Loading...
HomeMy WebLinkAbout2510 GATEWAY RD; 101; CBC2022-0261; PermitBuilding Permit Finaled (city of Carlsbad Commercial Permit Print Date: 05/02/2023 Job Address: 2510 GATEWAY RD, # 101, CARLSBAD, CA 92009-1727 Permit No: Status: CBC2022-0261 Closed -Finaled Permit Type: BLDG-Commercial 2132611513 $300,189.12 Work Class: Tenant Improvement Parcel#: Valuation: Occupancy Group: B #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: 2019 Sprinkled: Yes Project Title: Track#: Lot#: Project#: Plan#: Construction Type:V-B Orig. Plan Check #: Plan Check#: Description: SULLY OFFICE COM-Tl: (5,208 SF) NON-STRUCTURAL Applicant: L7 STUDIO ARCHITECTS JOHN LETTER 5190 GOVERNOR DR, # 204 SAN DIEGO, CA 92122-2847 (858) 952-8166 FEE BUILDING PLAN CHECK BUILDING PLAN REVIEW-MINOR PROJECTS (LDE) BUILDING PLAN REVIEW -MINOR PROJECTS (PLN) CERTIFICATE OF OCCUPANCY COMM/IND Tl -NON-STRUCTURAL SB1473 -GREEN BUILDING STATE STANDARDS FEE SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION -COMMERCIAL (SMIP) TRAFFIC IMPACT Commercial-Industrial w/in CFD Total Fees: $8,312.31 Total Payments To Date: $8,312.31 Applied: 07/26/2022 Issued: 10/26/2022 Finaled Close Out: 05/02/2023 Final Inspection: 04/17/2023 INSPECTOR: Kersch, Tim Alvarado, Tony Contractor: VILLAGE PROPERTY SYSTEMS INC 4920 CARROLL CANYON RD, # STE 200 SAN DIEGO, CA 92121-3735 (858) 755-1800 Balance Due: AMOUNT $1,005.26 $194.00 $98.00 $16.00 $1,664.56 $13.00 $1,675.44 $84.05 $3,562.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov {'city of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Check Est. Value PC Deposit Date No: CBC2022-0261 $300,189.12 $1,005.26 07.26.2022 Job Address 2510 GATEWAY ROAD Tenant Name#: SULLY ASSET GROUP, LLC Suite: APN: 213-261-15-00 _____ , Lot #:, ____ Year Built: _2_0_0_8 _______ _ Year Built: 2008 Occupancy:_B __ Construction Type: VB Fire sprinklers:QYESONO A/C:(:)YESONO BRIEF DESCRIPTION OF WORK: 5,208 SF TENANT IMPROVEMENT. NO NEW AREA. MECH, ELECTRICAL, PLUMBING, 0 Addition/New: ____________ New SF and Use, __________ New SF and Use ______ SF Deck, SF Patio Cover, SF Other (Specify) ___ _ liJTenant Improvement: 5,208 SF, _____ SF, Existing Use: VACANT Proposed Use: OFFICE --------------Existing Use: Proposed Use: ______ _ D Other:----------------------------------- PRIMARY APPLICANT Name: JOHN LETTER L7 STUDIO ARCHITECTS Address: 5190 GOVERNOR DRIVE, SUITE 204 City: SAN DIEGO State: CA Zip: 92122 Phone: 858.952.8166 Email: JOHNLETER@L7STUDIOARCHITECTS.COM DESIGN PROFESSIONAL Name: JOHN LETTER (L7 STUDIO ARCHITECTS) Address: 5190 GOVERNOR DRIVE, SUITE 204 City: SAN DIEGO Phone: 858.952.8166 State:_C_A_~Zip: 92122 Email: JOHNLETTER@L?STUDIOARCHITECTS.COM PROPERTY OWNER Name: SULLY ASSET GROUP, LLC Address: 2510 GATEWAY ROAD City: CARLSBAD State: CA Zip: 92009 Phone: 858.353.0945 Email: SULLY@SULLYENTGROUP.COM CONTRACTOR OF RECORD Business Name: Burger Construction, Inc. Address: 4920 Carroll Canyon Road Suite #200 City: San Diego State:CA Zip:_9_2_1_2_1 __ _ Phone: (858) 245-3498 . bschoepp@burgercon.com Ema1l: ___ ....,.,.,,,.,,,..,..,-------------- Architect State License: _c_3_3_74_6 _________ CSLB License #:. _______ Class:-"B'-------- Carlsbad Business License# (Required): BLOS 1204028 APPLICANT CERT/FICA T/ON: I certify that I have read the applicatianandstate that the above information is correct and that the information on the plans is accurate. /agree to comply with all City ordinances and State laws relating to building construction. NAME (PRINT): JOHN LETTER ~ 07/21/2022 SIGN: -+-,"'---------DATE:------- 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov REV. 04/22 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. {OPTION A): LICENSED CONTRACTOR DECLARATION: lherebyaffirmunderpenaltyofperjurythatlamlicensedunderprovisionsofChapter9/commencingwithSection7000/ofDivision3 of the Business and Professions Code, and my license is in fu// force and effect. I also affirm under penalty of perjury one of the fo//owing declarations /CHOOSE ONE/: DI have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. PolicyNo. -OR- IX} I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for t'A,_performance <:the wo~ for w~c~this '<Jrmit is issued. My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name: merlC8n 8S. 0. 0 88 1ng Policy No. 701565471 Expiration Date: 10/1/2023 -OR-D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued {Sec. 3097 (i) Civil Code). Lender's Name: Lender's Address: CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site pion. Any potentially existing detai1 within these plans inconsistent with the site plan ore not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roods/easements, and utilities. The existing and proposed use of each building os stated is true and correct; a// easements and other encumbrances to development have been accurately shown and labeled as well as all on·site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted, NAME (PRINT): Billy Schoepp SIGNATURE: Di;,..,.,,,.,,;s,• .. ,sc,o,o, Billy Schoeppu~:"~~"~:.s;.:::::~i'.',',;;_':;,:;, ;,,,_,~11<>2'"""°"""''""" DATE: 10/6/2022 Note: If the person signing above is an authorized agent for the contractor provide a letter of authorization on contractor letterhead . • • {OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR- DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: A~D, D FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors./ understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is avai/abf e upon request when this application is submitted or at the following Web site: http: I /www.leginfo.ca.gov/ calaw.html. OWNER CERTIF/CA T/ON: The applicant certifie5 that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions ore clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site pion are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development hove been accurately shown and labeled os well as oil on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. NAME (PRINT): SIGN: DATE: Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov 2 REV. 04/22 Permit Type: Work Class: Status: Scheduled Date PERMIT INSPECTION HISTORY for (CBC2022-0261) BLDG-Commercial Application Date: 07/26/2022 Owner: OCEAN COLLECTION LLC Tenant Improvement Issue Date: 10/26/2022 Subdivision: Closed -Finaled Expiration Date: 09/05/2023 Address: 2510 GATEWAY RD, # 101 IVR Number: 42213 CARLSBAD, CA 92009-1727 Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final NOTES Created By Angie Teanio Status COMMENTS April 17, 2023: Certificate of Occupancy: approved. 1. B-59 waste management recycle debris form with receipts-approved. 2. Mechanical air balance report-approved. 3. Double Hurkulite doors installed-approved. 4. The rest of interior tenant improvement, scope of work per engineered plans and detail specifications-approved. TEXT 619-247-8119 Dirk// Pre-final walk, still has revision hold. Passed Yes Yes Yes Yes Created Date 03/23/2023 Tuesday, May 2, 2023 Page 6 of 6 Permit Type: Work Class: Status: Scheduled Date 04/17/2023 PERMIT INSPECTION HISTORY for (CBC2022-0261) BLDG-Commercial Application Date: 07/26/2022 Owner: OCEAN COLLECTION LLC Tenant Improvement Issue Date: 10/26/2022 Subdivision: Closed -Finaled Expiration Date: 09/05/2023 Address: 2510 GATEWAY RD, # 101 IVR Number: 42213 CARLSBAD, CA 92009-1727 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Start Date Checklist Item BLOG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final NOTES Created By Angie Teanio Status COMMENTS March 24, 2023: TCO (training, stocking shelves, and installing equipment)-ONLY .. 1. Temporary certificate of occupancy (TCO) -issued. PENDING: 2. 8-59 waste management recycle debris form with receipts-required. 3. Mechanical air balance report N required. 4. Double Hurkulite doors required to be installed. 5. The rest of interior tenant improvement, scope of work per engineered plans and detail specifications -OK. 6. Informed contractor representative Dirk pertaining to corrections list remaining and will be re-inspected and verified at final inspection. March 24, 2023: TCO (training, stocking shelves, and installing equipment)-ONLY .. 1. Temporary certificate of occupancy (TCO) -issued. PENDING: 2. B-59 waste management recycle debris form with receipts-required. 3. Mechanical air balance report N required. 4. Double Hurkulite doors required to be installed. 5. The rest of interior tenant improvement, scope of work per engineered plans and detail specifications -OK. 6. Informed contractor representative Dirk pertaining to corrections list remaining and will be re-inspected and verified at final inspection. TEXT 619-247-8119 Dirk// Pre-final walk, still has revision hold. 04/17/2023 BLDG-Final Inspection 208125-2023 Passed Tony Alvarado Passed Yes Yes Yes Yes Yes Created Date 03/23/2023 Tuesday, May 2, 2023 Inspection Complete Page 5 of6 PERMIT INSPECTION HISTORY for (CBC2022-0261) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed -Finaled Application Date: 07/26/2022 Owner: OCEAN COLLECTION LLC Issue Date: 10/26/2022 Subdivision: Expiration Date: 09/05/2023 IVR Number: 42213 Address: 2510 GATEWAY RD, # 101 CARLSBAD, CA 92009-1727 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 02/21/2023 03/07/2023 03/24/2023 Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers NOTES Created By Angie Teanio COMMENTS February 15, 2023: 1. Interior tenant improvement, bathroom location-only, ceiling (plumbing, electrical, and mechanical scope of work per plan)- OK/partial pass. 2. Tenant improvement, gypsum board, anchoring/method of attachment -partial pass. February 15, 2023: 1. Interior tenant improvement, bathroom location-only, ceiling (plumbing, electrical, and mechanical scope of work per plan)- OK/partial pass. 2. Tenant improvement, gypsum board, anchoring/method of attachment -partial pass. TEXT 619-247-8119 Dirk 02/21/2023 BLDG-82 Drywall, Exterior Lath, Gas Test, 203908-2023 Passed Tony Alvarado Hot Mop Checklist Item COMMENTS BLDG-17 Interior Lath-Drywall 1. drywall inspection for restroom ceiling locations and the rest of interior tenant improvement -approved. BLDG-23 Gas-Test-Repairs 2. Gas test, under air pressure leak test - approved. 03/07/2023 BLDG-27 Shower Pan/Tubs 204816-2023 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency NOTES Created By Angie Teanio COMMENTS TEXT 619-247-8119 Dirk 03/24/2023 BLDG-Final Inspection 206221-2023 Partial Pass Tony Alvarado Tuesday, May 2, 2023 Passed Yes Yes Yes Yes Created Date 02/14/2023 Passed Yes Yes Passed Yes Created Date 03/06/2023 Complete Complete Reinspection Incomplete Page 4 of6 PERMIT INSPECTION HISTORY for (CBC2O22-0261) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Application Date: 07/26/2022 Issue Date: 10/26/2022 Owner: OCEAN COLLECTION LLC Subdivision: Status: Scheduled Date 02/15/2023 Closed -Finaled Expiration Date: 09/05/2023 IVR Number: 42213 Address: 2510 GATEWAY RD, # 101 CARLSBAD, CA 92009-1727 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLOG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS December 2, 2022: (PENDING): 1. Rough electrical, scope of work - (partial pass). (a) pending: fire department approval. (b) Missing additional emergency illuminated exit sign rough electrical conduit and junction boxes. 2. Rough top-out plumbing-approved previously. 3. Mechanical ducting, scope of work, per engineered plans and detail specifications-not ready. 4. Framing/rough framing-partial pass. 02/15/2023 BLDG-17 Interior Lath/Drywall 203449-2023 Partial Pass Tony Alvarado Checklist Item BLOG-Building Deficiency COMMENTS February 15, 2023: 1. Interior tenant improvement, bathroom location-only, ceiling (plumbing, electrical, and mechanical scope of work per plan)- OK/partial pass. 2. Tenant improvement, gypsum board, anchoring/method of attachment -partial pass. BLDG-85 T-Bar, Ceiling 203336-2023 Partial Pass Tony Alvarado Grids, Overhead Reinspection Inspection Passed Yes Yes Yes Yes No Reinspection Incomplete Passed Yes Reinspection Incomplete Tuesday, May 2, 2023 Page 3of6 PERMIT INSPECTION HISTORY for (CBC2022-0261) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Application Date: 07/26/2022 Issue Date: 10/26/2022 Owner: OCEAN COLLECTION LLC Subdivision: Status: Scheduled Date 12/07/2022 12/14/2022 02/01/2023 Closed -Finaled Expiration Date: 09/05/2023 IVR Number: 42213 Address: 2510 GATEWAY RD, # 101 CARLSBAD, CA 92009-1727 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS December 2, 2022: (PENDING): 1. Rough electrical, scope of work - (partial pass). (a) pending: fire department approval. (b) Missing additional emergency illuminated exit sign rough electrical conduit and junction boxes. 2. Rough top-out plumbing-approved previously. 3. Mechanical ducting, scope of work, per engineered plans and detail specifications-not ready. 4. Framing/rough framing-partial pass. 12/07/2022 BLDG-16 Insulation 198301-2022 Passed Tony Alvarado 12/14/2022 BLDG-17 Interior Lath/Drywall Checklist Item 198896-2022 COMMENTS Partial Pass Tony Alvarado BLOG-Building Deficiency December 14, 2022: 02/01/2023 BLDG-84 Rough Combo(14,24,34.44) 1. Partial pass-(phase 1 )-exterior loadbearing walls/existing walls, interior tenant improvement office space-drywall/gypsum board -partial pass. 2. Partial Pass-new thermal energy efficient insulation and drywall nailing/anchoring method of attachment - approved. (Phase 1 ).(only). 201987-2023 Cancelled Tim Kersch Reinspection Inspection Passed Yes Yes Yes Yes No Complete Reinspection Incomplete Passed Yes Reinspection Incomplete Tuesday, May 2, 2023 Page 2 of6 Building Permit Inspection History Finaled {_ City of Carlsbad Permit Type: Work Class: Status: Scheduled Date 11/04/2022 12/02/2022 PERMIT INSPECTION HISTORY for (CBC2022·0261) BLDG-Commercial Ten ant Improvement Closed -Finaled Actual Inspection Type Start Date 11/04/2022 BLDG-21 Underground/Underflo or Plumbing Checklist Item Application Date: 07/26/2022 Issue Date: 10/26/2022 Expiration Date: 09/05/2023 IVR Number: 42213 Inspection No. Inspection Status 195964-2022 Partial Pass COMMENTS Owner: OCEAN COLLECTION LLC Subdivision: Address: 2510 GATEWAY RD, # 101 CARLSBAD, CA 92009-1727 Primary Inspector Reinspection Inspection Tony Alvarado Reinspection Incomplete Passed BLDG-Building Deficiency November 4, 2022: Yes 12/02/2022 BLDG-14 Frame/Steel/Bolting!We lding (Decks) Checklist Item 1. Commercial interior tenant space, underground waste and vent lines, phase 1, under water leak head pressure test -scope of work-OK. 197852-2022 Partial Pass Tony Alvarado COMMENTS BLDG-Building Deficiency December 2, 2022: BLDG-34 Rough Electrical Checklist Item 1. Rough electrical, scope of work - (partial pass)-OK (a) pending: fire department approval. 2. Missing emergency iltuminated exit sign rough electrical conduit and junction boxes. 197851-2022 Partial Pass Tony Alvarado COMMENTS BLDG-Building Deficiency December 2, 2022: BLDG-84 Rough Combo(14,24,34,44) 1. Rough electrical, scope of work - (partial pass)-OK (a) pending: fire department approval. 2. Missing emergency illuminated exit sign rough electrical conduit and junction boxes. 197927-2022 Partial Pass Tony Alvarado Reinspection Incomplete Passed Yes Reinspection Incomplete Passed Yes Reinspection Incomplete Tuesday, May 2, 2023 Page 1 of6 AIR-SOUND-HYDRONIC PROFESSIONALS HVAC Test and Balance Report PROJECT: CONTRACTOR: ARCHITECT: ENGINEER: Sully-T.I. 2510 Gateway Rd Carlsbad, CA National L 7 Studio Architects Plum Engineering REPORT CERTIFICATION NO: 42033 REPORT CERTIFICATION DATE: April 3, 2023 REVIEWED AND APPROVED BY: Michael Conboy ICB /TABB Certified Contractor 457 E. Arrow Hwy, Ste. D, Azusa, CA 91702 TEL: 62(,-915-8117 FAX: 626 915-8112 l •> 1\:IA 11 ,: •J~.;-,_~l(tat~·~l_,_1_U_:b.~•h!!-1_r~:GW!!tH.tiLr.~1-tu ...----•~.-,._-~'" ~----..------.•~=--•-~~; -~,-.~-~,-,,~ ,..--.,,~.~•"""'-"" __ .,.._."._ "" --, •-.. -<,_...,--_ ---•-~----~·-··-----·"' -~---··.<. ---0=·-=·-----o¾•····~--~,-=--..,-'"------""'-""-- STATE OF CALIFORNIA Ql:ontractorg ~rate ·JLtrense iioarb Pursuant to Chapter 9 of Division 3 of the Business and Professions Code and the Rules and Regulations of the Contractors State License Board, the Registrar of Contractors does hereby issue this license to: ' MICHAEL CONBOY INC cl6a ASSOCIATED AIR BALANCE to engage in the business or act in the capacity of a contractor in the following classification(sl: D62 -AIR AND WATER BALANCING B -GENERAL BUILDING CONTRACTOR Witness my hand and seal this day, May 9, 2008 Issued December 21, 2004 REPLACEMENT ~!:fL Registrar of Contractors This i icensc is the property of the Registrar of Contractors, is not transferrable, and shall be returned to the Registrar upon demand when suspended, revoked, or invalidated for an~· re:ison. It bt'comes void if not renewed. 851730 License Number --.~-----··-"·--=--·--· ~-,,,.,,._-----~·-----~~--..,._,__ . ...,_,..,,._,, . .,.,_....,,. --=· ·-· -·-~».·· ...... ,...,_,.-.,._'"-"""T-~•--,,,.,._ -·-"•-···--~ -~----- 1 :!L ~-l REV l :i-r.·-~ OSF Ll/ :::04W AU[llT "'0 441)746 i _l ., TB0945108C Certification# 12/8/2022 Certification Date 12/31/2024 Valid Through . I : INTER-CERTlFICATION BOARD The Sheet Metal Industry International Certification &Jard Certifies that assodated air balance Has successfully completed the requirements for TABB Contractor i• --,, ....... --="4./~.~ Labor Co-Chairperson • • ~ ·~ "S:---Managernent Co.Chairperson L,.JL~ ICBffABB Administrator l Pi -~--_:, ____ ::::.._ (& ,_I, .;:··~ f7,r&··.,,. C ' . ' ...., L~, ,. 1/.b,,,'f • , I • ' \ ,._ 4 h c ,?J .... '!.i~;,_1,:::1 INTERNATIONAL TESTING,, AOJUSTING AND 8Al.ANCING BUREAU CERTIACATION BOARD' .t THE -PROFESSIONAL'S CHOICE- TB6101708S Certification# 1/20/2023 The Sheet Metal Industry International Certification Board Certifies that Michael A Conboy Has successfully completed the requirements for TABB Supervisor r :. (,- ~ , • J./ -/ ,"\/\ __ ',~ --- \",..;._r. ,~~=:l . .... . , ' '~ _, Labor Co-Chairperson ' Certification Date ---->,;: "''" .. ,,_ , ... ~, .... ,_ \{ttq4 f ~ -------Management Co-Chairperson 12/31/2024 __ _______ii.__.___:, L-~...:..._ .... _ ..__ ·-·· - Valid Through ICB!T ABB Admmistrator ' I : -CERTIFICATION BOARD TB1044482S Ci:nification # 5/13/2022 Certification Date 12/31/2024 Valid Through TESTING. ADJUS11NG AND BAl.ANCING BURE TNE PROfESSIONAL'S CHOICE- #0728 150/IEC 17024 Personnel Certification Program The Sheet Metal Industry International Certification Board Certifies that William James Scrimmager Jr Has successfully completed the requirements for TABB Supervisor '• ,,,· ---,4~ Labor Co-Chairman . . kttwiJ~ ~- :Management Co-Chairman ,, ' :-:::.·: ·· . ..:::- :::r::a .. JL ~· ICBrr ABB Administrator ACT VAV AK w ATC WB BP WG CAV DP CD DT CE CFM CF CL CR DB DD DNL EMS ENT ESP 457 I<:, Arrow Hwy., Suite D., Azusa, CA 91723 Tel: (626) 915-8117 Fax: (626) 915-8112 Email: a,sociatedairhalance@gmail.com ABBREVIATl_9NS -Actual FH •Flow Hood (Measures CFM Dlrectly, FPM and AK -Variable Air Volume Box Factors Not Required) -Free Area Factor FPM -Feet Per Minute -Watts FPVAV -Fan Powered Variable Air Volume Box -Automatic Temperature Control GPM -Gallons per Minute -Wet Bulb HP -Horsepower -Bypass (Damper, Value, ETC) KW -Kilowatts -Water Gauge L/S -Liters Per Second -Constant Air Volume Box MB -Mixing Box -Differential Pressure NA -Not Applicable/ Access -Ceiling Diffuser NM -Not Measured -Differential Temperature NVL -No Valid location -Celling Exhaust Diffuser OSA -Outside Air -Cubic Feet Per Minute PD -Pressure Drop -Coefficient Factor RA -Return Air -Center Line REQ -Required -Ceiling Return Inlet RPM -Revolutions per Minute -Dry Bulb SA -Supply Air ~Direct Drive SFD -Smoke Fire Damper -Data Not Listed SP -Static Pressure -Emergency Management System SWR -Sidewall Return -Entering sws -Side Wall supply -External Static Pressure TDH -Total Dead Head TP -Thermal protected SULLY -2510 GATEWAY RD. CARLSBAD Table of Contents System HP-1, HP-2 Fan Test HP-1 Diffuser_Sheet HP-2 Diffuser _Sheet HP-3, HP-4 Fan Test HP-3 Diffuser _Sheet HP-4 Diffuser _Sheet HP-5 Fan Test HP-5 Diffuser _Sheet EF-1,EF-2,EF-5 Diffuser_Sheet Page Number 1 2 3 4 5 6 7 8 9 U.:l+U:lL Fan Test Data Job Name: SULLY 2510 GATEWAY RD. CARLSBAD System: (E) HP-1, HP-2 UNIT INFORMATION Unil Number (E) HP-1 Location ROOF Area Served STUDIO 111 Manufacturer PAYNE Model Number PH3GPAA36000AA-- Serial Number 3111C06556 AIR MEASUREMENTS Total Fan CFM 2,000 2,023 Total Outlet CFM 2,000 2,023 Total Return CFM 1,855 1,871 Total OSA CFM 145 152 External Fan Static Pressure 0.50" 048" Suction Static Pressure -0.28" Discharge Static Pressure 0.20'' Fan RPM HIGH/MED/LOW HIGH SPEED MOTOR MEASUREMENTS Design Actual Motor Manufacturer GENTEQ Motor HP 0.75 Motor Frame N/S 48Y Motor Voltage -Leg1/Leg2/Leg3 208 208 Motor Phase 1 1 Motor Amperage -Leg1/Leg2/Leg3 6.0 4.4 Motor Service Factor N/S TP Motor RPM N/S N/S VFD Hz. Setting N/A N/A PULLEY & BELT DATA Motor Pulley DIRECT DRIVE Fan Pulley DIRECT DRIVE Belt -Quantity/Size DIRECT DRIVE Center Distance DIRECT DRIVE % Sheave Adjusted Closed DIRECT DRIVE Motor Travel In/Out DIRECT DRIVE Remarks: Page 1 Date: 4/3/2023 Technician: M.C (E) HP-2 ROOF LOUNGE 100, CONTROL 101 PAYNE PH3GPAA36000AA-- 3111C06558 1,200 1,170 1,195 1,170 985 950 210 220 0.50" 047" -0.28" -0.19" HIGH/MED/LOW HIGH SPEED Design Actual GENTEQ 0.75 N/S 48Y 208 208 1 1 6.0 4.1 N/S TP N/S N/S NIA N/A DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Diffuser And Grille Test Data Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA System: (E) HP-1 Room Number Size Type Ak Ht-'-1 S/A 111 1 S300FS sws 1.00 111 2 S300FS sws 1.00 111 3 S300FS sws 1.00 111 4 S300FS sws 1.00 111 5 S300FS sws 1.00 111 6 S300FS sws 1.00 TOTAL HP-1 R/A 107 R-1 18" DUCT 1.76 HP-1 OSA UNIT 1 1 O"X10" HOOD 0.69 Remarks: Date: 4/3/2023 Technician: M.C. Design Actual FPM CFM FPM CFM -400 -412 -400 -415 -300 -289 -300 -285 -300 -312 -300 -310 2,000 2,023 1054 1,855 1063 1,871 210 145 220 152 U::>-,..U.JL Diffuser And Grille Test Data Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA System: (E) HP-2 Room Number Size Type Ak nr--L SIA 102 1 S300FS SWS 1.00 102 2 S300FS sws 1.00 100 3 S300FS sws 1.00 100 4 S300FS sws 1.00 100 5 S300FS sws 1.00 101 6 12" RD 1.00 TOTAL HP-2 R/A WALKWAY R-1 14" DUCT 1.00 OFFICW 102 R-2 12"X6" SWR 1.00 TOTAL HP-2 OSA UNIT 1 1 O"x1 O" HOOD 0.69 Remarks: Date: 4/3/2023 Technician: M.C. Design Actual FPM CFM FPM CFM -50 -55 -50 -50 -115 -120 -115 -118 -115 -115 -750 -712 1,195 -1,170 -915 -875 -70 -75 985 950 304 210 319 220 U.:HU.:SL Fan Test Data Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA System: (E) HP-3, HP-4 UNIT INFORMATION Unit Number (E) HP-3 Location ROOF Area Served 105, STUDIO B 107 Manufacturer PAYNE Model Number PH3GPAA36000AA-- Serial Number 3211C32312 AIR MEASUREMENTS Total Fan CFM 1,050 1,058 Total Outlet CFM 1,050 1,058 Total Return CFM 960 963 Total OSA CFM 90 95 External Fan Static Pressure 0.50" 0.53" Suction Static Pressure 0.33" Discharge Static Pressure -0.20'' Fan RPM HIGH/MED/LOW HIGH SPEED MOTOR MEASUREMENTS Design Actual Motor Manufacturer GENTEQ Motor HP 0.75 Motor Frame NIS 48Y Motor Voltage -Leg 1 /Leg2/Leg3 208 208 Motor Phase 1 1 Motor Amperage -Leg 1 /Leg2/Leg3 6.0 4.8 Motor Service Factor N/S T.P Motor RPM NIS N/S VFD Hz. Setting NIA N/A PULLEY & BELT DATA Motor Pulley DIRECT DRIVE Fan Pulley DIRECT DRIVE Belt -Quantity/Size DIRECT DRIVE Center Distance DIRECT DRIVE % Sheave Adjusted Closed DIRECT DRIVE Motor Travel In/Out DIRECT DRIVE Remarks: Page 4 Date: 4/3/2023 Technician: M.C. (E) HP-4 ROOF STUDIO B, 107 PAYNE PH3GPAA36000AA-- 3211C32343 1,980 1,989 1,980 1,989 1,830 1,832 150 157 0.50" 0.50" -0.31" 0.19" HIGH/MEO/LOW HIGH SPEED Design Actual GENTEQ 1 NIS 48Y 208 208 1 1 7.6 5.5 N/S TP N/S N/S N/A N/A DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE Ucl+U::SL Diffuser And Grille Test Data Job Name: SULLY 2510 GATEWAY RD CARLSBAD, CA System: (E) HP-3 Room Number Size Type Ak HP-3 SIA 105 1 S300FS sws 1.00 105 2 S300FS sws 1.00 107 3 S300FS sws 1.00 107 4 S300FS sws 1.00 TOTAL HP-3 R/A WALKWAY R-1 24"X12" SWR 1.00 HP-3 OSA UNIT 1 1 O"x1 O" HOOD 0.69 Remarks: Date: 4/3/2023 Technician: M.C. Design Actual FPM CFM FPM CFM -320 -305 -320 -336 -205 -216 -205 -200 1,050 1,058 -960 -963 130 90 138 95 Diffuser And Grille Test Data Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA System: (E) HP-4 Room Number Size Type Ak HP-4 SIA 109 1 S300FS sws 1.00 109 2 S300FS SWS 1.00 107 3 S300FS SWS 1.00 107 4 S300FS SWS 1.00 107 5 S300FS SWS 1.00 107 6 S300FS SWS 1.00 107 7 S300FS SWS 1.00 107 8 S300FS SWS 1.00 TOTAL HP-4 RIA WALKWAY R-1 36"X12" $WR 1.00 HP-4 OSA UNIT 1 1 0"x1 0" HOOD 0.69 Remarks: Date: 4/3/2023 Technician: M.C. Desian Actual FPM CFM FPM CFM -150 -155 -150 -150 -280 -290 -280 -294 -280 -266 -280 -276 -280 -278 -280 -280 1,980 1,989 -1,830 -1,832 217 150 227 157 Page b 03+032 Fan Test Data Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA System: (E) HP-5 UNIT INFORMATION Unit Number (E) HP-5 Location ROOF Area Served STUDIO A, 111 Manufacturer PAYNE Model Number PH3GPAA36000AA-- Serial Number 2911C05886 AIR MEASUREMENTS Total Fan CFM 1,200 1,190 Total Outlet CFM 1,200 1,190 Total Return CFM 1,090 1,080 Total OSA CFM 110 110 External Fan Static Pressure 0.50" 0.54" Suction Static Pressure 0.35" Discharge Static Pressure 0.19" Fan RPM HIGH/MED/LOW HIGH SPEED MOTOR MEASUREMENTS Design I Actual Motor Manufacturer GENTEQ Motor HP NIS 0.75 Motor Frame N/S 48Y Motor Voltage -Leg1/Leg2/Leg3 208 208 Motor Phase 1 1 Motor Amperage -Leg1/Leg2/Leg3 6.0 5 1 Motor Service Factor NIS T.P. Motor RPM NIS N/S VFD Hz. Setting NIA NIA PULLEY & BELT DATA Motor Pulley DIRECT DRIVE Fan Pulley DIRECT DRIVE Belt -Quantity/Size DIRECT DRIVE Center Distance DIRECT DRIVE % Sheave Adjusted Closed DIRECT DRIVE Motor Travel In/Out DIRECT DRIVE Remarks: Page 7 Date: 4/312023 Technician: M.C. Design Actual U3+U:lZ Diffuser And Grille Test Data Job Name: SULLY 2510 GATEWAY RD. CARLSBAD, CA System: (E) HP-5 Room Number Size Type Ak Ht'-4 SIA 111 1 S300FS SWS 1.00 111 2 S300FS SWS 1.00 111 3 S300FS SWS 100 111 4 S300FS SWS 100 111 5 S300FS SWS 100 111 6 S300FS SWS 1.00 TOTAL HP-5 RIA 111 R-1 1611 DUCT 1.40 HP-5 OSA UNIT 1 1 O"x1 O" HOOD 0.69 Remarks: Date: 41312023 Technician: M.C. Design Actual FPM CFM FPM CFM -200 -210 -200 -190 -200 -190 -200 -195 -200 -205 -200 -200 1,200 1,190 779 1,090 771 1,080 159 110 159 110 Page 8 U:S+U:SL Diffuser And Grille Test Data Job Name: SULLY 2510 GATEWAY RD CARLSBAD, CA System: (E) EF-1, EF-2, EF-5 Room Number Size Type Ak tcr--1 E/A RR 103 1 12"X10" EG 1.00 EF-2 E/A RR 104 1 12"X10" EG 1.00 EF-5 E/A RR 1 12"X10" EG 1.00 Date: 4/3/2023 Technician: M.C. Design Actual FPM CFM FPM CFM -150 -150 -150 -155 . N/S . 150 Remarks: CEILING MOUNTED EXHAUST FANS NO FAN TEST SHEET REQUIRED Page~ SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY RECORD ID # ___________________ 1 PLAN CHECK # __________________ 1 BP DATE Business Name SULLY ASSET GROUP, LLC Project Address 2510 GATEWAY ROAD Mailing Address 2510 GATEWAY ROAD Project Contact JOHN LETTER usiness Contact OBERT SULLIVAN State CA Telephone# 858,353-0945 Ztp Code 92009 APN# 213-261-15-00 City State Zip Code Plan File# <:;f \JBAD CA 92009 A 'li\'\<'11 E-mail Telephone # , :vClhlNLETTER@L7STUDIOARCHITECTS.COM 858.952.8166 Tho foflo · tjuest{9fi,S,r8present the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMEN -H~ 'M .TERIALS DIVISION: OCCUPANC CLA SIFICATION: not re uired for ro·ects within th Cit I San Ole o : Indicate by circling the item, & er your business will use, process, or store any o the folfowIng hazardous materials If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittaL Occupancy Rating: Facility's Square Footage {including proposed project): 1. Explosive or Blasting Agents 5. Organic Peroxides g_ Water Reacflves 13. Corrosives 2. Compressed Gases 6, Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11 Highly Toxic or Toxic Materfals 15. None of These. 4. Flammable Solids 8 Unstable Reactives 12. Radloactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION /HMO!: If lhe answer to any of lhe questions is yes, applicant must contact !he County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123. Call (858) 505~6700 prior to the issuance of a building pem,it FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 0 CaJARP Exempt I 1. 2. 3. 4 5. 6. 7. 8. YES NO (for new construction or remodeling projects) Is your business listed on the reverse side of this form? (check all that apply). D ll9 D 119 Will your business dispose of Hazardous Substances or Medical Waste in any amount? D [lg Will your business store or handle Hazardous Substances In quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? D D D D D ~ Will your business store or handle carcinogens/reproductive toxins in any quantity? @ Will your business use an existing or install an underground storage tank? ~ Will your business store or handle Regulated Substances (CalARP)? IZI Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? ~ WIii your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or reater than 1,320 allons? California's Above round Petroleum Stora e Act . Date Initials 0 CalARP Required I Dale Initials 0 CalARP Complete I Date lnltials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT APCD : Any YES~ answer requires a stamp from APCD 10124 Old Grove Road, San Dlego, C 92131 apcdcomp@sdcounty.ca.gov (858 586~2650 . {"No stamp required if Q1 Yes mill Q3 Yes~ 04-06 No]. The following questions are intended to Identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except -those with more than one building• on the property; single buildings with more than four dwelling units; townhomes; condos; mixed~commercial use; deliberate burns; residences forming part of a larger project. rExcludes garages & small outbuildings.] 1. 2. 3. 4. 5. 6. YES NO 00 D D IX! D Qil D D [lg ~ Will the project disturb 160 square feet or more of existing building materials? Will any load supporting structural members be removed? Notification may be required 1 O working days prior to commencing demolition. (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior to commencing asbestos removal- Will the project or associated construction equipment emit afr contaminants? See the reverse side of this fom, or APCD factsheel (www.sdapgd.org/info/facls/pennits.pdf) for typical equipment requiring an APCD permit. D ~ (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school bounda activities: Briefly describe proposed project: TENANT IMPROVEMENT FITNE NTER I declare under penalty of perjury that to the best of my knowledge and bpli';'f t ,,,_ responses made herein are true and correct. JOHN J LETTER ' 01 J 21 / 2022 Name of Owner or Authorized Agent SiQnature of Owner or Authorized Agent Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _______________________________ _ BY· DATE· I I EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO~ APCD COUNTY-HMO APCD COUNTY-HMO APCD ';)\,\on if-" C Reviewed 0 ii 10/24/2022 TW :1: 0Me/1nitiafs ..r ~// ,f co" *A stamp In this box .Q!!h! exempts busrnesses from completing or updating a Hazardous Matenals Business Plan. Other perm1ttmg requirements may still apply. HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division Building Permit Finaled Revision Permit Print Date: 05/02/2023 Job Address: Permit No: Status: ( City of Carlsbad PREV2023-0011 Closed -Finaled Permit Type: 2510 GATEWAY RD, # 101, BLDG-Permit Revision CARLSBAD, CA 92009-1727 Work Class: Commercial Permit Revision Parcel#: 2132611513 Valuation: $0.00 Occupancy Group: B #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: 2019 Sprinkled: Yes Project Title: Track#: Lot#: Project#: Plan#: Construction Type:V-B Orig. Plan Check#: CBC2022-0261 Plan Check#: Description: SULLY OFFICE COM-Tl: REVISIONS TO MECH,ELEC,PLUM/PARTITIONS Applicant: L7 STUDIO ARCHITECTS JOHN LETTER 5190 GOVERNOR DR, # 204 SAN DIEGO, CA 92122-2847 (858) 952-8166 FEE BUILDING PLAN CHECK FEE (manual) Total Fees: $300.00 Building Division Total Payments To Date: $300.00 Applied: 02/02/2023 Issued: 04/18/2023 Finaled Close Out: 05/02/2023 Final Inspection: INSPECTOR: Contractor: VILLAGE PROPERTY SYSTEMS INC 4920 CARROLL CANYON RD, # STE 200 SAN DIEGO, CA 92121-3735 (858) 755-1800 Balance Due: AMOUNT $300.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov {'city of Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION 8-15 Development Services Building Division 1635 Faraday Avenue 442-339-2719 www.carlsbadca.gov No: CBC2022-026 I ,{1/J .c"\ , ., ""3 ,-,,,, I I Original Plan Check Number ________ Plan Revision Number'fl'<,,ev u-,,~ -CJ./ Project Address 25 IO GATEWAY ROAD, CARLSBAD, CA 92009 General Scope of Revision/Deferred Submittal: REVISIONS TO NON-BEARING PARTITIONS ASSOCIATED REVISIONS TO MECHANICAL, ELECTRICAL, AND PLUMBING CONTACT INFORMATION: Name JOHN LETTER Phone 858.952.8 I 66 ________ Fa"----------~ Ad-ttzo~ GOVERNOR DRIVE, SUITE 204 City SAN DIEGO 92122 Zip ____ _ E .1 Add JOHNLETTER@L7STUDIOARCHITECTS.COM ma, ress ------------------------------- Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: Ii] Plans O Calculations O Soils O Energy O Other 2. 3. Describe revisions in detail List page(s) where each revision is shown SEE ATTACHED DOCUMENT 4. Does this revision, in any way, alter the exterior of the project? 0 Yes Ii] No 5. Does this revision add ANY new floor area(s)? 0 Yes O No 6. Does this revision affect any fire related issues? 0 Yes Ii] No 7. Is this a completeFse? Ii] Yes O No 02.02.2023 ~Signature __ +---+----------------Date 1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 442-339-2719 f;!/1: 760-602-8558 Email: building@carlsbadca.govwww.carlsbadca.gov