Loading...
HomeMy WebLinkAbout2382 FARADAY AVE; 140; CBC2023-0087; PermitBuilding Permit Finaled Commercial Permit Print Date: 09/27/2023 Job Address: 2382 FARADAY AVE, # 140, CARLSBAD, CA 92008-7219 Permit Type: Parcel#: Valuation: BLDG-Commercial 2120621800 $198,281.60 Occupancy Group: B #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: 40 Code Edition: 2022 Sprinkled: Yes Project Title: Work Class: Tenant Improvement Track#: Lot#: Project#: Plan#: Construction Type:VA Orig. Plan Check#: Plan Check#: Permit No: Status: ( City of Carlsbad CBC2023-0087 Closed -Finaled Applied: 04/05/2023 Issued: 07/06/2023 Finaled Close Out: 09/27/2023 Final Inspection: 09/26/2023 INSPECTOR: Salcedo, Felix Kersch, Tim Description: BREG: COM-Tl (3,440 SF) WITH (4) NEW LAB AREAS, CONFRENCE ROOM, MACHINE SHOP AND BREAK WORK ROOM Applicant: Property Owner: CEI OFFICE FUND 8 LLC MAGGETTI ELAM ASSOCIATES INC KRISTIE BERRILL 3160 CAMINO DEL RIO 5, # 207 SAN DIEGO, CA 92108-3834 (619) 624-0521 16870 W BERNARDO DR, # 360 SAN DIEGO, CA 92127 (714) 990-2100 FEE BUILDING PLAN CHECK FEE (manual) BUILDING PLAN REVIEW-MINOR PROJECTS (LDE) BUILDING PLAN REVIEW-MINOR PROJECTS (PLN) CERTIFICATE OF OCCUPANCY COMM/IND Tl -STRUCTURAL FIRE F Occupancies Tl FIRE Haz Mat Storage Chem Class <10 Chemicals 581473 -GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -COMMERCIAL (SMIP) Total Fees: $3,975.52 Total Payments To Date: $3,975.52 Balance Due: AMOUNT $922.22 $194.00 $98.00 $16.00 $1,418.80 $744.00 $574.00 $8.00 $0.50 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Pagelofl 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov I Plan Check e/3C. 2.02.3 • ooB 7 iQ·city of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Est Value ',:I. 75; f!'.S-:S, 6,0 PC Deposit .:I/ 'i'2 Z • ~~ Date 1 • $" • 'Z.()°23 Job Address 2382 Faraday Avenue Suite: 140 APN: 212-062-18-00 -----· Tenant Name #:_B_re-'g'--________________ Lot #: _____ Year Built: _1_98_6 ________ _ Year Built: 1986 0ccupancy:_B __ _ Construction Type:_V_A __ Fire sprinklers:@ESQNO A/C:OYESQNO BRIEF DESCRIPTION OF WORK: Tl to include new laboratory with (4) lab areas, conference room, machine shop and break/work room D Addition/New:. _____________ New SF and Use, __________ New SF and Use _______ SF Deck, _______ SF Patio Cover, SF Other (Specify) ____ _ [Z]Tenant Improvement: _____ SF, Existing Use: _______ Proposed Use: _______ _ _ 3_.4_4o ____ SF, Existing Use: Proposed Use: ______ _ D Pool/Spa: _____ SF Additional Gas or Electrical Features> _____________ _ D Solar: ___ KW, ____ Modules, Mounted: 0Roof 0Ground D Re roof: ______________________________________ _ D Plumbing/Mechanical/Electrical Oother: ______________________________________ _ APPLICANT (PRIMARY CONTACT) Name: Kristie Berrill Address· 3160 Camino Del Rio South, Ste. 207 PROPERTY OWNER Name: CEI Office Fund 8, LLC Address: 10920 Via Frontera, Suite 500 City· San Diego State:.CA Zip:_9_2_10_8 ___ City: San Diego State:_C_A __ .Zip: 92127 Phone· 619-624-0521 Phone: 858-587-7100 Email· kris@maggettielam.com Email: ____________________ _ DESIGN PROFESSIONAL CONTRACTOR OF RECORD Name· Maggetti Elam Associates, Inc, Business Name: BYCOR General Contractors Address: 3160 Camino Del Rio South, Suite 207 Address: 6490 Marindustry Place City· San Diego State: CA Zip: 92108 City: San Diego State: CA Zip:_9_2_12_1 ____ _ Phone: 619-624-0521 Phone: 858-587-1901 Email· kris@maggettielam.com Email: ____________________ _ Architect State License: _N_A ___________ CSLB License #:_4_44_2_0_3 _____ Class: B-General Construction Carlsbad Business License# (Required): ________ _ APPLICANT CERT/FICA T/ON: /certify that I have read the applicatianand state that the above information is correct and that the information on the plans is accurate. /agree to comply with all City ordinancesand State laws relating to building construction. ,} , 11 • I . AA NAME (PRINT): Kristie M. Berrill SIGN: ,{:)ti..:)(,.i::?L.1/-,DLU.--"l>ATE: 2/14/2023 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Fax: 760-602-8558 REV. 07/21 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I herebyaffi rm under penalty of perjury that I am I icensed under provisions of Chapter 9 (commencing with Section 7000) of Di vision 3 of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the following declarations (CHOOSE ONE): 01 have and will maintain a certificate of consent to self-·1nsure for workers' compensation provided by Section 3700 of the labor Code, for the performance of the work which this permit is issued. Policy No. _______________________________________ ~ -OR- (!]1 have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My workers' compensation ·insurance carrier and policy number are: Insurance Company Name: _N_a_"o_cw_,_d,_M_,_1,_a_11_cs_,_'°_"_°' _____________ _ Policy No. ACPWC311009ao21 Expiration Date: _,_11_12_, ______________ _ -OR- Ocertifrcate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ____________________ ~Lender's Address: _____________________ _ CONTRACTOR CERT/FICA T/ON: I certify that I have read the application and state that the above information is correct and that theinformationon the plans is accurate. /agree to comply withal/ City ordinances and State laws relating to building construction. NAME (PRINT): Kristie M. Berrill SIGNATURE:bMS,yvf.-.{ bJJ DATE: 2/14/2023 Note: If the person signing above is an authorized agent for the contractor provide a letter of authorization on contractor letterhead. • OR • (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: n I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. L...;d44, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or th rough his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- D1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who bu'ilds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR-□r am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: ...\.\D, D FORM B-61 "Owner Builder Acknowledgement and Verification Form" 1s required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the ·improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044of the Business and Professions Code, is available upon request when this application is submitted or at the following Web site: http:l lwww.leginfo.ca.govlcalaw.html. OWNER CERT/FICA T/ON: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. /agree to comply with all City ordinances and State laws relating to building construction. NAME (PRINT): DATE: -------------------SIGN: Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Fax: 760-602-8558 Email Bu1ld1ng@carlsbadca.gov 2 REV. 07/21 PERMIT INSPECTION HISTORY for (CBC2023-0087) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed -Finaled Application Date: 04/05/2023 Owner: CEI OFFICE FUND 8 LLC Issue Date: 07/06/2023 Subdivision: PARCEL MAP NO 16317 Expiration Date: 02/05/2024 IVR Number: 48020 Address: 2382 FARADAY AVE, # 140 CARLSBAD, CA 92008-7219 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection 09/19/2023 09/19/2023 09/26/2023 09/26/2023 Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS BLDG-Fire Final 215662-2023 Checklist Item COMMENTS FIRE-Building Final BLDG-Final Inspection 224485-2023 Checklist Item COMMENTS BLOG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Wednesday, September 27, 2023 Status Passed Felix Salcedo Passed Tim Kersch Passed Yes Yes Yes Yes Yes Passed Yes Passed Yes Yes Yes Yes Yes Complete Complete Page 2 of 2 Building Permit Inspection History Finaled (city of Carlsbad PERMIT INSPECTION HISTORY for (CBC2023-0087) Permit Type: BLDG-Commercial Application Date: 04/05/2023 Owner: CEI OFFICE FUND 8 LLC Work Class: Tenant Improvement Issue Date: 07/06/2023 Subdivision: PARCEL MAP NO 16317 Status: Closed -Finaled Expiration Date: 02/05/2024 Address: 2382 FARADAY AVE, # 140 IVR Number: 48020 CARLSBAD, CA 92008-7219 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 07/10/2023 07110/2023 BLDG-84 Rough 216690-2023 Passed Tim Kersch Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 0711212023 07112/2023 BLDG-16 Insulation 217114-2023 Passed Tim Kersch Complete Checklist Item COMMENTS Passed BLOG-Building Deficiency Yes BLDG-44 217113-2023 Passed Tim Kersch Complete Rough/Ducts/Dampers Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07/1312023 07113/2023 BLDG-11 217297-2023 Passed Tim Kersch Complete Foundation/Ftg/Piers (Rebar) Checklist Item COMMENTS Passed BLOG-Building Deficiency Yes 07114/2023 07114/2023 BLDG-34 Rough 217420-2023 Partial Pass Tim Kersch Reinspection Incomplete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07117/2023 07117/2023 BLDG~17 Interior 217535-2023 Passed Tim Kersch Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 08/08/2023 08/0812023 BLDG-85 T-Bar, Ceiling 219918-2023 Passed Tim Kersch Complete Grids, Overhead Wednesday, September 27, 2023 Page 1 of 2 STRUCTURAL CALCULATIONS A17HTK PROJECT: au l1 r z 2€:S z. r,A (l..A o,. 1 .A vE . 'i ~"~ MGc.,HL .5....cfPo'2-r STRUCTURAL ENGINEERS, l[P 14288 Dlnlllorl SIN • Sia. #200 • ~. CA 112084-8819 (858) ffl-811119 • WWW. HTI<SE.COM • Fax (858) 87IMl85V DESKIN ASSUMPTIONS: CONCRETE STRENGTH AT TWENTY EIGHT DAYS: ______ PSI ______ PSI MASONRY: GRADE "N· CONCRETE BLOCK F I M = MORTAR: TYPE S 1,800 PSI GROUT: 2000PSI REINFORCING STEEL: A-615 STRUCTURAL STEEL: A-38 LUMBER: DOUGLAS FIR-lARCH JOISTS BEAMS AND POSTS STUDS GRADE 40: GRADE 60: #2 #2 #4 AND LESS (U.O.N.) #16 AND LARGER STUD OR BETTER SEISMIC FORCE: '2 t G ~L.~)' REPORT BY: --=====---------- WIND FORCE: DESIGN LOADS: ROOF PEAD LOAD SLOPING ROOFING PLYWOOD JOISTS INSUL &CLG. MISC. TOTAL• ROOF LIVE LOAD SLOPING FLAT -REPORT NO.: ____ _ SOIL PRESSURE: A,OOR PEAD LOAD fil WALL PEAP LOAD ' I I FLOORING I ~ L-7 "-7. INTERIOR PL YWOOO 4->N e,... ., ~RIOR JOISTS ~ ~1)-1 'c, INSUL & CLG. I MISC. TOTAL= 10PSF 16PSF RECEIVED JUN 12 2023 CITY UF CARLSBAD FLOORLIVELQAP BUILDING DIVISION INTERIOR SP.,. PSF .,+ ~ r ,s. £ r,6-(L-r I -,-, a1,,..J BALCONY 60 PSF (U.O.N.) EXITWALKWAY 100 PSF These calculations are limited only to the Items Included herein, selected by the client and do not Imply approval of any other portion of the structure by this office. These calculatlons are not valid If altered in any way, or not accompanied by a wet stamp and signature of the Engineer of Record. Job No. Designed By Date ?3-ssi. H-~ S--3-Z.3 14288 Danielson Street • Suite 200 • Poway. CA 9208-4-8819 • (858) 879-8989 • Fax (858) 87~8959 ASCE. Address: 2382 Faraday Ave Carlsbad, Callfomia 92008 1.1!1) 'p{}~9 j~~ 'J, ... I ·---,~~ i ... ... ~· ~ --- h11P-1://a1ce 7hazan:llool.onllne/ .... ' a, ASCE 7 Hazards Report Standard: ASCE/SEI 7-16 Risk Category: 11 Soll Class: D -Default (aee Section 11.4.3) ,-~--· ~ 1 ---!" <' , . I , " 1. . Page 1 ot3 Latitude: 33.136616 Longitude: -1 17.274875 Elevation: 321 .19764519958414 ft (NAVD88) Wed May 03 2023 i ASCE. Seismic Site Soll Cina: D -Default (see Section 11.4.3) Results: Sa : 0.963 So, NIA S1 : 0.352 TL : 8 Fa : 1.2 PGA : 0.42 Fv : NIA PGAw : 0.504 SMI 1.155 FPOA 1.2 Sw1 : NIA I, : 1 Soe : o.n Cv : 1.281 Ground motion hazard analyals may be required. See ASCE/SEI 7-16 Section 11.4.8. Data AccMHd: Wed May 03 2023 Date Source: usGs se1arolc Design Maps Jmpa://aace7haZardtool onJlne/ Page2 of3 Wed May 03 2023 L~TE<lA'--5T!if;I~, rr : r-f ~ t>,4 ~ ~~ ( I -t '2 ~ ) V\..lf ~r .St>~ = o.17 °'-f :t I~ o ~ ~ .2•~ Fr ~ ti, +-C 1 ... ) ("•7 7) ( ~) wP ➔ 1. +- ~ .. s F-r ""''". -= ~ ~ ~"J. tr w\ ➔ '.-+ =-"· ,~ wp '5~\~. ~I.) o ~ 4>--z, lbs. (1. u~ ~ 1 ~ t'-.. d, T, r1. -:.. I~ L ri,) ~ Z4-,::, .{'_ \t, ~~. f"Y1 """", -.. 4-:sl' ( Q.1 'i) ~ ,z_) -:::. ,1 I I {) -I t • ~. 4 -( 2. ~ ~0 + I. t-;) :. No llfl.1 Fl ? L-1 Di~~ f=o (U..(:-: ~ u, I'- ~ c....10\~ FolL'--e fu,2.. (;rot: = 1 ~ -= ~t:) L.,,,-,e, PEil. ~-... ~ ~ ~() It.. u~ 2. -/2''¢ ,~ $Cf2.r:,v Pen-71!7~ M t.-J , cs , '-'/ :;._ '' r-i, ~. Pe-..J , 1 N"lb r (lJ..~ (Y\~,-=-ll.l b4£ -?'.. /c.. '-- v .:>I lo,.., .,__ I / 7 0 11.r. f I -=-1{ ho )C to0 t'~ 'l. -l~ Page 18of64 Report No. NER-11,j;/ MICRO.=LAM~ LVL BEARING DETAILS l!AJIINO AT l!XT!AtOR WALL Strap per code if IDp plate II not continuous DY&r header. "" '11mmerl. SN~ 2I Top mount SN"MICRO-I.AM9LVL FrwnlngConnec10r1• on page 14. (ij) ::;,~ (@hanger l_2 ■!ARNO FOR DOOR l3 HAIi TO HAM OIi W1ND0W Hl!AD&II CONNICTION Fpmount hqer NOTE: IIEARINO LINOTH 18 EXTREMELY CAl11CAL AND MUST Bl!~ FOR l!ACH APPUCATION. Protect wood In dll'lld contact with concnta. IUAINCI AT CONCMT'IWALL Wood post SINI peat with mumn cap wllh column cap NOff: Yartfy colulm capelty and bNrtng 1eng1,.a..pagi21&mlnknum bNttngllnglh. ■~ATWOOD OR ITHL POIT TJr JOIST DESIGN PROPERTIES 1414· Wlclh ,._ • Minimum of 2 rowt Uld ndl O 12· o.c. • Mlnmum of 3 rowe of 18d nalll O 12• o.c. 1or 14•, 11•, and 1a• beM,e. 1-111• W1clh ...._ • Minimum of 2 rowa 112• boltl O 24• o.o. ltaggefed. NC>ff: For aide lolded mulllpla member beame, adclllolial nallng orboltlng ~ may be requlrad. SN page 28. ~ CONNECTION OF IIUL11Pll PEca OF TOP L0ADID 8EAMI IIIIX. l!nd llmdnun --A11clfon ..... Int. o:t:1 Wt. Ex10' -lL.ba.) flelctton ...... (PLF) (ln'U..) 10CMti·· 10CMII No. W.I. w.a. T.11"/H 9,. 1.9 170 eoe eoe 1733 2210 111• 2.0 285 990 m 1733 2210 14 2.2 424 1180 1000 1733 2210 18 2.4 578 1315 1000 1733 2210 T.ll"IH 1PAI 2.8 374 990 990 2415 2915 14 2.8 560 1180 1100 2415 211115 18 3.0 746 1315 1100 2415 2915 T.ne/51 I! 111• 3.7 583 1580 1200 3000 3000 14 I 3.9 866 1770 1200 3000 3000 ..... u, 4.1 I llOU ' rt970J 1200 3000 3000 --•wt,en the veneer layup pattern reeulta ,n flange thlckneleal other 1han 11k lnchee nomlnal, the ~Ullment of l8dlon proper1iee for moment r8liltal ice and El la pet mil!lld. • •Shea, valuel taken from NER-200. *The following formula approximate8 the uniform load deflection of 4 (inches) llofmnt (Ft.-U..) 10CM 2940 3836 '4820 5881) 52155 &460 7570 8080 9906 I 116'5 I 1 4 • 22.Sw/4 + 4.44w/2 ForT.11"111 El d x 10' and T.ll"/85 4 22..Sw/ 4 3.33w/2 • El + d x ,C)I For T .r,aa I! w • uniform load in pounds per lineal foot t • clear span in feet d • out to out depth of the joist El • value from table NOTE: The end reaction values above are baled on an a.au~ minim, wn hAArlnn i•nntk nt 1 si.• r ,w ' ' 7 ..J .l 1W ,,,.,. , .... ,.. .,_,.. __ _ 1 r1,_... ,,,... t T 11--7 .! ... ,,.., ,,,,.. ~__J w., .. ..__J -.-t 1W' ~ 111111j 14," Of 11· T .I 'Ill jclllla 1\lr" 11flll,' , .... , •• .. , ... ,....., .... OFFICE USE ONLY SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE RECORD ID# ___ ~~------------- PLAN CHECK #7'1-fGE..-i.'0+-------------1 Business Contact Dane Fetherling , 'J Y BP DATE Project Address (include suite) 2382 Faraday Avenue, Suite 140 City Carlsbad APN# 212-062-18-00 Mailing Address (include suite) 2382 Faraday Avenue, Suite 140 Project Contact Kristie M. Berrill City Carlsbad Applicant E-mail kris@maggettielam.com Telephone# 619-624-0521 Plan File# The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: fnot required for projects within the City of San Diego): Indicate by circling the item. whether your business will us_e, process, or store any of the following hazardous materials. If any of the items are circled. applicant must contact.gie Fire Protection Agency with junsd1ction pnor to plan submittal Occupancy Rating: Facility's Square Footage (including proposed project): 3,44o 1. Explosive or Blasting Agents 5. Organic Peroxides 9 Water Reactives 2 Compressed Gases 6 Oxidizers 1 O Cryogenics 3 Flammable/Combustible Liquids 7. Pyrophorics 11 Highly Toxic or Toxic Materials 4. Flammable Solids 8. Unstable Reactives 12 Radioact1ves 13. Corrosives ~?ther Health H.azards ~one of These PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH -HAZARDOUS MATERIALS DIVISION (HMD): If the answer to any of the questions is yes. applicant must contact the County of San Diego Hazardous Materials Division. 5500 Overland Avenue, Suite 170, San Diego, CA 92123 Call (858) 505-6700 prior to the issuance of a building permit FEES ARE REQUIRED Project Completion Date Expected Date of Occupancy· 0 CalARP Exempt I 1 2 3 4. 5. 6 7. 8. YES NO □ GJ □ GJ □ GJ □ □ □ □ □ (for new construction or remodeling projects) Is your business listed on the reverse side of this form? (check all that apply). Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? Will your business store or handle carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22. Article 1 0)? Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). Date ~Is D ca;,,AfS Requ;red Dale tJ-, Oca~mplete I Date C.1nrtjs / PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): The following questions are intended to identify the majonty of a,r pollution issues at the planning stage Your proiect may require additional measures not identified by these questions. Residences are typically exempt, except-single building with more than four dwelling units and those with more than one detached residential buildings on the property-e.g. granny flats [+Excludes garages & small outbuildings not used as dwelling units]. If yes Is answered for the questions below please see link for further instructions: here or for more comprehensive requirements. please contact apcdcomp@sdapcd.org or call (858) 586-2650. YES NO □ 0 2. □ IZ] 30 •□ □ IZ] Will the project disturb 100 square feet or more of existing building materials? If yes, submit an asbestos survey to apcdcomp@sdapcd.org Will any load supporting structural members be removed? If yes submit an asbestos survey and demoht1on notification to apcdcomp@sdapcd.org at least 10 working days prior to starting the demolition of a load bearing structure. A notrficatmn Is required even if no asbestos is present In the structure (ANSWER ONLY IF QUESTION 1 IS YES) Will 100 square feet or more of friab!e asbestos matenal be disturbed? If yes, submit a not1ficatIon of asbestos removal to apcdcomp@sdapcd.org at least 10 working days prior to starting asbestos removal. Will any equipment or operations be installed that may require an APCD Permit to Operate? Please see the reverse srde of this form for typical equipment requiring an APCD permit If yes, contact APCD prior to the issuance of a building permit Briefly describe business activities: Briefly describe proposed project HQ building and R&D area for Orthopedic Medical Devise Co. machine shop and break/work room I declare under penalty of perjury that to the best of my knowledge and beli d correct 2211(.,;cri Name of Owner or thorized A e Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION------------------------------------ BY DATE· I I EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO' APCD COUNTY-HMO APCD COUNTY-HMO APCD -A stamp 1n this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may sttll apply HM-9171 (01/22) County of San Diego -DEH -Hazardous Materials Division □ □ □ □ □ □ □ □ □ □ □ ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY Date: 2/8/2023 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com c€\\l€-D . ?-. € , 1st1.1 Business Name: Breg Tl Suite 140 ~'\l. \\ S'or,..O Street Address: 2382 Faraday Avenue, Suite 140 Carlsbad, CA 92008 c: cf>..t<-\-\S\01'1 --------------:,,'<f-'{ o, 01\J Email Address: kris@maggettielam.com C~11_01\'IG PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT (ON REVERSE SIDE CHECK TYPE OF BUSINESS) I ✓/ Check all below that are present at your facility: Acid Cleaning 0 Food Processing D Metal Powders Forming Assembly D Glass Manufacturing 0 Nutritional Supplement/Vitamin Automotive Repair D Industrial Laundry 0 Manufacturing Battery Manufacturing D Ink Manufacturing O Painting/Finishing Biofuel Manufacturing O Laboratory D Paint Manufacturing Blotech Laboratory D Machining/Milling 0 Personal Care Products Bulk Chemical Storage D Membrane manufacturing D Manufacturing Car Wash D (i.e waterfilter membranes) D Pesticide Manufacturing/ Packaging Chemical Manufacturing D Metal Casting/Forming 0 Pharmaceutical Manufacturing Chemical Purification D Metal Fabrication D (including precursors) >- Dental Offices D Metal Finishing D Porcelain Enamelrng D Dental Schools D Electroplating 0 Power Generation ...... D Dental Clinics 0 Electroless Plating D Dry Cleaning 0 Anodizing □ Print Shop --D Research and Development) □ Electrical Component D Coating (i.e. phosphating) D Rubber Manufacturing □ Manufacturing 0 Chemical Etching/Milling D Semiconductor Manufacturing □ Fertilizer Manufacturing D Printed Circuit Board 0 Soap/Detergent Manufacturing □ Film/ X~ ray Processing 0 Manufacturing D Waste Treatment/Storage New Business? YesONol=J SIC Code(s) if known: Date operation began/will begin: ______ _ Tenant Improvement? Yes E]NoO If yes, briefly describe improvement Tl to include new laboratory with (4) new !ab areas, conference room, machine shop and break/work room Description of operations generating wastewater (discharged to sewer, hauled or evaporated): __________ _ Estimated volume of industrial wastewater to be discharged (gal/ day) List hazardous wastes generated (type/volume) _____________________________ _ Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? YesODate: _____ No□ Page 1 of 2 .. Development Services Building Division { City of Carlsbad CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 C £. \ \J ~\)araday Avenue BE. 442-339-2719 11,.?\l. I.) 6 '2.\l'Qww.carlsbadca.gov 0 PURPOSE This checklist is intended to help building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their project. This completed checklist (B-50) and summary (B-55) must be included with the building permit application. The Carlsbad Municipal Code (CMG) can be referenced during completion of this document. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool The B-50 checklist was originally developed several years ago to support implementation of the CAP. Recent updates to the California Building Standards Code have imposed newer performance standards on building permit applications. Therefore. the applicant is advised to review all applicable code sections and apply the maximum performance standard. which may exceed the CAP consistency checklist requirements Consultation with a certified Energy Consultant is encouraged to assist in filling out this document. Appropriate certification includes, but is not limited to: Licensed, practicing Architect, Engineer, or Contractor familiar with Energy compliance, IECC/HERS Compliance Specialist, ICC GB Energy Code Specialist, RESNET HERS rater certified, certified ICC Residential Energy Inspector/Plans Examiner, ICC Commercial Energy Inspector and/or Plans Examiner, ICC CALgreen Inspector/Plans Examiner, or Green Building Residential Plan Examiner. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, check N/A and provide an explanation or code section describing the exception. )-- The project plans must show all details as stated in the applicable Carlsbad Municipal Code (CMG) and/or Energ\ :;'de and Green Code sections. . Breg Tl Machine Shop/Lab BP No.: Date 2/14/20i PropertyAddress/APN 2382 Faraday Avenue, Suite 140 Carlsbad, CA 92008 Applicant Name/Co. Kristie M. Berrill Maggetti Elam Associates, Inc. Applicant Address: 3160 Camino Del Rio South, Ste. 207 San Diego, CA 92108 Contact Phone: 619-624-0521 Contact Email: kris@maggettielam.com Contact information of person completing this checklist (if different than above): Name: Company name/address: 8-50 Contact Phone: Contact Email: Page 1 of 7 Revised 12/22 Use the table below to determine which sections of the Ordinance checklist are applicable to your project. For alterations and additions to existing buildings, attach a Permit Valuation breakdown on a separate sheet. For purposes of determining valuation. the amount should be upon either the actual contract price for the work to be permitted or shall be determined with the use of the current "ICC Building Valuation Data" as published by the International Code Council, whichever is higher (refer to Section 18.04.035 of the CMG). Building Permit Valuation (BPV) $ breakdown ___________ _ D Residential □ New construction '2A', 3A', 4A' 'Includes detached, newly constructed ADU □ Additions and alterations: □ BPV < $60,000 NIA All residential additions and alterations □ BPV d60,000 1A,4A 1-2 family dwellings and townhouses with attached garages □ Electrical service panel upgrade only only. 'Multi-family dwellings only where interior finishes are □ BPV;,, $200,000 1A, 4A' removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are orooosed 28' 'Multi-family dwellings only where ;,,$1,000,000 BPV AND BPV ~ $1,000,000 affecting ;>,75% existing floor area ~ Nonresidential and hotels/motels □ New construction 1 B, 28, 38, 48 and 5 I!! Alterations: I!! BPV;,, $200,000 or additions;,, 18,5 1,000 square feet □ BPV;,, $1,000,000 1 B, 28, 5 Building alterations of;,, 75% existing gross floor area ;,, 2,000 sq. ft. new roof addition 28, 5 1 B also applies if BPV ~ $200,000 Instructions: 1. Choose first between residential or non-residential based on the type of project being submitted. 2. Next chose between new construction or addition/alteration for residential or non-residential. 3. The columns to the right of your selection will determine which sections of the CAP program are applicable to your project. 4. Appropriate details must be included on the plans for selections made. EXAMPLE Scope of work includes a new, 2 story, single family residential structure. The selections would be: Residential and New construction in the table above. For a 2-story structure, CAP sections 2A, 3A and 4A would be applicable. (Solar PV, water heating, EV charging) The• indicates that new detached ADU's are included. EXAMPLE: Scope of work includes a tenant improvement (1.e., alterations) valued at over one million dollars. The selections would be: Non-residential and Alteration BPV" $1,000,000 CAP sections 18, 28 and 5 would be applicable to this project. (Energy efficiency, Solar PV and Transportation Demand Management (TOM)') It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a pertormance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. 3 1. Energy Efficiency Please refer to Section 18.30.060 of the Carlsbad Municipal Code (CMC) and Section 150.2 of the CEC for more information. Appropriate details and notes must be placed on the plans according to selections chosen in the design. A. 0 Residential addition or alteration ;;, $60,000 building permit valuation. Details of selection chosen below must be placed on the plans referencing CMC 18.30.060. D N/A ________ _ Year Built Single-family Requirements □ Before 1978 Select one option: D Duct seal in a D Attic insulation D Cool roof □ 1978 and later Select one option: □ Liqhtina packaqe D Water heatinq oackaqe □ 8etween1978 -1991 □ 1992 and later □ Exception: Home energy score ;;,7 (attach certification) Multi-family Requirements □ Attic insulation Select one option: D Duct sealina D Attic insulation □ Cool roof Select one option: D Liahtina packaae D Water-heating package B. 0 New Nonresidential construction (including additions over 1,000sl), new hoteUmotel construction AND alterations;;, $200,000 building permit valuation. See Section 18.21.050 of the CMC and CALGreen Appendix AS. At least one measure from each applicable building component required. □ NIA 490,999.51 AS.203.1.1 Choose one: □ Outdoor lighting □ Restaurant service water heating (Section 140.5 of the CEC) □ Warehouse dock seal doors □ Daylight design PAFs □ Exhaust air heat recovery AS.203.1.2.1 Choose one: D .95 Energy budget (Projects with indoor lighting OR mechanical) D .90 Energy budget (Pro1ects with indoor lighting AND mechanical) AS.211.1" D On-site renewable energy: A5.211.3" □ Green power: (If offered by local utility provider. 50% minimum renewable sources) A5.212.1 □ Elevators and escalators:(Project with more than one elevator or two escalators) AS.213.1 □ Steel framing: (Provide details on plans for options 1-4 chosen) * High-rise residential buildings are 4 or more stories. □ NIA ---------- □ NIA _______ _ □ NIA 0 NIA □ NIA □ NIA ** For alterations~ $1,000,000BPV and affecting> 75%existing gross floor area, OR alterations that add 2,000 square feet of new roof addition: comply with Section 18.030.040 of the CMC (section 2B below) instead. 4 2. Photovoltaic Systems A. □ Residential new construction. Refer to Section 150.1(c)14 of the CEC for single-family requirements and Section 170.2(d) of the CEC for multi-family requirements. If project includes installation of an electric heat pump water heater pursuant to CAP section 3 below (residential water heating), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA or SARA #d.u. Calculated kWdc' Exception sheets if necessary) □ D □ □ Total System Size· kWdc kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.) "Formula calculation where CFA = conditional floor area, #du= number of dwellings per plan type If proposed system size is less than calculated size, please explain B. 0 Nonresidential, hotel/motel and multifamily additions, alterations and repairs of these projects 2:$1,000,000 BPV AND affecting 2:75% existing floor area, OR addition that increases roof area by 2:2,000 square feet. Please refer to Section 18.30.040 and 18.30.070 of the CMC when completing this section. Choose one of the following methods: (Gross floor area or Time-Dependent Valuation method) D Gross Floor Area (GFA)Method GFA Min.System Size: kWd □ If< 10,000s.f. Enter:5 kWdc D If~ 10,000s.f. calculate 15 kWdcx (GFN10,000) .. .. Round building size factor to nearest tenth, and round system size to nearest whole number. D Time-Dependent Valuation Method C. 0 Annual TDV Energy use:•••------~x .80= Min. system size: ______ kWdc ... Attach calculation documentation using modeling software approved by the California Energy Commission. • All newly constructed non residential, hotel/motel and highrise mult~amily buildings that are required by CEC section 140.1 0(a) to have a PV system shall also have a battery storage system meeting CEC section 140.10(b). Non residential, hotel/motel and multifamily additions, alterations or repairs that trigger solar due to the Carlsbad Climate Action Plan will NOT require battery storage. Battery storage is required when triggered by CEC section 140.1 0(a) and/or 170.2(g). 5 3. Water Heating A. Residential. Refer to Section 18.30.050 of the CMC and Sections 150.1(d) or 170.2(d) of the CEC when completing this section. Provide complete details on the plans. Residential new construction and alterations: □ Required: 60% of energy needed for service water healing from on-site solar or recovered energy. For systems serving individual units, choose one system: □ Single 240-volt heat pump water heater AND compact hot water distribution AND Drain water heat recovery (low-rise residential only) □ Single 240-volt heat pump water heater AND PV system .3 kWdc larger than required. □ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher. □ Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors □ Gas or propane system 11<th a solar water hearing system and recirculation system. For systems serving multiple units, choose one system: □ Pump water hearing system with recirculation loop tank with electric backup and recirculation system. □ Solar water heating system that is either: □ .20 solar savings fraction □ .15 solar savings fraction. plus drain water heat recover OR: □ System meets performance compliance requirements of section 150.1(d) or 170.2(d) and deriving at least 60% of energy from on-site solar or recovered energy. □ Exception: _____________________________________ _ B. Nonresidential and hotel/motel new construction. This section also applies to high-rise residential. Refer to Sections 18.030.020 and 18.040.030 of the CMC and Sections 140.5 and 170.2 of the CEC when completing this section. Provide complete details on the plans. 1. Non-residential: □ Required: Water heating system derives at least 40% of its energy from one of the following: □ Solar-thermal □ Photovoltaics □ Recovered energy □ Required: High-capacity service water heating system 2. Water heating system is (choose one): D Heat pump water heater O Electric resistance water heater(s) □ Solar water heating system with .40 solar savings fraction 3. Hotel/motel: □ Required: High-capacity service water heating system (meeting Section 170.2(d) of the CEC) □ Required: Localed in garage or conditioned space Exception: 6 4. Electric Vehicle Charging A. 0 Residential• New construction and major alterations.' This section also applies to hoteUmotel projects. Refer to Section 18.21.030 of the CMC and Section 4.106.4 of the GBSC when completing this section. Choose one: □ One and two-family residential dwelling alterations with no electrical panel upgrade (No EV space required) □ ADU (no EV space required when no additional parking facilities are added) □ One and two-fami~ residential dwellings with attached garage and electrical panel upgrade □ One EV Ready parking space required □ Exception: __________ _ □Newand major atterations to multi-family and hotel/motel projects: □ Exception: _________________ _ Total Parking Spaces Proposed EVSE Spaces EV Capable (10% of total) I EV Re adv (25% of Total) I EV charaers (5% of Total) I I 'Major alterations are: (1) for one and two-family dwellings and for town houses with an attached garage, alterations have a buildrng permit valuation~$60,000 or include an electrical service panel upgrade. (2) for multifamily dwellings (three units or more without attached garages). alterations have a building permit valuation~ $200,000, interiorfinishesare removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B. D Non-Residential -New construction □ Exception: _____________ _ Please refer to Section 18.21.040 of the CMC when completing this section Total Parking Spaces Proposed EV Capable I EVCS (Installed '"'th EVSE) I EV Ready (optional) I EV Space (optional) I I I Calculation: Refer to the table below: Total Number of Parking Spaces provided Number of required EV Capable Spaces Number of required EVCS Installed with EVSE) □ 0-9 1 1 □ 10-25 4 1 □ 26-50 8 2 □ 51-75 13 3 □ 76-100 17 5 IJ 101-150 25 6 IJ 151-200 35 9 □ 201 and over 20 percent of total 25 percent of Required EV Spaces Calculations: Total EV Capable spaces= .20x Total parking spaces proposed (rounded upto nearest whole number) EVSE Installed= Total EVSE Spaces x .25 (rounded up to nearest whole number) EVSEothermaybe "EV Ready" or "EV Space" 7 5. Iii Transportation Demand Management (TOM): Nonresidential ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT City staff will use the table below based on your submitted plans to determine whether your permit requires a TOM plan. If TOM is applicable to your permit, staff will contact the applicantto develop a site-specific TOM plan based on the permit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses Office (all), 20 Restaurant 11 Retails 8 Industrial 4 Manufacturing 4 Warehousing 4 , Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10thEdition 13 11 4.5 3.5 3 1 , For all office uses, use SAN DAG rate of 20 ADTl1,000 sf to calculate employee AOT , Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Samole calm1la1ions· Office: 20,450 sf 1. 20,450 sf 11000 x 20 = 409 Employee AOT Retail: 9,334 sf 1. First 1,000 sf= 8 AOT 2. 9,334 sf -1,000 sf= 8,334 sf 3. (8,334 sf I 1,000 x 4.5) + 8 = 46 Employee ADT I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my pe;rt require a TOM plan and understand that an approved TOM plan is a condition of permit issuance. Applicant Signature: ~ ~ ~ Name Kristie M.Berrill V Date 2/14/2023 Phone No. 619-624-0521 8 Building Permit Finaled Revision Permit Print Date: 09/27/2023 Job Address: 2382 FARADAY AVE, # 140, CARLSBAD, CA 92008-7219 Permit No: Status: (city of Carlsbad PREV2023-0178 Closed -Finaled Permit Type: BLDG-Permit Revision Work Class: Commercial Permit Revision Parcel#: 2120621800 Valuation: $0.00 Occupancy Group: B #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: 40 Code Edition: 2022 Sprinkled: Yes Project Title: Track#: Lot#: Project#: Plan#: Construction Type:VA Orig. Plan Check#: CBC2023-0087 Plan Check#: Applied: 08/23/2023 Issued: 09/14/2023 Finaled Close Out: 09/27/2023 Final Inspection: INSPECTOR: Description: BREG: REVISION TO CHANGE 1ST FOR COMMON AREA RESTROOMS FOR ADA COMPLIANCE Applicant: MAGGETTI ELAM ASSOCIATES INC KRISTIE BERRILL 3160 CAMINO DEL RIOS, # 207 SAN DIEGO, CA 92108-3834 (619) 624-0521 FEE BUILDING PLAN CHECK FEE (manual) BUILDING PLAN CHECK REVISION ADMIN FEE Property Owner: CEI OFFICE FUND 8 LLC 16870 W BERNARDO DR, # 360 SAN DIEGO, CA 92127 (714) 990-2100 Total Fees: $275.00 Total Payments To Date: $275.00 Building Division Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $240.00 $35.00 $0.00 Page 1 of 1 APPLICATION MISSING FOR THIS PROJECT 1