Loading...
HomeMy WebLinkAbout2368 TERRAZA RIBERA; ; CB901153; Permit' B U I L D I N G 08/15/90 11:49 Page 1 of 1 Job Address: 2368 TERRAZA RIBERA Permit Type: SINGLE FAMILY DWELLING Parcel No: 215-582-22-00 Valuation: 174,996 P E R M I T Str: Permit Project Development Fl: Ste: No: CB901153 No: A9001259 No: DEV89063 Construction Type: VN Occupancy Group: R3/M1 Description: PLAN 3 PC Class Code: CT 84-41 90-290 2325 SF 422 Status: Applied: l~~;/v 07/06/90 07/06/90 DC CONTRACTOR : SF GARAGE PHASE 5 LOT 171 L..-01' n \ FIELDSTONE 5465 MOREHOUSE DR #250 SAN DIEGO, CA 92121 FIELDSTONE CORPORATION OWNER *** Fees Required *** *** Apr/Issue: Validated By: Lie. C 402826 619-546-8081 Lie. OWNER Fees Collected & Credits *** --------------------------------------------Fees: Adjustments: Total Fees : Fee description Building Permit Plan Check Strong Motion Fee 11,978.00 .oo 11,978 .00 Enter 'Y' to Autocalc P.F.F. F.M.F./G.M .F. and Zone(99) Enter 'Y' to Autocalc Lacosta TIF Enter 'Y' to Autocalc Bridge Fee or manually enter M.F.F . Enter Park-in-Lieu Dist#(9) twice * BUILDING TOTAL Enter "Y" for Plumbing Issue Fee > Each Plumbing Fixture or Trap > Each Building Sewer > Each Water Heater and/or Vent > Gas Piping System > Each Vacuum Breaker > * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Single Phase Per AMP > * ELECTRICAL TOTAL ($10 Minimum) Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts > Each Install/Reloc Appliance Vent > Each Hood/Fireplace > * MECHANICAL TOTAL Total Credits: Total Payments: Balance Due: Units Fee/Unit 310.00 1713.00 4.00 .0 2.50 1.00 6.50 1.00 2.50 1.00 2.50 2.00 2.50 100.00 .25 1.00 9.00 4.00 4.50 2.00 6.50 .00 250.00 11,728.00 Ext fee Data 902.00 586.00 12.00 6125.00 310.00 670.00 530.00 1713.00 983.00 11831 .00 7.50 37.50 6.50 2.50 2.50 5.00 62.00 5.00 25.00 30.00 15.00 9.00 18.00 13.00 55.00 y 06 y y y y y 02 1 728-00 PERMIT# CB901153 DESCRIPTION: PLAN 3 PC SF GARAGE CITY OF CARLSBAD INSPECTION REQUEST FOR 08/05/91 90-290 2325 SF 422 INSPECTOR AREA MP PLANCK# CB901153 OCC GRP PHASE 5 LOT 171 TYPE: SFD JOB ADDRESS: 2368 TERRAZA RIBERA APPLICANT: FIELDSTONE COMPANY CONTRACTOR: FIELDSTONE OWNER: FIELDSTONE CORPORATION REMARKS: MH/RUDY/529-9964 PAGER SPECIAL INSTRUCT: TOTAL TIME: CD 19 29 39 49 LVL DESCRIPTION ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical ***** INSPECTION DATE DESCRIPTION ACT 052491 Exterior Lath/Drywall AP 052491 Interior Lath/Drywall co 050791 Rough Combo AP 050391 Shear Panels/HD's AP 050191 Rough/Topout AP 042991 Rough/Topout NR 042691 Rough/Topout NR 042391 Roof/Reroof AP 121490 Ftg/Foundation/Piers AP 121090 Underground/Under Floor AP CONSTR. TYPE NEW STR: FL: STE: PHONE: 5468081 PHONE: 619-546-8081 PHONE: D I INSPECTOR Ms, l ~4 ~ COMMENTS HISTORY ***** INSP COMMENTS MP MP TAPED W/0 INSPECTION MP MP OK TO WRAP MP MP MP MP MP MP FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING s PLANNING U/M PLAN CHECK#: CB901153 PERMIT#: CB901153 PROJECT NAME: PLAN 3 PC 90-290 2325 SF 422 SF GARAGE PHASE 5 LOT 171 ADDRESS: 2368 TERRAZA RIBERA CONTACT PERSON/PHONE#: MARK/438-0468 SEWER DIST: LC WATER DIST: CA WATER DATE: 07/26/91 PERMIT TYPE: SFD ----------------------------------------------------------=============-===== ~~~PECTEE:;c~ INSPECTED BY: INSPECTED BY: COMMENTS: DATE INSPECTED: k/9/j / APPROVED y_ DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED DISAPPROVED DISAPPROVED DISAPPROVED FINAL BUILDING IN,SPECTION ENGINEERING FIRE ~U/M PLAN CHECK#: CB901153 DEPT: BUILDING PERMIT#: CB901153 PROJECT NAME: PLAN 3 PC SF GARAGE 90-290 2325 SF 422 PHASE 5 LOT 171 ADDRESS: 2368 TERRAZA RIBERA CONTACT PERSON/PHONE#: MARK/438-0468 SEWER DIST: LC WATER DIST: CA WATER DATE: 07/26/91 PERMIT TYPE: SFD -======---====----==-------------------------=-----=---===-====--===--===--== INSPECTED DATE # APPROVED ~ DISAPPROVED BY: Q27Z-INSPECTED: INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPRQVED DISAPPROVED =======---====-----=------------------=------------=----==----===--========== COMMENTS: FINAL BUILDING INSPECTION DEPT: BUILDING ~-- ENGINEERING FIRE PLANNING~ WATER PLAN CHECK#: CB901153 DATE: 07/26/91 PERMIT#: CB901153 PERMIT TYPE: SFD PROJECT NAME: PLAN 3 PC 90-290 2325 SF 422 SF GARAGE PHASE 5 LOT 171 ADDRESS: 2368 TERRAZA RIBERA CONTACT PERSON/PHONE#: MARK/438-0468 SEWER DIST: LC WATER DIST: CA INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: APPROVED DISAPPROVED APPROVED DISAPPROVED =============-------=======------------------================================ COMMENTS: s1n..1;e.,rs-C I{ - ----;.~-~ BUILDING INSPECTION DEPT: BUILDING ENGINEERING PLAN CHECK#: CB901153 PERMIT#: CB901153 FIRE PLANNING PROJECT NAME: PLAN 3 PC 90-290 2325 SF 422 SF GARAGE PHASE 5 LOT 171 ADDRESS: 2368 TERRAZA RIBERA CONTACT PERSON/PHONE#: MARK/438-0468 SEWER DIST: LC WATER DIST: CA U/M WATER DATE: 07/26/91 PERMIT TYPE: SFD ===----=====-----------------------------------------------====-============- INSPECTED O /.~ DATE BY: /. • INSPECTED: 7-30· 'ii APPROVED DISAPPROVED >< INSPECTED 0~~ DATE 'iJ •9•'1I ~ BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED COMMENTS: ;OU{i.t./C. 'X /11,111 ,<'() .,I 1"1~,1, 7' .s NOT Com,l?w,!'rG DEPT: BUILDING ENGINEERING FIRE PLANNING U/M /4TER, FINAL BUILDING INSPECTION _ ~) PLAN CHECK#: CB901153 ~ 07/26/91 PERMIT#: CB901153 PERMIT TYPE: SFD PROJECT NAME: PLAN 3 PC 90-290 2325 SF 422 SF GARAGE PHASE 5 LOT 171 ✓ ADDRESS: 2368 TERRAZA RIBERA CONTACT PERSON/PHONE#: MARK/438-0468 SEWER DIST: LC WATER DIST: CA ========================================================7================== INSPECTED ~ DATE 9 BY: •· INSPECTED: o-6 -1 APPROVED DISAPPROVED INSPECTED BY: INSPECTED BY: ' ---- DATE INSPECTED: DATE INSPECTED: APPROVED APPRGVED DISAPPROVED DISAPPROVED =============================================----=--===-===============-===== COMMENTS: SDUTH■RN CALIFORNIA SDIL AND T■STING, INC. 8280 RIVERDALE STREET. P.O. BOX 20B27. SAN DIEGO, CALIFORNIA 92120 (B 1 BJ 280-4321 67B ENTERPRISE STREET, ESCONOIOO. CALIFORNIA e202e (B1 B] 746-4~44 REPORT OF COMPRESSION TESTS Fit E NUMBER 8912271 DATE .JOB Alga Hills January 3, 1991 ASTM (C39) ~CONCRETE 0 MORT...,R I I i L I •\OORESS 2368 Terraza Ribera -Lot 171 lh/VN ER A.:::;iCHtTECT Robert Bowlus Associates E".JGINEER JEM II I CONTRAC"TOR Fieldstone/Ben F. Smith, Inc. ! CJCATrlJN IN STRUCTURE c:Er\/!f-NT Slab-on-grade -Lot 171 I I Pozz !\/11 >< '"' l □i::1 PRO PORTIONS I fll\,1f:: i.''J MIXER Mlf',,JUTES '.·)L l.i'.l!P 1NCHES Sorrento Ready Mix Sorrento Ready Mix 500016 60 0 GROUT 0 GUNI TE D 4-1/4 I 0 AaR,c:ATcD sv AA T<aucK ND 102 TICKET ND 141035 L T_e=s~te,~d=b""y=: =D=J=====,=====,=====r============r====T'~----, I I ABORATORY NO I MARK 7918 7919 7920 I--~ -~ --=-----t----1-------jC-------j------j-----+----j i □ATE l'v1AOE CATE RE'CEIVEO :-=:,AT[ ~ESTEO C A:\,1 t... TER_ INCHES Ao::q::::A SQ INCHES r'v1AX1MUM LOAD. LBS CC::l'v1PRESS1VE STA PSI Ac;e Tf-~STEO. DAYS Rf=Q C PSI AT 28 DAYS I __ J"', T v'VT/cu FT (PLASTIC} 12-27-90 12-18-90 1-03-91 6.00 28.27 58,000 2,050 7 2,500 01S TRIBU TION (3) Ben F. Smith, Inc. (1) JEM III (1) City of Carlsbad (1) Sorrento Ready Mix 1-24-91 74,000 2,620 28 Discarded SOUTHERN CALIFORNIA SDIL AND TESTING, INC. REVIEWED BY ' Michael B. Wheeler, R.C.E. #45358 -IIC ,..,CIIICID IIMICINtY A )I W\ ' •, -MW I ILi ff,. P. 0. -_, ---CM.w--· ..... -..all NO. 2 1122, I ::-..::~ .................................... " □ S1'IUCT. STIIL AINlel.Y □ ILUI• L•. , ... 1CATICII □ •1W«-CID G'fPUI □ OTNH □ PILI o•nt1Ne ................ -........................... . .S c s r IMSf''M. DATI LOCATIONS 01' •O•K INS(lllfCTfO, TEST UMPLU TAUN, W()ttl( •tJ!CTEO. JOa ,..O.L!MS, (lllltOG•tss •• , .... u . nc. INC1.uoai.tN~o• .. • TION ••ouT -.... OUN Tl O~ ... T ............ AC coo• wo•• .... ~o-•oi ........... T••·· a IOIINT. NO·•· O~ TIIIT • .: .... ,. T•••N1 t T•ucT. CONNIICTIONI I Wlll.01 .... 011 .... T. •O1.T• To•ou•o• CMIIC•IIDI t:TC. '-~ :It - /(, ""3 /c., l/ / -~ C. '.> I "' 2 3 4 0 l b 7 .). '3 '-{ t/ lb tY 2 s '-If' I ? ~3,s-i__ -2YSG. ,;)3~8 ;J..3 72. I ......, CIIT..., TNAf I NAVI WICJ9 ML WCN. UNlla cm.Nia ..,.. I MW COW\Y Wint lNI AMtO.-IUNI, INClflCA IICTIONI OP TMI OOVIIIIIIII Wit• IA- , I . , ,, '< 90 II /'7 ,. , ' CrJ 00 11.3.,- ,, , , ~B '10 / I S-2 I, ,, C !!> 'fo l / zo ,, . ,, Cd "lo " S-3 ' I . ' C (J ,t> I I JC,, /AC:/Z'#&A 1°F,VI _.1-..... GEOCON l"C O RPOkATll!O ',, ' , 7'.,~ "-iL.---i Fl)UNDATION OBSERVATION REPORT JOB NAME:_..i: ...... ·h !c ...... ~':'1 .......... //_,.~.._1/$ ________ _ LOCATION: ,.:..,,""5 I& 1 I 7t:,,r@.-t/vo 17'2 · (ADDRESS, LOT NUMBER/BUILDING NO., ETC.) FILE NO.: 3&''16 -Jq, ot/ DATE: !2 /1';/1C- PERMIT NO.: PLAN Fll..E NO.: ePURPOSE OF OBSERVATION: 13:1 Verify soil conditions exposed are similar to those anticipated. I;!: Footing excavations extend to proper depth and bearing strata. □ Verify foundation reinforcement complies with minimum recommended in soil report. fi't Verify slab reinforcement, sand bedding and moisture barrier comply with minimum recommended in soil report. □ Other: ------------------------------ e SOIL REPORT RECOMMENDATIONS BASED ON: ~ Expansion Condition; □ VERY LOW □ LOW l:ia' Fill Geometry qt,:f&.czl--,~ fr ..,,,_,_, lo 0 MEDI'UM z:-e ?S:/ tifHIGH 0 VERY HIGH □ Other: ____________________________ _ e MINIMUM FOUNDATION RECOMMENDATION: Footing Depth: 0 12 INCHES O 18 INCHES JX1. 24 INCHES OTIIER: ____ ,....... _____ _ Footing Reinforcement: □ NO. 4 T&B □ 2-N0.4 T&B □ NO.S T&B OTIIER: 1'?Js t . 7 ,9.,,5,-e>J,, ..... ,?( Interior Slab Reinforcement: □ ~10;10 □ 6x6-6/6 □ NO. 3 @ 24 INCHES □ NO. 3 @ 18 INCHES Slab Bedding Material and Thickness: S,mo,, "-1 11 Vapor Barrier: l«S?N-e~, . e FOUNDATION PLAN REVIEWED: If yes, identify and describe: e OBSERVATI 1Z1. Su (! Su □ 0 a:\ wpjob\dnft.ina\ fdnobrp(.100 conformance with Soil Report (see "Purpose of Observation"). onnance with Foundation Plans.