187 CHERRY AVE; ; FPR2019-0027; Permit
(City of Carlsbad Print Date: 07/27/2022 Permit No: FPR2019-0027 Job Address: 187 CHERRY AVE. CARLSBAD, CA 92008-8213 Status: Closed - Finaled Permit Type: FIRE-Construction Residential Work Class: Multifamily Fire Alarm Parcel #: 2042320100 Track #: Applied: 02/25/2019 Valuation: $0.00 Lot #: Issued: 03/06/2019 Occupancy Group: Project #: Finaled Close Out: 10/16/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check #: Project Title: Description: CHERRYFIELD BEACH HOMES- NEW FIRE ALARM SYSTEM Applicant: FPContractor: SYMONS FIRE PROTECTION INC SYMONS FIRE PROTECTION INC MICHAEL GULINO 9475 CHESAPEAKE DR 12155 PAINE PL SAN DIEGO, CA 92123-1336-SAN DIEGO POWAY, CA 92064-7154 (619) 588-6364 (619) 588-6364 FEE AMOUNT FIRE New Alarm System $1,265.00 FIRE Plan Review Per Hour - Overtime $304.00 Total Fees: $1,569.00 Total Payments To Date: $1,569.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov hr "Affi. 7i7jY&IK 0 FZ ES PI C:> NI S \f E C FZ ES CD U r ( E F Li U C LI L - Fire Alarm System Complete Material Submittal Prepared for: Cherry-Field Beach Homes 187, 19 1 & 195 Cherry Street Carlsbad, CA 92008 February 2 1st, 20 19 12155 Paine Place • Poway, CA 92064 4(619) 588-6364 4 Fax (619) 588-6805 4 CA Lic. #682025 FZ ES I = NJ S \f E 0 rR ES C) LI R <-- E F U L 0 FZ E LI L EE TABLE OF CONTENTS - FIRE SPRINKLER MONITORING SYSTEM SUBMITTAL TABLE OF CONTENTS FIRE SPRINKLER MONITORING SILENT KNIGHT - FIRE ALARM SYSTEM CONVENTIONAL PANEL - 5208 TELGUARD - CELLULAR ALARM COMMUNICATOR - TG7-FS SPACE AGE - FIRE ALARM DOCUMENT CABINET - ACE- il INTERSTATE —12 V / 7Ah - SEALED LEAD ACID BATTERIES - SLA-0 124 SILENT KNIGHT— FIRE ALARM SYSTEM MANUAL PULL STATION - PS-SA SYSTEM SENSOR - FIRE ALARM SYSTEM PHOTOELECTRIC SMOKE DETECTOR - 2W-B SYSTEM SENSOR - FIRE ALARM SYSTEM LOW-FREQUENCY HORN - HW-LF S SYSTEMS SENSOR - FIRE ALARM SYSTEM WEATHERPROOF HORN/STROBE - P2RK S 12155 Paine Place 4 Poway, CA 92064 • (619) 588-6364 4 Fax (619) 588-6805 • CA Lic. #682025 S D SILENT KNIGHT a by Honeywell Model 5208 Fire Alarm Control Panel with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features 10 zones, 8 Class B (Style B) and 2 Class A (Style D) or Class B (Style B) zones, expandable to 30 zones Supervised zone expanders and I/O modules can be mounted remotely from the main control panel Event History Buffer (150 events) with date/time stamp All zones are compatible with 2- or 4-wire detectors 8 selectable/programmable output patterns for notification appliance circuits Built-in Digital Alarm Communicator Transmitter (DACT) 4 Notification Appliance Circuits 4 programmable general purpose relays Programmable smoke verification, pre-alarm delay, cross zoning and enhanced verification mode features that can help minimize false alarms Programmable from the built-in control panel touchpad, remote annunciator, or Windows® SKSS downloading software Direct connect port for on-site up/downloading with Windows® SKSS downloading software Built-in walk test feature Single or dual interlock water releasing capability Plex door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Programmable AC trouble relay Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor®, and Wheelock® Programmable date settings for Daylight Saving Time Clock source setting options for 50 Hz, 60 Hz, or internal (uses the panel's internal clock) Specifications Operating Voltage: 24 VDC Primary AC: 120 Vrms @60Hz, 2A Total DC Load: 6 Amp Current Draw: Standby: 140 mA Alarm: 460 mA Flush Mounting Dimensions: Height: 24.75" (62.9 cm) Width: 14.5" (36.8 cm) Depth: 3-7/16" (8.73 cm) with 5/8" protruding Overall Dimensions: Height: 26-3/8" (67 cm) Width: 17-3/16" (43.66 cm) Total Depth: 4" (10.16 cm) Operating Temp: 32° to 120° F (0°t049° C) Humidity: 10 - 93% noncondensing Optional Accessories SK-5235 LCD Remote Annunciator SK-5217 10 Zone Expander (2 max. per system) SK-5280 Status Display Module (8 max. per system) 5220 Direct Connect Module 5824 Serial/Parallel Printer Interlace Module SKSS Downloading Software 4- - 4' •t•. •• UI SK-5208 Plex-2 Door Option SK-SCK Seismic Compliance Kit Listings and Approvals UL Listed CSFM Listed MEA approval 429-92-E Vol. XIII OSHPD (CA) OSP-0065-10 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 Direct Connect For On-Site Programming Programmable Form C Relays • _______ Notification Appliance Circuits L um J E5235 Remote nfl '\ 1 ' tt • Annunciators ____ SBUS Devices 5280, 5217,&5824 To AC This document is not intended to be used for installation purposes. We try to MADE IN AMERICA D SILENT keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350318 Rev E subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc. 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, by Honeywell Fax: (203) 484-7118. For Technical support, Please call 800-446-6444. www.silentknight.com 2 Class A (Style D) or Class B (Style B Initiation Circuits 8 Class B (Style B) Initiation Circuits CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ S LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING No. 7165-0559:0137 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennetthoneywell.com DESIGN: Model SK-5208 fire alarm control unit. Power-limited, automatic, manual, remote station, central station, waterfiow, Releasing Device Service, and sprinkler supervisory services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5K5208 Control Unit SK-5220 Direct Connect Module SK-5280 Status Display Module SK-5217 Zone Expander SK-5235 Remote Annunciator SK-2190 Enclosure SK-7181 Zone Converter RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: 1. For the Alarm Verification Feature (delay of fire alarm), the maximum Retard/Reset/Restart shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0137 Page 1 of I CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Model SK-5208 fire alarm control unit. Power-limited, automatic, manual, remote station, central station, waterfiow, Releasing Device Service, and sprinkler supervisory services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5K5208 Control Unit SK-5220 Direct Connect Module SK-5280 Status Display Module SK-5217 Zone Expander SK-5235 Remote Annunciator SK-2190 Enclosure SK-7181 Zone Converter RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: 1. For the Alarm Verification Feature (delay of fire alarm), the maximum Retard/Reset/Restart shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division HOME HOME& ELECTRONICS GARAGE 10/5/2017 Interstate Batteries Detail Sealed Lead Acid Page - 12V 7AH SLA FR 187 FASTON Customer Service 866-842-5368 Recycling WORK & LIGHTING & HEALTH & BATTERIES BY VEHICLE ACCESSORIES MY ACCO JO OFFICE SECURITY MEDICAL TYPE BATTERIES Home >> Sealed Lead Acid! SLA>> 11.0- 13.0 Volts >> 7.0000>> The Genesis SLA0124 battery is constructed Rol for maximum power and capacity. Original equipment quality and performance assured. Common applications include emergency light, security alarms, medical equipment and more. This battery is non- spillable and maintenance free. See the NP112R , Also Fits tab for a list of applications. 00 INTERSTATE BATTERIES Customer Service Live Chat)) M-F 8am-5pm CST Email Customer Service>> Call Toll Free: 866-842-6368 M-F 8am-5pm CST Need a custom battery? >> Your Price: $36.99 List Price: $46.99 THE INTERSTATE BATTERIES Guarantee We want you to be completely satisfied with every battery you purchase from Interstate Batteries.com. If you are not completely satisfied with an item that you purchased, you may return most items within 45 days of delivery for a full refund of the purchase price, minus the shipping charges. For exceptions, please refer to Warranty Exclusions and Return Exclusions. Specifications FReviews1 Also 1 r Best Uses 1 Fwarra1 Iatures!Benefits I Product ID: SLA0124 Milliamp Hours: 0 Voltage: 12 Termination: .187 FASTON SPADES Chemistry: SEALED LEAD ACID Color: GRAY Weight (Ibs): 5.71 Width (in): 2.5600 Length (in): 5.95 Height (in): 3.94 IELP ABOUT BATTERIES CORPORATE ustomer Service Safety Data Sheets(SDS) About Us ite Map FAQ Career Center nvacy Policy Battery Terms News & Press hipping Policy Recycling Racing onditions of Use Warranty Team Member Class Action Settlement ©2017 Interstate Batteries OUR BUSINESS Locations All Battery Centers Distributorships PowerCare All Battery S 1/2 10/5/2017 Interstate Batteries Detail Sealed Lead Acid Page - 12V 7AH SLA FR 187 FASTON 2/2 SIGNAUNG LISTED Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2%deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available FAD ACE-Il FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SIB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords Solid stainless steel piano hinge and other critical system information. Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information Space Age Electronics, Inc. i rit. , 6EF NO r 4 a N mo tOMOANY 800.486.1723 Toll Free Made lS.A. RESYERED,//e!om . MEMBER 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 No Excuses, Just Solutions! ED0549 LT10559 Rev.D 1/2 Key Ring Hooks Business Card Holder ------------- ISPACE AGE EIELECTRONICS, INC. OSpecifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface — Requires Standard USB- Connector Proparty Information Minimum Required Documentation (SIG-FUN) Certifications and Approvals 16.1 System lnstallal Conbactor 60.5 fl. on ,b*.,05.I.d/pd , 6 60 /05 0 10.4 26 1/pans ___________________________________ ld.p0.d..6.I1vP2/p05,d,5Sh0./p a 5- 16.5 Authority Having Jurisdiction: 4 01 ya.o.,vrvod0.4220.4,or4405 SVpbg.Oip;.k onto PocoippM0.p.I. NFPncp.4.10o00h,o 0padpo. r005nkna,.poaa .,p.050s.,dl..2,a..ons2000.o.v, 766,0 12.0 l000soo.1,00aap0051.0poo,00004.po.p.,Th75n.pdn&0 Equipment Information 12o.on41o64v-n,. DWI IDW2 Pr,000 050002 050/a 20 r,.nsp.sp.ao-100./aass..000d.,o.o./S.vosln 1. R- S Sp*oAg% EI.0v357., Io, 2014.54260,44 SIr/SO SO/ISO 200.435.006 .00,.I3ar..os 1110644 R.v.l Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Space Age Electronics, Inc. S www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (lAM EFAD) No Excuses, Just Solutions! This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TCI-18, TCX/A64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFI, lFX/A and IFX/D enclosures. Models ACE-1 1, ACE-12 and ACE-13, *ACE2424 *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listees fire alarm equipment. Refer to listee's Installation Instruction Manual for details. S 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 1.TA TE LG UAR D TG-7FS LT E-A P/N: TG7LAF0I CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS O COMMERCIAL FIRE PRODUCT FEATURES t- Certified for use on the AT&T LTE network for long, sunset-free installation. Meets UL 864 requirements for sole, primary or backup path communications. I- Minimizes false alarms by providing dual paths for self-tests. I- Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LIE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LIE-A can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LIE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LIE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LIE-A because of the new sixty minute supervision mode. The TG-7FS LIE-A can also he installed as a backup path and upgraded to sole path at a later date. ATA Yj7 TG-7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LIE NETWORKS TE LG UAR D (ii it) Ioer Tnsmit owe S. kowe r C-onsumption, 6® ransforr.kOTh U I's lg. Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable HGDL-0: High gain directional antenna. EXDL-0: External antenna. UL Listings Commercial Fire 864 • control units & accessories for fire alarm systems Commercial Burglary 365 Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units: I m security servcies Residential 985 Household fire warning systems 1023 • Household burglar alarm systems ULC Listings S545 • Canadian household fire warning systems S304 Canadian commercial burglary alarm systems C0123 • Canadian household burglary alarm systems - For the most current product specitcatlons and UL Lstlngs visit viovi.jelguardcom SECURITY flfl SIGNALING ////________ 'I \lAELECTkONiC us A /// NFP Connected. LISTED INTERNATIONAL by AT&T Tolguard, a Division of Telular Corporation 3225 Cumberland Blvd SF • Suite 300 Atlanta, GA 30339 USA 800-229-2326. Option 5 www.Telguard.com Copyright c 2017 Telular Corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7LAA02, *TG7lJ001 *TG7Ifi,A01 TG7LA002, *TG7LAF01 TG7LAF02, and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model *TG7LAF0I TG7LAF02, and TGKITLA2 are for commercial application. Refer to Iistees printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 10-03-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S Photoelectric Smoke Detectors System Sensor j3'' series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement -Wide-angle, dual-color LED indication Loop testing via EZWalkfeature Built-in test switch Agency Listings <> MEA MSFM LISTED APPROVED approved approved S911 3011446 7272-1653:152 290-01-E 2093 3180932 Installation ease. The i 3 line redefines installation ease with its plug-in design.This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i heads plug into the base with a simple Stop-Drop 'N Lock' action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the protocol. The SENS-RDR, a wireless device, displays the sensitivityof i detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. (j) Smoke Detector Specifications L. Smoke detector shall be a System Sensor i3 Series model number , listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws, The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 1 2/24 V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @24 V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @30 V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range ' 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2 5%/ft nominal Input Terminals 14 to 22 AWG . Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling 5,151 LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Orderina Information 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4-wire 20mA@ 12V,23mA@24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter 3825 Ohio Avenue. St. Charles, IL 60174 Phone: 800-SENSOR2. Fax: 630-377-6495 020095ys1em Sensor Product specifications s subject to cirange without notice. Visit syssernsensorcorn for r r r AOS-0318-007.6/09.#2169 current product infotmatson, including the latest version of this data sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models 2W-B, 2W1-B, 4W-13 and 4W1-B photoelectric type smoke detectors. Models 2W-13 and 2W1-B are 2-wire and model 4W-B and 4Wr-B are 4-wire detectors. Models 2WT-B and 4Wr-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 S 06-20-05 e This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ILCiNI NIG HI PS-DA PS-DASP Features: Specification: D SILENT KNIGHT by Honeywell PS-DA and PS-SA Conventional Pull-stations Easy to Install and Operate The PS-DA/PS-SA Pull Stations are non-coded manual pull stations which provide a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The PS-DA/PS-SA pull stations includes both single-action and dual-action models equipped with key lock I reset. It was designed to meet multiple applications with the installer and end-user in mind. Its innovative design, durable construction, and multiple mounting options make the PS- DA and PS-SA simple to install, maintain, and operate. S S Operation The single-action pull-station is activated by a single pull-down of the alarm handle. The dual-action versions require pushing in the handle, then pulling the handle down for activation. The PS- DA/PS-SA manual pull stations are UL listed and meet the ADA requirement of a 5-lbs. maximum pull force to activate. Operating instructions are molded into the handle along with Braille text. Molded terminal numbers can be found adjacent to the wiring termi- nals. Models: PS-SA— Single action with pigtail' connections and a key lock reset. Pigtail wires are provided for con- nection to the Fire Alarm Control Panel's (FACP) initiation circuit. PS-DA - Dual action model with screw terminal connections and a key lock reset. PS-DAH - Same as PS-DA except with hex lock reset. PS-DALOB - Same as PS-DA with "outdoor use" listing. Includes SB- I/O backbox and sealing gasket. PS-DASP - Same as PS-DA except with both English and Spanish operating instructions. UL Listed CSFM Listed Meets ADA requirements Operating instructions are mold- ed into the handle along with Braille text. Made of durable Lexan Available in Spanish Key resettable Easy to Install and operate Single or dual action Surface mount box available Dimensions: Height: Width: Depth: Operating temperature: Electrical: Switch Contact Rating: Accessories: SB-I/O BG-TR 5-1/2" (13.97 cm) 4" (10.16 cm) 1-7/16" (3.65 cm) 32°F to 120°F (0°C to 49°C) 0.25A@3OVAC orVDC Surface Mount Back-box Trim Ring PS-DA and PS-SA Conventional Pull-Stations Engineering Specification Manual Fire Alarm Stations shall be non-code, with a key-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching back-box SB-b; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local require- ments. Manual Stations shall be Underwriters Laboratories listed. *NOTE: The words "FIRE/FUEGO" on the PS-DASP shall appear on the front of the station in white letters, approximately 3/4" high. RJ S PS-SA Front View PS-DA Front View PS-SA Rear View PS-DA Rear View SILENT This document is not intended to be used for installation purposes. We try to KKTIT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are sub- 41 to change without notice. For more information, contact Silent Knight 12 by Honeywell Clintonville Road Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA PIN 350241 Rev. D © 2011 Honeywell International Inc. 5 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0140 Page I of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models PS-SA, PS-DA, PS-DASP and IDP-PULL-DA lire alarm pull boxes. The PS series followed by SA or DA is a single action or dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 [I *Updated 09-08-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division if F LE•j:) )) . E Selectable-Output Low Frequency Sounder and Low Frequency Sounder Strobes for Wall Applications SpectrkertO Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features 520 Hz ± 10% square wave tone Plug-in design with minimal intrusion into the back box Tamper-resistant construction Field-selectable candela settings on wall units: 135, 150, 177, and 185 Rotary switch for low frequency sounder tone Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting The SpectrAlert AdvanCe series offers the most versatile and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry. With white and red plastic housings, dual listed for wall and ceiling mounting, SpectrAlert Advance can meet virtually any application requirement. The wall-mount low frequency sounder, and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that require a low frequency notification appliance that operates within frequency range of 520 Hz ± 10% and is of a square wave tone. Like the entire SpectrAlert Advance product line they include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, Agency Listings automatic selection of 12- or 24-volt operation, and a rotary switch for 520 Hz low frequency sounder tones. SIBNAIJNG & <~> MEA LISTED APPROVED approved S401(Sounder) 3047563 Mt A452-05-I S5512 (Strobes) 7135-1653:0223 7125-1653:0224 SpectrAlert Advance Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync'Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, and 185. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone and have a permanent marking on the housing that reads low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts (includes fire alarm panels with built in sync). When used with the Sync.Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three pattern, non-temporal (continuous) pattern and coded supply within the frequency range of 520Hz ± 10% square wave tone. The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Frequency Range 520 Hz ± 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/F\NR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) -input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm Lx 119mmWx64mm 0) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142 mm Lx 119 mm x33 mm 0) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions (SBBR, SBBW) (162 mm Lx 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR, SBBW) (145 mm Lx 120 mm W x 76 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. UL Current Draw Data .P4tVolts - .1.! Temporal High 191 262 138 166 Continuous High 292 384 138 208 Coded High 292 388 153 205 Input _DC 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal 3 277 292 325 344 Temporal 3 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Sounder Tones and Sound Output Data 8-17.5 16-33 Volts Volts Switch Position Sound Pattern 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal 3 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3f Coded 80 80 80 80 80 80 90 90 t Sounder ratings provided are for continuous voltage as provided by the NAC 0 4 4.7 in. 6.4 in. I SpectrAlert Advance Dimensions Wall-mount low frequency sounder strobes Wall-mount low frequency sounder S SpectrAlert Advance Ordering Information Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe, High cd, Red P2WH-LF 2-Wire Low Frequency Sounder Strobe, High cd, White Low Frequency Sounders HR-LF Low Frequency Sounder, Red HW-LF Low Frequency Sounder, White Accessories SBBR Surface Mount Back Box, Wall, Red SBBW Surface Mount Back Box, Wall, White TR-HS Trim Ring, Wall, Red Notes: "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. T 1 5yyjq 3825 Ohio Avenue • St. Charles, IL 60174 02015 System sensor. ..$ 1SE..5O! Phone: 800-SENSOR2 • Fax: 630-377-6495 Product Specifications subject to change without notice. Volt syslenlsensor.cc.rs for current product information, including the latest version of this data sheet. www.systemsensor.com AVDS16404 • 1/15 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0223 Page 1 of I CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models HR-LF and HW-LF horns. Intended for indoor use and suitable for wall or ceiling mount. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VdcNFWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal. *These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to manufacturer's Installation Manual for details. S S *Rev 07-22-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTE Outdoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from —40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings SIGNALING S @ FM 0 7300-1653:187 (outdoor strobes) LISTED S401 (chimes, horn strobes, torso) APPROVED approved 7125-1653 188 thorn strobes. chime strobes) S3593 (outdoor and alert strobes) 3023572 M8A452-05-E 7135-1653:189 (horns. chimes) SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 3,4-inch top and bottom conduit entries and 3,4-inch knock-outs at the back. A screw-in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 120124 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature —40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/F\NR1 Operating Voltage Range2 8 to 17,5 V (12 V nominal) or 16 to 33 V (24 V nominal) -input Terminal Wire Gauge 12to18AWG Wall-Mount Dimensions (including lens) 5.6' L x 4.7W x 2.5' D (142 mm L x 119 mm W x 64 mm 0) Horn Dimensions 5.6'T x 4.7"W x 1.3'D (142 mm Lx 119 mm W x 33 mm Dl Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7'L x 5.1"W x 2.0"D (145 mm Lx 130 mm W x 51 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. F, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVOSO1 201 S UL Current Draw Data 71 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela 15/75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 Sound Pattern dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 S 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 Range 177 185 NA NA NA NA NA NA 246 220 281 251 286 258 Coded Low 40 46 52 - 50 DC Input 8-17.5 Volts 15 15/75 16-33 Volts 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts _DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures listed candela ratings must be reduced in accordance with this table. Horn Tones and Sound Output Data 8-17.5 16-33 Switch Sound Volts Volts 24-Volt Nominal Reverberant Anechoic Position Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. Avos01201 _. .i Listed Candela Candela rating at —40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 AN IT 41FF Wall-Mount Horn Strobes rproof Back Box SpectrAlert Advance Diagrams Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information S Wall Horn Strobes P2RK*l 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*I Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add '-P' to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings, "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. @20 2 system Sensor. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject tolchange aSE7tL5Ol Phone 800-SENSOR2 • Fax 630-377-6495 or curreat product ntormationjrrcluding the latest version of this data sheet. notice. visit systemsensorcom CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL It FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM lL LISTING SERVICE LISTING No. 7135-1653:0189 Page 1 of I CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models HR, HW Horns and CHR, CHW chimes. Intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use. "K" suffice models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA *4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), *SA..tBW (Wall), SA-WBBC (Ceiling) and *SA..BCW (Ceiling). Models CHR and CHW are intended for private mode use only. Suitable for wall or ceiling mount. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8 - 17.5 or 16-33 VdcNFWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control • units. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. *Rev 12-01-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division