HomeMy WebLinkAbout2742 STATE ST; ; FPC2020-0025; Permit2r;I1 WP1iTIi 1::2i1 JI (city of Carlsbad FnlelaelFmlilt Print Date: 11/06/2020 Permit No: FPC2020-0025 Job Address: 2742 STATE ST, CARLSBAD, CA 92008-1628 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel 4: 2031811900 Track 4: Applied: 02/07/2020 Valuation: $0.00 Lot #: Issued: 02/20/2020 Occupancy Group: Project 4: Finaled Close Out: 10/16/2020 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 4: Inspector: Plan Check U: Final Inspection: Project Title: Description: STATE STREET COMMONS -SPRINKLER MONITORING & ELEVATOR RECALL SYSTEM FPContractor: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO, CA 92029-1924 (760) 747-3050 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov &EIUISES FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS STATE STREET COMMONS 2742-2752 STATE ST. CARLSBAD, CA 92008 FIRE SPRINKLER MONITORING & ELEVATOR RECALL PRODUCT DATA SHEETS by Honeywell NFW-IOOX Intelligent Addressable FACP with Communicator General The FireWarden-100X (NFW-IOOX) is the latest intelligent address- able Fire Alarm Control Panel (FACP) within the FireWarden Series. The NFW-100X comes with a pre-installed communicator and sup- ports up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the NFW-100X programs just like FireWarden-100 products, yet fits into applications previ- ously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-N. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTM). Features Listed to UL Standard 864, 10th edition Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator over AlarmNet Optional CELL-MOD or CELL-CAB-N GSM Central Station Com- municator over AlarmNet® Automated activation of the NFC-501100 Emergency Command Center NFC-FFT Firefighter Telephone option Compatible with SWIFT® wireless devices Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address Four built-in, independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices Notification Appliance Circuit End of Line resistor matching Four programmable function keys for ease of maintenance Two programmable relays and one fixed trouble relay Built-in Programmer Integral 80-character LCD display with backlighting Real-time clock/calendar with automatic daylight savings control History file with 1,000 event capacity Addressable sounder base compatibility Control module delay timer Automatic detector sensitivity testing (NFPA 72 compliant) Automatic device type-code verification Point trouble identification Waterfiow selection per module point Alarm verification selection per detector point Maintenance alert warns when smoke detector dust accumula- tion is excessive One-person audible or silent walk test with walk-test log and printout System alarm verification selection per detector pcint PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP Supports FlashScan® and CLIP protocols SLC operates up to 10,000 ft. (3,000 m) in Flas:l3can mode with twisted, unshielded wire Single addressable SLC loop which meets NFPA Class B and Class A requirements 198 addressable device capacity (99 addressa-D e detectors and 99 modules) Compatible with NOTIFIER FireWarden and ONYX Series addressable devices (refer to the FireWarden SLC Wiring Man- ual) NOTIFICATION APPLIANCE CIRCUITS (NACSJ Four independently programmable output circuits. Circuits can be configured for the following outputs: - Style Y (Class B) - Style Z (Class A) Silence Inhibit and Autosilence timer options Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability Selectable strobe synchronization per NAC 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shareci between all NAC circuits and the ANN-BUS is 2.7 A DN-60959:A 3'6j2018—Page 1 of 4 PROGRAMMING AND SOFTWARE Autoprogramming (learn mode) reduces installation time Custom English labels (per point) may be manually entered or selected from an internal library file Two programmable Form-C relay outputs 99 software zones Continuous fire protection during online programming Program Check automatically catches common errors not linked to any zone or input point OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows®-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.notifier.com. User interface LED INDICATORS Fire Alarm (red) • CO Alarm (red) AC Power (green) Supervisory (yellow) Trouble (yellow) • Ground fault (yellow) Battery fault (yellow) Disabled (yellow) Maintenance (yellow) Communication (yellow) Alarm Silenced (yellow) F1-F4 Programmable Function Keys (yellow) KEYPAD 16 key alpha-numeric pad • Acknowledge Alarm Silence • Drill (Manual Evacuate) Four (4) programmable function keys • Reset (lamp test) PRODUCT LINE INFORMATION NFW-IOOX: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display chassis with trans- former, backbox with door, plastic bag containing screws, cables, key, etc. FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.notifier.com. CELL-CAB-NICELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the NFW-100X (red). OP-ES-B: Optional dress panel for NFW-100X (black). TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For red, order TR-CE.) BB-XP: Optional cabinet for one or two modules. Optional cabinet for up to six modules mounted on CHS-6 chassis. Battery backbox, holds up to two 25 AH batteries and CHG- 75. NFS-LBB: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-25 cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-I20: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG- 120 or CHG-75 required for batteries larger than I8AH. BAT Series: Batteries, see data sheet DN-6933. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTM Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. Increases alarm power output to 6 amps. COMPATIBLE ANNUNCIATORS N-ANN-80: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. (Basic model is black; order -W for white; see DN-7114.) N-ANN-I OOR: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. (Basic model is black; order R for red.) N-ANN-1/0: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DN-7105.) N-ANN-LEO: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DN-60242.) N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242.) N-ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DN-7107.) N-ANN-SIPG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) ADDRESSABLE DEVICES FSP-951: Addressable low-profile photoelectric smoke detector. FlashScan only. FSP-951-IV: Addressable low-profile photoelectric smoke detector. Ivory. FlashScan and CLIP mode. NP-200: Addressable low-profile photoelectric smoke detector. B300-6 base included, FlashScan only. NP-200-IV: Addressable low-profile photoelectric smoke detector. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951T: Addressable low-profile photoelectric smoke detector with thermal sensor. FlashScan only. FSP-951T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. FlashScan and CLIP mode. NP-200T: Addressable low-profile photoelectric smoke detector with thermal sensor. B300-6 base included. FlashScan only. NP-200T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951 R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. FSP-951R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. FlashScan and CLIP mode. NP-200R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. NP-200R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory, FlashS- can and CLIP mode. FST-951: Low-profile 135°F fixed thermal sensor. FlashScan only. FST-9514V: Low-profile 135°F fixed thermal sensor. Ivory. FlashS- can and CLIP mode. NH-200: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. FST-951R: Low-profile, intelligent, rate-of-rise thermal sensor. FlashScan only. FST-951 R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. FlashScan and CLIP mode. Page 2 of 4— DN-60959:A 3/6/2018 NH-200R: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200R-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6- IV base included, FlashScan and CLIP mode. FST-951H: Low-profile intelligent 190°F188°C fixed thermal sensor. FlashScan only. FST-951H-IV: Low-profile intelligent 190°F188°C fixed thermal sen- sor. Ivory. FlashScan and CLIP mode. NH-200H: Low-profile intelligent 190°F/88°C fixed thermal sensor. B300-6 base included, FlashScan only. NH-200H-IV: Low-profile intelligent 190°F188°C fixed thermal sen- sor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. Legacy Devices FSI-851: Addressable low-profile ionization smoke detector. NI-100: Addressable low-profile ionization smoke detector. FSP-851: Addressable low-profile photoelectric smoke detector. NP-IOU: Addressable low-profile photoelectric smoke detector. FSP-851T: Addressable low-profile photoelectric smoke detector with thermal sensor. NP-1 OUT: Addressable low-profile photoelectric smoke detector with thermal sensor. FSP-851R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. NP-I0OR: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FST-851: Fast-response, low-profile heat detector. NH-IOU: Fast-response, low-profile heat detector. FST-851 R: Fast-response, low-profile heat detector with rate-of-rise option. NH-100R: Fast-response, low-profile heat detector with rate-of-rise option. FST-851 H: Fast-response, low-profile heat detector that activates at 190°F188°C. NH-I OOH: Fast-response, low-profile heat detector that activates at 190°F188°C. FAPT-851: Addressable low-profile multi-sensor detector. NP-Al 00: Addressable low-profile multi-sensor detector. B200SR: Addressable sounder base. DNR: InnovairFIex low-flow non-relay duct-detector housing. (Order FSP-851R, FSP-951R, or NP-100R separately.) DNRW: InnovairFIex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order FSP-851R, FSP-951R, or NP- 100R separately.) Addressable Modules FMM-I: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0° (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NMM-I00: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. FDM-I: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs. NDM-100: Dual Monitor Module. Same as NMM-100 except it pro- vides two Style B (Class B) only IDCs. FMM-101: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NMM-1 OOP: Miniature version of NMM-1 00. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. FZM-I: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. NZM-I00: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. FCM-I: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0° (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. NC-IOU: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0' (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. FRM-I: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM13500. NC-I OUR: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMBSOO. NBG-12LX: Addressable manual pull station with interface module mounted inside. NOT-BGI2LX: Addressable manual pull station with interface mod- ule mounted inside. ISO-X: Fault Isolator Module. N100-ISO: Fault Isolator Module. ISO-6: Six-fault isolator module. Mount one or two modules in a BB- XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SMB500: Used to mount all modules except the FMM-101/NMM- 1oop. NMM-I00-I0: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NZM-I00-6: Six-zone interface module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SWIFT Wireless Devices FWSG: Wireless Gateway FWD-200P: intelligent, wireless photo detector. FWH-200R0R135: LiteSpeed intelligent wireless rate of rise (135°) heat detector. FWD-200ACCLIMATE: Wireless Acclimate Detector FWH-200FIXI 35: intelligent wireless fixed-temperature (135°) heat detector. FW-MM: Intelligent wireless monitor module. FW-RM: Intelligent wireless relay module. NBG-I 2LW: Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden- IOOX, see the following data sheets (document numbers): NP-200 Series (DN-60979), NH-200 Series (DN-60980), FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), NIOO-ISO (DN-6994), NP-100 series (DN-6995), NH-100/NH-IOOR (DN- 6997), DNR/lnnovairFlex (DN-60424, DN-60429), NP-A100 (DN-6998), NMM-IOOINMM-IOOP/NDM- 100/NZM-100 (DN-6999), NC-100 (DN- 7000), NC-IOOR (DN-60383), NMM-100-10 (DN-6990), MM-1/FDM-1/ FZM-1/FMM-101 (DN-6720), FCM-1/FRM-1 (DN-6724), NOT-BGI2LX (DN-7001), NBG-I2LX (DN-6 726), and Fire Wa rden SLC Manual (52304). DN-60959:A • 3/6/2018 - Page 3 of 4 SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits ................................................ 1 Addressable device capacity..................................................198 Programmable software zones.................................................99 Annunciators.............................................................................16 Electrical Specifications AC Power: 120/240 VAC, 50/60 Hz, 3.25 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, super- vised. Battery: Two 12 V 18 A lead-acid batteries. Battery Charger Capacity: 7-18 AH (FireWarden-100X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for four NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End-of-Line Resistor: 4.7k ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 kfl - 22 k1 ELR range. Refer to the NOTIFIER Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non-power-limited, non-supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE/B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 —120°F and at relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F. Addressable Device Accessories End-of-Line Resistor Assembly (R-47K and R-3.91K): The 47k ohm assembly supervises the NMM-100-10, NDM-100, NMM- lOOP, and NC-IOU module circuits. The 3.9k ohm assembly super- vises the NZM-1 00-6 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. NFPA Standards The FireWarden-IOOX complies with the following NFPA 72 Fire Alarm Systems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). —AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) — PROPRIETARY (Automatic, Manual and Waterflow). — CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). — OT, PSDN (Other Technologies, Packet-switched Data Net- work) — IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). — CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic FireWarden- 100X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 CSFM: 7165-0028:0505 iso ooi C.. b Sl• p.1 L5l? I MWlIF11IIU OUAtITY SYSTEMS This document is not intended to be used for installation purposes. We fry to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. pjarmNet®, NOTIFIER®, FireWarden®, SWIFT®, and System Sensor®) NOTI Fl ER are registered trademarks of Honeywell International Inc. Microsoft® and 12 Clintonville Road Windows® are registered trademarks of the Microsoft Corporation. Northford, CT 06472 52018 by Honeywell International Inc. All rights reserved. Unauthorized 203.484.7161 use of this document is strictly prohibited www.notifier.com Country of Origin: USA P1OTFDER by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:0505 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models FireWarden-50X (NFW-50X) and FireWarden-100X *(NFW 100X) Fire Alarm Control Units. Automatic, manual, waterfowl, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. The FireWarden-50X (NFW-50X) is a compact version of the FireWarden-100X *(NFW100X) The FireWarden-50X (NFW-50X) has 50 addressable device capability and 2 Notification Appliance Circuits with a 3.0 amps total 24VDC output in Alarm. The FireWarden-100X *(NFw..iooX) has 198 addressable device capability and 4 Notification Appliance Circuits with 3.oamps total 24VDC output in Alarm expandable to 6.0amps with Model PWRMOD24. The Model IPOTS-COM provides Phone and IP communication. Models FireWarden-50X (NFW-50X) and FireWarden-100X *(NFw..iooX) system components are as follows: IPOTS-COM POTS and IP Communicator 4XTMF Transmitter Module N-ANN-80 Remote Annunciator Module ANN-100 Remote Annunciator Module N-ANN-I/O LED Driver Module N-AN N-S/PG Serial/Parallel Interface Module N-ANN-RLY Form-C Relay Module N-ANN-LED Annunciator Module N-ANN-RLED Annunciator Module CELL-MOD GSM Communicator DP-ES-R Dress Panel Model FireWarden-100X *(NFW..loox) system components are as follows: PWRMOD24 NAC Power Expander Module Refer to the listee's data sheet for additional detailed product description and operational considerations. RATING: 120/240Vac 50/60Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. *Rev 09-03-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, M.E., F.P.E., Program Coordinator Fire Engineering Division Listing No. 7165-0028:0505 Page 2 of 2 MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units, emergency alarm system control units and process management equipment for use with separately listed compatible initiating and indicating devices. Refer to Manufacturers Installation Instruction Manual for details. NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. XLF: 7165-0075:0500 *Rev 09-03-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, M.E., F.P.E., Program Coordinator Fire Engineering Division I .. CELLULAR ALARM V TGm7FS COMMUNICATOR FOR .G/4G NETWORKS TELGUARD 8 COMMERCIAL FIRE PRODUCT FEATURES Meets UL 864 requirements for sole, primary or backup path communications. I" Provides RMR protection by leveraging technology that operates on 3G/4G networks. I' Supports listen-in, two-way voice verification over cellular. Minimizes false alarms by p\? dl 5R'±hs for self-tes. Falls back to 2G (GSM) if a 3G/4G network isn't available. The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2010 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within five minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7F5 because of the new five minute supervision mode. The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. fl 3 f JTWKS T E L Gi) A R D 4j N j - N N IL. N *Me. - N. MOW N 4 I Telguard technologyltosfuH data reporting for unhmkjtN öihtto-point signal details and maximum tansmitting power for Uerior in -building penetration Thluardproducts are easy toNinsta1teconomicaL and UL Listed N N Agoe N N ACD12ACD35N.ACD5OACD100 NN W. 12/35/50/100 feef6f lilss high pef6rmance cable N HGDOHigh ..... EXD-O Externalantennarnw — 1PPL N PPPNN , tt NNNN. NN N N N N :A N ON N ...•. .....•. N .. N N N N UL ListingsIi . Commercial Fire - Commercial Burglary Residential 864N Control units & 365N Poli Station 985 Household fire N. I NNN0 N. cc ori for fire connected burglaro, o. warning systems al'arrn systers r 'o aIarm units and . systems NNZ Pi5N p- -. 1610 CentrLstationburgiar . •. Line security SOtVCiOSN ON N P 0 pp'fr'theM1OSttUrreflt product spec&catlons andy tlstP siwwwTelguord corn N,. ctNN........................N;NNPPyoPN...... ELECTRONIC SECURIV IATION ,. VNP ppp N. P-N 0N.'o, LJ ONPNPPN.P N. P P ISTED' NFPA4A /fli - - III1t4thATIONAL . - N C Teiguard, a Division of Teluier Corporation 2727 Paces Ferry Road SF GA 30339 • USA 900-229-2326, Option S www.TelgLiard.com Copyright ri2q2 Telular Corporation All Rights Reserved '0, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM kn4o,iq~;, LISTING SERVICE LISTING No. 7300-1516:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: AES CORPORATION285 NEWBURY ST, PEABODY, MA 01960 Contact: Jim Burditt (978) 839-7109 Fax (978) 535-7313 Email: jburditt@aes-intellinet.com DESIGN: Model 7794 (FirePro) Digital Dialer Interface. Model is intended for use with 7744F and 7788F subscriber unit and as a supplemental use. It takes industry standard communication formats provided by the FACP units' DACT and transfers the data to the subscriber unit where it is transmitted to the AES MultiNet Receiver System. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 12V dc INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as miscellaneous devices for use with separately listed manufacturer's Model 7744F and 7788F subscriber unit. Refer to listees Installation Instruction Manual for details. 07-07-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division cn-7114:c • Al -65 N.ANN-80 ' OT Fl E R 80-Character LCD Serial Annunciator by Honeywell ----r----- --- General The N-ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The N-ANN-80 and the FACP communicate over a two- wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. N-ANN-80 is black; for white order N-ANN-80-W. The N-ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight N-ANN-805 may be connected to the ANN-BUS of each FACP. Minimal programming is required, which saves time during system commissioning. The N-ANN-80 is compatible with NOTIFIER FACPs with an ANN-BUS, such as the NFW-50. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. N-ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4" square electrical box. Semi-flush mount to single, double, or 4" square electrical box. Use ANN-5B80K1T for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight N-ANN-805 can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC tc 28 VDC. Current consumption @ 24 VDC icminal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 49°C). Relative humidity: 93% ± 2% RH (roncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep. For use indoors in a dry location. All connections are power-limited .aic supervised. Agency Listings and Approvals The listings and approvals below apply to the N-ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 FM approved CSFM: 7120-0028:240 MEA: 442-06-E Vol. 2 The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxil ary power supply when the maximum number of ANF-BUS devices exceeds the ANN-BUS power requirements. See tie FACP manual for more information. dr-71 14:c • 5/22/09 - Page 1 of 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The N-ANN-80 connects to the FACP ANN-BUS communica- tions circuit. To determine the type of wire and the maximum wir- ing distance that can be used with FACP ANN-BUS accessory modules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*). Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. All connections are power-limited and supervised. A maximum of eight N-ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case 22 Gauge Current Draw (amps) 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. 6,000 ft. *6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. ANN-BUS and power wiring are supervised and power-limited. = TBI ANN-BUS Device ORDERING OPTIONS: N-ANN-80: Black 80 character LCD Annunciator. N-ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80K1T-B: Black surface mount backbox with angled wedge. ANN-SB80K1T-W: White surface mount backbox with angled wedge. [1IQl1lLI lasr'i'i'I Z 'i — FACP Wiring to ANN-BUS Device 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. -. - ISO gooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. b We cannot cover all specific applications or anticipate all requirements. CINEEN1 Ill MANUFACTUMNI All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-7114:c • 5/22/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:0240 Page 1 of 1 CATEGORY: 7120--ANNUNCIATORS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models N-ANN-80 and *N..ANN80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciator for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. XLF: 7120-0075:0211 *Rev 12-11-14gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-60979:A NP-200 Series Addressable Photoelectric Detectors General The NOTIFIER NP-200 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. Exclusively for use with NOTIFIER's FireWarden Series Addressable Fire Alarm Control Panels, the NP-200 Series point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indi- cation. Dual electronic thermistors add 135°F (57°C) fixed tempera- ture thermal sensing on the NP-200T. The NP-200R is a remote test capable detector for use with DNR Series duct detector housings. Features SLC LOOP Two-wire loop connection. Unit uses base for wiring. ADDRESSING Addressable by device. Rotary, decimal addressing: Please refer to the FireWarden panel manuals for device capacity. ARCHITECTURE New modern profile for improved aesthetics. Unique single-source design to respond quickly and dependably to a broad range of fires. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. OPERATION Designed to meet UL 268 7th Edition. Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level. Visible LED "blinks" when the unit is addressed (communicating with the fire panel) and latches on in alarm. • Low standby current. MECHANICALS Sealed against back pressure. Mounts to: single-gang box, 3.5 (8.89 cm) or 4.0 (10.16 cm) octagonal box, or 4.0 (10.16 cm) square electrical box (with or without a mud ring - not included). OPTIONS Remote LED output connection, RA100Z. Installation NP-200 series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. NOTIFIER by Honeywell NP-200 in B300-6 Base Mount base (all base types) on an electrical backbox which is at least 1.5 (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class B) wiring. NP-200R mounts in a DNR/DNRW duct detector housing. Operation Each NP-200 Series detector uses one possible addresses on the FireWarden Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an FireWarden Series addressable fire alarm control panel. The results of the sensitivity test can be printed off the Fire- Warden Series for record keeping. Specification Voltage range: 15 —32 VDC (peak). Standby current: 200 pA @ 24 VDC. Max current: 4.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft./min. (20 m/sec.) maximum. Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration Size: 2.0 (5.3 cm) high; base determines diameter. - B300-6: 6.1" (15.6 cm) diameter. - B501: 4(10.2cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4 oz. (95 g). Operating temperature range: NP-200: 0°C to 50°C (32°F to 122°F); NP-200T: 0°C to 38°C (32°F to 100°F). NP-200R: installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). DN-60979:A • 3/29/18 - Page 1 of 3 Relative humidity: 10%-93%, non-condensing. Listings Listings and approvals below apply to the N P200 Series detectors. In some cases, certain detectors may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listed: S911 CSFM: 7272-0028:0503 FM Approved Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. NOTE: "IV" suffix indicates FlashScan@ and CLIP device. NP-200: White, Addressable photoelectric detector; B300-6 base included. FlashScan only. NP-200-IV: Ivory, Addressable photoelectric detector; B300-6 base included. NP-200T: White, Same as NP-200 but with thermal element; B300-6 base included. FlashScan only. NP-200T-IV: Ivory, Same as NP-200 but with thermal element; B300-6 base included. NP-200R: White, Remote test capable addressable photoelectric detector for use with DNR(A)/DNRW. FlashScan only. NP-200R-IV: Ivory, Remote test capable addressable photoelectric detector; for use with DNR(A)/DNRW. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. 13300-6: White, 6" base, standard flanged low-profile mounting base. - (CSFM: 7300-1653:0109 Pending) B300-6-IS: White, 6" base isolator. (CSFM: 7300-1653:0109 Pend- ing) B300-6-IV: lvory,6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) 13300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-BL: Black, 4" standard European flangeless mounting base. ULJULC listed. (CSFM: 7300-1653:0109 Pending) B501-IV: Ivory color, 4" standard European flangeless mounting base. ULIULC listed. (CSFM: 7300-1653:0109 Pending) B501 BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. (CSFM: 7300-1653:0216 Pending) B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216 Pending) B224RBA-Wl-I: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224B1-WH: White, isolator detector base. (CSFM: 7300- 1653:0216 Pending) B224B1-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216 Pending) B224B1A-WH: White, isolator detector base, ULC listing. B224B1A-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B2005-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. . (CSFM: 7300-1653:0213 Pending) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B2005-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. TR300-IV: Ivory, replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. DN-60979:A • 3/29/18 - Page 2 of 3 NOTIFIER® and FIREWARDEN® are a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. I SO 9001 We cannot cover all specific applications or anticipate all requirements. ____________ All specifications are subject to change without notice. U I MCINFERING 8 MANOI8C11IRING QUALITY SYSTEMS For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203)484-7118. www.notifier.com Page 3 of 3— DN-60979:A • 3/29/16 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0503 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact; Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models FSP-951, FSP-951R, FSP-951T, FSP-951T-ISO, NP-200, NP-200R, and NP-200T analog addressable, photoelectric smoke detectors for open area and duct installations. Models FSP-951T, FSP-951T-ISO and NP-200T have complementary heat detectors. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed bases: *Model B71OLP (CSFM No. 7300-0028:0173); System Sensor Models *13224131, *13224RB (CSFM No. 7300-1653:0126); 13200S, B200SR (CSFM No. 7300-1653:0213); B200S-LF, B200SR-LF (CSFM No. 7300-1653:0238); *13501 *B210LP 13300-6, B300-6-IS (CSFM No. 7300-1653:0109). System Sensor duct detector housings Models DNR and DNRW (CSFM No. 3240-1653:0209), Fire-Lite duct detector housing Model D355PL (CSFM No. 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. *Rev 02-14-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division NOTllFER by Honeywell NH-200 Series Addressable Heat Detectors for FireWarden Series The NOTIFIER® NH-200 Series intelligent thermal detectors are designed for both performance and aesthetics, and are direct replacements for the NH-1 00 Series. A new modern, sleek, contem- porary design and advanced thermal technologies make the NH-200 Series ideal for both system operation and building design. The point ID address, set using rotary decimal switches, provide specific detector locations. Compatible with FireWarden® Series fire alarm control panels, the series includes a 135°F157°C fixed-temperature, rate-of-rise, and a 190°F/88°C fixed high-temperature detectors. These thermal detec- tors provide effective, intelligent property protection in a variety of applications. Detectors are available for both FlashScan® and CLIP applications as designated. Features SLC LOOP: Two-wire SLC loop connection Unit uses base for wiring ADDRESSING: Addressable by device Rotary, decimal addressing (Refer to the FireWarden panel manuals for device capacity.) ARCHITECTURE: Designed to meet UL 268 7th Edition Sleek, low-profile, stylish design State-of-the-art thermistor technology for fast response Integral communications and built-in device-type identification Built-in tamper resistant feature Built-in functional test switch activated by external magnet OPERATION: Fixed temperature model (NH-200) factory preset to 135°F (57°C) Rate-of-rise model (NH-200R),15°F (8.3°C) per minute High-temperature model (NH-200H) factory preset to 190°F (88°C) 360°-field viewing angle of the two visual alarm indicators, LEDs blink red in Normal condition and turn on steady red in Alarm • LEDs blink every time the unit is polled MECHANICALS: Sealed against back pressure SEMS screws for wiring of the separate base Designed for direct-surface or electrical-box mounting Plugs into separate base for ease of installation and maintenance Separate base allows interchange of photoelectric, ionization and thermal sensors OTHER SYSTEM FEATURES: Remote test feature from the panel Walk test with address display Low standby current OPTIONS: Remote LED output connection to optional RA1 OOZ remote LED annunciator Flanged surface mounting kit Installation NH-200 Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring only. When using relay or sounder bases, consult the N100-ISO installation sheet 156-3625 for device limitations between isolator modules and iso- lator bases. Applications Use thermal detectors for protection of property. For further informa- tion, refer to 156-6522, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. Construction These detectors are constructed of fire-resistant plastic. The NH- 200 Series plug-in intelligent thermal detectors are designed to com- mercial standards and offer an attractive appearance. Operation Each NH-200 Series detector uses one of the panel's addresses (total limit is panel dependent) on the FireWarden Signaling Line Cir- cuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The NH-200 Series offers fea- tures and performance that represent the latest in thermal detector technology. DN-60980:B 6/26/2019 -Page 1 of 3 Product Line Information NOTE: "-IV' suffix indicates CLIP and FlashScandevice. NH-200: White, low-profile intelligent 135°F fixed thermal sensor, FlashScan only NH-200-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, FlashScan and CLIP NH-200R: White, low-profile intelligent rate-of-rise thermal sensor, FlashScan only NH-200R-IV: Ivory, low-profile intelligent rate-of-rise fixed thermal sensor, FlashScan and CLIP NH-200H: White, low-profile intelligent 190°F fixed thermal sensor, FlashScan only NH-200H-IV: Ivory, low-profile intelligent 190°F thermal sensor, FlashScan and CLIP INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-64V: Ivory,6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. ULIULC listed (CSFM: 7300-1653:0109) 6501-WHITE-BP: Bulk pack of B501-WHITE contains 10 B224RB-WH: White, relay base (CSFM: 7300-1653:0216) - B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) B224B1-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224B1-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) Page 2 of 3— DN-60980:B • 6/26/2019 B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base TR300-IV: Ivory, replacement flange for B2IOLP(A) base RAIOOZ: Remote LED annunciator. 3-32 VDC. Mounts to a U.S. sin- gle-gang electrical box. For use with B501 (A) and B300-6(A). M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: Color Kit (includes cover and trim ring), white, 10-pack CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack SPECIFICATIONS Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC is 0.5% to 3.5% Size: 2.0 (5.3 cm) high; base determines diameter — B300-6: 6.1 (15.6 cm) diameter - B501: 4(10.2 cm) diameter For a complete list of detector bases see DN-60981 Shipping weight: 3.4 oz. (95 g) Operating temperature range: NH-200, NH-200R Series: —4°F to 100°F (-20°C to 38°C) NH-200H Series: —4°F to 150°F (-20°C to 66°C) Detector spacing: UL approved for 50 ft. (15.24 m) center-to-cen- ter, FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing Relative humidity: 10% - 93% non-condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) Mounting: B300-6(A) flanged base, included See "Product Line Information: Intelligent Bases," if using a dif- ferent base. ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC (ON") Listings and Approvals Listings and approvals below apply to the NH-200 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULIULC Listing: S747 FM Approved CSFM: 7270-0028:0502 Iso ooi t - • • •i c_I ENIINNNS i QUALITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change odthout notice. NOTIFIER ,. reia,eiitn nvlc cn, cnn incnn,ain, recvte.. cc cincncn 12 Clintonville Road ,nunnncl in Northford, CT 06472 grvk.nnvy.n.ci ntvnnnTcnvl nc. qins nonnved. .lnvut!icnzec 203.484.7161 www notifier corn Country of Origin Mexico 0 9jl, 2 NOTFER by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:0502 Page 1 of 1 CATEGORY: 7270--HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywelI.com DESIGN: Models FST-951, FST-951H, NH-200, NH-200H (fixed temperature) and FST-951R, NH-200R (fixed temperature with Rate-of-Rise) electronic heat detectors. Suffix -IV for ivory color and -BL for black color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Models FST-951 and NH-200 (fixed temperature): 135°F. Models FST-951H and NH-200H (fixed temperature): 190°F. Models FST-951R, NH-200R (fixed temperature with rate of rise):135°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Notifier base B71OLP (CSFM No. 7300-0028:173); System Sensor bases B501, B21OLP, B300-6, B300-6-IS (CSFM No. 7300-1653:0109); 13224131, B224RB (CSFM No. 7300-1653:0126); 8200S, B200SR (CSFM No. 7300-1653:0213); B200S-LF, B200SR-LF (CSFM No. 7300-1653:238); and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev 02-14-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division JN-7001:D • Al-380 (Q NOTFFER CT -. by Honeywell CZ~411Z;rl =4n` NOT.BGI 2LX Addressable Manual Pull Station General The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels, and the NSP-25 panel. Because the NOT-BG12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-i 0 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4' (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The NOT-BG12LX will mount semi-flush into a single-gang, double-gang, or standard 4 (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NOT-BG12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The NOT-BGI2LXI Addressable Manual Pull Station The BG12TR is usually needed for semi-flush mounting with 4 (10.16 cm'1 or double-gang boxes (not with sinçle-gang boxes). Operation Pushing in, then pulling down on te hande causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in brght yellow) appears at the top of the handle, while a pertion of the handle protrudes from Ite bottom of the station. To reset the station, simply unlock The station with the key and pull the door open. This action resets lie handle; clos- ing the door aLtomatically resets the switch, Each manual statcn, on comma-id from the control panel, sends data tc the panel repreEenting the state of the manual switch. Two rotary decimal switches allow address settings (1 - 99 on NFW2-100/NFW2-100C, 1 - 50 to- NFW-50/NFW- 50C). Architectural/Engineering Specifications Manual Fire Aarm Stations shall be non-co-dad, with a key- operated reset lock in order that t'iey ma be tested, and so designed that after actual Emergercy Ope aon, they cannot be restored to normal except by use of a kE J. An operated sta- tion shall automatically condition itself sc as to be visually detected as activated. Manual stations shah be constructed of red-colored po.ycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the from of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or S3-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4(10.16 cm: square electrical box, and shall be installed :N-7c01 :D • 4r3r)12 - Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E Vol. IV. CSFM: 7150-0028:0199. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® is registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. El We cannot cover all specific applications or anticipate all requirements. IFflIN MMIFACIIIIIIING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-7001 :D • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:0199 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models NBG-12, NBG-125, NBG-I2LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-1 2-LO, NBG-I2LOB, NBG-1 2W, NBG-12LW, NBG-1 2NC, NBG-1 2WP, NBG-1 2LWP, NBG-12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBG-12SP, NOT-BG12LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-1 2WP, NBG-1 2LW, NBG-1 2W, NBG-1 2LWP, NBG-12LAO, NBG-12L0, NBG-12LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB-I/O, orWP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Monitor Modules NMM.100(A), NMM.IOOP(A), NZM.100(A), and NDM.1 00(A) for FireWarden Series General Four different monitor modules are available for Notifier's FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-con- tact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-100(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-IOOP(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeedTM is a communication protocol that greatly increases the speed of communication between analog intel- ligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. NMM.100(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 —99 on FireWarden-100- 2, 01 —50 on FireWarden-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used DN-6999:E NOTIFIER by Honeywell i. ! . r . ol NMM-100(A) (Type H) to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NMM-IOOP(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. DN-6999:E • 07/30/2015 - Page 1 of 4 Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01-99 on FireWarden-100-2, 01 - 50 on FireWarden-50. 1,115 0 ADDRESS I - 0 12 ' //)"\' 13 1l'\\V//jJ )4 LOOP ioç 5 5 TENS ONES I— Oi. LU c •O -4 -J LU •:Z -i I co The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelli- gent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two- wire initiating device circuit for normally-open-contact fire alarm and security devices. NMM-100P(A) NMM-IOOP(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. NMM-IOOP(A) OPERATION Each NMM-IOOP(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). NMM-IOOP(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75' (6.985 cm) wide x 0.65° (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. NZM.100(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address:, 01 - 99 on FireWarden- 100-2, 01 —50 on FireWarden-50. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two-wire conventional smoke detectors. It trans- mits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. NZM-100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k ed. EOL resistance: 3.91K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2014— DN-6999:E • 07/30/2015 NDM-1 00(A) Dual Monitor Module The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM-100(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPEcIFIcATIoNs Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the NDM-100(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-1 00(A), NZM-1 00(A), and NDM-1 00(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and reg- ulations. These modules are intended for power-limited wir- ing only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635. ULC: S635. FM Approved. CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-1 00). MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100). Product Line Information NOTE: "A" suffix indicates ULC-listed model. NMM-100(A): Monitor module. NMM-IOOP(A): Monitor module, miniature. NZM-100(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. DN-6999:E • 07/30/2015 - Page 3 of 4 Notifier® and FireWarden® are registered trademarks and LiteSpeedTM and FireWatchlM are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 13~. We cannot cover all specific applications or anticipate all requirements. HISINERINI a MMUFACUMNS All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notifier.com Page 4 of 4— DN-6999:E 07/30/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0230 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-1 00 control modules; and *NZM100.6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division dn-60383:A2 NC-I OOR(A) OTI F E R' Relay Module for FireWarden Series Panels by Honeywell General The NC-100R(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when activated. High noise immunity (EMF/RFl). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade entry of address: 01 - 99 with the FireWar- den-100-2(C) and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The NC-100R(A) provides two Form-C dry contacts that switch together. Operation Each NC-i OOR(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. .1 1 NC-100R(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 lJA direct poll (CLIP mode), 255 pA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (LJR=5ms) Coded 30 VDC 0.5 A Inductive (UR=2m5) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2 • 06/17/10 -Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UUULC Listed: S635. CSFM approved: file 7300-0028:230. FM approved. MEA approved: file 72-01-E, Vol. 2. Product Line Information NC-11 OOR: Intelligent addressable relay module. NC-i OORA: Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document /56-2593-001 and refer to the SLC Wiring Manual, document 52304. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so ooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. ENGINEERING fi MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made inthe U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2 - dn-60383:A2 • 06/17/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION CAL OFFICE OF THE STATE FIRE MARSHAL FIRE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY LISTEE: DESIGN: 7300-0028:0230 Page 1 of 1 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules; and *NzM1006 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILL.O, Program Coordinator Fire Engineering Division SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor a: the time ofsystem acceptance and approval. It shall be permitted to mod(/j/ ihisfornz as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 10/13/2020 Supplemental Pages Attached: n/a PROPERTY INFORMATION Name of property: State St Commons Address: 2742-2752 State Street, Carlsbad, CA 92008 Description of property: Retail/Office Name of property representative: HP Investors Address: 335 15" St. San Diego,CA 92101 Phone: Renida Tolentino Fax: E-mail: renida.tolentino@hpinvestors.com INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: JJJ ENTERPRISES Address: 115 MARKET PL, ESCONDDO, CA 92029 Phone: 760-747-3050 Fax: 760-747-7561 E-mail: INFO@JJJENT.COM Service organization: SAME AS ABOVE Address: Phone: Fax: E-mail: Testing organization SAME AS ABOVE Address: Phone: Fax: E-mail: Effective date for test and inspection contract: n/a Monitoring organization: GMS Address: 1127 LOMA AVE. LONG BEACH, CA 90804 Phone: 888-467-1119 Fax: E-mail: Account number: J71035 Phone line 1: Phone line 2: Means of transmission: Cell Entity to which alarms are retransmitted: Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: NEXT TO FACP DESCRIPTION OF SYSTEM OR SERVICE This is a: D New system 0 Modification to existing system Permit number: FPC-2020-0025 NFPA 72 edition: 2019 4.1 Control Unit Manufacturer: NOTIFIER 4.2 Software and Firmware Firmware revision number: 26 4.3 Alarm Verification Number of devices subject to alarm verification: N/A Model number. NFW-100x D This system does not incorporate alarm verification. Alarm verification set for seconds (p.1 of 3) FNF SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: I20VAC Overcurrent protection: Type: CIRCUIT BREAKER Branch circuit disconnecting means location: HOUSE PANEL 5.1.2 Secondary Power Type of secondary power. BATTERIES Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 HOURS Control panel amps: Amps: 20 Number: HM-37 In alarm mode (minutes): 5 AMPS 15 MINUTES 5.2 Control Unit This system does not have power extender panels 0 Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Pathway Typo Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line N/A N/A B I Device Power N/A N/A B 1 Initiating Device N/A N/A B Notification Appliance N/A N/A B 1 Other (specify): N/A N/A N/A N/A 7 OCREIWE A.II.IIIIif'IAr1c ANN-80 KEYPAD 8. INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations I ADDRESSABLE ALARM DRY CONTACT Smoke Detectors 5 ADDRESSABLE ALARM/SUPV PHOTOELECTRIC Duct Smoke Detectors 0 N/A NIA N/A Heat Detectors 1 ADDRESSABLE ALARM HEAT Gas Detectors 0 N/A N/A N/A Waterfiow Switches 1 N/A N/A DRY CONTACT Tamper Switches 2 ADDRESSABLE SUPV DRY CONTACT (p. 2 of 3) SYSTEM RECORD OF COMPLETION (continued) M,111011 iir.ii Type Quantity Description Audible 0 N/A Visible 0 N/A Combination Audible and Visible 0 N/A 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices N/A HVAC Shutdown N/A Fire/Smoke Dampers N/A Door Unlocking N/A Elevator Recall I CAR - 2 FLOORS Elevator Shunt Trip 1 INTERCONNECTED SYSTEMS This system does not have interconnected systems. 0 Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor7 This sy as speci td herein hay,Jn installed according to all NFPA standards cited herein. Signed: 4i _'/ Printed name: JIM MCKINLEY Organization: JJ ENT Title: PROJ MGR 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: SAME AS ABOVE Printed name: Organization: Title: 123 Acceptance Test Date and time of acceptance test: 10/13/2020 Installing contractor representative: Jim McKinley Testing contractor representative: Jim McKinley ( ACCEPTANCE TESTING) Property representative: AHJ representative: Date: 10/13/2020 Phone: 760-747-3050 Date: Phone: (p.3 of 3)