Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
895 TAMARACK AVE; ; FPC2017-0110; Permit
1iTl F1E1I1I Caty Of ClIm Print Date: 08/16/2022 Job Address: 895 TAMARACK AVE, CARLSBAD, CA 92008-4109 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2060402900 Track #: Valuation: $167,883.68 Lot t: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check #: Permit No: FPC2017-0110 Status: Closed - Finaled Applied: 05/04/2017 Issued: 06/21/2017 Finaled Close Out: 04/13/2021 Final Inspection: INSPECTOR: Stowe, Daniel Wong, Cindy Project Title: Description: TAMARACK SHELL - SPRINKLER MONITORING (NEW SYSTEM) CoApplicant: FIRE WIRE SYSTEMS INC-INACTIVE 34593 AGONIS WAY WINCHESTER, CA 92596-8791 (619) 254-1302 FEE AMOUNT FIRE Sprinkler Monitoring $371.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7165-0559:0144 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECUR11Y1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models *lFP..50 and *5700 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: IFP-50, 5700 Control Units 7628 EOL Resistor 5860/5860R/RA-1000 Annunciator 5897 Power Supply 5496 *Notification Power Expander 5824 Serial/Parallel Interface 5865-3/5965-4 LED Annunciator 5880 LED 10 Module 5883 Relay Interface Board SD500-LIM Line Isolation Module SD505-61 B Isolation Base RA-100 Remote Annunciator 3158 Reverse Polarity Module 5220 Direct Connect Module RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control units for use in high-rise structures when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Also suitable for non-high rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. Rev 10-3-08MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the tern listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0144 Page 2 of 2 NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev 10-3-08MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, 5K -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, lDP-Monitor, IDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, IDP-Control, IDP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor rnodules,and *IDPREYMON2 *SKREYMON2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to, listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and lDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7150-0559:0161 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models SK-PULL-SA and SK-PULL-DA single/dual action fire alarm pull boxes. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, .and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-0028:0199 04-16-09 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL F FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0149 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models lDP-PHOTO, lDPPHOTOR*, IDP-PHOTO-T, IDP-ACCLIMATE, SK-PHOTO, SKPHOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models IDP-PHOTO and IDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-bUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 *Rev. 02-01-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP,3225 Cumberland Blvd, Suite 300, Atlanta; GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7G0004, TG7GFS04, and TG7GA004 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7G0004 and TG7GA004 are household application and Mode TG7GFS04 is for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. Corrected 10-09-13 jp This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV,G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SK-Minimon Specifications Compatibility D SILENT KNIGHT by Honeywell SK-Minimon Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the lntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description r - The SK-Minimon is an addressable monitor modules for use with the lntelliKnight fire alarm control panels (FACPs). The SK-Minimon acts as an interface to contact devices, such as waterfiow switches and pull stations. The SK-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. Features Single contact monitor SK-Minimon support for Class B (Style B) contact monitor wiring Small and lightweight size allows for flexible mounting options Rotary address switches for fast installation UL listed Electrical Standby Current: 400 uA max 24 VDC with comm. Voltage Range: 15 - 32 VDC End of Line Resistance: 47 k Ohms Physical Dimensions: 2.75" W x 1.3" H x 0.5" D Weight: 1.2 oz (37 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing The SK-Minimon is compatible with the following lntelliKnight Systems: 5820XL 5820XL-EVS 5808 5700 5600 (Rev 2.0 or higher) SK-FFT Listings UL CSFM FM IN S OUT Compati SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shalt furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. Other Devices Wiring the SK-Minimon D SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are FORM# 350133 Rev E subject to change without notice. For more information, contact Silent © 2013 Honeywell International Inc by Honeywell Knight 12 Clintonville Road, Northford, ci 06472-1610 Phone: (800) 328-0103, Fax:(203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com D SILENT KNIGHT by Honeywell SK-Pull-SA and SK-Pull-DA Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's lntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the lntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight lntelliknight series fire alarm control panels (FACPs). Features Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) Meets ADA requirement for 5 lbs maximum pull force to active Shell, door, and handle molded from durable LEXAN® Reliable analog communications for trouble-free operation Braille text on station handle Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled Rotary address switches for fast installation UL Listed, including UL 38, Standard of Manually Actuated Signaling System SK-Pull-SA SK-Pull-DA Compatibility The SK-Pull-SA and SK-Pull-DA are compatible with the following InteIliKnight FACP's: 5600 5700 5808 5820XL 5820XL-EVS Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. I .............................................................................. OUT Class B Compatible FACP ClassAWIring: Cla$s B Wring: Wiring SK-Pull-SA & SK-Pull-DA Pull Stations Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5" (14 cm) Average Operating Current (LED flashing): 300 pA Width: 4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 321 - 120°F (0°C - 49°C) Si-Colored LED: Humidity: 10% - 93% non-condensing Blinking Green: Normal Steady Red: Alarm Accessories Switch: Single pole, single throw (SPST) normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA to keep our product information up-to-date and accurate. We cannot cover KNIGHIT D all specific applications or anticipate all requirements. All specifications are FORM# 350135 Rev C subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 © 2013 Honeywell International Inc. Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Model 5700 Improvements in SKSS deliver five times faster upload/downloads Built-in RS-232 interface for programming via PC Built-in Form C trouble relay rated at 2.5A at 27.4 VDC Programmable date setting for Daylight Saving Time Installation The 5700 is a surface mount FACP Compatibility The 5700 signal line circuit (SLC) supports multiple device types of the same protocol: D SILENT KNIGHT 0 by Honeywell lntelliKnight® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control panel solution. lntelliKnight Model 5700 is a class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The basic lntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 supports SD or SK devices. 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Built-in support for up to 50 SK detectors and 50 SK modules creating a total point capacity of 100 points Built in support for up to 50 SD devices Up to 125 zones and 125 output groups Uses standard wire—no shielded or twisted pair required Built-in digital communicator Central station reporting by point or by zone Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC Drift compensation 13 pre-programmed output cadences (including ANSI- 3.41) and 4 programmable outputs Notification circuits configurable as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power Built-in synchronization for AMSECO, Gentex®, Faraday, System Sensor® and Wheelock® appliances Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system • SK accessories Upload or download programming, event history, or • SD detector status onsite or from a remote location using You cannot mix SD and SK SLC devices on a FACP. a PC and 5660 Silent Knight Software Suite (SKSS) Two built-in Form C programmable relays rated at 2.5A at27.4VDC ' r r LI I 6XMTW,O, Mft EKPh~ Ln* W'tU% sMd4t&4 SE.PftO.t Z'... ft O4(4ftt ,4* A$tt4b fts5t Mc,ká 4ns,ath ',$,t:S St*3U M1S$ Mtt€&M4, M&t. ' ,-n, tft Mn Z7 - M flt,n,M4 M724M0 I BMMMM taMp MV48} LX MMCCL) aaLXe4,Qn ?ftgñ*, Cnn) ) 'Las Las X.a.a -. rr— Lt8gL),, SX.lMa, ML? LX n" 5700 ri Uad 'L LOX :ij1 == 5496 Model 5700 Fire Alarm Control Panel Specifications Electrical Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC Notification Power: 2.5A @ 27.4 VDC, power-limited Standby Current: 200 mA Alarm Current: 365 mA Notification/Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power-limited Battery Charging Capacity: 7.0-35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet. Physical Dimensions: 12.75W x 15.2" H x 3.4" 0 (32.39 W x 38.42 H x 8.57 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Listings NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 144; MEA429-92-E Vol. XVI; OSHPD (CA) OSP-0065-10 S-BUS Accessories 5860/11 Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power-limited notification appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite User-friendly Windows software for remote programming of 5700s using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End-user facility management software allows viewing of detector status and event history via modem or direct connection, RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D SK-SCK Seismic Compliance Kit) S0505-DTS-K Remote test switch that provides remote key operated test function and annunciation of detector alarm with 50505-DUCTR. SD and SK Devices See the data sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices data sheet 53623 5K Devices data sheet D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject P/N 350392 Rev L to change without notice. For more information, contact Silent Knight 12 © 2013 Honeywell International Inc. by Honeywell Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com ATA TELGUARD I%LT TG=7FS CELLULAR ALARM COMMUNICATOR 6 COMMERCIAL FIRE PRODUCT FEATURES Meets UL 864 requirements for sole, primary or backup path communications. Supports virtually all alarm formats for universal panel compa tibility. Connects to your central station's PSTN or IP receivers. Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS is-t he ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2010 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system, replacing all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within five minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS because of the new five minute supervision mode. The TG-7FS can also be installed as a backup path, and upgraded to sole path at a later date. (t))) --N P,.eI TG-7S 7, .7 Telguard technology allows full data reporting for unlimited point- to-pdint signal details.nd maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. UL Listings Commercial Fire 864 Control units & accessories for fire alarm systems Commercial Burglary 365 Police Station connected burglar alarm units and systems 1610 Central station burglar alarm units Residential 985 Household fire warning Systems 1023• Household burglar alarm systems (U LWJ ELECIRONIC icrcn NFPA LISTED U INTERNATIONAL Telguard, a Division of Telular Corporation 2727 Paces Ferry Road SE Suite 1-800 Atlanta, GA 30339 USA 800-229-2326, Option www.lelguard.com Copyright '2011 Telular Corporation All Rights Reserved 0 TELG UARD TG=7FS CELLULAR ALARM COMMUNICATOR I = D SILENT KNIGHT by Honeywell SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that-surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACP5). For more information about the lntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description Optional remote LED annunciator (System Sensor® PN RA100Z) SK-Photo and SK-Photo-T are plug-in Plug-in mounting provides ease of type smoke sensors that combine a installation photoelectric sensing chamber with Tamper-proof feature available on addressable analog communications. Point ID mounting bases capability allows each detector's address to be set with rotary Listed for use in duct applications address switches, providing exact Rotary address switches for fast detector locations for selective installation maintenance when chamber UL Listed contamination reaches unacceptable FM Approved S levels. 5K-Photo and SK-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the SK-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The SK-PhotoR is a remote test capable detector for use with the DNR/DNRW duct smoke detector. (not included) Features Sleek, low-profile design Base included Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the SK-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3600 visibility Detector transmits signal to indicate maintenance is required %,C1 Vila Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) installed in B501 base Electrical Operating Voltage: 15-32 VDC Standby Current: 300 pA @ 24 VDC Maximum Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature SK-Photo: 320 - 120°F (0°C - 49°C) SK-Photo-T: 321 - 100°F (0°C - 38°C) Humidity: 10% - 93% non-condensing Other Ratings SK-Photo-T Thermal: Fixed temperature set point 135°F (57°C) Velocity: 0 - 4000 fpm (0 - 20 m/sec) SK-Photo (Base included) Installation The SK-Photo and SK-Photo-T plug into a compatible lntelliKnight-series detector base. The SK-PhotoR is a remote test capable detector head included within the DNR (W) duct smoke detector. Compatibility SK-Photo, and SK-Photo-T are compatible with the following detector bases: B21OLP 6" base (included) B501 2 wire base B224RB Relay base B224B1 Isolator base B200SR Sounder base The SK-Photo, SK-Photo-T, and 5K- PhotoR are compatible with the following lntelliKnight FACPs: 5820XL 5820XL-EVS 5808 5700 5600 (Rev 2.0 or higher) Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's InteIliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B21OLP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Wiring SK-Series Detector Mounting Bases D SILENT This document is not intended to be used for installation purposes. We t)( to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350118 Rev E subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Outdoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrA lertV Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, IP56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from —40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings SIGNALIN FM MEA 7300-1653 187 (o.td.., strobes) () LISTED 7t25-653 188 (horr strobes, S4051 (ch,rnes, horn utr000s, nOrrrs) APPI1OVED approved chore strobes) S3593 ioutdoos arid alert strobes) 3023572 M7A452 55-E 7135-653 189 (horn S, Cs ores) SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40°F to 151°F Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase ajplication flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlerl Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorling spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side fanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 34-inch top and bottom conduit entries and 34-inch knock-outs at te back. A screw-in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185, Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature —40°F to 151°F (-40°C to 66°C) Strobe Rash Rate i flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 - Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6'L x 4.7"W x 2.5'D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.61 x 4.7W x 1.3D (142 mm Lx 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-W88) 5.7l x 5.1 'W x 2.0"D (145 mm L x 130 mm W x 51 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSO12D1 UL Current Draw Data ._•j 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures listed candela ratings must be reduced in accordance with this table. --------.-.------.------ Horn Tones and Sound Output Data 8-1Z516-33 Switch Sound Volts Volts - ,..... - _..... .an n,%ennnr% rIAIfl 1 24-Volt Nominal Reverberant Anechoic nfl rta,n nfl flAffl Listed Candela Candela rating at —40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 Wall-Mount Horn Strobes erproof Back Box SpectrAlert Advance Diagrams Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information IL Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High Cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) F4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Walt Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add "-F" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate. WTP and WTPW "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 1S%"S7iEib? 3825 Ohio Avenue • St. Charles, IL 60174 Product speciticatoos subj @20 2 System Sensor, ect ochagecetboutewce, Visit systemuensor.coe _:_$ Phone: 800-SENSOR2 • Fax: 630-377-6495 to, current product torroasonincluding the latest version oI this data sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA\f.BCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh rs This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires i June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I