Loading...
HomeMy WebLinkAbout2282 FARADAY AVE; ; FA020021; Permit9/30/2020 FA020021 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2282 FARADAY AV Permit Type: FALARM Parcel No: 2120613300 Lot #: 0 Reference No.: PC #: Project Title: ISIS Permit No: FA020021 Status: ISSUED Applied 6/13/2002 Approved: 8/26/2002 Issued: 8/26/2002 Inspector: Applicant: Owner: ISIS'PHARMACEUTICALS INC 2280 FARADAY AV CARLSBAD CA Fees ($) Add'l Fees ($) I Total ($) Balance ($) 275 J 0 275 0 1/1 ff4?7r F,4O2 o02J ISIS PHARMACEUTICALS LIMP LABORATORY 2282 FARADAY AVE. CARLSBAD, CA 92008 4.! FIRE ALARM SYSTEM EQUIPMENT SUBMITTAL June 6, 2002 VOLUME 1 OF 1 ISIS PHARMACEUTICALS GMP LABORATORY FIRE ALARM SYSTEM EQUIPMENT SUBMITTAL BILL OF MATERIAL DESCRIPTION Fire Alarm Control Panel Cabinet A3 Digital Communicator Liquid Crystal Display Intelligent Photo Elec. Det. Intelligent Heat Det. LASER Smoke Det. Smoke/Heat Det. Base Control Module Monitor Module Addressable/Pull Station Duct Detector Explosion-Proof Pull Station Explosion-Proof Smoke Det. Power Supply Horn Strobes Strobes Explosion Proof Strobe Explosion Proof Horn Lot Interior Fire Cable MANUFACTURER Notifier Notifier Notifier Notifier Notifier Notifier Notifier Notifier Notifier Notifier Notifier Notifier Notifier Notifier Wheelock Wheelock Wheelock Harrington Harrington West Penn MODEL AFP-400 CAB-A3 UDACT LCD-80T FSP-751 FST-75 1 FSL-751 B710LP FRM- 1 FMM-1 NBG-12LX FSD-75 IP XAL-53 30-3003 PS-12/24-8 AS24**CFR RSS24**CFR HEPS-24-C-C 879DEX-G 1 60991B 60993B 980 LISTING # 7170-0028:181 7165-0028:181 7300-0028:174 7120-0028:156 7272-0028:206 7270-0028:196 7272-0028:218 7300-0028:173 7300-0028:202 7170-0028:202 7150-0028:199 3240-0028:205 7150-1439:100 ISO-83/2031X 7315-0785:149 7125-0785:131 7125-0785:141 7300-0476:115 7135-1388:133 7161-0859:101 I July 6, 2001 DN-5262• S 0 NOTIFIER® GENERAL The AFP-300 and AFP-400 are compact, cost-effective, in- telligent fire alarm control panels with a total capacity of up to 563 points and an extensive list of powerful features. The AFP-300/400 integrates conventional output circuits, such as notification, telephone, and speakers, with the intelligent features of one or two signaling line circuits (SLC) and 198 or 396 intelligent/addressable points. FEATURES One loop (AFP-300) or two loops (AFP-400) Style 4, 6 or 7. 198 intelligent devices per loop (99 intelligent detectors and 99 intelligent modules). 396 intelligent device capacity on the AFP-400; 198 on the AFP-300. VIEW®, HARSI-FM, Advanced Multi-Sensor (AMS) op-tions. Up to 68 internal circuits/relays, plus 99 programmable zone output relays for a total capacity of 563 points. Four integral Notification Appliance (signal) Circuits (NACs), Style Z or Y (Class A or B). 6.0 A power supply, plus 6.0 A expanders. NACs may be programmed for Steady, March Time, Tem- poral, California code, or Canadian Two-Stage. Modified California code, pulsed on time. Tornado Warning activates different Notification Appli- ance Circuit code. Alarm, Trouble, Supervisory, and Security relays, stan-dard. Peer-to-peer network-ready. Intelligent features: V Manual sensitivity adjustment - 9 levels. V Pre-alarm A WACSTM —9 levels. V Day/Night automatic sensitivity adjustment. V Drift compensation (U.S. Patent Pending). V Multi-detector algorithm involves nearby detectors in alarm decision (patent pending). V Auto detector test (meets NFPA 72). V Maintenance alert (two levels). V Self-optimizing pre-alarm adjusts pre-alarm level to environment automatically. V Activate local sounder base on pre-alarm. V LED blink control for sleeping areas. V Automatic device type check. V Trouble after 20 detector verifications. Releasing features: ..' Ten independent hazards. V Sophisticated cross-zone (three options). V Delay timer and Discharge timers (adjustable). V Abort (four options). AFP-300 and AFP-400 Analog Fire Panels Section: Intelligent Fire Alarm Control Panels California State Fire Marshal 7170-0028:182 LISTED CS118/733 7165-0028:181 S635 City of M EA Chicago 17-96-E (AFP-400) Approved CLASS 1: 1291E 17-96-E Vol. Il (AFP-300) CLASS 2: 1729E Sensitivity windows: V ION - 0.5 to 2.5%/foot obscuration. V PHOTO - 0.5 to 2.359,/foot obscuration. V MULTI-SENSOR - 0.71 to 4.0.1/foot obscuration. V VIEW® - 0.03 to 1.091o/foot obscuration. Low-pressure CO2 support: V Expanded soak timer - 0 to 9999 seconds. V Manual release delay (10 seconds) type ID. V "Second shot" monitor module type ID. V Triple-coded notification circuit type ID. Voice and telephone features: V Solid state message generation. V Hard-wired voice control module options (System 5000 class modules). V Distributed voice options (XP transponders). V Firefighter telephone option. V 30- to 120-watt high-efficiency amplifier. V Backup tone generator and amplifier option. V Dual channel option. Telephone control module type ID. I This document is not intended to be used for installation purposes. We try to keep our I product information up-to-date and accurate. We cannot cover all specific applications or ISO 9001 anticipate all requirements. All specifications are subject to change without notice. I For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 MOM= N OTI Fl E IM6 12 Clintonville Road, Northford, Connecticut 06472 ENGINEERING & MANUFACTURING Made in the U.S.A. DN-5262 • 07/06/01 - Page 1 of 10 FEATURES, cenlinued . • Optional UDACT, 396-channel digital alarm communi- cator transmitter with AC fail delay. 80-character displays (up to 32) for remote annuncia- tion. ACS annunciators (EIA-485), including LDM custom. Two-wire detector interface provides compatibility with many manufacturers detectors for retrofit applications. Integral printer interface (80-column and 40-column print- ers). Integral 80-character LCD display, backlit (2 lines x 40 characters). Field-programmable on panel or on PC, with program check, compare, simulate. Full QWERTY keypad behind flip-down door. Autoprogramming and Walk Test. Identifies two devices set to the same address. History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. Programmable waterfiow or supervisory selection per point. Programmable combo zone - allows tamper and waterflow detectors to connect to a common monitor module. - Alarm Verification selection per point, with tally. Verification Trouble counter. Trouble indication after a detector verifies 20 times. Programmable Positive Alarm Sequence (PAS) Presignal .• per NFPA 72. Silence inhibit and Auto Silence timer options. Programmable non-alarm points for lower priority func- tions. Remote ACK/Silence/Reset/Drill via addressable mod- ules. Maintenance Reports may be sorted via PC by compen- sation value (dirty detector), peak alarm value, or ad- dress. Automatic time control functions, with holiday excep- tions. Dual rate charger for up to 90 hours of standby power. Rapid poll algorithm for manual stations. Responds to alarm/activatioh in less than three seconds. SLC loop maximum length 10,000 feet (3,048 m) @ 12 AWG (3.25 mm2). Surface Mount Technology (SMT) electronics. High-speed RISC 16-bit microprocessor. Extensive built-in transient protection. L-] Page 2 of 10 - DN-5262 • 07/06/01 0 I M"', ~ L_ FMM-1 FCM-1 -t XP Transponder IDC NAG FMM-1 FCM-1 '4r XP Transponder IDC NAC - U U P fI At .rir—r r.rl ACM-8R Relay Control ACMIAEM-I6AT LED Annunciator Optional 396 channel UDACT Universal Digital Alarm Communicator Transmitter I 0 0 0 I 0 L __ J Hi E . _T I 0 Cj LDM-32 Custom Graphics Dual phone lines to Central Station RS-232 PRN Printer CRT-2 Terminal r~ SAMPLE SYSTEM BLOCK DIAGRAM SLC Intelligent Loop I FS751 FS751 FST-751 - DEVICES - - - U Ion Photo Thermal — — — — — — — — — — - NBG-12LX - Fixed TO SLC Intelligent Loop 2 32 LCD80 Remote IX-751 DEVICES 11 Photo/ FST-751R Advanced — — — — — — — — — — - NBG-12LX RS-485 Thmal Rt!J Multi-Sensor 4 - - 4 _____ 1- -------n• Up to68fully No - programmable output circuits rn I ______ -nraJ dJ 4 ' . Id1tt1 AFP-400 shown in CAB-C3 with voice alarm system RS-485 640 annunciator/control points ii ------------ --------------------------I ---------------------------------- 80-Character (2 x 40) Back-Lit LCD Display - Status LED's - Control Switches Programming Keypad Flip-Down Door (covers the programming keypad) Slide-in Label EPROM The CPU-300/400 EIA-232 EIA-485 Port SLC Loop #1 ElA-232 Terminal Port Terminal Mode' ElA-485 Port (Style 4, 6, or 7) SLC Loop #2 (AFP-400 only) Printer Port (Style 4,6, or 7) The MPS-400 Main Power Supply 2 non-resettable Resettable 24 VDC circuits 24 VDC @ rated 1:25 amps 1.25 amps* each* '. I (Field Selectable) r2- Battery (12-60 Aft) Form-C Alarm, Trouble, Supervisory, and Security contacts. (3 amps @ 30 VDC) (Note: Supervisory and Security contacts can be converted to alarm contacts.) NAC or Releasing circuits 1 & 2. Class A or Class B, if[R 4 24 VDC @2.5 _____ amps each.* : NAC or Releasing Circuits 3 & 4. Class A or B, 24 VDC @ 2.5 amps each.- Statusifrouble LEDs *The I power supply. Total power, I including internal modules, I I cannot exceed 6 amps. a UZCCoderinput ____ d] rf___________ri Door Tamper Switch (STS-200) Meter Module Option (MPM-2) Page 4 of 10 - DN-5262 • 07/06/01 Optional Transmitter module (4XTM connector). AWACSTM Advanced Warning Addressable Combustion Sensing AWACSTM is a set of software algorithms that provide the AFP-300/400 with industry-leading smoke detection capability. The development of these sophisticated algorithms are made possible by the close cooperation between Notifier and System Sensor, the world leaders in fire detection and alarm technology. These complex algorithms require many calculations on each reading of each detector, and are made possible by the very high speed microcomputer used by the AFP-300!400 (16-bit RISC Reduced Instruction Set Computer). 0 Drift Compensation and Smoothing. These S algorithms (U.S. patent pending) identify and compen- sate for long-term changes in the analog readings from each smoke sensor. Long-term changes are usually Analog caused by dust accumulation inside the smoke chamber. Reading Drift compensation allows the detector to retain its origi- nal ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance re- quirements by allowing the system to automatically per- form the periodic sensitivity measurements required by NFPA Standard 72. Smoothing filters are also provided by software to remove transient noise signals, usually caused by electrical interference. Different smoothing algorithms are used, depending on the sensitivity selec- tion of each detector. O Maintenance Warnings. When the drift compensation performed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value, usually indicative of a hardware problem in the detector; (2) Main- tenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. The Maintenance Alert level allows maintenance before the performance of the device is compromised. 6 Sensitivity Adjust. Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predetermined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate special control functions that are a subset of the alarm control program. O Self-Optimizing Pre-Alarm. Each detector may be set for "Self-Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog read- ings over a long period of time, and setting the pre-alarm level just above these normal peaks. This allows extremely sensitive pre- alarm capability with reasonable protection against non-fire sig- nals. Alarm Level without compensation with compensa and smoothing Time (days) jo Awacsl.wmf DIRTY Maintenance Urgent P - - - - - Alert Acceptable Range Low Chamberj____________ Reading Low Value Awacs2 wmt — Prealarm Threshold Normal Threshold Time (days) Awacs4.wmnf O Cooperating Multi-Detector Sensing. A unique feature of AWACSTM is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre-alarm decisions. Using logic algorithms, each sensor can include up to two other Alarm sensors in its decision. Without statistical sacrifice in the ability -- -- - to resist false alarms, it allows a sensor to increase its sensitivity Combid - - to actual smoke bya factor of almost 2tol. Multi-detector sensing - - 3 Sensors - - - - - - - -- also allows the combination of ionization with photoelectric tech- . w - - - - - - - - - - - nology in reaching an alarm decision. 0 - - Time (minutes) 02620w0.wm! DN-5262 • 07/06/01 - Page 5 of 10 U M 41 -. System Par or PLO 'CALL POOH 40 CHAr CUT0M 44L'-E C 04 I- T- tO O 40 44, 0 0€ 0 ,J &O 4 hO! (000.4 (LA A44 COCA LOCAL 0 52 20e41.0r( C AUTOPROGRAM FIELD PROGRAMMING OPTIONS Autoprogram is a timesaving feature of the 300/400. It is PUTIJPROGRPM PLEASE WAIT a special software routine that allows the 300/400 to "learn" what devices are physically connected and automatically load them in the program with default values for all param- eters. Requiring less than 30 seconds to run, this routine allows the user to have almost immediate fire protection inEl l TS, 15 MUDS L2:93' DETS, 35 NODS a new installation, even if only a portion of the detectors NEL OUTPUTS: 24 BELLS: 04 are installed. The routine will find all intelligent detectors ____________________________________________ and modules, and present them to the installer for edit of the default option selections, if desired. If a device is found that already exists in memory, autoprogram skips over that device (only new devices or missing devices are presented to the installer). Often the installer will perform autoprogram as a first step in a new installation, then upload the program into a PC to add all custom labels and other information, then download from the PC to the 300/400. KEYPAD PROGRAM EDIT The 300/400 has the exclusive feature of full program creation and edit capability from the front panel keypad, while continuing to provide fire protection. The archi- tecture of the 300/400 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be en- tered with independent per-point segments, while the 300/ 400 simultaneously monitors other (already installed) points for alarm conditions. ENTER PROC OR STIT PASSWORD, THEN ENTER (ESCAPE TO ABORT) *44:*+ 0=CLR 1=flUTO "'=POINT 3=PllSSIiJD 4NESScloE 5ONES 6=SPL FUNCT 7=SYSTEM 8CHECK PRG In addition to avoiding system shutdown, program edit from the panel keypad has the advantage of not requiring an on-site PC. This can save significant installation time for minor program changes. The 300/400 site-specific program is password pro- tected, and all information is stored in nonvolatile memory. Menu "trees" are provided to lead the trained installer through the program steps without the necessity to refer to the programming manual. I VeriFireTM Software PC software is available for off-line programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific soft- ware. VeriFireTM is a Windows®-based program provid- ing technologically advanced capabilities to aid the in- staller. The installer may create the entire program for the 300/400 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. The program includes error checks for common program- ming mistakes, such as an input point that does not acti- vate any outputs, or an output point that is not linked to any inputs. It also includes a simulation routine that will list all of the output points that are activated by a particu- lar input point (alternatively, it will list all the input points that are linked to a particular output). Although this does not eliminate on-site testing, it greatly increases confi- dence in the final installation. For example, a 200-input and 100-output point system, without using the software, could require 20,000 test observations to verify all pos- sible I/O links. The software includes a compare routine, pictured at right, that can also greatly help the installer. When a new program is created, it may be compared with a previous version and differences are highlighted. If the program is modified from the panel keypad, it may be uploaded into the PC, and compared with the previous version stored on disk. The identification of program differences greatly helps the installer in testing the installation. NFPA 72 requires that reacceptance test of a fire alarm system be performed on 100% of all points that are 'known" to be modified. The software allows the installer to determine the exact points that are changed. 5262-2P1 Page 6 of 10 - DN-5262 • 07/06/01 BASIC EQUIPMENT PACKAGES There are two packages available to configure an AFP- 300 or 400 system. The standard model, BE-300 or BE-400, is designed to mount in a NOTIFIER full-sized cabinet in the CAB-3 Series. The BE-300AA or BE- 400AA is a miniature package designed for a smaller cabinet, the CAB-400AA. Order one of the following BE packages: BE-400: Base Equipment includes the CPU (2 loops) module (CPU-400), an 80-character display, program- ming keypad, MPS-400 main power supply, installation instructions, chassis and required hardware. Order CAB-3 Series cabinet separately. BE-400AA: Base Equipment for use with CAB-400AA mini cabinet. It is similar to BE-400 but for use in smaller cabinet. Includes MPS-400RB and transform- ers. Supports one output option module. Order CAB- 400AA cabinet separately. BE-300: Base Equipment includes the CPU (lloop) module (CPU-300), an 80-character display, program- ming keypad, MPS-400 main power supply, installation instructions, chassis and required hardware. Order CAB-3 Series cabinet separately. BE-300AA: Base Equipment for use with CAB-400AA mini cabinet. It is similar to BE-300 but for use in smaller cabinet, Includes MPS-400RB and transform- ers. Supports one output option module. Order CAB- 400AA cabinet separately. CAB-3 Series: The AFP-300/400 utilizes CAB-3 Series cabinets (see data sheet DN-3549). SYSTEM MODULES The AFP-300/400 includes the ability to communicate with up to 8 conventional modules each with up to 8 circuits. Any mix of notification, relay, speaker, or tele- phone may be used. Choose any combination of up to eight output modules: 1CM/ICE, CRM/CRE, DCM-4 or VCMNCE. ICM-4: Notification Appliance Circuit Module, provides four Style Y or Style Z alarm Notification Appliance Circuits. Maximum signaling current is 3.0 amps per circuit or 6.0 amps per * module, subject to power supply limita- tions (includes auxiliary power harness, , LIEL1 ELRs and slide-in labels). Includes ON/ LJELI OFF controls and ON/OFF LEDs. ICE-4: Notification Appliance Circuit ° Expander, expands ICM-4 to provide a total of eight (8) Style Y or Style Z alarm 14111 1414 Notification Appliance Circuits. Circuit ratings are same as lCM-4. (Maximum of = one per ICM-4.) May also be used to add four Notification Appliance Circuits to VCM-4. CRM-4: Control Relay Module, four (4) Form-C relay contacts, rated at 5.0 A, 120 VAC or 28 VDC (resistive) per circuit. Includes manual ON/OFF controls and LEDs. ID 19~ fl CRE-4: Control Relay Expander, expands CRM-4 to provide a total of eight (8) Form-C relay contacts. (Maximum of one per CRM- 4.) May also be connected to add four relays to lCM-4, TCM-2, TCM-4, or VCM-4. VCM-4: Voice Control Module provides four Style Y or Style Z speaker circuits, eight manual select switches and indicators, slide-in labels, and plug-in terminal blocks. Move jumper to convert to telephone circuits with remote ring signal and local call-in flash. May be expanded to 8 circuits with VCE- 4, ICE-4, or CRE-4. VCE-4: Voice Control Expander adds four I'll circuits to VCM-4. (Note: VCM-4 / VCE-4 combination must be 8 speaker or 8 phone circuits.) ED DCM-4: Dual Channel Module provides four Style Y or Style Z speaker circuits plus four channel A/B select relays. Not expandable. OTHER OPTION MODULES - ARM-4: Auxiliary Relay Module, four (4) Form-C relays controlled by a relay module (CRM-4 or CRE-4). N. 0. contacts rated 20 amps, N.C. contacts rated 10 • amps at 125 VAC and 30 VDC. (Max!- mum of one for each CRM-4 or CRE-4.) VCC-1: Voice Control Center. Provides a variety of user selectable tones on a single channel. Up to two different tones or messages may be selected on a single channel. Also provides optional digital voice message capability and on-site programmable voice messages. Includes Audio Message Generator (AMG- 1) microphone, cables, dress panels, and instructions. VCC-2: Voice Control Center. Single or dual channel Audio Tone Generator (ATG-2). Provides a slow whoop, Hi/Lo or steady tone on the primary channel and for dual channel applications, provides a chime or 20 pulse-per-minute tone on the secondary channel. Includes cables, microphone, dress panel, and instructions. VTCC-1: Voice/Telephone Control Center. Provides all that the VCC- 1 provides plus two-way Fire Fighter's Telephone (FFT-7) capability. VTCC-2: Voice/Telephone Control Center. Provides all that the VCC-2 provides plus two-way Fire Fighter's Telephone (FFT-7) capability. TCC-1: Telephone Control Center. Provides a stand- alone two-way Fire Fighter's telephone (FFT-7S). Includes cables, dress panel and instructions. AMG-E: Audio Message Generator (without microphone). Order in addition to VCC- 1 or VTCC- 1 if two-channel system is required. DN-5262.07/06/01 -. Page 701 10 ee IIIIT 0 S FFT-7/FFT-7S: Fire Fighter's Telephone control with master handset. AA-30: Audio Amplifier - 30 watts. Switch-mode power. Includes amplifier and audio input supervision, backup input, and automatic switchover, power supply, cables. AA-120IAA-100: Audio Amplifier provides up to 120 watts of 25 VRMS audio power for the AFP -400. The amplifier contains an integral chassis for mounting to a CAB-B3, -C3, or -03 backbox (consumes one row). Switch- mode power. Includes audio input and amplified output supervision, backup input, and automatic switchover to backup tone. Order the AA-100 for 70.7 VRMS systems and 100 watts of power. VROM-(n): Factoty-programmed message for installation in AMG-1. Provides up to 24 seconds of evacuation message on nonvolatile memory chip. Choose one of many standard messages available. Up to two of these messages may be installed vo in one AMG. Includes VROM, 3576vr0m.wmf instructions for installation and operation, and written text of message. VRAM-1: Field-programmed memory to be installed in AMG-1. Provides up to 24 seconds of field-programmable - evacuation message on nonvola- tile memory chip. Message is programmed from microphone or - cassette tape. Up to two of these 1J O74Oram.wmI nonvolatile memory chips may be installed in one AMG. Includes VRAM and instructions for installation and operation. Page 80110 - DN-5262 • 07/06/01 UZC-256: Programmable Universal Zone Coder provides positive non-interfering successive zone coding. Microprocessor-controlled, field-programmable from IBM-compatible PCs (requires programming kit). (See UZC-256 data sheet.) LCD-80/LCD-80TM: 80-character, backlit LCD display. Mounts up to 6,000 ft. from panel. Up to 32 per AFP- 400. (See LCD-80, LCD-80TM data sheets.) ACS: Annunciator Control Modules ACM- I6AT, AEM- 16AT, ACM-32A, and AEM-32A. (See ACS data sheet.) AFM: Annunciator Fixed Modules AFM-16A, AFM-16AT, and AFM-32A. (See AFM data sheet.) LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM- R32. (See LDM data sheet.) ACM-BR: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. from panel on four wires. (See ACM-8R data sheet.) RPT-485: Repeats EIA -485 over twisted pair or converts to fiber-optic medium. (See RPT data sheet.) XP: The XP Series Transponder provides conventional monitor and control points. (See XP data sheet.) CHS-4L: Low-profile four- position Chassis. Mounts two AA-30 amplifiers or one AMG- E and one AA-30. = = = 5262Ch4L.wml CHS-4M: Expansion Chassis. Mounts up to four mod- ules. Includes CHS-4, MP- 1 (Module Dress Panel), and Expander Ribbon Cable. DP-1: Blank Dress panel. - Provides dead-front panel for unused tiers or to cover AA- 30 AA- 120 or AMG-E. 5262dp1 wn CAB-3 Series: The CAB-3 Series cabinets are fabricated from 16-gauge steel with unique full-front LEXANc, reverse silk-screened for durability. The cabinet assembly consists of two basic parts: a backbox (SBB-_3), and a locking door (DR-_3) that may hinge right or 5871ceb3 wml left. Cabinets are arranged in four (4) sizes, A through 0 (B [two-tier] is pictured at right). A trim ring option is available for semi-flush mounting. (See CAB-3 Series data sheet.) LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. CAB-400AA: Provides small cabinet for CPU-400 and MPS-400RB. Use with BE-400AA only. Space for one (only) output circuit module plus expander. XPIQ: Intelligent transponder designed for multi-channel applications. (See XPIQ data sheet DN-6823.) APS-6R: Auxiliary Power Supply (expander). Provides up to 6.0 amperes of regulated power for compatible Notification appliance circuits. Includes battery input and transfer relay, and overcurrent protection. Mounts on one of four positions on a CHS-4L or CHS-4 chassis. S FCPS-24: The FCPS-24 is a remote 6- 5952c0v.wmf amp (4-amp continuous) repeaterl power supply. CHS-4: Chassis for mounting up to four APS-6R. L r MPS-400: Power Supply module. The MPS-400 includes 4 Notification Appliance Circuits (NA C) that can connect four Class A (Style Z) or Class B (Style Y) circuits. The NAC also can be used for Releasing applications. Includes four built-in system relays (alarm, trouble, security, and supervisory). For BE-400 replacement only. The MPS-400 is included in the BE kits. MPS400RB: MPS-400 PC board only. Less trans- formers and mounting chassis. AGENCY LISTINGS AND APPROVALS See the first page of this catalog sheet for listing agencies and file numbers. These listings and approvals apply to the basic AFP-300 or AFP-400 control panel. In some cases, certain modules may not be listed by certain ap- proval agencies, or listing may be in process. Consult factory for latest listing status. The AFP-300/400 is UL Listed, per Standards 864 (Fire) and 1076 (Burglary). It meets NFPA 72 Local, Auxiliary, Remote Station, Proprietary, and Emergency Voice/Alarm Fire Sys- tem Requirements. SPECIFICATIONS Primary input power, 120 VAC, 50/60 Hz, 3.0 Amps. Total output 24 V power - 6.0 A.* Standard Bell circuits (4) per MPS-400 - 2.5 A each. Four-wire detector power - 1.25 A. Two non-reset regulated power outputs - 1.25 A each. Battery charger range: 12 AH - 60 AH. (Use separate BB-55 cabinet for 55/60 AH batteries.) Charge high rate: 29.1 V. Float Rate: 27.6 V. Note: The MPS-400 has a total of 6.0 Amps of available power. This is shared by all internal modules and each MPS400 circuit. SYSTEM CAPACITY: APP-400 Intelligent Signaling Line Circuits ................................2 Intelligent Detectors .................................................198 Addressable monitor/control modules.....................198 Programmable internal hardware and output circuits (four standard) ............................68 Programmable software zones ..................................99 Special Programming zones .....................................14 Programmable remote relay/annunciator points.......99 LCD-80 annunciators per system (observe power) .. 32 ACS annunciators per system ... 1 0 Address x 64 points SYSTEM CAPACITY: AFP-300 Intelligent Signaling Line Circuits ................................1 Intelligent Detectors ...................................................99 Addressable monitor/control modules.......................99 Programmable internal hardware and output circuits (four standard) ............................68 Programmable software zones..................................99 Special Programming zones .....................................14 Programmable remote relay/annunciator points.......99 LCD-80 annunciators per system (observe power) .. 32 ACS annunciators per system... 10 Address x 64 points CONTROLS AND INDICATORS Program Keypad: QWERTY type (keyboard layout). 8 LED indicators: AC Power; Fire Alarm; Pre-Alarm; Se- curity Alarm; Supervisory Signal; System Trouble, Disabled points, Alarm Silenced. Membrane Switch Controls: Acknowledge/Step; Silence; Evacuate; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED backlight. COMPATIBLE DEVICES, EIA-232 Port PRN-5 80-column printer. V54095/S2 Printer, 40 column, 24 V. Mounted in exter- nal backbox (order from Keltron, Inc.). CRT-2 Video display terminal. NAM-232W Wire peer-to-peer NOTI• FIRE- NET net- work interface module (see separate data sheet). NAM-232F Fiber peer-to-peer NOTI • FIRE • NET" net- work interface module (see separate data sheet). *VGAS Video Graphic Annunciator System (see separate data sheet). Note: * Not UL 864 listed (ancillary device only). COMPATIBLE INTELLIGENT DEVICES FSI-751 Ion detector. FSP-751 Photo detector. FSP-7511 Photo detector with fixed thermal element. FST-751 Thermal detector, fixed. FST-751 R Thermal detector, fixed and rate-of-rise. LPX-751 VIEW® detector. HPX-751 HARSH TM photo detector (requires special base). IPX-751 Advanced multi-criteria detector (ion/photo/ thermal). FSD-751P Duct detector, with housing. FSD-751 RP Duct detector, with housing and relay. INTELLIGENT DETECTOR BASES B71OLPBP Standard flanged base, package of ten. B510BP Standard flangeless base, package of ten. B71OHD Base for HPX-751 (HARSH TM) only. B224RB Relay base. B224B1 Isolator base. B501BH Sounder base. B501BHT Sounder base with temporal sounder. COMPATIBLE ADDRESSABLE DEVICES NBG-12LX Addressable pull station, visible LED. FMM-1 Monitor module. FMM-101 Monitor module, miniature. FDM-1 Monitor module, dual, two independent Class B circuits. FZM-1 Monitor module, two-wire smoke detectors. FCM-1 Control module. FRM-1 Relay module. DN-5262 • 07/06/01 - Page 90110 XP5-M Transponder, monitor, five addressable Class S B circuits. XP5-C Transponder, control/relay, five addressable Class B circuits. lSO-X Isolator module. NOTE: All addressable devices listed above may only be used with the AFP-300/400 software revision 3.61 or higher. COMPATIBLE DEVICES, RS-485 Port (see separate data sheets) ACS Series Remote Serial Annunciator/Control sys- tems. LCD-SO Remote LCD display. LDM Series Remote custom graphic driver modules. ACM-8113 Remote relay module. 8 Form-C relays. NIB-96 Network Interface Board. RPT-485 Series Repeater, isolator and/or fiber optic mo- dem. UDACT Universal Digital Alarm Communicator Transmitter. UZC-256 Zone Coder. Up to 256 programmable codes. OTHER ACCESSORIES 4XTM Plug-in Transmitter Module. Provides municipal box and remote station con- nection. PS Series Batteries; the AFP-300/400 battery range S ROM-AFP400 is 12 A to 60 AH. Refer toDN-1109. Panel software upgrade kit. Includes latest factory software (consult factory). BB-55(F) Battery Box (required for 55/60 AH). Order F' suffix for red cabinet. VeriFire-CD Programming kit for PC. Includes CD, cable, and instructions. VeriFire-CDUG Same as VeriFire-CD above except it does not include the cable. Other options as listed in previous sections. Page 10sf 10— DN-5262•07/06/01 S LISTING No CATEGORY LISTEE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-0028:181 Control Units (Non High-Rise) Notifier, One Fire-Lite Place, Northford CT 06472-1001 Contact: Larry Flood (203) 484-1200 Page 1 of 2 DESIGN: Models AFP-300 and AFP-400 fire alarm control units. Automatic, manual, coded, non- coded, local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU). Also suitable for waterflow and sprinkler supervisory service. Refer to listees data sheet for additional detailed product description and operational considerations. System components: CPU-300/400 MPS-400 CAB-A3/-B3/-C3/-D3/-400AA 4XTM BB-1 7/-55 MMX-1/-1 01 lSO-X N-ELR/A21 43-00 CMX-1 XPP-1 /XPM-8/XPR-8IXPC-8 XPDP CRT-2 ARM-4 AVPS-24 CRE-4 CRM-4 FCPS-24 FKS-2400 ICE-4/ICM-4 NIB-96 NR45-24 RPT-48 5 F/-WI-WE UZC-256 MP-1 /DP-1 /-3/-400AA BM-1 TR-500 ICM-4 NAM-232 MPS-24A/-24B ABS-4D ADP-4 INA CPU Board Power Supply Board Enclosure Transmitter Module Battery box Monitor Module Isolator Module EOL Resistor Control Module XP Transponder Transponder Dress Panel Terminal with Keyboard Auxiliary Relay Module Audio/Visual Power Supply Control Relay Expander Control Relay Module Field Charger Power Supply Modem Indicating Control Expander Network Interface Board Notifier Remote Battery Charger EIA-485 Repeater Universal Zone Coder Dress Panel Blank Module Trim Ring Indicating Control Module Network Adapter Module *Main Power Supply *Annunciator Backbox *Dress Panel *Remote Annunciator Refer to CSFM Listing No. 7170-0028:182 for additional optional accessories. 0 Listing No, 7165-0028:181 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Units can also generate the temporal code pattern as required per NFPA 72, 1996 Edition. NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. *Rev. 02-01 -01 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test (r J results and/or other data but does not make an independent verification of any claims This listing is not an endorsement or recommendation of the item listed This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager B -- ------ (41 .275) 11-9/32 5/16 dia. 5/16" dia. (286.545) (7.938 mm) (7.938 mm) 0*' N 4-19-1/2' (495.300) (mm) 2-1/4' (57.150) (130.969) (52.388) 5-5/32" 2-1/16" 85/80 (219.075) 20" - (508.000) — 2-9/16" (65.088) 24 (609.600) 24-1/8 (612.775 mm) : 16 (406.400) -p) CAB-A3 3549e3.wrnt S (0 NOTIFIER 0 November DN-3549• G-181 CAB-A3, 133, C3 & D3 Cabinets, and CAB-M Marine Enclosures Section: Peripheral Devices S GENERAL All cabinets for NOTIFIER fire alarm control panels are fabricated from 16-gauge steel. The cabinet assembly con- sists of two basic parts: a backbox and a locking door. Cabinets are available in either gray or red, with or without LEXAN® windows. This flexibility produces a tasteful com- bination to accent the decor of the finest lobby setting. The key-locked door is provided with a pin-type hinge, two keys and the necessary hardware to mount the door to the backbox. The backbox has been engineered to provide ease-of-entry for the installer. Knockouts are positioned at numerous points to aid the installer in bringing a conduit into the enclosure with a minimum of hardship. Right- or left-hand hinges, selectable in the field. Door opens 1800. Cabinets are arranged in four (4) sizes, A through D. A trim ring option is available for semi-flush mounting. Chassis bridge available for assembling multiple CHS-4 chas- sis external to the backbox. CAB-M MARINE CABINETS NOTIFIER marine cabinets are designed to house the AFP- 200, AFP1010, or AM2020 in marine shipboard environ- ments where dirt, dust, oil, water, or other contaminants are present. Smooth, blended surfaces and an attractive finish compliment the NOTIFIER fire alarm control panel. LISTINGS FOR THE CAB-3 SERIES: California * State Fire Marshal 7165-0028:141 7165-0028:144 LISTED CS68 7165-0028:181 S635 7170-0028:153 7170-0028:154 lIJI EA 7170-0028:182 289-91-E Vol. IV 290-91-E Vol. IV *(except solid-door models) 447-99-E CAB-3 TRIM RINGS Trim rings are available for semi-flush mounting the cabinet. An adhesive tape is used to attach this trim to the wall beside the cabinet. Gray trim rings are 15/16' (23.8125 mm) thick. Red trim rings are 1.25" (31.75 mm) painted metal and screwed in place. CAB-3 PRODUCT LINE CAB-3 Series cabinets are available in four sizes: A (one tier), B (two tiers), C (three tiers), and D (four tiers). Dia- grams with dimensions are included here; ordering informa- tion is on page 3. All cabinets and doors are available in either red or gray, with or without LEXAN® windows. LEXAN® is registered trademark of GE Plastics, a subsidiary of General Electric Company. See page 2 for other CAB-3 Series diagrams and additional information on CAB-114 marine enclosures. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. I ISO 9001 I For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 a NOTI Fl FE 12 Clintonville Road, Northford, Connecticut 06472 BIERINC & MANUMTUBINC Made in the U.S.A. DN-3549" 11/28/01 — Page 1 of 3 37-1/4' (946.150) .- 24.1/8' (612.775 mm) CAB.M PRODUCT LINE INFORMATION Model Gauge: Door Enclosure Size (mm) Panel Mounting Plate Number & Backbox (mci. with CAB-AM, -BM) CAB-AM 14 door, 24" I-1x30'Wx8" D 28.2"x22.2' 6backbox (610 H x 762 W x 203 D) (716x564mm) CAB-BM 14 door, 36" H x 30' W x 8" D 34.2 x 28.2' 6backbox (914 H x 762 W x 203 D) (869x716mm) Panel mounting plates; order separately as required replacemenfiretro fit parts. PL-AM For use with SBB-A3 or AFP-200. PL-BM For use with SBB-83. 1-5/8" (130.969) (52.388) (41.275) 5-5/32' 2-1/16' 6 1925/32" (502.444) .-.. (219.075) . (219075) (723900) Ho-- L. 2-1/4' (57.150) (mm) 2-9/06" . (65.088) H 15/8' (130.969) (5 (41.275) 2 (279.075) 1 8-5/8' 283/32' (219.075) (713.561) I 8-5/8' 37-1/8' (219.075) (942.975) --0....... 2-1/4 (57.150) (mm) 24" (609.600) '1 (130.969) (52.388) :)10l6, 16" (406.400) -. (41.275) 5-5/32 2-1/16" Vi snown wnnour - transparent window FOR THE CAB-M SERIES: U.S. 161.002/23/1 Coast (AFP-200 - CAB-AM) 161.002/27/1 Guard (AM2O2OIAFPIOIO- CAB-AM, CAB-BM) 11 93/00140 JUf (AM2020IAFP10I0- CAB-AM, CAB-BM) 94/00004 (AFP200 - CAB-AM) ABOUT CAB-M 16-gauge steel backbox with integral trough offset. 14-gauge steel door, all welds ground smooth. 90 opening door with zero clearance; 1800 opening with full clearance. - Compression stops maintain optimum gasket performance. - Removable doors with zinc diecast hinges. Backbox and door ground studs pro- vide positive ground. Slotted quarter-turn oil-tight latch and key lock. Includes LEXAN® window allowing full view of control panel display with door closed. Includes panel mounting plate pre- drilled for NOTIFIER control panel mounting. Backbox and door to be painted gray polyester powder inside and out over phosphatized surfaces. NEMA Type 4; UL 508 Type 4; E.I.A. RS-310-C; CSA Type 4; TUV-IEC 529, 11355. 24" (609.600) 24-1/6" (612.775 mm) -H 16' (406.400) 3 5/16 die. 5/76" die. (7.938 mm) (7.038 mm) - 19-1/2'(495.300) ..-. 2-1/4' (57.150) e- 24' (609.600) 24-1/6' (612.775 mm) -. 1.6)f 16' (406.400) 5/16' dim. 5/16"di8. (7.938 mm) (7638 mm) 19-1/2' (495.300) 2-1/4' (57.750) CAB-D3 45-7/8') Page 2 of 3 - DN-3549 - 11/28iU1 8-5 37-1/32" (940.594) 4. 5/16" dia. 5/15/ 6a. (7.928mm) (7.938 mm) N ..- 19-1/2 (495.300) - 2-1/4 (57.150) 2-1/4 (57.150) (mm) B.D3B th solid or. lid door ition ailable on sizes in ay or red. CAB-3 SERIES ORDERING INFORMATION ONE TIER, GRAY: CAB-A3 Cabinet and door assembly, with LEXAN® window, one tier, gray. CAB-A3B Cabinet and doorassembly, with solid door, one tier, gray. TR-A3N Accessory semi-flush-mount trim ring, one tier, gray. DR-A3 Replacement door only, with LEXAN® window, one tier, gray. DR-A3B Replacement door only, solid door style, one tier, gray. SSB-A3 Replacement backbox only, one tier, gray. ONE TIER, RED: CAB-A3R Cabinet and door assembly, with LEXAN® window, one tier, red. CAB-A3BR Cabinet and door assembly, with solid door, one tier, red. TR-A3R Accessory semi-flush-mount trim ring, one tier, red. DR-A3R Replacement door only, with LEXAN® window, one tier, red. DR-A3BR Replacement door only, solid door style, one tier, red. SSB-A3R Replacement backbox only, one tier, red. TWO TIERS, RED: CAB-1133R Cabinet and door assembly, with LEXAN® window, two tiers, red. CAB-133BR Cabinet and door assembly, with solid door, two tiers, red. TR-B3R Accessory semi-fl ush-mou nt trim ring, two tiers, red. DR-1133R Replacement door only, with LEXAN®window, two tiers, red. DR-B3BR Replacement door only, solid door style, two tiers, red. SSB-B3R Replacement backbox only, two tiers, red. THREE TIERS, GRAY: CAB-C3 Cabinet and door assembly, with LEXAN® window, three tiers, gray. CAB-C3113 Cabinet and door assembly, with solid door, three tiers, gray. TR-C3N Accessory semi-fl ush-mounttrim ring, threetiers, gray- DR-C3 Replacement door only, with LEXAN®window, three tiers, gray. DR-C313 Replacement door only, solid door style, three tiers, gray. SSB-C3 Replacement backbox only, three tiers, gray. THREE TIERS, RED: CAB-C3R Cabinet and door assembly, with LEXAN® window, three tiers, red. CAB-C3BR Cabinet and door assembly, with solid door, three tiers, red. TR-C3R Accessory semi-flush-mounttrim ring, threetiers, red. DR-C3R Replacement door only, with LEXAN®window, three tiers, red. DR-C3BR Replacement door only, solid door style, three tiers, red. SSB-C3R Replacement backbox only, three tiers, red. FOUR TIERS, GRAY: CAB-D3 Cabinet and door assembly, with LEXAN® window, fourtiers, gray. CAB-D313 Cabinet and door assembly, with solid door, four tiers, gray. TR-D3N Accessory semi-fl ush-mou nt trim ring, fourtiers, gray. DR-D3 Replacement door only, with LEXAN® window, four tiers, gray. DR-D3B Replacement door only, solid door style, four tiers, gray. SSB-D3 Replacement backbox only, fourtiers, gray. FOUR TIERS, RED: CAB-D3R Cabinet and door assembly, with LEXAN® window, four tiers, red. CAB-D3BR Cabinet and door assembly, with solid door, four tiers, red. TR-D3R Accessory semi-fl ush-mou nt trim ring, fourtiers, red. DR-D3R Replacement door only, with LEXAN® window, four tiers, red. DR-D3BR Replacement door only, solid door style, four tiers, red. SSB-D3R Replacement backbox only, fourtiers, red. ACCESSORIES: WC-2 Wire channel. Provides a pair of wire trays to neatly route wiring between CHS chassis. CB-1 Chassis bridge. Provides a bridge between CHS Series chassis. DP-1 Blank dress panel, covers one CAB-3 tier, gray. TWO TIERS, GRAY: CAB-1133 . Cabinet and door assembly, with LEXAN® window, two tiers, gray. CAB-133B Cabinet and door assembly, with solid door, two tiers, gray. TR-B3N Accessory semi-flush-mou nt trim ring,twotiers, gray. DR-1133 Replacement door only, with LEXAN®window, two tiers, gray. DR-113313 Replacement door only, solid door style, two tiers, gray. SSB-B3 Replacement backbox only, two tiers, gray. DN-3549• 11/28/01 - Page 3 of 3 I-I •II• JS ©Q Hii© MS© PRIMARY ACTiVE PHi PH2 1! OPOWPR OCOMM. FAIL © OEJnia5 0105$ OFF TT lE 1LEJL !I JLiLE11I Ii 0 fl o U TF- EIIILIIJ JO S October 24, 1997 D-160 I UDACT I 4NOTIFIER" Universal Digital Alarm A Pittway Company Communicator Transmitter I I Section: Annunciator Control Systems I AFP1010, AFP-400, AFP-300, AFP-200, System 5000 and The Universal Digital Alarm Communicator Transmitter also designed for use on the Intelligent Network Annuncia- GENERAL (UDACT) is designed for use on the NOTIFIER AM2020, System 500 Fire Alarm control panels. In addition, it is S635 CS100 099California INDUSTRY Vol. VII I r State Fire CANADA Marshal 2132 6030 A 7300-0028:174 tor (INA), software release 2.8 or higher. When used in IWGUSA- conjunction with the INA, the UDACT can report the status 20723-AL-E of all control panels on NOTI• FIRE • NET TM. The UDACT MEA transmits system status to UL listed Central Station Re- ceivers via the public switched telephone network. 328-94-E The UDACT is compact in size and may be mounted exter- nally in a separate cabinet. EIA-485 annunciator commu- <FM> nications bus and regulated 24 volt connections are re- quired. 1ZOA4.AY The UDACT is capable of transmitting the status of soft- (with Ademco 685 only) ware zones (Alarm and Trouble), System Trouble, Panel Off-Normal, Supervisory, Bell Trouble, Low Battery, and cDCD AC Fail. When used with the AFP-200, the UDACT trans- ABS-8R mits up to 89 zones; with the System 500, all 16 zones; for and with the System 5000, all 120 zones. When used with o remote the AFP-400, the UDACT is capable of reporting up to 567 o mounting points; with the AFP-300, up to 375 points. Reporting may A (9.94" H be in the form of software zones (99 plus 16 special), panel . 4.63" W circuits 1-4, panel output modules 1-64, and 192 points 2.5"D) per SLC loop (the first 96 detector and 96 module ad- dresses). When the UDACT is used with the AM2020 orAFP1010, it is capable of reporting up to 2,040 points. Reporting may be in the form of software zones (up to 240) or 60 zones plus up to 1980 intelligent points. The first 568 points trans- mitted may be programmed for a variety of types, including fire, waterflow, supervisory, etc. Remaining points trans- mitted are for fire alarm only. INOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Ademco Contact ID for- mat. See chart on page 2 for compatible receivers. FEATURES Dual phone lines. Dual telephone line voltage detect. Surface Mount Technology. Compact in size: 6.75" x 4.25". Built-in programmer. Built-in 4-character red 7-segment LED display. Manual Test Report function. Manual Transmission Clear function. Mounts in a separate enclosure (ABS-8R or UBS-1). Communicates vital system status including: - Independent zone fire alarm. - Independent zone non-fire alarm. A - Independent zone trouble. UDACT - Independent zone supervisory. - AC (mains) Power Loss (programmable). - Low Battery and Earth Fault. - System Off-Normal. - 12 or 24 hour test signal. - Abnormal Test Signal per new UL requirements. - ElA-485 Communication Bus Failure. Annunciation of UDACT Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. Troubleshoot Mode converts keypad to DTMF touchpad. Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kissoff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. Open Collector relay driverfor Total Communications Fail- ure or UDACT trouble. Real-time clock. Extensive transient protection. Simple EIA-485 interface to host panel. AGENCY LISTINGS AND APPROVALS See above for listing agencies and tile numbers. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. This document is not intended to be used for installation purposes. We try to keep our I product information up-to-date and accurate. We cannot cover all specific applications or ISO-9001 anticipate all requirements. All specifications are subject to change without notice. For Engineering and Manufacturing more information, contact NOTIFIER. Phone: (203) 484.7161 FAX: (203) 484-7118 Quality System Certified to N OTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 International Standard ISO-9001 Made in the U.S.A. DN-4867 - Pagel 016 S [I S INSTALLATION When used with the AFP-200, the UDACT mounts in the ABS-8R or UBS-1 backbox. When used with the System 500, the UDACT can mount in the CAB-500 far back (nor- mally NIB-96) position. When used with the System 5000, the UDACT can mount in any far back (front module with expander allowed) posi- tion of the CHS-4 chassis. When used with the AM2020, AFP1010, AFP-400, orAFP- 300, the UDACT mounts in a CHS-4 or CHS-4L module position. In all cases, the UDACT can mount remotely (up to 6,000 ft.) in an ABS-8R or UBS-1 backbox. NOTE: Due to space considerations, the far back of the CAB- 500 position is NOT recommended. COMMUNICATION FORMATS 3+1 Standard • 4+1 Standard • 4+2 Standard 4+1 and 4+2 Ademco Express • Ademco Contact ID NOTE: Ademco Contact ID must be used for independent zone reporting. REQUIRED SOFTWARE AFP-200 English EPROM* = 73609 (or higher) AFP-200 Spanish EPROM* = 73618 (or higher) AFP-200 French EPROM* = 73617 (or higher) AFP-400 EPROM* = #AFP4R20 (or higher) System 500 EPROM* = 73611 (or higher) System 5000 EPROM* = 73610 (or higher) AM2020/AFP1010* = Release 6.6 (or higher) AFP-300/AFP-400 = ALL Presently, the UDACT is not capable of AC. Fail delay (per 1993 NFPA standards) when used with the AA Series Amplifier, A VPS Power Supply, or the XP Transponder. TYPE MODE FEATURE (Ademco Contact ID format only) Use Type Mode to identify reports to Central Station as: Fire Alarm • Burglary Supervisory • 24 hour Non-Burglary Pull Station • High Temperature Heat Detector • Low Temperature Waterflow • Low Water Pressure Duct Detector • Low Water Level Flame Sensor • Pump Failure Smoke Zone UDACT shown in UBS-1 Page 2 of 6 - DN-4867 ORDERING INFORMATION UDACT Universal Digital Alarm Communicator Trans- mitter. Includes operating instructions, pro- gramming instructions and mounting hard- ware. MCBL-7 DACT phone cord, seven feet long (two re- quired). ABS-BR Metal enclosure for externally mounting UDACT up to 6,000 ft. from host FACP. UBS-1 Metal enclosure. Includes viewing window and optional relay mounting capability. MR-101/C SPDT Form-C relay. Contacts rated for 10A @ 115 VAC. Connects to open collector re- lay driver. MR-20111C DPDT Two Form-C relays. Contacts rated for 10A @ 115 VAC. Connects to open col- lector relay driver. FBD-1 Ferrite bead kit. Use for remote mounting only. ELECTRICAL SPECIFICATIONS Standby current: 40 mA. Current while communicating: 75 mA. Maximum current while communicating and with open collector output activated: 100 mA. Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. Osborne Radionics Silent UI Hoffman 60001 Sescoa Sur-Gard Format # Ademco Knight CS-4000 FBI Models 6500 300CR MLR-2 (Addresses 16 & 42) 685(1) 9000 (3) CP220FB 1&2 (5) 171 191 O 4+1 Ademco Express V V V 1 4+2 Ademco Express V V V (8) V 2 3+1lStandard/1800/2300 V V (2) 1/ V (4) V V(5,6) V V 3 (NOT USED) 4 3+1lSndard/1900/1400 V V (2) 6/(4) V V V 5 (NOT USED) 6 4+1/Standard/180012300 V V (2) V V (4) V V (5) V V 7 (NOT USED) 8 4+1/Standard/1900/1400 V V (2) V (4) V V V 9 (NOT USED) A 4+2/Standard/1800/2300 V V (2) V V (4) V V (5) V V B (NOT USED) C 4+2/Sfardard/1900l1400 V V (2) V (4) V V V D (NOT USED) E Ademco Contact ID V V V V F (NOT USED) With 685-8 Line Card with Rev 4.4d software. With 9002 Line Card Rev 9035 software or 9032 Line Card with 9326A software. Rev. 4.0 software. FBI CP220FB Rec-1 1 Line Card with Rev 2.6 software and a memory card with Rev 3.8 software. Model 6500 with Rev 600 software. Model 6000 with Rev 204 software. With Rev B control card at Rev 1.4 software and Rev C line card at Rev 1.5 software. Model 2 only. Version 1.62 software. What is "Contact I.D.?" S Most digital receiving formats transmit simple information about the status of the site, i.e., alarm, trouble, supervisory, battery fail, etc. Contact I.D. is a transmission format enabling transmission of alarm and trouble conditions on a bi-point basis. Three groups of information are transmitted to the central station: a four-digit account code, a group number (00 to 99), and the device or zone number (000-999). Each of these three information groups is programmable. Because of the virtually unlimited number of combinations, the number of systems, points and/or zones transmitted is boundless. LOCAL AREA NETWORK APPLICATION The NOTIFIER UDACT (Universal Digital Alarm Communicator Transmitter) provides the means to create a powerful, low cost, local area network solution for any application involving multiple facilities spread over a small geographic area, such as a college campus. Compatible NOTIFIER fire control panels (System 500, System 5000, AFP-200, AFP-300, AFP400, AFP1010, AM2020), NOTIFIER UDACTs, standard public switched telephone network, and a low-cost digital receiver combine to solve what has in the past been impossible to do without incurring high costs. The UDACT, when used in the contact I.D. format, transmits detailed system status via the standard public switched telephone network to a digital receiver. The telephone network becomes the network gateway" from the FACP to the digital receiver and to an optional UniNet monitor. In the example shown on the attached page, separate phone lines within each facility tie independently to the UDACT and modem. For example: In this type of configuration, the maximum number of zones/points to be reported is 100,000. ' Applications include: hospitals, college campuses, shopping malls, prisons, airports, grouped government facilities, power plants, large commercial facilities and much more. In addition, the control panels may be networked using NOTI•FIRE•NETTM (see DN-4644). In this configuration, a single UDACT can be used to report uup to 2040 separate points and panel statuses. WIDE AREA NETWORK APPLICATION Imagine an application which requires the status of a fire system to be clearly visible for appropriate response/action, yet the monitored facility is located thousands of miles away from the monitoring center. These applications have in the past been out of reach using existing technology, but today are possible with the NOTIFIER WAN. The NOTIFIER UDACT provides the means to create a unique, flexible, low cost, wide area network solution for any application involving multiple facilities distance by a large geographic area, such as facilities located in various states spread across the continental United States. NOTIFIER WANs are created by using compatible NOTIFIER fire control panels (System 500, System 5000, AFP-200, AFP-300, AFP-400, AFP1010 and AM2020), a NOTIFIER UDACT, the standard public switched telephone network and a low-cost digital receiver. Reporting the general system status or the specific status of any monitored point in any facility to one central location is made simple. Controlling the system in this configuration is also made simple by utilizing the NOTIFIER UniNet, which is network compatible. In the example shown, separate phone lines within each facility tie independently to the UDACT and modem. For example: 4-Digit Acct Code Group No. In this type of configuration, the maximum number of zones/points to be reported is 100,000 and the number of moni- tored facilities is 99. Both the number of points and the number of facilities to be monitored increase when a four-digit account number is applied (as with conventional Central Station facility assignments) as well to expand the network! Multiple response centers are possible, one may be the local monitoring central station facility required by local codes! ordinances. The other monitoring station, as an option, may be located wherever compatible telephone networks exist. DN-4867 - Page 3of6 Building No. FACP Type 4-Digit Acct Code Group No. Device/Zone Range A AM2020 0001 00 00 001 to 00 999 0001 01 01 000 to 01 999 0001 02 02000to02 040 B AFP1010 0002 03 03 001 to 03 396 C AFP-200 0003 04 04001 to 04 089 D System 5000 0004 05 05 001 to 05 120 E System 500 0005 06 06 001 to 06 016 Building No. FACP Type Device/Zone Range A AM2020 0001 00 00 001 to 00 999 0001 01 01000 tool 999 0001 02 02 000 to 02 040 B AFP1010 0002 03 03 001 t003 396 C AFP-200 0003 04 04 001 to 04 089 D System 5000 0004 05 05 001 to 05 120 E System 500 0005 06 06 001 to 06 016 — Building A Building C listed I Building UL ti I AFP1010 AFP-200 Primary I il Control I .,IModemI II!flIDII Modem Station [V (if required) I _i-i-I1:iI UDACT UDACT UDACT tl Modem 19 Local 0 Telephone Central ice Z Network I Building D Building E _____ _____ o UDACT I5OOO 3 13 PHONE LINES Z5 cn S5OO Security Building I UniNet 0 (p 0 0) . . - - - - - -Building A Building C I AM2020 Building B AFPIOIO AFP-200 listedUL Primary Control Station (if required) Building E Building D Local ' A NOTI• FIRE. NETTM Telephone ' Communications Line AFP-400 AFP-300 Central Office L 11:11 INA Network -- ME 1UDACT Central Station Receiver .Net Security Building I PHONE LINES 17 Video Printer Terminal L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - F 0 F z . . . WIDE AREA NETWORK CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING. BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No, 7300-0028:174 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 DESIGN: Model UDACT digital alarm communicator transmitter with Model ABS-BR (optional) enclosure. The unit is used to transmit system status to central station via a standard two wire telephone switching network. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 21.2 - 28.2 VDC, 40 mA standby, 75 mA alarm, 100 mA trouble. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. 0 MARKING: Listee's name, model number and UL label. APPROVAL: Listed as digital alarm communicator transmitter for use with separately listed compatible control units. 08-31.94 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 5 Date Issued: MAY 2, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager 31981558.jpg 0 Li F HOLD FOR STATUS i D I CONTRAST ADJUST HOLD FOR I LAMP EST I GLOBAL I ACKNOWLEDGE 5ILENCEJ RESET O LCD-8OTM - 3198Id81nq __ [IiI LllLi LCD-80 with ABF-11 S (a NOTIFIER® GENERAL The LCD-80 is an 80-character, backlit LCD display annunciator for the NOTIFI ERAM2O2O, AFP1 010, NFS-640, AFC-600, AFP- 400, AFP-300, AFP-200, System 5000, and System 500 fire alarm control panels. Up to 32 LCD-80s may be connected onto the two-wire EIA-485 port. The LCD-80 has two basic modes of operation, Terminal" and "ACS" mode. The LCD-80TM shares all the features of the LCD-80, but only utilizes "Terminal" mode, where it mimics the panel display. COMMON FEATURES 80-character Liquid Crystal Display (20 characters x 4 lines), backlighted. Control switches for System Acknowledge, Signal Silence and System Reset. Time and date display field. Enable Key switch and phone jack options. Can be remotely located up to 6,000 ft. (1828.8 m) from the control panel. Local piezo sounder with alarm/trouble resound. Flush/surface/panel mount option. Optional RPT-485 repeater increases the distance and num- ber of LCD-80s in a system (see RPT-485 data sheet). Optional transmission over fiber optics (see RPT-485 data sheet). ACS MODE When operated in "ACS" mode, the LCD-80 provides a remote or local digital display and printer interface for the System 5000 and System 500. For the AM2020, AFPI 010, NFS-640, AFC- 600, AFP-400, AFP-300, and AFP-200, the LCD-80 provides a vectored annunciation capability. Individual devices/zones can be installer-defined to only display and print at specific locations (EXAMPLE: A maintenance office receives only non-alarm point activations. These inputs could be sump pump on, high water, backupAHU on, low temperature in freezer, etc.). Alarm/trouble count. Custom "normal" message. European option: first alarm/last alarm/alarm count. Field-programmable messages from CRT or PC-compatible computer (PK-LCD-80 Programming Kit required). EIA-485 interface: up to 32 per system. Printer output port: RS-232, compatible with PRN Series printers. Field-programmable messages in nonvolatile memory in two options: 128 points, 40 character labels; or 256 points, 20 character labels. Internal nonvolatile clock for time and date in ACS mode. AM2020, AFP1 010, NFS-640, AFC-600, AFP-400, and AFP- 300 "vectored" printer capability. Can be mounted in a System 5000 cabinet module position. LCD-80 and LCD-80TM Liquid Crystal Displays Section: Annunciator Control Systems California State Fire @(9 A Marshal 7120-0028:156 LISTED CS100 IV1EA S635 290-91-E (LCD-80) 289-91-E (LCD-80) 104-93-E Vol. III (LCD-80TM) Approved 317-01-E (NFS-640) (LCD-80, except NFS-640) TERMINAL MODE In 'Terminal" mode, the LCD-80 mimics the AM2020, AFP1 010, NFS-640, AFC-600, AFP-400, AFP-300 and AFP-200 displays. Up to 32 LCD-80s can annunciate and provide remote reset, acknowledge, and silence of the control panel from remote loca- tions. The DIA-1 010 and DlA-2020 (Display Interface) include a Terminal mode driver port for LCD-80s in Terminal mode. The Terminal mode port is standard on the NFS-640, AFC-600, AFP- 400, AFP-300, and AFP-200 main PC/CPU boards. Displays device type identifiers. Device and zone custom alpha labels. lime/date and Device address. May operate in addition to CRT. No programming necessary. LCD-80 displays time, date, and custom messages received from AM2020, AFP1 010, NFS-640, AFC-600, AFP-400, AFP-300, or AFP-200. January 18, 2002 L!1I d5g This document is not intended to be used for installation purposes. We try to keep our prod- uct information up-to-date and accurate. We cannot cover all specific applications or antici- I ISO 9001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 I NOTI Fl ER 12 Clintonville Road, Northford, Connecticut 06472 FIVCINEERING & MAN-UFACTURINI Made in the U.S.A. DN-3198 •01/18/02 - Page 1 of 2 The LCD-80 in ACS Mode EIA-232, 4 wires 50 ft. (15.24 m) max. PRN Printer [1 System 5000 with panel-mounted LDC-80 3198d101.wmf System 5000, System 500, AM2020, AFP1010, NFS-640, AFC-600, AFP-300I400, AFP-200, or NCA LCD-80 is 8.25" (20.96 cm) high, 4.375" (11.11 cm) wide, and 1.75" (4.45 cm) deep. Up to 32 LCD-80s may be used on one EIA- 485 circuit. NOTE: Must have sufficient regulated 24 volt power Certain NOTIFIER systems may have lim- its to the amount of LCD-80s with ACKISTEP, Sig- nal Silence, and Reset switches. LCD-80 mounts with any CHS-4 chassis slot. The LCD-80 may display all System 5000 cir- cuits. Alternately, it may display up to 192 AIM- 200 points and two rows of modules. 6,000 ft. (1828.8 m) maximum total wire length EIA-485 EIA-485 EIA-485 (2 wires) (2 wires) (2 wires) 24 VDC / 24 VDC 24 VDC (2 wires) V (2 wires) (2 wires) I i-I -I II rn ml ml TO T_ T _ PRN LCD-80 PRN LCD-80 PRN LCD-80 II PRINTER PRINTER PRINTER U ft Eo ii UI The LCD-80 or LCD-BOTM in Terminal Mode I 6,000 ft. (1828.8 m) maximum wire length ABF..1 OB —The ABF-1 DB is a semi-flush-mount backbox for Terminal Mode EIA-485 between each LCD-80 the NOTIFIER LCD-80 Series (2 wires) I I j I J Annunciator. The ABF-1DB mounts one LCD-80(TM). It in- III 24 VDC I cludes an attractive smoked- (2 wires) I I l I glass door with NOTIFIER iI ke4ock. LCD-80(TM) LCD-80(TM) LCD-80(TM) Dimensions, BOX only: 9.938" (25.24 cm) high, ElA-232 AM2020, Terminal Mode ElA-485 return (2 wires) 4.625" (111.75 cm) wide, Printer Port AFP1010, 2.5" (6.35 cm) deep. NFS-640, Up to 32 LCD-80(TM)s may be used in a continuous Dimensions, DOOR only: AFC-600, AFP300/400, 4-wire loop (verify sufficient 24 VDC available). 10.713" (27.21 cm) high, orAFP-200 Each may haveACK/STEP, SIGNAL SILENCE, and 6" (15.24 cm) wide, PRN Printer SYSTEM RESET switches. Displays all analog, addressable points. 0.75" (1.9 cm) deep. No programming required for LCD-80(TM)s RELATED OPTIONS PK-LCD-80 (order VERIFIRE-CD): Off-Line Programming Kit for LCD-80. Allows PC programming messages when LCD-80 is used in the ACS mode. CCM-1: Converter Module. Required for terminal mode opera- tion on olderAM2020s orAFP101Os that do not include the DIA- 2020 or DIA-1 010 Display Interfaces. Also required forAM2020 and AFPI 010 systems which require a CRTwith keyboard. Uses one ICA-4L chassis slot or two CHS-4 chassis slots. SeeACS Series (DN-524) or ONYXTM ACS Series (DN-6862) data sheets for additional information on items below. ABF-1 DB: Semi-flush box with alternative smoked-glass door, any keylock. ADP-4: Annunciator Dress Plate, gray. Allows panel mounting of up to four LCD-80(TM) modules in a CAB-3 Series cabinet. ADP-4B: Annunciator Dress Plate, black. Allows panel mounting of up to four LCD-80(TM) modules in a CAB-4 Series cabinet. Page 2 of 2 - DN-3198 .01/18/02 ABF-1 B: Annunciator Flush Box, 9.938" (25.24 cm) high, 4.625" (11.75 cm) wide, and 2.5" (6.35 cm) deep. OrderAKS-113 key switch and APJ-1 B phone jack if desired. Can also be mounted in ABF-2B orABF-4B annunciator backboxes. ABS-ITB: Deep Surface Backbox (mounts one LCD-80/-80TM). AKS-1 B: Key Switch (black) to enable/disable controls when mounted inABF orABS-1TB. APJ-IB: Annunciator Phone Jack, black. Mounts toABF flush box orABS-1TB. PRN Series: 80-Column Serial Printer (see PRN data sheet). RPT-485W: ElA-485 Wire Repeater. Increases wire distance between LCD-80s in ACS mode (see RPT-485 data sheet). RPT-485F: EIA-485 Fiber-Optics Repeater. Increases distance and converts ElA-485 wire to fiber-optics in ACS mode (see RPT- 485 data sheet). CALIFORNIA DEPARTMENT OF FORESTRY & ARE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S. LISTING No CATEGORY USTEE: DESIGN: 7120-0028:156 Page 1 of 1 Annunciators Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653. Contact: Larry Flood (203) 484-1200 Model ACS annunciator control system. Refer to listee's data sheet for additional detailed product description and operational considerations. Unit consists of the following modules: t ACM-1 6AT AEM-16AT AEM-32A, ACM-32A AFM-16AT, AFM-32A, AFM-16A ABM-1 6A1, ABM-32A ABS-1, ABS-2 ABF-1, -1 D, -2, -2D, -4 ADP-4 A KS-i LCD-80, -80 TM LDM-32 LDM-E32 LDM-R32 ACM-8R Control Module Expander Module Control Module Fixed Module Blank Module Enclosures (Surface) Enclosures (Flush) Dress Panel Key Switch Control Panel Lamp Driver Module Lamp Driver Expander Lamp Driver Expander (Relay) Mappable Relay Control Module INSTALLATION: MARKING: APPROVAL: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as an annunciator system when used in conjunction with separately listed compatible fire alarm control units. Rev. 02-13-96 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date issued: MAY 21 2001 Listing Expires June 30, 2002 S Authorized By: BEN HO, Supervising Deputy Program Manager December 15, 2000 DN-6714 H-200 FSI-751 and FSP-751/751T Low-Profile Intelligent Plug-in Smoke Detectors with FlashScan® Section: Intelligent/Addressable Devices S The NOTIFIER FSP-751 (photo) and FSI-751 (ion) are ana- log, addressable, low-profile (height measures only 1.667 42.164 mm) smoke detectors designed for the entire line of intelligent systems from NOTIFIER. The FSP-751T photo model includes a built-in thermal (heat) detection device. If either condition (smoke or heat) is detected, the device will alarm. The addressability of the FSP-751 and FSl-751 enables the control panel to provide firefighters with a pinpoint descrip- tion of where the fire is located. The FSP-751 and FSI-751 are also analog devices. The control panel is capable of not only knowing the detector's location but exactly how much smoke is in the chamber of the detector. The detector may be set for different sensitivity settings appropriate to the en- vironment of its location. Analog devices continually send obscuration values to the con- trol panel. These values may be gathered so as to allow the control panel to determine if a detector has accumulated an excessive amount of dirt or dust. A "maintenance" required indication allows the installer to clean the smoke detector be- fore an unwanted false alarm occurs. The FSI-751 Intelligent Ionization Sensor incorporates a unique single-source chamber design to respond quickly and dependably to a broad range of fires. The FSP-751 Intelligent Photoelectric Sensor's unique opti- cal sensing chamber is designed with superior signal to noise ratio. The optical chamber is engineered to sense the pres- ence of smoke produced by a wide range of combustion. sources. FlashScan® (patent pending) is a new communication pro- tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog intelli- gent devices and certain NOTIFIER systems. Intelligent de- vices communicate in a grouped fashion. If one of the de- vices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. FlashScan® is a registered trademark of NOTIFIER. FEATURES Sleek, low-profile design (height only 1.66/42.164 mm). Common base for both photo and ion detectors. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Rotary 01 to 159 address switches (01 to 99 on traditional systems). Optional remote, single-gang LED accessory (RA400Z). Dual LED design provides 360° viewing angle. California State Fire Marshal 7272-0028:206 (FSP-751/-751T) LISTED CS308 7271-0028:201 S1115 (FSI-751) MARYLAND MEA State Fire Marshal <i 277-99-E 2020 (FSI-751) Approved (FSP-751/ 2013 (FSP-751/-751T) - -751Tonly) Visible bicolor LEDs blink green every time the detector is addressed, and illuminate steady red on alarm. Walk test with address display (an address of 121 will blink the detector LED: 12-(pause)-1) (FlashScan® systems only). Built-in functional test switch activated by external mag- net. Optional relay, isolator, or sounder bases. Listed to UL 268. SPECIFICATIONS Size: 1.66" (42.16 mm) high x4.1" (104.14 mm) diameter. Shipping weight: 3.6 oz. (104 g). Operating temperature: 0°C to 49°C (32°F to 120°F). This document is not intended to be used for installation purposes. We try to keep our I product information up-to-date and accurate. We cannot cover all specific applications or I anticipate all requirements All specifications are subject to change without notice. ISO 9001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 EMN dl u N OTI Fl E R° 12 Clintonville Road, Northford, Connecticut 06472 ENGINFIRINO & MANUFACTURING DN-6714 .12/15/00 - Page 1 of 4 UL listed velocity range: ION: 0 - 1500 fpm (0 - 7.62 m/ PRODUCT LINE INFORMATION sec). PHOTO: 0 - 4000 fpm (0 - 20.32 mlsec). Mode! Description Relative humidity: 10% - 93% noncondensing. FSI-751 Low-profile intelligent ionization sensor. Must ELECTRICAL SPECIFICATIONS: be mounted to one of the bases listed below. Voltage range: 15-32 volts DC peak. FSP-751 Low-profile intelligent photoelectronic sensor. Standby current - ION: 200 pA @ 24 VDC (without corn- Must be mounted to one of the bases listed be- munication); 300 pA @ 24 VDC (one communication every OW. 5 seconds with LED enabled). FSP-751T Same as FSP-751 but includes a built-in 135°F Standby current - PHOTO: 250 pA @ 24 VDC (without (57°C) fixed-temperature thermal device. communication); 360 pA @ 24 VDC (one communication BASES: every 5 seconds with LED enabled). B7IOLPBP Standard U.S. low-profile base, pkg. of 10. LED current (max.): 6.5 mA @24 VDC ('ON"). B50IBP Standard European flangeless base, pkg. of 10. Air velocity ratings: FSP-751 & FSP-751T to 4,000 ft/mm. B50IBH Sounder base, includes B501 base above. (1219.2 m/min.). FSI-751: to 1,500 ft./min. (457.2 rn/mm.). B501 BHT Same as B501 BH, but includes temporal sounder. BASES AVAILABLE: B224RB Intelligent relay base. B7IOLP: 6.1(154.94 mm) diameter. B224B1 Intelligent isolator base. Isolates SLC from loop B501: 4.1" (104.14 mm) diameter, shorts. B50IBH or B50IBHT: Sounder base assembly. Includes ACCESSORIES: B501 base. SDG-773 Smoke Detector Guard. This guard is mechani- B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 cally compatible with both FSI-751 and FSP-751 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC detectors. It is UL-compatibility listed with the resistive; 0.3 A @ 110 VDC inductive; 1.0 A @30 VDC in- FSP-751 (file UL S5515). It is NOTUL-compat- ductive. Dimensions: 6.2" (157.48 mm) x 1.2" (30.48 mm). ibility listed with the FSI-751. B524B1 Isolator Base: Dimensions: 6.2" (157.48 mm) x FIIO Retrofit replacement flange for BX-501 base. 1.2" (30.48 mm). Maximum: 25 devices between isolator Converts BX-501 base for use with FlashScan bases. detectors. Duct applications: FSP-751 and FSP-7511 are Listed for Remote LED annunciator. 3 - 32 VDC. Fits use in air ducts. See Duct Application Guide A05-1004 for U.S. single-gang electrical box. details on pendant-mount applications. NOTE: These prod- SMK400 Surface mounting kit provides for entry of sur- ucts are NOT Listed for use inside a duct smoke detector face wiring conduit. For use with B501 base housing. only. INSTALLATION RMK400 Recessed mounting kit. For use with B501 base The FSP-751 and FSI-751 plug-in detectors use a separate only. base to simplify installation, service, and maintenance. A SMB600 Surface mounting kit for use with B71OLP. special tool allows maintenance personnel to plug in and re- M02-04-01 Test magnet. move detectors without using a ladder. M02-09-00 Test magnet with telescope stick. Mount base on a box which is at least 1.5" (38.1 mm) deep. XR-2 Detector removal tool. Allows installation and/ Suitable mounting base boxes include: or removal of FlashScan Series detector heads 4" (101.6 mm) square box, from base in high ceiling installations. 3-1/2" (88.9 mm) or 4" (101.6 mm) octagonal box. XP-4 Extension pole for XR-2. Comes in three five- Single-gang box (except relay or isolator base). foot sections. With B50IBH base, use a 4(101.6 mm) square box. *Supported by B7IOLP and B501 bases only. With 8224R8 or B224B1 base use a 3-1/2" (88.9 mm) . octagonal box or a 4 (101.6 mm) octagonal or square / box. 17: SMOKE GUARD Cover 16 gauge perforated steel (3/16 [4.7625 mm] dia -. perforations on 1/4 [6.35 mm] staggered centers) 51% open SDG-773 is 3(76.2 mm) deep by 7" (177.8 mm) wide. OPTIONAL Frame: 3/4" x 3/4(19.05 x 19.05 mm) angle, 14 gauge solid SDG-773 Smoke Guard steel. (t905 cm) ,--------------------------------------------------------------, (1.905cm) All guards are supplied with the following: 7° (17.78 cm) Guards fasten to mounting frame with No. 10/24 x 3/8" z4LzI: LLL (9.525 mm) long Allen-head screws (10/24 spanner-head I screws and tool option at extra cost). ceiling or Wall Standard finish: 'Cool Tan" baked enamel. MODEL NO. 11.12 cm): SDG-773 MOUNTING DIAGRAM SDG-773 Smoke Guard 4762sdgn.wml Page 2of4 - DN-6714 12/15/00 PAINTED \ SURFACE" PAINTED SURFACE 0 DETECTORS, EXPLODED VIEW SE I SOR L i - COVER Li f REMOVAL TABS SENSING CHAMBER fIilU JW n 1 6714expl.wnF FSP-751 and FSP-751T Photo _________SENSOR COVER /1 H COVER Lci ttJ REMOVAL TABS SENSOR SCREEN SENSOR CONTACTS SENSING SENSING ENSING CHAMBER 6714 exp2.w1 FSI-751 Ion TEST MAGNET POSITIONING LED 2 U LED STATUS INDICATORS MAGNET TEST MARKER L3 uI 1L PAINTED TEST SURFACE 6714rneg1.wrnf MAGNET TEST MARKER EJ p ft, M2TH I 1/ II PAINTED 6714ng3.tif SURFACE Ak FSP-751 and FSP-751T Photo AL FSI-751 Ion DN-6714 • 12/15/00 - Page 3 of 4 REMOTE ANNUNCIATOR /AThiONTY S. E, 0 WIRING DIAGRAMS REMOTE ANNUNCIATOR +1 I— Listed Compatible CONTROL 1 051! PANEL OPTIONAL RETURN LOOP -------------------------------------------------------- A FSP-751 and FSP-751T Photo A FSI-751 Ion Page -4 0t4 - DN-6714• 12/15/00 CALIFORNIA DEPARTMENT OF F(fliE$TflV & FIRE PRQTCTIO OFFICE OF THE STATE FIRE MARSHAL FflE ENGtNEI BUILLING TIA1EALS LISTING PROGRAM S LISTING SERVICE LISTING No, 7272<U2:2)6 I C I C4TEGO4Y: 1'Ijk S tu Lf$TLC A Pi'y Cnrn y, Oi it-F Nor T 01.472•161-3 Cuitct: Lu:rj 233: 1'11 JO DESIGN: M,dFSP-7I, HrX71, F$P11T t F+.71 '-c ritVp dctctys. \1ipI FSP.?iT a s pp1 't;1 h cist I h bi:t rrr k rr intrd+'5 Lc Ju Nit ftn tinI uIdi1d roct 24 VDC INSTALLATION- In lrinte ir i'in, in r.-ablp t . ARJIING: I ts nm'o rIuc JL fI;e1, APPROVAL: LiL I u phi. crt ie mkt tcor kr t tlt istc d i:J Irc j1utr ejnttU jj+j.. tke I 17I sk fi u)ii iw yiI e Ji;t :uL:krr 'ti )iik: t•m Mode I X7I s cr nprt pit rpm, ico cf u:.n chn? tJa 1rr t ppIicrt. CSF1 Fire Eng t1ifvj iI tiGJ rufl t I; iji r:t ir flC);rl io (t On 1(m;. Ti ht_t i rrnTnc7dn f tflP item );tU1. IS flj1 )fl* mrItI fpqui tb or IIair c:cr i. Fi(or tc: ::e& nstI1i nicr jitth rnn urce. DECEMBER. 31 2001 F c:j rs Juno 30, 2002 Authaivzed &y: D'ANE K. i%REND, SnrDpwy Prrwi October 9, 2001 DN-6716. 14210 (0 NOTIFIER® FST-751 Series Intelligent Thermal (Heat) Detectors with FIashScan Section: Intelligent/Addressable Devices S GENERAL The FST-751 Series intelligent thermal detector is used with the intelligent NOTIFIER Fire Alarm Systems to mea- sure thermal levels caused by a fire and report the analog level of the thermal measurement to the control panel. The use of analog information provides significant ben- efits to the end user, installer, and service personnel in ways which are not possible with a conventional type sys- tem. Since this detector is addressable, it helps firefighters to more quickly locate a fire in its early stages. FlashScan® (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelligent devices. Intelligent devices communi- cate in a grouped fashion, if one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. FEATURES Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Rate-of-rise model (FST-751R), 15°F (8.3°C) per minute. Factory preset at 135°F (58°C). Addressable by device. Direct 01 - 159 entry of address (01 - 99 on traditional systems). Two-wire loop connection. Visible LEDs "blink" every time the unit is addressed. 360°-field viewing angle of the visual alarm indicators (Two bicolor LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type iden- tification. Remote test feature from the panel. Built-in functional test switch activated by external mag- net. Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). Low standby current. Listed to UL 521. Built-in tamper-resistant feature. Designed for direct-surface or electrical-box mounting. Sealed against back pressure. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelectric, ioniza- tion and thermal sensors. ban • SEMS screws for wiring of the separate base. & 9 California te !::8:196 Approved LISTED MARYLAND S747 State Fire Marshal M FA 2011 - 278-99-E CS630 94-5V plastic flammability rating. Remote LED output connection to optional RA400Z remote LED annunciator. Optional sounder, relay, and isolator bases. Optional recessed (RMK400) or surface (SMK400) base mounting kits. APPLICATIONS Use thermal detectors for protection of property. For further information call NOTIFIER for manual 56-407- 00, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. CONSTRUCTION These detectors are constructed of Bayblend® in an off-white color. The FST Series plug-in intelligent thermal detector is de- signed to commercial standards and offers an attractive ap- pearance. INSTALLATION The FST Series plug-in intelligent thermal detector uses a separate base to simplify installation, service, and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on box which is at least 1.5" (38.1 mm) deep. Suitable boxes include: FlashScan® is a registered trademark of NOTIFIER. Bayblend® is a registered trademark of Bayer Corporation. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484.7118 . cj N OTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 ENGINEERING & MANUFACTURING DN-6716 .10/09/01 —Page 1 of 2 S 4" (101.6 mm) square box. 3-1/2' (88.9 mm) or 4" (101.6 mm) octagonal box. Single-gang box (except relay or isolator base). With B50IBH or B50IBHT base, use a 4" (101.6 mm) square box. With B224RB or B224B1 base, use a 3-1/2' (88.9 mm) or 4" (101.6 mm) octagonal box, or a 4" (101.6 mm) square box. NOTES: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring °T-taps" or branches are permitted for Style 4 (Class 'B") wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations between isolator modules and iso- lator bases. OPERATION Each FST Series uses one of 159 possible addresses (99 on traditional systems) on a control panel SLC loop. It responds to regular polls from the control panel and it reports its type and status, including the analog level of its heat-sensing elements. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm analog level. It blinks its LEDs when polled and turns the LEDs on when com- manded by the panel (detector blink is optional). The FST Series offers features and performance that represent the latest in thermal detector technology. SPECIFICATIONS Size: Diameter installed in B7IOLP: 6.1" (154.94 mm); Diameter installed in B501: 4.1(104.14 mm). Height: 1.66" (42.16 mm). Weight: 5 oz. (150 gm). Operating temperature: —4°F to 100°F (-20°C to 38°C). Operating humidity range: 10% to 93% relative humidity, noncondensing. Operating voltage/current range: 15 - 28 V (Peak DC), 5 mA current for visible LEDs latched on. Detector standby current: 300 pA @ 24 VDC (one com- munication every 5 seconds with LED blink enabled). For bases B224RB or B224B1: < 700 pA @ 24 VDC (includes detector). Sensor: electronic, dual thermistors. Fixed temperature setpoint: 135°F (57°C). WIRING DIAGRAM REMOTE ANNUNCIATOR -I -I Rate-of-rise option: 15°F (8.3°C) per minute. Detector spacing: UL approved for 50 ft. (15.24 m) cen- ter to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. B224RB relay base: Screw terminals: up to 14 AWG (2.00 mm2). Relay type: Form-C. Ratings: 2 A @ 30 VDC resis- tive; 0.3 A @ 110 VDC inductive; 1.0 A @30 VDC inductive. Dimensions: 6.2" (157.48 mm) diameter x 1.2" (30.48 mm) high. See Note 2 (left column). B224B1 isolator base: Dimensions: 6.2" (157.48 mm) diameter x 1.2" (30.48 mm) high. Maximum: 25 devices between isolator bases. See Note 2 (left column). PRODUCT LINE INFORMATION Model Description FST-751 Intelligent thermal sensor. FST-751R Intelligent thermal sensor with rate-of-rise fea- ture. BASES: B7IOLPBP Standard U.S. style low-profile base, package of ten (10). B50IBP Standard European flangeless base, pack- age of ten (10). B50IBH Sounder base, includes B501 base above. 24 VDC, 85 dBA internal horn. B501 BHT Same as B501BH but with temporal pattern sounder. B224RB Intelligent relay base. B224B1 Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: RA400Z* Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. SMK400 Surface mounting kit provides for entry of sur- face wiring conduit. For use with B501 base only. RMK400 Recessed mounting kit. For use with B501 base only. M02-04-00 Test magnet. 'Supported by B501 and B7IOLP base only. ARCHITECTURAL & ENGINEERING SPECIFICATIONS Specifications are available on these and all NOTIFIER products. Please contact NOTI Fl ER. + Control Panel Page 2 012 - DN-6716 - 10/09/01 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7270-0028:196 Page 1 of 1 CATEGORY: Heat Detector LISTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 DESIGN: Models FST-751 (fixed temperature) and FST-751 R (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 1350 F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Inc. Label APPROVAL: Listed as heat detectors for use with Model B501 or B71OLP base (CSFM Listing No. 7300-0028:173) and listee's separately listed compatible fire alarm control units. 08-06-99 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Li 0 Date Issued: MAY 4, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager April 22, 2002 DN-6886 H-113 (j) ® NOTIFIER I F I E R Very Intelligent Early Warning (VIEW®) LASER Smoke Detector with FlashScan® Section: Intel ligentlAddressable Devices C GENERAL The NOTIFIER FSL-751 VIEW® Laser Detector provides a revolutionary advance in early warning smoke detection tech- nology. The unique design of this detector, combined with en- hanced AWACSTM algorithms in the NOTIFIER AFP-300, AFP-400, AFC-600, NFS-640, or NFS-3030 control panel, al- lows smoke detection sensitivity that is 10 to 50 times higher than present photoelectric technology. Because of this high sensitivity, the FSL-751 can provide very early warning of slow smoldering fires. Its performance is comparable to present aspiration technology, at a substantially lower installed cost. The FSL-751 uses an extremely bright laser diode, combined with special lens and mirror optics (U.S. patent pending), to achieve a signal-to-noise ratio that is much higher than tradi- tional photoelectric sensors. In addition, the tightly focused light beam, combined with the AWACSTm algorithms (U.S. patent pending), allow the system to differentiate between dust and smoke particles. Because of this differentiation, the FSL- 751 can be set to extremely high sensitivity, yet can reject false signals caused by larger airborne particles such as dust, lint, and small insects (U.S. patents pending). The FSL-751 is an intelligent (analog/addressable) detector. Using CLIP mode, up to 99 FSL-751 detectors may be in- stalled per loop. On FlashScan® systems (AFC-600, NFS- 640, NFS-3030), up to 159 addresses are available. The FSL- 751 may be mixed in any combination with other NOTIFIER intelligent sensors on the same loop and is quickly installed using the panel autoprogram feature. The FSL-751 provides dual bi-color LEDs, which blink green in normal operation and illuminate steady red in alarm. FlashScan® (U.S. Patent 5,539,389) is a new communica- tion protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intel- ligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Using the enhanced AWACSTM algorithms, the VIEW® sys- tem provides drift compensation (meeting UL requirements as a calibrated sensitivity meter), maintenance alert (3 levels), selection of 9 alarm levels and 9 pre-alarm levels, and report of drift compensation used and recent peak values. The sys- tem includes a self-learn sensitivity adjustment to set the pre- alarm level just above the peak levels sensed over long peri- ods of time for each detector's actual environment. The sys- tem includes multi-detector algorithms (U.S. patent pending) that permit one sensor to consider readings from adjacent sensors to provide faster detection of fires. FEATURES Very Intelligent Early Warning (VIEW®) smoke detection. Advanced laser light source and patented optical design. California U1 ULC S State Fire 7272-0028:218 LISTED CS308 Vol. 2 (FSL-75 IA) S1115 MEA FM 3-02-E (AFP-300/-400, AFC-600) Approved 447-99-E (AFC-600) (AFP-3001-400, AFC-600) - 5306pl - . . ..... .. - — L.I - - - FSL-751 with B7IOLP base (top), B501 base (middle), and RMK400 recessed mounting kit (bottom). Sleek low-profile housing (1.66/42.164 mm height). NOTIFIER Analog Addressable communications protocol provides extremely reliable operation proven in millions of worldwide detector installations. Sensitivity to 0.03%/foot. Rotary DECADE address switches. Set 01 —99 on legacy systems and 01 - 159 on FlashScan® systems (AFC-600, NFS-640, or NFS-3030). These switches allow quick se- lection of address without resorting to binary switches, spe- cial programmers, or bar coding devices. AWACSTM is a trademark and FlashScan® and VIEW® are regis- tered trademarks of NOTIFIER. NOTIFIER® is an operation of Honeywell. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or IS09001 anticipate all requirements. All specifications are subject to change without notice. ____ For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 I 1 NOTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 FrILERlNC & MANUFACTIIRINI ON-6886• 04/22/02 - Page 1 of 3 I Dual bi-color (red/green) LEDs flash green when Normal and are steady red in Alarm. Compatible with the NFS-3030, NFS-640, AFC-600, AFP-400, and AFP-300 (all software releases). Dual LED design provides 3600 viewing angle. Built-in magnetic test switch, or automatic test commanded from panel. Optional relay, isolator, or sounder bases. SPECIFICATIONS Operating voltage range: 15 to 28 VDC. Maximum standby current: 230 pA @ 24 VDC (no commu- nication). Maximum average standby current: 255 pA @ 24 VDC (one communication every 5 seconds with LED blink enabled). B224RB/B224Bl: <700 pA @ 24 VDC (includes detector). Maximum alarm current: 6.5 mA @ 24 VDC (LED "ON"). Operating humidity range: 10% to 93% Relative Humidity, non-condensing. Operating temperature range: 00 to 49°C (32° to 120°F). Loop resistance: 40 ohms maximum. Dimensions: Height: 1.66 inches (42.16 mm) installed in B71OLP base. Diameter: 6.1 inches (154.94 mm) installed in B71OLP base; 4.1 inches (104.14 mm) installed in B501 base. Weight: 3.6 oz. (102 g). BASES AVAILABLE: B7IOLP: 6.1 inches (154.94 mm) diameter. B501: 4.1 inches (104.14 mm) diameter. B50IBH: Sounder base assembly. Includes B501 base. B224RB Relay Base: Screw terminals: Up to 14AWG (2.00 mm2). Relay type: Form-C. Rating: 2A@ 30 VDC resistive; 0.3A@ 110 VDC inductive; 1.0A@ 30 VDC inductive. Di- mensions: 6.2 in. (157.48 mm) x 1.2 in. (30.48 mm). B224B1 Isolator Base: Dimensions: 6.2 in. (157.48 mm) x 1.2 in. (30.48 mm). Maximum: 25 devices between isolator bases. RECOMMENDED COVERAGE PER DETECTOR In order to support sophisticated smoke/dust discrimination algorithms (cooperating multi-detector), it is recommended that at least two FSL-751 detectors be installed in each room or enclosed area. Recommended coverage per detector is 400 square feet (37.16 square meters). INSTALLATION The FSL-751 plug-in detector uses a separate base to sim- plify installation, service, and maintenance. A special tool al- lows maintenance personnel to plug-in and remove detectors without using a ladder. Mount base on a box which is at least 1.5" (38.1 mm) deep. Suitable mounting base boxes include: 4" (101.6 mm) square box. 3-1/2" (88.9 mm) or 4" (101.6 mm) octagonal box. Single-gang box (except relay or isolator base). ORDERING INFORMATION FSL-751 Laser Detector, Intelligent laser sensor with FlashScan® capabilities. Mounts to one of the bases listed below. FSL-751A Canadian model. BASES: B7IOLPBP Standard U.S. low-profile base, package often (10). B50IBP Standard European flangeless base, package of ten (10). B50IBH Sounder base, includes B501 base. B224RB Intelligent relay base. B224B1 Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: FIIO Retrofit replacement flange for BX-501 base. RA400Z *Remote LED annunciator. 3-32 VDC. Fits U.S. single-gang electrical box. MOD400R Detector sensitivity test tool. Use with most ana- log or digital multimeters. Satisfies requirement of NFPA72 for sensitivity testing. SMK400 Surface mounting kit provides for entry of surface wiring conduit. For use with B501 base only. RMK400 Recessed mounting kit. For use with B501 base only. M02-04-01 Test magnet. M02-09-00 Test magnet with telescope stick. XR-2 Detector removal tool. Allows installation and/or removal of 700 Series detector heads from base in high ceiling installations. XP-4 Extension pole for XR-2. Comes in three 5-ft. (1.524 m) sections. *Supported byB71OLP and B5O1 bases only. REMOTE ANNUNCIATOR Listed Compatibie PANEL - OPTIONAL RETURN LOOP -------------------------------------------------------- Page 2 of 3 - DN-6886 04122/02 Wiring Diagram (standard base) FSL-751 DESIGN The FSL-751 incorporates an extremely bright laser diode and integral lens that focuses the light beam to a very small volume near the receiving photo sensor. The light then passes into a light trap and is absorbed. The photo sensor is activated by a scattering of smoke particles in this small-volume light beam. In a typical photoelectric detector, the light beam is very wide and can reflect off the chamber walls into the photo sensor because dust accumulation changes the wall color from flat black to gray. With the FSL-751,the concentrated light beam does not touch the walls, therefore it is much less susceptible to dust accumulation. Smoke scatters light in all directions and, in a typical photoelectric detector, only a small portion of that scattered light reaches the photo sensor itself. In the FSL-751, a special mirror reflects and concentrates most of the scattered light into the photo sensor. See laser detail drawings on this page. Compared to smoke, airborne dust particles are very large and very sparse. Since a) they are in motion; b) the illuminated volume is very small; and c) the FSL-751 flashes the laser only every few seconds; then the occasional dust particle cannot remain in the light volume for more than one or two samples. This transient signal from dust is the key to the dust discrimination performed by VIEW®. TEST LED LASER DIODE & SMOKE DIRECTION INTEGRAL LENS BAFFLES ASSEMBLY 5306ci2wmr CHAMBER COVER BUG SCREEN Mirror Detail 5306n,irwrnf MIRROR (SEE DETAIL AT RIGHT) PROTECTIVE HOUSING - SAFETY INTERLOCKS (4) SMOKE SENSING CHAMBER COVER/SCREEN SMOKE SENSING CHAMBER BASE NG CONTACT UG SCREEN ONTACTS TO IOUNTING RACKETS WOKE DETECTOR BASE DN-6886• 04/22/02 - Page 3 of 3 CIRCUIT BOAF PHOTO DIODE MJ )H'A LA)tMr OF rQ4$uy & f1 J1cE OF THE SrME FUE MA 1.. WuG uUIN(; t.A tHLS US TIN G LISTING SERVICE LFS'1E: RAT]!G . NSIA1 A11) Ir. i d i n AH H- : t r . N PAARTNT 14ti1 %vU ; . . :r 21, ;C ,.- •. . -•. : .' -- - -- - .. . ,.J_., -- - I -_:>r.r'-i - - --.•-.-.. -- -__ -. I -- - . .1 ...........- - -.I-. - -- - ,-, .- - .I - I -' --.:- ---• - - . - <- APRIl 20 2002 w30 2002 A:-.LJJy: D!.?\FK4RF1\L) - :r - Pf, - i Y - -- CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7300-0028:173 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 DESIGN: Models BX501, 136101-13, 13612LP, B614LP, B616LP and B71OLP detector bases. Referto listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. *kLF: 7300-1209:128 07-29-94 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 5 Date Issued: MAY 4, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager October 2, 2001 v DN-6724 • H-230 ® FCM and FRM Series NOTIFIER Control and Relay Modules with FlcishScan® Section: Intelligent/Addressable Devices C GENERAL FCM-1 Control Module - The FCM-1 Addressable Control Module provides NOTIFIER intelligent control pan- els a circuit for Notification Appliances (horns, strobes, speak- ers, etc.) or to monitor a telephone circuit. Addressability allows the FCM to be activated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1 Relay Module - The FRM-1 Addressable Re- lay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, damp- ers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between ana- log intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FEATURES Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM module requires power (for horns, strobes, etc.), audio (for speakers), or a telephone riser (for hand- sets). Internal relay feature available on FlashScan® sys- tems only. Integral LED blinks' green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFl). The FCM may be used to switch 24-volt NAC power, au- dio (up to 70.7 VRMS) or telephone. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan®, 01 - 99 on traditional systems. Speaker, audible/visual, and telephone applications may be wired for Class B or A (Style Y or Z). APPLICATIONS The FCM is used to switch 24 VDC audible/visual power, high-level audio (speakers), or control telephone devices. The FRM may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. & (9 0 LISTED C5669 S3705 FM Approved (See wiring diagram Fig. 5 for FRM-1) CONSTRUCTION The face plate is made of off-white Noryl®. Controls include two rotary switches for direct-dial entry of address (01-159). The FCM is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM provides two Form-C dry contacts that switch together. OPERATION Each FCM or FRM uses one of 159 possible module ad- dresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On corn- FlashScan® is a registered trademark of NOTIFIER. Noryl® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. California State Fire Marshal 7300-0028:202 MARYLAND lvi EA State Fire Marshal Permit #2020 457-99-E This document is not intended to be used for installation purposes. We try to keep our I product information up-to-date and accurate. We cannot cover all specific applications or I ISO 9001 anticipate all requirements. All specifications are subject to change without notice. I For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 93MI==1 N OTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 J ENGINEERING & MANUFACTURING DN-6724• 10/02/01 - Page 1 of 4 Page 2 of 4 - DN-6724• 10/02/01 C mand, it activates its internal relay. The FCM supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM will discon- nect the supervision and connect the external power supply in the proper polarity across the load device. The discon- nection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The ex- ternal power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the control panel, so as to differentiate between a module and a sensor address. SPECIFICATIONS for FCM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 390 hA (LED flashing). External supply voltage (between Terminals T3 and T4): maximum 80 volts (RMS or DC). Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25' (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125' (53.975 mm) deep box. SPECIFICATIONS for FRM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25' (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125' (53.975 mm) deep box. RELAY CONTACT RATINGS for both FCM and FRM models Load Description Application Maximum urrent Voltage Rating C Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R = 5 ms) Coded 30 VDC 0.5 A Inductive (L/R = 2 ms) Coded 130 VDC 1.0 A Inductive (PF = 0.35) Non-Coded 1125 VAC 0.5 A PRODUCT LINE INFORMATION FCM-1 Intelligent Addressable Control Module. FRM-1 Intelligent Addressable Relay Module. A2143-20 Capacitor, required for Class A (Style Z) opera- tion of speakers. SMB500 Optional Surface-Mount Backbox. CB500 Control Module Barrier - required by UL for separating power-limited and non-power limited wiring in the same junction box as FCM-1. I MOUNTING DIAGRAMS Note CB500 Module Barrier, which creates isolated quadrant. ISOLATED QUADRANT n 4 The Face Plate Y WIRING DIAGRAMS The following wiring diagrams are provided: FCM-1: Typical notification appliance circuit configuration, NFPA Style Y. FCM-1: Typical fault-tolerant notification appliance circuit con- figuration, NFPA Style Z. FCM-1: Typical wiring for speaker supervision and switching, NFPA Style Y. FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. FIRMA: Relay module wiring diagram. V Fig. I FCM-1: Typical notification appliance circuit configuration, NFPA Style Y. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Communication Line 32 VDC max. Module polarities are shown in alarm. ,.... \ Refer to oanel documentation for TO Next type of cble required. FROM Panel Device or Previous CONTROL Device MODULE 24 VDC Circuit 47K EOL 0 DO NOT LOOP wire Resistor + 9 on terminals 3 & 4. / ELR-47K 8 - Break wire to provide (-) (-) 7 TENS 20 supervision of connections. (-) (+) 24 VDC 115 40 ONES LOOP ADDRESS POWER cs 0 o 9 SUPPLY (+) (+) Power Supply: - Isolated, regulated, UL listed EOL Relay TO NEXT control module or EOL Relay. power-limited per NFPA 70. shown ONE RELAY REQUIRED for each circuit, Listed for fire protection nrr1i7p?1 Some control panels have the RELAY BUILT IN . 24 VDC coil and do not require external wiring. 4 with battery backup. j A77-716B Refer to the NOTIFIER manual. V Fig. 2 FCM-1: Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Communication Line 32 VDC max. Module polarities are shown in alarm. \ Refer to panel documentation for TO Next CONTROL EOL Resistor is internal at MODULE terminals 8 & 9 0 \ on ilfl (-) (-) El. 7sws 2 3 4[El ONE S LOOP ADDRESS (+) (+) UL listed EOL Relay TO NEXT control module or EOL Relay. shown ff ONE RELAY REQUIRED for each circuit. energized Some control panels have the RELAY BUILT IN 24 VDC coil and do not require external wiring. A77-716B Refer to the NOTIFIER manual. t Lr24 e f cable required. (—) FROM Panel 7VDCCircuit or Previous Device OP wire 3 & 4. o provide supervision of connections. IIImy'IffVDC POWER SUPPLY Power Supply: Isolated, regulated, power-limited per NFPA 70. Listed for fire protection with battery backup. DN-6724 • 10/02/01 — Page 3 of 4 Page 4 of 4 — DN-6724 • 10/02/01 V Fig. 3 FCM-1: Typical wiring for speaker supervision and switching, NFPA Style Y. Refer to panel documentation • Connect modules to Listed compatible —) Communication Line for type of cable required. NOTIFIER control panels only. 10 Next (+) 32 VDC max. FROM Panel All wiring shown is supervised. Device (+) or Previous Wires must be supervised per NFPA. CONTROL Device Module polarities are shown in alarm. d MODULE Audio Circuit /DO NOT LOOP wire * on terminals 3 & 4. 47KEOL 8 Break wire to ensure of connections. supervision Resistor () () 7 TENS 2 ELR-47K 6 3 AUDIO AMPLIFIER ONES ± 70.7 VRMS max. LOOP ADDRESS 0 Use only models M-30, 9 M-100,orAA-120. (+) (+ U Amplifier must provide wiring supervision per NFPA. Speaker Switching Circuit: NFPA STYLE W TO Next 'Ki Control Module SUPERVISION Speakers must be listed for fire protection. Last module must return Refer to the Relay Contact Rating table for maximum load, wires for supervision. 6724wir3.wrnf V Fig. 4 FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised. - Communication Refer to panel documentation Line for type of cable required. Wires must be supervised per NFPA. TO Next 32 VDC max,(-) FROM Panel Module polarities are shown in alarm. Device (+) or Previous CONTROL Device EOL Resistor is internal at terminals 8 & 9. MODULE Audio Circuit Capacitors: A2143-20, 100 Bypass 16 V, non-polarized, < 10 pA leakage. / DO NOT LOOP wire on terminals 3 & 4. / Break wire to ensure supervision of connections. Supe AMPLIFIER ONES 70.7 VRMS max. LOOP ADDRESS 0 09 Use only models M-30, C" E AAA00,orMA20. (+) (+) - Amplifier must provide I I wiring supervision per NFPA. Speaker Switching Circuit: NFPA STYLE X TO Next Control Module J SUPERVISION Speakers must be listed for fire protection. Last module must return Refer to the Relay Contact Rating table for maximum load, wires for supervision. 6724wir4.wm! NOTES regarding AUDIO AMPLIFIER in Figures 3 & 4 above. Audio circuit wiring must be twisted-pair as a minimum. See NOTIFIER installation manual for detailed information. When a 70.7 V audio amplifier is used, terminals 1 and 2 are power-limited, while terminals 3 through 9 are non-power-limited. In this case, the CB500 barrier is required. Otherwise, all terminal wiring is power-limited. The CB500 includes a label indicating which terminals are non-power-limited. This label MUST BE PLACED adjacent to the nameplate label, which is on the module housing. TO Next Device *----------- RELAY 0 -6 oMoDULELEC) RELAY COMMON 2 09 0 NORMALLY CLOSED 2 8 4- i NORMALLY OPEN 20 7 - 2 RELAY COMMON 1 LTiI 6 — 3 NORMALLY CLOSED 1 19 15 -44- —4 NORMALLY OPEN 1 0 T OJ 4wirS.wf H FROM Panel or Previous Device Communication Line 32 VDC maximum. Refer to panel documentation for type of cable required. 4 Fig. 5 FRM-1: Relay module wiring diagram. Connect modules to Listed compatible NOTIFIER control panels only. Module does NOT supervise controlled circuits. FMM, FZM, and FDM Series Monitor Modules with FlashScan® Section: Intelligent/Addressable Devices California State Fire Marshal 7300-0028:202 LISTED CS669 S635 MARYLAND Stàte Fire Marshal 'VI EA Permit # 2020 143-.01-E (FDM-1) (except FDM-1) 457-99-E (FMM-1, Approved FMM-101, FZM-1) ' 0 =1 I1 6789 10 0 detail of FDM-1 \18 i 210 —note "ones" III"17 101514 2 addresses are 66 TENS 3 46 0, 2, 4, 6, 8 only T7. 2'' 4 ONES 0 I ILOOP ADDRESS 12, 2001 DN-6720• H-220 I(T)NOTIFIEW GENERAL Four different monitor modules are available for NOTIFIER in- telligent controls to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull sta- tions, or monitor and power a circuit of two-wire smoke de- tectors (FZM-1). FMM-1 - is a standard-sized module (typically mounts to a 4[101.6 mm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. FMM-101 - is a miniature monitor module (a mere 1.3" (33.02 mm) H x 2.75" (69.85 mm) W x 0.5" (12.70 mm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the FMM-101 to often be mounted in a single- gang box behind the device it's monitoring. FZM-1 - is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. FDM-1 - is a standard-sized dual monitor module used to monitor and supervise two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between ana- log intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FlashScan® is a registered trademark of NOTIFIER. FMM-1 MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address 01 - 159 (01 - 99 on tradi- tional systems). LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1 Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 can be used to replace MMX-1 mod- ules in existing systems. FMM-1 Applications - Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other no dry-contact alarm activation devices. May also be used to monitor normally- open supervisory devices with special supervisory indica-tion at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for su- pervision of the Style D circuit. Maximum IDC loop length is 2,500 ft./762 m (20 ohms maximum). This document is not intended to be used for installation purposes. We try to keep our I product information up-to-date and accurate. We cannot cover all specific applications or I IS09001 anticipate all requirements. All specifications are subject to change without notice. I For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 Kotilll •- N OTI Fl E fl 12 Clintonville Road, Northford, Connecticut 06472 ENllVEEfilNC & MANUFACTURING DN-6720 09/12/01 - Page 1 of 6 C C FMM-1 Operation - Each FMM-1 uses one of 159 avail- able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). FMM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 375 pA (LED flashing). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5' (114.3 mm) high x 4(101.6 mm) wide x 1.25 (31.75 mm) deep. Mounts to a 4' (101.6 mm) square x 2.125' (53.975 mm) deep box. FMM-101 MINI MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the AFC-600. Powered directly by two-wire FACP. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address (01-159). .- o Lu c o -I -J -J tjj o I The FMM-101 Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101 is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101 can be used to replace MMX-101 module in existing systems. FMM-1 01 Applications - Use to monitor a single de- vice or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally- open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the circuit. FIVIM-101 Operation - Each FMM-101 uses one of 159 available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type Page 2 of 6 - DN-6720 09/12/01 and the status (open/normal/short) of its Initiating Device Circuit (IDC). FMM-1 01 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (33.02 mm) high x 2.75" (69.85 mm) wide x 0.5' (12.70 mm) deep. Wire length: 6" (152.4 mm) minimum. FZM-1 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external powe source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address (01-159). LED flashes during normal operation (this is a program- mable option). LED latches steady to indicate alarm on command from control panel. The FZM-1 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional de- tectors back to the control panel. All two-wire detectors be- ing monitored must be UL compatible with the module. The FZM-1 has a panel-controlled LED indicator and can be used to replace MMX-2 modules in existing systems. FZM-1 Applications - Use the FZM-1 to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1 Operation - Each FZM-1 uses one of 159 avail- able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). FZM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 255 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VRMS maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25' (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125° (53.975 mm) deep box. 1 (", 1415 0 1 I ADDRESS I 0 2I 1 4 LOOP 2 31 3 5I . 1 8 76 7 TENS ONES I iL C FDM-1 DUAL MONITOR MODULE The FDM-1 Dual Monitor Module is intended for use in in- telligent, two-wire systems. It provides two independent two- wire initiating device circuits (IDCs) at two separate, consecu- tive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or normally closed security devices. The module has a single panel-controlled LED. NOTE: The FDM-1 provides two Class B (Style Y) IDC circuits ONLY. Class A (Style Z) IDC circuits are NOT supported in any application. FDM-1 Specifications Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 5.7 mA (LED on). Maximum operating current: 750 pA (LED flashi EOL resistance: 47K ohms. go Maximum IDC wiring resistance: 1,500 ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 2.125" (53.975 mm) deep. FDM-1 Automatic Addressing - The FDM-1 auto- matically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1 is set to address "56", then it will automatically assign itself to ad- dresses "56" and "57". NOTE: "ones" addresses on the FDM-1 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. INSTALLATION FMM-1, FDM-1, and FZM-1 modules mount directly to a stan- dard 4(101.6 mm) square, 2.125' (53.975 mm) deep, electri- cal box. They may also be mounted to the SMBSOO surface- mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to appli- cable local codes, ordinances, and regulations. These mod- ules are intended for power-limited wiring only. The FMM-101 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. PRODUCT LINE INFORMATION Mode! Description FMM-1 Monitor module. FMM-101 Monitor module, miniature. FZM-1 Monitor module, two-wire detectors FDM-1 Monitor module, dual, two independent Class B circuits. SMB500 Optional surface-mount backbox. ARCH ITECTS'/ENGI NEERS' SPECIFICATIONS Specifications of these and all NOTIFIER products are avail- able from NOTIFIER. ,&—CAViO1TY Avoid duplicating addresses on the system. II Face Plate for FMM-1, FZM-1, and FDM-1 MOUNTING DIAGRAMS for si'andard-sized modules 00 ON-6720 09/12/01 - Page 3 of 6 WIRING DIAGRAMS The following wiring diagrams are included: FDM-1 typical dual two-wire Style B initiating device circuit configuration. FMM.101, typical two-wire Style B initiating device circuit configuration. FMM-1, typical two-wire initiating circuit configuration, NFPA Style B. FMM-1, typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. FMM-1, typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). FZM-1, interface two-wire conventional detectors, NFPA Style B. FZM-1, interface two-wire conventional detectors, NFPA Style D. FIRMA, relay control module used to disconnect a power supply. Fig. I FDM-1: Typical dual two-wire Style B initiating device circuit configuration. Two Initiating Device Circuits (L&H) each power-limited to TO Next Device W FROM Panel 230 pA max. @ 12 VDC max. or Previous MONITOR (+) Device 47K EOL MODULE T32 mmunication Line Resistor ELR-47K ' ' VDC maximum. isted-pair is 98 10 Resistor : recommended. 47K EOL -9 6 All wiring shown is supervised 4I and power limited. ADDRESS Connect modules to listed compatible ELR-47K LOOP NOTIFIER control panels only. ANY NUMBER of UL Listed contact closure devices may be used. 6822w1r1.wmf 'DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. Install contact closure devices per manufacturer's installation instructions. TO 1110- NEXT DEVICE BLACK 14 RED I I UL LISTED I Compatible () () FMM-101 Control Panel 12 5 6789 10 56789 11 4/1 3 (00) 2 13 A- 10 1514 10 (t)(7) VIOLET10, 14 YELLOW 47K EOL INCLUDED . Fig. 2 FMM-101: Typical two-wire Style B initiating device circuit configuration. 6720w1r1 .wr,,f Page 4 of 6 - DN-6720 •09112/01 'ii i i 'J VIn,'JI T C11,7111111 i i V-Z Lill f W Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Install contact closure devices per manufacturers' installation instructions. Any number of UL-listed contact closure devices may be used. DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. V Fig. 3 FMM-1: Typical two-wire initiating device circuit configuration, NFPA Style B. 47K EOL Resistor ELR-471< TO Next Device MONITOR Initiating Device Circuit (IDC) MODULE NFPA Style B, power limited: 230 pA max. @ 12 VDC max. 97 ENS 29 115 4 14— Communication Loss ONES 'D, , ~ 10s (optional connection for panels which support this feature) FUTURE FEATURE 6720w1r2.wrnr -) FROM Panel or Previous —4 Device Communication Line 32 VDC maximum. Twisted-pair is recommended. V Fig. 4 FMM-1: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. EOL Resistor is internal at terminals 8 & 9 FROM Panel or Previous Device Communication Line 32 VDC maximum. Twisted-pair is recommended. --l1l-ab j5 Communication Loss ILOOP ONES ADD ESSr - (optional connection for panels which support this feature) FUTURE FEATURE U 67243.wf V Fig. 5 FMM-1: Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). (-) FROM Panel (+) or Previous Device fmmunication Line 32 VDC maximum. Twisted-pair is recommended. -111 4JI ±_-_._... Communication Loss ONES I LOOP ADDRESS (optional connection for panels çs0 which support this feature) FUTURE FEATURE U 672Swi,4.wmf Initiating Device Circuit (!DC) NFPA Style B, power limited: 230 pA max. @ 12 VDC max. 14K Series Resistor 47K EOL Resistor ELR-47K DN-6720- 09/12/01 — Page 5 of 6 Connect modules to listed compatible control panels only. WIRING______ S . Terminal wiring must be power limited. .1 DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. DO NOT LOOP wire under terminals. Break wire run to provide supervision of connections. THIS PAGE: Detectors must be UL listed compatible with module. Install detectors per manufacturers' installation instructions. Power to the interface module must be externally switched to reset the detectors. An FRM-1 relay control module can be used to switch power from a standard power supply; see Fig. 7 below. V Fig. 6 FZM-1: Interface two-wire conventional detectors, NFPA Style B. TO Next FROM Panel Device or Previous INTERFACE Device d MODULE Communication Line 32 VDC maximum. Twisted-pair is recommended. 3.9K EOL Listed Battery Backup Resistor (0 3 El - _____________________ 4 switched DC (included) ONES 4 power supply. A2143-1O LOOP ADDRESS 0 00 Ar— Optional Branch Circuit TO Next Interface Module 6720wr5 I Module supervises supply voltage and detector loop. V Fig. 7 FZM-1: Interface two-wire conventional detectors, NFPA Style D. 3.9K EOL Resistor (included) required at terminals 8 & 9 A2143-1O TO Next Device __________ INTERFACE h.._ d MODULEJ 0 Ng IllI7 TENS 2IF— I I I IUL1I "s" I I LOOP ONES 44- ADJ (C~ ~) 0 6720wir6.wmf U —) FROM Panel (+) or Previous Device Communication Line 32 VDC maximum. Twisted-pair is recommended. (—) Listed Battery Backup (+) switched DC power supply. A- Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. V Fig. 8 FRM-1: Relay control module used to disconnect a power supply. I TO Next Device DC POWER SUPPLY Listed for Fire (—) Protection with Battery Backup Page 6 of 6 - DN.6720 .09/12/01 RELAY CONTROL ci? MODULE E720wir7.wn,f L4 FROM Pane! +) or Previous - Device Communication Line 32 VDC maximum. Twisted-pair is recommended. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7300-0028:202 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 Fax (203) 484-7309 DESIGN: Models FMM-1, FMM-1 01, FZM-1, FSM-1 01, FDM-1 * monitor modules and Models FCM-1, FRM-1 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm 9 control units. *Rev. 05-02.01 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager June 9, 2000 DN-6726• H-240 N: IOTFIER® L' FIRE SYSTEMS GENERAL The NOTIFIER NBG-12LX is a state-of-the-&t, dual-ac- tion (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any NOTIFIER intelligent control panel. Because the NBG- 12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. FEATURES Maintenance personnel can open station without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTI- VATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Semi-flush, mounts to a standard single-gang (2.125" [5.3975 cm] minimum depth), double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Within ADA 5 lb. pull force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG.TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-1 2LX stations per loop on classic protocol systems (non-FlashScan). Up to 159 NBG-12LX stations per loop on FlashScan protocol systems. Dual-color LED blinks green for FlashScan systems. CONSTRUCTION Shell, door, and handle are molded of durable LE)(AN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word 'ACTIVATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; closing the door automati- cally resets the switch. NBG-12LX Addressable Manual Pull Station with FlashScan T11 Section: Intelligent/Addressable Devices U.S. PATENTS PENDING ® California State Fire Marshal 7150-0028:199 LISTED S692 <i Approved The NBG-12LX Addressable Manual Pull Station Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address set- tings (1-159 on FlashScan Systems, 1-99 on CLIP sys- tems). FlashScanTM is a trademark of NOTIFIER. LEXAN® is a regis- tered trademark of GE Plastics, a subsidiary of General Electric Company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 464-7161 FAX: (203) 484-7116 40 J N OTI Fl E fl 12 Clintonville Road, Northford, Connecticut 06472 ENGINEERING & MAIIFAC1URINC DN-6726 . 06/09/00 - Page 1 of 2 PRODUCT LINE INFORMATION Model Description NBG-12LX Dual-action addressable pull station. Includes key locking feature. SB-10 Surface backbox. BG-TR Optional trim ring. INSTALLATION The NBG-12LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the Model SB-10 sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG-TR) may be used. The BG-TR is usually needed for semi-flush mounting with 4' (10.16 cm) or double-gang boxes (not with single-gang boxes). ELECTRICAL SPECIFICATIONS Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 230 pA. ARCHITECTURAL/ ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN® (or polycar- bonate equivalent) with clearly visible operating instruc- tions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger. Stations shall be suitable for surface mounting on matching backbox SBA 0; or semi-flush mount- ing on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual sta- tions shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Detail of BREAKAWAY TAB* C 5 0 0 14 1 1302 . ....... . ......... ....... . 10 5 ~V8 7 O8 7 Terminal Connections 1 SLC (-) 2 SLC (+) Back of station without door. LED )TARY DECIMAL SWITCHES *Remove tab to select addresses above 99 (FlashScan systems only). Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Page 2 of 2 — DN-6726. 06/09/00 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 Page 1 of 1 CATEGORY: Manual Pull Stations/Boxes LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG- 12-LO, NBG-12L0B, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP, NBG-12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, *NBG12LPS NBG-12LPSP and NBG-12SP fire alarm pull boxes. The NBG-12 series is a dual action pull station that has normally open switch contacts. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. ,MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W and NBG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models NBG-LAOB and NBG-12LOB are intended for outdoor use when installed with Model WBB or WP-1 0 back box. *Rev. 10-01.2001 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. NA Date Issued: Authorized By OCTOBER 1, 2001 DIANE K. AREND, Senior Deputy Program Manager Listing Expires June 30, 2002 NOTIFIER® GENERAL An HVAC system supplies conditioned air to virtually every area of a building. Smoke introduced into this air duct system is thus distributed to the entire building. Smoke detectors for use in air duct systems sense the presence of smoke in the duct. The FSD-751 Pair duct smoke detector is a photoelectric detector, combining this detection technology with an efficient housing design that samples air passing through the duct, allowing detec- tion of a developing hazardous condition. When sufficient smoke is sensed, an alarm signal is initiated at the fire control panel monitoring the detector, and appropriate action can be taken to shut off fans and blowers and change over air handling sys- tems, etc. This can isolate toxic smoke and fire gases or prevent their distribution throughout the areas served by the duct system. Two LEDs on each detector can be programmed by the system control panel to provide a local alarm indication. A remote alarm output is provided for use with auxiliary devices. The FSD-751 P has remote test capability with the RTS451/RTS451 KEY Remote Test Station. Traditional panels support addresses of 0-99. The FlashScan® protocol supports addresses of 0-159. Patented FlashScan® is a new communication protocol developed by NOTIFIER Engi- neering that greatly enhances the speed of communication be- tween analog intelligent devices. Intelligent devices communi- cate in a grouped fashion. If one of the devices within the group has new information, the panel stops the group poll and concen- trates on single points. The net effect is response speed greater than five times that of earlier designs. APPLICATIONS Duct smoke detectors have specific limitations. Duct smoke detectors are: NOTa substitute for open area smoke detectors. NOTa substitute for early warning detection. NOTa replacement for a building's regular fire detection sys- tem. Call NOTIFIER for a copy of System Sensor's application guide, Proper Use of Smoke Detectors in Duct Applications, (A05-1004-00). INSTALLATION Wiring: For signal wiring (the wiring between detectors or from detectors to auxiliary devices), it is recommended that single conductor wire be no smaller than 18 AWG (0.75 mm2). The duct smoke detector terminals accommodate wire sizes up to 12 AWG (3.25 mm2). Flexible conduit is recommended for the last foot (30.48 cm) of conduit; solid conduit connections may be used if desired. Smoke detectors and alarm system control panels have specifi- cations for Signaling Line Circuit (SLC) wiring. Consult the con- trol panel specifications for wiring requirements before wiring the detector loop. The FSD-751 P/FSD-751 RP detector is de- signed for ease of wiring; the housing provides a terminal strip with clamping plates. LED Features: If programmed with the system control panel, two LEDs on each duct smoke detector light to provide June 5, 2001 DN-6821 • H-215 FSD-751 P and FSD-751 RP Intelligent Photoelectric Duct Smoke Detectors with FlashScan® Section: Intelligent Addressable Devices MEA 143-00-E (FSD-751P) 38900E Approved LISTED CS308 (FSD-751RP) (FSD-751PA, S1115 FSD-75IRPA) MARYLAND California State Fire Marshal State Fire Permit #2036 (FSD-751P) Marshal Permit #2060 (FSD-751RP) 3240-0028:205 local visible indication. Remote LED annunciator capability is avail- able as an option. Each duct smoke detector can only be wired to one remote accessory. NOTIFIER panels offer different feature sets across different panel models. As a result, certain features of the FSD-751 P/ FSD-751 RP may be available on some control panels, but not on others. Possible features, if supported by the control panel are: Panel controls the LED operation on sensor. Operational modes are: RED blink, RED continuous, GREEN blink, GREEN continu- ous, and OFF. SPECIFICATIONS FSD-751P Operating voltage range: 15to32VDC. Standby current: 300 pA @24 VDC (one communication every 5 seconds with LED blink enabled). Operating temperature range: 32° to 131°F (0° to 55°C). Humidity range: 10% to 93% (non-condensing). Duct air velocity: 500 to 4,000 feet/mm. (152.4 to 1219.2 meters! mm.). Dimensions: 14.375" (365.125 mm) wide x 5.500(13.970mm) high x 2.750" (69.850 mm) deep. Options: RTS-451, RTS-451 KEY, RA400Z. Separate auxiliary power not required. FSD.751 RP Operating voltage range: 15 to 32 VDC (comm. line voltage) and 24 VACNDC or 120/240 VAC auxiliary power* (separate source). *NOTE: The FSD-751RP requires a separate auxil- iary source. Standby current: 300 pA @24 VDC (one communication every 5 seconds with LED blink enabled). Auxiliary power current draw (@24 VDC): 26 mA (standby), 87 mA (alarm). Options: RTS-451, RTS-451 KEY, RA400Z, APA451. FlashScan® is a registered trademark of NOTIFIER. S This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover at specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 dl u N OTI Fl E 12 Clintonville Road, Northford, Connecticut 06472 ENGINEERING & MANUFACTURING DN-6821 06/05/01 - Page 1 of 2 Operating temperature range: 32° to 131°F (0° to 55°C). Humidity range: 10% to 93% (non-condensing). Duct air velocity: 500 to 4,000 feet/mm. (152.4 to 1219.2 meters/ mm.). Dimensions: 14.375° (365.125 mm) wide x 5.500(13.970mm) high x 2.750" (69.850 mm) deep. Relay contact ratings: 2 Form-C, DPDT, 10 A @250 VAC, 10 A @30 VDC (resistive). Minimum switching current of 100 mA @ 5VDC. Programming specifications/requirements for intelligent system control panels: The number of devices that can have their LEDs programmed to illuminate is limited by the features of the panel and the individual devices. The actual number of devices is determined by the control panel and its ability to supply LED current. Refer to the control panel installation manual for details. INLET TUBE SELECTION 6821in11.Ibt Outside Duct Width Inlet Tube* Up to 2 feet (0.6096 m) ST-1.5 2 to 4 feet (0.6096 to 1.2192 m) ST-3 4 to 8 feet (1.2192 to 2.4384 m) ST-5 8 to 12 feet (2.4384 to 3.6576 m) ST-10 *NOTE: Inlet tube is required and must be purchased separately. Order one inlet tube for each duct smoke detector ordered. PRODUCT LINE INFORMATION Model Description FSD-751 P Duct detector housing with FlashScan® photoelec- tric smoke detector. FSD-751RP Duct detector housing with FlashS can® photoelec- tric smoke detector, DPDT relay. ST-1.5 Metal sampling tube, duct widths Ito 2' (see table at left for metric lengths). ST-3 Metal sampling tube, duct widths 2' to 4'. ST-5 Metal sampling tube, duct widths 4' to 8'. ST-ID Metal sampling tube, duct widths 8' to 12'. RA400Z Remote annunciator alarm LED. RTS45I Remote test station. Mounts in single-gang box. Includes red alarm LED and magnet test switch. RTS45I KEY Key-activated remote test station. F36-09-00 Replacement filters. M02-04-00 Replacement test magnet. S08-39-01 Replacement photo insect screen. P48-55-00 Replacement end cap for plastic sampling tube. P48-21-00 Replacement end cap for metal sampling tube. A5053FS Replacement photoelectric sensor board. A5067 Replacement power board (without relay). A5060 Replacement power board (with relay). SAMPLE WIRING DIAGRAMS z N 0 C) FSD-751 P Detector Terminals See product Installation Intructions for wiring diagrams for the FSD-751RP + I 00 in Loop 2nd Detector Ak FSD-751P Duct Smoke Detector using a UL Listed control panel 682 lwi,2.wn,f FSD-751P Duct Smoke Detector with optional RA400Z The RA400Z COMMUNICATION LINE UL Listed Control Panel La N 0 T w'-0OO U 0 C.) 662 lwir3.wmf COMMON TEST \ Field-Installed \JUMPER RTS451/RTS451 KEY 4 FSD-751P Duct Smoke Detector with RTS45II RTS45I KEY NOTE: For RTS45I, Terminal 3 is not used. RTS45I does not have a Terminal 6. For RTS45IKEY, Ter- minals 3 and 6 are not used. The RTS45I --------------- The RTS45IKEY FSD-751 P Detector Terminals S Page 2 of 2 - DN-6821 • 06/05/01 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0028:205 Page 1 of 1 CATEGORY: Duct Smoke Detector Housing/Base LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 DESIGN: Models FSD-751 P and FSD-751 RP*duct smoke detectors. Unit consists of an enclosure, electrical components, sampling and exhaust tubes and listed photoelectric smoke detector sensor. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, air velocity rating and UL label. APPROVAL: Listed as a duct smoke detectors for use in HVAC systems having air velocities between 500 to 1191 4000 ft/mm. Suitable for use with separately listed compatible fire alarm control units. *Rev. 01-05-2001 1771 '., This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims This listing is not an endorsement or recommendation of the item listed This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2001 Listing Expires June 30, 2002 S Authorized By: BEN HO, Supervising Deputy Program Manager California State Fire Marshal 7150-1439:100 XAL-53. Pull Ring June 26, 1998 DNJ-5274• -450 S 'NOTIFIEW FIRE SYSTEMS XAL-53 Explosion-Proof Pull Station Section: Conventional Initiating Devices APPLICATIONS KILLARK® fire alarm stations are suitable for: Hazardous areas due to the presence of flammable L gases or vapors, combustible dusts or easily ignit- able fibers or flyings. E50498 Installation at petroleum refineries, chemical and pet- rochemical plants, storage areas, and other process- ing facilities where hazardous substances are handled and stored. (9 Areas where emergency control of fire alarm or sig- nal circuits is required. CE69 FEATURES Enclosure is made of copper-free aluminum alloy. CSA Conduit openings are 3/4" (19.05 mm) NPT feed- LR31085 through. Red, textured powder epoxy paint finish is standard on box and cover and provides high visibility for alarm station. Universal (1) normally open and (1) normally closed contact furnished standard. Bilingual nameplates included per CSA requirement. Internal ground screw is standard. Wiring range is #12 AWG through #24 AWG, solid or stranded. OPERATION 4-1/2(114.3mm) —2-1/4'-1 i— The alarm station is activated by lifting the front cover (5715) 1' and pulling down ring. This quick, easy-to-use two- (25.4) step process prevents unintentional operation. Op-erator is reset by depressing shaft and returning plate to original position. HAZARDOUS AREA (161.925) - CLASSIFICATIONS Class I, Divison 1 and 2, Group C and D. Class II, Division 1 and 2, Group E, F, and G. Class Ill, Hazardous Locations. NEMA 7CD,9EFG. XAL-53 3'(76.2 mi F(60.325) Dimensions T5-3/8' (136.525) (117.475) 11 5/16' dia. (7.9375 mm) (2 holes) AC DC - Make Break Continuous Make Continuous Volts Amperes VA Amperes VA Carrying Volts Break Carrying Amperes Amperes 120 60 7200 6.0 720 10 125 1.10 10 240 30 7200 3.0 720 10 250 0.55 10 480 1 15 172001 1.5 1 720 10 600 1 0.20 10 600 12 7200 1.2 720 10 CONTACT BLOCK RATING . KILLARK® is a registered trademark of Hubbell®. S This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTiFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 - At, N OTI F I E fl 12 Clintonville Road, Northford, Connecticut 06472 INCINEEllINC & MANUFACTURING DN-5274 • 06/26/98 - Page 1 of 2 OPERATIONAL DATA This enclosure is made of cast, copper-free aluminum al- loy. It is suitable for: Class I, Groups C and D; Class II, Groups E, F, and G; and Class Ill hazardous locations. All installations must comply with applicable local and/or Na- tional Electrical Code. /KOLA ONiY During installation, DO NOT use looped wire under ter- minals. Break wire run to provide supervision of con- nections. Like all electromechanical devices, these control stations require occasional maintenance. Parts may wear out or become defective due to adverse environmental conditions. See Maintenance Data below. CONTACT ARRANGEMENT NOT ACTIVATED POSITION MAINTENANCE DATA /AoTY Disconnect this device from the supplying circuit be- fore removing the cover. 1) To prevent corrosion, lubricant should be occasionally applied, as follows: Killark "LUBG" lubricant to box/cover flanges. Dow Corning Molykote 33 Grease, light consistency, to operator shaft. Keep all flanges clean and free of scratches. Some internal service parts are available. Consult the Killark factory for parts breakdowns. A C TI VA TED POSITION 1111. 3• •4 Page 2 of 2 - DN-5274 06/26/98 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7150-1439:100 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Killark Electric Mfg., 3940 Martin Luther King Dr, St. Louis, MO 63113 Contact: Thomas Michalski (314) 531-0460 DESIGN: Models XAL and XAS noncoded fire alarm boxes, followed by 1, 2, 3, 4, 5, 6, 13, 14, 41, 42, 43, 44, 45, or 46, followed by 1, 2, 3, 4, 5, 6, 7, or 8. Conduit sizes in 1/2", 3/4" and 1". Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 6A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control panels. Suitable for use in Class I, Group C and D, and Class II, Groups E, F, and G, and Class Ill hazardous locations. 03-23-95 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. is Date Issued JUNE 19, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager S S GENERAL The Pyrotector Model 30-3003 Explosion Proof Smoke De- tector is a sensitive yet rugged protection device that is de- signed for use in hazardous industrial and commercial loca- tions. The detector is designed to operate effectively with both slow smoldering and fast burning fires. FEATURES Rugged construction. Self checking and compensating circuitry maintains desired sensitivity. Heightened sensitivity triggered when smoke is increas- ing, but has not yet reached the preset sensitivity setting. Form A (SPST) N.C. contacts for connection to alarm output circuitry. SPST N.C. contacts for supervision of input power. 2.3% fixed sensitivity. APPLICATIONS Combustible storage facilities. Munitions manufacturing. Volatile chemical storage. Chemical processing plants. Petroleum refineries. Turbine enclosures. CONSTRUCTION & OPERATION The photoelectric smoke detector uses a solid-state infra- red-emitting diode (IRED) and a light-sensing photovoltaic cell arranged in a labyrinth assembly. The labyrinth permits free access to smoke but restricts external light. Because of its critical function to the operation of the detector, each IRED is selected with extreme care and is subjected to rigorous pre-production testing to ensure long-term reliability and per- formance. During normal operation (no smoke), the detector samples the air approximately every four seconds for a period of less than one millisecond. The photovoltaic smoke cell, which is placed at an angle to the pulsed invisible light source, is sensitive to the infrared light in the specified frequency emit- ted by the IRED light source and is designed to receive a signal only when the pulsed IRED source is activated. See Figure 1. When smoke enters the chamber, the light from the IRED reflects off the smoke particles and reaches the photovoltaic smoke cell. When the amount of light reflected by smoke reaches the factory-set threshold level, the smoke alarm cir- cuit is actuated. The detector will respond to a slow smoldering fire when smoke in the chamber reaches the preset sensitivity setting, typically 2.3%. July 20, 1992 DN-3846. 1-209 30-3003 Explosion-Proof Smoke Detector Section: Conventional Initiating Devices PHOTOVOLTAIC SENSOR CELL LCNS SMOKE CHAMBER Figure 1— Cross Section of Sensing Chamber Assembly If a fast-burning fire should occur, including fires inflammable liquids and other materials such as plastics that generate black smoke, the abnormally rapid movement of smoke into the detection chamber is sensed by a special rate-compen- sating circuit. An increase in smoke within the detection chamber that exceeds a preset rate causes the rate-com- pensation circuit to increase the intensity of the light source, which increases detector sensitivity. If the smoke continues to build at this rate, an amplifier circuit is triggered and the unit generates an alarm. If not, the detector reverts to nor- mal sensitivity. In normally smoky atmospheres, the detector will not go into alarm as long as the concentration is less than the fixed sen- sitivity of the detector. This results in a sensitive and posi- This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484.7118 i i •i N OTI Fl E R 12 Clintonville Road, Norlhford, Connecticut 06472 ENGINEERING &MRNIIFACTURIIVC DN-3846 . 07/20/92 - Page 1 of 2 S S S tive response with a very low potential for unwanted alarms. The main enclosure of the detector contains the electronic circuitry, alarm relay, and supervision relay. Fail-safe Operation. To ensure reliable operation, the Model 30-3003 is equipped with self-checking circuitry. A regulation photodiode, which is matched to the smoke de- tection circuit, continuously monitors the output intensity of the IRED and adjusts it as necessary to compensate for an accumulation of dust or other contaminants, or any other variation that can occur with temperature and time. A power supervision relay in the detector provides a trouble output signal in the event of an input power failure. The detector uses extensive filtering against RF and tran- sient interference. In addition, there is a two-second time delay before an alarm is generated. The printed circuit board inside the detector is coated to mini- mize the possibility of problems caused by moisture accu- mulation. Detector Outputs. The detector provides a set of Form A (SPST) N.O. contacts for connection to the alarm output circuitry and a set of SPST N.C. contacts for supervision of input power. The alarm output latches on in the event of an alarm and an LED located on the outer surface of the hous- ing is illuminated to provide a visual indication that an alarm condition has occurred. The detector is reset by momen- tarily interrupting input power. Classification. The Model 30-3003 is designed to meet NEC requirements for Class I, Groups C and D; Class II, GroupsE, F, and G; and Class Ill hazardous areas. Explosion-Proof Certification. The Model 30-3003 is certified by the German Electric Industry Association, VIDE, to meet Standards 0171/ "Special Protection" (Ex)sG5 (sand encapsulated), and PTBICENELEC approved as EEx q II T5. SPECIFICATIONS Operating voltage: 20 to 28 volts DC. Operating current: Standby: 10 milliamperes. Alarm: 35 milliamperes. Temperature range: —4°F to +140°F (-20°C to +60°C). Maximum air velocity: 3960 feet per minute. Relay contact rating: 2 amperes at 30 VDC, 0.5 ampere at 125 VAC. Dimensions: Diameter: 5-5/16". Depth: 3-1/2". INSTALLATION The Model 30-3003 is intended for surface mounting. The mounting screw holes are counterbored for No. 8 flat-head screws. Six pigtail wires are brought through a strain relief and compound sealed within an aluminum adapter. A close nipple is furnished to permit coupling of the detector assem- bly to the furnished junction box. All connections between the pigtail wires and external system wiring are contained within the junction box. DETECTOR LOCATION The smoke detector is normally mounted on the ceiling not less than six inches from a side wall. The exact location Of the detector must be determined by an evaluation based on engineering judgment supplemented, if possible, by field tests. For additional information on detector location and spacing, contact the National Fire Protection Association, Battery- march Park, Quincy, Massachusetts 02269, and request a copy of NFPA Number 72E, the Standard on Automatic Fire Detectors. DETECTOR CONNECTIONS The Model 30-3003 contains two sets of relay contacts One set of N.O. Alarm contacts (violet) close upon detec- tion of smoke. One set of N.C. Trouble contacts (yellow) close when the detector is powered. Power is applied to the detector at the red (positive) and black (negative) pigtails. MAINTENANCE Regularly scheduled maintenance is normally not needed, however, periodic cleaning of the smoke chamber may be necessary when detectors are located in abnormally dirty or dusty environments. Vacuuming around the smoke cham- ber housing prior to blowing out the chamber with a "dry air" hose is recommended. NOTE: The Mode! 30-3003 is NOT designed to be serviced or repaired in the field. Disassembly of the detector in the field will VOID both the explosion-proof rating and the warranty. If service or repairs are required, RETURN THE ENTIRE UNIT TO THE FACTORY The smoke detector can be tested using the same methods employed for any photoelectric detector. DO NOT USE canned aerosol smoke devices to test the de- tector, since damage can result. ENGINEERING SPECIFICATIONS The detector shall be a 2.3% fixed sensitivity photoelectric smoke detector, providing minimum response time to all fire types. The detection chamber shall extend beyond the main hous- ing into the area to be protected, to provide maximum smoke entry capability into the chamber from any direction. The detector light source shall be an IRED (Infrared Emitting Diode). Typical detector current consumption in the standby condition shall be 10 milliamperes. The detector shall lock in on alarm and have a visible alarm indicator LED. The detector shall have SPST alarm relay contacts for con- nection to the fire alarm control panel and also power super- vision contacts. The detector enclosure shall be an explosion-proof flanged housing designed to meet NEC classifications of: Class I, Groups C and D. Class II, Groups E, F, and G. Class III hazardous areas. The detector shall be intended for surface mounting and con- nection to the system wiring shall be by means of pigtails in a rated enclosure (furnished). PRODUCT LINE INFORMATION 30-3003 Explosion-Proof Smoke Detector. Page 2 of 2 - DN-3846 •07/20/92 006 12/16/98 WED 11:14 FAX 916128298750 DET TRONICS - Federal Physio-Technical Institute Conformance Certificate PTB No. Ex 83/2031 X This certificate applies to the following production items Fire Smoke Detector Types 130/1,2,3,4,5,6 and Infrared Flame Detector Types 81111,2,3,4,5,6 and Thermo Differential Detector Types 215/1,2,3,4,5,6 and Thermo Mamum Detector Types 21611,2,3,4,5,6 Manufactured by: Hekatron (Limited Liability Company) Address: D-7811 SulzburgfBaden The design of these electrical production items, together with the different allowable ways to assemble them are defined in the Supplement to this Certificate of Conformance. The Federal Physio-Technical Institute certifies as board of exirers, according to Article 14 of the Guidelines by the Council of European Communities, dated December 18, 1975 (76/117/EWG), the conformity of the above production items with the attuned European norms Electrical Production Items for Explosion-Endangered Areas EN 50 014-1977 / VDE 0171 Part 113.78 General Determinations EN 50 017-1977 / VDE 0171 Part 4/5.78 Sand Incasing q" after the production items successfully passed a method of construction tests. The results of these tests are documented in a confidential test reDort. The production item is to be marked as follows: EExqUT5 The manufacturer shall be responsible for the method of construction of any. production item so marked to correspond with the test material attached to this Certificate as Supplement and that the prescribed assembly tests were successfully passed. Pursuant to Appendix II to the Guidelines of the Council, dated February 6, 1979 (79/196/EWG) the electrical production item may herewith be marked with the joint mark of distinction as shown hereon. By order of Braunschweig March 14, 1983 (Signed & Sealed) (City) Director-Engineer Schebsdat Sr. Administrative Adviser - S - Test Certificates without signature and without ocia1 seal are riot valid. Certificates for distribution may not be altered. Extracts or changes require the permission of the Federal Phy -Technical Iriatute, Bundesafle 100, P.O. Box 3345, D-3300 Braunschweig. Series PS-12/24-8 Power Supply - Series PS-12/24-8 (Batteries Not Included) Input and output synchronization (including pass through) FACP NAC supervision steered to either input #lor#2 Common input and output trouble circuit Input and output LED indicators AC fail supervision (Form "C" contacts rated @ 1 amp@24 VDC or1I5VAC Battery presence and low battery supervision (Form "C" contacts rated @ 1 amp @ 24 VDC or 115 VAC Ground fault detection Thermal and short circuit protection with auto reset Built-in battery charger for sealed lead acid or gel type batteries Automatic switch over to stand-by batteries when AC fails Zero voltage drop when switching to battery stand-by Circuit breaker battery protection Unit includes power supply, red enclosure, cam lock, open frame transformer and battery leads "Size: 15.5" H x 12.5" W x 4.5" D wf.clock AuA U1 :11 MEA Fire Alarm Systems Helping People Take Action TM POWERPATH TM Desc4otion POWERPATH Series PS-1 2/24-8 is a power limited 8 ampere power supply/charger used to expand the supervised power capability of a Fire Alarm Control Panel (FACP) for Notification Appliance Circuits (NAC) as well as providing auxiliary power to support system accessories. Power Limited refers to the ratings of the output circuits per UL 864 and NFPA 70 (NEC), Article 760. Two (2) Class "A" or Class "B" inputs from an FACP and two (2) dry trigger inputs are provided to direct and deliver regulated and filtered 12 or 24 VDC via four (4) Class "B", two (2) Class "A" or two (2) Class "B" and one (1) Class "A" NAC Circuits. Each Class "A" or Class "B" ouput has a maximum rating or two (2) amperes. A single output of four (4) amperes can be achieved by paralleling two (2) Class "B" outputs. POWERPATH Series PS-1 2/24-8 is compatible with all Wheelock's conventional 12 or 24 VDC Life Safety Notification Appliances and with its Patented BUILT-IN SYNCHRONIZED MODE feature, it can control and operate all of Wheelock's Synchronized Notification Appliances. Additionally, the horn may be silenced while is maintaining strobe activation. Features Approvals (PS-I2I24-8):UL 864, MEA, CSFM NFPA-72 COMPLIANT Compatible with 12 or 24 VDC FACP 115 VAC @ 60Hz and 3.2 amps input voltage 8 amperes rated supply current @ 12 or 24 VDC Filtered and regulated power supply outputs Field selectable 12 or 24 VDC outputs Each Class "A" or Class "B" output has a maximum rating of two (2) amperes. 50 mA of resettable (internal or remote) auxiliary power Accepts 2 Class "A" or 2 Class "B" NAC circuit inputs Additional activation options are: NC contacts or open collector of a transistor Programmable EOL Resistor Supervised NAC Circuit Outputs (4 Class "B" or 2 Class "A" or 1 Class "A" and 2 Class B") with a maximum 2 amperes per circuit Class 2 rated power limited outputs 2 Class "B" Outputs may be paralleled for more power on a circuit (Total 4 Amperes on the circuit) 2 Outputs may be paralleled for more power on a circuit (total of 4 amperes on the circuit) S . Dip switch selectable options Code 3 (Temporal) option Steady output option Built-in Synchronization Mode Copyright 2001 W/iee/ock, Inc. All r,bIs reserved. D ii'i°1 !! iiiiTii!' ! S REAR Lii.i 1_• FAULT RESET _*RU?s?SR FAULT UR OFF ON ocr+ 0E OFE U OUT rrT1n I rirr1n pRim L LL 2EOL Return To FACP From From or next s;gnaling From From NAC 2 NA NAC I NAC 2 NAC1?C2 device 2.2K EOL OPliOflEl paralleled CIUSEB TAIpEI Figure 1 Class BTConnections Figure 2 Class "A"Connections POWERPATH TM Applications The following applications illustrate the use of synchronized appliances powered by POWERPATH. POWERPATH can QEIIY be used on NAC's with continuously applied voltage. Do not use POWERPATH on coded or interrupted NAC's in which the applied voltage is cycled on and off. POWERPATH can synchronize the Series RSS, RSSP Strobes, the Series NS!NS4! NH and AS/AH horn strobes and the Series SL strobes. Note: The Series RSS and SL strobes are also part of other products (e.g. speakers, chimes, multitone, etc.). Each output of POWERPATH can be a Sync Circuit to drive audible/ visual, visual, audible or synchronized appliances. Refer to audible and visual notification appliance Data Sheets or Installation Instruction Sheets for additional information. EO LR Basic Line Diagram C Architects and Engineers Specifications The power supply shall be Wheelock POWERPATH Series PS-2/24-8, or equivalent. The unit shall be a stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC). The unit shall be UL 864 approved for power limited operation of its outputs and comply with NFPA 70 (NEC), article 760. The power supply shall be listed under UL Standard 864, and have MEA and CSFM approvals. The power supply shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a "Dry contact" closure. The unit shall be an 8 ampere, 12 or 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 9 to 30 VDC. The primary application of the unit shall be to expand a fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories. The power supply shall provide four Class "B', two Class "A", or two Class 'B" and one Class "A' NAC circuit(s). The unit shall also supply resettable auxiliary power of not less than 50 mA at 24 VDC. The power supply shall be capable of charger batteries of up to 12 ampere hours per NFPA 72 (1999). Input activation shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 2 amperes and shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The unit shall have the capability of achieving a four ampere NAC circuit output simply by paralleling two of the NAC circuit outputs. The power supply shall provide independent loop supervision for either Class 'A" or Class "B" FACP MAC circuits and shall have the capability to 'steer" all alarm or trouble conditions to either incoming NAC circuit. The unit shall have common output terminals and common trouble input terminals. The power supply shall be powered from a 115 VAC, 60 Hz source with a current consumption of 3.2 amperes. The unit shall incorporate short circuit protection with auto reset. The power supply shall incorporate a built-in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure. The charger shall incorporate circuit breaker protection for the batteries and have the ability to report low battery and/or no battery condition(s). Stand by current for battery back up shall be 75 mA. The cabinet dimensions shall be 15.5" H x 12.5" W x 4.5" D. A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARININGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Specifications and Ordering Information Model Number Order Code Input Voltage/Current PS-12/24-8 8114 115 VAC, 60 Hz; 3.2 amps PS-12/24-8E (Note: no agency approvals) 8218 220 VAC Output NAC Circuits Output Voltage/Current Four (4) Class "B" 12/24 VDC @2 amps per Circuit Two (2) Class "A" or 8 amps maximum available One (1) Class "A" and Two (2) Class "B" Standby Current 75 mA Maximum Loop Resistance 100 Ohms Standby Batteries Standby Time Alarm Output Total ijtes Aux Output Current VDC 112 AH (uses two (2)12 VDC batteries in series) Amps / 24 24 Hours 8 Amps/15 Minutes 50 mA 60 Hours 8 Amps / 15 Minutes 12 VDC / 12 AH 24 Hours 8 Amps /15 Minutes 50 mA 60 Hours 8 Amps / 15 Minutes 24 VDC / 7 AH (uses two (2)12 VDC batteries in series) 24 Hours 8 Amps / 15 Minutes 12 VDC / 7AH 24 Hours 8 Amps/15 Minutes NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION National Sales Office 800-631-2148 Canada 800-397-5777 E-Mail: info@wheeiockinc.com http://www.wheelockinc.com 3 YEAR WARRANTY Made in USA A1021A Distributed By: 273 Branchport Avenue' Long Branch, NJ 07740 0 TEL: 732-222-6880 0 FAX: 732-222-2588 3101 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING .BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0785:149 Page 1 of CATEGORY: Power Units USTEE: Wheelock Inc., 273 Branchport Ave., Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 DESIGN: Model P5-12/24-fl Indicating Circuit Power Supply. Unit is a regulated 12 or 24 VDC power supply/charger used for supervision and expanded power driving capability of up to four notification appliance circuits. The unit is intended for use with Altronie's Model E0L22 end-of-line risistor pacicage. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC input, 120124 VOC output, INSTALLATION: In accordance with listee's printed Installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power supply unit for use with separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation - NOTE: For fire alarm use, the Standby batteries must provide at least 24 hours standby power during power loss. The battery circuit must be fully supervised. XLF: 7315.1335:107 08-so-ge This listing is based upon tech nical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results andlor other data but does not make an independent verification of any claims. This listing Is not an endorsement or recommendation of the item listed. This hating should not be used to verify correct operational requirements or installation "-----" criteria. Refer to isles's data sheet, installation instructions andfor other suitable information sources. Dale Issued: APRIL 16, 2001 Listing Expires June 30, 2002 A uthojized By. BEN HC. Supervising Deputy Program Manager S S UL MEA 10 IRE ALARM SYSTEMS Helping P eople Thk A ctioa SPEC 1 FIRE hInuThj t f, lakt SERIES AS SINGLE & MULTI-CANDELA AUDIBLE STROBE APPLIANCES SERIES AH AUDIBLES Description Wheelock's patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with less current draw and Zero Inrush. I Strobe options for wall mount models include 15175cd or Wheelock's patented Multi-Candela strobe with field selectable candela settings of: 15, 30, 75 or 110cd. Ceiling mount models are available in 15, 30, 75 or 100cd intensities. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. Additionally, the audible may be silenced while maintaining strobe activation. All models may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules or the PS-12124-8 Power Supply with Wheelock's Patented Sync Protocol. Synchronization of the continuous horn tone provides the temporal (Code 3) tone as mandated by NFPA-72 (1999) for all audible appliances. This ensures a distinct temporal (Code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized, the temporal sound may overlap and not be distinctive. At the same time, the strobes will also be synchronized. This provides the ability to comply with ADA recommendations concerning photosensitive epilepsy and NFPA and UFC standards when installing two or more visual appliances within the field of view. All of this, plus the ability to silence the audible is achieved by using only 2 WIRES. For Weatherproof Series AS, See Datasheet S9004 Copyright 2002 Wheelock Inc. All rights reserved. SERIES AS SERIES AH F o P 11 Multi-Candela Indicator (bottom of lens) Features Approvals include: UL 1971, UL 464, California State Fire Marshall (CSFM), New York City (MEA), Factory Mutual (FM), Chicago (BFP). ADNNFPAIUFC/ANSI Compliant. Wall mount models are available with Field Selectable Candela Settings of 15, 30, 75 or ll0cd (Multi-Candela models) or 15/75cd. Ceiling mount models are available in 15, 30, 75 or 100cd. Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones. Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate. Strobes produce I flash per second over the regulated voltage range. 12 and 24 VDC models with wide New UL 'Regulated Voltage" using filtered DC or unfiltered VRMS input voltage. Wall Mount or Ceiling Mount models. Synchronize with Wheelock SM, DSM or PS-12124-8 Power Supply with Wheelock's built-in sync protocol. ZERO Inrush above Peak. Compatible with all Wheelock 2-Wire products. Fast installation with IN I OUT screw terminals using #12 to #18 AWG wires. #SM Sync Module is rated for 3.0 amperes 88 24 VDC. #4DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions (P83123 for SM nd P83177 for DSM). ###Refer to Data Sheet S9001 or Installation Instructions P83862 for PS-12/24-8 Power Supply. sywc MODULES / POWER SUPPLY Input Average Model Number Order Voltage Current Mounting Code voc (AMPS) © Options 24 VDC SM-12/24-R' 6369 24 .025 W DSM-12/24-R" 6374 24 .038 W PS-32/24-8 °'° 8314 120 VAC Table 5: dBA Ratings for 12 VDC and 24 VDC Series AS/AH 12 and 24 VDC Audible Description Volume Reverberant dBA Per UL 464 88 10 ft. Anechoic dBA © 10 ft. Continuous Horn High 91 99 Medium 88 95 Low 83 90 Code 3 Horn High 87 99 Medium 84 95 Low 79 90 Table 6: Average Current (AMPS) for Ceiling Mount 24 V Audible Strobe At the 3 Audible Settings © 16, 24, and 33 VDC dBA Levels Models Voltage 16.0 VDC 24.0 VDC 33.0 VDC Average Current with High dBA Setting (99 dBA) As-2415c .130 .106 .102 AS-2430C .178 .135 .131 AS-2475C .357 .248 .200 A5-24100C .404 .277 .245 Average current with Medium dBA Setting (95 dBA) AS-2415C .116 .091 .079 AS-2430C .164 .120 .103 AS-2475C .339 .226 .179 AS-24100C .389 .258 1 .217 Average Current with Low dBA Setting (90 dBA) AS-2415C .112 .082 .069 AS-24300 .160 .133 .095 AS-2475c .332 .219 .164 AS-24100C .382 .252 .207 Table 7: Average Current • (AMPS) for Wall 35175 ed 12 V Audible Strobe At the 3 Audible Settings 158, 12, & 17.5 Voltage dBA Level Model - 8.OVOC 12.SVOC 17.SVDC Averge Current with High dBA AS-121575W .408 .256 .251 (99 dBA) Average Current with Medium As-121575w .354 .217 .182 dBA (95 dBA( Average Current t62 with Low d8A AS-121575W .348 .194 (90 dBA( * Average Current per actual Wheelock Production Testing at listed VDC. For Rated Average and Peak current across UL Regulated Voltage Range for both Filtered DC and Unfiltered VRMS, see Installation Instructions. 0* Refer to Data Sheet S7000 for Mounting Options. NOTE: All CAUTIONS and WARNINGS are identified by the symbol.. All warnings are printed in bold capital letters. .A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at I flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of ito 2 flashes per second and ADA Guidelines specify a flash rate of Ito 3 flashes per second. o All candela ratings represent minimum effective Strobe intensity based on UL 1971. Series AS Strobe products are listed under UL 1971 for indoor use with a temperature range of 320 F to 1200 F (0° C to 490 C) and maximum humidity of 93% (± 2%). Series AH-24 horns are listed under UL 464 for audible signal appliances (Indoor use only). Series AH-24WP audible appliances are listed under UL 464 for indoor/outdoor use with a temperature range of -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95%. "Regulated Voltage Range" is the newest terminology used by UL to identifythe voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Input Voltage VDC Regulated Voltage Strobe Range VDC/FWR Candela (cd) AS-24MCW-FR 24 16.0 330 15/30/75/110 AS-241575W-FR 24 16.0-33.0 15 (75 on Axis) AS-121575W-FR 12 8.0-17.5 15 (75 on Axis) AS-2415c-FW 24 16.0-33.0 15 AS-2430C.FW 24 16.0- 33.0 30 As-2475c-Fw 24 16.0 - 33.0 75 AS-24100C-FW 24 16.0-33.0 100 ASWP-2475W-FR 24 16.0-33.0 7588-31°F Table 2: Average Current °(AMPS) i'orAS-24 Mc Wall Models @ Each Candela Setting Average Cunentwfth High dBA Setting (99 dBA) 15od 30od 75cd 110cd S Voltage 16.0 VDC .935 .142 .242 .308 24.0 VDC .088 .120 .174 .224 33-0 VDC .099 .120 .152 .190 Average Current-with Medium dBA Setting (95 dB 16.0 VDC j .081. .128 J .225 [ .296 24.0 VDC .088 .105 .157 .207 33.0 VDC .068 .093 .119 .157 Average Ctrtent.wtth Low dBA Setting (90 dBA) 16.0 VDC .077 .119 .222 .294 24.0 VDC .060 .( .142 .200 33.0 VDC .055 .081 .109 .147 Table 3: Average Current * (AMPS) Series AH-24-R/W & WP (Horn Only) VOLTAGE High Medium Low 16.0 VDC .033 .019 .013 24.0 voc .039 .023 .016 33.0 VDC .050 .028 .020 Table 4: Average Current ° (AMPS) Series AS-241575 VOLTAGE High Medium Low 16.0 VDC .124 .108 .103 24.0 VDC .102 .083 .077 33.0 VDC .100 .077 .067 DSM STROBE NAC CIRCUIT + SYNC - OUT -0+ IN 1 JI MINUS I AUDIt MINUS 2 0 * IN 2 STROBE NAC 0 * OUT 2 CIRCUIT RETURN SERIES AS APPLIANCES SYNCHRONIZED W/ MULTIPLE DSM MODULES DSM Interconnecting wiring Shown. Maximum of twenty (20) DSM #1 A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83947) SERIES AS-24MCW, (P84023 AND P84024) SERIES AS SINGLE CANDELA, (P83519) Seies AH, (P83641) Series AH-WP AND 'GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL EFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR 'REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. THESE APPLIANCES ARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wirina Diaarams' SERIES AS APPLIANCES SYNCHRONIZED W/ DSM MODULE CLASS"A" NAC CIRCUIT W/ NO AUDIBLE SILENCE FEATURE SERIES AS APPLIANCES NON-SYNCHRONIZED FROM TO NEXT + APPLIANCE APPLIANCE - OR EOLR OR FACP PRECEDING SERIES AS APPLIANCES SYNCHRONIZED W/ SM MODULE CLASS "B" NAC CIRCUIT W/ AUDIBLESILENCE FEATURE SM STROBE Strobe A NAC -0- STROBE Circuit 4A,,1,ble AS AS Audible EOLR Audible NAC Circuit SERIES AS & RSS APPLIANCES SYNCHRONIZED W/ P5-12-24-8 OUTPUTS EOLR 1.4 4-CLASS A OR AS RSS 2-CLASS H AS RSS S-12124-8 _ So.ie P # For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions (P83123 for SM and P83177 for DSM). Forwiring information on the PS-12/24-8 Power Supply refer to Installation Instructions P83862. S Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible Strobe shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). The audible/strobe shall be listed for indoor use and both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design and shall have Zero Inrush. Where wall mount, Multi-Candela appliances are specified, the strobe intensity shall have a minimum of four (4) field selectable settings and shall berated per UL 1971 for: 15, 30, 75 or 110 candela. The selector switch for selecting the candela shall be tamper resistant and not accessible from the front of the appliance. The 15/75 candela strobe shall be specified when 15 candela UL 1971 listing with 75 candela on-axis is required (e.g. ADA compliance). For ceiling mount applications, the strobe intensity shall be 15, 30, 75 or 100 candela. When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-1 2/24-8 Power Supply with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. - Specifications and Ordering Information Model Order code Strobe Candela Non-Sync Sync w/SM, DSM or PS-12124-8 24 VDC 12 VDC Wall Mount ceiling Mount Mounting Options AS-24MCW-FR 9024 15/30175/110 X X X X A,B,D,E,F,G,H,J,O,R,S,X AS-24MCW.FW 9025 15/30175/110 X X X x A,B,D,E,F,G,H,J,O,R,S,X AS-241575W-FR 7405 15 (75 on Axis) X X X A,B,D,E,F,G,H,J,O,R,S,X AS-121575W-FR 7410 15 (75 on Axis) X X X X A,B,D,E,F,G,H,J,O,R,S,X AS-2415C-FW 7411 15 X X X X A,B,D,E,F,G,H,J,O,R,S,X AS-2430C-FW 7412 30 X X X X A,B,D,E,F,G,H,J,O,R,S,X AS-2475C-FW 7413 75 X X X - - X A,B,D,E,F,G,H,J,O,R,S,X A5-24100C-FW 7414 100 X x X X A,B,D,E,F,G,H,J,O,R,S,X ASWP-2475W-FR** 9012 75 @ -31°F X X X - X I (see Data Sheet S9004) AH-24.R 7892 X X X X X A,B,D,E,F,G,H,J,O,R,S,X AH.12-R 7891 X X X X X A,B,D,E,F,G,H,J,O,R,S,X AH24WP.R** 7416 X X X - X X K AH-I2WP-R°° 7415 X X X X X K *Refer to Data Sheet S7000 for Mounting Options. **For Weatherproof Series AS/AH specifications see data sheet S9004. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 E-mail: lnfo@wheelockinc.com http://www.wheelockinc.com 3 YEAR WARRANTY Made in USA Distributed By: S Ai,c4r1 WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588 S8100 01102 S CALIFORNIADEPARTMENT OF FORESTRY & FIRE PROTECTION . OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125.0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired USTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-8707 DESIGN: Models AS-1215, -2415,-1230,-2430,-121575,-241575, .2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and - 24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-241 SC, -2430C, -2475C and -241000 audible/strobes for the hearing impaired followed by two alphaFnumeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, .24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW audibleistrobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP.2575W is also suitable for outdoor use. RATING: Electrical 8-17.5/16.33 VDCIVFR AH-12, AH-12WP: 10.5-15.6 VDC, AH-24: AI-l-24WP:18-31 VOC Candela 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 100:100cd, 110:11ocd AS-24MCW: Selectable 1 5cd, 30cd, 75cd, llOcd Rev. 06.04-01 0 Listing No. 7125-0785:131 Page 2 of 2 INSTALLATION; In accordance with listee's printed installation instructions, applicable codes and ordinances and Ina manner acceptable to the authority having jurisdiction. *Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -Ware for wall mount only. Models with suffix -C are for ceiling mount only. MARKING: Listees name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units, For indoor use only except Models AH-1 2WP and AFI-24WP audible appliances are suitable for indoor/outdoor. For. synchronization, Models AS Series must be used with Model SM-12/24, SMX-1 2/24, DSM-1 2124 or IDSMX-1 2/24 sync control module (CSFM Listing No. 7300- 0785:132). These appliances can produce a distinctive three pulse Temporal Pattern fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1998 edition. NOTE: Models ASWP-2475W, AH.12, AH-24, .12WP and -24WP audible devices are not suitable for the hearing impaired applications. Rev. 06-04.01 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2001 Listing Expires Juno 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager utllJc r (91. MEAL *Fire Alarm Systems ()( V i \r Helping People Take Action TM pv SPEC I rLL\J!MM1 M A Family of Multi-Candela AppliancesSM SERIES RSS & RSSP SINGLE & MULTI-CANDELA STROBES & STROBE PLATES S S DESCRIPTION Wheelock's patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw and Zero Inrush while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 15/75 and 185cd or Wheelock's patented Multi-Candela strobe with field selectable candela settings of: 15, 30, 75, or llOcd. Ceiling Mount models are available in 15, 30, 75, 100, 150, and 177cd intensities. All models may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules or the PS-12/24-8 Power Supply with Wheelock's Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72 (1999). Wheelock's Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with Wheelock's SBL2 surface backbox. For Weatherproof Series RSS See Datatsheet S9004 Copyright 2001 Wheelock, Inc. All rights reserved. L Multi-Candela Indicator (bottom of Strobe Lens) Features Approvals include: UL 1971, New York City (MEA), California State Fire Marshall (CSFM), Factory Mutual, Chicago (BFP). High Candela Approvals: UL1971. Pending: MEA, Factory Mutual, BFP, and CSFM. ADNNFPNUFC/ANSI compliant. Meets OSHA 29 Part 1910.165. Wall mount models are available with Field Selectable Candela Settings of 15, 30, 75 or 110 cd. (Multi-Candela models) or 15/75, and185 cd. Ceiling mount models are available in 15, 30, 75 100, 150 and 177 cd. Low current draw with temperature compensation to reduce power consumption and wiring costs. Strobes produce 1 flash per second over the regulated voltage range. 12 and 24 VDC models with wide New UL 'Regulated Voltage" using filtered (DC) or unfiltered VRMS input voltage. Wall Mount or Ceiling Mount models. Synchronize with Wheelock SM, DSM or PS-12/24-8 Power Supply with Wheelock's built-in sync protocol. ZERO Inrush above Peak. Compatible with all Wheelock 2-Wire products. Fast installation with IN/OUT screw terminals using #12 to #18AWG wire. .NOTE: All CAUTIONS and WARNINGS are identified by the symboj . All warnings are printed in bold capital letters. AblVARNlNG: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFO R E U S I N G SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR W A R N I N G S C O U L D R E S U L T I N IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COU L D R E S U L T I N PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) s p e c i f i e s a f l a s h rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL 1971. Series RSS & RSSP Strobe products are listed under UL 1971 for indoor use with a temperature range of 320 F to 1200 F (00 C to 490 C) and maximum humidity of 93% (± 2%). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this ch a n g e , UL used the terminology "Listed Voltage Range". Table I: Specifications & Ordering Information - Multi-Candela and Single Candela Models - WALL MOUNT Model Order Code Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (CD) Average Current * @ 24 VDC 15cd 30cd 75cd llOcd Mounting Options 0* RSS-24MCW-FR 9400 24 16.0-33.0 15/30/75/110 .050 .081 .133 .161 B,D,E,F,G,H,J,N,O,R,X RSS.24MCW-FW 9401 24 16.0-33.0 15/30/75/110 .050 .081 .133 .161 - B,D,E,F,H,J,N,O,R,X RSS-241 575W-FR 7471 24 16.0-33.0 15 (75 on Axis) .065 B.D,E,F,G,HJ,N,O,R,X RSS-121575W-FR 7476 12 8.0-17.5 15 (75 onA)ds) .170 B,D,E,F,G,H,J,N,O,R,X RSSP-24MCW-FR 9402 24 16.0-33.0 15/30/75/110 .050 .081 1 .133 .161 D,E,Z RSSP-241575W-FR 7793 24 16.0-33.0 15 (75 on A)is) .065 D,E,Z RSSP-121575W-FR 7798 12 8.0-17.5 15 (75 on Axis) .170 D,E,Z RSS-24185W-FR- 8223. 24 16.0-33.0 185 .293 A,B,C,D ***RSS 24185W FR is for future release. Ll Table 2: Specifications & Ordering Information - Single Candela Ceiling Mount Model Order Code Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela Average Current* Mounting Options RSS-2415C-FW 7482 24 16.0-33.0 15 .072 B,D,E,F,H,J,N,O,R,X RSS-2430C-FW 7483 24 16.0-33.0 30 .102 B,D,E,F,aN,J,No,R,x RSS-2475C-FW 7484 24 16.0-33.0 75 .205 B,D,E,F,G1,J,N,O,R,X RSS-24100C.FW 7485 24 16.0-33.0 100 .238 B,D,E,F,al-LJ,N,o,R,X RSS-24150C-FW 8222 24 16.0-33.0 150 .293 A,BC,D RSS-24177C-FW 8230 24 16.0-33.0 177 .333 A,B,C,D Average Current per actual Wheelock Production Testing-at Listed VDC. For Rated Average and Peak current across UL regulated voltage range for both Filtered DC and unfiltered VRMS, see Installation Instructions. 0* Refer to Data Sheet S7000 for Mounting Options Table 3: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Homs AH, NH Motor Bells MB-G6/G10 Speakers ET-101011080, E70, ET70 Chimes CH70 SYNC MODULES! POWER SUPPLY Average Model Number Order Input Voltage Current Mounting Code (VDC) (AMPS) @ Options 24VDC SM12/24.R# 6369 24 .025 W DSM-12/24-R" 6374 24 .038 W PS-12/24-8 8114 120 VAC # SM Sync Module is rated for 3.0 amperes @ 24 VDC. ## DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM Modules is twenty (20). • Refer to Data Sheet S3000 or Installation Instructions (P83123) for Styl and P83177 for DSM). ### Refer to Data Sheet S9001 or Installation Instructions P83862 for PS-12/24-8 Power Supply. WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83911) SERIES RSS/RSSP-24MCW, (P84022 AND P84025) S SERIES RSS/RSSP SINGLE CANDELA AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL EFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams SERIES RSS/RSSP APPLIANCE FROM + TO NEXT PRECEDING APPLIANCE - APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WI DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE NAC .0 SYNC CIRCUIT OUT Ø*INI RSS RSS RSS MINUS I 0. ]ROBE AUDIBLE MINUS 2 0 + IN 2 RSS RSS RSS NAC O+ OUT 2 I CIRCUIT RETURN TO NEXT I FROM APPLIANCE PRECEDING OREOLR STROBE/PLATE APPLIANCE, SYNC MODULE, POWER I ASSEMBLY SUPPLY OR FACP + AUDIBLE & VISIBLE APPLIANCE SF5055 I OPERATE IN UNISON I + + + - — ------ STROBE/PLATE IS ASSEMBLY I-tt~'I AUDIBLE & VISIBLE APPLIANCE STROBE APPLIANCE OPERATE INDEPENDENTLY SERIES RSS/RSSP APPLIANCE SYNCHRONIZED W/SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM A NAC 0— Circuit Audible SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WIMULTIPLE DSM MODULES DSM #1 Strobe NAC Cir.RSSR5S 1-10+ I I I I F I DSM #2 -H-r --"- A Strobe NAC Cir Sync Rss RSS C DSM #3 P Sync Strobe NAC , o EM DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES RSS/RSSP APPLIANCES SYNCHRONIZED W/ PS-12/24-8 Series P8-12124.8 OUTPUTS EOIR F ,. - 4-CLASS A OR AS SOS C 2-CLASS P AS RSS Saris, P5.12124.8 # For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions (P83123 for SM and P83177 for DSM). For wiring information on the PS-12/24-8 Power Supply refer to Installation Instructions P83862. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained S and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet an d b e listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shal l b e compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RS S . The Series RSS Strobe shall be of low current design and shall have Zero Inrush. Where wall mount, Multi-Candela appliances are s p e c i f i e d , the strobe intensity shall have a minimum of four (4) field selectable settings and shall be rated per UL 1971 for: 15, 30,75 or 110 candela. The selector switch for selecting the candela shall be tamper resistant and not accessible from the front of the appliance. The 15/75 candela strobe shall be specified when 15 candela UL 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). For standard ceiling mount applications, the strobe intensity shall be 15, 30, 75, or 100 candela. For high intensity wall mount applications, furnish RSS-24185W for 185cd applications. For high intensity ceiling mount applications provide RSS-24150C for 150cd applicaitons or RSS-24177C for 177cd applications. When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-12/24-8 Power Supply with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the s y n c module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single-gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification A p p l i a n c e Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Applianc e s h a l l not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mountin g , o r the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. SPECIFICATION AND ORDERING INFORMATION Model Order Code Wall Mount Ceiling Mount Non- Sync Sync wl SM,DSM or ps-12/248 Strobe Candela 24 VDC 12 VDC # Model Color RED # Model Color WHITE RSS-24MCW-FR 9400 X X X 15130/751110 X X RSS-241575W-FR 7471 X X X 15 (75 on Axis) X X RSS-1'21575W-FR 7476 X X X 15 (75 on Axis) X X RSS-2415C-FW 7482 X X X 15 X X RSS-2430C-FW 7483 X X X 30 X X RSS-2475C-FW 7484 X X X 75 X x RSS-24100C-FW 7485 X X X 100 X X RSSWP-2475W-FR 9013 X X X 75@-31F X X RSSP-121575W-FR 7798 X X X 15 (75 on Axis) X X RSSP-24MCW-FR 9402 X X X 15/30/75/110 X X RSSP-241575W-FR 7793 X X X 15 (75 on Axis) X RSS-24150C-FW 8222 X X X 150 X X RSS-24177C-FW 8230 X X X 177 X X RSS24185WFR** 8223 X X X 185 X X # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. For Weatherproof Series RSS Strobe specifications see data sheet S9004. **RSS-24185W-FR is for future release. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3 YEAR WARRANTY Made in USA Distributed By: NATIONAL SALES OFFICE 1-800-631-2148 . ,.-• __ Canada 800 397-5777 - E-mail: Info@wheelockinc.com http://www.wheelockinc.com WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740. 732-222-6880 • FAX: 732-222-2588 S0410 03/02 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 8ranchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732)"222-8707 DESIGN: Models RS-2415W, RS-241575W, RSP-241 5W, RSP-241 575W Strobe Light; Models RSS-241 5W, RSS-2475W, RSS-241 575W, ASS-2430W, RSS-241 lOW, RSSP-241 5W, RSSP-2475W, RSSP-241575W, RSSP-2430W, RSSP-2411OW, RSS-1215W, RSSP- 1215W, RSS-121575W, RSSP-1 21575W, RSS-241 5C, RSSP-2415C, RSS-2430C, ASSP-2430C, RSS-2475C, RSSP-2475C, RSS-241 OOC, RSSP-241000, RSS-24MCW and *RSSP24MCW synchronized or non-synchronized Strobe Lights. Model number may be followed by any two alpha/numeric characters indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 20-31 VDC/FWR *Rss24Mcw, RSSP-24MCW: 16-33 VDCIFWR Candela 15=15cd, 1575 =15/75cd on axis, 30=30cd, 75=75cd, 110= hOed (Wall) *RSS24MCW RSSP-24MCW: Selectable 1 5cd, 30cd, 75cd or ll0cd Flash rate 60 Flashes/minute . INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models with -Ware intended for wall mount only. Models with -C are intended for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only. For synchronization strobes, Models SM-i 2/24, SMX-1 2/24, DSM-1 2/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Rev. 06-0-2000 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an e n d o r s e m e n t o r recommendation of the item listed. This listing should not be used to verify correct operational requirements o r i n s t a l l a t i o n criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 24, 2001 Listing Expires June 30, 2002 Authorized By: NEN00, Supervising Deputy Program Manager HEPS SERIES They come in four different lens colors; clear, red, blue, or amber. The clear lens produces the highest light output, approximately 15 candela. Each glass globe has a cast iron guard for protection against external damage. Description The HEPS-W series is wall mounted and the The HEPS Series Explosion Proof strobe HEPS-C is ceiling mounted. They both utilize an is a low current consumption signal de- explosion proof junction box with (4) 1/2" conduit signed specifically for 24Vdc Fire Alarm openings. The junction box is standard with all Control Panels. HEPS explosion proof strobes. Ordering bformatk, - Technical Data Model Part Description [ File No. GGNI<5970 Number Numb,r - UL Rating Suilablo for use in Division 1 HEPS-24-C-C 372-0246 24Vdc, ceiling mount clear lens or 2: Class I Groups C Li; HEPS-24-W-C 372.11247 24Vdc. wall mount, clear lens HEPS-24-C-A :372-0254 24Vdc, ceiling mount, red lens f-IEPS-24•W-Ft 372-0255 24Vdc, wall mount, rod lens HEIS 24 C 372-0256 24Vdc coiling rneunf bluu Itiribi HEPS-24-W-8 372-0259 24Vdc, will mount, blue lorro HEPS24.C-A 372-0256 24Vdc. cslinri mount amber lens 24Vdc, wall mount, ambe' Ions l-lEPS-24-W-A 372-0267 Class II, Groups E, F, 0 Operating Voltage 24Vdc polarized Nominal Current 500 mA Inrush Current 14 amp (50 microseconds duraiior Average Power 9.6 Watt' Temperature Range -40 to .185 degrees C. Relative Humidity 95% Non-condensing Shipping Weight 9 lbs. (Ceiling), 13 lbs. (Wall) FROM : HARRINGTON_SJl3NAL,..iNc FAX NO. : 3097974573 Jun. 05 2002 02:28PM P2 Harrington Signal Inc. 2519 41h Avenue, Moline, Illinois 61265 COhlliaa I P.O. Box 590, Moline, Illinois 81266-0590 M0G6itjrnrjiit Phone: (800) 577-5758 Local: (309) 782-0731 Fax: (309) 76282l5 SyOi _______________ Internet: www.harringtonfire.com - ---------- Fetoros UL, CSFM approved Made in the USA Meets NFPA requirements Rated for Class I, Groups C, D; Class II, Groups E, F, G Polarized 24Vdc operating voltage Low current draw Two flashes per second 15 Candela light output Durable cast iron housing Protective cast iron globe guard Large back box for easy installation Wall or ceiling mounting units 1/2" conduit openings Clear, Red. Blue, or Amber color lens rIOTICO Tip Ir,l ,iIt>ogiaIreO e two ciocun>ow IG ntncieOorrly titi uoiimi'y .tr'i >jn in ch,ni will out Tt dvinn d'ln, u' lh d0.nmait lava pocltwlG6tiGciIGn nIuote IiIcIicUvGrvO,iou6leciinIcGI iimuOluuin urnS i;rrIhy lrfru,'nur,. Ci nflh inGruuwworoera iwuanowi proac1 warnun3 LimIlØnb 0u,cinwnr, wliirhu5ocuu,utIri mflorr,ani nf.,,miioru n puuuv,$d will rho v lGu>tl 016 6vir11t410 nun 11ntnOinn wQnn' er. '' Ainr,,. lnlnrtrur,,, u.,,uiu,uuuuuu in rn.,n,r thul,uuuuiunu Ohiuulul L'o Gfl8Ildbolow awc,irr, 0 U6lfI0tfl0 tltLtUOl. l-olluflrioiufllo(iflii(uofl niar su>ncui CipC01t>IflQ tw1113f pr0o16m5corwoci liarrogiun Sigoanne. hiu111iI9iuu Sujuourri; h1v AIOIl 11v1v"hci1u 'huh thii0hQo, pcclflciuianu whrnani I, Iic, Ouuhity n1ar,uIfQ1uf6J0y h'lain3r00 Shona], Inc AD#96-0306 0500 1 of I 96-0306.p65 FROM : HARRINOTON_SIGNAL,_INC FAX NO. : 3097974673 Jun. 05 2002 02:29PM P3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . LISTING SERVICE a*, LISTING No. 73000476:115 Page 1 of 1 CATEGORY: Misc. Device/Control Unit Accessories LISTEE: Harrington Signal, 2519 4th Ave., Moline IL 61268-0590 Contact: Andrew Keller (309) 782-0731 DESIGN:*Models HEPS24-C-C, HEPS-24-C-R HEPS-24C-B, HEPS-24-C-A, HEPS-24.W- C, HEPS-24-W-R. HEPS-24.W-A and HEPS-24-W-A strobes. Medals with suffix 24-C are for ceiling mount and Models with suffix 24-W are for wall mount. Units are intended for general signaling purposes. Refer to listee's data sheet for detailed product description and.oporatlon& considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation Instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for general signaling. Suitable for Class I, Group C and D; Class II, Group E, F and G hazardous locations. For indoor use only. NOTE: Not approved for public mode and not to be used as an evacuation signal for the hearing impaired. *Rev. 05-07-96 This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results andIor other data but does not make an Independent verification of any claims. This listing Is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to listee's data sheet, Installation InstructIons and/or other suItable Information sources. Data Issued: JUNE 5, 2000 Autho,zed By: Effective Issue date to expiration date HO, supeMsing Deputy Program Manager FROM : HARRINGTON_SIGNAL,_ INC FAX NO. : 3097974673 Jun. 05 2002 0230PM P4 S (10D HARRINGTON 878 & 879 SERIES Explosion Proof Horn Harrington Signal Inc. ISO 9001 - P.O. &x 590, Moline, Illinois 61266-0590 Certified 2519 4th Avenue, Moline, Illinois 61265 Management (309) 762.0731, Fax: (309) 762-8215, www.hrringtonsignaLcom System * UL & CS1M Listed for Division ] and Division 2 hazardous locations. Compact low silhouette design. Diode-polarized models available. + AC and DC operation. Low current drain. High dB output. l)l:('klpTIoN The Harrington hazardous, location horn is a heavy duty, high decibel vibrating barn in1nded for usC if) hazardous locations. U is available for AC or DC opera- tion. Individual models are UL listed for installation in a wide range of hazardotu locations — thus helping to simplify and reduce inventory. Models for hti.ardous locations are riot sound adjustable. FEATURE'S 1-ligh efficiency with low current drain. Wide operating voltage range (-20% to +15% of nominal voltage) Every unit UL listed for use in Class 1 Division I & 2. Groups f, C and D; Class 11 Division I & 2. Groups E, F & G Class Ill locations. I ligh d13 output; 100 dB at 10 ft.. Wide range at operating voltages available. Cat. No. 87DfX-N5 & 79DX-G I are diode polarized, audible signaling appliances primarily intended for use. in ha,.ardous location applications requiring electrical supervision of signaling circuit field wiring. These signals may also be used for unsupervised signaling appliances. APPLI(.'AT1ONS For use in dusty, hazardous atmospheres where it divinctive, urgent signal is required for miming, scheduling paging and general alarm applications. Typical applications include use in mines, petroleum plants, gas plants, grain elevatorS, flour mills, paper mills, textile plants and tankers. Hazardous location models not available as weatherproof. Manutaclwød by Gonoral Signal INSTALLATION' Mounts to any solid surface using two bolts. Each unit is fitted with sealed wires and is tapped for X' conduit. 7.5 "•• 11b7) •••Co) . MiJPTNO\J 6-1 (611 1160 l. T (Z) ........ 1i .................../ ACET8 f• . I .QAPMO'NPQW€R 3 J CONNECTION WIA6 j PEDPD IN Ji AOPrAwoMN flAENUCOMPUUNO (n , •"\ ;.\ p*W1M SOIJ*Cl *IU I H I t I1 (VOLTAGe NT*UPIU ON 01 t I U? ADAPTA$ONN 111.41111 -- .1 1" 'MDOU (IV) CONDUIT ........r----i OUTlET SO 4NO MOT uRNIqI1Io) t_.j VUI1NII,IEOl AD780-0690 Rev, 6198 S FROM : HARRINOTON_SIGNRL,.JNC FAX NO. 3097974673 Jun. 05 2002 02:30PM PS Cat. No. Volts AC Amps - VA. DC Coil Res. (Ohms) -- (II it) ft. 6V AC* 250 15 0.38 100 - 878EX-l5 12V AC* I .25 15 I .45 1 00 24V AC 0.625 15 - 5.2 -IOU 878IEX-N5 120V AC 0.125 IS 1,50.0 IOU 878EX-10 240V AC 0.065 IS 50.() 100 878D1EX.-N5 Supervised I20V AC' 0. 13 16 150.0 1 00 * 50/60 Hz NJ.(.)..)I "IS Cat. No. Volts DC Amps VA DC Coil Res. (Ohms) dft U) It 879EX-CI 6V DC 0.7() 15 1.4 - IOU 79X-1 I2V DC 0.27 3.5 60 lOt) 879EX-GI 24V DC 0,16 - 3.5 74.0 I0() 879EX-fl 32V ix: 0.10 3.5 4()() 100 879EX-K1 4V DC 007 3.5 96.0 lOU 125V DC 0.025 15 600.0 100 879EXS1 250V DC 0.013 3,5 2400.0 100 879DEX-G I Supervised 24V DC 0.16 1.0 20.0 - 100 INSTALLATION All models nioiirn to any solid si,rfaco using two hult.. lacli unit is litied with sealed wires aad is tapped for /" conduit. Harrington Signal Inc. reserves the right to change specifications without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1388:133 Page 1 of 1 CATEGORY: Audible Signal Devices LISTEE: GS Building Products, 6411 Parkland Drive, Sarasota, FL 34243 Contact: Leon Newsome (941) 739-4276 DESIGN: Models 878EX, 878DEX, 879EX, 879DEX, 888D, 889D and CS231 1 series vibrating horns for use in Class I, Group B, C, D and Class II Group E, F, and G indoor hazardous locations. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with the listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Model designation, electrical rating, UL label and one of the following name brands: Edwards, Edwards Systems Technology (EST), Mirtone, Fire Alarm and Systems Technology (FAST) or Alarm Industry Products (Alp). 0 APPROVAL: Listed as audible devices for use with separately listed compatible control units If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1993 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. NOTE: Formerly 7135-0073:134 11-15-93 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 14, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager I 1*!JL!!!!! Power-Limited Multiple Conductor/Unshielded DESCRIPTION ASTM bare copper PVC insulation pair or cabled construction • PVC fillers as required Polyester binders as required ' Overall 750 C PVC jacket RATING U Constructed in accordance with UL Standard 1424 Complies with UL 1666 Vertical Temperature range: Meets 300 volt requirements as specified in Section 760 of the NEC S 50 -v-WEST PENN WIRE /CDT UL listed NEC type FPIR .H' inch mm inch mm inch mm 1084 6 22 Solid .010 .25 .020 .51 .179 4.55 Shaft (riser) Flame Test 17.5 WM' 1086 8 22 Solid .010 .25 .020 .51 .193 4.90 -20° C to 75° C dry locations 17.5 WM 980 1 18 Solid .010 .25 .020 .51 .156 3.96 Pair 6.5 924 982 4 18 Solid .010 .25 .020 .51 .188 4,78 6.5 f2X 984 6 18 Solid .010 .25 .020 .51 .224 5.69 6.5 dIM' 986 8 18 Solid .010 .25 .020 .51 .252 6.40 6.5 dIM 988 10 18 Solid .010 .25 .020 .51 .294 7.47 6.5 dIM' 990 1 16 Solid .010 .25 .020 .51 .165 4.19 Pair 4.1 dIM' 992 4 16 Solid .010 .25 .020 .51 .213 5.41 4.1 ON 994 1 14 Solid .012 .30 .025 .64 .205 5.21 Pair 2.6 dIM' 700 4 14 Solid .012 .30 .025 .64 .250 6.80 2.6 dIM' 998 1 12 Solid .012 .30 .025 .64 .235 5.97 Pair 1.8 d/M' COLOR CODE Standard spool size 1000 feet 011 Black 6 Yellow 2 Red 7 Purple 3 Brown 8 Green 4 Blue 9 Red/Black 5 Orange 10 Red/White JACKET: Red APPLICATIONS Indoor (non-conduit per NEC) for: Audio circuits Control circuits Initiating circuits Notification circuits SPECIAL NOTES Select cables are available in outdoor and direct burial versions. See Aquaseal® product line for details Orange ripcord under jacket Catalog No. 980, 982, and 990 are also available with a Blue, Green, White or Yellow jacket Constructed in accordance 1 inch mm inch mm mth mm pt/ft pf/nf 609808 1 18 Solid .010 .25 .015 .38 .142 3.61 29 95, Pair 6.5 WM 60982B 4 18 Solid .010 .25 .015 .38 .175 4.45 29 95 40 6.5 DIM 609918 1 16 Solid .010 .25 .015 .38 .161 4.09 32 105 Pair 4.1 c2/M 601648 4 16 Solid .010 .25 .015 .38 .220 5.59 32 105 4.1 Q4 60993B 1 14 Solid .012 .30 .015 .38 .191 486 35 115 Pair 2.6 DIM 601008 4 14 Solid .012 .30 .015 .38 .252 6.40 35 115 2.6 filM 60995B 1 12 Solid .012 .30 .015 .38 .225 5.72 45 148 Pair 1.8 fi/M Standard spool size 1000 feet Capacitance between conductors. . LFt) tftL*WC L2.1L L2 LL11LTh (fl Power - Limited /Unshielded DESCRIPTION Plenecon liExtra Flexible • ASTM bare copper IIFPLPII Polymer alloy insulation Twisted pair or cabled construction Polyester binders as required • Flexible plenum jacket RATING UL listed NEC type FPLP with UL Standard 1424 Complies with UL 910 test modified ASTM Steiner Tunnel Test Meets 300 volt requirement as specified in Section 760 of the NEC APPLICATIONS Indoor (non-conduit per NEC) within ducts, plenums, and other spaces used for environmental air for: Audio circuits Control circuits Initiating circuits Notification circuits SPECIAL NOTES Capacitance of unshielded cable may vary depending on the installation environment. INSTALLATION PRECAUTIONS for plenum cable: refer to the Technical Reference Section COLOR CODE 1. Black, 2. Red, 3. Brown, 4. Blue JACKET: Red 54 -b-WEST PENN WIRE /CDT fl LISTING No: CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7161-0859:101 Page 1 of 1 Power-Limited Cable West Penn Wire, P0 Box 762, Washington PA 15301 Contact: *Diane Kelley (724) 222-7060 Listee's name, type, NEC rating and UL label. Listed as power-limited fire protective signaling cable. Types FPL and FPLP power limited fire protective signaling cable. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. *Rev. 06-12-2001 ( -- This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test '- results and/or other data but does not make an independent verification of any claims This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation - criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy 0 Program Manager