HomeMy WebLinkAboutPS 2023-0021; THE COTTAGES; Sign Permits/Programs (PS)
P-37 Page 1 of 1 Rev. 2/2022
Development Services
Planning Division
1635 Faraday Avenue
(442)339-2610
www.carlsbadca.gov
Certificate of Accuracy
P-37
Project Name__________________________
Type of permit(s) applying for____________________________
CITY OF CARLSBAD - PLANNING DIVISION
CERTIFICATE OF ACCURACY
I certify all documents and plans clearly and accurately show all existing and
all proposed buildings, structures, access roads, and utilities/utility
easements. All proposed land use activities, improvements to land, and/or
building modifications or additions are clearly labeled on the site plan of the
approved plan set. I understand that any potentially existing detail within
these plans inconsistent with the site plan are not approved and may be
required to be altered or removed. The submitted documents and plans show
the correct dimensions of the property, the buildings, and structures and their
setbacks from property lines and from one another, access roads/easements,
and utilities. The existing and proposed use of land and of each building as
stated is true and correct. Further, all improvements existing on the property
were completed in accordance with all regulations in existence at the time of
their construction, unless otherwise noted. All easements and other
encumbrances to development have been accurately shown and labeled as
well as all on-site grading/site preparation.
Applicant: _______ Date: _____________
Signage
The Cottages
Kenney Signs (Matthew Kenney)2/24/2023
1
Client:Project:Revisions:Project No:
Date:
Sign Type:
Sheet No:
00
00
00
of 10
1565CREEKSTREET
SUITE105
SANMARCOS,CA92078
760-459-1119
C-45Lic.#1082555
KS_220458
2022-09-03 09/03/22
COLOR DISCLAIMER
Due to the limitations of desktop scanners and the relative inconsistencies of various display monitors and printers, the colors you see on your screen or on paper
may not be a totally accurate reproduction of the actual product. We strive to make our colors as accurate as possible, but screen and printed images are intended
as a guide only and should not be regarded as absolutely correct. Site conditions and onsite lighting can also affect how the product appears (i.e. LED, different
Florescent bulbs, Natural Light, Backlit, Halolit, Facelit). We recommend that you request a color sample as CMYK (Cyan, Magenta, Yellow and Black) are the
colors used in the printing process, whereas RGB (Red, Green and Blue) are the colors used by screen displays such as your monitor. For this reason and due to
variations introduced by light and various equipment, the colors on your screen or a print may not exactly match the finished product.
If you would like to see a sample of any color, please request an actual sample from your Salesperson or Project Manager.
WITHOUT A SIGNED COLOR SAMPLE, KENNEY SIGNS, ITS VENDORS AND AFFILIATES ARE NOT RESPONSIBLE FOR DIFFERENCES, REAL OR PERCEIVED, BETWEEN THE WAY
YOUR PRODUCT APPEARS ON SCREEN OR PAPER AND THE FINAL PRODUCT.
Client Name (Please Print) _________________________ Date ____/____/____
Client Name (Signature) ____________________________________________
PLEASE INITIAL ALL PAGES
KS Drawing #1 Rev. #00 Rev. Date: 00-00-00
Pages: 10 (Including Cover Sheet)
Approved
Revise & Resubmit
Approved as Noted
Rejected
Cottages on Roosevelt
Prepared for:
Project Address:
2956 ROOSEVELT ST.
Carlsbad, CA 92008
United States
Tenant:
Shoots
Revolution Roasters
The Plot
Stella Jeans
Landlord/Property owner:
Jeffrey C. Rasak
President and Chief Executive Officer
Sterling Development Corporation
Rancho Santa Fe Plaza
162 S. Rancho Santa Fe Rd., Suite B-85
Encinitas, CA 92024
ph: (760) 633-0006 fax: (760) 633-0072
e-mail: Sterlingdevelopment@yahoo.com
Legal Description:
APN Number: 2033042700
Legal: BLK 38*LOTS 6 THRU 8\
Conceptual Package
Production Package
Permit Package
B
C
A
Scope of Work / Contents:
3
Sign
Description
Sign
Number Page
FRONT LIT CHANNEL LETTERS
4
SIGN TYPE SIGN NUMBER QTY SQ FTDIMENSIONSILLUM
35.4624”X212.75”01Face-lit Channel Letters w/
Push-Thru Tagline Y NA
27
44.14
NA
30”X206”
71.625” x 88.75"
01
01
01
Vinyl
Push Through Cabinet
Drive-Thru
N
Y
Y
A
B
D1
Sign Schedual:
FRONT LIT CHANNEL LETTERS
FRONT LIT CHANNEL LETTERS W/ FCO TAGLINE
5
file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\
document title: 11x 17HorizTitleblock20190103a
PS2023-0021
4/12/2023
2
Client:Project:Revisions:Project No:
Date:
Sign Type:
Sheet No:
00
00
00
of 10
1565CREEKSTREET
SUITE105
SANMARCOS,CA92078
760-459-1119
C-45Lic.#1082555
KS_220458
2022-09-03 09/03/22
file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\
document title: 11x 17HorizTitleblock20190103a
Site Plan
SP1.00
SITE PLAN
SCALE: NTS1
NORTH
This is an original unpublished drawing created by KENNEY SIGNS. It is
submitted for your personal use in conjunction with a project being planned for
you by KENNEY SIGNS. It is not to be shown to anyone outside your organization,
nor is it to be used, reproduced, copied or exhibited in any fashion without
written permission from KENNEY SIGNS
REV2
CAR
L
S
B
A
D
V
I
L
L
A
G
E
D
R
.
R
O
O
S
E
V
E
L
T
S
T
CARL
S
B
A
D
V
I
L
L
A
G
E
D
R
.
M
A
D
I
S
O
N
S
T
M
A
D
I
S
O
N
S
T
CIVIC
C
E
N
T
E
R
D
R
.
GRA
N
D
A VE.
9.00"3/16”=1’
B
C
A
2956 ROOSEVELT ST.
CARLSABAD, CA 92008
COTTAGESONROOSEVELT
3file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\
document title: 11x 17HorizTitleblock20190103a
SIGN B1 - FACELIT CHANNEL LETTERS WITH FCO TAGLINE - QTY: [01] ILLUMINATED
SCALE: 1”=1’
Sign B1
B1.00
This is an original unpublished drawing created by KENNEY SIGNS. It is
submitted for your personal use in conjunction with a project being planned for
you by KENNEY SIGNS. It is not to be shown to anyone outside your organization,
nor is it to be used, reproduced, copied or exhibited in any fashion without
written permission from KENNEY SIGNS
NIGHTVIEW
QUANTITY:ONE (1)
OVERALL HEIGHT: 2’
OVERALL LENGTH: 9’-1 3/4”
TOTAL SQ.FT.:218.29 ft
RETURNS: .040 ALUMINUM - 3” HUNTER RED
BACKS:.063” ALUMINUM (LETTERS)
TRIMCAP:3/4” RED
FACE:3/16” 7328 WHITE ACRYLIC W/ VINYL OVERLAY
VINYL:3M 3630-53 CARDINAL RED
ILLUMINATION:WHITE LEDS
REV2
COLOR SPECIFICATIONS:
V1:3M 3630 - 53 CARDINAL RED
P1:PMS 200c
FCOs:1/2” ACRYLIC PAINTED PMS 200c
9.00"
3/16”=1’
PAINT TOMATCHPMS 200C
PURE WHITE - LED
#7328 WHITE ACRYLIC
POWER SUPPLY
DISCONNECT
PRIMARY POWER WITHIN 6’ (BY OTHERS)
1
2
5
6
7
¼” DRAIN HOLES10
11 .040 ALUM. RETURNS
15 .063 ALUMINUM BACKS
16 WEATHER-PROOF ELECTRICAL PASS-THROUGH
MOUNTING HARDWARE (4 PER LETTER)9
FACE LIT CHANNEL LETTERS
1
2
3
11
5
7
9
10
3”
6
15
16
3/4” TRIMCAP3
flat cut out letters
2956 ROOSEVELT ST.
CARLSABAD, CA 92008
COTTAGESONROOSEVELT
1'-3"
9'-1 3/4"
5'-2 1/2"
0'-4 1/4"
ThissignisintendedtobeinstalledinaccordancewiththerequirementsofArticle600oftheNationalElectricalCodeand/orotherapplicablelocalcodes.Thisincludespropergroundingandbondingofthesign.
____ Dedicated ____ Amp Circuit at _____ Volts201201
REQUIREMENTSFORELECTRICALILLUMINATION:E-Note #1: All requirements not in sign company’s
scope of work must be in place prior to installation.
E-Note #2: Electrical to be brought to base of sign(by others) and not in sign company's scope of work.
E-Note #3: Timers and/or photocells for signs to be
furnished and installed by the customer's electrician,
who should also ensure that the completed electrical
system is code compliant.
ALL COMPONENTS TO BE APPROVED
ALL SIGNS TO BE LISTEDThelocationofthedisconnectswitchafterinstallationshallcomplywith
Article600.6(A)(1)oftheNationalElectricalCode.
PROPOSED CONDITIONS
20'-3”
Client:Project:Revisions:Project No:
Date:
Sign Type:
Sheet No:
00
00
00
of 10
1565CREEKSTREET
SUITE105
SANMARCOS,CA92078
760-459-1119
C-45Lic.#1082555
KS_220458
2022-09-03 09/03/22
4file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\
document title: 11x 17HorizTitleblock20190103a
SIGN C1 - FACELIT CHANNEL LETTERS - QTY: [01] ILLUMINATED
SCALE: 3/4”=1’
Sign C1
C1.00
This is an original unpublished drawing created by KENNEY SIGNS. It is
submitted for your personal use in conjunction with a project being planned for
you by KENNEY SIGNS. It is not to be shown to anyone outside your organization,
nor is it to be used, reproduced, copied or exhibited in any fashion without
written permission from KENNEY SIGNS
NIGHTVIEW
QUANTITY:ONE (1)
OVERALL HEIGHT: 1’- 2”
OVERALL LENGTH: 14’
TOTAL SQ.FT.:216.33 ft
RETURNS: .040 ALUMINUM - 3” PTM PMS 2757c
BACKS:.063” ALUMINUM (LETTERS)
TRIMCAP:3/4” BLUE
FACE:3/16” 7328 WHITE ACRYLIC W/ VINYL OVERLAY
VINYL:3M 3635-210 PRINT TO MATCH 2757
ILLUMINATION:WHITE LEDS
REV4
COLOR SPECIFICATIONS:
V1:
PURE WHITE - LED
#7328 WHITE ACRYLIC
POWER SUPPLY
DISCONNECT
PRIMARY POWER WITHIN 6’ (BY OTHERS)
1
2
5
6
7
¼” DRAIN HOLES10
11 .040 ALUM. RETURNS
15 .063 ALUMINUM BACKS
16 WEATHER-PROOF ELECTRICAL PASS-THROUGH
MOUNTING HARDWARE (4 PER LETTER)9
FACE LIT CHANNEL LETTERS
1
2
3
11
5
7
9
10
3”
6
15
16
3/4” TRIMCAP3
2956 ROOSEVELT ST.
CARLSABAD, CA 92008
COTTAGESONROOSEVELT
ThissignisintendedtobeinstalledinaccordancewiththerequirementsofArticle600oftheNationalElectricalCodeand/orotherapplicablelocalcodes.Thisincludespropergroundingandbondingofthesign.
____ Dedicated ____ Amp Circuit at _____ Volts201201
REQUIREMENTSFORELECTRICALILLUMINATION:E-Note #1: All requirements not in sign company’s
scope of work must be in place prior to installation.
E-Note #2: Electrical to be brought to base of sign(by others) and not in sign company's scope of work.
E-Note #3: Timers and/or photocells for signs to be
furnished and installed by the customer's electrician,
who should also ensure that the completed electrical
system is code compliant.
ALL COMPONENTS TO BE APPROVED
ALL SIGNS TO BE LISTEDThelocationofthedisconnectswitchafterinstallationshallcomplywith
Article600.6(A)(1)oftheNationalElectricalCode.
PROPOSED CONDITIONS
20'-3”
1'-1 1/4"
13'-2 3/4"
Client:Project:Revisions:Project No:
Date:
Sign Type:
Sheet No:
00
00
00
of 10
1565CREEKSTREET
SUITE105
SANMARCOS,CA92078
760-459-1119
C-45Lic.#1082555
KS_220458
2022-09-03 09/03/22
5file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\
document title: 11x 17HorizTitleblock20190103a
SIGN D1 - FACELIT CHANNEL LETTERS - QTY: [01] ILLUMINATED
SCALE: 1 1/2”=1’
Sign D1
D1.00
This is an original unpublished drawing created by KENNEY SIGNS. It is
submitted for your personal use in conjunction with a project being planned for
you by KENNEY SIGNS. It is not to be shown to anyone outside your organization,
nor is it to be used, reproduced, copied or exhibited in any fashion without
written permission from KENNEY SIGNS
NIGHTVIEW
QUANTITY:ONE (1)
OVERALL HEIGHT: 2’ w/decender on letter “p”, Letter Height is 17 1/4”
OVERALL LENGTH: 7’-1”
TOTAL SQ.FT.:214.17 ft
RETURNS: .040 ALUMINUM - 3” BLACK
BACKS:.063” ALUMINUM (LETTERS)
TRIMCAP:3/4” BLACK
FACE:3/16” 7328 WHITE ACRYLIC W/ VINYL OVERLAY
VINYL:3M 3635-222 DUAL COLOR FILM
ILLUMINATION:WHITE LEDS
REV2
COLOR SPECIFICATIONS:
V1:
V2:
3M VINYL 3630-115
9.00"
3/16”=1’
PAINT TOMATCHPMS 200C
PURE WHITE - LED
#7328 WHITE ACRYLIC
POWER SUPPLY
DISCONNECT
PRIMARY POWER WITHIN 6’ (BY OTHERS)
1
2
5
6
7
¼” DRAIN HOLES10
11 .040 ALUM. RETURNS
15 .063 ALUMINUM BACKS
16 WEATHER-PROOF ELECTRICAL PASS-THROUGH
MOUNTING HARDWARE (4 PER LETTER)9
FACE LIT CHANNEL LETTERS
1
2
3
11
5
7
9
10
3”
6
15
16
3/4” TRIMCAP3
DUAL COLOR BLACK
CITRON YELLOW
express
2'-7 1/4"
2956 ROOSEVELT ST.
CARLSABAD, CA 92008
COTTAGESONROOSEVELT
7'-1"
PROPOSED CONDITIONS
20'-3”20'-3”
Client:Project:Revisions:Project No:
Date:
Sign Type:
Sheet No:
00
00
00
of 10
1565CREEKSTREET
SUITE105
SANMARCOS,CA92078
760-459-1119
C-45Lic.#1082555
KS_220458
2022-09-03 09/03/22
ThissignisintendedtobeinstalledinaccordancewiththerequirementsofArticle600oftheNationalElectricalCodeand/orotherapplicablelocalcodes.Thisincludespropergroundingandbondingofthesign.
____ Dedicated ____ Amp Circuit at _____ Volts201201
REQUIREMENTSFORELECTRICALILLUMINATION:E-Note #1: All requirements not in sign company’s
scope of work must be in place prior to installation.
E-Note #2: Electrical to be brought to base of sign(by others) and not in sign company's scope of work.
E-Note #3: Timers and/or photocells for signs to be
furnished and installed by the customer's electrician,
who should also ensure that the completed electrical
system is code compliant.
ALL COMPONENTS TO BE APPROVED
ALL SIGNS TO BE LISTEDThelocationofthedisconnectswitchafterinstallationshallcomplywith
Article600.6(A)(1)oftheNationalElectricalCode.
1'-5 1/4"
8.8"