HomeMy WebLinkAbout1645 CHESTNUT AVE; ; FPR2018-0086; PermitI11 - uiuie1.er1mii. Print Date: 07/27/2022 Job Address: 1645 CHESTNUT AVE. CARLSBAD, CA 92008-2614 Permit Type: FIRE-Construction Residential Work Class: Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2018-0086 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 03/26/2018 Issued: 04/17/2018 Finaled Close Out: 10/01/2019 Final Inspection: INSPECTOR: Salcedo, Felix Workman, Carisa Project Title: Description: OZAKI RESIDENCE -NEW SPRINKLER SYSTEM INSTALLATION FOR SFD Applicant: WESTERN STATES FIRE PROTECTION TRAVIS BODEN 1589 W 9TH ST UPLAND, CA 91786-5666 (909) 294-9434 FPContractor: WESTERN STATES FIRE PROTECTION 3720 INDUSTRY AVE, # STE 107 LAKEWOOD, CA 90712-4135 (562) 279-0770 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $121.00 FIRE NFPA 13D Single Family System (Plan Review) $239.00 Total Fees: $360.00 Total Payments To Date: $360.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov No. 143 C) CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Ozaki Residence SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 1645 Chestnut Ave CITY: Carlsbad PHONE: ( 714 ) 533-7967 (Western States Fire Protection Co.) FAX NUMBER: Largest Building (ft.2): Sprinkled? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Chestnut Ave west of Valley Street TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 64 PSI Hydrant Number (if applicable):H60817 Elevation of test: 182 Feet Main Size: 16 INCH Pressure Zone: 330 Feet Date/Ti meof Test: Pitot Tube Reading PSI Corresponding Flow: GPM Total Flow: 6,975 GPM Residual Pressure 20 PSI Atpeakdemand, this water system is capable of providing a fire flow discharge at 20 psi of 6,975 gpm. There was no specific requestforfireflowfrom the Client or Fire Department. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: Jenrii.fer R. Mael, P.E. Eng. Lic. No. (if applicable): C69606 Signature 61 Date: 03/16/2018 # + Legend Y\ \ \ \ Z \ V Pipe ZONE 01 0 330 Fire Flow Test Location H60817 Project Site * ft .. - oc 2 Ozaki Residence 1645 Chestnut Ave - Fire Flow Analysis Hydraulic Calculations for Project Name: OZAKI RESIDENCE Location: 1645 CHESTNUT AVE, CARLSBAD, CA, Drawing Name: floor plan.cad Design Remote Area Number: 2 Remote Area Location: MASTER SUITE Occupancy Classification: Residential Density: 0.05gpm/ft2 Area of Application: 200ft2 (Actual 200ft2) Coverage per Sprinkler: 256ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 2 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: I Type: 5.00 at Node: 53 Type: Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 31.35 @48.002 Type of System: Volume of Dry or PreAction System: N/A Calculation Date: 3/20/2018 Allowance at Source Hose Name of Contractor: Address: Phone Number: Name of designer: PHILLIP DELACRUZ Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Right: N/A © M.E.P.CAD, Inc. AutoSPRlNK 2018 04.0.3.0 2 3/20/201812:55:32 Page 1 13500 1350 2700 405, 10800 12150 5400 8100 6750 9450 Flow - gpm ,© M.E.P.CAD, Inc. MM AutoSPRINK 2018 04.0.3.0 3/20/2018 12:55:34 Paçe 2 0 5C Job Name: OZAKI RESIDENCE Remote Area Number: 2 100- 30 20 6C iL 8C 7c 9C Water Supply Summary Sheet Node: 1 vailabIe Supply Static Pressure 57.600 M1.35 @ 57.598 - 1 35 48.002 NNS - System demand cue 0020.000 T'IlIIIIIII 111111111 IllIllill 111111111 I I II 11111 I I I I I I I I I I I I I I I I Hydraulic Graph N 1.85 Date: 3/20/2018 13500 10800 12150 5400 8100 6750 9450 Flow - gpm (&© M.E.P.CAD, Inc. Fill AutoSPRINK 2018 04.0.3.0 3/20/2018 12:55:34 PaQe 3 0 40 U) 0 50 Job Name: OZAKI RESIDENCE Remote Area Number: 2 100- 90 80 70 60 30 20 ig B.O.R Summary Sheet :Available Supply Static Pressure 57.600 6.35 @ 57.598 - E!635@21.637 6975.00 @ 20.000 System demand curve fljIIHIIIIIIIIIIII IIIIIIII IllIllIll II I 111111 II 11111111 I I I I I I I Hydraulic Graph N 1.85 Date: 3/20/2018 j Summary Of Outfiowing Devices Job Number: 1 Report Description: Residential (2) Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Hose 53 5.00 5.00 0 22.211 t' Sprinkler 102 13.00 13.00 4.9 7.039 Sprinkler 104 13.35 13.00 4.9 7.420 c. Most Demanding Sprinkler Data ,,©M.E.P.CAD, Inc. AutoSPRINK2O18v14.0.3.0 3/20/2018 12:55:36 Page Job Name: OZAKI RESIDENCE Remote Area Number: 2 Date: 3/20/2018 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 57.600 20.000 6975.00 57.598 31.35 48.002 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -3 Supply 48.002 31.35 53 3-3 Hose 22.211 5.00 Hos 102 91 Sprinkler 7.039 13.00 104 91 Sprinkler 7.420 13.35 4 0. 35.788 8 -3 25.675 10 9-6 7.052 13 9-6 7.445 14 9-6" 7.686 34 9-6' 17.740 54 -3' 25.649 55 3-3' 22.222 61 4-6' 21.637 63 9-6" 19.258 ,© M.E.P.CAD, Inc. AutoSPRINK 2018 04.0.3.0 3/20/2018 12:55:38 Pane 5 Job Name: OZAKI RESIDENCE Remote Area Number: 2 Date: 3/20/2018 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a ngi" "lu. Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 102 9' 4.9 13.00 1 (See Notes) 6" 150 7.039 Route I Sprinkler, E(7') 7' 0.030666 -0.217 10 9-6" 13.00 1.1010 7-6' 0.230 10 9-6" 1 (See Notes) 13'-8" 150 7.052 E(7) 0.030666 14 9'-6" 13.00 1.1010 20-8" 0.634 14 9-6' 13.35 1 (See Notes) 61'9" 150 7.686 Flow (q) from Route 2 E(7'), 4T(5) 27' 0.113300 34 9-6" 26.35 1.1010 88-9' 10.054 34 9-6' 11/4 (See Notes) 28'3" 150 17.740 T(6'), E(8) 14' 0.035907 63 9'-6" 26.35 1.3940 42'-3" 1.518 63 9-6" 11/4 (See Notes) 150 19.258 CV, cplg(1'), B.O.R 1' 0.035907 2.164 61 4-6" 26.35 1.3940 0.215 61 4-6" 1Y 1-3' 150 21.637 0.035907 0.540 55 3-3" 26.35 1.3940 1-3' 0.045 55 3-3'5.00 1% (See Notes) 6'3" 150 22.222 Flow (q) from Route 3 E(8') 8' 0.049520 2.720 54 -3' 31.35 1.3940 14-3' 0.707 54 3' 1% (See Notes) 0' 150 25.649 cplg(1') 0.025464 8 -3' 31.35 1.5980 1' 0.025 8 -3' V/2 (See Notes) 201'9" 150 25.675 EE(2'), 2E(9), WMV(-5.767) 20' 0.025464 -1.301 4 0' 31.35 1.5980 221'-9" 11.414 4 0' 1 (See Notes) 38' 150 35.788 2E(2'-4'), S 4-8' 0.255826 1.301 1 -3' 31.35 0.9950 42-8' 10.914 0.00 48.002 Hose Allowance At Source Total(Pt) Route 1 1 31.35 (,.©M.E.P.CAD, Inc. JAutoSPRINK2O18v14.O.3.O 2 3/20/2018 12:55:40 Page 6 Job Name: OZAKI RESIDENCE Remote Area Number: 2 Date: 3/20/2018 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit when applicable, are added Total ________________ (Foot) (Foot) (Foot) (psi) Friction(Pf) directly to (Pt) and shown as 104 9' 4.9 13.35 1 (See 6" 150 7.420 Route 2 ..... Notes) Sprinkler, 71 -0.217 13 9-6" 13.35 1.1010 0.032199 E(7') 7-6' 0.241 13 9-6" 1 2-6" (See 150 7.445 Notes) 14 9-6" 13.35 1.1010 0.032199 7-6" 0.241 7.686 Total(Pt) Route 2 53 3-3" 5.00 1% (See 6" J 150 22.211 Route ..... Notes) Hose 6' 1 55 3-3" 5.00 1.3940 0.001659 6-6" 0.011 22.222 Total(Pt) Route 3 ,©M.E.P.CAD, Inc. L.1 AutoSPRlNK2O18v14.O.3.O 2 3/20/2018 12:55:40 Page 7 Job Name: OZAKI RESIDENCE Remote Area Number: 2 Date: 3/20/20t8 lEquivalent Pipe Lengths of Valves and Fittings (C120 only) Value Actual Inside Diameter 4.87 Factor Value Of 100 130 140 150 I \ = Schedule 40 Steel Pipe Inside Diameter ) I Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 1l1/4 Elbow Ee2 221/2 Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,©M.E.P.CAD, Inc. JAutoSPRINK201804.0.3.0 2 3/20/2018 12:55:40 Page 8 Hydraulic Calculations for Project Name: OZAKI RESIDENCE Location: 1645 CHESTNUT AVE, CARLSBAD, CA, Drawing Name: floor plan.cad Design Remote Area Number: Remote Area Location: BED 2 Occupancy Classification: Residential Density: 0.05gpm/ft2 Area of Application: 152ft2 (Actual 152ft2) Coverage per Sprinkler: 400ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: I Type 5.00 at Node: 53 Type Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 25.02 @ 42.668 Type of System: Volume of Dry or PreAction System: N/A Calculation Date: 3/20/2018 Allowance at Source Hose Name of Contractor: Address: Phone Number: Name of designer: PHILLIP DELACRUZ Authority Having Jurisdiction: Notes Automatic peaking results Left: N/A Right: N/A M.E.P.CAD, Inc. AutoSPRlNK 2018 04.0.3.0 1 3/20/201812:54:41 Page 1 13500 9350 2700 405f: 10800 12150 5400 8100 6750 9450 Flow - gpm ) &@ M.E.P.CAD, Inc. IN AutoSPRINK 2018 04.0.3.0 3/20/2018 12:54:44 Page 2 Hydraulic Graph N 1.85 Date: 3/20/2018 Water Supply Summary Sheet Node: 1 Static Pressure 57.600 5.02 @ 57.599 5.0242.668 System demand cue 00@20.000 ,WUil!IIllIIII 111111111 111111111 111111111 I liii liii 11111 I I I I I I I I I I I I I go 80 70 30 20 10 Job Name: OZAKI RESIDENCE Remote Area Number: 1 100 60 (I) 50 a. 40 13500 10800 12150 5400 8100 6750 9450 Flow - gpm 1&©M.E.P.CAD, Inc. AutoSPRINK2018v14.0.3.0 3/20/2018 12:54:44 Pacje3 Job Name: OZAKI RESIDENCE Remote Area Number: 1 100- 70 60 40 30 20 9C 80 1E Summary Sheet vaiIable Supply Static Pressure 57.600 0.02 57.599 0.02 24.280 6975.0020.000_____________ System demand curve U!IIIIIII 11111111 111111111 111111111 III 111111 I I I I I I I I I I I I I Hydraulic Graph N 1.85 Date: 3/20/2018 ~flgjSummary Of Outfiowing Devices Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) Hose 53 5.00 5.00 0 24.836 Sprinkler 123 20.02 20.02 4.9 16.700 Q Most Demanding Sprinkler Data Job Number: 1 Residential (1) ©M.E.P.CAD, Inc. 3,1 AutoSPRlNK2018v14.0.3.0 3/20/2018 12:54:45 Page Job Name: OZAKI RESIDENCE Remote Area Number: I Date: 3/20/2018 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 57.600 20.000 6975.00 57.599 25.02 42.668 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes -3 Supply 42.668 25.02 53 3-3 Hose 24.836 5.00 Hos 123 9. Sprinkler 16.700 20.02 4 0. 34.173 8 -3 28.050 34 9-6 21.073 54 -3' 28.033 55 3-3' 24.847 60 9-6" 16.995 61 4-6" 24.280 63 9-6" 21.986 (,© M.E.P.CAD, Inc. AutoSPRlNK 2018 04.0.3.0 3/20/2018 12:54:48 Paqe 5 Job Name: OZAKI RESIDENCE Remote Area Number: I Date: 3/20/2018 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P0 and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 123 9' 4.9 20.02 1 (See Notes) 6" 150 16.700 Route I ..... Sprinkler, E(7') 7' 0.068193 -0.217 60 9-6" 20.02 1.1010 7-6" 0.511 60 9'-6" 1 (See Notes) 37'10" 150 16.995 E(7'), 31(5) 22' 0.068193 34 9-6' 20.02 1.1010 59-10" 4.078 34 9'-6" 11/4 (See Notes) 28'-3" 150 21.073 T(6'), E(8') 14' 0.021612 63 9'-6" 20.02 1.3940 42-3" 0.914 63 9-6" 1Y4 (See Notes) 5' 150 21.986 CV, cplg(1'), B.O.R , 0.021612 2.164 61 4'-6" 20.02 1.3940 6' 0.129 61 4-6" 11/4 1-3" 150 24.280 0.021612 0.540 55 3-3" 20.02 1.3940 1-3" 0.027 55 3-3" 5.00 11/4 (See Notes) 6'3" 150 24.847 Flow (q) from Route 2 E(8') 8' 0.032642 2.720 54 -3' 25.02 1.3940 14-3" 0.466 54 -3' 1% (See Notes) 0' 150 28.033 cplg(1') -1.70 .016785 8 -3' 25.02 1.5980 0.017 8 -3' 1% (See Notes) 201'9" 150 28.050 EE(2'), 2E(9'), WMV(-3.702) 20' 0.016785 -1.301 4 0' 25.02 1.5980 221-9" 7.424 4 0' 1 (See Notes) 38' 150 34.173 2E(2'-4"), S 4-8" 0.168631 1.301 1 -3' 25.02 0.9950 42-8" 7.194 0.00 42.668 Hose Allowance At Source Total(Pt) Route I 1 25.02 53 3-3" 5.00 (See Notes) 6" 150 24.836 Route 2 ..... Hose T(6') 6' 0.001659 55 3-3" 5.00 1.3940 6-6' 0.011 24.847 Total(Pt) Route 2 © M.E.P.CAD, Inc. AutoSPRINK 2018 04.0.3.0 1 3120/2018 12:54:50 Page 6 Job Name: OZAKI RESIDENCE Remote Area Number: I Date: 3/20/2018 lEctuivalent Pipe Lenaths of Valves and Fittinas (C120 onIv Value Actual Inside Diameter 4.87 Value Of C 100 130 140 150 ( \ Factor Schedule 40 Steel Pipe Inside Diameter ) I Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111/4 Elbow Ee2 221/2 Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap /,©M.E.P.CAD, Inc. JAutoSPRlNK2018v14.O.3.0 1 3/20/2018 12:54:50 Page 7 Hydraulic Calculations for Project Name: OZAKI RESIDENCE Location: 1645 CHESTNUT AVE, CARLSBAD, CA, Drawinq Name: floor plan.cad Design Remote Area Number: 3 Remote Area Location: GREAT ROOM Occupancy Classification: Residential f~'419\ t2o (S —oO (o Calculation Date: 3/20/2018 Density: 0.05gpm/ft2 Area of Application: 125ft2 (Actual 125ft2) Coverage per Sprinkler: 256ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 2 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: I Type 5.00 at Node: 53 Type Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 31.00 @49.111 Type of System: Volume of Dry or PreAction System: N/A Allowance at Source Hose Name of Contractor: Address: Phone Number: Name of designer: PHILLIP DELACRUZ Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Right: N/A M.E.P.CAD, Inc. Ill AutoSPRINK 2018 04.0.3.0 3 3/20/201812:56:10 Page 1 13500 q350 2700 4050 10800 12150 5400 8100 6750 9450 Flow - gpm J AutoSPRINK 2018 04.0.3.0 3/20/2018 12:56:12 Paqe2 ,© M.E.P.CAD, Inc. 0 40 Job Name: OZAKI RESIDENCE Remote Area Number: 3 100- Me 30 8C 7C 9C Water Supply Summary Sheet Node: 1 - Static Pressure 57.600 31.00 @ 57.598 1.0049.111- System demand curve - 00@20.000 _____ _______ 111111111 111111111 I II 11111111 II I I I I I I I I I I I I I I I I Hydraulic Graph N 1.85 Date: 3/20/2018 13500 9350 2700 , 10800 12150 5400 8100 6750 9450 Flow - gpm Date: 3/20/2018 Me 80 70 - 40 30 20 10 Job Name: OZAKI RESIDENCE Remote Area Number: 3 100 — B.O.R Summary Sheet wailable Static Pressure 57.600 6.00 @ 57.598 T26.00@23.222 6975.0020.000______________ System demand cue TIU'IIIIIIIII 111111111 111111111 I!II!IIII III liii liii III I I I I I I I I I I Hydraulic Graph N 185 I&© M.E.P.CAD, Inc. OR AutoSPRINK 2018 04.0.3.0 3/20/2018 12:56:12 Paqe 3 Summary Of Outfiowing Devices Job Number: 1 Report Description: Residential (3) Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Hose 53 5.00 5.00 0 23.795 C> Sprinkler 110 13.00 13.00 4.9 7.039 Sprinkler 111 13.00 1 13.00 1 4.9 1 7.039 c Most Demanding Sprinkler Data , © M.E.P.CAD, Inc. AutoSPRINK 2018 04.0.3.0 3/20/2018 12:56:13 Page 4 Job Name: OZAKI RESIDENCE Remote Area Number: 3 Date: 3/20/2018 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 57.600 20.000 6975.00 57.598 31.00 49.111 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -3' Supply 49.111 31.00 53 3-3" Hose 23.795 5.00 Hos 110 19 Sprinkler 7.039 13.00 111 19 Sprinkler 7.039 13.00 4 0' 37.119 8 -3' 27.244 24 19-6' 7.052 25 19-6' 7.420 26 19-6" 7.052 35 9-6" 19.237 54 -3' 27.219 55 3-3" 23.806 61 4-6' 23.222 ,,© M.E.P.CAD, Inc. JAutoSPRlNK 2018 04.0.3.0 3/20/2018 12:56:16 Paqe 5 Job Name: OZAKI RESIDENCE Remote Area Number: 3 Date: 3/20/2018 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PO and shown as a nggativ )'alus. Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pt) 110 19 4.9 13.00 1 (See Notes) 6" 150 7.039 Route I Sprinkler, E(7') 7' 0.030666 -0.217 24 19-6" 13.00 1.1010 7-6' 0.230 24 19-6' 1 (See Notes) 7' 150 7.052 T(5') 0.030666 25 19-6" 13.00 1.1010 12' 0.368 25 19-6" 13.00 1 (See Notes) 34'8" 150 7.420 Flow (q) from Route 2 4E(7') 0.110552 4.335 35 91-61,26.00 1.1010 67-8" 7.482 35 9-6" 11/4 (See Notes) 32' 150 19.237 E(8) 14 0.035036 63 9-6" 26.00 1.3940 46' 1.611 63 9-6" 1Y4 (See Notes) 150 20.848 CV, cplg(1'), B.O.R 1' 0. 035036 2.164 61 4-6" 26.00 1.3940 0.210 61 4-6" 11/4 1-3" 150 23.222 0.035036 0.540 55 3-3" 26.00 1.3940 1-3" 0.044 55 3-3" 5.00 11/4 (See Notes) 6'-3" 150 23.806 Flow (q) from Route 3 E(8') 8' 0.048510 2.720 54 -3' 31.00 1.3940 14-3" 0.692 54 -3' 1% (See Notes) o' 150 27.219 cplg(1') 1' 0.024944 8 -3' 31.00 1.5980 1 ' 0.025 8 -3' 11/2 (See Notes) 201'9" 150 27.244 EE(2'), 2E(9'), WMV(-5.645) 20' 0.024944 -1.301 4 0' 31.00 1.5980 221-9" 11.176 4 o' 1 (See Notes) 38' 150 37.119 2E(2'-4"), S 4-8' 0.250605 1.301 1 -3' 31.00 0.9950 42-8" 10.691 0.00 49.111 Hose Allowance At Source Total(Pt) Route 1 1 31.00 (,,©M.E.P.CAD, Inc. )iAutoSPRINK 2018 v14.0.3.0 3 3/20/2018 12:56:18 Page 6 Job Name: OZAKI RESIDENCE Remote Area Number: 3 Date: 3/20/2018 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) __________ Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total _________________ Node 2 (Foot) Actual ID Length (psi) (Foot) (Foot) Friction(Pf) directly to (Pf) and shown as a negative value. 111 19' 4.9 13.00 1 (See 150 7.039 Route 2 ..... Notes) Sprinkler, -0.217 26 19-6" 13.00 1.1010 0.030666 E(7') 7-6" 0.230 26 19-6" 1 (See 150 7.052 5. Notes) 25 19-6" 13.00 1.1010 0.030666 12' 0.368 7.420 Total(Pt) Route 2 53 3-3" 5.00 11/a (See 6" 150 23.795 Route 3 ..... Hose 6' Notes) 55 3-3" 5.00 1.3940 0.001659 6-6" 0.011 23.806 Total(Pt) Route 3 © M.E.P.CAD, Inc. J AutoSPRINK 2018 v14.0.3.0 3 3/20/2018 12:56:18 Page 7 Job Name: OZAKI RESIDENCE Remote Area Number: 3 Date: 3/20/2018 lEquivalent Pipe Lengths of Valves and Fittings (C=120 only) I IC Value Multiplier I I I Actual Inside Diameter 4.87 Factor Value Of 100 130 140 150 ( \ = Schedule 40 Steel Pipe Inside Diameter ) I Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111/40 Elbow Ee2 221/20 Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PlV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,©M.E.P.CAD, Inc. IN AutoSPRINK 2018 v14.0.3.0 3 3/20/2018 12:56:18 Page 8 FCSD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC — COPPER — STEEL HANGER 510 Fastener SIZE 3/4 2.125 1 2.312 11/4 3.170 11/2 3.400 2 4.010 21/2 4.320 3 5.320 SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTING/APPROVAL - 203 - EX 4231, EX 2551 LMM FUNCTION - Support horizontal piping: 3/4" -3" CPVC, Copper or Steel. Size 3/4" - 2" provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS - UL Listed per NFPA 13 in WOOD: 3/4" - 3" CPVC pipe - #905 screw - no pre-drill. 3/4" - 2" Steel and Copper pipe - 1/4"xl1/2" lag screw - no pre-drill. in STEEL - mm. 18 GA. 3/4" - 3" CPVC, Copper or Steel pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. CAN ALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap Specific AFCON products are exclusively designed to be compatible ONLY with other A FCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCONwiII NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 12/11 IAc!n P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 511 CPVC - COPPER SIDE MOUNT HANGER Side View - For Drawings Below Li SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - c®us ., 203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping - CPVC or Copper. Stabilize vertical piping. INSTALLATION - Per these instructions Hanger - Wood Stud including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on vertical mounting surface. V's FASTENERS - UL Listed per NFPA 13. in WOOD: 3/4" - 2" CPVC pipe - #905 screw - no pre-drill. 3/4" - 2" Copper pipe - #905 screw - no pre-drill. inSTEEL - min. 18 GA. 3/4" - 2" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" -2" Copper pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw included - 5/16" hex head. I' ORDERING - Part # and pipe size. Hanger - Metal Stud Specific 4 FCOAT products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCONwitl NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or orofit. when non-AFCONnrnducts have hem or ore nsrs[ 9/08 AFCSD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 513 CPVC — STEEL — COPPER HANGER T-Ts,n seer SIZE - SYSTEM PIPE: 3/4" thru 2" pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTING/APPROVAL - c®us usm 203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping - CPVC, Copper or Steel. Tab up = Hanger. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R and 13D on and CPVC manufacturers instructions. Install on vertical mounting surface. FASTENERS - UL Listed per NFPA 13. in WOOD: 3/4" - 2" CPVC pipe - #905 screw - no pre-drill. 3/4" - 2" Copper pipe - #905 screw - no pre-drill. 3/4" - 2" Steel pipe - 1/4"xl 1/2" lag screw - no pre-drill. FEATURES * Offset edge eliminates abrasion. * Required AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. Spccifie .4FCONproducls are exclusively designed to be compatible ONLY with other AFCONproducts including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. ,4FCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. D1 3/08 V .r/,A 'Zy. ALA ; P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 CPVC — COPPER STEEL OFFSET HANGER SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized.. LISTING/APPROVAL - umo 203 - EX 4231, EX 2551 #906 PATENT - No. 6,648,278. FUNCTION - Support horizontal piping: 3/4" -3" CPVC or Copper. Support horizontal piping: 3/4" - 2" Steel. Size 3/4" - 2" provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Stabilize vertical piping. INSTALLATION - Per these instructions ted including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Lis , Install on horizontal or vertical mounting surface. Snap over pipe then squeeze strap back allowing pipe to slide freely. When #905 threads are exposed in wood, install #906 backing nut. FASTENERS - UL Listed per NFPA 13 WOOD - 3/4" - 3" CPVC pipe - #905 screw- no pre-drill. 3/4" - 2" Copper pipe - #905 screw- no pre-drill. 3/4" - 2" Steel pipe - 1/4"xl 1/2" lag screw - no pre-drill. Thru 5/8" gypsum board - 1/4" x 2" lag screw. STEEL — mm. 18 GA. - 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Steel pipe - 1/4" or #14 Tek Screw. CONCRETE: Required minimum load each fastener = 5(wt)+2501bs. 2 FEATURES * 1 1/2" Offset - loose fit allows pipe to slide. * 3/4" and 1" pipe size made with common center-line. * Patented design for superior strength. * Offset edge eliminates abrasion. * AFCON#905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. AFCON #906 backing nut sold separately. Listed Restraint 3/4" thru 2" Specific .4FCONproducts are exclusively designed to be compatible ONLY with other A FCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, pails or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 9/08 T 1.00 [OV P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 515 cPvc DOUBLE OFFSET HANGER SIZE-SYSTEM PIPE: 3/4" and 1" MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTING/APPROVAL - 203 - EX 4231 USTED PATENT - No. 6,702,236 FUNCTION - Support/Restrain horizontal CPVC piping. INSTALLATION - Per these instructions including NPFA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS - UL Listed per NFPA 13. WOOD: 3/4" and 1" #904 screw - no pre-drill. FEATURES * Double 1 1/2" offset * Center line matches AFCON #514. * 3/4" and 1" pipe size have common center-line. * Offset edge eliminates abrasion. * Required AFCON #904 screw included - 3/8" hex head. ORDERING - Part # and pipe size. Specific .4FC0N products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER- AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 3/08 .!11AA r' 52 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 904 C.P.V.C. SCREW For use with U.L. Listed AFCON Products #515 and 519. 3/8" Hex Head 905 C.P.V.C. SCREW For use with U.L. Listed AFCON Products #510, 511, 512, 513 and 514. 5/16" Hex Head 906 Pal Nut [a For use with AFCON #905 screw as required by product installation. oj Example: See #514 engineering sheet 1/08 Bulletin 006 Rev. K February 2017 Reliable POLO Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler cULus Listed Product Features cULus Listed as Residential Sprinklers Push-On cover plate installation Low water flow requirements Product Description Model RFC3O II, F.. Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. Model RFC30, RFC43, and RFC49 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC58 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link op- erating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and should be used with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and should be used with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC43, and RFC49 sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC cover plates are available in a variety of finishes as listed in Table H. In addition, Model RFC cover plates may be ordered as either traditional solid cover plates or perforated cover plates. Model RFC49 Model RFC58 / Solid Perforated Model RFC Cover Plate Sprinkler Model Nominal K-Factor Max. Coverage Area Sprinkler Identification gpm/psi1'2 (1/min/bar111 ft x ft (m x m) Number (SIN) RFC30 3.0 (43.2) 14x 14(4.3x4.3) RA0611 RFC43 4.3(62) 20x20(6.1 x6.1) RA0612 RFC49 4.9 (70.6) 20x20(6.1 x6.1) RA0616 RFC58 5.8(84) 20x20(6.1 x6.1) RA0613 www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 3.0 (43.2 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast-response Mm. Spacing: 8 ft. (2.4 m) Temperature Rating Material Specifications 165°F (74°C) sprinkler Thermal Sensor: Nickel Alloy Solder Link 135°F (57°C) cover plate Sprinkler Body: Brass Alloy Levers: Bronze Alloy Cover Plate Yoke: Brass Alloy Model RFC cover plate Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrench Towers: Copper Alloy Model FC Pins: Stainless Steel Deflector: Bronze Alloy Listings and Approvals Cup: Steel cULus Listed Model RFC30 Sprinkler Components and Dimensions I 2-5/16° (58 mm) Threads Dia. Body1 Cup - 1-3/4° (44 mm) +/- 1/4" (6 mm) Fusible Link Nominal face of fitting to ceiling Deflector (retracted) $ Pin (extended) II Deflector (extended) "A 3/16"(5mm) Model RFC Cover Plate -' I 3-5/16° (84 mm) Dia Ceiling Model RFC30 Sprinkler Hydraulic Design Criteria Table B Minimum Flow and Residual Pressure Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 12x12 9 9,0 (3.6 x 3.6) (34) (0.62) 14x14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. K Page 2 of 7 February 2017 Heliabld www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.3 (62 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast-response Mm. Spacing: 8 ft. (2.4 m) Temperature Rating Material Specifications 165°F (74°C) sprinkler Thermal Sensor: Nickel Alloy Solder Link 135°F (57°C) cover plate Sprinkler Body: Brass Alloy Levers: Bronze Alloy Cover Plate Yoke: Brass Alloy Model RFC cover plate Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrench Towers: Copper Alloy Model FC Pins: Stainless Steel Deflector: Bronze Alloy Listings and Approvals Cup: Steel cULus Listed Model RFC43 Sprinkler Components and Dimensions _____ 2-5/16(58mm) Threads —N_ Body Cup— Tower •••• I r I 1-3/4 (44 mm) +1- 1/4" (6 mm) Fusible LinkLink Nominal face of filling to ceiling Deflector (retracted) \•\\\\\ Pin (extended) j- - - Deflector (extended) Model RFC Cover Plate 3-5/16 (84 mm) Dia. - 3/16" (5 mm) Ceiling Model RFC43 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 12x12 12 7.8 (3.6 x 3.6) (45) (0.54) 14x14 13 9.1 (4.3 x 4.3) (49) (0.63) 16x16 13 9.1 (4.9 x 4.9) (49) (0.63) 18x18 18 17.5 (5.5x5.5) (68) (1.21) 20x20 21 23.8 (6.1 x6.1) (79) (1.64) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. K Page 3 of 7 February 2017 www.reliablesprinkler.com Nominal face of fitting to ceiling 1-3/4" (44 mm) +1- 1/4"(6 mm) 3/16 (5 mm) Threr Body Cup lowe Fusible Li Deflector (retn Pin (extei Deflector (extend 2-5/16" (58 mm) Dia. Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.9 (70.6 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast-response Mm. Spacing: 8 ft. (2.4 m) Temperature Rating Material Specifications 165°F (74°C) sprinkler Thermal Sensor: Nickel Alloy Solder Link 135°F (57°C) cover plate Sprinkler Body: Brass Alloy Levers: Bronze Alloy Cover Plate Yoke: Brass Alloy Model RFC cover plate Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrench Towers: Copper Alloy Model FC Pins: Stainless Steel Deflector: Bronze Alloy Listings and Approvals Cup: Steel cULus Listed Model RFC49 Sprinkler Components and Dimensions LII1IC Model RFC Cover Plate 3-5/16" (84 mm) Dia. Ceiling Model RFC49 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 13 7.0 (4.9 x 4.9) (49.0) (0.48) 18x18 17 12.0 (5.5 x 5.5) (64.3) (0.83) 20x20 20 16.7 (6.1 x6.1) (75.7) (1.15) Notes: For NFFA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. K Page 4 of 7 February 2017 RCIIaIII www.reliablesprinkler.com I Technical Specifications Sensitivity Style: Flat Concealed Pendent Fast-response Threads: 1/2' NPT or ISO 7-1 R1/2 Nominal K-Factor. 5.8 (84 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) Ordinary: Mm. Spacing: 8 ft. (2.4 m) 165°F (74°C) sprinkler 135°F (57°C) cover plate Material Specifications Intermediate: Thermal Sensor: Nickel Alloy Solder Link 212°F (100°C) sprinkler Sprinkler Body Brass Alloy 165°F (74°C) cover plate Levers: Bronze Alloy Yoke: Brass Alloy Cover Plate Sealing Assembly: Nickel Alloy with PTFE Model RFC Cover Plate Load Screw: Bronze Alloy Towers: Copper Alloy Sprinkler Wrench Pins: Stainless Steel Model FC Deflector: Chrome Plated Bronze Alloy Cup: Steel Listings and Approvals cULus Listed Cover Plate Finishes (See Table H) Bottom View Model RFC58 Sprinkler Components and Dimensions 2-5/16" (58 mm) I nre Body Cup Towe Fusible Li Deflector (retra Pin (exter Deflector (extend Dia. 1-718" (48 mm) +1- 3/8" (9 mm) Nominal face of fitting to ceiling \\\\\\\ j13/16 (5 mm) Model RFC Cover Plate - I 3-5/16" (84 mm) Dia. Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria F1 Z NMI Minimum Flow and Residual Pressure 7 Max. Coverage Area() Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18x18 18 9.6 (5.5x5.5) (68.1) (0.66) 20x20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. K Page 5 of 7 February 2017 www.reliablesprinkler.com Cover Plate Finishest1 Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint') Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Installation Dimensions Recommended Mm. to Mm. to Max. Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Sprinkler Plate Diameter i n Ceiling Adjustment of Fitting to Distance below Temperature Model Model inch inch inch Ceiling1t Ceiling Rating (mm) (mm) (mm) inch inch (mm) (mm) RFC3O RFC43 RFC 3-5/16 2-5/8 1/2 1-1/2t02 1/2to1 135°F RFC49 (84) (67) (13) (38 to 51) (13 to 25) (57°C) 135°F121 RFC58 RFC 3-5/16 2-5/8 3/4 1-1/2t02-1/4 1/4to1 (57°C) (84) (67) (19) (38 to 57) (6 to 25) or 165°F(3) (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). For use with 212°F (100°C) temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F (66°C). Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a protective cap that should remain on the sprinkler until installed. The protective cap should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Model RFC series sprinklers are installed with the Model FC wrench. The use of any other wrench to installed Model RFC se- ries sprinklers is not permitted and may damage the sprinkler. Temporarily remove the protective cap during installation of the sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model FC wrench is designed to be turned with a standard 1/2" square drive. Tighten the sprin- kler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft/lb (11 to 24 N/rn). Bulletin 006 Rev. K February 2017 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30, RFC43, and RFC49 sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (380C). Model RFC58 sprinklers are available in either ordinary or in- termediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (66°C), respectively. Page 6 of 7 www.reliablesprinkler.com Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC43, RFC49, and RFC58 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603, Model RFC30 and RFC43 sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler Model (RFC30, RFC43, RFC49, RFC58) Temperature Rating Cover Plate Model RFC Temperature Rating Finish (See Table H) Sprinkler Wrench Model FC Bulletin 006 Rev. K Page 7 of 7 February 2017 Reliable www.reliablesprinkler.com Fl Res 30, 49, 58 & 76 Fl Res 30, 49, 58 & 76 Recessed Pendent I Fl Recessed Pendent I FP Fl Res 30, 49, 58 & 76 Fl Res 44&58 CCP Pendent Recessed HSW/F2 PP LOOulletjfl 135 Rev. Rel iablö Model Fl Residential Sprinklers for Design Density of .05 gpm/ft2 C 0 CO 01 I (D Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpm/Yt2 Types: Fl Res 30 Pendent Fl Res 30 Recessed Pendent/F2 Fl Res 30 Recessed Pendent/FP Fl Res 49Pendent Fl Res 49 Recessed Pendent/Fi Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendent Fl Res 58 Recessed Pendent/F1 Fl Res 58 Recessed Pendent/FP Fl Res 76Pendent Fl Res 76 Recessed Pendent/Fl El Res 76 Recessed Pendent/FP Fl Res 30 CCP Pendent Fl Res 49 CCP Pendent Fl Res 58 COP Pendent Fl Res 76 CCP Pendent Fl Res 44HSW Fl Res 44 Recessed HSW/F2 Fl Res 58 HSW Fl Res 58 HSWX KRes58HSWX Fl Res 58 HSW Recessed HSW/F2 Fl Res 44SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model El Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model Fl Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model El Res 44 SWC Sprinklers Product Description Model El Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitiv- ity glass-bulb and low profile decorative design. The Fl Res I-i Nes bb -1WX El Res 44 SWC Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attrac- tive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- tion needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflector,evenly distributing the discharged water to control a fire. Technical Data: Thermal Sensor: Soldered Element (Link) or Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: 1/2" NFl (R1/2) K-Factor: 3.0 (43.2) (Actual) - Fl Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (83.5) (Actual) - Fl Res 58 Pendent & HSW Sprinkler 7.6 (109)(Actual) - Fl Res 76 Pendent Sprinkler 4.4(63) (Actual) - Fl Res 44 HSW Sprinkler Density: Minimum 0.05 gpm/ft2 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model El Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R, or 13 2013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The Na- tional Fire Protection Association or the approving authority having jurisdiction. Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are Escutcheon*, Fl or F2, Data: the only recessed escutcheons to be used with Model El Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pen- dent sprinklers use only the Model D sprinkler Wrench; for installing Models Fl Res Recessed Pendent, COP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for in- stalling Model Fl Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 with a ceiling to deflector distance of 4" - 12". Flow arrow on deflector must point away from near wall and "Top" mark- ing must face ceiling. Type Adjustment Inch (mm) "A" Inch (mm) Face of fitting to ceiling Inch (mm) Deflector Distance below bottom of beam Inch (mm) Fl 3/4 (19.0) Mm. Recessed = 1/e (41.3) 3/8 (9.5) 13/4 (44.4) Max. Recessed =/8 (22.2) 11/8 (28.6) 1(25.4) F2 1/2 (12.7) Mm. Recessed = 1/8 (41.3) 3/8 (9.5) 1/4 (44.4) Max. Recessed = 11/8 (28.6) 7/8 (22.2) 11/4 (31.7) Note: Escutcheons Fl or F2 may be used with Model Fl Res 49, 68 & 76 Recessed Pendent Sprinkler Model Fl Res 30 Recessed Pendent I F2 ivioaeu 1-1 lies ziu, LW, ou & /b ienae nt Model Fl Res 49, 58 & 76 Recessed Pendent I Fl Fl escutcheon, 3/4" (19mm) adjustment 2 1/4 HOLE [57.2mm] 1 15/16 0/A. [49.2mm] TURN COLLAR UNTIL I X 1/2 REDUCER FACE OF FITTING TO CEILING DIMENSION: 3/8-1 1/8 (Fl ESCUTCHEON) WRENCH BOSS. - ___________________ TIGHT AGAINST SPRINKLER 318"-718" (F2 ESCUTCHEON) ADJUSTMENT ' [ 2 27/32' DIA. 722mm]P Fig. 1 Fig. 2 Technical Data: F1 Res 30 Pendent and Recessed Pendent (SIN R3511) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating I Max. Ambient Temp. Actual K Factor I Sprinkler Length I Inch (mm) OF OF I OC NPT 1/' 175 21/64" (8.2) 175 (12) 79 100 38 3.0(43.2) 2.25 (57) M. Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area (155°F1680C) (175°F/790C) Top of Deflector to Ceiling Flow Pressure Flow Pressure Ft x Ft (m x m) Spacing Ft (m) Inch (mm) Spacing Ft GPM (L/min) PSI (bar) GPM (1/mm) PSI (bar) (m) 12 x 12(3,6 x 3,6) 12(3,6) 8(30.3) 7.0 (0,48) 8(30,3) 7.0(0,48) Smooth Ceilings 1Y4 to 4(31.7 to 102) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 10 (37,8) 11(0,76) 10 (37,8) 11(0,76) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 11/4 to 1/4 (31.7 to 44.4) using F2 escutcheon 8(2,4) 16 X 16(4,91<4,9) 16(4,9) 13(49) 18.8(1,3) 13(49) 18.8 (1,3) For Ceiling types refer to NFPA 13, 13R or 13D 2. 735F003 Technical Data: Fl Res 49 Pendent and Recessed Pendent (SIN R3516) Thread Nominal Orifice Max. Sprinkler Max. I Actual Sprinkler Size Inch (mm) Pressure I Temp. Rating Ambient Temp. K Length OF °C OF °C psi (bar) I Factor I Inch (mm) ½" NPT (ii) 175 (12) 155 68 100 I 38 4.9 (70.6) 2.25 (57) (R½) 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°Fit8°C) (175°F/79°C) to Ceiling Spacing flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (Lhiin) PSI (bar) GPM (Llmin) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49) 7.0 (0,48) 13 (49) 7.0 (0,48) Smooth Ceilings 1114 to 4 (31.7 to 102) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 13 (49) 7.0 (0,48) 13 (49) 7.0 (0,48) 1 t 4(25.4 to 102) using Fl escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) 13 (49) 7.0 (0,48) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 18x 18(5,5x5,5) 18(5,5) 17(64,3) 12(0,83) 17(64,3) 12(0,83) beams 11/4 t0134 (31.7t0 4.4.4) using F2 escutcheon, 1 20 x 20(6,1 x 6,1) 20(6,1) 20 (75,7) 16.7 (1,14) 20 (75,7) 16,7(1,14) to 13/4 (25.4 to 44.4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (1550Fi8°C) (175°F/79° C) to Ceiling Spacing Flow Pressure Row Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (Llmin) PSI (bar) GPM (L/min) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 15 (57) 9.4 (0,65) 15 (57) 9.4 (0,65) Smooth Ceilings 4 to 8 (100 to 203) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(60,5) 10.6 (0,73) 16(60,5) 10.6 (0,73) 4 to 8(100 to 203) using Fl escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 17 (64,3) 12.0 (0,83) 17 (64,3) 12.0 (0,83) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 8(2,4) 18 X 18(5,5 X 5,5) 18(5,5) 19(72) 15.0 (1,0) 19(72) 15.0 (1,0) 41/4 to 8(108 to 203) using F2 escutcheon, 4 to 8(100 to 203) 20x20(6,1 x6,1) 20(6,1) 22 (83,2) 20.2 (1,4) 22 (83,2) 20.2(1,4) using Fl escutcheon Technical Data: F1 Res 58 Pendent and Recessed Pendent (SIN R3513) Max. Sprinkler I Max. Sprinkler Thread Nominal Orifice I I Pressure I I Temp. Rating I I Ambient Temp. Actual I Length Size Inch (mm) psi (bar) K Factor I I Inch (mm) OF °C OF °C 1/2" NPT ½" (13) 175 (12) 155 68 100 38 5.8 (83.5) 2.25 (57) (R½) 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°Fi8°C) (175°F/79°C) to Ceiling Spacing flow Pressure Flow Pressure Ft x Ft (mx m) Ft (m) Inch (mm) Ft (m) GPM (L.in) PSI (bar) GPM (L/min) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16 (61) 7.6 (0,53) 16(61) 7.6(0,53) Smooth Ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6 (0,53) 16(61) 7.6(0,53) 1 t 4(25.4 to 102) using Fl escutcheon. 16 X 16 (4,9 X 4,9) 16(4,9) 16 (61) 7.6 (0,53) 16 (61) 7.6 (0,53) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 10.8 (0,75) 19(72) 10.8(0,75) 1¼ to 1/4 (31.7 to 44.4) using F2 escutcheon, 1 t 1% (25.4 to 20x20(6,1 x6,l) 20(6,1) 22 (83,3) 14.4(l.0) 22 (83,3) 14.4(1,0) 44.4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D CI Technical Data: Fl Res 76 Pendent and Recessed Pendent (SIN R7618) Thread Nominal Orifice I Max. Sprinkler Max. K I I Sprinkler Pressure Temp. Rating I Ambient Temp. Length Size Inch (mm) psi (bar) I Factor Inch (mm) OF I0CIOF 3/4" NPT 17/32' (13.5) 175(12) 155 68 100 38 7.6(109) 2.25 (57) (R3/4) 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Max. Spacing (155°F80C) (175°F/79°C) Top of Deflector to Ceiling Spacing Flow Pressure Flow GPM Pressure Ft x Ft (m x m) Ft (m) Inch (mm) GPM (1-min) PSI (bar) (L/min) PSI (bar) 12x 12(3,6x3,6) 12(3,6) 21(79,5) 7.6(0,53) 21(79,5) 7.6(0,53) Smooth Ceilings 414to8(108 to 203) using F2 escutcheon. 14x 14(4,3x4,3) 14(4,3) 21(79,5) 7.6 (0,53) 21(79,5) 7.6(0,53) 4t08(100t0203) using Fl escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 21(79,5) 7.6 (0,53) 21(79,5) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 18x 18(5,5x5,5) 18(5,5) 21(79,5) 7.6 (0,53) 21(79,5) 7.6(0,53) beams 4%t08(108t0203)us- ing F2 escutcheon, 4 to 8 (100 20x20(6,1 x6,1) 20(6,1) 23 (87,1) 9.2 (0,63) 23 (87,1) 9.2(0,63) to203) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 30. 49. 58 & 76 CCP Pendent* * Not listed for corrosion resistance. - 2 5/8" [66.7mm] DIA. 2 5/16" 0/A. HOLE IN CEILING [58.7mm] CUP ri ...- 1"x112" REDUCER CUP /1 CEILING MAX 'AC1OFFITT7\IG TO FACE OF CEILING DIMENSION "A" J I COVER ADJUSTMENT I HEIGHT 3 5/16 0/A. 1J5FG04E [84.1mm] Fl RES 30, 49, 58 & 76 CCP PEND. Fig. 3 Note: The Fl Res 76 will use a 1" x Y4" reducer. CCP Cover Plate Data: Cover Adjustment CCP Height "C,, Deflector Distance below bottom Inch (mm) Inch (mm) of beam Inch (mm) 1/2 (12.7) "1/16 (24) ½(13)- 1(25.4) //6 (7.9) 3/ (19) ½ (13) - 1(25.4) Model Fl Res 30, 49, 58 & 76 FP push-on/thread-off escutcheon 2 5/8" 0/A. [66.7mm] -HOLE IN CEILING - 2 5/16" DIA. - [58.7mm] - CUP ( 1_ I - 1" X 1/2" REDUCER CEILING ____ 1 1/2" [38.1mm] MAX. \ FACE OF FITTING 1 L1 fl JJJ FACE_OF CEILING ON 1/2" [13mm] MAX] I4Y .., "h.. FP ADJUSTMENT Fl RES 49 PENDENT/FP Fig. 4 FP Escutcheon Data: "B" FP Position "A" Deflector Distance below bottom Inch (mm) of beam Inch (mm) Max. Recessed /I6(11) 1/2 (12.7) Mm. Recessed 15/16 (24) 1 (25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. 4. Technical Data: Fl Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) Thread Nominal I Max. CCP Assembly I Max. I I K I Sprinkler I Size Orifice Pressure Temp. Rating Ambient Temp. Factor Length Inch (mm) psi (bar) Inch (mm) ½"NPT (R½)21/64" (8.2) 175(12) 135 OFffC °F :J:~ 100 tCi 3.0 (43.2) 2.25 (57) Ordinary Temp. Rating Minimum Max. Coverage area Max. Spacing (155°F/680C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (1/mm) PSI (bar) Smooth Ceilings ½ to 1(13 to 25.4) using OCR. 12 X 12 (3,6 >< 3,6) 12(3,6) 8(30.3) 7.0 (0,48) 1/2 to 1(13 to 25.4) using FP escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 11(37,8) 13.4 (092) beams ½tol (13 to 25.4) using CCP. ½ to 1(13 to 25.4) using FR escutcheon. For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) Nominal Max. CCP Assembly Max . Sprinkler Thread Orifice Pressure Temp. Ambient K Length Size Inch psi (bar) Rating Temp. _ Factor Inch (mm) (mm) OF I °c OF I ½"NPT (R1/2)/16" (11) 175 (12) 135 57 100 38 4.9(70.6) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155- 8-C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (1/mm) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0 (0,48) Smooth Ceilings ½ to 1(13 to 25.4) using 14 x 14 (4,3 x 4,3) 14(4,3) 13(49) 7.0 (0,48) OCR. ½ to 1(13 to 25.4) using FR escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 14(53) 8.2 (056) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(13 to 25.4) using 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68,1) 13.5(0,93) CCP. ½ to 1(13 to 25.4) using FR escutcheon. 20x20(6,1 x6,1) 20(6,1) 20(75,7) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: Fl Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Nominal Max. CCP Assembly Max. K Sprinkler Thread Orifice I I Pressure I Temp. Rating I Ambient Temp. Length Size Inch (mm) psi (bar) Factor I Inch (mm) I OF I °C I OF °C ½" NRT (R½) 1/2" (13) 175 (12) 135 57 100 38 5.8 (83.5) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155- 80C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L,Thin) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 16 (61) 7.6 (0,53) Smooth Ceilings ½ to 1(13 to 25.4) using CCR ½ to 1 (13 to 25.4) using FR escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 16 (61) 7.6 (0,53) 16 x 16 (4,9 x 4,9) 16(4,9) 16 (61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 8(2,4) 1(13 to 25.4) using CCP. 18 x 18 (5,5 x 5,5) 18(5,5) 19 (72) 10.8 (0,75) ½ to 1(13 to 25.4) using FR escutcheon. 20x20(6,1 x6,1) 20(6,1) 22 (83,3) 14.4 (1,0) For Ceiling types refer to NFPA 13, 13R or 13D 5. Model Fl Res 44 & 58 Recessed HSW/F2 F2 escutcheon, 1/2" (13mm) adjustment Technical Data: Fl Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Thread Nominal I Max. I CCP Assembly Max. K Sprinkler Size Orifice Pressure Temp. Rating Ambient Temp. Factor Length I °C °C Inch (mm) psi (bar) I Inch (mm) 3/4' NPT (R3/4) 17/32 (13.5) 175 (12) 135 57 100 150 38 66 7.6(109) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155°F/680C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) GPM (1/m PSI (bar) Ft (m)m) 12 x 12 (3,6 x 3,6) 12(3,6) 21 (79,5) 7.6 (0,53) Smooth Ceilings 1/2 to 1(13 to 25.4) using CCP. 1/2 to 1(13 to 25.4) using FP escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 21 (79,5) 7.6 (0,53) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to (13 to 25.4) using CCP. 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 22(83,3) 8.4 (0,58) 1/2 to 1(13 to 25.4) using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 25(94,6) 10.8 (0,74) For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 44 & 58 HSW FACE OF FITTING TO -1 1/4" MIN. WALL DIMENSION -2 1/4" HOLE OIA. ':4,, [5 7.2mm] CEILING TO DEFLECTOR 1 X 1/2 REDUCER DIMENSION 15116- DIA.li___ [49.2m 2 27/32" DIA. [72.2mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. 1/2" [13mm] -H 135F606-D ADJUSTMENT Fl RES 58 & 44 HSW/F2 Fig. 5 Technical Data: F1 Res 44 HSW & HSW/F2 (SIN R3531) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Size Orifice Pressure Temp. Rating Temp. Factor Length Inch (mm) psi (bar) OFOC Inch (mm) OF °C ½" NPT (R½) 3/8"(10) 175(12) 155 175 68 79 100 150 38 I 66 4.4(63) 2.45 (62) Escutcheon, F2, Data: Face of Fitting Type Adjustment to wall Inch (mm) Inch (mm) F2 1/2(13) /16 - 11/16 (4.7-17.4) l-IvI 16(60,6) 18 (68,2) 21(79,5) 25 (94,7) 29(109,8) 22 (83,3) 22 (83,3) 26 (98,4) 31(117,4) r.1 011 7.6 (0,53) 9.7 (0,69) 13.2 (0,91) 18.6(1,28) 25.0(1,73) 14.4 (1,0) 14.4 (1,0) 20.1 (1,39) 28.6 (1,97) ,ruvu I,,I.JIIIII 16(60,6) 18 (68,2) 21(79,5) 25 (94,7) 29 (109,8) 22 (83,3) 22 (83,3) 26 (98,4) 31(117,4) 7.6 (0,53) 9.7 (0,69) 13.2 (0,91) 18.6 (1,28) 25.0 (1,73) 14.4 (1,0) 14.4 (1,0) 20.1 (1,39) 28.6 (1,97) 4 to 6 (100 to 152); ½ (13) recessed using F2 escutcheon 8(2,4) 6 to 12 (152 to 305); 1/2 (13) recessed using F2 escutcheon Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/790C) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (1/mm) Pressure PSI (bar) Flow GPM (1/mm) Pressure PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 12 (45,4) 7.5 (0,52) 12 (45,4) 7.5 (0,52) 4 to 6(100 to 152); ½ (13) recessed using F2 escutcheon 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 14(53,0) 10.2(0,71) 14(53,0) 10.2 (0,71) 16 x 16 (4,9 x 4,9) 16(4,9) 16(60,6) 13.3(0,92) 16(60,6) 13.3 (0,92) 16 x 18(4,9 x 5,5) 16(4,9) 18(68,1) 16.8 (1,16) 18(68,1) 16.8(l.16) 18 x 18(5,5 x 5,5) 18(5,5) 19(72,0) 18.7(1,29) 19(72,0) 18.7(1,29) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4(1,89) 12 x 12(3,6 x 3,6) 12(3,6) 14(53,0) 10.2 (0,71) 14(53,0) 10.2(0,71) 6t0 12 (152 to 305); ½(13) recessed using F2 escutcheon 14 x 14(4,3 x 4,3) 14(4,3) 16(60,6) 13.3 (0,92) 16(60,6) 13.3 (0,92) 16 x 16(4,9 x 4,9) 16(4,9) 17(64,4) 15.0 (1,04) 17(64,4) 15.0 (1,04) 16 x 18(4,9 x 5,5) 16(4,9) 20(75,7) 20.7 (1,43) 20 (75,7) 20.7 (1,43) 16 x 20(4,9 x6,1) 16(4,9) 23 (87,1) 27.4(1,89) 23 (87,1) 27.4(1,89) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: Nominal Max. Sprinkler Max. Sprinkler Thread Orifice Pressure Temp. Rating Ambient K Length Size Inch psi (bar) ___________ Temp. Factor Inch OF °C °F (mm) (mm) ½" NPT 1/2" (13) 175 (12) 155 68 100 38 5.8 (83.5) 2.45 (62) (R½) 175 79 150 66 Escutcheon, F2, Data: Adjustment Face of Fitting Type to wall Inch (mm) Inch (mm) F2 '/2(13) 3/16 - 11/16 (4.7-17.4) Ordinary Temp. Rating Intermediate Temp. Rating Max. Coverage area Max. Spacing (155°Fi8°C) (175°F/79°C) Top of Deflector to Minimum Ft x Ft (m x m) Ft (m) Flow Pressure Flow Pressure Ceiling Spacing fl-nRm ,. .. Inch (mm) Ft (m) 12 x 12 (3,6 x 3,6) 12(3,6) 14 x 14(4,3 x 4,3) 14(4,3) - 16 x 16 (4,9 x 4,9) 16(4,9) - 16 x 18(4,9 x 5,5) 16(4,9) - 16 x 20(4,9 x 6,1) 16(4,9) - 12 x 12(3,6 x 3,6) 12(3,6) - 14 x 14(4,3 x 4,3) 14(4,3) - 16 x 16(4,9 x 4,9) 16(4,9) - 16 x 18(4,9 x 5,5) 16(4,9) - Ceiling types refer to NFPA 13, 13R or 13D 7. Model Fl Res 44 SWC * Not listed for corrosion resistance. Trhnirl flf• F:1 Rime AA qW( iIM Rci 4 to 72 [707.60,,,,,, To I I/4 131.75.m] Mooi,,,*m .304.80mn,] F,,,,,, Of Fitting To WoII Dime,,oio,, PUSH ON COVER, THEN TURN TO ADJUST UNTIL TIGHT AGAINST WALL. X I/2 Reducer R W Hole .It mood;d [ 4 TURN COLLAR UNTIL IGHT AGAINST SPRINKLER T WRENCH 1 21132 BOSS. J5FCO7 - Fl RES 44 SWC Fig. 6 Nominal Max. Cover Max. Sprinkler Thread Orifice Pressure Temp. Ambient K Length Inch (mm) psi (bar) Rating Temp. Factor Inch (mm) OF I 0 OF I ½"NPT (R½) 3/8"(10) 175 (12) 135 57 100 I 38 4.4(63) 2.45 (62) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°Fi68°C) Top of Deflector to Ceiling Inch (mm) PSI (bar) Minimum Spacing Ft (m) Flow GPM (tJmin) Pressure 12 x 12 (3,6 x 3,6) 12(3,6) 13(49,2) 8.7 (0,60) 4t06(100to 152); ½(13) recessed using F2 escutcheon 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 14 (53,0) 10.2 (0,71) 16 x 16 (4,9 x 4,9) 16(4,9) 17(64,3) 15.0 (1,1) 16 x 18 (4,9 x 5,5) 16(4,9) 19(718) 18.7(1,13) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4(1,89) 12 x 12(3,6 x 3,6) 12(3,6) 14(52,9) 10.2 (0,71) 6t0 12 (152 to 305); ½ (13) recessed using F2 escutcheon 14x 14(4,3x4,3) 14(4,3) 15 (56,7) 11.7 (0,81) 16 x 16(4,9 x 4,9) 16(4,9) 18(68,1) 16.8 (1,16) 16 x 18(4,9 x 5,5) 16(4,9) 20 (75,6) 20.7 (1,43) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: Fl Res 58 HSWX (SIN RA3533) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Rating _____________ Temp. __________ Factor Length Identification Inch (mm) psi (bar) Inch (mm) Number (SIN) OF I°C OFIOC Bulb ½' NPT (R1/2) 1/2" (13) 175 (12) 155 175 68 79 100 150 38 5.8 (83.5) 66 2.45 (62) RA3533 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F179°C) Top of Deflector to Ceiling Inch (mm) PSI (bar) Minimum Spacing Ft (m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure 18 x 20(5,5 x 6,1) 18(5,5) 30(114) 26.8(1,85) 30(114) 26.8 (1,85) 4t06(100to 152); 1/2 (13) recessed using F2 escutcheon 8(2,4) 20x20(6,1 x6,1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 16 x 22(4,9 x 6,7) 16(4,9) 33(125) 32.4(2,23) 33(125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16(4,9) 38(144) 42.9 (2,96) 38(144) 42.9 (2,96) 14 x 26 (4,3 x 7,9) 14(4,3) 42 (160) 52.4 (3,75) 42 (160) 52.4(3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4 (2,5) 35(133) 36.4 (2,5) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9 (2,96) 38(144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16(4,9) 42(160) 52.4(3,6) 42(160) 52.4 (3,6) 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9 (4,34) 46(174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 58 HSWX (Bulb) WALL DIMENSION -1 FACE OF FITTING TO 11/16' MIN. I [31.8mm] -2 1/4" HOLE DIA. [57.2mm] [32mm] CEILING TO DEFLECTOR 1" X 1/2" REDUCER DIMENSION - 1 15/6 DIA.JJ [49.2m DIA. - [722mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. 1/2" [13mm] -H I35PGO8 ADJUSTMENT Fl RES 58 HSWX Fig. 7 ' Model KRes58 HSWX (Link Technical Data: KRes58 HSWX (RA3593) Thread Nominal Max. Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure emp. Factor Length Identification Inch (mm) Inch (mm) Number (SIN) Link 1/2 NPT (R1/2) 1/2" (13) psi (bar)f00F' 175(12) 038 5.8(83.5) 2.45 (62) RA3593 _______ Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (165°F174°C) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (1/mm) Pressure PSI (bar) 18 x 20(5,5 x 6,1) 18(5,5) 29(109) 25(1,72) 4t06(100to 152); ½ (13) recessed using 1-2 escutcheon 8(2,4) 20 x 20 (6,1 x 6, 1) 20(6,1) 30(114) 26.8(1,85) 16 x 22 (4,9 x 7,3) 16(4,9) 33(125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16(4.9) 38 (144) 42.9 (2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42 (160) 52.4 (3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4 (2,5) 610 12 (152 to 305); ½ (13) Recessed using F2 escutcheon 16 x 22 (4,9 x 6,7) 16(4,9) 38 (144) 42.9 (2,96) 16 x 24(4,9 x 7,3) 16(4,9) 42 (160) 52.4(3,6) 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model Fl Res 30, 49, Fl Res 58, Fl Res 76 and Fl Res 44 Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guide- lines and the applicable installation standard. Deflector- to-ceiling distance listing shall be 1" to 8" maximum, only for Fl Res 49. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish- specify]. Resi- dential pendent sprinklers shall be Reliable Model Fl Res 30,49 & 58, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 49 & 58 Recessed Pendent/Fl, Model Fl Res 30, 49 & 58 Recessed Pendent/ F2, Model Fl Res 30,49 & 58 Recessed Pendentl FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Deflector-to-ceiling distance listing shall be 1" to 8" maximum, only for Fl Res 49. Sprinkler frame and deflec- tor shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded *DuPont Registered Trademark 10. or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (790C)]. Sprinklers shall have a nomi- nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish— spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with 1/2" adjustment (Model F2)] [with 34" adjustment (Model Fl)] [of push-on and thread off design with ½" adjustment (Model FP)]. Standard fin- ish shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Model Fl Res 30, 49 & 58 Recessed Pendent/Fi] [Model Fl Res 30, 49 & 58 Recessed Pendent/F2] [Model Fl Res 30,49 & 58 Recessed Pendent/FP] SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer's installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal as- sembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58 CCP, SIN R351 1, R3516 & R3513 (Bulletin 135). Model Fl Res 44, Fl Res 58 Horizontal Sidewall, Fl Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2" adjustment (Model F2) standard finish should be Bright Chrome and white paint- ed. The Fl Res 58 HSW is also available with low lead frame. Fl Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and Fl Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish— specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, Fl Res 58, Fl Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish— specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). Model Fl Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3,4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 76, SIN R7618 (Bulletin 135). *DuPont Registered Trademark Model Fl Res 76 Recessed Pendent/Fl, Model Fl Res 76 Recessed Pendent/F2, Model Fl Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3%" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (68°C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjust- ment (Model F2)] [with 3%" adjustment (Model El)] [of push-on and thread off design with 1/2" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 76 Recessed Pendent/ Fl] [Model Fl Res 76 Recessed Pendent/F2] [Model Fl Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model Fl Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3%" NFl thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 76 COP, SIN R7618 (Bulletin 135). Finishes (1) Standard Finishes Sprinkler F1, FP F2, Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White and Black White Painted Polyester(') Coated I Special Application Finishes Sprinkler Fl, F2, FP Escutcheons Electroless Nickel PTFE(Tef Ion®)'2) Electroless Nickel PTFE (Teflon®) Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Chrome Dull Chrome Dull ( Other finishes and colors are available on special order. Consult factory for details. (2) cULus listed Corrosion Resistant Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Cover Plate Finish *DuPont Registered Trademark The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. AN Recycled Relml a ble, (800) 431-1588 Sales Offices w Paper (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A.06/15 P/N 9999970235