Loading...
HomeMy WebLinkAbout7819 RUSH ROSE DR; ; FA060089; Permit6/13/22, 4:52 PM FA060089 Permit Data City of Carlsbad Fire Alarm Permit 7819 RUSH ROSE Job Address: DR Permit Type: FALARM Parcel No: Lot #: 0 Reference No.: Permit No: FA060089 Status: ISSUED Applied 12/20/2006 Approved: 12/20/2006 Issued: 12/20/2006 PC #: Inspector: Project Title: LA COSTA GLEN, REC BLDG. TWO FIRE ALARM INSPECTIONS @ $62/EA Applicant: Owner: DIALCOM SYSTEM SERVICES 1541 SIMPSON WAY ESCONDIDO, CA 760-233-9787 Fees ($) Add'I Fees ($) I Total ($) Balance ($) L 124 0 124 0 1/1 4 La Costa Glen, Phase 4 - Bldgs E-F-G-H & Recreation Review Comments. Page 2 Review Comments La Costa Glen, Phase 4 - Bldgs E-F-G-H & Recreation, Rush Rose Drive, Carlsbad, California Building E Sheet FA 102, bedroom #PO 114 is missing the required audible notification device. Field verify that the proper device, similar to those found in adjacent bedrooms, is installed. No resubmittal required. Alarm current for 3-125G is shown on the catalog data sheets as 7 mA, while calculations use value of 20 mA. No revision required. Alarm current for 3MODCOM is shown on the catalog data sheets as 90 mA, while the calculations show 95 mA. No revision required. It is not possible to verify the current draws for the 3-SAC. Standby current for SIGA-CT is shown on the catalog data sheets as 369tA and the alarm current is shown as 680i.iA, while the calculations us 22 and 40 respectively. No revision required, as the battery capacity cushion is sufficient to account for the increase in current required. Standby current for SIGA-CCIS is shown on the catalog data sheets as 2234tA and the alarm current is shown as I 00.tA, while the calculations us 250 and 40 respectively. No revision required, as the battery capacity cushion is sufficient to account for the increase in current required. Standby current for SIGA-CR is shown on the catalog data sheets as 100pA and the alarm current is shown as l00.tA, while the calculations us 10 for each device. Unable to verify current for BPS bA. Recreation Building Provide additional visible notification devices in pool/spa room, as 110 cd strobes will not provide adequate notification in a public space of this size when both are located on one wall more than 55 feet from the opposite wall. Field verify, and no revision orresubmittal is required. FAOO8° FORM 2-J Automatic Sprinkler Systems Contractor's Material and Test Certificate for Aboveground Piping / Date; /ii' Property Name: 41-t Property Address: 7 ( ' 7j .+ - Procedure Upon completion of work inspection and tests shall be made by the contractor's reprsentative and witnessed by an owner's representative. All defects shall be corrected and the system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authori- ties, owners, and contractors. It is understood that the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Plans Accepted by [approving authority's name(s)] Address Installation conforms to accepted plans? W/<(es U No Equipment used Is approved? Eies U No If no, explain deviations. Instructions - Has person in charge of fire equipment been instructed as to location of control valves and care and maintenance of this new equipment? [Q-1'es If no, explain. Have copies of appropriate instructions and care and maintenance charts and NFPA 13 been left on premises? If no, explain. 0 No Li No Location of System Supplies building(s) Sprinklers Make Model Year of Manufacture Orifice Size Quantity Temperature Rating f:ef'abfr: '5P-L2vt j __ __ b'c :Ls f' F ill __ ____________ 2cO ____ ________ bi 5( C V2 Pipe and Fittings Pipe conforms to ,44 T,'7? standard, D No Fittings conform to 75 72 2 standard. ['Yes El No If no, explain. PAGE lot 3 Copyright 0 2000 National Fire Protection Association tTnnRnt uoiioaiod 0J14 rJfla4IT ?p:cn i.n ci aon V) FORM 2-J ky Automatic Sprinkler Systems Contractor's Material and Test Certificate for Aboveground Piping (cont.) Alarm Valve or Flow Indicator Alarm Device Maximum Time to Operate Through Test Pipe Type Make Model Mm. Sec. P104) 5'y71ce 1.JIP Jv Dry Pipe Operating Test Dry Valve Q.O.D. Make Model Serial No. Make Model Serial No. Time to Trip Through Test Pipe' Water Pressure Air Pressure Trip Point Air Pressure Time Water Reached Test Outlet' Alarm Operated Properly Mm. Sec. Psi (Bar) Psi (Bar) Psi (Bar) Mm. Sec. Yes I No Without Q.O.D. With Q.O.D. If no, explain. Deluge and Preactiori Valves Operation 0 Pneumatic 0 Electric 0 Hydraulic Piping supervised? D Yes LI No Detecting media supervised? 0 Yes 0 No Is there an accessible facility in each circuit for testing? 0 Yes 0 No If no, explain. Does each circuit operate supervision loss alarm? Does each circuit operate valve release? Maximum Time to Operate Release Yes No Yes No Make Model Mm. Sec. Test Description HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for two hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.2 bar) for two hours. Differential dry pipe valve clappers shall be left open during test to prevent damage. All aboveground piping leakage shall be stopped. FLUSHING: Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets such as hydrants and blow-offs. Flush at flows not less than 400 gpm (1514 1/mm) for 44n. (102-mm) pipe, 600 gpm (2271 1/mm) for 5-in. (127-mm) pipe, 750 gpm (2839 1/mm) for 6-in. (152-mm) pipe, 1000 gpm (3785 1/mm) for 8-in. (203-mm) pipe, 1500 gpm (5678 L/min) for 10-in. (254-mm) pipe and 2000 gpm (7570 1/mm) for 12-in. (305-mm) pipe. When supply cannot produce stipulated flow rates, obtain maximum available. 'Measured from time inspectors test pipe is opened. PACE 2 of 3 Copyright © 2000 National Fire Protection Association E18I'90809L uotoaojd ajij pnaiti E:60 LO 61 400 Automatic Sprmlder Systems FORM 2-i 0 Contractor's Material and Test Certificate for Aboveground Piping (cont.) Test Description (cont.) PNEUMATIC; Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 11/2 psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 11/2 psi (0.1 bar) in 24 hours. Tets All piping hydrostatically tested at 200 psi (bar) for - hrs. Dry piping pneumatically tested? [] Yes El No Equipment operates properly? 0 Yes [1 No If no, state reason. Drain test—Reading of gauge located near water supply test pipe: Static pressure: /?'-3 psi (bar) Drain test—Residual pressure with valve in test pipe open wide: psi (bar) Underground mains and lead-in connections to system risers flushed before connections made to sprinkler piping Verified by copy of the U Form No. SSB i's El No 0 Other Flushed by installer of underground sprinkler piping ["es El No El Other If other, explain. Blank Testing Gaskets Number used Locations Number removed Welding / Welded piping? i 0 No If yes, Do you certify as the sprinkler contractor that welding procedures comply with / the requirements of at least AWS D10.9, Level AR-3? Yes U No Do you certify that the welding was performed by welders qualified in com- pliance with the requirements of at least AWS Dl 0.9, Level AR-3? Yes LI No Do you certify that welding was carried out in compliance with a documented quality control procedure to insure that all discs are retrieved, that openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated? Yes 0 No Hydraulic Data Nameplate Nameplate provided? EYes 0 No If no, explain. Remarks Date left in service with all control valves open: 11-13' Sprinkler Contractor: Signatures of Test Witnesses For property owner (signed) Title Date For sprinkler contractor (signed) Title Z"vi- DateI/1 3 - PAGE 3of3 Copyright © 2000 National Fire Protection Association CI8fr90809L. uoioojd aiij pn2aiti e:30 LO GI loo