Loading...
HomeMy WebLinkAbout2812 CAZADERO DR; ; CBRA2028-0148; PermitBuilding Permit Finaled (city of Carlsbad Residential Associated Permit Print Date: 08/23/2023 Job Address: Permit Type: Parcel#: Valuation: 2812 CAZADERO DR, CARLSBAD, BLDG-Associated Permit Residential 2153203600 $454,936.62 Occupancy Group: #of Dwelling Units: 1 Work Class: Condo Track#: Lot#: Project#: DEV2017-0134 Plan#: Bedrooms: 4 Construction Type: Bathrooms: 4.0 Occupant Load: Orig. Plan Check#: PC2018-0027 Plan Check#: Code Edition: Sprinkled: Project Title: CAZADERO DR CONDO PROJECT Description: CAZADERO CONDO PROJECT: 2,785 SF CONDO/ 600 SF GARAGE/ 299 SF DECK Applicant: CHRISTOPHER SAWAYA 3636 5TH AVE, # 106 SAN DIEGO, CA 92103-4220 (619) 916-8145 FEE Property Owner: CAZADERO PROPERTIES LLC 401 B ST, # 2400 SAN DIEGO, CA 92101 (619) 795-8593 BRIDGE & THOROUGHFARE District 1-Condominium BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION LOCAL FACILITIES MANAGEMENT ZONE (LFMZ) -ZONE 6 MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFO SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM TRAFFIC IMPACT Residential Condo Outside CFO Total Fees: $23,813.55 Total Payments To Date: Building Division $23,813.55 Permit No: Status: CBRA2018-0148 Closed -Finaled Applied: 06/14/2018 Issued: 01/24/2020 Finaled Close Out: 08/23/2023 Final Inspection: 08/21/2023 INSPECTOR: Kersch, Tim Balance Due: Alvarado, Tony Renfro, Chris Burnette, Paul AMOUNT $424.00 $1,886.25 $1,320.38 $66.00 $175.00 $310.00 $92.00 $182.00 $15,922.78 $19.00 $59.14 $246.00 $55.00 $3,056.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov PERMIT INSPECTION HISTORY for {CBRA2018·0148) Permit Type: BLDG-Associated Permit Residenti, Work Class: Condo Status: Closed -Finaled Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Issue Date: 01/24/2020 Subdivision: Expiration Date: 08/21/2023 Address: 2812 CAZADERO DR IVR Number: 11969 CARLSBAD, Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Wednesday, August 23, 2023 Checklist Item BLDG-Bui/ding Deficiency BLDG-Plumbing Fina) BLDG-Mechanical Fina! BLDG-Structural Final BLDG-Electrical Final COMMENTS Status Passed Yes Yes Yes Yes Yes Page 8 of 8 PERMIT INSPECTION HISTORY for {CBRA2018-0148) Permit Type: BLDG-Associated Permit Residenti, Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Work Class: Condo Issue Date: 01/24/2020 Subdivision: Status: Closed -Finaled Expiration Date: 08/21/2023 Address: 2812 CAZADERO DR IVR Number: 11969 CARLSBAD, Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-23 187422-2022 Passed Chris Renfro Complete GasfTest/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 11/15/2022 11/1512022 BLDG-66 Grout 196525-2022 Cancelled Chris Renfro Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Cancelled wrong department, CMI No inspection requested for side privacy walls 01/11/2023 01/11/2023 BLDG-25 Water 200457-2023 Partial Pass Chris Renfro Re inspection Incomplete HeaterNents Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready. Wi\\ reinspect at final inspection No BLOG-33 Service 200459-2023 Passed Chris Renfro Complete Change/Upgrade Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-43 Air 200458-2023 Partial Pass Chris Renfro Re inspection Incomplete Cond./Furnace Set Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready. Will reinspect at final inspection No 02/0912023 02/09/2023 BLOG-66 Grout 202904-2023 Passed Tim Kersch Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Cancelled wrong department, CMl Yes inspection requested for side privacy walls NOTES Created By TEXT Created Date Angie Teanio 619-840-2022 Ron 02/0812023 02/21/2023 02/21/2023 BLDG-71 Set Ups 203710-2023 Passed Tim Kersch Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 08/21/2023 08/21/2023 BLDG-Final Inspection 221510-2023 Passed Chris Renfro Complete Wednesday,August23,2023 Page 7 of 8 PERMIT INSPECTION HISTORY for (CBRA2018-0148) Permit Type: BLDG-Associated Permit Residenti, Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Work Class: Condo Issue Date: 01/24/2020 Subdivision: Status: Closed -Finaled Expiration Date: 08/21/2023 Address: 2812 CAZADERO DR IVR Number: 11969 CARLSBAD, Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deflc'iency July 19, 2021: Yes 1. Shearwall method of attachments: a) type, size, fasteners schedule, and metal connector hardware, per structural plans S-1 and S-2, per structural engineers plans and detail specifications tables-approved. 2. Roof fastening schedule: a) type, size, and nailing schedule per structural engineers plans and detail specifications-approved. 02/14/2022 02/14/2022 BLDG-23 176587-2022 Partial Pass Chris Renfro Reinspection Incomplete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-44 176588-2022 Partial Pass Chris Renfro Reinspection Incomplete Rough/Ducts/Dampers Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/02/2022 06/02/2022 BLDG-84 Rough 183966-2022 Passed Chris Renfro Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 07/14/2022 07/14/2022 BLDG-17 Interior 186993-2022 Passed Chris Renfro Complete Lath!Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-23 186863-2022 Failed Chris Renfro Reinspection Incomplete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 07/22/2022 07/22/2022 BLDG-18 Exterior 187421-2022 Passed Chris Renfro Complete Lath/Drywall Wednesday, August 23, 2023 Page 6 ofB PERMIT INSPECTION HISTORY for (CBRA2018-0148) Permit Type: BLDG-Associated Permit Residenti, Work Class: Condo Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Status: Closed -Finaled Issue Date: 01/24/2020 Expiration Date: 08/21/2023 IVR Number: 11969 Subdivision: Address: 2812 CAZADERO DR CARLSBAD, Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 07/19/2021 BLDG-31 Underground-Conduit Wiring April 1, 2021: 1. No building slab/foundation footing Deficiencies. 2. Exterior and interior new dwelling footprint, isolated footing and continuous footing foundation details, and multiple pad foundation footings, scope of steel reinforcement and footing depth and width, per structural engineers plans and detail specifications of new 5" concrete slab and foundation steel reinforcement work-approved. 3. Verified third-party special/deputy inspector report and file in city records. 4. Verified soil's/geotechnical engineer's path certification report and filed in city records. 5. Underground waste and vent plumbing lines wrapped and protected-approved. 6. Underground electrical conduit correct pipe and installed correctly, Ufer ground Verified-Approved. *** pending**** 7. Height certification verification form-required per civil or surveyor. Informed contractor superintendent. 9. Set backs to property line certification verification form required by civil or surveyor. Informed contractor superintendent. 10. Rest of work-OK to pour concrete. 07/19/2021 BLDG-13 Shear Panels/HD (ok to wrap) 162187-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS July 19, 2021: 1. Shearwall method of attachments: a) type, size, fasteners schedule, and metal connector hardware, per structural plans S-1 and S-2, per structural engineers plans and detail specifications tables-approved. 2. Roof fastening schedule: a) type, size, and nailing schedule per structural engineers plans and detail specifications-approved . BLDG-15 Roof/ReRoof (Patio) 162188-2021 Passed Tony Alvarado Wednesday, August 23, 2023 Yes Complete Passed Yes Complete Page 5 of 8 PERMIT INSPECTION HISTORY for {CBRA2018-0148) Permit Type: BLDG-Associated Permit Residenti, Work Class: Condo Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date BLDG-21 Underground-Underfloor Plumbing Wednesday,August23,2023 Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Issue Date: 01/24/2020 Expiration Date: 08/21/2023 IVR Number: 11969 Subdivision: Address: 2812 CAZADERO DR CARLSBAD, Inspection No. Inspection Status Primary Inspector Reinspection Inspection April 1, 2021: 1. No building slab/foundation footing Deficiencies. 2. Exterior and interior new dwelling footprint, isolated footing and continuous footing foundation details, and multiple pad foundation footings, scope of steel reinforcement and footing depth and width, per structural engineers plans and detail specifications of new 5" concrete slab and foundation steel reinforcement work-approved. 3. Verified third-party special/deputy inspector report and file in city records. 4. Verified soil's/geotechnica/ engineer's path certification report and fifed in city records. 5. Underground waste and vent plumbing lines wrapped and protected-approved. 6. Underground electrical conduit correct pipe and installed correctly, Ufer ground Verified-Approved. *** pending**** 7. Height certification verification form-required per civil or surveyor. Informed contractor superintendent. 9. Set backs to property line certification verification form required by civil or surveyor. Informed contractor superintendent. 10. Rest of work-OK to pour concrete. Yes Page 4 of 8 Permit Type: Work Class: Status: Scheduled Date PERMIT INSPECTION HISTORY for (CBRA2018-0148) BLDG-Associated Permit Residenti, Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Condo Issue Date: 01/24/2020 Subdivision: Closed -Finaled Expiration Date: 08/21/2023 Address: 2812 CAZADERO DR IVR Number: 11969 CARLSBAD, Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Start Date BLOG-12 Steel-Bond Beam Status April 1, 2021: 1. No building slab/foundation footing Deficiencies. 2. Exterior and interior new dwelling footprint, isolated footing and continuous footing foundation details, and multiple pad foundation footings, scope of steel reinforcement and footing depth and width, per structural engineers plans and detail specifications of new 5" concrete slab and foundation steel reinforcement work-approved. 3. Verified third-party special/deputy inspector report and file in city records. 4. Verified soil's/geotechnica\ engineer's path certification report and filed in city records. 5. Underground waste and vent plumbing lines wrapped and protected-approved. 6. Underground electrical conduit correct pipe and installed correctly, Lifer ground Verified-Approved. *** pending**** 7. Height certification verification form-required per civil or surveyor. Informed contractor superintendent. 9. Set backs to property line certification verification form required by civil or surveyor. Informed contractor superintendent. 10. Rest of work-OK to pour concrete. Yes Inspection Wednesday, August 23, 2023 Page 3 of8 PERMIT INSPECTION HISTORY for (CBRA2O18-0148) Permit Type: BLDG-Associated Permit Residenti, Work Class: Condo Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Status: Scheduled Date Issue Date: 01/24/2020 Subdivision: Closed -Finaled Expiration Date: 08/21/2023 IVR Number: 11969 Address: 2812 CAZADERO DR CARLSBAD, Actual Inspection Type Start Date Checklist Item Inspection No. COMMENTS Inspection Status Primary Inspector BLDG-11 Foundation-Ftg-Piers April 1, 2021 • (Rebar) 1. No building slab/foundation footing Deficiencies. 2. Exterior and interior new dwelling footprint, isolated footing and continuous footing foundation details, and multiple pad foundation footings, scope of steel reinforcement and footing depth and width, per structural engineers plans and detail specifications of new 5" concrete slab and foundation steel reinforcement work-approved. 3. Verified third-party special/deputy inspector report and file in city records. 4. Verified soiJ's/geotechnical engineer's path certification report and filed in city records. 5. Underground waste and vent plumbing lines wrapped and protected-approved. 6. Underground electrical conduit correct pipe and installed correctly, Ufer ground Verified-Approved. *** pending**** 7. Height certification verification form-required per civil or surveyor. Informed contractor superintendent. 9. Set backs to property line certification verification form required by civil or surveyor. Informed contractor superintendent. 1 O. Rest of work-OK to pour concrete. Reinspection Inspection Passed Yes Wednesday, August 23, 2023 Page2 of8 Building Permit Inspection History Finaled (City of Carlsbad PERMIT INSPECTION HISTORY for (CBRA2O18-0148} Permit Type: BLDG-Associated Permit Residenti, Application Date: 06/14/2018 Owner: CAZADERO PROPERTIES LLC Work Class: Condo Issue Date: 01/24/2020 Subdivision: Status: Closed -Finaled Expiration Date: 08/21/2023 Address: 2812 CAZADERO DR IVR Number: 11969 CARLSBAD, Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 09/22/2020 09/22/2020 BLDG-SW-Pre-Con 138881-2020 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 12/04/2020 12/04/2020 BLDG-32 Const. 145426-2020 Passed Paul Burnette Complete Service/Agricultural(Te mp) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/10/2021 03/10/2021 BLDG-21 152434-2021 Passed Tim Kersch Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/09/2021 04/09/2021 BLDG-81 Underground 154620-2021 Partial Pass Tony Alvarado Reinspection Incomplete Combo(11, 12,21,31) Wednesday,August23,2023 Page 1 of 8 Job Add,oss 2812 Cazadero Dr Eagle Special Inspections, Inc AC!-ICC PO Box 2276, Vista, CA 92085 (760) 7 I 6-0244 Email: mike@eagleinsp.com DAILY OBSERVATION REPORT "" --Pennit No. PC2018-0027 --------- Job Name Cazadero Condos Plan File No. Issued by Carlsbad Archltt:r.;t Engineer Prentice Contractor KM Services Subcontractor Material Nailing Samples " " Qty Description X ~ DESCRIPTION OF WORK OBSERVED DATE: 07/16/2021 -------------------------- Observation of shear nailing for walls with 4" o.c. nailing and tighter. Nailing is in place per the shear wall schedule and S2.0 & S2.1 callouts. Nails driven flush and staggered. Anchor bolts, hold downs and A35/L TP4 in place as scheduled. Noted approved change to shear walls on the north and south walls where additional window was added. I hereby certify, that at the time of this report, I have observed all of the above reported work, unless otherwise noted. To lhe best of my knowledge Inspector Michael DuTemple and belief, I have found this work to comply with the approved plans, ~ specifications and applicable sections of the building code as it applies to Signature the jurisdiction where the project is located. This report cannot be construed to be a recommendation of work, or any nature, to be performed. The Owner, or a successor in interest. shall hold harmless Eagle Special Nailing SD 824 / ICC 8206178 Inspections, Inc from any and all legal proceedinb~, ofany nature whatsoever, that arc related to the ob~crvation services provided. --Specialty License No. ·----·-·-· T!MEIN TIMEOUT MIN FEE DAILY FEE OT HRS DTHRS 4 Approved fly: . CE &S CHRISTENSEN ENGINEERING & SURVEYING April 26, 2021 Ron Hiebert Cypress View Builders Inc, 401 B Street, Suite 2400 San Diego, CA 92101 7888 SILVERTON A VENUE, SUITE J SAN DIEGO, CALIFORNIA 91116 (858) 2'11-9901 PHONE Via Email: ron@cypressview.com Subject: Concrete Foundation Verification for 2812 and 2814 Cazadero, Carlsbad Dear Ron: On April 15, 2021 Christensen Engineering & Surveying visited the above referenced site and measured the top corners of the concrete foundation. The foundation was found to exist horizontally and vertically per the approved construction drawings. Horizontally, the foundations will conform with the setbacks as shown on the approved drawings. Vertically, the top of the foundation will allow for the structure to be framed and not exceed the height limitation. Please feel free to contact me if you have any questions or wish to discuss this matter. Sincerely, ------ Patrick F. Christensen, PLS for Christensen Engineering & Surveying ceands@aol.com JN 2016-17 ~ ~ ~ -i< Exp 03-31-2.Z * . 1SJ11l'l:, ,,,_,..,_ F CAL\tll~ Cl\'IL EJ\GINEERil\"G • LAND SURVEYING• LAND PLAN';';'ING • FORE!\SIC E'.\'GINEERJNG ('city of Carlsbad CERT!IPICAff N OF SCHOOi. FEES PAID This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit. The City will not issue any building permit without a completed school fee form. Project No. & Name: DEV2017-0134, CAZADERO DR CONDO PROJECT Plan Check No.: CBRA2018-0148 Project Address: 2812 CAZADERO DR Assessor's Parcel No.: 2153203600 JAN 1 7 2020 ------------------- Project Applicant: ( Owner Name) CAZADERO CONDO PROJECT Residential Square Feet: New/Additions: 2,785 SF CONDO/ 600 SF GARAGE/ 299 SF DECK Second Dwelling Unit: Commercial Square Feet: New/Additions: City Certification: City of Carlsbad Building Division Date: 06/14/2018 Certification of Applicant/Owners. The person executing this declaration ("Owner") certifies under penalty of perjury that ( 1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or that the person executing this declaration is authorized to sign on behalf of the Owner. le: ;·j Carlsbad Unified School District 6225 El Camino Real Carlsbad CA 92009 Phone: (760) 331-5000 !':,;'',;,,:;j Encinitas Union School District 101 South Rancho Santa Fe Rd Encinitas, CA 92024 Phone: (760) 944-4300 x1166 l·E:,::'j San Dieguito Union H.S, District 684 Requeza Dr. Encinitas, CA 92024 Phone: (760) 753-6491 Ext 5514 (By Appl. Only) l::.::;•j San Marcos Unified Sch. District 255 Pico Ave Ste. 100 San Marcos, CA 92069 Phone: (760) 290-2649 Contact: Katherine Marcelja (By Appl.only) l ; J Vista Unified School District 1234 Arcadia Drive Vista CA 92083 Phone: (760) 726-2170 x2222 SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school district(s}) THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities, This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District. The City may issue building permits for this project. Title: _A DYi. N ---1-'-"~""-·c..._, .... 'o= __ '..------~------Date: I O I/ Lt I/~ Name of School District: Phone: }/j{j 2<J6 Z.{tjt:( Building Division 1635 Faraday Avenue I Carlsbad, CA 92008 I 760-602-2719 I 760-602-8558 fax I building@carlsbadca.gov [Z] Leucadia Wastewater District 1960 La Costa Ave. Carlsbad, CA 92009 (760) 753-0155 JAN 1 7 2020 \._ City of Carlsbad ovallecitos Water District 201 Vallecitos de Oro San Marcos, CA 92069 (760) 744-0460 The following project has been submitted for building permits: Plan Check #: PC2018-0027 Permit #: CBRA2018-0148 Property Owner: CAZADERO PROPERTIES LLC Project Address: 2812 CAZADERO DR Assessor's Parcel #: 2153203600 Project Description: CAZADERO CONDO PROJECT: 2,785 SF CONDO/ 600 SF GARAGE/ 299 SF DECK City Certification: City of Carlsbad Building Division Date: December 19, 2019 Please indicate in the space below that the owner has entered into an agreement to have your agency provide public sewer service to the premises, and/or if the existing service is adequate for this project and all required conditions have been satisfied. Permits will not be issued until this form is completed and returned to our office. This space to be completed by District Personnel I certify the district requirements for sewer service have been satisfied . . ) Approved by: ~-~'-J, • Title: FIELD SERVICES SPECIALIST Community & Economic Development -Building Division Date: 1635 Faraday Avenue, Carlsbad, CA 92008-7314 760-602-2700 i 760-602-8560 f ; www.carlsbadca.gov