HomeMy WebLinkAbout2356 TERRAZA RIBERA; ; CB901120; Permit08/15~0 11:47
Pa~e 1 of 1
B U I L D I N G
Job Address: 2356 TERRAZA RIBERA
Permit Type: SINGLE FAMILY DWELLING
Parcel No: 215-582-21-00
,aluation: 143,262
P E R M I T
Str:
Permit
Project
Development
Fl: Ste:
No : CB901120 1
No: A9001226
No: DEV89063 •
Construction Type: VN
Occupancy Group: R3/M1
Description: PLAN 1 PC
Class Code: CT 84-41
90-290 1875 SF 459
Status:
Applied:
ISSUED
07/06/90
08/15/90
DC
: SF GARAGE PHASE 5 L 170
CONTRACTOR
0)1' liO
FIELDSTONE
OWNER
5465 MOREHOUSE DR #250
SAN DIEGO, CA 92121
FIELDSTONE CORPORATION
*** Fees Required ***
Fees:
Adjustments:
Total Fees:
Fee description
Building Permit
Plan Check
Strong Motion Fee
10,687.00
.00
10,687.00
Enter 'Y' to Autocalc P.F.F .
F.M.F./G.M.F. and Zone(99)
***
Enter 'Y' to Autocalc Lacosta TIF
Enter 'Y' to Autocalc Bridge Fee
or manually enter M.F.F.
Enter Park-in-Lieu Dist#(9) twice
* BUILDING TOTAL
Enter "Y" for Plumbing Issue Fee >
Each Plumbing Fixture or Trap >
Each Building Sewer >
Each Water Heater and/or Vent >
Gas Piping System >
Each Vacuum Breaker >
* PLUMBING TOTAL
Enter "Y" for Electric Issue Fee >
Single Phase Per AMP >
* ELECTRICAL TOTAL ($10 Minimum)
Enter 'Y' for Me chanical Issue Fee>
Install Furn/Ducts >
Each Install/Reloc Appliance Vent>
Each Hood/Fireplace >
* MECHANICAL TOTAL
Apr/Issue:
Validated By:
Lie. C 402826 619-546-8081
Lie. OWNER
Fees Collected & Credits ***
Total Credits :
Tot al Paymen ts :
Balance Due:
Units Fee/Unit
• 0
1.00
1.00
1.00
2.00
100.00
1.00
4.00
2 .00
2.50
6.50
2 .50
2.50
2.50
.25
9.00
4.50
6.50
7437 08/
.00
250.00
10,437.00
Ext fee
794.00
516.00
10.00
Data
5014.00 Y
310.00 06
670.00 Y
530.00 Y
1713 .00
983.00
10540.00
7 .50 Y
37.50
6.50
2.50
2 . 50.
5.00
62 .00
5.00 Y
25.00
30.00
15.00 Y
9.00
18.00
13.00
55.00
.,. 02
1041:
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad CA 92009 (619)
PERMIT# CB901120
DESCRIPTION: PLAN 1 PC
SF GARAGE
TYPE: SFD
CITY OF CARLSBAD
INSPECTION REQUEST
FOR 08/06/91
90-290 1875 SF 459
PHASE 5 LOT 170
JOB ADDRESS: 2356 TERRAZA RIBERA
APPLICANT: FIELDSTONE COMPANY
CONTRACTOR: FIELDSTONE
PHONE:
PHONE:
OWNER: FIELDSTONE CORPORATION PHONE:
STR:
INSPECTOR AREA MP
PLANCK# CB901120
OCC GRP
CONSTR. TYPE NEW
FL: STE:
5468081
619-546-8081
REMARKS: MH/MARK/438-0468 INSPECTOR
SPECIAL INSTRUCT:
TOTAL TIME:
CD
19
29
39
49
DATE
LVL DESCRIPTION
ST Final Structural
PL Final Plumbing
EL Final Electrical
ME Final Mechanical
DESCRIPTION
*****
052191 Interior Lath/Drywall
052191 Exterior Lath/Drywall
050791 Rough Combo
050391 Shear Panels/HD's
050191 Rough/Topout
042991 Rough/Topout
042691 Rough/Topout
042391 Roof/Reroof
121490 Ftg/Foundation/Piers
120790 Underground/Under Floor
ACT COMMENTS
~-----
INSPECTION HISTORY *****
ACT INSP COMMENTS
AP MP
AP MP
AP MP
AP MP OK TO WRAP
AP MP
NR MP
NR MP
AP MP
AP MP
AP MP
FINAL BUILDING INSPECTION -----. ---
DE PT: BUILDING ENGINEERING & PLANNING U/M
PLAN CHECK#: CB901120
PERMIT#: CB901120
PROJECT NAME: PLAN 1 PC 90-290 1875 SF 459
SF GARAGE PHASE 5 LOT 170
ADDRESS: 2356 TERRAZA RIBERA
CONTACT PERSON/PHONE#: MARK/438-0468
SEWER DIST: LC WATER DIST: CA
~~~PECTE~~ DATE
.:::: INSPECTED:
INSPECTED DATE
BY: INSPECTED:
INSPECTED DATE
BY: INSPECTED:
WCJdt APPROVED
APPROVED
APPROVED
RECEIVED J li ~ 3 0 199f
WATER
DATE: 07/26/91
PERMIT TYPE: SFD
)s_ DISAPPROVED
DISAPPROVED
DISAPPROVED
=====================================---------===============================
COMMENTS:
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING
PLAN CHECK#: CB901120
PERMIT#: CB901120
FIRE~ U/M
PROJECT NAME: PLAN 1 PC 90-290 1875 SF 459
SF GARAGE PHASE 5 LOT 170
ADDRESS: 2356 TERRAZA RIBERA
CONTACT PERSON/PHONE#: MARK/438-0468
SEWER DIST: LC WATER DIST: CA
WATER
DATE: 07/26/91
PERMIT TYPE: SFD
===================--------------------------------------------==============
INSPECTED '3/71/1~ DATE ~ DISAPPROVED BY: INSPECTED: qpc, APPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
==========-----===================------------------------------------=======
COMMENTS:
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING FIRE PLANNING ~WATER
.'LAN CHECK#: CB901120 DATE: 07/26/91
PERMIT#: CB901120 PERMIT TYPE: SFD
PROJECT NAME: PLAN 1 PC 90-290 1875 SF 459
SF GARAGE PHASE 5 LOT 170
ADDRESS: 2356 TERRAZA RIBERA
CONTACT PERSON/PHONE#: MARK/438-0468
SEWER DIST: LC WATER DIST: CA
INSPECTED
BY:
INSPECTED
BY:
INSPECTED
BY:
COMMENTS:
);UA-7'.'f'E -( ((_
cSeWf..12..-( I'.
s
DATE
INSPECTED:
DATE
INSPECTED:
DATE
INSPECTED:
APPROVED
,==7================
_V_ DISAPPROVED
APPROVED DISAPPROVED
APPROVED DISAPPROVED
_ --EINAL BUILDING INSPECTION
DEPT: BUILDING (ENGINEERING FIRE PLANNING U/M
~ PLAN CHECK#: CB901~~0~-
PERMIT#: CB901120
PROJECT NAME: PLAN 1 PC 90-290 1875 SF 459
SF GARAGE PHASE 5 LOT 170
ADDRESS: 2356 TERRAZA RIBERA
CONTACT PERSON/PHONE#: MARK/438-0468
SEWER DIST: LC WATER DIST: CA
INSPECTED ~/.?. DATE
BY: /-• • INSPECTED: 7-J c:, • "} I
INSPECTED 0/.fl DATE ,a.q.'j', BY: INSPECTED:
INSPECTED DATE
BY: INSPECTED:
COMMENTS: /H d',1C-..Z:&,'~t7 V4'H?IM7".S l'Vc:77'
APPROVED
APPROVED
APPROVED
C6'""1,,.,.7'1:
WATER
DATE: 07/26/91
PERMIT TYPE: SFD
DISAPPROVED
L DISAPPROVED
DISAPPROVED
-/.
FINAL BUILDING INSPECTION ··e.-/ •
DEPT: BUILDING ENGINEERING FIRE PLANNING U/M ATER
PLAN CHECK#: CB901120 E: 07/26/91
PERMIT#: CB901120 PERMIT TYPE: SFD
PROJECT NAME: PLAN 1 PC 90-290 1875 SF 459
SF GARAGE PHASE 5 LOT 170
/ADDRESS: 2356 TERRAZA RIBERA
CONTACT PERSON/PHONE#: MARK/438-0468
SEWER DIST: LC WATER DIST: CA
=============--------===================-=----============~=============-----
INSPECTED m DATE 6-fc-91 ✓ BY: INSPECTED: APPROVED DISAPPROVED ' , ~G
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
=-============-------=====------------------------------------=---------=====
COMMENTS:
I
' I
' '
BOUTHl!RN CALIFORNIA BOIL AND Tl!BTING, INC.
6280 RIVERDALE STREET. P.O. BOX 20827. SAN DIEGO. CALIFORNIA 92120 (61 9) 280-4321
678 ENTERPRISE STREET. ESCONOIOO, CALIFORNIA 9202~ (B 1 SJ 746-4544
REPORT OF COMPRESSION TESTS
FILE NUMBER 8912271 DATE: December JOB Alga Hills
;.'.l.00RESS 2356 Terraza
OWNER
Ribera -Lot 170
ARCHITECT Robert Bowlus Associates
ENGINEER JEM I II
CONTRACTOR Fieldstone
LOCAT1QN IN STRUCTURE
CEMENT
N. W. corner of slab-on-grade
II AOl\,11 X TL_ RE
SC.NO
RC,Cr<
27, 1990 ASTM (C39) ~ CONCRETE
0 MORT ... R
□GROUT
0 GUNITE
D
Permit# CB901120
i M1 X ~"G O!=l PRO PORTIONS
Sorrento
Sorrento
S500016/5 sack
100 '
5 LTll\,1E 1,"J Ml><ER. MINUTES
SL.L,MP INCHES
FABRICATED BY
Tested bv: DJ MS TAUCK NO 84
LABOl=lATORY NO
MARK
DATE MADE
DATE RECEIVED
DATE ,..ESTED
OIAME TF.:R. INCHES
;.'.l.R E ,:i. SQ INCHES
MAXIMUM LOAD, LBS
COMP,:::lESS1VE STR, PSI
AGE TESTED. DAYS
RE=Q O PSI AT 28 DAYS
UNIT vv r/c u FT (PLASTIC]
7686
12-18-90
12-19-90
12-26-90
6.00
28.27
75,250
2,660
8
2,500
01STR1Bu TION (3) Ben F. Smith, Inc.
(1) JEM III
(1) City of Carlsbad
(1) Sorrento Ready Mix
7687
1-15-91
85,000
3,010
28
TlCKET NO 139226
7688
Discarded
,....-
SOUTHERN CALIFORNIA
BOIL AND TESTING, INC.
REVIEWED BY:
Michael B. Wheeler, R.C.E. #45358
I
'
r ' I
I
BOUTHl!RN CALIFORNIA BOIL AND TESTING, INC.
62B0 RIVERDALE STREET. P.O. BOX 20627. SAN DIEGO. CALIFORNIA 92120 {61 SJ 280-4321
678 ENTERPRISE STREET. ESCONDIDO. CALIFORNIA 8202~ (8 19) 746-4544
REPORT OF COMPRESSION TESTS
FILE NUMBER 8912271 □ATE December 27, 1990
COB Alga Hills
AOORE:SS 2356 Terraza Ribera
OvVNER
ARCHITECT Robert Bowlus Associates
ENG!NEER JEM III
CONTRACTOR Fieldstone
L.OCAT10N IN STRUCTURE
CEMENT
ADMIX Tc_,RE
S,c.N □
RCJCi<
MIX r,_,u OA PROPORTIONS
N. W. corner of slab-on-grade
I I
ASTM (C39) ~ CONCRETE
0 MORT ...... R
0 GROUT
0 GUNITE
D
Permit# CB901120
LTl!'V1E:: IN Mr><ER, MINUTES
SLL,MP 1NCHES
FABl=l•CATEO BY
Tested bv: DJ
Sorrento
Sorrento
S500016/5 sack
100
5
MS TAUCK NO 84 TICKET NO 139226
LABOAATORY NO
MAAK
0.C..TE MADE
DATE RECEIVED
DATE TESTED
01AME TER. INCHES
AREA SD INCHES
MA XiMUM LOAD, LBS
COMPRESSIVE STR, PSI
AGE TESTED. DAYS
Rf"Q C PSI AT 2B DAYS
U"-.)1 T vvT/Cu FT (PLASTIC)
7686
12-18-90
12-19-90
12-26-90
6.00
28.27
75,250
2,660
8
2,500
01STR1BuTtON (3) Ben F. Smith, Inc.
{l) JEM Ill
(1) City of Carlsbad
{1) Sorrento Ready Mix
7687 7688
SOUTHERN CALIFORNIA
BOIL ANO TESTING, INC.
REVJE W-ED BY
Michael B. Wheeler, R.C.E. #45358
-
;.
, --•DEUff,.11,0. _ _,
........ CMJP ......... a.41b
"°· 811:12, I :::..-:r:.. ..................................... "
□ S111UCT, STIii. AftD&'( Q &&a•L•. ,,_1CATICII
□ IIIIW.CIO G'fPUI □ OTNI•
□ "LI D•IVING ............................................. .
oa,c•••• ... .,.'-· ,,.,. ••••N. •••-•••o• • .. ~•-· ••'-0-1100. a Tc.,
' '
:Sc s'
LOCATIONS 01' •O•K INSIIICT!O, TUT SAMIILU T AKIN. •O•K •tJ!CTIO. JOe ... O.LIMS, ll110G•1u .• , .... u . ITC.
, .. c'-uoa:i.tN"o•,.• TtON ••ouT -•..ouN T• o,. ... Ta•••'-•'-•c ao o• wo•• •••,.o-•oi Nuw•••· .,.,•&. • ,oaNT. NO'■.
0 .. Ta•T ., .... , ,. T•••N1 9TIIUCT. CONNaCTION9 ·••1.oit .. •o• .... T. •O\.TI T0•-•01 CNac••Da • ., ••
'-~ !it,
/(.,, s
/c, </
/ -'.> 5 <-
I (o Cc, 2 3 40
lb 7 .2 -g'-{t{
I 1af-25 '-(y
~JS-7....
,lsS(..
17/ .;)3{.,8
.,2..]72.
I ..... C.aTlf'f '"4f I MVI INll'IQID Ml a,,
WCllt. UNUa onawtll NOTIO, I MW
COMl'I.Y Wint M AMIOVllt PIANI. INClflCA
IICftONI Of TMI GCWaMlllt IUIUMIG V.WI.
, f . ,,
, I "I
I• , '
,, , . c.B '10 / I S-2
,, ,, C .!3 'TOI/ zo
// 'I Cd 1'0 11 S-3
, f > I
............ ..,.. ...
GEOCON
t,.COR r ORA T.:O
FOUNDATION OBSERVATION REPORT
JOB NAME: ,+J~"l //,-/)~
LOCATION: !..✓,-rs IG~ /7 < ~4:0 172 -
(ADD T NUMBER/BUILDING NO., ETC.)
FILE NO.: 3~·'16 -c:-q, 0 L./
DATE: /2. _/ 170/ 1C-
PERMIT NO.: PIAN FILE NO.:
ePURPOSE OF OBSERVATION:
~ Verify soil conditions exposed are similar to those anticipated.
~ Footing excavations extend to proper depth and bearing strata.
D · Verify foundation reinforcement complies with minimum recommended in soil report.
&I. Verify slab reinforcement, sand bedding and moisture barrier comply with minimum
recommended in soil report.
□ Other: ------------------------------
e SOIL REPORT RECOMMENDATIONS BASED ON:
~ Expansion Condition; 0 VERY LOW O LOW
~ Fill Geometry e1 ,¾ c:z/-, ~ fr ~ te 00 HIGH 0 VERY HIGH 0 MEDIUM
z::e ?::?: , D Other: ____________________________ _
e MINIMUM FOUNDATION RECOMMENDATION:
Footing Depth: 0 12 INCHES D 18 INCHES .18124 INCHES OTIIER:. ___ __,,,,__ _____ _
Footing Reinforcement: 0 NO. 4 T&B O 2-N0.4 T&B O N0.5 T&B OTHER: ,~s t -T 0,.,5,~p~-..._e r
Interior Slab Reinforcement: 0 6x6-10/10 0 6x6-o/6 0 NO. 3 @ 24 INCHES O NO. 3 @ 18 INCHES
Slab Bedding Material and Thickness: S,mo,, 3/11 Vapor Barrier: fti'Sft:<-<e,.,, .
e FOUNDATION PLAN REVIEWED: YES □
If yes, identify and describe:
e OBSERV
!Z1. ~
D
a:\ wpjob\ draft.int\ (dnobrpt..100
ormance with Soil Report (see "Purpose of Observation").
ormance with Foundation Plans.