HomeMy WebLinkAboutCT 2017-0005; 800 GRAND AVENUE; WATER SIZING CALCULATIONS; 2018-12-17Water Sizing Calculations
Village Walk Townhomes
341 - 347 Oak Avenue
Carlsbad, California
CT 2018-0005
ROW 2018-0573
DWG NO. 513-7
Prepared For:
TMS Oak Investments 8, LLC
29250 Paseo Sedano
San Juan Capistrano, CA 92675
951.801.0888
Prepared By:
Surender Dewan, P.E.
DMS Consultants, Inc.
12371 Lewis Street, Suite 203
Garden Grove, California 92840
714.740.8840
December 17, 2018
----- '-1 'I'\ T
FEB 2 52019
LAJ DE\1LOPMENT
¶rcDr
L4 ,\Lr.i '
DMS
CONSULTANTS, INC.
CIVIL ENGINEERS
VILLAGE WALK
CARLSBAD
WATER FLOW GENERATION
(Ref. City of Carlsbad, Engineering Standard, Volume 2, Chapter 3)
Average daily flow for multi family dwelling unit = 250 gpd
Peaking factor = 2.90
Peak demand = 725 gpd
Peak demand for 8 units = 725 x 8 = 5800 gpd = 4 gpm
WATER SUPPLY FRICTION LOSS CALCULATION
rsey'44etbrs %. "~__ @
HORIZON
Em i es Z
Features
APPLICATIONS: For use in the measurement of potable water for
applications where flow is consistently moderate to high. Designed
for applications where accuracy is an essential part of maintaining
revenue. The Horizon horizontal turbine meter is built to maintain
accuracy over extended periods of use.
CONFORMANCE TO STANDARDS: Horizon turbine meters have
some of the widest flow ranges of any turbine meters on the
market. All Horizon series turbine meters meet or exceed the latest
performance and accuracy standards of AWWA C701. Maximum
continuous flow rates may be exceeded by as much as 25% for
intermittent periods.
CONSTRUCTION: The Horizon consists of three basic parts:
maincase; measuring insert: and register. Maincases are made of
bronze. Measuring elements are thermoplastic with unique inlet
and outlet straightening vanes.
To simplify maintenance, the Horizon is designed to allow quick,
easy, in-line exchange of the measuring element without remov-
ing the maincase from the installation. Interchangeability of many
parts within various sizes minimizes spare parts inventory and the
Horizon comes standard with built-in strainer.
REGISTER: Permanently sealed register has a unique seal and
heat-treated glass to eliminate dirt, moisture infiltration and lens
fogging. An integral tamper-proof locking feature is provided to
prevent tampering of the register and calibration vane. The total-
izing register has a straight-reading odometer type display: 3600
test circle with center sweep hand and a low flow (leak) detector.
Standard gearing is used, making registers interchangeable by
size.
All Hersey Meter models have electronic meter reading systems
available for increased reading efficiency (see Meter Reading
Systems.)
OPERATION: Water flows straight through the measuring element
where it turns a rotor at a rate in direct proportion to the quantity
of water flowing through the meter. The straight-through design
allows high volumes to flow with a minimum of head loss. Retro
ThrustO design extends the life of the meter by dividing wear
between two points: during low flowthe tungsten carbide bearing
in the rotor floats against a stainless steel shaft; during high flow
a second tungsten carbide bearing gently moves back against
another stainless steel shaft. During medium flow, the rotorfloats
between both tungsten carbide bearings with sapphire bushings
providing radial support for the rotor.
STRAINER & TEST PORT: Standard Built-in Strainer. Test port is
optional with spool piece.
CONNECTIONS: ANSI Class 150 Flanges. 1 -1/2' NPT pipe threads
on optional test outlet.
Materials and Specifications
D MODEL DESIGNATION .................................................HORIZON
11 SIZES ......................................... .. ......................................... 1-1/2,2"
D STANDARDS .............Manufactured and tested to meet or exceed all
applicable parts of ANSI/AWWA C701 class II Standard.
fl SERVICE .....................................................Cold water measurement.
D NORMAL OPERATING FLOW RANGE .... See Chart on page 3.2.
D ACCURACY .....................................................See Chart on page 3.2.
1 PRESSURE LOSS ...........................................See Chart on page 3.2.
D MAXIMUM WORKING PRESSURE ................................. 175 PSI
D TEMPERATURE RANGE .................F to I OU°F water temperature
0 MEASURING ELEMENT ............Stainless Steel and Thermoplastic
0 REGISTER TYPE ...................Straight reading, permanently sealed,
magnetic drive with low flow indicator. Remote Readings units optional.
D MATERIALS .....................................Maincase - bronze UNS 84400;
Casing bolts - Stainless steel ANSI B 18; Rotor - Thermoplastic; Rotor
radial bearing - Sapphire: Rotor thrust bearings - tungsten carbide: Rotor
bearing pivots - Stainless steel ANSI B 18; Magnet - rare earth/ceramic;
Register box and lid - Thermoplastic or optional bronze:
Standard strainer - Stainless steel: Spool piece with test outlet - bronze.
0 INSTALLATION ..............................................Horizontal or Vertical
0 METER CONNECTIONS ..................... 1-1/2' —2" ANSI Class 150
0 OPTIONS .......................................................AMR Reading Systems
3,1
Rev. 04-06
1.
309
C.)
C.) C.)
—
rseyoAete.
-fl ,r•__- orizontal TUrbinMtW'
Meter iRegistrati on
Meter Size Initial Dial* Capacity Initial Dial* Capacity
1-1/2 100 Gallons 100 Million 10 Cubic Feet 10 Million
2" 100 Gallons 100 Million 10 Cubic Feet 10 Million
*Registration equal to one full revolution of the sweep hand.
Flow Characteristics
Meter
Size
Typical Low Flow
(95% Minimum)
Typical Operating Range
(100%:t 1.5%)
Maximum Continuous
Operation
Maximum Intermittent
Flow
1-1/2 2 GPM 4 to 120 GPM 120 GPM 160 GPM
2" 2-1/2 GPM 4 to 160 GPM 160 GPM 200 GPM
Performance* Dimensions & Weights
1-1/2" HORIZON
RATE OF FLOW - U.S. GPM
'Performance curves are typical only and not a guarantee of performance
ummmmmmammmmmmmmm -
immmmmmmmmmmmmmmmmm ....••..a••••l• : isommmmmmmmmmmmmmwm.-
immmmmmmmmmmwmmmmmm _ _•a•..._.......MMM -
2" HORIZON
MESEEMEMENEEMEN ••uuuu••uuuuauuaa
llm•UMUUUU••UUU•l• IIUUUUUUU•*•UU•U$UUNU•U IIUUSUUN•U••UUU•••U•U
Nu•SRu•••Uu••ll
mom
3.2
Rev. 04-06
Meter Size 1-1/2" 2"
A Compact Length 9 10
AA Standard Length 13 17
B Height 7-3/4 7-3/4
C Centerline 1-3/4 2-1/8
D Holes 3/4 3/4
EWidth 6-1/8 6-1/8
F Flange 3/8 3/8
-
Net Weight Compact -LBS 22 23
Net Weight Standard - LBS 26.5 32
- Certification \
)
Meters ccmolv with NSF/ANSIGI N5PANS1372. and conl'omis with lead content rsuirontanls fx iead-lretfptumbinq as defined by the U.S. Sale DlinklngWaler Act effective Jan 1. 2014
Temperature 105' F (40' C) max
Pressure 150 psi operating max
Materials 8ody/cplgs EcoBrass'
Internals
Magnet
Engineered thermoplastic
Alnico
Accuracy +1-1.50/6 of reading within Qt-Qmex
Sensor Reed switch
Maximum Current 20 mA
Maximum Voltage 24 Vdc or Vac
Cable Length 12 (4m) std (2000 max run)
.5
0
U .2
.5
0mm Or On Omnx
Flow (gpm)
e000rssS 0(CflZ8 muioy-Ieno DOmpOSuan IS IC55 rrien U. I15 ey welgru
Size
062 = 5/8"xl/2"
075 = 518"x314"
100 = 3/4"xl"
100F = 1"
150 = 1 1/2"
200 = 2"
www.flows.com IJUL
Model Codes - How to Order
GLF -075-R/IOF'
Examples: GLF-075-RIIOG is a 3/4w
meter with a pulse output (reed switch)
sensor with a pulse rate of 10 gallons/pulse
GLF-200 is a 2 meter with totalizer only
Pulse Rate fif applicable)
RJ20P = 20 pulse/gal only in 5/8"&3/4'
RI10P = 10 pulse/gal only in 519&3/4
RI4P = 4 pulse/gal
RJ2P = 2 pulse/gal
R/I P = 1 pulse/gal
R/5G = 5 gal/pulse
R/10G = 10 gal/pulse
R/50G = 50 gal/pulse
R/IOOG= 100 gal/pulse
Totalizer only meter would have nothing after the size designation
855-871-6091
I . S
GLF Series
NSF61!ANS372 Certified I1 çr Lead-FreeMulti-Jet Water Meters .
GLF Series water meters use the widely accepted multi-jet
principle, as a gear train drives the register totalizer dials.
For pulse output meters, a reed switch sensor is attached to \ ''
the outside of the lens and detects a magnet arm that has N. c•
replaced one of the dial pointers. The reed switch output is /
a dry contact closure and does not require power. \
Main Technical Data
—Nomi—nal dlame ON 062- 518"x112" 075-518"x314" 100- 314"xl" IOOF. 1" 150-1 112' 200- 2"
Maximumulowrale US gpm Omax 20 20. 30 50 100 160
Nominal flow rale US gpm On
Transition flow rate US gpm 01
10 10 15 - 25 50 80
1 1 2 - 3 5 8
Minimum flow late US gpm Omin 0.25 0.25 0.5 1 0.75 1.5 1 2
Minimum reading US gallon 0.005 0.005 0.05 0.05 0.05 0.05
Accuracy Curve Specifications