HomeMy WebLinkAbout2510 GATEWAY RD; 101; CBC2022-0261; PermitBuilding Permit Finaled
(city of
Carlsbad
Commercial Permit
Print Date: 05/02/2023
Job Address: 2510 GATEWAY RD, # 101, CARLSBAD, CA 92009-1727
Permit No:
Status:
CBC2022-0261
Closed -Finaled
Permit Type: BLDG-Commercial
2132611513
$300,189.12
Work Class: Tenant Improvement
Parcel#:
Valuation:
Occupancy Group: B
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition: 2019
Sprinkled: Yes
Project Title:
Track#:
Lot#:
Project#:
Plan#:
Construction Type:V-B
Orig. Plan Check #:
Plan Check#:
Description: SULLY OFFICE COM-Tl: (5,208 SF) NON-STRUCTURAL
Applicant:
L7 STUDIO ARCHITECTS
JOHN LETTER
5190 GOVERNOR DR, # 204
SAN DIEGO, CA 92122-2847
(858) 952-8166
FEE
BUILDING PLAN CHECK
BUILDING PLAN REVIEW-MINOR PROJECTS (LDE)
BUILDING PLAN REVIEW -MINOR PROJECTS (PLN)
CERTIFICATE OF OCCUPANCY
COMM/IND Tl -NON-STRUCTURAL
SB1473 -GREEN BUILDING STATE STANDARDS FEE
SEWER CONNECTION FEE (General Capacity all areas)
STRONG MOTION -COMMERCIAL (SMIP)
TRAFFIC IMPACT Commercial-Industrial w/in CFD
Total Fees: $8,312.31 Total Payments To Date: $8,312.31
Applied: 07/26/2022
Issued: 10/26/2022
Finaled Close Out: 05/02/2023
Final Inspection: 04/17/2023
INSPECTOR: Kersch, Tim
Alvarado, Tony
Contractor:
VILLAGE PROPERTY SYSTEMS INC
4920 CARROLL CANYON RD, # STE 200
SAN DIEGO, CA 92121-3735
(858) 755-1800
Balance Due:
AMOUNT
$1,005.26
$194.00
$98.00
$16.00
$1,664.56
$13.00
$1,675.44
$84.05
$3,562.00
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
{'city of
Carlsbad
COMMERCIAL
BUILDING PERMIT
APPLICATION
B-2
Plan Check
Est. Value
PC Deposit
Date
No: CBC2022-0261
$300,189.12
$1,005.26
07.26.2022
Job Address 2510 GATEWAY ROAD
Tenant Name#: SULLY ASSET GROUP, LLC
Suite: APN: 213-261-15-00 _____ ,
Lot #:, ____ Year Built: _2_0_0_8 _______ _
Year Built: 2008 Occupancy:_B __ Construction Type: VB Fire sprinklers:QYESONO A/C:(:)YESONO
BRIEF DESCRIPTION OF WORK: 5,208 SF TENANT IMPROVEMENT. NO NEW AREA. MECH, ELECTRICAL, PLUMBING,
0 Addition/New: ____________ New SF and Use, __________ New SF and Use
______ SF Deck, SF Patio Cover, SF Other (Specify) ___ _
liJTenant Improvement: 5,208 SF,
_____ SF,
Existing Use: VACANT Proposed Use: OFFICE --------------Existing Use: Proposed Use: ______ _
D Other:-----------------------------------
PRIMARY APPLICANT
Name: JOHN LETTER L7 STUDIO ARCHITECTS
Address: 5190 GOVERNOR DRIVE, SUITE 204
City: SAN DIEGO State: CA Zip: 92122
Phone: 858.952.8166
Email: JOHNLETER@L7STUDIOARCHITECTS.COM
DESIGN PROFESSIONAL
Name: JOHN LETTER (L7 STUDIO ARCHITECTS)
Address: 5190 GOVERNOR DRIVE, SUITE 204
City: SAN DIEGO
Phone: 858.952.8166
State:_C_A_~Zip: 92122
Email: JOHNLETTER@L?STUDIOARCHITECTS.COM
PROPERTY OWNER
Name: SULLY ASSET GROUP, LLC
Address: 2510 GATEWAY ROAD
City: CARLSBAD State: CA Zip: 92009
Phone: 858.353.0945
Email: SULLY@SULLYENTGROUP.COM
CONTRACTOR OF RECORD
Business Name: Burger Construction, Inc.
Address: 4920 Carroll Canyon Road Suite #200
City: San Diego State:CA Zip:_9_2_1_2_1 __ _
Phone: (858) 245-3498
. bschoepp@burgercon.com
Ema1l: ___ ....,.,.,,,.,,,..,..,--------------
Architect State License: _c_3_3_74_6 _________ CSLB License #:. _______ Class:-"B'--------
Carlsbad Business License# (Required): BLOS 1204028
APPLICANT CERT/FICA T/ON: I certify that I have read the applicatianandstate that the above information is correct and that the
information on the plans is accurate. /agree to comply with all City ordinances and State laws relating to building
construction.
NAME (PRINT): JOHN LETTER ~ 07/21/2022
SIGN: -+-,"'---------DATE:-------
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov
REV. 04/22
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON
SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO
PERMIT ISSUANCE.
{OPTION A): LICENSED CONTRACTOR DECLARATION:
lherebyaffirmunderpenaltyofperjurythatlamlicensedunderprovisionsofChapter9/commencingwithSection7000/ofDivision3
of the Business and Professions Code, and my license is in fu// force and effect. I also affirm under penalty of perjury one of the
fo//owing declarations /CHOOSE ONE/:
DI have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued. PolicyNo.
-OR-
IX} I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for t'A,_performance <:the wo~ for w~c~this '<Jrmit is issued.
My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name: merlC8n 8S. 0. 0 88 1ng
Policy No. 701565471 Expiration Date: 10/1/2023
-OR-D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued {Sec. 3097 (i) Civil Code).
Lender's Name: Lender's Address:
CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and
utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site pion. Any potentially existing detai1 within these plans inconsistent with the site plan ore not
approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct
dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roods/easements, and utilities. The existing and proposed use of each building
os stated is true and correct; a// easements and other encumbrances to development have been accurately shown and labeled as well as all on·site grading/site preparation. All improvements
existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted,
NAME (PRINT): Billy Schoepp SIGNATURE:
Di;,..,.,,,.,,;s,• .. ,sc,o,o,
Billy Schoeppu~:"~~"~:.s;.:::::~i'.',',;;_':;,:;, ;,,,_,~11<>2'"""°"""''""" DATE: 10/6/2022
Note: If the person signing above is an authorized agent for the contractor provide a letter of authorization on contractor letterhead .
• •
{OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
□ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
-OR-
DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
-OR-
DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
A~D,
D FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors./ understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is avai/abf e upon request when this application is
submitted or at the following Web site: http: I /www.leginfo.ca.gov/ calaw.html.
OWNER CERTIF/CA T/ON: The applicant certifie5 that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility
easements. All proposed modifications and/or additions ore clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site pion are not approved for
construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of;
the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true
and correct; all easements and other encumbrances to development hove been accurately shown and labeled os well as oil on-site grading/site preparation. All improvements existing on the property
were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT): SIGN: DATE:
Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner.
1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov
2 REV. 04/22
Permit Type:
Work Class:
Status:
Scheduled
Date
PERMIT INSPECTION HISTORY for (CBC2022-0261)
BLDG-Commercial Application Date: 07/26/2022 Owner: OCEAN COLLECTION LLC
Tenant Improvement Issue Date: 10/26/2022 Subdivision:
Closed -Finaled Expiration Date: 09/05/2023 Address: 2510 GATEWAY RD, # 101
IVR Number: 42213 CARLSBAD, CA 92009-1727
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
Checklist Item
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
NOTES Created By
Angie Teanio
Status
COMMENTS
April 17, 2023:
Certificate of Occupancy: approved.
1. B-59 waste management recycle debris
form with receipts-approved.
2. Mechanical air balance report-approved.
3. Double Hurkulite doors
installed-approved.
4. The rest of interior tenant improvement,
scope of work per engineered plans and
detail specifications-approved.
TEXT
619-247-8119 Dirk// Pre-final walk, still has
revision hold.
Passed
Yes
Yes
Yes
Yes
Created Date
03/23/2023
Tuesday, May 2, 2023 Page 6 of 6
Permit Type:
Work Class:
Status:
Scheduled
Date
04/17/2023
PERMIT INSPECTION HISTORY for (CBC2022-0261)
BLDG-Commercial Application Date: 07/26/2022 Owner: OCEAN COLLECTION LLC
Tenant Improvement Issue Date: 10/26/2022 Subdivision:
Closed -Finaled Expiration Date: 09/05/2023 Address: 2510 GATEWAY RD, # 101
IVR Number: 42213
CARLSBAD, CA 92009-1727
Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection
Start Date
Checklist Item
BLOG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
NOTES Created By
Angie Teanio
Status
COMMENTS
March 24, 2023:
TCO (training, stocking shelves, and
installing equipment)-ONLY ..
1. Temporary certificate of occupancy
(TCO) -issued.
PENDING:
2. 8-59 waste management recycle debris
form with receipts-required.
3. Mechanical air balance report N
required.
4. Double Hurkulite doors required to be
installed.
5. The rest of interior tenant improvement,
scope of work per engineered plans and
detail specifications -OK.
6. Informed contractor representative Dirk
pertaining to corrections list remaining and
will be re-inspected and verified at final
inspection.
March 24, 2023:
TCO (training, stocking shelves, and
installing equipment)-ONLY ..
1. Temporary certificate of occupancy
(TCO) -issued.
PENDING:
2. B-59 waste management recycle debris
form with receipts-required.
3. Mechanical air balance report N
required.
4. Double Hurkulite doors required to be
installed.
5. The rest of interior tenant improvement,
scope of work per engineered plans and
detail specifications -OK.
6. Informed contractor representative Dirk
pertaining to corrections list remaining and
will be re-inspected and verified at final
inspection.
TEXT
619-247-8119 Dirk// Pre-final walk, still has
revision hold.
04/17/2023 BLDG-Final Inspection 208125-2023 Passed Tony Alvarado
Passed
Yes
Yes
Yes
Yes
Yes
Created Date
03/23/2023
Tuesday, May 2, 2023
Inspection
Complete
Page 5 of6
PERMIT INSPECTION HISTORY for (CBC2022-0261)
Permit Type: BLDG-Commercial
Work Class: Tenant Improvement
Status: Closed -Finaled
Application Date: 07/26/2022 Owner: OCEAN COLLECTION LLC
Issue Date: 10/26/2022 Subdivision:
Expiration Date: 09/05/2023
IVR Number: 42213
Address: 2510 GATEWAY RD, # 101
CARLSBAD, CA 92009-1727
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
02/21/2023
03/07/2023
03/24/2023
Checklist Item
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
NOTES Created By
Angie Teanio
COMMENTS
February 15, 2023:
1. Interior tenant improvement, bathroom
location-only, ceiling (plumbing, electrical,
and mechanical scope of work per plan)-
OK/partial pass.
2. Tenant improvement, gypsum board,
anchoring/method of attachment -partial
pass.
February 15, 2023:
1. Interior tenant improvement, bathroom
location-only, ceiling (plumbing, electrical,
and mechanical scope of work per plan)-
OK/partial pass.
2. Tenant improvement, gypsum board,
anchoring/method of attachment -partial
pass.
TEXT
619-247-8119 Dirk
02/21/2023 BLDG-82 Drywall,
Exterior Lath, Gas Test,
203908-2023 Passed Tony Alvarado
Hot Mop
Checklist Item COMMENTS
BLDG-17 Interior Lath-Drywall 1. drywall inspection for restroom ceiling
locations and the rest of interior tenant
improvement -approved.
BLDG-23 Gas-Test-Repairs
2. Gas test, under air pressure leak test -
approved.
03/07/2023 BLDG-27 Shower
Pan/Tubs
204816-2023 Passed Tony Alvarado
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Angie Teanio
COMMENTS
TEXT
619-247-8119 Dirk
03/24/2023 BLDG-Final Inspection 206221-2023 Partial Pass Tony Alvarado
Tuesday, May 2, 2023
Passed
Yes
Yes
Yes
Yes
Created Date
02/14/2023
Passed
Yes
Yes
Passed
Yes
Created Date
03/06/2023
Complete
Complete
Reinspection Incomplete
Page 4 of6
PERMIT INSPECTION HISTORY for (CBC2O22-0261)
Permit Type: BLDG-Commercial
Work Class: Tenant Improvement
Application Date: 07/26/2022
Issue Date: 10/26/2022
Owner: OCEAN COLLECTION LLC
Subdivision:
Status:
Scheduled
Date
02/15/2023
Closed -Finaled Expiration Date: 09/05/2023
IVR Number: 42213
Address: 2510 GATEWAY RD, # 101
CARLSBAD, CA 92009-1727
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLOG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
December 2, 2022: (PENDING):
1. Rough electrical, scope of work -
(partial pass).
(a) pending: fire department approval.
(b) Missing additional emergency
illuminated exit sign rough electrical conduit
and junction boxes.
2. Rough top-out plumbing-approved
previously.
3. Mechanical ducting, scope of work, per
engineered plans and detail
specifications-not ready.
4. Framing/rough framing-partial pass.
02/15/2023 BLDG-17 Interior
Lath/Drywall
203449-2023 Partial Pass Tony Alvarado
Checklist Item
BLOG-Building Deficiency
COMMENTS
February 15, 2023:
1. Interior tenant improvement, bathroom
location-only, ceiling (plumbing, electrical,
and mechanical scope of work per plan)-
OK/partial pass.
2. Tenant improvement, gypsum board,
anchoring/method of attachment -partial
pass.
BLDG-85 T-Bar, Ceiling 203336-2023 Partial Pass Tony Alvarado
Grids, Overhead
Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
No
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Tuesday, May 2, 2023 Page 3of6
PERMIT INSPECTION HISTORY for (CBC2022-0261)
Permit Type: BLDG-Commercial
Work Class: Tenant Improvement
Application Date: 07/26/2022
Issue Date: 10/26/2022
Owner: OCEAN COLLECTION LLC
Subdivision:
Status:
Scheduled
Date
12/07/2022
12/14/2022
02/01/2023
Closed -Finaled Expiration Date: 09/05/2023
IVR Number: 42213
Address: 2510 GATEWAY RD, # 101
CARLSBAD, CA 92009-1727
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
December 2, 2022: (PENDING):
1. Rough electrical, scope of work -
(partial pass).
(a) pending: fire department approval.
(b) Missing additional emergency
illuminated exit sign rough electrical conduit
and junction boxes.
2. Rough top-out plumbing-approved
previously.
3. Mechanical ducting, scope of work, per
engineered plans and detail
specifications-not ready.
4. Framing/rough framing-partial pass.
12/07/2022 BLDG-16 Insulation 198301-2022 Passed Tony Alvarado
12/14/2022 BLDG-17 Interior
Lath/Drywall
Checklist Item
198896-2022
COMMENTS
Partial Pass Tony Alvarado
BLOG-Building Deficiency December 14, 2022:
02/01/2023 BLDG-84 Rough
Combo(14,24,34.44)
1. Partial pass-(phase 1 )-exterior
loadbearing walls/existing walls, interior
tenant improvement office
space-drywall/gypsum board -partial
pass.
2. Partial Pass-new thermal energy
efficient insulation and drywall
nailing/anchoring method of attachment -
approved. (Phase 1 ).(only).
201987-2023 Cancelled Tim Kersch
Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
No
Complete
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Tuesday, May 2, 2023 Page 2 of6
Building Permit Inspection History Finaled
{_ City of
Carlsbad
Permit Type:
Work Class:
Status:
Scheduled
Date
11/04/2022
12/02/2022
PERMIT INSPECTION HISTORY for (CBC2022·0261)
BLDG-Commercial
Ten ant Improvement
Closed -Finaled
Actual Inspection Type
Start Date
11/04/2022 BLDG-21
Underground/Underflo
or Plumbing
Checklist Item
Application Date: 07/26/2022
Issue Date: 10/26/2022
Expiration Date: 09/05/2023
IVR Number: 42213
Inspection No. Inspection
Status
195964-2022 Partial Pass
COMMENTS
Owner: OCEAN COLLECTION LLC
Subdivision:
Address: 2510 GATEWAY RD, # 101
CARLSBAD, CA 92009-1727
Primary Inspector Reinspection Inspection
Tony Alvarado Reinspection Incomplete
Passed
BLDG-Building Deficiency November 4, 2022: Yes
12/02/2022 BLDG-14
Frame/Steel/Bolting!We
lding (Decks)
Checklist Item
1. Commercial interior tenant space,
underground waste and vent lines, phase
1, under water leak head pressure test
-scope of work-OK.
197852-2022 Partial Pass Tony Alvarado
COMMENTS
BLDG-Building Deficiency December 2, 2022:
BLDG-34 Rough
Electrical
Checklist Item
1. Rough electrical, scope of work -
(partial pass)-OK (a) pending: fire
department approval.
2. Missing emergency iltuminated exit sign
rough electrical conduit and junction boxes.
197851-2022 Partial Pass Tony Alvarado
COMMENTS
BLDG-Building Deficiency December 2, 2022:
BLDG-84 Rough
Combo(14,24,34,44)
1. Rough electrical, scope of work -
(partial pass)-OK (a) pending: fire
department approval.
2. Missing emergency illuminated exit sign
rough electrical conduit and junction boxes.
197927-2022 Partial Pass Tony Alvarado
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Tuesday, May 2, 2023 Page 1 of6
AIR-SOUND-HYDRONIC PROFESSIONALS
HVAC Test and Balance Report
PROJECT:
CONTRACTOR:
ARCHITECT:
ENGINEER:
Sully-T.I.
2510 Gateway Rd
Carlsbad, CA
National
L 7 Studio Architects
Plum Engineering
REPORT CERTIFICATION NO: 42033
REPORT CERTIFICATION DATE: April 3, 2023
REVIEWED AND APPROVED BY:
Michael Conboy
ICB /TABB Certified Contractor
457 E. Arrow Hwy, Ste. D, Azusa, CA 91702
TEL: 62(,-915-8117 FAX: 626 915-8112
l •> 1\:IA 11 ,: •J~.;-,_~l(tat~·~l_,_1_U_:b.~•h!!-1_r~:GW!!tH.tiLr.~1-tu
...----•~.-,._-~'" ~----..------.•~=--•-~~; -~,-.~-~,-,,~ ,..--.,,~.~•"""'-"" __ .,.._."._ "" --, •-.. -<,_...,--_ ---•-~----~·-··-----·"' -~---··.<. ---0=·-=·-----o¾•····~--~,-=--..,-'"------""'-""--
STATE OF CALIFORNIA
Ql:ontractorg ~rate ·JLtrense iioarb
Pursuant to Chapter 9 of Division 3 of the Business and Professions Code
and the Rules and Regulations of the Contractors State License Board,
the Registrar of Contractors does hereby issue this license to:
'
MICHAEL CONBOY INC cl6a ASSOCIATED AIR
BALANCE
to engage in the business or act in the capacity of a contractor
in the following classification(sl:
D62 -AIR AND WATER BALANCING
B -GENERAL BUILDING CONTRACTOR
Witness my hand and seal this day,
May 9, 2008
Issued December 21, 2004
REPLACEMENT ~!:fL
Registrar of Contractors
This i icensc is the property of the Registrar of Contractors,
is not transferrable, and shall be returned to the Registrar
upon demand when suspended, revoked, or invalidated
for an~· re:ison. It bt'comes void if not renewed.
851730
License Number
--.~-----··-"·--=--·--· ~-,,,.,,._-----~·-----~~--..,._,__ . ...,_,..,,._,, . .,.,_....,,. --=· ·-· -·-~».·· ...... ,...,_,.-.,._'"-"""T-~•--,,,.,._ -·-"•-···--~ -~-----
1 :!L ~-l REV l :i-r.·-~ OSF Ll/ :::04W
AU[llT "'0 441)746
i _l
.,
TB0945108C
Certification#
12/8/2022
Certification Date
12/31/2024
Valid Through
.
I :
INTER-CERTlFICATION BOARD
The Sheet Metal Industry
International Certification &Jard
Certifies that
assodated air balance
Has successfully completed the requirements for
TABB Contractor
i•
--,, .......
--="4./~.~
Labor Co-Chairperson
• • ~ ·~ "S:---Managernent Co.Chairperson
L,.JL~
ICBffABB Administrator
l Pi
-~--_:, ____ ::::.._ (&
,_I, .;:··~ f7,r&··.,,. C ' . ' ...., L~, ,. 1/.b,,,'f
• , I • ' \ ,._ 4 h c ,?J .... '!.i~;,_1,:::1
INTERNATIONAL TESTING,, AOJUSTING AND 8Al.ANCING BUREAU
CERTIACATION BOARD' .t THE -PROFESSIONAL'S CHOICE-
TB6101708S
Certification#
1/20/2023
The Sheet Metal Industry
International Certification Board
Certifies that
Michael A Conboy
Has successfully completed the requirements for
TABB Supervisor
r
:. (,-
~ , • J./ -/ ,"\/\ __ ',~ ---
\",..;._r. ,~~=:l . .... . , ' '~ _,
Labor Co-Chairperson
'
Certification Date ---->,;: "''" .. ,,_ , ... ~, .... ,_ \{ttq4 f ~ -------Management Co-Chairperson
12/31/2024 __ _______ii.__.___:, L-~...:..._ .... _ ..__ ·-·· -
Valid Through ICB!T ABB Admmistrator
' I : -CERTIFICATION BOARD
TB1044482S
Ci:nification #
5/13/2022
Certification Date
12/31/2024
Valid Through
TESTING. ADJUS11NG AND BAl.ANCING BURE
TNE PROfESSIONAL'S CHOICE-
#0728
150/IEC 17024
Personnel Certification Program
The Sheet Metal Industry
International Certification Board
Certifies that
William James Scrimmager Jr
Has successfully completed the requirements for
TABB Supervisor
'• ,,,·
---,4~
Labor Co-Chairman . .
kttwiJ~ ~-
:Management Co-Chairman
,, ' :-:::.·:
·· . ..:::-
:::r::a .. JL ~·
ICBrr ABB Administrator
ACT
VAV
AK
w
ATC
WB
BP
WG
CAV
DP
CD
DT
CE
CFM
CF
CL
CR
DB
DD
DNL
EMS
ENT
ESP
457 I<:, Arrow Hwy., Suite D., Azusa, CA 91723
Tel: (626) 915-8117 Fax: (626) 915-8112
Email: a,sociatedairhalance@gmail.com
ABBREVIATl_9NS
-Actual FH •Flow Hood (Measures CFM Dlrectly, FPM and AK
-Variable Air Volume Box Factors Not Required)
-Free Area Factor FPM -Feet Per Minute
-Watts FPVAV -Fan Powered Variable Air Volume Box
-Automatic Temperature Control GPM -Gallons per Minute
-Wet Bulb HP -Horsepower
-Bypass (Damper, Value, ETC) KW -Kilowatts
-Water Gauge L/S -Liters Per Second
-Constant Air Volume Box MB -Mixing Box
-Differential Pressure NA -Not Applicable/ Access
-Ceiling Diffuser NM -Not Measured
-Differential Temperature NVL -No Valid location
-Celling Exhaust Diffuser OSA -Outside Air
-Cubic Feet Per Minute PD -Pressure Drop
-Coefficient Factor RA -Return Air
-Center Line REQ -Required
-Ceiling Return Inlet RPM -Revolutions per Minute
-Dry Bulb SA -Supply Air
~Direct Drive SFD -Smoke Fire Damper
-Data Not Listed SP -Static Pressure
-Emergency Management System SWR -Sidewall Return
-Entering sws -Side Wall supply
-External Static Pressure TDH -Total Dead Head
TP -Thermal protected
SULLY -2510 GATEWAY RD. CARLSBAD
Table of Contents
System
HP-1, HP-2 Fan Test
HP-1 Diffuser_Sheet
HP-2 Diffuser _Sheet
HP-3, HP-4 Fan Test
HP-3 Diffuser _Sheet
HP-4 Diffuser _Sheet
HP-5 Fan Test
HP-5 Diffuser _Sheet
EF-1,EF-2,EF-5 Diffuser_Sheet
Page Number
1
2
3
4
5
6
7
8
9
U.:l+U:lL
Fan Test Data
Job Name: SULLY 2510 GATEWAY RD. CARLSBAD
System: (E) HP-1, HP-2
UNIT INFORMATION
Unil Number (E) HP-1
Location ROOF
Area Served STUDIO 111
Manufacturer PAYNE
Model Number PH3GPAA36000AA--
Serial Number 3111C06556
AIR MEASUREMENTS
Total Fan CFM 2,000 2,023
Total Outlet CFM 2,000 2,023
Total Return CFM 1,855 1,871
Total OSA CFM 145 152
External Fan Static Pressure 0.50" 048"
Suction Static Pressure -0.28"
Discharge Static Pressure 0.20''
Fan RPM HIGH/MED/LOW HIGH SPEED
MOTOR MEASUREMENTS Design Actual
Motor Manufacturer GENTEQ
Motor HP 0.75
Motor Frame N/S 48Y
Motor Voltage -Leg1/Leg2/Leg3 208 208
Motor Phase 1 1
Motor Amperage -Leg1/Leg2/Leg3 6.0 4.4
Motor Service Factor N/S TP
Motor RPM N/S N/S
VFD Hz. Setting N/A N/A
PULLEY & BELT DATA
Motor Pulley DIRECT DRIVE
Fan Pulley DIRECT DRIVE
Belt -Quantity/Size DIRECT DRIVE
Center Distance DIRECT DRIVE
% Sheave Adjusted Closed DIRECT DRIVE
Motor Travel In/Out DIRECT DRIVE
Remarks:
Page 1
Date: 4/3/2023
Technician: M.C
(E) HP-2
ROOF
LOUNGE 100, CONTROL 101
PAYNE
PH3GPAA36000AA--
3111C06558
1,200 1,170
1,195 1,170
985 950
210 220
0.50" 047"
-0.28"
-0.19"
HIGH/MED/LOW HIGH SPEED
Design Actual
GENTEQ
0.75
N/S 48Y
208 208
1 1
6.0 4.1
N/S TP
N/S N/S
NIA N/A
DIRECT DRIVE
DIRECT DRIVE
DIRECT DRIVE
DIRECT DRIVE
DIRECT DRIVE
DIRECT DRIVE
Diffuser And Grille Test Data
Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA
System: (E) HP-1
Room Number Size Type Ak
Ht-'-1
S/A
111 1 S300FS sws 1.00
111 2 S300FS sws 1.00
111 3 S300FS sws 1.00
111 4 S300FS sws 1.00
111 5 S300FS sws 1.00
111 6 S300FS sws 1.00
TOTAL
HP-1
R/A
107 R-1 18" DUCT 1.76
HP-1
OSA
UNIT 1 1 O"X10" HOOD 0.69
Remarks:
Date: 4/3/2023
Technician: M.C.
Design Actual
FPM CFM FPM CFM
-400 -412
-400 -415
-300 -289
-300 -285
-300 -312
-300 -310
2,000 2,023
1054 1,855 1063 1,871
210 145 220 152
U::>-,..U.JL
Diffuser And Grille Test Data
Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA
System: (E) HP-2
Room Number Size Type Ak
nr--L
SIA
102 1 S300FS SWS 1.00
102 2 S300FS sws 1.00
100 3 S300FS sws 1.00
100 4 S300FS sws 1.00
100 5 S300FS sws 1.00
101 6 12" RD 1.00
TOTAL
HP-2
R/A
WALKWAY R-1 14" DUCT 1.00
OFFICW 102 R-2 12"X6" SWR 1.00
TOTAL
HP-2
OSA
UNIT 1 1 O"x1 O" HOOD 0.69
Remarks:
Date: 4/3/2023
Technician: M.C.
Design Actual
FPM CFM FPM CFM
-50 -55
-50 -50
-115 -120
-115 -118
-115 -115
-750 -712
1,195 -1,170
-915 -875
-70 -75
985 950
304 210 319 220
U.:HU.:SL
Fan Test Data
Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA
System: (E) HP-3, HP-4
UNIT INFORMATION
Unit Number (E) HP-3
Location ROOF
Area Served 105, STUDIO B 107
Manufacturer PAYNE
Model Number PH3GPAA36000AA--
Serial Number 3211C32312
AIR MEASUREMENTS
Total Fan CFM 1,050 1,058
Total Outlet CFM 1,050 1,058
Total Return CFM 960 963
Total OSA CFM 90 95
External Fan Static Pressure 0.50" 0.53"
Suction Static Pressure 0.33"
Discharge Static Pressure -0.20''
Fan RPM HIGH/MED/LOW HIGH SPEED
MOTOR MEASUREMENTS Design Actual
Motor Manufacturer GENTEQ
Motor HP 0.75
Motor Frame NIS 48Y
Motor Voltage -Leg 1 /Leg2/Leg3 208 208
Motor Phase 1 1
Motor Amperage -Leg 1 /Leg2/Leg3 6.0 4.8
Motor Service Factor N/S T.P
Motor RPM NIS N/S
VFD Hz. Setting NIA N/A
PULLEY & BELT DATA
Motor Pulley DIRECT DRIVE
Fan Pulley DIRECT DRIVE
Belt -Quantity/Size DIRECT DRIVE
Center Distance DIRECT DRIVE
% Sheave Adjusted Closed DIRECT DRIVE
Motor Travel In/Out DIRECT DRIVE
Remarks:
Page 4
Date: 4/3/2023
Technician: M.C.
(E) HP-4
ROOF
STUDIO B, 107
PAYNE
PH3GPAA36000AA--
3211C32343
1,980 1,989
1,980 1,989
1,830 1,832
150 157
0.50" 0.50"
-0.31"
0.19"
HIGH/MEO/LOW HIGH SPEED
Design Actual
GENTEQ
1
NIS 48Y
208 208
1 1
7.6 5.5
N/S TP
N/S N/S
N/A N/A
DIRECT DRIVE
DIRECT DRIVE
DIRECT DRIVE
DIRECT DRIVE
DIRECT DRIVE
DIRECT DRIVE
Ucl+U::SL
Diffuser And Grille Test Data
Job Name: SULLY 2510 GATEWAY RD CARLSBAD, CA
System: (E) HP-3
Room Number Size Type Ak
HP-3
SIA
105 1 S300FS sws 1.00
105 2 S300FS sws 1.00
107 3 S300FS sws 1.00
107 4 S300FS sws 1.00
TOTAL
HP-3
R/A
WALKWAY R-1 24"X12" SWR 1.00
HP-3
OSA
UNIT 1 1 O"x1 O" HOOD 0.69
Remarks:
Date: 4/3/2023
Technician: M.C.
Design Actual
FPM CFM FPM CFM
-320 -305
-320 -336
-205 -216
-205 -200
1,050 1,058
-960 -963
130 90 138 95
Diffuser And Grille Test Data
Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA
System: (E) HP-4
Room Number Size Type Ak
HP-4
SIA
109 1 S300FS sws 1.00
109 2 S300FS SWS 1.00
107 3 S300FS SWS 1.00
107 4 S300FS SWS 1.00
107 5 S300FS SWS 1.00
107 6 S300FS SWS 1.00
107 7 S300FS SWS 1.00
107 8 S300FS SWS 1.00
TOTAL
HP-4
RIA
WALKWAY R-1 36"X12" $WR 1.00
HP-4
OSA
UNIT 1 1 0"x1 0" HOOD 0.69
Remarks:
Date: 4/3/2023
Technician: M.C.
Desian Actual
FPM CFM FPM CFM
-150 -155
-150 -150
-280 -290
-280 -294
-280 -266
-280 -276
-280 -278
-280 -280
1,980 1,989
-1,830 -1,832
217 150 227 157
Page b
03+032
Fan Test Data
Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA
System: (E) HP-5
UNIT INFORMATION
Unit Number (E) HP-5
Location ROOF
Area Served STUDIO A, 111
Manufacturer PAYNE
Model Number PH3GPAA36000AA--
Serial Number 2911C05886
AIR MEASUREMENTS
Total Fan CFM 1,200 1,190
Total Outlet CFM 1,200 1,190
Total Return CFM 1,090 1,080
Total OSA CFM 110 110
External Fan Static Pressure 0.50" 0.54"
Suction Static Pressure 0.35"
Discharge Static Pressure 0.19"
Fan RPM HIGH/MED/LOW HIGH SPEED
MOTOR MEASUREMENTS Design I Actual
Motor Manufacturer GENTEQ
Motor HP NIS 0.75
Motor Frame N/S 48Y
Motor Voltage -Leg1/Leg2/Leg3 208 208
Motor Phase 1 1
Motor Amperage -Leg1/Leg2/Leg3 6.0 5 1
Motor Service Factor NIS T.P.
Motor RPM NIS N/S
VFD Hz. Setting NIA NIA
PULLEY & BELT DATA
Motor Pulley DIRECT DRIVE
Fan Pulley DIRECT DRIVE
Belt -Quantity/Size DIRECT DRIVE
Center Distance DIRECT DRIVE
% Sheave Adjusted Closed DIRECT DRIVE
Motor Travel In/Out DIRECT DRIVE
Remarks:
Page 7
Date: 4/312023
Technician: M.C.
Design Actual
U3+U:lZ
Diffuser And Grille Test Data
Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA
System: (E) HP-5
Room Number Size Type Ak
Ht'-4
SIA
111 1 S300FS SWS 1.00
111 2 S300FS SWS 1.00
111 3 S300FS SWS 100
111 4 S300FS SWS 100
111 5 S300FS SWS 100
111 6 S300FS SWS 1.00
TOTAL
HP-5
RIA
111 R-1 1611 DUCT 1.40
HP-5
OSA
UNIT 1 1 O"x1 O" HOOD 0.69
Remarks:
Date: 41312023
Technician: M.C.
Design Actual
FPM CFM FPM CFM
-200 -210
-200 -190
-200 -190
-200 -195
-200 -205
-200 -200
1,200 1,190
779 1,090 771 1,080
159 110 159 110
Page 8
U:S+U:SL
Diffuser And Grille Test Data
Job Name: SULLY 2510 GATEWAY RD CARLSBAD, CA
System: (E) EF-1, EF-2, EF-5
Room Number Size Type Ak
tcr--1
E/A
RR 103 1 12"X10" EG 1.00
EF-2
E/A
RR 104 1 12"X10" EG 1.00
EF-5
E/A
RR 1 12"X10" EG 1.00
Date: 4/3/2023
Technician: M.C.
Design Actual
FPM CFM FPM CFM
-150 -150
-150 -155
. N/S . 150
Remarks: CEILING MOUNTED EXHAUST FANS NO FAN TEST SHEET REQUIRED
Page~
SAN DIEGO REGIONAL
HAZARDOUS MATERIALS
QUESTIONNAIRE
OFFICE USE ONLY
RECORD ID # ___________________ 1 PLAN CHECK # __________________
1
BP DATE
Business Name
SULLY ASSET GROUP, LLC
Project Address
2510 GATEWAY ROAD
Mailing Address
2510 GATEWAY ROAD
Project Contact
JOHN LETTER
usiness Contact
OBERT SULLIVAN
State
CA
Telephone#
858,353-0945
Ztp Code
92009
APN#
213-261-15-00
City State Zip Code Plan File# <:;f \JBAD CA 92009
A 'li\'\<'11 E-mail Telephone #
, :vClhlNLETTER@L7STUDIOARCHITECTS.COM 858.952.8166
Tho foflo · tjuest{9fi,S,r8present the facility's activities, NOT the specific project description.
PART I: FIRE DEPARTMEN -H~ 'M .TERIALS DIVISION: OCCUPANC CLA SIFICATION: not re uired for ro·ects within th Cit I San
Ole o : Indicate by circling the item, & er your business will use, process, or store any o the folfowIng hazardous materials If any of the items are circled,
applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittaL
Occupancy Rating: Facility's Square Footage {including proposed project):
1. Explosive or Blasting Agents 5. Organic Peroxides g_ Water Reacflves 13. Corrosives
2. Compressed Gases 6, Oxidizers 10. Cryogenics 14. Other Health Hazards
3. Flammable/Combustible Liquids 7. Pyrophorics 11 Highly Toxic or Toxic Materfals 15. None of These.
4. Flammable Solids 8 Unstable Reactives 12. Radloactives
PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION /HMO!: If lhe answer to any of lhe
questions is yes, applicant must contact !he County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123.
Call (858) 505~6700 prior to the issuance of a building pem,it
FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 0 CaJARP Exempt
I
1.
2.
3.
4
5.
6.
7.
8.
YES NO (for new construction or remodeling projects)
Is your business listed on the reverse side of this form? (check all that apply). D ll9 D 119 Will your business dispose of Hazardous Substances or Medical Waste in any amount?
D [lg Will your business store or handle Hazardous Substances In quantities greater than or equal to 55 gallons, 500
pounds and/or 200 cubic feet?
D
D D D D
~ Will your business store or handle carcinogens/reproductive toxins in any quantity?
@ Will your business use an existing or install an underground storage tank?
~ Will your business store or handle Regulated Substances (CalARP)? IZI Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? ~ WIii your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to
or reater than 1,320 allons? California's Above round Petroleum Stora e Act .
Date Initials
0 CalARP Required
I
Dale Initials
0 CalARP Complete
I
Date lnltials
PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT APCD : Any YES~ answer requires a stamp from APCD 10124 Old Grove Road, San
Dlego, C 92131 apcdcomp@sdcounty.ca.gov (858 586~2650 . {"No stamp required if Q1 Yes mill Q3 Yes~ 04-06 No]. The following questions are intended
to Identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive
requirements contact APCD. Residences are typically exempt, except -those with more than one building• on the property; single buildings with more than four
dwelling units; townhomes; condos; mixed~commercial use; deliberate burns; residences forming part of a larger project. rExcludes garages & small outbuildings.]
1.
2.
3.
4.
5.
6.
YES NO
00 D
D IX! D Qil
D
D
[lg
~
Will the project disturb 160 square feet or more of existing building materials?
Will any load supporting structural members be removed? Notification may be required 1 O working days prior to commencing demolition.
(ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance
Technician?
(ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification
may be required 10 working days prior to commencing asbestos removal-
Will the project or associated construction equipment emit afr contaminants? See the reverse side of this fom, or APCD factsheel
(www.sdapgd.org/info/facls/pennits.pdf) for typical equipment requiring an APCD permit.
D ~ (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school
bounda
activities: Briefly describe proposed project:
TENANT IMPROVEMENT FITNE NTER
I declare under penalty of perjury that to the best of my knowledge and bpli';'f t ,,,_ responses made herein are true and correct.
JOHN J LETTER ' 01 J 21 / 2022
Name of Owner or Authorized Agent SiQnature of Owner or Authorized Agent Date
FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _______________________________ _
BY· DATE· I I
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY
COUNTY-HMO~ APCD COUNTY-HMO APCD COUNTY-HMO APCD
';)\,\on if-" C Reviewed 0
ii 10/24/2022 TW :1:
0Me/1nitiafs
..r ~// ,f co"
*A stamp In this box .Q!!h! exempts busrnesses from completing or updating a Hazardous Matenals Business Plan. Other perm1ttmg requirements may still apply.
HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division
Building Permit Finaled
Revision Permit
Print Date: 05/02/2023
Job Address:
Permit No:
Status:
( City of
Carlsbad
PREV2023-0011
Closed -Finaled
Permit Type:
2510 GATEWAY RD, # 101,
BLDG-Permit Revision
CARLSBAD, CA 92009-1727
Work Class: Commercial Permit Revision
Parcel#: 2132611513
Valuation: $0.00
Occupancy Group: B
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition: 2019
Sprinkled: Yes
Project Title:
Track#:
Lot#:
Project#:
Plan#:
Construction Type:V-B
Orig. Plan Check#: CBC2022-0261
Plan Check#:
Description: SULLY OFFICE COM-Tl: REVISIONS TO MECH,ELEC,PLUM/PARTITIONS
Applicant:
L7 STUDIO ARCHITECTS
JOHN LETTER
5190 GOVERNOR DR, # 204
SAN DIEGO, CA 92122-2847
(858) 952-8166
FEE
BUILDING PLAN CHECK FEE (manual)
Total Fees: $300.00
Building Division
Total Payments To Date: $300.00
Applied: 02/02/2023
Issued: 04/18/2023
Finaled Close Out: 05/02/2023
Final Inspection:
INSPECTOR:
Contractor:
VILLAGE PROPERTY SYSTEMS INC
4920 CARROLL CANYON RD, # STE 200
SAN DIEGO, CA 92121-3735
(858) 755-1800
Balance Due:
AMOUNT
$300.00
$0.00
Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
{'city of
Carlsbad
PLAN CHECK REVISION OR
DEFERRED SUBMITTAL
APPLICATION
8-15
Development Services
Building Division
1635 Faraday Avenue
442-339-2719
www.carlsbadca.gov
No: CBC2022-026 I ,{1/J .c"\ , ., ""3 ,-,,,, I I Original Plan Check Number ________ Plan Revision Number'fl'<,,ev u-,,~ -CJ./
Project Address 25 IO GATEWAY ROAD, CARLSBAD, CA 92009
General Scope of Revision/Deferred Submittal: REVISIONS TO NON-BEARING PARTITIONS
ASSOCIATED REVISIONS TO MECHANICAL, ELECTRICAL, AND PLUMBING
CONTACT INFORMATION:
Name JOHN LETTER Phone 858.952.8 I 66 ________ Fa"----------~ Ad-ttzo~ GOVERNOR DRIVE, SUITE 204 City SAN DIEGO 92122 Zip ____ _
E .1 Add JOHNLETTER@L7STUDIOARCHITECTS.COM ma, ress -------------------------------
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised: Ii] Plans O Calculations O Soils O Energy O Other
2. 3.
Describe revisions in detail List page(s) where each
revision is shown
SEE ATTACHED DOCUMENT
4. Does this revision, in any way, alter the exterior of the project? 0 Yes Ii] No
5. Does this revision add ANY new floor area(s)? 0 Yes O No
6. Does this revision affect any fire related issues? 0 Yes Ii] No
7. Is this a completeFse? Ii] Yes O No
02.02.2023
~Signature __ +---+----------------Date
1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 442-339-2719 f;!/1: 760-602-8558 Email:
building@carlsbadca.govwww.carlsbadca.gov