HomeMy WebLinkAbout2675 GATEWAY RD; ; AS080179; Permit8/17/22, 11:24 AM AS080179 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2675 GATEWAY RD Permit Type: SPRINK Parcel No: 2131910800 Lot #: 0 Permit No: AS080179 Status: ISSUED Applied 12/4/2008 Approved: 12/4/2008 Reference No.: Issued: 12/4/2008 PC #: Inspector: Project Title: RUBIO'S GRILL T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: ALLREADY FIRE SPRINKLER CO. 818N GRAND AVE COVINA, CA 91723 818-913-6720 Fees ($) Add'l Fees ($) Total ($) ($) Balance 130 L130 0 0 1/1 tqco /Fire & Building I Products r r I I LL 3" P V Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series TY-FRB - 2.8,4.2,5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet 1FP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII3I - Upright 2.81K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT TY2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.21K, 1/2"NPT TY3131 - Upright 5.61K, 1/2"NPT TY.23 t- Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.01K, 3/4"NPT TY4231 - Pendent 8.0K, 3/4"NPT TY4831- Upright 8.01K, 1/2"NPT TY4931- Pendent 8.01K, 1/2"NPT Page 1 of 10 AUGUST, 2007 TFPI7I rriJ 2-7/8" (73,0 mm) DIA. 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3/16" (55,6 mm) 6* WRENC FLATS 1/2" NPT 1/2" kin,- Page 2 of 10 ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) SSP DEFLECTOR * TFPI7I 7/16(11,1 mm) STYLE 10 or 20 NOMINAL RECESSED SSU MAKE-IN ESCUTCHEON UI-< DEFLECTOR / 7/16" (11,1 mm) I NOMINAL MAKE-IN 5 2-3/16" " H (55,6 mm) , ' 1/2" NPT _ 7 ' PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT(TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT STYLE 10or20 RECESSED ESCUTCHEON ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING 1/2" NOMINAL SURFACE MAKE-IN 2-3/16" NPT (55,6 mm) 1-1/2" (38,1 mm) SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA. SSU * DEFLECTOR PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT ESCUTCHEON 7/16(11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED 1/2 SURFACE MAKE-IN ESCUTCHEON NPT 2-3/16" '1 (55,6 mm) 1-1/2" (38,11 mm ) WRENC FLATS / * _ SSP DEFLECTOR 2-7/8" (73,0 mm) DIA. SSU * DEFLECTOR 7/16" 11,1 mm) JOMINAL MAKE-IN 2-3/16' (55,6 mm) 6* 1/2" NPT 1/2" (12,7 mm) NOMINAL MAKE-IN 2-1/4" (57,2 mm) 3/4" NPT UPRIGHT CROSS SECTION TFPI7I Page 3 of 10 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT STYLE 30 or 40 RECESSED SSU* ESCUTCHEON DEFLECTOR WRENCH FLATS SSP DEFLECTOR * I 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING NOMINAL SURFACE MAKE-IN NPT 2-5/16" (58,7 mm) 1-9/16" I (39,7 mm) 7/16" (11,1 mm) NOMINAL 1/2" MAKE-IN NPT 2-1/4" (57,2 mm )RENCH1-9/16' (39,7 IWA mm) FLATS DEFLECTOR PENDENT UPRIGHT CROSS SECTION SSU * DEFLECTOR IM I Page 4 of 10 TFPI7I 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/barl'2) K = 4.2 GPM/p5i112 (60,5 LPM/bar1/2) K = 5.6 GPM/psi112 (80,6 LPM/barl/2) K = 8.0 GPM/psi112 (115,2 LPM/barll2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. TEPI7 I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE" IPOLYESTER 2.8 1/2" PENDENT (TY1231) and UPRIGHT (TYII3I) 135°F/57°C Orange 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY1231)* Figure 6 135°F/57°C Orange 1, 2, 5 155°F/68C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY1231)** Figure 7 135°F/57°C Orange 155F/68°C Red 175°F179°C Yellow 200°F/93°C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F/57°C Orange 1,2 155°F/68°C Red 175°F/79°C Yellow 200°F/93C Green 286°F/141°C Blue RECESSED PENDENT (TY2231)* Figure 8 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY2231)** Figure 9 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-F. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Page 5 of 10 Page 6 of 10 TFPI 71 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WI•IITE POLYESTER LEAD COATED 5.6 PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1, 2,3,4,5,6,7 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93"C Green 286°F/141°C Blue 1/2" NPT RECESSED PENDENT (TY3231)* Figure 10 135°F/57"C Orange 1,2,4,5 N/A 155°F/68°C Red 175"F/79"C Yellow 200°F/93"C Green RECESSED PENDENT (TY3231)** Figure 11 135°F/57"C Orange 1,2,3,4, 5 N/A 155"F/68"C Red 175°F/79°C Yellow 200°F/93°C Green 8.0 PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1, 2,3,4,5,6,7 1,2,5 155°F/68°C Red 175°F/79"C Yellow 200°F/93°C Green 286°F/141°C Blue 3/4,, NPT RECESSED PENDENT (TY4231)* Figure 12 135°F/57°C Green 1, 2, 4, 5 N/A 155°F/68"C Orange 175°F/79°C Red 200°F/93"C Yellow RECESSED PENDENT (TY4231)** Figure 13 135°F/57°C Orange 1,2, 3,4, 5 N/A 155°F/68°C Red 175"F/79"C Yellow 200°F/93°C Green 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57°C Orange 1, 2,4, 5, 6 1,2,5 155"F/68"C Red 175°F/79°C Yellow 200"F/93"C Green 286°F/141"C I Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-F. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (1Y3131) 175 PSI (12,1 BAR) N/A 1/2" RECESSED PENDENT NPT (1Y323) PENDENT (TY4231) and 4.2 UPRIGHT (1Y4131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (TY4231) PENDENT (1Y3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (1Y4131) RECESSED PENDENT NPT (TY4231) N/A 80 PENDENT (TY4931) 1/2' and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (1Y4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Page 8 of 10 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING DI AT 1/8' (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)1 TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING rLtu I (3,2 mm) 1-1/4" (31,8 mm)1 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I 2-7/8" DIA. - (73,0 mm) I 1/2±1/8" I 1/2" (12,7 mm) r (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I I I FACE OF T57,2 mm) MOUNTING SPRINKLER PLATE I FITTING 1/8" (32 mm) I \ fMOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - 1/211/8" (73,0 mm) 1/2(12,7mm) fl (12,713,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF H (572mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (32 mm) MOUNTING SURFACE SERIES 1-1/4" (31,8 CLOSURE TY.FRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 5/8±114 (159±6,4 mm) FACE OF SPRINKLER FITTING 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that itcontrols, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- TFPI7I 2-7/8 DIA. - (73,0 mm) 3/4(19,1 mm) 5/8±1/4" (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING # 1/8" SPRINKLER PLATE FITTING _ - (3,12 mm) 7 MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) I TY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) I (57,2 mm) MOUNTING rLJ.,I I 1/8" 3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) E (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF 57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" MOUNTING SURFACE SERIES 1-1/4"(31,8mm) CLOSURE TY-FRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER I I _ PLATE FITTING (3.2 mm I - MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. Page lOoflO TFPI7I P/N 57-XXX-X-XXX I I TEMPERATURE I MODEL/SIN I I SPRINKLER RATING 330 2.8K UPRIGHT (1/2"NPT) TY1131 _[ 135 135°F/57°C 331 2.8K PENDENT (1/2"NPT) 1Y1231 1 NATURAL BRASS 155 155°F/68C 340 4.2K UPRIGHT (1/2"NPT) 1Y2131 4 WHITE POLYESTER 175 175°F/79°C 341 4.2K PENDENT (1/2"NPT) TY2231 3 WHITE (RAL90I0)* 200 200°F/93°C 370 5.6K UPRIGHT (1/2"NPT) TY3131 9 CHROME PLATED 286 286°F/141°C 371 5.6K PENDENT (1/2"NPT) 1Y3231 F LEAD COATED - 390 8.0K UPRIGHT (3/4NPT) TY4131 391 8.0K PENDENT (3/4NPT) TY4231 * Eastern Hemisphere sales only. 360 8.0K UPRIGHT (1/2"NPT) TY4831* 361 1 8.OK PENDENT (1/2'NPT) 1Y4931* TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqC0 /Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series DS-1 - 56 K-factor Dry Type Sprinklers Standard Response, Standard Coverage General Description The Tyco® Series DS-1, 5.6 K-factor, Standard Response, Standard Cover- age, Dry Type Sprinklers are decorative 5 mm glass bulb automatic sprinklers designed for the following typical uses: where pendent sprinklers are re- quired on dry pipe systems that are exposed to freezing temperatures (e.g. sprinkler drops from unheated portions of buildings) where sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g. sprinkler drops from wet sys- tems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping exten- sions through a wall to protect an unheated area of a building) where sprinklers are used on sys- tems that are seasonably drained to avoid freezing (e.g. vacation re- sort areas) WARNINGS The Series DS-1 Dry Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. The Series DS-1 Dry Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers TY3255 - (Pendent) TY3155 - (Upright) TY3355 - (Horizontal Sidewall) Technical Data Approvals UL and C-UL Listed. FM and NYC Approved. (Refer to Table A) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connection 1 inch NPT (Standard Order) ISO 7-Ri Discharge Coefficient K = 5.6 GPM/psi112 (80,6 LPM/bar112) Temperature Ratings Refer to Table A Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated or Chrome Plated, Brass Plated Physical Characteristics Inlet.....................Copper Plug ....................Copper Yoke ..............Stainless Steel Casing . . . . Galvanized Carbon Steel Insert ...................Bronze Bulb Seat ..........Stainless Steel Bulb ......................Glass Compression Screw ........Bronze Deflector ................. Bronze Frame ...................Bronze Guide Tube.........Stainless Steel Water Tube .........Stainless Steel Spring.............Stainless Steel Sealing Assembly ................ Beryllium Nickel w/Teflon* Escutcheon ..........Carbon Steel *Registered Trademark of DuPont Patents U.S.A. Patent No. 5,188,185 Page 1 of 8 JANUARY, 2008 TFP500 Page 2 of 8 TFP500 SPRINKLER FINISH TY3255 Pendent TY3255 Pendent TY3355 Hor. Sidewall w/ Standard w/ Std. Escutcheon with top of Recessed Escutcheon (Ref. Fig. 5) Deflector-to-Ceiling (Ref. Fig. 3) w/ Deep Escutcheon distance of w/ Wide Flange (Ref. Fig. 6) 4 to 12 inches Recessed Escutcheon w/o Escutcheon (100 to 300 mm) (Ref. Fig. 4) (Ref. Fig. 7) w/ Std. Escutcheon (Ref. Fig. 9) w/ Deep Escutcheon TY3155 Upright (Ref. Fig. 10) w/o Escutcheon w/o Escutcheon (Ref. Fig. 8) (Ref. Fig. 11) Temperature Bulb Color Natural Chrome White Natural Chrome White Natural Chrome White Rating Code Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F/57°C Orange 1,2,3,4 1,2,4 1,2,3,4 1,2,4 1*,2*,3**,4 1*,2*,4 155°F/68°C Red 1, 2, 3, 4 1,2,4 1, 2, 3, 4 1, 2, 4 1*, 2*, 3** 4 1*, 2*, 4 175°F/79°C Yellow 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1*, 2*, 3** 4 1*, 2*, 4 200°F/93°C Green 1,2,3,4 1,2,4 1,2,3,4 1,2,4 1*,2*,3**,4 1*,2*,4 286°F/141°C Blue N/A 1, 2, 3, 4 1, 2, 4 1*, 2*, 3** 4 1*, 2*, 4 360°F/182°C Mauve N/A 1,2,3,4 1,2,4 1*, 2*, 4 1*, 2*, 4 Notes: Listed by Underwriters Laboratories, Inc (Maximum order length of 48 inches). Listed by Underwriters Laboratories for use in Canada (Maximum order length of 48 inches). Approved by Factory Mutual Research Corporation (Maximum order length of 48 inches) Approved by the City of New York under MEA 352-01-E. * Light and Ordinary Hazard Occupancies Only. ** Light Hazard Occupancies Only. N/A - Not Available. TABLE A SERIES DS-1, STANDARD RESPONSE - STANDARD COVERAGE, DRY TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH INLET GASKETED SPRING ' PLATE SEAL - YOKE SPRING CASING WATER TUBE INSERT GUIDE TUBE BULB SEAT FRAME - L VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1, STANDARD RESPONSE DRY TYPE SPRINKLERS ASSEMBLY - WRENCH RECESS WRENCH FLAT PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCH FLATS FIGURE 2 W-TYPE 7 SPRINKLER WRENCH 1FP500 Page 3 of 8 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) ---. - FACE OF H SPRINKLER 1 11 FITTING L_ _i ORDER LENGTHS: 3-1/2 to 48" (88,9 to 1219,2 mm) IN 1/4 (6,4 mm) 2-1/4 DIA. INCREMENTS (57,2 mm) CEILING U F 7-~ FACE OF FIGURE 3 TY3255 PENDENT wi STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) r- FACE OF H SPRINKLER LU FITTING ORDER LENGTHS: 3-1/2' to 48" (88,9 to 1219,2 mm) IN 1/4' (6,4 mm) 3' DIA. INCREMENTS (76,2 mm) FACE OF F CEILING _ rim) FIGURE 4 TY3255 PENDENT wi WIDE FLANGE RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) ------------------- FACE OF SPRINKLER L.. FITTING - L ORDER LENGTHS: m 2-1/2" to 48" 1-3/4" DIA. (63,5 to 1219,2 mm) (44,5 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF CEILING I ct 3" DIA. 2-3/16" ± 1/8" (55,6 ± 3,2 mm) (76,2 mm) FIGURE 5 TY3255 PENDENT wi STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) r --- FACEOF F-IN SPRINKLER I FITTING ORDER LENGTHS: 3-1/2 DIA. 1/2 to 46" (88,9 mm) (12,7 t '2D IN 1 INCREMENTS FACE OF CEILING 4-1/4" + 1/8 (1080+32 mm) FIGURE 6 TY3255 PENDENT wi DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF H SPRINKLER FITTING LJ ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4"(44 ' 5 mm) DEFLECOR TO CEILING FIGURE 7 TY3255 PENDENT w/o ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 8 TY3155 UPRIGHT wlo ESCUTCHEON ORDER LENGTHS: 1/2"t045-3/4"(12,7to1162,1 mm) IN 1/4' (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING Lm----- SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF MOUNTING SURFACE / ~2 1 ____ 4-13/16..± 1/8" (122,2 ± 3,2 mm) /2"DIA. ,5 mm) 3-1/2" DIA. (88,9 mm) /3.50 CENTERLINE 5/16" OF WATERWAY (7,9 mm) FIGURE 10 TY3355 HORIZONTAL SIDEWALL wi DEEP ESCUTCHEON Page 4 of 8 ORDER LENGTHS: 2-1/2" to 48" (63,5 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS 4" ±1/8" (101,6 ± 3,2 mm) FACE OF FACE OF 1-3/4' DIA. SPRINKLER MOUNTING (44,5 mm) FITTING SURFACE _ 3"DIA. SPRINKLER FITTING / (76,2 mm) (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 TY3355 HORIZONTAL SIDEWALL wi STANDARD ESCUTCHEON TFP500 Operation When the Series DS-1 is in service, water is prevented from entering the assembly by the Plug & Belleville Seal- ing Assembly (Ref. Figure 1) in the Inlet of the Sprinkler. The glass Bulb con- tains a fluid that expands when ex- posed to heat. When the rated tem- perature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to ex- pand and push the Water Tube as well as the Guide Tube outward. This ac- tion simultaneously pulls inward on the Yoke, withdrawing the Plug & Belleville Seal from the Inlet allowing the sprin- kler to activate and flow water. ORDER LENGTHS: 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 2-1/4" (57,2 mm) - FACE OF DEFLECTOR TO - SPRINKLER I MOUNTING 1 SURFACE URFACE "---I---'. 1 350 I r' 5/16" r- (7,9 mm) I SPRINKLER FITTING (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 11 TY3355 HORIZONTAL SIDEWALL w/o ESCUTCHEON Design Criteria The TycoO Series DS-1 Sprinklers are intended for use in fire sprinkler sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The 1 inch NPT Series DS-1 Sprin- klers are to be installed in the 1 inch NPT outlet or run of malleable or duc- tile iron threaded tee fittings that meet the dimensional requirements of ANSI B16.3 (Class 150) or cast iron threaded tee fittings that meet the dimension- al requirements of ANSI B16.4 (Class 125). The Series DS-1 Sprinklers may also be installed in the 1 inch NPT out- let of a Grinnell Figure 730 Mechani- cal Tee; however, the use of the Figure 730 for this arrangement is limited to wet pipe systems. Typically, the end sprinkler fitting on a branch line is plugged as shown in Figures 3 through 11. The DS-1 Sprin- klers cannot be installed into an elbow fitting. For wet pipe systems, the sprinkler drop may be installed as shown in Fig- ure 12. The configuration in Figure 12 may only be used where the sprinkler fitting and water filled pipe above the sprinkler fitting is not subject to freez- ing and where the length of the DS-1 Sprinkler has the minimum exposure length per Figure 14. For wet pipe systems, the DS-1 Sprin- klers may also be installed in the fol- lowing Tyco® CPVC fittings: (P/N 80145) 1" x 1" NPT Female Adapter or (P/N 80249) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee. For dry pipe systems, only use the side outlet of maximum 2-1/2 inch size TFP500 Page 5 of 8 reducing tee's when locating the DS- 1 Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 13 to assure complete drainage of water from above the DS-1 Sprinklers and the branch line. NOTE Do not install the Series DS-1 into any other type fitting without first consult- ing the Technical Services Depart- ment. Failure to use the appropriate fitting may result in: failure of the sprin- kler to properly operate due to forma- tion of ice over the inlet Plug or bind- ing of the inlet Plug; or, insufficient engagement of the inlet pipe threads with consequent leakage. Branch, cross, and feedmain piping connected to Dry Sprinklers and sub- ject to freezing temperatures must be pitched for drainage in accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems. When Dry Sprinklers are to be used in wet pipe sprinkler systems protect- ing areas subject to freezing tempera- tures (e.g., sprinkler drops into freez- ers), consideration must be given to the appropriate length of the sprinkler that will prevent freezing of the water in the connecting pipes due to conduc- tion. When the temperature surround- ing the wet pipe sprinkler system is maintained at a minimum temperature of 40°F/40C, the following are the mini- mum recommended lengths between the face of the sprinkler fitting and the outside surface of the protected area (i.e., length exposed to minimum am- bient of 40°F/4°C - Ref. Figure 14): 12 inches (300 mm) when the tem- perature within the protected area is -20°F/-29°C 18 inches (450 mm) when the tem- perature within the protected area is -40°F/-40°C 24 inches (600 mm) when the tem- perature within the protected area is -60°F/-510C For protected area temperatures be- tween those given above, the minimum recommended length from the face of the fitting to the outside of the protect- ed area may be determined by interpo- lating between the indicated values. The 2007 edition of NFPA 13, Sec- tion 8.4.10.2 requires that dry sprin- klers connected to wet pipe sprinkler systems protecting insulated freezer structures have the clearance space around the sprinkler barrel be sealed. The use of the Model DSB-2 Dry Sprinkler Boot described in Technical Data Sheet TFP591, and illustrated in Figures 15 and 16, will meet the intent of NFPA 13. TO WET SIDE SYSTEM OUTLET PLUGGED HEATED AREA 1 INCH DSB-2 NPT TEE INTENDED (SEE DESIGN FOR FREEZER CRITERIA STRUCTURES SECTION) FIGURE 12, SPRINKLER FITTING IN HEATED AREA RUN OUTLET PLUGGED ! CRITERIA if INCH N PT TEE TO DRY (SEE DESIGN AREA SECTION) SUBJECT DSB-2 INTENDED TO FOR FREEZER FREEZING A STRUCTURES FIGURE 13, SPRINKLER FITTING IN UNHEATED AREA FACE OF - SPRINKLER FITTING HEATED EXPOSURE AREA LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES FIGURE 14, EXPOSURE LENGTH STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) DSB-2 BOOT ADHESIVE 1-3/4 DIA. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER 1-3/4 DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE DSB-2 BOOT STRAP TIES DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT) FIGURE 16 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER Page 6 of 8 TFP500 Installation The Series DS-1 Dry Type Sprinklers must be installed in accordance with the following instructions: NOTES The Series DS-1 must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1350F/570C rating to 1/8 inch (3,2 mm) for the 360°F/182°C rating. A 1 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 20 to 30 ft. lbs. (26,8 to 40,2 Nm). Higher levels of torque may dis- tort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. Pendent sprinklers must be installed only in the pendent position, and upright sprinklers must be in- stalled only in the upright position. The deflector of a pendent or upright sprin- kler is to be parallel to the ceiling. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpen- dicular to the back wall and parallel to the ceiling. The word "TOP" on the De- flector is to face towards the ceiling. Step 2. With pipe thread sealant ap- plied to the inlet threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler by wrenching on the Casing with a pipe wrench whenever the casing is readily accessible. Otherwise, use a W-Type 7 Sprinkler Wrench (Ref. Figure 2). The wrench recess of the W-Type 7 is to be applied to the sprinkler wrench flats (Ref. Figure 2). Step 4. After the ceiling/wall has been installed/finished, slide on the outer- piece of the Escutcheon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. In the case of the outer piece of the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling), and then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The Tycoll Series DS-1 Dry Type Sprin- klers must be maintained and ser- viced in accordance with the following instructions: NOTES Absence of the outer piece of an es- cutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tems must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evi- dence of leakage from the Vent Hole is an indication that there may be weep- age past the Inlet seal and that the sprinkler needs to be removed for de- termining the cause of leakage (e.g. an improper installation or an ice plug). The fire protection system control valve must be closed and the system drained before removing the sprinkler. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be com- pletely cleaned by wiping the sprin- kler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. The installing contrac- tor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. 1FP500 Page 7 of 8 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or imrDlied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Dry Sprinklers: Contact your local distributor for availability, and please specify the following: 1. Sprinkler. Model/SIN. Standard Response, Standard Coverage, Dry Type Sprinkler Deflector Style. 5.6 K-factor. Order Length. Dry Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 11, as applicable. After the mea- surement is taken, round it to the nearest 1/4 inch increment. Inlet Connection (1 Inch NPT or ISO 7-Ri) Temperature Rating. Sprinkler Finish. Escutcheon Style and Finish, as applicable. Part Number from Table B. (Part numbers are for 1 inch NPT stan- dard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description.) 2. W-Type 7 Sprinkler Wrench. Refer to the Price List for complete listing of Part Numbers. Model DSB-2: Specify: Model DSB-2 Dry Sprinkler Boot*, P/N 63-000-0-002. * Includes one Boot, two Strap Ties, and 1/3 oz. of Adhesive (quantity of adhesive is sufficient for installing one Boot) TFP500 ORDER LENGTH (1) (EXAMPLES) I 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00" 96 Pendent w/ Standard TY3255 Escutcheon (1" NPT) (Fig. 5) 93 Pendent w/ Deep TY3255 Escutcheon (1" NPT) (Fig. 6) 97 Pendent w/ Std. Recessed TY3255 Escutcheon (1" NPT) (Fig. 3) 92 Pendent w/o Escutcheon TY3255 (1" NPT) (Fig. 7) 1 NATURAL BRASS WHITE 4 WHITE POLYESTER WHITE 9 CHROME PLATED CHROME 0 CHROME PLATED WHITE 3 WHITE (RAL9010)* WHITE (RAL9010)* 2 NATURAL BRASS BRASS PLATED Page 8 of 8 P/N 60- XXX- X- XXX SPRINKLER ESCUTCHEON MODEL/SIN FINISH FINISH (2) 94 Sidewall wl Standard TY3355 Escutcheon (1" NPT) (Fig. 9) 53 Sidewall wl Deep TY3355 Escutcheon (1" NPT) (Fig. 10) 54 Sidewall w/o TY3355 - Escutcheon (1" NPT) (Fig. 11) II 98 Upright w/o Escutcheon I TY3155 - (1"NPT) (Fig. 8) TEMPERATURE RATING (3) 135F/57C 155F/68C 175F/79C 200F/93C 286F/141C 5 360F/182C NOTES Dry Type Sprinklers are furnished based upon Order Length" as measured per Figures 3 through 11, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. Escutcheon Finish applies to sprinklers provided with escutcheons. 286F/141C and 360/182C temperature ratings apply to non-recessed sprinkler assemblies. * Eastern Hemisphere sales only. TABLE B PART NUMBER SELECTION SERIES DS-I, STANDARD RESPONSE, STANDARD COVERAGE, DRY TYPE SPRINKLERS (Use Prefix "I" for ISO 7-RI Connection, e.g., 1-60-961-1-180) © 2007-2008 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446