HomeMy WebLinkAbout1982-08-25; Planning Commission; ; ZC 262|CT 82-15|CP-212 - DAON (ALICANTE HILLS CROSSROADS)•·
STAFF REPORT
DATE: August 25, 1982
TO: Planning Commission
FROM: Land Use Planning Office
APPLIC--'N SUBMITTAL DATE: ~ 24, 1982
SUBJECT: ZC-262/CT 82-15/CP-212, DAON (ALICANTE HILLS
CROSSROADS) -A Zone Change from R-1-10,000 to RD-Mand
a 40 lot, 490 unit Tentative Tract Map and Condominium
Permit, located on the south side of Corte De La Vista
(Alfil Way) east of Alicante Road in La Costa.
I. PROJECT DESCRIPTION
The applicant is requesting approval of:
1) A zone change from R-1-10,000 to RD-Mon a portion of
the site;
2) A 40 lot tentative tract map; and
3) A 490 unit condominium permit.
The site is located between Corte De La Vista (Alfil Way) and
the La Costa Golf Course east of Alicante Road. The property
contains 39.2 acres and the project's density would be 12.5
dwelling units per acre which is at the lower end of the General
Plan land use range of 10-20 du's/acre designated for this site.
The project would be built in four phases moving easterly from
Alicante Road. Three unit types are proposed; 324 hillside units
which will be constructed in four large building clusters along
the frontage of Corte De La Vista, 134 trails unit which will be
placed in four-plex structure running along the edge of the golf
course, and 32 split level units which will be located in the
middle of the project between the hillside and the trails unit.
The project will take access off of Alicante Road at one location
and off Corte De La Vista at six locations. Internal circulation
will be provided by a combination of private streets and
driveways. One of the private streets, Street "A", would provide
a continuous through access within the project from Alicante Road
to Corte De La Vista.
II. ANALYSIS
Planning Issues -ZC-262
1) Are the uses allowed in the requested zone
consistent with the General Plan and compatible with
surrounding land uses and zoning?
• • 2) Will the uses allowed in the requested zone
adversely impact traffic in this vicinity?
Discussion
Last year, the City Council approved a General Plan Amendment for
the subject property (GPA-58(I)) which changed the land use des-
ignation from RLM (0-4 du's/acre) to RMH (10-20 du's/acre). The
determination at that time was that Corte De La Vista should be
the dividing line between higher density development along the
golf course and lower density to the north. The requested RDM
zone would be consistent with this new designation. Also, a
portion of the property, 7 acres on the most westerly portion, is
already zoned RDM. Surrounding zoning consist of RDM to the west
and northwest, PC to the south and east and R-1-10,000 to the
north.
Staff's only concern with the zone change involved impacts on
traffic and circulation on the surrounding street system.
However, a traffic study was prepared which indicated that even
with the additional traffic generated by the project, surrounding
streets would still be substantially below maximum capacity
levels. The study did indicate that the signalization of
Alicante and Alga Roads may be warranted at the time the project
is completely built out.
In summary, staff believes that the zone change is consistent
with the General Plan and will be compatible with surrounding
zoning and that the required findings for approval of a zone
change can be made. Therefore, staff is recommending approval of
ZC-262.
Planning Issues -CT 82-15/CP-212
1) Visual impacts
2) Grading impacts
Discussion
As proposed, the project meets all of the development and design
standards of the Planned Development Ordinance for a condominium
project. Both private recreation facilities (balconies and
patios) and common recreational facilities will be provided. The
common area consists of three active recreation areas dispersed
throughout the project. These are well located with respect to
the units. Also, all parking, storage, setbacks and other
development standards are being met. The internal road system
has been designed to provide good circulation while still
allowing for some large areas for open space to break-up the
dominance of the street system.
Staff's primary concern, with respect to the design of the
project, involve visual impacts and offsite grading impacts. As
previously mentioned, the project consists of three unit types.
The hillside units are contained in four large building clusters
fronting on Corte De La Vista. Each building cluster will be
-2-
• • '·
stepped-up the hillside with three lower levels and three upper
levels. Parking will be provided in garages below the units on
the lower level and in a two-story parking deck in front of the
upper level off of Corte De La Vista. Although each building
cluster will be broken-up by stairways, they will appear from a
distance as one large massive building. In order to address this
concern, the applicant has offset the lower level (3 floors) and
the upper level (3 floors) by increasing the separation between
the levels and providing dense landscaping between the two
levels. Exhibits will be available at the meeting to demonstrate
the building separation and landscape treatment. Staff believes
that these measures have helped to break-up the massive
appearance of the hillside units to an acceptable level.
The only other staff concern involves the amount of dirt that
will have be exported from the site. The entire site has been
previously graded for individual lot development. In order to
make the site suitable for one consolidated project, a signif-
icant amount of cut grading will have to occur and be exported
off-site. Originally the applicant proposed 700,000+ cubic yards
of grading. Through redesign, this has been reduced-substan-
tially, however, 390,000 cubic yards must be exported off-site.
Approximately 80,000 cubic yards is proposed to be exported to
Alicante Hills (CT 81-29), an approved tentative map on the north
side of Corte De La Vista, and 310,000 cubic yards is proposed to
be exported to Alga Hills, 1400 feet to the northwest. The earth
moving operation would occur solely on Daon Corporation property
but would cross three public streets (See attached Exhibit 'O').
The disposal site is vacant and a portion of it has been pre-
viously graded to obtain the fill material that was placed on the
subject property. It is adjacent to an existing condominium
project, however, it was selected because it was previously dis-
turbed and it is located close to the subject property. This has
reduced the impacts of exporting this much dirt to a location a
greater distance from the property. Also, staff has recommended
a number of conditions which would help mitigate the impacts of
the off-site grading, operation. These are contained in the
environmental documents for the project and have also been incor-
porated into the conditions of approval.
With the mitigating measures being incorporated into the project
regarding visual and grading impacts, staff feels that the pro-
ject complies with the development standards and design criteria
of the Planned Development Ordinance and is, therefore,
recommending approval of the project.
III. ENVIRONMENTAL REVIEW
The Land Use Planning Manager has determined that based upon
mitigating measures being incorporated into the project, this
project will not have a significant effect upon the environment
and, therefore, a Conditional Negative Declaration was issued on
August 9, 1982.
-3-
• •
IV. RECOMMENDATION
It is recommended that the Planning Commission APPROVE the Con-
ditional Negative Declaration issued by the Land Use Planning
Manager and ADOPT Resolution Nos. 2013 and 2014, recommending
APPROVAL of ZC-262/CT 82-15/CP-212 to the City Council based on
the findings and subject to the conditions contained therein.
ATTACHMENTS
1 PC Resolution Nos. 2013 & 2014
2. Location Map
3. Background Data Sheet
4. Traffic Report from Weston Pringle and Associates, dated
June 23, 1982.
5. Disclosure Form
6. Environmental Documents
7. Exhibit "A" -"O", dated August 5, 1982
8. Exhibit "P", dated June 25, 1982
MJH/ar
8/13/82
-4-
•
BACKGROUND DATA SHEET
CASE NO: ZC-262/CT 82-15/CP-212
APPLICANT: DAON (ALICANTE HILLS)
•
REQUEST AND LOCATION: zone change from R-1-10,000 to RD-Mand a 40 lot/490
unit tentative tract map and condominium permit: s/s of Corte de la Vista
LEGAL DESCRIPTION: Parcel 2 of Parcel Map 11722 in the City of Carlsbad
according to Document No. 81-322184: October 9, 1981 APN:
Acres 39.2 Proposed No. of Lots/Units 40 lots/490 units
GENERAL PI.AN AND ZONING
Land Use Designation RMH ----------
Density Allowed 10-20 ----------Density Proposed 12. 5 du' s/Acre
Existing Zone R-1-10,000 Proposed Zone RDM ------------
Surrounding Zoning and Land Use:
Zoning
Site R-1-10,000 & RDM
Land Use
Vacant
North ROM -----
South O-S
Vacant -(approved condominium)
La Costa Golf Course -----
East P--C Vacant -----
West RDM Vacant -----
PUBLIC FACILITIES
Sewer Leucadia EDU's 490 ------School District San Marcos Water Carlsbad
Public Facilities Fee Agreement, dated ------------------
ENVIRONMEN'I'AL IMPACT ASSESSMENI'
X Negative Declaration, issued August 9, 1982 -=---~---------
E. I. R. Certified, dated --------------
Other, ---------------------------------