HomeMy WebLinkAboutDWG 538-7A; CT 2021-0005; CHINQUAPIN COASTAL HOMES; 01-13G
A
R
F
I
E
L
D
S
T
CHIN
Q
U
A
P
I
N
A
V
E
H
I
G
H
W
A
Y
1
0
1
SITETAM
A
R
A
C
K
A
V
E
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
BAK
PUD 2021-0010
PA
S
C
O
,
L
A
R
E
T
,
S
U
I
T
E
R
&
A
S
S
O
C
I
A
T
E
S
53
5
N
.
H
W
Y
1
0
1
,
S
U
I
T
E
A
,
S
O
L
A
N
A
B
E
A
C
H
,
C
A
9
2
0
7
5
PH
:
(
8
5
8
)
2
5
9
-
8
2
1
2
F
A
X
:
(
8
5
8
)
2
5
9
-
4
8
1
2
CT 2021-0005 538-7A
GR 2022-0029
PLSA 3729
1
J:\ACTIVE JOBS\3729 RINCON 330 CHINQUAPIN\CIVIL\DRAWING\GRADING PLANS\3729-CV-GP-01-TITLE.DWG
13
N.T.S.
FIRM: PASCO, LARET, SUITER, AND ASSOCIATES, INC.
ADDRESS: 1911 SAN DIEGO AVE, SUITE 100
CITY, STATE: SAN DIEGO, CA 92110
TELEPHONE: (858) 259-8212
BY:
R.C.E. NO.:
REGISTRATION EXPIRATION DATE:
I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED
RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS
AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS.
I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD
DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN.
DATE:
CUT:
FILL:
IMPORT:
EXPORT:
REMEDIAL:
CY
CY
CY
CY
CY
TOTAL LOT AREA =
TOTAL DISTURBED AREA =
*TOTAL NEW / REPLACED IMPERVIOUS AREA =
THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA STATE PLANE COORDINATE SYSTEM NAD
83, ZONE 6, 1991.35 EPOCH BASED ON THE GRID BETWEEN STATION "CLSB 141" AND STATION "CLSB 119"
AS SHOWN ON RECORD OF SURVEY NUMBER 17271, BOTH HAVING COORDINATE VALUES OF 1ST ORDER
OR BETTER I.E; N 66°04'32" E.
SIGNED:
G.E./P.E. NO.:
DATE:
LICENSE EXPIRATION DATE:
(THIS AREA INCLUDES BUT IS NOT LIMITED TO OFF-SITE WORK INCLUDING PUBLIC
IMPROVEMENTS AND TEMPORARY DISTURBANCE SUCH AS VEHICLE AND EQUIPMENT
STAGING AREAS, CONSTRUCTION TRENCHES, BACKFILL CUTS AND SLOPE KEYWAYS)
TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERATED BY FIELD SURVEY METHODS FROM
INFORMATION GATHERED ON: NOVEMBER 10, 2021
BY: PASCO, LARET, SUITER & ASSOCIATES
TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS.
1. ACTUAL STRUCTURAL SECTIONS WILL BE DETERMINED AFTER "R" VALUE TESTS HAVE BEEN CONDUCTED
BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE
FIELD OF APPLIED SOIL MECHANICS, ON THE PREPARED BASEMENT SOIL. THE "R" VALUE TESTS AND
THE ENGINEERED STRUCTURAL SECTION MUST BE SUBMITTED TO THE ENGINEERING INSPECTOR FOR
REVIEW AND APPROVAL A MINIMUM OF TWO (2) CITY WORKING DAYS BEFORE THE WORK BEGINS.
2. STREET LIGHTS SHALL BE INSTALLED AS SHOWN ON THESE PLANS, UNDERGROUND CONDUIT RUNS,
SERVICE POINTS AND HAND-HOLES SHALL BE SHOWN ON THE "AS-BUILT" PLANS. NO DIRECT BURIAL
STREET LIGHT FOUNDATIONS WILL BE ALL LUMINAIRES SHALL BE "CUT OFF" TYPE ALLOWED.
3. ALL UNDERGROUND UTILITIES AND LATERALS SHALL BE INSTALLED PRIOR TO CONSTRUCTION OF CURBS,
CROSS GUTTERS OR SURFACING OF STREETS.
4. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED IT SHALL BE REMOVED WITHIN TWENTY FEET OF
BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE
PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER.
5. WHEELCHAIR RAMPS SHALL BE INSTALLED PER REQUIREMENTS OF TITLE 24, CALIFORNIA ADMINISTRATIVE
CODE.
6. STREET TREES SHALL BE INSTALLED PER SECTION VI OF THE CITY OF CARLSBAD LANDSCAPE MANUAL.
7. FIRE HYDRANT MARKERS SHALL BE PLACED IN THE STREET WITHIN THE LIMITS OF WORK OF THIS PLAN
PER SDRSD DWG M19.
8. ALL SURVEY MONUMENTS AND POINTS THAT ARE DISTURBED BY THIS WORK SHALL BE
REESTABLISHED, PERPETUATED, AND DOCUMENTED PER THE PROFESSIONAL LAND SURVEYORS
ACT.
9. TWO (2) SETS OF SURVEY (CUT) SHEETS SHALL BE PROVIDED TO THE CITY ENGINEERING INSPECTOR.
10. STREET LIGHTS SHALL BE 5,500 LUMEN (40 WATT) OR 13,700 PUPIL LUMEN (100 WATT) HIGH EFFICIENCY
INDUCTION LIGHTS.
THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S): 206-020-11-00
THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: N_____________ E________________
(CCS 83)
ADDRESS: 245 ACACIA AVENUE, CARLSBAD, CA 92008
SIGNED:
9,776 SF *NOTE: QUANTITIES WITHIN / SUBSET
OF DISTURBED AREA
DISTURBED ROW AREA =
I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR
WILL BE RETAINED TO SUPERVISE OVER-ALL GRADING ACTIVITY AND ADVISE ON THE
COMPACTION AND STABILITY OF THIS SITE. IF THIS PROJECT/DEVELOPMENT IS SUBJECT TO A
STATE-REGULATED SWPPP, I (WE) ALSO AGREE A QUALIFIED SWPPP PRACTITIONER QSP HAS
BEEN OR WILL BE RETAINED TO SUPERVISE IMPLANTATION OF THE SWPPP IN ACCORDANCE
WITH THE CALIFORNIA CONSTRUCTION ORDER AND MUNICIPAL PERMIT, LATEST VERSION.
KEVIN DUNN FOR: 330 CHINQUAPIN LLC
DESCRIPTION:
LOCATION:
RECORDED:
ELEVATION:DATUM:
NAME:
ADDRESS:
PHONE NO.:
NGVD 29
1 TITLE SHEET / NOTES
2 DEMO PLAN
3 GRADING PLAN
4 SECTIONS AND DETAILS
5 TIER 2 SWPPP COVER SHEET
6 TIER 2 SWPPP
7 SINGLE SHEET BMP
8 SHORING PLAN
9-10 SHORING PROFILES
10-11 SHORING DETAILS
12 SHORING NOTES
123.77'
NAME:
BW = BOTTOM OF WALL
ELEVATION
EG = EXISTING GRADE
FS = FINISHED SURFACE
FG = FINISHED GRADE
FL = FLOWLINE
FF = FINISHED FLOOR
GF = GARAGE FACE
IE = INVERT ELEVATION
LA = LANDSCAPE AREA
TG = TOP OF GRATE ELEVATION
RIM = TOP OF RIM ELEVATION
TW = TOP OF WALL ELEVATION
TW@EG = TOP OF WALL AT
EXISTING GRADE
FYSB = FRONT YARD SETBACK
RYSB = REAR YARD SETBACK
SYSB = SIDE YARD SETBACK
ADDRESS:
PHONE NO.:
KEVIN DUNN FOR:
RINCON REAL ESTATE GROUP
5315 AVENIDA ENCINAS, SUITE 200
CARLSBAD, CA 92008
THE GRADING WORK SHALL CONSIST OF THE CONSTRUCTION OF ALL CUTS AND FILLS, REMEDIAL
GRADING, DRAINAGE FACILITIES, EROSION CONTROL FACILITIES, AND PLANTING OF PERMANENT
LANDSCAPING AND PREPARATION OF AS-BUILT GRADING PLANS, AS-BUILT GEOLOGIC MAPS AND
REPORTS, ALL AS SHOWN OR REQUIRED ON THIS SET OF PLANS AND THE CITY STANDARDS,
SPECIFICATIONS, REQUIREMENTS, RESOLUTIONS AND ORDINANCES CITED ON THESE PLANS.
THE GRADING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS,
CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER.
330 ACACIA AVENUE
CARLSBAD, CA 92008
APN: 206-020-11-00
330 CHINQUAPIN LLC
5315 AVENIDA ENCINAS, SUITE 200
CARLSBAD, CA 92008
19,247 SF
800
50
2,140
0
750
(949) 637-3254
(949) 637-3254
1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT KEVIN DUNN AT (949)637-3254, 24 HOURS A DAY.
2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING
THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCATIONS TO
FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS EMINENT.
3. FOR PROJECTS COVERED BY STATE SWPPP/WDID, IN ACCORDANCE WITH THE CONSTRUCTION ORDER
ISSUED BY THE CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD, THE QUALIFIED SWPPP PRACTITIONER
(QSP) SHALL UPDATE AND MAINTAIN THE WATER POLLUTION CONTROL PLAN (WPCP) TO ADDRESS UPDATED SITE
CONDITIONS OF THE PROJECT. THE UPDATED WPC PLAN AND UPDATED SWPPP SHALL BE KEPT AT THE PROJECT
SITE AND MADE AVAILABLE TO THE CITY INSPECTOR. ADDITIONAL CONSTRUCTION BMP'S BEYOND THE ORIGINAL
APPROVED SWPPP SHALL BE PROVIDED TO ADDRESS SITE CONDITIONS NOT ANTICIPATED. THE QSP SHALL
REPORT BMP DEFICIENCIES TO THE CITY INSPECTOR. THE QSP SHALL OBTAIN APPROVAL FROM THE QUALIFIED
SWPPP DEVELOPER AND THE CITY INSPECTOR REGARDING ANY SIGNIFICANT CHANGES TO BMP DEPLOYMENT.
4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE
SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL.
5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE
CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY
ARISE.
6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT
PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION.
7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED SWPPP AND/OR EROSION CONTROL
PLAN SHALL BE INCORPORATED HEREON.
8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE
CONCLUSION OF EACH WORKING DAY.
9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY
WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER
DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL.
10. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGRATE.
11. SHOULD GERMINATION OF HYDROSEEDED SLOPES FAIL TO PROVIDE EFFECTIVE COVERAGE OF GRADED
SLOPES (90% COVERAGE) PRIOR TO NOVEMBER 15, THE SLOPES SHALL BE STABILIZED BY PUNCH STRAW
INSTALLED IN ACCORDANCE WITH SECTION 35.023 OF THE EROSION AND SEDIMENT CONTROL HANDBOOK OF
THE DEPARTMENT OF CONSERVATION, STATE OF CALIFORNIA.
I, JAIME CERROS, A REGISTERED GEOTECHNICAL ENGINEER OF THE STATE OF CALIFORNIA,
PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS, HEREBY CERTIFY THAT A
SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR
UNDER MY DIRECTION ON 10/5/2021. TWO COPIES OF THE SOIL REPORT COMPILED FROM THIS
STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER.
1. CARLSBAD MUNICIPAL CODE
2. CITY OF CARLSBAD ENGINEERING STANDARDS
3. THIS SET OF PLANS
4. RESOLUTION NO 7456 DATED JULY 20, 2022
5. THE STANDARD SPECIFICATIONS FOR PUBLIC
WORKS CONSTRUCTION (GREEN BOOK)
6. SOILS REPORT AND RECOMMENDATIONS BY
GEOTECHNICAL EXPLORATION, INC: JOB. NO.
21-13506 DATED 10/28/21
7. THE SAN DIEGO REGIONAL STANDARD DRAWINGS
AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD
STANDARDS
8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT
PERMIT CONDITIONS DATED _________
9. ENVIRONMENTAL APPROVAL DOCUMENTS
DATED________
10. STORM WATER POLLUTION PREVENTION PLAN (TIER 2)
11. STORM WATER QUALITY MANAGEMENT PLAN
PREPARED BY: ___________ DATED: _______________
SWMP NO._______
12. CALIFORNIA STORM WATER QUALITY ASSOCIATION
BMP CONSTRUCTION HANDBOOK AND CALTRANS
CONSTRUCTION SITE BMP MANUAL
PLSAPREPARED BY: ___________ , SEE SHEETS 5-6
PLSA
N/A
N/A
R.C.E. 34422 G.E. 2007
ABBREVIATION:
SDRSD - SAN DIEGO REGIONAL STANDARD DRAWING
CMWD - CARLSBAD MUNICIPAL WATER DISTRICT
* NOTE: MODIFIED PER CITY OF CARLSBAD STANDARD
TYPE DESCRIPTION OWNERSHIP AGREEMENT SHEET NO.FREQUENCY
MAINTENANCE MAINTENANCE
STORMWATER REQUIREMENTS THAT APPLY:
STANDARD STORMWATER REQUIREMENTS
PRIORITY PROJECT REQUIREMENTS
YES
NO
EXEMPT FROM
YES
NO
EXEMPT FROM
TRASH CAPTURE?HYDROMODIFICATION?
TRASH CAPTURE
DWG 538-7A
HOA 3 AS NEEDED
SEPTEMBER 30,2023
358 1655
MAP 1803DWG 146-6
DWG 159-9
DWG 387-8
BRYAN A. KNAPP, R.C.E.
86542
03-31-2025
2,958 SF
22,205 SF
NORTHEASTERLY HALF OF LOT 3 IN BLOCK "S" OF PALISADES NO. 2, IN THE CITY OF
CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP
THEREOF NO. 1803, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO
COUNTY AUGUST 25, 1924, THE SOUTHWESTERLY BOUNDARY LINE THEREOF BEING
PARALLEL WITH AND DISTANT 70.00 FEET SOUTHWESTERLY FROM NORTHEASTERLY
BOUNDARY LINE OF SAID LOT.
STORMTEK
PIPE CONNECTOR SCREEN
AT THE CENTER OF BULB, 190 FT. SOUTH OF INTERSECTION OF VISTA BELLA
AND BELLA LAGUNA COURT AS SHOWN ON RECORD OF SURVEY NUMBER
17271, AS POINT CLSB-119
WELL MONUMENT
2002
MAY 5, 2022
PARTIALLY COMPLETED PROJECTS SEEKING TO INDEFINITELY STOP WORK AND CLOSE THE GRADING PERMIT
MUST IMPLEMENT APPROPRIATE ACCESS RESTRICTION AND EROSION AND SEDIMENT CONTROL MEASURES TO
THE SATISFACTION OF THE CITY, INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
1) PERMANENTLY STABILIZE ALL SLOPES (>5%) - 70% COVER WITH WELL-ESTABLISHED, SUSTAINABLE,
NON-WEED VEGETATION (SEE CITY LANDSCAPE MANUAL FOR GUIDELINES) IS CONSIDERED
ADEQUATE.
2) PERMANENTLY STABILIZE FLAT AREAS (≤5%) - 70% COVER WITH WELL-ESTABLISHED, SUSTAINABLE,
NON-WEED VEGETATION (SEE CITY LANDSCAPE MANUAL FOR GUIDELINES) OR 2 INCHES (MINIMUM) OF
PERMEABLE COVER (E.G., GRAVEL) IS CONSIDERED ADEQUATE.
3) RESTRICT ACCESS TO SITE - COORDINATE WITH CITY STAFF TO DETERMINE APPROPRIATE FENCING TYPE.
4) SIGNAGE ALONG FRONTAGE ROAD(S) POSTING THAT DUMPING, LITTERING, AND TRESPASSING ARE
PROHIBITED.
5) TRESPASS ENFORCEMENT AUTHORIZATION LETTER MUST BE SENT FROM THE OWNER TO THE CITY OF
CARLSBAD POLICE DEPARTMENT.
6) NOTARIZE AND RECORD AGAINST THE PROPERTY AN AGREEMENT STATING THAT OWNER IS RESPONSIBLE
FOR MAINTAINING FENCING AND SIGNAGE, ADHERING TO THE FIRE PREVENTION ORDINATION, KEEPING
THE SITE FREE FROM LITTER ACCUMULATION AND VEGETATION GROWTH, AND REMOVING ANY ILLEGALLY
DUMPED MATERIALS AT THE SITE UNTIL THE PROPERTY IS DEVELOPED IN THE FUTURE.
(IN ADDITION TO THE REQUIREMENTS OF CHAPTER 15.16 OF THE CARLSBAD MUNICIPAL CODE.)
1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD
REGARDING GRADING SHOWN ON THIS SET OF PLANS.
2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD
MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER
ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE
ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE
IS DISCOVERED.
3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER-OF- WORK FROM
RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING
CONSTRUCTION. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY
ENGINEER FOR APPROVAL.
4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE
PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A CERTIFICATE OF INSURANCE AS
WELL AS ADDITIONAL INSURED ENDORSEMENT MUST BE FILED NAMING THE CITY OF
CARLSBAD AS AN ADDITIONAL INSURED ON THE PERMITTEE'S POLICY IN THE MINIMUM
AMOUNT OF $1,000,000.00 FOR EACH OCCURRANCE OF LIABILITY. THE INSURANCE COMPANY
WRITING THE POLICY MUST HAVE A RATING OF "A-" OR BETTER AND A SIZE CATEGORY OF
CLASS VII OR BETTER AS ESTABLISHED BY "BESTS" KEY RATING GUIDE.
5. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY AND
OTHER APPROPRIATE AGENCIES.
6. REVISION OF THESE PLANS MAY BE REQUIRED IF THE PROPOSED IMPROVEMENTS ARE
NOT CONSTRUCTED PRIOR TO THE DEADLINE DATE OF THE IMPROVEMENT AGREEMENT.
7. APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY WORK OR
GRADING TO BE PERFORMED UNTIL THE PROPERTY OWNER'S PERMISSION HAS BEEN OBTAINED
AND A VALID GRADING PERMIT HAS BEEN ISSUED.
8. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY
ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS
AND THE TITLE SHEET.
9. ORIGINAL DRAWINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE
CITY ENGINEER.
10. THE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY THE
ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY.
11. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT
SITE AT ALL TIMES DURING CONSTRUCTION.
12. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: (A)
SUMMARY SHEET, (B) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE
SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY
DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL
BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF THE
COMPLETION OF FIELD TESTS.
13. A SOILS COMPACTION REPORT AND COMPLIANCE VERIFICATION REGARDING ADHERENCE TO
RECOMMENDATIONS OUTLINED IN THE SOILS REPORT IS REQUIRED PRIOR TO THE ISSUANCE
OF A BUILDING PERMIT. ALL CONTROLLED GRADING SHALL BE DONE UNDER THE DIRECTION OF
A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA PRINCIPALLY DOING BUSINESS
IN THE FIELD OF APPLIED SOILS MECHANICS. ALL FILL OR FUTURE FILL AREAS SHALL BE
CONSTRUCTED IN ACCORDANCE WITH THE CITY OF CARLSBAD STANDARD SPECIFICATIONS AND
THE " EARTHWORK SPECIFICATIONS " ATTACHED TO THE PRELIMINARY SOILS
INVESTIGATION. DAILY FIELD COMPACTION REPORTS WILL BE SUBMITTED TO THE PROJECT
INSPECTOR.
14. A PRECONSTRUCTION MEETING SHALL BE HELD PRIOR TO THE BEGINNING OF WORK AND
SHALL BE ATTENDED BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION,
INSPECTION, SUPERVISION, TESTING AND ALL OTHER ASPECTS OF THE WORK. THE
CONTRACTOR WILL BE CONTACTED BY THE PROJECT INSPECTOR TO COORDINATE A DATE
AND TIME FOR THE PRECONSTRUCTION MEETING. APPROVED DRAWINGS MUST BE AVAILABLE
PRIOR TO SCHEDULING. THE GRADING PERMIT WILL BE PROVIDED BY THE PROJECT INSPECTOR
AT THE MEETING.
15. ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCTION MEETING WILL BE MADE BY
CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT (760) 438-3891. INSPECTION
REQUEST MUST BE RECEIVED PRIOR TO 2:00 P.M. ON THE WORKING DAY BEFORE THE
INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST
OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS
LATER.
16. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL
DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND
SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY
AND HEALTH STANDARDS, LAWS AND REGULATIONS.
17. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL
PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF
SHORING, BRACING SLOPING OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION
FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR
TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED
FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER
AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE
SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS,
TITLE 8 CALIFORNIA ADMINISTRATIVE CODE, THE PLAN SHALL BE PREPARED BY A
REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA
EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION.
19. IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK AREA DURING
CONSTRUCTION, OPERATIONS WILL CEASE IMMEDIATELY, AND THE PERMITTEE WILL
NOTIFY THE CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS
RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO.
20. ALL OPERATIONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING
UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING
EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED GRADING
EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 A.M. AND 6:00 P.M. EACH
DAY, MONDAY THRU FRIDAY AND NO EARTHMOVING OR GRADING OPERATIONS SHALL BE
CONDUCTED ON WEEKENDS OR HOLIDAYS. (A LIST OF CITY HOLIDAYS IS AVAILABLE AT THE
ENGINEERING DEPARTMENT COUNTER.)
21. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY
INSPECTOR FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE
HAUL ROUTE OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION.
23. BRUSH SHALL BE REMOVED ONLY WITHIN THE AREA TO BE GRADED. NO TREES ARE TO BE
REMOVED UNLESS SPECIFICALLY NOTED ON THE PLAN.
24. ALL AREAS SHALL BE GRADED TO DRAIN. GRADING RESULTING IN THE PONDING OF WATER IS NOT
PERMITTED. ALL EARTHEN SWALES AND DITCHES SHALL HAVE A MINIMUM ONE PERCENT SLOPE.
25. THESE PLANS ARE SUBJECT TO A SIGNED AND APPROVED SWPPP AND/OR SET OF EROSION
CONTROL PLANS. EROSION CONTROL SHALL BE AS SHOWN AND AS APPROVED BY THE CITY
ENGINEER OR AS DIRECTED BY THE PROJECT INSPECTOR.
26. ALL SLOPES SHALL BE TRIMMED TO A FINISH GRADE TO PRODUCE A UNIFORM SURFACE AND
CROSS SECTION. THE SITE SHALL BE LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES,
ROOTS OR OTHER DEBRIS SHALL BE REMOVED AND DISPOSED OF AT A SITE APPROVED OF BY THE
CITY ENGINEER.
27. ALL SLOPES SHALL BE IRRIGATED, STABILIZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN (10)
DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED
GRADING PLANS.
22. IMPORT MATERIAL SHALL BE OBTAINED FROM, AND WASTE MATERIAL SHALL BE DEPOSITED AT, A
SITE APPROVED BY THE CITY ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY
DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A
RESULT OF THE GRADING OPERATION.
18. NO BLASTING SHALL BE PERFORMED UNTIL A VALID BLASTING PERMIT HAS BEEN OBTAINED FROM
THE CITY OF CARLSBAD. SUBMIT APPLICATION FOR BLASTING PERMIT WELL IN ADVANCE OF THE
SCHEDULING OF BLASTING OPERATIONS.
28. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY OF
CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT, DRAWING NO.
538-7L, AND/OR AS DIRECTED BY THE CITY ENGINEER OR PLANNING DIRECTOR.
29. THE OWNER/APPLICANT SHALL INSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK OF
THESE GRADING PLANS WITH THAT SHOWN ON BOTH THE LANDSCAPE AND IRRIGATION PLANS AND
THE IMPROVEMENT PLANS AS REQUIRED FOR THIS WORK IN ACCORDANCE WITH THE LANDSCAPE
MANUAL TIME REQUIREMENTS.
30. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED AS A RESULT OF THE GRADING
OPERATION, IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND
REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED
WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER.
31. THE EXISTENCE AND LOCATION OF UTILITY STRUCTURES AND FACILITIES SHOWN ON THE
CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ATTENTION IS
CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITY FACILITIES OR STRUCTURES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR IS
REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE
PLANS AND ANY OTHER EXISTING FACILITIES OR STRUCTURES NOT SHOWN.
32. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES ( ABOVE GROUND AND
UNDER GROUND ) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF GRADING TO PERMIT THE
REVISION OF THE GRADING PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT
WITH THE PROPOSED WORK.
33. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST 2 FULL
WORKING DAYS PRIOR TO STARTING GRADING NEAR THEIR FACILITIES AND SHALL COORDINATE
THE WORK WITH A COMPANY REPRESENTATIVE.
UNDERGROUND SERVICE ALERT (800)422-4133
SDG&E (800)411-7343
AT&T (800)892-0123
TIME WARNER CABLE (760)438-7741
COX COMMUNICATIONS (619)262-1122
CITY OF CARLSBAD(STREETS & STORM DRAIN) (760)434-2980
CITY OF CARLSBAD(SEWER,WATER & RECLAIMED WATER) (760)438-2722
SAN DIEGUITO WATER DISTRICT (760)633-2650
LEUCADIA WASTEWATER DISTRICT (760)753-0155
VALLECITOS WATER DISTRICT (760)744-0460
OLIVENHAIN WATER DISTRICT (760)753-6466
BUENA SANITATION DISTRICT (760)726-1340 x1330
AS APPROPRIATE
34. PERMIT COMPLIANCE REQUIREMENTS:
A. FOR CONTROLLED GRADING - THE APPLICANT HIRES A CIVIL ENGINEER, SOILS ENGINEER,
AND/OR GEOLOGIST TO GIVE TECHNICAL ADVICE, OBSERVE AND CONTROL THE
WORK IN PROGRESS {15.16.120 A.8} CARLSBAD MUNICIPAL CODE.
B. PRIOR TO FINAL APPROVAL OF A GRADING PERMIT - THE FOLLOWING REPORTS MUST
BE SUBMITTED TO THE CITY ENGINEER VIA THE PROJECT INSPECTOR {15.16.120 A.10}
CARLSBAD MUNICIPAL CODE:
(1) FINAL REPORT BY SUPERVISING GRADING ENGINEER STATING ALL GRADING IS
COMPLETE. ALL EROSION CONTROL, SLOPE PLANTING AND IRRIGATION ARE
INSTALLED IN CONFORMANCE WITH CITY CODE AND THE APPROVED PLANS (
OBTAIN SAMPLE OF COMPLIANCE LETTER FROM CITY ENGINEERING
DEPARTMENT).
(2) AS-BUILT GRADING PLAN.
(3) REPORT FROM THE SOILS ENGINEER, WHICH INCLUDES RECOMMENDED SOIL
BEARING CAPACITIES, A STATEMENT AS TO THE EXPANSIVE QUALITY OF
THE SOIL, AND SUMMARIES OF FIELD AND LABORATORY TESTS AND
PLOTTED TEST POINTS THE REPORT SHALL ALSO INCLUDE A STATEMENT
BY THE SOILS ENGINEER THAT THE GRADING WAS DONE IN ACCORDANCE
WITH THE REQUIREMENTS AND RECOMMENDATIONS OUTLINED IN THE
PRELIMINARY SOILS REPORT AND ANY SUPPLEMENTS THERETO.
(4) REPORT WITH AS-BUILT GEOLOGIC PLAN, IF REQUIRED BY THE CITY.
35. UNLESS A GRADING PERMIT FOR THIS PROJECT IS ISSUED WITHIN ONE (1) YEAR AFTER THE CITY
ENGINEER'S APPROVAL, THESE PLANS MAY BE REQUIRED TO BE RESUBMITTED FOR PLANCHECK.
PLANCHECK FEES WILL BE REQUIRED FOR ANY SUCH RECHECK.
35.IN ACCORDANCE WITH THE CITY STORM WATER STANDARDS, ALL STORM DRAIN INLETS CONSTRUCTED
BY THIS PLAN SHALL INCLUDE "STENCILS" BE ADDED TO PROHIBIT WASTEWATER DISCHARGE
DOWNSTREAM. STENCILS SHALL BE ADDED TO THE SATISFACTION OF THE CITY ENGINEER.
GEOTECHNICAL EXPLORATION INC. PHONE NUMBER: (858) 549-7222
SIGNATURE DATE
WITH THE CALIFORNIA CONSTRUCTION ORDER AND MUNICIPAL PERMIT, LATEST VERSION.
3/22/2023
03-31-2023
*AS MODIFIED BY CITY OF
CARLSBAD STANDARDS
PROPERTY BOUNDARY
CENTERLINE OF ROAD
ADJACENT PROPERTY LINE
PUBLIC RIGHT-OF-WAY
SETBACK LINE
EXISTING CONTOUR LINE
PROPOSED CONTOUR LINE
PROPOSED FLOWLINE
PROPOSED DIRECTION OF FLOW
PROPOSED 6" PCC CURB AND GUTTER
PROPOSED 6" PCC CURB
PROPOSED PCC FLUSH CURB (SIZE PER PLAN)
PROPOSED MASONRY RETAINING WALL
PROPOSED SHORING WALL (DESIGN BY
OTHERS)
PROPOSED DEEPENED FOOTING PER
SEPARATE ARCHITECTURAL PLAN
PROPOSED PCC PAVEMENT*
PROPOSED PERVIOUS PAVERS:
COLOR AND FINISH PER SEPARATE PLAN
EXISTING FENCE
EXISTING WATER MAIN (SIZE PER PLAN)
EXISTING SEWER MAIN (SIZE PER PLAN)
EXISTING GAS MAIN (SIZE PER PLAN)
PROPOSED 6" PVC PRIVATE STORM DRAIN
PIPING
PROPOSED 6" PVC SEWER LATERAL WITH
CLEANOUT (SHOWN FOR REFERENCE ONLY)
PROPOSED MODIFIED 3"X2' CURB OUTLET
(SHOWN FOR REFERENCE ONLY)
PROPOSED 6" AREA DRAIN (BY NDS OR
APPROVED EQUAL)
PROPOSED 24"X24" BROOKS BOX W/
STORMTEK PIPE SCREEN CONNECTOR
PCC RIBBON GUTTER
64
64
DWG 538-7
SDRSD G-2*
290 LF
5300 SF
SDRSD G-1*
1,115 SF
DWG 538-7 1 EA
SDRSD C-03 265 SF
175 LF
260 LF
290 LF
1 EA
11 EA
100 LF
1,020 SF
N/A
AM
GRADING NOTES STREET NOTES
WORK TO BE DONE
Y\ (
\ .
/ -,/
• ' •
•
• LEGAL DESCRIPTION • LEGEND •
• DESCRIPTION STD. SYMBOL QUANTITY --VICINITY MAP -
OWNER'S CERTIFICATE
BENCH MARK ----------
[~~:~~
..
BASIS OF BEARINGS
PROJECT ADDRESS
ABBREVIATION LEGEND
SOURCE OF TOPOGRAPHY REFERENCE DRAWINGS
-
INDEX OF SHEETS V\2S.X x 5< SJ
I . .
EROSION CONTROL NOTES PROJECT LOCATION IS<2'<2S<6::<I
'
w w
' '
EARTHWORK gUANTITIES
OWNER INFORMATION DEVELOPER
SD SD
s s 0
DISTURBED AND IMPERVIOUS AREA ---------------------
ABANDONMENT NOTES a
□
------------
SOILS ENGINEER'S CERTIFICATE
~ ~i_ ~iofESSio,t,
<;:) .,,( ~ ~'-~-C[,p ~ ~/ :::? ,.; ;po~ PASCO LARET SUITER ½""!i JI;;..,-:
i,; GE 2007 ~ ~ ~ = "' & ASSOCIATES
DECLARATION OF RESPONSIBLE CHARGE (SHEETS 1-7) * EXP. 9/30/.zl * San Diego I Solana Beach I Orange County
~0T[CH1'\\C~~ Phone 858.259.8212 I www.plsaengineering.com
tor r.H.,,0
I SHEET 11 CITY OF CARLSBAD 11 SHEETS I
-
~ ~ ~
GRADING PLANS FOR: dfs? --'?"of ESS Io½
{5> ~ ~1'\DR[Jr1; < -"<' ,f,_~ !:? j:-'t,; ~ 111LE SHEET V')Qj ,-t>--z APPROVED: JASON S. GELDERT ~ No. 86542 ~
"" Exp. 03/31 /25 °"
* * ENGINEERING MANAGER RCE 63912 EXPIRES 9/30/24 DAlE
J'~lf CIVIL (!;*°"' DWN BY:
I
I DRAWING NO. PROJECT NO. DAlE INITIAL DAlE INITIAL DAlE INITIAL OF CALI' REVISION DESCRIPTION CHKD BY:
ENGINEER OF WORK OlHER APPROVAL CITY APf'ftOVAL RVWD BY:
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
X
XXXXXX
X
X
X
XXXXX
X
X
X X X
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 1 STORY
BUILDING
EXISTING 1 STORY
BUILDING
EXISTING 1 STORY
BUILDING
SHED
3' WOOD FENCE
8' WROUGHT IRON
FENCE
6' WOOD FENCE6' WOOD FENCE6' WOOD FENCE
6' WOOD FENCE 6' WOOD FENCE
6' WOOD FENCE
3' WOOD FENCE
6' WOOD FENCE
X
X
X X X X
53
53
52
52
52
52
52
51
51
51
5
1
51
50
50
50
50
50
49
49
49
49 49
49
48
48 48
48
48 48
48
4
8
47
47
47
47 47 47
47
46
46
46 46
46
45
4545
45
44
44
44
44
43
42
FL=48.49
FL=48.27
FL=47.40
FL=46.20
FL=46.14
FL=45.30
FL=44.59
FL=44.45
FL=43.98
FL=43.34
FL=42.92
FL=42.66
TC=48.95
TC=48.74
TC=47.85
TC=46.26
TC=46.68
TC=45.38
TC=44.74
TC=44.90
TC=44.14
TC=43.48
TC=43.08
TC=43.11
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
COMM POST
SI
D
E
W
A
L
K
DR
I
V
E
W
A
Y
EN
T
R
A
N
C
E
DR
I
V
E
W
A
Y
EN
T
R
A
N
C
E
WA
L
K
W
A
Y
WALKWAY
WALKWAYWA
L
K
W
A
Y
PATIO
PATIO
BLDG OVERHANG
BLDG OVERHANG
42.7 42.3 42.7
42.8 42.7 43.4
45.9
46.747.247.748.2
48.5
48.5
48.8
48.8
48.7
49.4 49.4
49.4
49.4
49.5
49.1 49.1
49.4
49.5
49.4
49.7
49.4
49.4
49.4
49.3
49.3
49.4
49.4
49.2
48.9
49.0
51.4
51.3
51.5
51.4
51.3 51.2
51.2
51.8
51.6
51.2
50.8
50.4
49.7
49.4
48.7
48.3 48.6
48.3
52.3
52.5
52.3
52.6 52.2
52.2
51.5
51.3
51.7
51.4
51.7
51.3
51.8
51.4
51.6
51.5
50.5
50.7
50.3
50.6
50.3
50.7
50.3
50.8
50.4
50.6
50.2
49.7
49.2
49.8
49.3
49.6
49.4
49.8
49.3
49.7
49.2
49.7
48.7
48.7
48.7
48.7
48.6 48.5
51.8
47.2
47.6
49.4
OE
OE
OE
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXX
344 CHINQUAPIN AVE
APN 206-020-27-00350 CHINQUAPIN AVE
APN 206-020-34-00
306 CHINQUAPIN AVE
APN 206-020-12-00
N 34°00'09" W 274.76'
N 34°00'09" W 274.78'
N
5
5
°
5
8
'
2
7
"
E
7
0
.
0
0
'
N
5
5
°
5
9
'
0
3
"
E
7
0
.
0
0
'
25.0'25.0'
CH
I
N
Q
U
A
P
I
N
A
V
E
50.0'
1
1
2
3
4
5
5
6
6
6
7
7
2
113
23
2
2
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
W W W
G G G G
S
S
S
S
W
SSS
9
2
10
10
10
10
10
10 10
11
11
1212
11
12
12
11
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
BAK
PA
S
C
O
,
L
A
R
E
T
,
S
U
I
T
E
R
&
A
S
S
O
C
I
A
T
E
S
19
1
1
S
A
N
D
I
E
G
O
A
V
E
N
U
E
,
S
A
N
D
I
E
G
O
,
C
A
9
2
1
1
0
PH
:
(
8
5
8
)
2
5
9
-
8
2
1
2
F
A
X
:
(
8
5
8
)
2
5
9
-
4
8
1
2
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
PUD 2021-0010
CT 2021-0005
13
538-7A
GR 2022-0029
2
GRAPHIC SCALE: 1" = 10'
0 10 20 30
PLAN VIEW - DEMO PLAN
SCALE: 1" = 10' HORIZONTAL
PLSA 3729J:\ACTIVE JOBS\3729 RINCON 330 CHINQUAPIN\CIVIL\DRAWING\GRADING PLANS\3729-CV-GP-02-DEMO.DWG
DEMO PLAN
DEMO NOTES
1 EXISTING SURVEY MOMUMENT TO REMAIN; SEE NOTE 4
THIS SHEET
EXISTING WALL TO BE REMOVED
EXISTING FENCE TO BE REMOVED
EXISTING PAVERS TO BE REMOVED
EXISTING STRUCTURE TO BE REMOVED
EXISTING PCC HARDSCAPE TO BE REMOVED
2
3
4
5
EXISTING GAS SERVICE TO BE REMOVED PER SEPARATE
SDGE WORK ORDER; SEE NOTE 1 THIS SHEET.
EXISTING OFFSITE STRUCTURE TO REMAIN
EXISTING WALL TO REMAIN
EXISTING OFFSITE FENCE TO REMAIN
9
10
6
11
12
1. CONTRACTOR TO KILL EXISTING GAS SERVICES
PRIOR TO DEMOLITION OF ANY STRUCTURES
2. CLEAR AND GRUB EXISTING ONSITE VEGETATION;
DISPOSE OF ANY EXISTING ONSITE DEBRIS.
3. EXISTING SEWER LATERAL LOCATION SHOWN
HEREON; REMOVED AND CAP AT THE MAIN.
4. EXISTING SURVEY MONUMENTS SHALL BE
PROTECTED IN PLACE. MONUMENT(S) DISTURBED OR
DESTROYED SHALL BE REPLACED BY A LICENSED
LAND SURVEYOR WHO SHALL FILE A CORNER
RECORD WITH THE COUNTY.
ADDITIONAL NOTES
LEGEND
PROPERTY BOUNDARY
CENTERLINE OF ROAD
ADJACENT PROPERTY LINE
PUBLIC RIGHT-OF-WAY
EXISTING CONTOUR LINE
EXISTING FENCE
EXISTING WATER MAIN (SIZE PER PLAN)
EXISTING SEWER MAIN (SIZE PER PLAN)
EXISTING GAS MAIN (SIZE PER PLAN)
EXISTING CMU RETAINING WALL
EXISTING BUILDING FOOTPRINT
AM
I
I
I
I
I X
I
I
I
I
I
I
--------
----64 ------X--X-----w--w----S S ----G G --
0
0
0
0
0
0
X
X
X
0
0
0
0
-------
X
I
I
-I
I
I
I
I
X I I
I
X L __
I
I
I
I
I I
I I
I I
/ .......... ..... / .....
--fr ..... .....
~ ··~ ...... 1..:
' ~
X
•
-
. • A • •
• •
•
.,,,-0 • "' • • .
X ,
..... .....
II
'
I
X I
I
I
X
X
. vx
I ,1
I
I X •
·x . .
. /
~,
I
I
•
X
~
1-..:. . I A-
I I •
I
T
I • I -
X
.
' -I. --
. . L. .. _.,
I
I 0
• • A
•
"' .
•
• .
"' • • . •
• "' •
II
X
X
• A • '· • ' . ' • •
• • A • •
• • •
.....
0---------I
X I
I X
I
------
"'--o X
X
X
X
X
\
\
\
I
•
__ .1....---
•
•
'
-----------
PASCO LAREY SUITER
& ASSOCIATES
San Diego I Solana Beach I Orange County
Phone 858.259.8212 I www.plsaengineering.com
---
I
I
• -t-
;\
I I
1----1--+---------------t-----;---;---r-~~II CITY OF CARLSBADILJ
GRADING PLANS FOR:
APPROVED: JASON S. GELDERT
ENGINEERING MANAGER RCE 63912 EXPIRES 9 30 24 DAlE
DA 1E INlllAL
ENGINEER OF WORK
DA 1E INlllAL DAlE INlllAL
REVISION DESCRIPTION DlHER APPROVAL CITY APf'ftOVAL
DWN BY: __ _
CHKD BY: __ _
RVWD BY:
PROJECT NO. I DRAWING NO.
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
X
XXXXXX
X
X
X
XXXXX
X
X
X X X
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 1 STORY
BUILDING
EXISTING 1 STORY
BUILDING
EXISTING 1 STORY
BUILDING
SHED
3' WOOD FENCE
8' WROUGHT IRON
FENCE
6' WOOD FENCE6' WOOD FENCE6' WOOD FENCE
6' WOOD FENCE 6' WOOD FENCE
6' WOOD FENCE
3' WOOD FENCE
6' WOOD FENCE
X
X
X X X X
53
53
52
52
52
52
52
51
51
51
5
1
51
50
50
50
50
50
49
49
49
49 49
49
48
48 48
48
48 48
48
4
8
47
47
47
47 47 47
47
46
46
46 46
46
45
4545
45
44
44
44
44
43
42
FL=48.49
FL=48.27
FL=47.40
FL=46.20
FL=46.14
FL=45.30
FL=44.59
FL=44.45
FL=43.98
FL=43.34
FL=42.92
FL=42.66
TC=48.95
TC=48.74
TC=47.85
TC=46.26
TC=46.68
TC=45.38
TC=44.74
TC=44.90
TC=44.14
TC=43.48
TC=43.08
TC=43.11
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
COMM POST
SI
D
E
W
A
L
K
DR
I
V
E
W
A
Y
EN
T
R
A
N
C
E
DR
I
V
E
W
A
Y
EN
T
R
A
N
C
E
WA
L
K
W
A
Y
WALKWAY
WALKWAYWA
L
K
W
A
Y
PATIO
PATIO
BLDG OVERHANG
BLDG OVERHANG
42.7 42.3 42.7
42.8 42.7 43.4
45.9
46.747.247.748.2
48.5
48.5
48.8
48.8
48.7
49.4 49.4
49.4
49.4
49.5
49.1 49.1
49.4
49.5
49.4
49.7
49.4
49.4
49.4
49.3
49.3
49.4
49.4
49.2
48.9
49.0
51.4
51.3
51.5
51.4
51.3 51.2
51.2
51.8
51.6
51.2
50.8
50.4
49.7
49.4
48.7
48.3 48.6
48.3
52.3
52.5
52.3
52.6 52.2
52.2
51.5
51.3
51.7
51.4
51.7
51.3
51.8
51.4
51.6
51.5
50.5
50.7
50.3
50.6
50.3
50.7
50.3
50.8
50.4
50.6
50.2
49.7
49.2
49.8
49.3
49.6
49.4
49.8
49.3
49.7
49.2
49.7
48.7
48.7
48.7
48.7
48.6 48.5
51.8
47.2
47.6
49.4
OE
OE
OE
OE
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXX
W W W W
WM
WM W W W
W W W
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
S S S S S S S S S
W W W
SD
SD
SD
SD
SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD
G G G G
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
SSS
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
XXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
XXXX
X
X X
XX
X X
X X
X
(49.0)
FG
(48.8)
FG
(48.5)
FG
(48.2)
FG
48.2 TW@EG
47.5 TW@FS
(46.3 BW@FG)
(48.7 TW@EG)
47.3 TW@FG
(45.8 BW@EG)
(48.4 TW@EG)
47.0 TW@FS
(45.6 BW@EG)
(53.4)
FG
(53.8)
FG
(54.0)
FG
(54.2)
FG
(54.3)
FG
(54.3)
FG
(54.3)
FG
(54.1) FG(54.3)
FG
GFF = 50.0 GFF = 50.0
GFF = 49.0 GFF = 49.0 GFF = 49.0 GFF = 48.2 GFF = 48.2 GFF = 48.2
UNIT 1
FF= 48.7
PAD= 48.2
UNIT 2
FF= 48.7
PAD= 48.2
UNIT 3
FF= 48.7
PAD= 48.2
UNIT 4
FF= 49.5
PAD= 49.0
UNIT 5
FF= 49.5
PAD= 49.0
UNIT 6
FF= 49.5
PAD= 49.0
UNIT 7
FF= 50.5
PAD= 50.0
UNIT 8
FF= 50.5
PAD= 50.0
UNIT 9
FF= 50.5
PAD= 50.0
49.52 FS 49.29 FS 48.5 FS 48.51 TC
48.01 FL 46.9 TC
46.4 FL
45.97 TC
45.47 FL
49.40 FL
49.17 FL
48.32 FL
49.46 FS
49.40
FS
49.31 FS
49.22 FS49.42 FL
49.55 FL
49.60 FL
49.8 FG/HP
49.6 FL
50.0 FG
50.0 FG
49.5 FG 48.8 FL
49.92 FS
49.96 FS 49.90 FS
50.00
FS 50.00 FS
49.85 FS
49.82 FS
48.81 FS
49.72 FS
48.66 FS
49.68 FS
48.42 FS
49.63 FS
49.35 FS 49.11 FS
48.84 FS
48.09 FS
48.78 FS
48.15 TC
47.65 FL
47.85 FS
48.80 FS
47.95 TC
47.45 FL
48.74 FS
48.72 FS
47.40 FS 47.3 FS
48.67 FS
48.42 FS
48.20 FS 47.94 FS
47.0 FS
46.8 FS
47.90 FS
47.89 FS 47.85 FS
46.75 FS 46.6 FS 46.5 FS 46.3 FS
47.82 FS 47.78 FS
47.55 TC
47.05 BC
3.
7
%
3.
7
%
0.
5
%
0.
6
%
4.
1
%
4.
6
%
4.
6
%
7.
9
%
7.
9
%
7.
0
%
7.
0
%
9.
3
%
9.
3
%
4.
0
%
4.
0
%
5.
1
%
5.
1
%
5.
4
%
5.
4
%
6.
5
%
6.
5
%
7.
1
%
7.
1
%
8.
2
%
8.
2
%
6.
4
%
6.
4
%
7.
5
%
7.
5
%
7.
8
%
7.
7
%
8.
8
%
8.
8
%
9.
5
%
9.
5
%
10
.
6
%
10
.
6
%
7.
9
%
1.0%
0.4%
0.4%
0.4%
0.4%
3.0%
0.3%
0.3%
0.3%
0.3%
0.3%
2.8%
0.3%
0.3%0.3%
0.3%4.6%
0.3%
1.5%1.5%1.0%
6.0%
1.0%1.0%1.5%1.0%1.
5
%
1.
5
%
1.
5
%
5.0%
1.
3
%
1.
6
%
1.
0
%
1.
0
%
0.9
%
1.0%
1.
0
%
0.
9
%
1.
0
%
1.0%1.0%1.0%1.0%1.0%1.0%
49.0 FG
49.0 FG
48.2 FG 48.2 FG
47.7 FG
46.9 TG
45.7 IE
48.50 FS
48.50 FS49.50 FS 49.50 FS
0.
7
%
1.4%
2.
0
%
0.
4
%
1.1%
1.
6
%
52.4 TW
(52.0 TW@FG)
50.0 BW
49.1 TF
END OF SHORING WALL
BEGIN C-3 WALL;
53.7 TW
50.0 BW@FG
49.1 TF
53.0 TW
49.0 BW@FG 53.0 TW
52.0 TW@FG
49.0 BW@FG
52.0 TW
51.4 TW@FG
48.2 BW@FG
50.0 TW
49.4 TW@FG
47.7 BW@FG
BEGIN SHORING WALL
END C-3 WALL
49.1 TW
48.7 TW@FG
47.4 BW
46.3 TF
BEGIN C-3 WALL
47.8 TW
47.8 BW
GR
A
D
E
B
R
E
A
K
10.0'
FYSB
10.0' RYSB
5.
0
'
SY
S
B
5.
0
'
SY
S
B
20
.
0
'
4.
0
'
24
.
0
'
20
.
0
'
8.5'
8.0'8.0'
24
.
0
'
15
.
0
'
24
.
0
'
15
.
0
'
20
.
0
'
4.
0
'
20
.
0
'
4.
0
'
8.5'16.5'
25.0'
5.0'
49
48
47
46
48.62 FS
5.0'
EX
.
6
"
V
C
S
W
R
@
4
.
4
%
EX
.
6
"
A
C
W
T
R
(
D
W
G
1
4
6
-
6
)
EX
.
1
2
"
A
C
W
T
R
(
D
W
G
1
5
9
-
9
)
EX
.
1
"
H
P
G
A
S
25.0' TO PL
47.1
FS
48.2 FS
48.15 FS
GFF = 50.0
48.4 TW
48.3 TW@FG
47.8 BW
46.3 TF
2
2
23
3
3
3
4 4
7
7
7 7
7
18
6
EX WALL
TO REMAIN
EX WALL
TO REMAIN
END C-3 WALL
50.0 TW
49.6 BW
49.1 TF
(53.5 TW)
(49.5 TW @ FG)
(47.1 BW @ FG)
(47.1 FS)
EX WALL
TO REMAIN
(50.7 TW)
(50.0 TW @ FG)
(47.7 BW @ FG)
(52.8 TW)
(52.1 TW @ FG)
(48.9 BW @ FG)
(49.8 FS)
(53.6 TW)
(52.9 TW @ FG)
(50.0 BW @ FG)
(54.4 TW)
(53.4 BW)4.
7
'
4.
9
'
10
.
0
'
12
.
6
'
EX PCC DWY
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
ASPHALT
TO REMAIN
EXISTING EDGE
OF ASPHALT
EXISTING EDGE
OF ASPHALT
12
12
49.5 FG
49.0 FG
48.4 FG
48.2 FG
48.4 FG
344 CHINQUAPIN AVE
APN 206-020-27-00350 CHINQUAPIN AVE
APN 206-020-34-00
306 CHINQUAPIN AVE
APN 206-020-12-00
EX WALL
TO REMAIN
EX OVERHEAD
UTILITIES TO
REMAIN
EX OVERHEAD
UTILITIES TO
REMAIN
49.4 TG
48.6 IE
49.3 TG
48.4 IE
49.0 TG
48.2 IE 48.7 TG
48.0 IE
48.4 TG
47.8 IE
48.3 TG
47.6 IE 47.9 TG
47.2 IE
47.4 TG
46.8 IE
47.2 TG
46.2 IE
47.0 TG
45.4 IE
45.9 TG
44.8 IE IN
44.7 IE OUT
SIGHT DISTANCE
L = 150 FT
(VM = 20 MPH)
CALTRANS CORNER
SIGHT DISTANCE; SEE
NOTE THIS SHEET
24
.
0
'
5.0'
16.5'
3
20
33
13
0.4%
11
11
MIN
50.0 FG
5.0
%
MI
N
53.0 TW
49.5 BW@FG
3.
3
'
5.0
%
MIN
49.5 FG
49.3 FL
49.0 FG
5.0
%
MI
N
5.0
%
MI
N
5.0
%
MI
N
5.0
%
MI
N
5.0
%
MI
N
5.
0
%
MI
N
RET. WALL
FOOTING (TYP.)48.5 FG
48.5 FG
5.0
%
MI
N
52.0 TW
51.5 TW@FG
48.5 BW@FG
5.0%
MIN
47.0 FG
50.0 TW
49.1 TW@FG
48.2 BW@FG
EX. RET. WALL
TO BE REMOVED SIGHT DISTANCE
L = 150 FT
(VM = 20 MPH)
CH
I
N
Q
U
A
P
I
N
A
V
E
(S
E
E
D
W
G
5
3
8
-
7
F
O
R
P
U
B
L
I
C
I
M
P
R
O
V
E
M
E
N
T
S
I
N
R
O
W
)
48.0 TW@EG
48.0 TW@FS
(47.0 BW@FG)
GR
A
D
E
B
R
E
A
K
GR
A
D
E
B
R
E
A
K
PROPOSED
TRANSFORMER
19
50.00 TW
49.1 TW@FG
48.2 BW@FG
5.
0
'
3.
3
'
3.
3
'
53.0 TW
49.5 BW@FG
N 34°00'09" W 274.76'
N 34°00'09" W 274.78'
N
5
5
°
5
9
'
0
3
"
E
70
.
0
0
'
N
5
5
°
5
8
'
2
7
"
E
70
.
0
0
'
48.7 TC
48.2 FS 48.7 TC
48.2 FS48.7 TC
48.2 FS
48.7 TC
48.2 FS
48.7 TC
48.2 FS48.7 TC
48.2 FS
49.5 TC
49.0 FS
50.5 TC
50.0 FS
50.5 TC
50.0 FS 50.5 TC
50.0 FS
50.5 TC
50.0 FS
50.5 TC
50.0 FS 49.5 TC
49.0 FS
49.5 TC
49.0 FS49.5 TC
49.0 FS
49.5 TC
49.0 FS
49.5 TC
49.0 FS
49.86 TC
49.36 FS
49.94 TC
49.44 FS50.43 TC
49.93 FS
DEEPEN PCC C&G AS
NECESSARY BENEATH
EXISTING SLOPE
16
18
18 18 18 18 18
18 18
PROPOSED WALL AND FENCE
COMBINATION NOT TO EXCEED 6'
PROPOSED FENCE
NOT TO EXCEED 6'
50.3 FS
50.3 FS 50.3 FS
49.3 FS 49.3 FS 49.3 FS 48.7 FS 48.7 FS
1488
22
21
46.0 TG
44.9 IE
47.4 TG
45.3 IE
46.3 RIM
44.6 IE
23
24
25
24
25
24
25
24
25
25
24
25
24
9
GRAPHIC SCALE: 1" = 10'
0 10 20 30
PLAN VIEW - GRADING PLAN
SCALE: 1" = 10' HORIZONTAL
GENERAL NOTES
1. ALL UTILITIES SHOWN HEREON PER BEST AVAILABLE RECORD
INFORMATION.
2. ALL EXISTING ONSITE STRUCTURES TO BE DEMOLISHED UNLESS
OTHERWISE NOTED.
3. ALL EXISTING ONSITE TREES TO BE REMOVED UNLESS OTHERWISE NOTED.
4. ALL ONSITE WATER, SEWER, AND STORM DRAIN FACILITIES TO BE
PRIVATELY MAINTAINED.
5. HARDSCAPE SHALL DRAIN AWAY FROM PROPOSED STRUCTURES AT
MINIMUM OF 2.0% FOR 10 FEET, AND LANDSCAPE FOR A MINIMUM OF 5.0%
IN ACCORDANCE WITH THE 2016 CALIFORNIA BUILDING CODE SECTION
1804.4. ANY DEVIATION SHALL REQUIRE RECOMMENDATION FROM
PROJECT GEOTECHNICAL ENGINEER.
CONSTRUCTION NOTES
1 CONSTRUCT MASONRY RETAINING WALL PER SDRSD C-03
CONSTRUCT DEEPENED FOOTING PER SEPARATE PLANS
CONSTRUCT 6" PCC FLUSH CURB DEEPENED BENEATH
ADJACENT FOOTING; SEE DETAIL SHEET 4
CONSTRUCT 6" X 34" PCC FLUSH CURB
CONSTRUCT 6" PCC CURB & GUTTER SDRSD G-2
CONSTRUCT 2-FT WIDE PCC RIBBON GUTTER PER DETAIL
SHEET 4
INSTALL PERVIOUS PAVERS PER DETAIL SHEET 4
CONSTRUCT SHORING WALL PER STRUCTURAL DESIGN;
SEE SHEETS 8-13
2
3
4
5
CONNECT PERVIOUS PAVER SUBDRAIN TRUNK LINE TO
BROOKS BOX
INSTALL 12" X 18" BROOKS BOX W/ 1218 STEEL GRATE OR
APPROVED EQUAL AND REM TRITON TDAM-PERF-FTC
TDAM12(5) OR APPROVED EQUAL *TRASH CAPTURE BMP
INSTALL TREE & SILVACELL SYSTEM; SEE DETAIL SHEET 4
CONSTRUCT STEM WALL PER SEPARATE PLANS
INSTALL 6" PVC STORM DRAIN @ 0.7%
INSTALL 6" PVC STORM DRAIN @ 2.0%
CONSTRUCT 6" PCC CURB PER SDRSD G-1
EXISTING SURVEY MONUMENT TO BE PROTECTED IN
PLACE. MONUMENT(S) DISTURBED OR DESTROYED SHALL
BE REPLACED BY A LICENSED LAND SURVEYOR WHO
SHALL FILE A CORNER RECORD WITH THE COUNTY.
9
10
6
11
7
12
13
CALTRANS SIGHT TRIANGLE NOTE:
150-FT STOPPING SIGHT DISTANCE SHOWN IN
ACCORDANCE WITH CITY OF CARLSBAD STREET
DESIGN CRITERIA (TABLE A) FOR PRIVATE
DRIVEWAY CONNECTION TO LOCAL STREET, AND
CALTRANS HIGHWAY DESIGN MANUAL CHAPTER 201
EASEMENT / DEDICATION NOTES
PROPOSED 1.5' WIDE PEDESTRIAN ACCESS EASEMENT TO THE CITY
OF CARLSBAD
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
BAK
PA
S
C
O
,
L
A
R
E
T
,
S
U
I
T
E
R
&
A
S
S
O
C
I
A
T
E
S
19
1
1
S
A
N
D
I
E
G
O
A
V
E
N
U
E
,
S
A
N
D
I
E
G
O
,
C
A
9
2
1
1
0
PH
:
(
8
5
8
)
2
5
9
-
8
2
1
2
F
A
X
:
(
8
5
8
)
2
5
9
-
4
8
1
2
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
PUD 2021-0010
CT 2021-0005
13
538-7A
GR 2022-0029
PLSA 3729J:\ACTIVE JOBS\3729 RINCON 330 CHINQUAPIN\CIVIL\DRAWING\GRADING PLANS\3729-CV-GP-03-GRAD.DWG
GRADING PLAN
14
INSTALL 6" AREA DRAIN BY NDS OR APPROVED EQUAL
INSTALL 4" THICK PCC SIDEWALK PER SDRSD G-07
INSTALL 6" PVC STORM DRAIN @1.3%
CONSTRUCT 6" PCC FLUSH CURB DEEPENED 12" BELOW
BOTTOM OF PERVIOUS PAVER GRAVEL SECTION
INSTALL 8" TRENCH DRAIN BY NDS OR APPROVED EQUAL
W/ REM TRITON TDAM-PERF-FTC TDAM8(10) OR APPROVED
EQUAL *TRASH CAPTURE BMP
CONSTRUCT PCC SPILLWAY; SEE DETAIL SHEET 4
INSTALL 10" PVC STORM DRAIN @1.0% MIN.
ELECTRICAL METER PANEL PER SEPARATE BUILDING
PLANS
GAS METER PER SEPARATE BUILDING PLANS
17
18
3
19
**SHORING WALL NOTE: TW@FG AND BW@FG AS SHOWN ON THIS
SHEET FOR PERMANENT SHORING WALL DENOTES TOP OF WALL AND
BOTTOM OF WALL @ FINISHED GRADE / TO ESTABLISH LINE AND GRADE
ONLY; REFER TO WALL PROFILES ON SHEETS 9-10 FOR ACTUAL TOP OF
SHORING WALL AND SOLIDER BEAM SCHEDULE SHEET 11 FOR SOLIDER
BEAM DEPTH AND SIZE
20
21
22
23
8
15
16 24
25
SEWER NOTE:
PRIVATE SEWER SHOWN FOR REFERENCE
ONLY. SEPARATE BUILDING DEPARTMENT
PERMIT REQUIRED.
AM
X
[i]
I I
I I
I I
...__
...__
----
-~f11tfj2~;fJkirFi' ....... f-~~--------;( X f----rlL-r--L-h
I
I t _1_9_ ~~-..........
I --......__
~
I I
I
I
I
I
I
I
X
---y -
.....
--
0
0
0
0
0
0
0
0
X
----.. ..... .....
.....
.....
..... .....
X
17'}--, -
8t---~
X X
X X X
-------
-----~--
~----1 15
15
X
X -----<15
---I I ------------------•11.------...
--...
11t--,
------
-- --
_A _;1~8. .
0
0
0
0
0
0
0
0
X
17>-----,
X
0
0
0
0
0
0
0
0
0
\
\
X
L
X
------
17}-+,
' .. ;I
/ . '---A •
'-------f 8 ----;8
• • • • • , •
• ,, "' • • • ,,
• • • • , • ,
X
,,
• 10 \ • ·\ ""' •
,
•
"'
• • ,,
•
~
,
5 )---, ------II
, I . -:----/; " \;,
1t, -" _t-• ' •• • • : " /;
s
~----1 15
~
;. -. .. • '
' 1 · ~ '
'
,
15 ~ ,
X 17..::J.,
CD
,r
I .
I
I ,
17
+= ~~.
-
,, • ~~\_-----{8
• , \ '----""'",8 8 1-----
-----<8 I
I
I
I
I
I
I
I
' I
I
I
I
I
I
I
I
I
I
I·
I
·1 1 \ I ,
I
I A
I • I
\ .
' -' -
-----------
PASCO LAREY SUITER
& ASSOCIATES
San Diego I Solana Beach I Orange County
Phone 858.259.8212 I www.plsaengineering.com
\ I
I
I I
t-----+---+-----------+------+---+------+--t ~ 11 CITY OF CARLSBAD I LJ
t-------1>-----+-----------------+------t--+-----11----1 GRADING PLANS FOR:
APPROVED: JASON S. GELDERT
ENGINEERING MANAGER RCE 63912 EXPIRES 9 30 24 DAlE
DA 1E INITIAL
ENGINEER OF WORK REVISION DESCRIPTION
DA 1E INITIAL DAlE INITIAL
DlHER APPROVAL CITY APf'ftOVAL
DWN BY: __ _
CHKD BY: __ _
RVWD BY:
PROJECT NO. I DRAWING NO.
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
NOTE:
-ALL AGGREGATE MUST BE CLEAN/WASHED AND FREE OF FINES (SAND, SILT, ETC.)
-THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEEN ADDED
-EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENT OF NEXT COURSE
-NO IMPERVIOUS LINER OR FILTER FABRIC IS TO BE USED
-SPECIAL APPROVAL REQUIRED FOR USE IN HIGHLY EXPANSIVE SOIL-SUBDRAIN MAY BE REQUIRED
-PAVER INSTALLATION SHALL BE PER MANUFACTURER'S RECOMMENDATIONS; PAVER SECTION PER
GEOTECHNICAL ENGINEER RECOMMENDATIONS AND REQUIRED TO MAINTAIN IMPOSED LOADS OF
NOT LESS THAN 75,000 LBS
SOIL SUBGRADE
MIN. 6" THICK OF 34" CRUSHED ROCK
CHOKER COURSE-4" THICK OF 38" TO
12" (NO.57) CRUSHED ROCK
BEDDING COURSE-1" THICK OF 1
8" TO 3
8"
(NO.8) AGGREGATE
VOID FILLER-1
8" TO 3
8"
(NO.8)
AGGREGATE IN VOIDS
APPROVED
PERVIOUS PAVERS
W/ MIN. 3
8" VOID
6" X 16" PCC FLUSH CURB OR
DEEPENED G-1 CURB
2.0'
1.0'1.0'
PROPOSED PERVIOUS
PAVER DRIVE AISLE PER
DETAIL THIS SHEET
0.
0
5
'
FL + 0.05'
FL
PROPOSED 3' WIDE,
5" THICK PCC
RIBBON GUTTER;
560-C-3250 CONCRETE
VARIES VARIES
SUBGRADE
5"
DEEPEN RIBBON GUTTER TO EXTEND
BENEATH GRAVEL SECTION; EMBED
6" INTO COMPACTED SOILS (TYP.)
5%5%FL + 0.05'
TYPICAL DETAIL - PERVIOUS PAVERS
NOT TO SCALE
TYPICAL DETAIL - RIBBON GUTTER
NOT TO SCALE
PAVERS & SUBGRADE
PER DETAIL, THIS SHEET
WOVEN GEOTEXTILE FABRIC
SILVACELL SYSTEM
WITHIN CRITICAL ROOT ZONE AREA
(TRAFFIC RATED)
4" AGGREGATE BASE
WOVEN GEOTEXTILE FABRIC
PROPOSED TREE
PER LANDSCAPE PLAN
FG PER PLAN
ROOT BALL
PER LSCAPE
1.5' MIN
PL
NOTE:
-REFER TO LANDSCAPE PLANS FOR ALL SPECIFICATIONS & DETAILS FOR PROPOSED VEGETATION
-REFER TO SILVACELL MANUFACTURER FOR FULL DETAIL & SPECIFICATIONS FOR PRODUCT.
TYPICAL DETAIL - SILVACELL SYSTEM
NOT TO SCALE
4" PERFORATED PVC SUBDRAIN PER
GOETECH RECOMMENDATION;
CONNECT TO BROOKS BOX
6"
UNIT 2
FF= 48.7
PAD= 48.2
APPROX.
EXISTING
GRADE
47.9 FL
50.0 TW
(49.4 TW@FG)
48.0 BW @ FG
46.0 BW
5'
48.2 FG
EX BLDG
FF= 54.0±
1:1
ZONE OF
INFLUNCE
PROPOSED 6" PVC
PVT STORM DRAIN
46.6 IE
2.5'
MIN
MIN
PL
PROPOSED SHORING WALL;
SEE SHORING SHEETS 8-13; TIE
SUB DRAIN INTO PVT STORM
DRAIN OR APPROVED
DISCHARGE LOCATION
3' 2'
PROPOSED SHORING WALL; SEE
SHORING SHEETS 8-13; TIE SUB
DRAIN INTO PVT STORM DRAIN OR
APPROVED DISCHARGE LOCATION
PL
49.5 FL
APPROX. EXISTING
GRADE
5'
EX BLDG
FF= 54.0±
1:1
ZONE OF
INFLUENCE
2.5'
MIN
MIN
PROPOSED 6" PVC
PVT STORM DRAIN
48.6 IE
UNIT 8
FF= 50.5
PAD= 50.0
50.0 FG
EXISTING WALL
TO BE REMOVED
EXISTING WALL
TO REMAIN
53.0 TW
49.6 BW@FG
48.0 BW
3' 2'
X
X
X
EXISTING 2 STORYBUILDING
EXISTING 2 STORYBUILDING
EXISTING 2 STORYBUILDING
EXISTING 2 STORYBUILDING
EXISTING 1 STORY
BUILDING
EXISTING 1 STORYBUILDING
EXISTING 1 STORYBUILDING
SHED
3' WOOD FENCE
8' WROUGHT IRONFENCE6' WOOD FENCE6' WOOD FENCE6' WOOD FENCE
6' WOOD FENCE 6' WOOD FENCE
6' WOOD FENCE
3' WOOD FENCE
6' WOOD FENCE
X
53
53
52
52
52
52
52
51
51
51
51
51
50
50
50
50
50
49
49
49
49 49
49
48
48 48
48
48 48
48
48
47
47
47
47 47 47
47
46
46
46 46
46
454545
45
44
44
44
44
43
42
FL=48.27
FL=47.40
FL=46.20
FL=46.14
FL=45.30
FL=44.59
FL=44.45
FL=43.98
FL=43.34
FL=42.92
FL=42.66
TC=48.74
TC=47.85
TC=46.26
TC=46.68
TC=45.38
TC=44.74
TC=44.90
TC=44.14
TC=43.48
TC=43.08
TC=43.11
OE
OE
OE
COMM POST
SID
E
W
A
L
K
DR
I
V
E
W
A
Y
EN
T
R
A
N
C
E
DR
I
V
E
W
A
Y
EN
T
R
A
N
C
E
WA
L
K
W
A
Y
WALKWAY
WALKWAYWAL
K
W
A
Y
PATIO
PATIO
BLDG OVERHANG
BLDG OVERHANG
42.7 42.3 42.7
42.8 42.7 43.4
45.9
46.747.247.748.2
48.5
48.5
48.8
48.8
48.7
49.4 49.4
49.4
49.4
49.5
49.1 49.1
49.4
49.5
49.4
49.7
49.4
49.4
49.4
49.3
49.3
49.4
49.4
49.2
48.9
49.0
51.4
51.3
51.5
51.4
51.3 51.2
51.2
51.8
51.6
51.2
50.8
50.4
49.7
49.4
48.7
48.3 48.648.3
52.3
52.5
52.3
52.6 52.2 52.2
51.5
51.3
51.7
51.4
51.7
51.3
51.8
51.4
51.6
51.5
50.5
50.7
50.3
50.6 50.3
50.7
50.3
50.8
50.4
50.6
50.2
49.7
49.2
49.8
49.3
49.6
49.4
49.8
49.3
49.7
49.2
49.7
48.7
48.7 48.7
48.7 48.6 48.5
51.8
47.2
47.6
49.4
OE
X
X
X XXXXXXX
X
X
XXXX X X X X X X X X X X X X
X
X
X W
WM
WM
SSSSSSSS
W
W
W
W
W
W
W
W
G
G
G
G
SD SD SD SD SD SD
G
S
S
S
S
AB
B
G C
D
D
A
E
E
F
F
CG
1.5'
CONSTRUCT 18"PCC GUTTER
CURB CUT
1.5'
CONSTRUCT 18"PCC GUTTER
PL
MODIFIED 3" X 2'CURB OUTLET PERDWG 538-7;44.6 IE
INSTALL PERVIOUSPAVERS PERDETAIL THIS SHEET
INSTALL FENCE PERSEPARATE LANDSCAPEPLANS
47.05 TG
44.4 IE
CURB CUTCONCRETE SPILLWAY
6" PCC CURB
6" PCC CURB8" TRENCH DRAINW/ TDAM8(10)-PERF
12" X 18" BROOKS BOX W/TDAM12(5)-PERF SEE DETAILTHIS SHEET;45.9 TG44.8 IE IN44.7 IE OUT
10" PVC PIPE@1.0% MIN.
46.0 TG44.9 IE
47.4 TG45.3 IE
3.5'
46.9 TC46.4 FL
45.97 TC45.47 FL
46.1 TC45.6 FL
46.7 TC46.2 FL
6.0%
UNIT 9
FF= 50.5
PAD= 50.0
PL
19'
APPROX. EXISTING
GRADE
49.8FS
49.79 FL
50.0 FG
(52.8 TW)
(48.9 BW)
52.0 TW
50.0 BW
PROPOSED MASONRY
RETAINING WALL PER
SDRSD C-03; SEE
TYPICAL DETAIL THIS
SHEET
PROPOSED DEEPENED
FOOTING PER
SEPERATE PLAN
1.0'
CLROW
16.5'
25.0'
8.5' PKWY
PROPOSED PCC
SIDEWALK
PROP. 6" PCC CURB &
GUTTER
2% MAX VARIES
5.5'3.0'
8.5' PKWY 16.5'
VARIES VARIES
25.0'
EXISTING PCC
SIDEWALK TO
REMAIN
EXISTING 6" PCC
CURB & GUTTER TO
REMAIN
EX. 1" HP GAS
EX. 6" VC SWR
(DWG 146-6)EX. 12" AC WTR
(DWG 159-9)
EX. 6" AC WTR
(DWG 146-6B)
ROW
PROJECT
SITE
2" GRIND &
OVERLAY
4" AC OVER 6" BASE
SEE DETAIL,
THIS SHEET
1.5' PROP
PED ESMT
FENCE PER SEPARATE LANDSCAPE
PLANS; COMBINED WALL AND FENCE
HEIGHT NOT TO EXCEED 6' FROM
LOWEST ADJACENT GRADE
TW PER PLAN = TOP OF
WALL AT FINISH SURFACE
0.5' MIN COVER OVER
FOOTING PER SDRSD TYP.
BW PER PLAN = BOTTOM OF
WALL AT FINSIHED GRADE
TF PER PLAN = TOP
OF FOOTING
SEALANT
*J-DRAIN
200/220
WATERPROOFING
TO TOP OF WALL
*J-DRAIN
SWD
6" X 34"
PCC FLUSH
CURB49.3 FL
49.4 FS 49.4 FS
49.5 FS
48.5 EG
Q100 DEPTH
FL + 0.10 FT
EXISTING FENCE
TO REMAIN
PL
APPROX. EXISTING
GRADE
PERVIOUS PAVER
DRIVE AISLE PER
DETAIL THIS SHEET
5.4'
1.
5
'
0.
5
'
PROPOSED FENCE PER
SEPARATE LANDSCAPE PLANS
47.3 EG
48.5 TC
48.0 FL
6" PCC CURB AND
GUTTER PER SDRSD G-2;
DEEPEN AS NECESSARY
BENEATH EXISTING
SLOPE; 5' MIN. TO
DAYLIGHT
APPROX. EXISTING
GRADE
PL
EXISTING FENCE
TO REMAIN
PERVIOUS PAVER
DRIVE AISLE PER
DETAIL THIS SHEET 2.
0
'
5.6'
PROPOSED FENCE PER
SEPARATE LANDSCAPE PLANS
47.0 EG
48.3 TC
47.8 FL
6" PCC CURB AND GUTTER
PER SDRSD G-2; DEEPEN AS
NECESSARY BENEATH
EXISTING SLOPE; 5' MIN. TO
DAYLIGHT
APPROX. EXISTING
GRADE
PL
EXISTING FENCE
TO REMAIN
PERVIOUS PAVER
DRIVE AISLE PER
DETAIL THIS SHEET
2.
0
'
6.3'
PROPOSED FENCE PER
SEPARATE LANDSCAPE PLANS
UNIT 1
FF= 48.9
PAD= 48.2
PL
47.2 FL
10'
48.2 FG
47.8
TW/BW
MASONRY RETAINING
WALL PER SDRSD
C-02; SEE TYPICAL
DETAIL THIS SHEET
PROPOSED DEEPENED
FOOTING PER
SEPERATE PLAN
APPROX. EXISTING
GRADE
FF= PER PLAN
PAD= PER PLAN
PROPOSED PERVIOUS
PAVERS; SEE DETAIL
THIS SHEET
6" FLUSH CURB DEEPENED
BENEATH BOTTOM OF PAVERS
%= PER
PLAN
4" PCC DRIVEWAY WITH
DEEPENED EDGE EXTENDING
BENEATH BOTTOM OF PAVERS
4.0'3.5'
7.5'
STANDARD FOOTING
EMBEDMENT DEPTH PER
GEOTECH RECOMMENDTATION
1.0'
45
X X X X X X X X X X X
SD
1.
5
'
CONSTRUCT 18"
PCC GUTTER
CURB CUT
1.5
'
CONSTRUCT 18"
PCC GUTTER
PL
MODIFIED 3" X 2'
CURB OUTLET PER
DWG 538-7;
44.6 IE
INSTALL PERVIOUS
PAVERS PER
DETAIL THIS SHEET
INSTALL FENCE PER
SEPARATE LANDSCAPE
PLANS
CURB CUT
CONCRETE SPILLWAY
6" PCC CURB
6" PCC CURB
8" TRENCH DRAIN
W/ TDAM8(10)-PERF
12" X 18" BROOKS BOX W/
TDAM12(5)-PERF SEE DETAIL
THIS SHEET;
45.9 TG
44.8 IE IN
44.7 IE OUT
10" PVC PIPE
@1.0% MIN.
46.0 TG
44.9 IE
3.5'
46.9 TC
46.4 FL
45.97 TC
45.47 FL
46.1 TC
45.6 FL
46.7 TC
46.2 FL
6.0%
OVERFLOW
FLOW OUT OF 12" X
18" BROOKS BOX TO
D-25 CURB OUTLET
3"
FLOW INTO 12" X 18"
BROOKS BOX FROM
TRENCH DRAIN
MOUNTING TABS
TDAM12(5) PERF - FTC;
3 INCHES FROM EXIT
PIPE
GRATED INLET
12" X 18" BROOKS BOX
WITH GRATED INLET
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
BAK
PA
S
C
O
,
L
A
R
E
T
,
S
U
I
T
E
R
&
A
S
S
O
C
I
A
T
E
S
19
1
1
S
A
N
D
I
E
G
O
A
V
E
N
U
E
,
S
A
N
D
I
E
G
O
,
C
A
9
2
1
1
0
PH
:
(
8
5
8
)
2
5
9
-
8
2
1
2
F
A
X
:
(
8
5
8
)
2
5
9
-
4
8
1
2
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
PUD 2021-0010
CT 2021-0005
13
538-7A
GR 2022-0029
SECTION CUT A-A
NOT TO SCALE
SECTION CUT B-B
NOT TO SCALE
KEY MAP
NOT TO SCALE
SECTION CUT G-G
NOT TO SCALE
TYPICAL SECTION - CHINQUAPIN AVE
NOT TO SCALE
TYPICAL DETAIL - RETAINING WALL
NOT TO SCALE
SECTION CUT D-D
NOT TO SCALE
SECTION CUT E-E
NOT TO SCALE
SECTION CUT F-F
NOT TO SCALE
4
SECTIONS & DETAILS
PLSA 3729J:\ACTIVE JOBS\3729 RINCON 330 CHINQUAPIN\CIVIL\DRAWING\GRADING PLANS\3729-CV-GP-04-SECT&DETS.DWG
SECTION CUT C-C
NOT TO SCALE
TYPICAL DETAIL - FLUSH CURB
NOT TO SCALE
TYPICAL DETAIL - GUTTER BROOKS BOX
NOT TO SCALE
*NOTE: PAVER SUBGRADE TO BE COMPACTED
TO 95% FOR THE UPPER 6" OF THE FINISHED
SUBGRADE AND AGGREGATE BASE LAYER
*J-DRAIN TO TIE INTO PRIVATE
STORM DRAIN SYSTEM OR
APPROVED DISCHARGE LOCATION
TYPICAL DETAIL - BROOKS BOX W/ TDAM 12(5) PERF FTC
NOT TO SCALE
AM
--l -
-
"' i-,4c--~-71 . • . . . . . • . . . . . . "' ~ 1/) '/.:::«_~~;--,_Y, . ;, ::---::
~ffe~w~~~ 'I~
11__.::::y--:::z, ~ ~
I
I
I
7
I
L_____I(
X
: f,-r;:6,,=:.n,=
I -
-...,..-L ....... ----
17
--------------·--------
' --
\
I
J
... ::; _ _. .. ·:."·· .. -.;: .. · . . . .......... ::::.. .. ·._,...· . . :-;_: ... •. :-... : .•:. :.·::. 1: ...... • .....
I I i:· I . . , _____ ...$11-t:r' ~..,.y,J-:::i,
-he'~~ \------
PASCO LAREY SUITER
. & ASSOCIATES
San Diego I Solana Beach I Orange County
Phone 858-259,8212 I www.plsaengineering.com
~===t==1==================f==~==~==3~=3~11 CITY OF CARLSBAD ILJ
~l-~====~1======i~==========-=-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_--1-l_--==~1=====~4=====~1===~j GRADING PLANS FOR:
~===j===±=======================~E===f==~f===f==j ~A~PP~RIO'OVE~o:=======J=;=;AS=::ON~s==. ===oao====E=RTJ
tt;D~A1E~ji1N~ITIAl.i1====~~=================~~~:=E::=t~:=t==j ENGINEERING MANAGER RCE 63912 EXPIRES 9 30 24 DAlE
RE
DAlE INITIAL DAlE DWN BY: I PRO r
ENGINEER OF WORK VISION DESCRIPTION INITIAL CHKD BY: =CT NO. I DRAWING NO.
OlHER APPROVAL CITY APf'ftOVAL RVWD BY:
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
G
A
R
F
I
E
L
D
S
T
CHIN
Q
U
A
P
I
N
A
V
E
H
I
G
H
W
A
Y
1
0
1
SITETAM
A
R
A
C
K
A
V
E
ENGINEERING DEPARTMENT
BAK
PA
S
C
O
,
L
A
R
E
T
,
S
U
I
T
E
R
&
A
S
S
O
C
I
A
T
E
S
53
5
N
.
H
W
Y
1
0
1
,
S
U
I
T
E
A
,
S
O
L
A
N
A
B
E
A
C
H
,
C
A
9
2
0
7
5
PH
:
(
8
5
8
)
2
5
9
-
8
2
1
2
F
A
X
:
(
8
5
8
)
2
5
9
-
4
8
1
2
PUD 2021-0010
CT 2021-0005
13
GR 2022-0029
PLSA 3729
5
J:\ACTIVE JOBS\3729 RINCON 330 CHINQUAPIN\CIVIL\DRAWING\GRADING PLANS\3729-CV-GP-05-SWPPP COVER.DWG
N.T.S.
THE DEVELOPER SHALL DEPLOY STANDBY BEST MANAGEMENT PRACTICE MEASURES TO
COMPLETELY PROTECT THE EXPOSED PORTIONS OF THE SITE WITHIN 48 HOURS OF A
PREDICTED STORM EVENT ( A PREDICTED STORM EVENT IS DEFINED AS A FORECASTED, 40%
CHANCE OF RAIN BY THE NATIONAL WEATHER SERVICE), IN ADDITION TO BMPs IMPLEMENTED
YEAR-ROUND INCLUDING PERIMETER CONTROL, WIND EROSION CONTROL, TRACKING,
NON-STORM WATER CONTROL, WASTE MANAGEMENT, AND MATERIALS POLLUTION CONTROL.
THE NATIONAL WEATHER SERVICE FORECAST SHALL BE MONITORED AND USED BY
THE DEVELOPER ON A DAILY BASIS. IF PRECIPITATION IS PREDICTED (40% CHANCE OF
RAIN), THEN THE NECESSARY WATER POLLUTION CONTROL PRACTICES SHALL BE DEPLOYED
WITHIN 48 HOURS AND PRIOR TO THE ONSET OF THE PRECIPITATION.
THE DEPLOYMENT OF THE BMPS SHALL INCLUDE BUT NOT BE LIMITED TO GRAVEL BAGS AND
SILT FENCES. A MINIMUM OF 125% OF THE MATERIAL NEEDED TO INSTALL STANDBY BEST
MANAGEMENT PRACTICES MEASURES TO PROTECT THE EXPOSED AREAS FORM EROSION AND
PREVENT SEDIMENT DISCHARGES MUST BE STORED ON-SITE. AREAS THAT HAVE ALREADY
BEEN PROTECTED FROM EROSION USING PHYSICAL STABILIZATION OR ESTABLISHED
VEGETATION STABILIZATION BMPS AS DETERMINED BY THE CITY OF CARLSBAD ARE NOT
CONSIDERED TO BE "EXPOSED" FOR THE PURPOSES OF "WEATHER TRIGGERED ACTION PLAN".
AN ADEQUATE SOURCE OF EQUIPMENT AND WORKERS SHALL BE AVAILABLE FOR
DEPLOYMENT OF "WEATHER TRIGGERED BMPS".
THE FOLLOWING GENERAL SITE MANAGEMENT REQUIREMENTS SHALL BE ADHERED TO
9. ALL EXPOSED DISTURBED AREAS MUST HAVE EROSION PROTECTION BMPs PROPERLY
10. ADEQUATE PERIMETER PROTECTION BMPs MUST BE INSTALLED AND MAINTAINED AND
11. ADEQUATE SEDIMENT CONTROL BMPs MUST BE INSTALLED AND MAINTAINED.
12. ADEQUATE BMPs TO CONTROL OFFSITE SEDIMENT TRACKING MUST BE INSTALLED AND
MAINTAINED.
13.A MINIMUM OF 125% OF THE MATERIAL NEEDED TOO INSTALL STANDBY BMPs TO
PROTECT THE EXPOSED AREAS FROM EROSION AND PREVENT SEDIMENT DISCHARGES,
MUST BE STORED ONSITE. AREAS ALREADY PROTECTED FROM EROSION USING PHYSICAL
14. THE OWNER/DEVELOPER/CONTRACTOR MUST FOLLOW "WEATHER TRIGGERED" ACTION
PLAN AND BE ABLE TO DEPLOY STANDBY BMPs TO PROTECT THE EXPOSED PORTIONS OF
15. DEPLOYMENT OF PHYSICAL OR VEGETATION EROSION CONTROL BMPs MUST COMMENCE
AS SOON AS SLOPES ARE COMPLETED. THE OWNER/DEVELOPER/CONTRACTOR MAY NOT RELY
ON THE ABILITY TO DEPLOY STANDBY BMP MATERIALS TO PREVENT EROSION OF SLOPES THAT
16. THE AREA THAT CAN BE CLEARED, GRADED, AND LEFT EXPOSED AT ONE TIME IS
17. ALL DISTURBED AREAS THAT ARE NOT COMPLETED AND/OR NOT BEING ACTIVELY GRADED
MUST BE FULLY PROTECTED FROM EROSION IF LEFT FOR 14 OR MORE DAYS. THE ABILITY
18. BMPs MUST BE STOCKPILED AT VARIOUS LOCATION THROUGHOUT THE PROJECT SITE
THROUGHOUT THE YEAR. WHENEVER THERE IS A 40% CHANCE OR GREATER OF A RAIN
19. ALL TREATMENT AND EROSION CONTROL BMPs MUST BE INSPECTED WEEKLY AND
PRIOR TO A FORECASTED RAIN EVENT OF GREATER THAN 50%, AND AFTER A RAIN EVENT.
20.IF SELECTED BMP FAILS DURING A RAIN EVENT, IT MUST BE REPAIRED OR IMPROVED
OR REPLACED WITH AN ACCEPTABLE ALTERNATE AS SOON AS IT IS SAFE TO DO SO. THE
FAILURE OF A BMP INDICATES IT WAS NOT ADEQUATE FOR THE CIRCUMSTANCES IN WHICH
IT WAS USED. REPAIRS AND REPLACEMENT MUST THEREFORE PUT A MORE ROBUST BMP
MEASURE IN PLACE.
21. ALL CONSTRUCTION EMPLOYEES MUST BE TRAINED ON THE IMPORTANCE OF STORM
WATER POLLUTION PREVENTION AND BMP MAINTENANCE.
1. ALL PERMANENT AND TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION SHALL
BE INSTALLED AND MAINTAINED AS REQUIRED IN SECTION 212 OF THE STANDARD
SPECIFICATIONS AND THE FOLLOWING:
A HYDROSEEDING SHALL BE APPLIED TO:
1 ALL SLOPES THAT ARE GRADED 6:1 (HORIZONTAL TO VERTICAL) OR
STEEPER WHEN THEY ARE:
a. THREE FEET OR MORE IN HEIGHT AND ADJACENT TO PUBLIC
WALL OR STREET.
b. ALL SLOPES 4 FEET OR MORE IN HEIGHT.
2 AREAS GRADED FLATTER THAN 6:1 WHEN ANY OF THE
FOLLOWING CONDITIONS EXIST:
a. NOT SCHEDULED FOR IMPROVEMENTS (CONSTRUCTION OR
GENERAL LANDSCAPING) WITHIN 60 DAYS OF ROUGH GRADING.
b. IDENTIFIED BY THE PARKS AND RECREATION DIRECTOR AS
HIGHLY VISIBLE TO THE PUBLIC.
c. HAVE ANY SPECIAL CONDITION IDENTIFIED BY THE CITY
ENGINEER THAT WARRANTS IMMEDIATE TREATMENT.
B HYDROSEEDING AREAS SHALL BE IRRIGATED IN ACCORDANCE WITH THE
FOLLOWING CRITERIA:
1 ALL SLOPES THAT ARE GRADED 6:1 OR STEEPER AND THAT ARE:
a. THREE TO EIGHT FEET IN HEIGHT SHALL BE IRRIGATED BY HAND
WATERING FROM QUICK COUPLERS/HOSE BIBS OR A
CONVENTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER
HEADS PROVIDING 100% COVERAGE.
b. GREATER THAN 8 FEET IN HEIGHT SHALL BE WATERED BY A
CONVENTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS
PROVIDING 100% COVERAGE.
2 AREAS SLOPED LESS THAN 6:1 SHALL BE IRRIGATED AS APPROVED BY
THE CITY ENGINEER, PRIOR TO HYDROSEEDING. THE DEVELOPER SHALL
SUBMIT A PROPOSED SCHEME TO PROVIDE IRRIGATION TO THE CITY
ENGINEER. THE PROPOSAL SHALL BE SPECIFIC REGARDING THE
NUMBERS, TYPE, AND COSTS OF THE ELEMENTS OF THE PROPOSED SYSTEM.
3 IRRIGATION SHALL MAINTAIN THE MOISTURE LEVEL OF THE SOIL AT THE
OPTIMUM LEVEL FOR THE GRADING OF THE HYDROSEEDED GROWTH.
C HYDROSEEDING MIX SHALL CONSIST OF ALL OF THE FOLLOWING:
1 SEED MIX SHALL CONSIST OF NO LESS THAN:
a. 20 lbs. PER ACRE OF ROSE CLOVER
b. 20 lbs PER ACRE OF ZORRO FESCUE
c. 3lbs PER ACRE OF E SCHOOL CIA CALIFORNICA
d. 4 lbs PER ACRE OF ACHILLEA MILLEFOLIA
e.3lbs PER ACRE OF ALYSSUM (CARPET OF SNOW)
f. 1/2 lb. PER ACRE IF DIMORPHOLECA
g. ITEMS c, d, e, AND f OF THIS SUBSECTION MAY BE OMITTED ON
VISIBLE FROM EITHER A PUBLIC STREET OR RESIDENTIAL
STRUCTURES.
h. ITEM a OF THIS SUBSECTION MUST BE INOCULATED WITH A
NITROGEN FIXING BACTERIA AND APPLIED DRY EITHER BY
DRILLING OR BROADCASING BEFORE HYDROSEEDING.
i. ALL SEED MATERIALS SHALL BE TRANSPORTED TO THE JOBSITE
IN UNOPENED CONTAINERS WITH THE CALIFORNIA DEPARTMENT
OF FOOD AND AGRICULTURE CERTIFICATION TAG ATTACHED TO,
OR PRINTED ON SAID CONTAINERS.
j. NON-PHYTO-TOXIC WETTING AGENTS MAY BE ADDED TO THE
HYDROSEED SLURRY AT THE DISCRETION OF THE CONTRACTOR.
2 TYPE 1 MULCH APPLIED AT THE RATE OF NO LESS THAN 2000 lbs PER
ACRE. TYPE 6 MULCH (STRAW) MAY BE SUBSTITUTED, WHEN STRAW IS USED,
IT MUST BE ANCHORED TO THE SLOPE BY MECHANICALLY PUNCHING NO LESS
THAN 50% IF THE STRAW INTO THE SOIL.
3 FERTILIZER CONSISTING OF AMMONIUM PHOSPHATE SULFATE, 16-20-0
WITH 15% SULPHUR APPLIED AT THE RATE OF 500 lbs. PER ACRE.
D AREAS TO BE HYDROSEEDED SHALL BE PREPARED PRIOR TO HYDROSEEDING:
1 ROUGHENING THE SURFACE TO BE PLANTED BY ANY OR A
COMBINATION OF:
a. TRACK WALKING SLOPES STEEPER THAN 6:1.
b. HARROWING AREAS 6:1 OR FLATTER THAT ARE SUFFICIENTLY
FRIABLE.
2 AREAS GRADED FLATTER THAN 6:1 WHEN ANY OF THE FOLLOWING
CONDITIONS EXIST:
a. ADJUSTING THE SURFACE SOIL MOISTURE TO PROVIDE A DAMP
BIT NOT SATURATED SEED BED.
b. THE ADDITION OF SOIL AMENDMENTS, PH ADJUSTMENT, LEACHING
COVERING SALINE SOILS TO PROVIDED VIABLE CONDITIONS FOR
GROWTH.
E HYDROSEEDING AREAS SHALL BE MAINTAINED TO PROVIDE A VIGOROUS GROWTH
UNTIL THE PROJECT IS PERMANENTLY LANDSCAPED OR, FOR AREAS WHERE
HYDROSEEDING IS THE PERMANENT LANDSCAPING, UNTIL THE PROJECT IS
COMPLETED AND ALL BONDS RELEASED.
STABILIZATION OR ESTABLISHED VEGETATION STABILIZATION BMPs ARE NOT CONSIDERED
TO BE "EXPOSED" FOR PURPOSES OF THIS REQUIREMENT.
THE SITE WITHIN 48 HOURS OF A PREDICTED STORM EVENT (A PREDICTED STORM EVENT
IS DEFINED AS A 40% CHANCE OF RAIN WITHIN A 5-DAY NATIONAL WEATHER SERVICE
FORECAST). ON REQUEST, THE OWNER/DEVELOPER/CONTRACTOR MUST PROVIDE PROOF
OF THIS CAPABILITY.
HAVE BEEN COMPLETED.
LIMITED TO THE AMOUNT OF ACREAGE THAT THE CONTRACTOR CAN ADEQUATELY PROTECT
PRIOR TO A PREDICTED RAIN EVENT. FOR LARGER SITES, GRADING SHOULD BE PHASED.
IT MAY BE NECESSARY TO DEPLOY EROSION AND SEDIMENT CONTROL BMPs IN AREAS THAT
ARE NOT COMPLETED, BUT ARE NOT ACTIVELY BEING WORKED BEFORE ADDITIONAL GRADING
IS ALLOWED TO PROCEED, AT THE DISCRETION OF THE CITY INSPECTOR.
IN ADDITION, TREATMENT CONTROL BMPs MUST BE SERVICED AS NEEDED THROUGHOUT
2.DEVICES SHOWN ON CITY APPROVED PLANS SHALL NOT BE MOVED OR MODIFIED
3. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER
4. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE
REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORSEEN
THROUGHOUT THE DURATION OF THE CONSTRUCTION WORK (YEAR ROUND).
WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR.
TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL.
CIRCUMSTANCES WHICH MAY ARISE.
5. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS
TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS
CONDITION.
6.GRADING AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE
OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY.
7. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING
DAY WHEN FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT
AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL.
8. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE.
INSTALLED. THIS INCLUDES ALL BUILDING PADS, UNFINISHED ROADS, AND SLOPES.
WILL BE UPGRADED, IF NECESSARY, TO PROVIDE SUFFICIENT PROTECTION FROM RUNOFF
DURING RAIN EVENTS.
TO INSTALL BMP MATERIALS IN A PROMPT MANNER IS NOT SUFFICIENT. BMPs NEED TO BE
INSTALLED IN THESE AREAS.
WITHIN A THREE (3) DAY FORECAST, THE INSPECTOR WILL VERIFY THAT BMPs ARE
ADEQUATELY STOCKPILED. BMPs MUST BE STOCKPILED AND READY FOR DEPLOYMENT WHEN
THERE IS 50% CHANCE OF RAIN WITHIN A 48 HOUR FORECAST. FAILURE TO COMPLY WITH
THIS REQUIREMENT COULD RESULT IN THE ISSUANCE OF A STOP WORK NOTICE OR OTHER
ENFORCEMENT ACTION.
THE YEAR.
1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT: KEVIN DUNN AT
(TEL.NO.) (949) 637-3254
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
TIER 2 SWPPP
Best Management Practice*
(BMP) Description
Construction Activity
CASQA Designation
BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE
Pollution Control BMPs
Waste Management and Materials
Management BMPs
Non-Storm Water
Control BMPs
Tracking
BMPs Sediment Control BMPsErosion Control
TELEPHONE NO.: (949) 637-3254
TELEPHONE NO.: (949) 637-3254
ADDRESS: - 5315 AVENIDA ENCINAS, SUITE 220 CARLSBAD, CA 92008
NAME: KEVIN DUNN FOR: RINCON ESTATE GROUP
CONSTRUCTION WORK IS COMPLETE AND SIGNED OFF BY THE CITY OF CARLSBAD.
THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE
AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 2 CONSTRUCTION SWPPP
I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT
BEST MANAGEMENT PRACTICES (BMPs) DURING CONSTRUCTION ACTIVITIES
TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID THE MOBILIZATION OF
POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM
WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND
19,247
CARLSBAD, CA 92008
330 CHINQUAPIN AVENUE
206-020-11-00
TRENCHES, BACKFILL CUTS AND SLOPE KEYWAYS)
WORKER FOOT TRAFFIC, SOIL/GRAVEL PILES, UTILITY
AND EQUIPMENT STAGING AREAS, CONSTRUCTION
AND TEMPORARY DISTURBANCE SUCH AS VEHICLE
OFF-SITE WORK INCLUDING PUBLIC IMPROVEMENTS
(THIS AREA INCLUDES BUT IS NOT LIMITED TO
MEDIUMHIGH
CONSTRUCTION THREAT TO STORM WATER QUALITY (CHECK BOX):
ADDRESS: 5315 AVENIDA ENCINAS, SUITE 200 CARLSBAD, CA 92008
NAME: 330 CHINQUAPIN LLC
SHEET 7: TIER 2 SWPPP EROSION CONTROL PLAN
SHEET 6: TIER 2 SWPPP TITLE SHEET
S.F.AREA OF DISTURBANCE
KEVIN DUNN FOR: 330 CHINQUAPIN LLC
DATEOWNER(S)/ OWNER'S AGENT NAME (SIGNATURE)
DATEOWNER(S)/ OWNER'S AGENT NAME (PRINT)
3/22/2023
AM 538-7A
TIER 2 CITY STORM WATER
STORM WATER POLLUTION PREVENTION NOTES
GENERAL SITE MANAGEMENT REQUIREMENTS EROSION CONTROL HYDROSEEDING, PLANTING AND IRRIGATION
WEATHER TRIGGERED ACTION PLAN
POLLUTION PREVENTION PLAN (TIER 2 SWPPP)
SHEET INDEX: OWNER/APPLICANT:
APN ·
EMERGENCY CONTACT:
\ \,.. SITE ADDRESS:
OWNER'S CERTIFICATION:
AREA OF DISTURBANCE
'
VICINITY MAP CONSTRUCTION THREAT:
181 □
C:
➔
C: C: .2 --""
.2 .2 -iii "" iii --0, 0
C: "' § <.> <.> C: :s ·E E C: E .2 -2 .s .2 .9-0 0 E -"' -::;; "" "' 0,
-~
~ --.s ;5. ::, c 0, ~ ~ 0 .8 §~ .s "' "' "' .z-0 0, g.. "' .s § "' J G ~ "' 0, ~ .s a:, g. a; " § C: 0, "' ., "' ~ 0 .s u~ -·.; "' .s
~
.s "' "" "' ::;; -2 ~ "" "' " VJ "' E i 0, "' 0, a:, 0 C: C: "" "' ~ C: c:, ::, -" "' ~CJJ ~ <.> -0 0 ~-£ ... 0 ]~ "" 0 "' C: C: 0 "' ~ "" c:, a:, 0, "s 0.2 0, " -::;; c:, 0, C: C: _E Cl:.:; c., "' ~ 0, 0 " -~ "" :n .S;; "' " :S -~ ~ "' 0 E al ·" "' ~~ <.> 0,-~-£ ·-0, .l2-0 "' ~ ti 1 "' ::, .g ~~ i._:.:;
.s::: e ..Q ~ e "" " '-·-"" .$2 6 "' -"R -g.. " " ::, ... --g ... -g 0 " 0 0 0 CJJ .!Q 0 0 '-0 -., 0 '-<.>
~
0 0 ~o ~i -.c: " ~o -0 ct~ " ~ ~e's Vi 55 <Jl 6 ~ G ti~ Cf) ct -0, -o ~ ct 0 ~ ts ~en ~ -::t: <.o VJ .s VJ a:: CLO CL VJ
➔ "' .... " "' 0, -.,., " 0 "' -.,., " co -"' .,., --.... "' <o co --I I I I I I I I I I I I I I I I J, J, J, I I I I
G:l G:l
c.,
G:l G:l G:l bj bj bj bj bj bj bj bj ~ ~ ~ i i i kl '2: '2: '2:
vi Gradina/Soil Disturbance ✓ ✓ ✓ ✓
.,, Trenchina/txcavation ✓
Stockpilinq
Drillinn IBorina
J Concrete/Asphalt Sawcuttinq ✓ ✓
.,, Concrete Flatwork ✓ ✓ ✓ ✓
vi Paving ✓ ✓ ✓
.,, Conduit/Pipe Installation ✓
Stucco/Mortar Work
.,, Waste Disposal ✓ ✓ ✓
.I Staainn ILav Down Area ,/
[auioment Maintenance and Fuelina
,1 Hazardous Substance Use/Storaae ,,/
Dewaterina
Site Access Across Dirt
Other (list):
Instructions:
1. Check the box to the left of all applicable construction activity (first column) expected to occur during construction.
2. Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number.
or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column.
Choose one
J. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project.
"" C: 0 "' -C: "' .2 i---C: " C: C:
~ -"' "' "' i~ " E " ... -.g "' CL e 0, ... 0,
"" 0 oO ~c: :.::: § N C: bt8 c5l ::;; ~~
.... "' <o
I I I i i i
,/
✓ ✓
✓ ✓ ✓ ✓ ✓ ,/
✓ ✓ ,/
"' -"' i
.\! -" g. -"' VJ-o-
'"' iii '-.. iii
" E ~ ~ -" 1:' 0, 0 0,
<.> 0 :!;:O
C: C: C: § 8~ c5l ::;;
co 0,
I I i i
✓ ,/
✓
✓ ✓
,/
~II CITY OF CARLSBADILJ
PASCO LAREY SUITER
& ASSOCIATES
San Diego I Solana Beach I Orange County
Phone 858.259.8212 I www.plsaengineering.com
GRADING PLANS FOR:
APPROVED:
ENGINEERING MANAGER
DWN BY: ---1 CHKD BY: __
RVWD BY: .
JASON S. GELDERT
RCE 63912 EXPIRES 9/30/24 DAlE
PROJECT NO. I DRAWING NO.
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
SSS
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G
W W W
SD
SD
SD
SD
SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD
G G G G
S
S
S
S
S
S
S
S
S
S
S
W
SSS
X
XXXXXX
X
X
XXXXX
X
X
X X X
EXISTING 2 STORYEXISTING 1 STORY
EXISTING 1 STORY
BUILDING
EXISTING 1 STORY
BUILDING
SHED
3' WOOD FENCE
8' WROUGHT IRON
FENCE
6' WOOD FENCE6' WOOD FENCE6' WOOD FENCE
6' WOOD FENCE 6' WOOD FENCE
6' WOOD FENCE
3' WOOD FENCE
6' WOOD FENCE
X
X X X X
53
53
52
52
52
52
52
51
51
51
5
1
51
50
50
50
50
49
49
49
49 49
49
48
48 48
48
48 48
48
4
8
47
47
47
47 47 47
47
46
46
46 46
46
45
4545
45 44
43
FL=48.27
FL=47.40
FL=46.20
FL=46.14
FL=45.30
FL=44.59
FL=44.45
FL=43.98
TC=48.74
TC=47.85
TC=46.26
TC=46.68
TC=45.38
TC=44.74
TC=44.90
TC=44.14
OE
OE
OE
OE
OE
OE
OE
OE
OE
COMM POST
SI
D
E
W
A
L
K
DR
I
V
E
W
A
Y
EN
T
R
A
N
C
E
WA
L
K
W
A
Y
WALKWAY
WALKWAYWA
L
K
W
A
Y
PATIO
PATIO
BLDG OVERHANG
BLDG OVERHANG
45.9
46.747.247.748.2
48.5
48.5
48.8
48.8
48.7
49.4 49.4
49.4
49.4
49.5
49.1 49.1
49.4
49.5
49.4
49.7
49.4
49.4
49.4
49.3
49.3
49.4
49.4
49.2
48.9
49.0
51.4
51.3
51.5
51.4
51.3 51.2
51.2
51.8
51.6
51.2
50.8
50.4
49.7
49.4
48.7
48.3 48.6
48.3
52.3
52.5
52.3
52.6 52.2
52.2
51.5
51.3
51.7
51.4
51.7
51.3
51.8
51.4
51.6
51.5
50.5
50.7
50.3
50.6
50.3
50.7
50.3
50.8
50.4
50.6
50.2
49.7
49.2
49.8
49.3
49.6
49.4
49.8
49.3
49.7
49.2
49.7
48.7
48.7
48.7
48.7
48.6 48.5
51.8
47.2
47.6
49.4
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXX
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
XXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
XXXX
X
X X
XX
X X
X X
X
N 34°00'09" W 274.76'
N 34°00'09" W 274.78'
N
5
5
°
5
9
'
0
3
"
E
7
0
.
0
0
'
25.0'25.0'
CH
I
N
Q
U
A
P
I
N
A
V
E
50.0'
N
5
5
°
5
8
'
2
7
"
E
7
0
.
0
0
'
UNIT 1
FF= 48.9
PAD= 48.2
UNIT 2
FF= 48.9
PAD= 48.2
UNIT 3
FF= 48.9
PAD= 48.2
UNIT 4
FF= 49.7
PAD= 49.0
UNIT 5
FF= 49.7
PAD= 49.0
UNIT 6
FF= 49.7
PAD= 49.0
UNIT 7
FF= 50.7
PAD= 50.0
UNIT 8
FF= 50.7
PAD= 50.0
UNIT 9
FF= 50.7
PAD= 50.0
SD-G SD-G
SD-B
SD-B SD-B
SD-B
SD-B
SD-B
SD-B
SD-B SD-B
SD-BSD-B
SD-B
SD
-
K
SD
-
K
SD-F
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
BAK
PA
S
C
O
,
L
A
R
E
T
,
S
U
I
T
E
R
&
A
S
S
O
C
I
A
T
E
S
19
1
1
S
A
N
D
I
E
G
O
A
V
E
N
U
E
,
S
A
N
D
I
E
G
O
,
C
A
9
2
1
1
0
PH
:
(
8
5
8
)
2
5
9
-
8
2
1
2
F
A
X
:
(
8
5
8
)
2
5
9
-
4
8
1
2
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
PUD 2021-0010
CT 2021-0005
13
538-7A
GR 2022-0029
6
GRAPHIC SCALE: 1" = 10'
0 10 20 30
PLAN VIEW - EROSION CONTROL PLAN
SCALE: 1" = 10' HORIZONTAL
PLSA 3729J:\ACTIVE JOBS\3729 RINCON 330 CHINQUAPIN\CIVIL\DRAWING\GRADING PLANS\3729-CV-GP-06-SWPPP.DWG
EROSION CONTROL PLAN
DETAIL B: GRAVEL BAGS
NOT TO SCALE
DETAIL A: CONSTRUCTION ENTRANCE
NOT TO SCALE
DETAIL C: SILT FENCE
NOT TO SCALE
PROVIDE APPROPRIATE TRANSITION
BETWEEN STABILIZED CONSTRUCTION
ENTRANCE AND PUBLIC RIGHT-OF- WAY
*LESSER DISTANCE ALLOWED WITH CITY INSPECTOR APPROVAL
50'MIN.*
PLAN
DRIVE AISLE
EXISTING GROUND
3" TO 6" COARSE AGGREGATE
50'MIN.*
12" MIN.
PROFILE
16'MIN.
GRADE
6% TO 8%
4% TO 6%
2% TO 4%
25'
40'
50'
100'LESS THAN 2%
INTERVAL
GRAVEL BAG ROW SPACING TABLE
AREA DRAIN
TWO LAYERS OF GRAVEL
BAGS WITH ENDS
OVERLAPPED
ACTS AS SPILLWAY
GAP BETWEEN BAGS
RUNOFF
WIRE
FILTER FABRIC
4 IN (10 CM)
EXCAVATED SOIL.
4. BACKFILL AND COMPACT THE
INTO THE TRENCH.
THE WIRE FENCE AND EXTEND IT
3. ATTACH THE FILTER FABRIC TO
THE POSTS.
2.STAPLE WIRE FENCING TO
ALONG THE LINE OF POSTS.
TRENCH UPSLOPE FROM AND
4 BY 4 IN (10 BY 10 CM)
1. SET POSTS AND EXCAVATE A
LOW IMPACT DEVELOPMENT COMPONENTS
SD-G CONSERVE NATURAL FEATURES
SD-B DIRECT RUNOFF TO PERVIOUS AREAS
SD-K SUBSTAINABLE LANDSCAPING
SD-F SIGNAGE TO DISCOURAGE DUMPING
SE-1, SILT FENCE
SE-6, GRAVEL BAG
TR-1, STABILIZED
CONSTRUCTION ENTRANCE
STREET SWEEPING AND
VACUUMING PER SE-7
SCHEDULING PER EC-1
MATERIAL DELIVERY AND
STORAGE PER WM-1
MATERIAL USE MANAGEMENT
PER WM-2
STOCKPILE MANAGEMENT
PER WM-3
SPILL PREVENTION AND
CONTROL PER WM-4
SOLID WASTE MANAGEMENT
PER WM-5
HAZARDOUS WASTE
MANAGEMENT PER WM-6
CONCRETE WASTE
MANAGEMENT PER WM-8
SANITARY / SEPTIC WASTE
MANAGEMENT PER WM-9
PAVING AND GRINDING
OPERATIONS PER NS-3
VEHICLE AND EQUIPMENT
CLEANING PER NS-8
QUANTITYLEGEND
225 EA
690 LF
1,000 SF
AM
' ' '
-----
-a' •
,
t '----------~-~-----------------~--------------------~------------------
• ••
• > • □-~~~=r---------D
,x
D --
D X
X -
-------------------
H--'-c~rt-11 · l .
& . ~ . ,_,_,------~.., I
• X
.-------------------
---/ --.. I \I
X
D
----' ' ,_ -
X
X
---------X
X
X
ii. -, --------------' ._ -'=""-, ' I . ' ---
_J X X
a 11 ~
,
,
D
D
D
D
--
------------
---------------
D X
----
X
X
X
• ,
•
------
_ _J
X
X
X
-----·-•
□ □
-1ssv1
SCH
-
I MUM I e) T
@
~
Lt.
C\\M
B
PG
VEC
• •
----
• --
•
I
I I .
X
•
• • ::;;F. ,; ra"i .
X • ,I c.. I
rt. r
I
I I
D
,
D
r
I ,.
• ,
L /-·
• ~ . ~ ---~((,~-
! >•,, I
.'. 1
.~ ~ .
,_ ,;\
. \,.
•
SSV
-----------
PASCO LAREY SUITER
& ASSOCIATES
San Diego I Solana Beach I Orange County
Phone 858.259.8212 I www.plsaengineering.com
1-----1--+-------------t---;---;---r-~~II CITY OF CARLSBADILJ
GRADING PLANS FOR:
APPROVED: JASON S. GELDERT
ENGINEERING MANAGER RCE 63912 EXPIRES 9 30 24 DAlE
DA 1E INITIAL
ENGINEER OF WORK
DA 1E INITIAL DAlE INITIAL
REVISION DESCRIPTION DlHER APPROVAL CITY APf'ftOVAL
DWN BY: __ _
CHKD BY: __ _
RVWD BY:
PROJECT NO. I DRAWING NO.
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G
W W W
SD
SD
SD
SD
SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD
G G G G
S
S
W
SSS
X
XXXXXX
X
X
XXXXX
X
X
X X X
EXISTING 2 STORYEXISTING 1 STORY
EXISTING 1 STORY
BUILDING
EXISTING 1 STORY
BUILDING
SHED
3' WOOD FENCE
8' WROUGHT IRON
FENCE
6' WOOD FENCE6' WOOD FENCE6' WOOD FENCE
6' WOOD FENCE 6' WOOD FENCE
6' WOOD FENCE
3' WOOD FENCE
6' WOOD FENCE
X
X X X X
53
53
52
52
52
52
52
51
51
51
5
1
51
50
50
50
50
49
49
49
49 49
49
48
48 48
48
48 48
48
4
8
47
47
47
47 47 47
47
46
46
46 46
46
45
4545
45 44
43
FL=48.27
FL=47.40
FL=46.20
FL=46.14
FL=45.30
FL=44.59
FL=44.45
FL=43.98
TC=48.74
TC=47.85
TC=46.26
TC=46.68
TC=45.38
TC=44.74
TC=44.90
TC=44.14
OE
OE
OE
OE
OE
OE
OE
OE
OE
COMM POST
SI
D
E
W
A
L
K
DR
I
V
E
W
A
Y
EN
T
R
A
N
C
E
WA
L
K
W
A
Y
WALKWAY
WALKWAYWA
L
K
W
A
Y
PATIO
PATIO
BLDG OVERHANG
BLDG OVERHANG
45.9
46.747.247.748.2
48.5
48.5
48.8
48.8
48.7
49.4 49.4
49.4
49.4
49.5
49.1 49.1
49.4
49.5
49.4
49.7
49.4
49.4
49.4
49.3
49.3
49.4
49.4
49.2
48.9
49.0
51.4
51.3
51.5
51.4
51.3 51.2
51.2
51.8
51.6
51.2
50.8
50.4
49.7
49.4
48.7
48.3 48.6
48.3
52.3
52.5
52.3
52.6 52.2
52.2
51.5
51.3
51.7
51.4
51.7
51.3
51.8
51.4
51.6
51.5
50.5
50.7
50.3
50.6
50.3
50.7
50.3
50.8
50.4
50.6
50.2
49.7
49.2
49.8
49.3
49.6
49.4
49.8
49.3
49.7
49.2
49.7
48.7
48.7
48.7
48.7
48.6 48.5
51.8
47.2
47.6
49.4
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXX
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
XXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
XXXX
X
X X
XX
X X
X X
X
CH
I
N
Q
U
A
P
I
N
A
V
E
1
2
3
4
5
6
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
BAK
PA
S
C
O
,
L
A
R
E
T
,
S
U
I
T
E
R
&
A
S
S
O
C
I
A
T
E
S
19
1
1
S
A
N
D
I
E
G
O
A
V
E
N
U
E
,
S
A
N
D
I
E
G
O
,
C
A
9
2
1
1
0
PH
:
(
8
5
8
)
2
5
9
-
8
2
1
2
F
A
X
:
(
8
5
8
)
2
5
9
-
4
8
1
2
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
PUD 2021-0010
CT 2021-0005
13
538-7A
GR 2022-0029
7
GRAPHIC SCALE: 1" = 10'
0 10 20 30
PLAN VIEW - TRASH CAPTURE
SCALE: 1" = 10' HORIZONTAL
PLSA 3729J:\ACTIVE JOBS\3729 RINCON 330 CHINQUAPIN\CIVIL\DRAWING\GRADING PLANS\3729-CV-GP-07-BMP.DWG
BMP PLAN
1 1 EA DWG 538-7A
SHEETS 3
(949)-637-3254
LOW IMPACT DESIGN (L.I.D.)
ANNUALLY &
AS-NEEDEDTC-50 SEMI-ANNUALLY
TRASH CAPTURE BMPs
QUANTITY FREQUENCY
INSPECTION
BMP TABLE
FREQUENCY
MAINTENANCESHEET NO.(S)DRAWING NO.CASQA NO.SYMBOLBMP ID #BMP TYPE
KEVIN DUNN5315 AVENIDA ENCINAS,
SUITE 200
CARLSBAD, CA 92008
330 CHINQUAPIN LLC
PROPERTY BOUNDARY
CENTERLINE OF ROAD
ADJACENT PROPERTY LINE
PUBLIC RIGHT-OF-WAY
LEGEND
(858) 259-8212
SAN DIEGO, CA 92110
1911 SAN DIEGO AVENUNE
PLSA ENGINEERING
BRYAN KNAPP
THE EOW WILL VERIFY THAT PERMANENT BMPS ARE CONSTRUCTED AND
OPERATING IN COMPLIANCE WITH THE APPLICABLE REQUIREMENTS. PRIOR
TO OCCUPANCY THE EOW MUST PROVIDE:
1. PHOTOGRAPHS OF THE INSTALLATION OF PERMANENT BMPS PRIOR
TO CONSTRUCTION, DURING CONSTRUCTION, AND AT FINAL
INSTALLATION.
2.A WET STAMPED LETTER VERIFYING THAT PERMANENT BMPS ARE
CONSTRUCTED AND OPERATING PER THE REQUIREMENTS OF THE
APPROVED PLANS.
3. PHOTOGRAPHS TO VERIFY THAT PERMANENT WATER QUALITY
TREATMENT SIGNAGE HAS BEEN INSTALLED. PRIOR TO RELEASE OF
SECURITIES, THE DEVELOPER IS RESPONSIBLE FOR ENSURING THE
PERMANENT BMPS HAVE NOT BEEN REMOVED OR MODIFIED BY THE
NEW HOMEOWNER OR HOA WITHOUT THE APPROVAL OF THE CITY
ENGINEER.
BMP CONSTRUCTION AND INSPECTION NOTES:
SIGNATURE
6. SEE PROJECT SWQMP FOR ADDITIONAL
INFORMATION.
5. REFER TO MAINTENANCE AGREEMENT DOCUMENT.
COMPANY
CERTIFICATION
PHONE NO.
ADDRESS
NAME
PLAN PREPARED BY:
CONTACT
PHONE NO.
ADDRESS
NAME
PARTY RESPONSIBLE FOR MAINTENANCE:
BMP NOTES:
AND INSTALLATION.
HAS INSPECTED THIS PROJECT FOR APPROPRIATE BMP CONSTRUCTION
4. NO OCCUPANCY WILL BE GRANTED UNTIL THE CITY INSPECTION STAFF
WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER.
3. NO SUBSTITUTIONS TO THE MATERIAL OR TYPES OR PLANTING TYPES
APPROVAL FROM THE CITY ENGINEER.
2. NO CHANGES TO THE PROPOSED BMPS ON THIS SHEET WITHOUT PRIOR
RECOMMENDATIONS AND/OR THESE PLANS.
1. THESE BMPS ARE MANDATORY TO BE INSTALLED PER MANUFACTURER'S
TO IMPERVIOUSDIRECT RUNOFF
AREA25- AS-NEEDEDANNUALLY1 EASD-11 DWG 538-7A
SHEETS 3
REM TRITON
TDAM 5(12) PEFF -
FTC (5" X 12")
86542
1 EA DWG 538-7A
SHEETS 3
ANNUALLY &
AS-NEEDEDTC-50 SEMI-ANNUALLYREM TRITONTDAM 8(10) PEFF -
FTC (8" X 10")
6
AM
I \ .. ----------
,..__ -----
/ ---........:::: -------
---'
------------
X
---..
' ----
__J -'=--
l--~~~~~~~~~~~:~:~:::--=--==-~=--~=-=:-=-_--------------===~/-----------1\/-------------X +~----------------------------------------------------------------r ------------
X
X
-----------------
X
--------
--------
----
----
X
II--II
--------------- --~----
•
X
----------
X
-------
X
II
,
X
X
X
X
-------------
X
----, I
' X I \ I
\ ----1----I ------t-_-.J-:-----=-'--"f=":
X
X
X X
X .,,., ---/ ----....... ____ I --
. X --1a====L_ _ __J__ . --.., J ~~----l~==~L-
-----
/ X /
-, ,
• • •
II
• , ... --
".
•
I r
----------
0 .... .... .... ....
----....................
0 ----------...................
00 •
--
--
X
X
.,--. . j , -~7 ~~ ~ ~~ -• ..
' " --~_ .... \: ~□-i'rnl~~ /
:_,c.31J,1 \ \I f ly_ -.~ t I \ -
------
,· .· \ \, '. ·.· ..
,.-.::1 . ~ I · .. -_· -·._:...-:
. ~ I\-'-' -~ .. I ~--p l ' ' . . . . . .
::;;r; t' . . ·._ •i:,I I \ . . . . . . . . . . . .
; ~ ~-.. ~1,-~ 1::-·-c-'-,-,.£,....C,,.-•-•~•-· ·~•-~jlf ~ ~--~ ~~ ~ . . . ·~. ~ \ \ 1·:7··. . · :
( ~~-. • 't;-µ.-,=t:===::· .,..~==='!'::!'---;t.--.-j • __.;,-.;_ ' •• \ •~' . . .. . .. . .
,
I
•
:1 t>~ ~,.J \\·
< ~ i . f-YF>-l-"'---"".L.11 '; 1 · 1 \},\ \1-·;.c...~;...;.-..:-..i
l';--=-;'I. I x I L';x=-;--rj_ I, • • • . 7.\
! •11• ', • 1 I \ \\ .
• l
I . •
• X \• .\ ,, / \ .
1· f \ \
L 1 ·\~·-_ ._ • 11>-\''~ro /---• ~-1, \ n..-'-<-""1\
·1 . Y ~ r , \ \'·I-'-'->-.L:~-'!.
11111-11 l( • L~ • .:I' \ \: I\.L--"~----r++.+.
► ~ ➔ \ \ 117,~_,,,_,,,...,_,,, ==::;::: ,_!J---'-'1 .• ,
----. ----, -~--,v . ~. -·
I
I
I
I
1
\ • I •. \ I \1-.--!r"<"~~I\
·H-c-'--l1~il \ ' '' }.,t. \ \
=--·~□i•U•~•t·'.::='.:::'.:::c:::'.::='.:::'.:::'.J=''.::='.:::'.::-:="_:=:'.':::':=~~
i .
•
-----------
PASCO LAREY SUITER
& ASSOCIATES
San Diego I Solana Beach I Orange County
Phone 858.259.8212 I www.plsaengineering.com
t------+---+-----------+-----+---+-----+---t ~ 11 CITY OF CARLSBAD I LJ
GRADING PLANS FOR:
APPROVED: JASON S. GELDERT
ENGINEERING MANAGER RCE 63912 EXPIRES 9 30 24 DAlE
DA 1E INITIAL
ENGINEER OF WORK REVISION DESCRIPTION
DA 1E INITIAL DAlE INITIAL
DlHER APPROVAL CITY APf'ftOVAL
DWN BY:
CHKD BY: __ _
RVWD BY:
PRO.ECT NO. DRAWING NO.
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
ROY P. REED R.C.E. 80503 EXP. 3-31-2025 DATE
4/3/2023 R IOFT
A
A NILFOEAT
S
C
N
G
N
LANOFOP
I
I
R
R SS
EE
E
E
DERETSIGER
D
EREP.OR
Exp.
C 80503
3/31/25
LIVIC
Y
7727 CAMINITO LILIANA
SAN DIEGO, CA 92129, (760)586-8121
E G
G
S
C
W
X
XXXXXX
X
X
XX
X
X
X
X
X
X
X
X
X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXX
X
X
X X X
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 2 STORY
BUILDING
EXISTING 1 STORY
BUILDING
SHED
3' WOOD FENCE
8' WROUGHT IRON
FENCE
6' WOOD FENCE6' WOOD FENCE6' WOOD FENCE
6' WOOD FENCE 6' WOOD FENCE
6' WOOD FENCE
3' WOOD FENCE
6' WOOD FENCE
X
X
X X X X
53
53
52
52
52
52
52
51
51
51
5
1
51
50
50
50
50
50
49
49
49
49 49
49
48
48 48
48
48 48
48
4
8
47
47
47
47 47 47
47
46
46
46 46
46
45
4545
45
44
44
44
44
43
42
FL=48.27
FL=47.40
FL=46.20
FL=46.14
FL=45.30
FL=44.59
FL=44.45
FL=43.98
FL=43.34
FL=42.92
FL=42.66
FL=40.82
TC=48.74
TC=47.85
TC=46.26
TC=46.68
TC=45.38
TC=44.74
TC=44.90
TC=44.14
TC=43.48
TC=43.08
TC=43.11
TC=41.25
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
COMM POST
SI
D
E
W
A
L
K
DR
I
V
E
W
A
Y
EN
T
R
A
N
C
E
DR
I
V
E
W
A
Y
EN
T
R
A
N
C
E
WALKWAY
PATIO
42.7 42.3 42.7
42.8 42.7 43.4
45.9
46.747.247.748.2
48.5
48.5
48.8
48.8
48.7
49.4 49.4
49.4
49.4
49.5
49.1 49.1
49.4
49.5
49.4
49.7
49.4
49.4
49.4
49.3
49.3
49.4
49.4
49.2
48.9
49.0
51.4
51.3
51.5
51.4
51.3 51.2
51.2
51.8
51.6
51.2
50.8
50.4
49.7
49.4
48.7
48.3 48.6
48.3
52.3
52.5
52.3
52.6 52.2
52.2
51.5
51.3
51.7
51.4
51.7
51.3
51.8
51.4
51.6
51.5
50.5
50.7
50.3
50.6
50.3
50.7
50.3
50.8
50.4
50.6
50.2
49.7
49.2
49.8
49.3
49.6
49.4
49.8
49.3
49.7
49.2
49.7
48.7
48.7
48.7
48.7
48.6 48.5
51.8
47.2
47.6
49.4
OE
OE
OE
OE
42
43
44
45
46
47
48
X
X
X
X
X X
X
X
X
X
X
X X
X
X
X
X
X
X X X X
X
X
X
X
X
X X
X
X
X
X
X
X
X
XXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
W W W W
WM
WM W W W
W W W
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
S S S S S S S S S
W W W
SD
SD
SD
SD
SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD
SD
SD
G G G G
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
(49.0)
FG
(48.8)
FG
(48.5)
FG (48.2)
FG
48.2 TW@EG
47.5 TW@FS
(46.3 BW@FG)
(48.7 TW@EG)
47.3 TW@FG
(45.8 BW@EG)
(48.4 TW@EG)
47.0 TW@FS
(45.6 BW@EG)
(53.4)
FG
(53.8)
FG
(54.0)
FG
(54.2)
FG
(54.3)
FG
(54.3)
FG
(54.3)
FG
(54.1) FG(54.3)
FG
GFF = 50.0 GFF = 50.0
GFF = 49.0 GFF = 49.0 GFF = 49.0 GFF = 48.2 GFF = 48.2 GFF = 48.2
UNIT 1
FF= 48.7
PAD= 48.2
UNIT 2
FF= 48.7
PAD= 48.2
UNIT 3
FF= 48.7
PAD= 48.2
UNIT 4
FF= 49.5
PAD= 49.0
UNIT 5
FF= 49.5
PAD= 49.0
UNIT 6
FF= 49.5
PAD= 49.0
UNIT 7
FF= 50.5
PAD= 50.0
UNIT 8
FF= 50.5
PAD= 50.0
UNIT 9
FF= 50.5
PAD= 50.0
49.52 FS 49.29 FS 48.5 FS 48.51 TC
48.01 FL
46.4 TC
46.4 FL
45.97 TC
45.47 FL
49.40 FL
49.17 FL 48.32 FL
49.46 FS
49.40
FS
49.31 FS
49.22 FS49.42 FL
49.55 FL
49.60 FL
49.8 FG/HP
49.6 FL
50.0 FG
50.0 FG
49.5 FG 48.8 FL
49.92 FS
49.96 FS 49.90 FS
50.00
FS 50.00 FS
49.85 FS
49.82 FS
48.81 FS
49.72 FS
48.66 FS
49.68 FS
48.42 FS
49.63 FS
49.35 FS 49.11 FS
48.84 FS
48.09 FS
48.78 FS
48.15 TC
47.65 FL
47.85 FS
48.80 FS
47.95 TC
47.45 FL
48.74 FS
48.72 FS
47.40 FS 47.3 FS
48.67 FS
48.42 FS
48.20 FS 47.94 FS
47.0 FS
46.8 FS
47.90 FS
47.89 FS 47.85 FS
46.75 FS 46.6 FS 46.5 FS 46.3 FS
47.82 FS
47.78 FS
47.55 TC
47.05 BC
3.
7
%
3.
7
%
0.
5
%
0.
6
%
4.
1
%
4.
6
%
4.
6
%
7.
9
%
7.
9
%
7.
0
%
7.
0
%
9.
3
%
9.
3
%
4.
0
%
4.
0
%
5.
1
%
5.
1
%
5.
4
%
5.
4
%
6.
5
%
6.
5
%
7.
1
%
7.
1
%
8.
2
%
8.
2
%
6.
4
%
6.
4
%
7.
5
%
7.
5
%
7.
8
%
7.
7
%
8.
8
%
8.
8
%
9.
5
%
9.
5
%
10
.
6
%
10
.
6
%
8.
6
%
1.0%
0.4%
0.4%
0.4%
0.4%
3.0%
0.3%
0.3%
0.3%
0.3%
0.3%
2.8%
0.3%
0.3%0.3%
0.3%4.6%
0.3%
1.5%
1.5%1.0%
6.0%
1.0%1.0%1.5%1.0%1.
5
%
1.
5
%
1.
5
%
5.0%1.
3
%
1.
6
%
1.
0
%
1.
0
%
0.9
%
1.0%
1.0
%
0.
9
%
1.
0
%
1.0%1.0%1.0%1.0%1.0%1.0%
49.0 FG
49.0 FG
48.2 FG 48.2 FG
47.7 FG
46.9 TG
45.6 IE
48.50 FS
48.50 FS49.50 FS 49.50 FS
0.
7
%
1.4%
2.
0
%
0.
4
%
1.1%
1.
6
%
52.4 TW
(52.0 TW@FG)
50.0 BW
49.1 TF
BEGIN C-2 WALL;
53.7 TW
50.0 BW@FG
49.1 TF
53.0 TW
49.0 BW@FG 53.0 TW
52.0 TW@FG
52.00 TW
51.4 TW@FG
48.2 BW
50.0 TW
49.4 TW@FG
47.7 BW
END C-2 WALL
49.1 TW
48.7 TW@FG
47.4 BW
46.3 TF
BEGIN C-2 WALL
47.8 TW
47.8 BW
GR
A
D
E
B
R
E
A
K
10.0'
FYSB
10.0' RYSB
5.
0
'
SY
S
B
5.
0
'
SY
S
B
20
.
0
'
4.
0
'
24
.
0
'
20
.
0
'
8.5'
8.0'8.0'
24
.
0
'
15
.
0
'
24
.
0
'
15
.
0
'
20
.
0
'
4.
0
'
20
.
0
'
4.
0
'
8.0'17.0'
25.0'
5.0'
49
48
47
46
48.62 FS
5.0'
EX
.
6
"
V
C
S
W
R
@
4
.
4
%
EX
.
6
"
A
C
W
T
R
(
D
W
G
1
4
6
-
6
)
EX
.
1
"
H
P
G
A
S
25.0' TO PL
47.1
FS
48.2 FS
48.15 FS
GFF = 50.0
48.4 TW
48.3 TW@FG
47.8 BW
46.3 TF
EX WALL
TO REMAIN
EX WALL
TO REMAIN
END C-2 WALL
50.0 TW
49.6 BW
49.1 TF
(53.5 TW)
(49.5 TW @ FG)
(47.1 BW @ FG)
(47.1 FS)
EX WALL
TO REMAIN
(50.7 TW)
(50.0 TW @ FG)
(47.7 BW @ FG)
(52.8 TW)
(52.1 TW @ FG)
(48.9 BW @ FG)
(49.8 FS)
(53.6 TW)
(52.9 TW @ FG)
(50.0 BW @ FG)
(54.0 TW)
(53.4 BW)4.
7
'
4.
9
'
10
.
0
'
12
.
6
'
EX PCC DWY
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING
ASPHALT
TO REMAIN
EXISTING EDGE
OF ASPHALT
EXISTING EDGE
OF ASPHALT
49.5 FG
49.0 FG
48.4 FG
48.2 FG
48.4 FG
344 CHINQUAPIN AVE
APN 206-020-27-00350 CHINQUAPIN AVE
APN 206-020-34-00
306 CHINQUAPIN AVE
APN 206-020-12-00
EX WALL
TO REMAIN
EX OVERHEAD
UTILITIES TO
REMAIN
EX OVERHEAD
UTILITIES TO
REMAIN
PROP SSCO
RIM=49.52
IE= 40.0
49.4 TG
48.5 IE
49.3 TG
48.4 IE
49.0 TG
48.1 IE 48.6 TG
47.9 IE
48.3 TG
47.7 IE
48.1 TG
47.5 IE
47.7 TG
47.1 IE
47.4 TG
46.8 IE
47.2 TG
46.2 IE
47.0 TG
45.3 IE
46.3 TG
44.9 IE IN WEST
44.6 IE OUT
SIGHT DISTANCE
L = 150 FT
(VM = 20 MPH)
CALTRANS CORNER
SIGHT DISTANCE; SEE
NOTE THIS SHEET
24
.
0
'
5.0'
16.5'
0.4%
MIN
50.0 FG
5.0
%
MI
N
52.4 TW
49.5 BW@FG
48.4 TF
3.
3
'
5.0
%
MIN
49.5 FG
49.3 FL
49.0 FG
5.0
%
MI
N
5.0
%
MI
N
5.0
%
MI
N
5.
0
%
MI
N
5.0
%
MI
N
5.0
%
MI
N
RET. WALL
FOOTING (TYP.)48.5 FG
48.5 FG
5.0
%
MI
N
52.0 TW
51.5 TW@FG
48.5 BW
5.0%
MIN
47.0 FG
50.00 TW
49.1 TW@FG
48.2 BW
EX. RET. WALL
TO BE REMOVED SIGHT DISTANCE
L = 150 FT
(VM = 20 MPH)
CH
I
N
Q
U
A
P
I
N
A
V
E
(S
E
E
D
W
G
5
3
8
-
7
F
O
R
P
U
B
L
I
C
I
M
P
R
O
V
E
M
E
N
T
S
I
N
R
O
W
)
48.0 TW@EG
48.0 TW@FS
(47.0 BW@FG)
GR
A
D
E
B
R
E
A
K
GR
A
D
E
B
R
E
A
K
PROPOSED
TRANSFORMER
50.00 TW
49.1 TW@FG
48.2 BW
5.
0
'
3.
3
'
53.0 TW
49.5 BW@FG
N 34°00'09" W 274.76'
N 34°00'09" W 274.78'
N
5
5
°
5
9
'
0
3
"
E
70
.
0
0
'
N
5
5
°
5
8
'
2
7
"
E
70
.
0
0
'
48.7 TC
48.2 FS 48.7 TC
48.2 FS48.7 TC
48.2 FS
48.7 TC
48.2 FS
48.7 TC
48.2 FS48.7 TC
48.2 FS
49.5 TC
49.0 FS
50.5 TC
50.0 FS
50.5 TC
50.0 FS 50.5 TC
50.0 FS
50.5 TC
50.0 FS
50.5 TC
50.0 FS 49.5 TC
49.0 FS
49.5 TC
49.0 FS49.5 TC
49.0 FS
49.5 TC
49.0 FS
49.5 TC
49.0 FS
49.86 TC
49.36 FS
49.94 TC
49.44 FS50.43 TC
49.93 FS
DEEPEN PCC C&G AS
NECESSARY BENEATH
EXISTING SLOPE
PROPOSED WALL AND FENCE
COMBINATION NOT TO EXCEED 6'
PROPOSED FENCE
NOT TO EXCEED 6'
50.3 FS
50.3 FS 50.3 FS
49.3 FS 49.3 FS 49.3 FS 48.7 FS 48.7 FS
DESIGN BUILD PLANS:
STATE OF CALIFORNIA
DEPARTMENT OF INDUSTRIAL RELATIONS
DIVISION OF OCCUPATIONAL SAFETY AND HEALTH
TRENCH/EXCAVATION PERMIT NO._ _ _ _ _ _ _ _ _ _ _ _
Know what's below.
before you dig.Call
R
DIG ALERT!! TWO WORKING DAYS BEFORE DIG
ALL EXISTING UTILITIES MAY NOT BE SHOWN ON THESE PLANS
DIG ALERT & GENERAL CONTRACTOR SHALL LOCATE & POTHOLE
(AS NEEDED), ALL EXISTING UTILITIES BEFORE SHORING WALL
CONSTRUCTION BEGINS.
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
RPR
SH
O
R
I
N
G
D
E
S
I
G
N
G
R
O
U
P
77
2
7
C
A
M
I
N
I
T
O
L
I
L
I
A
N
A
,
S
A
N
D
I
E
G
O
C
A
9
2
1
2
9
PH
:
(
7
6
0
)
5
8
6
-
8
1
2
1
r
r
e
e
d
@
s
h
o
r
i
n
g
d
e
s
i
g
n
.
c
o
m
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
PUD 2021-0010
CT 2021-0005
13
538-7A
GR 2022-0029
PROPERTY LINE
147101316222528313419
EXISTING APARTMENT BUILDINGEXISTING APARTMENT BUILDING
RIGHT-OF-WAY
PROPERTY LINE
PROPOSED PERMANENT SHORING
(SEE SHEET SH10 FOR PROFILE)
PROPOSED PERMANENT SHORING
(SEE SHEET SH9 FOR PROFILE)
C
H
I
N
Q
U
A
P
I
N
A
V
E
PROPOSED RESIDENCE
PROPOSED RESIDENCE
EXISTING APARTMENT BUILDING
EXISTING APARTMENT BUILDING
EXISTING APARTMENT BUILDING
XX
LEGEND
T.O.W. = TOP OF SOLDIER BEAM WALL
B.O.W. = BOTTOM OF SOLDIER BEAM WALL
(P) = PROPOSED
(E)= EXISTING
PROPOSED IMPROVEMENTS
IMPROVEMENT SYMBOL
TEMPORARY SOLDIER BEAM
TEMPORARY TIMBER LAGGING
SOLDIER BEAM COUNT
x
SHXDETAIL/SECTION CALLOUTS
BY OTHERS = WORK OUTSIDE SHORING SCOPE
DESIGNATES 6x12 PRESSURE
TREATED LAGGING DF#1
DECLARATION OF RESPONSIBLE CHARGE
I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THE
PERMANENT SHORING OF THIS PROJECT (SHEETS 8-13), AND
THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF
TEMPORARY SHORING AS DEFINED IN SECTION 6703 OF THE BUSINESS
AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT
WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF
PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD
DOES NOT RELIEVE ME, AS ENGINEER OF WORK, MY RESPONSIBILITIES
FOR PROJECT DESIGN.
SHORING DESIGN GROUP NAME: ROY P. REED
7727 CAMINITO LILIANA
SAN DIEGO, CA 92129 SIGNATURE:
PH: (760)586-8121 8
SCOPE OF WORK
PERMANENT SOLDIER BEAM SOLDIER BEAM & LAGGING WALL,
APPROXIMATELY 267 LF AND AN EXPOSED SURFACE AREA TOTALING
1,385 SQUARE FEET, AS SHOWN ON SHEETS SH8-SH13 HEREIN.
A BOUNDARY SURVEY REPORT IS REQUIRED FOR THIS PROJECT.
CONCRETE PLACEMENT WILL NOT BE APPROVED UNTIL A BOUNDARY
SURVEY SHOWING COMPLIANCE TO THE APPROVED PLANS IS
PROVIDED TO THE BUILDING DEPARTMENT.
AM
I
•
,-.... r~ ·\
' I '
I
,,,. ,,.-,,,. ,,,. ,,,. ,,,. ,,,.
:, ' ~1----
---~-
\ \ \ I ' L
I ' I \ \
X
I
I
I
I
L __ '
-"
• -"
' -"
I
II
I
I
J
I
I
I
I \ \
\!~ ------
\ -------'--~--
/---~----7'--
"\
---1 ----f-...,__ __ ..,,__ -A------
..r---------~-...,,,..--__ _ ----
----
---~--
--= -,.
/ '•,,.' ., / -'·•,,, '~>-.,, ,/
I .. "····;,--· '-". d---~::::::5':::4,z'.~'-"-"~~!---L--'-"-"~~~'-"-"'-"-"'-"-"'-"-"'-"-"¥~~~~
d '--
,:------J __
, V ', V ,J ~ \ ~ I ,,...,,,.
----_,,_ __ •_~-'--'.~-~-~-•--~--+,\--""'=-=----=--=--t--~-•,~-~,r: • J1-----+-----rk--+-------+-
\ I J ---I'
" -A I I'
r -1 I
....._ ----7 ~ ..,__ ....... 1· '// . " ,, ~ ,, '•\ ___ ,, '; l ' LJ , 1 lJ :\\,·1· // ,~ .-LJ \I 1,//4 lJ \ 1 ',,;/4 T ,.,--r;; -· .1 . . 5 , , x , • /. \ -' I • ~ I I ,
/-I ",1" -.i· '-----::_•_) ___ " C)1 . ·., --• ----c=r --+-----'1t~==;::=-~~-lJ_ -,---------1:_J ------------. CJ c--:-• c_) / ''l CJ c_: i ~----L~ ·:_·i:
~ ---;'! , -~ ,, 1 ,, l ,, l ,. ' -_;--\ f--L-f'---'"'-L"-CI ~, 1 ~--~
,~11 ,--+~ ------l_ --c-c---( --l';==;=j 7 ·
---,--' ( ' ---------
Ill -'._ -+ -"'1"' ~/" / ---'-'-------I;---: ,-·j X \,
L....J••,I • J "IJ ~ ----------" -
'
---;f ------
~
----\-,. -
' ' ' '
' ' '
I
---. -1-;' ', , /\ I _J ---. -1, L_ --__,,.,_ -\
• -----1~1
~/(r ' ' II / ,.·., ' \ • '
I
' -•Bi--' r--4 ~-.' --= .... ----□
0 -• 0 ·o • 0 . ·-
•
I
0
r---------_i--~-.--------+\ ' ' . I \\
' ' '
r
...L
-o --------·-· · o . .
-" • V
•
•
-"
0 5 10 20 30
GRAPHIC SCALE: 1" = 1 O'
□
I'\
---+-~1--+------M'I, ,\
•
I~ \ _i,\
I
-"
•
SHORING DESIGN GROUP
•
/
Q l---+------+-------------+---+---+---+------11 SHEET 11 CITY OF CARLSBAD I I SHEETS I
GRADING PLANS FOR:
APPROVED: JASON S. GELDERT
ENGlt-lEERING MANAGER RCE 63912 EXPIRES 9 /30 /24 DATE
DATE INITIAL
ENGINEER OF WORK REVISION DESCRIPTION
DATE INITIAL DATE INITIAL
01HER APPROVAL CITY APPROVAL
OWN BY:
I
PROJECT NO. II DRAWING NO.I CHKD BY:
RVWD BY:
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
ROY P. REED R.C.E. 80503 EXP. 3-31-2025 DATE
4/3/2023 R IOFT
A
A NILFOEAT
S
C
N
G
N
LANOFOP
I
I
R
R SS
EE
E
E
DERETSIGER
D
EREP.OR
Exp.
C 80503
3/31/25
LIVIC
Y
50.00'
40.00'
50.00'
40.00'
8 SPACES @ 8'-0" O.C. = 64'-0"
"H"
PERMANENT SOLDIER BEAM
(SEE SCHEDULE FOR SIZE)
SB#1
B.O.W.=
46.00'
48.70'49.50'
SB#2 SB#3 SB#4 SB#5 SB#6 SB#7 SB#8 SB#9
SB#10
SB#11 SB#12
SB#13 SB#14 SB#15 SB#16
SB#17
9'-0"7 SPACES @ 8'-0" O.C. = 56'-0"
T.O.W. = 50.00'
T.O.W. = 52.00'
T.O.W. = 50.00'
T.O.W. = 53.00'
B.O.W. = 47.00'
T.O.W. = 53.00'
B.O.W.=
46.00'
B.O.W.=
46.00'
B.O.W.=
47.00'
~
EXISTING GRADE ALONG
NEIGHBORING PROPERTYEXISTING WALL
(TO BE REMOVED)UNITS #1-3
FOUNDATIONPROPOSED RETAINING WALL
(SEE CIVIL DRAWINGS)
CAST WALL FOUNDATION
INTO BEAM. DRILL/TOURCH
HOLE (1" MAX.) IN SOLDIER
BEAM WEB FOR TRANSVERSE
FOOTING REINFORCEMENT
FINISH GRADE
(BEHIND WALL)
DR
A
W
I
N
G
M
A
T
C
H
L
I
N
E
(S
E
E
S
H
E
E
T
S
H
1
0
)
60.00'60.00'
PROPOSED STORM DRAIN (SEE
CIVIL DRAWINGS), CONNECTION
PER DETAIL 3/SH12, TYPICAL"D"
NEIGHBORING (EXISTING)
RETAINING WALL AND
FENCE (TO REMAIN)FINISH GRADE
(FRONT OF WALL)
7727 CAMINITO LILIANA
SAN DIEGO, CA 92129, (760)586-8121
EG
G
C
W
XXXXXXXXXXXXXXXXXXXXXXXX
X
X
XXX
EXISTING 2 STORY
BUILDING
3' WOOD FENCE
8' WROUGHT IRON
FENCE
6' WOOD FENCE 6' WOOD FENCE
5352
52
5
1
51
49
FL=48.27
FL=47.40
TC=48.74
TC=47.85
OE
OE
OE
OE
OE
OE
COMM POST
SI
D
E
W
A
L
K
WALKWAY
PATIO
49.4
49.7
49.4
49.4
49.3
49.3
49.4
49.4
49.2
49.0
51.4
51.3
51.5
51.4
51.351.2
51.2
51.8
51.6
51.2
50.8
50.4
51.5
51.3
51.8
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
WW
G
G
G
G
G
G
WW
SD
SD
SD
GGGG
(53.4)
FG
(53.8)
FG
(54.0)
FG
(54.2)
FG
1.
0
%
1.
0
%
1.0%
1.
0
%
1.0%1.0%1.0%1.0%
49.0 FG
49.0 FG
48.2 FG48.2 FG
47.7 FG
48.50 FS
53.0 TW
52.0 TW@FG
52.00 TW
51.4 TW@FG
50.0 TW
49.4 TW@FG
47.7 BW
END C-2 WALL
49.1 TW
48.7 TW@FG
47.4 BW
46.3 TF
47.8 BW
10.0'
FYSB
5.
0
'
SY
S
B
8.0'17.0'
25.0'
5.0'
48.62 FS
48.4 TW
48.3 TW@FG
47.8 BW
46.3 TF
EX WALL
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
48.4 FG
48.2 FG
306 CHINQUAPIN AVE
APN 206-020-12-00
48.6 TG
47.9 IE
48.3 TG
47.7 IE
48.1 TG
47.5 IE
47.7 TG
47.1 IE
47.4 TG
46.8 IE
47.2 TG
46.2 IE 49.0 FG
5.
0
%
MI
N
5.
0
%
MI
N
5.
0
%
MI
N
5.
0
%
MI
N
5.
0
%
MI
N
48.5 FG
48.5 FG
5.
0
%
MI
N
52.0 TW
51.5 TW@FG
48.5 BW
5.0%
MIN
50.00 TW
49.1 TW@FG
48.2 BW
EX. RET. WALL
TO BE REMOVEDSIGHT DISTANCE
L = 150 FT
(VM = 20 MPH)
50.00 TW
49.1 TW@FG
48.2 BW
3.
3
'
N 34°00'09" W 274.76'
N
5
5
°
5
8
'
2
7
"
E
70
.
0
0
'
DESIGN BUILD PLANS:
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
RPR
SH
O
R
I
N
G
D
E
S
I
G
N
G
R
O
U
P
77
2
7
C
A
M
I
N
I
T
O
L
I
L
I
A
N
A
,
S
A
N
D
I
E
G
O
C
A
9
2
1
2
9
PH
:
(
7
6
0
)
5
8
6
-
8
1
2
1
r
r
e
e
d
@
s
h
o
r
i
n
g
d
e
s
i
g
n
.
c
o
m
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
PUD 2021-0010
CT 2021-0005
13
538-7A
GR 2022-0029
1. SEE SOLDIER BEAM SCHEDULE ON SHEET 12 FOR SHORING ATTRIBUTES.
2. POTHOLE/FIELD VERIFY EXISTING CONDITIONS PRIOR TO SHORING INSTALLATION.
3. THE NEIGHBORING (EXISTING) WALL FOUNDATION TO REMAIN SHALL NOT BE UNDERMINED DURING EXCAVATION
OR INSTALLATION OF THE PROPOSED PERMANENT SHORING. THE GENERAL CONTRACTOR SHALL FIELD POTHOLE & VERIFY THE LOCATIONS
OF THE EXISTING WALL FOOTINGS TO CONFIRM THE PROPOSED TOP OF WALL AND LATERAL SUPPORT ELEVATIONS SHOWN HEREIN.
NOTES:
~
NEIGHBORING (EXISTING)
WALL & FENCE (TO REMAIN)
1 4 7 10 13
C
H
I
N
Q
U
A
P
I
N
A
V
E
EXISTING APARTMENT BUILDING
1'-8"
4'-10"
DR
A
W
I
N
G
M
A
T
C
H
L
I
N
E
(S
E
E
S
H
E
E
T
S
H
1
0
)
1'-8"
4'-10"
NEIGHBORING WALL
AND STAIRS
PROPOSED RETAINING WALL
(SEE CIVIL DRAWINGS)
CAST WALL FOUNDATION INTO BEAM.
DRILL/TOURCH HOLE (1" MAX.) IN
SOLDIER BEAM WEB FOR TRANSVERSE
FOOTING REINFORCEMENT
PROPOSED STORM DRAIN (SEE
CIVIL DRAWINGS), CONNECTION
PER DETAIL 3/SH12, TYPICAL
EXISTING WALL
(TO BE REMOVED)
20
**EXISTING WALL
(TO BE REMOVED)**
PROPOSED LATERAL
(SEE CIVIL DRAWINGS)
RIGHT-OF-WAY
PROPERTY LINE
PROPOSED RESIDENCE
PROFILE - LOOKING SOUTHWEST
SCALE: 1" = 16'/3 DESIGNATES 6x12 PRESSURE
TREATED LAGGING DF#1
LEGEND:
T.O.W. = TOP OF WALL
B.O.W. = BOTTOM OF WALL
17
PROPOSED PERMANENT
SHORING (TYPICAL)
9
3'-4"
8'-4"
3'-4"3'-4"
2
SH12
1
SH11
1
SH12
**EXISTING WALL TO BE REMOVED**
DEMOLITION OF THE EXISTING WALL SHALL NOT UNDERMINE
THE ADJACENT EXISTING CMU FENCE WALL TO REMAIN.
CONTRACTOR SHALL DEMOLISH WALL & INSTALL SHORING IN
A-B-C SLOTS, IF REQUIRED REMOVALS EXCEED DEPTH OF
ADJACENT FOOTING. ONSITE GEOTECHNICAL ENGINEER
SHALL OBSERVE ALL SHORING & DEMOLITION ACTIVITIES.
UNIT 1
FF= 48.7
PAD= 48.2
UNIT 2
FF= 48.7
PAD= 48.2
UNIT 3
FF= 48.7
PAD= 48.2
UNIT 4
FF= 49.5
PAD= 49.0
SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD
AM
-----------~
L1
•
}'' u //1 I
I I
1-~1
I I
l..! ~
•
- -
I
I I
I I
I I ,-~,
I I
I I
L!-~
:= -E = f-----'--f--~------~-------.. ---: -..;. ...... I'-. • . • • I~-rc\T~,.,,.., .~ c.,.;I .; .4··.' .,
+·.......: .:......,..·, ' :it I ··,--,,f ~ . _·•. ,-I . . ~ . 1--1-11 -· .. _,,,
11,! I I I I I I I I {
I I I I I I I I I
,~
I I I I I I I I I I
-f---~ -~ -~ ,-~,
I I I I I I I I
I I I I I I I I I • I
LL~ L!-~ L!-~ LL~ I I
L._~
.,
.~ i:..----_
'T ■ ■ II r • ■ \ ·■ _. .• ...t-• , I I ':I-I ';.... 1 I . . -~ _....:.. ■ ..Ji • J • • • • • •
!Ill
I
I
I
I
' I
I
I
'
-+-
I
' I
I
I
I
f-----'-
i .·· ··I L ' >
l•
I"
I\
~-·
\j_
-
0
I
-
4 8
~______,~L
'
16
I ---·
I
SCALE: 1"=16/3'
' _/ 11 _' 0
11
, \\ r,
r--I I I II I ~
'
. \\ ' '
' _/ ~,
,-,.___
• ... , \ ◄ ) ..._
l r 'I
◄ ..._ ....
*
' ' ' ' ' '
' ---
' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' '
•
\\--i-
I • '
/
' ' ' ' ' ' ' ' ' ' ' ' ' ' ' '
SHORING DESIGN GROUP r---------'--------,
l-----l--------+------------+--+--+--+------1 L 11 CITY OF CARLSBAD I LJ
l----l------1------------+---+--t---r------t GRADING PLANS FOR:
l----l-----1------------+---+--t---r------t APPROVED: JASON S_ GELDERT
DATE INITIAL
ENGINEER OF WORK
l---+-------l-----------+--+--t--t-------1 ;';EN:;;Gl~t-lE;;:ER:::ING::::::M::::AN:::::AG::'ER;'-;:=RC=:E ~63~91~2~EXP:::IR~ES:::::9::: /,3~0~ /:2~4 ~D~ATE~
OWN BY: --1 PROJECT NO. II DRAWING NO.I f--DA_TE~IN_ITI_AL--+-D_ATE~_INI_TIA____,L CHKD BY: __
O'THER APPROVAL CITY APPROVAL RVWD BY: . REVISION DESCRIPTION
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
X
X
X
XXXXXXXXXXXXXXXXXXXXXXX
X
X
XXX
EXISTING 2 STORY
BUILDING
EXISTING 1 STORY
BUILDING
6' WOOD FENCE 6' WOOD FENCE
6' WOOD FENCE
X
53
52
52
5251.2
51.8
51.6
51.2
52.3
52.5
52.3
52.652.2
52.2
51.5
51.3
51.7
51.4
51.7
51.8
X
X
X
X
X
X
X
XXXX
X
X
X
X
(54.2)
FG
(54.3)
FG
(54.3)
FG
(54.3)
FG
(54.1) FG (54.3)
FG
PAD= 49.0
49.8 FG/HP
49.6 FL
50.0 FG
50.0 FG
49.5 FG48.8 FL 5.0%
1.
3
%
1.
6
%
1.0%
0.
9
%
1
.
0
%
1.0%1.0%1.0%
49.0 FG
49.0 FG
BEGIN C-2 WALL;
53.7 TW
50.0 BW@FG
49.1 TF
53.0 TW
49.0 BW@FG53.0 TW
52.0 TW@FG
5.
0
'
SY
S
B
(48.9 BW @ FG)
(49.8 FS)
(53.6 TW)
(52.9 TW @ FG)
(50.0 BW @ FG)
(54.0 TW)
(53.4 BW)4.
7
'
4.
9
'
EXISTING
STRUCTURE
TO REMAIN
EXISTING
STRUCTURE
TO REMAIN
EXISTING EDGE
OF ASPHALT
49.0 FG
306 CHINQUAPIN AVE
APN 206-020-12-00
EX WALL
TO REMAIN
49.4 TG
48.5 IE
49.3 TG
48.4 IE
49.0 TG
48.1 IE48.6 TG
47.9 IE
48.3 TG
47.7 IE
MIN
50.0 FG
5.
0
%
MI
N
52.4 TW
49.5 BW@FG
48.4 TF
3.
3
'
5.0
%
MI
N
49.5 FG
49.3 FL
49.0 FG
5.
0
%
MI
N
5.
0
%
MI
N
5.
0
%
MI
N
RET. WALL
FOOTING (TYP.)
5.
0
%
MI
N
5.
0
'
53.0 TW
49.5 BW@FG
N 34°00'09" W 274.76'
PROPOSED WALL AND FENCE
COMBINATION NOT TO EXCEED 6'
ROY P. REED R.C.E. 80503 EXP. 3-31-2025 DATE
4/3/2023 R IOFT
A
A NILFOEAT
S
C
N
G
N
LANOFOP
I
I
R
R SS
EE
E
E
DERETSIGER
D
EREP.OR
Exp.
C 80503
3/31/25
LIVIC
Y
7727 CAMINITO LILIANA
SAN DIEGO, CA 92129, (760)586-8121
T.O.W. = 53.00'
50.00'
40.00'
60.00'
50.00'
40.00'
60.00'
SB#17 SB#18
SB#19 SB#20 SB#21 SB#22 SB#23
SB#24
SB#25 SB#26
SB#27 SB#28 SB#29
SB#30 SB#31 SB#32 SB#33 SB#34
DR
A
W
I
N
G
M
A
T
C
H
L
I
N
E
(S
E
E
S
H
E
E
T
S
H
9
)
EN
D
P
E
R
M
A
N
E
N
T
SO
L
D
I
E
R
B
E
A
M
W
A
L
L
B.O.W. = 47.00'
B.O.W.=
47.00'
B.O.W.=
48.00'
B.O.W.=
48.00'
B.O.W.=
48.00'
8'-9"7 SPACES @ 8'-0" O.C. = 56'-0" 9'-0"8 SPACES @ 8'-0" O.C. = 64'-0"
T.O.W. = 53.00'T.O.W. = 53.00'
T.O.W. = 54.00'PROPOSED RETAINING WALL
(SEE CIVIL DRAWINGS)
CAST WALL FOUNDATION
INTO BEAM. DRILL/TOURCH
HOLE (1" MAX.) IN SOLDIER
BEAM WEB FOR TRANSVERSE
FOOTING REINFORCEMENT
NEIGHBORING (EXISTING)
RETAINING WALL AND
FENCE (TO REMAIN)
~
49.50'50.50'
EXISTING GRADE ALONG
NEIGHBORING PROPERTY
FINISH GRADE
(BEHIND WALL)
FINISH GRADE
(FRONT OF WALL)
PERMANENT SOLDIER BEAM
(SEE SCHEDULE FOR SIZE)
PROPOSED STORM DRAIN (SEE
CIVIL DRAWINGS), CONNECTION
PER DETAIL 3/SH12, TYPICAL
DESIGN BUILD PLANS:
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
RPR
SH
O
R
I
N
G
D
E
S
I
G
N
G
R
O
U
P
77
2
7
C
A
M
I
N
I
T
O
L
I
L
I
A
N
A
,
S
A
N
D
I
E
G
O
C
A
9
2
1
2
9
PH
:
(
7
6
0
)
5
8
6
-
8
1
2
1
r
r
e
e
d
@
s
h
o
r
i
n
g
d
e
s
i
g
n
.
c
o
m
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
PUD 2021-0010
CT 2021-0005
13
538-7A
GR 2022-0029
17 20 23 26 29 32 34
NEIGHBORING (EXISTING)
WALL & FENCE (TO REMAIN)
EXISTING APARTMENT BUILDING
DR
A
W
I
N
G
M
A
T
C
H
L
I
N
E
(S
E
E
S
H
E
E
T
S
H
9
)
1'-7"
4'-10"
PROPOSED RETAINING WALL
(SEE CIVIL DRAWINGS)
CAST WALL FOUNDATION INTO BEAM.
DRILL/TOURCH HOLE (1" MAX.) IN
SOLDIER BEAM WEB FOR TRANSVERSE
FOOTING REINFORCEMENT
PROPOSED STORM DRAIN (SEE
CIVIL DRAWINGS), CONNECTION
PER DETAIL 3/SH12, TYPICAL
**EXISTING WALL
(TO BE REMOVED)**PROPERTY LINE
PROPOSED RESIDENCE
PROPERTY LINE1'-8"
4'-10"
PROPOSED PERMANENT
SHORING (TYPICAL)
UNIT 5 UNIT 6 UNIT 7 UNIT 9UNIT 8
EXISTING APARTMENT BUILDING
1. SEE SOLDIER BEAM SCHEDULE ON SHEET 12 FOR SHORING ATTRIBUTES.
2. POTHOLE/FIELD VERIFY EXISTING CONDITIONS PRIOR TO SHORING INSTALLATION.
3. THE NEIGHBORING (EXISTING) WALL FOUNDATION TO REMAIN SHALL NOT BE UNDERMINED DURING EXCAVATION
OR INSTALLATION OF THE PROPOSED PERMANENT SHORING. THE GENERAL CONTRACTOR SHALL FIELD POTHOLE & VERIFY THE LOCATIONS
OF THE EXISTING WALL FOOTINGS TO CONFIRM THE PROPOSED TOP OF WALL AND LATERAL SUPPORT ELEVATIONS SHOWN HEREIN.
NOTES:
PROFILE - LOOKING SOUTHWEST
SCALE: 1" = 16'/3 DESIGNATES 6x12 PRESSURE
TREATED LAGGING DF#1
LEGEND:
T.O.W. = TOP OF WALL
B.O.W. = BOTTOM OF WALL
10
4'-4"3'-4"3'-4"
2
SH12
2
SH11
1
SH12
**EXISTING WALL TO BE REMOVED**
DEMOLITION OF THE EXISTING WALL SHALL NOT UNDERMINE
THE ADJACENT EXISTING CMU FENCE WALL TO REMAIN.
CONTRACTOR SHALL DEMOLISH WALL & INSTALL SHORING IN
A-B-C SLOTS, IF REQUIRED REMOVALS EXCEED DEPTH OF
ADJACENT FOOTING. ONSITE GEOTECHNICAL ENGINEER
SHALL OBSERVE ALL SHORING & DEMOLITION ACTIVITIES.
SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD
AM
/ / I/ /
; ; ; ; ;I
-I
I I I .,
I I
I ----I I I \. ·-
!
--....
I I I I I I I I I
I
I I I I I I I I I I \ ...
!
I !
~ I / ///,-
-· -' I f--/ -•. / -' ---! _r= -\ -. f----------------/->--------f-f--- --f---f--. . -~ . . . ,-s;= ~------------__ ___. __ ----. . ..,__ -~ : -~ . . . .. ' . • • ·, .. . . -. ..
.. : . .q· .II . -. . .. • • . • -• . 4 ·• I • I • . -. • ~-•· . . •• • .• .., . 4_ .. .
' . •• . 1'~~ 4 . cf-~ I . . . • I I . ~. ·. ··4 . ~!-.. , . •/ .. ~ -. • • • I I ~I L !.__. _ __k l -~!-0.; ..Jj • I :I I I; ;I I I: 111 I; ~1JT I I I I LJ 1~ ... I I : -. . . f----· -·--·;-",-· _· -&..j± -1 1/1 I I . - I I I I I I I I I I I I I I I I
I .
I I I I I I I I I I I I I I I I I I ~ -Y I I I I I I I I I I I I T' I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I -1 I-~1 1--1 1- -1 I--I I- -I I--I -r -1 1-~I - -- --~ -~ -I--I I--I I--I I--I I- -I I I I I I I I I I I LJ.LJ I I I I LJ u LLLJ LJ.LJ I. I I I I I I I I I I I I I I I I I I I I I I I I I I I L! ~ L! ~ L! ~ L! ~ L! ~ I I I I LL~ L!-~ L!-~ LL~ L!-~ L:-~ L:-~
L:-~ L:-~
-
-
1\ .-I -
I .-
./
_,/'/ I
' ./ I ' d; ~ \ ' l) I / I> . ' d L] ./ .Q _! -.. = I I L]
v7 ./ ! \ di / \ -IT ! I> I I> i 0 0 •,
0 -~-~ 0 . / i '• • ·d-____, ' . . •• i. • ' . t -~---1111 " 1111 ~ .l.... ~ ... -~--1.__________,_ ·--' f~Gi •...l... ., . -~ -------.. ... •-1 .... ~ - -----~ -. ~ --~ ~-=---• -/~ ...--_ - -._..--~""t::::;::I IL---.. --:-""a ~ -=-----• • -;I ~-I I • • • • • • -• • -• • I I []--t ./ I ' , " --
t
1--~ ~ -~ IQ • IQ] ' :) -J • -• V 1.,.~ . . // ,.._ ( 7' -', -. --/ ' --' ii ' ' ---' ,I J I --' ' 1/// ' • '-.. ' ' " -\ ' ~ '-r---_c . ' ' \\ ! ' j ' , ' t \I/,~ "' I ◄ I ' ' --,. ' ' "'--~11 --------\ ... -----' ) ~ • --' J"\J .....--' I ---------'
I
h Ut-! -' -----J --', , 'I ' ' -. l"i ' ◄ ' ' ,. ' ' '-', ' SHORING DESIGN GROUP 1 ' ' ' .. ./ '
-------
' ' ' --' y· ,, ~ ---..:.. "11111 ' ' -
' \ ---' --' ' ' --' ' -' --'
-' ---' --' ' ' --', -,---'
------
' ; -'
-------r------
-----------I
-----
--------} -------_<,✓-"
I SHEET 11 CITY OF CARLSBAD 11 SHEETS I ,_,, ,,, ,_ __ . __ ,
GRADING PLANS FOR: ,,.: \\\Ing S~ -:_,,
•: <:::) <.. ~-~· ,, :::: ~ ,,
11 -~ --l.l 0 4 B 16 II == ::, fl APPROVED: JASON S. GELDERT I '\.l u-1 o ~# I
SCALE: 1"=16/3' ,1, ' ,~, ~ ) ( _,) ENGINEERING MANAGER RCE 63912 EXPIRES 9 /30 /24 DATE "\..111 ,1'-" * 7* DWN BY:
I
PROJECT NO. II DRAWING NO.I "' ,,; '-DAlE INITIAL DAlE INITIAL DAlE INITIAL CHKD BY: ,_.._,.__ re'~ REVISION DESCRIPTION RVWD BY: .;;, ~ ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
ROY P. REED R.C.E. 80503 EXP. 3-31-2025 DATE
4/3/2023 R IOFT
A
A NILFOEAT
S
C
N
G
N
LANOFOP
I
I
R
R SS
EE
E
E
DERETSIGER
D
EREP.OR
Exp.
C 80503
3/31/25
LIVIC
Y
DESIGN BUILD PLANS:
7727 CAMINITO LILIANA
SAN DIEGO, CA 92129, (760)586-8121
SHORING SECTION ALONG SOUTH PROPERTY LINE
N.T.S.
NOTES: 1. POTHOLE/FIELD VERIFY ALL EXISTING & PROPOSED UTILITIES PRIOR TO SHORING INSTALLATION.
2. SEE SOLDIER BEAM SCHEDULE ON SHEET 12 FOR VARIABLES "H" & "D".
"H"
"D"
PL
1
SH11
PROPERTY LINE
PERMANENT SOLDIER BEAM
(SEE SCHEDULE FOR SIZE)
40.00'
50.00'
60.00'
(E) 2-STORY BUILDING
1'-8"
4'-10"
NEIGHBORING (EXISTING) RETAINING
WALL AND FENCE (TO REMAIN)
EXISTING WALL
(TO BE REMOVED)
PROPOSED FOUNDATION
40.00'
50.00'
60.00'
40.00'
50.00'
60.00'
SHORING SECTION ALONG SOUTH PROPERTY LINE
N.T.S.
NOTES: 1. POTHOLE/FIELD VERIFY ALL EXISTING & PROPOSED UTILITIES PRIOR TO SHORING INSTALLATION.
2. SEE SOLDIER BEAM SCHEDULE ON SHEET 12 FOR VARIABLES "H" & "D".
"H"
"D"
PL
2
SH11
PROPERTY LINE
PERMANENT SOLDIER BEAM
(SEE SCHEDULE FOR SIZE)
(E) 2-STORY BUILDING
1'-7"
4'-10"
NEIGHBORING (EXISTING) RETAINING
WALL AND FENCE (TO REMAIN)
EXISTING WALL
(TO BE REMOVED)
PROPOSED FOUNDATION
40.00'
50.00'
60.00'
**EXISTING WALL TO BE REMOVED**
DEMOLITION OF THE EXISTING WALL SHALL NOT UNDERMINE
THE ADJACENT EXISTING CMU FENCE WALL TO REMAIN.
CONTRACTOR SHALL DEMOLISH WALL & INSTALL SHORING IN
A-B-C SLOTS, IF REQUIRED REMOVALS EXCEED DEPTH OF
ADJACENT FOOTING. ONSITE GEOTECHNICAL ENGINEER
SHALL OBSERVE ALL SHORING & DEMOLITION ACTIVITIES.
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
RPR
SH
O
R
I
N
G
D
E
S
I
G
N
G
R
O
U
P
77
2
7
C
A
M
I
N
I
T
O
L
I
L
I
A
N
A
,
S
A
N
D
I
E
G
O
C
A
9
2
1
2
9
PH
:
(
7
6
0
)
5
8
6
-
8
1
2
1
r
r
e
e
d
@
s
h
o
r
i
n
g
d
e
s
i
g
n
.
c
o
m
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
PUD 2021-0010
CT 2021-0005
13
538-7A
GR 2022-0029
11
AM
/
......... , ..
/
\
I
SHORING DESIGN GROUP
1----1----+------------+--+--+--+-------t L 11 CITY OF CARLSBAD I LJ
1-----+--+---------------+----+--+------t-------t GRADING PLANS FOR:
APPROVED: JASON S. GELDERT
') (
-----* ENGlt-lEERING MANAGER RCE 63912 EXPIRES 9/30/24 DATE
DATE INITIAL
ENGINEER OF WORK REVISION DESCRIPTION
DATE INITIAL DATE INITIAL
O"THER APPROVAL CITY APPROVAL
OWN BY: ---1 CHKD BY: __ _
RVWD BY: .
PROJECT NO. II DRAWING NO.I
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
ROY P. REED R.C.E. 80503 EXP. 3-31-2025 DATE
4/3/2023 R IOFT
A
A NILFOEAT
S
C
N
G
N
LANOFOP
I
I
R
R SS
EE
E
E
DERETSIGER
D
EREP.OR
Exp.
C 80503
3/31/25
LIVIC
Y
DESIGN BUILD PLANS:
7727 CAMINITO LILIANA
SAN DIEGO, CA 92129, (760)586-8121
FINISH GRADE (SEE CIVIL)
(B.O.W., SEE ELEVATION)
"H"
"D"
Dshaft
TIMBER LAGGING
(SEE ELEVATION)
1.5 SACK SLURRY SHAFT
BACKFILL (T.O.W. TO B.O.W.)
4,000 PSI CONCRETE SHAFT
BACKFILL (BALANCE OF SHAFT)
PERMANENT CANTILEVERED SOLDIER BEAM (TYP.)
N.T.S.
NOTES: 1. FIELD VERIFY ALL EXISTING & PROPOSED STRUCTURES PRIOR TO SHORING INSTALLATION.
2. SEE SOLDIER BEAM SCHEDULE ON SHEET 12 FOR VARIABLES "H", "D" AND "Dshaft".
3.TOP & BOTTOM OF WALL CONDITIONS VARY, SEE PLAN & ELEVATION FOR GRADE CONDITIONS.
EPOXY COATED SOLDIER BEAM
SEE DETAIL 3/SH12 FOR EXTENTS
PERMANENT SOLDIER BEAM PLAN DETAIL (TYPICAL)
N.T.S.
DRILL SHAFT (SEE BEAM
SECTIONS FOR BACKFILL
MATERIAL)
SEE ELEVATION FOR SPACING
FILL VOIDS BEHIND LAGGING WITH
COMPACTED SOIL AS APPROVED BY
THE GEOTECHNICAL ENGINEER
EPOXY COATED
SOLDIER BEAM
SEE 3/SH12
FOR EXTENTS
20d COMMON GALVANIZED NAILS
FOR LAGGING INSTALLATION (TYP.)
2" (MIN.)
BEARING
TIMBER LAGGING
(SEE ELEVATIONS)
48"
12"± MIN.
SEE PROFILE
TOP OF WALL (T.O.W.)
SEE PROFILE VIEW
DRAIN GRATE & 4" SUBDRAIN
(MID-BAY, SEE DETAIL 3/SH12)
PERMANENT CANTILEVERED SOLDIER BEAM DRAINAGE DETAIL
N.T.S.
3" CLR
24" (MIN)
4,000 PSI CONCRETE TOE
(TYP II/V, W/C = 0.50)
1.5 SACK SLURRY
SHAFT BACKFILL
6x12 DF#1 PRESSURE
TREATED LAGGING
4"Ø PVC PIPE CONNECTED
TO SUBDRAIN (BY OTHERS)
GEOTEXTILE
PVC CONNECTOR PIPE
SEAL CUT-IN JOINT
GEOCOMPOSITE DRAIN
PREFABRICATED DRAIN GRATE
STRIP
WITH DUCT TAPE
DRAIN GRATE ISOMETRIC VIEW
FINISH GRADE
(PER CIVIL DWG.)
12"
MIN.
48" WIDE, MIRADRAIN 6000 DRAINAGE BOARD STRIPS,
CENTERED BETWEEN SOLDIER BEAMS VERTICALLY WITH 48"
WIDE CONTINUOUS STRIPS CENTERED ABOUT WEEP HOLES.
(PLACE GEOFABRIC SIDE AGAINST SOIL BACKFILL)
EPOXY PAINT FULL SECTION
EXTENDING FROM TOP OF PILE TO
24" BELOW TOP OF CONCRETE TOE
48" WIDE, MIRADRAIN 6000 DRAINAGE BOARD STRIPS,
CENTERED BETWEEN SOLDIER BEAMS VERTICALLY WITH 48"
WIDE CONTINUOUS STRIPS CENTERED ABOUT WEEP HOLES.
(PLACE GEOFABRIC SIDE AGAINST SOIL BACKFILL)
NEIGHBORING (EXISTING) RETAINING
WALL AND FENCE (TO REMAIN)
PROPERTY LINE
PL
SOLDIER BEAM SCHEDULE
NOTES: 1. FIELD VERIFY ALL EXISTING & PROPOSED STRUCTURES PRIOR TO SHORING INSTALLATION.
2. FIELD SURVEY PROPERTY LINE & VERIFY ALL CLEARANCES IN THE FIELD PRIOR TO INSTALLATION.
2%
INVERT PER
CIVIL DWGS.
SITE ADDRESS: 330 CHINQUAPIN PROJECT # 22150
BASED ON THE PROJECT SCOPE, PLEASE IDENTIFY THE ELEMENTS AND/OR CONNECTIONS THAT
REQUIRE STRUCTURAL OBSERVATION. SPECIFY THE INTERVAL OR STAGE OF CONSTRUCTION.
TO BE COMPLETED BY THE DESIGN ENGINEER INCLUDED ON CONSTRUCTION DOCUMENTS
TYPE STRUCTURAL ELEMENTS AND/OR
CONNECTION TO BE OBSERVED STAGE OF CONSTRUCTION
STRUCTURAL OBSERVATIONS
FO
U
N
D
A
T
I
O
N
S
WA
L
L
F
A
C
I
N
G
S
STEEL CONFORMANCE AISC 360
MAT FOUNDATION, PRE-STRESED CONC.
OTHER
SHOTCRETE
MASONRY
SHOTCRETE & MASONRY JOINTS
OTHER
FINAL OBSERVATION & REPORT
PILE LAYOUT/VERIFICATION OF PLACEMENT
1. STRUCTURAL OBSERVATION DOES NOT WAIVE THE RESPONSIBILITY FOR THE REQUIRED INSPECTION BY THE
CITY OF CARLSBAD.
2. THE STRUCTURAL OBSERVER SHALL SUBMIT A WRITTEN STATEMENT TO INSPECTION SERVICES THAT THE SITE
VISITS HAVE BEEN MADE AND IDENTIFYING AND REPORTED DEFICIENCIES THAT TO THE BEST OF THE
STRUCTURAL OBSERVE'S KNOWLEDGE HAVE NOT BEEN RESOLVED.
OBSERVATIONS NOTED IN FINAL REPORT
1
SH12
2
SH12
3
SH12
3
SH12
EXISTING GRADE ALONG
NEIGHBORING PROPERTY
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
RPR
SH
O
R
I
N
G
D
E
S
I
G
N
G
R
O
U
P
77
2
7
C
A
M
I
N
I
T
O
L
I
L
I
A
N
A
,
S
A
N
D
I
E
G
O
C
A
9
2
1
2
9
PH
:
(
7
6
0
)
5
8
6
-
8
1
2
1
r
r
e
e
d
@
s
h
o
r
i
n
g
d
e
s
i
g
n
.
c
o
m
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
PUD 2021-0010
CT 2021-0005
13
538-7A
GR 2022-0029
12
AM
--
! 1 Toe Total Toe ---+------~----------+----~---------From To Beam ' Beam Shored I Depth Beam Diameter
-----------~-------------------➔-----Beam Beam Qty I Section I Height I Length ---~-----------t-----L----~---------' H , D H+D Dshaft
-----
ft ft ft in
1 f 9 9 ··l \1,(12x 40 ·l···· 4.0 ·····;·····10.o ····I·· 14.0 ..... 24
······· ··1 o ········· ········· 1·0·· ······· ········· 1· ······· :· w 1i·x.·4o 1 ······· ·6:o ········· ······· 1·· ·1 iO ········ ········· 19·:o·· ·+ ········· ··24 ········· ·······
---~-----~ ----t-----'----~---------11 12 2 : W 12 X 40 6,0 I 12.0 18 .0 24
.. ---.. --... --JI ... ---... --... --...... ---... ---.JI ---... -
13
14 16
........ 1 . .7 .. + .. 1~········ ........ ~ ....... i .Y! .. 1~.~ .. 4.?.j ............ 6.:0 ....... + ·······1·~•? ....... I·· •• 1?•? ..................... ~4 ... .
19 23 5 ' W 12 X 40 6.0 , 12.0 18 .0 24
-----------L-----~-----,---------➔-----
1
-= = -_1= = --= = --= ~ --= = -
24 24 5,0 , 10.0 15.0 24
-, ---·.,,r 7i1
,,.-t ,_ . -1~
-II J 11 I:
25 26 2 ;W12x40 • 5.0 I 13.0 18 .0 24 ---= ------+.a---= -r-= ---= ---= ---= 4'--= --
27 29 3 W12x40 5.0 1 10.0 15.0 24
····································+······························ ........................... , .................................... ·························································+··············································+···············································I·········································· .... . 30 34 5 W 12 X 40 6.0 , 12.0 18.0 24
-----------~-----~--------------➔-----. I
I
\
□
□
□ SHORING DESIGN GROUP .--------------,
□
□
□
□
□
FINAL □
l---+----+------------+---+---+---+------11 SHEET 11 CITY OF CARLSBAD I I SHEETS I
GRADING PLANS FOR:
APPROVED: JASON S. GELDERT
ENGlt-lEERING MANAGER RCE 63912 EXPIRES 9 /30 /24 DATE
DATE INITIAL
ENGINEER OF WORK REVISION DESCRIPTION
DATE INITIAL DATE INITIAL
01HER APPROVAL CITY APPROVAL
OWN BY:
I
PROJECT NO. II DRAWING NO.I CHKD BY:
RVWD BY:
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023
ROY P. REED R.C.E. 80503 EXP. 3-31-2025 DATE
4/3/2023 R IOFT
A
A NILFOEAT
S
C
N
G
N
LANOFOP
I
I
R
R SS
EE
E
E
DERETSIGER
D
EREP.OR
Exp.
C 80503
3/31/25
LIVIC
Y
DESIGN BUILD PLANS:
7727 CAMINITO LILIANA
SAN DIEGO, CA 92129, (760)586-8121
GENERAL NOTES
1. CONSTRUCTION PLANS AND CALCULATIONS CONFORM TO THE REQUIREMENTS OF THE 2019 CALIFORNIA BUILDING CODE.
2. PERMANENT SHORING CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE STATE OF
CALIFORNIA CONSTRUCTION SAFETY ORDERS (CAL-OSHA).
3. HEAVY LOADS SUCH AS CRANES OR CONCRETE TRUCKS IS PROHIBITED WITHIN 10 FEET OF THE TOP OF EXCAVATION
EXCEPT WHERE THE SHORING DESIGN PROVIDES FOR THE PROPOSED STRUCTURE.
4. AN UNDERGROUND SERVICE ALERT MUST BE OBTAINED 2 DAYS BEFORE COMMENCING ANY EXCAVATION.
5. THE OWNER OR THE REGISTERED PROFESSIONAL IN RESPONSIBLE CHARGE ACTING AS THE OWNER'S AGENT SHALL EMPLOY
ONE OR MORE APPROVED AGENCIES TO PERFORM INSPECTIONS DURING CONSTRUCTION.
6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL INSPECTION SERVICES, TESTING & NOTIFICATIONS.
7. ALL PERMITS SHALL BE PROCURED AND PAID FOR BY THE OWNER OR GENERAL CONTRACTOR.
8. ALL MONITORING PROVIDED IN THESE PLANS HEREIN, SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
9. PERMANENT SHORING IN THESE PLANS HAS BEEN ALIGNED WITH RESPECT TO THE EXISTING & PROPOSED FEATURES, AS
PROVIDED. ACTUAL FIELD LOCATION OF THE SHORING WALL SHALL BE ESTABLISHED USING ACCURATE HORIZONTAL
CONTROL & COORDINATED TO FOLLOW THE PLANNED LOCATION OF THE PROPOSED IMPROVEMENTS. REPORT ANY
VARIATIONS TO THE ENGINEER OF RECORD PRIOR TO COMMENCEMENT OF WORK.
10. THE GENERAL CONTRACTOR OR OWNER SHALL LOCATE ALL EXISTING UTILITIES AND STRUCTURES PRIOR TO EXCAVATION
AND THE INSTALLATION OF SHORING.
11. THE GENERAL CONTRACTOR SHALL CONFIRM THAT THE PROPOSED SHORING DOES NOT CONFLICT WITH FUTURE
IMPROVEMENTS PRIOR TO INSTALLATION.
12. THE GENERAL CONTRACTOR SHALL PROVIDE MEANS TO PREVENT SURFACE WATER FROM ENTERING THE EXCAVATION OVER
THE TOP OF SHORING BULKHEAD.
13. INSTALLATION OF SHORING AND EXCAVATION SHALL BE PERFORMED UNDER CONTINUOUS OBSERVATION AND APPROVAL OF
THE GEOTECHNICAL ENGINEER AND AUTHORITY HAVING JURISDICTION.
14. ALTERNATIVE SHAPES, MATERIAL AND DETAILS CANNOT BE USED UNLESS REVIEWED AND APPROVED BY THE SHORING
ENGINEER.
15. SEE CIVIL DRAWINGS FOR FINISH SURFACE ELEVATIONS & DRAINAGE. ADDITIONALLY, THE ARCHITECT SHALL APPROVE THE
TOP OF WALL ELEVATIONS SHOWN PER PLAN, PRIOR TO FABRICATION.
16. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS, TO VERIFY CONDITIONS AT THE
JOB SITE AND TO CROSS-CHECK DETAILS AND DIMENSIONS WITHIN THE SHORING PLANS WITH RELATED REQUIREMENTS ON
THE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND ALL OTHER PERTINENT DRAWINGS BEFORE PROCEEDING WITH
CONSTRUCTION.
17. ALL SOIL BACKFILL & COMPACTION SHALL BE OBSERVED & PERFORMED TO THE REQUIREMENTS OF THE GEOTECHNICAL
ENGINEER OF RECORD.
SHORING INSTALLATION PROCEDURE
1. FIELD SURVEY DRILL HOLES & SHORING ALIGNMENT ACCORDING TO WALL DIMENSIONS & DATA SHOWN OR AS DETERMINED
OTHERWISE IN THE FIELD & APPROVED BY THE SHORING ENGINEER. NOTE: DEMOLITION OF THE EXISTING WALL SHALL
NOT UNDERMINE THE ADJACENT CMU FENCE WALL TO REMAIN. CONTRACTOR SHALL DEMOLISH WALL & INSTALL SHORING
IN A-B-C SLOTS, IF REQUIRED REMOVALS EXCEED DEPTH OF ADJACENT FOOTING. ONSITE GEOTECHNIAL ENGINEER SHALL
OBSERVE ALL SHORING & DEMOLITION ACTIVITIES.
2. DRILL VERTICAL SHAFTS TO THE EMBEDMENT DEPTH AND DIAMETERS SHOWN. ALLOWABLE PLACEMENT TOLERANCE SHALL
BE 2" IN OR 2" OUT OR AS OTHERWISE AUTHORIZED BY THE SHORING ENGINEER. SOLDIER BEAMS SHALL BE DRILLED & SET
EVERY OTHER HOLE, UNLESS AUTHORIZED BY THE ONSITE GEOTECHNICAL ENGINEER.
3. INSTALL SOLDIER BEAMS ACCORDING TO THE DETAILS & SPECIFICATIONS SHOWN IN PLAN. IF NECESSARY, CASING OR
OTHER METHODS SHALL BE USED TO PREVENT LOSS OF GROUND OR COLLAPSE OF THE HOLE.
4. START EXCAVATION AFTER CONCRETE HAS CURED FOR A MINIMUM OF (3) THREE DAYS.
5. INSTALL LAGGING & DRAINAGE BOARD BETWEEN INSTALLED SOLDIER BEAMS IN AN A-B-C SEQUENCE, WITH LIFTS NO
GREATER THAN 5'-0", OR AS OTHERWISE AUTHORIZED BY THE GEOTECHNICAL ENGINEER.
6. BACKFILL ALL VOIDS BEHIND LAGGING WITH COMPACTED SOIL ACCORDING TO THE SPECIFICATIONS OF THE GEOTECHNICAL
ENGINEER OF RECORD
7. REPEAT STEPS 5-6 UNTIL BOTTOM OF EXCAVATION IS REACHED.
MONITORING
1. MONITORING SHALL BE ESTABLISHED AT THE TOP OF SOLDIER BEAMS SELECTED BY THE ONSITE
GEOTECHNCIAL REPRESENTATIVE AND SURVEYOR AT INTERVALS ALONG THE WALL AS CONSIDERED
APPROPRIATE.
2. THE GENERAL CONTRACTOR SHALL PERFORM A PRECONSTRUCTION SURVEY INCLUDING
PHOTOGRAPHS & VIDEO OF THE EXISTING SITE CONDITIONS.
3. MAXIMUM THEORETICAL SOLDIER BEAM DEFLECTION IS 0.50-INCH. IF THE TOTAL CUMULATIVE
HORIZONTAL OR VERTICAL MOVEMENT (FROM START OF CONSTRUCTION) EXCEEDS THIS LIMIT, ALL
EXCAVATION ACTIVITIES SHALL BE SUSPENDED AND INVESTIGATED BY THE SHORING ENGINEER FOR
FURTHER ACTIONS (AS NECESSARY).
4. LONG TERM MONITORING AND MAINTENANCE OF THE WOOD LAGGING AND FUTURE REPLACEMENT
THERE OF SHALL BE THE SOLE RESPONSIBILITY OF THE PROPERTY OWNER.
MATERIAL SPECIFICATIONS
STRUCTURAL STEEL
1. STRUCTURAL STEEL (WIDE FLANGES) SHALL CONFORM TO THE REQUIREMENTS ASTM A-572 OR ASTM
A-992 (GRADE 50).
2. MISCELLANEOUS STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-36, ASTM A-572 (GRADE 50)
OR ASTM A-992.
3. TRENCH PLATES (LAGGING) SHALL CONFORM TO THE REQUIREMENTS FO ASTM A-36.
STRUCTURAL & LEAN CONCRETE
A. STRUCTURAL CONCRETE:
1. STRUCTURAL CONCRETE (DRILL SHAFT TOE BACKFILL) SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH
OF 4,000PSI AT 28-DAYS, W/C=0.50, TYPE II/V CEMENT.
2. CONCRETE MIX SHALL BE IN ACCORDANCE WITH 2019CBC & ACI 318 TO MEET THE FOLLOWING:
A.MAXIMUM 1-INCH HARDROCK CONCRETE CONFORMING TO ASTM C-33.
B. TYPE II/V NEAT PORTLAND CEMENT CONFORMING TO ASTM C-150.
C.SLUMP NO GREATER THAN 5-INCHES.
B. LEAN CONCRETE (SLURRY)
1. LEAN SAND SLURRY MIX SHALL CONTAIN A MINIMUM OF 1.5 SACK TYPE II CEMENT PER CUBIC YARD.
TIMBER
1. 6x12 TIMBER LAGGING SHALL BE SAWN DOUGLAS FIR LARCH NO. 1 OR BETTER.
2. TIMBER LAGGING SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA U1 USE CATEGORY 4B.
TREAT CUT ENDS OF 6x12 LAGGING WITH WATER REPELLENCY CONTAINING NO ARSENIC OR CHROMIUM.
WELDING
1. ELECTRIC ARC WELDING PERFORMED BY QUALIFIED WELDERS USING E70XX ELECTRODES OR
CONTINUOUS WIRE FEED.
2. SPECIAL INSPECTION IS REQUIRED FOR ALL FIELD WELDING.
GEOCOMPOSITE DRAINAGE BOARDS
1. GEOCOMPOSITE DRAINAGE BOARD SHALL BE MIRADRAIN 6000 BY MIRADRI (OR APPROVED EQUIVALENT)
CORROSION PROTECTION (STEEL)
1. EPOXY PAINT: SOLDIER BEAM EPOXY COATING SHALL BE BITUMASTIC COAL-TAR EPOXY (OR EQUAL).
TWO COATS SHALL BE APPLIED FOR A TOTAL DRY FILM THICKNESS OF 16 MILS. ALL STEEL SURFACES
SHALL BE BLAST WITH SSPC-SP 10 (NEAR WHITE) BEFORE COATING IS APPLIED.
STATEMENT OF SPECIAL INSPECTIONS
DESIGN CRITERIA
1. SOIL DESIGN DATA IS BASED ON THE RECOMMENDATIONS PROVIDED
IN THE FOLLOWING GEOTECHNICAL REPORTS:
A. REPORT OF PRELIMINARY GEOTECHNICAL INVESTIGATION
PROPOSED CHINQUAPIN COAST HOMES
330 CHINQUAPIN AVENUE
CARLSBAD, CALIFORNIA
PREPARED BY: GEI, DATED 10-28-21
2. LOAD COMBINATIONS, CBC 1605.3.1
D+L+H
3.SOIL DESIGN PRESSURES
A. PASSIVE EARTH PRESSURE = 275PSF/FT
B.LATERAL EARTH PRESSURE = 38PSF/FT + 8H
C. BUILDING SURCHARGE = 600PLF LINE LOAD
D. WALL SURCHARGE = 450PLF LINE LOAD
REVIEWED BY:
DATEINSPECTOR
DATE
"AS BUILT"
ENGINEERING DEPARTMENT
RCE EXP.
RPR
SH
O
R
I
N
G
D
E
S
I
G
N
G
R
O
U
P
77
2
7
C
A
M
I
N
I
T
O
L
I
L
I
A
N
A
,
S
A
N
D
I
E
G
O
C
A
9
2
1
2
9
PH
:
(
7
6
0
)
5
8
6
-
8
1
2
1
r
r
e
e
d
@
s
h
o
r
i
n
g
d
e
s
i
g
n
.
c
o
m
CHINQUAPIN COASTAL HOMES
330 CHINQUAPIN AVENUE
PUD 2021-0010
CT 2021-0005
13
538-7A
GR 2022-0029
13
AM
*
VERIFICATION AND INSPECTION
1. Verifying use of required design mix.
2. At the lime fresh concrete is sampled to
fabricate specimens for strength tests,
perform slump and air content tests, and
determine the temperature of the concrete.
3. Inspection of concrete & shotcrete placement
for proper applicatoin techniques.
4. Inspection of maintenance of specified
curing temperature and techniques.
5. Material verification of structural steel
a. For structural steel, identification markings
to conform to AISC 360.
b. Manufacturer's certified test reports
6. Material Identification of timber
a. identification of perserative
VERIFICATION AND INSPECTION (OTHER ITEMS)
7. Observe drilling operations and maintain
complete and accurate records for each
element.
8. Verify placement locations and plumbness,
confirm element diameters, bell diameters
(if applicable), lengths, embedment into
bedrock (if applicable) and adequate end
bearing strata capacity. Record concrete
and grout values.
9. Verify excavations are extended to the
proper depth.
10. Verify use of proper materials, densities
and lift thickness during placement and
compaction of compacted fill.
11. Verify proper corrosion protection
for all steel elements
CONTINOUS PERIODIC
X
X
X
X
X
X
X
X
X
X
X
X
SHORING DESIGN GROUP
REFERENCE
CBC 1904.1, ACl-318 26.4.3 & 26.4.4
CBC 1908.10, ASTM C172, ASTM C31
ACI 318: 26.5, 26.12
CBC 1908.6, 1908.7, 1908.8
ACI 318: 26.5
CBC 1908.9
ACI 318: 26.5.3-26.5.5
l---+----+------------+---+---+---+-----1 L 11 CITY OF CARLSBAD I LJ
GRADING PLANS FOR:
APPROVED: JASON S. GELDERT
ENGINEERING MANAGER RCE 63912 EXPIRES 9/30/24 DATE
DATE INITIAL
ENGINEER OF WORK REVISION DESCRIPTION
DATE INITIAL DATE INITIAL
O'THER APPROVAL CITY APPROVAL
OWN BY: ---1 CHKD BY: __ _
RVWD BY: .
PROJECT NO. II DRAWING NO.I
DocuSign Envelope ID: 6864E9E6-E858-4902-9011-84C2E1CFCDEE
6/12/2023