Loading...
HomeMy WebLinkAbout2710 GATEWAY RD; ; AS130022; Permit8/17/22,10:15 AM AS130022 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2710 GATEWAY RD Permit Type: SPRINK Parcel No: 2132631200 Lot #: 0 Reference No.: PC #: Project Title: CONTINUITY PRODUCTS TI Permit No: AS130022 Status: APPROVED Applied 2/19/2013 Approved: 3/5/2013 Issued: 3/5/2013 Inspector: Owner: LJRLLC Applicant: TOTAL FIRE PROTECTION, INC STE. 244 1611-AS. MELROSE DR. VISTA, CA 760-525-4329 P 0 BOX 743 RANCHO SANTA FE CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 268 0 268 0 1/1 Tto firFecon in c. MATERIAL DATA SUBMITTAL Continuity Products 2710 Gateway Road Carlsbad, CA 92011 Page * Description Manufacturer 1-2 Pipe Allied Dyna-Thread Pipe 3-10 Fittings Tyco Ductile Iron Fittings 11-12 Mechanical Tee Tyco Fig 40-5 Strap Tee 13-19 ! Sprinkler Tyco TY-FRB Recessed Sprinkler 20 Hanger Afcon Fig. 300 Ring Hanger 21 Hanger Afcon Fig 655 All Thread Rod 22 Attachment Sammy Wood Vertical Mount 23-25 Attachment Hilli HDI Drop in Anchor FILE COPY Total Fire Protection, Inc. 1611 A S. Melrose Dr. *244 Vista, CA 92081 (760)525-4329 fax (877) 724-4329 C16-955387 tfpjohnc@gmail.com LE COPY DynawThread" Full Line Sch-40 Replacement Dyna Threada offers the life expectancy of Sch4O with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. (9 <~> 9 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). 1TItfl1t']ii NI'S Nominal I.D. WI. M. (H20 Filled) Pc Wt/Lift (21') WtILIIt (24') WVlJft (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 1051 1W 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 11/2, 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2.104 3.050 4.57 30 1921 2196 228'i 50 53.4 4.5 6.80 30 871 996 103 tqco/Flow control () died 16100 S. Lathrop• Harvey, IL 60426 11350 Norcom Rd. Philadelphia, PA 19154 TUBE& CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Customer Service: 1 (800) 882-5543 Fax 708-339-1806 S3-3 Stamp Here r 1 ! ii Submittal Data Sheet Dyna-Thread® Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch40 is specified. Specifications & Approvals Super 40/ S Dyna-Thread pipe is manufactured to meet: ASTM A 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". Specifications[]j NPS Nominal I.D. WI. WI. (H20 Riled) Pcs/ WI/Lilt (21') Wt1l.ift (241) WI/Lilt (25' In; mm In; mm Lbs/Fl; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 1¼' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1'/2' 1.639 2.290 3.22 44 2115 2418 2511 40 41.6 3,4 4.79 44 959 1097 114 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 American Tube and Pipe was acquired by Allied Tube and Conduit on February I, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured U9 L FM U LC with Exterior galvanized coating. BLT is manufactured with Black lacquer coating. Listed Approved Listed Project: Sprinkler Contractor Date: Engineer: Specification Reference: System Type: Locations: Comments: 2 S3 -4 S tqC0 /Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Pipe Fittings NPT Threaded, Ductile Iron General Description The TycoO Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Listed and FM Approved Maximum Working Pressure: Series 800 and California Fittings: 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17,2 bar) Page 1 of 10 Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI B1.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable JANUARY, 2008 Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was Informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- cress or implied. including warranties of merchantability and fitness for p carticular curcose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or detect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. registered trademark of E. I. du Pont de Nemours and Company or its affiliates. TFPI7IO Page 2oflO TFPI7I0 Nominal Pipe Figure 813 Size ANSI A Approx. Inches Inches Weight Part DN (mm) Lbs. Number (kg) 1/2 1.13 0.22 86780 DN15 (28,7) (0,09) 3/4 1.31 0.33 86781 DN20 (33.3) (0,15) 1 1.50 0.48 86280 0N25 (38,1) (0,21) 1-1/4 1.75 0.73 86281 0N32 (44,5) (0,33) 1-1/2 1.94 0.93 86282 0N40 (49,3) (0,42) 2 2.25 1.55 86283 DN50 (57,1) (0,70) 2-1/2 2.69 2.70 86782 0N65 (68,3) (1,22) S 13 FIGURE 811 FIGURE 813 900 ELBOW 450 ELBOW Figure 811 B Approx. A B Inches Weight Part Inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0,11) (22,4) (9,7) 0.75 0.40 86205 1.00 0.44 (19,0) (0,18) (25,4) (11,2) 0.81 0.64 86200 1.13 0.81 (20,6) (0129) (28,7) (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43) (33,3) (16,0) 1.19 1.24 86202 1.44 0.69 (302) (0,56) (36,6) (17,5) 1.50 1.74 86203 1.68 0.94 (38,1) (0,79) (42,7) (23,9) 1.56 3.28 86204 1.94 1.00 (39,6) (1,49) (49,3) (25,4) TABLE I NOMINAL DIMENSIONS FIGURES 811 & 813 TFPI7IO Page 3 of 10 TB—i FIGURE 812 900 REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C D Approx. Weight Part Inches Inches Inches Inches Inches Lbs. DN (mm) (mm) (mm) (mm) Number (kg) 3/4x1/2 1.19 1.19 0.63 0.63 0.33 86342 DN20 x 15 (30,2) (30,2) (16,0) (16,0) (0,15) 1 x1/2 1.25 1.38 0.56 0.81 0.44 86210 DN25 x 15 (31,8) (35,1) (14,2) (20,6) (0,20) 1 x3/4 1.38 1.44 0.69 0.88 0.53 86211 DN25 x 20 (35,1) (36,6) (17,5) (22,4) (0,24) 1-1/4 x 1/2 1.31 1.50 0.63 0.94 0.64 86212 0N32 x 15 (33,3) (38,1) (16,0) (23,9) (0,29) 1-114x314 1.44 1.63 0.75 1.06 0.75 86213 DN32 x 20 (36,6) (41,4) (19,0) (26,9) (0,34) 1-1/4x1 1.56 1.68 0.88 1.00 0.77 86214 DN32 x 25 (3,6) (42,7) (22,4 (25,4) (0,35) 1-1/2 x 3/4 1.50 1.75 0.75 1.19 0.95 86221 DN40 x 20 (38,1) (44,4) (19,0) (30,2) (0,43) 1-1/2 x 1 1.63 1.81 0.88 1.13 0.99 86215 DN40 x 25 (41,4) (46,0) (22,4) (28,7) (0,45) 1-112x1-114 1.31 1.88 1.13 1.19 1.14 86216 0N40 x 32 (46,0) (47,8) (28,7) (30,2) (0,52) 2 x 3/4 1.33 1.94 0.88 1.38 1.39 86217 DN50 x 20 (41,4) (49,3) (22,4) (35,1) (0,63) 2x1 1.75 2.06 2.00 1.31 1.58 86218 DN50x25 (44,4) (52,3) (50,8) (33,3) (0,72) 2 x 1-1/2 2.00 2.19 1.25 1.44 1.67 86220 DN50x40 (50,8) (5516) (31,8) (36,6) (0,76) 2-1/2 x 2 2.38 2.63 1.25 1.88 3.01 86262 DN65x50 (60,5) (66,8) (31,8) (47,8) 1 (1,36) TABLE 2 NOMINAL DIMENSIONS FIGURE 812 0 (D S S TFPI7I0 Page 5of 10 S T I_A7 FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING Figure 814 Figure 818 A B tM0c A B Inches Inches Weight Part Inches Inches (mm) (mm) Lbs. Number (mm) (mm) (kg) 1.13 0.56 0.33 86340 1.38 0.31 (28,7) (14,2) (0,15) (35,1) (7,9) 1.31 0.75 0.50 86341 1.63 056 (33,3) (19,0) (0,23) (41,4) (14,0) 1.50 0.81 0.85 86230 1.75 0.38 (38,1) (20,6) (0,38) (44,4) (9,7) 1.75 1.06 1.30 86231 2.00 0.56 (44,4) (26,9) (0,59) (50,8) (14,0) 1.94 1.19 1.63 86232 2.19 0.75 (493) (30,2) (0,74) (55,6) (19,0) 2.25 1.50 2.63 86233 2.63 1.13 (57,1) (38,1) (1119) (66,8) (28,7) 2.69 1.56 4.55 86234 3.00 0.75 (68,3) (39,6) (2,06) (76,2) (19,0) TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 Nominal Pipe Size Approx. ANSI Inches Weight Part ON Lbs. Number (kg) 1/2 0.18 72779 DM15 (0,08) 3/4 0.26 72778 DN20 (0111) 1 0.44 72755 DN25 (0,20) 1-1/4 0.54 72754 DM32 (0,24) 1-1/2 0.71 72753 DN40 (0,32) 2 1.15 72752 DM50 (0,52) 2-1/2 2.29 72758 DN65 (1,04) 41 TFP1710 Page 6of1O C S 0 Page 7 of 10 TFPI7IO S FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815 A B C D F F Approx. ANSI inches Inches Inches Inches Inches Inches Inches Weight Part DN (mm) (mm) (mm) (mm) (mm) (mm) Lbs. Numb er (kg) 1-1/2x1-114x112 1.44 1.31 1.69 0.69 0.63 1.13 1.03 DN40 x 32 x 15 (366) (33,3) (42,9) (17,5) (16,0) (28,7) (0.47) 86257 1-112x1-1/4x3/4 1.50 1.44 1.75 0.75 0.75 1.19 1.10 DN40 x 32 x 20 (38,1) (36,6) (44.5) (19,0) (19,0) (30,1) (0,50) 86258 1-1/2x1-1/4x1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 86259 DN40 x 32 x 25 (41,4) (39,7) (46,0) (22,4) (22,4) (28,7) (0,59) 1-1/2x1-114x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 86260 0N40 x 32 x 50 (55.6) (54,1) (50,8) (36,6) (36,6) (57,1) (0.88) 1-1/2x1-1/2x1/2 1,44 1.44 1.69 0.69 0.69 1.13 1.14 86261 DN40 x 40 x 15 (36.6) (36,6) (42,9) (17,5) (17,5) (28,7) (0,52) 1-112x1-112x3/4 1.50 1.50 1.75 0.75 0.75 1.19 1.23 86262 DN40x40x20 (38,1) (38,1) (44,4) (19,0) (19,0) (30,1) (0,56) 1-1/2x1-1/2x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 86263 DN40x40x25 (41,2) (41,2) (46,0) (22,4) (22,4) (28,7) (0,62) 1-1/2x1-1/2x1-114 1.81 1.81 1.88 1.06 1.06 1.19 1.50 DN40 x 40 x 32 (46,0) (46,0) (47,6) (27,0) (27,0) (30,1) (0,68) 86264 1-1/2x1-112x2 2.19 2.19 2.00 1.44 1.44 1.25 2.00 86265 DN40 x 40 x 50 (55,5) (55,5) (50.8) (36,6) (36,6) (31,7) 2 xl x 2 2.25 2.00 2.25 1.50 1.31 1.50 2.18 86266 DN50 x 25 x 50 (57.2) (50.8) (57.2) (38,1) (33,3) (38,1) (0,99) 2x1-114x2 2.25 2.13 2.25 1.50 1,44 1.50 2.31 86267 DN50x32x50 (57,2) (54,1) (57.2) (38,1) (36,6) (38,1) (1,05) 2x1-112x1/2 1.50 1.44 1.88 0.75 0.69 1.31 1.50 86268 DN50 x 40 x 15 (38,1) (36,6) (47.8) (19,0) (17,5) (33,3) (0,68) 2x1-112x314 1.63 1.50 1.94 0.88 0.75 1.38 1.61 86269 DN50 x 40 x 20 (41,4) (38,1) (49,3) (22.4) (19.0) (35,0) (0,73) 2x1-1/2x1 1.75 1.63 2.00 1.00 0.88 1.31 1.65 86270 DN50x40x25 (44,5) (41.4) (50.8) (25.4) (22,4) (33,3) (0.75) 2x1-1/2x1-1/2 2.06 1,94 2.19 1.31 1.19 1.44 2.03 86272 DNSO x 40 x 40 (52.4) (49,2) (55,5) (33,3) (30,2) (36.6) (0,92) 2x1-112x2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 86273 DN50x40x50 (57,1) (55,5) (63,5) (38,1) (36,6) (38.1) (1.07) 2x2x112 1.50 1.50 1.88 0,75 0.75 1.31 1.50 86222 DN50 x 50 x 15 (38.1) (38,1) (47.8) (19.0) (19.0) (33,3) (0,68) 2x2x314 1.63 1.63 1.94 0.88 0,88 1.38 1.67 86223 DN50x50x20 (49,3) (22,4) (22,4) (35,0) (0,76) 2 x 2 x 1 1,75 2.00 1.00 1.00 1.31 1.91 86224 DNSO x 50 x 25 (44,5) (50.8) (25,4) (25.4) (33,3) (0,86) 2x2x1-114 (41,4)P (56,88) 1.88 2.13 1.13 1.13 1.44 2.05 86225 DN50 x 50 x 32 (47.8) (54,1) (28,7) (28.7) (36.6) (0.93) 2x2x1-1/2 2.00 2.19 1.25 1.25 1.50 2.11 86226 DN50x50x40 (50,8) (55,6) (31,8) (31.8) (38,1) (0.96) 2x2x2-1/2 2.63 2.63 2.38 1.75 3.67 86227 DN50 x 50 x 65 (66.8) (66.8) (60.5) (44.5) (47.8)) (1.66) 2-1/2x2x3/4 1.75 1.63 2.31 0.63 0.88 1.88E44.5) 2.22 86274 DN65x50x20 (44,5) (41.4) (58,7) (15.9) (22,4) (1,01) TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 S Page 8 of 10 TFPI7IO S L hlu-wrowm I IIUI FIGURE 820 FIGURE 830 FIGURE 719 CAP BRASS SEAT UNION PLUG Nominal Pipe Size Figure 820 Figure 830 Figure 719 ANSI A Approx. A B Approx. A Approx. Inches Inches Weight Part Inches Inches Weight Part Inches Weight Part ON (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Lbs. Number (kg) (kg) (kg) 112 0.88 0.15 72776 1.88 0.81 0.47 86207 0.94 0.10 86292 DN15 (22,4) (0106) (47,8) (20,6) (0,21) (23,9) (0,04) 3/4 1.00 0.22 72777 2.00 0.94 0.66 86275 1.13 0.18 86293 DN20 (25,4) (0,10) (50,8) (23,9) (0,30) (28,7) (0,08) 1 1.18 0.33 72824 2.19 0.81 1.08 86276 1.25 0.28 86294 DN25 (30,0) (0,15) (55,6) (20,6) (0,49) (31,7) (0,13) 1-1/4 1.31 0.54 72756 2.50 1.06 1.54 86277 1.38 0.50 86295 0N32 (33,3) (0,24) (63,5) (26,9) (0,70) (35,1) (0,23) 1-1/2 1.38 0.68 72822 2.63 1.19 2.03 86278 1.44 0.70 86296 DN40 (35,1) (0,31) (66,8) (30,2) (0,92) (36,6) (0,32) 2 1.50 1 0.96 72823 3.13 1.63 3.15 86279 1.50 0,90 86297 DN50 (38,1) (0,43) (79,5) (41,4) (1,43) (38,1) (0,41) 2-1/2 1.75 1.80 72825 - - - - - - - DN65 (44,5) (0,82) TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 EO TFPI7IO Page 9 of 10 S FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPLING Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B Approx. ANSI Inches Inches Weight Part Inches Weight Part Inches Inches Weight Part DN (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 1/2x1/2 1.50 0.20 72751 - - - - - - - DN15x15 (38,1) (0109) 1/2 x 1/2 2,00 0.27 72980 - - - - - - - DN15 x 15 (50,8) (0,12) 3/4 x 3/4 1.50 0.22 72981 - - - - - - - DN20 x 20 (3811) (0,10) 3/4 x 3/4 2.00 0.31 73982 - - - - - - - DN20 x 20 (50,8) (0,14) 3/4 x 1/2 1.75 0,69 0.38 86772 0N20 x 15 - - - - - - (43,2) (17,5) (0,17) 1 x1/2 1.06 0.22 72726 1.69 0.50 0.38 86228 DN25 x 15 - - - (26,9) (0,10) (42,9) (12,7) (0,17) 1 x314 1.06 0.18 72762 1.75 0.50 0.53 86229 0N25 x 20 - (26,9) (0108) (43,2) (12,7) (0,24) 1-1/4x1 1.19 0.31 72763 - - - - DN32 x 25 - - - (30,2) (0,14) 1-1/2 x 1.25 0.53 72757 - - - - DN40x25 - - - (31,7) (0,24) 1-112x1-114 1.25 0.35 72764 - - - - DN40 x 32 - - (31,7) (0110) 2x1 1.38 0.75 72759 - - - - DNSO x 25 - - (35,1) (0,34) 2x1-1/4 1.38 0.69 72761 - - - - DN50x32 - - (35,1) (0,31) 2 x 1-1/2 1.38 0.62 72775 - - - - DN50 x 40 - - - (35,1) (0,28) 1 TABLE 7 NOMINAL DIMENSIONS FIGURE 825,827 & 816 (B Description ,J See Fire Protection I Submittal Sheet for Pressure Rating and Listing/Approval Information S tJJCG /Fire & Building / Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap S S General TheFigure40-5 Strap Is an economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40'5 Strap may be used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as we/las wlththeapplicablestandards of the National Fire Protection Association, in addition to the standards of anyotherautho rifles ha ving jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition, The installing contractor or sprinklermanufacturershouldbe contacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing /Approval information. Page 1 of 2 Housing: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coaling Zinc electroplated conforming to ASTM B-633, Type Ill Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade "E" EPDM green color code. (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity, figure number, type of gasket, Grade "E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicablestandards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. September 2004 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid forand properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products orfor products and components which have been subject to misuse, improperinstallation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/orthestandardsofanyotherAuthoritiesHaving Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforit, anyotherobligationin connectionwith the sale of products or parts of products. Tyco Fire Productsshallnotberesponsibleforsprinklersysteni deslgnerrorsorinaccurateorincompleteinformation supplied by Buyer or Buyers representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUTN0T LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTICOFIREPRODUCTSWASINFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENTSHALL1YCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. TIlE F1R1111 WA Al IS MADE UJLWJ OF ANYAM'I ALL SIM WAMMJITILSEXPREOR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARflctt.ARPIrP (B TFPI72O Pipe Nominal Dimensions Hole Net Size Size Wt. A B C D Run x Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. 11/' x 1/II 2.00 1.50 3.50 1.20 1/ie 0.84 50.8 38.1 88.9 30.5 30.2 0.4 1'/4"X3/4" 2.00 1.50 3.50 1.20 1/16 0.88 50.8 38.1 88.9 30.5 30.2 0.4 11/4" 2.31 1.68 3.50 1.20 1/is 1.13 58.7 42.7 88.9 30.5 30.2 0.5 1'/2" X /2" 2.12 1.62 3.50 1.32 13/16 0.84 53.8 41.1 88.9 33.5 30.2 0.4 11/2"X3/4" 2.12 1.62 3.50 1.32 1/I6 0.88 53.8 41.1 88.9 33.5 30.2 0.4 1'/2'x 1" 2.43 1.80 3.50 1.32 1/16 1.13 61.7 45.7 88.9 33.5 30.2 0.5 2" x 1/2' 2.36 1.86 3.74 1.55 1/to 0.88 59.9 47.2 95.0 39.4 30.2 0.4 2"X3/4" 2.36 1.86 3.74 1.55 13'I6 0.95 59.9 472 1 95.0 39.4 30.2 0.4 2' x 1' 2.67 2.04 3.74 1.55 13'ie 1.16 67.8 51.8 95.0 39.4 30.2 1 0.5 21/2"X1/2" 2.61 2.11 4.25 1.80 1/16 0.90 66.3 53.6 108.0 45.7 30.2 0.4 21/2" X 3/40 2.61 2.11 4.25 1.80 1/t6 0.99 66.3 53.6 108.0 45.7 30.2 0.4 2.92 2.29 1 4.25 1.80 13'16 1.21 74.2 58.2 108.0 45.7 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) 1V4"X 1" 8 V/2"X 1" 6 2"xl' 6 21/2" x 1" 4 The friction loss for these outlets Is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. S S Page 2o12 TFP1 720 Figure 40-5 Strap S The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. (:12) General Notes: It is the Designer's responsibility to select products suitable For the intended service and to ensure IS that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (11-1-1 000). Never remove any piping component or corrector modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible For the specific application. . Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. S tqCD /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB - 28,42,5,6, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use In areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the INSTALLER WARNING" that provides cautions with respect to handling and insta!- fat/on of sprinkler systems and com- ponents. Improper handling and/n- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it Is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet 1FP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TV-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. AUGUST, 2007 Model/Sprinkler Identification Numbers TYII3I - Upright 2.81K, 112"NPT 1Y1231 - Pendent 2.8K, 1I2"NPT 1Y2131 - Upright 4.2K, 112"NPT TY2231 - Pendent 4.2K. 1/2"NPT 1Y3131 - Upright 5.6K, 112"NPT ITY3231 - Pendent 5.6K. 112"NPT 1Y4131 - Upright 8.0K, 314"NPT TY4231 - Pendent 8.0K, 314'NPT TY4831- Upright 8.0K, 1/2"NPT TY4931- Pendent 8.0K, 112"NPT (B TFPI7I 7/16j(11,1 mm) STYLE 10or20 RECESSED ESCUTCHEON SSU * DEFLECTOR 2-7/8"(73,0 mmøC-I S TFPI7I ESCUTCHEON PLATE SEATING SURFACE NPT T - 1 2-3/16" (55,6 mm) I 1-1/2" (38,1mm) SSP DEFLECTOR * Page 3 of 10 PENDENT NDENT UPRIGHT CROSS SECTION 1-Frame 3-Sealing 4- 2 - Button Assembly 1 5- Screw 6 - Deflector * Temperature rating is indicated on deflector or adjacent orifice seat on frame. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3 131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT S ESCUTCHEON 1/2' (12,1 mm) PLATE SEATING 3/4fl NOMINAL SURFACE MAKE-IN NPT 2-5/16" _ (58,7 mm) 1-9/16" I (39,7 mm) SSP DEFLECTOR L 2-7/8" PENDENT RECE.& STYLE 30 or4O RECESSED SSU* ESCUTCHEON DEFLECTOR 6* 1/2' 5 (1 mm) OMINAL WRENC (57,2 mm) PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing ..-1 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly,,' 5-Compression orifice seat on frame. Screw FIGURE 4 UICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze 0 Page 4of1O TFPI7I 7/16"(11,1 mm) NOMINAL SSU N MAKE-IN DEFLECTOR PT 2-1/4" 2-3/16" (57,2 mm) -.. I (55,6 4 1-9/16" WRENCH _________ 2 I (39,7 mm) FLATS SID EFLECTOR CROSS PE NT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 ulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to -- Button Assembly Compression orifice seat on frame. Screw FIGURE 5 UICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NP L Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/barl/2) K = 4.2 GPM/psil/2 (60,5 LP1Vl/bar112) K = 5.6 GPM/psi1/2 (80,6 LPM/bar112) K = 8.0 GPM/psil/2 (115,2 LPM/barl'2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing Is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. PA Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. I BULB LIQUID NATURAL BRASS i CHROME PLATED I WHITE"" 1POLYESTER LEAD COATED 5.6 1/2" PENDENT (TY3231) and 135°F/57"C Orange 1,2,3,4,5,6,7 1,2,3,5 I 155°F/68"C Red 175°F/79°C Yellow UPRIGHT (TY3131) 200"F/93°C Green 286"F/141"C Blue NPT RECESSED PENDENT (1Y3231)* Figure 10 135"F157°C Orange 1,2,4,5 N/A Ii 55"F/68"C Red 175°F/79°C Yellow 200"F1934C Green 135°F/57°C Orange 1,2,3,4,5 N/A RECESSED PENDENT cry3231r Figure 11 155"F/68"C Red 175°F/79"C Yellow 200°F193"C Green 8,0 3/4,, PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57*C Orange 1,2, 3,4,5, 6, 7 1,2,5 155°E/68"C Red 175"F179"C Yellow 200"F/93"C Green 286"F/141"C Blue NPT RECESSED PENDENT (TY4231)" Figure 12 135"F/57"C Green 1,2,4,5 N/A 155"F/68"C Orange 175°F/79"C Red 200"F/93°C Yellow RECESSED PENDENT fTY4231 Figure 13 135°F/57"C Orange 1,2,3,4,5 N/A 155°F/68"C Red 175"F/79°C Yellow 200°F/93°C Green 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135"F/57"C Orange 1,2,4,5,6 1,2,5 155°F/68"C Red 175°F!79"C Yellow 200°F193°C Green 286°F/141°C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City or New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS S S S TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED I POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2" RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 OR UPRIGHT (TY3131) 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE N/A PENDENT (1Y4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (1Y4131) RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT(TY4931) 1/2' and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (1Y4831) NOTES: 1. The maximum working pressure of 250 psi (17.2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratorles,lnc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1350F/570C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.!bs. (13,4 to 26,8 Nm). A maximum of 30 ft./bs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed TFPI7I - 2-718" DIA. 5/8±1/4' (730 mm) I 314"(19,1 mm (15,9±6,4 mm) 2-1/4' DIA. I 1/4-(6, FACE OF (57,2mm) I MO TING SPRINKLER PLATE FITTING (3,2 mm) ;5.6 SERIES 1-1/4'(31,8 mm) I TVFRB 314' (19,1 mm) FIGURE 10 TY-FRB RECESSED PENDENT ECE 3/4 INCH TOTAL ADJUSTMENT 10 RECESSED ESCUTCHEON K-FACTOR, 1/2 INCH NPT - 2-718' DIA. 5/8±1/4' (73,0 mm) 3/4' 09,1 mm) (15,916,4 mm) - 2-114' DIA. 1/4' (6,4 m (57,2 mm) FACE OF MOUXTING SPRINKLER ATE FITTING / - (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16' (33,3m TYFRB 13/16.(20,6 mm) FIGURE 12 S IES TY-FRB RECESSED PENDENT WIT 0-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 - 2-7/8' DIA. - (73,0 mm) 1/2±1/8' 112"(12,7 m (12,7±3,2 mm) or 2-1/4' DIA. 114' (6,4 m) FACE OF (57,2 mm) MO FITTING TING SPRINKLER PLATE (3.2 mm) _ 1 f \ MOUNTING SURFACE CLOSURE SERIES 1-1/4'(31,8mm) TY.FRB 1'(25,4 mm) FIGURE 11 RIES TY-FRB RECESSED PENDENT WI TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. 1/2±1/8' (73.0 mm) 1/2"(12,7 mm) (12,7±3,2 mm) 2-1/4' DIA. ..........j 1/4" (6,4 (57,2 mm) FACE OF MO TING SPRINKLER LATE FITTING I 1/8' I - (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16' (33,3 mm) TY'FRB 1-1/16" (27,0 mm) FIGURE 13 RIES TY-FRB RECESSED PENDENT WIT TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- rosion resistant Coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A' USED FOR 1/2" NPT MODELS) WRENCH RECESS (END 'B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. 8 Page 10 of 10 TFPI 71 PIN 57-XXX-X-XXX I L MODEL/SIN 330 1 2.8K UPRIGHT (1/2'NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (112"NPT) TV2131 341 4.2K PENDENT (1/2"NPT) 1V2231 5.6K UPRIGHT (1/2'NPT) 1Y3131 L371 7 5.6K PENDENT (112NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (314'NPT) TY4231 360 8,0K UPRIGHT (1/2"NPT) TY4831* 361 8.0K PENDENT (1/2NPT) TY4931 I I I 135 155 175 200 286 RATING SPRINKLER 135°F/57*C 155*F/68*C 1 NATURAL BRASS 4 WHITE POLYESTER 175°F179°C 3 WHITE (RAL9OIO) 200*F/93C 9 CHROME PLATED 286°F/141°C 7 I LEAD COATED * Eastern Hemisphere sales only. TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited. Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or Inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 IMPERIAL MAX REC. I LOAD LBS. METRIC PIPE ROD PIPE ROD 1/2 3/8 400 10 3/4 3/8 400 20 10 1 3/8 400 25 10 11/4 3/8 400 32 10 11/2 3/8 1 400 40 10 2 3/8 400 50 10 21/2 3/8 600 65 10 3 600 ao 10 31/2 600 to - 1000 -100 10 5 1250 125 -- 12 6 1250 150 12 '2 E] 8 1250 200 * Order Part #300m Note: 1/2 Ring Hanger not <FM> approved JAcn 300 RING HANGER S I I thru 4 inch pipe 1/2 and 314 Inch pipe 5 thru 8 Inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized tc G-90 specification. FINISH - Mil. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H- 171(Type 10), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 650°F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - lthru4 inch: * Offset edge for EASY pipe insertion. 1 thru 8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru 3 inch: * UL listed to accept AFCON #310 Surge Restrainer. * Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index 02/01 S 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 NOTE; 'maximum Temperature: 750°F S SIZE - 3/8 thru 7/8 inch rod in 1 inch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. S LII] ( D I #14 (Item #100-black) Sanimys 1/4", 3/8" rod WOOD - Sammys WOOD - 1/4" Rodrinri M ount) Use #14 Nut Driver (Item #100) Item# Model Shk Lgth Shk Dia Box Qty Weight (per 100) Case Qty 20 GST.750 3/4 1/4 100 4.75 1000 21 GST 100 1 1/4 100 5.00 1000 22 GST 200 2 1/4 100 1 6.50 1000 23 GST 300 3 1/4 100 7.50 24 GST 600 6 1/4 50 9.00 E5O Not less than 2" nominal width (11/2") iJ'14 c.iE )ist I Truss as manufacturer for led Installation point. ig may be required is #27 and #06. Tools available on page 9. q Wood Joist WOOD Yk4 Rod (Vertical 1Ik1iTfl1Th Use #14 Nut Driver (Item #100) Approvals Item # Model Shk Lgth Shk Dia FMTest Loalb. ULTest Loadlb. UIJFMActual Pipe Size Pullout Box Qty 10 GST.75 3/4 1/4 564# -6 Ply 100 NFPA 11 GST10 1 1/4 2104 - 7/16 OSB100 670# - 3/4" Ply UL-FM-NFPA 12 GST 20 2 1/4 940# 850# 3/4-2 1/2 1760# - Fir 100 UL-NFPA * 27 G8T25-380 21/2 3/8 1500# 4 2113#-Fir 50 UL-FM-NFPA 13 GST30 3 1/4 1475# 15004 3/4-4 20604 - Fir 100 NFPA 403 GST 40 4 1/4 2180# - Fir 50 NFPA 1 14 IGST60 6 1 1/4 22304-Fir 50 #I4SW (Item #101-red) Sidewinders & Sammys 1/2" rod WOOD Rod. Tr&t1LurnnT1 Use #14SW Nut Driver (Item #101) Item# Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight (per 100) Case Qty 8 GST2 2 1/4 1760#-Fir 50 7.00 500 * 06 GST2.5-380 21/2 3/8 2113#-Fir 50 10.00 500 15 IGST3 1 3 1 1/4 1 2275#-Fir 1 50 1 10.50 500 16 JGST4 1 4 1 1/4 1 2180#-Fir 50 10.60 500 17 JGST6 1 6 1 1/4 1 2230# - Fir 50 10.95 500 Double Sheetrock Calling Minimum 2" imbedment into base material for NFPA 13 compliance For vertical use. Install in center of lowerface. 22 Page 4 Note: Screws must be installed with appropriate nut driver to comply with warranty 4.3.8 HDI & HDI-L Drop-In Anchor 4.3.8.1 Product Description 4.3.8.2 Material Specifications 4.3.8.3 Technical Data 4.3.8.4 Installation Instructions 4.3.8.5 Ordering Information 4.3.8.1 Product Description The Hilti HDI/HDI-L Drop-In anchor is an • Intelligent expansion section internally threaded, flush mounted adapts to the base material and expansion anchor for use in concrete. reduces number of hammer blows up to 50% (HDI-L) Product Features Guide Specifications HDI Anchor, setting tool and Hilti drill bit form a matched tolerance system to provide reliable fastenings Allows shallow embedment without sacrificing performance Lip provides flush installation, consistent anchor depth, and easy rod alignment (HDI-L) Lip allows accurate flush surface setting, independent of hole depth (HDI-L) Ideal for repetitive fastenings with threaded rods of equal length Expansion Anchor Expansion anchors shall be flush or shell type and zinc plated in accordance with ASTM B 633, SC 1, Type Ill. Anchors shall be Hilti HDI/HDI-L anchors as supplied by Hilti. Installation Install shell or flush type anchors in holes drilled with Hilti carbide tipped drill bits. Install anchors as per manufacturer's recommendations. 4.3.8.2 Material Specifications HDI/HDI-L, 1/4", 3/8", 1/2", and HDI 5/8" and 3/4" are manufactured from mild carbon steel which is plated with a zinc finish for corrosion protection in accordance with ASIM B 633, SC 1, Type Ill HDI Stainless Steel material meets the requirements of AlSI 303 4.3.8.3 Technical Data HDl/HDI-L Specification Table Anc HDI/HDl-L HDI 1/4 3/8 1/2 5/8 3/4 Size In. Details (mm) (6.4) (9.5) (12.7) (15.9) (19.1) dba Nominal Bit diameter in. 3/8 1/2 5/8 27/32 1 'mom Std. depth of embed. in. 1 1-9/16 2 2-9/16 3-3/16 Anchor length (mm) (25) (40) (51) (65) (81) hl Hole depth fth Useable thread in. 7/16 5/8 11/16 7/8 1-3/8 length (mm) (11) (15) (17) (22) (34) Threads per inch 20 16 13 11 10 h mm. base material in. 3 3-1/8 4 5-1/8 6-3/8 thickness (mm) (76) (79) (102) (130) (162) Tmax m, tightening ft-lb 4 11 22 37 80 torque (Nm) (5.4) (14.9) (29,8) (50.2) (108.5) Listincis/Aoorovals City of Los Angeles Research Report No. 23709 (HDI Only) FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems (3/8" - 3/411) (HDI and HDI-L) UL (Underwriters Laboratories) UL 203 Pipe Hanger Equipment for Fire Protection Services (3/8' - 3/4") ILAQPJCS FM c ss,"4, Combined Shear and Tension Loading /Nd \5/3 /Vd )5/3 + :s 1.0 (Ref. Section 4.1.2.7) (B 352 HuLl. Inc. (US) 1-800-879-8000 1 www.us.hUtl.com I en espaicd 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 1 www.hlitl.ca I Product Technical Guide 2008 fl HDI & HDI-L Drop-In Anchor 4.3.8 Carbon Steel HDI Allowable Loads in Concrete Anchor size 2000 psi (13.8 MPa) 4000 psi (27.6 MPa) 6000 psi (41.4 MPa) ln.(mm) Tension lb (kN) Shear lb (kN) Tension lb (kN) Shear. lb (kN) Tension lb (kN) Shear lb (kN) 1101 HDl-L HDI 1101-1 HDI HDI-L HDI HDl-L HDI HDl-L HOP HDl-L 1/4 16.4) 500( 2.2) 500(2.2) 450( 8.0) 450(8.0) 570( 2.5) 570(2.5) 625( 2.8) 625(2.8) 790( 3.5) 790) 3.5) 700( 3.1) 700( 3.1) 3/8 (9,5) 890( 4.0) 890(4.0) 965( 4.3) 965(4.3) 1115( 5.0) 1115(5.0) 1250( 5.6) 1250(5.6) 1360( 6.0) 1360( 6.0) 1500( 6.7) 1500) 6.7) 1/2 (12,7) 1120( 5.0) 1120(5.0) 1500( 6.7) 1500(6.7) 1785( 7.9) 1785(7.9) 2125( 9.5) 1940(8.6) 2345(10.4) 2345(10.4) 2500(11.1) 2500(11.1) 5/8 (15.9) 1875( 8.3) - 2500(11.1) - 2920(13.0) - 3250(14.5) - 3715(16.5) - 3750(16.7) - 3/4 (19.1) 2500(11,1) - 3875(17.2) - 4065(18,1) - 5000(22.2) - 5565(24.8) - 5500(24.5) - Note: The ultimate shear and allowable shear values are based on the use of SAE Grade 5 bolts, (f = 85 ksi, F, = 120 ksi) with the exception of the 1/4" HDl/HDI-L in 1' = 6000 psi concrete which is based upon the use of a SAE Grade 8 bolt (lv = 120 ksi, F, = 150 ksi). Carbon Steel HDI Ultimate Loads in Concrete Anchor size 2000 psi (13.8 MPa) 4000 psi (27.6 MPa) 6000 psi (41.4 MPa) 15.0m) Tension lb (kN) Shear lb (kN) Tension lb (kN) Shear lb (kN) Tension lb (kN) Shear lb (kN) HDI 1101-1 HDI HDl-L HOP HDl-L HDI HDI-L HDI HDI-I HDI HDl-L 1/4 (6.4) 1996( 8.9) 1995( 8.9) 1800( 8.0) 1800( 8.0) 2270(10.1) 2270(10.1) 2500(11.1) 2500(11.1) 3150(14.0) 3150(14.0) 2800(12.5) 2800(12.5) 3/8 ( 9.5) 3555(15.8) 3555(15.8) 3850(17.1) 3850(17.1) 4460(19.8) 4480(19.8) 5000(22.2) 5000(22.2) 1 5430(24.2) 5430(24.2) 6000(26.7) 6000(26.7) 1/2 (12.7) 4470 (19.9) 4470(19.9) 6000(26.7) 6000(26.7) 7140(31.8) 7140(31.8) 8500(37.8) 7750(34.4) 9375(41.7) 9375(41.7) 10000(44.5) 10000(44.5) 5/8 (15.9) 7500(33.4) - 0000(44.5) - 1685(52.0) 1 - 13000(57.8) - 14865(66,1) - 15000(66.7) - 3/4 (19.1) 10000(44.5) - 5500(69.0) - 8260(72,3) 1 - 20000(89.0) - 2250(99.0) - 22000(97.9) - Carbon Steel HDI Allowable Loads in Lightweight Concrete and Lightweight Concrete over Metal Deck1'2 Anchor Size in. (mm) Anchor Installed in 3000 psi (20.7 MPa) It. Wt. Concretes Anchor Installed Through Steel Deck Upper Flute Into 3000 psi (20.7 MPa) It. Wt. Concrete4 Anchor Installed Through Steel Deck Lower Flute Into 3000 psi (20.7 MPa) l.t. V/f. Concrate4 Tension, lb (kN) Shear, lb (kN) Tension, lb (kN) Shear, lb (kN) Tension, lb (kN) Shear, lb (kN) 1/4(6.4) 465(2.1) 340(1.5) 530(2.4) 335(1.5) 375(1.7) 250(1.1) 3/8(9.5) 755 (3.4) 940 (4.2) 880 (3.9) 1010 (4.5) 500 (2.2) 500 (2.2) 1/2(12.7) 1135 (5.0) 1700(7.6) 1105 (4.9) 1755 (7.8) 625 (2.8) - 750 (3.3) 5/8(15.9) 1465(6.5) 2835(12.6) - - 875 (3.9) 875 (3.9) 3/4(19.1) 2075 (9.2) 3680(16.4) - - 1250(5.5) 1000 (4.4) 1 The allowable values are based on the use of SAE Grade 2 bolts installed in the anchors. 2 Based on using a safely factor of 4.0. Stainless Steel HDI Allowable Loads in Concrete 3 The tabulated shear and tensile values are for anchors installed in structural light- weight concrete having the designated ultimate compressive strength at the time 01 installation. The concrete must comply with ASTM C 330-77. 4 The tabulated shear and tensile values are for anchors installed through 20 gauge intermediate decking into structural lightweight concrete having the designated ultimate strength at the time of installation. The concrete must comply with ASTM C 330-77. Anchor size in. (mm) 4000 psi (27.6 MPa) 6000 psi (41.4 MPa) Tension lb (kN) Shear lb (kN) Tension lb (kN) Shear lb (kN) SS HDI - 1/4 (6.4) 480 (2.1) 600 (2.7) 740 (3.3) 600 (2.7) SS HDI-3/8 (9.5) 1040 (4.6) 1230 (5.5) 1460 (6.5) 1230 (5.5) SS HDI - 1/2 (12.7) 1840 (8.2) 2760 (12.4) 2410 (10.7) 2760 (12.3) SS HDI -5/8 (15.9) 2630(11.7) 4510 (20.1) 3770 (16.8) 4510 (20.1) SS HDI - 3/4 (19.1) 3830 (17.0) 5580 (24.8) 5030 (22.4) 5580 (24.8) Note The ultimate and allowable shear values are based on the use of Type 18-8 bolts. Stainless Steel HDI Ultimate Loads in Concrete Anchor size in. (mm) 4000 psi (27,6 MPa) 6000 psi (41.4 MPa) Tension lb (kN) Shear lb (kN) Tension lb (kN) Shear lb (kN) SS HDI - 1/4 (6.4) 1930 (8.6) 2400 (10.7) 2950 (13.1) 2400 (10.7) SS HDI -3/8 (9.5) 4170 (18.5) 4920 (21.9k 5850 (26.0) 4920 (21.9) SS HDI -1/2 (12.7) 7350 (32.7) 11040 (49.1) 9630 (42.8) 11040 (49.1) SS HOP - 5/8 (15.9) 10540(46.9) 18040 (80.2) 15100 (67.2) 18040 (80.2) SS HOP - 3/4 (19.1) 15340 (68.2) 22320 (99.3) 20130 (89.5) 22320 (99.3) 2 Hilti, Inc. (US)1-800'879-8000 1 www.us.hflti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1.800-363-4458 1 www.hlltLca I Product Technical Guide 2008 363 '1 U 4.3.8 HDI& HDI-L Drop-In Anchor Anchor Spacing and Edge Distance Guidelines (See Anchoring Technology Section 4.1.3) N Anchor Spacing Adjustment Factors s = Actual Spacing Smin = 2.0 hnom Scr = 3.5 h00 Scr Edge Distance Adjustment Factors c = Actual edge distance cmjn = 2.0 h,t,,m Ccr = 3.0 hnom 3.0- Shear& 2.0- Smin h000, I I 1.0 I 1.0 0 I I o 0 .2 .4 .6 .8 1.0 Anchor Spacing Adjustment Factor (tA) Ccr Shear Cmin---z I I .2 .4 .6 .8 1.0 Edge Distance Adjustment Factor (f, f,) Influence of Anchor Spacing & Edge Distance fA, fR Anchor Size In. (mm) hnom In. (mm) 1/4(6.4) 1(25) 3/8(9.5) 1-9/16(40) 1/2(12.7) 2(51) 5/8(15.8) 2-9/16(65) 3/4(19.1) 3-3/16(81) h,m = standard embedment depth S Load Adjustment Factors (Anchor Spacing) fA Load Adjustment Factors (Edge Distance) f8 Tension/Shear Loads Tension, f,, Shear, f, Spacing in.() Anchor Diameter Edge Distance in. (mm) Anchor Diameter Anchor Diameter 1/4 318 s c 1/2 5/8 314 1/4 3/8 1/2 5/8 3/4 1/4 3/8 1/2 5/8 3/4 2 (fl_ .50 2 ( 51) .80 - - .65 2-1/2 ( 67_ - - 2-1/2 (64) 0 - 83_ - - _(i) .83 5° 3(76) 65 3-1/2 L891 1.0 .58 3-1/2 (_89) - .85 - - .73 - 4 (102) 9.50 4(102) 1.80 .85.65 4-1/2(114) 1 .79 .58 - 4-1/2(114) - .98 .85 - - - .96 1 .74 - 5(127) 9067 .50 - 5(127) 1.09080 1083.65 5-1/2(140) 1.0.75.55 5-1/2(140) .95.83 .91.70 6(152)J _6(152)j _ 7(178) tO 34 .57 6-1/2(165) 1 .80 84 .65 8(203) .87 .67 7(178) - - .95 .84 - - - .91 .72 9(229) 1.0 77 8(203) 10(254) 9(229) - - - - .96 - - - .94 11 (279) 10 (254) - - - - 1.0 - - - - 1.0 12 (305) 1.0 Sam = 2.0 hnom, S,, = 3.5 h,,, fA = 0.33 s- 0.17 F._. for Sc;>S>Smin Cmjn = 2.0 C, = 3.0 h,,m fRN = G.2 c+ 0.4 ha,m for Ccr>C > cmi, Cain = 2.0 Cr = 3.0 hrom fFv = 0.35 c- 0.05 h for Cc>C >Cmm • 364 HuLl, Inc. (US) 1-800-879-8000 1 www.us.hiltl.com I en español 1-800.879-5000 1 Huh (Canada) Corp. 1-800-363-4468 1 www.hlltl.ca I Product Technical Guide 2008