Loading...
HomeMy WebLinkAboutSDP 2022-0002; 3060 STATE STREET; TRASH CAPTURE STORM WATER QUALITY MANAGEMENT PLAN; 2023-04-073060 STATE STREET SDP 2022-002 CDP 2022-003 TYLER G. LAWSON RCE NO: 80356 EXP. 12-31-2024 ______________________________________ TABLE OF CONTENTS Certification Page Project Vicinity Map FORM E-34 Storm Water Standard Questionnaire Site Information FORM E-36 Standard Project Requirement Checklist Summary of Trash Capture Structural BMPs Attachment 1: Backup for Trash Capture BMPs Attachment 1a: DMA Exhibit Attachment 1b: Tabular Summary of DMAs Attachment 1c: Trash Capture BMP Design Calculations Attachment 2: Trash Capture BMP Maintenance Thresholds and Actions Attachment 3: Single Sheet BMP (SSBMP) Exhibit 3060 STATE STREET TYLER G LAWSON, RCE NO: 80356, EXP 12-31-2024 PASCO, LARET, SUITER & ASSOCIATES SDP 2022-0002 APRIL 7, 2023 6 7 $ 1 ' $ 5 ' 3 5 2 - ( & 7 ¶ µ 6 7 $ 1 ' $ 5 ' 3 5 2 - ( & 7 ¶ Z L W K 3 5 , 2 5 , 7 < ' ( 9 ( / 2 3 0 ( 1 7 3 5 2 - ( & 7 ¶ 3 ' 3 SITE S T A T E S T VICINITY MAP SCALE: NTS N 5 R O O S E V E L T S T CARLS B A D V I L L A G E D R C A R L S B A D B L V D OAK A V E PINE A V E INSTRUCTIONS: To address post-development pollutants that may be generated from development projects, the city requires that new development and significant redevelopment priority projects incorporate Permanent Storm Water Best Management Practices (BMPs) into the project design per Carlsbad BMP Design Manual (BMP Manual). To view the BMP Manual, refer to the Engineering Standards (Volume 5). This questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision, discretionary permits and/or construction permits). The results of the questionnaire determine the level of storm water standards that must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to ‘STANDARD PROJECT’ requirements, ‘STANDARD PROJECT’ with TRASH CAPTURE REQUIREMENTS, or be subject to ‘PRIORITY DEVELOPMENT PROJECT’ (PDP) requirements. Your responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has responsibility for making the final assessment after submission of the development application. If staff determines that the questionnaire was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by you, this will result in the return of the development application as incomplete. In this case, please make the changes to the questionnaire and resubmit to the city. If you are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, please seek assistance from Land Development Engineering staff. A completed and signed questionnaire must be submitted with each development project application. Only one completed and signed questionnaire is required when multiple development applications for the same project are submitted concurrently. PROJECT INFORMATION PROJECT NAME: APN: ADDRESS: The project is (check one): New Development Redevelopment The total proposed disturbed area is: ft2 ( ) acres The total proposed newly created and/or replaced impervious area is: ft2 ( ) acres If your project is covered by an approved SWQMP as part of a larger development project, provide the project ID and the SWQMP # of the larger development project: Project ID SWQMP #: Then, go to Step 1 and follow the instructions. When completed, sign the form at the end and submit this with your application to the city. This Box for City Use Only City Concurrence: YES NO Date: Project ID: By: E-34 Page 1 of 4 REV 09/21 Development Services Land Development Engineering 1635 Faraday Avenue (760) 602-2750 www.carlsbadca.gov STORM WATER STANDARDS QUESTIONNAIRE E-34 203-297-05-003060 STATE STREET 3060 STATE STREET 0.146,004 X 0.052,320 X X X X X X X X X X X X X X X X X KIRK ALLISON CO-MANAGING MEMBER, JVK FMK VENTURE I LLC 3060 STATE STREET 3060 STATE STREETCARLSBAD, CA 92008 203-297-05-00 .14 6,004 X The existing site can be categorized into one (1) major drainage basin, with one (1) primary dischargelocation leaving the property. Drainage basin EX-1 consists of the entirety of the project site and primarilydrains from the east side of the property to the west, discharging to the State Street right-of-way by surfaceand sheet flow methods. Once in the State Street right-of-way, runoff leaving the site travels south towardsexisting storm water infrastructure in Oak Avenue. Surface flows entering the municipal stormwaterinfrastructure in Oak Avenue ultimately are conveyed south to outlet in the Agua Hedionda Lagoon prior toentering the Pacific Ocean. Convert two existing structures to restaurant and outdoor dining patio, including parking and landscapeimprovements as well as a storm drain system. X X Proposed project maintains existing point of discharge. Drainage patterns internal to the site will bechanged to match proposed grading. Site will collect on-site drainage into a storm drain network anddischarge into the existing gutter via sidewalk underdrain. 3060 STATE STREET X X X X X XX XX X X X X X X XX XX The trash capture BMP is located at each area drain located on site. The trash capture BMP is certified to capture all debris greater than 5-mm in size and is sized for a 1-hr1-hr storm event, minimum. The BMP selected complies with Certified Full Capture System Trash Treatment standards set forth by theCalifornia State Water Resources Control Board (Water Boards) and the California Stormwater QualityAssocation (CASQA). [Continued from previous page – This page is reserved for continuation of description of general strategy for trash capture BMP implementation at the site.] 1 TRITON TDAM BMP (TDAM12(3.5")) X X X Use this checklist to ensure the required information has been included on the DMA Exhibit: The DMA Exhibit must identify:  Site topography and impervious areas  Site drainage network and connections to drainage offsite  Proposed grading (if applicable)  Drainage management area (DMA) boundaries, DMA ID numbers, and DMA areas (square footage or acreage)  Trash Capture BMPs (identify location and type of BMP) 1.C) Trash Capture BMP Design Calculations Q = CIA *Rational Method Equation I = 0.471 in/hr *BMP design manual rainfall intensity for 1-hr 1-yr storm Total Area = 6,004 sf ➔ 0.138 Acres Impervious Area = 2,320 sf ➔ 0.053 Acres Pervious Area = 3,684 sf ➔ 0.085 Acres Cn, Weighted Runoff Coefficient - 0.25, Cn value for natural ground, Type B soils * Per San Diego Hydrology Design Manual (SDHDM) Section 3.1.2 - 0.9, C value for developed / impervious surface * Per SDHDM Section 3.1.2 Cn = 0.9 x 2,320 sf + 0.25 x 3,684 sf = 0.501 6,004 sf Basin PR-1 Total Area = 0.138 Acres Q1 = C I A =0.501 * 0.471 in/hr * 0.138 Acres = 0.033 cfs X RE: Trash Treatment Control Device Fact Sheet For REM Inc. Full Trash Capture TRITON PERF-FTC Device (Perforated Stainless Steel Trash Guard) December 21, 2021 Mr. Leo Cosentini California State Water Resources Control Board Division of Water Quality P.O. Box 100 Sacramento, CA. 95812 Dear Mr. Cosentini, REM Inc. would like to thank you for taking this opportunity to review our Updated Fact Sheet for the currently approved Full Trash Capture Device, our TRITON PERF-FTC. Throughout this application you will find the pertinent information requested from the Fact Sheet Update Requirements, presented in the requested layout. Currently, REM Inc. has the TRITON PERF-FTC Device as an approved FTC Device as well as the Trition BFTG-FTC Insert and the Triton CPS-FTC on the approved list of devices. Again, we thank you for taking this time to review our application, and if any additional information is required or needed, please feel free to contact us when needed. Charles Fleischmann Vice President Revel Environmental Manufacturing, Inc. REM Inc. 2 Section: 1 Cover Letter 1A: General Description The TRITON PERF-FTC can be used as a stand-alone filtration device for capturing trash and debris inside of storm drain catch basins. With its intended design, it can capture pollutants and debris as small as 5mm, meeting the requirement for Full Trash Capture Devices. It does this, while still maintaining excellent flow rates due to its 51% open area. The PERF-FTC device is intended to be installed in storm drain catch basins and is designed for lateral and surface flow capturing applications depending upon configuration. 1B: Device Owner Contact and location information Charles Fleischmann Vice President 960 Detroit Ave. Suite B Concord, CA. 94518 (925) 676-4736 Charlie@remfilters.com 1C: Website Information https://remfilters.com 1D: Manufacturing Location All REM TRITON products are manufactured and designed in the state of California. REM Inc. has specialized in providing storm drain filters/trash capture devices all over the country for 24+ years. *Address location listed above. 1E: Brief summary of field/testing results to demonstrate device functions The TRITON PERF-FTC was successfully tested in capturing debris that is 5mm or greater in size, in a number of test basins located in the greater San Francisco Bay Area and Southern California. Results and pictures from these tests can be found in Section 8. 1F: Brief summary of limitations, and operational, sizing, and maintenance considerations The TRITON PERF-FTC units are extremely adaptable and customizable in terms of mounting and attaching to the many different types of catch basin configurations in the field today. Due to the many different product applications REM has been able to offer, we have been very successful in filtering many catch basins that might otherwise be “passed up” on. Each of these devices can be adjusted to fit custom layouts/structures. The proper unit is determined in part by the outgoing pipe size, and then the structure size is taken into account. The approximate installation time takes between 10- 25 minutes, depending on the infrastructure layout. Maintenance on PERF-FTC devices typically involves an industrial vacuum truck when the units are about 50% loaded or as required. Maintenance should be performed at least 3 times per year or as needed. 3 This device is also able to house an absorbent media as well if ever required. No design modifications are needed, the media element is simply placed between the inner and outer layers of the stainless-steel support housings while maintaining its FTC requirement. 1G: Device installation locations REM Inc. has been installing PERF-FTC devices in multiple California locations as well as national sales across the U.S. as this has been an approved FTC device since 2018. Some installation areas of acknowledgement would be: City of Antioch: Dept. of Public Works City of Concord: Dept. of Public Works City of Hayward: Dept. of Public Works Please feel free to ask for a more detailed reference list. 1H: Certification Clause I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons that manage the system or those persons directly responsible for gathering the information, to the best of my knowledge and belief, the information submitted is true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. Charles Fleischmann Vice President REM Inc. 4 Section: 2 Table of Contents Page: Section: 3 Physical Description 3A: Trash Capture 5 3B: Peak Flows/Trash Volumes 5 3C: Hydraulic Capacity 5 3D: Comparison Table 8 3E: Design Drawings 11 3F: Alternative Configurations 17 3G: Internal Bypass 17 3H: Previously Trapped Trash 17 3I: Calibration Feature 17 3J: Photos 27 3K: Material Type 18 3L: Design Life 18 Section: 4 Installation Guidance 4A: Device installation procedures and considerations 19 4B: Description of installation limitations and non-standard installation procedures 25 4C: Methods for diagnosing and correcting installation errors 25 Section: 5 Operation and Maintenance Information 5A: Device inspection procedures and frequency considerations 25 5B: Maintenance frequency considerations due to capacity at various volumes 25 5C: Maintenance procedures 25 5D: Essential equipment and materials for proper maintenance 25 5E: Description of effects of deferred maintenance 26 5F: Repair procedures for device components 26 Section: 6 Vector Control Accessibility 6A: Date of device submittal to MVCAC 26 6B: Description that demonstrates vector control personnel accessibility 27 6C: Letter of Certification from MVCAC 33 Section: 7 Reliability Information 7A: Estimated design life of device 34 7B: Warranty information 34 7C: Customer support information 34 Section: 8 Field/Lab Testing Information and Analysis 8A: Device field testing and results 34 5 Section 3: Physical Description 3A: Trash Capture The TRITON-PERF-FTC device utilizes a Perforated Stainless Steel filter element, which has a 51% open area. This open area helps minimize occlusion and blinding while filtering at high volumes. The PERF is housed on the exterior of a stainless steel cartridge or as a stand alone filter element in a wide range of configurations depending upon the many different types and sizes of catch basin available today. 3B: Peak Flows/Trash Volumes PERF-FTC devices are primarily sized in accordance with the catch basins outgoing pipe diameter, inside wall dimensions or throat, below the grate. Selecting the correct size unit not only helps to ensure max flow/bypass rates are met, but also maximum trash capturing volume. The catch basin structure size is next used as a determining factor for identifying the proper size unit. For example: a 2’ X 3’ catch basin could utilize a model TR2436-PERF-FTC which allows enough spacing from the walls for incoming water flows to be fully captured. 3C: Hydraulic Capacity Section 1) Standard size models shown: Inserts: Model: Housing Body Width: Cartridge Height: Cartridge Max Treatment Rate: (Empty) Bypass Flow: TR1818 TR24RDTR2436 17.5" X 17.5" 8" 23.5" Dia. 12" TR14-CART(12) 34.5" X 23.5" 8" 4.42 (CFS) 13.15 (CFS) 6.64 (CFS) 13.15 (CFS) 3.18 (CFS) 5.14 (CFS) TR14-CART(16) 8.85 (CFS) 13.15 (CFS) TR36RD 16" Cartridge Diameter: 14" Dia.14" Dia.10" Dia.14" Dia. TR14-CART(8)TR14-CART(8) Treatment Rate at 50% capacity: 2.21 (CFS) 3.32 (CFS) 1.59 (CFS) 4.42 (CFS) Treatment Rate at 75% capacity: 1.11 (CFS) 1.66 (CFS) .79 (CFS) 2.21 (CFS) TR10-CART(8) TR24SR 23.5" X 23.5" 12" TR14-CART(12) 6.64 (CFS) 13.15 (CFS) 14" Dia. 3.32 (CFS) 1.66 (CFS) 35" Dia. 6 Top Hat: Model: Width: Cartridge Height: Cartridge: Max Treatment Rate: (Empty) Bypass Flow: TR1818-TH TR24RD-THTR2436-TH 17.5" X 17.5" 8" 23.5" Dia. 12" TR14CART(12) 23.5" X 34.5" 8" 4.42 (CFS) 13.15 (CFS) 6.64 (CFS) 13.15 (CFS) 3.18 (CFS) 5.14 (CFS) Cartridge Diameter:14"14"10" TR14-CART(8)TR14CART(8) Treatment Rate at 50% capacity: 2.21 (CFS) 3.32 (CFS) 1.59 (CFS) Treatment Rate at 75% capacity: 1.11 (CFS) 1.66 (CFS) .79 (CFS) TR10CART(8) TR36RD-TH 35" Dia. 16" TR14CART(16) 8.85 (CFS) 13.15 (CFS) 14" 4.42 (CFS) 2.21 (CFS) Curb Inlet: Model: Width: Height: Max Treatment Rate: (Empty) Bypass Flow: TRC2.0 TRC7.0TRC3.5 9" 12.5" 9" 12.5" 9" 12.5" 12.67 (CFS) 28.42 (CFS) 3.62 (CFS) 8.35 (CFS) Length:7'3.5'2' Treatment Rate at 50% capacity: 6.33 (CFS) 1.81 (CFS) Treatment Rate at 75% capacity: 3.16 (CFS) .91 (CFS) TRC14.0 9" 12.5" 25.31 (CFS) 56.35 (CFS) 14' 12.65 (CFS) 6.32 (CFS) 6.33 (CFS) 14.24 (CFS) 3.16 (CFS) 1.58 (CFS) 7 Area Drain: Model: Diameter: Height: Cartridge: Max Treatment Rate: (Empty) Bypass Flow: ADF-7 ADF-14ADF-10 7" Dia. 8" 14" Dia. 16" TR14CART(16) 10" Dia. 8" 3.18 (CFS) 5.14 (CFS) 8.85 (CFS) 13.15 (CFS) 2.22 (CFS) 1.61 (CFS) Bypass:10" Dia.6" Dia.3" Dia. TR14-CART(8)TR10CART(8) Treatment Rate at 50% capacity: 1.59 (CFS) 4.42 (CFS) 1.1 (CFS) Treatment Rate at 75% capacity: .79 (CFS) 2.21 (CFS) .55 (CFS) TR7CART(8) ADF-24 24" Dia. 16" TR24CART(16) 15.26 (CFS) 51.29 (CFS) 20" Dia. 7.63 (CFS) 3.81 (CFS) TDAM: Model: Width: Height: Trench Width: Max Treatment Rate: (Empty) Bypass Flow: TT2 TDAM8(10)TDAM5(5) 4" 4" 8" 10" 8" 5" 5" .17 (CFS) .55 (CFS) .52 (CFS) .88 (CFS) .025 (CFS) .44 (CFS) Bypass:3" X 8"3" X 5"3" X 4" TR14-CART(8)5" Treatment Rate at 50% capacity: .08 (CFS) .26 (CFS) .013 (CFS) Treatment Rate at 75% capacity: .04 (CFS) .13 (CFS) .006 (CFS) 4" TDAM12(5) 12" 5" 12" .40 (CFS) 1.33 (CFS) 3" X 12" .20 (CFS) .11 (CFS) 8 Section 2) To determine the treatment rates, a commonly used equation was calculated. This is similar to the method used by the County of Los Angeles Dept. of Public Works in a 2006 report on Full Capture Screen and Bypass Requirements. An example of the equation is below: C A 2gh Q MTFR =SF d Calculation for the model TR24SR-PERF-FTC Device: 0.60 * 2.08sf 2 * 32.2ft s 2 * .66ftQMTFR=2 This equals: 3.32 CFS for the maximum treatment flow rate, while utilizing a safety factor of 2. Section 3) N/A – No alternative configurations effect the hydraulic capacities of the devices. 3D: Comparison Table *For standard sized models. More sizes and custom configurations are available. Inserts: Model: Housing Body Width: Cartridge Height: Cartridge Max Treatment Rate: (Empty) TR1818 TR24RDTR2436 17.5" X 17.5" 8" 23.5" Dia. 12" TR14-CART(12) 34.5" X 23.5" 8" 4.42 (CFS) 6.64 (CFS) 3.18 (CFS) TR14-CART(16) 8.85 (CFS) TR36RD 16" Cartridge Diameter:14" Dia.14" Dia.10"14" Dia. TR14-CART(8)TR14-CART(8) Maximum Trash Capture Volume: (gallons) 22.7 (Gallons) 14.5 (Gallons) 7.8 (Gallons) 59.8 (Gallons) TR10-CART(8) TR24SR 23.5" X 23.5" 12" TR14-CART(12) 6.64 (CFS) 14" Dia. 14.5 (Gallons) 35" Dia. 9 Top Hat: Model: Width: Cartridge Height: Cartridge: Max Treatment Rate: (Empty) TR1818-TH TR24RD-THTR2436-TH 17.5" X 17.5" 8" 23.5" Dia. 12" TR14CART(12) 23.5" X 34.5" 8" 4.42 (CFS) 6.64 (CFS) 3.18 (CFS) Cartridge Diameter:14"14"10" TR14-CART(8)TR14CART(8) Maximum Trash Capture Volume: (gallons) 24.5 Gallons 15.51 Gallons 8.51 Gallons TR10CART(8) TR36RD-TH 35" Dia. 16" TR14CART(16) 8.85 (CFS) 14" 59.84 Gallons Curb Inlet: Model: Width: Height: Max Treatment Rate: (Empty) TRC2.0 TRC7.0TRC3.5 9" 12.5" 9" 12.5" 9" 12.5" 3.88 (CFS) .82 (CFS) Length:7'3.5'2' Maximum Trash Capture Capacity: (Gallons) 40.9 Gallons 11.69 Gallons TRC14.0 9" 12.5" 7.74 (CFS) 14' 81.8 Gallons 1.93 (CFS) 20.45 Gallons 10 Area Drain: Model: Diameter: Height: Cartridge: Max Treatment Rate: (Empty) ADF-7 ADF-14ADF-10 7" Dia. 8" 14" Dia. 16" TR14CART(16) 10" Dia. 8" 3.18 (CFS) 8.85 (CFS) 2.22 (CFS) Bypass:10" Dia.6" Dia.3" Dia. TR14-CART(8)TR10CART(8) Maximum Trash Capture Capacity: (Gallons) 3.41 Gallons 13.33 Gallons 1.67 Gallons TR7CART(8) ADF-24 24" Dia. 16" TR24CART(16) 15.26 (CFS) 20" Dia. 39.17 Gallons TDAM: Model: Width: Height: Trench Width: Max Treatment Rate: (Empty) TT2 TDAM8(10)TDAM5(5) 4" 4" 8" 10" 8" 5" 5" .17 (CFS) .52 (CFS) .025 (CFS) Bypass:3" X 8"3" X 5"3" X 4" TR14-CART(8)5" Maximum Trash Capture Capacity: (Gallons) 5.19 Gallons 16.62 Gallons 3.32 Gallons 4" TDAM12(5) 12" 5" 12" .40 (CFS) 3" X 12" 12.47 Gallons 11 3E: Design Drawings REM TRITON PERF - FTC • Cartridge support housing uses Type 304 13ga., stainless steel , with 2" welded square opening. • Perforated stainless steel is configured with a 4.8mm openings, having 51% Open Area for excellent flow rates comparative to size. • The Stainless Steel Perforation is designed to capture 100% of trash and debris at 5 mm or greater in size.• Flow rate based on .10 cfs, per square foot. • Made in the USA. • Maintenance information and replacement REM Media Packs (If used) are available upon request by contacting REM at sales@remfilters.com or (888) 526-4736. A side view of the Type 304 13ga. Stainless Steel welded 2" square housing with 22ga Type 304 Stainless Steel Perforation. Booted Stainless Area Drain Filter. Notes: TDAM12-PERF General Flow Rates Per Square Foot 1' X 1' Square Foot = .11 Cfs. 2' X 2' Square Foot = .42 Cfs. 3' X 3' Square Foot = .95 Cfs. Product Overview: REM s PERF-FTC Filter Screen utilizes 22ga., Type 304 Stainless Steel Perforation. Perforated stainless steel is configured with a 4.8mm openings, having 51% Open Area for excellent flow rates comparative to size. The Stainless Steel Perforation is designed to capture 100% of trash and debris at 5 mm or greater in size. PERF-FTC is housed in stainless steel cartridges in a wide range of configurations, depending upon the many different types and sizes of catch basin available today. PERF-FTC may be utilized in both new construction or retrofitted in existing catch basin filters. They are sized to spec or modified in the field for drains with unusual dimensions and unique frame and grates. Filter Cartridges may be easily removed when servicing. Different media strategies can be combined with PERF Screen Design to optimized capturing for specific pollutant of concerns. TR2436-TH-PERF Top Hat Filter.MiniGT6-PERF ADF-14-PERF TR2436-PERF Inlet Filter. 12 REM TRITON PERF-FTC INSERT Cartridge Standard size dimensions Model: Insert (Cartridge Size)Diameter:Height:Bypass Diameter: Filtered Flow Rate: Bypass Flow Rate: TR14(12) Cartridge TR14(16) Cartridge 14"12" 14"16" 6.64 (CFS) 8.85 (CFS) 10" 10" 13.15 (CFS) 13.15 (CFS) 10" Dia. Inner and Outer Support Bars: Type 304 SS 13 GA. Horizontal and vertical bars. 2" X 2" spacing. 90% Recycled ABS Top and bottom cap. Bottom cap has 1" wide cut outs to prevent standing water. Bypass Overflow Perforated Screen: Type 304 SS 16 GA. with 4.8mm openings. 51% Open Area 14" Dia. 12" or 16" Cartridge Height Unit can be sized to any 2" increment in height. (2"-32") • Units are constructed using a 13 GA. Stainless Steel inner and outer housing support for added structural integrity. • Perforated Stainless Steel is configured with a 51% Open Area for excellent flow rates. • Custom sizes and configurations are available. • Multiple units can be mounted vertically to increase capture capacity. • PERF Cartridge unit is capable of housing an absorbent media if ever required, with no retrofitting or modifications needed. Notes: Locking Ring Cartridge locks into place with a simple ¼ turn to the right. To remove, turn to the left. TRITON (FULL TRASH CAPTURE INSERT) TOP HAT SERIES CATCH BASIN FLOW FLOW CAPTURED TRASH & DEBRIS FILTERED FLOW OVERFLOW BYPASS TRITON PERF-FTC INSERT Top Hat FILTER SERIES By REM Inc. (888.526.4736) REMFILTERS.COM Curb Opening Exit Pipe 13 REM TRITON INSERT – PERF - FTC Notes: Product Overview: Standard Size Dimensions (Not all model and sizes are listed here) FLOW TRITON INSERT INLET FILTER CATCH BASIN FLOW FLOW FILTERED FLOW CAPTURED TRASH & DEBRIS REM s TRITON – INSERT-PERF Filters are multipurpose catch basin filters designed to capture sediment, trash, debris, suspended solids, and other storm water pollutants. They may be utilized in new construction or retrofitted in existing catch basin structures. They are sized to spec or modified in the field for drains with unusual dimensions and unique frame and grates. The TRITON Perforated Stainless (PERF) Screen that is designed to capture debris, trash and sediment while sustaining very high treatment rates as a Full Trash Capture System. Capturing 100% of particles at 5mm or greater in size. Filter Cartridges may be easily removed when servicing. Media strategy may be optimized for specific pollutant concerns. • Filter bodies are constructed using 100% recycled High Molecular Weight Polyethylene Plastic (HMWPE) with U.V. inhibitors. • Filter cartridge housings are constructed utilizing Type 304 13ga. Stainless Steel, with 2" welded square openings. • Removable cartridge tops and bottoms are constructed utilizing over 90% recycled ABS Plastic. • Filter Screen utilizes 22ga., Type 304 Stainless Steel Perforation.• Perforated Stainless Steel is configured with a 4.8mm openings, having 51% Open Area for excellent flow rates comparative to its size. • REM TRITON filter cartridges can be removed for ease of cleaning and maintenance.• Filter designs include a high flow overflow bypass to eliminate pooling or flooding during heavy rain events. • Maintenance information and replacement REM Media Packs are available upon request by contacting REM at sales@remfilters.com or (888) 526-4736. • Made in the USA. Side View MADE INUSA Grate Removable Stainless Steel Cartridge Housing Filter Body Catch Basin Removable Top Cap TR2424-PERF Installed Round Catch Basin TR2424 Removing Cartridge Model: Width: Cartridge Height: Cartridge Max Treatment Rate: Bypass Flow: TR1818-PERF TR24RD-PERFTR2436-PERF 17.5" X 17.5" 8" TR10-CART(8) 23.5"Dia. 12" TR14-CART(12) 34.5" X 23.5" 8" 4.42 (CFS) 13.15 (CFS) 6.64 (CFS) 13.15 (CFS) 3.18 (CFS) 5.14 (CFS) 35" TR14-CART(16) 8.85 (CFS) 13.15 (CFS) TR36RD-PERF 16" Cartridge Diameter:14" Dia.14" Dia.10" Dia.14" Dia. TR14-CART(8)TR14-CART(8) Stainless Steel Filter Screen TR24RD-PERF Installed 14 REM TRITON TOP HAT – PERF - FTC Notes: Product Overview: Standard Size Dimensions (Not all model and sizes are listed here) REM s TRITON – Top Hat Filters were designed to provide a highly adaptable solution that allows the flexibility to maximize the filter treatment flow rate and pollutant debris capturing capacity. This multipurpose design allows the system to be installed in many different catch basin configurations. Top Hat Filters are designed to capture sediment, trash, debris, suspended solids, and other storm water pollutants. They may be utilized in new construction or retrofitted in existing catch basin structures. They are sized to spec or modified in the field for drains with unusual dimensions and unique frame and grates. The TRITON Perforated Stainless (PERF) Screen that is designed to capture debris, trash and sediment while sustaining very high treatment rates as a Full Trash Capture System. Capturing 100% of particles at 5mm or greater in size. Filter Cartridges may be easily removed when servicing. Media strategy may be optimized for specific pollutant concerns. • Base plates are constructed using High Density Polyethylene Plastic (HDPE).• Filter cartridge housings are constructed utilizing Type 304 13ga. Stainless Steel, with 2" welded square openings. • Removable cartridge tops and bottoms are constructed utilizing over 90% recycled ABS Plastic. • Filter Screen utilizes 22ga., Type 304 Stainless Steel Perforation.• Perforated Stainless Steel is configured with a 4.8mm openings, having 51% Open Area for excellent flow rates comparative to its size. • REM TRITON filter cartridges can be removable for ease of cleaning and maintenance. • Filter designs include a high flow overflow bypass to eliminate pooling or flooding during heavy rain events. • Maintenance information and replacement REM Media Packs are available upon request by contacting REM at sales@remfilters.com or (888) 526-4736. • Made in the USA. MADE INUSA Grate Removable Stainless Steel Cartridge Housing & Screen Filter Base Plate Catch Basin TRITON TOP HAT FILTER CATCH BASIN FLOW FLOW CAPTURED TRASH & DEBRIS FILTERED FLOW OVERFLOW BYPASS Side View Allows for Optional Downspout Filtering Model: TR3636-TH-PERF Installed Side View Round Catch Basin Top Hat Model: Width: Cartridge Height: Cartridge Max Treatment Rate: Bypass Flow: TR1818-TH- PERF TR24RD-TH- PERF TR2436-TH- PERF 17.5" X 17.5" 8" TR10-CART(8) 23.5"Dia. 12" TR14-CART(12) 34.5" X 23.5" 8" 4.42 (CFS) 13.15 (CFS) 6.64 (CFS) 13.15 (CFS) 3.18 (CFS) 5.14 (CFS) 35" TR14-CART(16) 8.85 (CFS) 13.15 (CFS) TR36RD-TH- PERF 16" Cartridge Diameter:14" Dia.14" Dia.10" Dia.14" Dia. TR14-CART(8)TR14-CART(8) 15 OVERFLOW BYPASS FILTERED FLOW TRITON CURB INLET FILTER Curb Opening To Street Inside walls of catch basin REM TRITON CURB INLET – PERF - FTC Notes: Model: Width/ Height: Length: Max Treatment Rate: Bypass Flow: TRC2.5-PERF TRC3.5-PERF TRC7.0-PERF 12"/12" 2.5' 12"/12" 3.5' 12"/12" 7' 12.67 (CFS) *28.42 (CFS) 6.33 (CFS) *14.24 (CFS) 3.62 (CFS) *8.35 (CFS) 12"/12" 25.31 (CFS) *56.35 (CFS) TR14.0-PERF 14' Product Overview: Standard Size Dimensions (Not all model and sizes are listed here) • Filter bodies are constructed using 100% recycled High Impact Polystyrene plastic (HIPS) with UV inhibitors and rubber additives. • Filter screen utilizes 22ga, Type 304 Stainless Steel perforation. • Perforated Stainless Steel is configured with a 4.8mm openings, having a 51% Open Area for excellent flow rates comparative to its size. • Optional Stainless Steel Cartridge housings are capable of housing an absorbent media if ever required, with no retrofitting or modifications needed.• REM TRITON filter cartridges are removable for ease of cleaning and maintenance. • Filter designs include a high flow overflow bypass to eliminate pooling or flooding during heavy rain events. • Maintenance information and replacement REM Media Packs are available upon request by contacting REM at sales@remfilters.com or (888) 526-4736.• Made in the USA. MADE INUSA REM designed the TRITON -TRC (Curb Inlet) Filter Series to provide a highly adaptable solution that allows the flexibility to maximize the filter treatment flow rates and pollutant capturing capacity. TRITON - TRC Filters may be utilized in new construction or retrofitted in existing catch basin structures. They are sized to spec and scalable for all different lengths of curb inlet catch basins. The TRITON TRC - PERF – FTC Series uses Perforated Stainless Steel (PERF) Screen that is designed to capture debris, trash and sediment while sustaining very high treatment rates as a Full Trash Capture System. Capturing 100% of particles at 5mm or greater in size. Media strategy may be optimized for specific pollutant concerns. TRITON CURB INLET Curb Storm Event Regular Treated Flow Overflow Bypass Street *Note: Potential overflow bypass will be equal to or greater then the curb opening in the street. Device has a greater area for bypass which is larger than the curb opening. FILTERED FLOW OVERFLOW BYPASS Front View Model TRC3.0 16 REM TRITON TDAM - PERF - FTC Notes:Model: Width: Height: Trench Width Max Treatment Rate: TT2-PERF TDAM5(5)- PERF TDAM8(10)- PERF 4" 4" 4" 5" 5" 5" 8" 10" 8" .52 (CFS) .17 (CFS) .02 (CFS) 12" 12" .40 (CFS) TDAM12(5)- PERF 5" Product Overview: Standard Size Dimensions (Not all model and sizes are listed here) • TDAM housings are constructed utilizing Type 304 16ga. Stainless Steel, with 1" and 2" welded square openings. • Removable cartridge tops and bottoms are constructed utilizing over 90% recycled ABS Plastic or fiberglass. • Filter screen utilizes 22ga, Type 304 Stainless Steel perforation. • Perforated Stainless Steel is configured with a 4.8mm openings, having a 51% Open Area for excellent flow rates comparative to its size. • REM TRITON filter cartridges can be removable for ease of cleaning and maintenance.• Filter designs include a high flow overflow bypass to eliminate pooling or flooding during heavy rain events. • Optional Stainless Steel Cartridge housings are capable of housing an absorbent media if ever required, with no retrofitting or modifications needed. • Maintenance information and replacement REM Media Packs are available upon request by contacting REM at sales@remfilters.com or (888) 526-4736.• Made in the USA. REM designed the TRITON -TDAM Filter Series to provide a highly adaptable solution that allows the flexibility to maximize the filter treatment flow rates and pollutant capturing capacity in trench drain and shallow type drains applications. The TRITON TDAM - PERF - FTC Series uses Perforated Stainless Steel (PERF) Screen that is designed to capture debris, trash and sediment while sustaining very high treatment rates as a Full Trash Capture System. Capturing 100% of particles at 5mm or greater in size. TRITON -TDAM Filters can be sized to fit most industry standard trench drains, parkway drains, shallow structures, catch basins, etc. They are sized to spec and scalable for all different lengths and applications. Media strategy may also be optimized for specific pollutant concerns. TRITON TDAM s TYPICAL TRENCH DRAIN Stainless Steel Screen Mounting Tabs TDAM Stainless Steel Housing Removable Cap TDAM15 (5.5) installed TDAM (TT2)-PERF for rounded bottom trench drains. Rounded bottom trench drains. (Heights: 3.5", 5.5", 10" & Custom) Width: 1.5" (Lengths: 4" up to 10', + custom sizes) TDAM12 (5.5") - PERF Note: Potential overflow bypass will depend upon the dept of each trench drain. Overflow Bypass Flow Est. Bypass .88 (CFS) .55 (CFS) .44 (CFS) 1.33 (CFS) 17 3F: Alternative Configurations There are no alternative configurations. 3G: Internal Bypass All of the TRITON PERF-FTC Filters have built-in overflow bypass systems, this is breached only when the device has become inundated with an excessive amount of debris and the device has reached its debris holding capacity, or during a large storm event that exceeds the hydraulic capacity of the device. Essentially the device would need to be at 100% capacity for the bypass level to be reached. It is ultimately the responsibility of the engineer and/or deciding party to determine that the correct unit size is appropriate for the selected basin and corresponding flow capacity. 3H: Previously Trapped Trash With the design of the TRITON PERF-FTC, trash should only be re-introduced in a case where the device has reached 100% capacity during normal operating conditions. REM recommends that the devices are cleaned and maintained before or at 50% capacity to ensure proper functionality. 3I: Calibration Feature These devices do not contain any adjustable calibration features. 3J: Photos TR2436 TR24SR TR3636-TH 18 3K: Material Type The design and construction of the TRITON PERF-FTC is comprised of the following materials: Type 304 stainless steel, 90% recycled content ABS plastic cap with UV Inhibitors or a fiberglass cap. The main housing and structural support body is made up of an inner and outer wall of 13 GA. Type 304 stainless steel welded mesh with 2” X 2” square openings. The filter housings are comprised of 100% recycled HMWPE (High Molecular Weight Polyethylene) and the PERF, which is a type 304 Stainless-Steel, it is 22 GA. with 4.8mm openings which creates a total open area of 51%. 3L: Design Life Under normal operations and with the impact of large storm events, the TRITON PERF-FTC has an estimated lifespan of 20+ years. Naturally occurring elements and mineral saturation do not have a resounding effect on either the stainless steel, HMWPE, fiberglass or the ABS used in construction. This section intentionally left blank 19 Section 4: Installation Guidance 4A: Device installation procedures and considerations STAINLESS STEEL REMOVABLE CARTRIDGE HOUSING FILTER BODY REPLACABLE MEDIA-PACKS TOP CAP BOTTOM CAP MADE INUSA For units that require to be mounted below the ledge please refer to the following instructions: Step #1) If the Insert Filter has not been pre-cut, you will need to measure the Inside dimensions of the catch basin walls to determine the flange size you will need. It should be ½ smaller than your I.D. For example, if the Inside Dimensions are 24"X24" you will need to cut your flanges to be 23.5"X23.5". For round catch basins, measure the inside dimension then cut the filter flange ½ Dia., less, then the ID, then apply bulb gasket. Example: 24" Dia. ID, Cut Insert flange to 23.5" Dia. INSTALLATION INSTRUCTIONS FOR THE TRITON MODEL: INSERT – PERF - FTC (Designed for Square and Round catch basins and other applications) Step 1)If your TRITON Insert Filter has been pre-cut for you, simply remove the grate, clean any debris that is found on the ledge that the grate rests on. Step 2) Place Filter Cartridge inside of unit, and line up with stainless steel screws on the bottom of the cartridge. Press down and twist 1/6th of a turn to lock cartridge in place, making sure filter is snug enough to prevent water from bypassing. Insert filter housing into catch basin as to where the flanges are resting on the grate & frame ledges. Place grate back on catch basin. Step 3)If you received your unit un-cut, trim the flanges of the filter to be ½ smaller than the frame that surrounds the grate on the two support sides. Trim the other two sides that will not be supported to be ½ smaller than the clear frame opening, attach the supplied bulb gasket to the non-supported sides and set the Insert Filter into place. Place grate back on catch basin. Note: Round units will be trimmed to ¼ smaller diameter than the size of the grate and will not use an attachable bulb gasket. Support Bracket mounting Determine where the support brackets will need to be placed in the catch basin for best support. To help you do this, place the filter into the catch basin and mark were the center of the support should be. Support brackets should be evenly positioned for filter support. The top of the Insert Filter should rest 2" to 4" below the bottom of the grate. Using anchor bolts, attach the corner brackets to the inside walls of the catch basin using a hammer drill with ¼ bit. Make sure anchor bolts are as flush as possible to inside wall. Once the bracket are in place, place Insert Filter into catch basin and place grate back on catch basin. TOOLS REQUIRED: 1) Skil saw. 2) Snips. 3) Hammer Drill, with ¼ masonry drill bit. 4) Hammer. 5) ¼ X 2" or 3" Concrete Anchors. i.e. (Red Head) 6) 7/16" Socket Drive. Filter Flange (Supported on the same flange the grate rest on)TRITON DROP INLET FILTER REMOVABLE CARTRIDGE CATCH BASIN Overflow Port Anchors Bolts Support Bracket Support Bracket 20 INSTALLATION INSTRUCTIONS FOR THE TRITON MODEL: TOP HAT (ROUND) – PERF - FTC (Designed for Square and Round catch basins and other applications) TOOLS REQUIRED: 1) Skil saw. 2) Snips. 3) Hammer Drill, with ¼ masonry drill bit. 4) Hammer. 5) ¼ X 2" or 3" Concrete Anchors. i.e. (Red Head) 6) 7/16" Socket Drive. MADE INUSA Step 1) Filter base plate flanges may need to be trimmed to fit into the throat of the catch basin. For example if the ID or inside throat of the catch basin is 24"Dia., you will want to trim the flanges down to 23.5"Dia. (Taking just a ½ off the dia.) You will then attach the bulb gasket to the outer edge of base plate. This bulb gasket will help seal any gap between the base plate and th e inside wall of the catch basin. The gasket is designed to give the base plate a snug fit when installed. Some base plates may be pre-trimmed and ready for installation. Step 2) Depending upon the filters cartridge configuration the support brackets will vary with the height of each cartridge height. For the 8" Tall Cartridges, the brackets should be mounted 10" or more below the grate seat. For 16" Tall Cartridges, mounting brackets should be at least 19" or more below the grate seat (See attached Side View illustration below). Step 3) Attach support brackets (Corner and slotted angle, if applicable) to the catch basin throat wall on four to eight sides equally spaced using anchor bolts. Attach slotted angle crossbars for larger catch basins (see Top View illustration below). Step 4) Install filter base plate first without cartridge attached. Once a tight fit along the inside diameter of the catch basin is obtained, attach the cartridge and replace grate. Note: For catch basins that may have a tighter throat due to the frame and grate or other obstruction near the top, the filter base plate may come in two sections that can be un-assembled, which will allow the base plate to be re-assembled below this area. These parts will come assembled, so that you know how they should look like when installed. If you need further assistance please call us direct at (888) 526-4736 or email us your questions at: Sales@remfilters.com Side View Of Top Hat Filter Filter Base Plate Side View Inside wall of catch basin Anchor bolts into inside of catch basin For (8") Tall Cartridges 10" or more below grate seat. For (16") Tall Cartridges 19" or more below grate seat. Grate Seat 10" 19" Mounting Brackets Top View Of mounting brackets OverflowBypass Support Brackets Anchor Bolts Support Brackets Base Plate Filter Cartridge Filter Cartridge Support Brackets GRATE 21 INSTALLATION INSTRUCTIONS FOR THE TRITON MODEL: TOP HAT (SQAURE) – PERF - FTC (Designed for Square and Round catch basins and other applications) TOOLS REQUIRED: 1) Skil saw. 2) Snips. 3) Hammer Drill, with ¼ masonry drill bit. 4) Hammer. 5) ¼ X 2" or 3" Concrete Anchors. i.e. (Red Head) 6) 7/16" Socket Drive. MADE INUSA Step 1) Filter base plate flanges may need to be trimmed to fit into the throat of the catch basin. For example if the ID or inside throat of the catch basin is 24" X 24", you will want to trim the flanges down to 23" X 23". You will then attach the bulb ga sket to the outer edge of base plate. This bulb gasket will help seal any gap between the base plate and the inside wall of the catch basin. The gasket is designed to give the base plate a snug fit when installed. Some base plates may be pre-trimmed and ready for installation. Step 2) Depending upon the filters cartridge configuration the support brackets will vary with the height of each cartridge height. For the 8" Tall Cartridges, the brackets should be mounted 10" or more below the grate seat. For 16" Tall Cartridges, mounting brackets should be at least 19" or more below the grate seat (See attached Side View illustration below). Step 3) Attach support brackets (Corner and slotted angle, if applicable) to the catch basin throat wall on four to eight sides equally spaced using anchor bolts. Attach slotted angle crossbars for larger catch basins (see Top View illustration below). Step 4) Install filter base plate first without cartridge attached. Once a tight fit along the inside diameter of the catch basin is obtained, attach the cartridge and replace grate. Note: For catch basins that may have a tighter throat due to the frame and grate or other obstruction near the top, the filter base plate may come in two sections that can be un-assembled, which will allow the base plate to be re-assembled below this area. These parts will come assembled, so that you know how they should look like when installed. If you need further assistance please call us direct at (888) 526-4736 or email us your questions at: Sales@remfilters.com Side View Of Top Hat Filter Filter Cartridge Filter Base Plate Support Brackets Top View Of mounting brackets Overflo w Port Center Support Bars Concrete Anchor Bolts Position of overflow bypassAnd Cartridge Base Support Brackets GRATE Inside wall of catch basin Anchor bolts into inside of catch basin For (8") Tall Cartridges 10" or more below grate seat. For (16") Tall Cartridges 19" or more below grate seat. Grate Seat 10" 19" Support Bracket 22 INSTALLATION INSTRUCTIONS FOR THE TRITON MODEL: CURB INLET – PERF - FTC MADE INUSA Step 1) While inside of the curb inlet catch basin, starting from the left side wall to the right side wall of the curb inlet catch (while facing the street) Place Curb Inlet Filter 2" to 3" below the start of the inside vertical wall. Mark the height on the wall. Note: If the curb inlet is larger than 3.5', you will be using additional section of filter. Joint Couplings will also be supplied to connect the section together (See Figure #3) Each filter section should come with two Cradle Brackets. Step 2) Determine where the Cradle Brackets are to be placed horizontally along the inside wall. The bracket should be placed in between the windows of the curb inlet filter. For a 2' Curb Inlet section with only one window, the brackets will go on the two ends. (They should not block any of the open areas of the windows. Having the cradle brackets in position against the wall, mark the location using the existing mounting holes in the bracket as a template. These are where the holes are to be drilled to mount the brackets. Drill two holes per bracket using ¼ masonry drill bits to install the concrete anchors. Secure cradle brackets to wall using 7/16" socket driver. Step 3) Once the two cradle brackets are installed, place the Curb Inlet Filter into the cradle brackets. Attach zip ties around cradle brackets and filter. Step 4) When adding adjacent sections, duplicate steps #1, #2, and #3, installing from left to right making sure all sections are at the same height. After installing the first two sections, place the black ABS Joint Coupling (Provided) into both adjoining filter ends, then lock coupling into place by using set screws (pre-drilled into coupling) If you need further assistance please call us direct at (888) 526-4736 or email us your questions at: Sales@remfilters.com Place Cradle Bracket 2" to 3" below the start of the inside vertical wall. Cradle Bracket (¼ X 3" wide) Galv. Steel Cradle Bracket (¼ Thick X 3" wide) 2" to 3" Street level Inside wall of curb inlet View facing curb Inlet and street Cradle Bracket Placement (L) Windows Street Curb Figure #1 Zip-Tie Placement Figure #2 Figure #3 Joint Cplg Joint Cplg 3.5'3.5' Bracket Cradle ¼ X 2.25" long Anchor Bolts 7.0' Curb Inlet Example 23 INSTALLATION INSTRUCTIONS FOR THE TRITON MODEL: AREA DRAINS – PERF - FTC Note: Area Drain Filters have been designed to be installed in a variety of different applications. Most common are exit pipes that exit vertically through a catch basin or other receiving vessel. There are two ways of securing Area Drain Filter into position. Option A) If filter has been designed using a boot to connect to catch basin, it is simply pushed into place like a compression fitting. Before doing so, clean the bottom of the catch basin where the filter will be placed. Note: confirmation of exit pipe size is necessary so that the Area Drain Filter is fitted with the correct boot size. Option B) If filter has been designed using a tab mounting system, place Area Drain Filter directly over exit pipe and center. Make sure to clean the bottom of the catch basin where the filter will be placed first. Using a hammer drill with ¼ masonry drill bit, drill through existing mounting plates pre-drilled holes that are attached to both the bottom and sides of the Area Drain Filter. Hammer in anchor bolt (Red Head s), place washer over plate, then tighten down with nut using a 7/16" socket drive. If you need further assistance please call us direct at (888) 526-4736 or email us your questions at: Sales@remfilters.com Figure #1 Figure #2 Boot Connector TOOLS REQUIRED: 1) Hammer Drill, with ¼ masonry drill bit. 2) Hammer. 3) ¼ X 2" or 3" Concrete Anchors. i.e. (Red Head) 4) 7/16" Socket Drive. Figure #3 CATCH BASIN TRITON AREA DRAIN FILTER (ADF)FLOW FLOW BOOT CONNECTOR OPTION FLOOR MOUNTING TAB OPTION STAINLESS STEEL REMOVABLE CARTRIDGE HOUSING OR DRAIN DOME GRATE OR STANDARD FLAT GRATE Side View Cut - Away Roof Surface AREA DRAIN BODY (EXISTING AREA FOR CAPTURING DEBRIS) EXIT PIPE SELF TIGHTENING BOOT OVERFLOW PORT BFTG FILTER MEDIA BOOT CONNECTOR STAINLESS STEEL HOUSING MADE INUSA FLOOR MOUNTING TABS Floor Mounting Tabs 24 INSTALLATION INSTRUCTIONS FOR THE TRITON MODEL: TDAM – PERF - FTC MADE INUSA Step 1) TDAM s are to be placed every 3' to 4' from one another unless otherwise specified, (See Figure #3). (TDAM s next to exiting pipe of trench drain should be placed 4" to 6" from the exit), (See Figure #2) Some trenches may have exit pipes at both ends or in the middle of the trench. Use the same instructions for each. For middle exiting pipes, place one TDAM on each side of exit pipe, 4" to 6" from exit pipe, (See Figure #2). Step 2) After deciding placement of TDAM s, Clean any sediment or debris from location. Slide TDAM into trench drain, until it reaches the bottom of trench floor. Make sure to place additional gasket in area s where there are gaps or where water may try to bypass the TDAM. Step 3) Once in position, using a hammer drill with ¼ masonry drill bit, drill through existing mounting plate pre-drilled holes that are attached to bottom of TDAM. Hammer in anchor bolt (Red Head), place washer over plate, then tighten down with nut. Some units may require the use of side mounting tabs as well. Note: Some TDAM s may come with two mounting plates per TDAM. If you need further assistance please call us direct at (888) 526-4736 or email us your questions at: Sales@remfilters.com Figure #1 Figure #2 Figure #3 TRITON TDAMtm Side Mounting Tabs Trench Drain Exit pipe Grate Floor Mounting Tabs Placed 3' to 4' Apart Heavy Sediment SIDE VIEW Over Flow Exit Centered in Trench Drain Placed 4" to 6" before exit TRITON TDAM with center exit pipe Flow Exit Pipe Placed 4" to 6" before exit Single Exit from Trench Drain TRITON TDAMtm TOOLS REQUIRED: 1) Hammer Drill, with ¼ masonry drill bit. 2) Hammer. 3) ¼ X 2" or 3" Concrete Anchors. i.e. (Red Head) 4) 7/16" Socket Drive. 25 4B: Description of installation limitations and non-standard installation procedures One of the common limitations found in the field are catch basin that are too shallow, or the infrastructure is not conducive for a standard Insert filter. We can filter many different types of configurations, but sometimes modifications or custom units are needed to properly capture the target contaminant. When we come across unusual drains, our approach is to always maximize the given catch basin configuration with the largest volume capturing ability. This may lead to a filter that will need to be customized to fit. Typical modifications that may be needed are trimming the devices housings, cutting down the size of the filter, or adding attachments like an extension of stainless steel or HMWPE depending on the device and model type. 4C: Methods for diagnosing and correcting installation errors A visual assessment can be done to determine if the device has not been installed correctly. If needed, the device can simply be removed by lifting and removing the device or removing the anchor nuts and then removing the device. Proper re-installation can take place at that point. All filters should be level and firmly in place. Filters are designed to hold a large amount of trash and sediment, which requires the filters to be well supported. If there is any weakness in the support of the filter, more support will of course be needed. There should also not be any gaps where water can bypass the system during normal storm events. TRITON PERF – FTC Filters have been designed for their ease of installation. If anyone does have installation problems, they may call our offices and we will be glad to help. 1 (888) 526-4736 Section 5: Operation and maintenance information 5A: Device inspection procedures and frequency considerations Each device inspection can be done visually, remove the grate/manhole if needed and assess if the unit is damaged, at what capacity, or experienced a bypass event. REM recommends that devices not on a standard maintenance schedule be inspected 3 times per year or more if needed. 5B: Maintenance frequency considerations due to capacity at various volumes REM recommends that devices be maintained 3 times per year, or as outlined by the governing body. It is recommended that devices do not reach more than 50% capacity without a maintenance event. This frequency is dictated by the loading capacity at each particular drain as well. If not properly maintained, devices will reach 100% capacity and begin the bypass event for debris entering the catch basin. If filters are consistently above 50% full, REM recommends additional maintenance intervals. 5C: Maintenance procedures Secure area (Traffic and pedestrian controls, if needed). Pull grate and set aside. Remove (VAC) debris that has been captured in system. Pressure washing may also be necessary in some cases to remove certain debris. After system has been cleaned. Visually inspect filter for any damaged areas. Take a picture of the cleaned filter for your records. Fill out report if used for the given catch basin. Replace grate. Remove all traffic control devices. 5D: Essential equipment and materials for proper maintenance The maintenance for the TRITON PERF-FTC Filters is accomplished for the most part by using an industrial vacuum truck due to the large capture capacity of the devices. Simply remove the grate and begin to remove the captured debris. The device can be brushed or sprayed off if needed. Take note of the amount of debris collected along with the condition of the device. Vacuum Truck, Grate Pick. 26 5E: Description of effects of deferred maintenance Typical implications of deferred maintenance consist primarily of debris that will begin to bypass the device because it has reached the full capacity of its limitations. If the device has been properly installed and supported, it should continue to remain in the original placement from the initial installation. 5F: Repair procedures for device components In the case that a particular component is damaged, it is advised to call our customer service department for repair or replacement options. Please call (888) 526-4736 for repair or replacement issues. Section 6: Vector Control Accessibility 6A: Date of device submittal to MVCAC Device Fact Sheet was submitted to MVCAC on 11/23/2021 Device Fact Sheet was approved by MVCAC on 12/20/2021 6B: Description or drawing that demonstrates vector control personnel accessibility Drawings continued on next page. This Section Intentionally Left Blank 27 REM Inc. VECTOR CONTROL ACCESSIBILITY MADE INUSA For CPS Filters, access to bottom of catch basin is done through optional Deflector Plate with Elevated Vector Access. Clear and direct opening access. For Insert Filters, access to bottom of catch basin is done through filters Overflow Port. Clear and direct opening access. For Top Hat Filters, access to bottom of catch basin is done through filters Overflow Port. Clear and direct opening access. For Curb Inlet Filters, access to bottom of catch basin can be done through the curb opening or the manhole cover on the curb. For Area Drain Filters, access to bottom of catch basin is done through both normal access and filter Overflow Port. Clear and direct opening access. For TDAM Trench Filters, access to bottom of catch basin is done through both normal access. Clear and direct access. For Models: INSERT-PERF-FTC CPS-PERF-FTC TOP HAT-PERF-FTC AREA DRAINS-PERF-FTC CURB INLET-PERF-FTC TDAM-PERF-FTC **REM TRITON PERF Devices have no moving or swinging parts for abatement access. All devices allow a free and clear access to the bottom of catch basin and lateral lines below, as well as notched bottoms to prevent standing water. 28 For Insert Filters, access to bottom of catch basin is done through filters Overflow Port. Clear and direct opening access. REM Inc. VECTOR CONTROL ACCESSIBILITY MADE INUSA For Models: INSERT-PERF-FTC Grate Overflow Bypass TRITON INSERT FILTER SERIES Side View Bottom of catch basin Easy Access to bottom of catch basins Exit pipe StreetEasy Access to bottom of catch basins Catch Basin Easy Access to bottom of catch basins Triton Insert Filters **REM TRITON PERF Devices have no moving or swinging parts for abatement access. All devices allow a free and clear access to the bottom of catch basin and lateral lines below, as well as notched bottoms to prevent standing water. 29 REM Inc. VECTOR CONTROL ACCESSIBILITY MADE INUSA For Models: TOP HAT-PERF-FTC Grate Overflow Bypass TRITON TOP HAT FILTER SERIES Side View Bottom of catch basin Easy Access to bottom of catch basins Exit pipe StreetEasy Access to bottom of catch basins Catch Basin Easy Access to bottom of catch basins Triton Top Hat Filters For Top Hat Filters, access to bottom of catch basin is done through filters Overflow Port. Clear and direct opening access. **REM TRITON PERF Devices have no moving or swinging parts for abatement access. All devices allow a free and clear access to the bottom of catch basin and lateral lines below, as well as notched bottoms to prevent standing water. 30 For Curb Inlet Filters, access to bottom of catch basin can be done through the curb opening or the manhole cover on the curb. REM Inc. VECTOR CONTROL ACCESSIBILITY MADE INUSA For Models: CURB INLET-PERF-FTC TRITON CURB INLET FILTER SERIES Easy Access to bottom of catch basins Curb Bottom of catch basin Manhole Access Bottom of catch basin Street Access Manhole Access Street Access **REM TRITON PERF Devices have no moving or swinging parts for abatement access. All devices allow a free and clear access to the bottom of catch basin and lateral lines below, as well as notched bottoms to prevent standing water. 31 For Area Drain Filters, access to bottom of catch basin is done through both normal access and filter Overflow Port. Clear and direct opening access. REM Inc. VECTOR CONTROL ACCESSIBILITY MADE INUSA For Models: AREA DRAIN-PERF-FTC **REM TRITON PERF Devices have no moving or swinging parts for abatement access. All devices allow a free and clear access to the bottom of catch basin and lateral lines below, as well as notched bottoms to prevent standing water. Bottom of Drain Easy access to bottom of catch basin Access Area Drain Filter (ADF) shown in a trench drain with a vertical exit pipe. Heavy Sediment OVERFLOW EXIT PIPE Heavy Sediment Area Drain Filter Access Beyond the bottom of the catch basinAccess Access CATCH BASIN AREA DRAIN FILTER (ADF) CAPTURED TRASH & DEBRIS Easy Access with our without Grates Grate Catch basin with a sump containment area. (Designed to capture sediment, hydrocarbons and floatables) Water level Side View Exit Pipe 32 For TDAM Trench Filters, access to bottom of trench drain can be done with or without the grates being in place. Clear and direct access. REM Inc. VECTOR CONTROL ACCESSIBILITY MADE INUSA For Models: TDAM-PERF-FTC Easy Access to bottom of Trench Drains Water Level TDAM s Battery Configuration Grate Side View FlowHeavy Sediment Fallout Flow Overflow Bypass Exit Pipe Exit Pipe Possible Exit Options Easy Access to bottom of Trench Drains Easy Access with our without Grates Grate Access Access (TT2) TDAM Easy Access to different section of trench drain **REM TRITON PERF Devices have no moving or swinging parts for abatement access. All devices allow a free and clear access to the bottom of catch basin and lateral lines below, as well as notched bottoms to prevent standing water. 33 6C: Letter of Verification from MVCAC Revel Environmental Manufacturing, Inc 960 Detroit Ave. Suite B Concord, CA 94518 December 20, 2021 Dear Mr. Fleischmann, Thank you for the submitting the Revel Environmental Manufacturing Inc. Triton PERF-FTC devices for review by the Mosquito and Vector Control Association of California pursuant to the SWRCB Trash Treatment Control Device Application Requirements. The Association has carefully reviewed the conceptual drawings for the Triton Insert PERF- FTC, Triton Top Hat PERF-FTC, Triton Curb Inlet, Triton TDam, and Triton Area Drain devices and verifies that provisions have been included in the designs that allow for full visual access to all areas for presence of standing water, and when necessary, allows for treatments of mosquitoes. While this verification letter confirms that inspection and treatment for the purpose of minimizing mosquito production should be possible with the Revel Environmental Manufacturing Inc. Triton PERF-FTC devices as presented, it does not affect the local mosquito control agency’s rights and remedies under the State Mosquito Abatement and Vector Control District Law. For example, if the installed device or the associated stormwater system infrastructure becomes a mosquito breeding source, it may be determined by a local mosquito control agency to be a public nuisance in accordance with California Health and Safety Code sections 2060-2067. “Public nuisance” means any of the following: 1. Any property, excluding water, that has been artificially altered from its natural condition so that it now supports the development, attraction, or harborage of vectors. The presence of vectors in their developmental stages on a property is prima facie evidence that the property is a public nuisance. 2. Any water that is a breeding place for vectors. The presence of vectors in their developmental stages in the water is prima facie evidence that the water is a public nuisance. 3. Any activity that supports the development, attraction, or harborage of vectors, or that facilitates the introduction or spread of vectors. (Heal. & Saf. Code § 2002 (j).) Declaration of a facility or property as a public nuisance may result in penalties as provided under the Health and Safety Code. Municipalities and the vendors they work with are encouraged to discuss the design, installation, and maintenance of stormwater trash capture devices with their local mosquito control agency to reduce the potential for disease transmission and public nuisance associated with mosquito production. Sincerely, Bob Achermann, MVCAC Executive Director 34 Section 7: Reliability information 7A: Estimated design life of device Under normal operations and with the impact of large storm events, the TRITON PERF-FTC has an estimated lifespan of 20+ years. Naturally occurring elements and mineral saturation do not have a resounding effect on either the Stainless Steel, HMWPE, or ABS used in construction. 7B: Warranty information REM warrants the TRITON PERF-FTC device for 3 years after the installation date. This includes the device and material itself. 7C: Customer support For general regional assistance please contact the following REM representatives: Marcel Sloane Bob Marchant Northern California Regional Manager Southern California General Manager 960 Detroit Ave. Suite B 2110 S. Grand Ave. Concord, CA. 94518 Santa Ana, CA. 92705 (888) 526-4736 (714) 557-2676 Marcel@remfilters.com Bobm@remfilters.com For technical and design information please contact: Daniel Fagan Northern California Operations Manager 960 Detroit Ave. Suite B Concord, CA. 94518 (925) 676-4736 Daniel@remfilters.com Section 8: Field/Lab testing information and analysis All Test units were placed in HIGH trash and debris areas within Contra Costa County. Below are results from initial inspections. *Continued next page. 35 T1: 3 months after installation – capacity Test Unit: T1 - TR14(16) PERF Cartridge – Attached to model TR3648-TH T1: 2 months after installation – capacity Test Unit T1 This TR3648-TH Insert was retrofitted with a TR14(16) PERF Cartridge. Unit is located in Contra Costa County in a Downtown park and restaurant block, which is a high foot traffic and trash area. After 2 inspections the findings were given to governing body at which point a maintenance event was coordinated and performed on the unit. Approximately 60 gallons (13,860 cubic inches) of naturally compacted trash and debris were removed from the catch basin filter insert. ATTACHMENT 3 City standard Trash Capture BMP Exhibit [Use the City’s standard Trash Capture BMP Plan.]