Loading...
HomeMy WebLinkAbout245 ACACIA AVE; ; CBRA2023-0051; PermitBuilding Permit Finaled ( City of Carlsbad Residential Associated Permit Print Date: 08/21/2023 Job Address: 245 ACACIA AVE, CARLSBAD, CA 92008-3206 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: 2042400800 Track#: Valuation: $90,000.00 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Occupant Load: Plan Check#: Code Edition: Sprinkled: Project Title: Description: DEMOLITION OF (2) EXISTING SMALL HOMES (11,250 SF) FEE DEMOLITION OF BUILDING: RESIDENTIAL SB1473-GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -RESIDENTIAL (SMIP) Demo Total Fees: $607.70 Total Payments To Date: $607.70 Building Division Permit No: Status: CBRA2023-0051 Closed -Finaled Applied: 04/26/2023 Issued: 04/26/2023 Finaled Close Out: 08/21/2023 Final Inspection: 06/05/2023 INSPECTOR: Renfro, Chris Balance Due: AMOUNT $592.00 $4.00 $11.70 $0.00 Pagelofl 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov ( Cicyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check Est. Value PC Deposit C BA-tr ·2 o.2.? -CIV 5 I Date Job Address,___;2_'-/..:....:;_7....:.,/4-...::.f....:./J..;.C_/,4.;___,4-_V_£_. _____ Unit:. ____ APN:. ________ _ CT/Project #: __________________ ,Lot #: ____ Year Built: _________ _ BRIEF DESCRIPTION OF WORK: 17,er,t,Pu -r,o,-.1 OF c'.?> ,f lYtJll'U. l,Hw~f> 1/1 '2fo {"-~~. 0 New SF: Living SF, ____ Deck SF, ___ Patio SF, ____ Garage SF __ _ Is this to create an Accessory Dwelling Unit? O Y O N New Fireplace? O YON, if yes how many? ___ _ D Remodel: SF of affected area Is the area a conversion or change of use? O YON ----- □ Pool/Spa:. _____ SF Additional Gas or Electrical Features? ____________ _ 0Solar:. ___ KW,, ___ Modules, Mounted:QRoofQGround, Tilt: 0Y0 N, RMA:OY ON, Battery:OYO N, Panel Upgrade: OYON Electric Meter number: ___________ _ Other: APPLICANT (PRIMARY CONTACT) PROPERTY OWNER Name:f?,,.-trJr-1 /f,fK-fi Name: _________________ _ Address: 'rJI~ J/p,y/q,,l .et'(t:1tv/lt ~ddress:. _______________ _ City: C:':akl> State: C./1-Zip: q,zp~ City:. _________ State: ___ .Zip: ____ _ Phone:~91 ~ 7ft,-u,;zo ~ Phone:. _______________ _ Email: ;f;f;tt,cll a ,Kr!Y'~/'r~.CJ.P/11 Email: _______________ _ DESIGN PROFESSIONAL CONTRACTOR OF RECORD Name:, __________________ Business Name:. ________________ _ Address: Address:, _________________ _ City: ________ .State: ___ Zip: ____ _ City: _______ State: ___ ,Zip: ______ _ Phone: _________________ _ Phone: __________________ _ Email: _________________ _ Email: __________________ _ Architect State License: ___________ _ CSLB License #: _______ Class:. ______ _ Carlsbad Business License# (Required): _______ _ APPLICANT CERTIFICATION I certify that I have read the app/Jcat1on and state that the above 1nformat1on 1s correct and that the mformatron of the plans 1s accurate I a::::m;;:;::1)~,tya,d,;:;;la;l:;;wldmgcoa,::::, ~ r DATE: 2 t '3 1635 Fa,aday Ave Caclsbad, CA 92008 Ph 442-339 2719 f REV. 04122 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I herebyaff irm under penalty of perjury that I am I icensed under provisions of Chapter 9 ( commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. I a/so affirm under penalty of perjury one of the following declarations (CHOOSE ONE}: ~ have and will maintain a certificate of consent to sel ~rk which this permit is issued. PolicyNo. ___ --;~~---J.'--t-4'---,f.---c;>.~,._,--_ ____________________________ _ -OR- DI have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name:-------------------------• Policy No. ____________________________ Expiration Date: _________________ 1 -OR- D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code}. Lender's Name: _______________________ Lender's Address: ________________________ _ CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the appl'1cat'1on is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one anotl1er; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All::::,;::;;:~;: the pcopecty wm;;_;ted ic cocdacce wit~;'~'::~::~':"'"'' at t timrtcoctioc "°'"' 0 ::~::oted'(,/ ,< &, /z 2 Note: If the person signing above is an authorized agent for the contra 'd er of authorization on contractor letterhead. f ' , -OR- (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR- DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: AND, D FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I rriust have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have bl.Jilt as an owner-builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted or at the foflowing Web site: http://www./eginfo.ca.gov/calaw. html. OWNER CERT/FICA TION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilit1es/ut1lity easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans Inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. NAME (PRINT): SIGN: __________ DATE: ______ _ Note: If the erson si nin above is an authorized a ent for the ro ert owner include form B-62 si ned b ro ert owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339~2719 Email: Building@carlsbadca.gov 2 REV. 04/22 Building Permit Inspection History Finaled (city of Carlsbad PERMIT INSPECTION HISTORY for (CBRA2023-0051) Permit Type: BLDG-Associated Permit Residenti, Work Class: Demo Status: Closed -Finaled Application Date: 04/26/2023 Owner: Issue Date: 04/26/2023 Subdivision: PALISADES #2 Expiration Date: 12/04/2023 IVR Number: 48620 Address: 245 ACACIA AVE CARLSBAD, CA 92008-3206 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 06/05/2023 06/05/2023 BLDG-11 213130-2023 Passed Chris Renfro Monday,August21,2023 Foundation/Ftg/Piers (Rebar) Checklist Item BLDG-Building Deficiency NOTES Created By Angie Teanio COMMENTS Demo TEXT 949-910-3510 Chad BLDG-Final Inspection 213252-2023 Passed Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Structural Final BLDG-Electrical Final COMMENTS Demo completed Chris Renfro Passed Yes Created Date 06/02/2023 Passed Yes Yes Yes Yes Complete Complete Page 1 of 1 NOISl/1I0 8NI07In8 0\>'8SltJV'.J :JO All'.J €202 9 g ~dV COMPREHENSIVE AS~lffi93~ SURVEY REPORT FOR 245 Acacia Carlsbad, CA Prepared for Rincon DATE 12/09/2022 Report# 2212-091-942222 CONDUCTED BY Jackson Environmental 120 Tustin Ave C-1121 Newport Beach, CA 92663 949-230-9779 Mjacksonenvironmental@gmail.com TABLE OF CONTENTS INTRODUCTION SECTION I ASBESTOS SURVEY SUMMARY Executive Summary Facility Description Survey Findings SECTION II BUILDING INSPECTION FOR ASBESTOS Bulk Sampling Bulk Sample Analysis Quality Assurance Limitation of Sampling Suspect Asbestos Containing Materials SECTION Ill LABORATORY REPORTS Asbestos Laboratory Reports INTRODUCTION Jackson Environmental was retained by Rincon to conduct a COMPREHENSIVE Asbestos survey for the property located at 245 Acacia, Carlsbad, CA, on November 14th, 2022. The purpose of this survey was to identify Asbestos Containing Material (ACBM) in all areas of the building. Work consisted of collecting bulk samples of All materials suspect of containing asbestos. THE REPORT The survey report is divided into three major sections, which provide identification of all suspected ACBM. Section I presents a summary of the Asbestos Survey and a general description of the area inspected. Survey findings are also provided in this section. Section II describes the methodology used to perform the survey and includes Jackson Environmental, and our Analytical quality control procedures. Section Ill of this report summarizes the locations and materials which were identified as containing asbestos. Results of the bulk samples are included in this section. SECTION I ASBESTOS SURVEY SUMMARY EXECUTIVE SUMMARY Jackson Environmental was retained by Rincon, to conduct a COMPREHENSIVE Asbestos Survey for the property located 245 Acacia, Carlsbad, CA. The sampling was conducted by Michael Jackson an Osha certified asbestos consultant # 04-3635 FACILITY DESCRIPTION The subject property is a single family, one story, wood frame building, set on a foundation. While on-site the Certified Personnel noted the condition of the materials. This is noted in the survey findings below. SURVEY FINDINGS The following building materials were identified and or assumed as containing asbestos: Building Material Location Friable/NonFriable/ Condition SQ' A~~roximate ect. Mastic Kitchen Non Friable G 200 Interior Plaster <1 % Throughout Non Friable G 2000 Exterior Plaster <1 % Stucco Non Friable G 2000 **Please note square footages are approximate estimates only and should not be used as a basis for bidding purposes** RECOMMENDATIONS: All Significantly Damaged and Damaged areas should be repaired or removed as soon as possible to avoid any potential hazards that may result from further disturbance of ACM. SCAQMD's Rule 1403 requires a Procedure 5 Work Plan for any unscheduled asbestos fiber release episode involving ACM or Class II non-friable ACM. SECTION II COMPREHENSIVE ASBESTOS INSPECTION BULK SAMPLING Bulk samples of areas containing suspect ACBM were collected. A homogeneous area is defined as surfacing material, thermal insulation, or miscellaneous material that is uniform in color, texture, or date of application. Samples were collected using wet methods; where they are deemed appropriate, to minimize fiber release. Prior to sampling, the location is misted with water from a spray bottle. A sample of the suspect material is then collected using a chisel, core borer, knife, or other appropriate tool. After the sample was collected, the bulk material was placed in a sample bag which was sealed to prevent fiber release or contamination by outside sources. Samples are documented by entering the sample data on a bulk log, including a description of the material, a unique sample number is assigned to each sample and the sample bag was labeled with that number. During the survey, the technician also notes the condition of the material being sampled, its location, condition, and friability. Note: The amended National Emission Standard for Hazardous Air Pollutants (NESHAP), November 20, 1990, included a requirement that when the asbestos content of a bulk sample material is determined using procedures outlined in the Interim Method and the asbestos content is estimated to be less than 10% by method other than Point Counting, the parties legally responsible for a building (owner/operator) may elect to assume the amount to be greater than 1 % and treat the material as a regulated asbestos containing material. If the owner or operator does not want to assume the material is asbestos containing, verification of the amount of asbestos by the Point Counting method may be required. The purpose of this procedure is to minimize false negative analysis, and false positive. Point Counting was included in NESHAP in response to an HEPA study that found unacceptable amounts of false positive and false negative analyses by methods outlined in the Interim Method. Unless otherwise directed, American Analytical will assume that PLM analysis is acceptable for this survey. CLASSIFICATION OF BULK BUILDING MATERIALS "S" Significantly Damaged Material with one or more of the following characteristics: The surface is crumbling or blistered over at least one tenth of the surface if the damage is evenly distributed :( one quarter or more if the damage is localized). One tenth (one quarter or more, if localized) of material hanging from the surface, deteriorated, or showing adhesive failure. Water stains, gouges, or mars over at least one tenth of the surface if the damaged is evenly distributed (one quarter or more if the damage is localized). Accumulation of powder, dust, or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. We recommend immediate removal of Significantly Damaged material and clean up of the area by a Licensed Asbestos Abatement Contractor. "D" Damaged Material with the following characteristics: The surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one tenth of the surface ii the damage is evenly distributed (less than one quarter if the damage is localized). Accumulation of powder, dust, or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. We recommended removal of damaged material and clean up of the area by a Licensed Asbestos Abatement Contractor. "G" GOOD Material with no visible damage or deterioration. or showing only very damage or deterioration. We recommended materials identified as in good condition be placed on an Operations and Maintenance Program (0 & M). BULK SAMPLE ANALYSIS All bulk samples were analyzed by Patriot Laboratory 1041 S. Placentia Ave, Fullerton, CA, 92831. Phone# 714-607-5227, an NVLAP accredited laboratory. The laboratory accreditations are as follows: NVLAP #200642-0 National Voluntary Laboratory Accreditation Program (Federal) Approximately 10% of the bulk samples were split for quality control purpose. All bulk samples were analyzed by Polarized Light Microscopy (PLM) with dispersion staining in accordance with the EPA Method #600/R-93/116. 40 CFR 783.87. The reliable limit of detection for PLM is 1.0%. Where "None Detected" or ND appears in the report, it should be interpreted as meaning that no asbestos was observed in the sample. Samples containing, "Trace" level of asbestos indicates a possible contamination and is considered ACBM. NOTE: If a sample contains greater than 1.0% asbestos, it is a regulated material by Federal Government Standards. Under the California State Education Code, materials containing greater than 0.1 % in asbestos content are considered regulated. QUALITY ASSURANCE Statement of Quality Assurance At Jackson Environmental Quality Assurance is priceless! Jackson Environmental is committed to providing analytical services and data to its clients that are of the highest quality and legally defensible. Quality Assurance (QA) procedures were employed to ensure reliable results for analysis of bulk samples as follows: The laboratory is currently participating in the NVLAP Quality Assurance Program. Quality control is processed on at least 10% of all bulk samples on a daily basis. Laboratory results of samples submitted to the laboratory were within 3% of the original side by side sample. LIMITATION OF SAMPLING OF SUSPECT ASBESTOS CONTAINING MATERIAL Reasonable effort is made by Jackson Environmental 's staff to locate and sample suspect materials. However, for any facility the existence of unique or concealed asbestos containing material and debris is a possibility. In addition, sampling and laboratory analysis constraints typically hinder the investigation. American Analytical does not warrant, guarantee, or profess to have the ability to locate or identify all asbestos containing materials in any given facility. This report is intended to be used in planning for construction or demolition. This report is not intended to be a construction document. Jackson Environmental is not, and has no responsibility as, a generator, operator, treater, storer, transporter or disposer of hazardous materials or waste found or identified as a result of Jackson Environmental's work. STATE REQUIREMENTS In accordance with State of California Regulation, all surveys are conducted by personnel holding a minimum of a Site Surveillance Technician certificate. This certificate is awarded to individuals who have fulfilled specific educational and experience requirements, as well as having completed extensive training in asbestos specific courses. Additionally, the State also mandates these individuals pass a rigorous examination. This examination is prepared, proctored, and graded by State officials. The Certified Asbestos Consultant must fulfill all the education and experience requirements as the Site Surveillance Technician but must have additional and more extensive asbestos related training. Candidates for Certified Asbestos Consultant must also pass a more rigorous examination before being approved by the State of California. In compliance with State of California Requirements surveys and reports prepared by a Certified Site Surveillance Technician are reviewed, approved, and signed by a Certified Asbestos Consultant. Certified Asbestos Consultant Michael Jackson Project Manager CAC # 04-3635 949-230-9779 Report # 2212-092-942222 Certificate of Analysis PLM Asbestos Identification Jackson Environmental 120 Tustin Ave C-1121 Newport Beach, CA 92663 Date Collected: Date Received: 11/15/2022 Date Analyzed: 11/17/2022 Date Reported: I I/ 18/2022 Lab/Client ID/Layer Location 942222-001 Kitchen Total Asbestos None Detected 942222-002 Kitchen 2 Total Asbestos None Detected 942222-003A Kitchen 3 Total Asbestos None Detected 942222-0038 Kitchen 3 Chrysotile 2 % Total Asbestos 2 942222-004 Living Room 4 Chrysotile <I % Total Asbestos <1 % % tel -114-601-1117 Ire• -!SS-%8-Jlll ~[lab•!l'!Ji-Otlab.com DATnl~T LAB 1041 I. Plii!enliaA,eou,,firlJ,rto,, [A 91831 1--" I ■,1 ~ Report Number: Project Number: Prl~ject Name: Project Location: Collected By: Claim Number: PO Number: 942222 245 Acacia 245 Acacia Carlsbad, CA Number of Samples: 16 Material Description Color Flooring Brown Flooring Brown Flooring Brown Mastic Brown Black Interior Plaster White Green Composition ( % ) 90% Non- Fibrous Material 10% Glass Fibers 9WY'c Non- Fibrous Material 10% Glass Fibers 90% Non- Fibrous Material 10% Glass Fibers 98% Non- Fibrous Material !00% Non- Fibrous Material P<1ge I of4 Certificate of Analysis PLM Asbestos Identification Jackson Environmental 120 Tustin Ave C-1121 Newport Beach, CA 92663 Date Collected: Date Received: I 1/15/2022 Date Analyzed: I 1/17/2022 Date Reported: I I /I 8/2022 Lab/Client ID/Layer Location 942222-005 Bedroom I 5 Chrysotile <I % Total Asbestos <1 942222-006 Bedroom 2 6 Chrysotile <I % Total Asbestos <I 942222-007 Living Room 7 Total Asbestos None Detected 942222-008 Bedroom 1 8 Total Asbestos None Detected 942222-()()9 Bedroom 2 9 Total Asbestos None Detected 942222-010 Side 10 Chrysotile <l % Total Asbestos <I % % % tel -114-&0Mlll Ire! -815-91,lHill l)(lab.iijlll!iotlilb.tom I n A ~,~T LAB 104lS.!'la,,nl.iAv.mi,.f•l~rtoo,{A911lll I.-,... I'-. ~ Report Number: 942222 Project Number: Project Name: 245 Acacia Project Location: 245 Acacia Carlsbad, CA Collected By: Claim Number: PO Number: Number of Samples: 16 Material Description Color Composition ( % ) Interior Plaster White Green 100% Non- Fibrous Material Interior Plaster White Green 100% Non- Fibrous Material Acoustic White Beige 100% Non- Fibrous Material Acoustic White Beige 100% Non- Fibrous Material Acoustic White Beige 100% Non- Fibrous Material Ext Plaster Tan Grey 100% Non- Fibrous Material Page 2 of 4 Certificate of Analysis PLM Asbestos Identification Jackson Environmental 120 Tustin Ave C-1121 Newport Beach, CA 92663 Date Collected: Date Received: 11/15/2022 Date Analyzed: 11/17/2022 Date Reported: 11/18/2022 Lab/Client ID/Layer Location 942222-01 I Rear I I Chrysotile <I % Total Asbestos 942222-012 Front 12 Chrysotile <I % Total Asbestos 942222-013 Roof 13 <1 <1 Total Asbestos None Detected 942222-014 Roof 14 Total Asbestos None Detected 942222-015 Roof 15 Total Asbestos None Detected % % t'1l -114-60)-1111 tree -85l-%1H512 O(tab:,:f>'!li~ll•bxom n A "l"'r.9:l~T LAB 1041 S. 1'1arnnlii! im,11, foll,rtoa, (A 91ill 1--". I 1,1 ~ Report Number: Project Number: Project Name: Project Location: Collected By: Claim Number: PO Number: 942222 245 Acacia 245 Acacia Carlsbad, CA Number of Samples: 16 Material Description Color Ext Plaster Tan Grey Ext Plaster Tan Grey Roofing Black Roofing Black Roofing Black Composition ( % ) 1 00o/r) Non- Fibrous Material 100% Non- Fibrous Material 80% Non- Fibrous Material 20% Glass Fibers 80% Non- Fibrous Material 20% Glass Fibers 80% Non- Fibrous Material 20% Glass Fibers Page 3 of 4 Certificate of Analysis PLM Asbestos Identification Jackson Environmental 120 Tustin Ave C-1121 Newport Beach, CA 92663 Date Collected: Date Received: 11/15/2022 Date Analyzed: 11/17/2022 Date Reported: 11/18/2022 Lab/Client ID/Layer Location Carla Ruiz -Analyst Report Number: Project Number: Project Name: Project Location: Collected By: Claim Number: PO Number: 942222 245 Acacia 245 Acacia Carlsbad, CA Number of Samples: 16 Material Description Color Composition ( % ) Kwin Sheena Legaspi -Lab Manager-Approved By Bulk sampk(s) submiHcd was (were) analy7cd in accordance with the procedure outlined in the US Federal Register 40 CFR 763. Subpart f, Appendix A: EPA-600/R"93/l 16 {Method for Determination of Asbestos in Building Materials). and EPA-600/M4-82-020 (US EPA Interim Method for the Determination of Asbestos in Bulk Insulation Samples). Samples were analyzed using Calibrated Visua] Estimations (CVES); therefore, results may not he reliable for samples of low asbestos rnncentration levels. Samples of wall systems containing discrete and separable layers are analyzed separately and reported as composite unless ~pccifically rc4uested by the customer to report analytical results for individual layers. This report applies only to the items tested. Results are representative of the samples ;.ubmitted and may not represent the entire material from which the samples were collected. "None Detected" means that no asbestos was observed in the sample. "< 1 %"" (less than one percent) or Trace means that asbestos was observed in the ~ample hut the concentration is below the quantifiable level of 1 % . This report was i;.sue<l by a NIST/NVLAP (Lab Code 200358-0) and CADOHS-ELAP (Cert. No. 2540) accredited laboratory and may not be reprodwxd, except in full without the expressed written consent of Patriol Environmental Laboratory Services. Inc. This report may not be used to claim product certification. approval or endorsement by NIST, NVLAP, ELAP or any govemmenl agency ASB_Rcp_8. l 4 Page 4 of 4 REPORT NUMBER (Lab Use Only) q Ll 1.:z..:1----L I CHAIN OF CUSTODY COMPANY INFORMATION Company Name: Jackson Environmental Project No.: Contact Person: Michael Jackson Project Name: Company Address: Project Location: 1 PATRIOT LAB FULLERTON I LOS ANGELES I SAN DIEGO I SAN JOSE Tel: (888)743-0998 • Email: laboratory@patriotlab.com PROJECT INFORMATION . POii: ' -7u.~ Ar-°",,.!°' . :l,.'f .5 -1c. le.-r-'\ f'_,-..r I<.{,~ ·---- Contact Phone: Sample(s) Collected By: l Date: .. Email(s) For Special Instructions: T.est to fi~ positive Report: Turnaround Time D1HR 0 3HR O6HR Dz4HR 0 48 Hir' nul!R: OsoAv (Busir1ess Hours/Days) ANALYSIS REQUESTED ► FUNGI BACTERIA ---~ ~~I.M'IBiJH;,/llllestos) 0 PLM POINT COUNT 400 ~ Viable (Colony ID & Enum~ration) □ PRESENCE/ABSENCE ---.,, 9 0 D SWAB/BULK ' sa Iii EPA 600/M4-82-020 □ PLM POINT COUNT 1000 0 Tot.14 Coliform & E.coli - "' EPA 600 / R-93 / 116 m Non-Viable surface Surfuces, SWllbs, and Bidk J m 0 PCM (Fiber Count) 0 GRAVIMETRIC REDUCTION 0 Sollds. Uqulm Coon- ~ a: □ TAPE LIFT/SWAB/BULK potable, fflNl-.waslewatllr) u N\OSH 7400 i □ AIR SPORE TRAP ~ LEAD BY RAME AA -EPA 3050B/7420mod, NIOSH 7082mod 0 PAINT □ DUSTWIPE 0 SOILS/SOLIDS □AIR □ WATER (non-potable) Iii i LEAD WASTE PRDALE (by Flame AA) D Check here to perform ALL THREE tests necessary for disposal (S-7 Days TAT) ... :c • 0 TTLC ONLY (Total Threshold by EPA 30508 mod) 0 STLC/CAL WET ONLY (CCR Ch11, A,t;cle 5, App II) □ TCLP ONI.Y (EPA 1331)· u NOTE: Pleose proVlcle approx. 200 gr~imS{appl'OX:½ lb.) of Sample for complete profile. 0 ROTOMETER CALIBRATION Total Rotometers: □ pH TESTING (Soils, solids, liqulds, misc.) EPA 9045 • • IFOR AIR SAMPLES ONLY!) le 'ii I!. Description of Sample ~ ,": LDcadon Sampled (Material Type, Dimensions, start Stop Total A'I. Total .I! ~ etc.) Time Tlme Min. R-Vol. .. , . fl L,. : J_,.. {, (.) ) . y /('(-,,,) A L, ? 0 I_\ ' // ,, / ;"/ ..... I', I' 1/ ,, I/ i.l b 1,...: V" )~ irQi~,..,, -, ·•ti,~,~,,. .{)/q-;1' ,, t; I 1"-,c.olf l'~(),,N\ I \' , I 6 I 'R e ,J A"\, Q, "1 -z_. " r 7 /7 1 ' ,. .,r, vO(}~ I -A /' -.. -<t.,. ,.., I &, 17 Y\ oo.l r~ ,,i,\ f " // q ."/ . h ~ ,A ,-n,\l,"" "1 \\ '/ Rellnqu/shed By: {Prir1t) imo Relinquished By: (Print) (Sign) Michael Jackson (Date) (Time}~ (Date) (Time) ' r I Received By: ~~!\ ~\L'~\ RecellJed By: (Print) (Sign) (D'1\. \ f:;, ?Jo (TI"to (Date) (Time} Method of Shipment l Preservation During Shipment: Condition of Samples: Acceptabte -u,u Comments: "'•· v.G.22.2022 1 REPORT NUMBER (Lab Use Only/ ~~ 1, =r::-ci,, .J PROJECT NAME: _______ _ PROJECT NUMBER: _______ _ ' PA1Rl0TLAB FULLERTON I LOS ANGELES I SAN DIEGO I SAN JOSE Tel: {888)743-0998' Email: laboratory@patrlotJab.com ~ -~., (FOR AIR SAMPLES ONLYI) -;A,·,·' .... • • ... 15.c J! Description ofSample To.I.I - E-LDcation Sampled (Material Type, Dlmensions, Start .... Total '• .ii Stop Flow etc.) Time Time Min. .. .. Vol. • a I°' .; ,~Ao s::-~ {)l,,,.c;h / I [>J t<J?o.✓ ,, If 7 fl, T1-<>,Nf \' ,, ") /'1 ,fc:,," ( ~Q,~f.::-'"' /' L/-/') . ''-/ I/ I ,, ,,, I '1 I', t\ // \\ I/ . .. Relinqulshlld By: (Print) <~n Relinquidled By: (Print) (Sign) Michael Jackson (Date) (Time) (/ tDate} (Time) . . ' ' Recelv.d By: .. \'H~v~VWI (Sit JVL, Received By: jPrtnt) {Sign) 16a -l:y) r {Time) ;>;---(Date)· (Time) v.15 . .U.ztl22 Notes: Patriot's holding time for all samples submitted 30 days for solid samples, 7 days for digests, and immediate for lead in air after analytical results are reported. Unless customer provides written instructions to extend holding time, samples will be disposed of in accordance with local, state, and federal law. *3 Hour Turnaround Time available until 2pm PST. Gravimetric Reduction requires minimum 10 HR Turnaround Time. Viable fungi samples require minimum S-7 days Turnaround Time. Bacterial cultures require minimum 30 HR Turnaround Time. STLC/CAL-WETand TCLP require mlnlmum 72 HR Turnaround Time. 2 ' • -----------------. -------SAN DIEGO REGIONAL OFFICE USE ONLY 0 HAZARDOUS MATERIALS RECORD ID# PLAN CHECK# ~-. ,. QUESTIONNAIRE I I ~""oc BP DATE Business Name ,, -------------81.lsiness Contact -·----Tele~one# Vick Construction Company L')'le Vick 9 9-501-2555 Project AddreSs (include suite) c~ State Zip Code APN# 245 Acacia Ave ' arlsbad Ca 92008 t-.Aailing Address (inctude suite) City State Zip Code Plan Ftle# 12942 Leith Way Yucaipa Ca 92399 Project Contact Applicant E-mail Telephone# Lyle Vick Lvle@vick.construction 909-501-2555 The following questions represent the facility's acttvltln, NOT the speclflc project descr1ption. PART I: ARE DEPARTMENT~ HAZARDOUS MATI;RIALS DIVISION: OCCUPANCY CLASSIFICATION: !not regulred for projeets within the City 'lf San Qinstl: lnc:ltcate by orcl,ng _the item, ~ether your business wdl use, process, or store any of the following hamrdous materials. If any of the items are arcled. applicant must contad the Fire Protection Agency with jurisdiction prior to plan submittal. Oeeupancy Rating: Facility's Square Footage (including proposed project): 1. Expk)s!ve or Blasting Agents 5. Organic Peroxides 9. Water Reaclives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 3. Flammable/Combustible Liquids 7. Pyrophorics 11, Highly Toxic or Toxic Materials 4. Flammable Solids 8. Unstable Reactives 12. Radioactives 13, 14, 15, Corrosives Other Health Hazards None of These. Questions ts yes, applicant must contact the County o San Diego Hazardous Materials Division, 550 Over1and Avenue, urte 1 an Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 1. 2. 3. 4. 5. 6. 7. 8. YES NO (for new construction or remodeling projects) § ~ Is your business listed on the reverse side of this form? {check all that apply), □ § D " WiO your business dispose of Hazardous Substances or Medical Waste in any amount? ..., Will your business store or handle Hazardous Substances in quantiUes greater than or equal to 55 gallons, 500 pounds and/or 200 cubic reet? 0 Win your business store or handle carcinogens/reproductive toxins in any quantity? 0 Win your business use an existing or install an underground storage tank? ~ WiO your business store or handle Regulated Substances (CalARP)? [ZJ WiD your business use or install a Hazardous Waste Tank System (Title 22, Article 10}? 0 Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act), 0 CalARP Exempt I Date Initials 0 GalARP Required I Date Initials 0 CalARP Complete I Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT APCD: The following questions are intended to identify the majority of air ution tsSues at e p nning stage. our project may require a itiona measures not identified by these questions. Residences are typically exempt, except~ single building with more than four dwelling units and those with more than one detached residential buildings on the property-e.g. granny flats [+Exdudes garages & small outbuildings nol used as dwelling units]. If yes is answered for the questions below please see link for further instructions: here or for more comprehensive requirements, please contact apcdcomp@sdapcd.org or call (858) 586--2650. YES NO 10 □ 2,0 □ 3.□ 4.0 Will the project disturb 100 square feet or more of existing building materials? If yes, submit an asbestos survey to apcxlcomp@sdapcd.org. Wdl any load supporting structural members be removed? . If yes, submit an asbestos survey and demolition notification to apcdall'np@sdapc:d.org at least 10 WOfking days priOf' to starting lhe demo~tion of a load bearing structure. A notification Is required even if no asbestos is present in the structure. {ANSWER ONLY IF QUESTION 1 IS YES) Will 100 square feet Of' more of friable asbestos material be disturbed? If yes, submit a notification of asbestos removal to apcdcomp@sdapcd.org at least 10 working days prior to starting asbestos removal. Wdl any equipment or operations be installed that may require an APCD Permit to Operate? Please see the reverse side of this tom, for typical equipment requiring an APCO permit. If yes, contact APCD prl°' to the issuance of a building pennit. Briefly describe business activities: Briefly describe proposed project: 3 new single fam· y residents Demolition and grading S:: / / 7 / ?o23 Date FOROFFI FIRE DEPARTMENT OCCUPANCY CLASSIFICATION BY: DATE: I EXEMPT OR NO FURTHER INFORMATION REQUIRED RElEASfD FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO• APCD COUNTY-HMO APCD COUNTY-HMO APCD -.)'-'on Cor,t. §' 'o, q ~ Reviewed ~ -~~{!6/~~23 __ MF O<'ltt->/(l'Hll.tls -.S::J" ,, .~ Diego co . A stamp In thtS box ~ exempts busmesses from completing Of updating a Hazardous Matenals Business Plan. Other pennitting reqwremenlS may still apply HM-9171 (01/22) County of San Diego -DEH -Hazardous Materials DMslon EX/S1lli3S-VCP ~ SE'M:R WJN FfR _,,-I ""'""' LU s; :::i (..) :c:: <'.§~ <:( <:( 0¢~ I "I t "'"'1 " " w DEMOLITION NOTES [I EXISJ'JNG STRUCMIE TO 8E RHrlOVED (I; EX/SJ'JNG OFFS/TE Sll<IJCTURE' TO REMAIN I EX/STll/G TREE TO BE REMOVED :I EX/STl/lG FENCE TO BE RE.lf.'.JVED I f!(/SJ'JNGWAil TOBE REMOVED ]J EXISJ'JNGWALL TOREWJN II] EXISTINGIIARDSCAFf TOBE FIEM'.WEO [I) EXISTINGOVERHEADIJIJUTYTOBEREMOVED J V\Cffi/E J06SIJ58(J RJNCONACACJAICI\I/L=W/\13!GR.40'!,G PLANSl3580-CV-<,R!\0--02-lU1IO LW3 ~ .-::~ ~.; < ~ ,rill // " 1747 Cof'J~7-1011&1 f wkfH ')"f/>rl Io rJ WT1D =•w v9. , ... , _,;ii, ~ ; ./_-(,] - Afflzr>,1.240-W-00 '..-(' it1M' f C£I N7"f', ~u,iJC, IJ.l/ ,ew.i 4 #al£-t-t,o-ril Af¥12{)4.24M7-W l./3.fW15"W;..;;'"sw;;_ __ _ / t-" I N~!WW15000' I I I I ~ r-" I I I LOT2 Alo\P!747 APN 2/U.24!J.1/J.00 I ~ ½ll ,- PLAN VIEW-DEMO PLAN SOil£ 1"=10'f-/CRj[OlflA/. SITE NOTES r Ail um.mES SHCWNH€FIEONPERBEST AVAILABLE RECORD~ORW,DON, WTH EXCEPTIOO OF SE\tER IJIJLJTlES CONTRACTOR TO F/Ell) \IERJFY smrn IJlJ/JTIES 2 A.LL EXISTI/l, ONSITF. STROCTI.RES TO BE DfMOUSHED U/'l.ESS OJHERl'l!SE NOTED 3 Ail EX/STlM; ON!SiTF. /REES TO BE REMO\IED I.KESS OTIEffWISE NOTED LOT:J M4P 1141 .f AilONS/lE W!llfll SE'MR ANOSTORMDRA/NF'ACIUDES TOBE PRNATELYI.WNTAJNED 5 Ht.RDSCAPf Slv.t.L rw,m AWAY F'ROM PROPOSl:.D Sll<UCTIJRES AT MIIIMUII OF 2 o,; FOR IOFEET.AND~ FORA II/JIIMUMOF5o,t,/NACCORDAIK:f. WTH THE 2016 CAUFORMA BtAU/11,GGOa SECITOI'/ 18/')44 AM'Df\llAOONSJi,lil /IEQl.!/RE IIECCJMlll'/a!T/0,/ rROM l'RO.£CT GEOTECHNCAL ENGINEER I I I I I I I I I I I ~7 ~ 1'tt1CoH POR LOTIO ~=, M'\P/803 Affl20.f.U().t,2-(X) r Ho~._1 REC£fV£D 1 1~ 11PR 2 (j 2023 -I'. _ c,r, .DF CARtseAn r ::.:.I -T ---l3u!LDING D!VJS,oN --I APN 20.f.)4/J.11-00 I I I I LOT4 MAP 1141 APN 20.f.24/J.12,l)J ~ GRAPl-ilCSCALE 1·=1/l .,. ___ , " '" w • "AS BUILT" PASCO LARET SUITER "'---'"---- -----&ASSOCIATES San Diego I Soh~~ Q~,-'-' ~-----r----• REVIEWED BY Phone 858 259 ~ CBRA2023-0051 245 ACACIA AVE I DATE DEMOLITION OF (2) EXISTING SMALL HOMES (11,250 SF) DAtt J N'nAL ENGINEEI 0f wtlflC REVISION DESCRIPTION "~ ,,,., . 2042400800 4/26/2023 CBRA2023-0051