.70 volts until current drops to approximately 1000 mA. Battery Is fully charged under these conditiOns, and charger should either be disconnected or switched to ffloat" voltage. "FLOAT' OR "STAND-BY" SERVICE: Hold battery across constant voltage source or 13.50 to 13,80 volts continu-ously. When held at this voltage, the battery will seek its own current level and maintain Itself In a fully charged position. NOTE: Due to the self-discharge characteristics of this type of battery, It Is Imperative that the battery be charged after six to nine months of storage, otherwise permanent loss of capacity might result from sulfation, I I I I I I I I I I I PS-121000 Shelf-Life and Storage PS-121000 Discharge Characteristics ON-i 109- 07107/00 - Page 3 of 3 1.2 2.4 6 12 24 36481 2 4 6810 20 40 MINUTES X HOURS Discharge Time Models Available Strobes Red çC White S1224MC- SI224MCW S1224M0P S1224MCPW S1224MCK S1224MCSP Mt Horn/Strobesf e4rfr Red White P12241VIC ' P1224MCW P1224MCP P1224MCPW P1224MCK P1224MCSP Horns Red White H12/24 H12/24W H12/24K Product Overview Operates on either 12V or 24V Widest range of candela options: 12V: 15 and 15/75 candela 24V: 15, 15/75 30, 75, 110 candela Easy candela selection Lower current draw Easy DIP switch selection for horn options Easy mounting with QuickClickTM Synchronizable with MDL Sync .CircuitTM module Meets UL1971, NFPA72, and ADA signaling requirements All strobe and horn/strobe models incorporate a new patent-pending voltage booster design that has a more consistent flash bulb voltage over the range of candela selections. The benefit to the customer is a high quality strobe device. I LISTED CS5495602NK17954 55512 CS549V702NItI375I. S4011 I .MEA approved 7130.1209:222 '° 122.02-E 71301209223 30141.50 12602-5 I I SpectrAiert6 Selectable Output Horns, Strobes, and Horn/Strobes offer enhanced fee- tures that Include the widest range of candela options available and the capability to recognize and self-adjust for either 12 or 24 volt operation. With an overall featwe set that combines performance, installation ease, ftexibility, and a consistent, aesthetically pleasing appearance, the SpectrAlert Selectable Cut ut devices provide both the innovation and efficiency synonymous with the SiectrAlert name. Performance. SpectrAlert selectable output wall-11101nt horns, strobes, and horn/strobe; offer key performance features long associated with the SpectrAlert name. The select- able candela strobes and horn/strobes offer average current draws that are not only lower than conventional fixed-candela SpcctrAlert products, but also lower than similar selectable candela products. By consuming less current, the ability to :onnect even more devices per loop is possible, resulting in a lower installed cost. Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the same installation-friendly features synonymous with the SpectrAlert name, such as the option of 2- and 4-wire operation; the ability to use standard size backboxes with no encroachment into the box; and universal mounting incorporating the labor-saving Q uickClick' feature. Such labor-savings features make wire connections simple and fast, further reducing installed cost. Flexibility. SpectrAlert selectable output strobes and F c-rn/strobes oIfe the broadest range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either 12V or 24V with no setting required; the device recognizes and self-adjusts to the correct current automatically. Temporal 3 or Continuous tone opoons continue to be available, in either an Electrornechanica. or 3k1-lz pattern. Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate the same stylish, low profile design of the conventional SpectrAlert products, for a con- sistent and aesthetically pleasing appearance across the entire product line. Engineering Specifications General SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 41 x 4" x 11/21 back box or a single gang 2" x 4' x 1/s' back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert prod- ucts, when used in conjunction with the accessory Sync-Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices shall have an operating voltage range of 9-17.5 volts. 24-volt rated devices shall have an operating voltage range or 17-33 volts. SpectrAlert products shall have an operating temperature of 32° to 120°F and operate from a regulated DC or full wave rectified, unfiltered power supply. Strobe Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall con- sist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination Horn/Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/ strobe models shall operate on a coded or non-coded power sup- ply (the strobe must be powered continuously). Synchronization Module Module shall be a System Sensor Sync-Circuit listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal 3. Also, the module shall silence the horns on horn! strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 411/16° * 411/161 x 2/8° back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply. I I I I I El I I Specifications Walk Test SpectrAlert horn/strobe and horn only work on 'walk tests' with time dura- tions of 4 seconds or greater Input Terminals 12 to 18 AWG Dimensions Strobe and horn/strobe with universal plate 5" x 5/a' x 215/is' Strobe and horn/strobe with small footprint plate 3/s' x 5/a' x 2/18' Horn with universal mounting plate 5' x 5/a° x 1/ie' Horn without mounting plate 215/161 x 55/18'x 1/1e' Weight, horn only 7.2 oz. Weight, strobe and horn/strobe 8.8 oz. Mounting 4 x , 11/' or 2° x 4" x standard boxes Indoor Operating Temperature 32°F to 120°F (0°C to 49°C) Maximum humidity 95% as tested per UL464 Operating Temperature Weatherproof (horn and horn/strobes) 32°F to 150°F(O°C to 66°C) (outdoor strobe only) —40°F to 158°F (-40°C to 70°C) ULC Canadian Models —40°C to 66°C Voltages 12 or 24VDC and FWR unfiltered Operating voltage range" 12V: 8-17.5V; 24V: 16-33V Operating voltage range (with Sync-Circuit module, MDL) 12V: 9-17.5V; 24V: 17-33V Note for Strobes: Do not exceed; 1) 16-33 or 8-175 voltage range limit; 2) maximum number of 70 strobe lights when connecting the MDL Sync module with a maximum line impedance of 4 ohms per loop and; 3) maximum line impedance as required by the fire alarm control manufacturer U.S. Patent Numbers 5,593,569 5,914,665 6,049,446 I U I Eli I T H I I Viewing % Candela Selections Selectable Horn Tones For strobe candela selection, adjust slide switch located on the Temporal Low Volume rear of the product while watching the viewing window on the side of the reflector. Electromechanical 3000 Hz Interrupted Electromechanical Permissible Candela Settings i 3000 Hz Interrupted Candela Operating Voltage Non-Temporal Low Volume Electromechanical Setting 12V 24V 3000 Hz Interrupted 15 OK OK High Volume Electromechanical 15/75 OK OK 3000 Hz Interrupted 30 OK 75 OK DIP Switch Operation 110 OK Factory OFF ON Default jDIP Switch Low Ji_jjJ High _ raI Temporal II I Non-Temporal ( !o Electromech. II I 3000Hz oJ I Base (rear) LEI AD 0-00 SpectrAlert Current Draw FWR Operating DC Operating Current- Current-Strobe Strobe Candela (mA RMS) (mA RMS) Series Setting 12V 24V 12V 24V I FWR Operating Current-Horn (mA RMS) DC Operating Current-Horn (mA RMS) Horn Audibility (dBA) 12V 24V 12V 24V S1224MC 15 112 64 127 59 Strobes 15/75 135 74 127 69 30 1 93 1 90 75 158 160 110 208 209 1 P1224MC 15 112 64 127 59 1 Horn/Strobes 15/75 1 135 1 74 127 1 69 1 45.7 57.5 44.4 57 75 45.7 1 57.5 44.4 57 75 30 93 90 75 158 160 57.5 57 75 57.5 57 75 110 208 209 57.5 57 75 12/24 Horns 45.7 57.5 1 44.4 57 75 SpectrAlert Mounting and Operation Typical weatherproof mounting with universal plate WBB ,- Plate r— #8-38 x hr Fiat Head Screw (4 total) A012000 Gasket Conduit Entrance Paper Uner For Plate Gasket SpectrAlert Ordering Information Model jDescrlption P1224MC Selectable Output Horn/Strobe, 12/24 volt, red P1224MCW Selectable Output Horn/Strobe, 12/24 volt, white PI224MCP Selectable Output Horn/Strobe, 12/24 volt, red, plain housing P1224MCPW Selectable Output Horn/Strobe, 12/24 volt, white, plain housing P1224MCK Selectable Output Horn/Strobe, 12/24 volt, red, weatherproof P1224MCSP Selectable Output Horn/Strobe, 12/24 volt, red, FUEGO' housing S1224MC Selectable Output Strobe, 12/24 volt, red S1224MCW Selectable Output Strobe, 12/24 volt, white S1224MCP Selectable Output Strobe, 12/24 volt, red, plain housing SI224MCPW Selectable Output Strobe, 12/24 volt, white, plain housing S1224MCK Selectable Output Strobe, 12/24 volt, red, weatherproof S1224MCSP Selectable Output Strobe, 12/24 volt, red, 'FUEGO' housing Model Description H12/24 Horn, 12/24 volt, red H12/24W Horn, 12/24 volt, white H12/241( Horn, 12/24 volt, red, weatherproof Accessories MDL Sync.Circuit Module, red MDLW Sync'Circuit Module, white MDLA Sync-Circuit Module, red, Canadian model MDLWA Sync'Circuit Module, white, Canadian model S.MP Smell Footprint Mounting Plate, red, for single- gang back box S-MPW Small Footprint Mounting Plate, white, for single- gang back box BBS Surface Mount Back Box Skirt, red BBSW Surface Mount Back Box Skirt, white D-MP Universal Mounting Plate (replacement), red D-MPW Universal Mounting Plate (replacement), white WBB Weatherproof Back Box Notes Agency Listings - Indoor models: UL, ULC FM, CSFM, MBA. Weatherproof models: UI., CSFM (strobe only), MEA, ULC. All of these SpccerAlcrt products are designed for wall mount only. All weatherproof models D= use weatherproof back box model WBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). Howeve; it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15175 candela strobes or horn/ strobes are recommended for 20' x 20' rooms or less. System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in china System Sensor - For East 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.524.6253 Ph: 85.22.191.9003 St. Charles, II. 60174 Pa: 905 .812.0771 Pa: 86.29.524.6259 Fx: 85.22.736.6580 Ph: 800/SENSOR 2 System sensor Europe System Sensor In Singapore System Sensor - Australia Pa: 630/377.6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Documents.on-Demand Pa: 44.1403.891921 Pa: 65.6273.2610 Fx: 613.54.281.172 800/736-7672x3 www.systemsensor.com System Sensor - India Ph: 91.124.237.1770 x.2700 Fx: 91.124.237.3118 System Sensor - Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 0 2004 9/stern Sensor. The company reserves the right to change product specifications without notice. A05.0325-003.5/04.11200 CALIFORNIA DEPARTMENT OF FORSTR? & FIRE PYi Et, i'TD1 OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1209:222 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: System Sensor, 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6674 FAX (630) 377-7245 DESIGN: Models S1224MC synchronized strobe lights (when used with MDL Sync module) with selectable candela. Units may be followed by the suffix SP *indicating marking of the word ¶UEGO', *or the suffix P indicating plain housing with no lettering, *may be followed by letter W indicating color white, *otherwise it is red. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC/FWR 12/24 VDC/FWR Selectable lscd, 15/75cd 24 VDC/FWR Selectable 30cd, 75cd, or 110cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall mount only. Refer to listee's Installation Instruction Manual for details. *Rev. 02-24-04 I ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sauces. 1 Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE V LISTING No. 7135-1209:223 Page 1 of 1 CATEGORY: Audible Devices LISTEE: System Sensor, 3825 Ohio Ave, St Charles IL 60174 Contact Trish Linhart (630) 377-6674 FAX (630) 377-7245 DESIGN: Models P1224MG, P1224MCW, P1224MCSP, P1224MCSPW, P1224MCP, P1224McPw P1224MCK. and PI224MCWK combination horn/strobes with selectable candela. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 8-33 VDC/FWR 12/24 VDC/FWR Selectable :l5cd, 15/75cd 24 VDC/FWR Selectable: 30cd, 75cd, llOcd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. These sounder/strobe combination units are not intended for field assembly. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as horn strobes for use with separately listed compatible fire alarm control units. Suitable for the hearing impaired application. For wall mount and indoor use only. Models with suffix K' are suitable for extended indoor operation temperatures 32 to 150 F (0 to 66 °C) and have NEMA type 3R enclosure rating for outdoor use. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacu a t i o n Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to manufacturer's Installation Manual for details. Rev. 02-24-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions end/or other suitable inform a t i o n s o s c e s . Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FInE POTi., iIi OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1209:143 Page 1 of 1 CATEGORY: Audible Devices LISTEE: System Sensor, 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6674 Fax (630) 377-7245 DESIGN: Models PA400R, PA40013, PA400W, APA-451, H12124, H12/24W, H12/24K, H 0 1 2 1 2 4 , HC12124W and HC12124K sounders. Suffix "W' indicating white color and suffix K ' indicating extended indoor operating temperature range of 32°F to 1500 F and a NEMA 3R enclosure rating. Models PA400R, PA400B and PA400W may have suf f i x " F e f o r l e t t e r FIRE printed on unit Models H12J24, H12/24W, HC12124, HC12124K and H C 1 2 1 2 4 W a r e not suitable for public mode fire alarm service when used at low volume on 12V co n t r o l panels. Refer to listee's data sheet for additional detailed product description a n d operational considerations. RATING: PA Series: 12 or 30 VDC APA Series: 15- 32 VDC H12124 or HC 12124 Series: 10.5- 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72. applicable c o d e s & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm co n t r o l u n i t s . For indoor use only. Series H12124 and HC12124 can generate the Temporal Patte r n signal. If series APA or PA are required to produce a distinctive three-pulse Temp o r a l Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with N F P A 7 2 , 1999 Edition, they must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for deta i l s . NOTE: Formerly 7135-0087:132 I Rev. 06-16-2003 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineerin g s t a f f h a s r e v i e w e d t h e t e s t r e s u l t s and/or other data but does not make an independent verification of any claims. This l i s t i n g is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct o p e r a t i o n a l r e q u i r e m e n t s o r i n s t a l l a t i o n UJJ criteria. Refer to listee's data sheet, installation instructions and/or other suitable informa t i o n s o u r c e s . I Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager I (O NOTIFIER" A Pittway Company July 9, 1998 J-200 I KMS Series Alarm Bells Section: Audio/Visual Appliances I California / \ State Fire ye') Marshal 7135-0028:117 0M6A4.AY GENERAL The NOTIFiER KMS Series bells are low-current, audible signaling devices for use in fire alarm systems or other signaling applications. S748 CS47021 FEATURES Under-dome design. Available in three gong sizes (6 , 8u, and 10" diam- eter). Low operating current. Low "kick" current o Indoor/outdoor installation. Mount to standard 4" square electrical box. Complies with UL 864. OPERATION The KMS Series bells use a low-current, high efficiency DC motor to drive the striker. All DC models are polar- ized for use with supervision circuitry. The operating mechanism is completely enclosed in a cast alumi- num base. APPLICATIONS KMS Series bells are ideally suited for almost any kind of alarm signaling application. They can be used in schools, factories, office buildings, or private residences. Their low current consumption means additional sav- ings on standby power. CONSTRUCTION Each bell gong is made of steel finished in red enamel The striker is also made of steel, and the mechanism housing is made of cast aluminum. Optional backboxes are of steel finished with red enamel to match the gong. INSTALLATION Bells may be installed on a wall surface or semi-flush. A weatherproof backbox (WBB) also permits installa- tion on an exterior wall surface. BSA 1070-80-SA This document is not intended to be used for installation purposes. We try to keep our I I product information up-to-date and accurate. We cannot cover all specific applications lSQ9001 or anticipate all requirements. All specifications are subject to change without notice. i Engineering and Manufacturing For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX (203)484-7118 Quality System Certified to () N OTI Fl E l 12 Clintonville Road, Northford, Connecticut 06472 International Standard ISO-9001 DN-2252 - Page 1 of 2 PRODUCT LINE INFORMATION Model Number Gong Size SPL Measurement at 10 ft (3.048 mr Rated Input Voltage Rated Cunnt (mA) Minimum Starting Voltage KMS-6-24 6" (15.24 cm) 85 dB 24 VDC 30 12 VDC KMS-8-24 8" (20.32 cm) 85 dB 24 VDC 30 12 VDC KMS-10-24 10" (25.40 cm) 85 dB 24 VDC 30 12 VDC WBB Surface-mount weatherproof backbox, metal, red. BB-R Standard 4" square electrical backbox -red enamel finish. SFP-R Semifivah plate, mounting trim, metal, red. MP-SF!R Semillush plate, mounting trim, plastic, red. Notes: * Sound Pressure Level (SPL) measured in accordance with UL Standard 464. UL Standard 464 requires that: The units be measured in a reverberant room qualified for pure tones under the methods for Determination of Sound Power Levels of Small Sources in Reverberation Rooms, ANSI Si .21- 1972. The units be capable of providing a sound out- put of not less than the sound level provided by an omnidirectional source having an A- weighted sound pressure level equal to the level specified on the unit marking and not less than 75 decibels in any case. 6-inch bells 2-19!32 (6.59 cm) 8-inch and 10-inch bells 3-118" (7.94 cm)) Page 2of2 - DN-2252 07/10/2005 14:12 8585373433 TRI SIGNAL PAGE 02 Name of protected property . Address: 9&/ P1+i.ofl, Representative of protected p Authority having Jurisdiction: Mdrttelephone number: - FIRE ALARM SYSTEM RECORD OF COMPLETION Oc.'-'7/ ,4AJ/fl4/- 2TA Org6lld(le Name/chi.. Installer TRIS/6fr4' /W/-!ATJLW Supplier Service organization _TRJ-i'/AJA L /4/TA Location ofrecord (es-built) drawings: '6f'2__V/k XCIL,1 Location of operation and maintenance manuala: £4 ,P7,E AS / Location of test reports: S,4/4F A-5 AffPVE A contract for tact and inspection in accordance with NFPA standard(n) Contract No(a) _____________________ Effective date: Pspr.u.tuit. Dc DD /iA.D I :o ,(,NOLL 572. L/7e Expiration data: Syaten Software Operating eyOten (executive) software re'vieiun level(s): F1 -7.0/ Site-specific software revision data: 23 - 05 (c)Ren completed by NO4N . RH/I FlY T/?i S/41L )NT,RAT/ (?lrm l.Typ.(s) of System or Service NFPA72, Chapter 6—Lees] If alum to transmitted to location(a) off promises, list where received: NFPi' 72, Chapter 6— Remote Station Telephone numbers of the organization receiving alarm. Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service cconwunicalions centers or others, indicate location and telephone numbers of the argization receiving alarm:_ Indicate how alarm is retransmitted: NFPA 72, Chapter S — Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, Indicate location and telephone numbers of the organization receiving alarm: - / Indicate how alarm Is retransmitted: - - _LNFPA 72 Cbepir S - Central Station Prime contractor: — Central otation 1ocation .S3 — OVE. 1. '4111) AV• S D., C1 * /3 (NPA 7,1 04 07/18/2005 14:12 8585373433 TRI SIGNAL PAGE 03 Moans of tranemJpion of signals frora the protected premises to the central station: MaCallah Multrpie'c One-way radio Digital alarm communicator Two-way radio Others Means of transmission of aiarme to the public fire service communications center: (a) 7E4PHOA1t LIVES 7Z (movE L/AJES System location:_29/ P4oMAIk ,4i,??ocr• /Z). 64 ALSBAbi j, 92 ay__ _NPA 72. Chapter 9 —M'dllary Indicate type of connection: Local energy - Shunt _____Parallel telephone Location of telephone ntunber for receipt of signals: - Record of System Installation (Fill out after installation is complete and wising is checked for opens, shorts, ground faults, and Improper branching, but prior to conducting operational acceptance teeth.) This system has been installed in accordance with The NFPA standartio as shown below, was inspected by ________ on , includes the devicca shown n 5 and 8, and has been in service since ...NFPA 72, Chapters (j) () 5 8 6) 8 9 10 11 (circle all that apply) 70, National Electrical Code, Article 760 .j(Manuacturers instructions _Other Signed: _tIój(::::i1ci Date: Orgw,zaticn: i-r1 - 5/I-A/AL /JTE6A'Ay,c,V 3. Record of System Operation Doitatinn in accordance with Inspection Testing Form, Figure 10.6.2.8 Is attached _______________ All operational features and functions c,fthi system were tested by RHW data _6 ' and found to be operating properly in accordance with the requirement* of: J1FPA 72, Chapters £V () ) 5 6 0 8 9 10 11 (circle all that apply) ._'NFPA 70, National Electrical Code, Article 760 ......."Manufacturer's instructions Othcr(cpecify): -- Signed Organizatioti:_TIck SIHIA L ___________________________ SignalinØ Line Circuits Quantity and clean of signaling line circuits connected tosyctern (oee NFPA 73, Table 6.6.1): Quantity Style: Class: R (NFPA 72,2 G 4) 07/18/2885 14:12 8585373433 TRI SIGNAL PAGE 04 , . S. Alarm-InlUatirig Devices and CIrcuIa Quantity and clse of initiating device circuits (Ne NFI'A 72, Table 8.5): Quantity :1 Sty Li Clase:. MANUAL Manual stations Notcoded . Transmitters — Combination manual fire alarm and guard's tour coded stations - Coded________ Addressable /S Coverage: Complete _________________________ partial_ Selective Nonrequired - (a) Smoke &etoctore________ Ion— Photo 2. M&reeeable________ (b) Duct deteetore_______ Ion _ Photo_____ Addressable () Heat detsre_______ FT______ RR_ FTfRR_...._ BC______ Mdreaeeble______ (d) Sprinkler watorilow indicators: Tianamittam_______ Noucaded Coded - Addressable I (a) The alarm verification feature is disabled______ or enabled , changed from ______ seconds to ______ eacnnde. (1) Other (list): - 6. Superveory Slgnal.InItIatlng Devicea and Circuits (use blanks to Indicate quantity of devices) GUARD'S TOUR W— Coded stations (b)_Noncoded stations (c) - Compulsory guard's tour system comprised of transmitter statioas and intermediate stations Note: Combination devices an recorded wider 5(b) Manual, and 6(a), Guard's Tour. SPRINKLER SYSTEM Check if provided (a)_Valve supervisory nwitcha (b)—Building temperature points (c)_Site water temperature points (d)_ Site water supply level points Electric fire pump: —Fire pump power ___ Fire pump running (g).._..._. Phase reversal Engine-driven fire pump: (h)__. Selector in auto position Engine or control panel trouble _Fire pump running ENCDE-Dl1VEN GENERATOR: (a)_... Selector in auto poetiox (b)_ Control panel trouble (c)—_Ttansfee switches (d)— Engine running Other supervisory function(s) (specie): (NFPA72,n 01 4) 07/18/2005 14:12 8585373433 TRI SIGNAL PAGE 05 7. AnnunCie 0 Nwber _ Type: o S. Alarm Notification Appliancea and Circuits NFPA 72, Chapter 6— Emergency Voice)arm service Quantity of voice/alarm channala: - Sjnle: pleL Quantity of epeakara inotalled: Quantity of e Quantity of telephonea or telephone jacks included in aytem: 4 Quantity and the class of notification appliance cirvuita connected to syate (ue NFPA 72, Table 67): Quantitr Style:___________ Claes: _8 Typee and quantities of notification appliances inat&Ied: Bello - With Vieible Skora_____________ With VIaiblo________________ Home 3 WithVieible_J S (4) Chimes _ With Vjoible (a) Other: ___________________ With isible (t) Vitnhie appliances without audible: 9. System Power Supplies re Alarm Control Panel: Nominal voltaga: J2 OVA ( _50/60 Currottratinir 0 ,4J ' Ovorcurrent Type., 20 14)P _1(— Current rating:._-0_4111' Location: _ P1 Seconay (standb): Storage battery: id..V ) ,npiwur rating: Calculated capacity to drive eystam, in hours: Engine.driven generator dedicated to fire alarm Location of fuel atorage: - Emergency ayatam used as backup to primary power Emergency eyatum de'cribad in NFPA 70, Article 700: __________________________________ _ _ _ _ _ _ _ _ _ _ _ 10. Comments Frequency of routine teate and inspections. if other than in accordance with the referenced NFPA etendnrd(e): System deviations from, the referenced NFPA standard(o) are: 4. jfl4 PoTh'C 71}i 61 7 -1-0-3 Ir&omm Illup -k-. "ta-r '> 7-/- OS (.IBr,edl 101 FORM a.r'.Ia. corn play (IIfl.) (dOla) (eigned) for oøntrei etatlon (tide) (dale) Upon completion of the system(e) satisfactory test(a) witneoged (if required by the authority havin9jurisdidionY x (Ilealdi ,oDIllflhlIIvQOOKO pUIhrIty havlof IU,aIIlIIo (11111) W OS (NFPA 72.4 of 4)