HomeMy WebLinkAbout1890 RUTHERFORD RD; ; FS130018; PermitCity of Carlsbad Fixed Systems Permit Permit No: FS130018 1890 RUTHERFORD Job Address: RD Permit Type: FIXSYS Parcel No: 2121203500 Lot #: 0 Reference No.: PC #: Status: APPROVED Applied 7/18/2013 Approved: 7/22/2013 Issued: 7/22/2013 Inspector: Project Title: GENOPTIX CTCE INSTALL FULLY AUTO ANSUL, INERGEN (IC- 541) FIRE SUPPRESSION SYSTEM WITH BATTER BACKUP IN SERVER ROOM 1902 Applicant: JAM FIRE PROTECTION INC 8254 RON SON RD SAN DIEGO CA 858-495-2328 858-495-2335 Owner: PDG CARLSBAD 47&48 L P 1825 GILLESPIE WAY #102 EL CAJON CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 370 0 370 0 Fire Protection, Inc. 8254 Ronson Rd. San Diego, CA. 92111 Phone (858) 495-2335, Fax (858) 496-3820 Project Info: ,i Genoptix - CTCE 1890 Rutherford Rd. Carlsbad, CA. 92008 Scope of Work: Installation of an Ansul, Inergen (IG-541), Inert Gas Fire Suppression System in Server Room 1902. The Inergen system will utilize an Autopulse. Z-10, agent release control panel for the detection and control functions. Design By: Steve Wylie 858-495-2335 StevewyIiejamfire.com BLANK PAGE S 0 Hydraulic Flow CaIcs for the Ansul, Inergen System C S 0 ANSUL INERGEN DESIGNER UL listed EX4510, FMRC Approved (J.I.)2Y0A9.AF. ULC listed CEx1151 Version 2.1.2 File: Data file name: C:\Bruce DeushaneJAM\Active Projects1 -JAM SDGenoptix\Genoptix FIXED.inr Job Number 13SRW2859F for Genoptix - CTCE Address: 1890 Rutherford Rd. Carlsbad CA 92008 Country: USA Agent Storage Conditions Storage pressure is 2175 psia at 70 degrees Fahrenheit. 439 cubic feet of INERGEN stored in each of 3 cylinders. Total agent in storage is 1317 cubic feet. Time to discharge 1185 cubic feet (90% of INERGEN) is 68.4 seconds Maximum pressure downstream of manifold orifice is 1226 psia Concentrations 95% Maximum Minimum Requested Time Cu Ft Concentration Concentration Concentration Area Volume (sec) INERGEN at Max. Temp. at Mm. Temp. at Min Temp. Server Room 2495.5 46 1317.0 41.4% at 75°F 40.5% at 60°F 34.2% at 60°F Sea level equivalent oxygen: 12.3% at 75°F Concentrations are based on altitude of 100 ft mean sea level. 0 Free Vent Calculation Peak Maximum Wall Minimum Free Area Rate Strength Vent Area Server Room 2795.6 cfm 5.0 lbs./sq.ft. 107 sq. in. Pressure Drop Results Sec Sec Nominal Length Equiv Elev Tee! Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psia psia (cfm) 1 2 1!2 40T 0.0 38.0 0.0 MFLD 1033 999 501.6 2 3 1 80T 1.0 2.6 0.0 MELD 999 999 1003.2 3 4 1 80T 1.0 2.6 0.0 MFLD 999 995 1504.8 4 5 1 80T 1.5 5.5 0.5 MFLD 995 991 1504.8 5 6 ORIFICE .344 INCHES DRILL NO. 11/32 991 423 1504.8 6 7 1 40T 3.5 3.5 3.5 423 574 1504.8 7 8 1 40T 4.4 7.0 0.0 574 567 1504.8 8 301 1 40T 1.0 6.2 -1.0 SIDE 567 565 752.1 1 (Continued) ANSUL INERGEN DESIGNER • UL listed EX4510, FMRC Approved (J.l.) 2Y0A9.AF. ULC listed CEx1151 Version 2.1.2 File: Data file name: C:\Bruce Deushane\JAM\Active Projects\1-JAM SDGenoptix\Genoptix FIXED.inr Job Number: 13SRW2859F Pressure Drop Results (Continued) Sec Sec Nominal Length Equiv Elev Tee! Start Term Flow Start End Pipe Size (if) Length(ft) (if) Mfld psia psia (cfm) 8 9 1 40 T 7.8 9.5 0.0 THRU 567 568 752.7 9 302 1 401 1.0 3.6 -1.0 568 567 752.7 Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Pipe and Fittings Sec Sec Nominal Length Side Thru Unions! EqI Start End Pipe Size (if) 90's Tee Tee Cplgs (if) 1 2 1/2 40T 0.0 0 0 0 0 Cyl Valve 38 ft 2 3 1 801 1.0 0 0 1 0 3 4 1 801 1.0 0 0 1 0 S 4 5 1 801 1.5 1 0 1 0 5 6 1 801 0 0 0 0 Man. Orifice 6 7 1 401 3.5 0 0 0 0 7 8 1 401 4.4 1 0 0 0 8 301 1 401 1.0 0 1 0 0 8 9 1 401 7.8 0 0 1 0 9 302 1 40T 1.0 1 0 0 0 Nozzle Performance Summary Nozzle Nominal Drill Drill Quantity (cu if) Area Number Pipe Size Number Diameter Discharged Name 301 1 40 T S 0.348 659.3 Server Room 302 1 40 T S 0.348 657.7 Server Room Messages/Errors ANSUL 150 bar INERGEN DESIGNER Version number 2.1.2 Calculation based on fixed nozzle and pipe sizes. 0 2 (Continued) ANSUL INERGEN DESIGNER UL listed EX4510, FMRC Approved W.I.) 2Y0A9.AF. ULC listed CEx1151 Version 2.1.2 File: Data file name: C:\Bruce DeushaneJAM'Active Projects1-JAM SDGenoptixGenoptix FIXED.inr Job Number: 13SRW2859F Messages/Errors (Continued) Calculation done on 7/16/2013 at 11:56:04 AM Concentrations are based on an altitude of 100 ft above mean sea level. Altitude correction factor is 1.00 Pipe schedule selected for pipe sizes downstream of the manifold orifice is based on the maximum pipe pressure for Grade A-53B, A-I 06B Seamless. To determine if other grades are acceptable, verify that the maximum pipe pressures for other grades are equal to or greater than the maximum anticipated downstream pressure. Calculation by JAM Fire Protection Bruce Deushane 1930 S. Myrtle Ave. Monrovia CA 91016 USA Telephone: 626-256-4400 Fax: 626-256-4401 S 0 3 End of Printout ANSUL INERGEN DESIGNER Version 2.1.2 File: Data file name: C:\Bruce Deushane\JAM\Active Projects1 -JAM SD\GenoptixGenoptix FIXED.inr Job: 13SRW2859F Customer: Genoptix - CTCE Address: 1890 Rutherford Rd. Carlsbad CA 92008 Country: USA Hazard Area Information Area: Server Room Design concentration 34.2% at 600 Fahrenheit Estimated maximum concentration 41.3% at maximum hazard temperature 75° Fahrenheit Net volume of enclosure 2495.5 cubic feet Minimum INERGEN required 1065.6 cubic feet Approximate INERGEN supplied 1317. cubic feet Flooding factor .427 cubic feet of INERGEN per cubic feet of enclosure volume Maximum allowable wall strength 5.0 lbs./sq.ft. Area consists of one volume Volume 1: Length 17.5ftWidth 15.5 ft Height 9.2ft 2 nozzles. Nozzle identifiers: 301, 302 Agent Storage Conditions Number of cylinders: 3 each containing 439 cubic feet of INERGEN. agent 1317 cubic feet • Total Engineering units (ft, cu ft, psia) are specified Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Calculation based on fixed nozzle and pipe sizes Pipe Data Input Sec Sec Nominal Length Elev 90's Side Thru Union! Noz EqI Start End Pipe Size (ft) (ft) Tee Tee Cplg Dia (ft) 1 2 1/2-40T 0.01 0.00 0 0 0 0 38.00 2 3 1 - 80 1 1.00 0.00 0 0 1 0 2 cyl 0.00 3 4 1 - 80 1 1.00 0.00 0 0 1 0 3 cyl 0.00 4 5 1 - 80 T 1.50 0.50 1 0 1 0 3 cyl 0.00 5 6 1-801 0.00 0.00 0 0 0 0 Orifice 6 7 1 -401 3.50 3.50 0 0 0 0 0.00 7 8 1 - 40 T 4.40 0.00 1 0 0 0 0.00 8 301 1-40T 1.00 -1.00 0 1 0 0 0.348 0.00 8 9 1 - 40 T 7.80 0.00 0 0 1 0 0.00 9 302 1-401 1.00 -1.00 1 0 0 0 0.348 0.00 0 1 (End of Data Input File Printout) S S BLANK PAGE Ansul, Inergen (IG-541 150 Bar INERT GAS FIRE SUPPRESSION SYSTEM DATA SHEETS S S 0 BLANK PAGE