Loading...
HomeMy WebLinkAbout2814 CAZADERO DR; ; CBRA2018-0149; PermitBuilding Permit Finaled (city of Carlsbad Residential Associated Permit Print Date: 08/23/2023 Job Address: 2814 CAZADERO DR, CARLSBAD, Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: Valuation: 2153203600 $454,936.62 Occupancy Group: #of Dwelling Units: 1 Track#: Lot#: Project#: Plan#: Condo DEV2017-0134 Bedrooms: 4 Construction Type: Bathrooms: 4.0 Occupant Load: Orig. Plan Check#: PC2018-0027 Plan Check#: Code Edition: Sprinkled: Project Title: CAZADERO DR CONDO PROJECT Description: CAZADERO CONDO PROJECT: 2,785 SF CONDO/ 600 SF GARAGE/ 299 SF DECK Applicant: CHRISTOPHER SAWAYA 3636 5TH AVE, # 106 SAN DIEGO, CA 92103-4220 (619) 916-8145 FEE Property Owner: CAZADERO PROPERTIES LLC 401 B ST, # 2400 SAN DIEGO, CA 92101 (619) 795-8593 BRIDGE & THOROUGHFARE District 1 -Condominium BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION LOCAL FACILITIES MANAGEMENT ZONE (LFMZ) -ZONE 6 MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM TRAFFIC IMPACT Residential Condo Outside CFO Total Fees: $23,813.55 Total Payments To Date: Building Division $23,813.55 Permit No: Status: CBRA2018-0149 Closed -Finaled Applied: 06/14/2018 Issued: 01/24/2020 Finaled Close Out: 08/23/2023 Final Inspection: 08/21/2023 INSPECTOR: Kersch, Tim Balance Due: Alvarado, Tony Renfro, Chris AMOUNT $424.00 $1,886.25 $1,320.38 $66.00 $175.00 $310.00 $92.00 $182.00 $15,922.78 $19.00 $59.14 $246.00 $55.00 $3,056.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov PERMIT INSPECTION HISTORY for (CBRA2018-0149) Permit Type: BLDG-Associated Permit Residenti, Work Class: Condo Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Issue Date: 01/24/2020 Status: Closed -Finaled Expiration Date: 07/10/2023 IVR Number: 11973 Subdivision: Address: 2814 CAZADERO DR CARLSBAD, Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 07/22/2022 11/15/2022 01/11/2023 08/21/2023 Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS 07/22/2022 BLDG-82 Drywall, Exterior Lath, Gas Test, Hot Mop 187420-2022 Checklist Item BLDG-Building Deficiency BLDG-17 Interior Lath-Drywall BLDG-18 Exterior Lath and Drywall BLDG-23 Gas-Test-Repairs COMMENTS 11/15/2022 BLDG-66 Grout Checklist Item 196524-2022 COMMENTS Passed Chris Renfro Cancelled Chris Renfro BLDG-Building Deficiency Cancelled wrong department, CMI inspection requested for side privacy walls 01/11/2023 BLDG-25 Water HeaterNents Checklist Item 200460-2023 Partial Pass Chris Renfro COMMENTS BLDG-Building Deficiency Not ready. Will reinspect at final inspection BLDG-33 Service Change/Upgrade Checklist Item 200462-2023 COMMENTS BLDG-Building Deficiency BLDG-43 Air Cond./Furnace Set Checklist Item 200461-2023 COMMENTS Passed Chris Renfro Partial Pass Chris Renfro BLDG-Building Deficiency Not ready. Will reinspect at final inspection 08/21/2023 BLDG-Final Inspection Checklist Item 221511-2023 COMMENTS BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Passed Chris Renfro Wednesday, August 23, 2023 Passed Yes Yes Yes Yes Yes Complete Passed Yes Yes Yes Yes Reinspection Incomplete Passed No Reinspection Incomplete Passed No Complete Passed Yes Reinspection Incomplete Passed No Complete Passed Yes Yes Yes Yes Yes Page 6 of7 Permit Type: Work Class: Status: Scheduled Date 02/14/2022 06/02/2022 PERMIT INSPECTION HISTORY for (CBRA2018-0149) BLDG-Associated Permit Residenti; Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Condo Issue Date: 01/24/2020 Subdivision: Closed -Finaled Expiration Date: 07/10/2023 Address: 2814 CAZADERO DR 11973 CARLSBAD, Actual Start Date IVR Number: Inspection Type Inspection No. Inspection Primary Inspector BLDG-31 Underground-Conduit Wiring Status April 9, 2021: 1. No building slab/foundation footing Deficiencies. 2. Exterior and interior new dwelling footprint, isolated footing and continuous footing foundation details, and multiple pad foundation footings, scope of steel reinforcement and footing depth and width, per structural engineers plans and detail specifications of new 5" concrete slab and foundation steel reinforcement work-approved. 3. Verified third-party special/deputy Inspector report and file in city records. 4. Verified soil's/geotechnical engineer's path certification report and filed in city records. 5. Underground waste and vent plumbing lines wrapped and protected-approved. 6. Underground electrical conduit correct pipe and installed correctly, Ufer ground Verified-Approved. *** pending**** 7. Height certification verification form-required per civil or surveyor. Informed contractor superintendent. 9. Set backs to property line certification verification form required by civil or surveyor. Informed contractor superintendent. 10. Rest of work-OK to pour concrete. 02/14/2022 BLDG-23 176589-2022 Partial Pass Chris Renfro Gas/Test/Repairs Checklist Item COMMENTS BLDG-Building Deficiency BLDG-44 Rough/Ducts/Dampers Checklist Item 176590-2022 COMMENTS BLDG-Building Deficiency 06/02/2022 BLDG-84 Rough Combo(14,24,34,44) 183967-2022 Partial Pass Chris Renfro Passed Chris Renfro Reinspection Inspection Yes Reinspection Incomplete Passed Yes Reinspection Incomplete Passed Yes Complete Wednesday, August 23, 2023 Page 5 of7 PERMIT INSPECTION HISTORY for (CBRA2018-0149) Permit Type: BLDG-Associated Permit Residenti, Work Class: Condo Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date BLDG-21 Underground-Undertloor Plumbing Wednesday, August 23, 2023 Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Issue Date: 01/24/2020 Expiration Date: 07/10/2023 IVR Number: 11973 Subdivision: Address: 2814 CAZADERO DR CARLSBAD, Inspection No. Inspection Status Primary Inspector Reinspection Inspection April 9, 2021: 1. No building slab/foundation footing Deficiencies. 2. Exterior and interior new dwelling footprint, isolated footing and continuous footing foundation details, and multiple pad foundation footings, scope of steel reinforcement and footing depth and width, per structural engineers plans and detail specifications of new 5" concrete slab and foundation steel reinforcement work-approved. 3. Verified th·1rd-party special/deputy inspector report and file in city records. 4. Verified soil's/geotechnical engineer's path certification report and filed in city records. 5. Underground waste and vent plumbing lines wrapped and protected-approved. 6. Underground electrical conduit correct pipe and installed correctly, Ufer ground Verified-Approved. '** pending**** 7. Height certification verification form-required per civil or surveyor. Informed contractor superintendent. 9. Set backs to property line certification verification form required by civil or surveyor. Informed contractor superintendent. 1 O. Rest of work-OK to pour concrete. Yes Page 4 of? PERMIT INSPECTION HISTORY for (CBRA2018-0149) Permit Type: BLDG-Associated Permit Residenti: Work Class: Condo Status: Closed -Finaled Application Date: 06/14/2018 Issue Date: 01/24/2020 Expiration Date: 07/10/2023 IVR Number: 11973 Owner: CAZADERO PROPERTIES LLC Subdivision: Address: 2814 CAZADERO DR CARLSBAD, Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection BLDG-12 Steel-Bond Beam Wednesday, August 23, 2023 April 9, 2021: 1. No building slab/foundation footing Deficiencies. 2. Exterior and interior new dwelling footprint, isolated footing and continuous footing foundation details, and multiple pad foundation footings, scope of steel reinforcement and footing depth and width, per structural engineers plans and detail specifications of new 5" concrete slab and foundation steel reinforcement work-approved. 3. Verified third-party special/deputy inspector report and file in city records. 4. Verified soil's/geotechnical engineer's path certification report and filed in city records. 5. Underground waste and vent plumbing lines wrapped and protected-approved. 6. Underground electrical conduit correct pipe and installed correctly, Lifer ground Verified-Approved. *** pending**** 7. Height certification verification form-required per civil or surveyor. Informed contractor superintendent. 9. Set backs to property line certification verification form required by civil or surveyor. Informed contractor superintendent. 10. Rest of work-OK to pour concrete. Yes Page 3 of7 Permit Type: Work Class: Status: Scheduled Date PERMIT INSPECTION HISTORY for (CBRA2018-0149) BLDG-Associated Permit Residenti, Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Condo Issue Date: 01/24/2020 Subdivision: Closed -Finaled Expiration Date: 07/10/2023 Address: 2814 CAZADERO DR IVR Number: 11973 CARLSBAD, Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item COMMENTS BLDG-11 Foundation-Fig-Piers April 9, 2021: (Rebar) 1. No building slab/foundation footing Deficiencies. 2. Exterior and interior new dwelling footprint, isolated footing and continuous footing foundation details, and multiple pad foundation footings, scope of steel reinforcement and footing depth and width, per structural engineers plans and detail specifications of new 5" concrete slab and foundation steel reinforcement work-approved. 3. Verified third-party special/deputy inspector report and file in city records. 4. Verified soil's/geotechnical engineer's path certification report and filed in city records. 5. Underground waste and vent plumbing lines wrapped and protected-approved. 6. Underground electrical conduit correct pipe and installed correctly, Ufer ground Verified-Approved. *** pending**** 7. Height certification verification form-required per civil or surveyor. Informed contractor superintendent. 9. Set backs to property line certification verification form required by civil or surveyor. Informed contractor superintendent. 10. Rest of work-OK to pour concrete. Passed Yes Wednesday,August23,2023 Page 2 of 7 Building Permit Inspection History Finaled (city of Carlsbad PERMIT INSPECTION HISTORY for (CBRA2018-0149) Permit Type: BLDG-Associated Permit Residenti, Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Work Class: Condo Issue Date: 01/24/2020 Subdivision: Status: Closed -Finaled Expiration Date: 07/10/2023 Address: 2814 CAZADERO DR IVR Number: 11973 CARLSBAD, Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection Date Start Date Status 09/22/2020 09/22/2020 BLDG-SW-Pre-Con 138882-2020 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/10/2021 03110/2021 BLDG-21 152435-2021 Passed Tim Kersch Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency L Yes K' 04/09/2021 0410912021 BLDG-81 Underground 154621-2021 Partial Pass Tony Alvarado Reinspection Incomplete Combo(11, 12,21,31) Wednesday,August23,2023 Page 1 of7 ' .. • ' • .-;-i·t ;t , ,-\r;. ;,,}, )A-'~< ,-,9,Ji.\ 'A ·.,:/·;i .. • •• ;'f< Eagle Special Inspections, Inc Job Ad<lcess 2812 Cazadero Dr Job Name Cazadero Condos Architect Contractor KM Services -Material Nailing Description ---·-·- ACI-ICC PO Box 2276, Vista, CA 92085 (760) 716-0244 Email: mike@eagleinsp.com DAILY OBSERVATION REPORT --· Permit No. PC2018.-0027 Plan File No. Engineer Prentice Subcontractor Samples " X ·-·-·· ·---- Issued by Carlsbad ·- " Qty ----------·--· --- DESCRIPTION OF WORK OBSERVED DATE:07/16/2021 ----------,----------------------·-----·------· ---,- Observation of shear nailing for walls with 4" o.c. nailing and tighter. Nailing is in place per the shear wall schedule and S2.0 & S2.1 callouts. Nails driven flush and staggered. Anchor bolts, hold downs and A35/L TP4 in place as scheduled. Noted approved change to shear walls on the north and south walls where additional window was added. I hereby certify, that at the time of this report, I have observed all of the Inspector Michael DuTemple above reported work, unless otherwise noted. To the best of my knowledge ~ -- and belie!~ I have found this work to comply with the approved plans, specifications and applicable sections of the building code as ii applies to Signature the jurisdiclion where the project is located. This report cannot be ·---construed to be a recommendation of work. of any nature, to be perfonncd. -The Owner. or a successor in interest . .sh,'l!I hold harmless Eagle Special Nailing SD 824 / ICC 8206178 lnspeclions, Inc from any and all leg.al proceedings, of any nature whatsoever. that arc related to the observation service::; provided. ·--·--Specialty License No. - TIME IN TIMEOUT MIN FEE DAILY FEE OT !IRS OT HRS 4 Approved lly: --L--. ·-----'-------· CE &S CHRISTENSEN ENGINEERING &SURVEYING April 26, 2021 Ron Hiebert Cypress View Builders Inc. 40 I B Street, Suite 2400 San Diego, CA 92101 A DD :gf;@S': 'P!-~ t:I:: I ;2.-& l 2-C,,..z.,.-reRD W CS.~k :ZO I B -0 I 4-~ ,z.e, l4-C.A-ZI\'~ ~ GB M 7.?lf;-t1 14-9 1 7888 SILVERTON A VENUE, SUITE J SAN DIEGO, CALIFORNIA 92126 (858) 271-9901 PHONE Via Email: ron@cypressview.com Subject: Concrete Foundation Verification/or 2812 and 2814 Cazadero, Carlsbad Dear Ron: On April 15, 2021 Christensen Engineering & Surveying visited the above referenced site and measured the top corners of the concrete foundation. The foundation was found to exist horizontally and vertically per the approved construction drawings. Horizontally, the foundations will conform with the setbacks as shown on the approved drawings. Vertically, the top of the foundation will allow for the structure to be framed and not exceed the height limitation. Please feel free to contact me if you have any questions or wish to discuss this matter. Patrick F. Christensen, PLS for Christensen Engineering & Surveying ceands@aol.com JN 2016-17 I) LAND ,. CHR1 "' v> .. <l.. ,.., rxp 0J.J1-2.z."' ~ CIVIL ENGINEERING• LAND SURVEYING• LAND PLAN!'IING • FORENSIC E~GJNEERL~G (City of Carlsbad This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit. The City will not issue any building permit without a completed school fee form. Project No. & Name: DEV2017-0134, CAZADERO DR CONDO PROJECT Plan Check No.: Project Address: Assessor's Parcel No.: Project Applicant: (Owner Name) Residential Square Feet: CBRA2018-0149 2814 CAZADERO DR 2153203600 JAN 1 7 2020 CAZADERO CONDO PROJECT , New/Additions: 2,785 SF CONDO/ 600 SF GARAGE/ 299 SF DECK Second Dwelling Unit: Commercial Square Feet: New/Additions: City Certification: City of Carlsbad Building Division Date: 06/14/2018 Certification of ApplicanUOwners. The person executing this declaration ("Owner") certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect. and that (2) the Owner is the owner/developer of the above described project(s), or that the person executing this declaration is authorized to sign on behalf of the Owner. [l/i:;Jil Carlsbad Unified School District 6225 El Camino Real Carlsbad CA 92009 Phone: (760) 331-5000 1::<:J,':] Encinitas Union School District 101 South Rancho Santa Fe Rd Encinitas, CA 92024 Phone: (760) 944-4300 x1166 f'.:;i:'.;:::J San Dieguito Union H.S. District 684 Requeza Dr. Encinitas, CA 92024 Phone: (760) 753-6491 Ext 5514 (By Appt. Only) f;:;.Jtl San Marcos Unified Sch. District 255 Pico Ave Ste. 100 San Marcos, CA 92069 Phone (760) 290-2649 Contact: Katherine Marcelja (By Appl.only) [;<;:;::t Vista Unified School District 1234 Arcadia Drive Vista CA 92083 Phone: (760) 726-2170 x2222 SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school district(s)} THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District. The City may issue building pe,mits to, this p,oject. il : . 1 \ r S•M'"• o< At,~•• S<>oo, )''""°'"'"_ c ~~IL\¥") Title: ___ J_\d,J_)1,.L1,c---~{., ':, l ___________ Date: Name of School District: Building Division 1635 Faraday Avenue ; Carlsbad, CA 92008 I 760-602-2719 I 760-602-8S58 fax I building@carlsbadca.gov JAN 1 7 2020 \._ City of Carlsbad [{] Leucadia Wastewater District 1960 La Costa Ave. Carlsbad, CA 92009 (760) 753-0155 D Vallecitos Water District 201 Vallecitos de Oro San Marcos, CA 92069 (760) 744-0460 The following project has been submitted for building permits: Plan Check #: PC2018-0027 Permit #: CBRA2018-0149 Property Owner: CAZADERO PROPERTIES LLC Project Address: 2814 CAZADERO DR Assessor's Parcel#: 2153203600 Project Description: CAZADERO CONDO PROJECT: 2,785 SF CONDO/ 600 SF GARAGE/ 299 SF DECK City Certification: City of Carlsbad Building Division Date: December 19, 2019 Please indicate in the space below that the owner has entered into an agreement to have your agency provide public sewer service to the premises, and/or if the existing service is adequate for this project and all required conditions have been satisfied. Permits will not be issued until this form is completed and returned to our office. This space to be completed by District Personnel I certify the district requirements for sewer service have been satisfied. Approved by: ~ ~ __ j:~:~-P Title: HELD SERVICES SPECIALIST Community & Economic Development -Building Division 1635 Faraday Avenue, Carlsbad, CA 92008-7314 760-602-2700 760-602-8560 f ; www carlsbadca.gov