Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2303 OCEAN ST; ; FA140086; Permit
Uity 01 Uarlsbad Fire Alarm Permit Permit No: FA140086 Job Address: 2303 OCEAN ST Status: ISSUED Permit Type: FALARM Applied 7/1/2014 Parcel No: 2030102200 Approved: 8/14/2014 Lot #: 0 Reference No.: Issued: 8/14/2014 PC #: Inspector: Project Title: OCEAN ST. RESIDENCES BLDG 1 BLDG 1: SCOPE OF WORK IS A MANUAL FIRE ALARM SYSTEM. THIS PROJECT CONSISTS OF 13 BUILDINGS. ONE OF THEM IS A RECREATION BUILDING AND THE REST ARE RESIDENTIAL. THIS PROJECT IS A PRIVATE COMMUNITY IN WHICH TH EMAIN ENTRANCE IS LOCATED BY THE RECEPTION BUILDING. THE RECREATION BLDG. WILL CONTAIN THE MAIN ADDRESSABLE FIRE ALARM CONTROL UNIT WHICH WILL MONITOR THE REST OF THE BUILSINGS. THE RESIDENTIAL BUILDINGS WILL CONTAIN A HARDWIRED FIRE ALARM CONTROL PANEL THAT WILL BE SUPERVISED/MONITORED THROUGH THREE MONITOR MODULES. BUILDINGS 1-7 HAVE (1) LEVEL AND (1) PARKING LEVEL. bUILDINGS 8-13 HAVE (2) LEVELS. Applicant: Owner: ASCI SECURITY, INC. OCEAN STREET 8 OWNER LLC 42184 REMINGTON AVE ATTN:GENERAL COUNSEL TEMECULA, CA 92590 3300 P GA BLVD #820 PALM BCH GDNS FL 951-225-6363 Fees ($) Add'I Fees ($) Total ($) Balance ($) 364 0. 364 0 OCEAN STREET RESIDENCES BLDG# STREET# STREET AS# FA # CB# 1 2303 OCEAN ST AS140173 - _FAI.1.0086 CB131212 2 2309 OCEAN ST A5140174 CB131214 3 2315 OCEAN ST AS140175 FA140088 CB131216 4 2321 OCEAN ST AS140176 :FA14oOS9 CB131218 5 2327 OCEAN ST A5140177 FA140CS0 CB131220 6 2333 -23.2.7.. OCEAN ST AS140178 FA1'0CS1 CB131222 7 2339 OCEAN ST AS140179 FA1002 CB131224 8 2345 OCEAN ST AS140180 FA1L0053 I CB131226 9 2353 OCEAN ST A5140181 FA140094 CB131248 10 2363 OCEAN ST A5140182 FA140095 CB131233 11 2373 OCEAN ST A5140183 FA CB131237 12 2383 OCEAN ST AS140184 FA140097 CB131241 13 2393 OCEAN ST AS140185 FA140098 CB131245 ST P 1462e6 F4 t'461b'4 01307 L OCEAN STREET RESIDENCES if if if if if if if BLDG# if STREET# STREET AS# CB# 1 2303 OCEAN ST AS140173 - A14006 CB131212 2 2309 OCEAN ST AS140174 A1407 CB131214 3 2315 OCEAN ST AS140175 FJ140O88 CB131216 if 4 2321 OCEAN ST AS140176 :FA140089 CB131218 5 2327 OCEAN ST AS140177 zP14009C CB131220 6 2327 OCEAN ST A5140178 A140091. CB131222 7 2339 OCEAN ST A5140179 E .A14Q092 CB131224 8 2345 OCEAN ST AS140180 FA140093 CB131226 9 2353 OCEAN ST AS140181 FA140094 1 CB13 1248 10 2363 OCEAN ST AS140182 FA14009.5 CB131233 11 2373 OCEAN ST AS140183 FA1400E CB131237 12 2383 OCEAN ST A5140184 FA14C07 CB131241 13 2393 OCEAN ST AS140185 I FA14C0 CB131245 r ,w. s PROJECT SUBMITTAL FIRE SPRINKLER MONITORING SYSTEM Project Address: Ocean Street Residences 2303 Ocean Street Carlsbad, CA 92008 General Contractor: Crane Development 9605 Kearny Villa Road San Diego, CA 92126 (858) 549-3920 Fax (858) 549-3994 Submitted by & Installing Contractor: ASCI SECURITY, INC. Access Security Controls International, Inc. 42814 Remington Avenue Temecula, CA 92590 (951) 225-6363 Fax (951) 296-0875 Contractor's License No. 752872 (C 10) 0 May 16, 2014 L7 CONTENTS UL Certificate of Central Station Monitoring Equipment Data Sheets and CSFM Sheet fl' L9A CERTIFICATE OF COMPLIANCE ThIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratones Inc (UL) in its Product Directones as eligible .to use the UL Listing Mark in connection with Certificated Alarm Systems The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under. UL's Certificate Verification Service This Certificate does not apply in any way to the communication channel between the protected property and any fai1ity that monitors signals from the protected property unless the use of a IJL listed or Classified Alarm Transport Company is specified on the Certificate Listed Service From VIEJO, CA AL Alarm Service Company (2570574101) Service Center (257057-001) ADVANCED PROTECTION INDUSTRIES INC. ADVANCED PROTECTION INDUSTRIES INC, DSA NATIONAL MONITORING CENTER DBA NATIONAL MONITORING CENTER SUITE 250 SUITE 250 26800 ALISO VIEJO PKY 26800 ALISO VIEJO PKY ALISO' VIEJO CA 92656 ALISO VIEJO CA 92656 The Alarm Service Company is Listed in the f cate Service Categories File -Vol No CCN INTELLIGENT FIRE ALARM CONTROL PANELS FX-350-60-DR S Description The FX-350-60-DR Intelligent Fire Alarm Control Panel is a single loop addressable panel that supports up to 60 addressable points. The FX-350-60-DR is equipped with a two line by 20 character backlit LCD display, numerical keypad and an integrated UDACT/Digital Communicator. The LCD display allows for 32 characters to be configured for user defined messages. In addition the FX-350 Series family also includes remote LED and LCD annunciators. The FX-350-60-DR is ideal for both new and retrofit applications. Designed for small to medium commercial, institutional and industrial occupancies, these panels are powerful enough to meet today's installation demands. The FX-350-60-DR is configurable by the keypad for onsite programming or by a PC for both onsite and remote programming. Easy to install and simple to operate and configure, the FX-350-60-DR enables the installer to configure the system to meet their specific requirements. The FX-350-60-DR is equipped with a 5.5 Amp power supply, auxiliary resettable smoke power supply (300mA max.), an interface for a Remote Trouble Indicator (RTl- 1) and an RS485 interface for remote LCD and LED annunciators. The FX-350-60-DR comes complete with a red door, black enclosure, durable CAT-30 lock and key and space to mount up to 12 AH batteries. An optional trim ring is available for semi-flush mounting. Features Single Addressable SLC Loop that supports 60 addressable points Points can be any combination of Addressable Sensors or Modules Supports Ionization Sensors, Photoelectric Sensors, Variable Heat Sensors and Multi—Sensor (Heat/Photo) Equipped with a 2 line by 20 character backlit LCD display, numerical keypad and an integrated UDACT/ Digital Communicator LCD display allows for 32 characters to be configured for user defined messages Digital Communicator can be configured for DACT or UDACT mode of operation Configurable via the front panel, PC Configurator, or remote dial up through the built-in modem Sensors can be configured asAiarni, Verified Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only Modules can be configured as Alarm, Latching Supervisory, Non-Latching Supervisory, Water Flow, Monitor, Trouble, Fire Drill Switch, Signal Silence Switch, Aux Disconnect Switch and Buzzer Silence Switch Base panel is equipped with Four Class "B" (Style "B") indicating circuits which may be configured as Class "A" (Style "Z) using a Class "A" signal converter module Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock Relay contacts for Common Alarm, Auxiliary/ Alarm (Disconnectable), Common Supervisory and Common Trouble Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test SubsequentAlarm, Supervisory, and Trouble operation RS-485 Interface for Remote LED and LCD Annunciators Positive Alarm Sequence Interface for a Remote Trouble Indicator (RTI-1) Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events 5.5 Amp Power Supply Optional modules for additional internal relay circuits and City Tie/Polarity Reversal Optional trim ring for semi-flush mounting MEA City of Chicago approved S7010 7165-1477:156 313-97-E Aporoved for Class I Applications CATALOG NUMBER %JVI V NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Optional Adder Modules OCAC-304 Four Indicating Circuit Class "A" Convetter Module The OCAC-304 converts four Class UB (Style "Y") output circuits on the FX-350 to Class "A" (Style 'Z") circuits. The OCAC-304 is equipped with wire leads to connect to the FX-350 main board. Remote Annunciators PR-300 Polarity Reversal/City Tie Module The PR-300 provides outputs for city box and polarity reversal applications. As a city be module the PR-300 provides an interface between the control panel indicating circuits and a master box. As a polarity reversal module the PR-300 provides an interface between the control panel and a reverse polarity receiver. RAM-300LCDR Remote LCD Annunciator The RAM-300LCDR provides LCD remote annunciation through a 2 line by 20 character LCD display. The RAM- 300LCDR provides control switches for System Reset, Signal Silence, Fire Drill and Acknowledge as well as a numeric keypad to access the menu functions. The common control functions can be disabled on a per function basis. The RAM- 300LCDR has LED indicators forA.C. On, Alarm, Supervisory, Trouble and CPU Fail. The RAM-300LCD comes complete with a red enclosure and a CAT-30 Lock and key. RA-1 000 Series Remote LED Annunciators The RAM-1016TZ and RAM-1032TZ Remote LED Annunciators provide 16 or 32 points respectively of LED annunciation. Both models come standard with bi-coloured LEDs which are automatically configured for either Alarm (Red) or Supervisory (Amber). The annunciators have indicators forA.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. In addition both models allow for the control switches to be disabled on a per function basis. Both models mount in a BB-1001R enclosure. RAM-208RIRAM-216R Remote LED Annunciators The RAM-208R and RAM-216R provide 8 or 16 points respectively of LED annunciation. Both models feature bi-coloured LEDs which are auto-configurable for either Alarm (red) or Supervisory (amber). The LED annunciators have indicators forA.C. On, Common I- Trouble and Signal Silence and control switches for System Reset, Signal Silence, Lamp Test and Buzzer Silence. The RAM-208R and RAM-216R are equipped with a keyswitch which allows for enabling and disabling of the Common Control functions. Both models are available in a red finish and mount in a 4-gang electrical box. Dimensions FX-350-60-DR 20"H x I4WW x 4WD Ordering Information Model Description FX-350-60-DR Single Loop 60 Point Intelligent Fire Alarm Control Panel with built-in UDACT/Digital Communicator FA-300TRB Black semi-flush trim ring for FX-350-60-DR enclosure Optional Adder Modules OCAC-304 Four Indicating Circuit Class "A" Converter Module PR-300 Polarity Reversal/City Tie Module Remote Annunciators RAM-300LCDR Remote LCD Annunciator c/w enclosure. RAM-1016TZ 16 Zone Remote LED Annunciator with trouble LEDs. Mounts in an 1313-1000 Series enclosure. RAM-10321Z 32 Zone Remote LED Annunciator with trouble LEDs. Mounts in an BS-1000 Series enclosure. BB-1001R Red enclosure for RAM-1O16TZ or RAM-1032TZ Annunciators. Houses 1 module. RAM-208R 8 Zone Remote LED Annunciator RAM-216R 16 Zone Remote LED Annunciator NOT TO BE USED FOR INSTALLATION PURPOSES. hA. IiVI1llrc©rn . Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Distributed by: Web page: http://www.mircom.com Email: mail@mircom.com ISO 9001:2008 CAT. 5670 REGISTERED Rev. 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL O FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1477:0156 Page 1 of 2 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 3110 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Models FX-350-60-R, FX-350-60-DR, FX-350-126-R, FX-350-126-DR, FX-351-LW, *FX35I..LD FX-351-LDW, FX-353-LDR, FX-353-LOW and FX-350-378-DR fire alarm control units. Local, auxiliary, remote station (PPU), central station (PPU), waterfiow and sprinkler supervisory services. Refer to the listee's data sheet for detailed product description and operational considerations. System components: MD-815; FX-3501FX-351 Mainboard - with Dialer *BBX1024DS(R);Univeal Backbox MD-837; FX-350/FX-351 Mainboard - No Dialer MD-749; DSP Core Board MD-819; Power Supply Board PR-300; City Tie/Polarity Reversal TR-061; 120/240 VAC Transformer CH-613; FX-350 Backbox FX-350 Door FX-350 Deadfront S CH-643; FX-351 Deadfront FX-351 Door FX-351 Backbox MD-825; *RA)( 332 RAM-300-LCD; Remote LCD Annunciator MIX-1 0013; Priority Monitor Module MIX-101P; Mini Priority Monitory Module MIX-I OOS; Supervised Control Module MIX-I OOR; Addressable Dual Relay Output Module MIX-bOX; Isolator Kit Rev.11-14-l3gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed (j the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: November 14, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-1477:0156 Page 2 of 2 S RATING: 120 VAC, 60Hz 240 VAC, 50 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with listee's separately listed electrically and functionally compatible initiating and indicating devices as indicated in design. Refer to listee's Installation Instructions Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. This control panel meets the requirements of UL-864, 9th Edition. Rev. 11-14-13 gt 10 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct At V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: November 14, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL O FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1477:0131 Page 1 of I CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 3110 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Model MIX-31 00 photoelectric smoke detector. Refer to listee's data sheet for additional detailed product description and operational considerations RATING: Electrical: 17 to 28 VDC, 5 to 9V protocol INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a photoelectric smoke detector for use with listee's separately listed compatable fire alarm control units and listed Models MIX-2000 Series detector bases (CSFM Listing No. 7300-1477:145). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a • grease fire in the kitchen XLF: 7272-1394:0104 04-06-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL OPP O LISTING SERVICE 0 LISTING No. 7300-1477:0145 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 3110 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Models MIX-2000, -2001, and -2001 R detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as smoke detector bases for use with listee's separately listed compatible smoke detectors. Refer to listee's Installation Instruction Manual for details. XLF: 7300-1394:0114 S 04-06-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct JWV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division O CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1477:0156 Page 1 of 2 CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 3110 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Models FX-350-60-R, FX-350-60-DR, FX-350-126-R, FX-350-126-DR, FX-351-LW, *FX351..LD FX-351-LDW, FX-353-LDR, FX-353-LDW and FX-350-378-DR fire alarm control units. Local, auxiliary, remote station (PPU), central station (PPU), waterfiow and sprinkler supervisory services. Refer to the listee's data sheet for detailed product description and operational considerations. System components: MD-815; FX-350/FX-351 Mainboard - with Dialer *BBXIO24DS(R);Universal Backbox MD-837; FX-350/FX-351 Mainboard - No Dialer MD-749; DSP Core Board MD-819; Power Supply Board PR-300; City lie/Polarity Reversal TR-061; 120/240 VAC Transformer CH-613; FX-350 Backbox FX-350 Door FX-350 Deadfront FX-351 Deadfront FX-351 Door FX-351 Backbox MD-825; *RA)( 332 RAM-300-LCD; Remote LCD Annunciator MIX-10013; Priority Monitor Module MIX-1 01 P; Mini Priority Monitory Module MIX-100S; Supervised Control Module MIX-IOOR; Addressable Dual Relay Output Module MIX-IOOX; Isolator Kit *Rev. 11-14-13gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not I. an endorsement or recommendation of the item listed. This listing should not be used to verify correct NEAR operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: November 14, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-1477:0156 Page 2 of 2 RATING: 120 VAC, 60Hz 240 VAC, 50 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with listee's separately listed electrically and functionally compatible initiating and indicating devices as indicated in design. Refer to listee's Installation Instructions Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. This control panel meets the requirements of UL-864, 9th Edition. Rev. 11-14-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: November 14, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN Program Coordinator Fire Engineering Division Specifications * Using Active End of Line Resistors (Refer to the installation and operation manual for more information. Indicating Circuits Power limited I 24VDC unfiltered I1.7A © 49°C per circuit. Maximum 5 Amps. Aux supply (non resetable) Power limited / 22.3VDC regulated I 500mA max 4-wire smoke supply (resetable) Power limited!22.3VDC regulated I 300mA max Unfiltered supply (full wave rectified) Power limited / 24VDC unfiltered / 1.7A max at 49°C Auxiliary Relays (Common alarm/supvltrb/ and auxiliary second alarm) FormC / 28VDC I 1A max. . AC Input 120VAC @ 60Hz! 240VAC © 50Hz Standby Power 24VDC standby batteries Charging Capability 4t0 12 A Current Consumption MI Standby FA-300-6D(D) 142 mA (112 mA*) 312 mA (282 mA*) FA-301-12DD 174mA (104 mA*) 444 (394 mA*) Ordering Information Model Description Control Panels FA-300-6DR Six Zone LCD Display Fire Alarm Control Panel FA-300-6DDR Six Zone LCD Display Fire Alarm Control Panel with built-in UDACT/Digital Communicator FA-301-12DDR Twelve Zone LCD Display Fire Alarm Control Panel with built-in UDACT/Digital Communicator Remote Annunciators and modules RAM-300LCDR Remote LCD Annunciator (Red enclosure) RAM-300LCDW Remote LCD Annunciator (White enclosure) RAM-208R Eight zone Remote LED Annunciator RAM-216R Sixteen zone Remote LED Annunciator RAM-1016 Sixteen zone Remote LED Annunciator RAM-10I6TZ Sixteen zone Remote LED Annunciator with individual Trouble LEDs SRM-312R Remote Relay Module with red enclosure RTI-1 Remote Trouble Indicator BB-1001R Red enclosure for RAM-1016/RAM-1016TZ BB-1001S Semi-Flush Stainless Steel Enclosure for RAM-1016/RAM-1016TZ BB-I001WPR Red Semi-Flush Weatherproof Enclosure for RAM-1016/RAM-I016TZ TH-101 Heater Kit for use with BB-I001WPR Adder Modules lCAC-306 Six Initiating Circuit Class "A" Converter Module OCAC-304 Four Indicating Circuit Class "A" Converter Module OCAC-302 Two Indicating Circuit Class "A" Converter Module RM-306 Six Relay Circuit Adder Module RM-312 Twelve Relay Circuit Adder Module PR-300 Polarity Reversal/City Tie Module ELRX-300 Active End-of-Line Resistor ELRX-300R Active End-of-Line Resistor with red mounting plate Accessories FA-300TRB Black Semi-Flush Trim Ring for FA-300-6 enclosures FA-UNlV-TRB Black Universal Semi-Flush Trim Ring for FA-301-12 enclosures FA-300-DF Dead Front for FA-300-6DRJFA-300-6DDR FA-301-DF Dead Front for FA-301-12DDR UIMA Universal Programming Tool BA-104 12 Volt, 4 Ah Battery -2 pcs required per panel BA-1065 12 Volt, 7.2Ah Battery -2 pcs required per panel BA-110 12 Volt, 12 A Battery -2 pcs required per panel NOT TO BE USED FOR INSTALLATION PURPOSES. IA MIRQM® . Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Distributed by: Web page: http://www.mircom.com Email: mail@mircom.com ISO 9001:2000 REGISTERED VWF CAT. 5662 Rev. 3 C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM Nv LISTING SERVICE 01 LISTING No. 7165-1477:0129 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 3110 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Models FA-301-12DDR, FA-300-6DDR, FA-300-6DR, FA-301-I2LD (R) (, FA-301-12L (R) (, FA-301-81-DW, and FA-301-81-Wfire alarm control units. Local, auxiliary, remote station (PPU), central station (PPU) services. Refer to the listee's data sheet for detailed product description and operational considerations. System components: PR-300 Polarity Reversal and City Tie Module RM-312 12 Relay Adder Module RM-306 6 Relay Adder Module SRM-312(R) (V\l) Smart Relay Module, Red/White Enclosure RAM-300LCD (R) (V)l Remote LCD Annunciator, Red/White Enclosure lCAC-306 Input Class A Converter, 6 Circuits OCAC-304 Output Class A Converter, 4 Circuits OCAC-302 Output Class A Converter, 2 Circuits ELRX-300 (R) (VV) Active End of Line Resister, Red/White Plate ELRX-300 Active End of Line Resister, No Plate RAM-216 16 Zone Remote Annunciator RAM-208 8 Zone Remote Annunciator BBX-I024DSR Back Box *Models FA301-12DDR, FA300-6DDR, FA30I-12LDR may have a different Back Box model BBX-1 O24DSR. RATING: I20VAC, 60Hz; 240VAC, 50Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. *Updated 10-2-13 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or' other data but does not make an independent verification of any claims. This listing is not ia an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-1477:0129 Page 2 of 2 - NOTE For Fire Alarm Verification Feature (delay of fire alarm skinal) the maximum o Retard/Reset/Restart period shall not exceed 30 seconds. *Updated 10-2-13 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used -to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of I CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Models 2W-B, 2WT-B, 4W-13 and 4W1-B photoelectric type smoke detectors. Models 2W-B and 2Wr-B are 2-wire and model 4W-13 and 4WT-B are 4-wire detectors. Models 2W1-B and 4Wr-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM o LISTING SERVICE LISTING No. 7125-0785:0131 Page 1 of 2 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: ModelsAS-1215, -2415,-1230,-2430,-121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -Ware for wall mount only. *Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and *AswP..2475C audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *ASWLID..24MC\NH and *AS\PJ24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listees data sheet for detailed product description and operational considerations. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct CAW V11 operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7125-0785:0131 41 Page 2of2 RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:l5cd,1575:15/75cd,30:30cd,75:75cd,95:95cd, 100:100cd, 110:ll0cd MCW: Selectable 15cd, 30cd, 75cd,110cd MCC: Selectable 15cd, 30cd,75cd,95cd MCWH: Selectable 135cd,185cd (65cd, 90cd at -40 C) MCCH: Selectable 115cd,177cd (50cd, 75cd at -40 C) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP-24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix -w or \NH are for wall mount only. Models with suffix -C or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, *ASwp..2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-12124 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -I2WP and -24WP audible devices are not suitable for the hearing impaired applications. Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has •reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division ,SE CURI TY, 1 TT iV 17 CARLSBAD Ls,^,jU RECEIVED Ll JUL 17 2014 / L U K t .1 7 FTRI J)FP.tPTMT 42184 Remington Ave., Temecula, CA 92590 (951) 225-6363 (951) 296-0875 (Fax) www.ascisecurity.com Letter of Transmittal Carlsbad Fire Department To: 1635 Faraday Avenue From: Ron Pysher Carlsbad, CA 92008 Phone: Greg Ryan (760) 602-4663 Chris Wilson (760) 602-4665 Pages: Fire Alarm Drawings, 2nd Submittal Fax: Date: July 16, 2014 Ocean Street Residences Re: 2303 Ocean Street, Carlsbad, CA cc: Permit # FA140086 0 Urgent 0 Your Use X Re-Submittal 0 Please Reply 0 Please Recycle Please find herewith 3 sets of revised fire alarm plans for the above referenced project. Attached is a sheet with the responses to the correction notice. Any assistance in expediting these would be greatly appreciated. If you have any questions, please feel free to contact me. - &,P, Respectfully, Pysher Sales Engineer (951) 225-6363 Project Revisions ENGINEERED SYSTEMS Date: 7/11/14 PROJECT NAME: Ocean St. Residences RESPONSE TO REV: 1 ITEM (.]I'AII REPONSE Strobes and horn strobes have been incorporated into 1 Provide occupant notification per spec for the parking garage area. the design. Two NAC circuits have been added to the parking area. Please see FA.05 & FA.06 2 Provide occupant notification device in fitness room and any other enclosed common use area. Fitness room has now been covered with audio visual devices. Please see FA. 3 Provide the appropriate level of smoke or heat detection in closed parking garage and all enclosed utility The Elevator will not be traveling more than 25ft. rooms. Therefore Smoke detection coverage will not be required for the control of the elevator. 4 Provide appropriate level of smoke/heat detection in stairwells that communicate between the garage The buildings above the parking level are only two (U/S-1)and the residences above unless there is a minimum of two rated separations. level buildings. When traveling from the parking level up to the 1st level of the residential building via the stairs, there will be direct access to Ocean street. Therefore there will be no need for smoke detection. 5 The plans submitted do not include a garage sheet or a lagoon level sheet (oversight maybe). A garage sheet has been incorporated into the drawings please see FA.05 6 Please revise the plans accordingly including battery calcs and resubmit. Battery calculations and counts have been revised accordingly with the changes. Please see floor plans and Battery calculations.