HomeMy WebLinkAboutCT 05-10; POINSETTIA PROPERTY; SECOND SUPPLEMENTAL GEOTECHNICAL RETAINING WALL DESIGN RECOMMENDATIONS; 2011-02-15Earth Strata,
Geotechnical, Environmental and Materials Testing Consultants
I BETTER PEOPLE • BETTER SERVICE • BETTER RESULTS
February 15, 2011 Project No. 10707-1C
Mr. Walter Miller
K. HOVNANIAN HOMES
1500 South Haven Avenue, Suite 100
Ontario, CA 91761
Subject: Second Supplemental Geotechnical Retaining Wall Design Recommendations, The
Tides Development, Located on the Southwest Corner of Poinsettia Lane and Lowder
Lane, City of Carlsbad, San Diego County, California
Pursuant to your request, Earth-Strata has provided supplemental retaining wall design
recommendations for the retaining walls utilizing the regional standards. The following
recommendations may be utilized for the proposed C-i, C-4, and C-6 retaining walls planned at the
subject property, as indicated on the grading plan Sheet Nos. 4, 5, and 10.
RETAINING WALLS
Active Earth Pressures
Foundations may be designed in accordance with the recommendations provided above and within the
referenced report. The following table provides the minimum recommended equivalent fluid pressure
for design of retaining walls a maximum of 6.5 feet high, per the enclosed calculation sheet. The active
earth pressure should be used for design of unrestrained retaining walls, which are free to tilt slightly. &
MINIMUM STATIC EQUIVALENT FLUID PRESSURES (pcI)
PRESSURE TYPE BACKSLOPE CONDITION
2:1 (h:v) BACKSLOPE
Active Earth Pressure I 36
The retaining wall parameters provided do not account for hydrostatic pressure behind the retaining
walls. Therefore, the subdrain system is a very important part of the design. All retaining walls should be
designed to resist surcharge loads imposed by other nearby walls, structures, or vehicles should be added
to the above earth pressures, if the additional loads are being applied within a 1:1 plane projected up
from the heel of the retaining wall footing. As a way of minimizing surcharge loads and the settlement
potential of nearby buildings, the footings for the building can be deepened below the 1:1 plane projected
up from the heel of the retaining wall footing.
EARTH- STRATA, INC. 26047 JEFFERSON AVENUE, SUITE C, MURRIETA,CA 92562 OFFICE (951) 461-4028 • FAX (951) 461-4058 - WWW.EART STRATA.COM
BE-i 1 ER PEC)PL I- - BEl....I ER SERVICE - BE ii ER RESULIS
I I
The opportunity to be of service is appreciated. Should you have any questions or require further
clarification, please notify our office at your earliest convenience.
Respectfully submitted,
lEA RT1HL=STRATA\, ]INC.
Chad E. Welke, PG, CEG, PE
Principal Geologist/Engineer
CW/am
QC' " `
NO. C63712
* EXP. 0-30- I ( 1*
OF
Attachments: Retaining Wall Calculation Sheet No.4 (Rear of Text)
APPENDIX A References
Distribution: (1) Addressee
(4) Craig Kahlen, Rick Engineering
Project No. 10707-10C 2 February 15, 2011
RETAINING WALL
JN: 10707-IA CONSULT: &
I PEOPLE.
PROJECT: Khov/Carlsbad
CALCULATION SHEET# 4
CALCULATE THE DESIGN MINIMUM EQUIVALENT FLUID PRESSURE (EFP) FOR PROPOSED RETAINING
WALLS. THE WALL HEIGHT AND BACKSLOPE AND SURCHARGE CONDITIONS ARE LISTED BELOW.
ASSUME THE BACKFILL IS SATURATED WITH NO EXCESS HYDROSTATIC PRESSURE. USE THE
MONONOBE-OKABE METHOD FOR SEISMIC FORCES.
CALCULATION PARAMETERS
EARTH MATERIAL: Compacted Fill - Silty Sand WALL HEIGHT 6.5 feet
SHEAR DIAGRAM: I BACKSLOPE ANGLE: 27 degrees
COHESION: 331 psf SURCHARGE: 0 pounds
PHI ANGLE: 28 degrees SURCHARGE TYPE: U Uniform
DENSITY 130 pcf INITIAL FAILURE ANGLE: 35 degrees
SAFETY FACTOR: 1.5 FINAL FAILURE ANGLE: 70 degrees
WALL FRICTION 0 degrees INITIAL TENSION CRACK: 5 feet
CD (C/FS): 220.7 psf FINAL TENSION CRACK: 100 feet
PHID = ATAN(TAN(PHI)/FS) = 19.5 degrees
HORIZONTAL PSEUDO STATIC SEISMIC COEFFICIENT (kh) 0 %g
VERTICAL PSEUDO STATIC SEISMIC COEFFICIENT (ku) 0 %g
CALCULATED RESULTS
CRITICAL FAILURE ANGLE 46 degrees
AREA OF TRIAL FAILURE WEDGE 25.9 square feet
TOTAL EXTERNAL SURCHARGE 0.0 pounds
WEIGHT OF TRIAL FAILURE WEDGE 3370.2 pounds
NUMBER OF TRIAL WEDGES ANALYZED 3456 trials
LENGTH OF FAILURE PLANE 7.2 feet
DEPTH OF TENSION CRACK 3.9 feet
HORIZONTAL DISTANCE TO UPSLOPE TENSION CRACK 5.0 feet
CALCULATED HORIZONTAL THRUST ON WALL 6.5 pounds
CALCULATED EQUIVALENT FLUID PRESSURE 0.3 pcf
DESIGN EQUIVALENT FLUID PRESSURE 36.0 pcf
THE CALCULATION INDICATES THAT THE PROPOSED RETAINING
WALLS MAY BE DESIGNED FOR AN EQUIVALENT FLUID PRESSURE
OF 36 POUNDS PER CUBIC FOOT.
APPENDIX A
REFERENCES
APPENDIX A
References
Earth-Strata, Inc., 2010, Interpretive Report for Infiltration System, Proposed 29-Lot Residential
Development, Located on the Southwest Corner of Poinsettia Lane and Lowder Lane City of
Carlsbad, San Diego County, California, dated May 6.
________• 2010a, Preliminary Geotechnical Interpretive Report, Proposed 29-Lot Residential Development,
Located on the Southwest Corner of Poinsettia Lane and Lowder Lane City of Carlsbad, San
Diego County, California, dated May 11.
________• 2010b, Geotechnical Review of Draft Retaining Wall Alternative Analysis Report, Proposed 29-Lot
Residential Development, Located on the Southwest Corner of Poinsettia Lane and Lowder
Lane City of Carlsbad, San Diego County, California, dated May 25.
2010, Preliminary Turf Block Recommendation Letter, Proposed Residential Development,
Located on the Southwest Corner of Poinsettia Lane and Lowder Lane, City of Carlsbad, San
Diego County, California, dated September 14.
2010, Geotechnical Review of Foundation Plans for the Proposed 25-Lot Residential Development,
Located on the Southwest Corner of Poinsettia Lane and Pasceo Del Norte, City of Carlsbad,
San Diego County, California, dated October 20.
________• 2010, Supplemental Geotechnical Retaining Wall Design Recommendations, Proposed Poinsettia
Residential Development, Located on the Southwest Corner of Poinsettia Lane and Lowder
Lane City of Carlsbad, San Diego County, California, dated October 20.
'2010, Update Geotechnical Retaining Wall Design Recommendations, Proposed La Marea
Residential Development, Located on the Southwest Corner of Poinsettia Lane and Lowder
Lane City of Carlsbad, San Diego County, California, dated November 11.
________• 2010, Geotechnical Evaluation of Storm Water Management for the Proposed 25-Lot Residential
Development, Located on the Southwest Corner of Poinsettia Lane and Pasceo Del Norte, City
of Carlsbad, San Diego County, California, dated November 11.
_______• 2011, Revised Geotechnical Evaluation of Storm Water Management and Recommendations for
Side Yard Drainage for the Proposed 31-Lot Residential Development, Located on the
Southwest Corner of Poinsettia Lane and Pasceo Del Norte, City of Carlsbad, San Diego
County, California, January 25.
Lawson and Associates, Inc., 2005, Preliminary Geotechnical Investigation Report, Proposed 29-Lot Residential
Development, Southwest Corner of Poinsettia Lane and Paseo Del Norte, City of Carlsbad, California, dated February
24.