HomeMy WebLinkAbout2685 STATE ST; ; FA150077; Permit8/15/22, 5:13 PM FA150077 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FAI 50077 Job Address: 2685 STATE ST Status: ISSUED Permit Type: FALARM Applied 12/7/2015 Parcel No: 2030540700 Approved: 12/7/2015 Lot #: 0 Reference No.: Issued: 12/7/2015 PC #: Inspector: Project Title: RAILYARD LOFTS NEW FIRE ALARM SYSTEM Applicant: FIRE WATCH 437 EL CAJON BL EL CAJON, CA 619-2993473 Owner: BENJAMIN MARK P0 BOX 7050 RCHO SANTA FE CA Fees ($) Add'l Fees ($) Total ($) Balance ($) [. 212 F a 212 0 1/1 FILE COPY, DF-5241 8:E1 • Al -20 C!) MS-9050UD(E) Fire Alarm Control Panel with DACT = by Honeywell -.-.-.--..-------------- General . -. The Fire.Lite MS-9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules. With an exten- sive list of powerful features, the MS-9050UD programs just like Fire-Lite's larger products, yet fits into applications previously served only by conventional panels. The MS-9050UD's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the pub- lic switched telephone network. It also allows remote and local programming of the control panel using the PK-CD Upload! Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with WindowsTh 95 or greater, and compatible modem with a speed of 14.4 kbps or faster and Fire-Lite Upload/Download software kit PK-CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walk-test data, current status and system voltages. The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polarity/city box transmitter. (4XTMF) New options include a UL listed printer, PRN-6F and the new IPDACT Internet Monitoring module.The FireWatch Series inte- net monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two telephone lines. Although not required, the second- ary telephone line may be retained providing backup communi- cation over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9050UD is used in this data sheet to refer to both the MS-9050UD and the MS- 905OUDE FACPs. For MS-905OUDG, refer to DF-60445. Features Listed to UL Standard 864, 9th edition. Auto-program (learn mode) reduces installation time. Reports two devices set to the same address. On-board DACT. Two independently programmable Style Z (Class A) or Style V (Class B) NAC circuits. Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. Two programmable relays and one fixed trouble relay. Built-in Programmer. Telephone Line Active LEDs. EIA-232 PC interface. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. History file with 500 event capacity. Automatic detector sensitivity testing (NFPA 72 compliant). Automatic device type-code verification. Point troubpe identification. Waterfiow selection per module point. Alarm verification selection per detect-or point. Maintenance alert warns when smoke detector dust accumu- lation is excessive. One-person audible or silent walk test with walk-test log and printout. System alErm verification selection par detector point. PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant). Up to eigh- ANN-BUS annunciators Remote Acknowledge, Alarm Silen:e, Reset and Drill via addressabe modules or remote annunciator. Upload/Download (local or remote) of program and data via integral DACT. SLC COMMUNICATION LOOP Single adcressable SLC loop which meets NFPA Style 4, 6 and 7 requirements. 50 addressable device capacity (ary combination of address- able detectors and modules). Compatible with Fire'Lite's addressaaIe devices (refer to SLC Wiring Manual). NOTIFICATION APPLIANCE CIRCUITS (NACS) Two independently programmable output circuits. Circuits can be configured for the following outputs: - Style Y (Class B) - Style Z Class A) - Door Holder Service (cannot be LSE d for notification appliances) - Aux Power Source (cannot be usEd for notification appliances) Silence Inhibit and Autosilence timer options. Continuous, March Time, Tempo-a or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization er NAC. 2.5 A total power for NACs. NOTE: Maximum or total 24VDC system power shared between all NAG circu,ts and the ANN-BUS is 2.7 A. FA150077 DF-5241 3:E1 • 1/27/12 - Page 1 of 4 MS-9050U0 I Fire Alarm LI 1'1 Control Panel B ANN-80 ri SD355 Printer Photo Detector Gateway ANN-S/PG AD355 Adapt Detector Graphic LED Module ANN-PG H LL.J H355/H355R/H355H1 Relay Module Heat Detector ANN-RLY P211 Strobe H Li Dual Monitor Module I P211 Strobe Power. Supply F [ PS FCPS 24FSB UJI 5D355T Photo/Thermal - - P211 I Strobe I Multi-Modules Monitor Module I • CRF-300-6 Six-Relay Control Module CMF-300-6 Six-Circuit Supervised Control Module MMF-302-6 Six-Zone Interlace Module [ • MMF-300-10 Ten-Input Monitor Module MMF-302 2-Wire Detector - Monitor Module U55L Beam Detector Duct Detector BEAM-335/(S) - ADDRESSABLE FIRE ALARM BG-12LXAooressable Manual Pull Station CONTROL PANEL PROGRAMMING AND SOFTWARE Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Two programmable Form-C relay outputs. 20 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package(order programming kit PK-CD, containing PS-Tools, separately). Upload/download system programming locally. User interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Trouble (yellow) Alarm Silenced signals (yellow) KEYPAD 16 key alpha-numeric pad Acknowledge/Step Alarm Silenced Drill (Manual Evacuate) Reset (lamp test) Product Line Information MS-9050UD(E): Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, chassis with transformer, backbox with door, plastic bag contain- ing screws, cables, key, etc., manual. (For MS-905OUDC, refer to DF-60445.) PK-CD: Contains PS-Tools programming software for Win- dows®-based PC computer (cable not included). DP-51050: Optional dress panel for the MS-9050UD. TR-CE: Optional trim ring for semi-flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB-55F for mounting. BAT Series: Batteries, see data sheet DF-52397. PRT/PK-CABLE: Cable printer/personal computer interface cable. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT, IPDACT-2/2UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- Page 2 of 4— DF-52418:E1 • 1/27/12 S net internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet df-52424 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in turn, mounts to the FACP chassis. Use AC-TRMBLK when wire nuts are not allowed for AC connections to the transformer. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a supervised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. ANN-SEC: Optional secondary ANN-BUS interface module. Note: Used only with firmware 3.0 or higher. COMPATIBLE ANNUNCIATORS ANN-80(-W): Remote LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclo- sure. (See DF-60241.) ANN-FILED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. SD355R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fast-response, low-profile heat detector that activates at 190°F/88°C. AD355: Low-profile, intelligent, "Adapt' multi-sensor detector (B350LP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detec'r with integral sen- sitivity test. D355PL: InnovairFIex low-flow non-relay duct-detector housing; includes SD355R. DNR: InnovairFlex low-flow r3n-relay duct-detector housing. (Order SD355R separately.) DNRW: InnovairFIex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order SD355R separately.) MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0(10.16cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302A: Similar to MMF-300A. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires reset- table 24 VDC power. Refer to the Device Compatibility Docu- ment for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0 (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power noti- fication appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0 (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. 1300: This module isolates the SLC loop from short circuit condi- tions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six-relay control module (Form-C relays). Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NOTE: For more information on Compatible Addressable Devices for use with the MS-9050U0, see the following data sheets (docu- ment numbers): AD355 (DF-52386), BG-12LX (DF-52013), CMF- 300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/CRF Series (DF- 52 130), CP355 (DF-52383), H355 Series (DF-52385), 1300 (DF- 52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300- 10 (DF-52347), MMF-302-6 (DF-52356), 50355/50355T (DF- 52384). ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): The 47k ohm assembly supervises the MMF-300, MDF-300, MMF- 301, and CMF-300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. DF-52418:E1 • 1/27/12 - Page 3 of 4 S SYSTEM SPECIFICATIONS - .... .- -.- S System Capacity Intelligent Signalling Line Circuits.........................................1 Addressable device capacity..............................................50 Programmable software zones...........................................20 Annunciators.........................................................................8 Electrical Specifications AC Power: MS-9050UD 120 VAC, 60 Hz, 3.0 A. MS-905OUDE: 240 VAC, 50 Hz, 1.5 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides con- nections for two NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 A. End-of-Line Resis- tor: 4.7k ohm, ½ watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A © 30 VAC (resistive). Form-C relays, nonpower-limited, nonsupervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.6'(57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 491C/32 - 120°F and at a relative humidity 93%:t 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. NFPA Standards The MS-9050UD(E) complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Net- work) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9050UD(E) control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:210 MEA: 442-06-E NOTE: See DF-60445 for ULC-listed model. FireLite® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. i . I I ENtINfERINC & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made inthe U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4of4—DF-52418:E1 • 1/27/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0210 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Model MS-9050UD addressable fire alarm control unit. Unit consists of one communication loop, two bell circuits, and three relay contact outputs for alarm, trouble and supervisory. Local, auxiliary, remote station, central station and proprietary (protected premise), automatic, manual, water flow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 3.0 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm . Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 07-07-2006 ø' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DF-52121:C • E-325 S MMF-300(A) Series, M DF-300(A) Addressable Monitor Modules Y ' " General Four different monitor modules are available for Fire•Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A)is a miniature monitor module a mere 1.3 (3.302 cm) H x 2.75 (6.985 cm) W x 0.5' (1.270 cm) D used to super- vise a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTM is a communication protocol developed by Fire'Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. designs. MMF.300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit MMF-300(A) (Type H) may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICA TIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DF-52121:C. 10/06/2010—Page 1 0f4 MMF-301 (A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems 1415 0 1 ADDRESS 11 4 LOOP 4 i0 5 TENS ONES oH Lu Q •o .jiI -J Lu I co Inj The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301 (A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3 (3.302 cm) high x 2.75' (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF.302(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF- 302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2 of 4— DF-52121 :C • 10/06/2010 MDF.300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM Approved S . CSFM: 7300-0075:0185 MEA:72-01-E Product Line Information NOTE: °A" suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51309. Architects/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF-52121:C • 10/06/2010 - Page 3 of 4 ISO 9001 MCINEERINC & MANUFACTURING QUHITY SYSTEMS Fire-Lite® and LiteSpeed® are registered trademarks and FireWatch is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. ______________ We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52121 :C • 10/06/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneyweIl.com DESIGN: Models MDF-300, MMF-301 MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DF-52384:C • E-160 C SD355(A) Series Addressable Photoelectric Smoke Detectors (a Flre.uTeeAtarms by Honeywell -- .. -- resi The SD355(A), SD355T(A), and S0355R(A) addressable, low- profile plug-in photoelectric detectors use a state-of-the-art pho- toelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire.Lite's Addressable Fire Alarm Control Panels (FACPs). The SD355T(A) adds thermal sensors that will alarm at a fixed tem- perature of 135°F (57°C). Since these detectors are address- able, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sen- sor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional acces- sory, PN RA100Z(A). The S0355R(A) is a remote test capable detector for use with D355PL(A) or DNR(A)/DNRW duct smoke detector housings. Features SLC loop Two-wire loop connection. Unit uses base for wiring. Addressing Addressable by device. Rotary, decimal addressing: 01 - 99 with MS-9200 series, and 01 - 159 with MS-9600 series. Architecture Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communicat- ing with the fire panel) and latches on in alarm. Mechanicals Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring - included). Other system features Fully coated circuit boards and superior RF/transient protec- tion. 94-VO plastic flammability rating. Low standby current. Options Remote LED output connection, PN RA100Z(A). / SD355(A) in B2IOLP(A) Base Applications Use photoelectric detectors in life-safety applications to provide a broad range of fire-sensing capability, especially where smol- dering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white fire resistant plas- tic. SD355(A) series plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation 5D355(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-/The resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class B) wiring. SD355R(A) mounts in a 0355PL(A) or DNR(A)/DNR W duct detector housing. Operation Each 5D355(A) series detector uses one of 99 possible addresses on the MS-9200 series and up to 318 (159 on each loop) on the MS-9600 series Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The addressable photoelectric sensor in the 5D355(A) series has a unique unipolar chamberthat responds quickly and uni- formly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.) without sending an alarm level signal. Because of its unipolar chamber, the SD355(A) series is approximately two times more respon- sive than most photoelectric sensors. This makes it a more sta- ble detector. DF-52384:C • 12/07/2011 - Page 1 of 2 S Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a MS-9200 series or MS-9600 series addressable fire alarm control panel. The results of the sensitiv- ity test can be printed off the MS-9200 series or MS-9600 series for record keeping. Specification Voltage range: 15 - 32 VDC (peak). Standby current: 300 pA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Size: 2.1(5.33 cm) high; base determines diameter. - B21OLP(A): 6.1" (15.5 cm) diameter. - B501(A): 4.1' (10.4 cm) diameter. - B200SR(A): 6.875(17.46cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. Weight: 3.6 oz. (102 g). Operating temperature range: for SD355(A): 0°C to 49°C (32°F to 120°F); for SD355T(A): 0°C to 38°C (32°F to 100°F). SD355R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Temperature: 0°C - 49°C (32°F - 120°F). Relative humidity: 10% - 93%, non-condensing. Listings Listings and approvals below apply to the SD355(A), 5D355T(A), and SD355RT(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or list- ing may be in process. Consult factory for latest listing status. UL Listed: S1 059. ULC Listed: S1059. CSFM: 7272-0075:0194. MEA: 243-02-E. FM approved. Product Line Information NOTE: "A" suffix indicates ULC Listed model. 5D355: Adressable photoelectric detector; B21OLP base included. SD355A: Sames as SD355 with ULC Listing; B21OLPA base included. SD355T: Same as 5D355 but with thermal element; B21OLP base included. SD355TA: Same as SD355T with ULC Listing; B21OLPA base included. SD355R: Remote test capable addressable photoelectric detec- tor for use with a D355PL(A) or DNRNDNRW duct detector housing; B21OLP base included. SD355RA: Same as SD355R with ULC Listing for use with a D355PLA or DNRA duct detector housing; B21OLPA base included. INTELLIGENT BASES NOTE: 'A" suffix indicates ULC Listed model. NOTE: The detector's plug-in base can be changed off for special applications. For details about intelligent bases and their mount- ing, see DF-60059. B21OLP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. 82005R(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A © 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B350LP(A) profile, or to convert older high-profile bases to low- profile. Fl 10BP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with SD355(A) only; box of 10. WCK-200B: White detector covers for use with SD355(A) only; box of 10. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. 02011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. - This document is not intended to be used for installation purposes. _______________ We try to keep our product information up-to-date and accurate. I SO 9001 We cannot cover all specific applications or anticipate all requirements. , MCIPARINI & MMIFACT1RINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52384:C • 12/07/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:0194 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Models SD350, SD350T, 5D355, 5D355R*, 5D355T and AD355 photoelectric type smoke detectors. Model SD350T and 5D355T has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. All units are suitable for open areas and inside duct installations with air velocities between 0-4,000 FPM. Models 5D355 and 5D355R* are also approved for . installations inside Fire-Lite Duct Housing D355PL (CSFM Listing No. 3242-0075:221) and System Sensor Duct Housing DNRW(CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-11-2010fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct . operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DF-52385:D • E-710 H355(A) Series IritIIirunt A,1drhI (2) RrellTeALarms Thermal Detectors by Honeywell General __-- I 0 The Fire-Lite Alarms H355(A) Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors provide open- area protection and are intended for use with Fire-Lite's addressable Fire Alarm Control Panels (FACPs). The H355(A) and H355R(A) sensors provide fixed tempera- ture alarm detection at 135°F (570C). The H355R(A) sensor also responds to rate-of-rise conditions of greater than 15°F (8.3°C) per minute, The H355HT(A) is a fixed high-tempera- ture detector that activates at 190°F (880C). These thermal detectors provide addressable property protection in a variety of applications. Two LEDs on each sensor light to provide a local, visible sen- sor indication. Remote LED annunciator capability is available using an optional accessory, the RA100Z. Features SLC loop: Two-wire SLC loop connection. Unit uses base for wiring. Addressing: Addressable by device. Rotary, decimal addressing: 01 - 159 with MS-9600 series, 01 - 99 with MS-9200 series. Architecture: Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device-type identifica- tion. Built-in tamper resistant feature. Built-in functional test switch activated by external magnet. Operation: Factory preset at 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate-of-rise triggers at 15°F (8.3°C) per minute for the H355R(A). 3601-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink red in Normal condition and turn on steady red in Alarm. Visible LEDs "blink" every time the unit is addressed. Mechanicals: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct-surface or electrical-box mounting. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelectric, ioniza- tion and thermal sensors. Other system features: Remote test feature from the panel. Walk test with address display. Low standby current. / .... H355(A) in B21OLP(A) Base 94-5V plastic flammability rating. Options: Remote LED output connection to optional RA100Z remote LED annunciator. Flanged surface mounting kit. Installation H355(A) Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class "B") wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of off-white fire-resistant plastic. The H355(A) Series plug-in intelligent thermal detec- tors are designed to commercial standards and offer an attrac- tive appearance. Operation Each H355(A) Series detector uses one of 159 (MS-9600 series) or 99 (MS-9200 series) possible addresses on a con- trol panel SLC loop. It responds to regular polls from the con- trol panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimu- lates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The H355(A) Series offers features and performance that represent the latest in thermal detector technology. DF-52385:D • 5/17/2013 - Page 1 of 2 Spefications Size: 2.1 (5.3 cm) high; base determines diameter. - B210LP(A): 6.1 (15.5 cm) diameter. - B501 (A): 4.1 (10.4 cm) diameter. - B200SR(A): 6.875 (17.46 cm) diameter. - B224RB(A): 6.2 (15.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Installation temperature: - H355(A), H355R(A): —4°F to 100°F (-20°C to 38°C). - H355HT(A): —4°F to 150°F (-20°C to 660C). Humidity range: 10% to 93% relative humidity (noncon- densing). Voltage range: 15 to 32 VDC peak. Standby current: 300 pA @ 24 VDC (one communication every five seconds with LED blink enabled). LED current: 6.5 mA @ 24 VDC. Mounting: B21OLP(A) flanged base, included. See "Product Line Information: Intelligent Bases" if using a different base. Fixed-temperature setpoint: 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. Product Line Information NOTE: "A" suffix indicates ULC Listed model. H355: Intelligent thermal sensor; 135° F (57° C); B21OLP base included. H355A: Same as H355 but with ULC Listing; B21OLPA base included. H355R: Same as H355 with rate-of-rise feature; B21OLP base included. H355RA: Same as H355R but with ULC Listing; B21OLPA base included. H355HT: Intelligent fixed high-temperature thermal detector; 190° F (88° C); B21OLP base included. H355HTA: Same as H355HT but with ULC Listing; B21OLPA base included. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: The detector's plug-in base can be changed off for special applications. For details about intelligent bases and their mount- ing, see DF-60059. B21OLP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B210LPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A © 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B350LP(A) profile, or to convert older high-profile bases to low-profile. Fl lOBP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21OLP(A) base. RAlOOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR213: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. Listings and Approvals Listings and approvals below apply to the H355(A) Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2517. ULC Listed (models H355A, H355RA, H355HTA). CSFM approved: 7270-0075:0195. FM approved. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. 02013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 - This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING &MANVEACI1JRING QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-523850 • 5/17/2013 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM AL • FIRE! LISTING SERVICE LISTING No. 7270-0075:0195 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Models H350, H355, and H355HT fixed temperature heat detectors. Models H350R and H355R rate-of-rise with fixed temperature heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: H350, H355, and H355HT 135 F fixed temperature H350R and H355R 15° F rate-of-rise H355HT 190° F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. NOTE: Rev. 05-06-05JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 0 df-50673:Rev • F-850 S 302 Series t.Antirintiin Ut fltrtnr 0 Fires tietarms by Honeywell General - The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detectors setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8 (10.48 cm). Base diameter: 2" (5.08 cm). Electrical Ratings 6-125VDC 5amps 6-25VDC lamp 125 VDC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50 x 50'(15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. I271phl.jpg Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-135/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-135/-194; 302-ET-135/-194; 302-135/-194) CSFM: 7270-0021:001 127 IdI1.I,f FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELL 0.040 ANODIZED ALUMINUM HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW DE CON HERMETIC SEAL Cut-Away View df-50673: Rev • 02/03/09— Page 1 of 2 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-135 135°F All-Weather Vertical Mounting Note 2 below 302-AW-194 194°F All-Weather Vertical Mounting 302-ET-135 135°F All-Weather Vertical Mounting Note 3 below 302-ET-194 194°F All-Weather Vertical Mounting 302-EPM-135 135°F Explosion Proof Mounting Note 4 below 302-EPM-194 1194°F Explosion Proof Mounting AP -P Decorative white plastic adaptor plate for mounting 302 and 302 AW to 4 outlet box NOTE 1: For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50' x 50' (15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properly spliced to 'THW" or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 112"(1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is Strictly prohibited. - This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. I SO 9001 _____________ We cannot cover all specific applications or anticipate all requirements. '1 UIf&EIlNC & MANIMCIIRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 - dt-50673:Rev • 02/03/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 1 LISTING SERVICE LISTING No. 7270-0021:0001 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Thermotech lnc.,2900 North 1000 West, Ogden, UT 84414 Contact: A. Mark Headley (801) 782-2233 Fax (801) 782-1746 Email: thermotechinc@hotmail.com DESIGN: Models 302, 302H, 302AW, 302E1 and 302EPM heat detectors. Units are open circuit, 1350 F, 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. Models 302-El or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC or VDC, 125 VDC 1350 F, 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302-ET and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal mount only. MARKING: Listee's name, model number, electrical and temperature rating and UL label. APPROVAL: . Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. *Rev. 05-01-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0. Date Issued: July 01, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing Expires June 30, 2016 df-60379:A1 • E-400 CRF-300(A) Relay Module (a FIreLuTeALarms by Honeywell The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTM is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFl). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 - 99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module arid a relay module. CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9A Resistive Non-Coded 125 VAC 0.9 A Inductive (UR5ms) Coded 30 VDC 0.5 A Inductive (UR=2ms) Coded 30 VDC 1.0 A Inductive (PF0.35) Non-Coded 125 VAC 0.5 A df-60379:A1 • 08/04/09 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA:72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document /56-1190-005 and refer to the SLC Wiring Manual, document 51309. S LlteSpeedTM is a trademark and Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. _____________ K[3= We cannot cover all specific applications or anticipate all requirements. , LNINLEIINI & MRNFAC1URING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-60379:A1 • 08/04/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Models MDF-300, MMF-301 MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: S *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct kv operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 0 El f PE-11 Ccx7'J It ~ ~ SYSTEM $ SENSOR® Mini-Horns The SpectrAlerto Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. The MHR and MHW mini-horrs operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization Is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. Features 12 and 24V operation High and low volume settings Temporal and non-temporal tones Mounts to single gang back box Compatible with MDL sync module Mechanically and electrically compatible with PA400 series MiniAlortTM sounders Listing for ceiling or wall mounting Agency Listings @ <~' LISTED .,,..ED S4011 3028007 @ 0 CS1OVV 7135.1653196 FA150077 SpectrAlertO Advance Mini-Horn Specifications "Aga 99L Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini-horn shall be listed to Underwriters Laboratories Standard UL464 for tire protective signaling systems. Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync•Circuit'° Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Dimensions 4,61 x 2.9W x .45D 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: deep single-gang back box (23Adeep) Flush: Standard 4x 4-back box with single gang mud ring, which allows sufficient clearance for conduit entrance. Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 VDC 16-33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- High temporal 72 71 75 74 80 79 4 Non- Low temporal 70 69 73 72 78 77 Switch Position Sound Pattern Volume 8-17.5 Volts DC FWR 16-33 Volts DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information e . IJTIL'ie: . - MHR Mini-Horn. Red MHW Mini-Horn, White SYSTEM ©2Ol 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Vail syetense000con System Senso,. SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product lfllotfl50fl. including the latest ve,dcss at this data shoot. AVDS01500 • 3/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0196 Page 1 of 1 CATEGORY: 7135 --AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Models MHR, MHWand APA151 horns. The Model APA151 is a remote sounder intended to be connected to the alarm indicating circuit of listed duct smoke detectors. All units are for indoor use only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: APA151: Regulated 24 VDC Operational 16-33 Volts, 30mA MHR and MHW: Regulated 12V DC/FWR and 24V DC/FWR Operational 8-17.5 and 16-33 Volts, 18mA at 12V and 30mA at 24V Audibility: MHR and MHW Tones 1, 2, 3 & 4 are Public Mode at 24V DC/FWR Tone 3 is Public Mode at 12V DC Tones 1, 2 & 4 are Private Mode at 12 V DC Tones 1, 2, 3 & 4 are Private Mode at 12V FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Models MHR and MHW are listed as an audible signal appliance for use with separately listed compatible fire alarm control units. Model APA151 is listed as an accessory horn for use with separately listed 4-wire conventional duct smoke detectors. (REF: 3240-1653:119) Refer to manufacturer's Installation Manual for details. 03-15-07 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division