Loading...
HomeMy WebLinkAbout2501 PALOMAR AIRPORT RD; ; AS130005; Permit6/13/22, 4:27 PM AS130005 Permit Data City of Carlsbad Sprinkler Permit 2501 PALOMAR Job Address: AIRPORT RD Permit Type: SPRINK Parcel No: Lot #: 0 Reference No.: Permit No: AS130005 Status: ISSUED Applied 1/10/2013 Approved: 1/11/2013 Issued: 1/11/2013 PC #: Inspector: Project Title: CALIFORNIA BANK & TRUST NEW FS UNDERGROUND Applicant: MANSON ENGINEERING SUITE 200 3322 SWEETWATER SPRINGS BL SPRING VALLEY, CA 619-670-6777 Owner: Fees ($) Add'I Fees ($) Total ($) Balance ($) 694 0 694 0 Ti I IV. Fire Hydrant Flow Test Results A waterilow test on the 16-inch main in El Camino Real was conducted by Schirmer Engineering. Refer to the attached water map showing the water main locations in the vicinity of the site and the location of the test. At the time of the test the water level in the elevated tank was unknown. The water department considers these to be normal conditions for this area. The results appear to be consistent with the distribution system and water supplies for the area. No impairment appears to be present. Test I Date and Time March 9, 2010 at 11:15a.m. Initial Static Pressure (psi) 108 Residual Pressure (psi) 102 Final Static Pressure (psi) 108 Total Waterflow (gpm) 1592 Number & Size of Hydrant Butts Two 2%-inch Pitot Pressure (psi) 25 /30 Nozzle Coefficient Pollard LPD-250A diffuser chart Pressure Hydrant Location Hydrant at the southwest corner of Palomar Airport Road and El Camino Real. Pressure Hydrant Elevation - 285 feet above M.S.L. Flow Hydrant Location 1st hydrant south of Palomar Airport Road on El Camino Real. (Hydrant is on site in front of Spa Bldg.) Flow Hydrant Elevation - 285 feet above M.S.L. The proposed store F.F.E. is 284 feet above M.S.L. The following graph summarizes the results of the waterfiow test Lowe's of Carlsbad, CA -11- Survey Date: March 9, 2010 The use and distribution of this document are expressly limited by the terms of the disclaimers incorporated herein. 12 11 101 go 80 70 LU 60 C,) Cl) LU cc 50 40 30 20 ic n Available Water Supply Graph Lowe's Carlsbad, CA i 1592 GPM, lozps..... - Test By SEC Test Date March 09, 2010 Results Pressure Flow 108 0 102 1592 - 20 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 FLOW - GPM Lowe's of Carlsbad, CA -12- Survey Date: March 9, 2010 The use and distribution of this document are expressly limited by the terms of the disclaimers incorporated herein. A d 91 flH Calexico Mega Park Fire Hydrant Flow Test Calculations 8/1712011 F 937-001 Fire Hydrant Flow Test Date March 9, 2010 Flow Test Results Static Pressure Residual Pressure Hydrant Flow 108 psi 102 psi 1592 gpm Actual Hydrant Elevation feet HGL 0.0 ft Estimated Hydrant Elevation 285 feet HGL 534.3 ft Equation tH =kQ185 k= 1.65E-05 Extrapolated Calculations Q, gpm Residual Pressure HGL 500 107.3 psi 532.6 ft 700 106.7 psi 531.2 ft 900 105.9 psi 529.4 ft 1100 105.0 psi 527.3 ft 1300 103.9 psi 524.7 ft 1500 102.6 psi 521.9 ft 1700 101.2p81 518.6 ft 1900 99.7 psi 515.1 ft 2000 98.8 psi 513.1 ft 2100 98.0 psi 511.1 ft 2300 96.1 psi 506.9 ft 2500 94.2 psi 502.3 ft 2700 92.1 psi 497.5 ft 2900 89.8 psi 492.3 ft 3000 88.6 psi 489.5 ft Residual Pressure, psi Available Flow, gpm 0 7,594 10 7,205 20 6,798 30 6,369 40 5,914 50 5,427 60 4,899 63 4,731 65 4,616 70 4,318 75 4,001 80 3,661 85 3,291 90 2,883 95 2,418 100 1,860 102 1,592 105 1,095 \\Pacificeng\556006\Fire Hydrant Flow Test Calcs 08-17-11 .xls I Sheetl KW moo Irvine San Diego Ontario A FUSCOE Palm Springs Los Angeles E Gill FE fliUG El Centro TRANSMITTAL To: Cindy Wong Date: Jan. 7, 2013 CITY OF CARLSBAD 1 635 Faraday Ave. Project: Ca. Bank & Trust Carlsbad, CA 92008 Job #: 02725-001-01 Phone: 760-602-4662 Sent Via: N Mail Liii Overnight [II Messenger N Hand Deliver Greg Lang This material is forwarded to you for: Your Files Per Your Request E Your Review El Bid Pricing Plan Checking Fj Your Signature E Processing El Other Regarding: California Bank & Trust - UG Fire Plans Description: Four (4) UG Fire Plans One (1) Application Two (2) Flow Tests Two (2) Parsley Review Letter Comments: For review & approval. Please call if you have any questions. From: Greg Lang, P.E. Received By: Project Manager Date: Copy: full circle thinking (r 6390 Greenwich Drive, Suite 170, San Diego, CA 92122 0 tel 858.554.1500 0 fax 858.597.0335 0 www.fuscoe.com Parsley Consulting 350 West 9& Avenue, Suite 206 L00did0, California 92025-5053 Telephone (760) 745-6181 Fax(760) 745-0537 April 27, 2012 Fire Code Official City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 Subject: Plan Review for California Bank & Trust Underground, Palomar Commons, Carlsbad, California Dear Sir: We have reviewed the submittal as prepared by Fuscoe Engineering. Based on our review it is our opinion that the submittal is in substantial conformance with the applicable codes and standards in force at this time, including local adopted ordinances. We had two minor comments. The reference to number of sprinklers in a system forcing electronic monitoring of the valves, should be 20, not 100, per California Fire Code § 903.4(2). The other was the NFPA- 13 section requiring an underground test certificate is § 10.10.1(3). Both items have been redlined on the plans. Further submittal should not be required. Sincerely, 1 Kenneth W. Wagone Office Manager End (1) Working Drawings - 3 sets Note: A copy of this letter has been transmitted via e-mail to Fuscoe Engineering on April 27, 2012 file:\C:\Documents and Settmgs\Ken\Rev2 12180.001.wpd CARLSBAD FIRE PREVENTION DIVISION Permit Application Form Name of Project: California _Bank & Trust Address of job site: 2501 Palomar Airport Road Suite •# Building Permit # CB CB 12 159 Contractor Information Name Manson Engineering Construction 3322 Sweetwater Springs Blvd Address Suite *200 City Spring Valley State CA Zip 91977 Phone 619-670-6777 Fax License nd NumberA - 515911 Exp. Date 08/31/13 / Pei Do you currently have a business license on file with the City of Carlsbad? Yes or No Signature, Date Submit plans and completed permit application to: CARLSBAD FIRE PREVENTION 1635 FARADAY AVENUE CARLSBAD, CA 92008 (760) 602-4665 Fax: (760) 602-8561 Office Hours are: 7:30 AM - 5:30 PM PST Inspection Hours are: 6:30 AM 5:00 PM To Schedule an Inspection: For inspections ONLY please call (760) 602 4660, a minimum of two days in advance Calls will be returned by the end of the next business day. Re inspection fees and Hydrant Flow Test fees must be paid at the above address prior to receiving an Inspection Inspection Personnel.are prohibited bylaw from, accepting payments in the field. All payments must be made at the address above. Plan Check status Inquiries: Allow at least 10 business days for plan review comments and/or approval. This office will contact iou when the plans are approved I disapproved Please include a self-addressed stamped envelope for mail return of plans If after 10 business days you have not received a. communication from our office, you may contact us at 760-602-4665, by FAX to 760-602-8561 or e-mail us at: firemallcarIsbadca,gov Revised 1/2012