Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5605 GRAND PACIFIC DR; ; FA100065; Permit
8/17/22, 9:58 AM FAI 00065 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FAI 00065 5605 GRAND Job Address: PACIFIC DR Permit Type: FALARM Parcel No: 2111300200 Lot #: 0 Status: ISSUED Applied 11/2/2010 Approved: 11/2/2010 Reference No.: Issued: 11/2/2010 PC #: Inspector: Project Title: VILLAS 52/TIMESHARE MONITORING SYSTEM PLAN CHECK & INSPECTION Applicant: Owner: KITE ELECTRIC INC. GRAND PACIFIC CARLSBAD L P STE B 11 MARCONI 5900 PASTEUR CT #200 IRVINE, CA CARLSBAD CA 949-380-7471 Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 1/1 PA10006G +-p1kiooc GE EST Are &! G:Gety Security Control Panels Overview GE Security's QS1 life safety control panel brings big-system intel- ligent control to small applications. Designed for easy setup and simple installation, QuickStart lives up to its name in every respect. QS1's exclusive QuickStart auto-learn function, and the option of configuring the panel using convenient front panel programming or from a PC, makes short work of system setup. Devices come on-line in no time as well, thanks to QS1's built-in barcode scanner port. A simple pass of the optional scanner is all it takes to store device in- formation in the QuickStart database. The scanner can also be used for quick and easy text entry when assembling custom messages. QS1's setup routine is deceptively simple, considering this sys- tem's robust features. Supporting up to 250 intelligent detectors and modules, QS1 takes full advantage of GE Security's exclusive Signature Series technology, which provides electronic addressing, automatic device mapping, environmental compensation, and true multisensor detection. QuickStart's innovative design makes it easy to add a dialer or extra auxiliary relays. Quick-Lok option cards snap onto QS1's easily-ac- cessible DIN mounting rails. QS1 also supports as many as eight remote annunciators and up to 30 programmable front panel switches with dual LEDs for system control and display. QS1 is as simple to operate as it is to set up. Its large 14-line backlit LCD display provides easy-to-understand details concerning up to 1,000 system events, while bright system status LEDs and large, tactile control buttons present the user with a clean, crystal clear interface. Four password levels limit control and information retrieval to authorized personnel. A priority access keyswitch gives Level 2 ac- cess without a password to management and emergency personnel. Standard Features Supports up to 250 Signature Series intelligent devices Combines the Signature intelligent releasing module with Signa- ture multisensor detectors for reliable suppression Failsafe mode ensures uncompromised reliability Class A (Style 7) or Class B (Style 4) wiring options Capacity for eight serial annunciators Four built-in system relays Optional dual line dialer supports Contact ID and 4/2 formats Three methods of programming: QuickStart "auto-learn," front panel and personal computer (PC) Supports optional barcode scanner for direct device data entry Optional bank of 30 front panel switches with dual LEDs Up to 20 adjustable pre-alarm settings for Signature smoke detectors Wallboxes available in red or gray with optional trim ring for semi-flush mounting. Large 14-line (224 character) backlit LCD display Four password levels, plus priority access keyswitch Message routing by event type or by individual message Alarm sensitivity by time of day or manual selection 1,000 event history buffer, plus alarm history counter 6 amp Power Supply, 4.75 amps available for external use Envoy graphics compatible Compare utility identifies system changes and simplifies testing Intelligent Single Loop Life Safety FL Control Panel (k QSI. .i.. ,.. IMEA -. Data Sheet 85005-0113 issue 6 -. ...... Not to be used for installation purposes. Page 1 of 8 88 .4 m) 15' (45.72 cm) i.iui.imT 2.2" (5.6 cm) 6. 2 8 1 . 1 m) Optional Vandal- Resistant I Door il 1-J Semi-flush mount- ' Wall (4.27cm) tag requires an Wail -°'.., ' optional trim nag, which adds 3/4" Semi-flush Surface to all sides of the Mounting Mounting pane!. Application Thanks to its flexibility and simple setup and operation, QS1 is ideal for new installations in schools, apartment buildings, hospitals, of- fice buildings, and retail facilities. The benefits brought by QS1 to retrofit applications underscores the true potential of this powerful system. As an intelligent panel, QS1 supports Signature Series devices, which can use existing wiring in most retrofit applications. This makes upgrading from a conven- tional system to analog control a simple operation with minimal disruption to normal operations at the site. Which Quickstart Panel is right for you? QSC QS1 Q54 Signature Series devices supported 0 lx 250 L x250 Conventional Class B circuits supported 3x 16 0 3 x 16 Conventional Class A circuits supported 5x8 0 5x8 LCD display (lines x characters) 4x20 14x 16 14x 16 Optional Zone Switch/LEDs on front panel 2 x 30 1 x 30 2 x 30 Option cord spaces 5 or 12 1 5 or 12 For more information, see Data Sheet ... 85005 -0112 85005 -0113 85005 -0114 CPU / LCD Display The QS1 front panel display provides 14 lines by 16 characters of text detailing event, device, diagnostic, and programming infor- mation. Its large backlit LCD screen is easy to read and always provides at-a-glance indication of the system's state of operation. The CPU/Display Unit houses the CPU card and mounting space for one optional LED/Switch card. Lj 1 00 i8i.585 5tfl,' cot SkI'S septic sotw 0' 504 Sn C5504 pet t5i tp't ttp sue 580L COO 00,' 005770 0J , Stoke Display with two alarms shown Specifications Control Panel Standby Current: 199 mA Alarm Current: 235 mA Remote annunciator Standby Current: 154 mA (Full control versions) Alarm Current: 166 mA SRA Series Standby Current: 70 mA Alarm Current: 90 mA Operating Temperature: 32-120°F (0-49 °Cl environment Humidity: 93 %RH, non-condensing Failsafe Mode If the CPU loses communication with other circuit cards, the power supply card continues to monitor the system for any alarm events. If an alarm occurs on any device or circuit during a communica- tions failure, the power supply activates all alarm outputs and instructs the dialer to transmit a default alarm message to the monitoring station. 14'/, 136.2 cm) Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 2 of 8 Class A Wiring +—+— CH2 CH1 0 CH2i-100T 0 CH2i1iOUT 0 CHSI—)IN 0 CH2(+)IN 9 CH1(—)OUT 9CHIiniOUT 4-0 _CH1i—iIN CHI (-)IN 9_a24VDC OUT 9 COMMON OUT u24vDCIN h_O COMMON IN LLGO. - - F -------- - 9 CH2i—iOUT 9_CH2(u)OUT CI'42i—)IN CH2i+iIN I CHI(—)OUT 9 CHl(+(OUr CHI (—)IN CH1i+iIN 9_+24VDC OUT 9 COMMON OUT +24VDC IN COMMON IN 0 CH2i—)OUT 0 CI'(2i1iOUT I 0 CH2/—)IN 0 cH2i+/IN I 0 CHI (—)OUT 0 CHI inioUT CHI (—)IN I CHI(+)IN 0 +24VDC OUT COMMON OUT I +24VDC IN COMMON IN EARTH ONO 0 CH2i—)OUT 0 CH2i+iOUT CH2i—/IN CH2iniIN 0 CIlli—/OUT 0 CHIiuiOU1 CHIt—uN CHI (-)IN 0+24VOC OUT O COMMON OUT +24VDC IN COMMON IN EARTH GNO PS6 RS485 - R5485" LISTED 24 VDC SUPPLY 24 VDC + 24V0C— S Class A Wiring NT"A RS-485 CARD CH2— 0 CH2. 0 CHI— 0 CH2c 0 LISTED 24 VDC SUPPLY 74 VDC 1 0 24 VDC - Remote Annunciators QS1 supports up to eight remote annunciators, which provide mirrored or customized annunciation of front panel messages and status indicators. Two models are available: The QSA Series, and the SRA Series. QS1 Annunciator QS1 remote annunciators connect directly to the PS6 Power Supply Card or an external 24 Vdc filtered supply. They are available with wallboxes for flush or surface mounting Annuncia- tors are available with one annuncia- tor option space for a display card with 30 dedicated switches and LEDs. See the Ordering Table for more information. Class 8 Wiring F24VDTRISER PS6TB1_13> PS6TB1-l' SRA Annunciator The QuickStart SRA Remote Annunciator is a single-loop standalone unit that can be powered by the control panel or by an approved power supply. Annunciators support Class A or Class B connection to the sys- tem RS-485 data line, but do not provide ground fault isolation. The SRA annunciator includes an RJ-12 modular jack to allow sys- tem database downloads from a laptop computer. Connection requires a programming cable (model number PROGCABLE-1, ordered separately). Annun- ciators are mounted to North American 2-gang or 4-inch square electrical boxes. Mounting a Field wiring Electrical box RIIIIUIIUIdLOI iTiY1 Class 8 Wiring Annunciator Annuncia Dimensions Mode) Height Width Depth QSA-1-S 7.6" (19.46 cm) 14.25" (36.20 cm) 2.9 (7.3 cm) QSA-1-F rough in) 6.56" (16.66 cm) 13.25" (33.66 cm) 2.1" (5.33 cm) QSA-1-F finished) 7.8' 19.81 cm) 14.42" (36.63 cm) 1.38" (3.49 cm) Rough-in dimensions reflect the size of the cabinet where it enters the wail. Finished dimensions reflect the size of the cabinet that protrudes from the wall. XGD Graphics Driver Card The XGD Graphics Driver Card is an interface device that connects a QuickStart annunciator to an Envoy Graphic Annunciator. The XGD provides the electronics required to support 24 LEDs and 12 switches on the Envoy display panel. Multiple XGD cards can be chained together in one graphic annunciator cabinet to control larger displays. The QuickStart SRA Series annunciators can support o maximum of six XGD cards. Data Sheet 85005-0113 Issue 6 Motto be used for installation purposes. Page 3 of 8 Operation 3,~,4)f 5', 6; 7)1,8 fl9 Indicators 7 Text display and controls: Displays + system messages, E status information, and programming menus. Arrow buttons move the display cursor. Alarm LEO: Indicates a fire or life threatening emergency. Supervisory LED: Indicates an off-normal condition with the fire suppression system or related equipment. Disable/Test LED: Indicates part of the system is disabled or be- i ng tested. Disabled components also signal a system trouble. Monitor LEO: Indicates the operation of an ancillary system function (door closures, fan pressure switches). Trouble LED: Indicates an off-normal condition or wiring fault that compromises the integrity of the system. Ground Fault LED: Indicates a ground fault in the system wir- ing. Ground faults also signal a system trouble. cpu Fail LED: Indicates an unexpected reboot or failure with the microprocessor. CPU failures also signal a system trouble. Power LED: Indicates the panel has power. Help button: Provides additional information about the device selected on the display. Status button: Displays the Status Menu from which you can identify active or disabled points in the system. Panel Silence/Acknowledge button and LED: Acknowledges all events posted in the display queues and turns off the panel buzzer. The panel silenced LED indicates that off normal events have been acknowledged. Controls A- Controls Reset button: . . Allows devices or -. .. zones in alarm or r trouble to restore - - to their standby _. condition. The LED indicates that the C C panel is resetting. Alarm Silence button: Turns active notification appliances off depending on panel programming. Pressing Alarm Silence a second time turns them back on. The LED indicates that the panel is in alarm and operating with notification appliances turned off. Drill button: Activates notification appliances depending on panel programming but does not place the panel in alarm. The LED indicates that the panel is in Drill Mode. Menu button: Displays the operator menus. Delete button: Returns to the previous menu or backspaces the cursor. Enter button: Press the Enter button to accept information or continue to the next item. Numeric keypad: Numbered buttons for entering values and making menu selections. Barcode scanner jack: Input for optional barcode scanner. Priority Access keyswitch: Enables control functions reserved for access level 2 and above without requiring a password. Data Sheet 85005-0113 issue 6 Not to be used for installation purposes. Page 4 of 8 Typical Wiring RM UM CR Class A Signature Data Fire Damper c Circuit Class A Signature Data Circuit Class A Notification Appliance Circuit with Genesis Signals and Signal Master for Independent Horn and Strobe Control and Synchronization over two conductors. 2nd Floor C) Class B Notification Appliance Circuit pplian \ - vd 21 Critical Process Monitoring - with Control Walerflaw, Switch T2 L1- C prinkler S - Supervisory Switch rLiE1 Elevator Capture ?Y ??Cl sANoton Appliance Circuit QS1 Panel Class B Signature Data Circuit Horn and Strobe Synchronization with Audible Silence Class B Notification Appliance Circuit with Genesis Signals and cis m Signal Master for Independent Horn and Strobe Control and Synchronization over two conductors. Signature Fir Circuit (1 pr.) Damper 2nd Floor I LttNO I Enhanced Integrity End-of-Line L!5J Horn-Strobe Resistor Genesis E!3 Programmable LJ Horn-Strobe I/O Module Genesis Universal C Signal Master I/O Module 2 Smoke Dual Circuit Detector Input Module 2-Wire Control Relay &t) Smoke Detector Module 5' Smoke Detector Signal !rnyi with Relay Base Module Smoke Detector Signal Module iI with Isolator Base (synchronization) Manual J Riser Monitor Pull Station Module Junction WM71 Monitor Module Box C) Horn and Strobe ________ Control (2 pr) cdi s Critical Process . Waterflow. Monitoring Switch ' 1-- JCT2] Sprinkler 55Of Switch - F _* Elevator Captu- Notification Appliance Circait cR Horn and Strobe Synchronization with Audible Silence QS1 Panel i-lore wiring suggestions con be found in the QS! Fire Alarm Control Panel instalia- ton, Operation, and Maintenance Manual, P/N 3100184. Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 5 of 8 Standard Components and Option Cards QS1 panels come standard with a CPU/Display Unit, an SLIC Signature Loop Controller, and a PS6 Power Supply (see ordering information for details). Available QS1 option cards provide dialing capability or extra relays for ancillary control. Quickiok option cards snap onto DIN mounting rails for fast, no-fuss installation. One op- tion card space is available. Cabinet with option CI and batteries instal PS6 Power Supply Cord Standard Component Description The PS6 provides primary dc power to all the rsi circuit cards installed in the cabinet. There are four 24 Vdc power output circuits - three for powering auxiliary applications, and one for powering four-wire smoke detectors - and a 1..- - charging circuit for standby batteries. The PS6 also provides common alarm, supervisory, and trouble relays, as well as a fourth relay that is user programmable. TB2 Wiring RNN.NN,,,S+b. BATTPWR NC. AUX ' nuxi nu COM x3 cm 1B2 1. L L. NE— ~ RE— I SMOKE RS485 R5232 Relay 1: Form C. contacts change position when the control panel processes an alarm signal and remain changed until all active alarm inputs restore and the control panel resets. Relay 2: Farm A. Contacts change position when the panel processes a supervisory signal and remains changed until all active supervisory inputs restore. Relay 3: Form A. Contacts change position when the panel loses power or processes a trouble s:griol and remains changed until power returns of the trouble clears. Relay 4: Form A. Relay clones and opens according to panel programming Smoke/Accessory Power: Jumper setting determines if the 24 Vdc is constant or resettabie. SLIC Signature Loop Intelligent Controller Description The SLIC provides one Class A or Class B data ç -• TB1 circuit (loop) for connecting Signature Series detectors and modules. The SLIC also provides two programmable Class A or Class B natifica- r tion appliance circuits (NACs) for connecting polarized 24 Vdc notification appliances such as horns and strobes. QS1 supports one SLIC. Wiring Class A OwN A OUT IN LOOP Ill * - * - A*A- B.B— H H 00000000T82 TB2 HPH ?' Signaling Line Circuit I and NACu are super- 0 0 0 0 0 0 0 0 181 Ci vised and power- 8+ B- A* A- 5* B- Ax A- limited NAC 1 NAC 2 Class A Specifications Main supply circuit AC input: 115 or 230 Vac, 50/60 Hertz DC input: 24 Vdc batteries Charge current: 2 amps Battery charging circuit Charge capacity: 40 amp hours JUL) 30 amp hours IULC) Smoke/Accessory Voltage: 24 Vdc, regulated Current: 250 mA power output circuit Wire size: 12 to 18 10.75 to 2.5 mm') Auxiliary power output Quantity: 3 circuits Voltage: 24 vdc full wave rectified Current: 1.5 amps each Style: Form C Common alarm relay Contact rating: 1 amp Wire size: 12 to 18 AWG 10.75 to 2.5 mm21 Trouble, Supervisory Style: Form A NO) and programmable Contact rating: lamp relays Wire size: 12 to 18 AWG 10.75 to 2.5 mm2) Operating environment Temperature: 32 - 120° F (0 - 49°C) Humidity: 93 %RH, non-condensing Current requirements Standby current: 72 mA Alarm current: 96 mA Standard Component Specifications Configuration: Class B (Style 4) or Class A (Style 7) Signaling line Capacity: 125 Signature detectors circuit 125 Signature modules Wire size: 18 to 12 AWG 10.75 to 2.5 mm21 Circuit resistance: 65 ohms Circuit capacitance: 0.3 Jf Configuration: Class B or Class A Notification Output voltage: 24 Vdc, nominal appliance Output Current: 2.0 A at 24 Vdc for #1 circuits #1 and 0.8 A at 24 Vdc for #2 and #2 Wire size: 18 to 12 AWG (0.75 to 2.5 mm') End of line resistor: 10k ohms, ½ W NAC power Voltage: 24 Vdc, nominal input circuit Wire size: 18 to 12 AWG 0.75 to 2.5 mm2) Operating Temperature: 32 - 120° F 10- 49° Cl environment Humidity: 93 %RH, non-condensing Current Standby current: 33 mA requirements Alarm current: 57 mA (Both NACs on) Card spaces Requires one card space. Data Sheet 85005-0113 issue 6 Not to be used for installation purposes. Page 6 of 8 Operating Temperature: 32 - 120° F 10-49°C) environment Humidity: 93 %RH, non-condensing Current Standby current: 11 mA requirements Alarm current: 18 ma per active relay Card spaces Requires one card space. Wiring oR5 frT, /\ / \ A I L I............ .... - - DLD Dialer Option Card Description The DLD is a ULl/ULC listed dual line Digital Alarm Communicating Transmitter IDACTI. It provides two phone line connections for send- ing system messages to a compatible Digital Alarm Communicator Receiver. The DLD supports 4/2 and Contact ID formats. It occupies one card space on the chassis rail. Wiring (E RING Zin B1 IORECN) TO PHONE LINE CONNOCIOR CRLF OOFFN') PIR 'ONR; TOR FOR OP ROT TIP ONG TIP ORG TIP OTT IN OUT IT OUT LINE LINE2 ZR8 Relay Card Description The ZR8 provides eight dry-contact relays that can be independently configured as Form A or Form B relays. It occupies one card space on the chassis rail. Specifications Operating Temperature: 32- 1200 F (0-49°C) environment Humidity: 93% RH, non-condensing Current Standby: 13 mA Alarm: larm: 20 mA Dialing: 26 mA Phone Lines Two loop start lines on switched telephone network. Pulse or DTMF dialing. Wall Connector RJ31X/CA31A equiv. or RJ38X/CA38Aequiv. Communications Protocol Contact ID ISIA DC-05),4/2 (SlA DC-02 P3). Programming Via QuickStart, Front Panel or PC. Communications Communications Canada CS-03FCC/CFR 47 Parts Compliance 15 and 68, NFPA 72, ULI 864, ULC 5527-M87 Receivers Signals can be transmitted to either or both of two receivers. Telephone #s Two 24-digit numbers per receiver. Card spaces Requires one card space. Option Card Specifications Style: Form A IN/al or Form 8 IN/C) jumper configurable) Output relays Contact rating: 1 amp © 30 Vdc resistive. Wire size: 18 to 12 AWG (0.75 to 2.5 mm') X485 Class A RS 485 Card and QS 232 Port Description Wiring The NT-A, which includes the X485/ RS-485 card and QS-232/UART port, provides one Class A serial remote an- nunciator bus for connecting remote annunciator panels. Control panels require the X485 card and QS-232 port, which also serves as a laptop or printer port. The X485 occupies one card space on the chassis rail. The OS- + - - 232 port plugs into the panel CPU. CH2 Ciii SL30, SL30-1, SL20L5S, SL30L LED/Switch Cards. Description The SL30 and SL30-1 provide thirty circuits for zone annunciation. Each circuit comprises two LEDs and a push button switch. The SL30 push I 'U button switches are numbered from 1. to 30 and the SL30-1 push button switches are numbered from 31 to 60. The SL20L5S provides 20 cir- cuits for paint annunciation and five circuits for custom control functions. The SL30L provides 30 circuits for point annunciation. SL20L5S and SL30L circuits are labeled using inserts provided with the cards. Option Cards Specifications T Wire size 12 to 18 AWG (0.75 to 2.5 mm') twisted pair 16 twists per foot minimum) J Circuit resistance 100 Ohms Circuit capacitance 0.4 pF Operating Temperature: 32 - 1200 F 10- 49° Cl environment Humidity: 93 %RH, noncondensing Current Standby: 60 mA requirements Alarm: 60 mA Card Spaces Requires one space for the NT-A Option Cards Specifications Temperature: 32- 120°F 10-49°C) Operating environment Humidity: 93% RH, non-condensing Current requirements Standby: imA Alarm: 0.75 mA per active LED Data sheet 85005-0113 issue 6 Not to be used for installation purposes. Page 7 of 8 Colors G = Grey enclosure 1230v or 115vl R = Red enclosure 1115v only) Examples QS1-1-G-2-SP = QS1 basic package with one option card space, grey enclosure, 230v transformer, Span- ish language. QS1-CPU-FR = QS1 CPU/display, French Canadian. Accessories PT-1S BC-1(R) MFC-A 0 P34 RPM 2-CTM API-8/232ME BPS6A BPS1OA CDR3 - GE Ordering information Part Ship Security Number Description Basic Package Enclosure, SLIC, Power Supply, CPU and Display... U.S. QS1-1-G-1 Single loop system. 1 option card space. Gray enclosure, 115v transformer. 17.0 17.711 T 888 378 7379 QS1-i-R-1 Single Loop System.iopbo.n card space. Red enclosure, 115v transformer 17.0 17.71 Note: ELIC Card includes One Signature Loop Intelligent Controller for up to 250 devices and one Class A or two Class B NACs. Canada 1519376 2630 Enclosure Accessories F 519 376 7258 QS-1-VR Vandal-resistant cabinet door, gray 3.011.361 Asia QS-1-VR-R Vandal-resistant cabinet door, red 3.011.361 T 852 2907 8108 TRIM-1 Trim Kit - gray 5.0(2.27) F 852 2142 5063 TRIM-1R Trim Kit - red 5.0(2.27) Australia T 613 9259 4700 OpticnCards F 613 9259 4799 - .......................... -- ............................- ............- ... .................... .. ... -................... DLD Dual Line Dialer. Supports 4/2 and Contact ID formats -.-.-. .................... 1.0 10.451 Europe ZRS Relay Card. 8 programmable Form A contacts 1.010.451 1 32 2 725 1120 F 32 2 72186 13 Dicpl'iv Opt uric Latin America 5L30 Annunciator module. Numbered 1 t 30. Two LEDs and one switch perzone 1.0 10.45i 1305 593 4301 F 305 593 4300 Annunciator module. 20 circuits for point or zone annunciation, 5 SL20L5S 1.0(0.451 circuits for custom functions. Circuits labeled with insert card. i www.gesecurity.com © 2006 General Electric Company All Rights Reserved QuickStarl and Signature Series ore Trademarks of GE Security. Ordering options Apply to basic packages and CPU/displays only) Languages No suffix = American English SP = Spanish 1230v or 115v1 PG = Portuguese (230v only) FR = French Canadian (120v only) Power Supplies 1 = 115v transformer 2 = 230v transformer SL30L Annunciator module. 30 circuits. Circuits labeled with insert card. 1.0)0.45) 051-CPU-1 Single Loop CPU/Display, one annunciator option space 4.0 (1.81) ESTSRA1 Intelligent/Conventional CPU/Display with integrated LCD and control 4.0 11.811 switches. 4 square box mount. NT-A RS-485 option card. Required for Class A remote annunciation. Includes 10(045) UART card, QS-232 UART option card. Plugs into CPU. Required for PC Programming / 1.0(0.45) printer port. Included in NT-A package Remote Annunciator Cabinets Ic/tv Interface Assembly; Require CPU/Display)... QSA-i-S Surface Remote Annunciator Cabinet. Space for one 5L30 display card. 4.0(1.81) QSA-i-F Flush Remote Annunciator Cabinet. Space for one SL30 display card. 4.0)1.81) QSA-' - -SVR Surface Remote Annunciator Cabinet. Vandal Resistant. Space for one 4011811 SL30 display card. QSA-:-F-VR Flush Remote Annunciator Cabinet. Vandal Resistant. Space for one 4.0(1.81) SL30 disolav card. Programming Tools OS-CU QuickStart Panel Configuration Utility. 1.0(0.45) QS-Scan QuickStart scanner and programming guide. 2.010.911 Progcable-1 Scanner port upload/download cable 1.0(0.45) 260097 Programming cable (PC to QSC, QS1, 1.0(0.45) SystemPrinter - Desk top Style 14.0(6.351 Battery Cabinet. Room for one 40 Ah or two 24 Ah batteries. 22.0 (9.98) MultiFunction Cabinet. 7.0(3.1) RS-232 Isolator Module. 3.0(1.36) Reverse Polarity Module. 3.0(1.36) City Tie Module. 1.0(0.45) Alphanumeric I'll Pager Interface. 11.0(5.01 6.5 Amp Booster Power Supply, 110 V 13.015.9) 10 Amp Booster Power Supply, 110 V 13.0(5.9) PSNI Coder Module 1.0 (0.45) 0 imagination at work Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 8 018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:0207 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Brandenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 Fax (941) 309-8123 Email: rhonda.micochero@ge.com DESIGN: Models QSC, -QS1 and -QS4 fire alarm control units, followed by -1 or -2 followed by -BR, -SP, -FR, -PG or no suffix. Local, local with shunt, auxiliary, remote station, releasing service or central station. Power limited. Non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterflow, and sprinkler supervisory service. System Components: QSC, QS1, Q54 Control Units 7200001-01, -02; 7200004-01, -02 Enclosures 7200005-01, -02 Enclosures PS6 Power supply ZB16-4 Class B zone card ZA8-2 Class A zone card DLD Dialer (DACT) card ZR8 Relay card NT-A Class A, R5485 communications card Q5232, 232 Port for download or printer functions SL30 LED/Switch card with switch 1-30 SL-30-1 LED/Switch card with switch 31-60 SLIC Signature expansion loop card. QS-1-VR, -R, QS-2-VR, -R Vandal resistant doors SL30L LED Cards 30 Zones SL20L5S LED/Switch Cards 25 Zones RATING: 120/220 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Units can also generate the temporal code pattern fire alarm signal as required per NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. This control unit meets the requirements of UL-864, *9th Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Formerly 7165-1591:207 and 7165-1388:237 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed '\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division COOPER Notification POWERPATHTM NAC POWER SUPPLIES : '4 PS-EXP PS-6 PS-8 Description The Wheelock Series PS-6 and PS-8 are 24VDC, filtered and regulated, supervised remote power supply/battery chargers are used for supervision and expanded power driving capability of Fire Alarm Notification Appliance Circuits. The PS-6 provides 6 amps of power distributed across 4 outputs, while the PS-8 provides 8 Amps across 4 output. In addition the PS-8 provides additional room in the chassis for accessories like an Addressable Control Module, with mounting studs. The Power Supplies may be connected to any 12V or 24V (FWR or DC) Fire Alarm Control Panel (FACP) by using a Notification Appliance Circuit (NAC) or a "Dry Contact". Primary applications include NAC expansion (supports ADA requirements) and auxiliary power to support system accessories. This unit provides filtered and regulated 24VDC, up to four (4) Class "B", two (2) Class "A", or two (2) Class "B" and one (1) Class "A" Notification Appliance Circuits. With the optional plug-in PS-EXP module the unit supports (8) Class "B" or (4) Class "A" Notification Appliance Circuits. Additionally, an auxiliary power output of 2.5 Amps (disconnected upon AC power loss or an alarm condition) or up to 0.240 A of constant power on the PS-8 and 0.075 A of constant power on the PS-6. The Wheelock Power Supplies can accommodate 7 or 12 AH batteries inside its lockable chassis. Using an external battery cabinet it can charge up to 33 AH batteries (pending UL testing). Two FACP NAC circuits or two "Dry" contact initiating circuits can be connected to the inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. Each output is rated at 3.0 Amps (Class "B") or (Class "A") and can be programmed to generate a steady or Code 3 Temporal Horn sound and a strobe output under alarm condition. Total load for the PS-6 and PS-8 NAC circuits must not exceed the power supplies rated output. The Power Suppliesunder non-alarm condition provides independent supervision for Class "A" and Class "B" FACP NAC circuits. In the event of circuit trouble, the FACP will be notified via the POWERPATH steered input (INi or IN2). In addition there are two sets of trouble reporting terminals, one used for AC power loss reporting and the other for all troubles. The AC power loss reporting, on the common trouble terminals and on INi or IN2, can be delayed for either 30 seconds or 170 minutes. The AC power loss terminals will always report the trouble within 1 second after loss of AC power. 0 Ik <g> MA APPROVED 151.92-E The PS-6 and PS-8 Power Supplies are UL Listed under UL Standard 864, 9th Edition to be used with any 24 volt Listed Regulated notification appliances. They include the capability to synchronize Wheelock strobes and horns and to silence the horn signal when horn/strobes are operating on two wires. Approvals Approvals Include: UL Standard 864, 1481, California State Fire Marshal (CSFM), Factory Mutual (FM) Pending: New York City (MEA), Chicago (BFP) See Approvals by model in Specification and Ordering Information Compliant with NFPA 72 Inputs 120VAC, 50/60Hz, 4.25 Amps (PS-6/8) and 5.32 Amps (PS-8) Operating Power in Alarm 240VAC, 60Hz, 2.42 Amps (PS-6E and 3.22 Amps (PS-8E)' Operating Power in Alarm 24VDC Battery Backup Connection Two (2),12V or 24V NAC Initiating Circuits (8-33V at 5mA) FWR or DC Two (2) "Dry" Contact initiating Circuits Accepts two (2) Class 'A" or two (2) Class "B" circuit inputs Built in battery charger for sealed lead acid or gel type batteries ...Features continued on next page Outputs NAC outputs are 24VDC, 3.0 Amps each, power limited 8 Amps on PS-8 and 6 Amps on the PS-6 total alarm current Capable of four (4), Class "B" circuits Capable of two (2) Class "A" circuits Capable of one (1) Class "A" circuit and two (2) Class "B" circuits Capable of (8) Class "B" or four (4) Class "A" circuits with optional PS-EXP module Temporal (Code 3), constant voltage output, Wheelock Sync output or True input to output follower mode Built-in Wheelock synchronization mode that can be fed to any or all of the output circuits Input and output can be synchronized with "IN>OUT SYNC" mode (SM, DSM, 2nd POWERPATHTM or FACP with synchronization protocol is required) Audible silence capability Filtered and electronically regulated output 2.5 Amp auxiliary power limited output with reset capability. (Removed upon AC loss or alarm. Automatic reset 30 seconds after AC power returns or the alarm condition is over) or 0.075 Amps (PS-6) or 0.240 Amps (PS-8) of auxiliary power limited output which remains on during AC loss or an alarm condition when configured for 24 hour battery backup Supervision Compatible with 12V or 24V (FWR or DC) FACP Signaling appliance circuits are supervised and steered to either INi or IN2 10K Ohm, 1 Watt (Wheelock Model #MPEOL) End of Line Resistor (EOLR) for supervision of all outputs 37 distinguishable trouble diagnostics AC loss trouble reported over a separate set of contacts (delay of 1 second) All troubles are reported over the common trouble contacts (AC loss can have a delay of 30 seconds or 170 minutes) Automatic switchover to standby battery when AC fails Thermal and short circuit protection with auto reset Input and output status LED indicators AC fail supervision Battery presence and low battery supervision Ground Fault Detection, with diagnostics to indicate which circuit fault is on Latching LED's for NAC trouble annunciation and Diagnostic trouble LED's (latching can be disabled) Power Not Battery Dependent Automatic switch over to standby batteries when AC fails Supports sealed lead acid or gel type batteries Fused battery protection Thermal and short circuit protection with auto reset Supports both 7AH or 12AH batteries in the same cabinet POWERPATH TM Operating Modes (refer to Installation Manual): Normal Mode: Provides constant 24 VDC output upon initiation by a voltage to input INi or lN2 or by a contact opening on DRY1 or DRY2. The unit returns to standby mode when the input is deactivated. Wheelock Sync Mode: Provides signals for synchronization of patented Wheelock audible and strobe notification appliances. Audibles can also be silenced in this mode while the strobes continue to flash. ln>Out Sync Mode: Accepts a synchronization signal on the input to provide a coded output or synchronized output. This signal may come from a FACP, another POWERPATH or a Wheelock SM or DSM synchronization module. Caution: Do not use strobes on coded output circuits. True Input Follower Mode: Accepts a coded signal on the input to provide a coded output with the same timing as the input. The signal may come from a FACP, another POWERPATH or other coded source. Caution: Do not use strobes on coded output circuits. Temporal Mode: Codes the output voltage in a code-3 temporal pattern to drive audible appliances such as horns, bells or chimes. Caution: Do not use strobes on coded output circuits. Specifications and Ordering Information Model Number Code Order Input Voltage/Current Approvals - UL CSFM FM PS-6 105530 6 amp, red enclosure X X X PS-613 100257 6 amp, black enclosure X X X PS-8 105531 8 amp, red enclosure X X X PS-813 105830 8 amp, black enclosure X X X PS-6EXP 105083 6 amp power supply with preinstalled expansion module X X X PS-8EXP 105084 8 amp power supply with preinstalled expansion module X X X PS-EXP 105534 4 class B or 2 class A expansion module X X X PS-EXP-RETRO 105527 Field upgrade kit for models prior to January 20101 X X X Input Circuit Input voltage Range Input Voltage and Current 8 to 33 VDC = Approved = Pending Input Current @ 12 VDC 0.005 amps =Contact Technical Input Current @ 24 VDC 0.005 amps upport for addition nforamation on upg Output Circuit Output Voltage and Current ptions Four (4) Class B or 24 VDC @ up to 3 amps per curcuit (optional PS-EXP module necessary) Two (2) Class A or One (1) Class A and Two (2) Class "B" or 8 Class Bor4 Class A Continuous duty up to 3 Amps per circuit, up to 4 Amps maximum per panel Standby Current 0.129 Amps Alarm Current 0.129 Amps Primary PS-6 (120 VAC models) 105 to 130 VAC, 50/60 Hz @ 4.25 Amps Primary PS-8 (120VAC models) 105 to 130 VAC 50/60 Hz @ 5.32 Amps Primary PS-6E (240 VAC models) 210 to 260 VAC, 50/60 Hz @ 2.42 Amps Primary PS-8E (240 VAC models) 210 to 260 VAC 50/60 Hz @ 3.22 Amps Secondary Power Charging Capacity 32 Amp hours @ 0.750 Amps per hour Enclosure can house up to two 12 AH batteries Aux Output CP Mode PS-6 up to 75 mA PS-8 up to 250 mA MP Mode 2.5A during non alarm Model Dimensions Weight Comments PS-6/PS-613 17"H x 13"W x 3.5"D 11.5lbs. (Ship) 9.41bs (Unit) Small profile PS-8/PS-8B 17"H x 15"W x 5.5"D 17.71bs (Ship) 15.61bs (Unit) Additional room for modules PS-EXP 4.3"H x 3.7"W x 1 "D llb. (Ship & Unit) Plugs into main pcb on all -models ade Architects and Engineers Specifications The power supply shall be Wheelock POWERPATHTM Series PS-8, or equivalent. The unit shall be stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC). The unit shall be UL 864 Listed for power limited operation of outputs and comply with NFPA 70 (NEC), article 760. The power supply shall support a full 8A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a "Dry contact" opening. The units shall be 8 ampere, 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 8 to 33 VDC or FWR. The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions. The power supply shall provide four Class "B", two Class "A", or two Class "B" and one Class "A" NAC circuit(s). Eight Class "B" or Four Class "A" circuits shall be available with an optional PS-EXP module. The PS-8 unit shall supply up to 240 mA of auxiliary power that is available during both non-alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non-alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at maximum rate of 0.750 Amps per hour. Input activation options shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class "B" applications or 3 amperes each for Class "A". The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The power supply shall provide independent loop supervision for either Class "A" or Class "B" FACP NAC circuits and shall have the capability to "steer" all alarm or trouble conditions to either incoming NAC circuit. The units shall have common trouble terminals. The power supply shall be powered from a 120 VAC source with a current consumption of xx amperes max. The unit shall incorporate short circuit protection with auto reset. The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure. The charger shall incorporate fused protection for the batteries and have the ability to report low battery and/or no battery condition(s). Standby current for battery back up shall be 0.129 Amps max. The power supply shall have the ability to latch trouble LED's so the circuit in trouble can be identified. The cabinet dimensions shall be 17" H x 15" W x 5.5" D. The power supply shall be Wheelock POWERPATHTM Series PS-6, or equivalent. The unit shall be stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC). The unit shall be UL 864 Listed for power limited operation of outputs and comply with NFPA 70 (NEC), article 760. The power supply shall support a full 6A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit (NAG) from any Fire Alarm Control Panel (FACP) or a "Dry contact" opening. The units shall be 6 ampere, 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 8 to 33 VDC or FWR. The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions. The power supply shall provide four Class "B", two Class "A", or two Class "B" and one Class "A" NAC circuit(s). Eight Class "B" or Four Class "A" circuits shall be available with an optional PS-EXP module. The PS-6 unit shall supply up to 200 mA of auxiliary power that is available during both non-alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non-alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at a maximum rate of 0.750 Amps per hour. Input activation options shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class "B" applications or 3 amperes each for Class "A". The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The power supply shall provide independent loop supervision for either Class "A" or Class "B" FACP NAC circuits and shall have the capability to "steer" all alarm or trouble conditions to either incoming NAG circuit. The units shall have common trouble terminals. The power supply shall be powered from a 120 VAC source with a current consumption of xx amperes max. The unit shall incorporate short circuit protection with auto reset. The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure. The charger shall incorporate fused protection for the batteries and have the ability to report low battery and/or no battery condition(s). Standby current for battery back up shall be 0.130 Amps max. The power supply shall have the ability to latch trouble LED's so the circuit in trouble can be identified. The cabinet dimensions shall be 17" H x 13" W x 3.5" D. WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLA- TION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accor- dance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 1 YEAR WARRANTY Made in USA S9100 PS-6 & 8 12/09 Cooper Notification is Wheelock 1MCJ SAFEPATH WAV J COOPER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0785:0167 Page 1 of 1 CATEGORY: 7315 -- POWER UNITS LISTEE: Cooper Wheelock lnc.273 Branchport Ave, Long Branch, NJ 07740 Contact: Lyn Sorrentino (732) 962-7832 Fax (732) 962-7856 Email: Iyn.sorrentino@cooperindustries.com DESIGN: Model POWERPATHTM PS-6, PS-6E, PS-8, PS-8E and *PSEXP Notification Appliance Circuit (NAC) Power Supply Units. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC for PS-6, PS-8 240 VAC for PS-6E, PS-8E INSTALLATION: Model POWERPATHTM PS-6, PS-6E, PS-8, PS-8E and *pSExp Notification Appliance Circuit (NAC) Power Supply Units. Refer to listee's data sheet for additional detailed product description and operational considerations. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units and notification appliances. Authority having jurisdiction should be consulted prior to installation. The unit can be programmed to generate the three-pulse temporal fire alarm evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 edition. 12-09-09 fm STI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division 1 EST Fire & Life Safety Security MIIi,iiiIiTIiTflu.riuIIPk.i Overview The SIGA-270 and SIGA-278 series Manual Pull Stations are part of GE Security's Signature Series system. The SIGA-270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape. They are made from die-cast zinc and finished with red epoxy pow- der-coat paint complemented by aluminum colored stripes and markings. With positive pull-lever operation, one pull on the station handle breaks the glass rod and turns in a positive alarm, ensuring protection plus fool-proof operation. Presignal models ISIGA-270P1 are equipped with a general alarm (GA) keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is not required for proper operation. GE Security's double action single stage SIGA-278 station is a contemporary style manual station made from durable red colored lexan. To initiate an alarm, first lift the upper door marked "LIFT THEN PULL HANDLE", then pull the alarm handle. Standard Features Note: Some features described here may not be supported by all control systems. Check your control ponel's /nstollotion and Operation Guide for detoils. Traditional familiar appearance SIGA-270 models feature our familiar teardrop design with simple positive pull action and sturdy die-cost metal body. One stage (GA), two stage (pre-signal), and double action models SlGA-270 models are available for one or two stage alarm sys- tems. The single stage double action SIGA-278 features a rugged Lexan housing with keyed reset mechanism. Break glass operation An up-front visible glass rod on the SIGA-270 discourages tam- pering. Intelligent device c/w integral microprocessor All decisions are made at the station allowing lower communica- tion speed while substantially improving control panel response time. Less sensitive to line noise and loop wiring properties; twisted or shielded wire is not required. Non-volatile memory Permanently stores serial number, type of device, and job num- ber. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each station transmits wiring information to the loop controller regarding its location with respect to other devices on the circuit. Electronic addressing Permanently stores programmable address; there are no switches or dials to set. Addresses are downloaded from a PC, or the SIGA-PRO Signature Program/Service Tool. Stand-alone operation The station inputs an alarm even if the loop controller's polling interrogation stops. Diagnostic LEDs Status LEDs; flashing GREEN shows normal palling; flashing RED shows alarm state. Designed for high ambient temperature operation Install in ambient temperatures up to 120°F (49 °Cl. Manual Pull StatiOns H I r"- MEA - I j Patented SIGA-278 SlGA-270 SERIES Data Sheet 85001-0279 Issue 7 Not to be used for installation purposes. Page 1 of 4 Application The operating characteristics of the fire alarm stations are deter- mined by their sub-type code or "Personality Code". NORMALLY- OPEN ALARM - LATCHING (Pesonality Code 1) is assigned by the factory; no user configuration is required. The device is configured for Class B IDC operation. An ALARM signal is sent to the loop con- troller when the station's pull lever is operated. The alarm condition is latched at the station. Compatibility Signature Series manual stations are compatible only with GE Secu- rity's Signature Loop Controller. Warnings & Cautions This device will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance To test or reset) the station simply open the station and operate the exposed switch. The SlGA-270 series are opened with a tool; the SIGA-278 requires the key which is supplied with that station. The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Au- thority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Typical Wiring The fire alarm station's terminal black accepts #18 AWG (0.75mm2) to #12 AWG (2.5mm2) wire sizes. See Signature Loop Controller cata- log sheet for detailed wiring requirement specifications. Wiring Notes Al Refer to Signature Loop Controller manual for maximum wire distance. 2. All wiring is power limited and supervised. REAR VIEW — of SIGA-278 0 TG Ted LED Green LED (Aja rrr/Acllv ) (Normal) 0 TB TI- DATA IN( ) DATA OUT 'I DATA IN(.) > DATA OUT From Signature Controller Y to Next Device or Previous Device A Figure 4. Single Stage Systems REAR VIEW of SIGA-270P, SIGC-270P5 Red LED Green LED (Alarrn/Aolive) (Normal) I DAtA IN (-x) > 1 DATA IN(-) > From Signature Controller or Previous Device DATA 01111.) DAtA OUt() To Next Device Figure 5. Two Stage Systems Data Sheet 85001-0279 Issue 7 Not to be used for installation purposes. Page 2 of 4 Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 2112 inch 164 mm) deep 1-gong boxes Two stage presignal l270Pl models require 1112 inch (38 mm) deep 4-inch square boxes with 1-gang, ½-inch raised covers. Openings must be angular. Rounded openings are not acceptable. Recommended box: Steel City Model 52-C-13; in Canada, use Iberville Model Cl-52-C-49-1/2. All models include terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm') wire size. GE Security recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system commission- ing. Setting complicated switches or dials is not required. Each station has its own unique serial number stared in its on-board memory. The loop controller identifies each device on the loop and assigns a 'soft address to each serial number. If desired, the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Latch Compatible Electrical Box Compatible Electrical Box Cover Release I - Cover Release ..s. Screw Back Back Plate Plate Toggle Toggle ' I L\ Switch Glass Rod Glass Rod ------- 4 Release Lever OPEN LJr6J °. Figure 1. SIGA-278 installation Figure 2. SIGA-270, SlGC-270F, SIGC-2708 installation Cover Release Scrtw ___ Compatible Electrical Box \ {' with /rnch raised covers--+ Plate o Toggle ' e Sr c_3,5__..j:;" ,G Glass Rod Release Lever Do not use boxes with rounded Figure 3. SIGA-270P, SIGC-270PB installation Data Sheet 85001-0279 Issue 7 Not to be used for installation purposes. Page 3 of 4 Specifications 1888-378-2329 F 866-503-3996 SIGA-270, SIGC-270F, SlGA270P, Canada Catalog Number SlGC-2708 SIGC-270P8 S)GA278 1 519 376 2430 Description Single Action Single Action -Two uble F 519 376 7258 - One Stage Stage (Presignal) - One Stage Asia Addressing Uses 1 Module Uses 2 Module i Uses 1 Module T 852 2907 8108 Requirements Address Addresses Address F 852 2142 5063 . Standby = 2501.iA Standby = 396pA Standby = 250pA Operating Current Activated = 4001JA Activated = 680pA Activated = 400pA Australia 1 61 39259 4700 Construction & Finish Diecast Zinc - Red Epoxy Lexan - Red with F 613 9259 4799 with aluminum markings white markings Type Code Factory Set Europe - . 1322 725 1120 Operating Voltage 15.2 to 19.95 Vdc 119 Vdc nominal) F 32 272186 13 Storage and Operating Operating Temperature: 32°F to 120°F 10°C to 49°Cl Environment Storage Temperature: -4°F to 140°F 1-20°C to 60°Cl Humidity: 0 to 93% RH Latin America -_- .............. . ........................ ........ ............................... .............................. -... . ............................ ... 1305 593 4301 On-board Green LEO - Flashes when polled F 305 593 4300 LED Operation On-board Red LED - Flashes when in alarm Both LEDs - Glow steady when in alarm (stand-alone) www uri .gesocty.com Compatibility Use With: Signature Loop Controller 02006 General Electric Company Agency Listings UL, ULC note 1), MEA, CSFM All Rights Reserved Note: S!GC270F, SIGC••2706 and SIGC-270PB are ULC listed only. Suffix 'P' indicates French markings. Suffix "B' indicates English/French biling ual markings. Signature Series is a Trademark of GE Security, Ordering Information Catoog ' Ship WE. Number Description lbs (kg) SIGA-270 One Stage Fire Alarm Station, English Markings - UL/ULC Listed SIGC-270F One Stage Fire Alarm Station, French Markings - ULC Listed SIGC-270B One Stage Fire Alarm Station, French/English Markings - ULC Listed SIGA-270P Two Stage lPresignaU Fire Alarm Station, English Morkings - UL/ULC 11051 SIGC-270PB Two Stage (Presignol) Fire Alarm Station, French/English Markings - ULC Listed 51GA278 Double Action (One Stage) Fire Alarm Station, English Markings - UL/ULC Listed Accessories 32997 GA Key w/Tag - for pre-signal station (CANADA ONLY) 276-K2 GA Key - for pre-signal station IUSA ONLY) 27165 12 Glass Rods - for SIGA-270 series (CANADA ONLY) 0.1(.05) 270-GLR 20 Glass Rods - for SIGA-270 series (USA ONLY) 276-GLR 20 Glass Rods - for SIGA-278 series 276B-RSB Surface Mount Box, Red - for SIGA pull stations 110.61 l " imagination at work Data Sheet 85001-0279 Issue 7 Not to be used for installation purposes. Page 4 of 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM b LISTING SERVICE LISTING No. 7150-1657:0129 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Brandenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 Fax (941) 309-8123 Email: rhonda.micocheroge.com DESIGN: Models SIGA-270, SlGA-270P, and SIGA-278 noncoded, intelligent manual pull stations*. Unit consists of a listed pull station and a remote transponder. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. NOTE: Formerly 7150-1591:129 and 7150-1388:194 7-29-10 ma , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed '\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division EWJ Intelligent initiating Devices The Signature Series Model SlGA-PS Intelligent Photoelectric Smoke Detector gathers analog information from its smoke sensing ele- ment and converts it into digital signals. The detectors on-board microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually eliminated. The microprocessor in each detector provides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detec- tor constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in the detectors non-volatile memory Automatic Device Mapping - The loop controller learns where each devices serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each devices installed location to prevent a detector from being rein- stalled (after cleaning etc.) in a different location from where it was originally. Stand-alone Operation - A decentralized alarm decision by the detector is guaranteed. On-board intelligence permits the detector to operate in stand-alone mode. If loop controller CPU communica- tions fail for more than four seconds, all devices on that circuit go into stand-alone mode. The circuit acts like ô conventional alarm receiving circuit. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Standard Features Integral microprocessor Non-volatile memory Automatic mapping device Electronic addressing Environmental compensation Intelligent detector Wide 0.67% to 3.77%/ft. sensitivity range Twenty pre-alarm sensitivity values, set in 5% increments Identification of dirty or defective detectors Automatic day/night sensitivity adjustment Twin RED/GREEN status LEDs Standard, relay, fault isolator, and audible mounting bases Designed and manufactured to ISO 9001 standards n t E? '1Y'-m e n t Smoke Detector SIGAPS Avoilable Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 1 of 4 I nstall ation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square electrical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. J 0.13' (20 mm) J 2.0"(51 mm) 4.4' (112 mm) Tamper-Pest Lever Arm Break off to, b o (Located on Base) Access Slot for Tamper-Resist Mechanism 7_,D~Z Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report can be printed to satisfy NFPA sensitivity measure- ments which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper detector operation should be planned to meet the requirements of the Au- thority Having Jurisdiction (AHJI. Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Compatibility The SlGA-PS detectors are compatible only with the Signature Loop Controller. Warnings & Cautions This detector will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. This detector will NOT sense fires that start in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector to alarm it Accessories All detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 1112 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SlGA-SB4, SIGA-RB4, and SIGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SIGA-TS4 Trim Skirt which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4" sqare box only. C I SRA-AB4G ;B, S8 Si(,A-18 SIGA-RB SIGA-LED Audible Base Isolator Base Relay Base Remote LED Standard Base SI-SB4 - This is the basic mounting base for GE Security Signature Series detectors. The SIGA-LED Remote LED is supported by the Standard Base. Relay Base SIGA-RB, SIGA-R84 - This base includes a relay. Nor- mally open or closed operation is selected during installation. The dry contact is rated for lamp (pilot duty) © 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA- RB can be operated as a control relay if programmed to do so at the control panel (E5T3 V.2 only). The relay base does not support the SIGA-LED Remote LED. Audible Base SlGA-AB4G - This base is designed for use where localized or group alarm signaling is required. When the detector senses an alarm condition, the audible base emits a local alarm signal. The optional SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the some 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized - when the detector enters the alarm state, the relay is energized. Isolator Base SIGA-113, SIGA-184 - This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - when the isolator next to the short closes, reopens within 10 msec. The process repeats beginning on the other side of the loop con- troller. Remote LED SIGA-LED - The remote LED connects to the SlGA-SB or SIGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 2 of 4 Audible Detector Base, SIGA-AB4G S oc ® Volume setting l. Tone setting Default = High volume Default = Temporal pattern Cut for low volume Cut for steady tone ltD CT j o - To conttura output volume orrone. cut the circuit board as shom. 24 Vdc in II I - 24 Vdc out From power supply or * p '° To next base or EOL relay previous base [I 1 Data in - Data out From Signature controller or To next Signature device previous device DATA IN(-) I \ I1 r9 I DATA OUT (-) DATA IN (+) DATA OUT (+) From Signature Controller To Next Device or Previous Device Normally- Normally- DAT DA1, o, From Signature Controller or Previous Device Term Description 1 Normally Open 2 DATA IN/OUT 1+) 3 common 4 DATAINI - l 5 Not Used 6 Normally-closed 7 DATA OUT I-I CONTACT RATING 1.0 Amp @30 voc OUT (-) (Pilot Duty) DiJT(+) To Next Device Isolator Detector Base, SIGA-113, SIGA-I134 DATA IN (+) From Signature Controller or Previous Device DATA OUT (+) To Next Device Remote LED (SiGA-LED) Max. Resistance per Wire Must NOT Exceed lOt) Term Description 1 Not Used 2 oATAiN/ourl+l 3 Not used 4 DATA INI-1 5 Remote LEO I-I 6 Remote LEO (+1 7 Not used 8 DATA OUT I-I Term Description 1 Not used 2 DATA IN/OUT (+1 3 DATAINI - l 4 Not Used 5 Not Used 6 DATA OUT I-I 7 Not Used OUT(-) DAI Application Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow, smoldering fires. The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single sensing element is suited for all test fires. GE Security recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. SIGA-HRSandSIGA HFS Rate-of-Rise/ S'GA PF-S SIGA IPHS Test Fire SIGA IS on SIGA PS Photo Fixed Temp Photo Heat D on/Photo/Heat 40 Open Wood optimum unsuitable optimum very suitable optimum Wood Pyrolysis suitable optimum unsuitable optimum optimum Smouldering Cotton very suitable optimum unsuitable optimum optimum Poly Urethane Foam very suitable very suitable suitable very suitable optimum n-Heptane optimum very suitable very suitable optimum optimum Liquid Fire without Smoke unsuitable unsuitable optimum very suitable very suitable Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base, SlGAS8, SlGAS84 Relay Detector Base, SIGARB, SIGA-R84 Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 3 of 4 U.S. fl cations T 888-378-2329 F 866-503-3996 Sensing Element Photoelectric - Light Scattering Principle Canada Storage & Operating Air Velocity Range: 0 to 5,000 ft/mm 10 to 25.39 m/s); Humidity: 0 to 93% T 519 376 2430 Environment RH, Non-condensing Operating Temp: 32°F to 120°F 10°C to 490Cl; Star- F 519 376 7258 age Temp: -4°F to 140°F l-20°Cto 60°Cl Asia Sensitivity U li/U-LC-0.67%to3-77%obsc-ration/foot 1852 2907 8108 User Selected Alarm Most Sensitive: 1.0%/ft.; More Sensitive: 2.0%/ft.: Normal: 2.5%/ft.; Less F 852 2142 5063 Sensitivity Settings Sensitive: 3.0%/ft.: Least Sensitive: 3.5%/ft. Pre-alarm Sensitivity 5% increments, allowing up to 20 pre-alarm settings - Australia T 613 9259 4700 Operating Voltage :.2to .9.95Vdc .19 Vdc nominal) F 61 392594799 Operating Current Quiescent: 451JA © 19 V; Alarm: 45pA © 19 V Emergency Stand-alone Alarm Mode: 18mA Pulse current: 100 A 1100 msecl; During Communi- cation: 9 mA max. 13227251120 F 3227218613 Construction & Finish High Impact Engineering Polymer - White Compatible Mounting SIGA-SB Standard Base, SIGA-RB Relay Base, SIGA-IB Isolator Base, SIGA- Latin America Bases AB4, S1GA-AB4G Audible Bases 1305 593 4301 LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes F 305 593 4300 when in alarm Bath LEDs - Glow steady when in alarm (stand-alone) www.gesecurity.com Compatible Remote Red LED (model SIGA-LED) Flashes when in alarm Compatibility Use With: SIGNATURE Loop controller © 2006 General Electric Company Address Requirements Uses one Device Address All Rights Reserved ...... .................. ....... .............. ...... ................. ..................... ........ ...........................-.. .................................................... Agency Listin1 111-1111".gs UL, ULC, MEA, CSFM UL Listed Spacing 30 ft Signature Series is a Trademark of GE Security. Ordering Information ( Di c r p 1 50:o 1 II I ibs P) 5100-PS Intelligent Photoelectric Detector - UL/ULC Listed 0.5 (.23) Accessories SlGA-SB Detector Mounting Base - Standard SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS4 Trim Skirt SIGA-RB Detector Mounting Base w/Relay .LGA-RB44-inch Detector Mounting Base w/Relay, c/w SlGA-TS4 Trim Skirt 0.2 1.091 SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-1B4 4-inch Detector Mounting Base w/ Fault Isolator, c/w SIGA-TS4 Trim Skirt SIGA-LED Remote Alarm LED - SlGA-AB4G Audible (Sounder) Base .3(0.15) SIGA-TS4 Trim Skirt (supplied with 4-inch bases) .11.041 II1iIi[iIEitSL4I.]iILIW.]i! Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 4 of 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1657:0126 Page 1 of 1 CATEGORY: 7272 -- PHOTOELECTRIC SMOKE DETECTOR LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Brandenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 Fax (941) 309-8123 Email: rhonda.micocheroge.com DESIGN: Models SIGA-PS and SIGA-PHS photoelectric smoke detectors. Model SIGA-PHS employs an integral 135°F fixed temperature heat sensor. This heat sensor is a supplementary device to the smoke detector and is not approved as a required heat detector. Refer to listee's printed data sheet for additional detailed product description, installation and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's listed fire alarm control units and Model SIGA Series bases (CSFM Listing No. 7300-1657:120). Model SIGA-PS may be suitable for installation directly in the duct with the velocity range from 0-5000 feet/mm. NOTE: Model SIGA-PHS is not intended for use in lieu of a required heat detector. Formerly 7272-1591:126 and 7272-1388:186 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division GE EST Fire & Life Safety Security Intelligent Input/Output Overview The SIGA-CT1 Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits llDCl. The actual function of these modules is determined by the "personality code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configuration. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The SlGA-CT1 and SIGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module. The SlGA-MCT2 is part of the UlO family of plug-in Signature Series modules. It functions identically to the SIGA-CT2, but takes advan- tage of the modular flexibility and easy installation that character- izes all UlO modules. Two- and six-module UIO motherboards are available. All wiring connections are made to terminal blocks on the motherboard. UlO assemblies may be mounted in GE Security enclosures. Standard Features Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the module through the loop controller. Plug-in (Ub) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. Automatic device mopping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop control- ler, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. Non-volatile memory Permanently stores serial number, type of device, and job number. o Stand-alone operation The module makes decisions and inputs an alarm from initiating devices connected to it even if the loop controller's polling interro- gation stops. (Function availability dependent upon control panel.) Ground fault detection by address Detects ground faults right down to the device level. Input Modules SIGA-M, SIGA-CT2 & SIGA-MCT2 I .. SIGA-MCT2 'ij' Data Sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 1of 4 MEA AppIictor Ncts A,,IbIe Signature Series Overview The Signature Series intelligent analog-addressable system from GE Security is an entire family of multi-sensor detectors and mount- ing bases, multiple-function input and output modules, network and non-network control panels, and user-friendly maintenance and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device provides four addi- tional benefits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This informa- tion is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/Service Tool. Automatic Device Mapping -The Signature Data Controller (SDC) learns where each device's serial number address is installed rela- tive to other devices on the circuit. The SDC keeps a map of all Sig- nature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. Installation SIGA-CT1 and SIGA-CT2: modules mount to North American 2112 inch(64 mm) deep 1-gong boxes and 1112 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm') wire size. SIGA-MCT2: mount the UIO motherboard inside a suitable GE Secu- rity enclosure with screws and washers provided. Plug the SIGA- MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlO motherboard terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm') wire size. UIO Motherboard - 6-32 Self-tapping - screws ---------- j Plug i 1110) C,iptive I M' .' screws - -fl-- I 7 ..-1----------____ #6 Rat washers —cabinet or electrical enclosure Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. GE Security recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SIGA-CT1. Two person- ality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - As- sign to one or bath circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Personality Code 2)- Assign to one or bath circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiating devices such as Waterfiow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3)- Assign to one or bath circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4)- Assign to one or bath circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condi- tion is latched at the module. Data Sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 2 of 4 Typical NO, Initiating Device A A A Style B (Class B) 30 UL/IJLC Listed 471<0 EOL Typical N.C. Initiating Device INPUT 1 uL/uLC Listed 471<0 EOL INPUT 2 UL/ULC Listed 471<1<5 EOL Red LED (Alarm/Aclive) TEl 1 From Signature Controller or Previous Device A SlGA-CT2 UL'tJLC L5tOd d7Krr EDt. Typicat NO lttt)allttp Orator i I ree0 LED (Normal) ULIULC Lierd 4742) EOL I 23 4 ,/ ,.- srea4JroIRl sedo, motherboard JILL i721 TO Ot ,r,oduleemayrothor - Crr LED R~d LED ,orma5 2' L__J/ NlNocorre4,000i4m2eroothrgo 1,equi,ed for S)cAa4cn2, SIGA-MCT2 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0,75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specification Maximum Allowable Wire Resistance 50 ohms (5 ohms per wire) per Circuit Maximum Allowable Wire Capacitance O.1pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (0.75 mm') #16 AWG 4,000ft(1,219m) #14 AWG (1.50 mm') #12 AWG (1.50 mm') Red LED IL Green LED (Alarm/Active) I— (Normal) TB _. f DATA IN 0 DATA OUT (+) DATA IN > DATA OUT(-) I From Signature Controller To Next Device or Previous Device SlGA-CT1 NOTES Maximum 25 Ohm resistance per wire. Maximum #12 AWG 12.5 mm2 I wire; Minimum #18 AWG (0.75 mm?). Refer to Signature controller installation sheet for wiring specifications. Maximum 10 Vdc @350 pA The SIGA-U106R and the SIGA-U102R do not came with T814. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not Operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialis:. Compatibility The Signature Series modules are compatible only with GE Securi- ty's Signature Loop Controller. Data Sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 30f4 Security J. T8 8-378-2329 Specifications F 866. 503.. 3996 N r Go T it r IGO lit 12 Canada T519 376 2430 Description Single Input Module Dual Input Module F 519 376 7258 Type Code 48 (factory set) Four 49 (factory set) Four sub-types (personality sub-types (personality codes) are available Asia codes) are available F 852 2142 5063 Address Requirements .US du ..... Two Module Addresses dress Australia Operating Current Standby = 250pA; Standby = 396pA; Activated = 680pA 1613 9259 4700 Activated = 400pA F 613 9259 4799 Operating Voltage .152 to 19.95 Vdc 119Vd.nominal) Europe Construction High Impact Engineering Polymer Mother- 322 72186 13 Mounting .North American 211 inch .64 deep one-gang ..102R/6R/6 boxes and 1112 inch (38 mm) deep 4 inch square board Latin America boxes with one-gong covers and SIGA-MP 1305 593 4301 mounting plates F 305 593 4300 Storage and Operating Operating Temperature: 32°F to 120°F I0°Cto49°Cl Storage Temperature: www.gesecurity.com Environment .........-4°Fto .t9°F -20°C ...9•C); Hum......9 ...RH LED Operation On-board Green LED - Flashes when polled: On-board Red LED - Flashes © 2006 General Electric company when in alarm/active Both LEDs - Glow steady when in alarm (stand-alone) All Rights Removed Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM Signature Series is a Trademark of GE Security. Ordering Information 011 c Q1 :A cci iption unL. j SIGA-CT1 Single Input Module - UL/ULC Listed 0.4)0.15) SIGA-CT2 Dual Input Module - UL/ULC Listed 0.4(0.15) SIGA-MCT2 Dual Input Plug-in 10101 Module - UL, ULC Listed 0.1(0.05) ot ½ ,c Louiwnwit 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0(0.6) SIGA-UI02R Universal Input-Output Module Board w/Riser Inputs 0.32 (0.15) - Two Module Positions SIGA-UIO6R Universal Input-Output Module Board w/Riser Inputs 0.62 (0.28) - Six Module Positions SIGA-UI06 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) MFC-A Multifunction Fire Cabinet - Red, supports Signature Module 7.0)3.1) Mounting Plates SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) imagination at work Data Sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 4 of 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:0121 Page 1 of 1 CATEGORY: 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Brandenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 Fax (941) 309-8123 Email: rhonda.micochero@ge.com DESIGN: Models SIGA-CC1, SIGA-CC2, SIGA-CT1, SIGA-CT2, SIGA-CR, SIGA-CRR, SIGA-UM, SIGA-MM1, SIGA-WTM, SIGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, SIGA-MCC1, SIGA-MCC2, SIGA-MCR and SIGA-MCRR remote transponders. Models SlGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SIGA-MB4, SlGA-MP1, SIGA-MP2 and SIGA-MP2L mounting plates. Models SIGA-UIO2R, SIGA-U106 and SIGA-U106R motherboards. Model CS-SIGA-CC1 P releasing module. Models SIGA-CC1 S and SIGA-MCC1 S Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SIGA-CR2 Control Relay Module. *Model SIGA-CT1HT; Signature Series High Temperature Single Input Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2- 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 7-29-10 ma TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an / endorsement or recommendation of the item listed. This listing should not be used to verify correct operational Z' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division COOPER Notification Series MIZ Mini Horn Appliances Description: Wheelock Series MIZ piezoelectric Mini Horns are compact electronic alarm appliances that are listed under UL Standard 464 for Audible Appliances in Public Mode Fire Protection Systems. The Series MIZ-24S models provide a field selectable Continuous or Code 3 horn tone when connected directly to a fire alarm control panel. They can also provide a synchronized code 3 horn tone using the Wheelock SM, DSM Sync Modules or PS-24-81VIC power supply. The series MIZ appliances are attractive, offer high sound output along with low current draw and are ideal for alarm signaling in individual rooms, apartments, hotels, motels and offices. Color choices of red or off-white will blend with any decor. Wiring Diagrams (for all models) FROMU 7F_ TO NEXT[] APPLIANCEC +F1 El OR EOLRO PRECEDING[] _APPLIANCED OR FACPLI Features: Approvals include: UL Standard 464, California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM), and Chicago (BFP) Field selectable settings for Temporal (Code 3) or Continu ous Horn Synchronized code 3 horn when used with Wheelock Sync Module Designed to meet or exceed NFPNANSI standards Convenient mounting to any standard single-gang box Beauty plugs to cover mounting screws No additional trimplate required for flush mounting Fast installation with In/Out screw terminals using #12 to #18 AWG High sound output with low current draw Available in red or off-white color Applications: Individual Rooms Apartments Hotels Motels Offices Specifications and Ordering Information Model Order Code Description Mounting Options** Agency Approvals UL MEA CSFM FM I BFP MIZ-245-R 8485 24 Volt, Red B X X X X * MIZ-245-W 8484 24 Volt, White B X X X X * *PENDING Refer to Data Sheet S7000 for Mounting Options. MEA APPROVED S5391 151-92-0 7125-0785:161 General Notes: Mini Horn models are Listed for indoor use with a temperature range of 32° F to 1200 F (0° C to 49° C) and maximum humidity of 93% RH ±2%. Rated Input voltage (either filtered DC or unfiltered full-wave-rectified FWR): 16-33 VOC (for 24 VDC MIZ-24S models) rcnirecrs ana The notification appliance shall be a Wheelock MIZ-24S audible appliance or approved equal. The Notification Appliance shall be electronic and shall have field selectable settings for Temporal (Code 3) or continuous horn and support coded systems operation. The anechoic sound pressure measurement on Temporal (Code 3) setting shall be 87 dBA minimum at 24VDC. The anechoic sound pressure measurement on Continuous Horn setting shall be 87 dBA minimum at 24 VDC. Operating voltages shall be 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provision for standard reverse polarity type supervision and IN/OUT wiring using terminals that accept #12 to #18 AWG wiring. The appliances shall be mounted indoors and mount on standard single-gang electrical backboxes requiring no additional trimplates or adapters. Table 1: UL Listed Models and Ranges Reverberant dBA Anechoic dBA Regulated Average PerUL46410ft c10ft Model UL RMS Mounting Voltage Current* Continuous Code 3 Continuous Code 3 Options (AMPS) dBA dBA dBA dBA 24 VDC 0.025 83.2 78.8 87.9 87.9 B MIZ-24S UL max* 0.026 85.8 81.3 90.6 89.7 B * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. àWARNlNG: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLIçATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P84408) AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALLAPPLIANCES ON THOSE CIRCUITS. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED VOLTAGE RANGE. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. NEAM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY D S1700 MIZ 02/08 Cooper Notification Is Wheelock (MEDGJ SAFEPATH WAV COOPER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0161 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.273 Branchport Ave, Long Branch, NJ 07740 Contact: Lyn Sorrentino (732) 962-7832 Fax (732) 962-7856 Email: Iyn.sorrentino@cooperindustries.com DESIGN: Models H54-24MCW, *Hs424MCwH *Hs424MCC *HS424MCCH HS4-241575W, HS4-24150W, HS4-241 77W, HS4-24185W, HS4-241 50C, and HS4-241 77C horn/strobe signal appliance for fire alarm service with signaling for the hearing impaired. Units are four-wire devices allowing separate energization of the audible and visual signals. Model HS-24 horn without signaling for the hearing impaired. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with "W' are intended for wall mount only; models with C" are intended for ceiling mount only. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. Model HS-24 horn is not suitable for hearing impaired applications. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division COOPER Notification Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories Description: Designed for life safety, performance and reliability, Cooper Wheelock's cost effective weatherpoof notification appliances include: Weatherproof Appliances Series Strobes RSSWP Horn Strobes ASWP Horns AH-24WP, AH-12WP Multitone Horn Strobes MTWP Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —31°F to 150°F (-40°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Cooper-Wheelock provides the industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (lOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA* and WFPA* kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. All models may be synchronized using the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones. Features: Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP). See agency approvals by model number on page two of this document Compliance with the following requirements: NFPA, UFC, ANSI 117. 1, OSHA Part 29, 1910.165, ADA Weatherproof with extended temperature range of —40°F to 150°F (-40°C to 66C)* Dual Listed strobe models (UL 1638 and UL 1971) Industry's highest strobe candela options Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Models with field selectable tone, dBA and candela settings Wall or ceiling mounting options Surface of semi-flush mounting IN/OUT wiring termination accepting two #12-18AWG wires at each terminal *The series RSSWP, ASWP, MTWP and ET70WP have UL approval down to -40°F. The AH-24WP, MT-12124 and the ET-101O have been ULC tested and approved to -40°F, but not submitted to UL. The AH-12WP has ULIULC approval to -31°F. 0 <*> MEA APPROVED * Patent Pending E5946 151-92-E 7125-0785:131 (ASWP) S5391 7125-0785:146 (ET70WP) S2652 7125-0785:156 (MTWP) 7300.0785:154 (RSSWP) NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount ITTI - H RSSWP MTVJP TT- L.-/ ASWP ET70Wp' - Strobe Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475W-FW White 3034 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCWH-FW White 5165 Audible Strobe ASWP-2475W-FR Red 9012 ASWP-24MCWH-FR Red 5137 ASWP-24MCWH-FW White 5140 Multi-tone Strobe MTWP-2475W-FR Red 8420 MTWP-2475W-FW White 3112 MTWP-24MCWH-FR Red 5132 MTWP-24MCWH-FW White 5134 Speaker Strobe ET70WP-2475W-FR Red 9077 ET70WP-2475W-FW White 3179 ET70WP-24185W-FR Red 4885 ET70WP-24185W-FW White 4891 ET70-24135W-FR Red 4872 ET70WP-24135W-FW White 4875 Ceiling Mount RSSWP M1fr ASWP ET70WP Strobe Order Code RSSWP-2475C-FR Red 4338 RSSWP-2475C-FW White 4446 RSSWP-24MCCH-FR Red 5167 RSSWP-24MCCH-FWWhite 5187 Audible Strobe ASWP-2475C-FR Red 4251 ASWP-2475C-FW White 4502 ASWP-24MCCH-FR Red 5149 ASWP-24MCCH-FW White 5157 Multi-tone Strobe MTWP-2475C-FR Red 4457 MTWP-2475C-FW White 4478 MTWP-24MCCH-FR Red 5102 MTWP-24MCCH-FW White 5122 Speaker Strobe ET70WP-2475C-FR Red 4452 ET70WP-2475C-FW White 4454 ET70WP-24177C-FR Red 4845 ET70WP-24177C-FW White 4859 ET70WP-24115C-FR Red 4550 ET70WP-24115C-FW White 4732 Audible Order Code AH-24WP-R Red 7416 AH-12WP-R Red 7415 Horn MT-1 2/24-R Red 5023 Speaker ET-1010-R Red 3135 ET-1010-W White 3137 UL Max. Current AH 24 VDC 12 VDC High (99) dBA 0.080 0.192 Med (95) dBA 0.043 0.108 Low (90) dBA 0.021 0.058 UL Reverberant dBA @ 10 Feet Wafts 1/8 1/4 1/2 1 2 4 8 ET-1010 77 80 83 86 87 92 94 ET70WP 78 81 84 87 190 93 95 Candela Ratings Series UL1971 UL1638 @ 77°F UL1638 @ -40°F RSS, ET70WP and MTWP UL Max Current (Strobe Only) ASWP High Med Low 2475 30** 180 115 0.138 0.168 0.155 0.150 MCWH 135 135 56 0.300 0.355 0.340 0.335 185 185 77 0.420 0.480 0.465 0.460 MCCH 115 115 47 0.300 0.355 0.340 0.335 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 **Wall mount rating only 24177 177 177 73 0.420 UL Max. Current (Audible) MTWP/MT 24 VDC MT 12 VDC IBA HI STD H STD Horn 0.108 0.044 0.177 0.034 Bell 0.053 0.024 0.095 0.020 March Time 0.104 0.038 0.142 0.034 Code 3 Horn 0.091 0.035 0.142 0.034 Code 3 Tone 0.075 0.035 0.105 0.021 Slow Whoop 0.098 0.037 0.142 0.035 Siren 0.104 0.036 0.152 0.030 Hi/Lo 10.057 0.025 0114 0.026 Model Number Agency Approvals Strobe UL MEA CSFM FM BFP RSSWP-2475 X X X X * RSSWP-24MCWH X * X * RSSWP-24MCCH X * X * * Audible Strobe ASWP-2475 X X X X X ASWP-MCWH X * X * * ASWP-MCCH X ° X * * Multitone Strobe MTWP-2475 X X X X MTWP-MCWH X * X * * MTWP-MCCH X * X * HornslAudibles AH-24WP X X X - X AH-12WP X X X - X MT-12/24 X X X X X Speaker Strobe ET70WP-2475 X X X ° * ET7OWP-185 X * X * ET70WP-177 X * X * * ET70WP-115 X * X * ET70WP-135 X * X * * *Pending Mounting Accessories - lOB WPSBB WPBB WBB Gasket Kit Order Code WP-KIT 4486 Flush Plates WFPA-R Red 4698 WFPA-W White 4701 WFP-R Red 4696 WFP-W White 4697 Backboxes IOB-R Red 5046 IOB-W White 5047 WPSBB-R Red 9751 WPSBB-W White 3033 WPBB-R Red 9014 WPBB-W White 4692 VVBB-R Red 2959 WBB-W White 2960 Mounting Options: Backboxes, Plates, Gasket Kits Surface Mount Flush Mount Exposed Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB + WP-KIT WFP ET70WP Speaker Strobes lOB lOB + WP-KIT WFP ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA AHWP HOrns WBB - WFP ET-1 010 Speakers WBB - WFP MTWP Multitone Horn Strobes lOB lOB + WP-KIT WFP Multitone Horn lOB lOB + WP-KIT WFP Wiring Diagrams SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. LJLJLJ TO NEXTO ECEDINGU I I REDO I APPL lANCED I PLIANCED - BLACRO E Ii 1 —[]OR EOLRLI II II FACPE STROBED AUDIBLEEII SERIES RSSWP, ASWP, AHWP, MTWP AND MT-12124 APPLIANCES FROND TO NEXTLI PRECEDINGO APPLIANCEL APPLIANCE ORG ttTF - OR EOLRD FACP[1 SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP MTWPO 0 0 Stroc 0 o SyncO Circui El NoddeD NRC orLJ PowerD 0- PS-12/24-0 Audibl FACPL RC N2 Note: Strobe circuit requires constant voltage. SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED WI DSM MODULE SINGLE CLASS "A" NAC CIRCUIT D S MLII ST ROB ED NACO SYNCD CIRCUITO OUTO Ø+OUT 10 0+ IN 10 RSS 0 MINUS 1 0-0 __0__02JDIBLEI I :eI IN 20 RSS: 20 0MINUS ROBE0 NACO e'+ OUT 20 CI RCUI TO RETURNO Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. ARCHITECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1 010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET70WP. They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock lOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S9004 WP 11/09 Cooper Notification is Wheelock* (MEDCJ SAFEPATK WAAEPPS j 2J COOPER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0131 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.273 Branchport Ave, Long Branch, NJ 07740 Contact: Lyn Sorrentino (732) 962-7832 Fax (732) 962-7856 Email: lyn.sorrentino@cooperindustries.com DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -2411 OW audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -Ware for wall mount only. *Models AS-1 21575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and *ASwp2475C audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *ASWP24MCWH and *ASWP24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFWR *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \. the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Listing No. 7125-0785:0131 Page 2 of 2 Flash Rate: 60 flashes/minute Candela: 15:l5cd,1575:15/75cd,30:30cd,75:75cd,95:95cd,100:loocd,1 10:1 lOcd MCW: Selectable 15cd, 30cd, 75cd,110cd MCC: Selectable 15cd, 30cd,75cd,95cd MCWH: Selectable 135cd,185cd (65cd, 90cd at -40 C) MCCH: Selectable 115cd,177cd (50cd, 75cd at -40 C) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP-24MCWH, AS-24MCW and AS-24MCWF-I are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix -w or WH are for wall mount only. Models with suffix -C or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, *Aswp2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12124, SMX-12/24, DSM-12/24 or DSMX-12124 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed "\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division () Underwriters Laboratories Inc. ® Northbrook. IL San Jose, CA Melville, NY Applicant ID No: 257057-001 Service Center No I Expires: 31-MAR-2011 A not-for-profit organization dedicated to public safety and committed to quality service CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: ALISO VIEJO, CA Alarm Service Company: (257057-001) Service Center: (257057-001) ADVANCED PROTECTION INDUSTRIES INC, ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER OBA NATIONAL MONITORING CENTER SUITE 250 SUITE 250 26800 ALISO VIEJO PKV 26800 ALISO VIEJO PKY ALISO VIEJO CA 92656 ALISO VIEJO CA 92656 The Alarm Service Company is Listed in the following Certificate Service Categories: File -Vol No. CCN Listing Category BPI 0307 -1 CRZM Monitoring Stations, National Industrial Security S8126 -1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31-MAR-2011 *** "LOOK FOR THE UL ALARM SYSTEM TI Fl CATE" , 1l © 2008 UL Form CS-CC Engineering Manager 10/T0 39Vd SAS INI 30tJ.T10A M01 L01t'8609L 6t7:50 0t0/60/11 Check a License - Contractors State License Board Page 1 of 1 Department of Consumer Affairs Contractors State Li2iseBoard Contractor's License Detail - License # 779653 DISCLAIMER: A license status check provides information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. >> CSLB complaint disclosure is restricted by law (W .7.124M If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. '>> Per B&P 7071.17 only construction related civil judgments reported to the CSLB are disclosed. Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. ' Due to workload, there may be relevant information that has not yet been entered onto the Boards license database. License Number 779653 Extract Date: 11/2/2010 KITE ELECTRIC INCORPORATED 11 MARCONI SUITE B Business Information IRVINE, CA 92618 BusnessPhoneNumbe(949)380-7471 ,,, Entity: Issue Date 05/30/2000 Expire Date 05/31/2012 License Status This license is current and active. All information below should be reviewed. Additional Status: CLASS DESCRIPTION Classifications: C10 ELECTRICAL CONTRACTOR'S BOND This license filed Contractor's Bond number CLB2707913 in the amount of $12,500 with the bonding company PLATTE RIVER INSURANCE _COMPANY. Effective Date: 01/0112007 Contractors Bonding History Bonding: BOND OF QUALIFYING INDIVIDUAL 1. The Responsible Managing Officer (RMO) ADAMS TRACY SCOTT certified that he/she owns 10 percent or more of the voting stock/equity of the corporation. A bond of qualifying individual is not required. Effective Date: 05/30/2000 BQrsB.ond.ng..Hi.sto,ry, This license has workers compensation insurance with the STATE COMPENSATION INSURANCE FUND Policy Number:1949136 Workers' Compensation: Effective Date: 02/01/2010 Expire Date: 02/01/2011 W...çs,r.Comp ..n,$ationHIt.o. Personnel listed on this license (current or disassociated) are listed on other licenses. Conditions of Use I Privacy Policy Copyright © 2010 State of California https://www2.cslb.ca.gov/OnlineServices/CheckLicensell/LicenseDetail.aspx?LicNum7... 11/02/2010