HomeMy WebLinkAbout6400 SURFSIDE LN; ; FPC2017-0315; Permito-l'o-wo 4 1 PERII"fltT REPORT F4irieiBeiini"ti Print Date: 08/15/2022 Job Address: 6400 SURFSIDE IN, CARLSBAD, CA 92011 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track 14: Valuation: $291,571.19 Lot 14: Occupancy Group: Project 14: #of Dwelling Units: Plan 14: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 14: Plan Check 14: Project Title: Description: CARLSBAD SEAPOINTE RESORT - CELL DIALER UPGRADE (ALARM) Applicant: LOW VOLTAGE INTEGRATED SYSTEMS KYLE ARGUIJO 1090JOSHUA WAY, 14 STE A VISTA, CA 92081-7800 (760) 598-4110 Permit No: FPC2017-0315 Status: Closed - Finaled Applied: 10/30/2017 Issued: 12/01/2017 Finaled Close Out: 04/13/2021 Final Inspection: INSPECTOR: Fieri, Dominic FPContractor: LOW VOLTAGE FIRE INC 1090 JOSHUA WAY, 14 UNIT A VISTA, CA 92081-7800 (760) 598-4110 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FIRE ALARM SYSTEM SUBMITTAL L wáItc,9re tnt9rat syst 49 ms FIRE ALARM 0 SOUND • DATA • MEDIA I SECURITY* CCTV ACCESS CONTROL FIRE ALARM SYSTEM CARLSBAD SEAPOINT RESORT CELL DIALER UPGRADE 6400 SURFSIDE LANE CARLSBAD, CA 92008 FPC20I7-0315 6400 SURFSIDE LN LOW VOLTAGE INTEGRATED SYSTEMS, INC. 1090 JOSHUA WAY, STE A VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax info@sdlvis.com License: C10, C16 # 791832 S PHONE: (760) 598-4110 FAX: (760) 598-4107 La wVoltage integrated systems MATERIAL LIST PART DESCRIPTION MANUFACTURER TG7FS CELL DIALER TELGUARD NMM-1 COP MONITOR MODULE NOTIFIER S . Low Voltage Integrated Systems, Inc. 1930 Watson Way, Ste L • Vista, California 92081 FIRE • SECURITY • CCTV • ACCESS CONTROL • SOUND • MEDIA LICENSE NO. CIO, C16#791832 email: info @ sdlvis.com TG =7FS CO V" M U NHCAT O LTE-A _t i P/N:TG7LAF0I COMMERCIAL FIRE PRODUCT FEATURES Certified for use on the AT&T LTE network for long, sunset- free installation. Meets UL 864 requirements for sole, primary or backup path communications. Minimizes false alarms by providing dual paths for self-tests. ? Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LIE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LIE-A can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-A, the monthly communications bill decreases. TELGUARD By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-A because of the new sixty minute supervision mode. The TG-7FS LIE-A can also be installed as a backup path and upgraded to sole path at a later date. Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACID 12, ACID 35, ACID 50, ACID 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. UL Listings Commercial Fire 864 Control units & accessories for fire alarm systems Commercial Burglary 365 Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems ULC Listings S545 • Canadian household fire warning systems S304 • Canadian commercial burglary alarm systems C0123 • Canadian household burglary alarm systems For the most current product specifications and UL Listings visit www.Telguard.com, TELGUARD TG=7FS LTE-A A C C Y, N U N I CA T 0 P L Telguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE • Suite 300 Atlanta, GA 30339 • USA 800-229-2326, Option 5 • www.Telguard.com • Copyright 9)2017 Telular Corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of I CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju©telular.com DESIGN: Models TG7LAA02, *TG7LA001 *TG7LM0I TG7LA002, *TG7LAF0I TG7LAF02, and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model *TG7LAF0I TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 10-03-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Monitor Modules DN-6999:C NMM-100(A), NMM.100P(Ai/ N OTI F I E R® ), NZM-100(A), and NDM.100(A) for FireWarden Series Panels by Honeywell General Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-100(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4' [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-100P(A) is a miniature monitor module a mere 1.3' (3.302 cm) H x 2.75" (6.985 cm) W x 0.5° (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. N MM-I 00(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel, Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/lRFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2, 01 —50 on FireWarden-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. lfl0MW : -- -°--- r—. •,. • . !'T' L. NMM-100(A) (Type H) NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4" (10.16 Cm) square x 2.125" (5.398 cm) deep box. DN-6999:C • 10/06/2010 - Page 1 of 4 NMM..IOOP(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) Immunity. Tinned, stripped leads for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2, 01 —50 on FireWarden-50. 15 0 1 ADDRESS 0 11 4 '°65 I LOOP C: TENS ONES The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. NMM-1 OOP(A) NMM-100P(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. NMM-IOOP(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). NMM-IOOP(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0,65° (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. NZM4 00(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address:, 01 - 99 on FireWarden- 100-2, 01 —50 on FireWarden-50. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. NZM.100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.91K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 40 (10.16 cm) square x 2.125° (5.398 cm) deep box. Page 2 of 4— DN-6999:C • 10/06/2010 NDM-100(A) Dual Monitor Module . The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM-100(A) provides two Style B (Class 8) /DC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 320 to 120°F (00 to 490C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 2.1250 (5,398 cm) deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-1 00(A) is set to address '26", then it will automati- cally assign Itself to addresses "26" and "27". . NOTE: "Ones" addresses on the NDM- 100(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and - 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4(10.16cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is Intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 FM Approved CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-100) MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100) Product Line Information NOTE: "A' suffix indicates ULC-listed model. NMM-100(A): Monitor module. NMM-100P(A): Monitor module, miniature. NZM-1 00(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. DN-6999:C • 10/06/2010 - Page 3 of 4 Notifiei® and FireWarden® are registered trademarks and FireWatch" is a trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. INEMIN &MANUMEIURINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6999:C • 10/06/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0230 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: ModelslNMM-IOOPI NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules; and *NzM.1006 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 S 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division