HomeMy WebLinkAbout2359 TERRAZA RIBERA; ; CB901145; Permit• .. ..
~8;1s>90 11:49
Page 1 of 1
B U I L D I N G
Job Address: 2359 TERRAZA RIBERA
Permit Type: SINGLE FAMILY DWELLING
Parcel No : 215-582-30-00
Valuation: 174,996
PERMIT Permit No: CB901145
Project No: A9001251
Development No: DEV89063
Str: Fl: Ste:
Construction Type: VN
Occupancy Group : R3/M1
Description : PLAN 3 PC
: SF GARAGE
Class Code:
90-290 2325 SF 42
PHASE 5 LOT 179
CT 84-41
JSSCle),
status : z zrnoVBI!)
Applied: 07/06/90
Apr/Issue : 07/06/90
Validated By: DC w:rr ,1q
CONTRACTOR FIELDSTONE
OWNER
***
5465 MOREHOUSE DR #250
SAN DIEGO, CA 92121
FIELDSTONE CORPORATION
Fees Required ***
Fees:
Adjustments :
Total Fees:
Fee description
Building Permit
Plan Check
Strong Motion Fee
11,978.00
.00
11,978.00
Enter 'Y' to Autocalc P.F .F.
F.M.F./G.M.F. and Zone(99)
***
Enter 'Y' to Autocalc Lacosta TIF
Enter 'Y' to Autocalc Bridge Fee
or manually enter M.F.F.
Enter Park-in-Lieu Dist#(9) twice
* BUILDING TOTAL
Enter "Y" for Plumbing Issue Fee >
Each Plumbing Fixture or Trap >
Each Building Sewer >
Each Water Heater and/or Vent >
Gas Piping System >
Each Vacuum Breaker >
* PLUMBING TOTAL
Enter "Y" for Electric Issue Fee >
Single Phase Per AMP )
* ELECTRICAL TOTAL ($10 Minimum)
Enter 'Y' for Mechanical Issue Fee>
Install Furn/Ducts >
Each Install/Reloc Appliance Vent >
Each Hood/Fireplace >
* MECHANICAL TOTAL
Lie. C 402826 619-546-8081
Lie. OWNER
Fees Collected & Credits ***
Total Credits:
Total Payments:
Balance Due:
Units Fee/Unit
1713.00
4.00
15.00 2.50
1.00 6.50
1.00 2 .50
1.00 2.50
2.00 2.50
100.00 .25
1.00 9.00
4.00 4.50
2.00 6.50
.00
250.00
11,728.00
Ext fee Data
902.00
586.00
12.00
6125.00
310 .00
670.00
530.00
1713.00
983.00
11831.00
7.50
37.50
6.50
2 .50
2.50
5.00
62,00
5.00
25.00
30.00
15 .00
9,00
18.00
13.00
55.00
y
06
y
y
y
y
y
7437 08/.15/90 000:J
r '72 0
•
PERMIT# CB901145
DESCRIPTION: PLAN 3 PC
SF GARAGE
TYPE: SFD
CITY OF CARLSBAD
INSPECTION REQUEST
FOR 08/16/91
90-290 2325 SF 422
PHASE 5 LOT 179
JOB ADDRESS: 2359 TERRAZA RIBERA
APPLICANT: FIELDSTONE COMPANY
CONTRACTOR: FIELDSTONE
PHONE:
PHONE:
OWNER: FIELDSTONE CORPORATION PHONE:
INSPECTOR AREA MP
PLANCK# CB901145
OCC GRP
CONSTR. TYPE NEW
FL: STE: STR:
5468081
619-546-8
REMARKS: MH/RUDY/529-9964
SPECIAL INSTRUCT: INSPECTOR ~ii'---'~~-+---------
TOTAL TIME:
CD
19
29
39
49
LVL DESCRIPTION ACT COMMENTS
ST Final Structural 1
PL Final Plumbing ~
EL Final Electrical
ME Final Mechanical
--
***** INSPECTION HISTORY *****
DATE DESCRIPTION ACT INSP COMMENTS
081391 Final Combo co MP COPPER LEAK
061091 Interior Lath/Drywall AP PY
060791 Interior Lath/Drywall NR MP
052491 Rough Combo AP MP
051791 Gas/Test/Repairs AP MP
051791 Rough/Topout AP MP
051691 Gas/Test/Repairs AP MP
051691 Rough/Topout AP MP
051691 Shear Panels/HD's PA MP OK TO WRAP
050991 Roof/Reroof AP MP
050391 Roof/Reroof AP MP
121090 Ftg/Foundation/Piers AP MP
112990 Underground/Under Floor AP MP
DEPT: BUILDING
FIN~L ILDING INSPECTION •··. \
ENGINEERIN~ R PLANNING U/M
PLAN CHECK#: CB901145
PERMIT#: CB901145
PROJECT NAME: PLAN 3 PC 90-290 2325 SF 422
SF GARAGE PHASE 5 LOT 179
ADDRESS: 2359 TERRAZA RIBERA
CONTACT PERSON/PHONE#: MARK/438-0468
SEWER DIST: LC WATER DIST: CA
WATER
DATE: 07/26/91
PERMIT TYPE: SFD
====================------------------========---------======================
INSPECTED ~ DATE
BY: Q{~ ( INSPECTED: <i'/1/9( APPROVED )£_ DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
=====================-========================------=========================
COMMENTS:
FINAL BUILDING---HfflP CTION
DEPT: BUILDING ENGINEERING
PLAN CHECK#: CB901145
PERMIT#: CB901145
/ ~----
FIRE PLANNING
PROJECT NAME: PLAN 3 PC 90-290 2325 SF 422
SF GARAGE PHASE 5 LOT 179
ADDRESS: 2359 TERRAZA RIBERA
CONTACT PERSON/PHONE#: MARK/438-0468
SEWER DIST: LC WATER DIST: CA
U/M WATER
DATE: 07/26/91
PERMIT TYPE: SFD
INSPECTED DATE # APPROVED/ BY: INSPECTED: DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
================-----------------------------------------===-===============-
COMMENTS:
DEPT: BUILDING
FINAL BUILDING INSPECTION
ENGINEERING FIRE PLANNING ~ WATER
'LAN CHECK#: CB901145
PERMIT#: CB901145
PROJECT NAME: PLAN 3 PC 90-290 2325 SF 422
SF GARAGE PHASE 5 LOT 179
ADDRESS: 2359 TERRAZA RIBERA
CONTACT PERSON/PHONE#: MARK/438-0468
SEWER DIST: LC WATER DIST: CA
DATE: 07/26/91
PERMIT TYPE: SFD
======================-1==============================~/==============
INSPECTED 0 DATE .,
BY: (/ / INSPECTED: ', 1-'1/ APPROVED__ DISAPPROVED_
INSPECTED
BY:
INSPECTED
BY:
DATE
INSPECTED:
DATE
INSPECTED:
APPROVED
APPROVED
DISAPPROVED
DISAPPROVED
=================================---==========-----=======----===============
COMMENTS:
-
.-·· · -'FINA) BUILDING INSPECTION
DEPT: BUILDING (.;;NEERING// FIRE PLANNING U/M
PLAN CHECK#: CB90-l-145 -
PERMIT#: CB901145
PROJECT NAME: PLAN 3 PC 90-290 2325 SF 422
SF GARAGE PHASE 5 LOT 179
ADDRESS: 2359 TERRAZA RIBERA
CONTACT PERSON/PHONE#: MARK/438-0468
SEWER DIST: LC WATER DIST: CA
~~~PECTED .P:'r: ;;;> DATE
INSPECTED: 7-10-'9/
INSPECTED 0/.P. DATE g-9~,1 BY: INSPECTED:
INSPECTED DATE
BY: INSPECTED:
APPROVED
APPROVED
APPROVED
WATER
DATE: 07/26/91
PERMIT TYPE: SFD
DISAPPROVED
:L DISAPPROVED
DISAPPROVED
JI-
=================-===--------------------------------------------============
FINAL BUILDING INSPECTION /
DEPT: BUILDING ENGINEERING FIRE PLANNING U/M~
PLAN CHECK#: CB901145
PERMIT#: CB901145
PROJECT NAME: PLAN 3 PC 90-290 2325 SF 422
SF GARAGE PHASE 5 LOT 179
vADDRESS: 2359 TERRAZA RIBERA
CONTACT PERSON/PHONE#: MARK/438-0468
SEWER DIST: LC WATER DIST: CA
DATE: 07/26/91
PERMIT TYPE: SFD
======================================================= 7===================
INSPECTED tJ& DATE
BY: ,L,o,"' INSPECTED: J/&-9) APPROVED 0__ DISAPPROVED __
INSPECTED
BY:
INSPECTED
BY:
COMMENTS:
DATE
INSPECTED:
DATE
INSPECTED:
APPROVED DISAPPROVED
APPROVED DISAPPROVED
SOUTHl!RN CALIFORNIA SOIL AND Tl!STING, INC.
6280 RIVERDALE STREET, P.O. BOX 20B27, SAN DIEGO, CALIFORNIA 92120 {B 1 BJ 2B0-4321
678 ENTEAPRISE STREET, ESCONDIDO, CALIFORNIA 82023 {B19) 746-4~44
REPORT OF COMPRESSION TESTS
FILE NUMBER 8912271 DATE· December 19, 1990 ASTM ( C39) C!I CONCRETE
.JOB Alga Hills
ADDRESS 2355 Terraza Ribera (179)
OWNER
ARCHITECT Robert Bowlus Associates
ENGINEER JEM I I I
CONTRACTOR Fieldstone
LOCATION IN STRUCTURE
CEMENT
SANO
ROCK
MIX NO OR PROPORTIONS
TIME !N MIXER. MINUTES·
SLUMP, INCHES
FABRICATED SY
Tested bv: DJ
S. E. corner of slab-on-grade
II
Sorrento
Sorrento
S500016/5 sack
60
5
MS TRUCK N□· 74
0 MORT ...... R
□GROUT
0 GUNITE
D
Permit #CB901145
TICKET NO 137181
LABORATORY NO 7365 7366 7367
MARK #2
DATE MADE
DATE RECEIVED
DATE TESTED
OIAMETF.:R, INCHES
Al=IEA SQ INCHES
MAXIMUM LOAD, LBS
COMPAESSIVE STR. PSl
AGE Tf::STEO, DAYS
RE'□ 0 PSI AT 28 DAYS
UNI r \/'.IT/cu FT (PLASTIC]
12-12-90
12-13-90
12-19-90
6.00
28.27
56,750
2,010
7
2,500
01STR1SuTION (J)
( 1)
( 1)
( 1)
Ben F. Smith, Inc.
JEM I II
City of Carlsbad
Sorrento
SOUTHERN CALIFORNIA
SOIL AND TESTING, INC.
REVIEVVEO BY w~w
Michael B. Wheeler, R.C.E. #45358
GEOCON I
I :"J (; 1) ll ,. n, I( ' r ,: I} ·----
FOUNDATION OBSERVATION REPORT
JOB NAME: I ) /,i,, //,'//s
✓
LOCATION: lo~. 17(· 17 1. n n · 17r:; ,1,<V ,1~1, /f,?, 1,a.3 J:Pl -
(,illD,RESS. LOT ~ff\ER/BUlLD[NG NO.'. ETC)
PE!Uv!ITNO.: PLAN FILE NO.:
ePURPOSE OF O DSERVATION:
Ef
,~
Verify soil conditions exposed are similar to those anticipated.
Footing excavations extend to prorer depth and bearing strata.
□
IS]
Verify foundat ion reinforcement complies with minimum recommended in soil report.
Verify slab reinforcement, sand bedding and moisture barrier comply with minimum
recommended in soil report.
□ Other: ____________________________________ _
Vrtr-1•,, I
I
e SOIL REPORT RECOMMENDATIONS BASED ON:
.~· Expansion Condition; fSl VERY LOW C2J LOW
Fill G r. , II. : ; i I.. , JS] eometry (,11r ,t ,, ·l11• r,c-,-:-o• -,.,,.,, ,
, I /4 ~~ < :,rl,.: f,-1• } /, 11,'/ /4-
DATE: ·,u ,1f.
□ HIGH 0 VERY HIGH
I
<'If{•"· )fr/,'-7;'.-J,,t.T,. { t
□ Other:-----------------------,----------
./{/ L" f.'5 -11'!4 c',,·l uy"J tr1:
e MINIMUM FOUNDATION RECOMMENDATION: ( 1; '
Footing Depth: a1, l:! rNCHES ~ 18 INCHES □ 2-1 INCHES OTII ER: I rt:,: il, )'/,fl -:;J{lf 111 r /ft ,:,,,-/,,,..(.,
Footing Reinforcement: 0 NO. -1 T&B O 2-N0.-1 T&l3 0 N0 .5 T&D OTHER: }~[ I : o, ,, ,, ,,-(
Interior Slab Reinfo rcement: 0 6x6-10/IO □ 6x6-6/6 0 NO. 3@ 24 INCHES □ NO. J@ LB INCHES
Slab Bedding Material and Thickness: f./ 11 Vapor Barrier: ( : so,-.. -r ••
e FOUNDATION PLAN REVIEWED: YES D
If yes, identify and describe:
e OBSERVATfONS:
!SJ Substantial confo rmance with Soil Report (see "Purpose of Observation").
·□ Substantial conformance with Foundation Plans. □ Other: ,,(/I (r-G q.,...-· ,✓--,✓,,,,,,_,/ ,~-I ; .(,~ ,,,·d<'J'/t..'✓,_,.
r' "'t .. <'F /'r-v .,., t: h r ... , ,,-r / .. <J ,_/ ,_ I_"' , l Y. ·' / /4,. "' , L.t-._,,
(c;,1:,,/ ,
• COMMENTS: -7 -; ;~ 10,-.. ,.-, ,...,.(,, / ti.,, I ,.,
~ ·.· t ,.
7
\ < I ) /)
I ', · ! / C { ··• ( I \ r <
n: \ wpjob\dr~11.ing\(Jnob'1'l. l 00 GEOCON REPrlfSENTATIVE