Loading...
HomeMy WebLinkAbout2775 OCEAN ST; ; FA090036; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA090036 Job Address: 2775 OCEAN ST Permit Type: FALARM Parcel No: 2032350200 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 7/13/2009 Approved: 7/13/2009 Issued: 7/13/2009 Inspector: Project Title: BEACH TERRACE INN TWO FIRE ALARM INSPECTIONS @ $65/EA Owner: TOBO INVESTMENTS Applicant: CROSSWAY FIRE PROTECTION SUITE 302 2801 CAMINO DEL RIO SO SAN DIEGO, CA 619-702-3473 2785 ROOSEVELT ST CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 Parsley Consulting 350 West 9th Avenue, Suite 206 Escondido, California 92025-5053 Telephone (760) 745-6181 F4(760) 745-0537 July 1, 2009 Mr. James Weigand City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 Subject: Plan Review for Beach Terrace Inn Alarm System, 2775 Ocean Street, Carlsbad, California Dear Mr Weigand: We have reviewed the submittal as prepared by Crossway Fire Protection. Based on our review it is our opinion that the submittal is in substantial conformance with the applicable codes and standards in force at this time, including local adopted ordinances. Further submittal should not be required, other than the renewed CSFM listings for the equipment to be installed, which expired yesterday (June 30, 2009). This can be pryid at final inspection. Sincerely, XPEY ,OULTJNG Kenneth W. WagoneT Office Manager End (1) Working Drawings - 2 sets Product Submittals - 2 sets Review Comments - 1 set Note: A copy of this letter has been transmitted via fax to Crossway Fire Protection on July 1, 2009 fiIe:\S:\REVIEWS'Jev2O9220.002.wpd Beach Terrace Inn Alarm System Review Comments. Page 2 Review Comments Beach Terrace Inn Alarm System, 2775 Ocean Street, Carlsbad, California There are devices on notification circuit S2 which have an incorrect current draw in both the point-to-point diagram and the battery calculations, however the increase results in only a few milliamps in the overall battery requirement. a. Devices S2-8, S2-5, S2-9, and S2-10 are 30 cd horn/strobe assemblies, and have a current draw of 116 mA from the catalog data sheet. The calculations regard them as being 15 cd devices with a current draw of 91 mA. Battery capacity is capable of providing the increased draw from that shown on the plan. We strongly recommend the following operational tests be performed once the system installation has been completed. A "power off" test, where the normal power supply is shut off, and the system is left to function on battery power alone for a period of 24 hours, at which time the system should still be functioning and operational. At the end of the end of the above test, prior to the primary power being restored, the system should be placed in an "alarm" condition for a period of not less than five minutes, during which time all notification appliances, including the off-station notification, are to function as designed. Once the two prior tests have been completed, the current level in the batteries should be checked, the primary power restored, and at the end of 48 hours the current level checked again to verify that the charging function of the panel is both operational, and able to recharge the batteries within the time period specified by NFPA-72. Once the test in item "c" has been completed, one of the leads to the battery should be disconnected, to determine that the system will provide notification of an "off-normal" power condition to the monitoring company. iL1 COP S S BEACH TERRACE FIRE ALARM EQUIPMENT SUBMITTAL LIST DEVICE QTY MODEL MANUF CSFM. PANEL (Addressable) I MS9200UDLS FIRELITE 7165-0075:208 POWER SUPPLY 1 5495 SILENT KNIGHT 7300-0559:123 ANNUNCIATOR 1 ANN-80 FIRELITE 7120-0075:222 BATTERIES 2 NA UL LISTED MODULES 2 MMF-301 FIRELITE 7300-0075:185 SMOKE DETECTORS Photoelectric. 24 SD355(A) FIRELITE 7272-0075:194 HEAT DETECTORS 1 H355(A) FIRELITE 7270-0075:195 PULL STATION 10 BG12XL FIRELITE 7150-0075:184 HORN STROBES Wall White 15-75cd 0 Horn Strobes Ceiling: White: I5-75cd 7 PC2W SYSTEM SENSOR 7135-1653:189 7125-1653:188 STROBES: Ceiling: White: 30cd 6 SCW SYSTEM SENSOR 7125-1653:186 MINI HORNS White: 13 MHW SYSTEM SENSOR 7135-1653:196 CABLE FLPP GENISIS 7161-1487:100 Cross Way Fire 619.702.3473 2801 Camino del Rio So. Suite 302 619.702.3474 fax San Diego, Ca. 92108 email: bob@crosswayfire.com [1 BEACH TERRACE FIRE ALARM EQUIPMENT SUBMITTAL LIST DEVICE QTY MODEL MANUF CSFM. PANEL (Addressable) 1 MS9200UDLS FIRELITE 7165-0075:208 POWER SUPPLY 1 5495 SILENT KNIGHT 7300-0559:123 ANNUNCIATOR 1 ANN-80 FIRELITE 7120-0075:222 BATTERIES 2 NA UL LISTED MODULES 2 MMF-301 FIRELITE 7300-0075:185 SMOKE DETECTORS Photoelectric 24 5D355(A) FIRELITE 7272-0075:194 HEAT DETECTORS 1 H355(A) FIRELITE 7270-0075:195 PULL STATION 10 BG12XL FIRELITE 7150-0075:184 HORN STROBES Wall White 15-75cd 0 Horn Strobes Ceiling: White: I5-75cd 7 PC2W SYSTEM SENSOR 7135-1653:189 7125-1653:188 STROBES: Ceiling: White: 30cd 6 SCW SYSTEM SENSOR 7125-1653:186 MINI HORNS White: 13 MHW SYSTEM SENSOR 7135-1653:196 CABLE FLPP GENISIS 7161-1487:100 Cross Way Fire 619.702.3473 2801 Camino del Rio So. Suite 302 619.702.3474 fax San Diego, Ca. 92108 email: bob@crosswayfire.com