HomeMy WebLinkAboutCT 04-14A; TRAILS END; ADDENDUM TO THE GEOTECHNICAL REVIEW OF MECHANICALLY STABILIZED EATHR (MSE) WALLS; 2017-11-08RE061V17Ei3 _o.i
NOV2OZOl7I -
LAND DEVELOPMEN5ith
ENGINEERING
Date
Geotechnical e Geologic a Coastal o Environmental
5741 Palmer Way a Carlsbad, California 92010 • (760) 438-3155 • FAX (760) 931-0915 • www.geosoilsinc.com
TECHNICALMEMO RAN DUM
DATE: November 8, 2017 W.O. 6635-F-SC
TO: Donna Drive, LLC
5505 Canca De Golf
t4
Rancho Santa Fe, California 92091
.'
Attention: Mr. Brian Dorman VY No. 19' c..' Li fl ( No. RCE 477
" rflQfflg / *Exp. IL
Geologist From: Robert G. Crisman, CEG 1934 or C David W. Skelly, RCE 47857
SUBJECT: Addendum to the Geotechnical Review of Mechanically Stabilized Earth
(MSE) Walls, Trails End Development, CT 04-14, Carlsbad, California
References: 1. "Geotechnical Review of Mechanically Stabilized Earth (MSE) Walls, Trails End
Development, CT 04-14, Carlsbad, California," W.O. 6635-F-SC, Dated November 2, 2017,
by GeoSoils, Inc.
"Keystone Retaining Walt Plans for: Trails End Development, CT 04-14," Sheet KW1, Job
No. 17201 dated September 25, 2017, by ABl Engineering Consultants, Inc.
'Precise Grading Plans For: Trails End Development, CT 04-14," 5 Sheets, DWG No. 481 ZE -
1A, Job No. 13136, dated June 28, 2017 (City Approval date), by Masson &Associates, Inc.
"Geotechnical Update and Plan Review, Trails End Development, Carlsbad, California,"
W.O. 6635-Al-SC, dated June 6, 2016, by GeoSoils, Inc.
"Geotechnical Update Evaluation, Proposed Trails End Development, Northwest Corner
of the Donna Drive and Carlsbad Village Drive Intersection, Carlsbad, San Diego County,
California," W.C. 6635-A-SC, dated November 27, 2013, by GeoSoils, Inc.
In accordance with your requestand authorization, GeoSoils, Inc. (GSl) has reviewed the
referenced wall plan with respect to site soil conditions and the geotechnical reports.
Based on our review, this addendum to the geotechnical review, dated November 2, 2017
(see Reference No. 1) was prepared.
The MSE wall (per Reference No. 2) does not appear to have reinforcing grid in it.
The design guidelines prepared by Keystone Retaining Wall Company (available
online) appear to indicate that gravity walls are only allowed up to 4.67 feet for a 2:1
sloping surcharge and a select backfill type (i.e., siltysand, phi = 30, c= 50, unit
weight = 120 pcf).
There is currently no testing of onsite soil to support the 30 degree phi angle used
in the design. An evaluation of shear strength for soils within the foundation zone
for the wall indicated a phi angle of 20 degrees, a cohesion of 317 psf, and a density
of 130 pcf. Recommend that the wall engineer revise design to account for actual
foundation zone conditions.
Soil to be used for wall backfill, i.e., retained zone and/or reinforced zone soils are
not currently present onsite. As such, GSI will need to obtain soil sample of
potential backfill and evaluate shear strength prior to use. Our experience suggests
that a select soil with a phi angle of 30 degrees, and a cohesion of 50 psf (i.e. silty
sand) will exhibit as-built densities on the order of 130 pcf, not the 120 pcf used. in
design. As such, GSI recommends a unit weight of 130 pcf be used in design with
respect to the reinforced and retained zones.
An evaluation of global stability (static and seismic) was performed for the current
plan slope configuration and MSE wall (per Reference No. 3), using known
parameters for foundation zone soils, as well as anticipated parameters for
reinforced and retained zone soils, our evaluation indicated a factor of safety (FOS)
of at least 1.5 (static), however, the FOS for the seismic, analysis was less than the
minimum criteria of FOS 2~ 1.15. Additional analysis, including the use of geotextile
grid behind the MSE wall was performed, based on our analysis, an adequate factor
of safety for both static and seismic conditions is achieved when a minimum two (2)
layers of Miragrid 5XT (or equivalent), with a minimum length of 18 feet, are used
within the walls "reinforced" zone. Printouts of the stability analysis for the
reinforced wall conditions are attached.
The conclusions and recommendations presented in the referenced reports remain
pertinent and applicable and should be appropriately implemented during project
planning, design, and construction. The conclusions and recommendations presented
herein are professional opinions. These opinions have been derived in accordance with
current standards of practice, and no warranty, either express or implied, is given.
Standards of practice are subject to change with time. GSI assumes no responsibility or
liability for work or testing performed by others, or their inaction; or work performed when
GSI is not requested to be onsite, to evaluate if our recommendations have been properly
implemented. Use of this report constitutes an agreement and consent by the user to all
the limitations outlined above, notwithstanding any other agreements that may be in place.
In addition, this report may be subject to review by the controlling authorities.
Attachments: Stability Analysis for Reinforced MSE Wall Conditions
Donna Drive, LLC W.O. 6635-B-SC
Trails End, CT 04-14, Carlsbad November 8, 2017
File* e:\wpl2\6600\6635fatt.memo GeoSoils, h. Page 2
230
210
190
0
6635-F-SC Trails End - Static, Mirafi 5XT @ 18'
rf,'I df d,,nn 'I'i".I'.&,,ro thflihA1i ..7.17'-f-r. m wII - thIir - ytnrir - 1R n12 Run By: GeoSoits. Inc. 11/8/2017 01:31 PM
# FS Soil Soil Total Saturated Cohesion Friction Pore Ptez. Load Value Intl Points: 36. to 36.2
a 1.586 Desc. Type Unit WI. Unit WI. Intercept Angle Pressure Surface LI 2000 Term Limits: 78. to IOU.
b 1.587 No. (pci) (pci) (psi) (dog) Param. No. L2 500 psf
c 1.588 cot 1 120.0 125.0 317.0 20.0 0.03 0
d 1.589 all 2 130.0 135.0 50.0 30.0 0.01 0
o 1.591 a12 3 130.0 135.0 317.0 20.0 0.01 0
I 1.591 Tsa 4 120.0 125.0 500.0 30.0 0.00 0
gl.592 a
h 1.593
i 1.594
r—
Wt IL
j 1.594 I
-- - ..... ... ............. .///f.. ...... -3.i
2
7
2
-
.22_T0T__,_ : L.._
. Lb/f, :
._.
2
13
3 3 : 3
H
20 40 60 80 100 120
GSTABL7 v.2 FSmin=1 .586
Safety Factors Are Calculated By The Modified Bishop Method
6635-F-SC Trails End - Seismic, Mirafi 5XT @ 18'
x:\shared\word perfect data\carlsbad\6600\6635 donna drive, llc\slope stability\11-7-17\6635-f-se mse wall -seismic - 5xtgrid - 2.p12 Run By: GeoSoils, Inc. 11/8/2017 01 :3OPM I_:....f.
# FS Soil Soil Total Saturated Cohesion Friction Pore Piez. Load Value nit Points: 36. to 36.2
a 1.158 Desc. Type UnitWt. UnitWt. Intercept Angle Pressure Surface LI 2000psf Term Limits: 78. to 100.
b 1.159 No. (pcI) (pcI) (psf) (deg) Param. No. L2 500psf
C 1.159 col 1 120,0 125.0 317.0 20.0 0.03 0 Peak (A) 0,460(g)
d 1.159 all 2 130.0 135.0 50.0 30.0 0.01 khCoef. 0.15Og<
e 1.160 a12 3 130.0 135.0 317.0 20.0 0.01 0 V oe. 0.10 g
1 1.160 Isa 4 120.0 125.0 500.0 30.0 0.00 0
gl.160 a
h 1.161 —h
i 1.161 LIIe'cP
1 .161
.................................................... ,.._... _3J..
7/
'I
. --------- _.. ..
1N
2 3"2
3,3 3 3 I 1
Ia 3 1 1 I
4 . i6
H
I Ii
20 40 60 80 100 120
GSTABL7 v.2 FSmin=1.158
Safety Factors Are Calculated By The Modified Bishop Method
230
210
190 L
0