Loading...
HomeMy WebLinkAboutPS 2023-0021; THE COTTAGES; Sign Permits/Programs (PS) P-37 Page 1 of 1 Rev. 2/2022 Development Services Planning Division 1635 Faraday Avenue (442)339-2610 www.carlsbadca.gov Certificate of Accuracy P-37 Project Name__________________________ Type of permit(s) applying for____________________________ CITY OF CARLSBAD - PLANNING DIVISION CERTIFICATE OF ACCURACY I certify all documents and plans clearly and accurately show all existing and all proposed buildings, structures, access roads, and utilities/utility easements. All proposed land use activities, improvements to land, and/or building modifications or additions are clearly labeled on the site plan of the approved plan set. I understand that any potentially existing detail within these plans inconsistent with the site plan are not approved and may be required to be altered or removed. The submitted documents and plans show the correct dimensions of the property, the buildings, and structures and their setbacks from property lines and from one another, access roads/easements, and utilities. The existing and proposed use of land and of each building as stated is true and correct. Further, all improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. All easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. Applicant: _______ Date: _____________ Signage The Cottages Kenney Signs (Matthew Kenney)2/24/2023 1 Client:Project:Revisions:Project No: Date: Sign Type: Sheet No: 00 00 00 of 10 1565CREEKSTREET SUITE105 SANMARCOS,CA92078 760-459-1119 C-45Lic.#1082555 KS_220458 2022-09-03 09/03/22 COLOR DISCLAIMER Due to the limitations of desktop scanners and the relative inconsistencies of various display monitors and printers, the colors you see on your screen or on paper may not be a totally accurate reproduction of the actual product. We strive to make our colors as accurate as possible, but screen and printed images are intended as a guide only and should not be regarded as absolutely correct. Site conditions and onsite lighting can also affect how the product appears (i.e. LED, different Florescent bulbs, Natural Light, Backlit, Halolit, Facelit). We recommend that you request a color sample as CMYK (Cyan, Magenta, Yellow and Black) are the colors used in the printing process, whereas RGB (Red, Green and Blue) are the colors used by screen displays such as your monitor. For this reason and due to variations introduced by light and various equipment, the colors on your screen or a print may not exactly match the finished product. If you would like to see a sample of any color, please request an actual sample from your Salesperson or Project Manager. WITHOUT A SIGNED COLOR SAMPLE, KENNEY SIGNS, ITS VENDORS AND AFFILIATES ARE NOT RESPONSIBLE FOR DIFFERENCES, REAL OR PERCEIVED, BETWEEN THE WAY YOUR PRODUCT APPEARS ON SCREEN OR PAPER AND THE FINAL PRODUCT. Client Name (Please Print) _________________________ Date ____/____/____ Client Name (Signature) ____________________________________________ PLEASE INITIAL ALL PAGES KS Drawing #1 Rev. #00 Rev. Date: 00-00-00 Pages: 10 (Including Cover Sheet) Approved Revise & Resubmit Approved as Noted Rejected Cottages on Roosevelt Prepared for: Project Address: 2956 ROOSEVELT ST. Carlsbad, CA 92008 United States Tenant: Shoots Revolution Roasters The Plot Stella Jeans Landlord/Property owner: Jeffrey C. Rasak President and Chief Executive Officer Sterling Development Corporation Rancho Santa Fe Plaza 162 S. Rancho Santa Fe Rd., Suite B-85 Encinitas, CA 92024 ph: (760) 633-0006 fax: (760) 633-0072 e-mail: Sterlingdevelopment@yahoo.com Legal Description: APN Number: 2033042700 Legal: BLK 38*LOTS 6 THRU 8\ Conceptual Package Production Package Permit Package B C A Scope of Work / Contents: 3 Sign Description Sign Number Page FRONT LIT CHANNEL LETTERS 4 SIGN TYPE SIGN NUMBER QTY SQ FTDIMENSIONSILLUM 35.4624”X212.75”01Face-lit Channel Letters w/ Push-Thru Tagline Y NA 27 44.14 NA 30”X206” 71.625” x 88.75" 01 01 01 Vinyl Push Through Cabinet Drive-Thru N Y Y A B D1 Sign Schedual: FRONT LIT CHANNEL LETTERS FRONT LIT CHANNEL LETTERS W/ FCO TAGLINE 5 file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\ document title: 11x 17HorizTitleblock20190103a PS2023-0021 4/12/2023 2 Client:Project:Revisions:Project No: Date: Sign Type: Sheet No: 00 00 00 of 10 1565CREEKSTREET SUITE105 SANMARCOS,CA92078 760-459-1119 C-45Lic.#1082555 KS_220458 2022-09-03 09/03/22 file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\ document title: 11x 17HorizTitleblock20190103a Site Plan SP1.00 SITE PLAN SCALE: NTS1 NORTH This is an original unpublished drawing created by KENNEY SIGNS. It is submitted for your personal use in conjunction with a project being planned for you by KENNEY SIGNS. It is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without written permission from KENNEY SIGNS REV2 CAR L S B A D V I L L A G E D R . R O O S E V E L T S T CARL S B A D V I L L A G E D R . M A D I S O N S T M A D I S O N S T CIVIC C E N T E R D R . GRA N D A VE. 9.00"3/16”=1’ B C A 2956 ROOSEVELT ST. CARLSABAD, CA 92008 COTTAGESONROOSEVELT 3file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\ document title: 11x 17HorizTitleblock20190103a SIGN B1 - FACELIT CHANNEL LETTERS WITH FCO TAGLINE - QTY: [01] ILLUMINATED SCALE: 1”=1’ Sign B1 B1.00 This is an original unpublished drawing created by KENNEY SIGNS. It is submitted for your personal use in conjunction with a project being planned for you by KENNEY SIGNS. It is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without written permission from KENNEY SIGNS NIGHTVIEW QUANTITY:ONE (1) OVERALL HEIGHT: 2’ OVERALL LENGTH: 9’-1 3/4” TOTAL SQ.FT.:218.29 ft RETURNS: .040 ALUMINUM - 3” HUNTER RED BACKS:.063” ALUMINUM (LETTERS) TRIMCAP:3/4” RED FACE:3/16” 7328 WHITE ACRYLIC W/ VINYL OVERLAY VINYL:3M 3630-53 CARDINAL RED ILLUMINATION:WHITE LEDS REV2 COLOR SPECIFICATIONS: V1:3M 3630 - 53 CARDINAL RED P1:PMS 200c FCOs:1/2” ACRYLIC PAINTED PMS 200c 9.00" 3/16”=1’ PAINT TOMATCHPMS 200C PURE WHITE - LED #7328 WHITE ACRYLIC POWER SUPPLY DISCONNECT PRIMARY POWER WITHIN 6’ (BY OTHERS) 1 2 5 6 7 ¼” DRAIN HOLES10 11 .040 ALUM. RETURNS 15 .063 ALUMINUM BACKS 16 WEATHER-PROOF ELECTRICAL PASS-THROUGH MOUNTING HARDWARE (4 PER LETTER)9 FACE LIT CHANNEL LETTERS 1 2 3 11 5 7 9 10 3” 6 15 16 3/4” TRIMCAP3 flat cut out letters 2956 ROOSEVELT ST. CARLSABAD, CA 92008 COTTAGESONROOSEVELT 1'-3" 9'-1 3/4" 5'-2 1/2" 0'-4 1/4" ThissignisintendedtobeinstalledinaccordancewiththerequirementsofArticle600oftheNationalElectricalCodeand/orotherapplicablelocalcodes.Thisincludespropergroundingandbondingofthesign. ____ Dedicated ____ Amp Circuit at _____ Volts201201 REQUIREMENTSFORELECTRICALILLUMINATION:E-Note #1: All requirements not in sign company’s scope of work must be in place prior to installation. E-Note #2: Electrical to be brought to base of sign(by others) and not in sign company's scope of work. E-Note #3: Timers and/or photocells for signs to be furnished and installed by the customer's electrician, who should also ensure that the completed electrical system is code compliant. ALL COMPONENTS TO BE APPROVED ALL SIGNS TO BE LISTEDThelocationofthedisconnectswitchafterinstallationshallcomplywith Article600.6(A)(1)oftheNationalElectricalCode. PROPOSED CONDITIONS 20'-3” Client:Project:Revisions:Project No: Date: Sign Type: Sheet No: 00 00 00 of 10 1565CREEKSTREET SUITE105 SANMARCOS,CA92078 760-459-1119 C-45Lic.#1082555 KS_220458 2022-09-03 09/03/22 4file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\ document title: 11x 17HorizTitleblock20190103a SIGN C1 - FACELIT CHANNEL LETTERS - QTY: [01] ILLUMINATED SCALE: 3/4”=1’ Sign C1 C1.00 This is an original unpublished drawing created by KENNEY SIGNS. It is submitted for your personal use in conjunction with a project being planned for you by KENNEY SIGNS. It is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without written permission from KENNEY SIGNS NIGHTVIEW QUANTITY:ONE (1) OVERALL HEIGHT: 1’- 2” OVERALL LENGTH: 14’ TOTAL SQ.FT.:216.33 ft RETURNS: .040 ALUMINUM - 3” PTM PMS 2757c BACKS:.063” ALUMINUM (LETTERS) TRIMCAP:3/4” BLUE FACE:3/16” 7328 WHITE ACRYLIC W/ VINYL OVERLAY VINYL:3M 3635-210 PRINT TO MATCH 2757 ILLUMINATION:WHITE LEDS REV4 COLOR SPECIFICATIONS: V1: PURE WHITE - LED #7328 WHITE ACRYLIC POWER SUPPLY DISCONNECT PRIMARY POWER WITHIN 6’ (BY OTHERS) 1 2 5 6 7 ¼” DRAIN HOLES10 11 .040 ALUM. RETURNS 15 .063 ALUMINUM BACKS 16 WEATHER-PROOF ELECTRICAL PASS-THROUGH MOUNTING HARDWARE (4 PER LETTER)9 FACE LIT CHANNEL LETTERS 1 2 3 11 5 7 9 10 3” 6 15 16 3/4” TRIMCAP3 2956 ROOSEVELT ST. CARLSABAD, CA 92008 COTTAGESONROOSEVELT ThissignisintendedtobeinstalledinaccordancewiththerequirementsofArticle600oftheNationalElectricalCodeand/orotherapplicablelocalcodes.Thisincludespropergroundingandbondingofthesign. ____ Dedicated ____ Amp Circuit at _____ Volts201201 REQUIREMENTSFORELECTRICALILLUMINATION:E-Note #1: All requirements not in sign company’s scope of work must be in place prior to installation. E-Note #2: Electrical to be brought to base of sign(by others) and not in sign company's scope of work. E-Note #3: Timers and/or photocells for signs to be furnished and installed by the customer's electrician, who should also ensure that the completed electrical system is code compliant. ALL COMPONENTS TO BE APPROVED ALL SIGNS TO BE LISTEDThelocationofthedisconnectswitchafterinstallationshallcomplywith Article600.6(A)(1)oftheNationalElectricalCode. PROPOSED CONDITIONS 20'-3” 1'-1 1/4" 13'-2 3/4" Client:Project:Revisions:Project No: Date: Sign Type: Sheet No: 00 00 00 of 10 1565CREEKSTREET SUITE105 SANMARCOS,CA92078 760-459-1119 C-45Lic.#1082555 KS_220458 2022-09-03 09/03/22 5file path: \\ADS11\Design\ADS Drawings\Widget Control Center\job 12345\ document title: 11x 17HorizTitleblock20190103a SIGN D1 - FACELIT CHANNEL LETTERS - QTY: [01] ILLUMINATED SCALE: 1 1/2”=1’ Sign D1 D1.00 This is an original unpublished drawing created by KENNEY SIGNS. It is submitted for your personal use in conjunction with a project being planned for you by KENNEY SIGNS. It is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without written permission from KENNEY SIGNS NIGHTVIEW QUANTITY:ONE (1) OVERALL HEIGHT: 2’ w/decender on letter “p”, Letter Height is 17 1/4” OVERALL LENGTH: 7’-1” TOTAL SQ.FT.:214.17 ft RETURNS: .040 ALUMINUM - 3” BLACK BACKS:.063” ALUMINUM (LETTERS) TRIMCAP:3/4” BLACK FACE:3/16” 7328 WHITE ACRYLIC W/ VINYL OVERLAY VINYL:3M 3635-222 DUAL COLOR FILM ILLUMINATION:WHITE LEDS REV2 COLOR SPECIFICATIONS: V1: V2: 3M VINYL 3630-115 9.00" 3/16”=1’ PAINT TOMATCHPMS 200C PURE WHITE - LED #7328 WHITE ACRYLIC POWER SUPPLY DISCONNECT PRIMARY POWER WITHIN 6’ (BY OTHERS) 1 2 5 6 7 ¼” DRAIN HOLES10 11 .040 ALUM. RETURNS 15 .063 ALUMINUM BACKS 16 WEATHER-PROOF ELECTRICAL PASS-THROUGH MOUNTING HARDWARE (4 PER LETTER)9 FACE LIT CHANNEL LETTERS 1 2 3 11 5 7 9 10 3” 6 15 16 3/4” TRIMCAP3 DUAL COLOR BLACK CITRON YELLOW express 2'-7 1/4" 2956 ROOSEVELT ST. CARLSABAD, CA 92008 COTTAGESONROOSEVELT 7'-1" PROPOSED CONDITIONS 20'-3”20'-3” Client:Project:Revisions:Project No: Date: Sign Type: Sheet No: 00 00 00 of 10 1565CREEKSTREET SUITE105 SANMARCOS,CA92078 760-459-1119 C-45Lic.#1082555 KS_220458 2022-09-03 09/03/22 ThissignisintendedtobeinstalledinaccordancewiththerequirementsofArticle600oftheNationalElectricalCodeand/orotherapplicablelocalcodes.Thisincludespropergroundingandbondingofthesign. ____ Dedicated ____ Amp Circuit at _____ Volts201201 REQUIREMENTSFORELECTRICALILLUMINATION:E-Note #1: All requirements not in sign company’s scope of work must be in place prior to installation. E-Note #2: Electrical to be brought to base of sign(by others) and not in sign company's scope of work. E-Note #3: Timers and/or photocells for signs to be furnished and installed by the customer's electrician, who should also ensure that the completed electrical system is code compliant. ALL COMPONENTS TO BE APPROVED ALL SIGNS TO BE LISTEDThelocationofthedisconnectswitchafterinstallationshallcomplywith Article600.6(A)(1)oftheNationalElectricalCode. 1'-5 1/4" 8.8"